WorldWideScience

Sample records for monoxide absorbing liquid

  1. Liquid Hydrogen Absorber for MICE

    Energy Technology Data Exchange (ETDEWEB)

    Ishimoto, S.; Suzuki, S.; Yoshida, M.; Green, Michael A.; Kuno, Y.; Lau, Wing

    2010-05-30

    Liquid hydrogen absorbers for the Muon Ionization Cooling Experiment (MICE) have been developed, and the first absorber has been tested at KEK. In the preliminary test at KEK we have successfully filled the absorber with {approx}2 liters of liquid hydrogen. The measured hydrogen condensation speed was 2.5 liters/day at 1.0 bar. No hydrogen leakage to vacuum was found between 300 K and 20 K. The MICE experiment includes three AFC (absorber focusing coil) modules, each containing a 21 liter liquid hydrogen absorber made of aluminum. The AFC module has safety windows to separate its vacuum from that of neighboring modules. Liquid hydrogen is supplied from a cryocooler with cooling power 1.5 W at 4.2 K. The first absorber will be assembled in the AFC module and installed in MICE at RAL.

  2. Comments on liquid hydrogen absorbers for MICE

    Energy Technology Data Exchange (ETDEWEB)

    Green, Michael A.

    2003-02-01

    This report describes the heat transfer problems associatedwith a liquid hydrogen absorber for the MICE experiment. This reportdescribes a technique for modeling heat transfer from the outside world,to the abosrber case and in its vacuum vessel, to the hydrogen and theninto helium gas at 14 K. Also presented are the equation for freeconvection cooling of the liquid hydrogen in the absorber.

  3. Liquid neutron absorber alternatives for the MPTRR

    Energy Technology Data Exchange (ETDEWEB)

    Jatuff, F.E.; Villarino, E.A. [INVAP S.E., S.C. de Bariloche (Argentina)

    1995-12-31

    The Multi-Purpose Type Research Reactor (MPTRR) control and first shutdown systems consist of six control plates of a Ag-In-Cd alloy. The second shutdown system is given by a liquid neutron absorber, a solution of boric acid, filling the inside of the chimney separating the core from the reflectors. The chimney is composed of four sides (four independent systems), each of them formed by two Zircaloy walls of 0.6 cm, and the empty central space inside (1.8 cm) filled with pure nitrogen during normal operation. The licensing criterion for the second shutdown system (the chimney, for brevity) requires a reactivity worth of {approximately}5000 pcm. The purpose of the work is the analysis of alternative liquid absorbers and the maximum reactivity worth reachable by the second shut-down system.

  4. Magnetically rotational reactor for absorbing benzene emissions by ionic liquids

    Institute of Scientific and Technical Information of China (English)

    Yangyang; Jiang; Chen; Guo; Huizhou; Liu

    2007-01-01

    A magnetically rotational reactor (MRR) has been developed and used in absorbing benzene emissions. The MRR has a permanent magnet core and uses magnetic ionic liquid [bmim]FeCl4 as absorbent. Benzene emissions were carried by N2 into the MRR and were absorbed by the magnetic ionic liquid. The rotation of the permanent magnet core provided impetus for the agitation of the magnetic ionic liquid, enhancing mass transfer and making benzene better dispersed in the absorbent. 0.68 g benzene emissions could be absorbed by a gram of [bmim]FeCl4, 0.27 and 0.40 g/ghigher than that by [bmim]PF6 and [bmim]BF4, respectively. The absorption rate increased with increasing rotation rate of the permanent magnet.

  5. Stretchable Metamaterial Absorber Using Liquid Metal-Filled Polydimethylsiloxane (PDMS

    Directory of Open Access Journals (Sweden)

    Kyeongseob Kim

    2016-04-01

    Full Text Available A stretchable metamaterial absorber is proposed in this study. The stretchability was achieved by liquid metal and polydimethylsiloxane (PDMS. To inject liquid metal, microfluidic channels were fabricated using PDMS powers and microfluidic-channel frames, which were built using a three-dimensional printer. A top conductive pattern and ground plane were designed after considering the easy injection of liquid metal. The proposed metamaterial absorber comprises three layers of PDMS substrate. The top layer is for the top conductive pattern, and the bottom layer is for the meandered ground plane. Flat PDMS layers were inserted between the top and bottom PDMS layers. The measured absorptivity of the fabricated absorber was 97.8% at 18.5 GHz, and the absorption frequency increased from 18.5 to 18.65 GHz as the absorber was stretched from its original length (5.2 cm to 6.4 cm.

  6. Wideband-Switchable Metamaterial Absorber Using Injected Liquid Metal

    Science.gov (United States)

    Kim, Hyung Ki; Lee, Dongju; Lim, Sungjoon

    2016-01-01

    Metamaterial absorbers can provide good solutions for radar-cross-section (RCS) reduction. In spite of their attractive features of thinness, lightness, and low cost, resonant metamaterial absorbers have a drawback of narrow bandwidth. For practical radar applications, wideband absorbers are necessary. In this paper, we propose a wideband-switchable metamaterial absorber using liquid metal. In order to reduce RCS both for X-band and C-band, the switchable Jerusalem cross (JC) resonator is introduced. The JC resonator consists of slotted circular rings, chip resistors, and microfluidic channels. The JC resonator is etched on a flexible printed circuit board (FPCB), and the microfluidic channels are laser-etched on a polydimethylsiloxane (PDMS) material. The proposed absorber can switch the absorption frequency band by injecting a liquid metal alloy into the channels. The performance of the absorber was demonstrated through full-wave simulation and through measurements employing prototypes. The experimental results showed absorption ratios of over 90% from 7.43 GHz to 14.34 GHz, and from 5.62 GHz to 7.3 GHz, with empty channels and liquid metal-filled channels, respectively. Therefore, the absorption band was successfully switched between the C-band (4–8 GHz) and the X-band (8–12 GHz) by injecting liquid metal eutectic gallium indium alloy (EGaIn) into the channels. PMID:27546310

  7. Methods for applying microchannels to separate methane using liquid absorbents, especially ionic liquid absorbents from a mixture comprising methane and nitrogen

    Science.gov (United States)

    Tonkovich, Anna Lee Y.; Litt, Robert D.; Dongming, Qiu; Silva, Laura J.; Lamont, Micheal Jay; Fanelli, Maddalena; Simmons, Wayne W.; Perry, Steven

    2011-10-04

    Methods of using microchannel separation systems including absorbents to improve thermal efficiency and reduce parasitic power loss. Energy is typically added to desorb methane and then energy or heat is removed to absorb methane using a working solution. The working solution or absorbent may comprise an ionic liquid, or other fluids that demonstrate a difference in affinity between methane and nitrogen in a solution.

  8. Modeling of Liquid Film along Absorber Cylinders in an Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Yamanaka, Tomofumi; Nagamoto, Wataru; Sugiyama, Takahide

    A two-dimensional liquid film model of LiBr solution falling along absorber cylinders has been studied to obtain boundary conditions for computing vapor flow in the absorber-evaporator of an absorption chiller. The model was established based on the assumptions that LiBr concentration and temperature profiles in the liquid film obey the third order polynomial expressions. It was indicated that mass flux and absorbed heat on the liquid surface can be calculated with simple numerical computations on the present analytical model. The overall heat transfer coefficient and total absorbed mass per second calculated with the present liquid film model was compared with experimental data for validation. The results calculated with the present model showed good agreement with the experimental data. Then, it was concluded the present model was useful enough for determining surface conditions on the LiBr liquid film around absorber cylinders.

  9. Terahertz saturable absorbers from liquid phase exfoliation of graphite

    Science.gov (United States)

    Bianchi, Vezio; Carey, Tian; Viti, Leonardo; Li, Lianhe; Linfield, Edmund H.; Davies, A. Giles; Tredicucci, Alessandro; Yoon, Duhee; Karagiannidis, Panagiotis G.; Lombardi, Lucia; Tomarchio, Flavia; Ferrari, Andrea C.; Torrisi, Felice; Vitiello, Miriam S.

    2017-06-01

    Saturable absorbers (SA) operating at terahertz (THz) frequencies can open new frontiers in the development of passively mode-locked THz micro-sources. Here we report the fabrication of THz SAs by transfer coating and inkjet printing single and few-layer graphene films prepared by liquid phase exfoliation of graphite. Open-aperture z-scan measurements with a 3.5 THz quantum cascade laser show a transparency modulation ~80%, almost one order of magnitude larger than that reported to date at THz frequencies. Fourier-transform infrared spectroscopy provides evidence of intraband-controlled absorption bleaching. These results pave the way to the integration of graphene-based SA with electrically pumped THz semiconductor micro-sources, with prospects for applications where excitation of specific transitions on short time scales is essential, such as time-of-flight tomography, coherent manipulation of quantum systems, time-resolved spectroscopy of gases, complex molecules and cold samples and ultra-high speed communications, providing unprecedented compactness and resolution.

  10. An absorbent for an application to a package for a liquid radioactive isotope for medical usage

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K.S.; Lim, S.P.; Lee, J.C.; Seo, K.S.; Han, H.S. [Korea Atomic Energy Research Inst., Daejeon (Korea)

    2004-07-01

    A radioactive isotope has to be safely transport from the producing center to the consuming center. The shipping package to safely transport the radioactive isotope should be able to withstand the prescribed conditions by law. In the field of nuclear medicine, the radioactive isotope is used in a liquid or capsule form. A Type A package, which is to transport liquid radioactive materials, shall be provided with a containment system composed of primary inner and secondary outer containment components or shall be provided with sufficient absorbent material to absorb twice the volume of the liquid contents. Hospitals prefer to use not only convenient but also re-usable packages. To apply an absorbent material to the Type A package, that is to transport liquid radioactive isotope, the free absorbency of the absorbents was estimated. In the case of a liquid with NaOH 0.4%, the free absorbency of the melanine form was the most superior at 91 g/g. In the case of a liquid with Na 0.9%, the free absorbency of the melanine form was the most excellent at 88 g/g also.

  11. Liquid absorbent solutions for separating nitrogen from natural gas

    Science.gov (United States)

    Friesen, Dwayne T.; Babcock, Walter C.; Edlund, David J.; Lyon, David K.; Miller, Warren K.

    2000-01-01

    Nitrogen-absorbing and -desorbing compositions, novel ligands and transition metal complexes, and methods of using the same, which are useful for the selective separation of nitrogen from other gases, especially natural gas.

  12. Separation of Flue Gas Components by SILP (Supported Ionic Liquid-Phase) Absorbers

    DEFF Research Database (Denmark)

    Thomassen, P.; Kunov-Kruse, Andreas Jonas; Mossin, Susanne L.

    2013-01-01

    -Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow processes for flue gas cleaning......Reversible absorption of the flue gas components CO2, NO, NO2 and SO2 has been tested for different ionic liquids (ILs) at different temperatures and flue gas compositions where porous, high surface area carriers have been applied as supports for the ionic liquids to obtain Supported Ionic Liquid....... The results show that CO2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperature, pressure and gas concentration. © 2012...

  13. Equation of state of initially liquid carbon monoxide and nitrogen mixture

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The modified liquid perturbation variational theory and the improved vdW-1f model were applied to calculating the equation of the state of liquid CO-N2 mixture with the ratio of 1:1, 4:1 and 1:4, respectively, in the shock pressure range of 9-49 GPa. It was shown that the calculated result for CO-N2 mixture with the ratio of 1:1 is well consistent with the earlier experimental data. The thermodynamics equilibrium, chemical equilibrium and phase equilibrium were all considered in detail. It was found that Hugoniot of liquid CO-N2 mixture is moderately softened in the pressure range of 20-30 GPa and 30-49 GPa for different initial proportions, and that the Hugoniot is more softened in the latter pressure range, which means that the structural phase transition occurs near 20 GPa and 30 GPa. Since the shock pro-ductions may absorb a plenty of systematic energy, the shock temperature and pressure decline compared with the case of no chemical reaction. Pressures and temperatures increase gradually with the increase in the mole fraction of nitrogen composition. The results for the 1:1 CO-N2 mixture lie in the middle of two others. Therefore, it was shown that the modified Lorentz-Berthelor rule used in the scheme is effective to study shock-compression properties of liquid CO-N2 mixture under high temperatures and high pressures.

  14. Equation of state of initially liquid carbon monoxide and nitrogen mixture

    Institute of Scientific and Technical Information of China (English)

    YANG JinWen; SUN Dong; SUN Yue; SHI ShangChun

    2008-01-01

    Academy of Engineering Physics,Mianyang 621900,ChinaThe modified liquid perturbation variational theory and the improved vdW-1f model were applied to calculating the equation of the state of liquid CO-N2 mixture with the ratio of 1:1,4:1 and 1:4,respectively,in the shock pressure range of 9-49 Gpa.It was shown that the calculated result for CO-N2 mixture with the ratio of 1:1 is well consistent with the earlier experimental data.The thermodynamics equilibrium,chemical equilibrium and phase equilibrium were all considered in detail.It was found that Hugoniot of liquid CO-N2 mixture is moderately softened in the pressure range of 20-30 Gpa and 30-49 Gpa for different initial proportions,and that the Hugoniot is more softened in the latter pressure range,which means that the structural phase transition occurs near 20 Gpa and 30 Gpa.Since the shock pro-ductions may absorb a plenty of systematic energy,the shock temperature and pressure decline compared with the case of no chemical reaction.Pressures and temperatures increase gradually with the increase in the mole fraction of nitrogen composition.The results for the 1:1 CO-N2 mixture lie in the middle of two others.Therefore,it was shown that the modified Lorentz-Berthelor rule used in the scheme is effective to study shock-compression properties of liquid CO-N2 mixture under high temperatures and high pressures.

  15. Polarity and Nonpolarity of Ionic Liquids Viewed from the Rotational Dynamics of Carbon Monoxide.

    Science.gov (United States)

    Yasaka, Y; Kimura, Y

    2015-12-17

    The rotational dynamics of carbon monoxide (CO) in a molten salt, ionic liquids (ILs), and alkanes were investigated by (17)O NMR T1 measurements using labeled C(17)O. The molten salt and the studied ILs have the bis(trifluoromethanesulfonyl)imide anion ([NTf2](-)) in common. In hexane near room temperature, the rotational relaxation times are close to the values predicted from the slip boundary condition in the Stokes-Einstein-Debye (SED) theory. However, in contradiction to the theoretical prediction, the rotational relaxation times decrease as the value of η/T increases, where η and T are the viscosity and absolute temperature, respectively. In other alkanes and ILs used in this study, the rotational relaxation times are much faster than those predicted by SED, and show a unique dependence on the number of alkyl carbons. For the same value of η/T, the CO rotational relaxation times in ILs composed of short-alkyl-chain-length imidazolium cations (1-ethyl-3-methylimidazolium and 1-butyl-3-methylimidazolium) are close to those for a molten salt (Cs[NTf2]). On the other hand, the rotational relaxation times in ILs composed of long-chain-length imidazolium (1-methyl-3-octylimidazolium) and phosphonium (tributylmethylphosphonium and tetraoctylphosphonium) cations are much shorter than the SED predictions. This deviation from theory increases as the alkyl chain length increases. We also found that the rotational relaxation times in dodecane and squalane are similar to those in ILs with a similar number of alkyl carbons. These results are discussed in terms of heterogeneous solvation and in comparison with the translational diffusion of CO in ILs.

  16. The containment and an absorbent evaluation for a package for a liquid radioactive isotope

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K. S.; Lee, J. C.; Kim, D. H.; Hwang, C. S.; Kim, H. J.; Seo, K. S

    2005-03-01

    Radioactive isotopes must be safely transported from the production centre to the point of use. The shipping package to safely transport radioactive isotopes should be able to withstand the conditions prescribed by law. A type a package, which is used to transport liquid radioactive materials, should have a containment system comprising a primary inner and a secondary outer containment or it should be provided with a sufficiently absorbent material to absorb twice the volume of the liquid contents. Accordingly, an absorbent material for use in a Type A package to transport a liquid radioactive isotope was estimated. To estimate the integrity of containment, the leakage tests for a containment system for a Type A package for domestic and abroad expert were conducted.

  17. Capture of liquid hydrogen boiloff with metal hydride absorbers

    Science.gov (United States)

    Rosso, M. J.; Golben, P. M.

    1984-01-01

    A procedure which uses metal hydrides to capture some of this low pressure (,1 psig) hydrogen for subsequent reliquefaction is described. Of the five normally occurring sources of boil-off vapor the stream associated with the off-loading of liquid tankers during dewar refill was identified as the most cost effective and readily recoverable. The design, fabrication and testing of a proof-of-concept capture device, operating at a rate that is commensurate with the evolution of vapor by the target stream, is described. Liberation of the captured hydrogen gas at pressure .15 psig at normal temperatures (typical liquefier compressor suction pressure) are also demonstrated. A payback time of less than three years is projected.

  18. Melt Absorbability of Iron Ore Nuclei and Its Influence on Suitable Liquid Content of Sintered Body

    Science.gov (United States)

    Wu, Sheng-Li; Su, Bo; Qi, Yuan-Hong; Kou, Ming-Yin; Li, Yuan; Zhang, Wei-Li

    2017-10-01

    Sinter quasi-particles consist of nuclei particles and adhering fines. Therefore, reaction properties of the nuclei ore will ultimately affect the bonding strength of the sintered body. In this study, micro-sintering tests were conducted to explore the melt absorbability of nuclei ore and its effect on the suitable liquid content of the sintered body. The results showed that the melt absorbability is negatively correlated with the lowest assimilation temperature, and the most important mineralogy factor influencing melt absorbability is iron mineral type. The reaction behaviors of melts containing SiO2 or Al2O3 substrates are different, and the reaction process of the melt containing SiO2 is more complicated. In addition, the bonding strength of the sintered body is collectively determined by the liquid phase fluidity of adhering fines and the assimilability of nuclei ore. The high melt absorbability has an adverse effect on bonding strength, and it requires adhering fines to provide more primary melts to meet the requirements for sintered body bonding strength. In the condition with the same liquid content, for nuclei ore with stronger melt absorbability, an appropriate increase in the adhering fines ratio and reduction in segregation basicity are more conducive to improving the bonding strength.

  19. Study of Solid-Liquid Ratio of Fly Ash Geopolymer as Water Absorbent Material

    Directory of Open Access Journals (Sweden)

    Angga Prasetya Fandi

    2017-01-01

    Full Text Available Geopolymer has been synthesized from fly ash to be applicated as water absorbent material. This research conducted to determine the ability of geopolymer to abrsop water by variation of solid – liquid ratio at optimum molarity of NaOH; 3 M. In this research, the synthesis of geopolymer was conducted at the variation of solid-liquid ratio; 60:40, 65:35, 70:30, and 75:25. Result of the treatment were characterized by XRD and SEM to compare the geopolymer structure. Water absorption capacity was measured by immersing the geopolymer specimens in water for 24 hours. Based on the result, solid – liquid ratio with maximum water absorbed was 70:30 with 13,04 wt%.

  20. Liquid carbon dioxide absorbents, methods of using the same, and related systems

    Science.gov (United States)

    O'Brien, Michael Joseph; Perry, Robert James; Lam, Tunchiao Hubert; Soloveichik, Grigorii Lev; Kniajanski, Sergei; Lewis, Larry Neil; Rubinsztajn, Malgorzata Iwona; Hancu, Dan

    2016-09-13

    A carbon dioxide absorbent composition is described, including (i) a liquid, nonaqueous silicon-based material, functionalized with one or more groups that either reversibly react with CO.sub.2 or have a high-affinity for CO.sub.2; and (ii) a hydroxy-containing solvent that is capable of dissolving both the silicon-based material and a reaction product of the silicon-based material and CO.sub.2. The absorbent may be utilized in methods to reduce carbon dioxide in an exhaust gas, and finds particular utility in power plants.

  1. Robust sensor for turbidity measurement from light scattering and absorbing liquids.

    Science.gov (United States)

    Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik

    2009-12-01

    Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.

  2. CO2 capture technologies: current status and new directions using supported ionic liquid phase (SILP) absorbers

    DEFF Research Database (Denmark)

    Kolding, Helene; Fehrmann, Rasmus; Riisager, Anders

    2012-01-01

    Current state-of-the-art techniques for CO2 capture are presented and discussed. Post-combustion capture of CO2 by absorption is the technology most easily retrofitted to existing installations, but at present this is not economically viable to install and run. Using ionic liquids instead...... candidate for CO2 absorption using SILP technology. Thus a solid SILP absorber comprised of 40 wt% [N6666][Pro] loaded on precalcined silica quantitatively takes up about 1.2 mole CO2 per mole of ionic liquid in consecutive absorption-desorption cycles in a flow-experiment performed with 0.09 bar of CO2 (9......% CO2 in He)....

  3. CO2 capture technologies: current status and new directions using supported ionic liquid phase (SILP) absorbers

    DEFF Research Database (Denmark)

    Kolding, Helene; Fehrmann, Rasmus; Riisager, Anders

    2012-01-01

    Current state-of-the-art techniques for CO2 capture are presented and discussed. Post-combustion capture of CO2 by absorption is the technology most easily retrofitted to existing installations, but at present this is not economically viable to install and run. Using ionic liquids instead...... candidate for CO2 absorption using SILP technology. Thus a solid SILP absorber comprised of 40 wt% [N6666][Pro] loaded on precalcined silica quantitatively takes up about 1.2 mole CO2 per mole of ionic liquid in consecutive absorption-desorption cycles in a flow-experiment performed with 0.09 bar of CO2 (9......% CO2 in He)....

  4. Laser ablation of absorbing liquids under transparent cover: acoustical and optical monitoring

    Science.gov (United States)

    Samokhin, A. A.; Il'ichev, N. N.; Pivovarov, P. A.; Sidorin, A. V.

    2016-06-01

    Phase transition induced with infrared (λ = 2920 nm and λ = 2940 nm) nanosecond laser pulses in strongly absorbing liquids (water, ethanol) under transparent solid cover is investigated with the help of acoustical and optical monitoring. LiNbO3 transducer is used for registration of pressure pulses generated in irradiated liquids. Optical signals due to scattering and specular reflection of probing optical beams are explored with the schemes involving total internal reflection and interference effects. Combination of these two optical diagnostic methods permits for the first time to show that irradiation of covered liquids leads to vapor cavity formation which is divided from the cover with thin (submicron) liquid film despite the fact that radiation intensity maximum is located just at the liquid-plate boundary. The cavity formation is due to explosive boiling which occurs when the superheated liquid reaches its superheating limit in near critical region. After the first acoustical signal, the second signal is observed with several hundreds microseconds time delay which is caused by the vapor cavity collapse. Some results of optical and acoustical diagnostics in the case of free liquid surface are also presented.

  5. Design and Evaluation of Ionic Liquids as Novel CO2 Absorbents

    Energy Technology Data Exchange (ETDEWEB)

    Edward Maginn

    2007-07-15

    This is the final report for project DE-FG26-04NT42122 'Design and Evaluation of Ionic Liquids as Novel CO{sub 2} Absorbents'. The objective of this 'breakthrough concepts' project was to investigate the feasibility of using ionic liquids for post-combustion CO{sub 2} capture and obtain a fundamental understanding of the solubility of CO{sub 2} and other components present in flue gas in ionic liquids. Our plan was to obtain information on how composition and structure of ionic liquid molecules affected solubility and other important physical properties via two major efforts: synthesis and experimental measurements and molecular simulation. We also planned to perform preliminary systems modeling study to assess the economic viability of a process based on ionic liquids. We accomplished all the milestones and tasks specified in the original proposal. Specifically, we carried out extensive quantum and classical atomistic-level simulations of a range of ionic liquids. These calculations provided detailed information on how the chemical composition of ionic liquids affects physical properties. We also learned important factors that govern CO{sub 2} solubility. Using this information, we synthesized or acquired 33 new ionic liquids. Many of these had never been made before. We carried out preliminary tests on all of these compounds, and more extensive tests on those that looked most promising for CO{sub 2} capture. We measured CO{sub 2} solubility in ten of these ionic liquids. Through our efforts, we developed an ionic liquid that has a CO{sub 2} solubility 2.6 times greater than the 'best' ionic liquid available to us at the start of the project. Moreover, we demonstrated that SO{sub 2} is also extremely soluble in ionic liquids, opening up the possibility of using ionic liquids to remove both SO{sub 2} and CO{sub 2} from flue gas. In collaboration with Trimeric Inc., a preliminary systems analysis was conducted and the results used to

  6. Vibration Mitigation in Partially Liquid-Filled Vessel using Passive Energy Absorbers

    CERN Document Server

    Farid, Maor; Gendelman, O V

    2016-01-01

    This paper treats possible solutions for vibration mitigation in reduced-order model of partially-filled liquid tank under impulsive forcing. Such excitation may lead to hydraulic impacts applied on the tank inner walls. Finite stiffness of the tank walls is taken into account. We explore both linear (Tuned Mass Damper) and nonlinear (Nonlinear Energy Sink) passive vibration absorbers; mitigation performances are examined numerically. The liquid sloshing mass is modeled by equivalent massspring-dashpot system, which can both perform small-amplitude linear oscillations and impact the vessel walls. We use parameters of the equivalent mass-spring-dashpot system for well-explored case of cylindrical tanks. The hydraulic impacts are modeled by high-power potential and dissipation functions. Critical location in the tank structure is determined and expression of the corresponding local mechanical stress is derived. We use finite-elemet approach to assess the natural frequencies for specific system parameters and to...

  7. Laser-induced back-side etching with liquid and the solid hydrocarbon absorber films of different thicknesses

    Science.gov (United States)

    Ehrhardt, M.; Lorenz, P.; Yunxiang, P.; Bayer, L.; Han, B.; Zimmer, K.

    2017-04-01

    Laser-induced backside wet and dry etching (LIBWE and LIBDE) are methods for high-quality surface patterning of transparent dielectrics that making use of an additional absorber material attached to the rear side that is ablated in a confined configuration. Due to the manifold of the involved processes, the mechanism of the etching process and the parameter influence on the material removal process are multifaceted and not fully understood yet. In the present paper, we investigate the influence of the confinement to the backside etching process by studying the impact of the thickness of the attached liquid or solid absorber within a range of 12-125 and 0.2-11.7 μm, respectively. It was found that for the liquid and solid absorbers, the etching rate increases with the thickness of the absorber layer and saturates exceeding a certain value, which depends on the used laser fluence. Moreover, the incubation of etching depends on the absorber thickness. The comparison of the etching results of a similar thickness of the liquid and the solid absorber layers shows that the phase of the absorber (liquid or solid) does not influence the back-side etching process. Time-resolved shadowgraph images of the process indicate that with higher absorber layer thickness, the interaction time and strength of the laser-induced processes at the sample surface increase. The results suggest that confinement of the rear side attached absorber ablation influences the impact of the laser-induced secondary processes to the strength of the material modifications and, therefore, the etching rate.

  8. Optical absorbance measurements of opaque liquids by pulsed laser photoacoustic spectroscopy.

    Science.gov (United States)

    Schmid, Thomas; Panne, Ulrich; Niessner, Reinhard; Haisch, Christoph

    2009-03-15

    In many relevant industrial applications, UV-vis online process monitoring is hampered by light scattering and opacity of the samples, whereas diluted and filtered samples are rarely available. Pulsed laser photoacoustic (PA) spectroscopy allows the measurement of both high and low absorptions without any need for sample preparation. An optimized detection geometry for absorption measurements in opaque liquids is described. The proposed PA sensor was realized by using two orthogonal detectors based on piezoelectric poly(vinylidene fluoride) (PVDF). Laser-induced pressure waves were sensed perpendicularly to (side-on mode) and along the axis of the laser beam (forward mode). Pressure waves generated by a single laser pulse, optical transmission and absorption, as well as the speed of sound in liquid samples were determined simultaneously using time-resolved detection. Evaluation of the PA signal permits the determination of absorption coefficients ranging from 0.1 to 1000 cm(-1). The influence of absorbing or scattering compounds on the signal was investigated in dye solutions and suspensions of TiO(2) particles.

  9. Soft and broadband infrared metamaterial absorber based on gold nanorod/liquid crystal hybrid with tunable total absorption

    Science.gov (United States)

    Su, Zhaoxian; Yin, Jianbo; Zhao, Xiaopeng

    2015-11-01

    We design a soft infrared metamaterial absorber based on gold nanorods dispersed in liquid crystal (LC) placed on a gold film and theoretically investigate its total absorption character. Because the nanorods align with the LC molecule, the gold nanorods/LC hybrid exhibits different permittivity as a function of tilt angle of LC. At a certain tilt angle, the absorber shows an omnidirectional total absorption effect. By changing the tilt angle of LC by an external electric field, the total absorption character can be adjusted. The total absorption character also depends on the concentration, geometric dimension of nanorods, and defect of nanorod arrangement in LC. When the LC contains different size of gold nanorods, a broadband absorption can be easily realized. The characteristics including flexibility, omnidirectional, broadband and tunablility make the infrared metamaterial absorber possess potential use in smart metamaterial devices.

  10. Bridging the terahertz near-field and far-field observations of liquid crystal based metamaterial absorbers

    Science.gov (United States)

    Wang, Lei; Ge, Shijun; Chen, Zhaoxian; Hu, Wei; Lu, Yanqing

    2016-09-01

    Metamaterial-based absorbers play a significant role in applications ranging from energy harvesting and thermal emitters to sensors and imaging devices. The middle dielectric layer of conventional metamaterial absorbers has always been solid. Researchers could not detect the near field distribution in this layer or utilize it effectively. Here, we use anisotropic liquid crystal as the dielectric layer to realize electrically fast tunable terahertz metamaterial absorbers. We demonstrate strong, position-dependent terahertz near-field enhancement with sub-wavelength resolution inside the metamaterial absorber. We measure the terahertz far-field absorption as the driving voltage increases. By combining experimental results with liquid crystal simulations, we verify the near-field distribution in the middle layer indirectly and bridge the near-field and far-field observations. Our work opens new opportunities for creating high-performance, fast, tunable, terahertz metamaterial devices that can be applied in biological imaging and sensing. Project supported by the National Basic Research Program of China (Grant No. 2012CB921803), the National Natural Science Foundation of China (Grants Nos. 61225026, 61490714, 11304151, and 61435008), the Natural Science Foundation of Jiangsu Province, China (Grant Nos. BK20150845 and 15KJB140004), the Open Foundation Project of National Laboratory of Solid State Microstructures, China (Grant No. M28003), and the Research Center of Optical Communications Engineering & Technology, Jiangsu Province, China.

  11. Evaluation of polyacrylonitrile (PAN) as a binding polymer for absorbers used to treat liquid radioactive wastes

    Energy Technology Data Exchange (ETDEWEB)

    Sebesta, F.; John, J.; Motl, A.; Stamberg, K. [Czech Technical University in Prague (Czech Republic). Dept. of Nuclear Chemistry

    1995-11-01

    The chemical and radiation stability of polyacrylonitrile (PAN) in the form of beads (B-PAN), similar to the beads of composite absorbers, and one selected composite absorber (ammonium molybdophosphate, the active component in PAN binder [AMP-PAN], a prospective candidate for the treatment of acidic wastes) were studied. Aqueous 1M HNO{sub 3} + 1M NaNO{sub 3}, 1M NaOH + 1M NaNO{sub 3}, and 1M NaOH were chosen as simulants of DOE acidic and alkaline wastes. In addition,radiation stability was determined indistilled water. The chemical stability of B-PAN and AMP-PAN beads was tested for a period up to one month of contact with the solution at ambient temperature. The radiation stability of the beads was checked in a radiation dose range 10{sup 3}--10{sup 6} Gy (10{sup 5}--10{sup 8} rads). In acidic solutions the stability of PAN binder was proved not to be limited by either chemical or radiation decomposition. PAN binder may thus be used for preparing composite absorbers for treatment of acid wastes from DOE facilities. The same conclusion is valid for alkaline solutions with pH up to 13. In highly alkaline solutions (concentration of NAOH higher than I M) and in the presence of NaNO{sub 3}, the stability of the tested polyacrylonitrile polymer was sufficient for applications not extending over 10 days. Cross-linking of the polymer caused by ionizing radiation was found to have a positive influence on chemical stability. This effect enables a longer period of applicability of PAN-based composite absorbers. Because of the high sorption rate achievable with PAN-based absorbers, the stability achieved is sufficient for most applications in the DOE complex. The chemical stability of binding polymer may also be further improved by testing another, more suitable type of polymer from the broad family of polyacrylonitrile polymers.

  12. Unusual solvatochromic absorbance probe behaviour within mixtures of poly(ethylene glycol)-400 + ionic liquid, [bmim][Tf2N

    Science.gov (United States)

    Ali, Anwar; Ali, Maroof; Malik, Nisar Ahmad; Uzair, Sahar

    2014-03-01

    The potentially green solvents made up of ionic liquids (ILs) and poly(ethylene glycols) may have wide range of the applications in many chemical and biochemical fields. In the present work, solvatochromic absorbance probe behaviour is used to assess the physicochemical properties of the mixtures composed of PEG-400 + IL, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, [bmim][Tf2N]. Lowest energy intramolecular charge-transfer absorbance maxima of a betaine dye, i.e., ETN , indicates the dipolarity/polarizability and/or hydrogen-bond donating (HBD) acidity of the [bmim][Tf2N] + PEG-400 mixtures to be even higher than that of neat [bmim][Tf2N], the solution component with higher dipolarity/polarizability and/or HBD acidity. Dipolarity/polarizability (π∗) obtained separately from the electronic absorbance response of probe N,N-diethyl-4-nitroaniline, and the HBD acidity (α) of PEG-400 + [bmim][Tf2N] mixtures are also observed to be anomalously high. A comparative study of the PEG + IL mixtures has also been done with PEG-400 + molecular organic solvents (protic polar [methanol], aprotic polar [N,N-dimethylformamide], and non polar, [benzene]) mixtures, but these mixtures do not show this type of unusual behaviour. A four-parameter simplified combined nearly ideal binary solvent/Redlich-Kister (CNIBS/R-K) equation is shown to satisfactorily predict the solvatochromic parameters within PEG-400 + different solvent mixtures.

  13. Passively Q-switched flashlamp pumped Nd:YAG laser using liquid graphene oxide as saturable absorber

    Science.gov (United States)

    Adnan, N. N.; Bidin, N.; Taib, N. A. M.; Haris, H.; Fakaruddin, M.; Hashim, A. M.; Krishnan, G.; Harun, S. W.

    2016-06-01

    The performance of passively Q-switched Nd:YAG laser operating at 1060 nm is demonstrated using liquid graphene oxide (GO) composite solution as saturable absorber for the first time. The Q-switched Nd:YAG laser is pumped by a xenon flashlamp. The GO was prepared using the simplified Hummer's method and then mixed with polyethylene oxide to form a composite solution. The Q-switched pulsed laser operates at wavelength of 1064.5 nm with a threshold pump energy of 33.64 J. The maximum output Q-switched laser energy of 41.6 mJ achieved at the maximum pump energy of 81 J. The corresponding pulse width is 98.67 ns.

  14. Carbon monoxide poisoning

    Science.gov (United States)

    ... and smokers. Carbon monoxide can harm a fetus (unborn baby still in the womb). Symptoms of carbon ... symptoms Outlook (Prognosis) Carbon monoxide poisoning can cause death. For those who survive, recovery is slow. How ...

  15. CARBON MONOXIDE TREATMENT GUIDELINES

    Directory of Open Access Journals (Sweden)

    Miran Brvar

    2014-02-01

    Full Text Available Carbon monoxide is the leading cause of unintentional poisoning-related death in Slovenia. It is an odorless, colorless gas that usually remains undetectable until exposures result in injury or death. Exposure to carbon monoxide is most commonly accompanied by headache, nausea, vomiting, dizziness, confusion, drowsiness, fatigue and collapse. Carbon monoxide poisoning management includes normobaric oxygen therapy. Hyperbaric-oxygen treatments reduce the risk of cognitive sequelae after carbon monoxide poisoning. 

  16. Study on oil absorbency of succinic anhydride modified banana cellulose in ionic liquid.

    Science.gov (United States)

    Shang, Wenting; Sheng, Zhanwu; Shen, Yixiao; Ai, Binling; Zheng, Lili; Yang, Jingsong; Xu, Zhimin

    2016-05-05

    Banana cellulose contained number of hydrophilic hydroxyl groups which were succinylated to be hydrophobic groups with high oil affinity. Succinic anhydride was used to modify banana cellulose in 1-allyl-3-methylimidazolium chloride ionic liquid in this study. The modified banana cellulose had a high oil absorption capacity. The effects of reaction time, temperature, and molar ratio of succinic anhydride to anhydroglucose on the degree of substitution of modified banana cellulose were evaluated. The optimal reaction condition was at a ratio of succinic anhydride and anhydroglucose 6:1 (m:m), reaction time 60min and temperature 90°C. The maximum degree of acylation reaction reached to 0.37. The characterization analysis of the modified banana cellulose was performed using X-ray diffractometer, Fourier transform infrared spectrometer, scanning electron microscopy and thermogravimetry. The oil absorption capacity and kinetics of the modified banana cellulose were evaluated at the modified cellulose dose (0.025-0.3g), initial oil amount (5-30g), and temperature (15-35°C) conditions. The maximum oil absorption capacity was 32.12g/g at the condition of the cellulose dose (0.05g), initial oil amount (25g) and temperature (15°C). The kinetics of oil absorption of the cellulose followed a pseudo-second-order model. The results of this study demonstrated that the modified banana cellulose could be used as an efficient bio-sorbent for oil adsorption.

  17. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... main content Languages 简体中文 English Bahasa Indonesia 한국어 Español ภาษาไทย Tiếng Việt Text Size: Decrease Font Increase ... Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as ...

  18. Absorbance and Photoluminescence of Si, Ge, and MoS{sub 2} Nanoparticles Studied by Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Provencio, P.P.; Samara, G.A.; Wilcoxon, J.P,

    1999-07-12

    The authors have successfully synthesized highly crystalline, size-selected indirect band-gap nanocrystals (NC) of Si, Ge and MoS{sub 2} in the size range 2-10 nm in inverse micelles and studied their optical absorption and photoluminescence (PL) properties using liquid chromatography. Room temperature, visible PL from these nanocrystals was demonstrated in the range 700-350 nm (1.8-3.5 eV). their experimental results are interpreted in terms of the corresponding electronic structure of the bulk materials and it is demonstrated that these nanocrystals retain bulk-like electronic character to sizes as small as 2 nm, but the absorbance energies are strongly blue-shifted by quantum confinement. The experimental results on Si-NCs are also compared to earlier work on Si clusters grown by other techniques and to the predictions of various model calculations. Currently, the wide variations in the theoretical predictions of the various models along with considerable uncertainties in experimental size determination for clusters less than 3-4 nm, make it difficult to select the best model.

  19. Preparation of CuGaSe{sub 2} absorber layers for thin film solar cells by annealing of efficiently electrodeposited Cu-Ga precursor layers from ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Steichen, M., E-mail: marc.steichen@uni.lu; Larsen, J.; Guetay, L.; Siebentritt, S.; Dale, P.J.

    2011-08-31

    CuGaSe{sub 2} absorber layers were prepared on molybdenum substrates by electrochemical codeposition of copper and gallium and subsequential annealing in selenium vapour. The electrodeposition was made from a deep eutectic based ionic liquid consisting of choline chloride/urea (Reline) with a plating efficiency of over 85%. The precursor film composition is controlled by the ratio of the copper to gallium fluxes under hydrodynamic conditions and by the applied deposition potential. X-ray diffraction reveals CuGa{sub 2} alloying during the electrodeposition and CuGaSe{sub 2} formation after annealing. Photoluminescence (PL) and photocurrent spectroscopy revealed the good opto-electronic properties of the CuGaSe{sub 2} absorber films. The absorber layers have been converted to full devices with the best device achieving 4.0 % solar conversion efficiency.

  20. Determination of Tetracyclines in Honey Using Liquid Chromatography with Ultraviolet Absorbance Detection and Residue Confirmation by Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LIU,Yan; XU,Jin-Zhong; DING,Tao; LI,Gong-Hai

    2007-01-01

    A determination method has been optimized and validated for the simultaneous analysis of tetracycline (TC),oxytetracycline (OTC), chlortetracycline (CTC) and doxycycline (DC) in honey. Tetracyclines (TCs) were removed from honey samples by chelation with metal ions bound to small Chelating Sepharose Fast Flow columns and eluted with Na2EDTA-Mcllvaine pH 4.0 buffers. Extracts were further cleaned up by Oasis HLB solid-phase extraction (SPE), while other solid-phase extraction cartridges were compared. Chromatographic separation was achieved using a polar end-capped C18 column with an isocratic mobile phase consisting of oxalic acid, acetonitrile,and methanol. LC with ultraviolet absorbance at 355 nm resulted in the quantitation of all four tetracycline residues from honey samples fortified at 15, 50, and 100 ng/g, with liner ranges for tetracyclines of 0.05 to 2 μg/mL. Mean recoveries for tetracyclines were greater than 50% with R.S.D. values less than 10% (n= 18). Detection limits of 5,5, 10, 10 ng/g for oxytetracycline, tetracycline, chlortetracycline and doxycycline, respectively and quantitation limits of 15 ng/g for all the four tetracyclines were determined. Direct confirmation of the four residues in honey (2-50 ng/g) was realized by liquid chromatography-tandem mass spectrometry (LC/MS/MS). The linear ranges of tetracyclines determined by LC/MS/MS were between 5 to 300 ng/mL, with the linear correlation coefficient r>0.995. The limits of detection of 1 to 2 ng/g were obtained for the analysis of the TCs in honey.

  1. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire Carbon Monoxide from Engine-Driven Generators and ... Engine-Driven Tools, 2004–2014 JANUARY 08, 2015 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2011 Annual Estimates View All ... Inside CPSC Accessibility ...

  2. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... CONSUMER PRODUCT SAFETY COMMISSION Search CPSC Search Menu Home Recalls Recall List CPSC Recall API Recall Lawsuits ... and Bans Report an Unsafe Product Consumers Businesses Home Safety Education Safety Education Centers Carbon Monoxide Information ...

  3. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ... 2011 Annual Estimates View All CO-Related Injury Statistics and Technical Reports Related Links Recalls Safety Education ...

  4. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide ... Related Links Recalls Safety Education Regulations, Laws & Standards Research & Statistics Business & Manufacturing Small Business Resources OnSafety Blogs ...

  5. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Community Outreach Resource Center Toy Recall Statistics CO Poster Contest Pool Safely Business & Manufacturing Business & Manufacturing Business ... Featured Resources CPSC announces winners of carbon monoxide poster contest Video View the blog Clues You Can ...

  6. Carbon Monoxide Information Center

    Science.gov (United States)

    ... and Criminal Penalties Federal Court Orders & Decisions Research & Statistics Research & Statistics Technical Reports Injury Statistics NEISS Injury Data ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ...

  7. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 Annual Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire ...

  8. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  9. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Import Safety International Recall Guidance Civil and Criminal Penalties Federal Court Orders & ... 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 ...

  10. Carbon Monoxide Nonattainment Areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies areas in the U.S. where air pollution levels have not met the National Ambient Air Quality Standards (NAAQS) for Carbon Monoxide and have...

  11. Carbon Monoxide Information Center

    Medline Plus

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  12. Moving beyond the limits of mass transport in liquid absorbent microfilms through the implementation of surface-induced vortices

    Energy Technology Data Exchange (ETDEWEB)

    Bigham, S; Yu, DZ; Chugh, D; Moghaddam, S

    2014-02-01

    The slow diffusion of an absorbate molecule into an absorbent often makes the absorption process a rate-limiting step in many applications. In cases involving an absorbate with a high heat of phase change, such as water absorption into a LiBr (lithium bromide) solution, the absorption rate is further slowed due to significant heating of the absorbent. Recently, it has been demonstrated that constraining a LiBr solution film by a hydrophobic porous structure enables manipulation of the solution flow thermohydraulic characteristics. Here, it is shown that mass transport mode in a constrained laminar solution flow can be changed from diffusive to advective. This change in mode is accomplished through stretching and folding the laminar streamlines within the solution film via the implementation of micro-scale features on the flow channel surface. The process induces vortices within the solution film, which continuously bring concentrated solution from the bottom and middle of the solution channel to its interface with the vapor phase, thus leading to a significant enhancement in the absorption rate. The detailed physics of the involved transport processes is elucidated using the LBM (Lattice Boltzmann Method). Published by Elsevier Ltd.

  13. Development and Application of Organic Liquid Absorbance Detector%有机液体吸光度检测仪的开发应用

    Institute of Scientific and Technical Information of China (English)

    张典成; 杨秉松

    2016-01-01

    湿法冶金生产工艺中,有机萃取是常见的工艺,生产过程中有机液体的颜色及色深(吸光度),是工艺指标性参数,但是对于有机液体的在线测量,因缺乏成熟的仪器,目前大多靠人眼目测和实验室比对的方式。我们以比尔-朗伯定律为理论依据,通过对有机液体吸光度变化与光电吸收关系的研究,开发了有机液体吸光度检测仪,并投入了现场应用,取得了良好的效果。%In wet⁃process metallurgy industry, organic extraction is a common technique. The color and color depth ( absor⁃bance) of organic liquid are process parameters of the production process, but the on⁃line measurement of the organic liq⁃uid, mainly depends on human visual inspection and laboratory comparison at present, due to the lack of maturity of the in⁃strument. Based on the Beer⁃Lambert law and study of relationship between organic liquid absorbance changes and photoe⁃lectric absorption, we developed the organic liquid absorbance detector has been developed and put into field application, and good results were achieved.

  14. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, P. Avilés, E-mail: paz.aviles@ciemat.es; Aubineau-Lanièce, I.; Lourenço, V.; Vermesse, D.; Cutarella, D. [CEA, LIST, Laboratoire National Henri Becquerel, 91191 Gif-sur-Yvette (France)

    2014-01-15

    Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a

  15. Study on separation of platinum group metals from high level liquid waste using macroporous (MOTDGA-TOA)/SiO{sub 2}-P silica-based absorbent

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tatsuya [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Aoba 6-6, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Japan Atomic Energy Agency, Tokai-mura Naka-gun, Ibarak319-1195 (Japan); Kim, Seong-Yun; Xu, Yuanlai; Hitomi, Keitaro [Cyclotron and Radioisotope Center, Tohoku University, Aoba 6-3, Aramaki, Aoba-ku, Sendai, Miyagi 980-8578 (Japan); Ishii, Keizo [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Aoba 6-6, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Nagaishi, Ryuji; Kimura, Takaumi [Japan Atomic Energy Agency, Tokai-mura Naka-gun, Ibarak319-1195 (Japan)

    2013-07-01

    The recovery of platinum group metals (PGMs) from high level liquid waste (HLLW) by macroporous silica-based adsorbent, (MOTDGA-TOA)/SiO{sub 2}-P has been developed by impregnating two extractants of N,N'-dimethyl-N,N'-di-n-octyl-thio-diglycolamide (MOTDGA) and tri-n-octylamine (TOA) into a silica/polymer composite support (SiO{sub 2}-P). The adsorption of Ru(III), Rh(III) and Pd(II) have been investigated in simulated HLLW by batch method. The adsorbent has shown good uptake property for Pd(II). In addition, the combined use of MOTDGA and TOA improved the adsorption of Ru(III) and Rh(III) better than the individual use of them. The usability of adsorbent in radiation fields was further confirmed by irradiation experiments. The adsorbent remained to have the uptake capability for PGMs over the absorbed dose of 100 kGy, corresponding with one really adsorbed by the adsorbent, and showed good retention capability for Pd(II) even at the absorbed dose of 800 kGy. The chromatographic separation of metal ions was demonstrated with the adsorbent packed column, there is no influence of Re(VII) (instead of Tc) on the excellent separation behavior of Pd(II). (authors)

  16. Determination of polymer additives-antioxidants and ultraviolet (UV) absorbers by high-performance liquid chromatography coupled with UV photodiode array detection in food simulants.

    Science.gov (United States)

    Gao, Yali; Gu, Yanxiang; Wei, Yun

    2011-12-28

    An analytical method for the quantitative determination of migration levels of polymer additives such as antioxidants and UV absorbers in food packages by high-performance liquid chromatography coupled with UV-vis photodiode array detection has been developed. The pretreatment step involved solid-phase extraction with silica C18 cartridges. The analytical method showed good linearity, presenting regression coefficients (R(2)) ≥ 0.9990 for all compounds. This optimized method was also validated with respect to precision, reproducibility, stability, and accuracy. The limits of detection and quantification were between 0.09 and 1.72 μg mL(-1) and between 0.20 and 5.64 μg mL(-1) for 12 analytes, respectively. Recoveries were in the range of 67.48 and 108.55%, with relative standard deviations between 2.76 and 9.81%. Migration levels of antioxidants and UV absorbers were determined. Butylated hydroxyanisole, 2,6-di-tert-butyl-4-methylphenol (BHT), 2,4-di-tert-butylphenol, Cyanox 2246, Irganox 1035, Tinuvin 326, Tinuvin 328, Irganox 1010, and Irganox 1330 were detected; BHT and Cyanox 2246 were at higher levels than the specific migration levels in some food simulants.

  17. Simultaneous flame ionization and absorbance detection of volatile and nonvolatile compounds by reversed-phase liquid chromatography with a water mobile phase.

    Science.gov (United States)

    Bruckner, C A; Ecker, S T; Synovec, R E

    1997-09-01

    A flame ionization detector (FID) is used to detect volatile organic compounds that have been separated by water-only reversed-phase liquid chromatography (WRP-LC). The mobile phase is 100% water at room temperature, without use of organic solvent modifiers. An interface between the LC and detector is presented, whereby a helium stream samples the vapor of volatile components from individual drops of the LC eluent, and the vapor-enriched gas stream is sent to the FID. The design of the drop headspace cell is simple because the water-only nature of the LC separation obviates the need to do any organic solvent removal prior to gas phase detection. Despite the absence of organic modifier, hydrophobic compounds can be separated in a reasonable time due to the low phase volume ratio of the WRP-LC columns. The drop headspace interface easily handles LC flows of 1 mL/min, and, in fact, compound detection limits are improved at faster liquid flow rates. The transfer efficiency of the headspace interface was estimated at 10% for toluene in water at 1 mL/min but varies depending on the volatility of each analyte. The detection system is linear over more than 5 orders of 1-butanol concentration in water and is able to detect sub-ppb amounts of o-xylene and other aromatic compounds in water. In order to analyze volatile and nonvolatile analytes simultaneously, the FID is coupled in series to a WRP-LC system with UV absorbance detection. WRP-LC improves UV absorbance detection limits because the absence of organic modifier allows the detector to be operated in the short-wavelength UV region, where analytes generally have significantly larger molar absorptivities. The selectivity the headspace interface provides for flame ionization detection of volatiles is demonstrated with a separation of 1-butanol, 1,1,2-trichloroethane (TCE), and chlorobenzene in a mixture of benzoic acid in water. Despite coelution of butanol and TCE with the benzoate anion, the nonvolatile benzoate anion

  18. Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235nm.

    Science.gov (United States)

    da Silveira Petruci, João Flavio; Liebetanz, Michael G; Cardoso, Arnaldo Alves; Hauser, Peter C

    2017-08-25

    In this communication, we describe a flow-through optical absorption detector for HPLC using for the first time a deep-UV light-emitting diode with an emission band at 235nm as light source. The detector is also comprised of a UV-sensitive photodiode positioned to enable measurement of radiation through a flow-through cuvette with round aperture of 1mm diameter and optical path length of 10mm, and a second one positioned as reference photodiode; a beam splitter and a power supply. The absorbance was measured and related to the analyte concentration by emulating the Lambert-Beer law with a log-ratio amplifier circuitry. This detector showed noise levels of 0.30mAU, which is comparable with our previous LED-based detectors employing LEDs at 280 and 255nm. The detector was coupled to a HPLC system and successfully evaluated for the determination of the anti-diabetic drugs pioglitazone and glimepiride in an isocratic separation and the benzodiazepines flurazepam, oxazepam and clobazam in a gradient elution. Good linearities (r>0.99), a precision better than 0.85% and limits of detection at sub-ppm levels were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Analysis of electrophoretic soil humic acids fractions by reversed-phase high performance liquid chromatography with on-line absorbance and fluorescence detection.

    Science.gov (United States)

    Trubetskoj, Oleg A; Richard, Claire; Guyot, Ghislain; Voyard, Guillaume; Trubetskaya, Olga E

    2012-06-22

    A combination of reversed-phase high performance liquid chromatography (RP HPLC) with on-line absorbance and fluorescence detection was used for analysis of chernozem soil humic acids (HAs) and their fractions A, B and C+D with different electrophoretic mobility (EM) and molecular size (MS). Samples were injected onto the column at the identical volume and absorbance. All chromatograms exhibit the resolution of seven peaks. The estimation of relative recovery of HAs and fractions from the reverse-phase column has been done. High MS fraction A, which possesses the low EM, is essentially more hydrophobic (73% of the fraction amount remained adsorbed on the column) and aliphatic than medium MS and EM fraction B (33% of the fraction amount remained adsorbed on the column). The most hydrophilic and aromatic properties belong to low MS fraction C+D, which possess the highest EM and practically was not adsorbed on the column. The hydrophobicity of the bulk HAs lies within the range of fractions hydrophobicity. The absorption spectra of bulk HAs, electrophoretic fractions A, B, C+D and corresponding RP HPLC peaks were featureless but had differences in the values of absorbance ratio at 300 and 400 nm (A3/A4). For fractions A and B this ratio gradually decreased from peak 1 to 7 (from 3.05 to 2.80 and 3.00 to 2.40, respectively). This trend was less pronounced in HAs and practically absent in fraction C+D, where ratio A3/A4 varied within a small range. The strong relationship between fluorescence properties, EM, MS, polarity and aliphaticity/aromaticity of HAs fractions was found. Humic and protein-like fluorescence had different polarity nature. The protein-like fluorescence is located in humic material which irreversibly adsorbed on the reverse-phase column and not subjected to RP HPLC characterization. The humic-like fluorescence at Ex/Em 270/450 nm is mostly located in the hydrophilic peak of low MS fraction C+D. Taking into account that high MS fraction A consisted

  20. Study on the Dissolution of Absorbent Cotton in Ionic Liquid%脱脂棉在离子液体中的溶解性能研究

    Institute of Scientific and Technical Information of China (English)

    吴良煜; 朱虎; 李友明; 万小芳; 刘晓雯

    2012-01-01

    有效地合成了离子液体1-烯丙基-3-甲基咪唑氯代盐([Amim]Cl),并探讨了脱脂棉纤维素在该离子液体中的溶解性能。测定了原、再生纤维素的聚合度,结果表明溶解前后纤维素的聚合度发生了很大变化,随着溶解温度的提高、时间的延长,再生纤维素聚合度降低;采用红外光谱、x-射线衍射及热重分析等手段对脱脂棉纤维素在离子液体[Amim]Cl中溶解和再生前后的结构变化进行了分析。结果表明,脱脂棉纤维素可直接溶解于离子液体[Amim]Cl而不发生其它衍生化反应。再生纤维素较原纤维素结晶状态由纤维素Ⅰ转变为纤维素Ⅱ,再生后纤维素热分解温度降低,热稳定性略有下降。%Ionic liquid, 1-allyl-3-methylimidazolium ([ Amim] Cl), has been successfully synthesized, and then applied as solvent for absorbent cotton cellulose with high degree of polymerization(DP). The DP of both original and regenerated cellulose have been measured, and the results show a big change between them. As the dissolving temperature rises and dissolving time extends, the DP of cellulose drops in a certain degree. The physicchemical properties of the regenerated cellulose films have been characterized by X-ray diffractometer (XRD) , infrared spectrometric analyzer (FTIR), thermogravimetric analysis (TGA) and differential scanning calorimeter (DSC). The results show that 1-ally-3-methylimidazolium chloride is a good non-derivatizing solvent to absorbent cotton. The crystalline form of absorbent cotton transforms completely from cellulose Ⅰ to cellulose Ⅱ after regeneration from [ Amim] Cl solution and the regenerated cellulose exhibits a lower temperature of thermal decomposition and slightly decreased thermal stability.

  1. Estimate of the Impact of Absorbing Aerosol Over Cloud on the MODIS Retrievals of Cloud Optical Thickness and Effective Radius Using Two Independent Retrievals of Liquid Water Path

    Science.gov (United States)

    Wilcox, Eric M.; Harshvardhan; Platnick, Steven

    2009-01-01

    Two independent satellite retrievals of cloud liquid water path (LWP) from the NASA Aqua satellite are used to diagnose the impact of absorbing biomass burning aerosol overlaying boundary-layer marine water clouds on the Moderate Resolution Imaging Spectrometer (MODIS) retrievals of cloud optical thickness (tau) and cloud droplet effective radius (r(sub e)). In the MODIS retrieval over oceans, cloud reflectance in the 0.86-micrometer and 2.13-micrometer bands is used to simultaneously retrieve tau and r(sub e). A low bias in the MODIS tau retrieval may result from reductions in the 0.86-micrometer reflectance, which is only very weakly absorbed by clouds, owing to absorption by aerosols in cases where biomass burning aerosols occur above water clouds. MODIS LWP, derived from the product of the retrieved tau and r(sub e), is compared with LWP ocean retrievals from the Advanced Microwave Scanning Radiometer-EOS (AMSR-E), determined from cloud microwave emission that is transparent to aerosols. For the coastal Atlantic southern African region investigated in this study, a systematic difference between AMSR-E and MODIS LWP retrievals is found for stratocumulus clouds over three biomass burning months in 2005 and 2006 that is consistent with above-cloud absorbing aerosols. Biomass burning aerosol is detected using the ultraviolet aerosol index from the Ozone Monitoring Instrument (OMI) on the Aura satellite. The LWP difference (AMSR-E minus MODIS) increases both with increasing tau and increasing OMI aerosol index. During the biomass burning season the mean LWP difference is 14 g per square meters, which is within the 15-20 g per square meter range of estimated uncertainties in instantaneous LWP retrievals. For samples with only low amounts of overlaying smoke (OMI AI less than or equal to 1) the difference is 9.4, suggesting that the impact of smoke aerosols on the mean MODIS LWP is 5.6 g per square meter. Only for scenes with OMI aerosol index greater than 2 does the

  2. Parallel microscope-based fluorescence, absorbance and time-of-flight mass spectrometry detection for high performance liquid chromatography and determination of glucosamine in urine.

    Science.gov (United States)

    Xiong, Bo; Wang, Ling-Ling; Li, Qiong; Nie, Yu-Ting; Cheng, Shuang-Shuang; Zhang, Hui; Sun, Ren-Qiang; Wang, Yu-Jiao; Zhou, Hong-Bin

    2015-11-01

    A parallel microscope-based laser-induced fluorescence (LIF), ultraviolet-visible absorbance (UV) and time-of-flight mass spectrometry (TOF-MS) detection for high performance liquid chromatography (HPLC) was achieved and used to determine glucosamine in urines. First, a reliable and convenient LIF detection was developed based on an inverted microscope and corresponding modulations. Parallel HPLC-LIF/UV/TOF-MS detection was developed by the combination of preceding Microscope-based LIF detection and HPLC coupled with UV and TOF-MS. The proposed setup, due to its parallel scheme, was free of the influence from photo bleaching in LIF detection. Rhodamine B, glutamic acid and glucosamine have been determined to evaluate its performance. Moreover, the proposed strategy was used to determine the glucosamine in urines, and subsequent results suggested that glucosamine, which was widely used in the prevention of the bone arthritis, was metabolized to urines within 4h. Furthermore, its concentration in urines decreased to 5.4mM at 12h. Efficient glucosamine detection was achieved based on a sensitive quantification (LIF), a universal detection (UV) and structural characterizations (TOF-MS). This application indicated that the proposed strategy was sensitive, universal and versatile, and it was capable of improved analysis, especially for analytes with low concentrations in complex samples, compared with conventional HPLC-UV/TOF-MS.

  3. Sound Absorbers

    Science.gov (United States)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  4. Absorbent product to absorb fluids. [for collection of human wastes

    Science.gov (United States)

    Dawn, F. S.; Correale, J. V. (Inventor)

    1982-01-01

    A multi-layer absorbent product for use in contact with the skin to absorb fluids is discussed. The product utilizes a water pervious facing layer for contacting the skin, overlayed by a first fibrous wicking layer, the wicking layer preferably being of the one-way variety in which fluid or liquid is moved away from the facing layer. The product further includes a first container section defined by inner and outer layer of a water pervious wicking material between which is disposed a first absorbent mass. A second container section defined by inner and outer layers between which is disposed a second absorbent mass and a liquid impermeable/gas permeable layer. Spacesuit applications are discussed.

  5. Carbon Monoxide (CO) Poisoning Prevention

    Science.gov (United States)

    ... Recommend on Facebook Tweet Share Compartir When power outages occur after severe weather (such as winter storms, hurricanes or tornadoes), using alternative sources of power can cause carbon monoxide (CO) to build up in a ...

  6. Carbon Monoxide Mixing Ratio System

    Data.gov (United States)

    Oak Ridge National Laboratory — The Southern Great Plains (SGP) Carbon Monoxide (CO) system provides high-precision atmospheric concentration measurements of CO mixing ratio (ppbv dry air) every 10...

  7. Electro-removal of H-3 and C-14 contained in scintillation liquid absorbed in soils type Phaeozem; Electrorremocion de H-3 y C-14 contenidos en liquido de centelleo absorbidos en suelos tipo Phaeozem

    Energy Technology Data Exchange (ETDEWEB)

    Valdovinos, V.; Bustos, E. [Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, Parque Tecnologico Queretaro s/n, San Fandila, 76703 Pedro Escobedo, Queretaro (Mexico); Monroy G, F., E-mail: vvaldovinos@cideteq.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    This paper presents the results of electro-removal, an electrochemical treatment in soils contaminated with H-3 and C-14 contained in scintillation liquids absorbed in soils. For this purpose the best electrochemical conditions were used, which are: scintillation liquid Ultima Gold Xr, water (1:1) and 1 m A in the passage of current. The media were characterized before and after of applying the different potentials by various analytical techniques, such as: liquids by gas chromatography with a flame ionization detector, solids and liquids by Fourier transform infrared spectroscopy (Ftir) and electrodes by scanning electron microscopy with elemental analysis by energy-dispersive X-ray spectroscopy. Later standard samples with H-3 and C-14 were prepared and the electrochemical treatment was applied to previously established conditions. After electrochemical treatment the scintillation liquid characterization was performed by gas chromatography and a scintillation counter to see the disintegrations per minute. According to results of Ftir, soils show no deterioration and in the liquid phase the amount of water increases as the applied potential, due to oxidation-reduction reactions where happen modification or mineralization of organic molecules (H{sub 2}O and CO{sub 2} formation). In 4 h of treatment, removal percentages in the liquid phase, were: 53.6% of H-3 and 11.6% of C-14. (Author)

  8. Combination of multivariate curve resolution and multivariate classification techniques for comprehensive high-performance liquid chromatography-diode array absorbance detection fingerprints analysis of Salvia reuterana extracts.

    Science.gov (United States)

    Hakimzadeh, Neda; Parastar, Hadi; Fattahi, Mohammad

    2014-01-24

    In this study, multivariate curve resolution (MCR) and multivariate classification methods are proposed to develop a new chemometric strategy for comprehensive analysis of high-performance liquid chromatography-diode array absorbance detection (HPLC-DAD) fingerprints of sixty Salvia reuterana samples from five different geographical regions. Different chromatographic problems occurred during HPLC-DAD analysis of S. reuterana samples, such as baseline/background contribution and noise, low signal-to-noise ratio (S/N), asymmetric peaks, elution time shifts, and peak overlap are handled using the proposed strategy. In this way, chromatographic fingerprints of sixty samples are properly segmented to ten common chromatographic regions using local rank analysis and then, the corresponding segments are column-wise augmented for subsequent MCR analysis. Extended multivariate curve resolution-alternating least squares (MCR-ALS) is used to obtain pure component profiles in each segment. In general, thirty-one chemical components were resolved using MCR-ALS in sixty S. reuterana samples and the lack of fit (LOF) values of MCR-ALS models were below 10.0% in all cases. Pure spectral profiles are considered for identification of chemical components by comparing their resolved spectra with the standard ones and twenty-four components out of thirty-one components were identified. Additionally, pure elution profiles are used to obtain relative concentrations of chemical components in different samples for multivariate classification analysis by principal component analysis (PCA) and k-nearest neighbors (kNN). Inspection of the PCA score plot (explaining 76.1% of variance accounted for three PCs) showed that S. reuterana samples belong to four clusters. The degree of class separation (DCS) which quantifies the distance separating clusters in relation to the scatter within each cluster is calculated for four clusters and it was in the range of 1.6-5.8. These results are then

  9. Enantiomeric analysis of beta-pinene and limonene by direct coupling of reversed phase liquid chromatography and gas chromatography using absorbents as packing materials.

    Science.gov (United States)

    Flores, Gema; Ruiz del Castillo, Maria Luisa; Herraiz, Marta

    2007-11-01

    A method based on the use of absorbents as packing materials inside the interface of the online coupling between RPLC and GC is proposed for the enantiomeric analysis of beta-pinene and limonene in essential oils. For that purpose, a comparison of the RSD, detection limit and recovery provided by two absorbents and one adsorbent is included in this study. The results found in this work proved the validity of absorbents as packing materials in online RPLC-GC to determine minor compounds in complex matrices. In particular, PDMS seemed to be specially useful to analyse nonpolar compounds, such as beta-pinene and limonene, since it provided higher sensitivity for this kind of compounds. The developed method was applied to the evaluation of the natural and non-natural character of commercial essential oils by means of the determination of the enantiomeric composition of beta-pinene and limonene.

  10. (Carbon monoxide metabolism by photosynthetic bacteria)

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    Research continued on the metabolism of carbon monoxide by Rhodospirillum rubrum. This report discusses progress on the activity, induction, inhibition, and spectroscopic analysis of the enzyme Carbon Monoxide Dehydrogenase. (CBS)

  11. Carbon Monoxide Silicate Reduction System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Carbon Monoxide Silicate Reduction System (COSRS) is an innovative method that for the first time uses the strong reductant carbon monoxide to both reduce iron...

  12. Carbon monoxide formation in tomatoes

    Energy Technology Data Exchange (ETDEWEB)

    Gladon, R.J.; Staby, G.L.

    1979-01-01

    Carbon monoxide (CO) is not emanated to any large extent from tomato fruits (Lycopersicon esculentum, Mill. cvs. Rutgers and Ohio MR-13), but is retained within the internal atmosphere. CO is found during all stages of fruit development, but no set pattern of CO concentration is evident.

  13. MOPITT Carbon Monoxide Over India

    Science.gov (United States)

    2002-01-01

    MOPITT observed high levels of carbon monoxide (red and yellow pixels) over the Indian sub-continent during March. These values are associated with industrial activity in the region just south of the Himalayan Mountains. Notice that to the north, the Himalayas are characterized by low values (blue pixels).

  14. On the relations between viable bacteria counts and absorbency of fermented liquid of lactobacillus%乳酸菌培养液中活菌数与吸光度的关系研究

    Institute of Scientific and Technical Information of China (English)

    严佩峰; 张孔海; 李建芳

    2012-01-01

    This test studied on relations between viable bacteria counts and corresponding absorbency of fermented liquid using skim milk as culture medium.The result showed that the relation between viable bacteria counts and its absorbency is linear correlation while taking skim milk as culture medium in the fermented course.So we can infer viable bacteria counts in the fermented dairy products through determining its absorbency in the fermented course.%通过平板计数法测定脱脂乳为培养基的发酵液中乳酸菌的活菌数,并测其对应的吸光度,研究两者之间的相关关系。结果表明:在发酵过程中以脱脂乳为培养基的发酵液中乳酸菌的活菌数与吸光度之间呈线性相关关系。因此,通过测定发酵液的吸光度可以评定发酵乳制品中乳酸菌的活菌数。

  15. Improved determination of urinary cortisol and cortisone, or corticosterone and 11-dehydrocorticosterone by high-performance liquid chromatography with ultraviolet absorbance detection.

    Science.gov (United States)

    Hay, M; Mormède, P

    1997-11-21

    A sensitive assay was developed for the determination of low levels of free (unconjugated) glucocorticoids in human, swine (cortisol and cortisone) and rat urine (corticosterone and 11-dehydrocorticosterone), using solid-phase extraction and HPLC with UV absorbance detection (254 nm). Precise quantitation is allowed by the use of internal standards (dexamethasone for swine urine and Reichstein's substance S for rat urine). This simple method allows the use of small urine samples (less than 2 ml), and is suitable for a wide range of applications in human and animal clinical and physiological studies.

  16. Absorbent product and articles made therefrom

    Science.gov (United States)

    Dawn, F. S.; Correale, J. V. (Inventor)

    1982-01-01

    A multilayer absorbent product for use in contact with the skin to absorb fluids is described. The product has a water pervious facing layer for contacting the skin, and a first fibrous wicking layer overlaying the water pervious layer. A first container section is defined by inner and outer layers of a water pervious wicking material in between a first absorbent mass and a second container section defined by inner and outer layers of a water pervious wicking material between what is disposed a second absorbent mass, and a liquid impermeable/gas permeable layer overlaying the second fibrous wicking layer.

  17. Carbon monoxide kinetics following simulated cigarette smoking

    Energy Technology Data Exchange (ETDEWEB)

    Karnik, A.S. (Wayne State Univ., Detroit, MI); Coin, E.J.

    1980-05-01

    Carbon monoxide kinetics were measured in the blood (% carboxyhemoglobin) and alveolar phase (ppM carbon monoxide) after simulated cigarette smoking. Cigarette smoking was siumlated using the same amount of carbon monoxide that 2R1F cigarettes manufactured by the Tobacco Research Institute would contain. Ten boluses of air containing carbon monoxide equivalent to smoking one cigarette were inhaled by six healthy nonsmoker volunteers. Carbon monoxide in the air phase was measured by an Ecolyzer and carboxyhemoglobin was measured by a CO-Oximeter. The mean rise in alveolar carbon monoxide immediately and 20 min after inhaling the last bolus was 3.3 and 3.1 ppM, respectively (p<.005). The mean rise in carboxyhemoglobin immediately and 20 min after inhalation of the last bolus was 0.8 and 0.5% respectively (P<.005). The changes in carboxyhemoglobin were found to be similar to changes that occur when one cigarette is actually smoked.

  18. Performance of a new carbon dioxide absorbent, Yabashi lime® as compared to conventional carbon dioxide absorbent during sevoflurane anesthesia in dogs

    OpenAIRE

    KONDOH, Kei; ATIBA, Ayman; NAGASE, Kiyoshi; Ogawa, Shizuko; Miwa, Takashi; KATSUMATA, Teruya; Ueno, Hiroshi; UZUKA, Yuji

    2015-01-01

    In the present study, we compare a new carbon dioxide (CO2) absorbent, Yabashi lime® with a conventional CO2 absorbent, Sodasorb® as a control CO2 absorbent for Compound A (CA) and Carbon monoxide (CO) productions. Four dogs were anesthetized with sevoflurane. Each dog was anesthetized with four preparations, Yabashi lime® with high or low-flow rate of oxygen and control CO2 absorbent with high or low-flow rate. CA and CO concentrations in the anesthetic circuit, canister temperature and carb...

  19. Toward absolute chemical composition distribution measurement of polyolefins by high-temperature liquid chromatography hyphenated with infrared absorbance and light scattering detectors.

    Science.gov (United States)

    Lee, Dean; Shan, Colin Li Pi; Meunier, David M; Lyons, John W; Cong, Rongjuan; deGroot, A Willem

    2014-09-02

    Chemical composition distribution (CCD) is a fundamental metric for representing molecular structures of copolymers in addition to molecular weight distribution (MWD). Solvent gradient interaction chromatography (SGIC) is commonly used to separate copolymers by chemical composition in order to obtain CCD. The separation of polymer in SGIC is, however, not only affected by chemical composition but also by molecular weight and architecture. The ability to measure composition and MW simultaneously after separation would be beneficial for understanding the impact of different factors and deriving true CCD. In this study, comprehensive two-dimensional chromatography (2D) was coupled with infrared absorbance (IR5) and light scattering (LS) detectors for characterization of ethylene-propylene copolymers. Polymers were first separated by SGIC as the first dimension chromatography (D1). The separated fractions were then characterized by the second dimension (D2) size exclusion chromatography (SEC) with IR5 and LS detectors. The concentrations and compositions of the separated fractions were measured online using the IR5 detector. The MWs of the fractions were measured by the ratio of LS to IR5 signals. A metric was derived from online concentration and composition data to represent CCD breadth. The metric was shown to be independent of separation gradients for an "absolute" measurement of CCD breadth. By combining online composition and MW data, the relationship of MW as a function of chemical composition was obtained. This relationship was qualitatively consistent with the results by SEC coupled to IR5, which measures chemical composition as a function of logMW. The simultaneous measurements of composition and MW give the opportunity to study the SGIC separation mechanism and derive chain architectural characteristics of polymer chains.

  20. Carbon monoxide conversion by anaerobic bioreactor sludges

    NARCIS (Netherlands)

    Sipma, J.; Stams, A.J.M.; Lens, P.N.L.; Lettinga, G.

    2003-01-01

    Seven different anaerobic sludges from wastewater treatment reactors were screened for their ability to convert carbon monoxide (CO) at 30 and 55degreesC
    Seven different anaerobic sludges from wastewater treatment reactors were screened for their ability to convert carbon monoxide (CO) at 30 and

  1. Development of a rapid method based on solid-phase extraction and liquid chromatography with ultraviolet absorbance detection for the determination of polyphenols in alcohol-free beers.

    Science.gov (United States)

    García, A Alonso; Grande, B Cancho; Gándara, J Simal

    2004-10-29

    An analytical method based on solid-phase extraction (SPE) and followed by liquid chromatographic separation and ultraviolet detection (HPLC-UV) is proposed for the determination of 10 phenolic compounds which participate on beer stability and sensory properties in alcohol-free beers. Acetonitrile was found to be the most appropriate solvent for the elution of polyphenolic compounds adsorbed on C18 cartridges. The performance of the method was assessed by the evaluation of parameters such as absolute recovery (generally higher than 60%), repeatability (lower than 10%), linearity (r2 higher than 0.993) and limits of quantitation (ranging from 1 to 37 microg/L); no matrix effects were observed. The polyphenol content of different Spanish alcohol-free beers is presented. Five phenolic compounds such as protocatechuic, p-coumaric, ferulic, caffeic acids, and (+)-catechin were identified at levels lower than 10 mg/L.

  2. Characterization of therapeutic antibodies and related products by two-dimensional liquid chromatography coupled with UV absorbance and mass spectrometric detection.

    Science.gov (United States)

    Stoll, Dwight; Danforth, John; Zhang, Kelly; Beck, Alain

    2016-10-01

    The development of analytical tools for the characterization of large biomolecules is an emerging and rapidly evolving area. This development activity is motivated largely by the current trend involving the increase in development and use of large biomolecules for therapeutic uses. Given the inherent complexity of these biomolecules, which arises from their sheer size and possibilities for chemical modification as well as changes over time (e.g., through modification in solution, aggregation), two-dimensional liquid chromatography (2D-LC) has attracted considerable interest as an analytical tool to address the challenges faced in characterizing these materials. The immediate potential benefits of 2D-LC over conventional one-dimensional liquid chromatography in this context include: (1) higher overall resolving power; (2) complementary information gained from two dimensions of separation in a single analysis; and (3) enabling indirect coupling of separation modes that are inherently incompatible with mass spectrometric (MS) detection (e.g., ion-exchange, because of high-salt eluents) to MS through a more compatible second dimension separation such as reversed-phase LC. In this review we summarize the work in this area, most of which has occurred in the past five years. Although the future is bright for further development in this area, some challenges have already been addressed through new 2D-LC methods. These include: (1) deep characterization of monoclonal antibodies to understand charge heterogeneity, glycosylation patterns, and other modifications; (2) characterization of antibody-drug conjugates to understand the extent and localization of small molecule conjugation; (3) detailed study of excipients in protein drug formulations; and (4) detection of host-cell proteins on biotherapeutic molecule preparations. We fully expect that in the near future we will see this list expanded, and that continued development will lead to methods with further improved

  3. Composite absorbing potentials

    CERN Document Server

    Palao, J P; Sala, P R

    1998-01-01

    The multiple scattering interferences due to the addition of several contiguous potential units are used to construct composite absorbing potentials that absorb at an arbitrary set of incident momenta or for a broad momentum interval.

  4. The ALICE absorbers

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Weighing more than 400 tonnes, the ALICE absorbers and the surrounding support structures have been installed and aligned with a precision of 1-2 mm, hardly an easy task but a very important one. The ALICE absorbers are made of three parts: the front absorber, a 35-tonne cone-shaped structure, and two small-angle absorbers, long straight cylinder sections weighing 18 and 40 tonnes. The three pieces lined up have a total length of about 17 m.

  5. Profiling and identification of the absorbed constituents and metabolites of schisandra lignans by ultra-performance liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Sun, Hui; Wu, Fangfang; Zhang, Aihua; Wei, Wenfeng; Han, Ying; Wang, Xijun

    2013-11-01

    Schisandra chinensis Baill grows wild in Russia, China, Korea and Japan, and its fruit has been found to be effective in amnesia and insomnia. It is enriched in schisandra lignans (SL) that are major components responsible for therapeutic action. However, there are no reports on the biotransformation analysis of SL. An ultra-performance liquid chromatography/electrospray-ionization high-definition mass spectrometry (UPLC-Q-TOF-HDMS) method was developed to investigate the metabolism of SL in vivo. MS was performed on a Waters Micromass high-definition system with an electrospray ionization source in positive ion mode and automated MetaboLynx software analysis with excellent MS accuracy and enhanced MS data acquisition. An improved mass defect filter (MDF) method employing both drug and core structure filter templates was applied to the processing of UPLC-Q-TOF-HDMS data for the detection and structural characterization of metabolites. In this study, 30 metabolites were detected and identified in vivo, and demethylation and hydroxylation were confirmed as the primacy metabolic pathway for SL in rat plasma. In conclusion, the presently developed methodology was suitable for biotransformation research of SL and will find wide use in metabolic studies for other herbal medicines.

  6. The Carbon Monoxide Tape Recorder

    Science.gov (United States)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  7. Engineering evidence for carbon monoxide toxicity cases.

    Science.gov (United States)

    Galatsis, Kosmas

    2016-07-01

    Unintentional carbon monoxide poisonings and fatalities lead to many toxicity cases. Given the unusual physical properties of carbon monoxide-in that the gas is odorless and invisible-unorganized and erroneous methods in obtaining engineering evidence as required during the discovery process often occurs. Such evidence gathering spans domains that include building construction, appliance installation, industrial hygiene, mechanical engineering, combustion and physics. In this paper, we attempt to place a systematic framework that is relevant to key aspects in engineering evidence gathering for unintentional carbon monoxide poisoning cases. Such a framework aims to increase awareness of this process and relevant issues to help guide legal counsel and expert witnesses.

  8. Delayed encephalopathy after acute carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Mehmet İbrahim Turan

    2014-03-01

    Full Text Available Carbon monoxide poisoning is a major cause of death following attempted suicide and accidental exposures. Although clinical presentation depends on the duration and the intensity of exposure, the assessment of the severity of intoxication is difficult. A small percentage of patients who show complete initial recovery may develop delayed neurological deficits. Delayed encephalopathy after acute carbon monoxide poisoning is a rare and poor prognosis neurologic disorders and there is no specific treatment. We present a case with early onset of delayed encephalopathy after acute carbon monoxide poisoning with typical cranial imaging findings in a child with atypical history and clinical presentation.

  9. Material processing with hydrogen and carbon monoxide on Mars

    Science.gov (United States)

    Hepp, Aloysius F.; Landis, Geoffrey A.; Linne, Diane L.

    1991-01-01

    Several novel proposals are examined for propellant production from carbon dioxide and monoxide and hydrogen. Potential uses were also examined of CO as a fuel or as a reducing agent in metal oxide processing as obtained or further reduced to carbon. Hydrogen can be reacted with CO to produce a wide variety of hydrocarbons, alcohols, and other organic compounds. Methanol, produced by Fischer-Tropsch chemistry may be useful as a fuel; it is easy to store and handle because it is a liquid at Mars temperatures. The reduction of CO2 to hydrocarbons such as methane or acetylene can be accomplished with hydrogen. Carbon monoxide and hydrogen require cryogenic temperatures for storage as liquids. Noncryogenic storage of hydrogen may be accomplished using hydrocarbons, inorganic hydrides, or metal hydrides. Noncryogenic storage of CO may be accomplished in the form of iron carbonyl (FE(CO)5) or other metal carbonyls. Low hydrogen content fuels such as acetylene (C2H2) may be effective propellants with low requirements for earth derived resources. The impact on manned Mars missions of alternative propellant production and utilization is discussed.

  10. Scientific Opinion on the safety evaluation of the active substances citric acid (E330 and sodium hydrogen carbonate (E500ii, used as carbon dioxide generators, together with liquid absorbers cellulose and polyacrylic acid sodium salt crosslinked, in active food contact materials

    Directory of Open Access Journals (Sweden)

    EFSA Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids (CEF

    2013-04-01

    Full Text Available This scientific opinion of EFSA Panel on food contact materials, enzymes, flavourings and processing aids deals with the safety evaluation of the mixture of the active substances citric acid (E330, CAS No 77-92-9, FCM Substance No 139 and sodium hydrogen carbonate (E500ii, CAS No 144-55-8, FCM Substance No 21, which is intended to be used as a carbon dioxide generator in liquid absorbent pads in the packaging of fresh or frozen meat, poultry, fish, fruits and vegetables. Depending on absorption capacity needed, pure cellulose or a mixture of cellulose and polyacrylic acid sodium salt crosslinked may be used as absorber. The Panel noted that if the active substances are used not in direct contact with food, but are placed in a pad under conditions where its absorption capacity is not exceeded, then no migration is to be expected and therefore no exposure from the consumption of the packed food is expected. Therefore the CEF Panel concluded that the use of the mixture of the active substances citric acid (E330 and sodium hydrogen carbonate (E500ii, as carbon dioxide generator in liquid absorbent pads in the packaging of food such as fresh or frozen meat, poultry, fish, fruits and vegetables, does not raise a safety concern. The absorbent pads should be used only under conditions in which the liquid absorption capacity is not exceeded and direct contact between the substance and the food is excluded.

  11. Carbon Monoxide Silicate Reduction System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Carbon Monoxide Silicate Reduction System (COSRS) is a novel technology for producing large quantities of oxygen on the Moon. Oxygen yields of 15 kilograms per...

  12. Protect Yourself from Carbon Monoxide Poisoning

    Centers for Disease Control (CDC) Podcasts

    2007-11-20

    Learn about carbon monoxide - a colorless, odorless gas - and how to protect yourself and your family.  Created: 11/20/2007 by CDC National Center for Environmental Health.   Date Released: 12/4/2007.

  13. Assessment of exposure to carbon monoxide group of firefighters from fire fighting and rescue units

    Directory of Open Access Journals (Sweden)

    Jadwiga Lembas-Bogaczyk

    2011-03-01

    Full Text Available Firemen threat during fire burning of chemical substances indicated presence of carbon monoxide (CO in all cases. Carbon monoxide causes death of fire. Inhaled through respiratory system, links with hemoglobin, thus blocking transport and distribution of oxygen in the body. This leads to tissue anoxia, which is a direct threat to firefighters’ life. The purpose of this study was to assess the exposure to carbon monoxide of participating firefighters extinguishing fire. Estimation of carbon monoxide quantity absorbed by firefighters was isolated in a group of 40 firefighters from Fire Extinguishing and Rescue Unit of State Fire in Nysa. The study was conducted by measuring carbon monoxide in exhaled air. For measurement of carbon monoxide concentration in exhaled air Micro CO meter was used. Results were demonstrated separately for nonsmokers (n425 and smokers (n415. Mean COHb[%] levels in nonsmokers, measured prior the rescue action was 0,3950,3% and increased statistically significant after the action to 0,6150,34%, while in the group smokers, this level was 2,1750,64% before the action and increased insignificantly after the action to 2,3350,63%. The average COHb level in the same groups before and after exercise, was respectively: for nonsmokers prior to exercise was 0,4850,28% and after exercise decreased statistically significant to 0,3050,27%. In the group of smokers before exercise was 2,2350,61% and decreased statistically significant up to 1,5450,71%. It was no difference between the group of age and time of employment.

  14. Integrated electricity and carbon monoxide production

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, J.

    1994-03-23

    In a process for the production of carbon monoxide and electric power in an IGCC with the removal of sulphur compounds, between the outlet of quenched gas from a partial oxidation unit and a fuel inlet to a combined cycle gas turbine there is a permeable membrane unit to separate a non-permeable stream, which is utilised as a source of carbon monoxide, and a permeate stream, which is used as fuel for the gas turbine of the combined cycle unit. (author)

  15. Hearing Loss due to Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mehrparvar

    2013-01-01

    Full Text Available Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker after an acute exposure to carbon monoxide. This complication was diagnosed by pure-tone audiometry and confirmed by transient evoked otoacoustic emissions. Hearing loss has not improved after 3 months of followup.

  16. Advanced neutron absorber materials

    Science.gov (United States)

    Branagan, Daniel J.; Smolik, Galen R.

    2000-01-01

    A neutron absorbing material and method utilizing rare earth elements such as gadolinium, europium and samarium to form metallic glasses and/or noble base nano/microcrystalline materials, the neutron absorbing material having a combination of superior neutron capture cross sections coupled with enhanced resistance to corrosion, oxidation and leaching.

  17. Absorbing Outflows in AGN

    Science.gov (United States)

    Mathur, Smita

    2002-01-01

    The goal of this program was a comprehensive multiwavelength study of absorption phenomena in active galactic nuclei (AGN). These include a variety of associated absorption systems: X-ray warm absorbers, X-ray cold absorbers. UV absorbers with high ionization lines, MgII absorbers, red quasars and BALQSOs. The aim is to determine the physical conditions in the absorbing outflows, study their inter-relations and their role in AGN. We designed several observing programs to achieve this goal: X-ray spectroscopy, UV spectroscopy, FLAY spectroscopy and X-ray imaging. We were very successful towards achieving the goal over the five year period as shown through following observing programs and papers. Copies of a few papers are attached with this report.

  18. The Dry-filling System for the Shock Absorber of Car Engine

    Directory of Open Access Journals (Sweden)

    Du Rong

    2016-01-01

    Full Text Available The shock absorber is considered as an important component of the suspension system. In its production process, the liquid filling for the shock absorber is a very important part. This paper introduced one kind of shock absorber stem–filling system, which achieved liquid dry-filling in the shock absorber for the car engine. The results showed that this system is stable and reliable.

  19. Multiband terahertz metamaterial absorber

    Institute of Scientific and Technical Information of China (English)

    Gu Chao; Qu Shao-Bo; Pei Zhi-Bin; Xu Zhuo; Liu Jia; Gu Wei

    2011-01-01

    This paper reports the design of a multiband metamaterial (MM) absorber in the terahertz region. Theoretical and simulated results show that the absorber has four distinct and strong absorption points at 1.69, 2.76, 3.41 and that the impedance of MM could be tuned to match approximately the impedance of the free space to minimise the reflectance at absorption frequencies and large power loss exists at absorption frequencies. The distribution of the power loss indicates that the absorber is an excellent electromagnetic wave collector: the wave is first trapped and reinforced in certain specific locations and then consumed. This multiband absorber has applications in the detection of explosives and materials characterisation.

  20. TOMS Absorbing Aerosol Index

    Data.gov (United States)

    Washington University St Louis — TOMS_AI_G is an aerosol related dataset derived from the Total Ozone Monitoring Satellite (TOMS) Sensor. The TOMS aerosol index arises from absorbing aerosols such...

  1. Electrodynamic absorber theory

    OpenAIRE

    Deckert, Dirk-André

    2010-01-01

    This work deals with questions that arise in classical and quantum electrodynamics when describing the phenomena of radiation reaction and pair creation. The two guiding ideas are the absorber idea of Wheeler and Feynman (i.e. all emitted radiation will be again be absorbed by matter) and the electron sea idea of Dirac. In the first part classical dynamics are studied which allow for a description of radiation reaction without the need of renormalization. The starting point are the couple...

  2. Pulmonary edema in acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis.

  3. 40 CFR 60.103 - Standard for carbon monoxide.

    Science.gov (United States)

    2010-07-01

    ... Refineries § 60.103 Standard for carbon monoxide. Each owner or operator of any fluid catalytic cracking unit... regenerator any gases that contain carbon monoxide (CO) in excess of 500 ppm by volume (dry basis)....

  4. [Carbon monoxide metabolism by photosynthetic bacteria]. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    1989-12-31

    Research continued on the metabolism of carbon monoxide by Rhodospirillum rubrum. This report discusses progress on the activity, induction, inhibition, and spectroscopic analysis of the enzyme Carbon Monoxide Dehydrogenase. (CBS)

  5. Carbon Monoxide Hazards from Small Gasoline Powered Engines

    Science.gov (United States)

    ... Topics Publications and Products Programs Contact NIOSH NIOSH CARBON MONOXIDE Recommend on Facebook Tweet Share Compartir On this Page Recommendations NIOSH Publications Worker Notification Program Carbon Monoxide Hazards from Small Gasoline Powered Engines Many ...

  6. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb...

  7. Hearing Loss due to Carbon Monoxide Poisoning

    DEFF Research Database (Denmark)

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker...

  8. Unidirectional perfect absorber

    Science.gov (United States)

    Jin, L.; Wang, P.; Song, Z.

    2016-09-01

    This study proposes a unidirectional perfect absorber (UPA), which we realized with a two-arm Aharonov-Bohm interferometer, that consists of a dissipative resonator side-coupled to a uniform resonator array. The UPA has reflection-less full absorption on one direction, and reflectionless full transmission on the other, with an appropriate magnetic flux and coupling, detuning, and loss of the side-coupled resonator. The magnetic flux controls the transmission, the left transmission is larger for magnetic flux less than one-half flux quantum; and the right transmission is larger for magnetic flux between one-half and one flux quantum. Besides, a perfect absorber (PA) can be realized based on the UPA, in which light waves from both sides, with arbitrary superposition of the ampli- tude and phase, are perfectly absorbed. The UPA is expected to be useful in the design of novel optical devices.

  9. Neutron absorbing alloy

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Masayuki

    1998-12-04

    The neutron absorbing alloy of the present invention comprises Ti or an alloy thereof as a mother material, to which from 2 to 40% by weight of Hf and Gd within a range of from 4 to 50% by weight in total are added respectively. Ti is excellent in specific strength, corrosion resistance and workability, and produces no noxious intermetallic compound with Hf and Gd. In addition, since the alloy can incorporate a great quantity of Hf and Gd, a neutron absorbing material having excellent neutron absorbing performance than usual and excellent in specific strength, corrosion resistance and workability can be manufactured conveniently and economically not by a special manufacturing method. (T.M.)

  10. Metasurface Broadband Solar Absorber

    CERN Document Server

    Azad, A K; Sykora, M; Weisse-Bernstein, N R; Luk, T S; Taylor, A J; Dalvit, D A R; Chen, H -T

    2015-01-01

    We demonstrate a broadband, polarization independent, omnidirectional absorber based on a metallic metasurface architecture, which accomplishes greater than 90% absorptance in the visible and near-infrared range of the solar spectrum, and exhibits low emissivity at mid- and far-infrared wavelengths. The complex unit cell of the metasurface solar absorber consists of eight pairs of gold nano-resonators that are separated from a gold ground plane by a thin silicon dioxide spacer. Our experimental measurements reveal high-performance absorption over a wide range of incidence angles for both s- and p-polarizations. We also investigate numerically the frequency-dependent field and current distributions to elucidate how the absorption occurs within the metasurface structure. Furthermore, we discuss the potential use of our metasurface absorber design in solar thermophotovoltaics by exploiting refractory plasmonic materials.

  11. Black Liquid Solar Collector Demonstrator.

    Science.gov (United States)

    Weichman, F. L.; Austen, D. J.

    1979-01-01

    Describes the details of constructing, and use of, a solar collector. Uses a black liquid to absorb the energy, the thermosyphon effect to drive the liquid through the collector, and a floodlamp as a surrogate sun. (GA)

  12. Solar concentrator/absorber

    Science.gov (United States)

    Von Tiesenhausen, G. F.

    1976-01-01

    Collector/energy converter, consisting of dual-slope optical concentrator and counterflow thermal energy absorber, is attached to multiaxis support structure. Efficient over wide range of illumination levels, device may be used to generate high temperature steam, serve as solar powered dryer, or power absorption cycle cooler.

  13. Modeling and analysis of a circular PZT energy-generator used in hydraulic liquid absorber%液压流体吸振器用圆形压电发电装置的建模与性能分析

    Institute of Scientific and Technical Information of China (English)

    王淑云; 阚君武; 王鸿云; 李征; 赵子超; 万杰; 曹迪

    2012-01-01

    A piezoelectric energy harvester used in hydraulic liquid absorber was presented. To enhance the energy-generating capability and obtain the optimal structural/material parameters, the analysis model of clamped PZT disk generator under concentrated force was established utilizing the theory of plates and shells. The influences of radius ratio (λ) , thickness ratio (β) as well as material Young's modulus ratio ( ζ) of the PZT disk on energy generation were investigated. The results show that there is an optimal pair of X and β for a PZT disk generator with given ζ to obtain maximal electrical energy. Similarly, in the case of given X and β, there is an optimal ζ, which decreases with the decrease of β and is not influenced by the change of X under given β. At the same time, reducing ζ is helpful for the generator to generate more electrical energy. When aluminum or beryllium bronze plates are used as substrates, the optimal radius ratio and thickness ratio are (0.45, 0.45) or (0.585, 0.6), respectively. The maximal electric energy generated are 1.14643 x 10 -4J and 1.01893 x 10-4J, respectively.%提出一种用于液压流体吸振器的压电发电装置.为提高所用圆形压电振子的发电能力,获得最优的结构及材料性能参数,利用板壳理论建立了固支边界条件下的位移曲线及发电量的理论分析模型,研究了半径比(陶瓷/基板)、厚度比(陶瓷/总厚度)及弹性模量比(基板/陶瓷)等对其发电能力的影响规律.研究表明,在压电振子材料确定时,存在最佳的半径比和厚度比使其发电能力最大;在压电振子结构尺寸确定时,存在最佳的弹性模量比使发电量最大,且厚度比确定时的最佳弹性模量比与半径比无关、半径比确定时的最佳弹性模量比随厚度比的减小而降低;减小弹性模量比有助于提高压电振子的发电能力.铝基板及铍青铜基板压电振子的最佳半径比/厚度比分别为0.45/0.45和0

  14. Photosynthetic carbon monoxide metabolism by sugarcane leaves

    Energy Technology Data Exchange (ETDEWEB)

    Kortschak, H.P.; Nickell, L.G.

    1973-01-01

    The photosynthetic carbon monoxide metabolism by sugarcane was studied to determine whether substantial quantities of CO are removed from the air by fields in Hawaii. Leaves metabolized low CO concentrations photosynthetically, with sucrose as an end product. Rates of uptake were of the order of 10/sup -4/ power mg/d sq m/hr. This was to low to be significant in removing CO from the atmosphere.

  15. Sensorineural Hearing Loss following Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Joseph P. Pillion

    2012-01-01

    Full Text Available A case study is presented of a 17-year-old male who sustained an anoxic brain injury and sensorineural hearing loss secondary to carbon monoxide poisoning. Audiological data is presented showing a slightly asymmetrical hearing loss of sensorineural origin and mild-to-severe degree for both ears. Word recognition performance was fair to poor bilaterally for speech presented at normal conversational levels in quiet. Management considerations of the hearing loss are discussed.

  16. Optimal Sound Absorbing Structures

    CERN Document Server

    Yang, Min; Fu, Caixing; Sheng, Ping

    2016-01-01

    Causal nature of the acoustic response, for any materials or structures, dictates an inequality that relates the absorption spectrum of the sample to its thickness. We present a general recipe for constructing sound-absorbing structures that can attain near-equality for the causal relation with very high absorption performance; such structures are denoted optimal. Our strategy involves using carefully designed acoustic metamaterials as backing to a thin layer of conventional sound absorbing material, e.g., acoustic sponge. By using this design approach, we have realized a 12 cm-thick structure that exhibits broadband, near-perfect flat absorption spectrum starting at around 400 Hz. From the causal relation, the calculated minimum sample thickness is 11.5 cm for the observed absorption spectrum. We present the theory that underlies such absorption performance, involving the evanescent waves and their interaction with a dissipative medium, and show the excellent agreement with the experiment.

  17. Universal metamaterial absorbe

    CERN Document Server

    Smaali, Rafik; Moreau, Antoine; Taliercio, Thierry; Centeno, Emmanuel

    2016-01-01

    We propose a design for an universal absorber, characterized by a resonance frequency that can be tuned from visible to microwave frequencies independently of the choice of the metal and the dielectrics involved. An almost resonant perfect absorption up to 99.8 % is demonstrated at resonance for all polarization states of light and for a very wide angular aperture. These properties originate from a magnetic Fabry-Perot mode that is confined in a dielectric spacer of $\\lambda/100$ thickness by a metamaterial layer and a mirror. An extraordinary large funneling through nano-slits explains how light can be trapped in the structure. Simple scaling laws can be used as a recipe to design ultra-thin perfect absorbers whatever the materials and the desired resonance wavelength, making our design truly universal.

  18. Absorbable and biodegradable polymers

    CERN Document Server

    Shalaby, Shalaby W

    2003-01-01

    INTRODUCTION NOTES: Absorbable/Biodegradable Polymers: Technology Evolution. DEVELOPMENT AND APPLICATIONOF NEW SYSTEMS: Segmented Copolyesters with Prolonged Strength Retention Profiles. Polyaxial Crystalline Fiber-Forming Copolyester. Polyethylene Glycol-Based Copolyesters. Cyanoacrylate-Based Systems as Tissue Adhesives. Chitosan-Based Systems. Hyaluronic Acid-Based Systems. DEVELOPMENTS IN PREPARATIVE, PROCESSING, AND EVALUATION METHODS: New Approaches to the Synthesis of Crystalline. Fiber-Forming Aliphatic Copolyesters. Advances in Morphological Development to Tailor the Performance of Me

  19. Ionized Absorbers in AGN

    Science.gov (United States)

    Mathur, S.

    1999-01-01

    As a part of this program, we observed three AGN:PKS2251 + 113, PG0043 = 039 and PLH909. Two objects show signatures of absorbtion in their UV spectra. Based on our earlier modeling of X-ray warm absorbents, we expected to observe X-ray observation in these objects. The third, PLH909, is known to have soft excess in EINSTEIN data. Attachment: "Exploratory ASCA observation of broad absorption line quasi-stellar objects".

  20. Clustering of Absorbers

    CERN Document Server

    Cristiani, S; D'Odorico, V; Fontana, A; Giallongo, E; Moscardini, L; Savaglio, S

    1997-01-01

    The observed clustering of Lyman-$\\alpha$ lines is reviewed and compared with the clustering of CIV systems. We argue that a continuity of properties exists between Lyman-$\\alpha$ and metal systems and show that the small-scale clustering of the absorbers is consistent with a scenario of gravitationally induced correlations. At large scales statistically significant over and under-densities (including voids) are found on scales of tens of Mpc.

  1. Metamaterial Absorbers in Terahertz Band

    Institute of Scientific and Technical Information of China (English)

    Qi-Ye Wen; Huai-Wu Zhang; Qing-Hui Yang; Man-Man Mo

    2013-01-01

    In recent years, a great deal of effort has been made to a create terahertz (THz) wave absorber based on metamaterials (MM). Metamaterials absorbers have a variety of potential applications including thermal emitters, detector, stealth technology, phase imaging, etc. In this paper, we firstly introduce the basic structure and work principle of the THz MM absorbers, and a transmission line model is developed for devices analysis. To expand the application of THz absorbers, dual-band and broadband THz MM absorbers are designed, fabricated, and measured. At the end of this article, the future development trends of MM absorbers are discussed.

  2. Theory of microslit absorbers

    Institute of Scientific and Technical Information of China (English)

    MAA Dah-You

    2001-01-01

    It is well known that narrow slit may be used as acoustical element. The exact formulae of the acoustical impedance of a narrow slit and its low-frequency approximation are available. The theory of slit is extended and a simple and practical formula is derived for the single slit. It is found that the resistance-to-reactance ratio of the slit increases to larger than one when the slit width is decreased to submillimeter range, and a panel with extremely narrow slits plus a back cavity will make an absorber with good absorption in a wide frequency range,without any porous or fibrous material. A complete theory of the microslit absorber (MSA) is, thus, presented and its absorption characteristics discussed. It is found that the MSA has essentially the same formulae as the microperforate absorber (MPA), except that the numerical coefficient of the resistance is smaller and the end correction for the mass reactance is larger for the MSA, resulting a performance inferior to that of MPA, ordinarily. Measures are proposed to compensate for these.

  3. Absorber for terahertz radiation management

    Science.gov (United States)

    Biallas, George Herman; Apeldoorn, Cornelis; Williams, Gwyn P.; Benson, Stephen V.; Shinn, Michelle D.; Heckman, John D.

    2015-12-08

    A method and apparatus for minimizing the degradation of power in a free electron laser (FEL) generating terahertz (THz) radiation. The method includes inserting an absorber ring in the FEL beam path for absorbing any irregular THz radiation and thus minimizes the degradation of downstream optics and the resulting degradation of the FEL output power. The absorber ring includes an upstream side, a downstream side, and a plurality of wedges spaced radially around the absorber ring. The wedges form a scallop-like feature on the innermost edges of the absorber ring that acts as an apodizer, stopping diffractive focusing of the THz radiation that is not intercepted by the absorber. Spacing between the scallop-like features and the shape of the features approximates the Bartlett apodization function. The absorber ring provides a smooth intensity distribution, rather than one that is peaked on-center, thereby eliminating minor distortion downstream of the absorber.

  4. Corrosion resistant neutron absorbing coatings

    Science.gov (United States)

    Choi, Jor-Shan [El Cerrito, CA; Farmer, Joseph C [Tracy, CA; Lee, Chuck K [Hayward, CA; Walker, Jeffrey [Gaithersburg, MD; Russell, Paige [Las Vegas, NV; Kirkwood, Jon [Saint Leonard, MD; Yang, Nancy [Lafayette, CA; Champagne, Victor [Oxford, PA

    2012-05-29

    A method of forming a corrosion resistant neutron absorbing coating comprising the steps of spray or deposition or sputtering or welding processing to form a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material. Also a corrosion resistant neutron absorbing coating comprising a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material.

  5. A Perfect Terahertz Metamaterial Absorber

    CERN Document Server

    Bagheri, Alireza

    2015-01-01

    In this paper the design for an absorbing metamaterial with near unity absorbance in terahertz region is presented. The absorber's unit cell structure consists of two metamaterial resonators that couple to electric and magnetic fields separately. The structure allows us to maximize absorption by varying dielectric material and thickness and, hence the effective electrical permittivity and magnetic permeability.

  6. Absorber-evaporator unit for an absorption-refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Hallatt, R.J.; Rorschach, R.L.

    1965-01-26

    This low temperature absorption-refrigeration system uses an absorber-evaporator. A conduit is connected between the upper portion of the absorber and the lower portion of the evaporator to conduct inert gas from the absorber to the evaporator. A second conduit connects the upper portion of the evaporator to the lower portion of the absorber and a blower in this conduit circulates the inert gas through the closed system. By placing the blower between the evaporator ad the absorber, the pressure in the evaporator is maintained at a minimum so that the working temperature is as low as possible. The medium to be cooled by the refrigerant is circulated through a heat exchanger located within the evaporator, whereby the latent heat of vaporization of the liquid refrigerant is employed to cool the outside medium. (2 claims)

  7. New Technology in Hydrogen Absorbers for Muon Cooling Channels

    CERN Document Server

    Cummings, M A C

    2005-01-01

    Ionization cooling is the only technique fast enough to cool and focus muons for neutrino factories and muon colliders, and hydrogen is the optimal material for maximum cooling and minimal multiple scattering. Liquid hydrogen absorber R&D for the Muon Collaboration has proceeded on parallel and complementary fronts. The continuing LH2 absorber engineering and technical developments by the MuCool group conducted by ICAR* institutions (NIU, IIT and UIUC), the University of Mississippi and Oxford University, in cooperation with Fermilab, will be summarized, including results from the first hydrogen absorber tests at the newly constructed FNAL Mucool Test Area (MTA). The program includes designs for the high-powered test of an absorber prototype (external heat exchange) at the MTA which are nearing completion to be installed by summer 2005, an alternative absorber design (internal heat exchange) being finalized for the approved cooling experiment (MICE) at Rutherford-Appleton Laboratory, and a novel idea for ...

  8. Compact Instrument for Measurement of Atmospheric Carbon Monoxide Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Southwest Sciences proposed the development of a rugged, compact, and automated instrument for the high sensitivity measurement of tropospheric carbon monoxide...

  9. High-performance liquid chromatography - Ultraviolet method for the determination of total specific migration of nine ultraviolet absorbers in food simulants based on 1,1,3,3-Tetramethylguanidine and organic phase anion exchange solid phase extraction to remove glyceride.

    Science.gov (United States)

    Wang, Jianling; Xiao, Xiaofeng; Chen, Tong; Liu, Tingfei; Tao, Huaming; He, Jun

    2016-06-17

    The glyceride in oil food simulant usually causes serious interferences to target analytes and leads to failure of the normal function of the RP-HPLC column. In this work, a convenient HPLC-UV method for the determination of the total specific migration of nine ultraviolet (UV) absorbers in food simulants was developed based on 1,1,3,3-tetramethylguanidine (TMG) and organic phase anion exchange (OPAE) SPE to efficiently remove glyceride in olive oil simulant. In contrast to the normal ion exchange carried out in an aqueous solution or aqueous phase environment, the OPAE SPE was performed in the organic phase environments, and the time-consuming and challenging extraction of the nine UV absorbers from vegetable oil with aqueous solution could be readily omitted. The method was proved to have good linearity (r≥0.99992), precision (intra-day RSD≤3.3%), and accuracy(91.0%≤recoveries≤107%); furthermore, the lower limit of quantifications (0.05-0.2mg/kg) in five types of food simulants(10% ethanol, 3% acetic acid, 20% ethanol, 50% ethanol and olive oil) was observed. The method was found to be well suited for quantitative determination of the total specific migration of the nine UV absorbers both in aqueous and vegetable oil simulant according to Commission Regulation (EU) No. 10/2011. Migration levels of the nine UV absorbers were determined in 31 plastic samples, and UV-24, UV-531, HHBP and UV-326 were frequently detected, especially in olive oil simulant for UV-326 in PE samples. In addition, the OPAE SPE procedure was also been applied to efficiently enrich or purify seven antioxidants in olive oil simulant. Results indicate that this procedure will have more extensive applications in the enriching or purification of the extremely weak acidic compounds with phenol hydroxyl group that are relatively stable in TMG n-hexane solution and that can be barely extracted from vegetable oil.

  10. Sensing with THz metamaterial absorbers

    CERN Document Server

    Cong, Longqing

    2014-01-01

    Metamaterial perfect absorbers from microwaves to optical part of the electromagnetic spectrum has been intensely studied for its ability to absorb electromagnetic radiation. Perfect absorption of light by metamaterials have opened up new opportunities for application oriented functionalities such as efficient sensors and emitters. We present an absorber based sensing scheme at the terahertz frequencies and discuss optimized designs to achieve high frequency and amplitude sensitivities. The major advantage of a perfect metamaterial absorber as a sensor is the sensitive shift in the absorber resonance frequency along with the sharp change in the amplitude of the resonance due to strong interaction of the analyte with the electric and the magnetic fields at resonant perfect absorption frequency. We compare the sensing performance of the perfect metamaterial absorber with its complementary structural design and planar metasurface with identical structure. The best FoM values obtained for the absorber sensor here...

  11. Analysis of Carbon Monoxide in Blood

    Science.gov (United States)

    Huddle, Benjamin P.; Stephens, Joseph C.

    2003-04-01

    Forensic tests used to perform the qualitative and quantitative analyses of carbon monoxide in blood are described. The qualitative test uses the diffusion of CO, which is released from blood by reaction with H2SO4, into a PdCl2 solution in a Conway cell and the resultant formation of a palladium mirror. The quantitative analysis is based on the absorption of visible light by carboxyhemoglobin at 541 nm and reduced hemoglobin at 555 nm. Both procedures are suitable for undergraduate chemistry experiments.

  12. Photophoretic trampoline - Interaction of single airborne absorbing droplets with light

    CERN Document Server

    Esseling, Michael; Alpmann, Christina; Denz, Cornelia

    2012-01-01

    We present the light-induced manipulation of absorbing liquid droplets in air. Ink droplets from a printer cartridge are used to demonstrate that absorbing liquids - just like their solid counterparts - can interact with regions of high light intensity due to the photophoretic force. It is shown that droplets follow a quasi-ballistic trajectory after bouncing off a high intensity light sheet. We estimate the intensities necessary for this rebound of airborne droplets and change the droplet trajectories through a variation of the manipulating light field.

  13. Ferroelectrics based absorbing layers

    Science.gov (United States)

    Hao, Jianping; Sadaune, Véronique; Burgnies, Ludovic; Lippens, Didier

    2014-07-01

    We show that ferroelectrics-based periodic structure made of BaSrTiO3 (BST) cubes, arrayed onto a metal plate with a thin dielectric spacer film exhibit a dramatic enhancement of absorbance with value close to unity. The enhancement is found around the Mie magnetic resonance of the Ferroelectrics cubes with the backside metal layer stopping any transmitted waves. It also involves quasi-perfect impedance matching resulting in reflection suppression via simultaneous magnetic and electrical activities. In addition, it was shown numerically the existence of a periodicity optimum, which is explained from surface waves analysis along with trade-off between the resonance damping and the intrinsic loss of ferroelectrics cubes. An experimental verification in a hollow waveguide configuration with a good comparison with full-wave numerical modelling is at last reported by measuring the scattering parameters of single and dual BST cubes schemes pointing out coupling effects for densely packed structures.

  14. The Flexible Bass Absorber

    DEFF Research Database (Denmark)

    Adelman-Larsen, Niels Werner; Thompson, Eric Robert; Gade, Anders Christian

    2007-01-01

    Multi-purpose concert halls face a dilemma. They host different performance types that require significantly different acoustic conditions in order to provide the best sound quality to both the performers, sound engineers and the audience. Pop and rock music often contain high levels of bass soun...... has been developed. Measurements were made on a variable and mobile low-frequency absorber. The paper presents the results of prototype sound absorption measurements as well as elements of the design.......Multi-purpose concert halls face a dilemma. They host different performance types that require significantly different acoustic conditions in order to provide the best sound quality to both the performers, sound engineers and the audience. Pop and rock music often contain high levels of bass sound...

  15. The Flexible Bass Absorber

    DEFF Research Database (Denmark)

    Adelman-Larsen, Niels Werner; Thompson, Eric Robert; Gade, Anders Christian

    2007-01-01

    Multi-purpose concert halls face a dilemma. They host different performance types that require significantly different acoustic conditions in order to provide the best sound quality to both the performers, sound engineers and the audience. Pop and rock music often contains high levels of bass sou...... has been developed. Measurements were made on a variable and mobile low-frequency absorber. The paper presents the results of prototype sound absorption measurements as well as elements of the design.......Multi-purpose concert halls face a dilemma. They host different performance types that require significantly different acoustic conditions in order to provide the best sound quality to both the performers, sound engineers and the audience. Pop and rock music often contains high levels of bass sound...

  16. [Carbon monoxide poisoning by a heating system].

    Science.gov (United States)

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  17. Observations of iodine monoxide columns from satellite

    Directory of Open Access Journals (Sweden)

    A. Schönhardt

    2008-02-01

    Full Text Available Iodine species in the troposphere are linked to ozone depletion and new particle formation. In this study, a full year of iodine monoxide (IO columns retrieved from measurements of the SCIAMACHY satellite instrument is presented, coupled with a discussion of their uncertainties and the detection limits. The largest amounts of IO are found near springtime in the Antarctic. A seasonal variation of iodine monoxide in Antarctica is revealed with high values in springtime, slightly less IO in the summer period and again larger amounts in autumn. In winter, no elevated IO levels are found in the areas accessible to satellite measurements. This seasonal cycle is in good agreement with recent ground-based measurements in Antarctica. In the Arctic region, no elevated IO levels were found in the period analysed. This implies that different conditions with respect to iodine release exist in the two Polar Regions. To investigate possible release mechanisms, comparisons of IO columns with those of tropospheric BrO, and ice coverage are described and discussed. Some parallels and interesting differences between IO and BrO temporal and spatial distributions are identified. Overall, the large spatial coverage of satellite retrieved IO data and the availability of a long-term dataset provide new insight about the abundances and distributions of iodine compounds in the troposphere.

  18. Nitric oxide and carbon monoxide diffusing capacity of the lung

    NARCIS (Netherlands)

    Lee, I. van der

    2006-01-01

    The single breath diffusion capacity of the lung for carbon monoxide (DLCO) is measure for gas uptake by the lung, and consists of a membrane and a vascular component. Nitric oxide (NO) binds 400 times faster to hemoglobin than carbon monoxide, thus the uptake of NO by the blood is very large.

  19. Nitric oxide and carbon monoxide diffusing capacity of the lung

    NARCIS (Netherlands)

    Lee, I. van der

    2006-01-01

    The single breath diffusion capacity of the lung for carbon monoxide (DLCO) is measure for gas uptake by the lung, and consists of a membrane and a vascular component. Nitric oxide (NO) binds 400 times faster to hemoglobin than carbon monoxide, thus the uptake of NO by the blood is very large. There

  20. Fatal carbon monoxide intoxication after acetylene gas welding of pipes.

    Science.gov (United States)

    Antonsson, Ann-Beth; Christensson, Bengt; Berge, Johan; Sjögren, Bengt

    2013-06-01

    Acetylene gas welding of district heating pipes can result in exposure to high concentrations of carbon monoxide. A fatal case due to intoxication is described. Measurements of carbon monoxide revealed high levels when gas welding a pipe with closed ends. This fatality and these measurements highlight a new hazard, which must be promptly prevented.

  1. Real World of Industrial Chemistry: Organic Chemicals from Carbon Monoxide.

    Science.gov (United States)

    Kolb, Kenneth E.; Kolb, Doris

    1983-01-01

    Carbon Monoxide obtained from coal may serve as the source for a wide variety of organic compounds. Several of these compounds are discussed, including phosgene, benzaldehyde, methanol, formic acid and its derivatives, oxo aldehydes, acrylic acids, and others. Commercial reactions of carbon monoxide are highlighted in a table. (JN)

  2. Catalytic removal of carbon monoxide over carbon supported palladium catalyst

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Avanish Kumar [Defence Research and Development Establishment, Jhansi Road, Gwalior-474002 (MP) (India); Saxena, Amit [Centre for Fire Explosive and Environmental Safety, Timarpur, Delhi-110054 (India); Shah, Dilip; Mahato, T.H. [Defence Research and Development Establishment, Jhansi Road, Gwalior-474002 (MP) (India); Singh, Beer, E-mail: beerbs5@rediffmail.com [Defence Research and Development Establishment, Jhansi Road, Gwalior-474002 (MP) (India); Shrivastava, A.R.; Gutch, P.K. [Defence Research and Development Establishment, Jhansi Road, Gwalior-474002 (MP) (India); Shinde, C.P. [School of Studies in Chemistry, Jiwaji University, Gwalior-474002 (MP) (India)

    2012-11-30

    Highlights: Black-Right-Pointing-Pointer Carbon supported palladium (Pd/C) catalyst was prepared. Black-Right-Pointing-Pointer Catalytic removal of CO over Pd/C catalyst was studied under dynamic conditions. Black-Right-Pointing-Pointer Effects of Pd %, CO conc., humidity, GHSV and reaction environment were studied. - Abstract: Carbon supported palladium (Pd/C) catalyst was prepared by impregnation of palladium chloride using incipient wetness technique, which was followed by liquid phase reduction with formaldehyde. Thereafter, Pd/C catalyst was characterized using X-ray diffractometery, scanning electron microscopy, atomic absorption spectroscopy, thermo gravimetry, differential scanning calorimetry and surface characterization techniques. Catalytic removal of carbon monoxide (CO) over Pd/C catalyst was studied under dynamic conditions. Pd/C catalyst was found to be continuously converting CO to CO{sub 2} through the catalyzed reaction, i.e., CO + 1/2O{sub 2} {yields} CO{sub 2}. Pd/C catalyst provided excellent protection against CO. Effects of palladium wt%, CO concentration, humidity, space velocity and reaction environment were also studied on the breakthrough behavior of CO.

  3. The Hydration Structure of Carbon Monoxide by Ab Initio Methods

    CERN Document Server

    Awoonor-Williams, Ernest

    2016-01-01

    The solvation of carbon monoxide (CO) in liquid water is important for understanding its toxicological effects and biochemical roles. In this paper, we use ab initio molecular dynamics (AIMD) and CCSD(T)-F12 calculations to assess the accuracy of the Straub and Karplus molecular mechanical (MM) model for CO(aq). The CCSD(T)-F12 CO--H2O potential energy surfaces show that the most stable structure corresponds to water donating a hydrogen bond to the C center. The MM-calculated surface it incorrectly predicts that the O atom is a stronger hydrogen bond acceptor than the C atom. The AIMD simulations indicate that CO is solvated like a hydrophobic solute, with very limited hydrogen bonding with water. The MM model tends to overestimate the degree of hydrogen bonding and overestimates the atomic radius of the C atom. The calculated Gibbs energy of hydration is in good agreement with experiment (9.3 kJ/mol calc. vs 10.7 kJ/mol exptl.). The calculated diffusivity of CO(aq) in TIP3P-model water was 5.19 x 10-5 cm2/s ...

  4. Absorbency of Superabsorbent Polymers in Cementitious Environments

    DEFF Research Database (Denmark)

    Esteves, Luis Pedro; Jensen, Ole Mejlhede

    2012-01-01

    Optimal use of superabsorbent polymers (SAP) in cement-based materials relies on knowledge on how SAP absorbency is influenced by different physical and chemical parameters. These parameters include salt concentration in the pore fluid, temperature of the system and SAP particle size. The present...... composition of the exposure liquid is investigated with atomic absorption spectroscopy. The paper provides the reader with knowledge about the absorption capacity of SAP in a cementitious environment, and how the absorption process may influence the cement pore fluid....

  5. The rat bowel of β-asaron absorbs the research

    Institute of Scientific and Technical Information of China (English)

    QI Yue; JIA Dong; YOU Xian-min; ZOU Gui-xin; JIANG Hong

    2008-01-01

    Objective Study the β-asaron under the condition that the bowel each segment of rat and be worth in the diffent medicine density and pH of the absorption dynamics characteristic, as to it's the rat absorbs the part in the body and it absorbs the mechanism to carry on the study, for the further design β-asaron settle release the product to provide the living creature medicine learn the basis. Methods Apply the rat to the body to infuse to flow the bowel absorption experiment investigation and absorption dynamics characteristic;adopt the HPLC method measurement β-asaron is in rat body the bowel absorbs the medicine density within the reflux liquid. Results It absorb the quantity and β-asaron of the medicine in the reflux liquid, the density of β-asaron becomes the direct proption, the absorption speed constant of the medicine is basic and constant within the scope of the 19 μg·mL-1- 57 μg·mL-1; In the pH is 5.6; 6.9; 8.0 three kinds of dissimilarities lie the absorption velocity constant of the quality and absorb the of percentage and also did not show the difference of salience;β-asaron is in the small intestines the lower part absorb better, absorbthe velocity to press to return to bowel, ileum, jejunum, duodenum, colon to descend one by one in order, absorb the velocity constant one by one in order is 0.402, 0.396, 0.385, 0.325 h-1. Conclusions β-asaron absorbs to present a class absorption dynamics characteristic in the bowel way, absorbing the mechanism as passive absorption; in order to return to ileum and jejunums, main absorption part there is certain absorption in the colon, too.

  6. Search of medical literature for indoor carbon monoxide exposure

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  7. Ammonia-water absorption in vertical tubular absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, Jose; Sieres, Jaime; Rodriguez, Cristobal; Vazquez, Manuel [Area de Maquinas y Motores Termicos, Escuela Tecnica Superior de Ingenieros Industriales, Campus Lagoas-Marcosende, No 9, 36200 Vigo (Spain)

    2005-03-01

    This paper presents a detailed analysis of the heat and mass transfer processes during the absorption of ammonia into water in a co-current vertical tubular absorber. The absorber configuration is of the shell and tubes type. The absorption process progresses as the vapour and liquid contact inside the tubes. Water is used as the absorber cooling medium. A differential mathematical model has been developed on the basis of mass and energy balances and heat and mass transfer equations, in order to provide further understanding of the absorber behaviour. The model takes into account separately for the churn, slug and bubbly flow patterns experimentally forecasted in this type of absorption processes inside vertical tubes and considers the simultaneous heat and mass transfer processes in both liquid and vapour phases, as well as heat transfer to the cooling medium. The model equations have been solved using the finite-difference method. Results obtained for specific data are depicted to show local values of the most important variables all along the absorber length. Parametric analyses have been performed to show the influence of design parameters and operating conditions on the absorber performance. The effect of the heat and mass transfer coefficients has also been evaluated. (authors)

  8. Quantification of Mycosphaerella fijiensis in vitro growth by absorbance readings

    Directory of Open Access Journals (Sweden)

    Mileidy Cruz-Martín

    2013-10-01

    Full Text Available The slow growth of Mycosphaerella fijiensis Morelet in synthetic and semi-synthetic media as well as the characteristics of their colonies makes the use of traditional methods for evaluating the fungal growth are inadequate and impractical. Therefore, it requires a method to quantify growth in small volumes of substance and in short periods of time. The aim of this study was to quantify the M. fijiensis growth, through absorbance readings on the time, of mycelial suspensions obtained from cultures in liquid medium. Mycelial dry weight of the pathogen grown in liquid culture in flasks of 250 ml capacity and the absorbance in 96 well plates was compared. Similar procedure was used to evaluate the effect of bacterial culture filtrates with in vitro antifungal activity against M. fijiensis. A linear relationship between absorbance at 595 nm of fungal growth in liquid culture medium with respect to the dry mass was found. Absorbance readings using 96-well plates were possible to quantify the M. fijiensis mycelial suspensions growth in liquid culture. Also, there may be applied to assess the growth inhibition of the pathogen for bacterial culture filtrates with results at 48 h incubation. Key words: antifungal activity assay, biomass, DO595

  9. Absorbed Dose Distribution in a Pulse Radiolysis Optical Cell

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    When a liquid solution in an optical cell is irradiated by an intense pulsed electron beam, it may be important in the chemical analysis of the solution to know the distribution of energy deposited throughout the cell. For the present work, absorbed dose distributions were measured by thin...

  10. Reduction of carbon monoxide. Past research summary

    Energy Technology Data Exchange (ETDEWEB)

    Schrock, R.R.

    1981-10-01

    Research programs for the year on the preparation, characterization, and reactions of binuclear tantalum complexes are described. All evidence to date suggest the following of these dimeric molecules: (1) the dimer does not break into monomers under mild conditions; (2) intermolecular hydride exchange is not negligible, but it is slow; (3) intermolecular non-ionic halide exchange is fast; (4) the ends of the dimers can rotate partially with respect to one another. The binuclear tantalum hydride complexes were found to react with carbon monoxide to give a molecule which is the only example of reduction of CO by a transition metal hydride to give a complex containing a CHO ligand. Isonitrides also reacted in a similar manner with dimeric tantalum hydride. (ATT)

  11. Performance of a new carbon dioxide absorbent, Yabashi lime® as compared to conventional carbon dioxide absorbent during sevoflurane anesthesia in dogs.

    Science.gov (United States)

    Kondoh, Kei; Atiba, Ayman; Nagase, Kiyoshi; Ogawa, Shizuko; Miwa, Takashi; Katsumata, Teruya; Ueno, Hiroshi; Uzuka, Yuji

    2015-08-01

    In the present study, we compare a new carbon dioxide (CO2) absorbent, Yabashi lime(®) with a conventional CO2 absorbent, Sodasorb(®) as a control CO2 absorbent for Compound A (CA) and Carbon monoxide (CO) productions. Four dogs were anesthetized with sevoflurane. Each dog was anesthetized with four preparations, Yabashi lime(®) with high or low-flow rate of oxygen and control CO2 absorbent with high or low-flow rate. CA and CO concentrations in the anesthetic circuit, canister temperature and carbooxyhemoglobin (COHb) concentration in the blood were measured. Yabashi lime(®) did not produce CA. Control CO2 absorbent generated CA, and its concentration was significantly higher in low-flow rate than a high-flow rate. CO was generated only in low-flow rate groups, but there was no significance between Yabashi lime(®) groups and control CO2 absorbent groups. However, the CO concentration in the circuit could not be detected (≤5ppm), and no change was found in COHb level. Canister temperature was significantly higher in low-flow rate groups than high-flow rate groups. Furthermore, in low-flow rate groups, the lower layer of canister temperature in control CO2 absorbent group was significantly higher than Yabashi lime(®) group. CA and CO productions are thought to be related to the composition of CO2 absorbent, flow rate and canister temperature. Though CO concentration is equal, it might be safer to use Yabashi lime(®) with sevoflurane anesthesia in dogs than conventional CO2 absorbent at the point of CA production.

  12. Improvement Of The Helmholtz Absorber

    Science.gov (United States)

    Morrow, Duane L.

    1992-01-01

    Helmholtz-resonator system improved to enable it to absorb sound at more than one frequency without appreciable loss of effectiveness at primary frequency. Addition of annular cavities enables absorption of sound at harmonic frequencies in addition to primary frequency. Improved absorber designed for use on structures of high transmission loss. Applied to such machines as fixed-speed engines and fans.

  13. Absorbent pads for Containment, Neutralization, and Clean-Up of Environmental Spills Containing Chemically-Reactive Agents

    Science.gov (United States)

    Davis, Dennis D. (Inventor)

    1997-01-01

    A pad for cleaning up liquid spills is described which contains a porous surface covering, and an absorbent interior containing chemically reactive reagents for neutralizing noxious chemicals within the spilled liquid. The porous surface and the absorbent component would normally consist of chemically resistant materials allowing tentative spill to pass. The absorbent interior which contains the neutralizing reagents can but is not required to be chemically resilient and conducts the liquid chemical spill towards the absorbent interior containing the chemically reactive reagents where the dangerous and undesirable chemicals within the chemical spill are then neutralized as well as removed from the premises.

  14. Leaf absorbance and photosynthesis

    Science.gov (United States)

    Schurer, Kees

    1994-01-01

    The absorption spectrum of a leaf is often thought to contain some clues to the photosynthetic action spectrum of chlorophyll. Of course, absorption of photons is needed for photosynthesis, but the reverse, photosynthesis when there is absorption, is not necessarily true. As a check on the existence of absorption limits we measured spectra for a few different leaves. Two techniques for measuring absorption have been used, viz. the separate determination of the diffuse reflectance and the diffuse transmittance with the leaf at a port of an integrating sphere and the direct determination of the non-absorbed fraction with the leaf in the sphere. In a cross-check both methods yielded the same results for the absorption spectrum. The spectrum of a Fuchsia leaf, covering the short-wave region from 350 to 2500 nm, shows a high absorption in UV, blue and red, the well known dip in the green and a steep fall-off at 700 nm. Absorption drops to virtually zero in the near infrared, with subsequent absorptions, corresponding to the water absorption bands. In more detailed spectra, taken at 5 nm intervals with a 5 nm bandwidth, differences in chlorophyll content show in the different depths of the dip around 550 nm and in a small shift of the absorption edge at 700 nm. Spectra for Geranium (Pelargonium zonale) and Hibiscus (with a higher chlorophyll content) show that the upper limit for photosynthesis can not be much above 700 nm. No evidence, however, is to be seen of a lower limit for photosynthesis and, in fact, some experiments down to 300 nm still did not show a decrease of the absorption although it is well recognized that no photosynthesis results with 300 nm wavelengths.

  15. Visible light broadband perfect absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Jia, X. L.; Meng, Q. X.; Yuan, C. X.; Zhou, Z. X.; Wang, X. O., E-mail: wxo@hit.edu.cn [School of Science, Harbin Institute of Technology, Harbin 150001 (China)

    2016-03-15

    The visible light broadband perfect absorbers based on the silver (Ag) nano elliptical disks and holes array are studied using finite difference time domain simulations. The semiconducting indium silicon dioxide thin film is introduced as the space layer in this sandwiched structure. Utilizing the asymmetrical geometry of the structures, polarization sensitivity for transverse electric wave (TE)/transverse magnetic wave (TM) and left circular polarization wave (LCP)/right circular polarization wave (RCP) of the broadband absorption are gained. The absorbers with Ag nano disks and holes array show several peaks absorbance of 100% by numerical simulation. These simple and flexible perfect absorbers are particularly desirable for various potential applications including the solar energy absorber.

  16. Syncope Associated with Carbon Monoxide Poisoning due to Narghile Smoking

    Directory of Open Access Journals (Sweden)

    Seda Ozkan

    2013-01-01

    Full Text Available Narghile smoking is a traditional method of tobacco use, and it has been practiced extensively for 400 years. Traditionally, narghile smoking is a matter of culture mainly in Middle East, Asia, and Africa. In recent years, its use as a social activity has increased worldwide, especially among young people. Narghile smoking is an unusual cause of carbon monoxide poisoning. Narghile smoking, compared to cigarette smoking, can result in more smoke exposure and greater levels of carbon monoxide. We present an acute syncope case of a 19-year-old male patient who had carbon monoxide poisoning after narghile smoking.

  17. Nd:YGG crystal laser at 1110 nm: a potential source for detecting carbon monoxide poisoning.

    Science.gov (United States)

    Yu, Haohai; Wu, Kui; Zhang, Huaijin; Wang, Zhengping; Wang, Jiyang; Jiang, Minhua

    2011-04-01

    We demonstrated a laser-diode pumped Nd-doped yttrium gallium garnet crystal laser at 1110 nm for the first time to our knowledge. By suppressing the oscillation at about 1.06 μm, continuous-wave output power of 2.1 W at 1110 nm was achieved. With a Cr:YAG as the saturable absorber, the passive Q-switching performance at this wavelength was obtained. The shortest pulse width and largest pulse energy were 31.5 ns and 22.7 μJ, respectively. Laser radiation at this wavelength is an important source for detecting carbon monoxide poisoning by simple frequency doubling with a nonlinear crystal.

  18. Evidence for significant photochemical production of carbon monoxide by particles in coastal and oligotrophic marine waters

    Science.gov (United States)

    Xie, Huixiang; Zafiriou, Oliver C.

    2009-12-01

    Carbon monoxide (CO) photoproduction from particulate and chromophoric dissolved organic matter (CDOM) was determined in seawater from open-ocean and coastal areas. In confirmatory tests, poisoned or non-poisoned filtered and unfiltered blue-water samples, were exposed to sunlight. CO photoproduction was 21-42% higher in the unfiltered than in the filtered samples. In a more thorough study utilizing concentrated particles prepared by 0.2-μm cross-flow filtration, samples containing varying levels of particles were irradiated under simulated solar radiation. Their CO photoproduction rates increased linearly with particle concentration factor. Particulate CO production was 11-35% of CDOM-based CO production. On an absorbed-photons basis, the former was 30-108% more efficient than the latter. This study suggests that in both coastal and blue waters these new-found particulate photoprocesses are of similar biogeochemical importance to the well-known CDOM photoproduction term.

  19. Carbon monoxide production from degradation of desflurane, enflurane, isoflurane, halothane, and sevoflurane by soda lime and Baralyme.

    Science.gov (United States)

    Fang, Z X; Eger, E I; Laster, M J; Chortkoff, B S; Kandel, L; Ionescu, P

    1995-06-01

    Anecdotal reports suggest that soda lime and Baralyme brand absorbent can degrade inhaled anesthetics to carbon monoxide (CO). We examined the factors that govern CO production and found that these include: 1) The anesthetic used: for a given minimum alveolar anesthetic concentration (MAC)-multiple, the magnitude of CO production (greatest to least) is desflurane > or = enflurane > isoflurane > halothane = sevoflurane. 2) The absorbent dryness: completely dry soda lime produces much more CO than absorbent with just 1.4% water content, and soda lime containing 4.8% or more water (standard soda lime contains 15% water) generates no CO. In contrast, both completely dry Baralyme and Baralyme with 1.6% water produce high concentrations of CO, and Baralyme containing 4.7% water produces concentrations equaling those produced by soda lime containing 1.4% water. Baralyme containing 9.7% or more water and standard Baralyme (13% water) do not generate CO.3) The type of absorbent: at a given water content, Baralyme produces more CO than does soda lime. 4) The temperature: an increased temperature increases CO production. 5) The anesthetic concentration: more CO is produced from higher anesthetic concentrations. These results suggest that CO generation can be avoided for all anesthetics by using soda lime with 4.8% (or more) water or Baralyme with 9.7% (or more) water, and by using inflow rates of less than 2-3 L/min. Such inflow rates are low enough to ensure that the absorbent does not dry out.

  20. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Sevinc, A.; Savli, H.; Atmaca, H. [Gaziantep University, Gaziantep (Turkey). School of Medicine

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  1. US EPA Region 9 carbon monoxide designated areas

    Data.gov (United States)

    U.S. Environmental Protection Agency — Polygon Feature class of Nonattainment Areas for Carbon Monoxide. Nonattainment areas are geographic areas which have not met National Ambient Air Quality Standards...

  2. Carbon monoxide poisoning in the United Arab Emirates.

    Science.gov (United States)

    Al Kaabi, Juma M; Wheatley, Andrew D; Barss, Peter; Al Shamsi, Mariam; Lababidi, Anis; Mushtaq, Ahmed

    2011-01-01

    Carbon monoxide (CO) poisoning is rare in the Arabian Peninsula and occurs almost exclusively during the winter months. Knowledge and perception of the hazards of carbon monoxide is limited. Migrant workers from warm climates appear particularly at risk. We investigated 46 cases of carbon monoxide poisoning presenting at emergency departments from 2007-2009 of the two main hospitals in Al Ain city, United Arab Emirates. Interviews, hospital records, and administered questionnaires were used to collect the data. Among the 46 cases investigated, 24 (52%) were males. Foreign nationals compromised 80% of the cases and the incidence was 3.1 cases per 100,000 residents per year. Burning charcoal in poorly ventilated residences was the predominant source of the carbon monoxide poisoning. Almost all cases (98%) were admitted during the winter months, most in the early morning hours. Carboxyhaemoglobin (COHb) was significantly increased in cases with loss of consciousness and depressed consciousness. There were no reported fatalities.

  3. Same Exposure, Various Clinical Pictures: The Carbon Monoxide Enigma

    Directory of Open Access Journals (Sweden)

    Musa Salmanoglu

    2013-02-01

    Full Text Available -Children and adolescents exposed to the same source of carbon monoxide have been shown to demonstrate different clinical pictures (1,2. The same condition probably may be extrapolated between children with varying ages and hence lung surface areas. Smaller children will receive larger doses of carbon monoxide, because they have greater lung surface area/body weight ratios and increased minute volumes/weight ratios. As carbon monoxide accumulation is expected to be more significant nearer to the ground, another explanation for varying clinical pictures in poisoning events may be the different level of sleeping positions of the casualties. Herein, we report a cluster poisoning of carbon monoxide affecting 5 children from the same family at the same time but in different clinical pictures. [TAF Prev Med Bull 2013; 12(1.000: 118-118

  4. Acoustic performance of membrane absorbers

    Science.gov (United States)

    Frommhold, W.; Fuchs, H. V.; Sheng, S.

    1994-03-01

    This paper is a report on the acoustic properties of absorbing elements, which consist of metal membranes and show good sound absorption at low and medium frequencies over more than one octave. The studies refer to the sound absorption coefficient and acoustic impedance at normal incidence of the sound waves. It is shown that the behavior of the absorbing element is mainly determined by a combination of Helmholtz resonance and plate resonance. The parameters of the separate resonators are determined both by theory and experiment and serve as input data for a simplified calculation model, which can be used as an auxiliary tool for designing membrane absorber silencers.

  5. An introduction to absorbent dressings.

    Science.gov (United States)

    Jones, Menna Lloyd

    2014-12-01

    Exudate bathes the wound bed with a serous fluid that contains essential components that promote wound healing. However, excess exudate is often seen as a challenge for clinicians. Absorbent dressings are often used to aid in the management of exudate, with the aim of providing a moist but unmacerated environment. With so many different types of absorbent dressings available today-alongside making a holistic assessment-it is essential that clinicians also have the knowledge and skill to select the most appropriate absorbent dressing for a given patient.

  6. Broadband fast semiconductor saturable absorber.

    Science.gov (United States)

    Jacobovitz-Veselka, G R; Kellerm, U; Asom, T

    1992-12-15

    Kerr lens mode-locked (KLM) solid-state lasers are typically not self-starting. We address this problem by introducing a broadband semiconductor saturable absorber that could be used as a tunable, all-solid-state, passive starting mechanism. We extend the wavelength tunability of a semiconductor saturable absorber to more than 100 nm using a band-gap-engineered low-temperature molecular-beam-epitaxy (MBE)-grown bulk AlGaAs semiconductor saturable absorber in which the absorption edge of the saturable absorber has been artificially broadened by continuously reducing the Al concentration during the MBE growth. We demonstrate its tunability and its feasibility as a starting mechanism for KLM with a picosecond resonant passive mode-locked Ti:sapphire laser. The extension to femtosecond KLM lasers has been discussed previously.

  7. Spontaneous emission and absorber theory

    Science.gov (United States)

    Pegg, David T.

    1997-01-01

    One of the long term interests of George Series was the construction of a theory of spontaneous emission which does not involve field quantisation. His approach was written in terms of atomic operators only and he drew a parallel with the Wheeler-Feynman absorber theory of radiation. By making a particular extra postulate, he was able to obtain the correct spontaneous emission rate and the Lamb shift reasonably simply and directly. An examination of his approach indicates that this postulate is physically reasonable and the need for it arises because quantisation in his theory occurs after the response of the absorber has been accounted for by means of the radiative reaction field. We review briefly an alternative absorber theory approach to spontaneous emission based on the direct action between the emitting atom and a quantised absorber, and outline some applications to more recent effects of interest in quantum optics.

  8. Guided tissue regeneration. Absorbable barriers.

    Science.gov (United States)

    Wang, H L; MacNeil, R L

    1998-07-01

    Over the past 15 years, techniques aimed at regeneration of lost periodontal tissue have become widely used and accepted in clinical practice. Among these techniques are those which use the principles of guided tissue regeneration (GTR), wherein barriers (i.e., membranes) are used to control cell and tissue repopulation of the periodontal wound. A variety of non-absorbable and absorbable barriers have been developed and used for this purpose, with a trend in recent years toward increased use of absorbable GTR materials. This article describes the evolution of absorbable barrier materials and overview materials available for clinical use today. In addition, advantages and disadvantages of these materials are discussed, as well as possible new developments in barrier-based GTR therapy.

  9. Test Facility for Volumetric Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, M.; Dibowski, G.; Pfander, M.; Sack, J. P.; Schwarzbozl, P.; Ulmer, S.

    2006-07-01

    Long-time testing of volumetric absorber modules is an inevitable measure to gain the experience and reliability required for the commercialization of the open volumetric receiver technology. While solar tower test facilities are necessary for performance measurements of complete volumetric receivers, the long-term stability of individual components can be tested in less expensive test setups. For the qualification of the aging effects of operating cycles on single elements of new absorber materials and designs, a test facility was developed and constructed in the framework of the KOSMOSOL project. In order to provide the concentrated solar radiation level, the absorber test facility is integrated into a parabolic dish system at the Plataforma Solar de Almeria (PSA) in Spain. Several new designs of ceramic absorbers were developed and tested during the last months. (Author)

  10. The absorber hypothesis of electrodynamics

    OpenAIRE

    De Luca, Jayme

    2008-01-01

    We test the absorber hypothesis of the action-at-a-distance electrodynamics for globally-bounded solutions of a finite-particle universe. We find that the absorber hypothesis forbids globally-bounded motions for a universe containing only two charged particles, otherwise the condition alone does not forbid globally-bounded motions. We discuss the implication of our results for the various forms of electrodynamics of point charges.

  11. Carbon monoxide exposure in blast furnace workers.

    Science.gov (United States)

    Lewis, S; Mason, C; Srna, J

    1992-09-01

    This study investigated the occupational exposure to carbon monoxide (CO) of a group of blast furnace workers from an integrated steelworks, compared to a control group having no significant occupational CO exposure from other areas in the same works. The study was undertaken in 1984 at Port Kembla, New South Wales. Carboxyhaemoglobin (COHb) levels before and after an eight-hour work shift were measured in 98 male steelworkers: 52 from two CO-exposed iron blast furnaces and 46 controls from production areas in the same steelworks. The sample was stratified by smoking habits. Environmental air CO levels had been found to be consistently higher on one furnace than on the other. Absorption of CO from the working environment occurred in workers on the blast furnace with higher CO levels, regardless of smoking habits. On this blast furnace, some readings of COHb levels after a workshift in nonsmokers approached the proposed Australian occupational limit of 5 per cent COHb saturation. Overall, workers with the highest occupational exposure who smoked most heavily had the highest absorption of CO over a work shift. Biological monitoring gives an accurate measure of individual worker 'dose' of CO from all sources. Both environmental monitoring and biological monitoring need to be included as part of a program for controlling occupational CO exposure.

  12. Carbon Monoxide: An Essential Signalling Molecule

    Science.gov (United States)

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  13. First-Principles Investigations on Europium Monoxide

    KAUST Repository

    Wang, Hao

    2011-05-01

    Europium monoxide is both an insulator and a Heisenberg ferromagnet (Tc=69 K). In the present thesis, the author has investigated the electronic structure of different types of EuO by density functional theory. The on-site Coulomb interaction of the localized Eu 4f and 5d electrons, which is wrongly treated in the standard generalized gradient approximation method, is found to be crucial to obtain the correct insulating ground state as observed in experiments. Our results show that the ferromagnetism is stable under pressure, both hydrostatic and uniaxial. For both types of pressure an insulator-metal transition is demonstrated. Moreover, the experimentally observed insulator-metal transition in oxygen deficient and gadolinium-doped EuO is reproduced in our calculations for impurity concentrations of 6.25% and 25%. Furthermore, a 10- layer EuO thin film is theoretically predicted to be an insulator with a narrow band gap of around 0.08 eV, while the Si/EuO interface shows metallic properties with the Si and O 2p as well as Eu 5d bands crossing the Fermi level.

  14. Chlorine Monoxide in the Antarctic Spring Stratosphere.

    Science.gov (United States)

    Jaramillo-Ayerbe, Mauricio

    1988-06-01

    A series of observations of stratospheric chlorine monoxide (ClO) were carried out during the austral springs of 1986 and 1987 in McMurdo Station, Antarctica, as part of two experimental campaigns sent to investigate the seasonal decrease in ozone over the antarctic continent (the ozone "hole"). Measurements of the vertical distribution of ClO were obtained by high resolution ground-based emission spectroscopy at 278 GHz, using the Stony Brook mm-wave receiver. They show the presence of an anomalous layer of lower stratospheric ClO which is not observed at other latitudes. This anomalous layer is centered at ~20 km altitude and exhibits a pronounced diurnal variation, reaching a maximum at midday and disappearing at night. During the period of Sep. 20-24, 1987, the lower-stratospheric ClO had a maximum volume mixing ratio of 1.8_sp{+0cdot5}{ -0cdot9} ppbv. A normal ClO layer centered at ~36 km was also observed, with concentrations and diurnal behavior similar to those seen in tropical latitudes. These findings are evidence of anomalous chlorine chemistry taking place in the lower stratosphere during the antarctic spring, and indicate that increasing anthropogenic chlorine is a prime causative agent in the formation of the ozone hole.

  15. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  16. Liquid chromatography coupled with ultraviolet absorbance detection, electrospray ionization, collision-induced dissociation and tandem mass spectrometry on a triple quadrupole for the on-line characterization of polyphenols and methylxanthines in green coffee beans.

    Science.gov (United States)

    Alonso-Salces, Rosa Maria; Guillou, Claude; Berrueta, Luis A

    2009-02-01

    Liquid chromatography coupled with a photodiode array detector, electrospray ionization, collision-induced dissociation and tandem mass spectrometry (LC-DAD/ESI-CID-MS/MS) on a triple quadrupole (QqQ) has been used to detect and characterize polyphenols and methylxanthines in green coffee beans: three phenolic acids (caffeic acid, ferulic acid and dimethoxycinnamic acid), three isomeric caffeoylquinic acids (M(r) 354), three feruloylquinic acids (M(r) 368), one p-coumaroylquinic acid (M(r) 338), three dicaffeoylquinic acids (M(r) 516), three feruloyl-caffeoylquinic acids (M(r) 530), four p-coumaroyl-caffeoylquinic acids (M(r) 500), three diferuloylquinic acids (M(r) 544), six dimethoxycinnamoyl-caffeoylquinic acids (M(r) 544), three dimethoxycinnamoyl-feruloylquinic acids (M(r) 558), six cinnamoyl-amino acid conjugates, three cinnamoyl glycosides, and three methylxanthines (caffeine, theobromine and theophylline). Dimethoxycinnamic acid, three isomers of dimethoxycinnamoyl-caffeoylquinic acids and another three of dimethoxycinnamoyl-feruloylquinic acids, as well as the three cinnamoyl glycosides, had not previously been reported in coffee beans. Structures have been assigned on the basis of the complementary information obtained from UV-visible spectra, relative hydrophobicity, scan mode MS spectra, and fragmentation patterns in MS(2) spectra (both in the positive and negative ion modes) obtained using a QqQ at different collision energies. A structure diagnosis scheme is provided for the identification of different isomers of polyphenols and methylxanthines.

  17. Post-treatments of Super Absorbent Polymer

    Institute of Scientific and Technical Information of China (English)

    LIU Song; ZHOU Xiang; XING Zhi-qi

    2002-01-01

    Properties of high absorbency and modulus (gel rength) were both needed in applications of superabsorbent polymer (SAP). Generally, the absorption characteristic and gel strength reach a crossover point for a given system. Beyond this point, a given property will show improvement at the expense of another property. To synthesize SAP with properties superior to this optimum value, further modification in the process becomes essential. In our post-treatment modification of superabsorbent polymer, neither the variety of the crosslinkers, nor their amount was found the effective factors to the polymer performance, but the liquor ratio of the treating liquid to polymer. The combination of the chemical treating and heat-treating method was also explored. But this didn't put any positive effect on SAP's properties.

  18. Carbon Absorber Retrofit Equipment (CARE)

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Eric [Neumann Systems Group, Incorporated, Colorado Springs, CO (United States)

    2015-12-23

    During Project DE-FE0007528, CARE (Carbon Absorber Retrofit Equipment), Neumann Systems Group (NSG) designed, installed and tested a 0.5MW NeuStream® carbon dioxide (CO2) capture system using the patented NeuStream® absorber equipment and concentrated (6 molal) piperazine (PZ) as the solvent at Colorado Springs Utilities’ (CSU’s) Martin Drake pulverized coal (PC) power plant. The 36 month project included design, build and test phases. The 0.5MW NeuStream® CO2 capture system was successfully tested on flue gas from both coal and natural gas combustion sources and was shown to meet project objectives. Ninety percent CO2 removal was achieved with greater than 95% CO2product purity. The absorbers tested support a 90% reduction in absorber volume compared to packed towers and with an absorber parasitic power of less than 1% when configured for operation with a 550MW coal plant. The preliminary techno-economic analysis (TEA) performed by the Energy and Environmental Research Center (EERC) predicted an over-the-fence cost of $25.73/tonne of CO2 captured from a sub-critical PC plant.

  19. Mushroom plasmonic metamaterial infrared absorbers

    Science.gov (United States)

    Ogawa, Shinpei; Fujisawa, Daisuke; Hata, Hisatoshi; Uetsuki, Mitsuharu; Misaki, Koji; Kimata, Masafumi

    2015-01-01

    There has been a considerable amount of interest in the development of various types of electromagnetic wave absorbers for use in different wavelength ranges. In particular, infrared (IR) absorbers with wavelength selectivity can be applied to advanced uncooled IR sensors, which would be capable of identifying objects through their radiation spectrum. In the present study, mushroom plasmonic metamaterial absorbers (MPMAs) for the IR wavelength region were designed and fabricated. The MPMAs consist of a periodic array of thin metal micropatches connected to a thin metal plate with narrow silicon (Si) posts. A Si post height of 200 nm was achieved by isotropic XeF2 etching of a thin Si layer sandwiched between metal plates. This fabrication procedure is relatively simple and is consistent with complementary metal oxide semiconductor technology. The absorption spectra of the fabricated MPMAs were experimentally measured. In addition, theoretical calculations of their absorption properties were conducted using rigorous coupled wave analysis. Both the calculated and measured absorbance results demonstrated that these MPMAs can realize strong selective absorption at wavelengths beyond the period of the array by varying the micropatch width. Absorbance values greater than 90% were achieved. Dual- or single-mode absorption can also be selected by varying the width of the Si posts. Pixel structures using such MPMAs could be used as high responsivity, high resolution and fast uncooled IR sensors.

  20. Mushroom plasmonic metamaterial infrared absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Shinpei, E-mail: Ogawa.Shimpei@eb.MitsubishiElectric.co.jp; Fujisawa, Daisuke; Hata, Hisatoshi; Uetsuki, Mitsuharu; Misaki, Koji [Advanced Technology R and D Center, Mitsubishi Electric Corporation, 8-1-1 Tsukaguchi-Honmachi, Amagasaki, Hyogo 661-8661 (Japan); Kimata, Masafumi [College of Science and Engineering, Ritsumeikan University, 1-1-1 Noji-higashi, Kusatsu, Shiga 525-8577 (Japan)

    2015-01-26

    There has been a considerable amount of interest in the development of various types of electromagnetic wave absorbers for use in different wavelength ranges. In particular, infrared (IR) absorbers with wavelength selectivity can be applied to advanced uncooled IR sensors, which would be capable of identifying objects through their radiation spectrum. In the present study, mushroom plasmonic metamaterial absorbers (MPMAs) for the IR wavelength region were designed and fabricated. The MPMAs consist of a periodic array of thin metal micropatches connected to a thin metal plate with narrow silicon (Si) posts. A Si post height of 200 nm was achieved by isotropic XeF{sub 2} etching of a thin Si layer sandwiched between metal plates. This fabrication procedure is relatively simple and is consistent with complementary metal oxide semiconductor technology. The absorption spectra of the fabricated MPMAs were experimentally measured. In addition, theoretical calculations of their absorption properties were conducted using rigorous coupled wave analysis. Both the calculated and measured absorbance results demonstrated that these MPMAs can realize strong selective absorption at wavelengths beyond the period of the array by varying the micropatch width. Absorbance values greater than 90% were achieved. Dual- or single-mode absorption can also be selected by varying the width of the Si posts. Pixel structures using such MPMAs could be used as high responsivity, high resolution and fast uncooled IR sensors.

  1. Ultrahigh-performance liquid chromatography-ultraviolet absorbance detection-high-resolution-mass spectrometry combined with automated data processing for studying the kinetics of oxidative thermal degradation of thyroxine in the solid state.

    Science.gov (United States)

    Neu, Volker; Bielow, Chris; Reinert, Knut; Huber, Christian G

    2014-12-01

    Levothyroxine as active pharmaceutical ingredient of formulations used for the treatment of hypothyroidism is distributed worldwide and taken by millions of people. An important issue in terms of compound stability is its capability to react with ambient oxygen, especially in case of long term compound storage at elevated temperature. In this study we demonstrate that ultrahigh-performance liquid chromatography coupled to UV spectrometry and high-resolution mass spectrometry (UHPLC-UV-HRMS) represent very useful approaches to investigate the influence of ambient oxygen on the degradation kinetics of levothyroxine in the solid state at enhanced degradation conditions. Moreover, the impurity pattern of oxidative degradation of levothyroxine is elucidated and classified with respect to degradation kinetics at different oxygen levels. Kinetic analysis of thyroxine bulk material at 100 °C reveals bi-phasic degradation kinetics with a distinct change in degradation phases dependent on the availability of oxygen. The results clearly show that contact of the bulk material to ambient oxygen is a key factor for fast compound degradation. Furthermore, the combination of time-resolved HRMS data and automated data processing is shown to allow insights into the kinetics and mechanism of impurity formation on individual compound basis. By comparing degradation profiles, four main classes of profiles linked to reaction pathways of thyroxine degradation were identifiable. Finally, we show the capability of automated data processing for the matching of different stressing conditions, in order to extract information about mechanistic similarities. As a result, degradation kinetics is influenced by factors like availability of oxygen, stressing time, or stressing temperature, while the degradation mechanisms appear to be conserved.

  2. High temperature thermodynamics and vaporization of stoichiometric titanium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Sheldon, R.I.; Gilles, P.W.

    1976-08-17

    Three vaporization experiments were performed on samples of nearly stoichiometric titanium monoxide. Two experiments were constant temperature experiments (1806/sup 0/K) designed to measure the equilibrium vapor pressures of Ti(g) and TiO(g). In one experiment titanium monoxide was vaporized from a tungsten Knudsen effusion cell; the vapor was collected on a water cooled quartz cap surrounding the cell; and the total amount of titanium deposited on the cap was analyzed colorimetrically. In the second constant temperature experiment (1806/sup 0/K) the vapor composition in equilibrium with nearly stoichiometric titanium monoxide was measured mass spectrometrically. The mass spectrometer results were used to apportion the total titanium collected in the first experiment to Ti(g) and TiO(g). In the third experiment the temperature dependence of the ions Ti/sup +/(48) and TiO(64) was measured spectrometrically. The results obtained in this work are compared with published thermodynamic properties of the titanium oxygen system, and indicate the standard free energy of formation of titanium monoxide obtained from the earliest calorimetric measurements yielded a result not negative enough and also oxygen pressures obtained by emf measurements for stoichiometric titanium monoxide at 1806/sup 0/K are high by a factor of 42.6. The present results are in good agreement with the thermodynamic properties reported in recently issued pages of the JANAF Thermochemical Tables.

  3. Waveform-dependent absorbing metasurfaces

    CERN Document Server

    Wakatsuchi, Hiroki; Rushton, Jeremiah J; Sievenpiper, Daniel F

    2014-01-01

    We present the first use of a waveform-dependent absorbing metasurface for high-power pulsed surface currents. The new type of nonlinear metasurface, composed of circuit elements including diodes, is capable of storing high power pulse energy to dissipate it between pulses, while allowing propagation of small signals. Interestingly, the absorbing performance varies for high power pulses but not for high power continuous waves (CWs), since the capacitors used are fully charged up. Thus, the waveform dependence enables us to distinguish various signal types (i.e. CW or pulse) even at the same frequency, which potentially creates new kinds of microwave technologies and applications.

  4. Study of an electroacoustic absorber

    OpenAIRE

    Rodríguez de Antonio, Javier

    2008-01-01

    El problema de la atenuación del ruido de baja frecuencia todavía persiste pese a que ha sido ampliamente estudiado. Las técnicas para absorber ruido de alta frecuencia (superior a 500 Hz), como son los materiales porosos, resonadores de Helmholtz o espumas no ofrecen resultados aceptables a bajas frecuencias. Serían necesarios volúmenes impracticables de materiales porosos para intentar absorber frecuencias menores a 500 Hz, y lo mismo ocurre con los resonadores de Helmholtz. Esta ineficacia...

  5. Tests of absorbents and solidification techniques for oil wastes

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M.; MacKenzie, D. R.

    1983-11-01

    A representative of each of six classes of commonly used adsorbents was chosen for a series of tests. After reviewing ASTM and other related standard tests, uncomplicated procedures were developed for carrying out specific tests to determine absorbency for simulated oil waste and for water, under static and simulated transportation (repetitive shock) conditions. The tests were then applied to the six representative absorbents. Solidification tests were performed using these absorbents saturated with oil and loaded to 50% of saturation. The binders used were Portland I cement and Delaware Custom Material (DCM) cement shale silicate. Samples were checked for proper set, and the amounts of free liquid were measured. Another series of tests was performed on samples of simulated oil waste without absorbent, using Portland cement and DCM cement shale silicate. Samples were checked for proper set, free liquid was measured, and compressive strengths were determined. The state-of-the-art parameters were identified which satisfy NRC disposal criteria for solidified radioactive waste. The literature was reviewed for alternative methods of managing oil wastes. Conclusions are drawn on the relative utility of the various methods. 17 references, 3 tables.

  6. A Fluidically Tunable Metasurface Absorber for Flexible Large-Scale Wireless Ethanol Sensor Applications

    Science.gov (United States)

    Kim, Hyung Ki; Lee, Dongju; Lim, Sungjoon

    2016-01-01

    In this paper, a novel flexible tunable metasurface absorber is proposed for large-scale remote ethanol sensor applications. The proposed metasurface absorber consists of periodic split-ring-cross resonators (SRCRs) and microfluidic channels. The SRCR patterns are inkjet-printed on paper using silver nanoparticle inks. The microfluidic channels are laser-etched on polydimethylsiloxane (PDMS) material. The proposed absorber can detect changes in the effective permittivity for different liquids. Therefore, the absorber can be used for a remote chemical sensor by detecting changes in the resonant frequencies. The performance of the proposed absorber is demonstrated with full-wave simulation and measurement results. The experimental results show the resonant frequency increases from 8.9 GHz to 10.04 GHz when the concentration of ethanol is changed from 0% to 100%. In addition, the proposed absorber shows linear frequency shift from 20% to 80% of the different concentrations of ethanol. PMID:27509498

  7. Pharmacokinetics screening for multi-components absorbed in the rat plasma after oral administration of traditional Chinese medicine Flos Lonicerae Japonicae-Fructus Forsythiae herb couple by sequential negative and positive ionization ultra-high-performance liquid chromatography/tandem triple quadrupole mass spectrometric detection.

    Science.gov (United States)

    Zhou, Wei; Tam, Kin Y; Meng, Minxin; Shan, Jinjun; Wang, Shouchuan; Ju, Wenzheng; Cai, Baochang; Di, Liuqing

    2015-01-01

    The current study aims to investigate the pharmacokinetics of multi-components (caffeic acid, quinic acid, genistein, luteolin, quercetin, neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, arctigenin, genistin, luteoloside, astragalin, hyperoside, isoquercitrin, 3,5-dicaffeoylquinic acid, 3,4-dicaffeoylquinic acid, rutin, loganin, pinoresinol-β-d-glucoside, phillyrin, isoforsythoside, forsythoside A and forsythoside B) following oral administration of Flos Lonicerae Japonicae-Fructus Forsythiae herb couple in rats. A rapid and sensitive UPLC-ESI-MS/MS with sequential positive and negative ionization modes was developed to determine the 23 absorbed ingredients using one sample preparation combined with three chromatographic conditions in rat plasma. After mixing with internal standard (IS) (tinidazole and chloramphenicol), samples were pretreated by liquid-liquid extraction (LLE) with n-butyl alcohol/ethyl acetate (1:1, v/v). The separations for pinoresinol-β-d-glucoside, phillyrin, isoforsythoside, forsythoside A and forsythoside B were performed on an ACQUITY UPLC BEH C18 column (100mm×2.1mm, 1.7μm) with acetonitrile/methanol (4:1, v/v)-water as mobile phase. For analyzing quinic acid, an ACQUITY UPLC HSS T3 column (100mm×2.1mm, 1.8μm) was applied with acetonitrile/methanol (4:1, v/v)-0.01% formic acid as mobile phase after dilution up to 25-fold. The same column was applied to the other components with acetonitrile/methanol (4:1, v/v)-0.4% formic acid as mobile phase. The method validation results demonstrated that the proposed method was sensitive, specific and reliable, which was successfully applied to the pharmacokinetic study of the multi-components after oral administration of Flos Lonicerae Japonicae-Fructus Forsythiae herb couple.

  8. Oil and fat absorbing polymers

    Science.gov (United States)

    Marsh, H. E., Jr. (Inventor)

    1977-01-01

    A method is described for forming a solid network polymer having a minimal amount of crosslinking for use in absorbing fats and oils. The polymer remains solid at a swelling ratio in oil or fat of at least ten and provides an oil absorption greater than 900 weight percent.

  9. Bioresorbable polymeric scaffolds for coronary revascularization: Lessons learnt from ABSORB III, ABSORB China, and ABSORB Japan.

    Science.gov (United States)

    Gogas, Bill D; King, Spencer B; Samady, Habib

    2015-01-01

    Bioresorbable polymers and biocorrodible metals are the latest developments in biodegradable materials used in interventional cardiology for the mechanical treatment of coronary atherosclerosis. Poly-L-lactic acid is the most frequently used bioresorbable polymer and initial evidence of feasibility, efficacy and clinical safety following deployment of polymer-based platforms was gained after completion of the first-in-man longitudinal ABSORB registries, Cohorts A and B and ABSORB Extend. In these studies, the biologic interaction of the first-generation Absorb Bioresorbable Vascular Scaffold (BVS) (Abbott Vascular, SC, Calif., US) with the underlying vascular tissue was evaluated in vivo with multiple imaging modalities such as intravascular ultrasound (IVUS), virtual histology-IVUS, IVUS-palpography, optical coherence tomography as well as ex vivo with coronary computed tomography. Efficacy measures following this in vivo multi-imaging assessment as well as clinical safety were comparable with current generation drug-eluting stents (DES) (Abbott Vascular, SC, Calif., US) in non-complex lesions over a 3-year follow-up. Furthermore, novel properties of functional and anatomic restoration of the vessel wall during the late phases of resorption and vascular healing were observed transforming the field of mechanical treatment of atherosclerosis from delivering only acute revascularization to additionally enable late repair and subsequent restoration of a more physiologic underlying vascular tissue. Despite the sufficient evidence and the subsequent Conformité Européenne mark approval of the first fully biodegradable scaffold (Absorb BVS) in 2012 for revascularizing non-complex lesions, the paucity of randomized comparisons of fully bioresorbable scaffolds (BRS) with metallic DES in a "real-world" clinical setting raised controversies among the interventional community for the merit of these technologies. Only recently, results from international large

  10. [Massive poisoning with carbon monoxide: an update from a case].

    Science.gov (United States)

    Díaz, Mariano; Crapanzano, Gabriel; Cabrerizo, Silvia; Aichele, Cristina; Deurtiaga, Alejandra; Vallejos, Yamila

    2017-02-01

    Carbon monoxide is known as the "silent murderer" because it is a colorless and odorless gas. According to these characteristics, toxicity goes unnoticed which makes the diagnosis difficult. In most cases, the cold periods and group poisoning make suspect its presence because inappropriate heat both in home or public environments. Our goal is to inform about a mass carbon monoxide poisoning in a children's parties room using a combustion source installed, not for the purpose of heating, but as a supply of light (generator), emphasizing that it can occur in any time of the year.

  11. Structural and magnetic properties of mechanochemically synthesized nanocrystalline titanium monoxide

    Directory of Open Access Journals (Sweden)

    Barudžija Tanja

    2012-01-01

    Full Text Available Nano-sized titanium monoxide (TiO powder was prepared by mechanochemical synthesis. A mixture of commercial Ti and TiO2 (rutile powders with the molar ratio of 1:1 was milled in a planetary ball mill for 5, 10, 20, 30 and 60 min under argon atmosphere. The final single-phase titanium monoxide sample was characterized by X-ray diffraction (XRD, magnetic measurements using a superconducting quantum interference device magnetometer (SQUID and thermogravimetric analysis (TGA. The temperature dependency of the magnetic susceptibility is characterized by significant contribution of Pauli paramagnetism due to conduction electrons.

  12. Observation of black carbon, ozone and carbon monoxide in the Kali Gandaki Valley Nepal

    Science.gov (United States)

    Dhungel, S.; Panday, A. K.; Kathayat, B.

    2014-12-01

    The increased melting of snow and ice in the arctic and the Himalaya is a growing concern for all of the earth's population. Deposition of black carbon (BC) on the snow and ice surface accelerates melting by absorbing the radiative energy and directly transferring all that energy onto the underlying surface. During pre-monsoon season, satellite images show a thick layer of haze covering the Indo-Gangetic plain (IGP) and the Himalayan foothills. Sub-micron particles are transported to the Himalaya from the IGP predominantly driven by the thermal valley wind system. The Himalayas consist of some of the tallest mountain ranges in the world, over 8000m tall that reach the stratosphere. The Kali Gandaki Valley in Nepal is one of the deepest gorges in the world, and has some of the highest up-valley winds in the world. It is also one of the most open connecting points for air from IGP to reach the Tibetan Plateau. In 2010 the University of Virginia, in collaboration with ICIMOD and Nepal Wireless, established an atmospheric research station in Jomsom, Nepal (28.78N, 83.42E, 2900 m.a.s.l.) half-way along the Kali Gandaki valley. The station is equipped to measure black carbon (BC), carbon monoxide (CO), and ozone concentrations. It also has an automated weather station, a filter sampler, and a NASA Aeronet Sunphotometer. Here we present our observations of black carbon, ozone, carbon monoxide at Jomsom to show the diurnal and seasonal variability of the pollutants. The results show diurnal patterns in the concentration of these pollutants and also episodes of high pollutant transport along the valley. These transport episodes are more common during the pre-monsoon season which indicates that deep mountain valleys like the Kali Gandaki valley facilitate the transport of pollutants and thus promote snow and glacial melting.

  13. Carbon Monoxide Distribution over Peninsular Malaysia from the Atmospheric Infrared Sounder (AIRS)

    Science.gov (United States)

    Rajab, Jaso M.; MatJafri, M. Z.; Lim, H. S.; Abdullah, K.

    2009-07-01

    The Atmospheric Infrared Sounder (AIRS) onboard NASA's Aqua satellite. It daily coverage of ˜70% of the planet represents a significant evolutionary advance in satellite traces gas remote sensing. AIRS, the part of a large international investment to upgrade the operational meteorological satellite systems, is first of the new generation of meteorological advanced sounders for operational and research use, Providing New Insights into Weather and Climate for the 21st Century. Carbon monoxide (CO) is a ubiquitous, an indoor and outdoor air pollutant, is not a significant greenhouse gas as it absorbs little infrared radiation from the Earth. However, it does have an influence on oxidization in the atmosphere through interaction with hydroxyl radicals (OH), which also react with methane, halocarbons and tropospheric ozone. It produced by the incomplete combustion of fossil fuels and biomass burning, and that it has a role as a smog. The aim of this investigation is to study the (CO) carbon monoxide distribution over Peninsular Malaysia. The land use map of the Peninsular Malaysia was conducted by using CO total column amount, obtained from AIRS data, the map & data was processed and analyzed by using Photoshop & SigmaPlot 11.0 programs and compared for timing of various (day time) (28 August 2005 & 29 August 2007) for both direct comparison and the comparison using the same a priori profile, the CO concentrations in 28/8/2005 higher. The CO maps were generated using Kriging Interpolation technique. This interpolation technique produced high correlation coefficient, R2 and low root mean square error, RMS for CO. This study provided useful information for influence change of CO concentration on varies temperature.

  14. Treatability study of absorbent polymer waste form for mixed waste treatment

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, S. D.; Lehto, M. A.; Stewart, N. A.; Croft, A. D.; Kern, P. W.

    2000-02-10

    A treatability study was performed to develop and characterize an absorbent polymer waste form for application to low level (LLW) and mixed low level (MLLW) aqueous wastes at Argonne National Laboratory-West (ANL-W). In this study absorbent polymers proved effective at immobilizing aqueous liquid wastes in order to meet Land Disposal Restrictions for subsurface waste disposal. Treatment of aqueous waste with absorbent polymers provides an alternative to liquid waste solidification via high-shear mixing with clays and cements. Significant advantages of absorbent polymer use over clays and cements include ease of operations and waste volume minimization. Absorbent polymers do not require high-shear mixing as do clays and cements. Granulated absorbent polymer is poured into aqueous solutions and forms a gel which passes the paint filter test as a non-liquid. Pouring versus mixing of a solidification agent not only eliminates the need for a mixing station, but also lessens exposure to personnel and the potential for spread of contamination from treatment of radioactive wastes. Waste minimization is achieved as significantly less mass addition and volume increase is required of and results from absorbent polymer use than that of clays and cements. Operational ease and waste minimization translate into overall cost savings for LLW and MLLW treatment.

  15. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  16. The Effects of Low Level Prenatal Carbon Monoxide on Neocortical Development

    Science.gov (United States)

    2010-06-02

    378.1958). Ginsberg MD, Myers RE (Fetal brain damage following maternal carbon monoxide intoxication: an experimental study. Acta obstetricia et...monoxide production and blood loss at delivery. Acta obstetricia et gynecologica Scandinavica 48:362-370.1969). Longo LD (Carbon monoxide in the

  17. Insight into magnetorheological shock absorbers

    CERN Document Server

    Gołdasz, Janusz

    2015-01-01

    This book deals with magnetorheological fluid theory, modeling and applications of automotive magnetorheological dampers. On the theoretical side a review of MR fluid compositions and key factors affecting the characteristics of these fluids is followed by a description of existing applications in the area of vibration isolation and flow-mode shock absorbers in particular. As a majority of existing magnetorheological devices operates in a so-called flow mode a critical review is carried out in that regard. Specifically, the authors highlight common configurations of flow-mode magnetorheological shock absorbers, or so-called MR dampers that have been considered by the automotive industry for controlled chassis applications. The authors focus on single-tube dampers utilizing a piston assembly with one coil or multiple coils and at least one annular flow channel in the piston.

  18. Carbon Monoxide Poisoning - Multiple Languages: MedlinePlus

    Science.gov (United States)

    ... sharing features on this page, please enable JavaScript. Amharic (amarunya) Arabic (العربية) Chinese - Traditional (繁體中文) French (français) ... Kiswahili) Tagalog (Tagalog) Tigrinya (tigrinya) Vietnamese (Tiếng Việt) Amharic (amarunya) Prevention Guidelines: You Can Prevent Carbon Monoxide ...

  19. Pathways and bioenergetics of anaerobic carbon monoxide fermentation

    NARCIS (Netherlands)

    Diender, Martijn; Stams, Fons; Machado de Sousa, Diana

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the poten

  20. UV-induced carbon monoxide emission from living vegetation

    DEFF Research Database (Denmark)

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2013-01-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop...

  1. Study on Response Time of SPE Carbon Monoxide Sensor

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The influence of structural design and the parameters of the working electrode on the response time of a solid polymer electrolyte (SPE) carbon monoxide sensor has been studied. Results show that the response time is mainly determined by the RC time constant of the catalyst layer and also related with the working electrode potential.

  2. Carbon monoxide : A quantitative tracer for fossil fuel CO2?

    NARCIS (Netherlands)

    Gamnitzer, Ulrike; Karstens, Ute; Kromer, Bernd; Neubert, Rolf E. M.; Meijer, Harro A. J.; Schroeder, Hartwig; Levin, Ingeborg

    2006-01-01

    Carbon monoxide (CO), carbon dioxide (CO2), and radiocarbon ((CO2)-C-14) measurements have been made in Heidelberg from 2001 to 2004 in order to determine the regional fossil fuel CO2 component and to investigate the application of CO as a quantitative tracer for fossil fuel CO2 (CO2(foss)). The obs

  3. Hydrogen, carbon monoxide, and methane in the marine environment

    OpenAIRE

    Bullister, John Logan

    1980-01-01

    EXTRACT (SEE PDF FOR FULL ABSTRACT): The horizontal and vertical distribution of three dissolved trace gases, namely molecular hydrogen, carbon monoxide, and methane, was measured in coastal and oceanic areas. Atmospheric concentrations of these gases were measured both at locations influenced by nearby human activity, and in areas far removed from these inputs.

  4. Carbon monoxide poisoning mimicking long-QT induced syncope

    NARCIS (Netherlands)

    I.M. Onvlee-Dekker (Irene); A.C.H. de Vries (Andrica); A.D.J. ten Harkel (Arend)

    2007-01-01

    textabstractCarbon monoxide (CO)poisoning is a rare cause of QT prolongation, and is therefore easily missed. The case of a patient with unexplained syncope and QT prologation on the electrocardiogram that turned out to be related to CO poisoning is reported here. In patients with QT prolongation,

  5. Optimization of Treatment Policy for Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    R. N. Akalayev

    2012-01-01

    Full Text Available Objective: to evaluate the efficiency of combination use of hyperbaric oxygenation, succinate-containing solutions, and anti-edematous agents in patients with acute carbon monoxide poisoning. Subjects and methods. The results of treatment were analyzed in 32 patients admitted in 2009—2011 for severe acute carbon monoxide poisoning and a Glasgow coma score of 6—8. The patients were divided into 2 groups: 1 patients whose combination therapy involved hyperbaric oxygenation, Succinasol infusions, and L-lysine-aescinate injections; 2 those who received traditional therapy. All the patients underwent complex clinical, laboratory, and neurophysiologic examinations. Results. Just 24 hours after the combination use of Succinasol and L-lysine-aescinate, Group I patients were observed to have substantially reduced lactate, the content of the latter approached the normal value following 48 hours, which was much below the values in the control group. The similar pattern was observed when endogenous intoxication parameters were examined. During the performed therapy, the level of consciousness and that of intellect according to the MMSE and FAB scales were restored more rapidly in the study group patients than in Group 2. Conclusion. The combination use of hyperbaric oxygenation, the succinate-containing solution Succinasol, and the anti-edematous agent L-lysine-aescinate considerably enhances the efficiency of intensive therapy for acute carbon monoxide poisoning. Key words: carbon monoxide, toxic hypoxic encephalopathy, combination therapy, hyperbaric oxygenation, succinic acid, L-lysine-aescinate.

  6. Carbon Monoxide Accumulation in the Extravehicular Mobility Unit

    Science.gov (United States)

    Conkin, J.; Norcrosss, J. R.; Alexander, D. J.; Sanders, R. W.; Makowski, M. S.

    2016-01-01

    Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 ?moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO

  7. Optimum thickness of Mossbauer absorber

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    If recoilless fraction fa is available, the optimum absorber thickness dopt can be calculated by maximizing the signal to noise ratio or Q factor. In this work,an approach presented is to get experimental Qexp as a function of the thickness, and then fitting Qexp by its theoretical expression gives fa value. At last the dopt value is deduced from a maximum on the fitted curve. In such a way, thicknesses of six specimens with quadrupole or magnetic hyperfine splitting were optimized.

  8. Liquids and liquid mixtures

    CERN Document Server

    Rowlinson, J S; Baldwin, J E; Buckingham, A D; Danishefsky, S

    2013-01-01

    Liquids and Liquid Mixtures, Third Edition explores the equilibrium properties of liquids and liquid mixtures and relates them to the properties of the constituent molecules using the methods of statistical thermodynamics. Topics covered include the critical state, fluid mixtures at high pressures, and the statistical thermodynamics of fluids and mixtures. This book consists of eight chapters and begins with an overview of the liquid state and the thermodynamic properties of liquids and liquid mixtures, including vapor pressure and heat capacities. The discussion then turns to the thermodynami

  9. Plasmonic titanium nitride nanostructures for perfect absorbers

    DEFF Research Database (Denmark)

    Guler, Urcan; Li, Wen-Wei; Kinsey, Nathaniel

    2013-01-01

    We propose a metamaterial based perfect absorber in the visible region, and investigate the performance of titanium nitride as an alternative plasmonic material. Numerical and experimental results reveal that titanium nitride performs better than gold as a plasmonic absorbing material...

  10. Remarks on Wheeler-Feynman absorber theory

    OpenAIRE

    Gründler, Gerold

    2014-01-01

    The derivation of absorber theory is outlined in very detail. Absorber theory is based on classical action-at-a-distance electrodynamics, but it deviates from that theory at a crucial point. It is shown that (a) absorber theory cannot achieve any of it's essential results without this deviation, and that (b) this deviation restricts the application range of absorber theory to stationary radiation processes. Furthermore an error which crept into Wheeler's and Feynman's interpretation of their ...

  11. Synchrotron radiation absorber for high density loads

    Science.gov (United States)

    Anashin, V. V.; Kuzminych, V. S.; Trakhtenberg, E. M.; Zholents, A. A.

    1991-10-01

    A design of a special synchrotron radiation absorber for the storage ring VEPP-4M is presented. The density of the synchrotron radiation power on the absorber surface is up to 500 W/mm 2. The absorber is made from a beryllium plate, brazed inside to the copper vacuum chamber, which is intensively water-cooled from outside.

  12. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes;

    2010-01-01

    Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...... processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures...

  13. A diagram for defined solar radiation absorbed per unit area of flat plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Tekin, Y.; Altuntop, N. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States); Cengel, Y.A. [Nevada University, Dept. Mechanical Engineering, Reno, NV (United States)

    2000-07-01

    In Erciyes University, the Solar House (28.75 m{sup 2}) is heated from the floor by using flat plate liquid solar collectors. Required solar radiation for heating and heat losses are calculated. In this work, the required calculations for Erciyes Solar House were generalized and required calculation were done to evaluate absorbed solar radiation per unit surface of the flat plate liquid collector. At the end, three generalized diagrams for nine different months are obtained using obtained numerical values. The goal of preparing diagrams is to determine absorbed solar radiation per unit surface area of flat plate liquid collector at any instant at any latitude, In this work, the diagram is explained by means of sample calculations for November. This diagram was prepared to find out absorbed solar radiation per unit area of black surface collector by means obtained equations. With this diagram, all instant solar radiation can be evaluated in 19 steps. (authors)

  14. Piezooptic effect of absorbing environment

    Directory of Open Access Journals (Sweden)

    Ю. А. Рудяк

    2013-07-01

    Full Text Available Application of piezooptic effect of absorbing environment for the definition of the parameter of stress deformation state was examined. The analysis of dielectric permeability tensor of imaginary parts was done. It is shown that changes in the real part dielectric permeability tensor mainly the indicator of fracture was fixed by means of mechanics interference methods and the changes in the imaginary part (α – real rate of absorption can be measured by means of analysis of light absorption and thus stress deformation state can be determined

  15. Porcelain enamel neutron absorbing material

    Science.gov (United States)

    Iverson, Daniel C.

    1990-01-01

    A porcelain enamel composition as a neutron absorbing material can be prepared of a major proportion by weight of a cadmium compound and a minor proportion of compounds of boron, lithium and silicon. These compounds in the form of a porcelain enamel coating or layer on several alloys has been found to be particularly effective in enhancing the nuclear safety of equipment for use in the processing and storage of fissile material. The composition of the porcelain enamel coating can be tailored to match the coefficient of thermal expansion of the equipment to be coated and excellent coating adhesion can be achieved.

  16. Carbon dioxide absorbents for rebreather diving.

    Science.gov (United States)

    Pennefather, John

    2016-09-01

    Firstly I would like to thank SPUMS members for making me a Life Member of SPUMS; I was surprised and greatly honoured by the award. I also want to confirm and expand on the findings on carbon dioxide absorbents reported by David Harvey et al. For about 35 years, I was the main player in deciding which absorbent went into Australian Navy and Army diving sets. On several occasions, suppliers of absorbents to the anaesthesia market tried to supply the Australian military market. On no occasion did they provide absorbent that came close to the minimum absorbent capacity required, generally being 30-40% less efficient than diving-grade absorbents. Because I regard lives as being more important than any likely dollar saving, the best absorbent was always selected unless two suppliers provided samples with the same absorbent capacity. On almost every occasion, there was a clear winner and cost was never considered. I suggest the same argument for the best absorbent should be used by members and their friends who dive using rebreather sets. I make this point because of my findings on a set that was brought to me after the death of its owner. The absorbent was not the type or grain size recommended by the manufacturer of the set and did not resemble any of the diving grade absorbents I knew of. I suspected by its appearance that it was anaesthetic grade absorbent. When I tested the set, the absorbent system failed very quickly so it is likely that carbon dioxide toxicity contributed to his death. The death was not the subject of an inquest and I have no knowledge of how the man obtained the absorbent. Possibly there was someone from an operating theatre staff who unintentionally caused their friend's death by supplying him with 'borrowed absorbent'. I make this point as I would like to discourage members from making a similar error.

  17. A polarization-independent broadband terahertz absorber

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Cheng; Zang, XiaoFei, E-mail: xfzang@usst.edu.cn, E-mail: ymzhu@usst.edu.cn; Wang, YiQiao; Chen, Lin; Cai, Bin; Zhu, YiMing, E-mail: xfzang@usst.edu.cn, E-mail: ymzhu@usst.edu.cn [Shanghai Key Laboratory of Modern Optical System and Engineering Research Center of Optical Instrument and System, Ministry of Education, University of Shanghai for Science and Technology, Shanghai 200093 (China)

    2014-07-21

    A highly efficient broadband terahertz absorber is designed, fabricated, and experimentally as well as theoretically evaluated. The absorber comprises a heavily doped silicon substrate and a well-designed two-dimensional grating. Due to the destructive interference of waves and diffraction, the absorber can achieve over 95% absorption in a broad frequency range from 1 to 2 THz and for angles of incidence from 0° to 60°. Such a terahertz absorber is also polarization-independent due to its symmetrical structure. This omnidirectional and broadband absorber have potential applications in anti-reflection coatings, imaging systems, and so on.

  18. Remarks on Wheeler-Feynman absorber theory

    CERN Document Server

    Gründler, Gerold

    2015-01-01

    The derivation of absorber theory is outlined in very detail. Absorber theory is based on classical action-at-a-distance electrodynamics, but it deviates from that theory at a crucial point. It is shown that (a) absorber theory cannot achieve any of it's essential results without this deviation, and that (b) this deviation restricts the application range of absorber theory to stationary radiation processes. Furthermore an error which crept into Wheeler's and Feynman's interpretation of their equation (19) is pointed out. These shortcomings can probably be eliminated by a quantum-theoretical formulation of absorber theory.

  19. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  20. Analysis of heat and mass transfer on helical absorber

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, O.K.; Kim, S.C.; Yun, J.H. [Korea Institute of Industrial Technology, Chonan (Korea); Lim, J.K.; Yoon, J.I. [Pukyong National University, Pusan (Korea)

    2000-11-01

    The absorption of vapor involves simultaneous heat and mass transfer in the vapor/liquid system. In this paper, a numerical study for vapor absorption process into LiBr-H{sub 2}O solution film flowing over helical absorber has been carried out. Axisymmetric cylindrical coordinate system was adopted to model the helical tube and the transport equations were solved by the finite volume method. The effects of operating conditions, such as the cooling water temperature, the system pressure, the film Reynolds number and the solution inlet concentration have been investigated in view of the absorption mass flux and the total absorption rate. The results for the temperature and concentration profiles, as well as the local absorption mass flux at the helical absorber are presented. It is shown that solution inlet concentration affected other than operation conditions for a mass flux. (author). 10 refs., 14 figs., 2 tabs.

  1. Carbon monoxide photoproduction: implications for photoreactivity of Arctic permafrost-derived soil dissolved organic matter.

    Science.gov (United States)

    Hong, Jun; Xie, Huixiang; Guo, Laodong; Song, Guisheng

    2014-08-19

    Apparent quantum yields of carbon monoxide (CO) photoproduction (AQY(CO)) for permafrost-derived soil dissolved organic matter (SDOM) from the Yukon River Basin and Alaska coast were determined to examine the dependences of AQY(CO) on temperature, ionic strength, pH, and SDOM concentration. SDOM from different locations and soil depths all exhibited similar AQY(CO) spectra irrespective of soil age. AQY(CO) increased by 68% for a 20 °C warming, decreased by 25% from ionic strength 0 to 0.7 mol L(-1), and dropped by 25-38% from pH 4 to 8. These effects combined together could reduce AQY(CO) by up to 72% when SDOM transits from terrestrial environemnts to open-ocean conditions during summer in the Arctic. A Michaelis-Menten kinetics characterized the influence of SDOM dilution on AQY(CO) with a very low substrate half-saturation concentration. Generalized global-scale relationships between AQY(CO) and salinity and absorbance demostrate that the CO-based photoreactivity of ancient permaforst SDOM is comparable to that of modern riverine DOM and that the effects of the physicochemical variables revealed here alone could account for the seaward decline of AQY(CO) observed in diverse estuarine and coastal water bodies.

  2. The complex analytical method for assessment of passive smokers' exposure to carbon monoxide.

    Science.gov (United States)

    Czogala, Jan; Goniewicz, Maciej Lukasz

    2005-01-01

    Carbon monoxide (CO) is one of the toxic constituents in tobacco smoke. The aim of the study was to evaluate a complex analytical method that allows quantification of the exposure of passive smokers to CO. The exposed volunteers were placed in the model room where portions of cigarettes (5, 10, or 15 cigarettes every 30 or 60 min over 4 h) were smoked using a homemade smoking machine. The concentrations of CO and of the ventilation marker (methane) were monitored for the duration of each experiment. CO and methane were analyzed on-line using GC-FID with methanization. Carboxyhemoglobin (COHb) was analyzed twice: just before and after the experiment. After hemolysis of a 100-microL blood sample, CO was quantitatively released by adding 10% K3[Fe(CN)6] inside a small reactor and under stable pressure transported through a microtube with an absorbing agent on a chromatography loop. The proposed analytical method allows us to quantify exposure of passive smokers by measuring the dose-effect correlation. We observed that increasing COHb levels were directly correlated with the CO concentration in the air, but were also intermediately correlated with the frequency and number of smoked cigarettes and with the ventilation coefficient.

  3. Light irradiation for treatment of acute carbon monoxide poisoning: an experimental study.

    Science.gov (United States)

    Tanaka, Taku; Kashimura, Takeshi; Ise, Marii; Lohman, Brandon D; Taira, Yasuhiko

    2016-01-01

    Because treatment modalities for carbon monoxide (CO) poisoning, especially normobaric oxygen and hyperbaric oxygen therapies, have limited effects and hyperbaric oxygen is not available at the scene where treatment is most needed, we conducted a study to determine and compare rates of carboxyhemoglobin (COHb) dissociation achieved in human in vitro blood samples under light radiation emitted at three levels of illuminance. This was done with a view toward eventual on-site application. We drew blood from 10 volunteers, prepared 10 red blood cell solutions, and subjected each solution to a CO bubbling procedure to increase the COHb saturation. Samples of each bubbled solution were then divided between 3 beakers (beakers A, B, and C) for a total of 30 beakers. The solution in each beaker was exposed to a continuous flow of oxygen at 50 mL/min, and simultaneously for a period of 15 min, the beaker A and B solutions were irradiated with light emitted at 500,000 and 100,000 lux, respectively, from a halogen light source. The beaker C solutions were exposed to room light. At 3, 6, 9, 12, and 15 min, a 50-μL sample was pipetted from each of the 30 beakers for determination of its light absorbance and the COHb dissociation rate. Under each of the experimental conditions, dissociation progressed but at different rates, and starting at 3 min, the differences in rates between conditions were significant (P poisoning.

  4. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases

    Directory of Open Access Journals (Sweden)

    A. Mishra

    2011-05-01

    Full Text Available In this review, recent works on the preferential oxidation of carbon monoxide in hydrogen rich gases for fuel cell applications are summarized. H2 is used as a fuel for polymer-electrolyte membrane fuel cell (PEMFC. It is produced by reforming of natural gas or liquid fuels followed by water gas shift reaction. The produced gas consists of H2, CO, and CO2. In which CO content is around 1%, which is highly poisonous for the Pt anode of the PEMFC so that further removal of CO is needed. Catalytic preferential oxidation of CO (CO-PROX is one of the most suitable methods of purification of H2 because of high CO conversion rate at low temperature range, which is preferable for PEMFC operating conditions. Catalysts used for COPROX are mainly noble metal based; gold based and base metal oxide catalysts among them Copper-Ceria based catalysts are the most appropriate due to its low cost, easy availability and result obtained by these catalysts are comparable with the conventional noble metal catalysts. Copyright © 2011 BCREC UNDIP. All rights reserved(Received: 22nd October 2010, Revised: 12nd January 2011, Accepted: 19th January 2011[How to Cite: A. Mishra, R. Prasad. (2011. A Review on Preferential Oxidation of Carbon Monoxide in Hydrogen Rich Gases. Bulletin of Chemical Reaction Engineering & Catalysis, 6 (1: 1-14. doi:10.9767/bcrec.6.1.191.1-14][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.1.191.1-14 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/191] | View in 

  5. Digit and letter alexia in carbon monoxide poisoning

    Institute of Scientific and Technical Information of China (English)

    Qingyu Shen; Xiaoming Rong; Rui Pan; Ying Peng; Wei Peng; Yamei Tang

    2012-01-01

    This study examined a 24-year-old patient with delayed encephalopathy, who was admitted to hospital with complaints of headache and visual impairment 1 week after acute carbon monoxide poisoning. The results of a visual field assessment, electroencephalography and head magnetic resonance imaging indicated damage to the cerebral cortex. After a 2-week treatment period, the patient had recovered from the visual impairment, but exhibited digit- and letter-reading difficulty. The Chinese aphasia battery and the number and letter battery supplement were conducted. The results revealed that the patient exhibited digit and letter alexia, while the ability to read Chinese characters was preserved. In contrast, the patient exhibited a deficit in Chinese character writing, while number and letter writing remained intact. Following treatment, reading and writing ability was improved and electroencephalographic abnormalities were ameliorated. Overall, our experimental findings demonstrated that delayed encephalopathy following acute carbon monoxide poisoning was characterized by digit and letter alexia.

  6. Catalysis of carbon monoxide methanation by deep sea manganate minerals

    Science.gov (United States)

    Cabrera, A. L.; Maple, M. B.; Arrhenius, G.

    1990-01-01

    The catalytic activity of deep sea manganese nodule minerals for the methanation of carbon monoxide was measured with a microcatalytic technique between 200 and 460 degrees C. The manganate minerals were activated at 248 degrees C by immersion into a stream of hydrogen in which pulses of carbon monoxide were injected. Activation energies for the methanation reaction and hydrogen desorption from the manganate minerals were obtained and compared with those of pure nickel. Similar energy values indicate that the activity of the nodule materials for the reaction appears to be related to the amount of reducible transition metals present in the samples (ca. 11 wt.-%). Since the activity of the nodule minerals per gram is comparable to that of pure nickel, most of the transition metal ions located between manganese oxide layers appear to be exposed and available to catalyze the reaction.

  7. Effect of carbon monoxide on plants. [Mimosa pudica

    Energy Technology Data Exchange (ETDEWEB)

    Zimmerman, P.W.; Crocker, W.; Hitchcock, A.E.

    1933-01-01

    Of 108 species of plants treated with one per cent carbon monoxide, 45 showed epinastic growth of leaves. Several species showed hyponasty which caused upward curling of leaves. Other effects included: retarded stem elongation; abnormally small new leaves; abnormal yellowing of the leaves, beginning with the oldest; abscission of leaves usually associated with yellowing; and hypertrophied tissues on stems and roots. During recovery an abnormally large number of side shoots arose from latent buds of many species. Motion pictures of Mimosa pudica showed a loss of correlation, normal equilibrium position to gravity, and sensitiveness to contact or heat stimuli; however, the leaves moved about more rapidly than those of controls. Since carbon monoxide causes growth rigor and loss of sensitiveness to external stimuli, it is here considered as an anesthetic.

  8. [Sudden unilateral sensorineural hearing loss after carbon monoxide intoxication].

    Science.gov (United States)

    Michalska-Piechowiak, Teresa; Miarzyńska, Maria; Perlik-Gattner, Irena

    2004-01-01

    A case of unilateral sensorineural hearing loss of the left ear after carbon monoxide intoxication was presented. The diagnosis was based upon an interview, medical examinations and audiometric investigations. Results of diagnostic evaluations, clinical presentation and treatment were discussed. Hearing improvement was obtained after 6 days of treatment and normal hearing returned after 14 days. Patients who suffer from CO intoxication are at risk of hearing impairment, therefore, there is a need for audiometric follow up in these patients.

  9. Pregnancy Hypertenssion and Preeclampsia in Enviromental Expossure to Carbon Monoxide

    OpenAIRE

    2008-01-01

    Introduction: In this study relationship between carbon monoxide (CO) with pregnancy induced hypertension and preeclampsia in mothers in various levels of CO pollution was evaluated. Methods: The study was carried out in three teaching hospitals and 4500 pregnant women living area divided in one low-level CO polluted and as the second level, three moderate to high polluted areas (central, south and west). The subjects, residence places were within 5 kilometers of the air pollution monitoring ...

  10. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  11. Electrochemical device for syngas and liquid fuels production

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Robert J.; Becker, William L.; Penev, Michael

    2017-04-25

    The invention relates to methods for creating high value liquid fuels such as gasoline, diesel, jet and alcohols using carbon dioxide and water as the starting raw materials and a system for using the same. These methods combine a novel solid oxide electrolytic cell (SOEC) for the efficient and clean conversion of carbon dioxide and water to hydrogen and carbon monoxide, uniquely integrated with a gas-to-liquid fuels producing method.

  12. Analysis of solar water heater with parabolic dish concentrator and conical absorber

    Science.gov (United States)

    Rajamohan, G.; Kumar, P.; Anwar, M.; Mohanraj, T.

    2017-06-01

    This research focuses on developing novel technique for a solar water heating system. The novel solar system comprises a parabolic dish concentrator, conical absorber and water heater. In this system, the conical absorber tube directly absorbs solar radiation from the sun and the parabolic dish concentrator reflects the solar radiations towards the conical absorber tube from all directions, therefore both radiations would significantly improve the thermal collector efficiency. The working fluid water is stored at the bottom of the absorber tubes. The absorber tubes get heated and increases the temperature of the working fluid inside of the absorber tube and causes the working fluid to partially evaporate. The partially vaporized working fluid moves in the upward direction due to buoyancy effect and enters the heat exchanger. When fresh water passes through the heat exchanger, temperature of the vapour decreases through heat exchange. This leads to condensation of the vapour and forms liquid phase. The working fluid returns to the bottom of the collector absorber tube by gravity. Hence, this will continue as a cyclic process inside the system. The proposed investigation shows an improvement of collector efficiency, enhanced heat transfer and a quality water heating system.

  13. Energy-Absorbing Beam Member

    Science.gov (United States)

    Littell, Justin D. (Inventor)

    2017-01-01

    An energy-absorbing (EA) beam member and having a cell core structure is positioned in an aircraft fuselage proximate to the floor of the aircraft. The cell core structure has a length oriented along a width of the fuselage, a width oriented along a length of the fuselage, and a depth extending away from the floor. The cell core structure also includes cell walls that collectively define a repeating conusoidal pattern of alternating respective larger and smaller first and second radii along the length of the cell core structure. The cell walls slope away from a direction of flight of the aircraft at a calibrated lean angle. An EA beam member may include the cell core structure and first and second plates along the length of the cell core structure on opposite edges of the cell material.

  14. Numerical simulations of quasar absorbers

    CERN Document Server

    Theuns, T

    2005-01-01

    The physical state of the intergalactic medium can be probed in great detail with the intervening absorption systems seen in quasar spectra. The properties of the Hydrogen absorbers depend on many cosmological parameters, such as the matter-power spectrum, reionisation history, ionising background and the nature of the dark matter. The spectra also contain metal lines, which can be used to constrain the star formation history and the feedback processes acting in large and small galaxies. Simulations have been instrumental in investigating to what extent these parameters can be unambiguously constrained with current and future data. This paper is meant as an introduction to this subject, and reviews techniques and methods for simulating the intergalactic medium.

  15. Warm Absorbers in Active Galactic Nuclei

    CERN Document Server

    Komossa, S

    2000-01-01

    We first provide a review of the properties of warm absorbers concentrating on what we have learned from ROSAT and ASCA. This includes dusty and dust-free warm absorbers, non-X-ray emission and absorption features of warm absorbers, and the possible warm absorber interpretation of the peculiar 1.1 keV features. We then discuss facets of warm absorbers by a more detailed investigation of individual objects: In a first part, we discuss several candidates for dusty warm absorbers. In a second part, we review and extend our earlier study of a possible relation between warm absorber and CLR in NGC 4051, and confirm that both components are of different origin (the observed coronal lines are underpredicted by the models, the warm absorber is too highly ionized). We then suggest that a potential overprediction of these lines in more lowly ionized absorbers can be avoided if these warm absorbers are dusty. In a third part, we present first results of an analysis of a deep ROSAT PSPC observation of the quasar MR2251-1...

  16. Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols.

    Science.gov (United States)

    Seuntjens, Jan; Olivares, Marina; Evans, Michael; Podgorsak, Ervin

    2005-09-01

    For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ionization chambers calibrated in terms of absorbed dose to water but irradiated in solid phantoms. Such a framework is useful when there is a desire to put dose measurements using solid phantoms on an absolute basis. Putting solid phantom measurements on an absolute basis has distinct advantages in verification measurements and quality assurance. We introduce a phantom dose conversion factor that converts a measurement made in a solid phantom and analyzed using an absorbed dose calibration protocol into absorbed dose to water under reference conditions. We provide techniques to measure and calculate the dose transfer from solid phantom to water. For an Exradin A12 ionization chamber, we measured and calculated the phantom dose conversion factor for six Solid Water phantoms and for a single Lucite phantom for photon energies between 60Co and 18 MV photons. For Solid Water of certified grade, the difference between measured and calculated factors varied between 0.0% and 0.7% with the average dose conversion factor being low by 0.4% compared with the calculation whereas for Lucite, the agreement was within 0.2% for the one phantom examined. The composition of commercial plastic phantoms and their homogeneity may not always be reproducible and consistent with assumed composition. By comparing measured and calculated phantom conversion factors, our work provides methods to verify the consistency of a given plastic for the purpose of clinical reference dosimetry.

  17. Central Diabetes Insipidus and Hyperglycemic Hyperosmolar State Following Accidental Carbon Monoxide Poisoning.

    Science.gov (United States)

    Ul Abideen, Zain; Mahmud, Syed Nayer; Rasheed, Amna; Farooq Qasim, Yusaf; Ali, Furqan

    2017-06-03

    Carbon monoxide poisoning is common and carries significant morbidity and mortality. The nervous system, particularly the brain, is frequently affected by it, owing to its high metabolic activity and oxygen requirements. Carbon monoxide damages the nervous system by both hypoxic and inflammatory mechanisms. Central diabetes insipidus is an extremely rare complication of carbon monoxide poisoning. Herein, we report the case of a young lady, who developed this complication and severe hypernatremia after accidental carbon monoxide poisoning. She also developed a hyperglycemic hyperosmolar state during the treatment for hypernatremia. To the best of our knowledge, both these entities have not been reported together in association with carbon monoxide poisoning. The purpose of this article is to emphasize the anticipation and early recognition of central diabetes insipidus in carbon monoxide poisoning. This can prevent severe hypernatremia and complications associated with its presence and treatment.

  18. Multiband Negative Permittivity Metamaterials and Absorbers

    Directory of Open Access Journals (Sweden)

    Yiran Tian

    2013-01-01

    Full Text Available Design and characteristics of multiband negative permittivity metamaterial and its absorber configuration are presented in this paper. The proposed multiband metamaterial is composed of a novel multibranch resonator which can possess four electric resonance frequencies. It is shown that, by controlling the length of the main branches of such resonator, the resonant frequencies and corresponding absorbing bands of metamaterial absorber can be shifted in a large frequency band.

  19. Multiobjective Topology Optimization of Energy Absorbing Materials

    Science.gov (United States)

    2015-08-01

    125–143 DOI 10.1007/s00158-014-1117-8 RESEARCH PAPER Multiobjective topology optimization of energy absorbing materials Raymond A. Wildman · George A...recent developments. J Multiscale Model 3(4):1–42 Qiao P, Yang M, Bobaru F (2008) Impact mechanics and high-energy absorbing materials: review . J Aerosp...ARL-RP-0533 ● AUG 2015 US Army Research Laboratory Multiobjective Topology Optimization of Energy Absorbing Materials by

  20. A Six-Fold Symmetric Metamaterial Absorber

    Directory of Open Access Journals (Sweden)

    Humberto Fernández Álvarez

    2015-04-01

    Full Text Available A novel microwave metamaterial absorber design is introduced along with its manufacturing and characterization. Significant results considering both bandwidth and angular stability are achieved. Parametric analysis and simplified equivalent circuit are provided to give an insight on the key elements influencing the absorber performance. In addition, the constitutive parameters of the effective medium model are obtained and related to the absorber resonant behavior. Moreover, a new thinner and more flexible absorber version, preserving broad bandwidth and angular insensitive performance, is simulated, and an 8 × 8 unit-cells prototype is manufactured and measured for a limited angular margin in an anechoic chamber.

  1. Nonlinear dynamic vibration absorbers with a saturation

    Science.gov (United States)

    Febbo, M.; Machado, S. P.

    2013-03-01

    The behavior of a new type of nonlinear dynamic vibration absorber is studied. A distinctive characteristic of the proposed absorber is the impossibility to extend the system to infinity. The mathematical formulation is based on a finite extensibility nonlinear elastic potential to model the saturable nonlinearity. The absorber is attached to a single degree-of-freedom linear/nonlinear oscillator subjected to a periodic external excitation. In order to solve the equations of motion and to analyze the frequency-response curves, the method of averaging is used. The performance of the FENE absorber is evaluated considering a variation of the nonlinearity of the primary system, the damping and the linearized frequency of the absorber and the mass ratio. The numerical results show that the proposed absorber has a very good efficiency when the nonlinearity of the primary system increases. When compared with a cubic nonlinear absorber, for a large nonlinearity of the primary system, the FENE absorber shows a better effectiveness for the whole studied frequency range. A complete absence of quasi-periodic oscillations is also found for an appropriate selection of the parameters of the absorber. Finally, direct integrations of the equations of motion are performed to verify the accuracy of the proposed method.

  2. Metamaterial absorber with random dendritic cells

    Science.gov (United States)

    Zhu, Weiren; Zhao, Xiaopeng

    2010-05-01

    The metamaterial absorber composed of random dendritic cells has been investigated at microwave frequencies. It is found that the absorptivities come to be weaker and the resonant frequency get red shift as the disordered states increasing, however, the random metamaterial absorber still presents high absorptivity more than 95%. The disordered structures can help understanding of the metamaterial absorber and may be employed for practical design of infrared metamaterial absorber, which may play important roles in collection of radiative heat energy and directional transfer enhancement.

  3. Synthesis of hemicellulose-acrylic acid graft copolymer super water absorbent resin by ultrasonic irradiation technology

    Directory of Open Access Journals (Sweden)

    Fangfang LIU

    2015-12-01

    Full Text Available The hemicellulose super water absorbent resin is prepared by using ultrasonic irradiation technology, with the waste liquid produced during the preparation of viscose fiber which contains a large amount of hemicellulose as raw material, acrylic acid as graft monomer, N,N’-methylene bis acrylamide (NMBA as cross linking agent, and (NH42S2O8-NaHSO3 as the redox initiation system. The synthesis conditions, structure and water absorption ability of resin are discussed. The results indicate that water absorbency of the resin is 311 g/g, the tap water absorbency is 102 g/g, the normal saline absorbency is 55 g/g, and the artificial urine absorbency is 31 g/g under the optimal synthesis conditions, so the resin has great water absorption rate and water retaining capacity. The FT-IR and SEM analysis shows that the resin with honeycomb network structure is prepared. The successfully synthesized of the resin means that the hemicellulose waste liquid can be highly effectively recycled, and it provides a kind of new raw material for the synthesis of super water absorbent resin.

  4. Carbon monoxide may be an important molecule in migraine and other headaches

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Schytz, Henrik W; Hauge, Mette K

    2014-01-01

    INTRODUCTION: Carbon monoxide was previously considered to just be a toxic gas. A wealth of recent information has, however, shown that it is also an important endogenously produced signalling molecule involved in multiple biological processes. Endogenously produced carbon monoxide may thus play...... an important role in nociceptive processing and in regulation of cerebral arterial tone. DISCUSSION: Carbon monoxide-induced headache shares many characteristics with migraine and other headaches. The mechanisms whereby carbon monoxide causes headache may include hypoxia, nitric oxide signalling and activation...

  5. Mixing ratios of carbon monoxide in the troposphere

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Steele, L.P. (Univ. of Colorado, Boulder (United States)); Tans, P.P. (NOAA, Boulder, CO (United States))

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  6. Extinction efficiencies of coated absorbing aerosols measured by cavity ring down aerosol spectrometry

    Directory of Open Access Journals (Sweden)

    E. Segre

    2008-03-01

    Full Text Available In this study, we measure the extinction efficiency at 532 nm of absorbing aerosol particles coated with a non-absorbing solid and liquid organic shell with coating thickness varying between 5 and 100 nm using cavity ring down aerosol spectrometry. For this purpose, we use nigrosin, an organic black dye, as a model absorbing core and two non-absorbing organic substances as shells, glutaric acid (GA and Di-Ethyl-Hexyl-Sebacate (DEHS. The measured behavior of the coated particles is consistent with Mie calculations of core-shell particles. Errors between measured and calculated values for nigrosin coated with GA and DEHS are between 0.5% and 10.5% and between 0.5% and 9%, respectively. However, it is evident that the calculations are in better agreement with the measured results for thinner coatings. Possible reasons for these discrepancies are discussed.

  7. Extinction efficiencies of coated absorbing aerosols measured by cavity ring down aerosol spectrometry

    Directory of Open Access Journals (Sweden)

    A. A. Riziq

    2007-12-01

    Full Text Available In this study, we measure the extinction efficiency at 532 nm of absorbing aerosol particles coated with a non-absorbing solid and liquid organic shell with coating thickness varying between 5 and 100 nm using cavity ring down aerosol spectrometry. For this purpose, we use nigrosin, an organic black dye, as a model absorbing core and two non–absorbing organic substances as shells, glutaric acid (GA and Di-Ethyl-Hexyl-Sebacate (DEHS. The measured behavior of the coated particles is consistent with Mie calculations of core-shell particles. Errors between measured and calculated values for nigrosin coated with GA and DEHS are between 0.5% and 10.5% and between 0.5% and 9%, respectively. However, it is evident that the calculations are in better agreement with the measured results for thinner coatings. Possible reasons for these discrepancies are discussed.

  8. Thermal Degradation of Lead Monoxide Filled Polymer Composite Radiation Shields

    Science.gov (United States)

    Harish, V.; Nagaiah, N.

    2011-07-01

    Lead monoxide filled Isophthalate resin particulate polymer composites were prepared with different filler concentrations and investigated for physical, thermal, mechanical and gamma radiation shielding characteristics. This paper discusses about the thermo gravimetric analysis of the composites done to understand their thermal properties especially the effect of filler concentration on the thermal stability & degradation rate of composites. Pristine polymer exhibits single stage degradation whereas filled composites exhibit two stage degradation processes. Further, the IDT values as well as degradation rates decrease with the increased filler content in the composite.

  9. Modeling of Carbon Monoxide Removal by Corona Plasma

    Institute of Scientific and Technical Information of China (English)

    FENG Jingwei; SUN Yabing; ZHAO Dayong; ZHENG Zheng; XU Yuewu; YANG Haifeng; ZHU Hongbiao; ZHOU Xiaoxia

    2009-01-01

    Modeling of carbon monoxide (CO) removal by a corona plasma was conducted in this study.The purification efficiency of CO was calculated theoretically and the factors affecting the removal of CO were analyzed.The results showed that the main removal mechanisms of CO were direct dissociation by generated high-energy electrons and indirect oxidation by generated hydroxyl radicals.The purification efficiency of CO was dependent on the plasma parameters,indoor air humidity and initial concentration of CO.Good consistency between the theoretical calculation and the experimental results was observed.

  10. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    Science.gov (United States)

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  11. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Directory of Open Access Journals (Sweden)

    Martijn eDiender

    2015-11-01

    Full Text Available Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  12. OMI Observations of Bromine Monoxide Emissions from Volcanoes

    Science.gov (United States)

    Suleiman, R. M.; Chance, K.; Liu, X.; Gonzalez Abad, G.; Kurosu, T. P.

    2016-12-01

    We analyze bromine monoxide (BrO) data from the Ozone Monitoring Instrument (OMI) for emissions from various volcanoes. We use OMI data from 2005 to 2014 to investigate BrO signatures from Galapagos, Kasatochi and Eyjafjallajökull volcanoes. Elevated signatures of BrO daily averages were found over Eyjafjallajökull. SO2 cross sections are updated in the operational BrO algorithm and their effect on the volcanic BrO signature is studied. Comparison between two different sets of SO2 cross sections is made and results still show BrO enhancement over the Eyjafjallajökull region.

  13. Studies relevant to the catalytic activation of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Ford, P.C.

    1992-06-04

    Research activity during the 1991--1992 funding period has been concerned with the following topics relevant to carbon monoxide activation. (1) Exploratory studies of water gas shift catalysts heterogenized on polystyrene based polymers. (2) Mechanistic investigation of the nucleophilic activation of CO in metal carbonyl clusters. (3) Application of fast reaction techniques to prepare and to investigate reactive organometallic intermediates relevant to the activation of hydrocarbons toward carbonylation and to the formation of carbon-carbon bonds via the migratory insertion of CO into metal alkyl bonds.

  14. Dipolar dissociation dynamics in electron collisions with carbon monoxide

    CERN Document Server

    Chakraborty, Dipayan; Nandi, Dhananjay

    2016-01-01

    Dipolar dissociation processes in the electron collisions with carbon monoxide have been studied using time of flight (TOF) mass spectroscopy in combination with the highly differential velocity slice imaging (VSI) technique. Probing ion-pair states both positive and/or negative ions may be detected. The ion yield curve of negative ions provides the threshold energy for the ion-pair production. On the other hand, the kinetic energy distributions and angular distributions of the fragment anion provide detailed dynamics of the dipolar dissociation process. Two ion-pair states have been identified based on angular distribution measurements using VSI technique.

  15. An ultrathin dual-band metamaterial absorber

    Science.gov (United States)

    Zhang, Yong; Duan, Junping; Zhang, Wendong; Wang, Wanjun; Zhang, Binzhen

    2016-10-01

    The design and preparation of an ultrathin dual-band metamaterial absorber whose resonant frequency located at radar wave (20 GHz-60 GHz) is presented in this paper. The absorber is composed of a 2-D periodic sandwich featured with two concentric annuluses. The influence on the absorber's performance produced by resonant cell's structure size and material parameters was numerically simulated and analyzed based on the standard full wave finite integration technology in CST. Laser ablation process was adopted to prepare the designed absorber on epoxy resin board coated with on double plane of copper with a thickness that is 1/30 and 1/50 of the resonant wavelength at a resonant frequency of 30.51 GHz and 48.15 GHz. The full width at half maximum (FWHM) reached 2.2 GHz and 2.35 GHz and the peak of the absorptance reached 99.977%. The ultrathin absorber is nearly omnidirectional for all polarizations. The test results of prepared sample testify the designed absorber's excellent absorbing performance forcefully. The absorber expands inspirations of radar stealth in military domain due to its flexible design, cost-effective and other outstanding properties.

  16. 21 CFR 872.6050 - Saliva absorber.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Saliva absorber. 872.6050 Section 872.6050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6050 Saliva absorber. (a) Identification. A saliva...

  17. Tuned mass absorber on a flexible structure

    DEFF Research Database (Denmark)

    Krenk, Steen; Høgsberg, Jan Becker

    2014-01-01

    The classic design of a tuned mass absorber is based on a simple two-mass analogy in which the tuned mass is connected to the structural mass with a spring and a viscous damper. In a flexible multi-degree-of-freedom structure the tuned mass absorber is typically introduced to provide damping of a...

  18. Simulation on Vapor Flow in the Absorber/Evaporator of an Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Nagamoto, Wataru; Sugiyama, Takahide

    Two-dimensional numerical computation methodology for vapor flow in the absorber/ evaporator in an absorption chiller has been suggested and the effect of pitch ratio of cylinders in the absorber/evaporator has been discussed. Pseudo-diffusion effects of surfactants added to lithium bromide solution flowing along cylinders in the absorber were considered into liquid film model suggested in the previous study. From the results, the present model was found to agree well with experimental data in a rather wide range of the pressure in the present system. The present model effectively reduces the computational load for vapor flow in the absorber/evaporator including 176 cylinders. Near the top and bottom walls of the absorber/evaporator, the high velocity regions were observed and the recirculating regions were also found to be formed just inside of the high velocity regions. This high velocity region is intensified with pitch-to-diameter ratio decrease because the vapor flow penetrating from the back side of the absorber increases for the pressure drop increase of front side of the absorber.

  19. [Absorbed doses in dental radiology].

    Science.gov (United States)

    Bianchi, S D; Roccuzzo, M; Albrito, F; Ragona, R; Anglesio, S

    1996-01-01

    The growing use of dento-maxillo-facial radiographic examinations has been accompanied by the publication of a large number of studies on dosimetry. A thorough review of the literature is presented in this article. Most studies were carried out on tissue equivalent skull phantoms, while only a few were in vivo. The aim of the present study was to evaluate in vivo absorbed doses during Orthopantomography (OPT). Full Mouth Periapical Examination (FMPE) and Intraoral Tube Panoramic Radiography (ITPR). Measurements were made on 30 patients, reproducing clinical conditions, in 46 anatomical sites, with 24 intra- and 22 extra-oral thermoluminiscent dosimeters (TLDS). The highest doses were measured, in orthopantomography, at the right mandibular angle (1899 mu Gy) in FMPE on the right naso-labial fold (5640 mu Gy and in ITPR on the palatal surface of the left second upper molar (1936 mu Gy). Intraoral doses ranged from 21 mu Gy, in orthopantomography, to 4494 mu Gy in FMPE. Standard errors ranged from 142% in ITPR to 5% in orthopantomography. The highest rate of standard errors was found in FMPE and ITPR. The data collected in this trial are in agreement with others in major literature reports. Disagreements are probably due to different exam acquisition and data collections. Such differences, presented comparison in several sites, justify lower doses in FMPE and ITPR. Advantages and disadvantages of in vivo dosimetry of the maxillary region are discussed, the former being a close resemblance to clinical conditions of examination and the latter the impossibility of collecting values in depth of tissues. Finally, both ITPR and FMPE required lower doses than expected, and can be therefore reconsidered relative to their radiation risk.

  20. Aircraft measurements of bromine monoxide, iodine monoxide, and glyoxal profiles in the tropics: comparison with ship-based and in situ measurements

    Science.gov (United States)

    Volkamer, R.; Baidar, S.; Campos, T. L.; Coburn, S.; DiGangi, J. P.; Dix, B.; Koenig, T. K.; Ortega, I.; Pierce, B. R.; Reeves, M.; Sinreich, R.; Wang, S.; Zondlo, M. A.; Romashkin, P. A.

    2015-01-01

    Tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO), iodine monoxide (IO), and small oxygenated hydrocarbons like glyoxal (CHOCHO) in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO2), water vapor (H2O) and O2-O2 collision complexes (O4) were measured by the CU Airborne Multi AXis Differential Optical Absorption Spectroscopy (CU AMAX-DOAS) instrument, in situ aerosol size distributions by an Ultra High Sensitivity Aerosol Spectrometer (UHSAS), and in situ H2O by Vertical-Cavity Surface-Emitting Laser hygrometer (VCSEL). Data are presented from two research flights (RF12, RF17) aboard the NSF/NCAR GV aircraft over the tropical Eastern Pacific Ocean (tEPO) as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO) project. We assess the accuracy of O4 slant column density (SCD) measurements in the presence and absence of aerosols, and find O4-inferred aerosol extinction profiles at 477 nm agree within 5% with Mie calculations of extinction profiles constrained by UHSAS. CU AMAX-DOAS provides a flexible choice of geometry which we exploit to minimize the SCD in the reference spectrum (SCDREF, maximize signal-to-noise), and to test the robustness of BrO, IO, and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01), and provides independent validation data from ship-based in situ Cavity Enhanced- and MAX-DOAS. Inside the marine boundary layer (MBL) no BrO was detected (smaller than 0.5 pptv), and 0.2-0.55 pptv IO and 32-36 pptv glyoxal were observed. The near surface concentrations agree within 20% (IO) and 10% (glyoxal) between ship and aircraft. The BrO concentration strongly

  1. Aircraft measurements of bromine monoxide, iodine monoxide, and glyoxal profiles in the tropics: comparison with ship-based and in situ measurements

    Directory of Open Access Journals (Sweden)

    R. Volkamer

    2015-01-01

    Full Text Available Tropospheric chemistry of halogens and organic carbon over tropical oceans modifies ozone and atmospheric aerosols, yet atmospheric models remain largely untested for lack of vertically resolved measurements of bromine monoxide (BrO, iodine monoxide (IO, and small oxygenated hydrocarbons like glyoxal (CHOCHO in the tropical troposphere. BrO, IO, glyoxal, nitrogen dioxide (NO2, water vapor (H2O and O2-O2 collision complexes (O4 were measured by the CU Airborne Multi AXis Differential Optical Absorption Spectroscopy (CU AMAX-DOAS instrument, in situ aerosol size distributions by an Ultra High Sensitivity Aerosol Spectrometer (UHSAS, and in situ H2O by Vertical-Cavity Surface-Emitting Laser hygrometer (VCSEL. Data are presented from two research flights (RF12, RF17 aboard the NSF/NCAR GV aircraft over the tropical Eastern Pacific Ocean (tEPO as part of the "Tropical Ocean tRoposphere Exchange of Reactive halogens and Oxygenated hydrocarbons" (TORERO project. We assess the accuracy of O4 slant column density (SCD measurements in the presence and absence of aerosols, and find O4-inferred aerosol extinction profiles at 477 nm agree within 5% with Mie calculations of extinction profiles constrained by UHSAS. CU AMAX-DOAS provides a flexible choice of geometry which we exploit to minimize the SCD in the reference spectrum (SCDREF, maximize signal-to-noise, and to test the robustness of BrO, IO, and glyoxal differential SCDs. The RF12 case study was conducted in pristine marine and free tropospheric air. The RF17 case study was conducted above the NOAA RV Ka'imimoana (TORERO cruise, KA-12-01, and provides independent validation data from ship-based in situ Cavity Enhanced- and MAX-DOAS. Inside the marine boundary layer (MBL no BrO was detected (smaller than 0.5 pptv, and 0.2–0.55 pptv IO and 32–36 pptv glyoxal were observed. The near surface concentrations agree within 20% (IO and 10% (glyoxal between ship and aircraft. The BrO concentration strongly

  2. Diamino protic ionic liquids for CO2 capture.

    Science.gov (United States)

    Vijayraghavan, R; Pas, Steven J; Izgorodina, Ekaterina I; MacFarlane, Douglas R

    2013-12-14

    A series of multifunctional protic ionic liquids (PILs), some of which are based on a combination of primary and tertiary amines in the same moiety coupled with a carboxylic acid, have been synthesised and employed for CO2 capture, yielding absorption capacities comparable to standard absorbents. In contrast to traditional amine absorbers, CO2 was found to desorb at lower temperatures and hence could result in a significant reduction in both the energy required to strip the absorber of CO2 and the thermally activated degradation mechanisms, which in traditional absorbers result in the loss of absorber and the production of toxic compounds. The lower basicity of the amine sites resultant from PIL formation decreases the binding energy of the CO2 to the absorber. The weaker basicity is also evidenced by lower pH of the PIL CO2 absorbers, which reduces common corrosion problems associated with traditional amine absorbers.

  3. Formation of orthorhombic tin dioxide from mechanically milled monoxide powders

    Science.gov (United States)

    Lamelas, F. J.

    2004-12-01

    X-ray scattering measurements are used to show that the metastable orthorhombic phase of tin dioxide is produced by the oxidation of mechanically milled litharge-phase tin monoxide. After milling to a grain size of approximately 20nm, followed by heating to 575°C, the fraction of the orthorhombic phase is approximately 80%. The orthorhombic phase was originally observed in high-pressure experiments, but more recently, it has been produced in a wide variety of thin-film and nanoparticle samples. The data presented here demonstrate the importance of small-grain-size tin monoxide as a precursor in the ambient-pressure synthesis of the orthorhombic phase. This result has practical importance in the production of tin dioxide gas sensors. A more fundamental observation is that the particle size of a precursor phase can have a marked effect on subsequent phases produced during oxidation. Lastly, a formula for determining the orthorhombic fraction in two-phase tin dioxide samples is developed using the method of standard additions.

  4. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  5. Space-based observation of volcanic iodine monoxide

    Science.gov (United States)

    Schönhardt, Anja; Richter, Andreas; Theys, Nicolas; Burrows, John P.

    2017-04-01

    Volcanic eruptions inject substantial amounts of halogens into the atmosphere. Chlorine and bromine oxides have frequently been observed in volcanic plumes from different instrumental platforms such as from ground, aircraft and satellites. The present study is the first observational evidence that iodine oxides are also emitted into the atmosphere during volcanic eruptions. Large column amounts of iodine monoxide, IO, are observed in satellite measurements following the major eruption of the Kasatochi volcano, Alaska, in 2008. The IO signal is detected in measurements made both by SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric CHartographY) on ENVISAT (Environmental Satellite) and GOME-2 (Global Ozone Monitoring Experiment-2) on MetOp-A (Meteorological Operational Satellite A). Following the eruption on 7 August 2008, strongly elevated levels of IO slant columns of more than 4 × 1013 molec cm-2 are retrieved along the volcanic plume trajectories for several days. The retrieved IO columns from the different instruments are consistent, and the spatial distribution of the IO plume is similar to that of bromine monoxide, BrO. Details in the spatial distribution, however, differ between IO, BrO and sulfur dioxide, SO2. The column amounts of IO are approximately 1 order of magnitude smaller than those of BrO. Using the GOME-2A observations, the total mass of IO in the volcanic plume injected into the atmosphere from the eruption of Kasatochi on 7 August 2008, is determined to be on the order of 10 Mg.

  6. The electric dipole moment of cobalt monoxide, CoO.

    Science.gov (United States)

    Zhuang, Xiujuan; Steimle, Timothy C

    2014-03-28

    A number of low-rotational lines of the E(4)Δ7/2 ← X(4)Δ7/2 (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h7/2, and the electron quadrupole parameter, eQq0, for the E(4)Δ7/2(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ(→)(el), for the X(4)Δ7/2 (υ = 0) and E(4)Δ7/2 (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F' = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F' = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  7. Carbon Monoxide Emissions in Middle Aged Debris Disks

    Science.gov (United States)

    Henderson, Morgan; Gorti, Uma; Hales, Antonio; Carpenter, John M.; Hughes, A. Meredith

    2017-01-01

    Circumstellar disks greater than 10 Myr old, referred to as debris disks, are expected to be gas poor. The original gas and dust in these disks is thought to be accreted onto the host stars, used up in the formation of planets and other bodies, or blown out of the disks via stellar radiation. However, recent ALMA observations at millimeter wavelengths have led to the detection of carbon monoxide (J=2-1) emission in a few debris disks, prompting further investigation.Using ALMA data, two separate models of gas genesis were tested against observations of the CO emissions in the disks around HIP 73145, HIP 76310, and HIP 84881 in the Upper Sco association. One of these models was built on the hypothesis that the gas in these debris disks is left over from stellar formation and has persisted over uncommonly long periods of time. The other model is built on the hypothesis that this gas is of secondary nature, produced by collisions between planetary bodies in the debris disks. Model emissions were calculated using the Line Modeling Engine (LIME) radiative transfer code and were compared with observational data to infer gas masses under both production scenarios. The implications of the masses of carbon monoxide in the disks suggested by each of the two models are discussed.

  8. Design of a nonlinear torsional vibration absorber

    Science.gov (United States)

    Tahir, Ammaar Bin

    Tuned mass dampers (TMD) utilizing linear spring mechanisms to mitigate destructive vibrations are commonly used in practice. A TMD is usually tuned for a specific resonant frequency or an operating frequency of a system. Recently, nonlinear vibration absorbers attracted attention of researchers due to some potential advantages they possess over the TMDs. The nonlinear vibration absorber, or the nonlinear energy sink (NES), has an advantage of being effective over a broad range of excitation frequencies, which makes it more suitable for systems with several resonant frequencies, or for a system with varying excitation frequency. Vibration dissipation mechanism in an NES is passive and ensures that there is no energy backflow to the primary system. In this study, an experimental setup of a rotational system has been designed for validation of the concept of nonlinear torsional vibration absorber with geometrically induced cubic stiffness nonlinearity. Dimensions of the primary system have been optimized so as to get the first natural frequency of the system to be fairly low. This was done in order to excite the dynamic system for torsional vibration response by the available motor. Experiments have been performed to obtain the modal parameters of the system. Based on the obtained modal parameters, the design optimization of the nonlinear torsional vibration absorber was carried out using an equivalent 2-DOF modal model. The optimality criterion was chosen to be maximization of energy dissipation in the nonlinear absorber attached to the equivalent 2-DOF system. The optimized design parameters of the nonlinear absorber were tested on the original 5-DOF system numerically. A comparison was made between the performance of linear and nonlinear absorbers using the numerical models. The comparison showed the superiority of the nonlinear absorber over its linear counterpart for the given set of primary system parameters as the vibration energy dissipation in the former is

  9. 40 CFR 52.1627 - Control strategy and regulations: Carbon monoxide.

    Science.gov (United States)

    2010-07-01

    ...: Carbon monoxide. 52.1627 Section 52.1627 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New Mexico § 52.1627 Control strategy and regulations: Carbon monoxide. (a) Part D Approval. The...

  10. Method of removing nitrogen monoxide from a nitrogen monoxide-containing gas using a water-soluble iron ion-dithiocarbamate, xanthate or thioxanthate

    Science.gov (United States)

    Liu, D. Kwok-Keung; Chang, Shih-Ger

    1987-08-25

    The present invention relates to a method of removing of nitrogen monoxide from a nitrogen monoxide-containing gas which method comprises contacting a nitrogen oxide-containing gas with an aqueous solution of water soluble organic compound-iron ion chelate complex. The NO absorption efficiency of ferrous urea-dithiocarbamate and ferrous diethanolamine-xanthate as a function of time, oxygen content and solution ph is presented. 3 figs., 1 tab.

  11. The Experimental Performance of an Unglazed PVT Collector with Two Different Absorber Types

    Directory of Open Access Journals (Sweden)

    Jin-Hee Kim

    2012-01-01

    Full Text Available Photovoltaic-thermal collectors combine photovoltaic modules and solar thermal collectors, forming a single device that produces electricity and heat simultaneously. There are two types of liquid-type PVT collectors, depending on the existence or absence of a glass cover over the PV module. The glass-covered (glazed PVT collector produces relatively more thermal energy but has a lower electrical yield, whereas the uncovered (unglazed PVT collector has a relatively low thermal energy and somewhat higher electrical performance. The thermal and electrical performance of liquid-type PVT collectors is related not only to the collector design, such as whether a glass cover is used, but also to the absorber design, that is, whether the absorber is for the sheet-and-tube type or the fully wetted type. The design of the absorber, as it comes into contact with the PV modules and the liquid tubes, is regarded as important, as it is related to the heat transfer from the PV modules to the liquid in the tubes. In this paper, the experimental performance of two liquid-type PVT collectors, a sheet-and-tube type and a fully wetted type, was analyzed.

  12. Practical absorption limits of MPP absorber

    Institute of Scientific and Technical Information of China (English)

    MAA Dah-You

    2006-01-01

    The construction and properties of microperforated panel (MPP) absorber are discussed. The absorption limit of the absorber had been shown that low values of the perforate constant k = d(f/10)1/2 and the orifice diameter d (in mm) are essential for MPP to have high absorption in wide frequency band. To find the exact limits, take 1 for k as a start, because both specific resistance and high absorption require k around one. And the orifice diameter d is chosen as 0.1 mm, so that the peak absorption coefficient (resonance absorption) is at 1000 Hz,and high sound frequency may be in the absorption region. Is it possible for a single layer of such an MPP to cover the whole absorption region required in practice? The half-absorption limit is not a good criterion, because low absorption comes in also in some cases. The 0.5 absorption coefficient limit is suggested for practical region, as a standard for comparison. Absorption curves were drawn for different load resistances, of absorption coefficients versus frequency.Ordinary MPP absorber absorbs in slightly over two octaves, and the new absorber with r = 1 (specific resistance equal to the characteristic impedance in air)is slightly better than these, 2.5 octaves. The new absorbers with r > 1, are much better than these, and some satisfies high absorption in broad frequency range. Realization of these will mean great progress of MPP absorbers.

  13. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    Science.gov (United States)

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p elderly people, environmental factors influence levels of exhaled carbon monoxide, carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  14. Absorbed dose by a CMOS in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Valero L, C. Y.; Guzman G, K. A.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L. C., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-10-15

    Absorbed dose by a complementary metal oxide semiconductor (CMOS) circuit as part of a pacemaker, has been estimated using Monte Carlo calculations. For a cancer patient who is a pacemaker carrier, scattered radiation could damage pacemaker CMOS circuits affecting patient's health. Absorbed dose in CMOS circuit due to scattered photons is too small and therefore is not the cause of failures in pacemakers, but neutron calculations shown an absorbed dose that could cause damage in CMOS due to neutron-hydrogen interactions. (Author)

  15. Graphene and Graphene Metamaterials for Terahertz Absorbers

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Pizzocchero, Filippo; Booth, Tim

    2013-01-01

    Graphene, due to the possibility to tune its conductivity, is the promising material for a range of the terahertz (THz) applications, such as tunable reflectors, absorbers, modulators, filters and polarization converters. Subwavelength structuring of graphene in order to form metamaterials allows...... for even more control over the THz waves. In this poster presentation I will show an elegant way to describe the graphene metamaterials and the design of graphene based absorbers. I will also present our recent experimental results on the graphene absorbers characterization....

  16. The nonlinear piezoelectric tuned vibration absorber

    Science.gov (United States)

    Soltani, P.; Kerschen, G.

    2015-07-01

    This paper proposes a piezoelectric vibration absorber, termed the nonlinear piezoelectric tuned vibration absorber (NPTVA), for the mitigation of nonlinear resonances of mechanical systems. The new feature of the NPTVA is that its nonlinear restoring force is designed according to a principle of similarity, i.e., the NPTVA should be an electrical analog of the nonlinear host system. Analytical formulas for the NPTVA parameters are derived using the homotopy perturbation method. Doing so, a nonlinear generalization of Den Hartog’s equal-peak tuning rule is developed for piezoelectric vibration absorbers.

  17. Design and application of functional absorbers

    Institute of Scientific and Technical Information of China (English)

    WANG Jiqing

    2004-01-01

    This paper gives an overview of the research at Institute of Acoustics, Tongji University, on functional absorbers and experience acquired in practical applications over the past three decades. Experiments and analysis of the absorption characteristics of three different geometrical forms of functional absorbers, i.e., panels, cubes and tubes, were conducted with different arrangements. The resulting esthetical effects are illustrated with pictures. Several non-fiber materials are used to compose functional absorbers with advantages both in acoustic properties and in architectural features. Cost effectiveness analysis is also given in order to provide design guidelines.

  18. Absorbed Energy in Ship Collisions and Grounding

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup; Zhang, Shengming

    1998-01-01

    is that the absorbed energy does not depend on the arrangement of the structure, the material properties, and the damage mode.The purpose of the present paper is to establish a new simple relation between the absorbed energy and the destroyed material volume, which can be used as a design tool for analysis of ship......Minorsky's well-known empirical formula, which relates the absorbed energy to the destroyed material volume, has been widely used in analyses of high energy collision and grounding accidents for nearly 40 years. The advantage of the method is its apparent simplcity. Obviously, its drawback...

  19. Absorbed dose by a CMOS in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Valero L, C. Y.; Guzman G, K. A.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L. C., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-10-15

    Absorbed dose by a complementary metal oxide semiconductor (CMOS) circuit as part of a pacemaker, has been estimated using Monte Carlo calculations. For a cancer patient who is a pacemaker carrier, scattered radiation could damage pacemaker CMOS circuits affecting patient's health. Absorbed dose in CMOS circuit due to scattered photons is too small and therefore is not the cause of failures in pacemakers, but neutron calculations shown an absorbed dose that could cause damage in CMOS due to neutron-hydrogen interactions. (Author)

  20. OPTIMIZATION OF COMPOUND AMINES-WATER ABSORBENTS OF UNIT EXTRACTION СО2 FROM SMOKE GASES

    OpenAIRE

    Лавренченко, Г. К.; Копытин, А. В.; Пятничко, А. И.; ИВАНОВ Ю.В.

    2014-01-01

    In installations for the production of low-temperature liquid carbon dioxide of low and average productivity using gaseous CO2 extracted from the combustion of natural gas. Extraction CO2 is carried in the unit absorption-desorption, consuming large quantities of heat. Consumption of heat in a unit depends on the properties of the absorbent. Most of the units of absorption/desorption is used as an absorbent water solution of monoethanolamine (MEA). Except the MEA also discussed other absorben...

  1. Space Compatible Radar Absorbing Materials Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase 1 project shall investigate novel radar absorbing materials (RAM) for use in space or simulated space environments. These materials are lightweight...

  2. An ultra-broadband multilayered graphene absorber

    KAUST Repository

    Amin, Muhammad

    2013-01-01

    An ultra-broadband multilayered graphene absorber operating at terahertz (THz) frequencies is proposed. The absorber design makes use of three mechanisms: (i) The graphene layers are asymmetrically patterned to support higher order surface plasmon modes that destructively interfere with the dipolar mode and generate electromagnetically induced absorption. (ii) The patterned graphene layers biased at different gate voltages backedup with dielectric substrates are stacked on top of each other. The resulting absorber is polarization dependent but has an ultra-broadband of operation. (iii) Graphene\\'s damping factor is increased by lowering its electron mobility to 1000cm 2=Vs. Indeed, numerical experiments demonstrate that with only three layers, bandwidth of 90% absorption can be extended upto 7THz, which is drastically larger than only few THz of bandwidth that can be achieved with existing metallic/graphene absorbers. © 2013 Optical Society of America.

  3. Semiconductor saturable absorbers for ultrafast THz signals

    DEFF Research Database (Denmark)

    Hoffmann, Matthias C.; Turchinovich, Dmitry

    We demonstrate saturable absorber behavior of n-type semiconductors in the THz frequency range using nonlinear THz spectroscopy. Further, we observe THz pulse shortening and increase of the group refractive index at high field strengths....

  4. Taming electromagnetic metamaterials for isotropic perfect absorbers

    Directory of Open Access Journals (Sweden)

    Doan Tung Anh

    2015-07-01

    Full Text Available Conventional metamaterial absorbers, which consist of a dielectric spacer sandwiched between metamaterial resonators and a metallic ground plane, have been inherently anisotropic. In this paper, we present an alternative approach for isotropic perfect absorbers using symmetric metamaterial structures. We show that by systematically manipulating the electrically and magnetically induced losses, one can achieve a desired absorption without breaking the structural homogeneity. Finite integration simulations and standard retrieval method are performed to elaborate on our idea.

  5. Absorbing Boundary Conditions for Hyperbolic Systems

    Institute of Scientific and Technical Information of China (English)

    Matthias Ehrhardt

    2010-01-01

    This paper deals with absorbing boundary conditions for hyperbolic systems in one and two space dimensions. We prove the strict well-posedness of the resulting initial boundary value problem in 1D. Afterwards we establish the GKS-stability of the corresponding Lax-Wendroff-type finite difference scheme. Hereby, we have to extend the classical proofs, since the (discretized) absorbing boundary conditions do not fit the standard form of boundary conditions for hyperbolic systems.

  6. Graphene and Graphene Metamaterials for Terahertz Absorbers

    OpenAIRE

    Andryieuski, Andrei; Pizzocchero, Filippo; Booth, Tim; Bøggild, Peter

    2013-01-01

    Graphene, due to the possibility to tune its conductivity, is the promising material for a range of the terahertz (THz) applications, such as tunable reflectors, absorbers, modulators, filters and polarization converters. Subwavelength structuring of graphene in order to form metamaterials allows for even more control over the THz waves. In this poster presentation I will show an elegant way to describe the graphene metamaterials and the design of graphene based absorbers. I will also present...

  7. Perfect terahertz absorber using fishnet based metafilm

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Abul Kalam [Los Alamos National Laboratory; Shchegolkov, Dmitry Yu [Los Alamos National Laboratory; Chen, Houtong [Los Alamos National Laboratory; Taylor, Antoinette [Los Alamos National Laboratory; Smirnova, E I [Los Alamos National Laboratory; O' Hara, John F [Los Alamos National Laboratory

    2009-01-01

    We present a perfect terahertz (THz) absorber working for a broad-angle of incidence. The two fold symmetry of rectangular fishnet structure allows either complete absorption or mirror like reflection depending on the polarization of incident the THz beam. Metamaterials enable the ability to control the electromagnetic wave in a unique fashion by designing the permittivity or permeability of composite materials with desired values. Although the initial idea of metamaterials was to obtain a negative index medium, however, the evolution of metamaterials (MMs) offers a variety of practically applicable devices for controlling electromagnetic wave such as tunable filters, modulators, phase shifters, compact antenna, absorbers, etc. Terahertz regime, a crucial domain of the electromagnetic wave, is suffering from the scarcity of the efficient devices and might take the advantage of metamaterials. Here, we demonstrate design, fabrication, and characterization of a terahertz absorber based on a simple fishnet metallic film separated from a ground mirror plane by a dielectric spacer. Such absorbers are in particular important for bolometric terahertz detectors, high sensitivity imaging, and terahertz anechoic chambers. Recently, split-ring-resonators (SRR) have been employed for metamaterial-based absorbers at microwave and THz frequencies. The experimental demonstration reveals that such absorbers have absorptivity close to unity at resonance frequencies. However, the downside of these designs is that they all employ resonators of rather complicated shape with many fine parts and so they are not easy to fabricate and are sensitive to distortions.

  8. Advances in micro-perforated panel absorbers

    Institute of Scientific and Technical Information of China (English)

    LIU Ke; TIAN Jing; JIAO Fenglei; L(U) Yadong

    2006-01-01

    Theoretical and experimental investigations on the performance of micro-perforated-panel absorbers are reviewed in this paper. By reviewing recent research work, this paper reveals a relationship between the maximum absorption coefficient and the limit of the absorption frequency bandwidth. It has been demonstrated that the absorption frequency bandwidth can be extended up to 3 or 4 octaves as the diameters of the micro-holes decrease. This has become possible with the development of the technologies for manufacturing micro-perforated panels,such as laser drilling, powder metallurgy, welded meshing and electro-etching to form micrometer order holes. In this paper, absorption characteristics of such absorbers in random fields and in high sound intensity are discussed both theoretically and experimentally. A new absorbing structure based on micro-perforated-panel absorbers demonstrate experimentally high sound absorption capability. This review shows that the micro-perforated-panel absorber has potentials to be one of ideal absorbing materials in the 21st century.

  9. Adaptive Piezoelectric Absorber for Active Vibration Control

    Directory of Open Access Journals (Sweden)

    Sven Herold

    2016-02-01

    Full Text Available Passive vibration control solutions are often limited to working reliably at one design point. Especially applied to lightweight structures, which tend to have unwanted vibration, active vibration control approaches can outperform passive solutions. To generate dynamic forces in a narrow frequency band, passive single-degree-of-freedom oscillators are frequently used as vibration absorbers and neutralizers. In order to respond to changes in system properties and/or the frequency of excitation forces, in this work, adaptive vibration compensation by a tunable piezoelectric vibration absorber is investigated. A special design containing piezoelectric stack actuators is used to cover a large tuning range for the natural frequency of the adaptive vibration absorber, while also the utilization as an active dynamic inertial mass actuator for active control concepts is possible, which can help to implement a broadband vibration control system. An analytical model is set up to derive general design rules for the system. An absorber prototype is set up and validated experimentally for both use cases of an adaptive vibration absorber and inertial mass actuator. Finally, the adaptive vibration control system is installed and tested with a basic truss structure in the laboratory, using both the possibility to adjust the properties of the absorber and active control.

  10. Hypervalence in monoxides and dioxides of superalkali clusters

    Science.gov (United States)

    Cochran, Elizabeth; Meloni, Giovanni

    2014-05-01

    F2Li3, a superalkali cluster, is characterized as having a lower adiabatic ionization energy than its elemental alkali counterpart and, coupled with the presence of complex molecular orbitals, suggests promise for novel bonding possibilities. CBS-QB3 composite method was used to study three distinct cluster isomers, as well as their cationic (+1) and anionic (-1) species, to identify energetic trends and observe geometric changes. Oxides were then generated from these clusters, of which three distinct monoxides and nine dioxides were obtained upon structure optimization. Identical calculations were performed for the oxide species and their charged counterparts. Some of the most stable oxides produced appear to possess hypervalent lithium and oxygen atoms, forming unique structures with exceptional stability.

  11. Carbon monoxide expedites metabolic exhaustion to inhibit tumor growth.

    Science.gov (United States)

    Wegiel, Barbara; Gallo, David; Csizmadia, Eva; Harris, Clair; Belcher, John; Vercellotti, Gregory M; Penacho, Nuno; Seth, Pankaj; Sukhatme, Vikas; Ahmed, Asif; Pandolfi, Pier Paolo; Helczynski, Leszek; Bjartell, Anders; Persson, Jenny Liao; Otterbein, Leo E

    2013-12-01

    One classical feature of cancer cells is their metabolic acquisition of a highly glycolytic phenotype. Carbon monoxide (CO), one of the products of the cytoprotective molecule heme oxygenase-1 (HO-1) in cancer cells, has been implicated in carcinogenesis and therapeutic resistance. However, the functional contributions of CO and HO-1 to these processes are poorly defined. In human prostate cancers, we found that HO-1 was nuclear localized in malignant cells, with low enzymatic activity in moderately differentiated tumors correlating with relatively worse clinical outcomes. Exposure to CO sensitized prostate cancer cells but not normal cells to chemotherapy, with growth arrest and apoptosis induced in vivo in part through mitotic catastrophe. CO targeted mitochondria activity in cancer cells as evidenced by higher oxygen consumption, free radical generation, and mitochondrial collapse. Collectively, our findings indicated that CO transiently induces an anti-Warburg effect by rapidly fueling cancer cell bioenergetics, ultimately resulting in metabolic exhaustion.

  12. The effect of carbon monoxide on planetary haze formation

    Energy Technology Data Exchange (ETDEWEB)

    Hörst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  13. Prevention of carbon monoxide exposure in general and recreational aviation.

    Science.gov (United States)

    Zelnick, Sanford D; Lischak, Michael W; Young, David G; Massa, Thomas V

    2002-08-01

    Carbon monoxide exposure is an important public health issue that poses a significant, albeit uncommon risk in aviation. Exposure is most common in single engine piston-driven aircraft where air is passed over the exhaust manifold to serve as cabin heat. Effective primary prevention of this exposure is the regular inspection and maintenance of aircraft exhaust systems, as required by law. For situations at special risk should exposure occur, and where there is concern for the public safety, installation of active warning devices for CO intrusion into cockpits may improve secondary prevention. Modern studies should be performed of occupation-specific abilities to support the 50 ppm FAA CO exposure standard and 50-70 ppm FAA Technical Standard Order (TSO) for CO monitors alerting pilots to the possibility of exhaust gas intrusion into their cockpits.

  14. ROLE OF ENDOGENOUS CARBON MONOXIDE IN ENDOTOXIN SHOCK

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective. To study the role of endogenous carbon monoxide (CO) in endotoxin shock. Methods. The changes of CO levels and the effects of zinc protoporphyrin IX (ZnPP),an inhibitor of heme-oxygenase (HO), in endotoxin shock and the efficacy of hemin,an inducer of HO were investigated.Results. The plasma CO levels were found to be significantly increased during the course of endotoxin shock. Injection of ZnPP was shown to abrogate the endotoxin-induced hypotension and metabolic derangements markedly. Administration of hemin to healthy rabbits revealed the hypotension and metabolic derangements similar to the animals given endotoxin.Conclusion.CO is a newly found endogenously produced mediator which may play an important role in the pathogenesis of endotoxin shock.

  15. ROLE OF ENDOGENOUS CARBON MONOXIDE IN ENDOTOXIN SHOCK

    Institute of Scientific and Technical Information of China (English)

    史源; 李华强; 潘捷; 覃世文; 潘凤; 蒋东波; 沈际皋

    2000-01-01

    Objective. To study the role of endogenous carbon monoxide (CO) in endotoxin shock. Methods. The changes of CO levels and the effects of zinc protoporphyrin IX (ZnPP), an inhibitor of hemeoxygenase (HO), in endotoxin shock and the efficacy of heroin, an inducer of HO were investigated. Results. The plasma CO levels were found to be significantly increased during the comse of endotoxin shock. Injection of ZnPP was shown to abrogate the endotoxin-induced hypotension and metabolic derangements markedly. Administration of hemin to healthy rabbits revealed the hypotension and metabolic derangements similar to the animsls given endotoxin. Conclusion. CO is a newly found endogenously produced mediator which may play an important role in the pathogenesis of endotoxin shock.

  16. Technique for measuring carbon monoxide uptake in mice

    Energy Technology Data Exchange (ETDEWEB)

    Depledge, M.H.; Collis, C.H.; Chir, B.; Barrett, A.

    1981-04-01

    A new method has been developed for measuring carbon monoxide (CO) uptake in mice. Each animal was placed in a syringe and allowed to rebreathe a mixture of CO and helium (He) for 60 s. CO uptake was detemined from a comparison of CO and He concentrations before and after rebreathing. Weight specific CO uptake increased with body weight in CBA mice weighing between 20 to 35 gr. In larger mice, size dependence was less marked, although a slight fall in CO uptake was observed in older animals. Anaesthesia reduced ventilatory rate and CO uptake to a variable extent. The method is reproducible, non-invasive and does not require anaesthesia; consequently, it can be used to study serial changes in lung function. It is sensitive enough to detect lung damage in CBA mice following 16 Gy total body irradiation. Values of diffusing capacity obtained for mice using this method are consistent with published values.

  17. Terahertz Time Domain Gas-phase Spectroscopy of Carbon Monoxide

    Science.gov (United States)

    Kilcullen, Patrick; Hartley, I. D.; Jensen, E. T.; Reid, M.

    2015-04-01

    Free induction decay signals emitted from Carbon Monoxide (CO) excited by sub-picosecond pulses of Terahertz (THz) radiation are directly measured in the time domain and compared to model calculations using a linear dispersion model to good agreement. Best fitting techniques of the data using the model allow the self-pressure broadening of CO to be measured across a range of absolute pressures, and the rotational constant to be determined. We find B V = 5.770 ± 0.003 × 1010 Hz in agreement with previous measurements. A partial pressure limit of detection for CO of 7900 ppm is estimated at atmosphere through extrapolating the calculated commensurate echo peaks down to low pressures with respect to the RMS noise floor of our THz time domain spectroscopy (THz-TDS) apparatus, which implies a limit of detection in the range of 40 ppm for commercial THz-TDS systems.

  18. An Unusual Cause of Supraventricular Tachycardia: Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Suat Zengin

    2014-03-01

    Full Text Available      Carbon monoxide (CO is a toxic gas produced by the incomplete combustion of carbon-containing compounds. Exposure to high concentrations of CO can be letha and is the most common cause of death from poisoning worldwide. Cardiac manifestations after exposure to CO, including myocardial ischemia, heart failure, and arrhythmias, have been reported. A 28-year-old a patient was admitted to our emergency department with altered consciousness as a consequence of acute domestic exposure to CO from a stove. His carboxyhemoglobin level was 39%. The oxygen treatment was started promptly, and therapeutic red cell exchange was performed. An electrocardiogram revealed supraventricular tachycardia (SVT, and an echocardiographic examination demonstrated normal cardiac functions. To the best of our knowledge, this study is the second to report a case of SVT attack due to acute CO intoxication. This paper discusses the management of this complication in patients poisoned with CO.

  19. Use and evaluation of disposable absorbent products for managing fecal incontinence by community-living people.

    Science.gov (United States)

    Bliss, Donna Z; Lewis, Jaclyn; Hasselman, Keegan; Savik, Kay; Lowry, Ann; Whitebird, Robin

    2011-01-01

    The use of disposable absorbent products by community-dwelling people with fecal incontinence (FI) was described. A survey was administered to 189 community-living individuals with FI at the start of a clinical trial about the effects of dietary fiber on FI. Forty-five percent of respondents (86/189) used an absorbent product to manage FI. More women (88%, 76/86, P = .009) and persons aged 65 years and older (44%, 38/86, P = .001) wore an absorbent product. Participants who wore an absorbent product for FI had a higher (worse) FI severity score (median, 4.75; range, 1-27; P = .006). Sixty-three users wore pantiliners and they were the only ones who used more than 3 products per day. Feminine hygiene products were worn more than incontinence products. Half of users were satisfied with the product they used. Evaluations of product features differed by type of product; odor control had some of the lowest ratings. Community-living individuals with FI, especially women and older individuals, tend to wear absorbent products. Perceptions of FI severity, preference, leakage of liquid stool, and presence of urinary incontinence influence the product type and pattern of wear. Participants report that modification of several features of absorbent products might make them more suitable for FI and increase satisfaction.

  20. Distributions of 12 elements on 64 absorbers from simulated Hanford Neutralized Current Acid Waste (NCAW)

    Energy Technology Data Exchange (ETDEWEB)

    Svitra, Z.V.; Bowen, S.M. [Los Alamos National Lab., NM (United States); Marsh, S.F. [Sandia National Labs., Albuquerque, NM (United States)

    1994-12-01

    As part of the Hanford Tank Waste Remediation System program at Los Alamos, we evaluated 64 commercially available or experimental absorber materials for their ability to remove hazardous components from high-level waste. These absorbers included cation and anion exchange resins, inorganic exchangers, composite absorbers, and a series of liquid extractants sorbed on porous support-beads. We tested these absorbers with a solution that simulates Hanford neutralized current acid waste (NCAW) (pH 14.2). To this simulant solution we added the appropriate radionuclides and used gamma spectrometry to measure fission products (Cs, Sr, Tc, and Y) and matrix elements (Cr, Co, Fe, Mn, Ni, V, Zn, and Zr). For each of 768 element/absorber combinations, we measured distribution coefficients for dynamic contact periods of 30 min, 2 h, and 6 h to obtain information about sorption kinetics. On the basis of these 2304 measured distribution coefficients, we determined that many of the tested absorbers may be suitable for processing NCAW solutions.

  1. Distributions of 15 elements on 58 absorbers from simulated Hanford Double-Shell Slurry Feed (DSSF)

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, S.F. [Sandia National Labs., Albuquerque, NM (United States); Svitra, Z.V.; Bowen, S.M. [Los Alamos National Lab., NM (United States)

    1994-11-01

    As part of the Hanford Tank Waste Remediation System program at Los Alamos, we evaluated 58 commercially available or experimental absorber materials for their ability to remove hazardous components from high-level waste. These absorbers included cation and anion exchange resins, inorganic exchangers, composite absorbers, pillared layered materials, and a series of liquid extractants sorbed on porous support-beads. We tested these absorbers with a solution that simulates Hanford double-shell slurry feed (DSSF) (pH 14.0). To this simulant solution we added the appropriate radionuclides and used gamma spectrometry to measure fission products (Ce, Cs, Sr, Tc, and Y), actinides (U and Am), and matrix elements (Cr, Co, Fe, Mn, Ni, V, Zn, and Zr). For each of 870 element/absorber combinations, we measured distribution coefficients for dynamic contact periods of 30 min, 2 h, and 6 h to obtain information about sorption kinetics. On the basis of these 2610 measured distribution coefficients, we determined that many of the tested absorbers may be suitable for processing DSSF solutions.

  2. Evidence for horizontal gene transfer of anaerobic carbon monoxide dehydrogenases

    Directory of Open Access Journals (Sweden)

    Stephen eTechtmann

    2012-04-01

    Full Text Available Carbon monoxide (CO is commonly known as a toxic gas, yet it is used by both aerobic and anaerobic bacteria and many archaea. In this study, we determined the prevalence of anaerobic carbon monoxide dehydrogenases (anaerobic CODHs, or [Ni,Fe]-CODHs in currently available genomic sequence databases. More than 6% (185 genomes out of 2887 bacterial and archaeal genome sequences in the IMG database possess at least one gene encoding [Ni,Fe]-CODH, the key enzyme for anaerobic CO utilization. The phylogenetic study of this extended protein family revealed nine distinct clades of [Ni,Fe]-CODHs. These clades consisted of [Ni,Fe]-CODHs that, while apparently monophyletic within the clades, were encoded by microorganisms of disparate phylogeny, based on 16S rRNA sequences, and widely ranging physiology. Following this discovery, it was therefore of interest to examine the extent and possible routes of horizontal gene transfer (HGT affecting [Ni,Fe]-CODH genes and gene clusters that include [Ni,Fe]-CODHs.The genome sequence of the extreme thermophile Thermosinus carboxydivorans was used as a case study for HGT. The [Ni,Fe]-CODH operon of T. carboxydivorans differs from its whole genome in its G+C content by 8.2 mol%. Here, we apply statistical methods to establish acquisition by T. carboxydivorans of the gene cluster including [Ni,Fe]-CODH via HGT. Analysis of tetranucleotide frequency and codon usage with application of the Kullback-Leibler divergence metric showed that the [Ni,Fe]-CODH-1 operon of T. carboxidyvorans is quite dissimilar to the whole genome. Using the same metrics, the T. carboxydivorans [Ni,Fe]-CODH-1 operon is highly similar to the genome of the phylogenetically distant anaerobic carboxydotroph Carboxydothermus hydrogenoformans. These results allow to assume recent HTG of the gene cluster from a relative of C. hydrogenoformans to T. carboxydivorans or a more ancient transfer from a C. hydrogenoformans ancestor to a T. carboxydivorans

  3. Hg⁰ removal from flue gas by ionic liquid/H₂O₂.

    Science.gov (United States)

    Cheng, Guangwen; Bai, Bofeng; Zhang, Qiang; Cai, Ming

    2014-09-15

    1-Alkyl-3-methylimidazolium chloride ionic liquids ([Cnmim] Cl, n=4, 6, 8) were prepared. The ionic liquid was then mixed with hydrogen peroxide (H2O2) to form an absorbent. The Hg(0) removal performance of the absorbent was investigated in a gas/liquid scrubber using simulated flue gas. It was found that the ionic liquid/H2O2 mixture was an excellent absorbent and could be used to remove Hg(0) from flue gas. When the mass ratio of H2O2 to ionic liquid was 0.5, the absorbent showed high Hg(0) removal efficiency (up to 98%). The Hg(0) removal efficiency usually increased with the absorption temperature, while decreased with the increase of alkyl chain length in ionic liquid molecule. The Hg(0) removal mechanism involved with Hg(0) oxidation by H2O2 and Hg(2+) transfer from aqueous phase to ionic liquid phase.

  4. The Effect of the Hayward Corridor Improvement Project on Carbon Monoxide Emission

    Science.gov (United States)

    Muhlfelder, M.; Martinez, E.; Maestas, A.; Peek, A.

    2013-12-01

    In August of 2010, construction began on a stretch of road in Downtown Hayward to address a problem with traffic flow. Known as the Hayward Corridor, the project reshaped the flow of traffic, replacing the two way streets of Foothill, Mission, and A Street with a loop between them. This project began with the initiative of reducing congestion in this area and improving access to businesses for pedestrians. The project was expected to have little environmental impact in most common assessments of degree of effect, including particulate matter, ozone and carbon monoxide levels. This report will discuss the effect of the Hayward Corridor Improvement Project on carbon monoxide emission. Data available to the public in the project's Environmental Impact Report shows that carbon monoxide levels before construction began were at an acceptable level according to federal and state standards. Projections for future concentrations both with and without the project show a decrease in carbon monoxide levels due to technological improvements and the gradual replacement of older, less efficient vehicles. The Environmental Impact Report projected that there would be little difference in carbon monoxide levels whether the project took place or not, at an average of 1.67x102 fewer parts per million per 1 hour period of measurement emitted in the case of the project not taking place. While it is not possible to draw a conclusion on what the current carbon monoxide levels would be if the project had not taken place due to the changes in traffic flow and other surrounding roads as a result of the project, the data gathered in June of 2013 suggested that carbon monoxide levels are higher than the values projected in 2007. This report summarizes both the accuracy of these carbon monoxide level projections and the effect of construction on carbon monoxide levels in the Hayward Corridor and the surrounding area.

  5. Comparison of molecular models of carbon monoxide for calculation of vapor-liquid equilibrium

    Directory of Open Access Journals (Sweden)

    Bibian Alonso Hoyos-Madrigal

    2015-01-01

    Full Text Available Existen varios modelos moleculares para el monóxido de carbono desarrollados a partir de diferentes mediciones experimentales. El objetivo de este trabajo es comparar los resultados que varios de estos modelos producen en el cálculo del equilibrio líquido-vapor en busca de recomendar qué modelo debe ser usado de acuerdo la propiedad y la fase que se desea calcular. Los modelos seleccionados corresponden a cuatro modelos no polares, con uno o dos sitios Lennard-Jones, y cuatro modelos polares, con dipolos o cargas parciales para representar la polaridad del monóxido de carbono. Simulaciones Monte Carlo en la versión Gibbs canónica (NVT-GEMC se emplearon para determinar las densidades de las fases en equilibrio, la presión de vapor y la entalpia de vaporización entre 80 y 130 K con cada uno de los modelos seleccionados. Se encontró que los modelos más complejos SVH, ANC y PGB, son los que mejor describen la densidad del líquido saturado (alrededor de 7% de desviación promedio, pero estos modelos generan desviaciones mayores al 40% para las propiedades del vapor y al 20% para la entalpia de vaporización. Por otro lado, el modelo no- polar BLF generó las menores desviaciones para la presión de saturación y la densidad del vapor (6.8 y 21.5%, respectivamente. Este modelo, al igual que el modelo HCB, produce desviaciones aceptables para la densidad del líquido y la entalpia de vaporización (entre 10 y 12%. Los modelos no polares BLF y HCB, que no requieren el cálculo de las interacciones de largo alcance, se pueden considerar como los modelos moleculares que presentan un balance satisfactorio entre desviaciones en los resultados y complejidad de cálculo.

  6. Multifunctional Solar Systems Based On Two-Stage Regeneration Absorbent Solution

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2015-04-01

    Full Text Available The concepts of multifunctional dehumidification solar systems, heat supply, cooling, and air conditioning based on the open absorption cycle with direct absorbent regeneration developed. The solar systems based on preliminary drainage of current of air and subsequent evaporated cooling. The solar system using evaporative coolers both types (direct and indirect. The principle of two-stage regeneration of absorbent used in the solar systems, it used as the basis of liquid and gas-liquid solar collectors. The main principle solutions are designed for the new generation of gas-liquid solar collectors. Analysis of the heat losses in the gas-liquid solar collectors, due to the mechanism of convection and radiation is made. Optimal cost of gas and liquid, as well as the basic dimensions and configuration of the working channel of the solar collector identified. Heat and mass transfer devices, belonging to the evaporative cooling system based on the interaction between the film and the gas stream and the liquid therein. Multichannel structure of the polymeric materials used to create the tip. Evaporative coolers of water and air both types (direct and indirect are used in the cooling of the solar systems. Preliminary analysis of the possibilities of multifunctional solar absorption systems made reference to problems of cooling media and air conditioning on the basis of experimental data the authors. Designed solar systems feature low power consumption and environmental friendliness.

  7. Adsorption of nitrogen and carbon monoxide on clinoptilolite: determination and prediction of pure and binary isotherms

    Energy Technology Data Exchange (ETDEWEB)

    Triebe, R.W.; Tezel, F.H. [University of Ottawa, Ottawa, ON (Canada). Department of Chemical Engineering

    1995-10-01

    The adsorption of carbon monoxide and nitrogen on clinoptilolite is studied to determine the natural zeolite`s potential for air purification. Pure and binary isotherms were determined for nitrogen and carbon monoxide on a natural Turkish clinoptilolite under near ambient conditions. Experimentally determined isotherms are compared to predictions based on various models from the literature. The Wilson form of the Vacancy Solution Theory is the only model that provides reasonable agreement with the binary isotherm. Clinoptilolite is concluded to be a promising sorbent for separation of carbon monoxide and nitrogen. 30 refs., 11 figs., 5 tabs.

  8. Cyclodextrins: a new efficient absorbent to treat waste gas streams.

    Science.gov (United States)

    Blach, Philippe; Fourmentin, Sophie; Landy, David; Cazier, Fabrice; Surpateanu, Gheorghe

    2008-01-01

    Volatile Organic Compounds (VOCs) in the air provoke health and environmental concerns. This paper focuses on the absorption method to treat industrial polluted air loaded with VOCs. The key variable of this treatment being the choice of a suitable liquid absorbent, the aim of this research work is to investigate the effectiveness and the regeneration of a new potential family of absorbent: cyclodextrins (CDs). All CDs derivatives tested are able to decrease the Henry's law constant of toluene: a reduction of volatility up to 95% may be obtained, depending on CD nature and concentration. Moreover, absorption experiments show that beta-CD, which presents the highest absorption ability, is 250 time more efficient than water. The absorption efficiency is not totally correlated with static experiments, suggesting that, in addition to Henry's law constants and inclusion compounds stability, toluene diffusion into such solutions has to be taken into account. It is also to be noted that salt and pH variations seem to have little influence on the absorption capacity of CDs, which may be of great interest for industrial applications. Finally, since production of solid compounds was not observed during these experiments and since temperature decreases the capture ability in a drastic way, regeneration of the washing solution can be achieved by heating the solution in combination with air stripping.

  9. A transportable spectrometer for in situ and local measurements of iodine monoxide at mixing ratios in the 10-14 range

    Science.gov (United States)

    Méjean, Guillaume; Grilli, Roberto; Abd Alrahman, Chadi; Ventrillard, Irène; Kassi, Samir; Romanini, Daniele

    2012-06-01

    We present a robust, compact, and transportable instrument that measures the iodine monoxide atmospheric radical at extremely low concentration, down to 40 ppqv (parts per quadrillion by volume, 1:1015). As nitrogen dioxide is strongly absorbed in the same spectral region it could be simultaneously measured down to 4 pptv (parts per trillion by volume, 1:1012). Relying on "mode locked cavity-enhanced absorption spectroscopy," the instrument makes use of a free-running commercial femtosecond Titane Saphir laser. We demonstrate that this multiplex detection scheme provides shot noise limited spectra for acquisition times as long as 5 min. Moreover, this instrument is very versatile as it can be potentially tuned from the infrared to the ultraviolet (1080-340 nm) to reach various molecular absorptions. It has been recently deployed at the Station Biologique de Roscoff on the North West Atlantic coast of France.

  10. Warm Absorber Diagnostics of AGN Dynamics

    Science.gov (United States)

    Kallman, Timothy

    Warm absorbers and related phenomena are observable manifestations of outflows or winds from active galactic nuclei (AGN) that have great potential value. Understanding AGN outflows is important for explaining the mass budgets of the central accreting black hole, and also for understanding feedback and the apparent co-evolution of black holes and their host galaxies. In the X-ray band warm absorbers are observed as photoelectric absorption and resonance line scattering features in the 0.5-10 keV energy band; the UV band also shows resonance line absorption. Warm absorbers are common in low luminosity AGN and they have been extensively studied observationally. They may play an important role in AGN feedback, regulating the net accretion onto the black hole and providing mechanical energy to the surroundings. However, fundamental properties of the warm absorbers are not known: What is the mechanism which drives the outflow?; what is the gas density in the flow and the geometrical distribution of the outflow?; what is the explanation for the apparent relation between warm absorbers and the surprising quasi-relativistic 'ultrafast outflows' (UFOs)? We propose a focused set of model calculations that are aimed at synthesizing observable properties of warm absorber flows and associated quantities. These will be used to explore various scenarios for warm absorber dynamics in order to answer the questions in the previous paragraph. The guiding principle will be to examine as wide a range as possible of warm absorber driving mechanisms, geometry and other properties, but with as careful consideration as possible to physical consistency. We will build on our previous work, which was a systematic campaign for testing important class of scenarios for driving the outflows. We have developed a set of tools that are unique and well suited for dynamical calculations including radiation in this context. We also have state-of-the-art tools for generating synthetic spectra, which are

  11. Ultrathin flexible dual band terahertz absorber

    Science.gov (United States)

    Shan, Yan; Chen, Lin; Shi, Cheng; Cheng, Zhaoxiang; Zang, Xiaofei; Xu, Boqing; Zhu, Yiming

    2015-09-01

    We propose an ultrathin and flexible dual band absorber operated at terahertz frequencies based on metamaterial. The metamaterial structure consists of periodical split ring resonators with two asymmetric gaps and a metallic ground plane, separated by a thin-flexible dielectric spacer. Particularly, the dielectric spacer is a free-standing polyimide film with thickness of 25 μm, resulting in highly flexible for our absorber and making it promising for non-planar applications such as micro-bolometers and stealth aircraft. Experimental results show that the absorber has two resonant absorption frequencies (0.41 THz and 0.75 THz) with absorption rates 92.2% and 97.4%, respectively. The resonances at the absorption frequencies come from normal dipole resonance and high-order dipole resonance which is inaccessible in the symmetrical structure. Multiple reflection interference theory is used to analyze the mechanism of the absorber and the results are in good agreement with simulated and experimental results. Furthermore, the absorption properties are studied under various spacer thicknesses. This kind of metamaterial absorber is insensitive to polarization, has high absorption rates (over 90%) with wide incident angles range from 0° to 45° and the absorption rates are also above 90% when wrapping it to a curved surface.

  12. Oxygen absorbers in food preservation: a review.

    Science.gov (United States)

    Cichello, Simon Angelo

    2015-04-01

    The preservation of packaged food against oxidative degradation is essential to establish and improve food shelf life, customer acceptability, and increase food security. Oxygen absorbers have an important role in the removal of dissolved oxygen, preserving the colour, texture and aroma of different food products, and importantly inhibition of food spoilage microbes. Active packaging technology in food preservation has improved over decades mostly due to the sealing of foods in oxygen impermeable package material and the quality of oxygen absorber. Ferrous iron oxides are the most reliable and commonly used oxygen absorbers within the food industry. Oxygen absorbers have been transformed from sachets of dried iron-powder to simple self-adhesive patches to accommodate any custom size, capacity and application. Oxygen concentration can be effectively lowered to 100 ppm, with applications spanning a wide range of food products and beverages across the world (i.e. bread, meat, fish, fruit, and cheese). Newer molecules that preserve packaged food materials from all forms of degradation are being developed, however oxygen absorbers remain a staple product for the preservation of food and pharmaceutical products to reduce food wastage in developed nations and increased food security in the developing & third world.

  13. Detecting and interpreting statistical lensing by absorbers

    CERN Document Server

    Ménard, B

    2004-01-01

    We propose a method for detecting gravitational magnification of distant sources, like quasars, due to absorber systems detected in their spectra. We first motivate the use of metal absorption lines rather than Lyman-alpha lines, then we show how to relate the observed moments of the source magnitude distribution to the mass distribution of absorbers. In order to illustrate the feasibility of the method, we use a simple model to estimate the amplitude of the effect expected for MgII absorption lines, and show that their lensing signal might already be detectable in large surveys like the SDSS. Our model suggests that quasars behind strong MgII absorbers are in average brightened by -0.05 to -0.2 magnitude due to magnification. One must therefore revisit the claim that, in magnitude limited surveys, quasars with strong absorbers tend to be missed due to extinction effects. In addition to constraining the mass of absorber systems, applying our method will allow for the quantification of this bias.

  14. Distributed Absorber for Noise and Vibration Control

    Directory of Open Access Journals (Sweden)

    Michel Azoulay

    2011-01-01

    Full Text Available An approach to a wide-band frequency passive vibration attenuation is introduced in this paper. This aims to suppress noise and vibration of extended multimode objects like plates, panels and shells. The absorber is arranged in the form of a single-layer assembly of small inertial bodies (balls being distributed and moulded within the light visco-elastic media (e.g. silicone resin. The absorber as a whole is embedded into object face covering the critical patches of the system surface. For the purpose of characterization, the authors introduced the complex frequency response function relating the volume velocity produced by the vibrating object surface (response stimulated by a point-wise force (stimulus applied to a particular point. The simulation and optimization of the main frequency characteristics has been performed using a full scale 3-dimensional Finite Element model. These revealed some new dynamic features of absorber's structures, which can contribute to vibration attenuation. A full-scale physical experimentation with synthesised absorber's structures confirmed the main results of simulation and has shown significant noise reduction over a staggering 0–20 kHz frequency band. This was achieved with a negligible weight and volume penalty due to the addition of the absorber. The results can find multiple applications in noise and vibration control of different structures. Some examples of such applications are presented.

  15. A Naked Eye Refractive Index Sensor with a Visible Multiple Peak Metamaterial Absorber

    Directory of Open Access Journals (Sweden)

    Heli Ma

    2015-03-01

    Full Text Available We report a naked eye refractive index sensor with a visible metamaterial absorber. The visible metamaterial absorber consisting of a silver dendritic/dielectric/metal structure shows multiple absorption peaks. By incorporating a gain material (rhodamine B into the dielectric layer, the maximal magnitude of the absorption peak can be improved by about 30%. As the metamaterial absorber is sensitive to the refractive index of glucose solutions, it can function as a sensor that quickly responds to variations of the refractive index of the liquid. Meanwhile, since the response is presented via color changes, it can be clearly observed by the naked eyes. Further experiments have confirmed that the sensor can be used repeatedly.

  16. Absorbing material based on starch having improved absorbent properties and process for the preparation thereof

    NARCIS (Netherlands)

    Feil, H.; Soest, van J.J.G.; Schijndel, van R.J.G.

    1999-01-01

    A biodegradable, highly water-absorbing polymer based on starch or derivatives thereof is described, wherein the starch has not been chemically modified or only to a degree of substitution below 0.2, and has a water-absorbing power of at least 10 times its own weight, half of the water absorption be

  17. Non-Absorbable Gas Behavior in the Absorber/Evaporator of a Absorption Chiller

    Science.gov (United States)

    Suzuki, Hiroshi; Nagamoto, Wataru; Sugiyama, Takahide

    A two-dimensional numerical study on non-absorbable gas behavior in the absorber/evaporator of an absorption chiller has been performed. In the present study, the effect of the pitch-to-diameter ratio of a cylinder bundle in the absorber was highlighted. From the results, a sudden decrease of the overall heat transfer coefficient of the absorber was observed at a certain mean concentration of non-absorbable gas for each pitch-to-diameter ratio. Such a critical concentration was also found to decrease as the pitch-to- diameter ratio increased. The sudden decrease occurs due to the sudden disappearance of recirculating region, which is formed between the absorber and the evaporator, and where most of non-absorbable gas stays when it exists. As the pitch-to-diameter ratio increases, the recirculating region becomes weak because the velocity of the high velocity region supporting the recirculating flow decreases. Then, the critical mean concentration of non-absorbable gas is found to decrease as pitch-to-ratio increases.

  18. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  19. Distributed electric absorbers of beam vibrations

    Science.gov (United States)

    dell'lsola, Francesco; Del Vescovo, Dionisio; Maurini, Corrado

    2003-07-01

    Several electric vibration absorbers based on distributed piezoelectric control of beam vibrations are studied. The damping devices are conceived by interconnecting with different modular electric networks an array of piezoelectric transducers uniformly distributed on a beam. Five different vibration absorbers made of five different network interconnecting topologies are considered and their damping performances are analyzed and compared. The analysis is based on homogenized models of modular piezo-electromechanical systems. The optimal parameters of these absorbers are found by adopting the criterion of critical damping of waves with a single wave number. We show that: i) there is an interconnecting network providing an optimal multimodal damping; ii) the performances required to the electr(on)ic components can be significantly decreased by increasing the number (and decreasing the dimensions) of the piezoelectric transducers.

  20. On the warm absorber in AGN outflow

    CERN Document Server

    Adhikari, T P; Sobolewska, M; Czerny, B

    2016-01-01

    Warm absorber (WA) is an ionised gas present in the line of sight to the AGN central engine. The effect of the absorber is imprinted in the absorption lines observed in X-ray spectra of AGN. In this work, we model the WA in Seyfert 1 galaxy Mrk 509 using its recently published shape of broad band spectral energy distribution (SED) as a continuum illuminating the absorber. Using the photoionization code {\\sc Titan}, recently we have shown that the absorption measure distribution (AMD) found for this object can be successfully modelled as a single slab of gas in total pressure (radiation+gas) equilibrium, contrary to the usual models of constant density multiple slabs. We discuss the transmitted spectrum that would be recorded by an observer after the radiation from the nucleus passes through the WA.

  1. Ferrite HOM Absorber for the RHIC ERL

    Energy Technology Data Exchange (ETDEWEB)

    Hahn,H.; Choi, E.M.; Hammons, L.

    2008-10-01

    A superconducting Energy Recovery Linac is under construction at Brookhaven National Laboratory to serve as test bed for RHIC upgrades. The damping of higher-order modes in the superconducting five-cell cavity for the Energy-Recovery linac at RHIC is performed exclusively by two ferrite absorbers. The ferrite properties have been measured in ferrite-loaded pill box cavities resulting in the permeability values given by a first-order Debye model for the tiled absorber structure and an equivalent permeability value for computer simulations with solid ring dampers. Measured and simulated results for the higher-order modes in the prototype copper cavity are discussed. First room-temperature measurements of the finished niobium cavity are presented which confirm the effective damping of higher-order modes in the ERL. by the ferrite absorbers.

  2. Broadband plasmonic absorber for photonic integrated circuits

    CERN Document Server

    Xiong, Xiao; Ren, Xi-Feng; Guo, Guang-Can

    2013-01-01

    The loss of surface plasmon polaritons has long been considered as a fatal shortcoming in information transport. Here we propose a plasmonic absorber utilizing this "shortcoming" to absorb the stray light in photonic integrated circuits (PICs). Based on adiabatic mode evolution, its performance is insensitive to incident wavelength with bandwidth larger than 300nm, and robust against surrounding environment and temperature. Besides, the use of metal enables it to be very compact and beneficial to thermal dissipation. With this 40um-long absorber, the absorption efficiency can be over 99.8% at 1550nm, with both the reflectivity and transmittance of incident light reduced to less than 0.1%. Such device may find various applications in PICs, to eliminate the residual strong pump laser or stray light.

  3. Interference theory of metamaterial perfect absorbers

    CERN Document Server

    Chen, Hou-Tong

    2011-01-01

    The impedance matching in metamaterial perfect absorbers has been believed to involve and rely on magnetic resonant response, with a direct evidence from the anti-parallel directions of surface currents in the metal structures. Here we present a different theoretical interpretation based on interferences, which shows that the two layers of metal structure in metamaterial absorbers are linked only by multiple reflections with negligible near-field interactions or magnetic resonances. This is further supported by the out-of-phase surface currents derived at the interfaces of resonator array and ground plane through multiple reflections and superpositions. The theory developed here explains all features observed in narrowband metamaterial absorbers and therefore provides a profound understanding of the underlying physics.

  4. Absorber Materials at Room and Cryogenic Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    F. Marhauser, T.S. Elliott, A.T. Wu, E.P. Chojnacki, E. Savrun

    2011-09-01

    We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

  5. The Development and Application of Two-Chamber Reactors and Carbon Monoxide Precursors for Safe Carbonylation Reactions.

    Science.gov (United States)

    Friis, Stig D; Lindhardt, Anders T; Skrydstrup, Troels

    2016-04-19

    Low molecular weight gases (e.g., carbon monoxide, hydrogen, and ethylene) represent vital building blocks for the construction of a wide array of organic molecules. Whereas experimental organic chemists routinely handle solid and liquid reagents, the same is not the case for gaseous reagents. Synthetic transformations employing such reagents are commonly conducted under pressure in autoclaves or under atmospheric pressure with a balloon setup, which necessitates either specialized equipment or potentially hazardous and nonrecommended installations. Other safety concerns associated with gaseous reagents may include their toxicity and flammability and, with certain gases, their inability to be detected by human senses. Despite these significant drawbacks, industrial processes apply gaseous building blocks regularly due to their low cost and ready availability but nevertheless under a strictly controlled manner. Carbon monoxide (CO) fits with all the parameters for being a gas of immense industrial importance but with severe handling restrictions due to its inherent toxicity and flammability. In academia, as well as research and development laboratories, CO is often avoided because of these safety issues, which is a limitation for the development of new carbonylation reactions. With our desire to address the handling of CO in a laboratory setting, we designed and developed a two-chamber reactor (COware) for the controlled delivery and utilization of stoichiometric amounts of CO for Pd-catalyzed carbonylation reactions. In addition to COware, two stable and solid CO-releasing molecules (COgen and SilaCOgen) were developed, both of which release CO upon activation by either Pd catalysis or fluoride addition, respectively. The unique combination of COware with either COgen or SilaCOgen provides a simple reactor setup enabling synthetic chemists to easily perform safe carbonylation chemistry without the need for directly handling the gaseous reagent. With this technology

  6. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  7. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  8. Personal Exposure Monitoring of Particulate Matter, Nitrogen Dioxide, and Carbon Monoxide, including Susceptible Groups

    National Research Council Canada - National Science Library

    R. M. Harrison; C. A. Thornton; R. G. Lawrence; D. Mark; R. P. Kinnersley; J. G. Ayres

    2002-01-01

    Aims: To investigate the relation between personal exposures to nitrogen dioxide, carbon monoxide, and PM10, and exposures estimated from static concentrations of these pollutants measured within the same...

  9. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  10. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  11. The influence of tobacco blend composition on carbon monoxide formation in mainstream cigarette smoke

    National Research Council Canada - National Science Library

    Djulančić, Nermina; Radojičić, Vesna; Srbinovska, Marija

    2013-01-01

    ...) in the gas phase of mainstream cigarette smoke. The results showed that the type of tobacco examined had a significant impact on the amount of carbon monoxide production in the gas phase of cigarette smoke...

  12. Cobalt promoted copper manganese oxide catalysts for ambient temperature carbon monoxide oxidation.

    Science.gov (United States)

    Jones, Christopher; Taylor, Stuart H; Burrows, Andrew; Crudace, Mandy J; Kiely, Christopher J; Hutchings, Graham J

    2008-04-14

    Low levels of cobalt doping (1 wt%) of copper manganese oxide enhances its activity for carbon monoxide oxidation under ambient conditions and the doped catalyst can display higher activity than current commercial catalysts.

  13. Electronic structure and optical properties of a new type of semiconductor material:graphene monoxide

    Institute of Scientific and Technical Information of China (English)

    Yang Gui; Zhang Yufeng; Yan Xunwang

    2013-01-01

    The electronic and optical properties of graphene monoxide,a new type of semiconductor material,are theoretically studied by first-principles density functional theory.The calculated band structure shows that graphene monoxide is a semiconductor with a direct band gap of 0.95 eV.The density of states of graphene monoxide and the partial density of states for C and O are given to understand the electronic structure.In addition,we calculate the optical properties of graphene monoxide,including the complex dielectric function,absorption coefficient,complex refractive index,loss-function,reflectivity and conductivity.These results provide a physical basis for potential application in optoelectronic devices.

  14. Precise dispersion equations of absorbing filter glasses

    Science.gov (United States)

    Reichel, S.; Biertümpfel, Ralf

    2014-05-01

    The refractive indices versus wavelength of optical transparent glasses are measured at a few wavelengths only. In order to calculate the refractive index at any wavelength, a so-called Sellmeier series is used as an approximation of the wavelength dependent refractive index. Such a Sellmeier representation assumes an absorbing free (= loss less) material. In optical transparent glasses this assumption is valid since the absorption of such transparent glasses is very low. However, optical filter glasses have often a rather high absorbance in certain regions of the spectrum. The exact description of the wavelength dependent function of the refractive index is essential for an optimized design for sophisticated optical applications. Digital cameras use an IR cut filter to ensure good color rendition and image quality. In order to reduce ghost images by reflections and to be nearly angle independent absorbing filter glass is used, e.g. blue glass BG60 from SCHOTT. Nowadays digital cameras improve their performance and so the IR cut filter needs to be improved and thus the accurate knowledge of the refractive index (dispersion) of the used glasses must be known. But absorbing filter glass is not loss less as needed for a Sellmeier representation. In addition it is very difficult to measure it in the absorption region of the filter glass. We have focused a lot of effort on measuring the refractive index at specific wavelength for absorbing filter glass - even in the absorption region. It will be described how to do such a measurement. In addition we estimate the use of a Sellmeier representation for filter glasses. It turns out that in most cases a Sellmeier representation can be used even for absorbing filter glasses. Finally Sellmeier coefficients for the approximation of the refractive index will be given for different filter glasses.

  15. Spectral Absorbing Capacity of Brown Carbon Aerosols Over Indo-Gangetic Plain

    Science.gov (United States)

    Tripathi, S. N.; Moosakutty, S. P.; Satish, R. V.; Thamban, N. M.; Rastogi, N.

    2016-12-01

    Organic carbon dominates in atmospheric particulate matter concentration all over the world. A part of organic carbon is known to absorb light in ultra-violet and mid visible wavelengths. Such absorbing organics are collectively called brown carbon (BrC). We present spectral BrC imaginary refractive indices of water soluble organic carbon (WSOC) and total organic carbon (OC) during the winter-spring season of 2015-16. Measurements were made from the city of Kanpur, India located inside the Indo-Gangetic Plain (IGP). Winter-spring season in the IGP is known for its high aerosol loading due to frequent wood and trash burning. Absorption and mass concentration of WSOC is measured using a combination of Particles in to Liquid (PILS), Liquid Waveguide Capillary Cell (LWCC) and Total Organic Carbon (TOC) analyzer system. Same for OC is measured using an offline method, where samples were collected over quartz filter and then analyzed in LWCC and OC-EC analyzer. Our results show that BrC in the IGP is highly absorbing when compared to other parts of the world. The WSOC shows more absorbing capacity compared to OC. Spectral nature of the refractive indices shows WSOC with a higher wavelength dependence compared to OC. Above 470 nm wavelength absorption capacity of WSOC is negligible but absorbance from OC is visible till 565 nm. Incorporating these measured values, a modeling approach is derived to identify the percentage contribution of different absorbing species to total aerosol absorption. Our results show the special characteristics of organics in IGP.

  16. Durability of Polymeric Glazing and Absorber Materials

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, G.; Terwilliger, K.; Bingham, C.; Lindquist, C.; Milbourne, M.

    2005-11-01

    The Solar Heating and Lighting Program has set the goal of reducing the cost of solar water heating systems by at least 50%. An attractive approach to such large cost reduction is to replace glass and metal parts with less-expensive, lighter-weight, more-integrated polymeric components. The key challenge with polymers is to maintain performance and assure requisite durability for extended lifetimes. We have begun evaluation of several new UV-screened polycarbonate sheet glazing constructions. This has involved interactions with several major polymer industry companies to obtain improved candidate samples. Proposed absorber materials were tested for UV resistance, and appear adequate for unglazed ICS absorbers.

  17. Timing the warm absorber in NGC 4051

    Science.gov (United States)

    Silva, C. V.; Uttley, P.; Costantini, E.

    2016-12-01

    We investigated, using spectral-timing analysis, the characterization of highly ionized outflows in Seyfert galaxies, the so-called warm absorbers. Here, we present our results of the extensive 600 ks of XMM-Newton archival observations of the bright and highly variable Seyfert 1 galaxy NGC 4051 whose spectrum has revealed a complex multicomponent wind. Making use of both RGS and EPIC-pn data, we performed a detailed analysis through a time-dependent photoionization code in combination with spectral and Fourier spectral-timing techniques. The source light curves and the warm absorber parameters obtained from the data were used to simulate the response of the gas to variations in the ionizing flux of the central source. The resulting time variable spectra were employed to predict the effects of the warm absorber on the time lags and coherence of the energy dependent light curves. We have found that, in the absence of any other lag mechanisms, a warm absorber with the characteristics of the one observed in NGC 4051, is able to produce soft lags, up to 100 s, on timescales of hours. The time delay is associated with the response of the gas to changes in the ionizing source, either by photoionization or radiative recombination, which is dependent on its density. The range of radial distances that, under our assumptions, yield longer time delays are distances r 0.3-1.0 × 1016 cm, and hence gas densities n 0.4-3.0 × 107 cm-3. Since these ranges are comparable to the existing estimates of the location of the warm absorber in NGC 4051, we suggest that it is likely that the observed X-ray time lags may carry a signature of the warm absorber response time to changes in the ionizing continuum. Our results show that the warm absorber in NGC 4051 does not introduce lags on the short timescales associated with reverberation, but will likely modify the hard continuum lags seen on longer timescales, which in this source have been measured to be on the order of 50 s. Hence, these

  18. Shock-Absorbent Ball-Screw Mechanism

    Science.gov (United States)

    Hirr, Otto A., Jr.; Meneely, R. W.

    1986-01-01

    Actuator containing two ball screws in series employs Belleville springs to reduce impact loads, thereby increasing life expectancy. New application of springs increases reliability of equipment in which ball screws commonly used. Set of three springs within lower screw of ball-screw mechanism absorbs impacts that result when parts reach their upper and lower limits of movement. Mechanism designed with Belleville springs as shock-absorbing elements because springs have good energy-to-volume ratio and easily stacked to attain any stiffness and travel.

  19. Spin Particle in an Absorbing Environment

    Science.gov (United States)

    Amooshahi, M.

    2015-10-01

    The quantum dynamics of a localized spin Particle interacting with an absorbing environment is investigated. The quantum Langevin-Schrödinger equation for spin is obtained. The susceptibility function of the environment is calculated in terms of the coupling function of the spin and the environment. it is shown that the susceptibility function satisfies the Kramers-Kronig relations. Spontaneous emission and the shift frequency of the spin is obtained in terms of the imaginary part of the susceptibility function in frequency domain. Some transition probabilities between the spin states are calculated when the absorbing environment is in the thermal state.

  20. Quantum walk with one variable absorbing boundary

    Science.gov (United States)

    Wang, Feiran; Zhang, Pei; Wang, Yunlong; Liu, Ruifeng; Gao, Hong; Li, Fuli

    2017-01-01

    Quantum walks constitute a promising ingredient in the research on quantum algorithms; consequently, exploring different types of quantum walks is of great significance for quantum information and quantum computation. In this study, we investigate the progress of quantum walks with a variable absorbing boundary and provide an analytical solution for the escape probability (the probability of a walker that is not absorbed by the boundary). We simulate the behavior of escape probability under different conditions, including the reflection coefficient, boundary location, and initial state. Moreover, it is also meaningful to extend our research to the situation of continuous-time and high-dimensional quantum walks.

  1. Regulation of multiple carbon monoxide consumption pathways in anaerobic bacteria

    Directory of Open Access Journals (Sweden)

    Stephen M Techtmann

    2011-07-01

    Full Text Available Carbon monoxide (CO, well known as a toxic gas, is increasingly recognized as a key metabolite and signaling molecule. Microbial utilization of CO is quite common, evidenced by the rapid escalation in description of new species of CO-utilizing bacteria and archaea. Carbon monoxide dehydrogenase (CODH, the protein complex that enables anaerobic CO utilization has been well-characterized from an increasing number of microorganisms, however the regulation of multiple CO-related gene clusters in single isolates remains unexplored. Many species are extroraordinarily resistant to high CO concentrations, thiriving under pure CO at more than one atmosphere. We hypothesized that, in strains that can grow exclusively on CO, both carbon acquisition via the CODH/Acetyl CoA synthase complex and energy conservation via a CODH-linked hydrogenase must be differentially regulated in response to the availability of CO. The CO-sensing transcriptional activator, CooA is present in most CO-oxidizing bacteria. Here we present a genomic and phylogenetic survey of CODH operons and cooA genes found in CooA-containing bacteria. Two distinct groups of CooA homologs were found: One clade (CooA-1 is found in the majority of CooA containing bacteria, whereas the other clade (CooA-2 is found only in genomes that encode multiple CODH clusters, suggesting that the CooA-2 might be important for cross-regulation of competing CODH operons. Recombinant CooA-1 and CooA-2 regulators from the prototypical CO-utilizing bacterium Carboxydothermus hydrogenoformans were purified, and promoter binding analyses revealed that CooA-1 specifically regulates the hydrogenase-linked CODH, whereas CooA-2 is able to regulate both the hydrogenase-linked CODH and the CODH/ACS operons. These studies point to the ability of dual CooA homologs to partition CO into divergent CO-utilizing pathways resulting in efficient consumption of a single limiting growth substrate available across a wide range of

  2. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    Science.gov (United States)

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  3. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    OpenAIRE

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate us...

  4. Delayed neuropsychiatric syndrome after carbon monoxide poisoning: inclusion of hyperbaric oxygen therapy in the recovery protocol

    OpenAIRE

    Dante Lo Pardo; Davide Amedola; Giuliana Senatore; Alberto Damiano; Gabriela Pezzuti; Nicola Pugliese; Gianpiero Locatelli; Alfredo Siani; Nicola Maria Vitola

    2016-01-01

    The delayed neuropsychiatric syndrome can arise in the period from 4 days to 5 weeks following carbon monoxide poisoning, and is characterized by neuropsychological deficits, which in some cases become chronic. This case report describes an adult female who apparently suffered self-inflicted carbon monoxide poisoning. She was not treated with hyperbaric oxygen and developed delayed sequelae on day 20. The treatment started with 40 sessions of hyperbaric oxygen therapy and subsequently with ne...

  5. The Range of 1-3 keV Electrons in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Oehlenschlæger, M.; Andersen, H.H.; Schou, Jørgen

    1985-01-01

    The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than...... that in nitrogen whereas the range in carbon monoxide is about 20% larger than that in the nitrogen....

  6. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  7. 21 CFR 880.6025 - Absorbent tipped applicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbent tipped applicator. 880.6025 Section 880... Devices § 880.6025 Absorbent tipped applicator. (a) Identification. An absorbent tipped applicator is a device intended for medical purposes that consists of an absorbent swab on a wooden, paper, or...

  8. 21 CFR 880.5300 - Medical absorbent fiber.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical absorbent fiber. 880.5300 Section 880.5300... Devices § 880.5300 Medical absorbent fiber. (a) Identification. A medical absorbent fiber is a device...'s body surface. Absorbent fibers intended solely for cosmetic purposes are not included in...

  9. Carbon monoxide exposure in households in Ciudad Juárez, México.

    Science.gov (United States)

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value <0.01). Heater type may be a stronger determinant of exposure, as households with a particular heater model (the El Sol FM-210) were significantly more likely to be among the more highly exposed households (odds ratio of 4.8, p-value of 0.02). A variety of health effects were pooled and found at elevated frequency in the households that exceeded the 8-h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  10. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction.

    Science.gov (United States)

    Xu, Jiajun; Yang, Ming; Kosterin, Paul; Salzberg, Brian M; Milovanova, Tatyana N; Bhopale, Veena M; Thom, Stephen R

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries.

  11. Carbon monoxide: from toxin to endogenous modulator of cardiovascular functions

    Directory of Open Access Journals (Sweden)

    R.A. Johnson

    1999-01-01

    Full Text Available Carbon monoxide (CO is a pollutant commonly recognized for its toxicological attributes, including CNS and cardiovascular effects. But CO is also formed endogenously in mammalian tissues. Endogenously formed CO normally arises from heme degradation in a reaction catalyzed by heme oxygenase. While inhibitors of endogenous CO production can raise arterial pressure, heme loading can enhance CO production and lead to vasodepression. Both central and peripheral tissues possess heme oxygenases and generate CO from heme, but the inability of heme substrate to cross the blood brain barrier suggests the CNS heme-heme oxygenase-CO system may be independent of the periphery. In the CNS, CO apparently acts in the nucleus tractus solitarii (NTS promoting changes in glutamatergic neurotransmission and lowering blood pressure. At the periphery, the heme-heme oxygenase-CO system can affect cardiovascular functions in a two-fold manner; specifically: 1 heme-derived CO generated within vascular smooth muscle (VSM can promote vasodilation, but 2 its actions on the endothelium apparently can promote vasoconstriction. Thus, it seems reasonable that the CNS-, VSM- and endothelial-dependent actions of the heme-heme oxygenase-CO system may all affect cardiac output and vascular resistance, and subsequently blood pressure.

  12. Acute carbon monoxide poisoning: animal models: a review.

    Science.gov (United States)

    Penney, D G

    1990-05-31

    Animals have been used for well over a century in an attempt to understand the toxicology, physiology, and pathology of acute carbon monoxide poisoning. Whether the toxic effects of this gas result from primary hypoxia, as in hypoxic hypoxia to which it is frequently compared, or from direct tissue effects since it enters cells and binds to certain vital components, remains a point of controversy. Acute severe poisoning in man and animals affects primarily the cardiovascular and nervous systems, and frequently produces neurologic dysfunction. Morphologically, tissue damage is usually confined to the white matter. The root cause is at best poorly understood and major investigative efforts have been made toward its elucidation. Many studies with rats, cats and primates indicate a major role for CO-induced hypotension, which serves to compromise blood flow and exacerbate acidosis. The likely cellular mechanisms in this process are only now becoming apparent. This review critically examines the recent as well as a few older CO-animal studies. In scope, they fall into several broad categories: general cardiopulmonary effects, metabolic and tissue effects, general resistance (i.e. tolerance), effects on the central nervous system including blood flow, neurochemistry, morphology and behavior, and finally, experimental therapeutic approaches.

  13. The Role of Oxygen Therapies in Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Suleyman Metin

    2011-08-01

    Full Text Available Due to climate and socio-economic issues in Turkey, the incidence of carbon monoxide (CO poisoning is high, especially in winter. Clinical manifestations may vary depending on the type of CO source, concentration and duration of exposure. The symptoms of CO poisoning predominantly manifest in lots of organs and systems with high oxygen utilization, especially the brain and the heart. The primary aim in oxygen therapy is to eliminate CO and to reduce its toxic effects. In this context, normobaric and hyperbaric oxygen therapy are used to achieve these goals. Normobaric oxygen (NBO treatment is an easily accessible and relatively not expensive modality, where hyperbaric oxygen (HBO therapy requires specific equipment, certified staff and is available only in some centers. Additionally, HBO treatment has several additional advantages over NBO treatment. Despite its benefits, it is compulsory to search for some criteria in selecting patients to be treated because of the limited availability and access of hyperbaric facilities. For an effective evaluation and an optimal treatment, advanced education of the healthcare professionals on the use of oxygen delivery modalities in the management of CO poisoning is imperative. In this review, it has been aimed to outline the significance of oxygen treatment modalities and to determine patient selection criteria for HBO treatment in the management of CO poisoning which continues to be an important threat to community health care. [TAF Prev Med Bull 2011; 10(4.000: 487-494

  14. Carbon monoxide exposures after hurricane Ike - Texas, September 2008.

    Science.gov (United States)

    2009-08-14

    During power outages after hurricanes, survivors can be at risk for carbon monoxide (CO) poisoning if they use portable generators improperly. On September 13, 2008, Hurricane Ike struck the coast of Texas, leaving approximately 2.3 million households in the southeastern portion of the state without electricity. Six days later, 1.3 million homes were still without electrical power. To assess the impact of storm-related CO exposures and to enhance prevention efforts, CDC analyzed data from five disparate surveillance sources on CO exposures reported during September 13--26 in counties of southeast Texas that were declared disaster areas by the federal government. This report describes the results of that analysis, which indicated that one data source, Texas poison centers, received reports of 54 persons with storm-related CO exposures during the surveillance period. Another data source, the Undersea and Hyperbaric Medical Society (UHMS) hyperbaric oxygen treatment database, reported that 15 persons received hyperbaric oxygen treatment for storm-related CO poisoning. Medical examiners, public health officials, and hospitals in Texas reported that seven persons died from storm-related CO poisoning. Among the data sources, the percentage of reported storm-related CO exposures caused by improper generator use ranged from 82% to 87%. These findings underscore the need for effective prevention messages during storm preparation, warnings, and response periods regarding the correct use of generators and the installation and maintenance of battery-powered CO detectors.

  15. The immunomodulatory role of carbon monoxide during transplantation

    Directory of Open Access Journals (Sweden)

    Amano Mariane

    2013-01-01

    Full Text Available Abstract The number of organ and tissue transplants has increased worldwide in recent decades. However, graft rejection, infections due to the use of immunosuppressive drugs and a shortage of graft donors remain major concerns. Carbon monoxide (CO had long been regarded solely as a poisonous gas. Ultimately, physiological studies unveiled the endogenous production of CO, particularly by the heme oxygenase (HO-1 enzyme, recognizing CO as a beneficial gas when used at therapeutic doses. The protective properties of CO led researchers to develop uses for it, resulting in devices and molecules that can deliver CO in vitro and in vivo. The resulting interest in clinical investigations was immediate. Studies regarding the CO/HO-1 modulation of immune responses and their effects on various immune disorders gave rise to transplantation research, where CO was shown to be essential in the protection against organ rejection in animal models. This review provides a perspective of how CO modulates the immune system to improve transplantation and suggests its use as a therapy in the field.

  16. Carbon monoxide and iron modulate plasmatic coagulation in Alzheimer's disease.

    Science.gov (United States)

    Nielsen, Vance G; Pretorius, Etheresia; Bester, Janette; Jacobsen, Wayne K; Boyle, Patrick K; Reinhard, Joao P

    2015-01-01

    Alzheimer's disease (AD) is a significant source of morbidity and mortality for millions of people worldwide, and multiple potential etiologies have been postulated to contribute to AD. Among these, spontaneous cerebral emboli and increased cerebral and circulating heme oxygenase (Hmox) activity in AD patients are of particular interest, as two of the products of Hmox activity, carbon monoxide (CO) and iron enhance plasmatic coagulation and modify the ultrastructure of thrombi. We hypothesized that patients afflicted with AD would have coagulation kinetics modulated by CO and iron. Using viscoelastic assessments of coagulation, it was determined with a small cohort (n=11) of AD patients that all had enhancement of coagulation by CO, iron, or both. In a complementary fashion, it was determined that a separate cohort (n=12) of AD patients had thrombi with ultrastructural features consistent with iron and CO exposure as assessed with scanning electron microscopy. Further, when stratified by normal or abnormally increased serum ferritin concentrations (which can be increased by Hmox), the AD patients with abnormal ferritin concentrations had significantly thinner fibrin fiber diameters, not unlike that noted when normal plasma is mixed with iron or CO. In sum, AD patients were noted to have plasmatic coagulation kinetic and thrombus ultrastructural changes consistent with exposure to CO and iron. Future investigation of CO and iron in the pathogenesis of Alzheimer's disease is warranted.

  17. Density-functional study of plutonium monoxide monohydride

    Science.gov (United States)

    Qiu, Ruizhi; Lu, Haiyan; Ao, Bingyun; Tang, Tao; Chen, Piheng

    2017-03-01

    The structural, electronic, mechanical, optical, thermodynamic properties of plutonium monoxide monohydride (PuOH) are studied by density-functional calculations within the framework of LDA/GGA and LDA/GGA+U. From the total energy calculation, the lowest-energy crystal structure of PuOH is predicted to have space group F 4 bar 3 m (No. 216). Within the LDA+U framework, the calculated lattice parameter of F 4 bar 3 m -PuOH is in good agreement with the experimental value and the corresponding ground state is predicted to be an antiferromagnetic charge-transfer insulator. Furthermore, we investigate the bonding character of PuOH by analyzing the electron structure and find that there are a stronger Pu-O bond and a weaker Pu-H bond. The mechanical properties including the elastic constants, elastic moduli and Debye's temperature, and the optical properties including the reflectivity and absorption coefficient are also calculated. We then compute the phonon spectrum which verified the dynamical stability of F 4 bar 3 m -PuOH. Some thermodynamic quantities such as the specific heat are evaluated. Finally we calculate the formation energy of PuOH, and the reaction energies for the oxidation of PuOH and PuOH-coated Pu, which are in reasonable agreement with the experimental values.

  18. Carbon monoxide: an emerging regulator of ion channels.

    Science.gov (United States)

    Wilkinson, William J; Kemp, Paul J

    2011-07-01

    Carbon monoxide is rapidly emerging as an important cellular messenger, regulating a wide range of physiological processes. Crucial to its role in both physiology and disease is its ability differentially to regulate several classes of ion channels, including examples from calcium-activated K(+) (BK(Ca)), voltage-activated K(+) (K(v)) and Ca(2+) channel (L-type) families, ligand-gated P2X receptors (P2X2 and P2X4), tandem P domain K(+) channels (TREK1) and the epithelial Na(+) channel (ENaC). The mechanisms by which CO regulates these ion channels are still unclear and remain somewhat controversial. However, available structure-function studies suggest that a limited range of amino acid residues confer CO sensitivity, either directly or indirectly, to particular ion channels and that cellular redox state appears to be important to the final integrated response. Whatever the molecular mechanism by which CO regulates ion channels, endogenous production of this gasotransmitter has physiologically important roles and is currently being explored as a potential therapeutic.

  19. Discovery of carbon monoxide in the upper atmosphere of Pluto

    CERN Document Server

    Greaves, J S; Friberg, P

    2011-01-01

    Pluto's icy surface has changed colour and its atmosphere has swelled since its last closest approach to the Sun in 1989. The thin atmosphere is produced by evaporating ices, and so can also change rapidly, and in particular carbon monoxide should be present as an active thermostat. Here we report the discovery of gaseous CO via the 1.3mm wavelength J=2-1 rotational transition, and find that the line-centre signal is more than twice as bright as a tentative result obtained by Bockelee-Morvan et al. in 2000. Greater surface-ice evaporation over the last decade could explain this, or increased pressure could have caused the atmosphere to expand. The gas must be cold, with a narrow line-width consistent with temperatures around 50 K, as predicted for the very high atmosphere, and the line brightness implies that CO molecules extend up to approximately 3 Pluto radii above the surface. The upper atmosphere must have changed markedly over only a decade since the prior search, and more alterations could occur by the...

  20. Regulation of ROS Production and Vascular Function by Carbon Monoxide

    Directory of Open Access Journals (Sweden)

    Yoon Kyung Choi

    2012-01-01

    Full Text Available Carbon monoxide (CO is a gaseous molecule produced from heme by heme oxygenase (HO. CO interacts with reduced iron of heme-containing proteins, leading to its involvement in various cellular events via its production of mitochondrial reactive oxygen species (ROS. CO-mediated ROS production initiates intracellular signal events, which regulate the expression of adaptive genes implicated in oxidative stress and functions as signaling molecule for promoting vascular functions, including angiogenesis and mitochondrial biogenesis. Therefore, CO generated either by exogenous delivery or by HO activity can be fundamentally involved in regulating mitochondria-mediated redox cascades for adaptive gene expression and improving blood circulation (i.e., O2 delivery via neovascularization, leading to the regulation of mitochondrial energy metabolism. This paper will highlight the biological effects of CO on ROS generation and cellular redox changes involved in mitochondrial metabolism and angiogenesis. Moreover, cellular mechanisms by which CO is exploited for disease prevention and therapeutic applications will also be discussed.

  1. Heme oxygenase-1 and carbon monoxide in pulmonary medicine.

    Science.gov (United States)

    Slebos, Dirk-Jan; Ryter, Stefan W; Choi, Augustine M K

    2003-01-01

    Heme oxygenase-1 (HO-1), an inducible stress protein, confers cytoprotection against oxidative stress in vitro and in vivo. In addition to its physiological role in heme degradation, HO-1 may influence a number of cellular processes, including growth, inflammation, and apoptosis. By virtue of anti-inflammatory effects, HO-1 limits tissue damage in response to proinflammatory stimuli and prevents allograft rejection after transplantation. The transcriptional upregulation of HO-1 responds to many agents, such as hypoxia, bacterial lipopolysaccharide, and reactive oxygen/nitrogen species. HO-1 and its constitutively expressed isozyme, heme oxygenase-2, catalyze the rate-limiting step in the conversion of heme to its metabolites, bilirubin IXalpha, ferrous iron, and carbon monoxide (CO). The mechanisms by which HO-1 provides protection most likely involve its enzymatic reaction products. Remarkably, administration of CO at low concentrations can substitute for HO-1 with respect to anti-inflammatory and anti-apoptotic effects, suggesting a role for CO as a key mediator of HO-1 function. Chronic, low-level, exogenous exposure to CO from cigarette smoking contributes to the importance of CO in pulmonary medicine. The implications of the HO-1/CO system in pulmonary diseases will be discussed in this review, with an emphasis on inflammatory states.

  2. Heme oxygenase-1 and carbon monoxide in pulmonary medicine

    Directory of Open Access Journals (Sweden)

    Choi Augustine MK

    2003-08-01

    Full Text Available Abstract Heme oxygenase-1 (HO-1, an inducible stress protein, confers cytoprotection against oxidative stress in vitro and in vivo. In addition to its physiological role in heme degradation, HO-1 may influence a number of cellular processes, including growth, inflammation, and apoptosis. By virtue of anti-inflammatory effects, HO-1 limits tissue damage in response to proinflammatory stimuli and prevents allograft rejection after transplantation. The transcriptional upregulation of HO-1 responds to many agents, such as hypoxia, bacterial lipopolysaccharide, and reactive oxygen/nitrogen species. HO-1 and its constitutively expressed isozyme, heme oxygenase-2, catalyze the rate-limiting step in the conversion of heme to its metabolites, bilirubin IXα, ferrous iron, and carbon monoxide (CO. The mechanisms by which HO-1 provides protection most likely involve its enzymatic reaction products. Remarkably, administration of CO at low concentrations can substitute for HO-1 with respect to anti-inflammatory and anti-apoptotic effects, suggesting a role for CO as a key mediator of HO-1 function. Chronic, low-level, exogenous exposure to CO from cigarette smoking contributes to the importance of CO in pulmonary medicine. The implications of the HO-1/CO system in pulmonary diseases will be discussed in this review, with an emphasis on inflammatory states.

  3. Heme oxygenase-1/carbon monoxide: from metabolism to molecular therapy.

    Science.gov (United States)

    Ryter, Stefan W; Choi, Augustine M K

    2009-09-01

    Heme oxygenase-1 (HO-1), a ubiquitous inducible stress-response protein, serves a major metabolic function in heme turnover. HO activity cleaves heme to form biliverdin-IXalpha, carbon monoxide (CO), and iron. Genetic experiments have revealed a central role for HO-1 in tissue homeostasis, protection against oxidative stress, and in the pathogenesis of disease. Four decades of research have witnessed not only progress in elucidating the molecular mechanisms underlying the regulation and function of this illustrious enzyme, but also have opened remarkable translational applications for HO-1 and its reaction products. CO, once regarded as a metabolic waste, can act as an endogenous mediator of cellular signaling and vascular function. Exogenous application of CO by inhalation or pharmacologic delivery can confer cytoprotection in preclinical models of lung/vascular injury and disease, based on anti-apoptotic, anti-inflammatory, and anti-proliferative properties. The bile pigments, biliverdin and bilirubin, end products of heme degradation, have also shown potential as therapeutics in vascular disease based on anti-inflammatory and anti-proliferative activities. Further translational and clinical trials research will unveil whether the HO-1 system or any of its reaction products can be successfully applied as molecular medicine in human disease.

  4. Carbon Monoxide Binding by Hemoglobin and Myoglobin under Photodissociating Conditions

    Science.gov (United States)

    Brunori, Maurizio; Bonaventura, Joseph; Bonaventura, Celia; Antonini, Eraldo; Wyman, Jeffries

    1972-01-01

    Carbon monoxide binding by myoglobin and hemoglobin has been studied under conditions of constant illumination. For hemoglobin, the homotropic heme-heme interaction (cooperativity) and the heterotropic Bohr effect are invariant with light intensity over a 1000-fold change of c½. The dissociation constant, measured as c½, increases linearly with light intensity, indicating that photodissociation is a one-quantum process. At sufficiently high illumination the apparent enthalpy of ligand binding becomes positive, although in the absence of light it is known to be negative. This finding indicates that light acts primarily by increasing the “off” constants by an additive factor. The invariance of both cooperativity and Bohr effect raises a perplexing issue. It would appear to demand either that the “off” constants for the various elementary steps are all alike (which is contrary to current ideas) or that the additive factor is in each case proportional to the particular “off” constant to which it is added (a seemingly improbable alternative). PMID:4502938

  5. In-utero carbon monoxide poisoning and multiple fetal abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Hennequin, Y.; Blum, D.; Vamos, E.; Steppe, M.; Goedseels, J.; Cavatorta, E. (Free Univ. of Brussels (Belgium). Queen Fabiola Children' s Hospital)

    1993-01-23

    Carbon monoxide (CO) poisoning during pregnancy can lead to feto-maternal fatalities and stillbirths. Teratogenic effects have been reported. The authors strongly suspected an association between mild but chronic CO poisoning of the mother and major multiple malformations in the baby. Retrospective interviews of the mother disclosed that at 10 weeks' gestation, she had complained of headache and dizziness. At the same time, her 16-month-old daughter had an episode of unconsciousness. A faulty kitchen gas water-heater was suspected but the family did not have it repaired. The mother continued to have headaches regularly. During the 7th month of pregnancy, the daughter was found comatose. In the emergency ward, carboxyhemoglobins levels were 27.5% for the child and 14% for the pregnant mother. Both were treated with hyperbaric oxygen. Investigations by the gas company revealed a highly abnormal CO production from the kitchen and bathroom gas-water heaters: 120 and 100 parts per million, respectively, after 2 minutes of use.

  6. Effect of water on carbon monoxide-oxygen flame velocity

    Science.gov (United States)

    Mcdonald, Glen E

    1954-01-01

    The flame velocities were measured of 20 percent oxygen and 80 percent carbon monoxide mixtures containing either light water or heavy water. The flame velocity increased from 34.5 centimeters per second with no added water to about 104 centimeters per second for a 1.8 percent addition of light water and to 84 centimeters per second for an equal addition of heavy water. The addition of heavy water caused greater increases in flame velocity with equilibrium hydrogen-atom concentration than would be predicted by the Tanford and Pease square-root relation. The ratio of the flame velocity of a mixture containing light water to that of a mixture containing heavy water was found to be 1.4. This value is the same as the ratio of the reaction rate of hydrogen to that of deuterium and oxygen. A ratio of reaction rates of 1.4 would also be required for the square-root law to give the observed ratio of flame-velocity changes.

  7. Tsukamurella carboxydivorans sp. nov., a carbon monoxide-oxidizing actinomycete.

    Science.gov (United States)

    Park, Sae W; Kim, Sung M; Park, Sang T; Kim, Young M

    2009-06-01

    A Gram-positive, slightly acid-alcohol-fast, carbon monoxide-oxidizing bacterium, strain Y2(T), was isolated from a soil sample collected from a roadside in Seoul, Korea. On the basis of 16S rRNA gene sequence comparative analyses, strain Y2(T) was shown to belong to the genus Tsukamurella and was most closely related to Tsukamurella tyrosinosolvens DSM 44234(T) (GenBank accession no. AY238514; 99.8 %). The predominant fatty acids were C(18 : 1)omega9c and C(16 : 0). The cell-wall peptidoglycan of strain Y2(T) contained meso-diaminopimelic acid as the diagnostic diamino acid. Strain Y2(T) contained galactose and arabinose as the whole cell sugars. The DNA G+C content was 77 mol%. The DNA-DNA relatedness value between strain Y2(T) and T. tyrosinosolvens DSM 44234(T) was 62.7 %. Based on the combination of the carbon source utilization pattern, fatty acid profile, cell-wall chemotype, DNA G+C content and DNA-DNA hybridization experiments, it is proposed that strain Y2(T) (=KCCM 42885(T)=JCM 15482(T)) represents the type strain of a novel species, Tsukamurella carboxydivorans sp. nov.

  8. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    Science.gov (United States)

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  9. Mopra Central Molecular Zone Carbon Monoxide Survey Status

    Science.gov (United States)

    Blackwell, Rebecca; Burton, Michael; Rowell, Gavin

    2017-01-01

    We present an update on the Mopra Central Molecular Zone Carbon Monoxide (CO) survey, with data taken in 2016 extending the original 3.5° >= l >= 358.5°, +1.0° >= b >= -0.5° to 4.0° >= l >= 358.0°, +1.0° >= b >= -1.0°. Using the four simultaneously observed lines of 12CO, 13CO, C18O, and C17O Nyquist sampled at 0.6' spatial and 0.1 km/s spectral resolution, we are building an optical-thickness-corrected three-dimensional model of the diffuse gas, and making cloud mass estimates. This data, as part of the Mopra Southern Galactic Plane CO Survey (Braiding et al. (2015), Burton et al. (2013)), is at the highest resolution available across such a widespread region, and includes the Sagittarius A, Sagittarius B2, Sagittarius C, and G1.3 cloud complexes, as well as Bania's Clump 2.

  10. Gene expression in rat striatum following carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Shuichi Hara

    2017-06-01

    Full Text Available Carbon monoxide (CO poisoning causes brain damage, which is attenuated by treatment with hydrogen [1,2], a scavenger selective to hydroxyl radical (·≡OH [3]. This suggests a role of ·≡OH in brain damage due to CO poisoning. Studies have shown strong enhancement of ·≡OH production in rat striatum by severe CO poisoning with a blood carboxyhemoglobin (COHb level >70% due to 3000 ppm CO, but not less severe CO poisoning with a blood COHb level at approximately 50% due to 1000 ppm CO [4]. Interestingly, 5% O2 causes hypoxia comparable with that by 3000 ppm CO and produces much less •OH than 3000 ppm CO does [4]. In addition, cAMP production in parallel with ·≡OH production [5] might contribute to ·≡OH production [6]. It is likely that mechanisms other than hypoxia contribute to brain damage due to CO poisoning [7]. To search for the mechanisms, we examined the effects of 1000 ppm CO, 3000 ppm CO and 5% O2 on gene expression in rat striatum. All array data have been deposited in the Gene Expression Omnibus (GEO database under accession number GSE94780.

  11. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor

    Directory of Open Access Journals (Sweden)

    Chen-Chia Chen

    2016-09-01

    Full Text Available Carbon monoxide (CO poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB (2.5 W at a flow rate of 4.2 L/min, and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline.

  12. Carbon monoxide: silent killer and expert imitator (Part I

    Directory of Open Access Journals (Sweden)

    Valeria Petrolini

    2008-02-01

    Full Text Available Carbon monoxide is still the most common unintentional poisoning in the Western Countries, and it may often produce potentially serious or lethal acute and delayed clinical manifestations. The considerable variety of symptoms of presentation is the principal reason of the non infrequent diagnostic errors at admission. In emergency medicine it is essential to consider this diagnosis every time a patient is found in state of unconsciousness in an environment with possible exposure to CO, as well as in patients presenting with non-specific syndromes. The prompt identification of the intoxication is essential in order to plan a correct therapy at the proper time, and for prevention of risks of a late neurologic syndrome. Nowadays the diagnosis may be performed through determination of COHb in a fast and non-invasive way, both outside and inside hospitals, thanks to a new generation of specific pulsoxymetrers. After confirmation the patient has to be classified with a grading score for severity depending on clinical presentation, that may be useful also for the choice between normobaric or hyperbaric oxygen treatments. Eventually, it is essential to plan the follow up for the patient during the months following the acute event.

  13. Carbon monoxide: silent killer and expert imitator (Part II

    Directory of Open Access Journals (Sweden)

    Valeria Petrolini

    2008-04-01

    Full Text Available Carbon monoxide is still the most common unintentional poisoning in the Western Countries, and it may often produce potentially serious or lethal acute and delayed clinical manifestations. The considerable variety of symptoms of presentation is the main reason of the non infrequent diagnostic errors at admission. In emergency medicine it is essential to consider this diagnosis every time a patient is found in state of unconsciousness in an environment with possible exposure to CO, as well as in patients presenting with non-specific syndromes. The prompt identification of the intoxication is essential in order to plan a correct therapy at the proper time, and for preventing of risks of a late neurologic syndrome. After confirmation of the diagnosis through determination of COHb, that may nowadays be performed in a fast and non-invasive way both outside and inside hospitals thanks to a new generation of specific pulsoxyimeters, the patient has to be classified with a grading score for the severity depending on clinical presentation, that may be useful also for choice between normobaric or hyperbaric oxygen treatments. Eventually, it is essential to plan the follow-up for the patient during the months following the acute event.

  14. Tunable metamaterial dual-band terahertz absorber

    Science.gov (United States)

    Luo, C. Y.; Li, Z. Z.; Guo, Z. H.; Yue, J.; Luo, Q.; Yao, G.; Ji, J.; Rao, Y. K.; Li, R. K.; Li, D.; Wang, H. X.; Yao, J. Q.; Ling, F. R.

    2015-11-01

    We report a design of a temperature controlled tunable dual band terahertz absorber. The compact single unit cell consists of two nested closed square ring resonators and a layer metallic separated by a substrate strontium titanate (STO) dielectric layer. It is found that the absorber has two distinctive absorption peaks at frequencies 0.096 THz and 0.137 THz, whose peaks are attained 97% and 75%. Cooling the absorber from 400 K to 250 K causes about 25% and 27% shift compared to the resonance frequency of room temperature, when we cooling the temperature to 150 K, we could attained both the two tunabilities exceeding 53%. The frequency tunability is owing to the variation of the dielectric constant of the low-temperature co-fired ceramic (LTCC) substrate. The mechanism of the dual band absorber is attributed to the overlapping of dual resonance frequencies, and could be demonstrated by the distributions of the electric field. The method opens up avenues for designing tunable terahertz devices in detection, imaging, and stealth technology.

  15. Review of Plasmonic Nanocomposite Metamaterial Absorber

    Directory of Open Access Journals (Sweden)

    Mehdi Keshavarz Hedayati

    2014-02-01

    Full Text Available Plasmonic metamaterials are artificial materials typically composed of noble metals in which the features of photonics and electronics are linked by coupling photons to conduction electrons of metal (known as surface plasmon. These rationally designed structures have spurred interest noticeably since they demonstrate some fascinating properties which are unattainable with naturally occurring materials. Complete absorption of light is one of the recent exotic properties of plasmonic metamaterials which has broadened its application area considerably. This is realized by designing a medium whose impedance matches that of free space while being opaque. If such a medium is filled with some lossy medium, the resulting structure can absorb light totally in a sharp or broad frequency range. Although several types of metamaterials perfect absorber have been demonstrated so far, in the current paper we overview (and focus on perfect absorbers based on nanocomposites where the total thickness is a few tens of nanometer and the absorption band is broad, tunable and insensitive to the angle of incidence. The nanocomposites consist of metal nanoparticles embedded in a dielectric matrix with a high filling factor close to the percolation threshold. The filling factor can be tailored by the vapor phase co-deposition of the metallic and dielectric components. In addition, novel wet chemical approaches are discussed which are bio-inspired or involve synthesis within levitating Leidenfrost drops, for instance. Moreover, theoretical considerations, optical properties, and potential application of perfect absorbers will be presented.

  16. Microstructured extremely thin absorber solar cells

    DEFF Research Database (Denmark)

    Biancardo, Matteo; Krebs, Frederik C

    2007-01-01

    In this paper we present the realization of extremely thin absorber (ETA) solar cells employing conductive glass substrates functionalized with TiO2 microstructures produced by embossing. Nanocrystalline or compact TiO2 films on Indium doped tin oxide (ITO) glass substrates were embossed...

  17. Methods of calculating radiation absorbed dose.

    Science.gov (United States)

    Wegst, A V

    1987-01-01

    The new tumoricidal radioactive agents being developed will require a careful estimate of radiation absorbed tumor and critical organ dose for each patient. Clinical methods will need to be developed using standard imaging or counting instruments to determine cumulated organ activities with tracer amounts before the therapeutic administration of the material. Standard MIRD dosimetry methods can then be applied.

  18. Can polar bear hairs absorb environmental energy?

    Directory of Open Access Journals (Sweden)

    He Ji-Huan

    2011-01-01

    Full Text Available A polar bear (Ursus maritimus has superior ability to survive in harsh Arctic regions, why does the animal have such an excellent thermal protection? The present paper finds that the unique labyrinth cavity structure of the polar bear hair plays an important role. The hair can not only prevent body temperature loss but can also absorb energy from the environment.

  19. Timing the warm absorber in NGC 4051

    CERN Document Server

    Silva, Catia; Costantini, Elisa

    2016-01-01

    We investigated, using spectral-timing analysis, the characterization of highly ionized outflows in Seyfert galaxies, the so-called warm absorbers. Here, we present our results on the extensive ~ 600 ks of XMM-Newton archival observations of the bright and highly variable Seyfert 1 galaxy NGC 4051, whose spectrum has revealed a complex multicomponent wind. Making use of both RGS and EPIC-pn data, we performed a detailed analysis through a time-dependent photoionization code in combination with spectral and Fourier spectral-timing techniques. The source light curves and the warm absorber parameters obtained from the data were used to simulate the response of the gas due to variations in the ionizing flux of the central source. The resulting time variable spectra were employed to predict the effects of the warm absorber on the time lags and coherence of the energy dependent light curves. We have found that, in the absence of any other lag mechanisms, a warm absorber with the characteristics of the one observed ...

  20. Can polar bear hairs absorb environmental energy?

    OpenAIRE

    He Ji-Huan; Wang Qing-Li; Sun Jie

    2011-01-01

    A polar bear (Ursus maritimus) has superior ability to survive in harsh Arctic regions, why does the animal have such an excellent thermal protection? The present paper finds that the unique labyrinth cavity structure of the polar bear hair plays an important role. The hair can not only prevent body temperature loss but can also absorb energy from the environment.

  1. Fabrication of high efficacy selective solar absorbers

    CSIR Research Space (South Africa)

    Tile, N

    2012-03-01

    Full Text Available High efficiency tandem selective solar absorber materials of carbon in nickel oxide (C-NiO) composite were fabricated on an aluminium substrate using a simple and cost effective sol-gel process. The process involved preparation of carbon and nickel...

  2. Moving core beam energy absorber and converter

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2012-12-18

    A method and apparatus for the prevention of overheating of laser or particle beam impact zones through the use of a moving-in-the-coolant-flow arrangement for the energy absorbing core of the device. Moving of the core spreads the energy deposition in it in 1, 2, or 3 dimensions, thus increasing the effective cooling area of the device.

  3. Semiconductor saturable absorbers for ultrafast terahertz signals

    DEFF Research Database (Denmark)

    Hoffmann, Matthias C.; Turchinovich, Dmitry

    2010-01-01

    We demonstrate saturable absorber behavior of n-type semiconductors GaAs, GaP, and Ge in the terahertz THz frequency range at room temperature using nonlinear THz spectroscopy. The saturation mechanism is based on a decrease in electron conductivity of semiconductors at high electron momentum sta...

  4. Aircraft-borne DOAS limb observations of iodine monoxide around Borneo

    Science.gov (United States)

    Großmann, Katja; Hossaini, Ryan; Mantle, Hannah; Chipperfield, Martyn; Wittrock, Folkard; Peters, Enno; Lampel, Johannes; Walker, Hannah; Heard, Dwayne; Krystofiak, Gisèle; Catoire, Valéry; Dorf, Marcel; Werner, Bodo; Pfeilsticker, Klaus

    2015-04-01

    Iodine monoxide (IO) has a major impact on the photochemistry of the troposphere. It can for example catalytically destroy ozone, influence the atmospheric oxidation capacity by changing the partitioning of the HOx and NOx species, or contribute to the formation of ultrafine particles. Information regarding the vertical distribution of IO is still sparse since only few vertical profiles of IO exist for the troposphere. Spectroscopic measurements were carried out from aboard the research aircraft DLR-Falcon during the SHIVA (Stratospheric ozone: Halogen Impacts in a Varying Atmosphere) campaign at Malaysian Borneo in November and December 2011 to study the abundance and transport of trace gases in the lower atmosphere. Sixteen research flights were performed covering legs near the surface in the marine boundary layer (MBL) as well as in the free troposphere (FT) up to an altitude of 13 km. The spectroscopic measurements were evaluated using the Differential Optical Absorption Spectroscopy (DOAS) technique in limb geometry, which supports observations of UV/visible absorbing trace gases, such as O4, BrO, IO, NO2, HCHO, CHOCHO, HONO and H2O, and altitude information was gained via the O4 scaling technique and/or full inversion. The inferred vertical profiles of IO showed mixing ratios of 0.5-1.5 ppt in the MBL, which decreased to 0.1-0.3 ppt in the FT. Occasionally, the IO observed in the FT of the marine environment coincided with elevated amounts of CO, but no IO was observed over land, neither in the boundary layer, nor in the FT. This behavior strongly indicated that the major sources for IO were organic and inorganic precursor molecules emitted from the ocean, which during daytime rapidly formed a sizable amount of IO in the MBL that was occasionally transported into the FT where efficient loss processes for IO must exist. The inferred vertical profiles of IO are compared to simulations using the global 3-D chemistry transport model TOMCAT including recent fluxes

  5. ELECTRONS IN NONPOLAR LIQUIDS.

    Energy Technology Data Exchange (ETDEWEB)

    HOLROYD,R.A.

    2002-10-22

    Excess electrons can be introduced into liquids by absorption of high energy radiation, by photoionization, or by photoinjection from metal surfaces. The electron's chemical and physical properties can then be measured, but this requires that the electrons remain free. That is, the liquid must be sufficiently free of electron attaching impurities for these studies. The drift mobility as well as other transport properties of the electron are discussed here as well as electron reactions, free-ion yields and energy levels, Ionization processes typically produce electrons with excess kinetic energy. In liquids during thermalization, where this excess energy is lost to bath molecules, the electrons travel some distance from their geminate positive ions. In general the electrons at this point are still within the coulombic field of their geminate ions and a large fraction of the electrons recombine. However, some electrons escape recombination and the yield that escapes to become free electrons and ions is termed G{sub fi}. Reported values of G{sub fi} for molecular liquids range from 0.05 to 1.1 per 100 eV of energy absorbed. The reasons for this 20-fold range of yields are discussed here.

  6. Absorbed fractions for electrons in ellipsoidal volumes

    Science.gov (United States)

    Amato, E.; Lizio, D.; Baldari, S.

    2011-01-01

    We applied a Monte Carlo simulation in Geant4 in order to calculate the absorbed fractions for monoenergetic electrons in the energy interval between 10 keV and 2 MeV, uniformly distributed in ellipsoids made from soft tissue. For each volume, we simulated a spherical shape, four oblate and four prolate ellipsoids, and one scalene shape. For each energy and for every geometrical configuration, an analytical relationship between the absorbed fraction and a 'generalized radius' was found, and the dependence of the fit parameters from electron energy is discussed and fitted by proper parametric functions. With the proposed formulation, the absorbed fraction for electrons in the 10-2000 keV energy range can be calculated for all volumes and for every ellipsoidal shape of practical interest. This method can be directly applied to evaluation of the absorbed fraction from the radionuclide emission of monoenergetic electrons, such as Auger or conversion electrons. The average deposited energy per disintegration in the case of extended beta spectra can be evaluated through integration. Two examples of application to a pure beta emitter such as 90Y and to 131I, whose emission include monoenergetic and beta electrons plus gamma photons, are presented. This approach represent a generalization of our previous studies, allowing a comprehensive treatment of absorbed fractions from electron and photon sources uniformly distributed in ellipsoidal volumes of any ellipticity and volume, in the whole range of practical interest for internal dosimetry in nuclear medicine applications, as well as in radiological protection estimations of doses from an internal contamination.

  7. Neutron absorbers and methods of forming at least a portion of a neutron absorber

    Science.gov (United States)

    Guillen, Donna P; Porter, Douglas L; Swank, W David; Erickson, Arnold W

    2014-12-02

    Methods of forming at least a portion of a neutron absorber include combining a first material and a second material to form a compound, reducing the compound into a plurality of particles, mixing the plurality of particles with a third material, and pressing the mixture of the plurality of particles and the third material. One or more components of neutron absorbers may be formed by such methods. Neutron absorbers may include a composite material including an intermetallic compound comprising hafnium aluminide and a matrix material comprising pure aluminum.

  8. Effect of carbon monoxide, hydrogen and sulfate on thermophilic (55°C) hydrogenogenic carbon monoxide conversion in two anaerobic bioreactor sludges

    NARCIS (Netherlands)

    Sipma, J.; Meulepas, R.J.W.; Stams, A.J.M.; Lettinga, G.; Lens, P.N.L.

    2004-01-01

    The conversion routes of carbon monoxide (CO) at 55°C by full-scale grown anaerobic sludges treating paper mill and distillery wastewater were elucidated. Inhibition experiments with 2-bromoethanesulfonate (BES) and vancomycin showed that CO conversion was performed by a hydrogenogenic population an

  9. Selection and characterization of new absorbents for carbon dioxide capture

    Energy Technology Data Exchange (ETDEWEB)

    Ma' mun, Sholeh

    2005-09-01

    Removal of acidic gases, in particular CO2, is an important industrial operation. Carbon dioxide is produced in large quantities by fossil-fuel-fired power plants, steel production, the production of petrochemicals, cement production, and natural gas purification. The global climate change, where CO2 is found to be a major contributor, is one of the most important and challenging environmental issues facing the world community. This has motivated intensive research on CO2 capture and storage. Carbon dioxide capture by an absorption process is one of the most common industrial technologies today. Recent economic studies indicate that the process will also remain competitive in the future. One of the key improvements under development is new, faster and more energy-efficient absorbents. A chemical to be used as a commercial absorbent must have high net cyclic capacity, high absorption rate for CO2 and good chemical stability. Alkanolamines are the most commonly used chemical absorbents for the removal of acidic gases today. In the first part of this thesis, an experimental screening of new absorbents for CO2 capture was performed by absorption of CO2 into both single absorbents and absorbent mixtures for amine-based and non-amine-based systems at 40 deg. Celsius From testing of approx. 30 systems, it was found that an aqueous 30 mass % AEEA (2-(2-aminoethyl-amino)ethanol) solution seems to be a potentially good absorbent for capturing CO2 from atmospheric flue gases. It offers high absorption rate combined with high absorption capacity. In addition toAEEA, MMEA (2-(methylamino)ethanol) also needs to be considered. It could have a good potential when used in contactors where the two phases are separated, like in membrane contactors, whereas indications from the study showed foaming tendencies that will make it difficult to use in ordinary towers. AEEA as the selected absorbent obtained from the screening tests was further investigated to determine its vapor-liquid

  10. Selection and characterization of new absorbents for carbon dioxide capture

    Energy Technology Data Exchange (ETDEWEB)

    Ma' mun, Sholeh

    2005-09-01

    Removal of acidic gases, in particular CO2, is an important industrial operation. Carbon dioxide is produced in large quantities by fossil-fuel-fired power plants, steel production, the production of petrochemicals, cement production, and natural gas purification. The global climate change, where CO2 is found to be a major contributor, is one of the most important and challenging environmental issues facing the world community. This has motivated intensive research on CO2 capture and storage. Carbon dioxide capture by an absorption process is one of the most common industrial technologies today. Recent economic studies indicate that the process will also remain competitive in the future. One of the key improvements under development is new, faster and more energy-efficient absorbents. A chemical to be used as a commercial absorbent must have high net cyclic capacity, high absorption rate for CO2 and good chemical stability. Alkanolamines are the most commonly used chemical absorbents for the removal of acidic gases today. In the first part of this thesis, an experimental screening of new absorbents for CO2 capture was performed by absorption of CO2 into both single absorbents and absorbent mixtures for amine-based and non-amine-based systems at 40 deg. Celsius From testing of approx. 30 systems, it was found that an aqueous 30 mass % AEEA (2-(2-aminoethyl-amino)ethanol) solution seems to be a potentially good absorbent for capturing CO2 from atmospheric flue gases. It offers high absorption rate combined with high absorption capacity. In addition toAEEA, MMEA (2-(methylamino)ethanol) also needs to be considered. It could have a good potential when used in contactors where the two phases are separated, like in membrane contactors, whereas indications from the study showed foaming tendencies that will make it difficult to use in ordinary towers. AEEA as the selected absorbent obtained from the screening tests was further investigated to determine its vapor-liquid

  11. A THz plasmonics perfect absorber and Fabry-Perot cavity mechanism (Conference Presentation)

    Science.gov (United States)

    Zhou, Jiangfeng; Bhattarai, Khagendra; Silva, Sinhara; Jeon, Jiyeon; Kim, Junoh; Lee, Sang Jun; Ku, Zahyun

    2016-10-01

    The plasmonic metamaterial perfect absorber (MPA) is a recently developed branch of metamaterial which exhibits nearly unity absorption within certain frequency range.[1-6] The optically thin MPA possesses characteristic features of angular-independence, high Q-factor and strong field localization that have inspired a wide range of applications including electromagnetic wave absorption,[3, 7, 8] spatial[6] and spectral[5] modulation of light,[9] selective thermal emission,[9] thermal detecting[10] and refractive index sensing for gas[11] and liquid[12, 13] targets. In this work, we demonstrate a MPA working at terahertz (THz) regime and characterize it using an ultrafast THz time-domain spectroscopy (THz-TDS). Our study reveal an ultra-thin Fabry-Perot cavity mechanism compared to the impedance matching mechanism widely adopted in previous study [1-6]. Our results also shows higher-order resonances when the cavities length increases. These higher order modes exhibits much larger Q-factor that can benefit potential sensing and imaging applications. [1] C. M. Watts, X. L. Liu, and W. J. Padilla, "Metamaterial Electromagnetic Wave Absorbers," Advanced Materials, vol. 24, pp. 98-120, Jun 19 2012. [2] M. Hedayati, F. Faupel, and M. Elbahri, "Review of Plasmonic Nanocomposite Metamaterial Absorber," Materials, vol. 7, pp. 1221-1248, 2014. [3] N. I. Landy, S. Sajuyigbe, J. J. Mock, D. R. Smith, and W. J. Padilla, "Perfect metamaterial absorber," Physical Review Letters, vol. 100, p. 207402, May 23 2008. [4] H. R. Seren, G. R. Keiser, L. Cao, J. Zhang, A. C. Strikwerda, K. Fan, et al., "Optically Modulated Multiband Terahertz Perfect Absorber," Advanced Optical Materials, vol. 2, pp. 1221-1226, 2014. [5] D. Shrekenhamer, J. Montoya, S. Krishna, and W. J. Padilla, "Four-Color Metamaterial Absorber THz Spatial Light Modulator," Advanced Optical Materials, vol. 1, pp. 905-909, 2013. [6] S. Savo, D. Shrekenhamer, and W. J. Padilla, "Liquid Crystal Metamaterial Absorber Spatial

  12. A wormhole-like porous carbon/magnetic particles composite as an efficient broadband electromagnetic wave absorber.

    Science.gov (United States)

    Fang, Jiyong; Liu, Tao; Chen, Zheng; Wang, Yan; Wei, Wei; Yue, Xigui; Jiang, Zhenhua

    2016-04-28

    A method combining liquid-liquid phase separation and the pyrolysis process has been developed to fabricate the wormhole-like porous carbon/magnetic nanoparticles composite with a pore size of about 80 nm (WPC/MNPs-80). In this work, the porous structure was designed to enhance interaction between the electromagnetic (EM) wave and the absorber, while the magnetic nanoparticles were used to bring about magnetic loss ability. The structure, morphology, porosity and magnetic properties of WPC/MNPs-80 were investigated in detail. To evaluate its EM wave attenuation performance, the EM parameters of the absorber and wax composite were measured at 2-18 GHz. WPC/MNPs-80 has an excellent EM wave absorbency with a wide absorption band at a relatively low loading and thin absorber thickness. At the absorber thickness of 1.5 and 2.0 mm, minimum RL values of -29.2 and -47.9 dB were achieved with the RL below -10 dB in 12.8-18 and 9.2-13.3 GHz, respectively. The Co and Fe nanoparticles derived from the chemical reduction of Co0.2Fe2.8O4 can enhance the graphitization process of carbon and thus improve dielectric loss ability. Polarizations in the nanocomposite absorber also play an important role in EM wave absorption. Thus, EM waves can be effectively attenuated by dielectric loss and magnetic loss through multiple reflections and absorption in the porous structure. WPC/MNPs-80 could be an excellent absorber for EM wave attenuation; and the design strategy could be extended as a general method to synthesize other high-performance absorbers.

  13. Exhaled carbon monoxide in asthmatics: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Huang Mao

    2010-04-01

    Full Text Available Abstract Background The non-invasive assessment of airway inflammation is potentially advantageous in asthma management. Exhaled carbon monoxide (eCO measurement is cheap and has been proposed to reflect airway inflammation and oxidative stress but current data are conflicting. The purpose of this meta-analysis is to determine whether eCO is elevated in asthmatics, is regulated by steroid treatment and reflects disease severity and control. Methods A systematic search for English language articles published between 1997 and 2009 was performed using Medline, Embase and Cochrane databases. Observational studies comparing eCO in non-smoking asthmatics and healthy subjects or asthmatics before and after steroid treatment were included. Data were independently extracted by two investigators and analyzed to generate weighted mean differences using either a fixed or random effects meta-analysis depending upon the degree of heterogeneity. Results 18 studies were included in the meta-analysis. The eCO level was significantly higher in asthmatics as compared to healthy subjects and in intermittent asthma as compared to persistent asthma. However, eCO could not distinguish between steroid-treated asthmatics and steroid-free patients nor separate controlled and partly-controlled asthma from uncontrolled asthma in cross-sectional studies. In contrast, eCO was significantly reduced following a course of corticosteroid treatment. Conclusions eCO is elevated in asthmatics but levels only partially reflect disease severity and control. eCO might be a potentially useful non-invasive biomarker of airway inflammation and oxidative stress in nonsmoking asthmatics.

  14. Carbon Monoxide (CO) Is a Novel Inhibitor of Connexin Hemichannels*

    Science.gov (United States)

    León-Paravic, Carmen G.; Figueroa, Vania A.; Guzmán, Diego J.; Valderrama, Carlos F.; Vallejos, Antonio A.; Fiori, Mariana C.; Altenberg, Guillermo A.; Reuss, Luis; Retamal, Mauricio A.

    2014-01-01

    Hemichannels (HCs) are hexamers of connexins that can form gap-junction channels at points of cell contacts or “free HCs” at non-contacting regions. HCs are involved in paracrine and autocrine cell signaling, and under pathological conditions may induce and/or accelerate cell death. Therefore, studies of HC regulation are of great significance. Nitric oxide affects the activity of Cx43 and Cx46 HCs, whereas carbon monoxide (CO), another gaseous transmitter, modulates the activity of several ion channels, but its effect on HCs has not been explored. We studied the effect of CO donors (CORMs) on Cx46 HCs expressed in Xenopus laevis oocytes using two-electrode voltage clamp and on Cx43 and Cx46 expressed in HeLa cells using a dye-uptake technique. CORM-2 inhibited Cx46 HC currents in a concentration-dependent manner. The C-terminal domain and intracellular Cys were not necessary for the inhibition. The effect of CORM-2 was not prevented by guanylyl-cyclase, protein kinase G, or thioredoxin inhibitors, and was not due to endocytosis of HCs. However, the effect of CORM-2 was reversed by reducing agents that act extracellularly. Additionally, CO inhibited dye uptake of HeLa cells expressing Cx43 or Cx46, and MCF-7 cells, which endogenously express Cx43 and Cx46. Because CORM-2 carbonylates Cx46 in vitro and induces conformational changes, a direct effect of that CO on Cx46 is possible. The inhibition of HCs could help to understand some of the biological actions of CO in physiological and pathological conditions. PMID:25384983

  15. Carbon monoxide total column retrievals from TROPOMI shortwave infrared measurements

    Science.gov (United States)

    Landgraf, Jochen; aan de Brugh, Joost; Scheepmaker, Remco; Borsdorff, Tobias; Hu, Haili; Houweling, Sander; Butz, Andre; Aben, Ilse; Hasekamp, Otto

    2016-10-01

    The Tropospheric Monitoring Instrument (TROPOMI) spectrometer is the single payload of the Copernicus Sentinel 5 Precursor (S5P) mission. It measures Earth radiance spectra in the shortwave infrared spectral range around 2.3 µm with a dedicated instrument module. These measurements provide carbon monoxide (CO) total column densities over land, which for clear sky conditions are highly sensitive to the tropospheric boundary layer. For cloudy atmospheres over land and ocean, the column sensitivity changes according to the light path through the atmosphere. In this study, we present the physics-based operational S5P algorithm to infer atmospheric CO columns satisfying the envisaged accuracy ( information on atmospheric scattering. For efficient processing, we deploy a linearized two-stream radiative transfer model as forward model and a profile scaling approach to adjust the CO abundance in the inversion. Based on generic measurement ensembles, including clear sky and cloudy observations, we estimated the CO retrieval precision to be ≤ 11 % for surface albedo ≥ 0.03 and solar zenith angle ≤ 70°. CO biases of ≤ 3 % are introduced by inaccuracies in the methane a priori knowledge. For strongly enhanced CO concentrations in the tropospheric boundary layer and for cloudy conditions, CO errors in the order of 8 % can be introduced by the retrieval of cloud parameters of our algorithm. Moreover, we estimated the effect of a distorted spectral instrument response due to the inhomogeneous illumination of the instrument entrance slit in the flight direction to be < 2 % with pseudo-random characteristics when averaging over space and time. Finally, the CO data exploitation is demonstrated for a TROPOMI orbit of simulated shortwave infrared measurements. Overall, the study demonstrates that for an instrument that performs in compliance with the pre-flight specifications, the CO product will meet the required product performance well.

  16. Carbon monoxide exchange and partitioning of a managed mountain meadow

    Science.gov (United States)

    Hammerle, Albin; Kitz, Florian; Spielmann, Felix; Gerdel, Katharina; Wohlfahrt, Georg

    2016-04-01

    With an average mole fraction of 100 ppb carbon monoxide (CO) plays a critical role in atmospheric chemistry and thus has an indirect global warming potential. While sources/sinks of CO on land at least partially cancel out each other, the magnitude of CO sources and sinks is highly uncertain. Even if direct CO fluxes from/to land ecosystems are very much likely clearly lower in magnitude compared to anthropogenic emissions, biomass burning, emissions from chemical precursors and the OH sink, it may be premature to neglect any direct contributions of land ecosystems to the CO budget. In addition, changes in global climate and resulting changes in global productivity may require re-evaluating older data and assumptions. One major reason for the large uncertainty is a general scarcity of empirical data. An additional factor contributing to the uncertainty is the lack of ecosystem-scale CO exchange measurements, i.e. CO flux data that encompass all sources and sinks within an ecosystem. Here we present data on continuous eddy covariance measurements of CO-fluxes above a managed mountain grassland in combination with soil chamber flux measurements, within- and above-canopy concentration profiles and an inverse Lagrangian analysis to disentangle sinks and sources of CO. Results show the grassland ecosystem to be a net source for CO during daytime, with increasing flux rates at higher solar radiation. At night, if at all, the meadow is a slight sink for CO. The same holds true regarding the soil flux measurements. Additionally, a two-month rainout experiment revealed hardly any differences in CO soil fluxes between rainout- and control-plots unless extremely dry conditions were reached.

  17. Inhibition of cellular respiration by endogenously produced carbon monoxide.

    Science.gov (United States)

    D'Amico, Gabriela; Lam, Francis; Hagen, Thilo; Moncada, Salvador

    2006-06-01

    Endogenously produced nitric oxide (NO) interacts with mitochondrial cytochrome c oxidase, leading to inhibition of cellular respiration. This interaction has been shown to have important physiological and pathophysiological consequences. Exogenous carbon monoxide (CO) is also known to inhibit cytochrome c oxidase in vitro; however, it is not clear whether endogenously produced CO can inhibit cellular respiration and, if so, what the significance of this might be. In this study, we show that exogenous CO inhibits respiration in a moderate but persistent manner in HEK293 cells under ambient (21%) oxygen concentrations (K(i) = 1.44 microM). This effect of CO was increased (K(i) = 0.35 microM) by incubation in hypoxic conditions (1% oxygen). Endogenous CO, generated by HEK293 cells transfected with the inducible isoform of haem oxygenase (haem oxygenase-1; HO-1), also inhibited cellular respiration moderately (by 12%) and this was accompanied by inhibition (23%) of cytochrome c oxidase activity. When the cells were incubated in hypoxic conditions during HO-1 induction, the inhibitory effect of CO on cell respiration was markedly increased to 70%. Furthermore, endogenously produced CO was found to be responsible for the respiratory inhibition that occurs in RAW264.7 cells activated in hypoxic conditions with lipopolysaccharide and interferon-gamma, in the presence of N-(iminoethyl)-L-ornithine to prevent the synthesis of NO. Our results indicate that CO contributes significantly to the respiratory inhibition in activated cells, particularly under hypoxic conditions. Inhibition of cell respiration by endogenous CO through its interaction with cytochrome c oxidase might have an important role in inflammatory and hypoxic conditions.

  18. Magnetic Resonance Imaging Findings in Chronic Carbon Monoxide Intoxication

    Energy Technology Data Exchange (ETDEWEB)

    Durak, A. C.; Coskun, A.; Yikilmaz, A.; Erdogan, F.; Mavili, E.; Guven, M. [Hospital of Erciyes Univ., Kayseri (Turkey). Dept. of Radiology

    2005-05-01

    Purpose: To define the cranial magnetic resonance imaging (MRI) features of the chronic stage of carbon monoxide (CO) poisoning in patients with and without neuropsychiatric sequelae. Material and Methods: Eight patients who had neither symptoms nor neurological sequelae and eight patients with neuropsychiatric sequelae were included in the study. Patients aged between 9 to 57 (mean 32.2 years). All patients had been comatose at initial admittance and awoke after normobaric 100% oxygen therapy within 1-7 days. In this study, the patients were being examined with routine cranial MRI between 1 and 10 years (mean 3.4 years) after exposure to CO. Results: The most common finding was bilateral symmetric hyperintensity of the white matter, which was more significant in the centrum semiovale, with relative sparing of the temporal lobes and anterior parts of the frontal lobes on T2-weighted and FLAIR images in all patients. Cerebral cortical atrophy was seen in 10 patients; mild atrophy of cerebellar hemispheres in 8; and vermian atrophy in 11. Corpus callosum was atrophic in one patient. Bilateral globus pallidus lesions were seen in three patients. The lesions were hypointense on T1-weighted images and hyperintense on T2-weighted and FLAIR images. Conclusion: Patients with severe CO intoxication may develop persistent cerebral changes independently of their neuropsychiatric findings in the chronic stage. They may present with characteristic MRI findings as described here, even if asymptomatic. The history of CO exposure is therefore helpful for recognizing and interpreting the MRI findings of chronic stage CO intoxication.

  19. Carbon monoxide pollution and neurodevelopment: A public health concern.

    Science.gov (United States)

    Levy, Richard J

    2015-01-01

    Although an association between air pollution and adverse systemic health effects has been known for years, the effect of pollutants on neurodevelopment has been underappreciated. Recent evidence suggests a possible link between air pollution and neurocognitive impairment and behavioral disorders in children, however, the exact nature of this relationship remains poorly understood. Infants and children are uniquely vulnerable due to the potential for exposure in both the fetal and postnatal environments during critical periods in development. Carbon monoxide (CO), a common component of indoor and outdoor air pollution, can cross the placenta to gain access to the fetal circulation and the developing brain. Thus, CO is of particular interest as a known neurotoxin and a potential public health threat. Here we review overt CO toxicity and the policies regulating CO exposure, detail the evidence suggesting a potential link between CO-associated ambient air pollution, tobacco smoke, and learning and behavioral abnormalities in children, describe the effects of subclinical CO exposure on the brain during development, and provide mechanistic insight into a potential connection between CO exposure and neurodevelopmental outcome. CO can disrupt a number of critical processes in the developing brain, providing a better understanding of how this specific neurotoxin may impair neurodevelopment. However, further investigation is needed to better define the effects of perinatal CO exposure on the immature brain. Current policies regarding CO standards were established based on evidence of cardiovascular risk in adults with pre-existing comorbidities. Thus, recent and emerging data highlighted in this review regarding CO exposure in the fetus and developing child may be important to consider when the standards and guidelines are evaluated and revised in the future.

  20. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jiajun; Yang, Ming [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Kosterin, Paul [Department of Neuroscience, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Salzberg, Brian M. [Department of Physiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Milovanova, Tatyana N.; Bhopale, Veena M. [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Thom, Stephen R., E-mail: sthom@smail.umaryland.edu [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States)

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1 h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1 h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries. - Highlights: • Circulating microparticles (MPs) increase in mice exposed to 100 ppm CO or more. • MPs are lysed by infusing the surfactant polyethylene glycol telomere B. • CO-induced MPs cause neutrophil activation, vascular leak and CNS dysfunction. • Similar tissue injuries do not arise with MPs obtained from air-exposed, control mice.

  1. Compliance with Washington State's requirement for residential carbon monoxide alarms

    Directory of Open Access Journals (Sweden)

    Neil B. Hampson

    2017-03-01

    Full Text Available Carbon monoxide (CO poisoning is responsible for significant morbidity and mortality in the US. In response, a majority of states have passed legislation in recent years requiring the installation of residential CO alarms. There is, however, no published information evaluating compliance with such laws. Employees of a Seattle medical center were surveyed in 2008 regarding home use of CO and smoke alarms. Washington State enacted legislation requiring residential CO alarms by all residences by January 1, 2013. The survey was repeated in mid-2016 to evaluate compliance. In 2016, a total of 354 employees completed the survey and their responses were compared to an equal number of 2008 survey respondents matched by home ownership and ZIP code. Residential CO alarm use rose from 37% to 78% (p < 0.0001. Among homeowners, 78% had alarms while 80% of renters had them. Homeowners with the highest compliance (96% had purchased their homes since January 1, 2013 while those with the lowest compliance (73% had purchased them earlier. A majority (79% of renters without alarms reported the reason was that their landlord did not provide one, a violation of the law. Only one-half to two-thirds of all equipped homes had the required number of either CO or smoke alarms. Use of residential CO alarms increased significantly in this study population three years after law required them. Areas for further improvement include education of landlords, tenants, and longtime homeowners about the law, as well as public education regarding the number of CO and smoke alarms needed.

  2. Effect of the bio-absorbent on the microwave absorption property of the flaky CIPs/rubber absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yang; Xu, Yonggang, E-mail: xuyonggang221@163.com; Cai, Jun; Yuan, Liming; Zhang, Deyuan

    2015-09-01

    Microwave absorbing composites filled with flaky carbonyl iron particles (CIPs) and the bio-absorbent were prepared by using a two-roll mixer and a vulcanizing machine. The electromagnetic (EM) parameters were measured by a vector network analyzer and the reflection loss (RL) was measured by the arch method in the frequency range of 1–4 GHz. The uniform dispersion of the absorbents was verified by comparing the calculated RL with the measured one. The results confirm that as the bio-absorbent was added, the permittivity was increased due to the volume content of absorbents, and the permeability was enlarged owing to the volume content of CIPs and interactions between the two absorbents. The composite filled with bio-absorbents achieved an excellent absorption property at a thickness of 1 mm (minimum RL reaches −7.8 dB), and as the RL was less than −10 dB the absorption band was widest (2.1–3.8 GHz) at a thickness of 2 mm. Therefore, the bio-absorbent is a promising additive candidate on fabricating microwave absorbing composites with a thinner thickness and wider absorption band. - Graphical abstract: Morphology of composites filled with flaky CIPs and the bio-absorbent. The enhancement of bio-absorbent on the electromagnetic absorption property of composites filled with flaky carbonyl iron particles (CIPs) is attributed to the interaction of the two absorbents. The volume content of the FCMPs with the larger shape CIPs play an important role in this effects, the composites filled with irons and bio-absorbents can achieve wider-band and thinner-thickness absorbing materials. - Highlights: • Absorbers filled with bio-absorbents and CIPs was fabricated. • Bio-absorbents enhanced the permittivity and permeability of the composites. • The absorbent interactions play a key role in the enhancement mechanism. • Bio-absorbents enhanced the composite RL in 1–4 GHz.

  3. Optimization of sound absorbing performance for gradient multi-layer-assembled sintered fibrous absorbers

    Science.gov (United States)

    Zhang, Bo; Zhang, Weiyong; Zhu, Jian

    2012-04-01

    The transfer matrix method, based on plane wave theory, of multi-layer equivalent fluid is employed to evaluate the sound absorbing properties of two-layer-assembled and three-layer-assembled sintered fibrous sheets (generally regarded as a kind of compound absorber or structures). Two objective functions which are more suitable for the optimization of sound absorption properties of multi-layer absorbers within the wider frequency ranges are developed and the optimized results of using two objective functions are also compared with each other. It is found that using the two objective functions, especially the second one, may be more helpful to exert the sound absorbing properties of absorbers at lower frequencies to the best of their abilities. Then the calculation and optimization of sound absorption properties of multi-layer-assembled structures are performed by developing a simulated annealing genetic arithmetic program and using above-mentioned objective functions. Finally, based on the optimization in this work the thoughts of the gradient design over the acoustic parameters- the porosity, the tortuosity, the viscous and thermal characteristic lengths and the thickness of each samples- of porous metals are put forth and thereby some useful design criteria upon the acoustic parameters of each layer of porous fibrous metals are given while applying the multi-layer-assembled compound absorbers in noise control engineering.

  4. A sound absorbing metasurface with coupled resonators

    Science.gov (United States)

    Li, Junfei; Wang, Wenqi; Xie, Yangbo; Popa, Bogdan-Ioan; Cummer, Steven A.

    2016-08-01

    An impedance matched surface is able, in principle, to totally absorb the incident sound and yield no reflection, and this is desired in many acoustic applications. Here we demonstrate a design of impedance matched sound absorbing surface with a simple construction. By coupling different resonators and generating a hybrid resonance mode, we designed and fabricated a metasurface that is impedance-matched to airborne sound at tunable frequencies with subwavelength scale unit cells. With careful design of the coupled resonators, over 99% energy absorption at central frequency of 511 Hz with a 50% absorption bandwidth of 140 Hz is achieved experimentally. The proposed design can be easily fabricated, and is mechanically stable. The proposed metasurface can be used in many sound absorption applications such as loudspeaker design and architectural acoustics.

  5. Absorbing angles, Steiner minimal trees, and antipodality

    CERN Document Server

    Martini, Horst; de Wet, P Oloff; 10.1007/s10957-009-9552-1

    2011-01-01

    We give a new proof that a star $\\{op_i:i=1,...,k\\}$ in a normed plane is a Steiner minimal tree of its vertices $\\{o,p_1,...,p_k\\}$ if and only if all angles formed by the edges at o are absorbing [Swanepoel, Networks \\textbf{36} (2000), 104--113]. The proof is more conceptual and simpler than the original one. We also find a new sufficient condition for higher-dimensional normed spaces to share this characterization. In particular, a star $\\{op_i: i=1,...,k\\}$ in any CL-space is a Steiner minimal tree of its vertices $\\{o,p_1,...,p_k\\}$ if and only if all angles are absorbing, which in turn holds if and only if all distances between the normalizations $\\frac{1}{\\|p_i\\|}p_i$ equal 2. CL-spaces include the mixed $\\ell_1$ and $\\ell_\\infty$ sum of finitely many copies of $R^1$.

  6. Absorbing Software Testing into the Scrum Method

    Science.gov (United States)

    Tuomikoski, Janne; Tervonen, Ilkka

    In this paper we study, how to absorb software testing into the Scrum method. We conducted the research as an action research during the years 2007-2008 with three iterations. The result showed that testing can and even should be absorbed to the Scrum method. The testing team was merged into the Scrum teams. The teams can now deliver better working software in a shorter time, because testing keeps track of the progress of the development. Also the team spirit is higher, because the Scrum team members are committed to the same goal. The biggest change from test manager’s point of view was the organized Product Owner Team. Test manager don’t have testing team anymore, and in the future all the testing tasks have to be assigned through the Product Backlog.

  7. Use of Wedge Absorbers in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Summers, D. [Univ. of Mississippi, Oxford, MS (United States); Mohayai, T. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); IIT, Chicago, IL (United States); Snopok, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); IIT, Chicago, IL (United States); Rogers, C. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL)

    2017-03-01

    Wedge absorbers are needed to obtain longitudinal cooling in ionization cooling. They also can be used to obtain emittance exchanges between longitudinal and transverse phase space. There can be large exchanges in emittance, even with single wedges. In the present note we explore the use of wedge absorbers in the MICE experiment to obtain transverse–longitudinal emittance exchanges within present and future operational conditions. The same wedge can be used to explore “direct” and “reverse” emittance exchange dynamics, where direct indicates a configuration that reduces momentum spread and reverse is a configuration that increases momentum spread. Analytical estimated and ICOOL and G4BeamLine simulations of the exchanges at MICE parameters are presented. Large exchanges can be obtained in both reverse and direct configurations.

  8. Oxygen absorbers in food preservation: a review

    OpenAIRE

    Cichello, Simon Angelo

    2014-01-01

    The preservation of packaged food against oxidative degradation is essential to establish and improve food shelf life, customer acceptability, and increase food security. Oxygen absorbers have an important role in the removal of dissolved oxygen, preserving the colour, texture and aroma of different food products, and importantly inhibition of food spoilage microbes. Active packaging technology in food preservation has improved over decades mostly due to the sealing of foods in oxygen imperme...

  9. 2D Saturable Absorbers for Fibre Lasers

    Directory of Open Access Journals (Sweden)

    Robert I. Woodward

    2015-11-01

    Full Text Available Two-dimensional (2D nanomaterials are an emergent and promising platform for future photonic and optoelectronic applications. Here, we review recent progress demonstrating the application of 2D nanomaterials as versatile, wideband saturable absorbers for Q-switching and mode-locking fibre lasers. We focus specifically on the family of few-layer transition metal dichalcogenides, including MoS2, MoSe2 and WS2.

  10. VUV Absorbing Vapours in n-Perfluorocarbons

    CERN Document Server

    Albrecht, E; Bellunato, T F; Bressan, A; Dalla Torre, S; D'Ambrosio, C; Davenport, M; Dragicevic, M; Duarte-Pinto, S; Fauland, P; Ilie, S; Lenzen, Georg; Pagano, P; Piedigrossi, D; Tessarotto, F; Ullaland, O

    2003-01-01

    The optical transparency of perfluorocarbons used as Cherenkov media is of prime importance to many Ring Imaging Cherenkov detectors. We will in this paper show that the main photon absorbers in these fluids are hydrocarbons with double or triple bonds. We will moreover discuss a process which can eliminate these pollutants and restore the intrinsic excellent optical transparency of these fluids in the VUV range.

  11. Preparation of perlite-based carbon dioxide absorbent.

    Science.gov (United States)

    He, H; Wu, L; Zhu, J; Yu, B

    1994-02-01

    A new highly efficient carbon dioxide absorbent consisting of sodium hydroxide, expanded perlite and acid-base indicator was prepared. The absorption efficiency, absorption capacity, flow resistance and color indication for the absorbent were tested and compared with some commercial products. The absorbent can reduce the carbon dioxide content in gases to 3.3 ppb (v/v) and absorbs not less than 35% of its weight of carbon dioxide. Besides its large capacity and sharp color indication, the absorbent has an outstanding advantage of small flow resistance in comparison with other commercial carbon dioxide absorbents. Applications in gas analysis and purification were also investigated.

  12. Gaseous Hydrocarbon Separations Using Functionalized Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Moura Leila

    2016-03-01

    Full Text Available The functionalization of the side chains on the cation or the anion of an ionic liquid is a common approach to tailor its properties for different processes including the separation of gases. In this paper, we present the current state of the art concerning the usage of ionic liquids for hydrocarbon separations. We also show how the functionalization of ionic liquids or the appropriate anion/cation combinations can contribute to the increase of the performance of the ionic liquids for the separation of gaseous hydrocarbons – either by improving the capacity of the ionic liquid to absorb a given gas or by increasing the selectivity towards a particular hydrocarbon. Original results concerning the usage of olefin-complexing metal salts of lithium (I, nickel (II and copper (II dissolved in ionic liquids for selectively absorbing light olefins are presented. It is observed that the absorption capacity of an imidazolium-based ionic liquid is doubled by the addition of a copper (II salt. This result is compared with the effect of the functionalization of the ionic liquid and the advantages and difficulties of the two approaches are analyzed.

  13. Oxidative Carbonylation of Aromatic Amines with CO Catalyzed by 1,3-Dialkylimidazole-2-selenone in Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Fengshou Tian

    2015-01-01

    Full Text Available 1,3-Dialkylimidazole-2-selenone as a novel substituted selenium heterocyclic catalyst was used to catalyze oxidative carbonylation of aromatic amines with carbon monoxide in the presence of air to symmetrical ureas in up to 97% yield in ionic liquids.

  14. Market Liquidity and Funding Liquidity

    OpenAIRE

    Brunnermeier, Markus K; Lasse Heje Pedersen

    2007-01-01

    We provide a model that links an asset's market liquidity - i.e., the ease with which it is traded - and traders' funding liquidity - i.e., the ease with which they can obtain funding. Traders provide market liquidity, and their ability to do so depends on their availability of funding. Conversely, traders' funding, i.e., their capital and the margins they are charged, depend on the assets' market liquidity. We show that, under certain conditions, margins are destabilizing and market liquidit...

  15. Market Liquidity and Funding Liquidity

    OpenAIRE

    Markus K. Brunnermeier; Lasse Heje Pedersen

    2007-01-01

    We provide a model that links an asset's market liquidity - i.e., the ease with which it is traded - and traders' funding liquidity - i.e., the ease with which they can obtain funding. Traders provide market liquidity, and their ability to do so depends on their availability of funding. Conversely, traders' funding, i.e., their capital and the margins they are charged, depend on the assets' market liquidity. We show that, under certain conditions, margins are destabilizing and market liquidit...

  16. Active chemisorption sites in functionalized ionic liquids for carbon capture.

    Science.gov (United States)

    Cui, Guokai; Wang, Jianji; Zhang, Suojiang

    2016-07-25

    Development of novel technologies for the efficient and reversible capture of CO2 is highly desired. In the last decade, CO2 capture using ionic liquids has attracted intensive attention from both academia and industry, and has been recognized as a very promising technology. Recently, a new approach has been developed for highly efficient capture of CO2 by site-containing ionic liquids through chemical interaction. This perspective review focuses on the recent advances in the chemical absorption of CO2 using site-containing ionic liquids, such as amino-based ionic liquids, azolate ionic liquids, phenolate ionic liquids, dual-functionalized ionic liquids, pyridine-containing ionic liquids and so on. Other site-containing liquid absorbents such as amine-based solutions, switchable solvents, and functionalized ionic liquid-amine blends are also investigated. Strategies have been discussed for how to activate the existent reactive sites and develop novel reactive sites by physical and chemical methods to enhance CO2 absorption capacity and reduce absorption enthalpy. The carbon capture mechanisms of these site-containing liquid absorbents are also presented. Particular attention has been paid to the latest progress in CO2 capture in multiple-site interactions by amino-free anion-functionalized ionic liquids. In the last section, future directions and prospects for carbon capture by site-containing ionic liquids are outlined.

  17. A Fire Department Community Health Intervention to Prevent Carbon Monoxide Poisoning Following a Hurricane

    Science.gov (United States)

    Levy, Matthew; Jenkins, J Lee; Seaman, Kevin

    2014-01-01

    Portable generators are commonly used during electrical service interruptions that occur following large storms such as hurricanes. Nearly all portable generators use carbon based fuels and produce deadly carbon monoxide gas. Despite universal warnings to operate these generators outside only, the improper placement of generators makes these devices the leading cause of engine related carbon monoxide deaths in the United States. The medical literature reports many cases of Carbon Monoxide (CO) toxicity associated with generator use following hurricanes and other weather events. This paper describes how Howard County, Maryland Fire and Rescue (HCFR) Services implemented a public education program that focused on prevention of Carbon Monoxide poisoning from portable generator use in the wake of events where electrical service interruptions occurred or had the potential to occur. A major challenge faced was communication with those members of the population who were almost completely dependent upon electronic and wireless technologies and were without redundancies. HCFR utilized several tactics to overcome this challenge including helicopter based surveillance and the use of geocoded information from the electrical service provider to identify outage areas. Once outage areas were identified, HCFR personnel conducted a door-to-door canvasing of effected communities, assessing for hazards and distributing information flyers about the dangers of generator use. This effort represents one of the first reported examples of a community-based endeavor by a fire department to provide proactive interventions designed to prevent carbon monoxide illness. PMID:24596660

  18. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Science.gov (United States)

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Compact Reconnaissance Imaging Spectrometer Observations of Water Vapor and Carbon Monoxide

    Science.gov (United States)

    Smith, Michael D.; Wolff, Michael J.; Clancy, R. Todd; Murchie, Scott L.

    2009-01-01

    The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) onboard the Mars Reconnaissance Orbiter (MRO) spacecraft began taking observations in September 2006 and has now collected more than a full Martian year of data. Retrievals performed using the near-infrared spectra obtained by CRISM are used to characterize the seasonal and spatial variation of the column abundance of water vapor and the column-averaged mixing ratio of carbon monoxide. CRISM retrievals show nominal behavior in water vapor during northern hemisphere spring and summer with maximum abundance reaching 50 precipitable micrometers. Water vapor abundance during the southern hemisphere spring and summer appears significantly reduced compared to observations by other instruments taken during previous years. The CRISM retrievals show the seasonally and globally averaged carbon monoxide mixing ratio to be 700 ppm, but with strong seasonal variations at high latitudes. The summertime near-polar carbon monoxide mixing ratio falls to 200 ppm in the south and 400 ppm in the north as carbon dioxide sublimates from the seasonal polar ice caps and dilutes noncondensable species including carbon monoxide. At low latitudes, the carbon monoxide mixing ratio varies in response to the mean seasonal cycle of surface pressure.

  20. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Science.gov (United States)

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  1. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Namik Ozcan

    Full Text Available Abstract Background and objectives: Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. Case 1: After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. Case 2: In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. Conclusion: White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning.

  2. The Effect of Carbon Monoxide Poisoning on Platelet Volume in Children

    Directory of Open Access Journals (Sweden)

    Halise Akça

    2017-04-01

    Full Text Available Introduction: Carbon monoxide poisoning is one of the most important causes of morbidity and mortality. There is increasing evidence supporting the important role of mean platelet volume (MPV as a marker of hypoxia and inflammation. In this study, we aimed to determine changes in MPV values in pediatric patients with carbon monoxide poisoning. Methods: We retrospectively evaluated children who were diagnosed with carbon monoxide poisoning in our hospital between January 2005 and 2014. Results: We included 228 children with carbon monoxide poisoning (49% male in this retrospective, controlled study. The mean age of the patients was 88±56 months. Control group consisted of 200 age-matched healthy children. There was no statistically significant difference in MPV levels between the study and control groups (8.43±1.1 fL and 8.26±0.7 fL, respectively. No correlation of MPV and platelet count with carboxyhemoglobin (COHb was found. Conclusion: In our study, it was determined that MPV value was not a helpful parameter for predicting the diagnosis of acute carbon monoxide poisoning in childhood. The difference between the MPV values and the lack of significance and the absence of correlation between MPV value and COHb level led to the fact that MPV was not a guide indicating the clinical severity of the condition.

  3. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Apte, M.G.

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10{degrees}C to 30{degrees}C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  4. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G. [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  5. Critical experiments on an enriched uranium solution system containing periodically distributed strong thermal neutron absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Rothe, R.E.

    1996-09-30

    A series of 62 critical and critical approach experiments were performed to evaluate a possible novel means of storing large volumes of fissile solution in a critically safe configuration. This study is intended to increase safety and economy through use of such a system in commercial plants which handle fissionable materials in liquid form. The fissile solution`s concentration may equal or slightly exceed the minimum-critical-volume concentration; and experiments were performed for high-enriched uranium solution. Results should be generally applicable in a wide variety of plant situations. The method is called the `Poisoned Tube Tank` because strong neutron absorbers (neutron poisons) are placed inside periodically spaced stainless steel tubes which separate absorber material from solution, keeping the former free of contamination. Eight absorbers are investigated. Both square and triangular pitched lattice patterns are studied. Ancillary topics which closely model typical plant situations are also reported. They include the effect of removing small bundles of absorbers as might occur during inspections in a production plant. Not taking the tank out of service for these inspections would be an economic advantage. Another ancillary topic studies the effect of the presence of a significant volume of unpoisoned solution close to the Poisoned Tube Tank on the critical height. A summary of the experimental findings is that boron compounds were excellent absorbers, as expected. This was true for granular materials such as Gerstley Borate and Borax; but it was also true for the flexible solid composed of boron carbide and rubber, even though only thin sheets were used. Experiments with small bundles of absorbers intentionally removed reveal that quite reasonable tanks could be constructed that would allow a few tubes at a time to be removed from the tank for inspection without removing the tank from production service.

  6. Slow and Fast Light in an Electro-Absorber

    DEFF Research Database (Denmark)

    Öhman, Filip; Bermejo Ramirez, Andres; Sales, Salvador

    2006-01-01

    We demonstrate controllable and large time delay in cascaded semiconductor saturable absorbers and amplifiers. The possibility of further increasing the tuneable phase shift by utilizing field screening effects in the quantum well absorber is demonstrated....

  7. Modeling the Effect of Polychromatic Light in Quantitative Absorbance Spectroscopy

    Science.gov (United States)

    Smith, Rachel; Cantrell, Kevin

    2007-01-01

    Laboratory experiment is conducted to give the students practical experience with the principles of electronic absorbance spectroscopy. This straightforward approach creates a powerful tool for exploring many of the aspects of quantitative absorbance spectroscopy.

  8. Neurological Effects of Acute Carbon Monoxide Poisoning in Children

    Directory of Open Access Journals (Sweden)

    Coskun YARAR

    2009-11-01

    Full Text Available Carbon monoxide poisoning (COP is one of the most common causes of mortality and morbidity due to poisoning in all over the world. Although the incidence of COP has not been known exactly in the childhood, almost one-third of CO exposures occurred in children. The data regarding COP in children are inconclusive. Children may be more vulnerable to CO exposure than adults as a result of their high respiration and metabolic rates, high oxygen metabolism, and immature central nervous system. Recent researches proposed new theories about neurological effects of CO toxicity. The clinical presentations associated acute COP may be various and nonspecific. Unrecognized CO exposure may lead to significant morbidity and mortality. CO exposed children often become symptomatic earlier, and recover more rapidly, than similarly CO exposed adults. Mild clinical signs and symptoms associated with COP are headache, dizziness, weakness, lethargy, and myalgia; however, severe signs and symptoms such as blurred vision, syncope, convulsion, coma, cardiopulmonary arrest and death can also accompany with COP. Neurologic manifestations can include altered mental status at different degrees, neck stiffness, tremor, ataxia, and positive Babinski's sign. Delayed neurologic sequels (DNS of COP might be seen in children like adults. DNS symptoms and signs in children include memory problems, mental retardation, mutism, fecal and urinary incontinence, motor deficits, facial palsy, psychosis, chronic headache, seizures, and epilepsy. After CO exposure children must be cared to detect and treat DNS. Although hyperbaric oxygen therapy (HBOT is reported to prevent development of DNS, its indications, application duration and procedures are controversial in both of the children and adults. Although their predictive values are limited, exposing to CO more than eight hours and suffering from CO-induced coma, cardiac arrest, lactic acidosis, high COHb levels, and pathologic findings

  9. Carbon Monoxide Promotes Lateral Root Formation in Rapeseed

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Carbon monoxide (CO), an odorless, tasteless and colorless gas, has recently proved to be an important bioactive or signal molecule in mammalian cells, with its effects mediated mainly by nitric oxide (NO). In the present report, we show that exogenous CO induces lateral root (LR) formation, an NO-dependent process. Administration of the CO donor hematin to rapeseed (Brassica napus L. Yangyou 6) seedlings for 3 days, dose-dependently promoted the total length and number of LRs. These responses were also seen following the application of gaseous CO aqueous solutions of different saturated concentrations. Furthermore, the actions of CO on seedlings were fully reversed when the CO scavenger hemoglobin (Hb)or the CO-specific synthetic inhibitor zinc protoporphyrin-Ⅸ (ZnPPIX) were added. Interestingly, depletion of endogenous NO using its specific scavenger 2-(4-carboxyphenyl)-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide potassium salt (cPTIO)or the nitric oxide synthase (NOS) inhibitor NG-nitro-L-arginine methyl ester (L-NAME), led to the complete abolition of LR development, illustrating an important role for endogenous NO in the action of CO on LR formation. However, the or absence of ZnPPIX. Furthermore, using an anatomical approach combined with laser scanning confocal microscopy with the NO-specific fluorophore 4,5-diaminofluorescein diacetate, we observed that both hematin and SNP increased NO release compared with control samples and that the NO signal was mainly distributed in the LR primordia (LRP), especially after 36 h treatment. The LRP were found to have similar morphology in control, SNP- and hematin-treated seedlings.Similarly, the enhancement of the NO signal by CO at 36 h was differentially quenched by the addition of cPTIO, L-NAME,ZnPPIX and Hb. In contrast, the induction of NO caused by SNP was not affected by the application of ZnPPIX. Therefore,we further deduced that CO induces LR formation probably mediated by the NO/NOS pathway and NO may act

  10. Snowmelt onset hinders bromine monoxide heterogeneous recycling in the Arctic

    Science.gov (United States)

    Burd, Justine A.; Peterson, Peter K.; Nghiem, Son V.; Perovich, Don K.; Simpson, William R.

    2017-08-01

    Reactive bromine radicals (bromine atoms, Br, and bromine monoxide, BrO) deplete ozone and alter tropospheric oxidation chemistry during the Arctic springtime (February-June). As spring transitions to summer (May-June) and snow begins to melt, reactive bromine events cease and BrO becomes low in summer. In this study, we explore the relationship between the end of the reactive bromine season and snowmelt timing. BrO was measured by Multi-AXis Differential Optical Absorption Spectrometer at Utqiaġvik (Barrow), AK, from 2012 to 2016 and on drifting buoys deployed in Arctic sea ice from 2011 to 2016, a total of 13 site and year combinations. The BrO seasonal end date (SED) was objectively determined and was compared to surface-air-temperature-derived melt onset date (MOD). The SED was highly correlated with the MOD (N = 13, R2 = 0.983, RMS = 1.9 days), and BrO is only observed at subfreezing temperatures. In subsets of these sites and years where ancillary data were available, we observed that snowpack depth reduced and rain precipitation occurred within a few days of the SED. These data are consistent with snowpack melting hindering BrO recycling, which is necessary to maintain enhanced BrO concentrations. With a projected warmer Arctic, a shift to earlier snowmelt seasons could alter the timing and role of halogen chemical reactions in the Arctic with impacts on ozone depletion and mercury deposition.Plain Language SummaryReactive bromine events in the Arctic are common in spring and deplete ozone and cause mercury deposition. These events are affected by snow and ice, which are changing in the Arctic; therefore, we need to understand how environmental conditions affect reactive bromine chemistry. We find that the reactive bromine season ends when snowpack begins to melt. Through these full seasonal observations, we find that reactive bromine events occur to warmer temperatures than previously reported, with 0°C being the observed threshold above which reactive

  11. Determination of a Jet Fuel Metal Deactivator by High Performance Liquid Chromatography

    Science.gov (United States)

    1983-06-01

    HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Paul C. Hayes, Jr. Fuels Branch...SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on reverse side if necessary and identify by block number) High Performance Liquid Chromatography absorbance...SYMBOL HPLC High Performance Liquid Chromatography P-4 jet propulsion fuel, wide-boiling range, conforming to MIL-T-5624L MDA metal deactivator,

  12. Multimodality evoked potentials in patients with delayed encephalopathy after acute carbon monoxide poisoning

    Institute of Scientific and Technical Information of China (English)

    Xiahong Wang; Bo Xiao; Renjun Gu; Lan Xiao; Yi Yang; Yinhui Hao; Nini Wang; Junlin Mu; Jinggang Yin

    2006-01-01

    Objective: To evaluate the diagnostic and prognostic values in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: The tibial nerve somatosensory evoked potentials (SEPs), vision evoked potentials (VEPs), and brain stem audition evoked potentials(BAEPs) were performed in 32 healthy adults and 43 patients with delayed encephalopathy after acute carbon monoxide poisoning. Results: This paper indicated abnormalities of tibial nerve SEPs in 31 patients (31/43, 72.1%), VEPs in 17 patients (17/28, 60.7%), and BAEPs in 14 patients (14/43, 32.6%). These results showed that the greatest diagnostic value was SEPs, followed by VEPs and, BAEPs with the lowest sensitivity. Conclusion: Multimodality evoked potentials (EPs) can be used for evaluating the diagnostic and prognostic values in cases of delayed encephalopathy after acute carbon monoxide poisoning.

  13. Effect of carbon monoxide inhibition on the growth of an aquatic streptomycete

    Energy Technology Data Exchange (ETDEWEB)

    Francisco, D.E.; Silvey, J.K.G.

    1971-01-01

    A recent investigation has shown that the primary mycelium of aquatic streptomycetes is facultatively aerobic while the secondary mycelium is obligately aerobic. The nature of the differences in aerobic metabolism of various morphological phases in the life history was determined by carbon monoxide inhibition. A slide culture chamber technique which allowed continuous microscopic observation of the growing organism while in various gas environments was used. Two distinct patterns of inhibition were observed. The development of early stages of the life history was inhibited by carbon monoxide in the light and the dark. The site of this inhibition could not be determined. The later stages were inhibited only by carbon monoxide in the dark. This suggested a dependence of the secondary mycelium on the activity of cytochrome oxidase. Thus, the primary and secondary mycelial stages were found to be physiologically distinct.

  14. St. Mary's Villa carbon monoxide accumulation incident review

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-05-15

    On December 26th 2010, carbon monoxide accumulation within St. Mary's Villa led to the deaths of 3 residents. This extended care facility, located in Humboldt, Saskatchewan, was constructed in 1962 and periodic additions to the building were made up to 1990. The Saskatoon Health Region, which operates the facility, hired March Consulting Associates Inc. to perform a review of the investigation reports of the incident. This review demonstrated that during the night of December 25th to December 26th, 2010, several factors, including large gaps in the make-up air unit and extreme wind, led to backdraft conditions in a boiler of the dust wing mechanical room. Exhaust gases, including carbon monoxide, then built up in the room and were blown into the dust wing by the supply air fan. The report indicates the accumulation of carbon monoxide was not caused by one factor but several.

  15. Substantially isotactic, linear, alternating copolymers of carbon monoxide and an olefin

    Science.gov (United States)

    Sen, Ayusman; Jiang, Zhaozhong

    1996-01-01

    The compound, [Pd(Me-DUPHOS)(MeCN).sub.2 ](BF.sub.4).sub.2, [Me-DUPHOS: 1,2-bis(2,5-dimethylphospholano)benzene] is an effective catalyst for the highly enantioselective, alternating copolymerization of olefins, such as aliphatic .alpha.-olefins, with carbon monoxide to form optically active, isotactic polymers which can serve as excellent starting materials for the synthesis of other classes of chiral polymers. For example, the complete reduction of a propylene-carbon monoxide copolymer resulted in the formation of a novel, optically active poly(1,4-alcohol). Also, the previously described catalyst is a catalyst for the novel alternating isomerization cooligomerization of 2-butene with carbon monoxide to form optically active, isotactic poly(1,5-ketone)

  16. Carbon Dioxide in Exoplanetary Atmospheres: Rarely Dominant Compared to Carbon Monoxide and Water

    CERN Document Server

    Heng, Kevin

    2015-01-01

    We present a comprehensive study of the abundance of carbon dioxide in exoplanetary atmospheres. We construct analytical models of systems in chemical equilibrium that include carbon monoxide, carbon dioxide, water, methane and acetylene and relate the equilibrium constants of the chemical reactions to temperature and pressure via the tabulated Gibbs free energies. We prove that such chemical systems may be described by a quintic equation for the mixing ratio of methane. By examining the abundances of these molecules across a broad range of temperatures (spanning equilibrium temperatures from 600 to 2500 K), pressures (via temperature-pressure profiles that explore albedo and opacity variations) and carbon-to-oxygen ratios (from 0.1 to 100), we conclude that carbon dioxide is subdominant compared to carbon monoxide and water. Atmospheric mixing does not alter this conclusion if carbon dioxide is subdominant everywhere in the atmosphere. Carbon dioxide and carbon monoxide may attain comparable abundances if th...

  17. A numerical evaluation of prediction accuracy of CO2 absorber model for various reaction rate coefficients

    Directory of Open Access Journals (Sweden)

    Shim S.M.

    2012-01-01

    Full Text Available The performance of the CO2 absorber column using mono-ethanolamine (MEA solution as chemical solvent are predicted by a One-Dimensional (1-D rate based model in the present study. 1-D Mass and heat balance equations of vapor and liquid phase are coupled with interfacial mass transfer model and vapor-liquid equilibrium model. The two-film theory is used to estimate the mass transfer between the vapor and liquid film. Chemical reactions in MEA-CO2-H2O system are considered to predict the equilibrium pressure of CO2 in the MEA solution. The mathematical and reaction kinetics models used in this work are calculated by using in-house code. The numerical results are validated in the comparison of simulation results with experimental and simulation data given in the literature. The performance of CO2 absorber column is evaluated by the 1-D rate based model using various reaction rate coefficients suggested by various researchers. When the rate of liquid to gas mass flow rate is about 8.3, 6.6, 4.5 and 3.1, the error of CO2 loading and the CO2 removal efficiency using the reaction rate coefficients of Aboudheir et al. is within about 4.9 % and 5.2 %, respectively. Therefore, the reaction rate coefficient suggested by Aboudheir et al. among the various reaction rate coefficients used in this study is appropriate to predict the performance of CO2 absorber column using MEA solution. [Acknowledgement. This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF, funded by the Ministry of Education, Science and Technology (2011-0017220].

  18. Effect of inclusions' distribution on microwave absorbing properties of composites

    Science.gov (United States)

    Qin, Siliang; Wang, Qingguo; Qu, Zhaoming

    2013-03-01

    Effect of inclusions' spatial distributions on the permeability and permittivity of composites is studied using the generalized Maxwell-Garnett equations. The result indicates that inclusions' orientation distribution can increase the longitudinal electromagnetic parameters. For inclusions' random and orientation distribution, single and three-layer absorbers are designed and optimized using genetic algorithm. The result shows that under a given absorbing requirement, absorber with inclusions' orientation distribution is lighter and thinner than absorber with inclusions' random distribution.

  19. Slow and Fast Light in an Electro-Absorber

    DEFF Research Database (Denmark)

    Öhman, Filip; Bermejo Ramirez, Andres; Sales, Salvador

    2006-01-01

    We demonstrate controllable and large time delay in cascaded semiconductor saturable absorbers and amplifiers. The possibility of further increasing the tuneable phase shift by utilizing field screening effects in the quantum well absorber is demonstrated.......We demonstrate controllable and large time delay in cascaded semiconductor saturable absorbers and amplifiers. The possibility of further increasing the tuneable phase shift by utilizing field screening effects in the quantum well absorber is demonstrated....

  20. Method for absorbing an ion from a fluid

    Science.gov (United States)

    Gao, Huizhen; Wang, Yifeng; Bryan, Charles R.

    2007-07-03

    A method for absorbing an ion from a fluid by using dispersing an organic acid into an anion surfactant solution, mixing in a divalent-metal containing compound and a trivalent-metal containing compound and calcining the resulting solid layered double hydroxide product to form an absorbent material and then contacting the absorbent material with an aqueous solution of cations or anions to be absorbed.

  1. Multiple headspace extraction for gas detection in ionic liquids.

    Science.gov (United States)

    Müller, D; Fühl, M; Pinkwart, K; Baltes, N

    2014-10-16

    In this study multiple headspace extraction was used for the first time to measure the saturation concentration of carbon monoxide and oxygen in various ionic liquids (ILs). Many processes in ILs involve the reaction of gases so that the reactant solubility is not a mere characteristical parameter, but understanding the solubility of gases in ILs is required for assessing the feasibility of possible applications. Multiple headspace extraction has proofed to be a powerful tool to obtain solubilities in good accordance with literature data. The measured saturation concentration for carbon monoxide and oxygen in ILs based on rarely researched tetracyanoborates and other anions was in the range of 1.5-6.5mmol/L. The great advantage of multiple headspace extraction is that it is a nonexpensive method that can be realised in most analytical laboratories by combination of a simple gas chromatograph and an eligible headspace injector.

  2. An overview of the development, testing, and application of composite absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Sebesta, F. [Czech Technical Univ., Brehova (Czech Republic); John, J. [Los Alamos National Lab., NM (United States)

    1995-02-01

    Although inorganic exchangers offer many advantages for removing selected elements from radioactive waste streams, few of these materials are suitable for use in packed-bed columns. We review various adaptations of inorganic exchangers for use in columns, which include granular forms of the intrinsic absorbers, absorber compounds supported on other materials, and composite absorbers that use organic or inorganic binders. An organic binding polymer of polyacrylonitrile (PAN), developed at the Czech Technical University, has been demonstrated to offer advantages. We describe general methods for preparing inorganic exchange materials, which then are incorporated into PAN-based composites. Such PAN composites have been used to remove selected radionuclides from a variety of liquid waste streams. Sixteen different PAN composites were prepared for testing at Los Alamos National Laboratory (LANL) as part of an evaluation of potential partitioning agents for remediating the liquid waste in underground storage tanks at the Hanford site near Richland, Washington. Our collaboration with LANL is expected to continue for another 2 years.

  3. A MICROGAP SURGE ABSORBER FABRICATED USING CONVENTIONAL SEMICONDUCTOR TECHNOLOGY

    Institute of Scientific and Technical Information of China (English)

    李宏; 阮航宇

    2001-01-01

    A new type microgap surge absorber fabricated by only semiconductor technique has in it a special structure silicon chip which forms microgaps for gas discharge with electrodes, and has advantages such as small size, low cost, suitability for mass production besides the desirable characteristics that common microgap surge absorbers have. Applications of this absorber in communication facilities are discussed.

  4. 21 CFR 886.3300 - Absorbable implant (scleral buckling method).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable implant (scleral buckling method). 886... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3300 Absorbable implant (scleral buckling method). (a) Identification. An absorbable implant (scleral buckling method) is a...

  5. Graphene metamaterials based tunable terahertz absorber: effective surface conductivity approach

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Lavrinenko, Andrei

    2013-01-01

    In this paper we present the efficient design of functional thin-film metamaterial devices with the effective surface conductivity approach. As an example, we demonstrate a graphene based perfect absorber. After formulating the requirements to the perfect absorber in terms of surface conductivity...... we investigate the properties of graphene wire medium and graphene fishnet metamaterials and demonstrate both narrowband and broadband tunable absorbers....

  6. About sound mufflers sound-absorbing panels aircraft engine

    Science.gov (United States)

    Dudarev, A. S.; Bulbovich, R. V.; Svirshchev, V. I.

    2016-10-01

    The article provides a formula for calculating the frequency of sound absorbed panel with a perforated wall. And although the sound absorbing structure is a set of resonators Helmholtz, not individual resonators should be considered in acoustic calculations, and all the perforated wall panel. The analysis, showing how the parameters affect the size and sound-absorbing structures in the absorption rate.

  7. Graphene metamaterials based tunable terahertz absorber: effective surface conductivity approach.

    Science.gov (United States)

    Andryieuski, Andrei; Lavrinenko, Andrei V

    2013-04-08

    In this paper we present the efficient design of functional thin-film metamaterial devices with the effective surface conductivity approach. As an example, we demonstrate a graphene based perfect absorber. After formulating the requirements to the perfect absorber in terms of surface conductivity we investigate the properties of graphene wire medium and graphene fishnet metamaterials and demonstrate both narrowband and broadband tunable absorbers.

  8. Adaptive Seat Energy Absorbers for Enhanced Crash Safety: Technology Demonstration

    Science.gov (United States)

    2016-08-01

    ARL-TR-7743 ● AUG 2016 US Army Research Laboratory Adaptive Seat Energy Absorbers for Enhanced Crash Safety: Technology...AUG 2016 US Army Research Laboratory Adaptive Seat Energy Absorbers for Enhanced Crash Safety: Technology Demonstration by Muthuvel...COVERED (From - To) 10 January 2012–29 February 2016 4. TITLE AND SUBTITLE Adaptive Seat Energy Absorbers for Enhanced Crash Safety: Technology

  9. 21 CFR 868.5300 - Carbon dioxide absorbent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon dioxide absorbent. 868.5300 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5300 Carbon dioxide absorbent. (a) Identification. A carbon dioxide absorbent is a device intended for medical purposes that consists of...

  10. 21 CFR 868.5310 - Carbon dioxide absorber.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carbon dioxide absorber. 868.5310 Section 868.5310...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5310 Carbon dioxide absorber. (a) Identification. A carbon dioxide absorber is a device that is intended for medical purposes and that is used in...

  11. 卷烟烟气中一氧化碳的简易测试方法%A simple method for carbon monoxide testing in the cigarette smoke

    Institute of Scientific and Technical Information of China (English)

    王兆东; 胡秀峰; 霍晓晖; 王玉林; 李占臣; 韦丽红; 康晓鸥; 崔立娟

    2013-01-01

    为了降低烟气中CO吸附材料的筛选成本,组装了一套烟气采集装置,该装置能够直接采集点燃卷烟的烟气,也能采集经过吸附材料后的烟气.对所采集烟气的CO体积分数进行检测,考察吸附材料或添加剂吸附CO的效果.结果表明,该装置适宜的采样时间为烟支燃烧后3~5 min,所需吸附材料仅约1 g,所需测试时间为50 min,具有组装容易、操作简单和价格低廉的特点.但因为采集烟气的针孔有泄露,再加上手工操作导致不确定性,该方法仅适用于定性筛选吸附材料或添加剂.%This article is aimed to present an easy and practical method for testing carbon monoxide in the cigarette smoke.First of all,we have collected the cigarette smoke sample by using a smoke sample assembling device.The sample can be collected directly by lighting a cigarette in the device in a time length of about 3-5 min after the cigarette was lit up.Then,we can study the CO-adsorbed features of the adsorbed material by comparing the results of carbon monoxide testing in the smoke sample.A test can thus be finished with the adsorbing material 1 g or so in 50 minutes at a time.The method we have worked out is characterized by its easy assembling,low price and simple operation.The application results of the experiment with the method demonstrate that it can improve the smoke sample preparation and processing line of the absorbing material or addifives greatly due to producing less reaction products.The advantages of the method also lie in its screening of the absorbing materials or additives qualitatively,for the smoke leakage occurred just through a small pinhole when the sample is collected by using a syringe and for the particular uncertainty manually.In order to reduce the cost of research and development to screen adsorption material for adsorbing the carbon monoxide,the method we have worked out is simple in application,convenient in collecting the testing sample and testing

  12. Absorption and oxidation of nitrogen oxide in ionic liquids

    DEFF Research Database (Denmark)

    Kunov-Kruse, Andreas Jonas; Thomassen, Peter Langelund; Riisager, Anders

    2016-01-01

    . The nitric acid is absorbed in the ionic liquid up to approximately one mole HNO3 per mole of the ionic liquid due to the formation of hydrogen bonds. The nitric acid can be desorbed by heating, thereby regenerating the ionic liquid with excellent reproducibility. Here, time-resolved in-situ spectroscopic......A new strategy for capturing nitrogen oxide, NO, from the gas phase is presented. Dilute NO gas is removed from the gas phase by ionic liquids under ambient conditions. The nitrate anion of the ionic liquid catalyzes the oxidation of NO to nitric acid by atmospheric oxygen in the presence of water...

  13. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  14. Distributions of 14 elements on 60 selected absorbers from two simulant solutions (acid-dissolved sludge and alkaline supernate) for Hanford HLW Tank 102-SY

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, S.F.; Svitra, Z.V.; Bowen, S.M.

    1993-10-01

    Sixty commercially available or experimental absorber materials were evaluated for partitioning high-level radioactive waste. These absorbers included cation and anion exchange resins, inorganic exchangers, composite absorbers, and a series of liquid extractants sorbed on porous support-beads. The distributions of 14 elements onto each absorber were measured from simulated solutions that represent acid-dissolved sludge and alkaline supernate solutions from Hanford high-level waste (HLW) Tank 102-SY. The selected elements, which represent fission products (Ce, Cs, Sr, Tc, and Y); actinides (U, Pu, and Am); and matrix elements (Cr, Co, Fe, Mn, Zn, and Zr), were traced by radionuclides and assayed by gamma spectrometry. Distribution coefficients for each of the 1680 element/absorber/solution combinations were measured for dynamic contact periods of 30 min, 2 h, and 6 h to provide sorption kinetics information for the specified elements from these complex media. More than 5000 measured distribution coefficients are tabulated.

  15. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  16. Analysis of an air cooled ammonia-water vertical tubular absorber

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Seara, J.; Uhia, F.J.; Sieres, J. [Area de Maquinas y Motores Termicos, Escuela Tecnica Superior de Ingenieros Industriales, Campus Lagoas-Marcosende, No 9, 36310 Vigo (Spain)

    2007-03-15

    This paper presents a detailed analysis of an ammonia-water vertical tubular absorber cooled by air. The absorption process takes place co-currently upward inside the tubes. The tubes are externally finned with continuous plate fins and the tube rows are arranged staggered in the direction of the air flow. The air is forced over the tube bank and circulates between the plain fins in cross flow with the ammonia-water mixture. The analysis has been carried out by means of a mathematical model developed on the basis of mass and energy balances and heat and mass transfer equations. The model takes into account separately the churn, slug and bubbly flow patterns experimentally forecasted in this type of absorption processes inside vertical tubes and considers the simultaneous heat and mass transfer processes in both liquid and vapour phases, as well as heat transfer to the cooling air. The model has been implemented in a computer program. Results based on a representative design and nominal operating conditions of an absorber for a small capacity ammonia-water absorption refrigeration system are shown. A parametric analysis was realised to investigate the influence of the design parameters and operating conditions on the absorber performance. The noteworthy results that have effect on practical design of the absorber are presented and commented. (authors)

  17. [Performance of desulfurizing absorbent of roasted navajoite].

    Science.gov (United States)

    Chen, Fang; Yang, Chun-ping; Gan, Hai-ming; Wu, Ting; Chen, Hai-lin; Chen, Hong; Xu, Ke-hui; Xie, Geng-xin

    2010-04-01

    An innovative flue gas desulfurization (FGD) coupling process was proposed in this study to overcome the problems in wet-type limestone/lime processes which include fouling, clogging, and difficulty of selling the by-products and the problems in traditional process for vanadium extraction from navajoite ore such as excessive consumption of sulfuric acid and emissions of pollutants. The performance of a jet bubbling reactor (JBR) at pilot-scale was evaluated using navajoite ore produced in the process of extracting vanadium pentoxide as desulfurization absorbent. Results showed that navajoite ore slurry achieved better desulfurization performance than limestone slurry. When the inlet flue gas pressure drop was 3.0 kPa, the gas flow was about 2350 m3 x h(-1) and the pH of the navajoite ore slurry was higher than 4.5, the desulfurization efficiency was stable about 90%. The SO2 removal efficiency appeared to increase along with the increasing of absorbent cycle-index. The efficiency of the second circulation was improved 3.5% compared to the first circulation. After an operating duration of 40 minutes, the leaching rate of vanadium pentoxide was about 20%, and reached 60% when the by-products were leached with 5% dilute sulfuric acid for 10 hours. The by-product from this process not only could be used to produce vanadium pentoxide which is a valuable industrial product, but also could significantly overcome the pollution problem existing in the traditional refining process of vanadium pentoxide when navajoite ore is used as the feed material. This FGD process using roasted navajoite slurry as absorbent is environmental sound and cost-effective, and shows the potential for application in the field of flue gas desulfurization as well as hydrometallurgy.

  18. Cyclic process for producing methane from carbon monoxide with heat removal

    Science.gov (United States)

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  19. Ab initio molecular dynamics simulation study of successive hydrogenation reactions of carbon monoxide producing methanol

    Science.gov (United States)

    Pham, Thi Nu; Ono, Shota; Ohno, Kaoru

    2016-04-01

    Doing ab initio molecular dynamics simulations, we demonstrate a possibility of hydrogenation of carbon monoxide producing methanol step by step. At first, the hydrogen atom reacts with the carbon monoxide molecule at the excited state forming the formyl radical. Formaldehyde was formed after adding one more hydrogen atom to the system. Finally, absorption of two hydrogen atoms to formaldehyde produces methanol molecule. This study is performed by using the all-electron mixed basis approach based on the time dependent density functional theory within the adiabatic local density approximation for an electronic ground-state configuration and the one-shot GW approximation for an electronic excited state configuration.

  20. [Effect of lead and carbon monoxide under the condition of diabetic metabolism (author's transl)].

    Science.gov (United States)

    Schlipköter, H W; Klitzke, M; Unnewehr, J

    1979-06-01

    The NZO-Mice were used to study the influence of carbon monoxide and lead under the condition of diabetic metabolism. The animals treated with 80 ppm (COHb 10.81) showed significantly lower tolerance for glucose. Even after removing the burden of carbon monoxide for 50 days, the blood sugar level after glucose tolerance test remained in experimental animals significantly higher than in controls (20-min-value). The NZO-Mice after enteral lead exposition showed no significant changes of the condition of the diabetic metabolism after the glucose tolerance test. However, the NZO-Mice, compared to NMRI mice and rats, reached significantly higher level of blood sugar.

  1. Toward Carbon Monoxide-Based Therapeutics: Critical Drug Delivery and Developability Issues.

    Science.gov (United States)

    Ji, Xingyue; Damera, Krishna; Zheng, Yueqin; Yu, Bingchen; Otterbein, Leo E; Wang, Binghe

    2016-02-01

    Carbon monoxide (CO) is an intrinsic signaling molecule with importance on par with that of nitric oxide. During the past decade, pharmacologic studies have amply demonstrated the therapeutic potential of carbon monoxide. However, such studies were mostly based on CO inhalation and metal-based CO-releasing molecules. The field is now at the stage that a major effort is needed to develop pharmaceutically acceptable forms of CO for delivery via various routes such as oral, injection, infusion, or topical applications. This review examines the state of the art, discusses the existing hurdles to overcome, and proposes developmental strategies necessary to address remaining drug delivery issues.

  2. Range Measurements of keV Hydrogen Ions in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Andersen, H.H.

    1984-01-01

    Ranges of 1.3–3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen....... The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees...

  3. Carbon Monoxide Poisoning during Pregnancy: Presentation of a Rare Severe Case with Fetal Bladder Complications

    Directory of Open Access Journals (Sweden)

    Myriam Delomenie

    2015-01-01

    Full Text Available Carbon monoxide poisoning during pregnancy is a rare and potentially serious condition. Fetal complications are uncommon, related to anoxic lesions. The severity of these complications does not depend on the level of maternal COHb. We report the case of a 22-year-old pregnant woman who at 30 weeks of gestation had carbon monoxide poisoning secondary to a fire in her home, complicated by cardiac arrest and severe fetal damage. The child had not brain damage, but presented bladder lesions not previously described, with urinary ascites complicating megacystis.

  4. Isolated symmetrical bilateral basal ganglia T2 hyperintensity in carbon monoxide poisoning

    Directory of Open Access Journals (Sweden)

    Subhaschandra S

    2008-01-01

    Full Text Available Carbon monoxide poisoning is not uncommon during the winter months. To make a diagnosis, strong clinical suspicion and acumen, and history of the exposure are necessary. Many a time, the presenting complaints may fail to help reach a diagnosis, in the absence of history. Imaging plays a role in the diagnosis of brain injury with the characteristic features, which are correlated with the clinical profile. Isolated bilateral basal ganglia injury revealing T2 hyperintensity in MRI may be observed in acute carbon monoxide poisoning.

  5. Untangling the Energetics and Dynamics of Boron Monoxide Radical Reactions (11BO; X2Sigma+)

    Science.gov (United States)

    2015-04-15

    energy-density molecules and builds up on our previously successful synthesis of higher carbon oxides COx (x=3-6). Higher-order carbon sulfides - carbon...3.1. Crossed Beam Reactions of Boron Monoxide with Acetylene anmd Ethylene (P1, P8) The reaction dynamics of boron monoxide (BO; X2Σ...with acetylene (C2H2; X1Σg+) and with ethylene (C2H4; X1Ag) were investigated under single collision conditions at collision energy of 12 to 13 kJ mol

  6. 77 FR 31351 - Adequacy Determination for Aspen PM10 and Fort Collins Carbon Monoxide Maintenance Plans' Motor...

    Science.gov (United States)

    2012-05-25

    ... 93.118(e)(4), which was promulgated August 15, 1997 (62 FR 43780). We described our process for... (69 FR 40004). In addition, in certain areas with monitored ambient carbon monoxide (CO) values... AGENCY Adequacy Determination for Aspen PM and Fort Collins Carbon Monoxide Maintenance Plans'...

  7. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  8. A novel broadband waterborne acoustic absorber

    Science.gov (United States)

    Wang, Changxian; Wen, Weibin; Huang, Yixing; Chen, Mingji; Lei, Hongshuai; Fang, Daining

    2016-07-01

    In this paper, we extended the ray tracing theory in polar coordinate system, and originally proposed the Snell-Descartes law in polar coordinates. Based on these theories, a novel broadband waterborne acoustic absorber device was proposed. This device is designed with gradient-distributing materials along radius, which makes the incidence acoustic wave ray warps. The echo reduction effects of this device were investigated by finite element analysis, and the numerical results show that the reflectivity of acoustic wave for the new device is lower than that of homogenous and Alberich layers in almost all frequency 0-30 kHz at the same loss factor.

  9. DHCAL with Minimal Absorber: Measurements with Positrons

    CERN Document Server

    Freund, B; Repond, J.; Schlereth, J.; Xia, L.; Dotti, A.; Grefe, C.; Ivantchenko, V.; Antequera, J.Berenguer; Calvo Alamillo, E.; Fouz, M.C.; Marin, J.; Puerta-Pelayo, J.; Verdugo, A.; Brianne, E.; Ebrahimi, A.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Irles, A.; Krivan, F.; Krüger, K.; Kvasnicka, J.; Lu, S.; Lutz, B.; Morgunov, V.; Provenza, A.; Reinecke, M.; Sefkow, F.; Schuwalow, S.; Tran, H.L.; Garutti, E.; Laurien, S.; Matysek, M.; Ramilli, M.; Schroeder, S.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kovalcuk, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; van Doren, B.; Wilson, G.W.; Kawagoe, K.; Hirai, H.; Sudo, Y.; Suehara, T.; Sumida, H.; Takada, S.; Tomita, T.; Yoshioka, T.; Bilokin, S.; Bonis, J.; Cornebise, P.; Pöschl, R.; Richard, F.; Thiebault, A.; Zerwas, D.; Hostachy, J.Y.; Morin, L.; Besson, D.; Chadeeva, M.; Danilov, M.; Markin, O.; Popova, E.; Gabriel, M.; Goecke, P.; Kiesling, C.; Kolk, N.van der; Simon, F.; Szalay, M.; Corriveau, F.; Blazey, G.C.; Dyshkant, A.; Francis, K.; Zutshi, V.; Kotera, K.; Ono, H.; Takeshita, T.; Ieki, S.; Kamiya, Y.; Ootani, W.; Shibata, N.; Jeans, D.; Komamiya, S.; Nakanishi, H.

    2016-01-01

    In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

  10. Impedance matched thin metamaterials make metals absorbing.

    Science.gov (United States)

    Mattiucci, N; Bloemer, M J; Aközbek, N; D'Aguanno, G

    2013-11-13

    Metals are generally considered good reflectors over the entire electromagnetic spectrum up to their plasma frequency. Here we demonstrate an approach to tailor their absorbing characteristics based on the effective metamaterial properties of thin, periodic metallo-dielectric multilayers by exploiting a broadband, inherently non-resonant, surface impedance matching mechanism. Based on this mechanism, we design, fabricate and test omnidirectional, thin ( 99%) over a frequency range spanning from the UV to the IR. Our approach opens new venues to design cost effective materials for many applications such as thermo-photovoltaic energy conversion devices, light harvesting for solar cells, flat panel display, infrared detectors, stray light reduction, stealth and others.

  11. Acoustical model of a Shoddy fibre absorber

    Science.gov (United States)

    Manning, John Peter

    Shoddy fibres or "Shoddies" are a mixture of post-consumer and post-industrial fibres diverted from textile waste streams and recycled into their raw fibre form. They have found widespread use as a raw material for manufacturing sound absorbers that include, but are not limited to: automotive, architectural and home appliance applications. The purpose of this project is to develop a simple acoustic model to describe the acoustic behaviour of sound absorbers composed primarily of Shoddy fibres. The model requires knowledge of the material's bulk density only. To date, these materials have not been the focus of much published research and acoustical designers must rely on models that were developed for other materials or are overly complex. For modelling purposes, an equivalent fluid approach is chosen to balance complexity and accuracy. In deriving the proposed model, several popular equivalent fluid models are selected and the required input parameters for each model identified. The models are: the model of Delaney and Bazley, two models by Miki, the model of Johnson in conjunction with the model of Champoux and Allard and the model of Johnson in conjunction with the model of Lafarge. Characterization testing is carried out on sets of Shoddy absorbers produced using three different manufacturing methods. The measured properties are open porosity, tortuosity, airflow resistivity, the viscous and thermal characteristic lengths and the static thermal permeability. Empirical relationships between model parameters and bulk density are then derived and used to populate the selected models. This yields several 'simplified' models with bulk density as the only parameter. The most accurate model is then selected by comparing each model's prediction to the results of normal incidence sound absorption tests. The model of Johnson-Lafarge populated with the empirical relations is the most accurate model over the range of frequencies considered (approx. 300 Hz - 4000 Hz

  12. A variable passive low-frequency absorber

    DEFF Research Database (Denmark)

    Larsen, Niels Werner; Thompson, Eric Robert; Gade, Anders

    2005-01-01

    typically been too expensive or requires too much space to be practical for multi-purpose halls. Measurements were made on a variable low-frequency absorber to develop a practical solution to the dilemma. The paper will present the results of the measurements as well as a possible design.......Multi-purpose concert halls face a dilemma. They can host classical music concerts, rock concerts and spoken word performances in a matter of a short period. These different performance types require significantly different acoustic conditions in order to provide the best sound quality to both...

  13. Outflows vs. Clouds in AGN Intrinsic Absorbers

    OpenAIRE

    Arav, Nahum

    2003-01-01

    We discuss the crucial role of a dynamical picture in the analysis of AGN intrinsic absorbers data. High quality FUSE data of Mrk 279 are used to demonstrate that the line of sight covering fraction is a strong function of velocity. In Mrk 279, as well as in most cases where the data is of high enough quality, the shape of the absorption troughs is mainly determined by the velocity-dependent covering fraction. We argue that the traditional ``cloud'' picture of AGN outflows is hard pressed to ...

  14. Electrochemical oxidation of carbon monoxide: from platinum single crystals to low temperature fuel cells catalysts. Part I: Carbon monoxide oxidation onto low index platinum single crystals

    Directory of Open Access Journals (Sweden)

    PHILIP N. ROSS JR

    2001-12-01

    Full Text Available The electrochemical oxidation of carbon monoxide and the interfacial structure of the CO adlayer (COads on platinum low index single crystals, Pt(111, Pt(100 and two reconstruction of Pt(110, were examined using the rotation disk electrode method in combination with the in situ surface X-ray diffraction scattering technique. The mechanism of CO oxidation is discussed on the basis of the findings that, depending on the potential, two energetic states of COads exist on the platinum surfaces. Thus, at lower potentials, weakly bonded states (COads,w and at higher potentials strongly bonded states (COads,s are formed. The mechanism of the oxidation of hydrogen-carbon monoxide mixtures is also proposed.

  15. Digital PCR using micropatterned superporous absorbent array chips.

    Science.gov (United States)

    Wang, Yazhen; Southard, Kristopher M; Zeng, Yong

    2016-06-21

    Digital PCR (dPCR) is an emerging technology for genetic analysis and clinical diagnostics. To facilitate the widespread application of dPCR, here we developed a new micropatterned superporous absorbent array chip (μSAAC) which consists of an array of microwells packed with highly porous agarose microbeads. The packed beads construct a hierarchically porous microgel which confers superior water adsorption capacity to enable spontaneous filling of PDMS microwells for fluid compartmentalization without the need of sophisticated microfluidic equipment and operation expertise. Using large λ-DNA as the model template, we validated the μSAAC for stochastic partitioning and quantitative digital detection of DNA molecules. Furthermore, as a proof-of-concept, we conducted dPCR detection and single-molecule sequencing of a mutation prevalent in blood cancer, the chromosomal translocation t(14;18), demonstrating the feasibility of the μSAAC for analysis of disease-associated mutations. These experiments were carried out using the standard molecular biology techniques and instruments. Because of its low cost, ease of fabrication, and equipment-free liquid partitioning, the μSAAC is readily adaptable to general lab settings, which could significantly facilitate the widespread application of dPCR technology in basic research and clinical practice.

  16. Phosphorene quantum dot saturable absorbers for ultrafast fiber lasers

    Science.gov (United States)

    Du, J.; Zhang, M.; Guo, Z.; Chen, J.; Zhu, X.; Hu, G.; Peng, P.; Zheng, Z.; Zhang, H.

    2017-01-01

    We fabricate ultrasmall phosphorene quantum dots (PQDs) with an average size of 2.6 ± 0.9 nm using a liquid exfoliation method involving ultrasound probe sonication followed by bath sonication. By coupling the as-prepared PQDs with microfiber evanescent light field, the PQD-based saturable absorber (SA) device exhibits ultrafast nonlinear saturable absorption property, with an optical modulation depth of 8.1% at the telecommunication band. With the integration of the all-fiber PQD-based SA, a continuous-wave passively mode-locked erbium-doped (Er-doped) laser cavity delivers stable, self-starting pulses with a pulse duration of 0.88 ps and at the cavity repetition rate of 5.47 MHz. Our results contribute to the growing body of work studying the nonlinear optical properties of ultrasmall PQDs that present new opportunities of this two-dimensional (2D) nanomaterial for future ultrafast photonic technologies. PMID:28211471

  17. Phosphorene quantum dot saturable absorbers for ultrafast fiber lasers

    Science.gov (United States)

    Du, J.; Zhang, M.; Guo, Z.; Chen, J.; Zhu, X.; Hu, G.; Peng, P.; Zheng, Z.; Zhang, H.

    2017-02-01

    We fabricate ultrasmall phosphorene quantum dots (PQDs) with an average size of 2.6 ± 0.9 nm using a liquid exfoliation method involving ultrasound probe sonication followed by bath sonication. By coupling the as-prepared PQDs with microfiber evanescent light field, the PQD-based saturable absorber (SA) device exhibits ultrafast nonlinear saturable absorption property, with an optical modulation depth of 8.1% at the telecommunication band. With the integration of the all-fiber PQD-based SA, a continuous-wave passively mode-locked erbium-doped (Er-doped) laser cavity delivers stable, self-starting pulses with a pulse duration of 0.88 ps and at the cavity repetition rate of 5.47 MHz. Our results contribute to the growing body of work studying the nonlinear optical properties of ultrasmall PQDs that present new opportunities of this two-dimensional (2D) nanomaterial for future ultrafast photonic technologies.

  18. Tracking Performances of Several Front-Absorber Designs

    CERN Document Server

    Lautridou, P; CERN. Geneva; Métivier, V; Rahmani, A; Ramillien, V; Reposeur, T; Morsch, Andreas; Cussonneau, J P

    1998-01-01

    The tracking performances of the ALICE forward muon spectrometer are investigated for several front-absorbers designs. The obtained mass resolution is compared to the one of the absorber proposed in the LOI. Out of punchthrough considerations, two absorbers compositions, including a Carbon+Concrete sandwich design, allow to reach the requested mass resolution for the Y's. Almost identical behaviours are observed versus rapidity and transverse momentum of resonances for both new candidates. These proposed designs improve the mass resolution performances and could stand as suitable absorber options for the forward muon spectrometer of ALICE. The Carbon+Concrete absorber has been retained for the Technical Proposal [1].

  19. Heat Transfer Performance of Absorber of Absorption Refrigerating Machine

    Science.gov (United States)

    Kunugi, Yoshifumi; Ouchi, Tomihisa; Usui, Sanpei; Fukuda, Tamio

    Experimental studies on heat transfer performance of absorber for lithium bromide-water absorption refrigerating machine are presented in this paper. Experimental apparatus for 35 kW evaporator and absorber, and outer grooved tubes are used. As a result, over-al1 coefficient of heat transmission of absorber has a maximum value, in the case of heat transfer area ratio of absorber to evaporator, is about 0.8. Heat transfer rate of absorber is increased by 60% by using the outer grooved tube compared with the plane surfaced tube.

  20. Warm absorbers in active galactic nuclei

    CERN Document Server

    Reynolds, C S; Reynolds, C S; Fabian, A C

    1995-01-01

    Recent {\\it ASCA} observations confirm the presence of X-ray absorption due to partially ionized gas in many Seyfert 1 galaxies; the so-called warm absorber. Constraints on the location of the warm material are presented with the conclusion that this material lies at radii coincident with, or just outside, the broad-line region. The stability of this warm material to isobaric perturbations under the assumptions of thermal and photoionization equilibrium is also studied. It is shown that there is a remarkably small range of ionization parameter, \\xi, for which the warm absorber state is stable. The robustness of this result to changes in the shape of the primary continuum, the assumed density and optical depth is investigated. Given the constraints on the location and the stability properties of the material, several models for the environments of Seyfert nuclei are discussed. These attempt to explain the presence of significant amounts of partially ionized material. In particular, various models of the broad-...

  1. Possible Quantum Absorber Effects in Cortical Synchronization

    Science.gov (United States)

    Kämpf, Uwe

    The Wheeler-Feynman transactional "absorber" approach was proposed originally to account for anomalous resonance coupling between spatio-temporally distant measurement partners in entangled quantum states of so-called Einstein-Podolsky-Rosen paradoxes, e.g. of spatio-temporal non-locality, quantum teleportation, etc. Applied to quantum brain dynamics, however, this view provides an anticipative resonance coupling model for aspects of cortical synchronization and recurrent visual action control. It is proposed to consider the registered activation patterns of neuronal loops in so-called synfire chains not as a result of retarded brain communication processes, but rather as surface effects of a system of standing waves generated in the depth of visual processing. According to this view, they arise from a counterbalance between the actual input's delayed bottom-up data streams and top-down recurrent information-processing of advanced anticipative signals in a Wheeler-Feynman-type absorber mode. In the framework of a "time-loop" model, findings about mirror neurons in the brain cortex are suggested to be at least partially associated with temporal rather than spatial mirror functions of visual processing, similar to phase conjugate adaptive resonance-coupling in nonlinear optics.

  2. An Energy Absorber with Force Modificator

    Institute of Scientific and Technical Information of China (English)

    SU Hao; ZHANG Xiaowei; YU Tongxi

    2006-01-01

    Thin-walled tubes are extensively applied in engineering,especially in vehicle structures to resist axial or traversal impact loads,for their excellent energy absorbing capacity.However,in the axial deformation mode,the force history has an extremely high peak force which may bring not only fatal injury to occupants but also damage to structures,cargo and environment.Aiming to develop energy absorbers with impact-force modificator,square metal tube with force modificator is investigated which can monitor the force-deformation history of the tube.A small device is designed to serve as an impact-force modificator,which introduces desired imperfections to the square tube just before the impact happens between the impactor and the tube,so as to reduce the peak force.Prototypes with various governing parameters were manufactured and tested both quasi-statically and dynamically to study the effects of these parameters on the characteristics of energy absorption.The results show that the force modificator can achieve the desired reduction of the peak force well whilst remaining the specific energy absorption capacity of the original square tube.With future improvements,it could be applied to vehicles or roadside safety hardware to mitigate the consequences produced by traffic accidents.

  3. Recommended method for measurement of absorbency of superabsorbent polymers in cement-based materials

    DEFF Research Database (Denmark)

    Esteves, Luis Pedro

    2015-01-01

    —laser diffraction particle size analysis, and it allows an easy and reliable measurement of the absorbency of superabsorbent polymers. It is shown in detail how both the definition of the exposure liquid and the definition of the system of SAP particles can be selected so that absorbency can be experimentally...... of superabsorbent polymers in cementitious environments is well determined. It is vital that a generalized agreement over which method should be utilized with this regard is obtained, so large-scale industrial applications can be developed with sufficient quality and safeguards. There ought to be a standard method...... so that the properties of concrete with superabsorbent polymers can be better controlled in practice. In this paper, a technique that can be potentially used as a standard method is developed. The method is based on a measurement technique validated through an international standard procedure...

  4. High-flux solar absorber concept for central receiver power plants

    Science.gov (United States)

    Pomeroy, B. D.; Roberts, J. M.; Narayanan, T. V.

    1981-02-01

    For cylindrical receivers with a capacity of about 400 MW/t, an aim-at-the belt focusing strategy can produce average fluxes the order of 0.5 MW/sq m with peaks as high as 2 MW/sq m. An absorber concept is described which uses liquid sodium coolant and a three-header configuration to efficiently capture this solar power. The mechanical design of this absorber is discussed and thermal performance estimates are presented showing the solar-capture efficiency over a range of solar intensities. The sodium-flow characteristics and some potential flow-control problems are also described. A thermal-stress analysis is presented which shows that a limiting factor on the flux capability may be tube-wall creep/fatigue failure and not the heat-transfer capability of sodium.

  5. Black phosphorus based saturable absorber for Nd-ion doped pulsed solid state laser operation

    Science.gov (United States)

    Han, S.; Zhang, F.; Wang, M.; Wang, L.; Zhou, Y.; Wang, Z.; Xu, X.

    2016-12-01

    In this paper, the use of black phosphorus (BP) as a saturable absorber in a Q-switched Nd-ion doped solid state laser is presented. Few layers of BP in isopropyl alcohol are obtained by liquid phase exfoliation. The BP nanosheets with thicknesses in the range of 15-20 nm are deposited onto a K9 glass substrate. By inserting the BP nanosheets into a diode pumped Nd-ion doped solid state laser, stable Q-switched lasing at 0.9, 1.06, 1.3 μm is obtained. Using this approach, we have achieved a short pulse duration down to 219 ns, a high pulse energy of up to 6.5 μJ, and the corresponding peak power of 30 W. Our results show that the BP saturable absorber functions well in a Nd-ion doped solid state laser for pulsed laser generation.

  6. Carbon nanotube scaffolds with controlled porosity as electromagnetic absorbing materials in the gigahertz range.

    Science.gov (United States)

    González, M; Crespo, M; Baselga, J; Pozuelo, J

    2016-05-19

    Control of the microscopic structure of CNT nanocomposites allows modulation of the electromagnetic shielding in the gigahertz range. The porosity of CNT scaffolds has been controlled by two freezing protocols and a subsequent lyophilization step: fast freezing in liquid nitrogen and slow freezing at -20 °C. Mercury porosimetry shows that slowly frozen specimens present a more open pore size (100-150 μm) with a narrow distribution whereas specimens frozen rapidly show a smaller pore size and a heterogeneous distribution. 3D-scaffolds containing 3, 4, 6 and 7% CNT were infiltrated with epoxy and specimens with 2, 5 and 8 mm thicknesses were characterized in the GHz range. Samples with the highest pore size and porosity presented the lowest reflected power (about 30%) and the highest absorbed power (about 70%), which allows considering them as electromagnetic radiation absorbing materials.

  7. Absorber Alignment Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. While there are many optical tools available to measure the reflector slope errors of parabolic trough solar collectors, there are few tools to measure the absorber alignment. A new method is presented here to measure the absorber alignment in two dimensions to within 0.5 cm. The absorber alignment is measured using a digital camera and four photogrammetric targets. Physical contact with the receiver absorber or glass is not necessary. The alignment of the absorber is measured along its full length so that sagging of the absorber can be quantified with this technique. The resulting absorber alignment measurement provides critical information required to accurately determine the intercept factor of a collector.

  8. Nano-Composite Superfine Nickel Powder Double Absorbent Coating Designing

    Institute of Scientific and Technical Information of China (English)

    LU Yan-hong; WANG Zhi-hui; HUANG Dong-zhen; HU Chuan-xin; ZHANG Chen-jia; LI Wan-zhi; LIANG Wen-ting

    2004-01-01

    We adopt a definite procedure to compound traditional absorbing material-superfine powder nickel and nano -SiC powder to obtain the nano-composite nickel powder, then testing the absorbing speciality of the composite powder. In virtue of computer assistant designing, we apply double-deck absorbent structure to improve absorbent effect and widen wave band. The experiment indicated that it is possible to achieve the anticipative object to improve the absorbing capability by adopting nano-composite absorbing material, but each component of the composite material must have matched electromagnetic parameter with another. For matching double-coating structure, it ought to modulate the correlativity of each factor to achieve the most matching in order to optimise the absorbent speciality.

  9. Subsidizing Liquidity

    DEFF Research Database (Denmark)

    Malinova, Katya; Park, Andreas

    2015-01-01

    Facing increased competition over the last decade, many stock exchanges changed their trading fees to maker-taker pricing, an incentive scheme that rewards liquidity suppliers and charges liquidity demanders. Using a change in trading fees on the Toronto Stock Exchange, we study whether and why...

  10. Liquid pearls

    CERN Document Server

    Bremond, Nicolas; Bibette, Jérôme

    2010-01-01

    This fluid dynamics video reports how to form liquid core capsules having a thin hydrogel elastic membrane named liquid pearls. These fish-egg like structures are initially made of a millimetric liquid drop, aqueous or not, coated with an aqueous liquid film containing sodium alginate that gels once the double drop enters a calcium chloride bath. The creation of such pearls with micrometer thick membrane requires to suppress mixing until gelling takes place. Here, we show that superimposing a two dimensional surfactant precipitation at the interface confers a transient rigidity that can damp the shear induced instability at impact. Based on this, pearls containing almost any type of liquids can be created. The video focuses on the dynamics of the entry of the compound drop into the gelling bath.

  11. Feasibility study of a lead monoxide-based dosimeter for quality assurance in radiotherapy

    Science.gov (United States)

    Kim, K. T.; Han, M. J.; Heo, Y. J.; Park, J. E.; Lee, Y. K.; Kim, J. N.; Oh, K. M.; Cho, H. L.; Choi, Y. S.; Kim, J. Y.; Nam, S. H.; Park, S. K.

    2016-11-01

    Lately, cancer has been treated using high-energy radiation, and this requires highly reliable treatment plans. Therefore, a dosimeter with excellent performance, which is capable of precise dose measurement, is critical. In current clinical practices, an ionization chamber and diode utilizing the ionization reaction mechanism are widely used. Several studies have been carried out to determine optimal materials for the detector in a dosimeter to enable diagnostic imaging. Recently, studies with lead monoxide, which was shown to have low drift current and high resolving power at a high bias, were reported with the dosimeter exhibiting a fast response time against incident photons. This research aims to investigate the feasibility of a lead monoxide-based dosimeter for QA (quality assurance) in radiotherapy. In this paper, we report that the manufactured dosimeter shows similar linearity to a silicon diode and demonstrates similar characteristics in terms of PDD (percent depth dose) results for the thimble ionization chamber. Based on these results, it is demonstrated that the lead monoxide-based dosimeter complies with radiotherapy QA requirements, namely rapid response time, dose linearity, dose rate independence. Thus, we expect the lead monoxide-based dosimeter to be used commercially in the future.

  12. CARBON MONOXIDE FLUXES OF DIFFERENT SOIL LAYERS IN UPLAND CANADIAN BOREAL FORESTS

    Science.gov (United States)

    Dark or low-light carbon monoxide fluxes at upland Canadian boreal forest sites were measured on-site with static chambers and with a laboratory incubation technique using cores from different depths at the same sites. Three different upland black spruce sites, burned in 1987,199...

  13. An infrared spectroscopic study of the adsorption of carbon monoxide on silica-supported copper oxide

    NARCIS (Netherlands)

    Jong, K.P. de; Geus, John W.; Joziasse, J.

    1980-01-01

    Adsorption of carbon monoxide at room temperature (0.1–50 Torr) on silica-supported copper oxide was studied by infrared spectroscopy. Catalysts were prepared by deposition-precipitation or impregnation. After calcination two types of adsorbed CO were identified showing absorption bands at 2136 ± 3

  14. Palladium-catalyzed carbonylative sonogashira coupling of aryl bromides using near stoichiometric carbon monoxide

    DEFF Research Database (Denmark)

    Neumann, Karoline T.; Laursen, Simon R.; Lindhardt, Anders T.

    2014-01-01

    A general procedure for the palladium-catalyzed carbonylative Sonogashira coupling of aryl bromides is reported, using near stoichiometric amounts of carbon monoxide. The method allows a broad substrate scope in moderate to excellent yields. The formed alkynone motive serves as a platform...

  15. Characterization of Fe-Co-Mn catalysts after carbon monoxide hydrogenation

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez C, S.L.; Serbia, M.A.; Baechler, R.; Orozco, J. [Laboratorio de Cinetica y Catalisis, Departamento de Quimica, Facultad de Ciencias, Universidad de Los Andes, Merida 5101A (Venezuela); e-mail: goncor@ula.ve

    2003-07-01

    An Fe-Co-Mn catalysts series after hydrogenation of carbon monoxide has been characterized. The XRD analysis shows the magnetite as main crystalline phase after reaction, in addition of carbon and carbide phases. All these phases lead to hydrogen consumption and oxidation rate changes on Fe-Co-Mn catalysts. A phase transformation superficial diagram is analysed. (Author)

  16. Synthesis of Diethyl Oxalate by a Coupling-Regeneration Reaction of Carbon Monoxide

    Institute of Scientific and Technical Information of China (English)

    Fandong Meng; Genhui Xu; Baowei Wang; Xinbin Ma

    2002-01-01

    This article describes a process for the synthesis of diethyl oxalate by a coupling reaction ofcarbon monoxide, catalyzed by palladium in the presence of ethyl nitrite. The kinetics and mechanism ofthe coupling and regeneration reaction are also discussed. This paper presents the results of a scale-uptest of the catalyst and the process based on an a priori computer simulation.

  17. Short-term effects of carbon monoxide on mortality : An analysis within the APHEA project

    NARCIS (Netherlands)

    Samoli, Evangelia; Touloumi, Giota; Schwartz, Joel; Anderson, Hugh Ross; Schindler, Christian; Forsberg, Bertil; Vigotti, Maria Angela; Vonk, Judith; Kosnik, Mitja; Skorkovsky, Jiri; Katsouyanni, Klea

    2007-01-01

    OBJECTIVES: We investigated the short-term effects of carbon monoxide on total and cardiovascular mortality in 19 European cities participating in the APHEA-2 (Air Pollution and Health: A European Approach) project. METHODS: We examined the association using hierarchical models implemented in two st

  18. The impacts of temperature on the absorption spectral lines of carbon monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jianqiang; Xu Yuanze; Gao Xiaorong; Wang Li; Wang Zeyong, E-mail: jianqguo@home.swjtu.edu.cn [College of Physical Science and Technology, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China)

    2011-02-01

    In order to study the change of temperature on the effects of carbon monoxide absorption spectral lines, first of all proceed from the principle of absorption spectra, using theoretical analysis method, and the transmission and absorption database of the high-resolution molecular educed the carbon monoxide absorption spectrum intensity of spectral lines, integrated widening line type function and absorption coefficient concerned with temperature, then we got the change curve between carbon monoxide absorption spectrum intensity of spectral lines, integrated widening line type function and absorption coefficient with temperature by the numerical simulation of MATLAB, and analyzed and discussed the relationship between the temperature and them. The results showed that the temperature on the effects of carbon monoxide absorption spectral lines, especially on an Integrated widening line type function is complex, and different laser frequencies will also affect the relationship of the line type function and the absorption coefficient change with temperature, which has important reference value for the absorption and measurement of carbon in practical application.

  19. Separation of hydrogen from carbon monoxide using a hollow fiber polyimide membrane: experimental and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Peer, M.; Mehdi Kamali, S.; Mahdeyarfar, M.; Mohammadi, T. [Research Laboratory for Separation Processes, Chemical Engineering Department, Tehran (Iran)

    2007-10-15

    The separation of hydrogen from carbon monoxide (syngas ratio adjustment) with polymeric membranes was investigated in this work. A polyimide hollow fiber membrane module was used for hydrogen separation. This polymer has shown large permeability and selectivity for hydrogen separation (selectivity of ca. 30). Permeation tests were carried out at different feed conditions. Feed flow rates were varied between 150-300 mL/min, temperature was varied in the range of 20-80 C and feed pressure was varied between 5-9 bar. Mixtures containing 0-50 % carbon monoxide were used when carrying out experiments. Measured membrane permeances for hydrogen and carbon monoxide were about 70-100 GPU (gas permeation units) and 3-5.5 GPU, respectively. In addition, a mathematical model for simulation of gas separation in hollow fiber membrane modules with all flow patterns (crossflow, countercurrent and cocurrent) was presented. This model can be used for calculation of membrane performance or its required surface area for a specific separation. Experimental results have shown good correlation with simulation results. Plasticization, competitive sorption and concentration polarization effect of carbon monoxide on membrane performance is shown with experimental results. This effect reduced hydrogen permeances in mixed gas experiments. (Abstract Copyright [2007], Wiley Periodicals, Inc.)

  20. Chemical production from waste carbon monoxide: its potential for energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Rohrmann, C.A.; Schiefelbein, G.F.; Molton, P.M.; Li, C.T.; Elliott, D.C.; Baker, E.G.

    1977-11-01

    Results of a study of the potential for energy conservation by producing chemicals from by-product or waste carbon monoxide (CO) from industrial sources are summarized. Extensive compilations of both industrial sources and uses for carbon monoxide were developed and included. Reviews of carbon monoxide purification and concentration technology and preliminary economic evaluations of carbon monoxide concentration, pipeline transportation and utilization of CO in the synthesis of ammonia and methanol are included. Preliminary technical and economic feasibility studies were made of producing ammonia and methanol from the by-product CO produced by a typical elemental phosphorus plant. Methanol synthesis appears to be more attractive than ammonia synthesis when using CO feedstock because of reduced water gas shift and carbon dioxide removal requirements. The economic studies indicate that methanol synthesis from CO appears to be competitive with conventional technology when the price of natural gas exceeds $0.82/million Btu, while ammonia synthesis from CO is probably not competitive until the price of natural gas exceeds $1.90/million Btu. It is concluded that there appears to be considerable potential for energy conservation in the chemical industry, by collecting CO rather than flaring it, and using it to make major chemicals such as ammonia and methanol.