  1. Development of monoenergetic electron beam sources for radiation-instrument calibration

    Science.gov (United States)

    Soares, C. G.; Dick, C. E.; Pruitt, J. S.; Sparrow, J. H.

    1985-05-01

    Accelerator-produced electron beams are being studied for use in obtaining the response of beta-particle dosimetry instrumenta- tion as a function of electron energy. The NBS 4 MV Van de Graaff and 500 kV cascaded rectifier accelerators are being used to generate electron beams from 200 keV to 2.5 MeV. A device capable of scanning the electron beam in two dimensions over an area large enough to cover radiation-survey instruments uniformly is attached to the beam-handling system of each accelerator. The scanned beam exits from vacuum through a 16 cm 2 window consisting of either 25 μm Kapton (for energies below 500 keV) or 100 μm aluminum. The electron beams produced have been characterized in terms of (1) spatial distribution, (2) energy spectrum, and (3) absorbed dose to plastic. Spatial distributions were determined using film, while spectra were measured using a 5 mm-deep Si surface barrier detector. An extrapolation chamber is being used for beam standardization in terms of absorbed dose to plastic.

  2. Development of monoenergetic electron beam sources for radiation-instrument calibration

    Energy Technology Data Exchange (ETDEWEB)

    Soares, C.G.; Dick, C.E.; Pruitt, J.S.; Sparrow, J.H.

    1985-05-15

    Accelerator-produced electron beams are being studied for use in obtaining the response of beta-particle dosimetry instrumentation as a function of electron energy. The NBS 4 MV Van de Graaff and 500 kV cascaded rectifier accelerators are being used to generate electron beams from 200 keV to 2.5 MeV. A device capable of scanning the electron beam in two dimensions over an area large enough to cover radiation-survey instruments uniformly is attached to the beam-handling system of each accelerator. The scanned beam exits from vacuum through a 16 cm/sup 2/ window consisting of either 25 ..mu..m Kapton (for energies below 500 keV) or 100 ..mu..m aluminum. The electron beams produced have been characterized in terms of (1) spatial distribution, (2) energy spectrum, and (3) absorbed dose to plastic. Spatial distributions were determined using film, while spectra were measured using a 5 mm-deep Si surface barrier detector. An extrapolation chamber is being used for beam standardization in terms of absorbed dose to plastic. (orig.).

  3. Laser Acceleration of Quasi-Monoenergetic Protons via Radiation Pressure Driven Thin Foil

    Science.gov (United States)

    Liu, Chuan S.; Shao, Xi; Eliasson, Bengt; Liu, T. C.; Dudnikova, Galina; Sagdeev, Roald Z.

    2011-01-01

    We present a theoretical and simulation study of laser acceleration of quasi-monoenergetic protons in a thin foil irradiated by high intensity laser light. The underlying physics of radiation pressure acceleration (RPA) is discussed, including the importance of optimal thickness and circularly polarized light for efficient acceleration of ions to quasi-monoenergetic beams. Preliminary two-dimensional simulation studies show that certain parameter regimes allow for stabilization of the Rayleigh-Taylor instability and possibility of acceleration of monoenergetic ions to an excess of 200 MeV, making them suitable for important applications such as medical cancer therapy and fast ignition.

  4. Generation of monoenergetic ion beams with a laser accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Pfotenhauer, Sebastian M.

    2009-01-29

    A method for the generation of monoenergetic proton and ion beams from a laser-based particle accelerator is presented. This method utilizes the unique space-charge effects occurring during relativistic laser-plasma interactions on solid targets in combination with a dot-like particle source. Due to this unique interaction geometry, MeV proton beams with an intrinsically narrow energy spectrum were obtained, for the first time, from a micrometer-scale laser accelerator. Over the past three years, the acceleration scheme has been consistently improved to enhance both the maximum particle energy and the reliability of the setup. The achieved degree of reliability allowed to derive the first scaling laws specifically for monoenergetic proton beams. Furthermore, the acceleration scheme was expanded on other target materials, enabling the generation of monoenergetic carbon beams. The experimental work was strongly supported by the parallel development of a complex theoretical model, which fully accounts for the observations and is in excellent agreement with numerical simulations. The presented results have an extraordinarily broad scope way beyond the current thesis: The availability of monoenergetic ion beams from a compact laser-plasma beam source - in conjunction with the unique properties of laser-produced particle beams - addresses a number of outstanding applications in fundamental research, material science and medical physics, and will help to shape a new generation of accelerators. (orig.)

  5. Laser-driven shock acceleration of monoenergetic ion beams

    CERN Document Server

    Fiuza, F; Boella, E; Fonseca, R A; Silva, L O; Haberberger, D; Tochitsky, S; Gong, C; Mori, W B; Joshi, C

    2012-01-01

    We show that monoenergetic ion beams can be accelerated by moderate Mach number collisionless, electrostatic shocks propagating in a long scale-length exponentially decaying plasma profile. Strong plasma heating and density steepening produced by an intense laser pulse near the critical density can launch such shocks that propagate in the extended plasma at high velocities. The generation of a monoenergetic ion beam is possible due to the small and constant sheath electric field associated with the slowly decreasing density profile. The conditions for the acceleration of high-quality, energetic ion beams are identified through theory and multidimensional particle-in-cell simulations. The scaling of the ion energy with laser intensity shows that it is possible to generate $\\sim 200$ MeV proton beams with state-of-the-art 100 TW class laser systems.

  6. Generating monoenergetic proton beam by using circularly polarlzed laser

    Institute of Scientific and Technical Information of China (English)

    LIU Bi-Cheng; YAN Xue-Qing; LIN Chen; Lu Yuan-Rong; GUO Zhi-Yu; FANG Jia-Xun; SHENG Zheng-Ming; LI Yu-Tong; CHEN Jia-Er

    2009-01-01

    The interaction of ultrashort intense circularly polarized laser with ultra thin overdense foil is studied by particle-in-cell simulation and analytic model.It is found that with the balance between pondermotive force and electrostatic force,highly quasi-monoenergetic proton beam can be generated by Phase Stable Acceleration(PSA)process.As in conventional accelerators,ion will be accelerated and bunched up in the longitudinal direction at the same time.

  7. High energy photon reference for radiation protection: technical design of the LINAC beam and ionization chambers; and calculation of monoenergetic conversion coefficients

    Science.gov (United States)

    Dusciac, D.; Bordy, J.-M.; Daures, J.; Blideanu, V.

    2016-09-01

    In this work, we present the results of the first part of a research project aimed at offering a complete response to dosimeters providers and nuclear physicists' demands for high-energy (6 - 9 MeV) photon beams for radiation protection purposes. Classical facilities allowing the production of high-energy photonic radiation (proton accelerators, nuclear reactors) are very rare and need large investment for development and use. A novel solution is proposed, consisting in the use of a medical linear accelerator, allowing a significant decrease of all costs.Using Monte Carlo simulations (MCNP5 and PENELOPE codes), a specifically designed electron-photon conversion target allowing for obtaining a high energy photon beam (with an average energy weighted by fluence of about 6 MeV) has been built for radiation protection purposes. Due to the specific design of the target, this "realistic" radiation protection high-energy photon beam presents a uniform distribution of air kerma rate at a distance of 1 m, over a 30 × 30 cm2 surface. Two graphite cavity ionizing chambers for ionometric measurements have been built. For one of these chambers, the charge collection volume has been measured allowing for its use as a primary standard. The second ionizing chamber is used as a transfer standard; as such it has been calibrated in a 60Co beam, and in the high energy photon beam for radiation protection.The measurements with these ionizing chambers allowed for an evaluation of the air kerma rate in the LINAC based high-energy photon beam for radiation protection: the values cover a range between 36 mGy/h and 210 mGy/h, compatible with radiation protection purposes.Finally, using Monte Carlo simulations, conversion coefficients from air kerma to dose equivalent quantities have been calculated in the range between 10 keV and 22.4 MeV, for the spectral distribution of the fluence corresponding to the beam produced by the linear accelerator of the LNE-LNHB.

  8. High energy photon reference for radiation protection: technical design of the LINAC beam and ionization chambers; and calculation of monoenergetic conversion coefficients

    Directory of Open Access Journals (Sweden)

    Dusciac D.

    2016-01-01

    Full Text Available In this work, we present the results of the first part of a research project aimed at offering a complete response to dosimeters providers and nuclear physicists’ demands for high-energy (6 – 9 MeV photon beams for radiation protection purposes. Classical facilities allowing the production of high-energy photonic radiation (proton accelerators, nuclear reactors are very rare and need large investment for development and use. A novel solution is proposed, consisting in the use of a medical linear accelerator, allowing a significant decrease of all costs.Using Monte Carlo simulations (MCNP5 and PENELOPE codes, a specifically designed electron-photon conversion target allowing for obtaining a high energy photon beam (with an average energy weighted by fluence of about 6 MeV has been built for radiation protection purposes. Due to the specific design of the target, this “realistic” radiation protection high-energy photon beam presents a uniform distribution of air kerma rate at a distance of 1 m, over a 30 × 30 cm2 surface. Two graphite cavity ionizing chambers for ionometric measurements have been built. For one of these chambers, the charge collection volume has been measured allowing for its use as a primary standard. The second ionizing chamber is used as a transfer standard; as such it has been calibrated in a 60Co beam, and in the high energy photon beam for radiation protection.The measurements with these ionizing chambers allowed for an evaluation of the air kerma rate in the LINAC based high-energy photon beam for radiation protection: the values cover a range between 36 mGy/h and 210 mGy/h, compatible with radiation protection purposes.Finally, using Monte Carlo simulations, conversion coefficients from air kerma to dose equivalent quantities have been calculated in the range between 10 keV and 22.4 MeV, for the spectral distribution of the fluence corresponding to the beam produced by the linear accelerator of the LNE-LNHB.

  9. Suppression of multiple ion bunches and generation of monoenergetic ion beams in laser foil-plasma

    Institute of Scientific and Technical Information of China (English)

    Zhang Shan; Xie Bai-Song; Hong Xue-Ren; Wu Hai-Cheng; Aimierding Aimidula; Zhao Xue-Yan; Liu Ming-Ping

    2011-01-01

    In one-dimensional particle-in-cell simulations, this paper shows that the formation of multiple ion bunches is disadvantageous to the generation of monoenergetic ion beams and can be suppressed by choosing an optimum target thickness in the radiation pressure acceleration mechanism by a circularly polarised laser pulse. As the laser pulse becomes intense, the optimum target thickness obtained by a non-relativistic treatment is no longer adequate. Considering the relativistic Doppler-shifted pressure, it proposes a relativistic formulation to determine the optimum target thickness. The theoretical predictions agree with the simulation results well. The model is also valid for two-dimensional cases. The accelerated ion beams can be compelled to be more stable by choosing the optimum target thickness when they exhibit some unstable behaviours.

  10. Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations.

    Science.gov (United States)

    Stolzmann, Paul; Winklhofer, Sebastian; Schwendener, Nicole; Alkadhi, Hatem; Thali, Michael J; Ruder, Thomas D

    2013-09-01

    The aim of this study was to assess the potential of monoenergetic computed tomography (CT) images to reduce beam hardening artifacts in comparison to standard CT images of dental restoration on dental post-mortem CT (PMCT). Thirty human decedents (15 male, 58 ± 22 years) with dental restorations were examined using standard single-energy CT (SECT) and dual-energy CT (DECT). DECT data were used to generate monoenergetic CT images, reflecting the X-ray attenuation at energy levels of 64, 69, 88 keV, and at an individually adjusted optimal energy level called OPTkeV. Artifact reduction and image quality of SECT and monoenergetic CT were assessed objectively and subjectively by two blinded readers. Subjectively, beam artifacts decreased visibly in 28/30 cases after monoenergetic CT reconstruction. Inter- and intra-reader agreement was good (k = 0.72, and k = 0.73 respectively). Beam hardening artifacts decreased significantly with increasing monoenergies (repeated-measures ANOVA p < 0.001). Artifact reduction was greatest on monoenergetic CT images at OPTkeV. Mean OPTkeV was 108 ± 17 keV. OPTkeV yielded the lowest difference between CT numbers of streak artifacts and reference tissues (-163 HU). Monoenergetic CT reconstructions significantly reduce beam hardening artifacts from dental restorations and improve image quality of post-mortem dental CT.

  11. Native cation vacancies in Si-doped AlGaN studied by monoenergetic positron beams

    Science.gov (United States)

    Uedono, A.; Tenjinbayashi, K.; Tsutsui, T.; Shimahara, Y.; Miyake, H.; Hiramatsu, K.; Oshima, N.; Suzuki, R.; Ishibashi, S.

    2012-01-01

    Native defects in Si-doped AlGaN grown by metalorganic vapor phase epitaxy were probed by monoenergetic positron beams. Doppler broadening spectra of the annihilation radiation and positron lifetimes were measured, and these were compared with results obtained using first-principles calculation. For Si-doped AlxGa1-xN (4 × 1017 Si/cm3), the vacancy-type defects were introduced at above x = 0.54, and this was attributed to the transition of the growth mode to the Stranski-Krastanov mechanism from the Frank-van der Merwe mechanism. For Si-doped Al0.6Ga0.4N, the vacancy concentration increased with increasing Si concentration, and the major defect species was identified as Al vacancies. A clear correlation between the suppression of cathodoluminescence and the defect concentration was obtained, suggesting the cation vacancies act as nonradiative centers in AlGaN.

  12. Quasi-monoenergetic positron beam generation from ultra-intense laser-matter interactions

    Science.gov (United States)

    Nakamura, Tatsufumi; Hayakawa, Takehito

    2016-10-01

    In ultra-intense laser-matter interactions in which the radiation reaction effect plays an important role, γ-rays are effectively generated that are intense, collimated, and of short duration. These γ-rays propagate through the target, which results in the electron-positron pair creation caused by the interaction of the γ-rays with the nuclear electric fields. The positron beam thus generated has several unique features; it is quasi-monoenergetic in nature with a peak energy of hundreds of MeV, well collimated, and of ultra-short duration. Based on the numerical simulations, the dependences of the number and monochromaticity of the positrons on the laser and target parameters are explored, which leads to the proposal of a new type of the laser-driven positron source.

  13. Generation of quasi-monoenergetic protons from a double-species target driven by the radiation pressure of an ultraintense laser pulse

    Science.gov (United States)

    Pae, Ki Hong; Kim, Chul Min; Nam, Chang Hee

    2016-03-01

    In laser-driven proton acceleration, generation of quasi-monoenergetic proton beams has been considered a crucial feature of the radiation pressure acceleration (RPA) scheme, but the required difficult physical conditions have hampered its experimental realization. As a method to generate quasi-monoenergetic protons under experimentally viable conditions, we investigated using double-species targets of controlled composition ratio in order to make protons bunched in the phase space in the RPA scheme. From a modified optimum condition and three-dimensional particle-in-cell simulations, we showed by varying the ion composition ratio of proton and carbon that quasi-monoenergetic protons could be generated from ultrathin plane targets irradiated with a circularly polarized Gaussian laser pulse. The proposed scheme should facilitate the experimental realization of ultrashort quasi-monoenergetic proton beams for unique applications in high field science.

  14. RBE of quasi-monoenergetic 60 MeV neutron radiation for induction of dicentric chromosomes in human lymphocytes.

    Science.gov (United States)

    Nolte, R; Mühlbradt, K-H; Meulders, J P; Stephan, G; Haney, M; Schmid, E

    2005-12-01

    The production of dicentric chromosomes in human lymphocytes by high-energy neutron radiation was studied using a quasi-monoenergetic 60 MeV neutron beam. The average yield coefficient [see text] of the linear dose-response relationship for dicentric chromosomes was measured to be (0.146+/-0.016) Gy-1. This confirms our earlier observations that above 400 keV, the yield of dicentric chromosomes decreases with increasing neutron energy. Using the linear-quadratic dose-response relationship for dicentric chromosomes established in blood of the same donor for 60Co gamma-rays as a reference radiation, an average maximum low-dose RBE (RBEM) of 14+/-4 for 60 MeV quasi-monoenergetic neutrons with a dose-weighted average energy [see text] of 41.0 MeV is obtained. A correction procedure was applied, to account for the low-energy continuum of the quasi-monoenergetic spectral neutron distribution, and the yield coefficient alpha for 60 MeV neutrons was determined from the measured average yield coefficient [see text]. For alpha, a value of (0.115+/-0.026) Gy-1 was obtained corresponding to an RBEM of 11+/-4. The present experiments extend earlier investigations with monoenergetic neutrons to higher energies.

  15. Multiple quasi-monoenergetic electron beams from laser-wakefield acceleration with spatially structured laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y.; Li, M. H.; Li, Y. F.; Wang, J. G.; Tao, M. Z.; Han, Y. J.; Zhao, J. R.; Huang, K.; Yan, W. C.; Ma, J. L.; Li, Y. T. [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Chen, L. M., E-mail: lmchen@iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China); Li, D. Z. [Institute of High Energy Physics, CAS, Beijing 100049 (China); Chen, Z. Y. [Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang, Sichuan 621999 (China); Sheng, Z. M. [Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China); Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Zhang, J. [Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2015-08-15

    By adjusting the focus geometry of a spatially structured laser pulse, single, double, and treble quasi-monoenergetic electron beams were generated, respectively, in laser-wakefield acceleration. Single electron beam was produced as focusing the laser pulse to a single spot. While focusing the laser pulse to two spots that are approximately equal in energy and size and intense enough to form their own filaments, two electron beams were produced. Moreover, with a proper distance between those two focal spots, three electron beams emerged with a certain probability owing to the superposition of the diffractions of those two spots. The energy spectra of the multiple electron beams are quasi-monoenergetic, which are different from that of the large energy spread beams produced due to the longitudinal multiple-injection in the single bubble.

  16. Development of a monoenergetic ultraslow antiproton beam source for high-precision investigation

    Directory of Open Access Journals (Sweden)

    N. Kuroda

    2012-02-01

    Full Text Available The ASACUSA collaboration developed an ultraslow antiproton beam source, monoenergetic ultraslow antiproton source for high-precision investigation (MUSASHI, consisting of an electromagnetic trap with a liquid He free superconducting solenoid and a low energy antiproton beam transport line. The MUSASHI was capable of trapping and cooling more than 1×10^{7} antiprotons and extracting them as an ultraslow antiproton beam with energy of 150–250 eV.

  17. Analysis of the response of innovative neutron detectors with monoenergetic neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Romei, C.; Ciolini, R.; Mirzajani, N.; Selici, S. [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa, Pisa (Italy); Di Fulvio, A.; D' Errico, F. [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa, Pisa (Italy); Yale University, New Haven, CT (United States); Souza, S. O. [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao (Brazil); Piotto, M. [Istituto di Ingegneria Elettronica, Computer e Telecomunicazioni, CNR, Pisa (Italy); Esposito, J.; Colautti, P. [INFN, Laboratori Nazionali di Legnaro, Legnaro (Padova) (Italy)

    2013-07-18

    Various neutron detectors are currently under development at the University of Pisa. The response of these devices is investigated using monoenergetic neutron beams produced at the CN accelerator of INFN Legnaro National Laboratories with thin lithium target bombarded by protons at different energies, exploiting the {sup 7}Li(p,n){sup 7}Be reaction.

  18. Development of a monoenergetic neutron beam (Theoretical aspects, experimental developments and applications)

    CERN Document Server

    Varela-G, A

    2003-01-01

    By the use of a neutron time of flight system at the Tandem Accelerator of the National Nuclear Research Institute; with neutrons provided by means of the sup 2 H(d, n) sup 3 He we intend to use the associated particle technique in order to have monoenergetic neutrons. This neutron beam will be used both in basic and applied research. (Author)

  19. Monoenergetic positron beam at the reactor based positron source at FRM-II

    Science.gov (United States)

    Hugenschmidt, C.; Kögel, G.; Repper, R.; Schreckenbach, K.; Sperr, P.; Straßer, B.; Triftshäuser, W.

    2002-05-01

    The principle of the in-pile positron source at the Munich research reactor FRM-II is based on absorption of high energy prompt γ-rays from thermal neutron capture in 113Cd. For this purpose, a cadmium cap is placed inside the tip of the inclined beam tube SR-11 in the moderator tank of the reactor, where an undisturbed thermal neutron flux up to 2×10 14n cm-2 s-1 is expected. Inside the cadmium cap a structure of platinum foils is placed for converting high energy γ-radiation into positron-electron pairs. Due to the negative positron work function, moderation in annealed platinum leads to emission of monoenergetic positrons. Therefore, platinum will also be used as moderator, since its moderation property seems to yield long-term stability under reactor conditions and it is much easier to handle than tungsten. Model calculations were performed with SIMION-7.0w to optimise geometry and potential of Pt-foils and electrical lenses. It could be shown that the potentials between the Pt-foils must be chosen in the range of 1-10 V to extract moderated positrons. After successive acceleration to 5 keV by four electrical lenses the beam is magnetically guided in a solenoid field of 7.5 mT resulting in a beam diameter of about 25 mm. An intensity of about 10 10 slow positrons per second is expected in the primary positron beam. Outside of the reactor shield a W(1 0 0) single crystal remoderation stage will lead to an improvement of the positron beam brilliance before the positrons are guided to the experimental facilities.

  20. Two-Colour Free Electron Laser with Wide Frequency Separation using a Single Monoenergetic Electron Beam

    CERN Document Server

    Campbell, L T; Reiche, S

    2014-01-01

    Studies of a broad bandwidth, two-colour FEL amplifier using one monoenergetic electron beam are presented. The two-colour FEL interaction is achieved using a series of undulator modules alternately tuned to two well-separated resonant frequencies. Using the broad bandwidth FEL simulation code Puffin, the electron beam is shown to bunch strongly and simultaneously at the two resonant frequencies. Electron bunching components are also generated at the sum and difference of the resonant frequencies.

  1. Summary of monoenergetic neutron beam sources for energies gt 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Brady, F.P.; Romero, J.L. (Univ. of California-Davis, Crocker Nuclear Lab., Davis, CA (US))

    1990-11-01

    This paper examines the production of neutron beams for energies between {approx}20 and 100 MeV. Considerations for obtaining monoenergetic beams as well as some of the limiting factors, such as energy resolution are examined as well. Production cross sections at 0 deg are reviewed for proton- and deuteron-induced reactions on light elements. Some current facilities in the context of neutron beams obtained by collimation, by the associate particle method, and by the use of a beam swinger are also discussed.

  2. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities.

    Science.gov (United States)

    Mansy, M S; Bashter, I I; El-Mesiry, M S; Habib, N; Adib, M

    2015-03-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5-133keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named "QMNB" was developed in the "MATLAB" programming language to perform the required calculations.

  3. Vacancy-type defects induced by grinding of Si wafers studied by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Yoshihara, Nakaaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Mizushima, Yoriko [Devices and Materials Labs Fujitsu Laboratories Ltd., Atsugi, Kanagawa 243-0197 (Japan); ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Kim, Youngsuk [ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Disco Corporation, Ota, Tokyo 143-8580 (Japan); Nakamura, Tomoji [Devices and Materials Labs Fujitsu Laboratories Ltd., Atsugi, Kanagawa 243-0197 (Japan); Ohba, Takayuki [ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Oshima, Nagayasu; Suzuki, Ryoichi [Research Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8568 (Japan)

    2014-10-07

    Vacancy-type defects introduced by the grinding of Czochralski-grown Si wafers were studied using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and the lifetime spectra of positrons showed that vacancy-type defects were introduced in the surface region (<98 nm), and the major defect species were identified as (i) relatively small vacancies incorporated in dislocations and (ii) large vacancy clusters. Annealing experiments showed that the defect concentration decreased with increasing annealing temperature in the range between 100 and 500°C. After 600–700°C annealing, the defect-rich region expanded up to about 170 nm, which was attributed to rearrangements of dislocation networks, and a resultant emission of point defects toward the inside of the sample. Above 800°C, the stability limit of those vacancies was reached and they started to disappear. After the vacancies were annealed out (900°C), oxygen-related defects were the major point defects and they were located at <25 nm.

  4. Dense monoenergetic proton beams from chirped laser-plasma interaction

    CERN Document Server

    Galow, Benjamin J; Liseykina, Tatyana V; Harman, Zoltan; Keitel, Christoph H

    2011-01-01

    Interaction of a frequency-chirped laser pulse with single protons and a hydrogen plasma cell is studied analytically and by means of particle-in-cell simulations, respectively. Feasibility of generating ultra-intense (10^7 particles per bunch) and phase-space collimated beams of protons (energy spread of about 1 %) is demonstrated. Phase synchronization of the protons and the laser field, guaranteed by the appropriate chirping of the laser pulse, allows the particles to gain sufficient kinetic energy (around 250 MeV) required for such applications as hadron cancer therapy, from state-of-the-art laser systems of intensities of the order of 10^21 W/cm^2.

  5. Dense monoenergetic proton beams from chirped laser-plasma interaction.

    Science.gov (United States)

    Galow, Benjamin J; Salamin, Yousef I; Liseykina, Tatyana V; Harman, Zoltán; Keitel, Christoph H

    2011-10-28

    Interaction of a frequency-chirped laser pulse with single protons and a hydrogen gas target is studied analytically and by means of particle-in-cell simulations, respectively. The feasibility of generating ultraintense (10(7) particles per bunch) and phase-space collimated beams of protons (energy spread of about 1%) is demonstrated. Phase synchronization of the protons and the laser field, guaranteed by the appropriate chirping of the laser pulse, allows the particles to gain sufficient kinetic energy (around 250 MeV) required for such applications as hadron cancer therapy, from state-of-the-art laser systems of intensities of the order of 10(21) W/cm(2).

  6. Dense monoenergetic proton beams from chirped laser-plasma interaction

    Energy Technology Data Exchange (ETDEWEB)

    Galow, Benjamin J.; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); Salamin, Yousef I. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); Department of Physics, American University of Sharjah, POB 26666, Sharjah (United Arab Emirates); Liseykina, Tatyana V. [Institut fuer Physik, Universitaet Rostock, 18051 Rostock (Germany); Harman, Zoltan [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); ExtreMe Matter Institute EMMI, Planckstrasse 1, 64291 Darmstadt (Germany)

    2012-07-01

    Interaction of a frequency-chirped laser pulse with single protons and a hydrogen gas target is studied analytically and by means of particle-in-cell simulations, respectively. Feasibility of generating ultra-intense (10{sup 7} particles per bunch) and phase-space collimated beams of protons (energy spread of about 1%) is demonstrated. Phase synchronization of the protons and the laser field, guaranteed by the appropriate chirping of the laser pulse, allows the particles to gain sufficient kinetic energy (around 250 MeV) required for such applications as hadron cancer therapy, from state-of-the-art laser systems of intensities of the order of 10{sup 21} W/cm{sup 2}.

  7. Dense monoenergetic proton beams from chirped laser-plasma interaction

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jianxing; Galow, Benjamin J.; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); Salamin, Yousef I. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); Department of Physics, American University of Sharjah, POB 26666, Sharjah (United Arab Emirates); Harman, Zoltan [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, Heidelberg (Germany); ExtreMe Matter Institute EMMI, Planckstrasse 1, 64291 Darmstadt (Germany)

    2013-07-01

    Interactions of linearly and radially polarized frequency-chirped laser pulses with single protons and hydrogen gas targets are studied analytically and by means of particle-in-cell simulations, respectively. The feasibility of generating ultra-intense (10{sup 7} particles per bunch) and phase-space collimated beams of protons is demonstrated. Phase synchronization of the protons and the laser field, guaranteed by the appropriate chirping of the laser pulse, allows the particles to gain sufficient kinetic energy (around 250 MeV) required for such applications as hadron cancer therapy, from state-of-the-art laser systems of intensities of the order of 10{sup 21} W/cm{sup 2}.

  8. Precision photo-induced cross-section measurements using the monoenergetic and polarized photon beams at HIγS

    Science.gov (United States)

    Tonchev, A. P.; Howell, C. R.; Kwan, E.; Rusev, G.; Tornow, W.; Kelley, J. H.; Huibregtse, C.; Hammond, S. L.; Vieira, D.; Wilhelmy, J. B.

    2009-10-01

    A research program has been initiated at TUNL to perform precision (γ,γ') and (γ,xn) cross-section measurements on actinide nuclei using the novel source of radiation at the High Intensity Gamma-ray Source (HIγS) facility. This facility provides nearly mono-energetic (E/E ± 2%) and intense (10^8 s-1) photon beams after the recent upgrade. A precision knowledge of photoinduced processes is of practical importance for new reactor technologies, nuclear transmutation, and nuclear forensics. Our recent photodisintegration cross section measurements on radioactive ^241Am targets in the energy range from 9 < Eγ < 16 MeV will be presented. The experimental data for the ^241Am(γ,n) reaction in the giant dipole resonance energy region will be compared with statistical nuclear-model calculations.

  9. STEREO/SEPT observations of upstream particle events: almost monoenergetic ion beams

    Directory of Open Access Journals (Sweden)

    A. Klassen

    2009-05-01

    Full Text Available We present observations of Almost Monoenergetic Ion (AMI events in the energy range of 100–1200 keV detected with the Solar Electron and Proton Telescope (SEPT onboard both STEREO spacecraft. The energy spectrum of AMI events contain 1, 2, or 3 narrow peaks with the relative width at half maximum of 0.1–0.7 and their energy maxima varies for different events from 120 to 1200 keV. These events were detected close to the bow-shock (STEREO-A&B and to the magnetopause at STEREO-B as well as unexpectedly far upstream of the bow-shock and far away from the magnetotail at distances up to 1100 RE (STEREO-B and 1900 RE (STEREO-A. We discuss the origin of AMI events, the connection to the Earth's bow-shock and to the magnetosphere, and the conditions of the interplanetary medium and magnetosphere under which these AMI bursts occur. Evidence that the detected spectral peaks were caused by quasi-monoenergetic beams of protons, helium, and heavier ions are given. Furthermore, we present the spatial distribution of all AMI events from December 2006 until August 2007.

  10. Dual-fission chamber and neutron beam characterization for fission product yield measurements using monoenergetic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, C.; Fallin, B. [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Gooden, M.E., E-mail: megooden@tunl.duke.edu [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Department of Physics, North Carolina State University, Raleigh, NC 27605 (United States); Howell, C.R. [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Kelley, J.H. [Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Department of Physics, North Carolina State University, Raleigh, NC 27605 (United States); Tornow, W. [Department of Physics, Duke University, Durham, NC 27708 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Arnold, C.W.; Bond, E.M.; Bredeweg, T.A.; Fowler, M.M.; Moody, W.A.; Rundberg, R.S.; Rusev, G.; Vieira, D.J.; Wilhelmy, J.B. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Becker, J.A.; Macri, R.; Ryan, C.; Sheets, S.A.; Stoyer, M.A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); and others

    2014-09-01

    A program has been initiated to measure the energy dependence of selected high-yield fission products used in the analysis of nuclear test data. We present out initial work of neutron activation using a dual-fission chamber with quasi-monoenergetic neutrons and gamma-counting method. Quasi-monoenergetic neutrons of energies from 0.5 to 15 MeV using the TUNL 10 MV FM tandem to provide high-precision and self-consistent measurements of fission product yields (FPY). The final FPY results will be coupled with theoretical analysis to provide a more fundamental understanding of the fission process. To accomplish this goal, we have developed and tested a set of dual-fission ionization chambers to provide an accurate determination of the number of fissions occurring in a thick target located in the middle plane of the chamber assembly. Details of the fission chamber and its performance are presented along with neutron beam production and characterization. Also presented are studies on the background issues associated with room-return and off-energy neutron production. We show that the off-energy neutron contribution can be significant, but correctable, while room-return neutron background levels contribute less than <1% to the fission signal.

  11. An angular multigrid method for computing mono-energetic particle beams in Flatland

    Science.gov (United States)

    Börgers, Christoph; MacLachlan, Scott

    2010-04-01

    Beams of microscopic particles penetrating scattering background matter play an important role in several applications. The parameter choices made here are motivated by the problem of electron-beam cancer therapy planning. Mathematically, a steady particle beam penetrating matter, or a configuration of several such beams, is modeled by a boundary value problem for a Boltzmann equation. Grid-based discretization of such a problem leads to a system of algebraic equations. This system is typically very large because of the large number of independent variables in the Boltzmann equation—six if no dimension-reducing assumptions other than time independence are made. If grid-based methods are to be practical for these problems, it is therefore necessary to develop very fast solvers for the discretized problems. For beams of mono-energetic particles interacting with a passive background, but not with each other, in two space dimensions, the first author proposed such a solver, based on angular domain decomposition, some time ago. Here, we propose and test an angular multigrid algorithm for the same model problem. Our numerical experiments show rapid, grid-independent convergence. For high-resolution calculations, our method is substantially more efficient than the angular domain decomposition method. In addition, unlike angular domain decomposition, the angular multigrid method works well even when the angular diffusion coefficient is fairly large.

  12. Optimal energy for cell radiosensitivity enhancement by gold nanoparticles using synchrotron-based monoenergetic photon beams

    Directory of Open Access Journals (Sweden)

    Rahman WN

    2014-05-01

    Full Text Available Wan Nordiana Rahman,1,2 Stéphanie Corde,3,4 Naoto Yagi,5 Siti Aishah Abdul Aziz,1 Nathan Annabell,2 Moshi Geso21School of Health Sciences, Universiti Sains Malaysia, Kelantan, Malaysia; 2Division of Medical Radiation, School of Medical Sciences, Royal Melbourne Institute of Technology, Bundoora, VIC, 3Radiation Oncology, Prince of Wales Hospital, High Street, Randwick, 4Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia; 5Japanese Synchrotron Radiation Research Institute, Sayo-gun, Hyogo, JapanAbstract: Gold nanoparticles have been shown to enhance radiation doses delivered to biological targets due to the high absorption coefficient of gold atoms, stemming from their high atomic number (Z and physical density. These properties significantly increase the likelihood of photoelectric effects and Compton scattering interactions. Gold nanoparticles are a novel radiosensitizing agent that can potentially be used to increase the effectiveness of current radiation therapy techniques and improve the diagnosis and treatment of cancer. However, the optimum radiosensitization effect of gold nanoparticles is strongly dependent on photon energy, which theoretically is predicted to occur in the kilovoltage range of energy. In this research, synchrotron-generated monoenergetic X-rays in the 30–100 keV range were used to investigate the energy dependence of radiosensitization by gold nanoparticles and also to determine the photon energy that produces optimum effects. This investigation was conducted using cells in culture to measure dose enhancement. Bovine aortic endothelial cells with and without gold nanoparticles were irradiated with X-rays at energies of 30, 40, 50, 60, 70, 81, and 100 keV. Trypan blue exclusion assays were performed after irradiation to determine cell viability. Cell radiosensitivity enhancement was indicated by the dose enhancement factor which was found to be maximum at 40 keV with a value of 3

  13. Beta-Decay Study of ^{150}Er, ^{152}Yb, and ^{156}Yb: Candidates for a Monoenergetic Neutrino Beam Facility

    Energy Technology Data Exchange (ETDEWEB)

    Estevez Aguado, M. E. [CSIC-Universidad de Valencia; Algora, A. [CSIC-Universidad de Valencia; Rubio, B. [CSIC-Universidad de Valencia; Bernabeu, J. [CSIC-Universidad de Valencia; Nacher, E. [CSIC-Universidad de Valencia; Tain, J. L. [CSIC-Universidad de Valencia; Gadea, A. [CSIC-Universidad de Valencia; Agramunt, J. [CSIC-Universidad de Valencia; Burkard, K. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Hueller, W. [GSI-Hemholtzzentrum fur Schwerionenforschung, Darmstadt, Germany; Doring, J. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Kirchner, R. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Mukha, I. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Plettner, C. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Roeckl, E. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Grawe, H. [GSI-Hemholtzzentrum fur Schwerionenforschung, Darmstadt, Germany; Collatz, R. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Hellstrom, M. [Gesellschaft fur Schwerionenforschung (GSI), Germany; Cano-Ott, D. [CIEMAT, Madrid; Karny, M. [University of Warsaw; Janas, Z. [University of Warsaw; Gierlik, M. [University of Warsaw; Plochocki, A. [University of Warsaw; Rykaczewski, Krzysztof Piotr [ORNL; Batist, L. [Petersburg Nuclear Physics Institute, Gatchina, Russia; Moroz, F. [Petersburg Nuclear Physics Institute, Gatchina, Russia; Wittman, V. [Petersburg Nuclear Physics Institute, Gatchina, Russia; Blazhev, A. [University of Cologne; Valiente, J. J. [INFN, Laboratori Nazionali di Legnaro, Italy; Espinoza, C. [CFPT-IST, Lisbon

    2011-01-01

    The beta decays of ^{150}Er, ^{152}Yb, and ^{156}Yb nuclei are investigated using the total absorption spectroscopy technique. These nuclei can be considered possible candidates for forming the beam of a monoenergetic neutrino beam facility based on the electron capture (EC) decay of radioactive nuclei. Our measurements confirm that for the cases studied, the EC decay proceeds mainly to a single state in the daughter nucleus.

  14. SEE Measurements and Simulations Using Mono-Energetic GeV-Energy Hadron Beams

    CERN Document Server

    Alia, Ruben Garcia; Brugger, Markus; Roed, Ketil; Uznanski, Slawosz; Wrobel, Frederic; Ferlet-Cavrois, Veronique; Danzeca, Salvatore; Saigne, Frederic; Spiezia, Giovanni

    2013-01-01

    Single Event Upset (SEU) measurements were performed on the ESA SEU Monitor using mono-energetic GeV-energy hadron beams available in the North Experimental Area at CERN. A 400 GeV proton beam in the H4IRRAD test area and a 120 GeV mixed pion and proton beam at the CERN-EU high Energy Reference Field facility (CERF) were used for this purpose. The resulting cross section values are presented and discussed as well as compared to the several hundred MeV case (typical for standard test facilities) from a physical interaction perspective with the intention of providing a more general understanding of the behavior. Moreover, the implications of the cross section dependence with energy above the several hundred MeV range are analyzed for different environments. In addition, analogous measurements are proposed for Single Event Latchup (SEL), motivated by discussed simulation results. Finally, a brief introduction of the future CHARM (CERN High-energy AcceleratoR Mixed facility) test installation is included.

  15. Self-Injection and Acceleration of Monoenergetic Electron Beams from Laser Wakefield Accelerators in a Highly Relativistic Regime

    Institute of Scientific and Technical Information of China (English)

    H. Yoshitama; WEN Xian-Lun; WEN Tian-Shu; WU Yu-Chi; ZHANG Bao-San; ZHU Qi-Hua; HUANG Xiao-Jun; AN Wei-Min; HUNG Wen-Hui; TANG Chuan-Xiang; LIN Yu-Zheng; T. Kameshima; WANG Xiao-Dong; CHEN Li-Ming; H. Kotaki; M. Kando; K. Nakajima; GU Yu-Qiu; GUO Yi; JIAO Chun-Ye; LIU Hong-Jie; PENG Han-Sheng; TANG Chuan-Ming; WANG Xiao-Dong

    2008-01-01

    @@ Self-injection and acceleration of monoenergetic electron beams from laser wakefield accelerators are first in-vestigated in the highly relativistic regime, using 100 TW class, 27 fs laser pulses. Quasi-monoenergetic multi-bunched beams with energies as high as multi-hundredMeV are observed with simultaneous measurements of side-scattering emissions that indicate the formation of self-channelling and self-injection of electrons into a plasma wake, referred to as a 'bubble'. The three-dimensional particle-in-cell simulations confirmed multiple self-injection of electron bunches into the bubble and their beam acceleration with gradient of 1.5 GeV/cm.

  16. Uniform heating of materials into the warm dense matter regime with laser-driven quasi-monoenergetic ion beams

    CERN Document Server

    Bang, W; Bradley, P A; Vold, E L; Boettger, J C; Fernández, J C

    2015-01-01

    In a recent experiment on the Trident laser facility, a laser-driven beam of quasi-monoenergetic aluminum ions was used to heat solid gold and diamond foils isochorically to 5.5 eV and 1.7 eV, respectively. Here theoretical calculations are presented that suggest the gold and diamond were heated uniformly by these laser-driven ion beams. According to calculations and SESAME equation-of-state tables, laser-driven aluminum ion beams achievable on Trident, with a finite energy spread of (delta E)/E ~ 20%, are expected to heat the targets more uniformly than a beam of 140 MeV aluminum ions with zero energy spread. The robustness of the expected heating uniformity relative to the changes in the incident ion energy spectra is evaluated, and expected plasma temperatures of various target materials achievable with the current experimental platform are presented.

  17. Annealing behaviors of vacancy-type defects near interfaces between metal contacts and GaN probed using a monoenergetic positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira, E-mail: uedono.akira.gb@u.tsukuba.ac.jp; Yoshihara, Nakaaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Fujishima, Tatsuya; Piedra, Daniel; Palacios, Tomás [Microsystems Technology Laboratories, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139-4307 (United States); Ishibashi, Shoji [Nanosystem Research Institute “RICS,” National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8568 (Japan); Sumiya, Masatomo [Wide Bandgap Material Group, National Institute for Materials Science, Tsukuba 305-0044 (Japan); Laboutin, Oleg; Johnson, Wayne [IQE, 200 John Hancock Road, Taunton, Massachusetts 01581 (United States)

    2014-08-04

    Vacancy-type defects near interfaces between metal contacts and GaN grown on Si substrates by metal organic chemical vapor deposition have been studied using a monoenergetic positron beam. Measurements of Doppler broadening spectra of the annihilation radiation for Ti-deposited GaN showed that optically active vacancy-type defects were introduced below the Ti/GaN interface after annealing at 800 °C. Charge transition of those defects due to electron capture was observed and was found to correlate with a yellow band in the photoluminescence spectrum. The major defect species was identified as vacancy clusters such as three to five Ga-vacancies coupled with multiple nitrogen-vacancies. The annealing behaviors of vacancy-type defects in Ti-, Ni-, and Pt-deposited GaN were also examined.

  18. Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays.

    Science.gov (United States)

    Zygmanski, Piotr; Sajo, Erno

    2016-01-01

    We review radiation transport and clinical beam modelling for gold nanoparticle dose-enhanced radiotherapy using X-rays. We focus on the nanoscale radiation transport and its relation to macroscopic dosimetry for monoenergetic and clinical beams. Among other aspects, we discuss Monte Carlo and deterministic methods and their applications to predicting dose enhancement using various metrics.

  19. Development of high pressure deuterium gas targets for the generation of intense mono-energetic fast neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Guzek, J. E-mail: jguzek@debeers.co.za; Richardson, K.; Franklyn, C.B.; Waites, A.; McMurray, W.R.; Watterson, J.I.W.; Tapper, U.A.S

    1999-06-01

    Two different technical solutions to the problem of generation of mono-energetic fast neutron beams on the gaseous targets are presented here. A simple and cost-effective design of a cooled windowed gas target system is described in the first part of this paper. It utilises a thin metallic foil window and circulating deuterium gas cooled down to 100 K. The ultimate beam handling capability of such target is determined by the properties of the window. Reliable performance of this gas target system was achieved at 1 bar of deuterium gas, when exposed to a 45 {mu}A beam of 5 MeV deuterons, for periods in excess of 6 h. Cooling of the target gas resulted in increased fast neutron output and improved neutron to gamma-ray ratio. The second part of this paper discusses the design of a high pressure, windowless gas target for use with pulsed, low duty cycle accelerators. A rotating seal concept was applied to reduce the gas load in a differentially pumped system. This allows operation at 1.23 bar of deuterium gas pressure in the gas cell region. Such a gas target system is free from the limitations of the windowed target but special attention has to be paid to the heat dissipation capability of the beam dump, due to the use of a thin target. The rotating seal concept is particularly suitable for use with accelerators such as radio-frequency quadrupole (RFQ) linacs that operate with a very high peak current at low duty cycle. The performance of both target systems was comprehensively characterized using the time-of-flight (TOF) technique. This demonstrated that very good quality mono-energetic fast neutron beams were produced with the slow neutron and gamma-ray component below 10% of the total target output.

  20. Quasi-monoenergetic electron beams from a few-terawatt laser driven plasma acceleration using a nitrogen gas jet

    Science.gov (United States)

    Rao, B. S.; Moorti, A.; Chakera, J. A.; Naik, P. A.; Gupta, P. D.

    2017-06-01

    An experimental investigation on the laser plasma acceleration of electrons has been carried out using 3 TW, 45 fs duration titanium sapphire laser pulse interaction with a nitrogen gas jet at an intensity of 2 × 1018 W cm-2. We have observed the stable generation of a well collimated electron beam with divergence and pointing variation ˜10 mrad from nitrogen gas jet plasma at an optimum plasma density around 3 × 1019 cm-3. The energy spectrum of the electron beam was quasi-monoenergetic with an average peak energy and a charge around 25 MeV and 30 pC respectively. The results will be useful for better understanding and control of ionization injection and the laser wakefield acceleration (LWFA) of electrons in high-Z gases and also towards the development of practical LWFA for various applications including injectors for high energy accelerators.

  1. Development of a monoenergetic neutron beam (Theoretical aspects, experimental developments and applications); Desarrollo de un haz de neutrones monoenergeticos (Aspectos teoricos, desarrollos experimentales y aplicaciones)

    Energy Technology Data Exchange (ETDEWEB)

    Varela G, A

    2003-07-01

    By the use of a neutron time of flight system at the Tandem Accelerator of the National Nuclear Research Institute; with neutrons provided by means of the {sup 2} H(d, n) {sup 3} He we intend to use the associated particle technique in order to have monoenergetic neutrons. This neutron beam will be used both in basic and applied research. (Author)

  2. Pulsed and monoenergetic beams for neutron cross-section measurements using activation and scattering techniques at Triangle Universities Nuclear Laboratory

    Science.gov (United States)

    Hutcheson, A.; Angell, C. T.; Becker, J. A.; Boswell, M.; Crowell, A. S.; Dashdorj, D.; Fallin, B.; Fotiades, N.; Howell, C. R.; Karwowski, H. J.; Kelley, J. H.; Kiser, M.; Macri, R. A.; Nelson, R. O.; Pedroni, R. S.; Tonchev, A. P.; Tornow, W.; Vieira, D. J.; Weisel, G. J.; Wilhelmy, J. B.

    2007-08-01

    In support of the Stewardship Science Academic Alliances initiative, an experimental program has been developed at Triangle Universities Nuclear Laboratory (TUNL) to measure (n,xn) cross-sections with both in-beam and activation techniques with the goal of improving the partial cross-section database for the NNSA Stockpile Stewardship Program. First experimental efforts include excitation function measurements on 235,238U and 241Am using pulsed and monoenergetic neutron beams with En = 5-15 MeV. Neutron-induced partial cross-sections were measured by detecting prompt γ rays from the residual nuclei using various combinations of clover and planar HPGe detectors in the TUNL shielded neutron source area. Complimentary activation measurements using DC neutron beams have also been performed in open geometry in our second target area. The neutron-induced activities were measured in the TUNL low-background counting area. In this presentation, we include detailed information about the irradiation procedures and facilities and preliminary data on first measurements using this capability.

  3. Pulsed and monoenergetic beams for neutron cross-section measurements using activation and scattering techniques at Triangle Universities Nuclear Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hutcheson, A. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States)]. E-mail: hutch@tunl.duke.edu; Angell, C.T. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Becker, J.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Boswell, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Crowell, A.S. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Dashdorj, D. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Fallin, B. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Fotiades, N. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Howell, C.R.; Karwowski, H.J.; Kelley, J.H.; Kiser, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Macri, R.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Nelson, R.O. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Pedroni, R.S. [NC A and T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); Tonchev, A.P.; Tornow, W. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Vieira, D.J. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Weisel, G.J. [Penn State Altoona, 3000 Ivyside Park, Altoona, PA 16601 (United States); Wilhelmy, J.B. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States)

    2007-08-15

    In support of the Stewardship Science Academic Alliances initiative, an experimental program has been developed at Triangle Universities Nuclear Laboratory (TUNL) to measure (n,xn) cross-sections with both in-beam and activation techniques with the goal of improving the partial cross-section database for the NNSA Stockpile Stewardship Program. First experimental efforts include excitation function measurements on {sup 235,238}U and {sup 241}Am using pulsed and monoenergetic neutron beams with E {sub n} = 5-15 MeV. Neutron-induced partial cross-sections were measured by detecting prompt {gamma} rays from the residual nuclei using various combinations of clover and planar HPGe detectors in the TUNL shielded neutron source area. Complimentary activation measurements using DC neutron beams have also been performed in open geometry in our second target area. The neutron-induced activities were measured in the TUNL low-background counting area. In this presentation, we include detailed information about the irradiation procedures and facilities and preliminary data on first measurements using this capability.

  4. The application of metal artifact reduction (MAR) in CT scans for radiation oncology by monoenergetic extrapolation with a DECT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Schwahofer, Andrea [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiation Oncology; Clinical Center Vivantes, Neukoelln (Germany). Dept. of Radiotherapy and Oncology; Baer, Esther [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiation Oncology; Kuchenbecker, Stefan; Kachelriess, Marc [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiology; Grossmann, J. Guenter [German Cancer Research Center, Heidelberg (Germany). Dept. of Medical Physics in Radiation Oncology; Ortenau Klinikum Offenburg-Gengenbach (Germany). Dept. of Radiooncology; Sterzing, Florian [Heidelberg Univ. (Germany). Dept. of Radiation Oncology; German Cancer Research Center, Heidelberg (Germany). Dept. of Radiotherapy

    2015-07-01

    Metal artifacts in computed tomography CT images are one of the main problems in radiation oncology as they introduce uncertainties to target and organ at risk delineation as well as dose calculation. This study is devoted to metal artifact reduction (MAR) based on the monoenergetic extrapolation of a dual energy CT (DECT) dataset. In a phantom study the CT artifacts caused by metals with different densities: aluminum (ρ{sub Al} = 2.7 g/cm{sup 3}), titanium (ρ{sub Ti} = 4.5 g/cm{sup 3}), steel (ρ{sub steel} = 7.9 g/cm{sup 3}) and tungsten (ρ{sub W} = 19.3 g/cm{sup 3}) have been investigated. Data were collected using a clinical dual source dual energy CT (DECT) scanner (Siemens Sector Healthcare, Forchheim, Germany) with tube voltages of 100 kV and 140 kV (Sn). For each tube voltage the data set in a given volume was reconstructed. Based on these two data sets a voxel by voxel linear combination was performed to obtain the monoenergetic data sets. The results were evaluated regarding the optical properties of the images as well as the CT values (HU) and the dosimetric consequences in computed treatment plans. A data set without metal substitute served as the reference. Also, a head and neck patient with dental fillings (amalgam ρ = 10 g/cm{sup 3}) was scanned with a single energy CT (SECT) protocol and a DECT protocol. The monoenergetic extrapolation was performed as described above and evaluated in the same way. Visual assessment of all data shows minor reductions of artifacts in the images with aluminum and titanium at a monoenergy of 105 keV. As expected, the higher the densities the more distinctive are the artifacts. For metals with higher densities such as steel or tungsten, no artifact reduction has been achieved. Likewise in the CT values, no improvement by use of the monoenergetic extrapolation can be detected. The dose was evaluated at a point 7 cm behind the isocenter of a static field. Small improvements (around 1%) can be seen with 105 ke

  5. The application of metal artifact reduction (MAR) in CT scans for radiation oncology by monoenergetic extrapolation with a DECT scanner.

    Science.gov (United States)

    Schwahofer, Andrea; Bär, Esther; Kuchenbecker, Stefan; Grossmann, J Günter; Kachelrieß, Marc; Sterzing, Florian

    2015-12-01

    Metal artifacts in computed tomography CT images are one of the main problems in radiation oncology as they introduce uncertainties to target and organ at risk delineation as well as dose calculation. This study is devoted to metal artifact reduction (MAR) based on the monoenergetic extrapolation of a dual energy CT (DECT) dataset. In a phantom study the CT artifacts caused by metals with different densities: aluminum (ρ Al=2.7 g/cm(3)), titanium (ρ Ti=4.5 g/cm(3)), steel (ρ steel=7.9 g/cm(3)) and tungsten (ρ W=19.3g/cm(3)) have been investigated. Data were collected using a clinical dual source dual energy CT (DECT) scanner (Siemens Sector Healthcare, Forchheim, Germany) with tube voltages of 100 kV and 140 kV(Sn). For each tube voltage the data set in a given volume was reconstructed. Based on these two data sets a voxel by voxel linear combination was performed to obtain the monoenergetic data sets. The results were evaluated regarding the optical properties of the images as well as the CT values (HU) and the dosimetric consequences in computed treatment plans. A data set without metal substitute served as the reference. Also, a head and neck patient with dental fillings (amalgam ρ=10 g/cm(3)) was scanned with a single energy CT (SECT) protocol and a DECT protocol. The monoenergetic extrapolation was performed as described above and evaluated in the same way. Visual assessment of all data shows minor reductions of artifacts in the images with aluminum and titanium at a monoenergy of 105 keV. As expected, the higher the densities the more distinctive are the artifacts. For metals with higher densities such as steel or tungsten, no artifact reduction has been achieved. Likewise in the CT values, no improvement by use of the monoenergetic extrapolation can be detected. The dose was evaluated at a point 7 cm behind the isocenter of a static field. Small improvements (around 1%) can be seen with 105 keV. However, the dose uncertainty remains of the order of 10

  6. Physics and Novel Schemes of Laser Radiation Pressure Acceleration for Quasi-monoenergetic Proton Generation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chuan S. [Univ. of Maryland, College Park, MD (United States). Dept. of Physics; Shao, Xi [Univ. of Maryland, College Park, MD (United States)

    2016-06-14

    The main objective of our work is to provide theoretical basis and modeling support for the design and experimental setup of compact laser proton accelerator to produce high quality proton beams tunable with energy from 50 to 250 MeV using short pulse sub-petawatt laser. We performed theoretical and computational studies of energy scaling and Raleigh--Taylor instability development in laser radiation pressure acceleration (RPA) and developed novel RPA-based schemes to remedy/suppress instabilities for high-quality quasimonoenergetic proton beam generation as we proposed. During the project period, we published nine peer-reviewed journal papers and made twenty conference presentations including six invited talks on our work. The project supported one graduate student who received his PhD degree in physics in 2013 and supported two post-doctoral associates. We also mentored three high school students and one undergraduate student of physics major by inspiring their interests and having them involved in the project.

  7. Experimental study of the water-to-air stopping power ratio of monoenergetic carbon ion beams for particle therapy.

    Science.gov (United States)

    Sánchez-Parcerisa, D; Gemmel, A; Jäkel, O; Parodi, K; Rietzel, E

    2012-06-07

    Reference dosimetry with ionization chambers requires a number of chamber-specific and beam-specific calibration factors. For carbon ion beams, IAEA report TRS-398 yields a total uncertainty of 3% in the determination of the absorbed dose to water, for which the biggest contribution arises from the water-to-air stopping power ratio (s(w, air)), with an uncertainty of 2%. The variation of (s(w, air)) along the treatment field has been studied in several Monte Carlo works presented over the last few years. Their results were, in all cases, strongly dependent on the choice of mean ionization potentials (I-values) for air and water. A smaller dependence of (s(w, air)) with penetration depth was observed. Since a consensus on I(w, air) and I(air) has not yet been reached, the validity of such studies for clinical use cannot be assessed independently. Our approach is based on a direct experimental measurement of water-equivalent thicknesses of different air gaps at different beam energies. A theoretical expression describing the variation of the stopping power ratio with kinetic energy, s(w,air)(E), was derived from the Bethe-Bloch formula and fit to the measured data, yielding a coherent pair of I(w) and I(air) values with I(air)/I(w) = 1.157 ± 0.023. Additionally, the data from five different beam energies were combined in an average value of s(w,air) = 1.132 ± 0.003 (statistical) ± 0.003 (variation over energy range), valid for monoenergetic carbon ion beams at the plateau area of the depth dose distribution. A detailed uncertainty analysis was performed on the data, in order to assess the limitations of the method, yielding an overall standard uncertainty below 1% in s(w,air)(E). Therefore, when properly combined with the appropriate models for the fragment spectra, our experimental work can contribute to narrow the uncertainty margins currently in use in absorbed dose to water determination for dosimetry of carbon ion beam radiotherapy.

  8. Generation of monoenergetic positrons

    Energy Technology Data Exchange (ETDEWEB)

    Hulett, L.D. Jr.; Dale, J.M.; Miller, P.D. Jr.; Moak, C.D.; Pendyala, S.; Triftshaeuser, W.; Howell, R.H.; Alvarez, R.A.

    1983-01-01

    Many experiments have been performed in the generation and application of monoenergetic positron beams using annealed tungsten moderators and fast sources of /sup 58/Co, /sup 22/Na, /sup 11/C, and LINAC bremstrahlung. This paper will compare the degrees of success from our various approaches. Moderators made from both single crystal and polycrystal tungsten have been tried. Efforts to grow thin films of tungsten to be used as transmission moderators and brightness enhancement devices are in progress.

  9. Vacancy-type defects in Mg-doped GaN grown by ammonia-based molecular beam epitaxy probed using a monoenergetic positron beam

    Science.gov (United States)

    Uedono, Akira; Malinverni, Marco; Martin, Denis; Okumura, Hironori; Ishibashi, Shoji; Grandjean, Nicolas

    2016-06-01

    Vacancy-type defects in Mg-doped GaN were probed using a monoenergetic positron beam. GaN films with a thickness of 0.5-0.7 μm were grown on GaN/sapphire templates using ammonia-based molecular beam epitaxy and characterized by measuring Doppler broadening spectra. Although no vacancies were detected in samples with a Mg concentration [Mg] below 7 × 1019 cm-3, vacancy-type defects were introduced starting at above [Mg] = 1 × 1020 cm-3. The major defect species was identified as a complex between Ga vacancy (VGa) and multiple nitrogen vacancies (VNs). The introduction of vacancy complexes was found to correlate with a decrease in the net acceptor concentration, suggesting that the defect introduction is closely related to the carrier compensation. We also investigated Mg-doped GaN layers grown using In as the surfactant. The formation of vacancy complexes was suppressed in the subsurface region (≤80 nm). The observed depth distribution of defects was attributed to the thermal instability of the defects, which resulted in the introduction of vacancy complexes during the deposition process.

  10. Effect of Photon Beam Energy, Gold Nanoparticle Size and Concentration on the Dose Enhancement in Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Nahideh Gharehaghaji

    2013-02-01

    Full Text Available Introduction: Gold nanoparticles have been used as radiation dose enhancing materials in recent investigations. In the current study, dose enhancement effect of gold nanoparticles on tumor cells was evaluated using Monte Carlo (MC simulation. Methods: We used MCNPX code for MC modeling in the current study. A water phantom and a tumor region with a size of 1×1×1 cm3 loaded with gold nanoparticles were simulated. The macroscopic dose enhancement factor was calculated for gold nanoparticles with sizes of 30, 50, and 100 nm. Also, we simulated different photon beams including mono-energetic beams (50-120 keV, a Cobalt-60 beam, 6 & 18 MV photon beams of a conventional linear accelerator. Results: We found a dose enhancement factor (DEF of from 1.4 to 3.7 for monoenergetic kilovoltage beams, while the DEFs for megavoltage beams were negligible and less than 3% for all GNP sizes and concentrations. The optimum energy for higher DEF was found to be the 90 keV monoenergetic beam. The effect of GNP size was not considerable, but the GNP concentration had a substantial impact on achieved DEF in GNP-based radiation therapy. Conclusion: The results were in close agreement with some previous studies considering the effect of photon energy and GNP concentration on observed DEF. Application of GNP-based radiation therapy using kilovoltage beams is recommended.

  11. Generation of quasi-monoenergetic heavy ion beams via staged shock wave acceleration driven by intense laser pulses in near-critical plasmas

    Science.gov (United States)

    Zhang, W. L.; Qiao, B.; Shen, X. F.; You, W. Y.; Huang, T. W.; Yan, X. Q.; Wu, S. Z.; Zhou, C. T.; He, X. T.

    2016-09-01

    Laser-driven ion acceleration potentially offers a compact, cost-effective alternative to conventional accelerators for scientific, technological, and health-care applications. A novel scheme for heavy ion acceleration in near-critical plasmas via staged shock waves driven by intense laser pulses is proposed, where, in front of the heavy ion target, a light ion layer is used for launching a high-speed electrostatic shock wave. This shock is enhanced at the interface before it is transmitted into the heavy ion plasmas. Monoenergetic heavy ion beam with much higher energy can be generated by the transmitted shock, comparing to the shock wave acceleration in pure heavy ion target. Two-dimensional particle-in-cell simulations show that quasi-monoenergetic {{{C}}}6+ ion beams with peak energy 168 MeV and considerable particle number 2.1 × {10}11 are obtained by laser pulses at intensity of 1.66 × {10}20 {{W}} {{cm}}-2 in such staged shock wave acceleration scheme. Similarly a high-quality {{Al}}10+ ion beam with a well-defined peak with energy 250 MeV and spread δ E/{E}0=30 % can also be obtained in this scheme.

  12. Surface sealing using self-assembled monolayers and its effect on metal diffusion in porous low-k dielectrics studied using monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira, E-mail: uedono.akira.gb@u.tsukuba.ac.jp [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Armini, Silvia; Zhang, Yu [IMEC, Kapeldreef 75, B-3001 Heverlee, Leuven (Belgium); Kakizaki, Takeaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle, 06099 Halle (Germany); Anwand, Wolfgang; Wagner, Andreas [Institute for Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf, 01314 Dresden (Germany)

    2016-04-15

    Graphical abstract: - Highlights: • Pores with cubic pore side lengths of 1.1 and 3.1 nm coexisted in the low-k film. • For the sample without the SAM sealing process, metal atoms diffused from the top Cu/MnN layer into the OSG film and were trapped by the pores. Almost all pore interiors were covered by those metals. • For the sample damaged by a plasma etch treatment before the SAM sealing process, self-assembled molecules diffused into the OSG film, and they were preferentially trapped by larger pores. - Abstract: Surface sealing effects on the diffusion of metal atoms in porous organosilicate glass (OSG) films were studied by monoenergetic positron beams. For a Cu(5 nm)/MnN(3 nm)/OSG(130 nm) sample fabricated with pore stuffing, C{sub 4}F{sub 8} plasma etch, unstuffing, and a self-assembled monolayer (SAM) sealing process, it was found that pores with cubic pore side lengths of 1.1 and 3.1 nm coexisted in the OSG film. For the sample without the SAM sealing process, metal (Cu and Mn) atoms diffused from the top Cu/MnN layer into the OSG film and were trapped by the pores. As a result, almost all pore interiors were covered with those metals. For the sample damaged by an Ar/C{sub 4}F{sub 8} plasma etch treatment before the SAM sealing process, SAMs diffused into the OSG film, and they were preferentially trapped by larger pores. The cubic pore side length in these pores containing self-assembled molecules was estimated to be 0.7 nm. Through this work, we have demonstrated that monoenergetic positron beams are a powerful tool for characterizing capped porous films and the trapping of atoms and molecules by pores.

  13. Vacancy behavior in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers grown by a three-stage coevaporation process probed by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Islam, Muhammad M.; Sakurai, Takeaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Hugenschmidt, Christoph [Physics Department E21 and Heinz Maier-Leibnitz Zentrum (MLZ), Technische Universität München, 85748 Garching (Germany); Egger, Werner [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik, 85577 Neubiberg (Germany); Scheer, Roland; Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle, 06099 Halle (Germany); Akimoto, Katsuhiro [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan)

    2016-03-31

    Vacancy-type defects in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} (x ≅ 0.45 and 1) grown by a three-stage coevaporation process were probed using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and positron lifetime spectra showed that two different defect species coexist in the Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers, and these were identified as mono/divacancy-type defects and vacancy clusters, respectively. The vacancy clusters were mainly introduced during the third growth stage, and were located in the subsurface region. The concentration of the defects affected the short-circuit current density and the conversion efficiency of the solar cells. The defect concentration and their depth distributions varied depending on Se beam equivalent pressure, growth time, and post-growth annealing time. The behavior of the vacancy-type defects is discussed also with respect to results obtained using an electron probe micro-analyzer. - Highlights: • We applied positron annihilation to characterize Cu(In{sub 1−x}Ga{sub x})Se{sub 2}. • Defect species were identified as mono/divacancy-type defects and vacancy clusters. • The conversion efficiency increased with a decreasing vacancy concentration.

  14. Energy response of GR-200A thermoluminescence dosemeters to 60Co and to monoenergetic synchrotron radiation in the energy range 28-40 keV.

    Science.gov (United States)

    Emiro, F; Di Lillo, F; Mettivier, G; Fedon, C; Longo, R; Tromba, G; Russo, P

    2016-01-01

    The response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated (60)Co gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to (60)Co, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Propagation of an ultra intense laser pulse in an under dense plasma: production of quasi monoenergetic electron beams and development of applications; Propagation d'une impulsion laser ultra-intense dans un plasma sous-dense: generation de faisceaux d'electrons quasi monoenergetiques et developpement d'applications

    Energy Technology Data Exchange (ETDEWEB)

    Glinec, Y

    2006-09-15

    This experimental study concerns the generation of electron beams with original properties. These electrons beams originate from the interaction of an ultra-intense and short laser pulse with a gas jet. Previously, these electron beams had a large divergence and a broad spectrum. A major improvement in this field was achieved when an electron beam with low divergence (10 mrad) and a peaked spectrum (170 MeV) was observed during this thesis, using a new single shot electron spectrometer. A parametric study of the interaction allowed to observe the evolution of the electron beam. Experiments have been carried out to deepen the characterization of the electron beam. The observation of transition radiation generated by the electrons at an interface shows that the electron beam interacts with the laser pulse during the acceleration. Radial oscillations of the electron beam around the laser axis, named betatron oscillations, were also observed on the electron spectra. Such a quasi-monoenergetic spectrum is essential for many applications. In order to justify the interest of this electron beam, several applications are presented: a sub-milli-metric gamma-ray radiography of dense objects, a dose profile of the electron beam comparable to present capabilities of photon sources for radiotherapy, a very short temporal profile useful for water radiolysis and the generation of a bright X-ray source with low divergence. (author)

  16. Relative Biological Effectiveness Variation Along Monoenergetic and Modulated Bragg Peaks of a 62-MeV Therapeutic Proton Beam: A Preclinical Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhary, Pankaj; Marshall, Thomas I. [Centre for Cancer Research and Cell Biology, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Belfast (United Kingdom); Perozziello, Francesca M.; Manti, Lorenzo [Department of Physics, University of Naples Federico II and INFN Naples Section University of Naples, Naples (Italy); Currell, Frederick J.; Hanton, Fiona [Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, Belfast (United Kingdom); McMahon, Stephen J.; Kavanagh, Joy N. [Centre for Cancer Research and Cell Biology, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Belfast (United Kingdom); Cirrone, Giuseppe Antonio Pablo; Romano, Francesco [Istituto Nazionale di Fisica Nucleare, LNS, Catania (Italy); Prise, Kevin M., E-mail: k.prise@qub.ac.uk [Centre for Cancer Research and Cell Biology, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Belfast (United Kingdom); Schettino, Giuseppe [Centre for Cancer Research and Cell Biology, School of Medicine, Dentistry and Biomedical Sciences, Queen' s University Belfast, Belfast (United Kingdom); National Physical Laboratory, Teddington (United Kingdom)

    2014-09-01

    Purpose: The biological optimization of proton therapy can be achieved only through a detailed evaluation of relative biological effectiveness (RBE) variations along the full range of the Bragg curve. The clinically used RBE value of 1.1 represents a broad average, which disregards the steep rise of linear energy transfer (LET) at the distal end of the spread-out Bragg peak (SOBP). With particular attention to the key endpoint of cell survival, our work presents a comparative investigation of cell killing RBE variations along monoenergetic (pristine) and modulated (SOBP) beams using human normal and radioresistant cells with the aim to investigate the RBE dependence on LET and intrinsic radiosensitvity. Methods and Materials: Human fibroblasts (AG01522) and glioma (U87) cells were irradiated at 6 depth positions along pristine and modulated 62-MeV proton beams at the INFN-LNS (Catania, Italy). Cell killing RBE variations were measured using standard clonogenic assays and were further validated using Monte Carlo simulations and the local effect model (LEM). Results: We observed significant cell killing RBE variations along the proton beam path, particularly in the distal region showing strong dose dependence. Experimental RBE values were in excellent agreement with the LEM predicted values, indicating dose-averaged LET as a suitable predictor of proton biological effectiveness. Data were also used to validate a parameterized RBE model. Conclusions: The predicted biological dose delivered to a tumor region, based on the variable RBE inferred from the data, varies significantly with respect to the clinically used constant RBE of 1.1. The significant RBE increase at the distal end suggests also a potential to enhance optimization of treatment modalities such as LET painting of hypoxic tumors. The study highlights the limitation of adoption of a constant RBE for proton therapy and suggests approaches for fast implementation of RBE models in treatment planning.

  17. Cross-section measurements of neutron-induced reactions on GaAs using monoenergetic beams from 7.5 to 15 MeV

    Science.gov (United States)

    Raut, R.; Crowell, A. S.; Fallin, B.; Howell, C. R.; Huibregtse, C.; Kelley, J. H.; Kawano, T.; Kwan, E.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Vieira, D. J.; Wilhelmy, J. B.

    2011-04-01

    Cross-section measurements for neutron-induced reactions on GaAs have been carried out at twelve different neutron energies from 7.5 to 15 MeV using the activation technique. The monoenergetic neutron beams were produced via the H2(d,n)He3 reaction. GaAs samples were activated along with Au and Al monitor foils to determine the incident neutron flux. The activities induced by the reaction products were measured using high-resolution γ-ray spectroscopy. Cross sections for five reaction channels, viz., Ga69(n,2n)Ga68, Ga69(n,p)Zn69m, Ga71(n,p)Zn71m, As75(n,2n)As74, and As75(n,p)Ge75, are reported. The results are compared with the previous measurements and available data evaluations. Statistical-model calculations, based on the Hauser-Feshbach formalism, have been carried out using the TALYS and the COH3 codes and are compared with the experimental results.

  18. Cross Section Measurements of Neutron Induced Reactions on GaAs using Monoenergetic Beams from 7.5 to 15 MeV

    Science.gov (United States)

    Raut, R.; Crowell, A. S.; Fallin, B.; Howell, C. R.; Huibregtse, C.; Kelley, J. H.; Kawano, T.; Kwan, E.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Vieira, D. J.; Wilhelmy, J. B.

    2011-09-01

    Cross section measurements for the neutron induced reactions on GaAs have been carried out at ten different neutron energies from 7.5 to 15 MeV, using the activation technique. The monoenergetic neutron beams were produced via the 2H(d,n)3He reaction, known for it's high neutron yield in the chosen energy regime. GaAs samples were activated along with the Au and Al monitor foils, for estimating the incident neutron flux. The induced activiy was measured using high resolution γ-ray spectroscopy. Five reaction channels viz., 69Ga(n, 2n) Ga, 69Ga(n,p)69mZn, 71Ga(n,p)71mZn, 75As(n, 2n)74As and 75As(n,p)75Ge, have been reported for the comprehensive cross section measurements. The results are compared with the existing literature data and the available evaluations. Statistical model calculations, based on the Hauser-Feshbach formalism, have been carried out using the TALYS and EMPIRE codes and are compared with the experimental values.

  19. Electromagnetic radiation from beam-plasma instabilities

    Science.gov (United States)

    Pritchett, P. L.; Dawson, J. M.

    1983-01-01

    A computer simulation is developed for the generation of electromagnetic radiation in an electron beam-plasma interaction. The plasma is treated as a two-dimensional finite system, and effects of a continuous nonrelativistic beam input are accounted for. Three momentum and three field components are included in the simulation, and an external magnetic field is excluded. EM radiation generation is possible through interaction among Langmuir oscillations, ion-acoustic waves, and the electromagnetic wave, producing radiation perpendicular to the beam. The radiation is located near the plasma frequency, and polarized with the E component parallel to the beam. The scattering of Langmuir waves caused by ion-acoustic fluctuations generates the radiation. Comparison with laboratory data for the three-wave interactions shows good agreement in terms of the radiation levels produced, which are small relative to the plasma thermal energy.

  20. Automatic sup sup 1 sup sup 8 F positron source supply system for a monoenergetic positron beam

    CERN Document Server

    Saito, F; Itoh, Y; Goto, A; Fujiwara, I; Kurihara, T; Iwata, R; Nagashima, Y; Hyodo, T

    2000-01-01

    A system which supplies an intense sup sup 1 sup sup 8 F (half life 110 min) positron source produced by an AVF cyclotron through sup sup 1 sup sup 8 O(p,n) sup sup 1 sup sup 8 F reaction has been constructed. Produced sup sup 1 sup sup 8 F is transferred to a low background experiment hall through a capillary. It is electro-deposited on a graphite rod and used for a source of a slow positron beam. In the meantime the next batch of target sup sup 1 sup sup 8 O water is loaded and proton irradiation proceeds. This system makes it possible to perform continuous positron beam experiments using the 18 F positron source.

  1. Relativistically Induced Transparency Acceleration (RITA) - laser-plasma accelerated quasi-monoenergetic GeV ion-beams with existing lasers?

    Science.gov (United States)

    Sahai, Aakash A.

    2013-10-01

    Laser-plasma ion accelerators have the potential to produce beams with unprecedented characteristics of ultra-short bunch lengths (100s of fs) and high bunch-charge (1010 particles) over acceleration length of about 100 microns. However, creating and controlling mono-energetic bunches while accelerating to high-energies has been a challenge. If high-energy mono-energetic beams can be demonstrated with minimal post-processing, laser (ω0)-plasma (ωpe) ion accelerators may be used in a wide-range of applications such as cancer hadron-therapy, medical isotope production, neutron generation, radiography and high-energy density science. Here we demonstrate using analysis and simulations that using relativistic intensity laser-pulses and heavy-ion (Mi ×me) targets doped with a proton (or light-ion) species (mp ×me) of trace density (at least an order of magnitude below the cold critical density) we can scale up the energy of quasi-mono-energetically accelerated proton (or light-ion) beams while controlling their energy, charge and energy spectrum. This is achieved by controlling the laser propagation into an overdense (ω0 <ωpeγ = 1) increasing plasma density gradient by incrementally inducing relativistic electron quiver and thereby rendering them transparent to the laser while the heavy-ions are immobile. Ions do not directly interact with ultra-short laser that is much shorter in duration than their characteristic time-scale (τp <<√{mp} /ω0 <<√{Mi} /ω0). For a rising laser intensity envelope, increasing relativistic quiver controls laser propagation beyond the cold critical density. For increasing plasma density (ωpe2 (x)), laser penetrates into higher density and is shielded, stopped and reflected where ωpe2 (x) / γ (x , t) =ω02 . In addition to the laser quivering the electrons, it also ponderomotively drives (Fp 1/γ∇za2) them forward longitudinally, creating a constriction of snowplowed e-s. The resulting longitudinal e--displacement from laser

  2. Enhanced damage buildup in C{sup +}-implanted GaN film studied by a monoenergetic positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Li, X. F.; Chen, Z. Q., E-mail: chenzq@whu.edu.cn; Liu, C. [Department of Physics, Hubei Nuclear Solid Physics Key Laboratory, Wuhan University, Wuhan 430072 (China); Zhang, H. J.; Kawasuso, A. [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2015-02-28

    Wurtzite GaN films grown by hydride vapor phase epitaxy were implanted with 280 keV C{sup +} ions to a dose of 6 × 10{sup 16 }cm{sup −2}. Vacancy-type defects in C{sup +}-implanted GaN were probed using a slow positron beam. The increase of Doppler broadening S parameter to a high value of 1.08–1.09 after implantation indicates introduction of very large vacancy clusters. Post-implantation annealing at temperatures up to 800 °C makes these vacancy clusters to agglomerate into microvoids. The vacancy clusters or microvoids show high thermal stability, and they are only partially removed after annealing up to 1000 °C. The other measurements such as X-ray diffraction, Raman scattering and Photoluminescence all indicate severe damage and even disordered structure induced by C{sup +}-implantation. The disordered lattice shows a partial recovery after annealing above 800 °C. Amorphous regions are observed by high resolution transmission electron microscopy measurement, which directly confirms that amorphization is induced by C{sup +}-implantation. The disordered GaN lattice is possibly due to special feature of carbon impurities, which enhance the damage buildup during implantation.

  3. Two-parametric model of electron beam in computational dosimetry for radiation processing

    Science.gov (United States)

    Lazurik, V. M.; Lazurik, V. T.; Popov, G.; Zimek, Z.

    2016-07-01

    Computer simulation of irradiation process of various materials with electron beam (EB) can be applied to correct and control the performances of radiation processing installations. Electron beam energy measurements methods are described in the international standards. The obtained results of measurements can be extended by implementation computational dosimetry. Authors have developed the computational method for determination of EB energy on the base of two-parametric fitting of semi-empirical model for the depth dose distribution initiated by mono-energetic electron beam. The analysis of number experiments show that described method can effectively consider random displacements arising from the use of aluminum wedge with a continuous strip of dosimetric film and minimize the magnitude uncertainty value of the electron energy evaluation, calculated from the experimental data. Two-parametric fitting method is proposed for determination of the electron beam model parameters. These model parameters are as follow: E0 - energy mono-energetic and mono-directional electron source, X0 - the thickness of the aluminum layer, located in front of irradiated object. That allows obtain baseline data related to the characteristic of the electron beam, which can be later on applied for computer modeling of the irradiation process. Model parameters which are defined in the international standards (like Ep- the most probably energy and Rp - practical range) can be linked with characteristics of two-parametric model (E0, X0), which allows to simulate the electron irradiation process. The obtained data from semi-empirical model were checked together with the set of experimental results. The proposed two-parametric model for electron beam energy evaluation and estimation of accuracy for computational dosimetry methods on the base of developed model are discussed.

  4. ALICE Transition Radiation Detector (TRD), test beam.

    CERN Multimedia

    2003-01-01

    Electrons and positrons can be discriminated from other charged particles using the emission of transition radiation - X-rays emitted when the particles cross many layers of thin materials. To develop such a Transition Radiation Detector(TRD) for ALICE many detector prototypes were tested in mixed beams of pions and electrons, as in the example shown here.

  5. Radiative trapping in intense laser beams

    Science.gov (United States)

    Kirk, J. G.

    2016-08-01

    The dynamics of electrons in counter-propagating, circularly polarized laser beams are shown to exhibit attractors whose ability to trap particles depends on the ratio of the beam intensities and a single parameter describing radiation reaction. Analytical expressions are found for the underlying limit cycles and the parameter range in which they are stable. In high-intensity optical pulses, where radiation reaction strongly modifies the trajectories, the production of collimated gamma-rays and the initiation of non-linear cascades of electron-positron pairs can be optimized by a suitable choice of the intensity ratio.

  6. Radiative trapping in intense laser beams

    CERN Document Server

    Kirk, J G

    2016-01-01

    The dynamics of electrons in counter-propagating, circularly polarized laser beams are shown to exhibit attractors whose ability to trap particles depends on the ratio of the beam intensities and a single parameter describing radiation reaction. Analytical expressions are found for the underlying limit cycles and the parameter range in which they are stable. In high-intensity optical pulses, where radiation reaction strongly modifies the trajectories, the production of collimated gamma-rays and the initiation of non-linear cascades of electron-positron pairs can be optimized by a suitable choice of the intensity ratio.

  7. Radiative cooling of relativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhirong [Stanford Univ., CA (United States)

    1998-05-01

    Modern high-energy particle accelerators and synchrotron light sources demand smaller and smaller beam emittances in order to achieve higher luminosity or better brightness. For light particles such as electrons and positrons, radiation damping is a natural and effective way to obtain low emittance beams. However, the quantum aspect of radiation introduces random noise into the damped beams, yielding equilibrium emittances which depend upon the design of a specific machine. In this dissertation, the author attempts to make a complete analysis of the process of radiation damping and quantum excitation in various accelerator systems, such as bending magnets, focusing channels and laser fields. Because radiation is formed over a finite time and emitted in quanta of discrete energies, he invokes the quantum mechanical approach whenever the quasiclassical picture of radiation is insufficient. He shows that radiation damping in a focusing system is fundamentally different from that in a bending system. Quantum excitation to the transverse dimensions is absent in a straight, continuous focusing channel, and is exponentially suppressed in a focusing-dominated ring. Thus, the transverse normalized emittances in such systems can in principle be damped to the Compton wavelength of the electron, limited only by the Heisenberg uncertainty principle. In addition, he investigates methods of rapid damping such as radiative laser cooling. He proposes a laser-electron storage ring (LESR) where the electron beam in a compact storage ring repetitively interacts with an intense laser pulse stored in an optical resonator. The laser-electron interaction gives rise to rapid cooling of electron beams and can be used to overcome the space charge effects encountered in a medium energy circular machine. Applications to the designs of low emittance damping rings and compact x-ray sources are also explored.

  8. Laser synchrotron radiation and beam cooling

    Energy Technology Data Exchange (ETDEWEB)

    Esarey, E.; Sprangle, P.; Ting, A. [Naval Research Lab., Washington, DC (United States)] [and others

    1995-12-31

    The interaction of intense {approx_gt} 10{sup 18} W/cm{sup 2}, short pulse ({approx_lt} 1 ps) lasers with electron beams and plasmas can lead to the generation of harmonic radiation by several mechanisms. Laser synchrotron radiation may provide a practical method for generating tunable, near monochromatic, well collimated, short pulse x-rays in compact, relatively inexpensive source. The mechanism for the generation of laser synchrotron radiation is nonlinear Thomson scattering. Short wavelengths can be generated via Thomson scattering by two methods, (i) backscattering from relativistic electron beams, in which the radiation frequency is upshifted by the relativistic factor 4{gamma}{sup 2}, and (ii) harmonic scattering, in which a multitude of harmonics are generated with harmonic numbers extending out to the critical harmonic number nc{approx_equal}a{sub 0}{sup 3} {much_gt} 1, where a{sub 0} {approx_equal}10{sup -9}{lambda}I{sup 1/2}, {lambda} is the laser wavelength in {mu}m and I is the laser intensity in W/cm{sup 2}. Laser synchrotron sources are capable of generating short ({approx_lt} ps) x-ray pulses with high peak flux ({approx_gt} 10{sup 21} photons/s) and brightness ({approx_gt}{sup 19} photons/s-mm{sup 2}-mrad{sup 2} 0.1%BW. As the electron beam radiates via Thomson scattering, it can subsequently be cooled, i.e., the beam emittance and energy spread can be reduced. This cooling can occur on rapid ({approximately} ps) time scales. In addition, electron distributions with sufficiently small axial energy spreads can be used to generate coherent XUV radiation via a laser-pumped FEL mechanism.

  9. Radiation damping in pulsed Gaussian beams

    Science.gov (United States)

    Harvey, Chris; Marklund, Mattias

    2012-01-01

    We consider the effects of radiation damping on the electron dynamics in a Gaussian-beam model of a laser field. For high intensities, i.e., with dimensionless intensity a0≫1, it is found that the dynamics divides into three regimes. For low-energy electrons (low initial γ factor, γ0) the radiation damping effects are negligible. At higher energies, but still at 2γ0a0 one is in a regime of radiation-reaction-induced electron capture. This capture is found to be stable with respect to the spatial properties of the electron beam and results in a significant energy loss of the electrons. In this regime the plane-wave model of the laser field provides a good description of the dynamics, whereas for lower energies the Gaussian-beam and plane-wave models differ significantly. Finally the dynamics is considered for the case of an x-ray free-electron laser field. It is found that the significantly lower intensities of such fields inhibit the damping effects.

  10. Radiative transfer simulations of magnetar flare beaming

    CERN Document Server

    van Putten, T; Baring, M G; Wijers, R A M J

    2016-01-01

    Magnetar giant flares show oscillatory modulations in the tails of their light curves, which can only be explained via some form of beaming. The fireball model for magnetar bursts has been used successfully to fit the phase-averaged light curves of the tails of giant flares, but so far no attempts have been made to fit the pulsations. We present a relatively simple numerical model to simulate beaming of magnetar flare emission. In our simulations, radiation escapes from the base of a fireball trapped in a dipolar magnetic field, and is scattered through the optically thick magnetosphere of the magnetar until it escapes. Beaming is provided by the presence of a relativistic outflow, as well as by the geometry of the system. We find that a simple picture for the relativistic outflow is enough to create the pulse fraction and sharp peaks observed in pulse profiles of magnetar flares, while without a relativistic outflow the beaming is insufficient to explain giant flare rotational modulations.

  11. Radiative transfer simulations of magnetar flare beaming

    Science.gov (United States)

    van Putten, T.; Watts, A. L.; Baring, M. G.; Wijers, R. A. M. J.

    2016-09-01

    Magnetar giant flares show oscillatory modulations in the tails of their light curves, which can only be explained via some form of beaming. The fireball model for magnetar bursts has been used successfully to fit the phase-averaged light curves of the tails of giant flares, but so far no attempts have been made to fit the pulsations. We present a relatively simple numerical model to simulate beaming of magnetar flare emission. In our simulations, radiation escapes from the base of a fireball trapped in a dipolar magnetic field, and is scattered through the optically thick magnetosphere of the magnetar until it escapes. Beaming is provided by the presence of a relativistic outflow, as well as by the geometry of the system. We find that a simple picture for the relativistic outflow is enough to create the pulse fraction and sharp peaks observed in pulse profiles of magnetar flares, while without a relativistic outflow the beaming is insufficient to explain giant flare rotational modulations.

  12. Characterization of Monoenergetic Neutron Reference Fields with a High Resolution Diamond Detector

    CERN Document Server

    Zimbal, A; Nolte, R; Schuhmacher, H

    2009-01-01

    A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams impinging on solid and gas targets of tritium and deuterium. The energy of the incoming particles and the variation of the angle under which the measurement is performed produce monoenergetic reference fields with different mean energies and line shapes. In this paper we present high resolution neutron spectrometry measurements of different monoenergetic reference fields. The results are compared with calculated spectra taking into account the actual target parameters. Line structures in the order of 80 keV for a neutron energy of 9 MeV were resolved. The shift of the mean energy and the increasing of the width of the ...

  13. Helical relativistic electron beam and THz radiation

    CERN Document Server

    Son, S

    2011-01-01

    A THz laser generation utilizing a helical relativistic electron beam propagating through a strong magnetic field is discussed. The initial amplification rate in this scheme is much stronger than that in the conventional free electron laser. A magnetic field of the order of Tesla can yield a radiation in the range of 0.5 to 3 THz, corresponding to the total energy of mJ and the duration of tens of pico-second, or the temporal power of the order of GW.

  14. Radiative transfer computations for optical beams

    CERN Document Server

    Kim, A D

    2003-01-01

    In this paper, we present a method for computing direct numerical simulations of narrow optical beam waves propagating and scattering in a plane-parallel medium. For these computations, we use Fourier and Chebyshev spectral methods for three-dimensional radiative transfer that also includes polar and azimuthal angle dependences. We treat anisotropic scattering with peaked forward scattering by using a Clenshaw-Curtis quadrature rule for the polar angle and an extended trapezoid rule for the azimuthal angle. To verify our results, we compare this spectral method to Monte Carlo simulations.

  15. Modelling radiation fields of ion beams in tissue-like materials

    Energy Technology Data Exchange (ETDEWEB)

    Burigo, Lucas Norberto

    2014-07-16

    Fast nuclei are ionizing radiation which can cause deleterious effects to irradiated cells. The modelling of the interactions of such ions with matter and the related effects are very important to physics, radiobiology, medicine and space science and technology. A powerful method to study the interactions of ionizing radiation with biological systems was developed in the field of microdosimetry. Microdosimetry spectra characterize the energy deposition to objects of cellular size, i.e., a few micrometers. In the present thesis the interaction of ions with tissue-like media was investigated using the Monte Carlo model for Heavy-Ion Therapy (MCHIT) developed at the Frankfurt Institute for Advanced Studies. MCHIT is a Geant4-based application intended to benchmark the physical models of Geant4 and investigate the physical properties of therapeutic ion beams. We have implemented new features in MCHIT in order to calculate microdosimetric quantities characterizing the radiation fields of accelerated nucleons and nuclei. The results of our Monte Carlo simulations were compared with recent experimental microdosimetry data. In addition to microdosimetry calculations with MCHIT, we also investigated the biological properties of ion beams, e.g. their relative biological effectiveness (RBE), by means of the modified Microdosimetric-Kinetic model (MKM). The MKM uses microdosimetry spectra in describing cell response to radiation. MCHIT+MKM allowed us to study the physical and biological properties of ion beams. The main results of the thesis are as follows: MCHIT is able to describe the spatial distribution of the physical dose in tissue-like media and microdosimetry spectra for ions with energies relevant to space research and ion-beam cancer therapy; MCHIT+MKM predicts a reduction of the biological effectiveness of ions propagating in extended medium due to nuclear fragmentation reactions; We predicted favourable biological dose-depth profiles for monoenergetic helium and

  16. Parametric injection for monoenergetic electron acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Oguchi, A; Takano, K; Hotta, E; Nemoto, K [Department of Energy Sciences Tokyo Institute of Technology 4259 Nagatsuta-cho Midori-ku Yokohama 226-8502 Japan (Japan); Zhidkov, A [Central Research Instistute of Electric Power Industry 2-6-1 Nagasaka Yokosuka Kanagawa 240-0196 Japan (Japan); Nakajima, K [High Energy Accelerator Research Organization, KEK 1-1 Oho Tsukuba Ibaraki 305-0801 Japan (Japan)], E-mail: blue-ayu@plasma.es.titech.ac.jp

    2008-05-01

    Electrons are accelerated in the laser wakefield (LWFA). This mechanism has been studied by 2D or 3D Particle In Cell simulation. However, how the electrons are injected in the wakefield is not understood. In this paper, we consider about the process of self -injection and propose new scheme. When plasma electron density modulates, parametric resonance of electron momentum is induced. The parametric resonance depends on laser waist modulation. We carried out 2D PIC simulation with the initial condition decided from resonance condition. Moreover, we analyze experimental result that generated 200-250 MeV monoenergetic electron beam with 400TW intense laser in CAEP in China.

  17. Optimization of photon beam energies in gold nanoparticle enhanced arc radiation therapy using Monte Carlo methods.

    Science.gov (United States)

    Koger, B; Kirkby, C

    2016-12-02

    As a recent area of development in radiation therapy, gold nanoparticle (GNP) enhanced radiation therapy has shown potential to increase tumour dose while maintaining acceptable levels of healthy tissue toxicity. In this study, the effect of varying photon beam energy in GNP enhanced arc radiation therapy (GEART) is quantified through the introduction of a dose scoring metric, and GEART is compared to a conventional radiotherapy treatment. The PENELOPE Monte Carlo code was used to model several simple phantoms consisting of a spherical tumour containing GNPs (concentration: 15 mg Au g(-1) tumour, 0.8 mg Au g(-1) normal tissue) in a cylinder of tissue. Several monoenergetic photon beams, with energies ranging from 20 keV to 6 MeV, as well as 100, 200, and 300 kVp spectral beams, were used to irradiate the tumour in a 360° arc treatment. A dose metric was then used to compare tumour and tissue doses from GEART treatments to a similar treatment from a 6 MV spectrum. This was also performed on a simulated brain tumour using patient computed tomography data. GEART treatments showed potential over the 6 MV treatment for many of the simulated geometries, delivering up to 88% higher mean dose to the tumour for a constant tissue dose, with the effect greatest near a source energy of 50 keV. This effect is also seen with the inclusion of bone in a brain treatment, with a 14% increase in mean tumour dose over 6 MV, while still maintaining acceptable levels of dose to the bone and brain.

  18. Smith-Purcell Radiation in View of Particle Beam Diagnostics

    CERN Document Server

    Kube, G

    2003-01-01

    The development of the next generation high quality electron beams which are necessary for future high luminosity linear colliders and short wavelengths free electron lasers requires sensitive and non-destructive beam diagnostic techniques. In this context Smith-Purcell radiation which is generated when a charged particle beam passes close to the surface of a periodic structure (diffraction grating) is under discussion as a compact and inexpensive beam profile monitor. In order to study the basic emission process of Smith-Purcell radiation also in view of possible applications for particle beam diagnostics, experimental studies were performed at the Mainz Microtron MAMI in the visible spectral region with a microfocused 855 MeV electron beam. The radiation was separated from background components, as diffracted synchrotron radiation and transition radiation generated by electrons scratching the grating surface, by exploiting their specific emission characteristics. These are the narrow emission cone in the ...

  19. Neutron-induced fission cross-section measurement of 234U with quasi-monoenergetic beams in the keV and MeV range using micromegas detectors

    Science.gov (United States)

    Tsinganis, A.; Kokkoris, M.; Vlastou, R.; Kalamara, A.; Stamatopoulos, A.; Kanellakopoulos, A.; Lagoyannis, A.; Axiotis, M.

    2017-09-01

    Accurate data on neutron-induced fission cross-sections of actinides are essential for the design of advanced nuclear reactors based either on fast neutron spectra or alternative fuel cycles, as well as for the reduction of safety margins of existing and future conventional facilities. The fission cross-section of 234U was measured at incident neutron energies of 560 and 660 keV and 7.5 MeV with a setup based on `microbulk' Micromegas detectors and the same samples previously used for the measurement performed at the CERN n_TOF facility (Karadimos et al., 2014). The 235U fission cross-section was used as reference. The (quasi-)monoenergetic neutron beams were produced via the 7Li(p,n) and the 2H(d,n) reactions at the neutron beam facility of the Institute of Nuclear and Particle Physics at the `Demokritos' National Centre for Scientific Research. A detailed study of the neutron spectra produced in the targets and intercepted by the samples was performed coupling the NeuSDesc and MCNPX codes, taking into account the energy spread, energy loss and angular straggling of the beam ions in the target assemblies, as well as contributions from competing reactions and neutron scattering in the experimental setup. Auxiliary Monte-Carlo simulations were performed with the FLUKA code to study the behaviour of the detectors, focusing particularly on the reproduction of the pulse height spectra of α-particles and fission fragments (using distributions produced with the GEF code) for the evaluation of the detector efficiency. An overview of the developed methodology and preliminary results are presented.

  20. Transverse beam shape measurements of intense proton beams using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  1. Generation of a quasi-monoenergetic high energy proton beam from a vacuum-sandwiched double layer target irradiated by an ultraintense laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Nam Kim, Kyung; Lee, Kitae, E-mail: klee@kaeri.re.kr; Hee Park, Seong; Young Lee, Ji; Uk Jeong, Young; Vinokurov, Nikolay [Center for Quantum-Beam-based Radiation Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Gi Kim, Yong [Department of Physics, Kongju National University, Kongju (Korea, Republic of)

    2014-04-15

    An acceleration mechanism to generate a high energy proton beam with a narrow energy spread in the laser-induced plasma acceleration of a proton beam is proposed; this mechanism employs two thin foils separated by a narrow vacuum gap. Instead of a thin sheath field at the plasma surfaces, it utilizes an electrostatic field formed in the bulk of the plasma. From a one-dimensional fluid analysis, it has been found that with an appropriate target thickness, protons on the front surface of the second layer can be fed into the plasma, in which the protons are accelerated by an electrostatic field built into the bulk of the plasma. This leads to a proton beam with higher energy and a narrower energy spread than those accelerated at the rear surface of the second layer. The acceleration mechanism is also verified by a two-dimensional particle-in-cell simulation. With a 27-fs long and 2×10{sup 19} W/cm{sup 2} intense laser pulse, a proton beam with an 18-MeV peak energy and a 35% energy spread is generated. The peak energy is higher than that from the rear surface of the second layer by a factor of 3.

  2. Two Effective Heuristics for Beam Angle Optimization in Radiation Therapy

    CERN Document Server

    Yarmand, Hamed

    2013-01-01

    In radiation therapy, mathematical methods have been used for optimizing treatment planning for delivery of sufficient dose to the cancerous cells while keeping the dose to critical surrounding structures minimal. This optimization problem can be modeled using mixed integer programming (MIP) whose solution gives the optimal beam orientation as well as optimal beam intensity. The challenge, however, is the computation time for this large scale MIP. We propose and investigate two novel heuristic approaches to reduce the computation time considerably while attaining high-quality solutions. We introduce a family of heuristic cuts based on the concept of 'adjacent beams' and a beam elimination scheme based on the contribution of each beam to deliver the dose to the tumor in the ideal plan in which all potential beams can be used simultaneously. We show the effectiveness of these heuristics for intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) on a clinical liver case.

  3. Power Beaming Leakage Radiation as a SETI Observable

    CERN Document Server

    Benford, James N

    2016-01-01

    The most observable leakage radiation from an advanced civilization may well be from the use of power beaming to transfer energy and accelerate spacecraft. Applications suggested for power beaming involve Earth-to-space applications such as launching spacecraft to orbit, raising satellites to a higher orbit, and interplanetary concepts involving space-to-space transfers of cargo or passengers. We also quantify beam-driven launch to the outer solar system, interstellar precursors and ultimately starships. We estimate the principal observable parameters of power beaming leakage. Extraterrestrial civilizations would know their power beams could be observed, and so could put a message on the power beam and broadcast it for our receipt at little additional energy or cost. By observing leakage from power beams we may find a message embedded on the beam. Recent observations of the anomalous star KIC 8462852 by the Allen Telescope Array (ATA) set some limits on extraterrestrial power beaming in that system. We show t...

  4. Simulation of transition radiation based beam imaging from tilted targets

    Science.gov (United States)

    Sukhikh, L. G.; Kube, G.; Potylitsyn, A. P.

    2017-03-01

    Transverse beam profile diagnostics in linear electron accelerators is usually based on direct imaging of a beam spot via visible transition radiation. In this case the fundamental resolution limit is determined by radiation diffraction in the optical system. A method to measure beam sizes beyond the diffraction limit is to perform imaging dominated by a single-particle function (SPF), i.e. when the recorded image is dominated not by the transverse beam profile but by the image function of a point source (single electron). Knowledge of the SPF for an experimental setup allows one to extract the transverse beam size from an SPF dominated image. This paper presents an approach that allows one to calculate two-dimensional SPF dominated beam images, taking into account the target inclination angle and the depth-of-field effect. In conclusion, a simple fit function for beam size determination in the case under consideration is proposed and its applicability is tested under various conditions.

  5. Microdosimetry of radiation fields from therapeutic C-12 beams in water: a study with Geant4 toolkit

    CERN Document Server

    Burigo, Lucas; Mishustin, Igor; Bleicher, Marcus

    2013-01-01

    We model the responses of Tissue-Equivalent Proportional Counters (TEPC) to radiation fields of therapeutic C-12 beams in a water phantom and to quasi-monoenergetic neutrons in a PMMA phantom. Simulations are performed with the Monte Carlo for Heavy Ion Therapy (MCHIT) model based on the Geant4 toolkit. The shapes of the calculated lineal energy spectra agree well with measurements in both cases. Measurements on the axis of a narrow C-12 beam with its width smaller than the TEPC diameter are studied in detail. The relation between LET and measured frequency-mean lineal energy yf is discussed. It is found that the choice of the nuclear fragmentation model used in MCHIT simulations has a relatively small influence on the calculated total lineal energy spectra. However, the shapes of the spectra measured with C-12 beams are better described by MCHIT calculations which take into account the production of delta-electrons. The validation of MCHIT with neutron beams gives us confidence in estimating the contribution...

  6. Nonintercepting electron beam size monitor using optical diffraction radiation interference

    Directory of Open Access Journals (Sweden)

    A. Cianchi

    2011-10-01

    Full Text Available In recent years, the use of diffraction radiation (DR, emitted when a charged particle beam passes through a rectangular slit, has been proposed and successfully tested as a nonintercepting diagnostic of high brightness beams. However, some problems related to the control of the particle trajectory through the slit still remain. If an additional slit is placed in front of the first one, at a distance shorter than the radiation formation length, interference between the forward diffraction radiation from the upstream slit and the backward diffraction radiation from the downstream slit can be observed. In this paper we report the first experimental observation of this effect, which we call here optical diffraction radiation interference (ODRI. If the two slits have different dimensions and are not aligned on the same axis, the properties of the ODRI pattern can be effectively used for nonintercepting beam diagnostics, especially for the unambiguously determination of the beam size. Indeed, the advantage of ODRI compared with a single aperture DR screen is due to the reduction of synchrotron radiation background, the increase of sensitivity for transverse beam dimensions, and the possibility to separate effects caused by the beam size and by beam offset within the slit.

  7. The radiation measurement applied to beam lifetime study on the synchrotron radiation facilities

    Science.gov (United States)

    Li, Yuxiong; Li, Juexin; Liu, Zuping; Cui, Yonggang; Gong, Guanghua; Shao, Beibei

    2003-06-01

    To collect beam loss information from an accelerator radiation field is helpful to machine study and operation. For a synchrotron radiation storage ring, shower electrons give a distinct clue to loss location and a BLM-XS model detector is suitable to detect them. Recently, we set up a new beam loss monitoring system by this method for National Synchrotron Radiation Laboratory (NSRL) storage ring. It does not interfere with the vacuum chamber and machine operation. Different from other systems, the detectors are used in pairs, fixed on opposite sides of the chamber separately. Some interesting phenomena about beam lifetime were observed. We located exactly where an excessive beam loss took place during ramping process and solved the problem. It was proved that gas accumulated at the front ends of photo-beam lines strongly impacted the electron beam and led to beam lifetime decreases. The cause of beam lifetime decrease because of superconducting wiggler is discussed.

  8. Particle beam radiation therapy:re-introducing the future

    Institute of Scientific and Technical Information of China (English)

    Omar Abdel-Rahman

    2014-01-01

    Particle radiation therapy is an exciting area of radiotherapy basic and clinical researches. The majority of particle radiotherapy work is being done with proton beams having essential y the same radiobiologic properties as conventional photon/electron radiation but al owing a much more precise control of the radiation dose distribution. However, other charged particles are also playing an increasing role, like neutrons. In this review article we wil summarize the data related to basic and clinical experiences related to particle beam radiation therapy.

  9. Open Cell Conducting Foams for High Synchrotron Radiation Beam Liners

    CERN Document Server

    Petracca, Stefania

    2014-01-01

    The possible use of open-cell conductive foams in high synchrotron radiation particle accelerator beam liners is considered. Available materials and modeling tools are reviewed, potential pros and cons are discussed, and preliminary conclusions are drawn.

  10. Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

    CERN Document Server

    Thurman-Keup, R; Hahn, A; Hurh, P; Lorman, E; Lundberg, C; Meyer, T; Miller, D; Pordes, S; Valishev, A

    2011-01-01

    Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measur...

  11. Beaming of particles and synchrotron radiation in relativistic magnetic reconnection

    CERN Document Server

    Kagan, Daniel; Piran, Tsvi

    2016-01-01

    Relativistic reconnection has been invoked as a mechanism for particle acceleration in numerous astrophysical systems. According to idealised analytical models reconnection produces a bulk relativistic outflow emerging from the reconnection sites (X-points). The resulting radiation is therefore highly beamed. Using two-dimensional particle-in-cell (PIC) simulations, we investigate particle and radiation beaming, finding a very different picture. Instead of having a relativistic average bulk motion with isotropic electron velocity distribution in its rest frame, we find that the bulk motion of particles in X-points is similar to their Lorentz factor gamma, and the particles are beamed within about 5/gamma. On the way from the X-point to the magnetic islands, particles turn in the magnetic field, forming a fan confined to the current sheet. Once they reach the islands they isotropise after completing a full Larmor gyration and their radiation is not strongly beamed anymore. The radiation pattern at a given freq...

  12. Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams.

    Science.gov (United States)

    Schell, Stefan; Wilkens, Jan J

    2010-10-01

    Laser plasma acceleration can potentially replace large and expensive cyclotrons or synchrotrons for radiotherapy with protons and ions. On the way toward a clinical implementation, various challenges such as the maximum obtainable energy still remain to be solved. In any case, laser accelerated particles exhibit differences compared to particles from conventional accelerators. They typically have a wide energy spread and the beam is extremely pulsed (i.e., quantized) due to the pulsed nature of the employed lasers. The energy spread leads to depth dose curves that do not show a pristine Bragg peak but a wide high dose area, making precise radiotherapy impossible without an additional energy selection system. Problems with the beam quantization include the limited repetition rate and the number of accelerated particles per laser shot. This number might be too low, which requires a high repetition rate, or it might be too high, which requires an additional fluence selection system to reduce the number of particles. Trying to use laser accelerated particles in a conventional way such as spot scanning leads to long treatment times and a high amount of secondary radiation produced when blocking unwanted particles. The authors present methods of beam delivery and treatment planning that are specifically adapted to laser accelerated particles. In general, it is not necessary to fully utilize the energy selection system to create monoenergetic beams for the whole treatment plan. Instead, within wide parts of the target volume, beams with broader energy spectra can be used to simultaneously cover multiple axially adjacent spots of a conventional dose delivery grid as applied in intensity modulated particle therapy. If one laser shot produces too many particles, they can be distributed over a wider area with the help of a scattering foil and a multileaf collimator to cover multiple lateral spot positions at the same time. These methods are called axial and lateral

  13. Efficient quasi-monoenergetic ion beams up to 18 MeV/nucleon via self-generated plasma fields in relativistic laser plasmas

    CERN Document Server

    Palaniyappan, Sasi; Gautier, Donald C; Hamilton, Christopher E; Santiago, Miguel A; Kreuzer, Christian; Shah, Rahul C; Fernandez, Juan C

    2015-01-01

    Table-top laser-plasma ion accelerators seldom achieve narrow energy spreads, and never without serious compromises in efficiency, particle yield, etc. Using massive computer simulations, we identify a self-organizing scheme that exploits persisting self-generated plasma electric (~TV/m) and magnetic (~10${}^{4}$ Tesla) fields to reduce the ion energy spread after the laser exits the plasma - separating the ion acceleration from the energy spread reduction. Consistent with the scheme, we experimentally demonstrate aluminum and carbon ion beams with narrow spectral peaks at energies up to 310 MeV (11.5 MeV/nucleon) and 220 MeV (18.3 MeV/nucleon), respectively, with high conversion efficiency (~5%, i.e., 4J out of 80J laser). This is achieved with 0.12 PW high-contrast Gaussian laser pulses irradiating planar foils with optimal thicknesses of up to 250 nm that scale with laser intensity. When increasing the focused laser intensity fourfold (by reducing the focusing optic f/number twofold), the spectral-peak ene...

  14. Beam Loss Detection at Radiation Source ELBE

    CERN Document Server

    Michel, P; Schurig, R; Langenhagen, H

    2003-01-01

    The Rossendorf superconducting Electron Linac of high Brilliance and low Emittance (ELBE) delivers an 40 MeV, 1 mA cw-beam for different applications such as bremsstrahlung production, electron channelling, free-electron lasers or secondary particle beam generation. In this energy region in case of collisions of the electron beam with the pipe nearly all beam power will be deposited into the pipe material. Therefore a reliable beam loss monitoring is essential for machine protection at ELBE. Different systems basing on photo multipliers, compton diodes and long ionization chambers were studied. The pros and cons of the different systems will be discussed. Ionization chambers based on air-isolated RF cables installed some cm away parallel to the beam line turned out to be the optimal solution. The beam shut-off threshold was adjusted to 1 μC integral charge loss during a 100 ms time interval. Due to the favourable geometry the monitor sensitivity varies less than ±50% along the beam line (di...

  15. Beam-limiting and radiation-limiting interlocks

    Energy Technology Data Exchange (ETDEWEB)

    Macek, R.J.

    1996-04-01

    This paper reviews several aspects of beam-limiting and radiation- limiting interlocks used for personnel protection at high-intensity accelerators. It is based heavily on the experience at the Los Alamos Neutron Science Center (LANSCE) where instrumentation-based protection is used extensively. Topics include the need for ``active`` protection systems, system requirements, design criteria, and means of achieving and assessing acceptable reliability. The experience with several specific devices (ion chamber-based beam loss interlock, beam current limiter interlock, and neutron radiation interlock) designed and/or deployed to these requirements and criteria is evaluated.

  16. Progress report on the neutral beam radiation hardening study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.D.; Condit, R.H.; Hoenig, C.L.; Wilcox, T.P.; Erickson, J.

    1978-10-01

    A neutral beam injector as presently conceived directly views the plasma it is sustaining. In turn the injector is exposed to the primary fusion neutrons plus secondary neutrons and gammas streaming back up the neutral beam duct. The intent of this work is to examine representative beam lines to see how performance and lifetimes could be affected by this radiation environment and to determine how unacceptable effects could be alleviated. Potential radiation induced problems addressed in this report have been limited to: (1) overheating of cryopanels and insulators, (2) gamma flux induced electrical conductivity increase of insulators, and (3) neutron and gamma fluence induced damage to insulator materials.

  17. Laser-driven beam lines for delivering intensity modulated radiation therapy with particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, K. M.; Schell, S.; Wilkens, J. J. [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 München (Germany)

    2013-07-26

    Laser-accelerated particles can provide a promising opportunity for radiation therapy of cancer. Potential advantages arise from combining a compact, cost-efficient treatment unit with the physical advantages in dose delivery of charged particle beams. We consider different dose delivery schemes and the required devices to design a possible treatment unit. The secondary radiation produced in several beam line elements remains a challenge to be addressed.

  18. Spin-polarized free electron beam interaction with radiation and superradiant spin-flip radiative emission

    Directory of Open Access Journals (Sweden)

    A. Gover

    2006-06-01

    Full Text Available The problems of spin-polarized free-electron beam interaction with electromagnetic wave at electron-spin resonance conditions in a magnetic field and of superradiant spin-flip radiative emission are analyzed in the framework of a comprehensive classical model. The spontaneous emission of spin-flip radiation from electron beams is very weak. We show that the detectivity of electron spin resonant spin-flip and combined spin-flip/cyclotron-resonance-emission radiation can be substantially enhanced by operating with ultrashort spin-polarized electron beam bunches under conditions of superradiant (coherent emission. The proposed radiative spin-state modulation and the spin-flip radiative emission schemes can be used for control and noninvasive diagnostics of polarized electron/positron beams. Such schemes are of relevance in important scattering experiments off nucleons in nuclear physics and off magnetic targets in condensed matter physics.

  19. Study on external beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Yoo, Seoung Yul; Yoo, Hyung Jun; Ji, Young Hoon; Lee, Dong Han; Lee, Dong Hoon; Choi, Mun Sik; Yoo, Dae Heon; Lee, Hyo Nam; Kim, Kyeoung Jung

    1999-04-01

    To develop the therapy technique which promote accuracy and convenience in external radiation therapy, to obtain the development of clinical treatment methods for the global competition. The contents of the R and D were 1. structure, process and outcome analysis in radiation therapy department. 2. Development of multimodality treatment in radiation therapy 3. Development of computation using networking techniques 4. Development of quality assurance (QA) system in radiation therapy 5. Development of radiotherapy tools 6. Development of intraoperative radiation therapy (IORT) tools. The results of the R and D were 1. completion of survey and analysis about Korea radiation therapy status 2. Performing QA analysis about ICR on cervix cancer 3. Trial of multicenter randomized study on lung cancers 4. Setting up inter-departmental LAN using MS NT server and Notes program 5. Development of ionization chamber and dose-rate meter for QA in linear accelerator 6. Development on optimized radiation distribution algorithm for multiple slice 7. Implementation on 3 dimensional volume surface algorithm and 8. Implementation on adaptor and cone for IORT.

  20. Power Beaming Leakage Radiation as a SETI Observable

    Science.gov (United States)

    Benford, James N.; Benford, Dominic J.

    2016-07-01

    The most observable leakage radiation from an advanced civilization may well be from the use of power beaming to transfer energy and accelerate spacecraft. Applications suggested for power beaming involve launching spacecraft to orbit, raising satellites to a higher orbit, and interplanetary concepts involving space-to-space transfers of cargo or passengers. We also quantify beam-driven launch to the outer solar system, interstellar precursors, and ultimately starships. We estimate the principal observable parameters of power beaming leakage. Extraterrestrial civilizations would know their power beams could be observed, and so could put a message on the power beam and broadcast it for our receipt at little additional energy or cost. By observing leakage from power beams we may find a message embedded on the beam. Recent observations of the anomalous star KIC 8462852 by the Allen Telescope Array (ATA) set some limits on extraterrestrial power beaming in that system. We show that most power beaming applications commensurate with those suggested for our solar system would be detectable if using the frequency range monitored by the ATA, and so the lack of detection is a meaningful, if modest, constraint on extraterrestrial power beaming in that system. Until more extensive observations are made, the limited observation time and frequency coverage are not sufficiently broad in frequency and duration to produce firm conclusions. Such beams would be visible over large interstellar distances. This implies a new approach to the SETI search: instead of focusing on narrowband beacon transmissions generated by another civilization, look for more powerful beams with much wider bandwidth. This requires a new approach for their discovery by telescopes on Earth. Further studies of power beaming applications should be performed, potentially broadening the parameter space of the observable features that we have discussed here.

  1. Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

    Science.gov (United States)

    Thurman-Keup, R.; Cheung, H. W. K.; Hahn, A.; Hurh, P.; Lorman, E.; Lundberg, C.; Meyer, T.; Miller, D.; Pordes, S.; Valishev, A.

    2011-09-01

    Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics. Work supported by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy.

  2. Note: A monoenergetic proton backlighter for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Rygg, J. R.; LePape, S.; Bachmann, B.; Khan, S. F.; Sayre, D. B. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Zylstra, A. B.; Séguin, F. H.; Gatu-Johnson, M.; Lahmann, B. J.; Petrasso, R. D.; Sio, H. W. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Craxton, R. S.; Garcia, E. M.; Kong, Y. Z.; McKenty, P. W. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Rinderknecht, H. G. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2015-11-15

    A monoenergetic, isotropic proton source suitable for proton radiography applications has been demonstrated at the National Ignition Facility (NIF). A deuterium and helium-3 gas-filled glass capsule was imploded with 39 kJ of laser energy from 24 of NIF’s 192 beams. Spectral, spatial, and temporal measurements of the 15-MeV proton product of the {sup 3}He(d,p){sup 4}He nuclear reaction reveal a bright (10{sup 10} protons/sphere), monoenergetic (ΔE/E = 4%) spectrum with a compact size (80 μm) and isotropic emission (∼13% proton fluence variation and <0.4% mean energy variation). Simultaneous measurements of products produced by the D(d,p)T and D(d,n){sup 3}He reactions also show 2 × 10{sup 10} isotropically distributed 3-MeV protons.

  3. Note: A monoenergetic proton backlighter for the National Ignition Facility

    Science.gov (United States)

    Rygg, J. R.; Zylstra, A. B.; Séguin, F. H.; LePape, S.; Bachmann, B.; Craxton, R. S.; Garcia, E. M.; Kong, Y. Z.; Gatu-Johnson, M.; Khan, S. F.; Lahmann, B. J.; McKenty, P. W.; Petrasso, R. D.; Rinderknecht, H. G.; Rosenberg, M. J.; Sayre, D. B.; Sio, H. W.

    2015-11-01

    A monoenergetic, isotropic proton source suitable for proton radiography applications has been demonstrated at the National Ignition Facility (NIF). A deuterium and helium-3 gas-filled glass capsule was imploded with 39 kJ of laser energy from 24 of NIF's 192 beams. Spectral, spatial, and temporal measurements of the 15-MeV proton product of the 3He(d,p)4He nuclear reaction reveal a bright (1010 protons/sphere), monoenergetic (ΔE/E = 4%) spectrum with a compact size (80 μm) and isotropic emission (˜13% proton fluence variation and <0.4% mean energy variation). Simultaneous measurements of products produced by the D(d,p)T and D(d,n)3He reactions also show 2 × 1010 isotropically distributed 3-MeV protons.

  4. Radiation Shielding Design for ISOL System Beam Line

    Institute of Scientific and Technical Information of China (English)

    WANG; Feng; QIN; Jiu-chang

    2013-01-01

    The beam line of the ISOL system passes through the shielding wall and connects the HI-13 tandem accelerator.Neutron produced by tandem accelerator will affect the area of BRIF through the beam line.To protect the staff in BRIF area from radiation a shielding design of the beam line is carried out.The neutron source in the vault of tandem accelerator is the H.E Faraday cup of HI-13 tandem accelerator as showed in Fig.1.The Faraday cup is consisted of 1 mm molybdenum sheet and 10 mm

  5. Whistler-mode radiation from the Spacelab 2 electron beam

    Science.gov (United States)

    Gurnett, D. A.; Kurth, W. S.; Steinberg, J. T.; Banks, P. M.; Bush, R. I.

    1986-01-01

    During the Spacelab 2 mission the Plasma Diagnostics Package (PDP) performed a fly-around of the Shuttle at distances of up to 300 meters while an electron beam was being ejected from the Shuttle. A magnetic conjunction of the Shuttle and the PDP while the electron gun was operating in a steady (DC) mode is discussed. During this conjunction, the PDP detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the beam. Ray-path calculations show that the shape of the funnel can be accounted for by whistler-mode waves propagating near the resonance cone. Because the beam and waves are propagating in the same direction, the radiation must be produced by a Landau interaction with the beam. Other types of waves generated by the beam are also described.

  6. Gravitational solutions, including radiation, for a perturbed light beam

    Energy Technology Data Exchange (ETDEWEB)

    Nackoney, R.W.

    1986-09-01

    Linearized field equations and solutions are derived for a perturbed sheet beam of light. The work is based on an exact solution of a collimated beam in the geometrical limit. The linearized field changes of the initially curved background metric can be put, with the help of the harmonic conditions, into a normal coordinate form. These six normal coordinates satisfy six linearized, inhomogeneous, field equations in three variables. Stationary solutions include divergent beams. Gravitational waves propagating opposite to the beam's flux are found to be confined to a region about the propagation axis of the beam, much as is experienced in wave guides. Radiative cases can be produced by large angle scattering of light and are discussed in terms of their effect on an ideal optical antenna. The effect is one that grows linearly with time. The growth time is prohibitively long for the most energetic systems that can be realistically considered in the foreseeable future.

  7. Optical Synchrotron Radiation Beam Imaging with a Digital Mask

    Energy Technology Data Exchange (ETDEWEB)

    Fiorito, R. B. [University of Maryland, College Park, MD (United States); Zhang, H. D. [University of Maryland, College Park, MD (United States); Corbett, W. J. [SLAC, Menlo Park, CA (United States); Fisher, A. S. [SLAC, Menlo Park, CA (United States); Mok, W. Y. [SLAC, Menlo Park, CA (United States); Tian, K. [SLAC, Menlo Park, CA (United States); Douglas, D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wilson, F. G. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, S. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Mitsuhashi, T. M. [KEK, Tsukuba (Japan); Shkvarunets, A. G. [University of Maryland, College Park, MD (United States)

    2012-11-01

    We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

  8. Optical synchrotron radiation beam imaging with a digital mask

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [Univ. of Maryland, College Park, MD (United States); Fiorito, Ralph [Univ. of Maryland, College Park, MD (United States); Corbett, Jeff [SLAC National Accelerator Lab., Menlo Park, CA (United States); Shkvarunets, Anatoly [Univ. of Maryland, College Park, MD (United States); Tian, Kai [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fisher, Alan [SLAC National Accelerator Lab., Menlo Park, CA (United States); Douglas, D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wilson, F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Mok, W. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Mitsuhashi, T. [KEK, Tsukuba (Japan)

    2016-01-01

    The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

  9. Simulation of transition radiation based beam imaging from tilted targets

    Directory of Open Access Journals (Sweden)

    L. G. Sukhikh

    2017-03-01

    Full Text Available Transverse beam profile diagnostics in linear electron accelerators is usually based on direct imaging of a beam spot via visible transition radiation. In this case the fundamental resolution limit is determined by radiation diffraction in the optical system. A method to measure beam sizes beyond the diffraction limit is to perform imaging dominated by a single-particle function (SPF, i.e. when the recorded image is dominated not by the transverse beam profile but by the image function of a point source (single electron. Knowledge of the SPF for an experimental setup allows one to extract the transverse beam size from an SPF dominated image. This paper presents an approach that allows one to calculate two-dimensional SPF dominated beam images, taking into account the target inclination angle and the depth-of-field effect. In conclusion, a simple fit function for beam size determination in the case under consideration is proposed and its applicability is tested under various conditions.

  10. Calibration of CR-39 with monoenergetic protons

    Science.gov (United States)

    Xiaojiao, Duan; Xiaofei, Lan; Zhixin, Tan; Yongsheng, Huang; Shilun, Guo; Dawei, Yang; Naiyan, Wang

    2009-10-01

    Calibration of solid state nuclear track detector CR-39 was carried out with very low-energy monoenergetic protons of 20-100 keV from a Cockcroft Walton accelerator. To reduce the beam of the proton from the accelerator, a novel method was adopted by means of a high voltage pulse generator. The irradiation time of the proton beam on each CR-39 sheet was shortened to one pulse with duration of 100 ns, so that very separated proton tracks around 104 cm-2 can be irradiated and observed and measured on the surface of the CR-39 detector after etching. The variations of track diameter with etching time as well as with proton energy response curve has been carefully calibrated for the first time in this very low energy region. The calibration shows that the optical limit for the observation of etched tracks of protons in CR-39 is about or a little lower that 20 keV, above which the proton tracks can be seen clearly and the response curve can be used to distinguish protons from the other ions and determine the energy of the protons. The extension of response curve of protons from traditionally 20 to 100 keV in CR-39 is significant in retrieving information of protons produced in the studies of nuclear physics, plasma physics, ultrahigh intensity laser physics and laser acceleration.

  11. Monte Carlo radiation transport in external beam radiotherapy

    OpenAIRE

    Çeçen, Yiğit

    2013-01-01

    The use of Monte Carlo in radiation transport is an effective way to predict absorbed dose distributions. Monte Carlo modeling has contributed to a better understanding of photon and electron transport by radiotherapy physicists. The aim of this review is to introduce Monte Carlo as a powerful radiation transport tool. In this review, photon and electron transport algorithms for Monte Carlo techniques are investigated and a clinical linear accelerator model is studied for external beam radiot...

  12. Spectral properties of Compton inverse radiation: Application of Compton beams

    CERN Document Server

    Bulyak, Eugene

    2013-01-01

    Compton inverse radiation emitted due to backscattering of laser pulses off the relativistic electrons possesses high spectral density and high energy of photons - in hard x-ray up to gamma-ray energies - because of short wavelength of laser radiation as compared with the classical electromagnetic devices such as undulators. In this report, the possibility of such radiation to monochromatization by means of collimation is studied. Two approaches have been considered for the description of the spectral-angular density of Compton radiation based on the classical field theory and on the quantum electrodynamics. As is shown, both descriptions produce similar total spectra. On the contrary, angular distribution of the radiation is different: the classical approach predicted a more narrow radiation cone. Also proposed and estimated is a method of the `electronic' monochromatization based on the electronic subtraction of the two images produced by the electron beams with slightly different energies. A `proof-of-prin...

  13. Scattered radiation from applicators in clinical electron beams.

    NARCIS (Netherlands)

    Battum, L.J. van; Zee, W. van der; Huizenga, H.

    2003-01-01

    In radiotherapy with high-energy (4-25 MeV) electron beams, scattered radiation from the electron applicator influences the dose distribution in the patient. In most currently available treatment planning systems for radiotherapy this component is not explicitly included and handled only by a slight

  14. Operator radiation exposure in cone-beam computed tomography guidance

    NARCIS (Netherlands)

    Braak, S.J.; Strijen Van, M. J L; Meijer, E.; Heesewijk Van, J. P M; Mali, W. P T M

    2016-01-01

    Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile rad

  15. A phase-space beam position monitor for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Samadi, Nazanin, E-mail: nazanin.samadi@usask.ca [University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK (Canada); Bassey, Bassey; Martinson, Mercedes [University of Saskatchewan, 116 Science Place, Saskatoon, SK (Canada); Belev, George; Dallin, Les; Jong, Mark de [Canadian Light Source, 44 Innovation Boulevard, Saskatoon, SK (Canada); Chapman, Dean [University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK (Canada)

    2015-06-25

    A system has been developed to measure the vertical position and angle of the electron beam at a single location from a synchrotron source. The system uses a monochromator tuned to the absorption edge of a contrast material and has a sensitivity comparable with other beam position monitors. The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simultaneously measure the photon beam’s position and angle, and thus infer the electron beam’s position in phase space. X-ray diffraction is commonly used to prepare monochromatic beams on X-ray beamlines usually in the form of a double-crystal monochromator. Diffraction couples the photon wavelength or energy to the incident angle on the lattice planes within the crystal. The beam from such a monochromator will contain a spread of energies due to the vertical divergence of the photon beam from the source. This range of energies can easily cover the absorption edge of a filter element such as iodine at 33.17 keV. A vertical profile measurement of the photon beam footprint with and without the filter can be used to determine the vertical centroid position and angle of the photon beam. In the measurements described here an imaging detector is used to measure these vertical profiles with an iodine filter that horizontally covers part of the monochromatic beam. The goal was to investigate the use of a combined monochromator, filter and detector as a phase-space beam position monitor. The system was tested for sensitivity to position and angle under a number of synchrotron operating conditions, such as normal operations and special operating modes where the photon beam is intentionally altered

  16. Measurement of microwave radiation from electron beam in the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, I.S.; Akimune, H. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Fukushima, M.; Ikeda, D. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Inome, Y. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Matthews, J.N. [University of Utah, Salt Lake City, UT 4112-0830 (United States); Ogio, S. [Graduate School of Science, Osaka City University, Osaka 558-8585 (Japan); Sagawa, H. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Sako, T. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Yamamoto, T., E-mail: tokonatu@konan-u.ac.jp [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan)

    2016-02-21

    We report the use of an electron light source (ELS) located at the Telescope Array Observatory in Utah, USA, to measure the isotropic microwave radiation from air showers. To simulate extensive air showers, the ELS emits an electron beam into the atmosphere and a parabola antenna system for the satellite communication is used to measure the microwave radiation from the electron beam. Based on this measurement, an upper limit on the intensity of a 12.5 GHz microwave radiation at 0.5 m from a 10{sup 18} eV air shower was estimated to be 3.96×10{sup −16} W m{sup −2} Hz{sup −1} with a 95% confidence level.

  17. Radiation Tolerance of Cryogenic Beam Loss Monitor Detectors

    CERN Document Server

    Kurfuerst, C; Bartosik, M; Dehning, B; Eisel, T; Sapinski, M; Eremin, V; Verbitskaya, E; Fabjan, C; Griesmayer, E

    2013-01-01

    At the triplet magnets, close to the interaction regions of the LHC, the current Beam Loss Monitoring system is sensitive to the particle showers resulting from the collision of the two beams. For the future, with beams of higher energy and intensity resulting in higher luminosity, distinguishing between these interaction products and possible quench-provoking beam losses from the primary proton beams will be challenging. Investigations are therefore underway to optimise the system by locating the beam loss detectors as close as possible to the superconducting coils of the triplet magnets. This means putting detectors inside the cold mass in superfluid helium at 1.9 K. Previous tests have shown that solid state diamond and silicon detectors as well as liquid helium ionisation chambers are promising candidates. This paper will address the final open question of their radiation resistance for 20 years of nominal LHC operation, by reporting on the results from high irradiation beam tests carried out at CERN in a...

  18. External Beam Radiation in Differentiated Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Salem Billan

    2016-01-01

    Full Text Available The treatment of differentiated thyroid carcinoma (DTC is surgery followed in some cases by adjuvant treatment, mostly with radioactive iodine (RAI. External beam radiotherapy (EBRT is less common and not a well-established treatment modality in DTC. The risk of recurrence depends on three major prognostic factors: extra-thyroid extension, patient’s age, and tumor with reduced iodine uptake. Increased risk for recurrence is a major factor in the decision whether to treat the patient with EBRT. Data about the use of EBRT in DTC are limited to small retrospective studies. Most series have demonstrated an increase in loco-regional control. The risk/benefit from giving EBRT requires careful patient selection. Different scoring systems have been proposed by different investigators and centers. The authors encourage clinicians treating DTC to become familiarized with those scoring systems and to use them in the management of different cases. The irradiated volume should include areas of risk for microscopic disease. Determining those areas in each case can be difficult and requires detailed knowledge of the surgery and pathological results, and also understanding of the disease-spreading pattern. Treatment with EBRT in DTC can be beneficial, and data support the use of EBRT in high-risk patients. Randomized controlled trials are needed for better confirmation of the role of EBRT.

  19. Electron Beam Diagnostics at the Radiation Source ELBE

    Science.gov (United States)

    Evtushenko, P.; Lehnert, U.; Michel, P.; Schneider, C.; Schurig, R.; Teichert, J.

    2002-12-01

    In the research center Rossendorf, the radiation source ELBE, based on a super conducting LINAC, is under construction. In the year 2001 the first accelerating module was commissioned. The electron beam parameters like emittance, bunch length, energy spread were measured. Here we present results of the measurements as well as the methods used to make the measurements. In the ELBE injector, where electron beam energy is 250 keV, the emittance was measured with the aid of a multislit device. Emittance of the accelerated beam was measured by means of quadrupole scan method and is 8 mm×mrad at 77 pC bunch charge. Electron bunch length was measured using the coherent transition radiation technique. At the maximum design bunch charge of 77 pC the RMS bunch length was measured to be 2 ps. A set of online diagnostic systems is also under development. One these include a system of stripline beam position monitors is also described here. A BPM resolution of about 10 μm was achieved using logarithmic amplifier as the core element of the BPM electronics. A system of beam loss monitors based on the RF Heliax cable working as an ionization chamber is intended to be another online diagnostic system.

  20. Radiation protection system at the RIKEN RI beam factory.

    Science.gov (United States)

    Uwamino, Y; Fujita, S; Sakamoto, H; Ito, S; Fukunishi, N; Yabutani, T; Yamano, T; Fukumura, A

    2005-01-01

    The RIKEN RI (radioactive isotope) Beam Factory is scheduled to commence operations in 2006, and its maximum energy will be 400 MeV u(-1) for ions lighter than Ar and 350 MeV u(-1) for uranium. The beam intensity will be 1 pmicroA (6 x 10(12) particles s(-1)) for any element at the goal. For the hands-on-maintenance and the rational shield thickness of the building, the beam loss must be controlled with several kinds of monitors. Three types of radiation monitors will be installed. The first one consists of a neutron dose equivalent monitor and an ionisation chamber, which are commercially available area monitors. The second one is a conventional hand-held dose equivalent monitor wherein the logarithmic signal is read by a programmable logic controller based on the radiation safety interlock system (HIS). The third one is a simple plastic scintillator called a beam loss monitor. All the monitors have threshold levels for alarm and beam stop, and HIS reads all these signals.

  1. Radiation monitoring and beam dump system of the OPAL silicon microvertex detector

    CERN Document Server

    Braibant, S

    1997-01-01

    The OPAL microvertex silicon detector radiation monitoring and beam dump system is described. This system was designed and implemented in order to measure the radiation dose received at every beam crossing and to induce a fast beam dump if the radiation dose exceeds a given threshold.

  2. Beam dumps design and local radiation protection at TERA synchrotron.

    Science.gov (United States)

    Porta, A; Campi, F; Agosteo, S

    2005-01-01

    The realisation of the National Center of Hadrontherapy was funded by the Italian Government in 2002. The Centre will be built in the area of Pavia (Italy). The synchrotron designed in the framework of this programme will accelerate protons and carbon ions up to 250 MeV and 400 MeV u(-1), respectively. Some of the main aspects which were taken into account in the design of the acceleration system are the patient's safety and the beam control. From this point of view an important role is played by the beam dumps in the synchrotron ring and upstream of the extraction system. In particular, an horizontal and a vertical beam dump will be installed in the synchrotron ring: the former will be used for lowering the beam intensity and the latter for beam abortion. The dump at the extraction will absorb the particles during the mounting and the falling ramps of the synchrotron magnetic cycle, thus extracting only the flat top of the ion spill. Beam dumps can produce intense fields of secondary radiation (neutrons, charged light-hadrons and photons) and high rates of induced activity, since they can absorb the beam completely. Usually they have to be shielded to protect the electronics during machine operation and to attenuate the radiation dose below the limits imposed by the law when the personnel access to the synchrotron hall. The part of the shielding design of the beam dumps concerning with the acceleration of protons was made using Monte Carlo simulations with the FLUKA code. Both induced activity and secondary radiation were taken into account. The shields against secondary radiation produced by carbon ions were designed, referring only to secondary neutrons, taking double-differential distributions from the literature as sources for the FLUKA simulations. The induced activity from carbon ions interactions was estimated analytically, using the data generated by the EPAX 2 code. The dose-equivalent rates from the induced radionuclides were calculated at 1 m from the

  3. Gelatin/piassava composites treated by Electron Beam Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Takinami, Patricia Yoko Inamura; Shimazaki, Kleber; Moura, Esperidiana Augusta Barretos de; Mastro, Nelida Lucia del, E-mail: patyoko@yahoo.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Colombo, Maria Aparecida [Faculdade de Tecnologia da Zona Leste (FATEC), Sao Paulo, SP (Brazil)

    2010-07-01

    Piassava (Attalea funifera Mart) fiber has been investigated as reinforcement for polymer composites with potential for practical applications. The purpose of the present work was to assess the behavior of specimens of piassava fiber and gelatin irradiated with electron beam at different doses and percentage. The piassava/gelatin specimens were made with 5 and 10% (w/w) piassava fiber, gelatin 25% (w/w), glycerin as plasticizer and acrylamide as copolymer. The samples were irradiated up to 40 kGy using an electron beam accelerator, at room temperature in presence of air. Preliminary results showed mechanical properties enhancement with the increase in radiation dose. (author)

  4. Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

    CERN Document Server

    Povoli, Marco; Bravin, Alberto; Cornelius, Iwan; Bräuer-Krisch, Elke; Fournier, Pauline; Hansen, Thor-Erik; Kok, Angela; Lerch, Michael; Monakhov, Edouard; Morse, John; Petasecca, Marco; Requardt, Herwig; Rosenfeld, Anatoly; Röhrich, Dieter; Sandaker, Heidi; Salomé, Murielle; Stugu, Bjarne

    2015-01-01

    Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any...

  5. Terahertz plasmonic laser radiating in an ultra-narrow beam

    CERN Document Server

    Wu, Chongzhao; Reno, John L; Kumar, Sushil

    2016-01-01

    Plasmonic lasers (spasers) generate coherent surface-plasmon-polaritons (SPPs) and could be realized at subwavelength dimensions in metallic cavities for applications in nanoscale optics. Plasmonic cavities are also utilized for terahertz quantum-cascade lasers (QCLs), which are the brightest available solid-state sources of terahertz radiation. A long standing challenge for spasers is their poor coupling to the far-field radiation. Unlike conventional lasers that could produce directional beams, spasers have highly divergent radiation patterns due to their subwavelength apertures. Here, we theoretically and experimentally demonstrate a new technique for implementing distributed-feedback (DFB) that is distinct from any other previously utilized DFB schemes for semiconductor lasers. The so-termed antenna-feedback scheme leads to single-mode operation in plasmonic lasers, couples the resonant SPP mode to a highly directional far-field radiation pattern, and integrates hybrid SPPs in surrounding medium into the ...

  6. Off-Axis Undulator Radiation for CLIC Drive Beam Diagnostics

    CERN Document Server

    Jeff, A; Welsch, CP

    2013-01-01

    The Compact LInear Collider (CLIC) will use a novel acceleration scheme in which energy extracted from a very intense beam of relatively low-energy electrons (the Drive Beam) is used to accelerate a lower intensity Main Beam to very high energy. The high intensity of the Drive Beam, with pulses of more than 1015 electrons, poses a challenge for conventional profile measurements such as wire scanners. Thus, new non-invasive profile measurements are being investigated. In this paper we propose the use of relatively inexpensive permanent-magnet undulators to generate off-axis visible Synchrotron Radiation from the CLIC Drive Beam. The field strength and period length of the undulator should be designed such that the on-axis undulator wavelength is in the ultra-violet. A smaller but still useable amount of visible light is then generated in a hollow cone. This light can be reflected out of the beam pipe by a ring-shaped mirror placed downstream and imaged on a camera. In this contribution, results of SRW and ZEMA...

  7. Shielding and Radiation Protection in Ion Beam Therapy Facilities

    Science.gov (United States)

    Wroe, Andrew J.; Rightnar, Steven

    Radiation protection is a key aspect of any radiotherapy (RT) department and is made even more complex in ion beam therapy (IBT) by the large facility size, secondary particle spectra and intricate installation of these centers. In IBT, large and complex radiation producing devices are used and made available to the public for treatment. It is thus the responsibility of the facility to put in place measures to protect not only the patient but also the general public, occupationally and nonoccupationally exposed personnel working within the facility, and electronics installed within the department to ensure maximum safety while delivering maximum up-time.

  8. Improvement of electron beam shape control in radiation processing

    Science.gov (United States)

    Strasser, A.; Fang, R.; Kuntz, F.

    1994-05-01

    The development of radiation processing using electron accelerators requires good control of the treatment parameters to improve the dosimetry quality. Especially, the analysis of the shape of the scanned electron beam that interacts with the product, is of prime necessity. A Multiwire Beam Shape Analyser (MBSA) has been developed by the AERIAL Laboratory in order to insure good monitoring of the scanning length and uniformity. This device consists of an aluminum beam-stop covered with a mesh of individually insulated stainless steel wires, placed under the scanning cone. The current generated by the impact of the electron beam on each wire is converted into voltage. After pulse shaping and multiplexing of the different channels, the beam profile can be displayed on an oscilloscope or on a PC screen. A prototype is now operating on an experimental irradiation plant based on a 2.5 MeV /300 W Van de Graaff electron accelerator. It allows almost continuous visualization of the beam profile (between two conveyor passes) and its response was compared to classical film dosimeters (Gafchromic, FWT 60.00). Considering FWHM and homogeneous treatment regions of the profiles, MBSA and the dosimeters give similar responses and variations remain lower than ± 12%. The acquisition of an electrical signal corresponding to the beam profile in air constitutes the original aspect of the MBSA and is in keeping with the general pattern of continuous control and automation of the irradiation processes. Hereafter, much work has to be done to adapt this device to an industrial use (higher energy, high power electron beams, non-destructive measurements…).

  9. Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm

    Science.gov (United States)

    Famulari, Gabriel; Pater, Piotr; Enger, Shirin A.

    2017-07-01

    The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy (\\bar{y}D ) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The \\bar{y}D values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length (\\bar{l} ), the \\bar{y}D calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of \\bar{y}D values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.

  10. Initial results from a multiple monoenergetic gamma radiography system for nuclear security

    Science.gov (United States)

    O'Day, Buckley E.; Hartwig, Zachary S.; Lanza, Richard C.; Danagoulian, Areg

    2016-10-01

    The detection of assembled nuclear devices and concealed special nuclear materials (SNM) such as plutonium or uranium in commercial cargo traffic is a major challenge in mitigating the threat of nuclear terrorism. Currently available radiographic and active interrogation systems use ∼1-10 MeV bremsstrahlung photon beams. Although simple to build and operate, bremsstrahlung-based systems deliver high radiation doses to the cargo and to potential stowaways. To eliminate problematic issues of high dose, we are developing a novel technique known as multiple monoenergetic gamma radiography (MMGR). MMGR uses ion-induced nuclear reactions to produce two monoenergetic gammas for dual-energy radiography. This allows us to image the areal density and effective atomic number (Zeff) of scanned cargo. We present initial results from the proof-of-concept experiment, which was conducted at the MIT Bates Research and Engineering Center. The purpose of the experiment was to assess the capabilities of MMGR to measure areal density and Zeff of container cargo mockups. The experiment used a 3.0 MeV radiofrequency quadrupole accelerator to create sources of 4.44 MeV and 15.11 MeV gammas from the 11B(d,nγ)12C reaction in a thick natural boron target; the gammas are detected by an array of NaI(Tl) detectors after transmission through cargo mockups . The measured fluxes of transmitted 4.44 MeV and 15.11 MeV gammas were used to assess the areal density and Zeff. Initial results show that MMGR is capable of discriminating the presence of high-Z materials concealed in up to 30 cm of iron shielding from low- and mid-Z materials present in the cargo mockup.

  11. High-quality electron beam generation and bright betatron radiation from a cascaded laser wakefield accelerator (Conference Presentation)

    Science.gov (United States)

    Liu, Jiansheng; Wang, Wentao; Li, Wentao; Qi, Rong; Zhang, Zhijun; Yu, Changhai; Wang, Cheng; Liu, Jiaqi; Qing, Zhiyong; Ming, Fang; Xu, Yi; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2017-05-01

    One of the major goals of developing laser wakefiled accelerators (LWFAs) is to produce compact high-energy electron beam (e-beam) sources, which are expected to be applied in developing compact x-ray free-electron lasers and monoenergetic gamma-ray sources. Although LWFAs have been demonstrated to generate multi-GeV e-beams, to date they are still failed to produce high quality e beams with several essential properties (narrow energy spread, small transverse emittance and high beam charge) achieved simultaneously. Here we report on the demonstration of a high-quality cascaded LWFA experimentally via manipulating electron injection, seeding in different periods of the wakefield, as well as controlling energy chirp for the compression of energy spread. The cascaded LWFA was powered by a 1-Hz 200-TW femtosecond laser facility at SIOM. High-brightness e beams with peak energies in the range of 200-600 MeV, 0.4-1.2% rms energy spread, 10-80 pC charge, and 0.2 mrad rms divergence are experimentally obtained. Unprecedentedly high 6-dimensional (6-D) brightness B6D,n in units of A/m2/0.1% was estimated at the level of 1015-16, which is very close to the typical brightness of e beams from state-of-the-art linac drivers and several-fold higher than those of previously reported LWFAs. Furthermore, we propose a scheme to minimize the energy spread of an e beam in a cascaded LWFA to the one-thousandth-level by inserting a stage to compress its longitudinal spatial distribution via velocity bunching. In this scheme, three-segment plasma stages are designed for electron injection, e-beam length compression, and e-beam acceleration, respectively. A one-dimensional theory and two-dimensional particle-in-cell simulations have demonstrated this scheme and an e beam with 0.2% rms energy spread and low transverse emittance could be generated without loss of charge. Based on the high-quality e beams generated in the LWFA, we have experimentally realized a new scheme to enhance the

  12. Successful beam tests for ALICE Transition Radiation Detector

    CERN Multimedia

    2002-01-01

    Another round of beam tests of prototypes for the Transition Radiation Detector (TRD) for ALICE has been completed and there are already some good results. Mass production of the components of the detector will start early next year.   Top view of the setup for the Transition Radiation Detector prototype tests at CERN.On the left, can be seen the full-scale TRD prototype together with four smaller versions. These are busy days for the TRD (Transition Radiation Detector) team of ALICE. Twenty people - mainly from Germany, but also from Russia and Japan - were working hard during the beam tests this autumn at CERN to assess the performance of their detector prototypes. Analysis of the data shows that the TRD can achieve the desired physics goal even for the highest conceivable multiplicities in lead-lead collisions at the LHC. In its final configuration in the ALICE experiment, the TRD will greatly help in identifying high-momentum electrons, which are 'needles in a haystack' that consists mostly of...

  13. Wireless Links in the Radiative Near Field via Bessel Beams

    Science.gov (United States)

    Heebl, Jason D.; Ettorre, Mauro; Grbic, Anthony

    2016-09-01

    The generation of propagating Bessel beams is typically limited to optical frequencies with bulky experimental setups. Recent works have demonstrated Bessel-beam generation at microwave and millimeter-wave frequencies utilizing low-profile, planar, leaky-wave antennas. These studies have assumed a single leaky mode in the antenna. In this work, the rigorous analysis of a planar Bessel-beam launcher supporting multiple modes is presented. By employing the mode-matching technique, a complete electromagnetic solution of the structure, its supported modes, and radiated fields is obtained. Additionally, a coupled system of two planar Bessel launchers is analyzed, and it is shown that the system can both transmit and receive Bessel beams. The energy-transfer characteristics of the coupled system are analyzed and discussed. An analysis of the coupled system's even and odd modes of operation show that efficient power transfer is possible, and that an odd mode is preferred since it yields higher field confinement and power-transfer efficiency.

  14. Terahertz radiation emission from plasma beat-wave interactions with a relativistic electron beam

    Science.gov (United States)

    Gupta, D. N.; Kulagin, V. V.; Suk, H.

    2017-10-01

    We present a mechanism to generate terahertz radiation from laser-driven plasma beat-wave interacting with an electron beam. The theory of the energy transfer between the plasma beat-wave and terahertz radiation is elaborated through nonlinear coupling in the presence of a negative-energy relativistic electron beam. An expression of terahertz radiation field is obtained to find out the efficiency of the process. Our results show that the efficiency of terahertz radiation emission is strongly sensitive to the electron beam energy. Emitted field strength of the terahertz radiation is calculated as a function of electron beam velocity.

  15. Laser radiation pressure slowing of a molecular beam

    CERN Document Server

    Barry, J F; Norrgard, E B; DeMille, D

    2011-01-01

    There is substantial interest in producing samples of ultracold molecules for possible applications in quantum computation, quantum simulation of condensed matter systems, precision measurements, controlled chemistry, and high precision spectroscopy. A crucial step to obtaining large samples of ultracold, trapped molecules is developing a means to bridge the gap between typical molecular source velocities (~150-600 m/s) and velocities for which trap loading or confinement is possible (~5-20 m/s). Here we show deceleration of a beam of neutral strontium monofluoride (SrF) molecules using radiative force. Under certain conditions, the deceleration results in a substantial flux of molecules with velocities <50 m/s. The observed slowing, from ~140 m/s, corresponds to scattering ~10000 photons. We also observe longitudinal velocity compression under different conditions. Combined with molecular laser cooling techniques, this lays the groundwork to create slow and cold molecular beams suitable for trap loading.

  16. Quantum radiation reaction in laser-electron-beam collisions.

    Science.gov (United States)

    Blackburn, T G; Ridgers, C P; Kirk, J G; Bell, A R

    2014-01-10

    It is possible using current high-intensity laser facilities to reach the quantum radiation reaction regime for energetic electrons. An experiment using a wakefield accelerator to drive GeV electrons into a counterpropagating laser pulse would demonstrate the increase in the yield of high-energy photons caused by the stochastic nature of quantum synchrotron emission: we show that a beam of 10(9) 1 GeV electrons colliding with a 30 fs laser pulse of intensity 10(22)  W cm(-2) will emit 6300 photons with energy greater than 700 MeV, 60× the number predicted by classical theory.

  17. OPTIMIZATION OF PALLIATIVE EXTERNAL BEAM RADIATION THERAPY FOR BLADDER CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2014-08-01

    Full Text Available Purpose: To improve the efficacy of palliative radiation therapy for patients with bladder cancer (BC.Materials and Methods: In the years 1990−2010, 90 patients with BC were treated with palliative external beam radiation therapy (EBRT using three regimens: conventional fractionation in group 1 (n = 37, hypofractionation in group 2 (n = 22 and accelerated dynamic fractionation in group 3 (n = 31.Results: The immediate efficacy of EBRT was evaluated taking into account rapid relief of local symptoms of disease. In group 1, a clinically significant response (hematuria relief was achieved in 63,0 % cases, in group 2 — in 62,5 %, in group 3 — in 91,7 % cases. The 10-year follow-up showed that in group 1, the median survival was 21,8 ± 3,3 months; in groups 2 and 3, the median survival was 27,0 ± 7,8 and 32,6 ± 9,8 months, respectively. In group 2, an increase in the rate of acute radiation reactions was noted, whereas in group 3, palliative EBRT did not produce higher rates and severity of acute radiation reactions and complications.Conclusion: Accelerated dynamic fractionation was found to shorten treatment times and to improve outcomes and quality of life for incurable patients with BC.

  18. OPTIMIZATION OF PALLIATIVE EXTERNAL BEAM RADIATION THERAPY FOR BLADDER CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2012-01-01

    Full Text Available Purpose: To improve the efficacy of palliative radiation therapy for patients with bladder cancer (BC.Materials and Methods: In the years 1990−2010, 90 patients with BC were treated with palliative external beam radiation therapy (EBRT using three regimens: conventional fractionation in group 1 (n = 37, hypofractionation in group 2 (n = 22 and accelerated dynamic fractionation in group 3 (n = 31.Results: The immediate efficacy of EBRT was evaluated taking into account rapid relief of local symptoms of disease. In group 1, a clinically significant response (hematuria relief was achieved in 63,0 % cases, in group 2 — in 62,5 %, in group 3 — in 91,7 % cases. The 10-year follow-up showed that in group 1, the median survival was 21,8 ± 3,3 months; in groups 2 and 3, the median survival was 27,0 ± 7,8 and 32,6 ± 9,8 months, respectively. In group 2, an increase in the rate of acute radiation reactions was noted, whereas in group 3, palliative EBRT did not produce higher rates and severity of acute radiation reactions and complications.Conclusion: Accelerated dynamic fractionation was found to shorten treatment times and to improve outcomes and quality of life for incurable patients with BC.

  19. Surface dose with grids in electron beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, K.-H.; Huang, C.-Y.; Lin, J.-P.; Chu, T.-C. E-mail: tcchu@mx.nthu.edu.tw

    2002-03-01

    This investigation attempts to solve the problem of the lack of skin-sparing effect in electron radiation therapy and to increase the tolerance of skin to radiation using the grid technique. Electron grid therapy involves the mounting of a Cerrobend grid in the electron cone. Film dosimetry was employed to measure the relative surface dose and the percentage depth dose profile of electron grid portals. Various grid hole diameters (d=0.45, 1.0, 1.5 cm) and grid hole spacings (s=0.4, 0.2 cm) were considered for electron beams from 6 to 14 MeV. Experimental results indicate that the electron grid technique can reduce the relative surface dose in electron radiation therapy. Degradations of the relative surface dose depend on the percentage of open area in the grid portal. A proper grid design allows the surface dose to be reduced and the range of nonhomogeneous doses to be limited to a depth at which the target volume can receive a homogeneous dose. The grid technique can lower the surface dose in electron radiation therapy.

  20. Radiation Exposure of Abdominal Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sailer, Anna M., E-mail: anni.sailer@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands); Schurink, Geert Willem H., E-mail: gwh.schurink@mumc.nl [Maastricht University Medical Centre, Department of Surgery (Netherlands); Wildberger, Joachim E., E-mail: j.wildberger@mumc.nl; Graaf, Rick de, E-mail: r.de.graaf@mumc.nl; Zwam, Willem H. van, E-mail: w.van.zwam@mumc.nl; Haan, Michiel W. de, E-mail: m.de.haan@mumc.nl; Kemerink, Gerrit J., E-mail: gerrit.kemerink@mumc.nl; Jeukens, Cécile R. L. P. N., E-mail: cecile.jeukens@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands)

    2015-02-15

    PurposeTo evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).MethodsThis prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.ResultsMean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.ConclusionsMean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

  1. Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

    Science.gov (United States)

    Povoli, M.; Alagoz, E.; Bravin, A.; Cornelius, I.; Bräuer-Krisch, E.; Fournier, P.; Hansen, T. E.; Kok, A.; Lerch, M.; Monakhov, E.; Morse, J.; Petasecca, M.; Requardt, H.; Rosenfeld, A. B.; Röhrich, D.; Sandaker, H.; Salomé, M.; Stugu, B.

    2015-11-01

    Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.

  2. Status of the OPAL microvertex detector and new radiation monitoring and beam dump system

    Science.gov (United States)

    Jong, Sijbrand de

    1998-11-01

    The status of the OPAL Phase III microvertex detector is discussed briefly. This is followed by a more detailed description of the OPAL microvertex detector radiation monitoring and beam dump system. This system measures AC currents induced by radiation on each passing of the beams in silicon diodes mounted close to the microvertex detector front-end electronics. Examples are shown for incidents leading to a beam dump trigger. The integrated radiation dose is also discussed.

  3. Neutrons production during the interaction of monoenergetic electrons with a thin tungsten target; Produccion de neutrones durante la interaccion de electrones monoenergeticos con un blanco delgado de tungsteno

    Energy Technology Data Exchange (ETDEWEB)

    Soto B, T. G.; Medina C, D. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Programa de Doctorado en Ciencias Basicas, 98068 Zacatecas, Zac. (Mexico); Baltazar R, A. [Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, Programa de Doctorado en Ingenieria y Tecnologia Aplicada, 98068 Zacatecas, Zac. (Mexico); Vega C, H. R., E-mail: tzinnia.soto@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2016-10-15

    When a linear accelerator for radiotherapy operates with acceleration voltages higher than 8 MV, neutrons are produced, as secondary radiation which deposits an undesirable and undesirable dose in the patient. Depending on the type of tumor, its location in the body and the characteristics of the patient, the cancer treatment with a Linac is performed with photon or electron beams, which produce neutrons through reactions (γ, n) and (e, e n) respectively. Because the effective section for the neutrons production by reactions (γ, n) is approximately two orders of magnitude larger than the effective section of the reactions (e, e n), studies on the effects of this secondary radiation have focused on photo neutrons. en a Linac operates with electron beams, the beam coming out of the magnetic deflector is impinged on the dispersion lamella in order to cause quasi-elastic interactions and to expand the spatial distribution of the electrons; the objective of this work is to determine the characteristics of the photons and neutrons that occur when a mono-energetic electron beam of 2 mm in diameter (pencil beam) is made to impinge on a tungsten lamella of 1 cm in diameter and 0.5 mm of thickness. The study was done using Monte Carlo methods with code MCNP6 for electron beams of 8, 10, 12, 15 and 18 MeV. The spectra of photons and neutrons were estimated in 4 point detectors placed at different equidistant points from the center of the lamella. (Author)

  4. Radiative damping and electron beam dynamics in plasma-based accelerators.

    Science.gov (United States)

    Michel, P; Schroeder, C B; Shadwick, B A; Esarey, E; Leemans, W P

    2006-08-01

    The effects of radiation reaction on electron beam dynamics are studied in the context of plasma-based accelerators. Electrons accelerated in a plasma channel undergo transverse betatron oscillations due to strong focusing forces. These oscillations lead to emission by the electrons of synchrotron radiation, with a corresponding energy loss that affects the beam properties. An analytical model for the single particle orbits and beam moments including the classical radiation reaction force is derived and compared to the results of a particle transport code. Since the betatron amplitude depends on the initial transverse position of the electron, the resulting radiation can increase the relative energy spread of the beam to significant levels (e.g., several percent). This effect can be diminished by matching the beam into the channel, which could require micron sized beam radii for typical values of the beam emittance and plasma density.

  5. Radiative damping and electron beam dynamics in plasma-based accelerators

    Science.gov (United States)

    Michel, P.; Schroeder, C. B.; Shadwick, B. A.; Esarey, E.; Leemans, W. P.

    2006-08-01

    The effects of radiation reaction on electron beam dynamics are studied in the context of plasma-based accelerators. Electrons accelerated in a plasma channel undergo transverse betatron oscillations due to strong focusing forces. These oscillations lead to emission by the electrons of synchrotron radiation, with a corresponding energy loss that affects the beam properties. An analytical model for the single particle orbits and beam moments including the classical radiation reaction force is derived and compared to the results of a particle transport code. Since the betatron amplitude depends on the initial transverse position of the electron, the resulting radiation can increase the relative energy spread of the beam to significant levels (e.g., several percent). This effect can be diminished by matching the beam into the channel, which could require micron sized beam radii for typical values of the beam emittance and plasma density.

  6. Modeling the radiation of ultrasonic phased-array transducers with Gaussian beams.

    Science.gov (United States)

    Huang, Ruiju; Schmerr, Lester W; Sedov, Alexander

    2008-12-01

    A new transducer beam model, called a multi-Gaussian array beam model, is developed to simulate the wave fields radiated by ultrasonic phased-array transducers. This new model overcomes the restrictions on using ordinary multi-Gaussian beam models developed for large single-element transducers in phased-array applications. It is demonstrated that this new beam model can effectively model the steered and focused beams of a linear phased-array transducer.

  7. Radiation sterilization of fluoroquinolones in solid state: Investigation of effect of gamma radiation and electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Babita K., E-mail: singhbab2001@rediffmail.co [Department of Chemistry, RTM Nagpur University Campus, Amravati Road, Nagpur 440033 (India); Central Forensic Science Laboratory, Ramanthapur, Hyderabad 500013 (India); Parwate, Dilip V. [Department of Chemistry, RTM Nagpur University Campus, Amravati Road, Nagpur 440033 (India); Dassarma, Indrani B. [Jhulelal Institute of Technology, Nagpur (India); Shukla, Sudhir K. [Central Forensic Science Laboratory, Ramanthapur, Hyderabad 500013 (India)

    2010-09-15

    The effect of gamma radiation from {sup 60}Co source and 2 MeV electron beam was studied on two fluoroquinolone antibiotics viz norfloxacin and gatifloxacin in the solid state. The changes in reflectance spectrum, yellowness index, vibrational characteristics, thermal behavior, UV spectrum, chemical potency (HPLC) and microbiological potency were investigated. ESR measurement gave the number of free radical species formed and their population. The nature of final radiolytic impurities was assessed by studying the HPLC impurity profile. Both norfloxacin and gatifloxacin were observed to be radiation resistant, and did not show significant changes in their physico-chemical properties. They could be radiation sterilized at a dose of 25 kGy.

  8. Polarizing Grids, Their Assemblies and Beams of Radiation

    CERN Document Server

    Houde, M; Carlstrom, J E; Lamb, J W; Schleuning, D A; Woody, D P; Houde, Martin; Akeson, Rachel L.; Carlstrom, John E.; Lamb, James W.; Schleuning, David A.; Woody, David P.

    2001-01-01

    This article gives an analysis of the behavior of polarizing grids and reflecting polarizers by solving Maxwell's equations, for arbitrary angles of incidence and grid rotation, for cases where the excitation is provided by an incident plane wave or a beam of radiation. The scattering and impedance matrix representations are derived and used to solve more complicated configurations of grid assemblies. The results are also compared with data obtained in the calibration of reflecting polarizers at the Owens Valley Radio Observatory (OVRO). From this analysis, we propose a method for choosing the optimum grid parameters (wire radius and spacing). We also provide a study of the effects of two types of errors (in wire separation and radius size) that can be introduced in the fabrication of a grid.

  9. Optical substrate materials for synchrotron radiation beam lines

    Science.gov (United States)

    Howells, Malcolm R.; Paquin, Roger A.

    1997-09-01

    We consider the materials choices available for making optical substrates for synchrotron radiation beam lines. We find that currently the optical surfaces can only be polished to the required finish in fused silica and other glasses, silicon, CVD silicon carbide, electroless nickel and 17-4 PH stainless steel. Substrates must therefore be made of one of these materials or of a metal that can be coated with electroless nickel. In the context of material choices for mirrors we explore the issues of dimensional stability, polishing, bending, cooling, and manufacturing strategy. We conclude that metals are best from an engineering and cost standpoint while the ceramics are best from a polishing standpoint. We then give discussions of specific materials as follows: silicon carbide, silicon, electroless nickel, GlidcopTM, aluminum, precipitation- hardening stainless steel, mild steel, invar and superinvar. Finally we summarize conclusions and propose ideas for further research.

  10. Edge radiation and its potential to electron beam diagnostics at HiSOR

    CERN Document Server

    Smolyakov, N; Hiraya, A

    2000-01-01

    The visible edge radiation generated by a relativistic electron beam at fringe fields of bending magnets in storage rings differs significantly from the well-known standard synchrotron radiation. An intensive peak appears in the electromagnetic radiation angular distribution. Its intensity exceeds considerably the intensity of synchrotron radiation. In addition, the radiation generated at two adjacent edges of bending magnets produces an interference pattern. The real electron beam parameters (its transversal sizes and angular spread) have effect on the radiation intensity distribution. It is possible to find the electron beam parameters from the experimentally measured edge radiation distribution. Such electron beam diagnostics as applied to HiSOR storage ring (Hiroshima, Japan) is discussed in the present paper.

  11. Ion beam induced luminescence: Relevance to radiation induced bystander effects

    Science.gov (United States)

    Ahmad, S. B.; McNeill, F. E.; Byun, S. H.; Prestwich, W. V.; Seymour, C.; Mothersill, C. E.

    2012-10-01

    The aim of this work is quantify the light emitted as a result of charged particle interaction in materials which may be of relevance to radiation induced "bystander effects" studies. We have developed a system which employs single photon counting to measure the light emitted from samples irradiated under vacuum by a charged particle beam. The system uses a fast photomultiplier tube with a peak cathode response at 420 nm. It has been tested in a proof-of-principle experiment using polystyrene targets. Light output, as a result of irradiation, was measured. The luminescence yield appears to have a non-linear behavior with the incident ion fluence: it rises exponentially to an asymptotic value. The target was irradiated with beam energies varying from 1 to 2 MeV and showed saturation at or before an incident fluence rate of 3 × 1013 H+/cm2 s. The average saturation value for the photon output was found to be 40 × 106 cps. Some measurements were performed using filters to study the emission at specific wavelengths. In the case of filtered light measurements, the photon output was found to saturate at 28 × 103, 10 × 106, and 35 × 106 cps for wavelengths of 280 ± 5 nm, 320 ± 5 nm and 340 ± 5 nm respectively. The light output reaches a maximum value because of damage induced in the polymer. Our measurements indicate a "damage cross section" of the order of 10-14 cm2. The average radiant intensity was found to increase at wavelengths of 280 and 320 nm when the proton energy was increased. This was not found to occur at 340 nm. In conclusion, the light emission at specific wavelengths was found to depend upon the incident proton fluence and the proton energy. The wavelengths of the emitted light measured in this study have significance for the understanding of radiation induced bystander effects.

  12. Single Gain Radiation Tolerant LHC Beam Loss Acquisition Card

    CERN Document Server

    Effinger, E; Emery, J; Ferioli, G; Zamantzas, C

    2008-01-01

    The beam loss monitoring system is one of the most critical elements for the protection of the LHC. It must prevent the super conducting magnets from quenches and the machine components from damages, caused by beam losses. Ionization chambers and secondary emission based detectors are used at several locations around the ring. The sensors are producing a signal current, which is related to the losses. This current will be measured by a tunnel card, which acquires, digitizes and transmits the data via an optical link to the surface electronic. The usage of the system, for protection and tuning of the LHC and the scale of the LHC, imposed exceptional specifications of the dynamic range and radiation tolerance. The input dynamic allows measurements between 10pA and 1mA and its protected to high pulse of 1.5kV and its corresponding current. To cover this range, a current to frequency converter in combination with an ADC is used. The integrator output voltage is measured with an ADC to improve the resolution. The ...

  13. Characteristic, parametric, and diffracted transition X-ray radiation for observation of accelerated particle beam profile

    Science.gov (United States)

    Chaikovska, I.; Chehab, R.; Artru, X.; Shchagin, A. V.

    2017-07-01

    The applicability of X-ray radiation for the observation of accelerated particle beam profiles is studied. Three types of quasi-monochromatic X-ray radiation excited by the particles in crystals are considered: characteristic X-ray radiation, parametric X-ray radiation, diffracted transition X-ray radiation. Radiation is collected at the right angle to the particle beam direction. It is show that the most intensive differential yield of X-ray radiation from Si crystal can be provided by characteristic radiation at incident electron energies up to tens MeV, by parametric radiation at incident electron energies from tens to hundreds MeV, by diffracted transition X-ray radiation at GeV and multi-GeV electron energies. Therefore these kinds of radiation are proposed for application to beam profile observation in the corresponding energy ranges of incident electrons. Some elements of X-ray optics for observation of the beam profile are discussed. The application of the DTR as a source of powerful tunable monochromatic linearly polarized X-ray beam excited by a multi-GeV electron beam on the crystal surface is proposed.

  14. Utilizing ion-beam secondary radiation for experiments on space radiation effects

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Hiroshi; Suzuki, Masao; Fujitaka, Kazunobu [National Inst. of Radiological Sciences, Chiba (Japan)

    1999-12-01

    For the purpose to make a space radiation field at the ground field, the Biology room of Heavy Ion Medical Accelerator in Chiba, National Institute of Radiological Sciences (NIRS-HIMAC) was used. Heavy ion species used in the room was mostly C and occasionally, He, Ne, Si, Ar and Fe. The secondary radiation including albed neutrons came from materials of profile monitor, Lucite filter, beam target and beam dumper of the heavy ion beam along the central line of the room to a CO{sub 2}-incubator placed at the corner of the room. Accumulated absorbed dose in the incubator was continuously measured for 223 days (5344 hr) with a Si-semiconductor detector (Siemens Plc.) set behind the plastic bottle containing the cell culture medium. The total dose was corrected by the thermoluminescent dosemeter of Mg{sub 2}SiO{sub 4} :Tb (TLD-MSO, Kasei Optonics), whose 4 chips were packed in a case of tissue equivalent resin Tough-water phantom (Kyoto Kagaku) and the package was also placed in the incubator. It was found that the field designed in NIRS-HIMAC could be used for the purpose. The dominant LET range in the incubator was assumed to be <10 keV/{mu}m and the quality factor, about 1. (K.H.)

  15. Beam Energy Considerations for Gold Nano-Particle Enhanced Radiation Treatment

    CERN Document Server

    Heuvel, F Van den; Nuyts, S

    2009-01-01

    Purpose: A novel approach using nano technology enhanced radiation modalities is investigated. The proposed methodology uses antibodies labeled with organically inert metals with a high atomic number. Irradiation using photons with energies in the kilo--electron volt (keV) range show an increase in dose due to a combination of an increase in photo-electric interactions and a pronounced generation of Auger and/or Coster-Kronig (A-CK) electrons. Methods: The dependency of the dose deposition on various factors is investigated using Monte Carlo simulation models. The factors investigated include: agent concentration, spectral dependency looking at mono--energetic sources as well as classical bremsstrahlung sources. The optimization of the energy spectrum is performed in terms of physical dose enhancement as well as the dose deposited by Auger and/or Coster-Kronig electrons and their biological effectiveness. Results: A quasi-linear dependency on concentration and an exponential decrease within the target medium ...

  16. Monoenergetic electron parameters in a spheroid bubble model

    Institute of Scientific and Technical Information of China (English)

    H.Sattarian; Sh.Rahmatallahpur; T.Tohidi

    2013-01-01

    A reliable analytical expression for the potential of plasma waves with phase velocities near the speed of light is derived.The presented spheroid cavity model is more consistent than the previous spherical and ellipsoidal models and it explains the mono-energetic electron trajectory more accurately,especially at the relativistic region.The maximum energy of electrons is calculated and it is shown that the maximum energy of the spheroid model is less than that of the spherical model.The electron energy spectrum is also calculated and it is found that the energy distribution ratio of electrons △E/E for the spheroid model under the conditions reported here is half that of the spherical model and it is in good agreement with the experimental value in the same conditions.As a result,the quasi-mono-energetic electron output beam interacting with the laser plasma can be more appropriately described with this model.

  17. Generation of linearly polarized resonant transition radiation X-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Yajima, Kazuaki; Awata, Takaaki; Ikeda, Mitsuharu; Ikeda, Kenichi; Yogo, Akifumi; Itoh, Akio; Imanishi, Nobutsugu [Kyoto Univ. (Japan). Dept. of Nuclear Engineering

    2000-03-01

    We have proposed a method to generate almost linearly polarized resonant transition radiation X rays by using a rectangular slit placed on an electron beam axis. Our calculation predicted that the linearity is 93.5% for the resonant transition radiation X-ray beam extracted through a slit of 0.5 mrad long and 0.2 mrad wide in case of 1-GeV electron beam irradiating a 7.5-{mu}m thick Kapton foil stack. (author)

  18. STUDY OF THE BEAM INDUCED RADIATION IN THE CMS DETECTOR AT THE LARGE HADRON COLLIDER

    CERN Document Server

    Singh, Amandeep P; Mokhov, Nikolai; Beri, Suman Bala

    2009-01-01

    point, are most vulnerable to beam-induced radiation. We have recently carried out extensive monte carlo simulation studies using MARS program to estimate particle fluxes and radiation dose in the CMS silicon pixel and strip trackers from proton-proton collisions at $\\sqrt s $=14 TeV and from machine induced background such as beam-gas interactions and beam-halo. We will present results on radiation dose, particle fluxes and spectra from these studies and discuss implications for radiation damage and performance of the CMS silicon tracker detec...

  19. Generation of high-power electromagnetic radiation by a beam-driven plasma antenna

    Science.gov (United States)

    Annenkov, V. V.; Volchok, E. P.; Timofeev, I. V.

    2016-04-01

    In this paper we study how efficiently electromagnetic radiation can be generated by a relativistic electron beam with a gigawatt power level during its injection into a thin magnetized plasma. It is shown that, if the transverse beam and plasma size is compared with the radiation wavelength and the plasma density is modulated along the magnetic field, such a beam-plasma system can radiate electromagnetic waves via the antenna mechanism. We propose a theoretical model describing generation of electromagnetic waves by this plasma antenna and calculate its main radiation characteristics. In the two-dimensional case theoretical predictions on the radiation efficiency are shown to be confirmed by the results of particle-in-cell simulations, and the three-dimensional variant of this theory is used to estimate the peak power of sub-terahertz radiation that can be achieved in beam-plasma experiments in mirror traps.

  20. The Evolution of External Beam Radiation Therapy (EBRT) from a Technological Perspective.

    Science.gov (United States)

    Detorie, Nicholas

    2008-03-01

    Since the discovery of x-rays by Roentgen in 1895 ionizing radiations have been used as a treatment for cancer. Such treatments have been based on either implantation of radioactive materials at the site of disease or by aiming external radiation beams at the diseased site. This later method is referred to as teletherapy because the beams originate from a location outside of the body distant from the disease site itself. A brief review of the basic radiation biology will be given to illustrate the rationale for therapeutic use of ionizing radiations and the effects of beam energy and beam type- particulate or photon. The remainder of the presentation will focus on the technological teletherapy developments supported by the required physical properties of the beams and their associated characteristics that make them suitable for patient treatments. Chronological highlights will include the following sources or devices: superficial x-rays, orthovaltage x-rays, megavoltage x-rays and Cobalt 60 photons, electron beams, neutron beams, negative pi mesons, protons, and heavy ions. The presentation will illustrate how the physical beam properties have been incorporated into modern radiation treatment devices, many of which are equipped with radiation imaging capability. Such devices include: linacs equipped with multileaf collimators for beam shaping and intensity modulation, the Gamma Knife for precise and accurate irradiation of brain tumors or arterial-venous malformations (AVM), the robotic arm based Cyber Knife, and the Helical Tomotherapy unit.

  1. The INFN Micro-Si experiment: A silicon microdosimeter for assessing radiation quality of hadrontherapy beams

    Science.gov (United States)

    Agosteo, S.; Dal Corso, F.; Fazzi, A.; Gonella, F.; Introini, M. V.; Lippi, I.; Lorenzoli, M.; Pegoraro, M.; Pola, A.; Varoli, V.; Zotto, P.

    2013-07-01

    The MICRO-SI experiment, funded by INFN from 2008 up to 2010, aimed at developing a silicon microdosimeter capable of responding to neutrons and to hadron-therapy beams down to a few keV μm-1. The main goals which were achieved in the framework of this experiment are described in details. The detector, designed and fabricated by exploiting the monolithic telescope technology, demonstrated to provide charge confinement inside the micrometric sensitive volume, thus minimizing the field-funnelling effect. An innovative segmented telescope device was developed in order to have a silicon detector offering sensitive volume dimensions similar to those which can be simulated by a tissue-equivalent proportional counter (TEPC). The response of the segmented device to hadron beams was characterized with clinical protons and with 62 AMeV carbon ions at the INFN-Laboratori Nazionali del Sud (Catania, Italy). Irradiations with mono-energetic neutrons at the INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy) were also performed. The agreement with the spectra measured with a TEPC is very satisfactory and gives confidence on the application of such a silicon device to assess the quality of hadrontherapy beams.

  2. Conditions for coherent-synchrotron-radiation-induced microbunching suppression in multibend beam transport or recirculation arcs

    OpenAIRE

    C.-Y. Tsai; Di Mitri, S.; Douglas, D; Li, R.; Tennant, C

    2017-01-01

    The coherent synchrotron radiation (CSR) of a high-brightness electron beam traversing a series of dipoles, such as transport or recirculation arcs, may result in beam phase space degradation. On one hand, CSR can perturb electron transverse motion in dispersive regions along the beam line and possibly cause emittance growth. On the other hand, the CSR effect on the longitudinal beam dynamics could result in microbunching instability. For transport arcs, several schemes have been proposed to ...

  3. Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Roeder, M.; Cowan, T.E.; Kempe, M.; Yakorev, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universitaet Dresden, Dresden (Germany); Elekes, Z. [MTA ATOMKI, Debrecen (Hungary); Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Aumann, T.; Caesar, C. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt, Darmstadt (Germany); Bemmerer, D.; Sobiella, M.; Stach, D.; Wagner, A. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K.; Hehner, J.; Heil, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Maroussov, V. [Universitaet zu Koeln, Koeln (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Nusair, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Al-Balqa Applied University, Salt (Jordan); Prokofiev, A.V. [Uppsala University, The Svedberg Laboratory, Uppsala (Sweden); Reifarth, R. [Johann Wolfgang Goethe - Universitaet, Frankfurt am Main (Germany); Zilges, A. [Universitaet zu Koeln, Koeln (Germany); Zuber, K. [Technische Universitaet Dresden, Dresden (Germany); Collaboration: R3B Collaboration

    2014-07-15

    Composite detectors made of stainless-steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175 MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment. (orig.)

  4. Helium-tight Laser Beam Welding of Aluminum with Brillant Laser Beam Radiation

    Science.gov (United States)

    Heinen, Paul; Wu, Hao; Olowinsky, Alexander; Gillner, Arnold

    The substitution of steel as base metal for casings and packaging applications has increased during the last years. Especially aluminum with advantages in weight and machining effort has become a versatile solution for applications in fine mechanics (e.g. sensor housings) and automotive applications. Joining of aluminum components is more critical due to possible crack formation in the joining seam and uneven seam geometry. With the high intensity of brillant laser beam sources the specific challenges of aluminum welding can be overcome. Due to its hydrogen affinity and high degree of reflection for laser radiation at a wavelength of 1 μm (95%) aluminum needs to be welded with proper shielding gas support and high beam quality in order to avoid seam defects. Cracks and pores can lead to non-sufficient tightness for sensor applications and early failure. Housing components have been joined to form a functioning unit in order to seal electrical or measuring components, which are helium-tight for these applications.

  5. Ion beam induced luminescence: Relevance to radiation induced bystander effects

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S.B., E-mail: ahmad.rabilal@gmail.com [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada); McNeill, F.E., E-mail: fmcneill@mcmaster.ca [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada); Byun, S.H., E-mail: soohyun@mcmaster.ca [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada); Prestwich, W.V., E-mail: prestwic@mcmaster.ca [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada); Seymour, C., E-mail: seymouc@mcmaster.ca [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada); Mothersill, C.E., E-mail: mothers@mcmaster.ca [Medical Physics and Applied Radiation Sciences, University of McMaster, Hamilton, Ontario (Canada)

    2012-10-01

    The aim of this work is quantify the light emitted as a result of charged particle interaction in materials which may be of relevance to radiation induced 'bystander effects' studies. We have developed a system which employs single photon counting to measure the light emitted from samples irradiated under vacuum by a charged particle beam. The system uses a fast photomultiplier tube with a peak cathode response at 420 nm. It has been tested in a proof-of-principle experiment using polystyrene targets. Light output, as a result of irradiation, was measured. The luminescence yield appears to have a non-linear behavior with the incident ion fluence: it rises exponentially to an asymptotic value. The target was irradiated with beam energies varying from 1 to 2 MeV and showed saturation at or before an incident fluence rate of 3 Multiplication-Sign 10{sup 13} H{sup +}/cm{sup 2} s. The average saturation value for the photon output was found to be 40 Multiplication-Sign 10{sup 6} cps. Some measurements were performed using filters to study the emission at specific wavelengths. In the case of filtered light measurements, the photon output was found to saturate at 28 Multiplication-Sign 10{sup 3}, 10 Multiplication-Sign 10{sup 6}, and 35 Multiplication-Sign 10{sup 6} cps for wavelengths of 280 {+-} 5 nm, 320 {+-} 5 nm and 340 {+-} 5 nm respectively. The light output reaches a maximum value because of damage induced in the polymer. Our measurements indicate a 'damage cross section' of the order of 10{sup -14} cm{sup 2}. The average radiant intensity was found to increase at wavelengths of 280 and 320 nm when the proton energy was increased. This was not found to occur at 340 nm. In conclusion, the light emission at specific wavelengths was found to depend upon the incident proton fluence and the proton energy. The wavelengths of the emitted light measured in this study have significance for the understanding of radiation induced bystander effects.

  6. Treatment optimisation using external beam radiation in gynaecological cancers

    Directory of Open Access Journals (Sweden)

    V. Sharma

    2004-03-01

    Full Text Available The majority of patients with gynaecological cancers present with advanced stages in which external beam radiation forms a major component of the treatment. These patients undergo simulation for treatment planning prior to radiation. Currently the lower extent of the disease is evaluated by vaginal examination and marked using a lead wire on the anterior abdominal wall in the pelvic region. A 2 cm margin inferior to this level is used as the lower border of the treatment field. The suggested modified technique includes the placement of an indigenously designed perspex vaginal obturator with graduations at 1 cm distance from its tip. Following vaginal examination the obturator can be inserted into the vagina and fixed at the predefined length using a fixation device. The radio-opaque markers can be seen even in the lateral films. Twentyfive consecutive patients underwent the procedure and the differences between the two methods of marking the lower border were calculated. The external lead wire was inferior to the internal obturator in 19 patients (76% ranging from 0.5 cm to 3 cm (median 1.5 cm, mean 1.37 cm. It was at the same level in 4 patients (16% and 1 cm superior to the internal obturator in 2 (8%. With the modified technique using the internal obturator application for delineating the lower border of vaginal disease or vault, it was possible to decrease the length of field thereby reducing the chances of treatment-related toxicity, especially groin and vulval reactions, as well as avoiding treatment interruptions.

  7. Off-axial acoustic radiation force of repulsor and tractor bessel beams on a sphere.

    Science.gov (United States)

    Silva, Glauber T; Lopes, J Henrique; Mitri, Farid G

    2013-06-01

    Acoustic Bessel beams are known to produce an axial radiation force on a sphere centered on the beam axis (on-axial configuration) that exhibits both repulsor and tractor behaviors. The repulsor and the tractor forces are oriented along the beam's direction of propagation and opposite to it, respectively. The behavior of the acoustic radiation force generated by Bessel beams when the sphere lies outside the beam's axis (off-axial configuration) is unknown. Using the 3-D radiation force formulas given in terms of the partial wave expansion coefficients for the incident and scattered waves, both axial and transverse components of the force exerted on a silicone- oil sphere are obtained for a zero- and a first-order Bessel vortex beam. As the sphere departs from the beam's axis, the tractor force becomes weaker. Moreover, the behavior of the transverse radiation force field may vary with the sphere's size factor ka (where k is the wavenumber and a is the sphere radius). Both stable and unstable equilibrium regions around the beam's axis are found, depending on ka values. These results are particularly important for the design of acoustical tractor beam devices operating with Bessel beams.

  8. Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

    Energy Technology Data Exchange (ETDEWEB)

    Du, Weiliang, E-mail: wdu@mdanderson.org; Cho, Sang Hyun; Zhang, Xiaodong; Kudchadker, Rajat J. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Hoffman, Karen E. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2014-02-15

    Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed

  9. Experimental Study of Acoustic Radiation Force of an Ultrasound Beam on Absorbing and Scattering Objects

    Science.gov (United States)

    Nikolaeva, Anastasiia V.; Kryzhanovsky, Maxim A.; Tsysar, Sergey A.; Kreider, Wayne; Sapozhnikov, Oleg A.

    2016-01-01

    Acoustic radiation force is a nonlinear acoustic effect caused by the transfer of wave momentum to absorbing or scattering objects. This phenomenon is exploited in modern ultrasound metrology for measurement of the acoustic power radiated by a source and is used for both therapeutic and diagnostic sources in medical applications. To calculate radiation force an acoustic hologram can be used in conjunction with analytical expressions based on the angular spectrum of the measured field. The results of an experimental investigation of radiation forces in two different cases are presented in this paper. In one case, the radiation force of an obliquely incident ultrasound beam on a large absorber (which completely absorbs the beam) is considered. The second case concerns measurement of the radiation force on a spherical target that is small compared to the beam diameter. PMID:27147775

  10. Experimental study of acoustic radiation force of an ultrasound beam on absorbing and scattering objects

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaeva, Anastasiia V., E-mail: niko200707@mail.ru; Kryzhanovsky, Maxim A.; Tsysar, Sergey A. [Department of Acoustics, Physics Faculty, Moscow State University, Leninskie Gory, Moscow 119991 (Russian Federation); Kreider, Wayne [Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th St. Seattle WA 98105 (United States); Sapozhnikov, Oleg A. [Department of Acoustics, Physics Faculty, Moscow State University, Leninskie Gory, Moscow 119991 (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th St. Seattle WA 98105 (United States)

    2015-10-28

    Acoustic radiation force is a nonlinear acoustic effect caused by the transfer of wave momentum to absorbing or scattering objects. This phenomenon is exploited in modern ultrasound metrology for measurement of the acoustic power radiated by a source and is used for both therapeutic and diagnostic sources in medical applications. To calculate radiation force an acoustic hologram can be used in conjunction with analytical expressions based on the angular spectrum of the measured field. The results of an experimental investigation of radiation forces in two different cases are presented in this paper. In one case, the radiation force of an obliquely incident ultrasound beam on a large absorber (which completely absorbs the beam) is considered. The second case concerns measurement of the radiation force on a spherical target that is small compared to the beam diameter.

  11. SU-E-T-46: A Monte Carlo Investigation of Radiation Interactions with Gold Nanoparticles in Water for 6 MV, 85 KeV and 40 KeV Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Flint, D B; O’Brien, D J; McFadden, C H; Wolfe, T; Krishnan, S; Sawakuchi, G O [UT MD Anderson Cancer Center, Houston, TX. (United States); Hallacy, T M [UT MD Anderson Cancer Center, Houston, TX. (United States); Rice University, Houston, TX (United States)

    2015-06-15

    Purpose: To determine the effect of gold-nanoparticles (AuNPs) on energy deposition in water for different irradiation conditions. Methods: TOPAS version B12 Monte Carlo code was used to simulate energy deposition in water from monoenergetic 40 keV and 85 keV photon beams and a 6 MV Varian Clinac photon beam (IAEA phase space file, 10x10 cm{sup 2}, SSD 100 cm). For the 40 and 85 keV beams, monoenergetic 2x2 mm{sup 2} parallel beams were used to irradiate a 30x30x10 µm {sup 3} water mini-phantom located at 1.5 cm depth in a 30x30x50 cm{sup 3} water phantom. 5000 AuNPs of 50 nm diameter were randomly distributed inside the mini-phantom. Energy deposition was scored in the mini-phantom with the AuNPs’ material set to gold and then water. For the 6 MV beam, we created another phase space (PHSP) file on the surface of a 2 mm diameter sphere located at 1.5 cm depth in the water phantom. The PHSP file consisted of all particles entering the sphere including backscattered particles. Simulations were then performed using the new PHSP as the source with the mini-phantom centered in a 2 mm diameter water sphere in vacuum. The g4em-livermore reference list was used with “EMRangeMin/EMRangeMax = 100 eV/7 MeV” and “SetProductionCutLowerEdge = 990 eV” to create the new PHSP, and “SetProductionCutLowerEdge = 100 eV” for the mini-phantom simulations. All other parameters were set as defaults (“finalRange = 100 µm”). Results: The addition of AuNPs resulted in an increase in the mini-phantom energy deposition of (7.5 ± 8.7)%, (1.6 ± 8.2)%, and (−0.6 ± 1.1)% for 40 keV, 85 keV and 6 MV beams respectively. Conclusion: Enhanced energy deposition was seen at low photon energies, but decreased with increasing energy. No enhancement was observed for the 6 MV beam. Future work is required to decrease the statistical uncertainties in the simulations. This research is partially supported from institutional funds from the Center for Radiation Oncology Research, The

  12. Cone beam computed tomography radiation dose and image quality assessments.

    Science.gov (United States)

    Lofthag-Hansen, Sara

    2010-01-01

    Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image resolution and radiation dose. When new technology is introduced one must make sure that diagnostic accuracy is better or at least as good as the one it can be expected to replace. The CBCT brand tested was two versions of Accuitomo (Morita, Japan): 3D Accuitomo with an image intensifier as detector, FOV 3 cm x 4 cm and 3D Accuitomo FPD with a flat panel detector, FOVs 4 cm x 4 cm and 6 cm x 6 cm. The 3D Accuitomo was compared with intra-oral radiography for endodontic diagnosis in 35 patients with 46 teeth analyzed, of which 41 were endodontically treated. Three observers assessed the images by consensus. The result showed that CBCT imaging was superior with a higher number of teeth diagnosed with periapical lesions (42 vs 32 teeth). When evaluating 3D Accuitomo examinations in the posterior mandible in 30 patients, visibility of marginal bone crest and mandibular canal, important anatomic structures for implant planning, was high with good observer agreement among seven observers. Radiographic techniques have to be evaluated concerning radiation dose, which requires well-defined and easy-to-use methods. Two methods: CT dose index (CTDI), prevailing method for CT units, and dose-area product (DAP) were evaluated for calculating effective dose (E) for both units. An asymmetric dose distribution was revealed when a clinical situation was simulated. Hence, the CTDI method was not applicable for these units with small FOVs. Based on DAP values from 90 patient examinations effective dose was estimated for three diagnostic tasks: implant planning in posterior mandible and

  13. Coherent X-ray radiation excited by a diverging relativistic electron beam in a single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Blazhevich, S. V., E-mail: noskovbupk@mail.ru; Noskov, A. V. [Belgorod State National Research University (Russian Federation)

    2015-05-15

    We develop a dynamic theory of coherent X-rays generated in a single-crystal wafer by a diverging relativistic electron beam. The dependence of the spectral-angular density of coherent X-ray radiation on the angle of divergence is analyzed for the case when the angular spread can be described by the 2D Gaussian distribution. The theory constructed here makes it possible to analyze coherent radiation for an arbitrary angular distribution of electrons in the beam as well.

  14. Optical Transition Radiation Measurement of Electron Beam for Beijing Free Electron Laser

    Institute of Scientific and Technical Information of China (English)

    ZHAO Qiang; XIE Jia-Lin; LI Yong-Gui; ZHUANG Jie-Jia

    2001-01-01

    We used transition radiation techniques instead of the original phosphor targets to improve the electronic beam diagnostic system at Beijing Free Electron Laser. The beam profile, size (3.3 × 2.4 mm), position and divergence angle (σrms = 2.5 mrad) in transverse have been obtained from optical transition radiation. We also present the experimental set-up and some preliminary results.

  15. Bronchiolitis obliterans organizing pneumonia after tangential beam irradiation to the breast. Discrimination from radiation pneumonitis

    Energy Technology Data Exchange (ETDEWEB)

    Nambu, Atsushi; Ozawa, Katsura; Kanazawa, Masaki; Miyata, Kazuyuki [Kofu Municipal Hospital (Japan); Araki, Tsutomu; Ohki, Zennosuke [Yamanashi Medical Coll., Tamaho (Japan)

    2002-06-01

    We report a case of bronchiolitis obliterans organizing pneumonia (BOOP) secondary to tangential beam irradiation to the breast, which occurred seven months after the completion of radiotherapy. Although radiation pneumonitis is an alternative consideration, BOOP could be differentiated from it by its relatively late onset and extensive distribution, which did not respect the radiation field. This disease should always be kept in mind in patients with a history of tangential beam irradiation to the breast. (author)

  16. An analysis of whistler mode radiation from the Spacelab 2 electron beam

    Science.gov (United States)

    Farrell, W. M.; Gurnett, D. A.; Banks, P. M.; Bush, R. I.; Raitt, W. J.

    1988-01-01

    During the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the Shuttle to free fly. At times during this free flight, when the PDP was magnetically connected to the Shuttle, Stanford's fast-pulsed electron generator, located in the Shuttle cargo bay, ejected a 1-keV 50-mA electron beam. The PDP plasma-wave instrument detected intense whistler-mode radiation during these beam ejections. This paper presents a study of a whistler mode emission detected during one particular continuous electron beam firing. Calculations indicate that the beam radiated approximately 1.6 mW in the whistler mode as the beam traversed the 200 m from the Shuttle to the PDP. The emissivity also decreased by about a factor of 10 over this same distance. The measured wave powers are 10 to the 7th greater than wave powers expected from incoherent Cerenkov radiation, verifying that the radiation is generated by a coherent process. Estimates of the emissivity based on measured electric field intensities in the beam indicate that the whistler-mode noise is produced by radiation from electron bunches created by an electrostatic beam-plasma instability.

  17. Observation of monoenergetic protons from a near-critical gas target tailored by a hydrodynamic shock

    Science.gov (United States)

    Chen, Y.-H.; Helle, M. H.; Ting, A.; Gordon, D. F.; Polyanskiy, M. N.; Pogorelsky, I.; Babzien, M.; Najmudin, Z.

    2015-05-01

    We present our recent experimental results of monoenergetic protons accelerated from the interaction of an intense terawatt CO2 laser pulse with a near-critical hydrogen gas target, with its density profile tailored by a hydrodynamic shock. A 5-ns Nd:YAG laser pulse is focused onto a piece of stainless steel foil mounted at the front edge of the gas jet nozzle orifice. The ablation launches a spherical shock into the near-critical gas column, which creates a sharp density gradient at the front edge of the target, with ~ 6X local density enhancement up to several times of critical density within ~<100 microns. With such density profile, we have obtained monoenergetic proton beams with good shot-to-shot reproducibility and energies up to 1.2 MeV.

  18. Generation of quasi-monoenergetic carbon ions accelerated parallel to the plane of a sandwich target

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J. W., E-mail: wang-jw@ile.osaka-u.ac.jp [Institute of Laser Engineering, Osaka University, Osaka 565-0871 (Japan); Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Murakami, M.; Weng, S. M. [Institute of Laser Engineering, Osaka University, Osaka 565-0871 (Japan); Xu, H. [National Laboratory for Parallel and Distributed Processing, School of Computer Science, National University of Defense Technology, Changsha 410073 (China); Ju, J. J.; Luan, S. X.; Yu, W. [Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2014-12-15

    A new ion acceleration scheme, namely, target parallel Coulomb acceleration, is proposed in which a carbon plate sandwiched between gold layers is irradiated with intense linearly polarized laser pulses. The high electrostatic field generated by the gold ions efficiently accelerates the embedded carbon ions parallel to the plane of the target. The ion beam is found to be collimated by the concave-shaped Coulomb potential. As a result, a quasi-monoenergetic and collimated C{sup 6+}-ion beam with an energy exceeding 10 MeV/nucleon is produced at a laser intensity of 5 × 10{sup 19} W/cm{sup 2}.

  19. The effects of x-ray beam hardening on detective quantum efficiency and radiation dose.

    Science.gov (United States)

    Wong, Molly Donovan; Wu, Xizeng; Liu, Hong

    2011-01-01

    The goal of this preliminary study was to investigate the effects of x-ray beam hardening on the detective quantum efficiency (DQE) and the radiation dose of an inline x-ray imaging system. The ability to decrease the risk of harmful radiation to the patient without compromising the detection capability would more effectively balance the tradeoff between image quality and radiation dose, and therefore benefit the fields of diagnostic x-ray imaging, especially mammography. The DQE and the average glandular dose were both calculated under the same experimental conditions for a range of beam hardening levels, corresponding to no added beam hardening and two thicknesses each of Rhodium (Rh) and Molybdenum (Mo) filters. The dose calculation results demonstrate a reduction of 15% to 24% for the range of beam hardening levels. The comparison of all quantities comprising the DQE exhibit very close correlation between the results obtained without added beam hardening to the results corresponding to the range of beam hardening levels. For the specific experimental conditions utilized in this preliminary study, the results are an indication that the use of beam hardening holds the potential to reduce the radiation dose without decreasing the performance of the system. Future studies will seek to apply this method in a clinical environment and perform a comprehensive image quality evaluation, in an effort to further evaluate the potential of beam hardening to balance the tradeoff between dose and image quality.

  20. Coherent undulator radiation of electron beam, microbunched for the FEL power outcoupling

    Energy Technology Data Exchange (ETDEWEB)

    Kulipanov, G.N.; Sokolov, A.S.; Vinokurov, N.A. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation)

    1995-12-31

    The spectral intensity of the coherent undulator radiation of electron beam, preliminarily microbunched by the FEL oscillator for the FEL power outcoupling, is approximately calculated by simple analytic considerations, taking into account the transverse emittances and the energy spread of the microbunched electron beams.

  1. Radiation protection systems for the final focus test beam at SLAC.

    Science.gov (United States)

    Rokni, S H; Benson, E C; Burke, D L; Jenkins, T M; Liu, J C; Nelson, G; Nelson, W R; Smith, H E; Tenenbaum, P; Vylet, V; Walz, D R

    1996-11-01

    The Final Focus Test Beam (FFTB) is a new beam line at the Stanford Linear Accelerator Center designed to test new beam optics concepts, hardware, and techniques necessary to achieve and measure the small spot sizes required for future generations of high-energy e+e- linear colliders. The FFTB takes a 47 GeVc-1, 1 kW electron beam at the end of the Stanford Linear Accelerator Center linear accelerator and transports it to the FFTB beam dump. A radiation protection system was designed and installed for the FFTB with the primary goal that the integrated dose equivalent outside the shielding resulting from beam loss would not exceed 10 mSv y-1. This system is comprised of shielding, a beam containment system and a personnel protection system. This paper presents various aspects of radiation safety at Stanford Linear Accelerator Center that were considered in the design of the FFTB radiation protection system. Beam tests were conducted in which the performance of various beam containment devices and the shielding effectiveness were evaluated. Preliminary results from these tests are presented.

  2. Summary report of working group 5: Beam and radiation generation, monitoring, and control

    Energy Technology Data Exchange (ETDEWEB)

    Church, Mike; /Fermilab; Kim, Ki-Yong; /Maryland U.

    2010-01-01

    This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.

  3. A Monitor and Control System for the Synchrotron Radiation Beam Lines at DAΦNE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Three synchrotron radiation beam lines have been built on DAΦNE,the Frascati electron-positron accelerator.It is Possible to monitor and control all the elements on the beam lines using a modular network distributed I/O system by National Instrunments (FieldPoint) with Bridge VIEW/Lab VIEW programs,Two of these beam lines have radiation safety problems solved by two independent and redundant systems,using mechanical switches ,and S7-200 PLC's by Siemens.In this article our solution will be described in details.

  4. Summary report of working group 5: Beam and radiation generation, monitoring, and control

    CERN Document Server

    Church, Mike; 10.1063/1.3520295

    2012-01-01

    This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.

  5. Development and Optimisation of the SPS and LHC beam diagnostics based on Synchrotron Radiation monitors

    CERN Document Server

    AUTHOR|(CDS)2081364; Roncarolo, Federico

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing t...

  6. Real-time dosimetry in external beam radiation therapy

    Institute of Scientific and Technical Information of China (English)

    Ramachandran; Prabhakar

    2013-01-01

    With growing complexity in radiotherapy treatment delivery,it has become mandatory to check each and every treatment plan before implementing clinically.This process is currently administered by an independent secondary check of all treatment parameters and as a pre-treatment quality assurance (QA) check for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy treatment plans.Although pre-treatment IMRT QA is aimed to ensure the correct dose is delivered to the patient,it does not necessarily predict the clinically relevant patient dose errors.During radiotherapy,treatment uncertainties can affect tumor control and may increase complications to surrounding normal tissues.To combat this,image guided radiotherapy is employed to help ensure the plan conditions are mimicked on the treatment machine.However,it does not provide information on actual delivered dose to the tumor volume.Knowledge of actual dose delivered during treatment aid in confirming the prescribed dose and also to replan/reassess the treatment in situations where the planned dose is not delivered as expected by the treating physician.Major accidents in radiotherapy would have been averted if real time dosimetry is incorporated as part of the routine radiotherapy procedure.Of late real-time dosimetry is becoming popular with complex treatments in radiotherapy.Realtime dosimetry can be either in the form of point doses or planar doses or projected on to a 3D image dataset to obtain volumetric dose.They either provide entrance dose or exit dose or dose inside the natural cavities of a patient.In external beam radiotherapy,there are four different established platforms whereby the delivered dose information can be obtained:(1)Collimator;(2)Patient;(3)Couch;and(4)Electronic Portal Imaging Device.Current real-time dosimetric techniques available in radiotherapy have their own advantages and disadvantages and a combination of one or more of these methods provide vital information

  7. Off-axial acoustic radiation force of pressor and tractor Bessel beams on a sphere

    CERN Document Server

    Silva, Glauber T; Lobo, Tiago P; Mitri, Farid G

    2012-01-01

    Acoustic Bessel beams are known to produce an axial radiation force on a sphere centered on the beam axis (on-axial configuration) that exhibits both "pressor" and "tractor" behaviors. The pressor and the tractor forces are oriented along the beam's direction of propagation and opposite to it, respectively. The behavior of the acoustic radiation force generated by Bessel beams when the sphere lies outside the beam's axis (off-axial configuration) is unknown. Using the 3D radiation force formulas given in terms of the partial wave expansion coefficients for the incident and scattered waves, both axial and transverse components of the force exerted on a silicone-oil sphere are obtained for a zero- and a first-order Bessel vortex beam. As the sphere departs from the beam's axis, the tractor force becomes weaker. Moreover, the behavior of the transverse radiation force field may vary with the sphere's size factor $ka$ (where $k$ is the wavenumber and $a$ is the sphere radius). Both stable and unstable equilibrium...

  8. Measurement of the track structure of ionizing radiation; Messung der Spurstruktur ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Hilgers, Gerhard [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe ' Nanodosimetrie'

    2013-06-15

    After a description of the nanodosimetric measurement quantities of tracks induced by ionizing radiation the nanodosemeter operated in the PTB is described. Finally the scaling behaviour of nanodosimetry is considered. In order to test the validity of the corresponding equation ionization-cluster size distributions were measured with monoenergetic proton and alpha beams in the energy range from 0.1 to 20 MeV with propane and nitrogen as measuring gases. (HSI)

  9. Radiation monitoring and beam dump system of the OPAL silicon microvertex detector

    Science.gov (United States)

    Biebel, O.; Braibant, S.; de Jong, S. J.; Hammarström, R.; Hilgers, R.; Honma, A. K.; Jovanovic, P.; Lauber, J. A.; Neal, H. A.

    1998-02-01

    The radiation monitoring and beam dump system of the OPAL silicon microvertex detector is described. This system was designed and implemented to measure the radiation dose over time scales varying from a millisecond to a year, and to induce a fast beam dump if the radiation exceeds a given threshold in dose and in dose rate within a very small time interval. The system uses reverse-biased silicon diodes as sensitive elements and good stability is achieved by AC coupling of the amplifiers to the sensors.

  10. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon, Ricardo [Arizona State University, Glendale, AZ (United States); Balascuta, S. [Arizona State University, Glendale, AZ (United States); Benson, Stephen V. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Bertozzi, William [Massachusetts Institute of Technology, Cambridge, MA (United States); Boyce, James R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cowan, Ray [Massachusetts Institute of Technology, Cambridge, MA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Evtushenko, Pavel [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Fisher, P. [Massachusetts Institute of Technology, Cambridge, MA (United States); Ihloff, Ernest E. [Hampton University, Hampton, VA (United States); Kalantarians, Narbe [Hampton University, Hampton, VA (United States); Kelleher, Aidan Michael [Massachusetts Institute of Technology, Cambridge, MA (United States); Krossler, W. J. [William and Mary College, Williamsburg, VA (United States); Legg, Robert A. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Long, Elena [University of New Hampshire, Durham, NH (United States); Milner, Richard [Massachusetts Institute of Technology, Cambridge, MA (United States); Neil, George R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ou, Longwu [Massachusetts Institute of Technology, Cambridge, MA (United States); Schmookler, Barack Abraham [Massachusetts Institute of Technology, Cambridge, MA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Tschalar, C. [Massachusetts Institute of Technology, Cambridge, MA (United States); Williams, Gwyn P. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, Shukui [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2013-11-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

  11. Detailed Resolution Studies of the Synchrotron Radiation Profile Monitor for the HERA Electron Beam

    CERN Document Server

    Kube, G; Wittenburg, K

    2005-01-01

    The precise determination of the beam emittance is essential for the understanding of the luminosity in colliding beam experiments as the ones at the e-p storage ring HERA at DESY. For the measurement of the electron beam emittance a monitor is used which is based on the direct imaging of visible synchrotron radiation from a bending magnet. In order to reduce the thermal heating of the light extracting beryllium mirror it is moved away from the beam axis in vertical direction. While the resolution of profile measurements by synchrotron radiation is already strictly limited by fundamental effects, the observation in off-axis geometry modifies the intensity distribution additionally leading to an increased contribution of the diffraction limited resolution. In order to describe the resolution broadening effects detailed calculations have been performed with the computer code SRW. Taking into account the calculated corrections the deduced beam emittances are in good agreement with independent measurements from a...

  12. Acoustic radiation force of high-order Bessel beam standing wave tweezers on a rigid sphere.

    Science.gov (United States)

    Mitri, F G

    2009-12-01

    Particle manipulation using the acoustic radiation force of Bessel beams is an active field of research. In a previous investigation, [F.G. Mitri, Acoustic radiation force on a sphere in standing and quasi-standing zero-order Bessel beam tweezers, Annals of Physics 323 (2008) 1604-1620] an expression for the radiation force of a zero-order Bessel beam standing wave experienced by a sphere was derived. The present work extends the analysis of the radiation force to the case of a high-order Bessel beam (HOBB) of positive order m having an angular dependence on the phase phi. The derivation for the general expression of the force is based on the formulation for the total acoustic scattering field of a HOBB by a sphere [F.G. Mitri, Acoustic scattering of a high-order Bessel beam by an elastic sphere, Annals of Physics 323 (2008) 2840-2850; F.G. Mitri, Equivalence of expressions for the acoustic scattering of a progressive high order Bessel beam by an elastic sphere, IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 56 (2009) 1100-1103] to derive the general expression for the radiation force function YJm,st(ka,beta,m)Bessel beam standing wave incident upon a rigid sphere immersed in non-viscous water are computed. The rigid sphere calculations for YJm,st(ka,beta,m)Bessel beam standing wave (m=0). The proposed theory is of particular interest essentially due to its inherent value as a canonical problem in particle manipulation using the acoustic radiation force of a HOBB standing wave on a sphere. It may also serve as the benchmark for comparison to other solutions obtained by strictly numerical or asymptotic approaches.

  13. LIPAc personnel protection system for realizing radiation licensing conditions on injector commissioning with deuteron beam

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroki, E-mail: takahashi.hiroki@jaea.go.jp [IFMIF/EVEDA Accelerator Group, Japan Atomic Energy Agency (JAEA), Rokkasho, Aomori (Japan); Narita, Takahiro; Kasugai, Atsushi [IFMIF/EVEDA Accelerator Group, Japan Atomic Energy Agency (JAEA), Rokkasho, Aomori (Japan); Kojima, Toshiyuki [Gitec Co. Ltd., Hachinohe, Aomori (Japan); Marqueta, Alvaro; Nishiyama, Koichi [IFMIF/EVEDA Project Team, Rokkasho, Aomori (Japan); Sakaki, Hironao [Quantum Beam Science Center, JAEA, Kizu, Kyoto (Japan); Gobin, Raphael [Commissariat à l’Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, Gif/Yvette (France)

    2016-11-01

    Highlights: • Personnel Protection System (PPS) is developed to adapt the radiation licensing. • PPS achieves the target performance to secure the personnel safety. • Pulse Duty Management System (PDMS) is developed to manage the beam-operation-time. • Satisfying performance of PDMS is confirmed by injector operation with H+ beam. • By the result of PPS and PDMS tests, the radiation license was successfully obtained. - Abstract: The performance validation of the Linear IFMIF Prototype Accelerator (LIPAc), up to the energy of 9 MeV deuteron beam with 125 mA continuous wave (CW), is planned in Rokkasho, Japan. There are three main phases of LIPAc performance validation: Injector commissioning, RFQ commissioning and LIPAc commissioning. Injector commissioning was started by H{sup +} and D{sup +} beam. To apply the radiation licensing for the Injector commissioning, the entering/leaving to/from accelerator vault should be under control, and access to the accelerator vault has to be prohibited for any person during the beam operation. The Personnel Protection System (PPS) was developed to adapt the radiation licensing conditions. The licensing requests that PPS must manage the accumulated D{sup +} current. So, to manage the overall D{sup +} beam time during injector operation, Pulse Duty Management System (PDMS) was developed as a configurable subsystem as part of the PPS. The PDMS was tested during H{sup +} beam (as simulated D{sup +}) operation, to confirm that it can handle the beam inhibit from Injector before the beam accumulation is above the threshold value specified in the radiation licensing condition. In this paper, the design and configuration of these systems and the result of the tests are presented.

  14. Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.

    Science.gov (United States)

    Alaei, Parham; Spezi, Emiliano

    2012-11-08

    The feasibility of accounting of the dose from kilovoltage cone-beam CT in treatment planning has been discussed previously for a single cone-beam CT (CBCT) beam from one manufacturer. Modeling the beams and computing the dose from the full set of beams produced by a kilovoltage cone-beam CT system requires extensive beam data collection and verification, and is the purpose of this work. The beams generated by Elekta X-ray volume imaging (XVI) kilovoltage CBCT (kV CBCT) system for various cassettes and filters have been modeled in the Philips Pinnacle treatment planning system (TPS) and used to compute dose to stack and anthropomorphic phantoms. The results were then compared to measurements made using thermoluminescent dosimeters (TLDs) and Monte Carlo (MC) simulations. The agreement between modeled and measured depth-dose and cross profiles is within 2% at depths beyond 1 cm for depth-dose curves, and for regions within the beam (excluding penumbra) for cross profiles. The agreements between TPS-calculated doses, TLD measurements, and Monte Carlo simulations are generally within 5% in the stack phantom and 10% in the anthropomorphic phantom, with larger variations observed for some of the measurement/calculation points. Dose computation using modeled beams is reasonably accurate, except for regions that include bony anatomy. Inclusion of this dose in treatment plans can lead to more accurate dose prediction, especially when the doses to organs at risk are of importance.

  15. Effects of high-energy-pulse-electron beam radiation on biomacromolecules

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    To study the molecular mechanism of high mutation frequency induced by high-energy-pulse-electron (HEPE) beam radiation, the effects of HEPE radiation on yeast cells, plasma membrane, plasmid DNA, and protein activity were investigated by means of cell counting, gel electrophoresis, AO/EB double fluorescent staining, etc. The results showed that the viability of yeast cells declined statistically with increase of absorbed doses. The half lethal dose (LD50) was 134 Gy. HEPE beam radiation had little influence on the function of plasma membrane and protein, while it could induce much DNA damage of single strand breaks (SSB) and double strand breaks (DSB) that were required for gene mutation. The G-value for DSB formation of HEPE beam radiation in aqueous solution was 5.7 times higher than that caused by 60Co gamma rays. HEPE can be a new effective method for induced mutation breeding and deserves further research in the future.

  16. Acoustical and optical radiation pressure and the development of single beam acoustical tweezers

    Science.gov (United States)

    Thomas, Jean-Louis; Marchiano, Régis; Baresch, Diego

    2017-07-01

    Studies on radiation pressure in acoustics and optics have enriched one another and have a long common history. Acoustic radiation pressure is used for metrology, levitation, particle trapping and actuation. However, the dexterity and selectivity of single-beam optical tweezers are still to be matched with acoustical devices. Optical tweezers can trap, move and position micron size particles, biological samples or even atoms with subnanometer accuracy in three dimensions. One limitation of optical tweezers is the weak force that can be applied without thermal damage due to optical absorption. Acoustical tweezers overcome this limitation since the radiation pressure scales as the field intensity divided by the speed of propagation of the wave. However, the feasibility of single beam acoustical tweezers was demonstrated only recently. In this paper, we propose a historical review of the strong similarities but also the specificities of acoustical and optical radiation pressures, from the expression of the force to the development of single-beam acoustical tweezers.

  17. Cooling of relativistic electron beams in intense laser pulses: Chirps and radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoffe, S.R., E-mail: sam.yoffe@strath.ac.uk; Noble, A., E-mail: adam.noble@strath.ac.uk; Macleod, A.J., E-mail: alexander.macleod@strath.ac.uk; Jaroszynski, D.A., E-mail: d.a.jaroszynski@strath.ac.uk

    2016-09-01

    Next-generation high-power laser facilities (such as the Extreme Light Infrastructure) will provide unprecedented field intensities, and will allow us to probe qualitatively new physical regimes for the first time. One of the important fundamental questions which will be addressed is particle dynamics when radiation reaction and quantum effects play a significant role. Classical theories of radiation reaction predict beam cooling in the interaction of a relativistic electron bunch and a high-intensity laser pulse, with final-state properties only dependent on the laser fluence. The observed quantum suppression of this cooling instead exhibits a dependence on the laser intensity directly. This offers the potential for final-state properties to be modified or even controlled by tailoring the intensity profile of the laser pulse. In addition to beam properties, quantum effects will be manifest in the emitted radiation spectra, which could be manipulated for use as radiation sources. We compare predictions made by classical, quasi-classical and stochastic theories of radiation reaction, and investigate the influence of chirped laser pulses on the observed radiation spectra. - Highlights: • Classical theories of radiation reaction predict electron beam cooling in high fields. • Quantum effects lead to a reduction in electron beam cooling. • Quasi-classical model agrees with predictions from a single-emission stochastic model. • Negative frequency chirp found to increase photon emission, but not maximum energy.

  18. Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chuyu [Peking Univ., Beijing (China)

    2012-12-31

    Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the

  19. ATLAS Transition Radiation Tracker test-beam results

    CERN Document Server

    Åkesson, T; Baker, K; Baron, S; Benjamin, D; Bertelsen, H; Bondarenko, V; Bychkov, V; Callahan, J; Capéans-Garrido, M; Cardiel-Sas, L; Catinaccio, A; Cetin, S A; Cwetanski, Peter; Dam, M; Danielsson, H; Dittus, F; Dolgoshein, B A; Dressnandt, N; Driouichi, C; Ebenstein, W L; Eerola, Paule Anna Mari; Farthouat, Philippe; Fedin, O; Froidevaux, D; Gagnon, P; Grichkevitch, Y; Grigalashvili, N S; Hajduk, Z; Hansen, P; Kayumov, F; Keener, P T; Kekelidze, G D; Khristatchev, A; Konovalov, S; Koudine, L; Kovalenko, S; Kowalski, T; Kramarenko, V A; Krüger, K; Laritchev, A; Lichard, P; Luehring, F C; Lundberg, B; Maleev, V; Markina, I; McFarlane, K W; Mialkovski, V; Mitsou, V A; Mindur, B; Morozov, S; Munar, A; Muraviev, S; Nadtochy, A; Newcomer, F M; Ögren, H O; Oh, S H; Oleshko, S; Olszowska, J; Passmore, S; Patritchev, S; Peshekhonov, V D; Petti, R; Price, M; Rembser, C; Rohne, O; Romaniouk, A; Rust, D R; Ryabov, Yu; Shchegelskii, V; Seliverstov, D M; Shin, T; Shmeleva, A; Smirnov, S; Sosnovtsev, V V; Soutchkov, V; Spiridenkov, E; Tikhomirov, V; Van Berg, R; Vassilakopoulos, V I; Vassilieva, L; Wang, C; Williams, H H; Zalite, A

    2004-01-01

    Several prototypes of the Transition Radiation Tracker for the ATLAS experiment at the LHC have been built and tested at the CERN SPS accelerator. Results from detailed studies of the straw-tube hit registration efficiency and drift-time measurements and of the pion and electron spectra without and with radiators are presented. (10 refs).

  20. Smith-Purcell terahertz radiation from laser modulated electron beam over a metallic grating

    Science.gov (United States)

    Kumar, Pawan; Bhasin, Lalita; Tripathi, V. K.; Kumar, Ashok; Kumar, Manoj

    2016-09-01

    We propose a novel scheme of terahertz (THz) radiation generation from the beat frequency modulation of an electron beam by two co-propagating lasers and the generation of terahertz radiation by the modulated beam passing over a periodic metallic grating. The lasers cause velocity modulation of the beam by exerting a longitudinal ponderomotive force on it. In the drift space between the modulator and metallic grating, the velocity modulation translates into density and current modulation. The modulated beam, propagating over the grating of specific wave number, induces space periodic image current in the conductor that emits beat frequency Smith-Purcell radiation. With 1 μm, 4 × 1016 W/cm2 lasers, beam current modulation of the order of 50% can be achieved at optimum lengths of the modulator and drift space. Employing 10 mA, 0.5 MeV short-period electron beam, propagating at a height of 50 μ m above the grating of period 150 μm, one may obtain THz radiated power of the order of 6 mW at 10 THz.

  1. A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning

    Science.gov (United States)

    Zhang, H. H.; Gao, S.; Chen, W.; Shi, L.; D'Souza, W. D.; Meyer, R. R.

    2013-03-01

    An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equally-spaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality.

  2. Radiation torque on an absorptive spherical drop centered on an acoustic helicoidal Bessel beam

    Science.gov (United States)

    Zhang, Likun; Marston, Philip L.

    2009-11-01

    Circularly polarized electromagnetic waves carry axial angular momentum and analysis shows that the axial radiation torque on an illuminated sphere is proportional to the power absorbed by the sphere [1]. Helicoidal acoustic beams also carry axial angular momentum and absorption of such a beam should also produce an axial radiation torque [2]. In the present work the acoustic radiation torque on solid spheres and spherical drops centered on acoustic helicoidal Bessel beams is examined. The torque is predicted to be proportional to the ratio of the absorbed power to the acoustic frequency. Depending on the beam helicity, the torque is parallel or anti-parallel to the beam axis. The analysis uses a relation between the scattering and the partial wave coefficients for a sphere in a helicoidal Bessel beam. Calculations suggest that beams with a low topological charge are more efficient for generating torques on solid spheres.[4pt] [1] P. L. Marston and J. H. Crichton, Phys. Rev. A. 30, 2508-2516 (1984).[0pt] [2] B. T. Hefner and P. L. Marston, J. Acoust. Soc. Am. 106, 3313-3316 (1999).

  3. Mechanism analysis of radiation generated by the beam-plasma interaction in a vacuum diode

    Science.gov (United States)

    Zengchao, Ji; Shixiu, Chen; Shen, Gao

    2017-01-01

    When we were studying the vacuum switch, we found that the vacuum diode can radiate a broadband microwave. The vacuum diode is comprised of a cathode with a trigger device and planar anode, there is not a metallic bellows waveguide structure in this device, so the radiation mechanism of the vacuum diode is different from the plasma filled microwave device. It is hard to completely imitate the theory of the plasma filled microwave device. This paper analyzes the breakdown process of the vacuum diode, establishes the mathematical model of the radiating microwave from the vacuum diode. Based on the analysis of the dispersion relation in the form of a refractive index, the electromagnetic waves generated in the vacuum diode will resonate. The included angle between the direction of the electromagnetic radiation and the initial motion direction of electron beam is 45 degrees. The paper isolates the electrostatic effect from the beam-plasma interaction when the electromagnetic radiation occurs. According to above analyses, the dispersion relations of radiation are obtained by solving the wave equation. The dispersion curves are also obtained based on the theoretical dispersion relations. The theoretical dispersion curves are consistent with the actual measurement time-frequency maps of the radiation. Theoretical deduction and experiments indicate that the reason for microwave radiating from the vacuum diode can be well explained by the interaction of the electron beam and magnetized plasma. Supported by National Nature Science Foundation of China (No. 11075123), the Young Scientists Fund of Nature Science Foundation of China (No. 51207171).

  4. TH-C-17A-09: Direct Visualization and Monitoring of Medical Radiation Beams in Air

    Energy Technology Data Exchange (ETDEWEB)

    Fahimian, B; Ceballos, A; Turkcan, S; Kapp, D; Pratx, G [Stanford University, Stanford, CA (United States)

    2014-06-15

    Purpose: Radiation therapy errors are rare but potentially catastrophic. Recent fatal incidents could have been avoided by utilizing real-time methods of monitoring delivery of radiation during treatment. However, few existing methods are practical enough to be used routinely. The study presents the first experimental demonstration of a novel non-perturbing method of monitoring radiation therapy through the phenomena of air scintillation. Methods: Monitoring of radiation delivery was devised by leveraging the phenomena of nitrogen excitation in air by ionizing radiation. The excitation induced weak luminescence in the 300–400 nm range, a process called air scintillation. An electron-multiplication charge-coupled device camera (f/0.95 lens; 440 nm shortpass) was set-up in a clinical treatment vault and was used to capture air scintillation images of kilovoltage and megavoltage beams. Monte Carlo simulations were performed to determine the correlation of radiation dose to air scintillation. Results: Megavoltage beams from a Varian Clinac 21EX and kilovoltage beams from an orthovoltage unit (50 kVp, 30 mA) were visualized with a relatively short exposure time (10 s). Cherenkov luminescence produced in a plastic transparent phantom did not interfere with detection of air scintillation. The image intensity displayed an inverse intensity falloff (r{sup 2} = 0.89) along the central axis and was proportional to dose rate (r{sup 2} = 0.9998). As beam energy increased, the divergence of the imaged beam decreased. Last, air scintillation was visualized during a simulated total skin irradiation electron treatment. Conclusion: Air scintillation can be clinically detected to monitor a radiation beam in an inexpensive and non-perturbing manner. This new method is advantageous in monitoring for gross delivery and uniquely capable of wide area in a single acquisition, such as the case for online verification of total body / skin / lymphoid irradiation treatments.

  5. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    CERN Document Server

    Alarcon, R; Benson, S.V.; Bertozzi, W.; Boyce, J.R.; Cowan, R.; Douglas, D.; Evtushenko, P.; Fisher, P.; Ihloff, E.; Kalantarians, N.; Kelleher, A.; Kossler, W.J.; Legg, R.; Long, E.; Milner, R.G.; Neil, G.R.; Ou, L.; Schmookler, B.; Tennant, C.; TschaläR, C.; Williams, G.P.; Zhang, S.

    2013-01-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is ...

  6. Visible-light beam size monitors using synchrotron radiation at CESR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.T., E-mail: sw565@cornell.edu [Cornell Laboratory for Accelerator-Based Science and Education, Cornell University, Ithaca, NY 14853 (United States); Rubin, D.L.; Conway, J.; Palmer, M.; Hartill, D. [Cornell Laboratory for Accelerator-Based Science and Education, Cornell University, Ithaca, NY 14853 (United States); Campbell, R.; Holtzapple, R. [Physics Department, California Polytechnic State University, San Luis Obispo, CA 93407 (United States)

    2013-03-01

    A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 μm can be measured with a resolution of approximately 5 μm. To measure larger beam size (>500 μm), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the π-polarized component of SR, a small vertical beam size (∼70 μm) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.

  7. Correlations between values of daily beam, diffuse and global radiation for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Ianetz, A. (Israel Meteorological Service, Bet Dagan (Israel). Research and Development Dept.); Kudish, A.I. (Ben-Gurion Univ. of the Negev, Beersheba (Israel). Dept. of Chemical Engineering)

    1992-06-01

    Empirical correlations for predicting both beam and diffuse radiation at Beer Sheva, located in the semi-arid southern region of Israel, have been developed. These equations relate either the beam or the diffuse fraction of the global radiation to the clearness index. The available data, composed of normal incidence beam and global radiation measurements, have been analyzed on both a seasonal and a yearly basis. They have been compared to empirical equations previously reported in the literature for six sites in the Middle East region. In the case of Qidron, Israel, and three Greek sites, there was close agreement between the correlations, whereas in the remaining two sites (Gilat, Israel and Fudhaliyah, Iraq) the correlations were quite different. Reasons for the discrepancies in the latter two cases are presented in the text. (author).

  8. Betatron radiation based diagnostics for plasma wakefield accelerated electron beams at the SPARC_LAB test facility

    Science.gov (United States)

    Shpakov, V.; Anania, M. P.; Biagioni, A.; Chiadroni, E.; Cianchi, A.; Curcio, A.; Dabagov, S.; Ferrario, M.; Filippi, F.; Marocchino, A.; Paroli, B.; Pompili, R.; Rossi, A. R.; Zigler, A.

    2016-09-01

    Recent progress with wake-field acceleration has shown a great potential in providing high gradient acceleration fields, while the quality of the beams remains relatively poor. Precise knowledge of the beam size at the exit from the plasma and matching conditions for the externally injected beams are the key for improvement of beam quality. Betatron radiation emitted by the beam during acceleration in the plasma is a powerful tool for the transverse beam size measurement, being also non-intercepting. In this work we report on the technical solutions chosen at SPARC_LAB for such diagnostics tool, along with expected parameters of betatron radiation.

  9. Transient Self-Amplified Cerenkov Radiation with a Short Pulse Electron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Poole, B R; Blackfield, D T; Camacho, J F

    2009-01-22

    An analytic and numerical examination of the slow wave Cerenkov free electron maser is presented. We consider the steady state amplifier configuration as well as operation in the selfamplified spontaneous emission (SASE) regime. The linear theory is extended to include electron beams that have a parabolic radial density inhomogeneity. Closed form solutions for the dispersion relation and modal structure of the electromagnetic field are determined in this inhomogeneous case. To determine the steady state response, a macro-particle approach is used to develop a set of coupled nonlinear ordinary differential equations for the amplitude and phase of the electromagnetic wave, which are solved in conjunction with the particle dynamical equations to determine the response when the system is driven as an amplifier with a time harmonic source. We then consider the case in which a fast rise time electron beam is injected into a dielectric loaded waveguide. In this case, radiation is generated by SASE, with the instability seeded by the leading edge of the electron beam. A pulse of radiation is produced, slipping behind the leading edge of the beam due to the disparity between the group velocity of the radiation and the beam velocity. Short pulses of microwave radiation are generated in the SASE regime and are investigated using particle-in-cell (PIC) simulations. The nonlinear dynamics are significantly more complicated in the transient SASE regime when compared with the steady state amplifier model due to the slippage of the radiation with respect to the beam. As strong self-bunching of the electron beam develops due to SASE, short pulses of superradiant emission develop with peak powers significantly larger than the predicted saturated power based on the steady state amplifier model. As these superradiant pulses grow, their pulse length decreases and forms a series of soliton-like pulses. Comparisons between the linear theory, macro-particle model, and PIC simulations are

  10. Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Fahimian, Benjamin; Türkcan, Silvan; Kapp, Daniel S.; Pratx, Guillem, E-mail: pratx@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States); Ceballos, Andrew [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

  11. Radiation hardness of polysiloxane scintillators analyzed by ion beam induced luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Quaranta, A., E-mail: quaranta@ing.unitn.i [University of Trento, Dipartimento di Ingegneria dei Materiali e delle Tecnologie Industriali - DIMTI, Via Mesiano 77, I-38050 Povo, Trento (Italy); INFN, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy); Carturan, S. [Universita di Padova, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy); Marchi, T.; Antonaci, A. [INFN, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy); Scian, C. [Universita di Padova, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy); Kravchuk, V.L. [Universita di Bologna, Dipartimento di Fisica, Viale Carlo Berti Pichat 6, I-40127 Bologna (Italy); Degerlier, M.; Gramegna, F. [INFN, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy); Maggioni, G. [Universita di Padova, Laboratori Nazionali di Legnaro, Via dell' Universita 2, I-35020 Legnaro, Padova (Italy)

    2010-10-01

    The radiation hardness of polysiloxane based scintillators has been measured by ion beam induced luminescence (IBIL). The light intensity as a function of the irradiation fluence with an He{sup +} beam at 1.8 MeV (1.0 {mu}A/cm{sup 2}) has been measured on undoped polymers synthesized with different amounts of phenyl units and on polysiloxanes doped with two different dye molecules (BBOT and Lumogen Violet) sensitizing the scintillation yield.

  12. Noninvasive measurement of micron electron beam size of high energy using diffraction radiation

    CERN Document Server

    Naumenko, G A

    2003-01-01

    Treatments of the usage of diffraction radiation from the relativistic electrons moving though a conductive slit for the transverse beam size measurement encounter hard limitation of the method sensitivity for the electron energy larger than 1 GeV. We consider in this article a possibility of application of the artificial phase shift, which can take place when transverse electron position varies. This allows us to realize the measurements of transverse size of supper-relativistic electron beams with the small emittance.

  13. Radiation protection: protection of patients undergoing cone beam computed tomography examinations.

    Science.gov (United States)

    Drage, Nicholas; Carmichael, Fiona; Brown, Jackie

    2010-10-01

    Cone beam computed tomography is becoming a popular imaging modality in dentistry. The effective dose from these examinations is generally higher than conventional plain film radiography. This article outlines the ways of protecting patients from the harmful effects of radiation. Cone beam computed tomography is an emerging imaging modality. The effective doses are generally higher than conventional radiography and it is therefore important that anyone requesting or performing these investigations understands how to keep the doses to patients as low as reasonably practicable.

  14. Accurate and Fast Localization of Prostate for External Beam Radiation Therapy

    Science.gov (United States)

    2009-03-01

    kilovoltage cone-beam computed tomography in radiation therapy”, oral presentation in 2008 AAPM Annual Meeting, (selected for long presentation at...dose x- ray fluoroscopy”, poster presentation in 2008 AAPM Annual Meeting, Houston, TX 6. L. Zhu, J. Wang, Y. Xie, J. Starman, R. Fahrig, and L. Xing...A patient set-up protocol based on partially blocked cone-beam CT”, poster presentation in 2008 AAPM Annual Meeting, Houston, TX 7. J. Wang, T

  15. Betatron radiation based diagnostics for plasma wakefield accelerated electron beams at the SPARC-LAB test facility

    Energy Technology Data Exchange (ETDEWEB)

    Shpakov, V.; Anania, M.P.; Biagioni, A.; Chiadroni, E. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Cianchi, A. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); “Tor Vergata” University, via della Ricerca Scientifica 1, 00133 Rome (Italy); Curcio, A. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Dabagov, S. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); P.N. Lebedev Physical Institute RAS, Leninskiy Prospekt 53, 119991 Moscow (Russian Federation); NRNU “MEPhI”, Kashirskoe highway 31, 115409 Moscow (Russian Federation); Ferrario, M.; Filippi, F. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Marocchino, A. [Dipartimento SBAI Universitá di Roma ‘La Sapienza’, via Antonio Scarpa 14/16, 00161 Rome (Italy); Paroli, B. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Pompili, R. [INFN - LNF, via Enrico Fermi 40, 00044 Frascati (Italy); Rossi, A.R. [INFN - MI, via Celoria 16, 20133 Milan (Italy); Zigler, A. [Racah Institute of Physics Hebrew University of Jerusalem (Israel)

    2016-09-01

    Recent progress with wake-field acceleration has shown a great potential in providing high gradient acceleration fields, while the quality of the beams remains relatively poor. Precise knowledge of the beam size at the exit from the plasma and matching conditions for the externally injected beams are the key for improvement of beam quality. Betatron radiation emitted by the beam during acceleration in the plasma is a powerful tool for the transverse beam size measurement, being also non-intercepting. In this work we report on the technical solutions chosen at SPARC-LAB for such diagnostics tool, along with expected parameters of betatron radiation. - Highlights: • The betatron radiation parameters in SPARC-LAB wakefiled experiments were studied. • The differences with betatron radiation in other wake-field experiments were highlighted. • The solution for betatron radiation detection was investigated.

  16. Coherent Terahertz Radiation from Multiple Electron Beams Excitation within a Plasmonic Crystal-like structure

    Science.gov (United States)

    Zhang, Yaxin; Zhou, Yucong; Gang, Yin; Jiang, Guili; Yang, Ziqiang

    2017-01-01

    Coherent terahertz radiation from multiple electron beams excitation within a plasmonic crystal-like structure (a three-dimensional holes array) which is composed of multiple stacked layers with 3 × 3 subwavelength holes array has been proposed in this paper. It has been found that in the structure the electromagnetic fields in each hole can be coupled with one another to construct a composite mode with strong field intensity. Therefore, the multiple electron beams injection can excite and efficiently interact with such mode. Meanwhile, the coupling among the electron beams is taken place during the interaction so that a very strong coherent terahertz radiation with high electron conversion efficiency can be generated. Furthermore, due to the coupling, the starting current density of this mechanism is much lower than that of traditional electron beam-driven terahertz sources. This multi-beam radiation system may provide a favorable way to combine photonics structure with electronics excitation to generate middle, high power terahertz radiation.

  17. Diagnostics of Electron Beams Based on Cherenkov Radiation in an Optical Fiber

    Science.gov (United States)

    Vukolov, A. V.; Novokshonov, A. I.; Potylitsyn, A. P.; Uglov, S. R.

    2017-02-01

    The use of an optical fiber in which Cherenkov radiation is generated instead of a metal wire for scanning a beam profile allows a compact and noise-proof device for diagnostics of charged particle beams in a wide energy range to be developed. Results of experimental investigation of the yield of Vavilov-Cherenkov radiation generated in optical fibers with thickness in the range from 0.125 to 1 mm by electrons with energy of 5.7 MeV are presented.

  18. Vagus nerve stimulator stability and interference on radiation oncology x-ray beams

    Science.gov (United States)

    Gossman, Michael S.; Ketkar, Amruta; Liu, Arthur K.; Olin, Bryan

    2012-10-01

    Five different models of Cyberonics, Inc. vagus nerve stimulation (VNS) therapy pulse generators were investigated for their stability under radiation and their ability to change the absorbed dose from incident radiation. X-ray beams of 6 MV and 18 MV were used to quantify these results up to clinical doses of 68-78 Gy delivered in a single fraction. In the first part, the effect on electronic stimulation signaling of each pulse generator was monitored during and immediately afterwards with computer interrogation. In the second part, the effects of having the pulse generators scatter or attenuate the x-ray beam was also characterized from dose calculations on a treatment planning system as well as from actual radiation measurements. Some device models were found to be susceptible to radiation interference when placed directly in the beam of high energy therapeutic x-ray radiation. While some models exhibited no effect at all, others showed an apparent loss of stimulation output immediately after radiation was experienced. Still, other models were observed to have a cumulative dose effect with a reduced output signal, followed by battery depletion above 49 Gy. Absorbed dose changes on computer underestimated attenuation by nearly half for both energies amongst all pulse generators, although the computer did depict the proper shape of the changed distribution of dose around the device. Measured attenuation ranged from 7.0% to 11.0% at 6 MV and 4.2% to 5.2% at 18 MV for x-rays. Processes of back-scatter and side-scatter were deemed negligible although recorded. Identical results from 6 MV and 18 MV x-ray beams conclude no neutron effect was induced for the 18 MV beam. As there were documented effects identified in this research regarding pulse generation, it emphasizes the importance of caution when considering radiation therapy on patients with implanted VNS devices with observed malfunctions consequential.

  19. Impact of Monoenergetic Photon Sources on Nonproliferation Applications Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Geddes, Cameron [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ludewigt, Bernhard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Valentine, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Quiter, Brian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Descalle, Marie-Anne [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Warren, Glen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kinlaw, Matt [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thompson, Scott [Idaho National Lab. (INL), Idaho Falls, ID (United States); Chichester, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, Cameron [Univ. of Michigan, Ann Arbor, MI (United States); Pozzi, Sara [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-01

    Near-monoenergetic photon sources (MPSs) have the potential to improve sensitivity at greatly reduced dose in existing applications and enable new capabilities in other applications, particularly where passive signatures do not penetrate or are insufficiently accurate. MPS advantages include the ability to select energy, energy spread, flux, and pulse structures to deliver only the photons needed for the application, while suppressing extraneous dose and background. Some MPSs also offer narrow angular divergence photon beams which can target dose and/or mitigate scattering contributions to image contrast degradation. Current bremsstrahlung photon sources (e.g., linacs and betatrons) produce photons over a broad range of energies, thus delivering unnecessary dose that in some cases also interferes with the signature to be detected and/or restricts operations. Current sources must be collimated (reducing flux) to generate narrow divergence beams. While MPSs can in principle resolve these issues, they remain at relatively low TRL status. Candidate MPS technologies for nonproliferation applications are now being developed, each of which has different properties (e.g. broad vs. narrow angular divergence). Within each technology, source parameters trade off against one another (e.g. flux vs. energy spread), representing a large operation space. This report describes a broad survey of potential applications, identification of high priority applications, and detailed simulations addressing those priority applications. Requirements were derived for each application, and analysis and simulations were conducted to define MPS parameters that deliver benefit. The results can inform targeting of MPS development to deliver strong impact relative to current systems.

  20. Effects of transverse electron beam size on transition radiation angular distribution

    Energy Technology Data Exchange (ETDEWEB)

    Chiadroni, E., E-mail: enrica.chiadroni@lnf.infn.it [Laboratori Nazionali di Frascati-INFN, via E. Fermi, 40, 00044 Frascati (Italy); Castellano, M. [Laboratori Nazionali di Frascati-INFN, via E. Fermi, 40, 00044 Frascati (Italy); Cianchi, A. [University of Rome ' Tor Vergata' and INFN-Tor Vergata, Via della Ricerca Scientifica 1, 00133 Rome (Italy); Honkavaara, K.; Kube, G. [Deutsches Elektronen-Synchrotron, Notkestrasse 85, 22607 Hamburg (Germany)

    2012-05-01

    In this paper we consider the effect of the transverse electron beam size on the Optical Transition Radiation (OTR) angular distribution in case of both incoherent and coherent emission. Our results confute the theoretical argumentations presented first in Optics Communications 211, 109 (2002), which predicts a dependence of the incoherent OTR angular distribution on the beam size and emission wavelength. We present here theoretical and experimental data not only to validate the well-established Ginzburg-Frank theory, but also to show the impact of the transverse beam size in case of coherent emission.

  1. Overview of non-intercepting beam-size monitoring with optical diffraction radiation

    CERN Document Server

    Lumpkin, Alex H

    2012-01-01

    The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as non-intercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.

  2. Electron Beam Spectrum Diagnostics with Optical Transition Radiation on the Beijing Free-Electron Laser

    Institute of Scientific and Technical Information of China (English)

    李泉凤; 吴频; 高建江; 吴刚

    2004-01-01

    A measurement system was developed to measure the electron beam spectrum of the Beijing free-electron laser based on the optical transition radiation (OTR). This paper describes the system, which consists of a 32-channel high resolution of 0.02% OTR detector, especially the spectrometer. The OTR angular-distribution pattern at the focal plane has two apexes, but the two apexes are smoothed out due to the electron beam energy distribution. The energy spectrum can be measured if the magnet energy resolution is higher than 0.7% to distinguish the electron beam energy distribution.

  3. Overview of nonintercepting beam-size monitoring with optical diffraction radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, Alex H.; /Fermilab

    2010-08-01

    The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as nonintercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.

  4. Beam conditions for radiation generated by an electromagnetic Hermite-Gaussian model source

    Institute of Scientific and Technical Information of China (English)

    LI Jia; XIN Yu; CHEN Yan-ru

    2011-01-01

    @@ Within the framework of the correlation theory of electromagnetic laser beams, the far field cross-spectral density matrix of the light radiated from an electromagnetic Hermite-Gaussian model source is derived.By utilizing the convergence property of Hermite polynomials, the conditions of the matrices for the source to generate an electromagnetic Hermite-Gaussian beam are obtained.Furthermore, in order to generate a scalar Hermite-Gaussian model beam, it is required that the source should be locally rather coherent in the spatial domain.

  5. Ultrafast Radiation Detection by Modulation of an Optical Probe Beam

    Energy Technology Data Exchange (ETDEWEB)

    Vernon, S P; Lowry, M E

    2006-02-22

    We describe a new class of radiation sensor that utilizes optical interferometry to measure radiation-induced changes in the optical refractive index of a semiconductor sensor medium. Radiation absorption in the sensor material produces a transient, non-equilibrium, electron-hole pair distribution that locally modifies the complex, optical refractive index of the sensor medium. Changes in the real (imaginary) part of the local refractive index produce a differential phase shift (absorption) of an optical probe used to interrogate the sensor material. In contrast to conventional radiation detectors where signal levels are proportional to the incident energy, signal levels in these optical sensors are proportional to the incident radiation energy flux. This allows for reduction of the sensor form factor with no degradation in detection sensitivity. Furthermore, since the radiation induced, non-equilibrium electron-hole pair distribution is effectively measured ''in place'' there is no requirement to spatially separate and collect the generated charges; consequently, the sensor risetime is of the order of the hot-electron thermalization time {le} 10 fs and the duration of the index perturbation is determined by the carrier recombination time which is of order {approx} 600 fs in, direct-bandgap semiconductors, with a high density of recombination defects; consequently, the optical sensors can be engineered with sub-ps temporal response. A series of detectors were designed, and incorporated into Mach Zehnder and Fabry-Perot interferometer-based detection systems: proof of concept, lower detection sensitivity, Mach-Zehnder detectors were characterized at beamline 6.3 at SSRL; three generations of high sensitivity single element and imaging Fabry-Perot detectors were measured at the LLNL Europa facility. Our results indicate that this technology can be used to provide x-ray detectors and x-ray imaging systems with single x-ray sensitivity and S

  6. Evidence for anomalous optical transition radiation linear polarization effects in beam-profile monitors

    Directory of Open Access Journals (Sweden)

    A. H. Lumpkin

    2013-10-01

    Full Text Available Investigations of the effects of optical transition radiation (OTR polarization components on beam profiles are presented. The transverse profiles are examined using the OTR perpendicular and parallel polarization components with respect to the dimension of interest. We observed ∼15% projected profile size reductions with the perpendicularly polarized components on a 65-μm beam image size case at 14 MeV, a 150-μm beam image size at 4.5 GeV, and a 1100-μm beam image size at 7 GeV. These effects are all several times larger than expected (and anomalous in this sense when compared to the standard OTR point-spread function calculations. We propose the time-averaged induced-current distribution which generates the OTR represents the actual beam size more faithfully with the perpendicular polarization component and recommend its routine use and subsequent deconvolution.

  7. Calculation of radiation acoustical fields from phased arrays with nonparaxial multi-Gaussian beam model

    Institute of Scientific and Technical Information of China (English)

    ZHAO Xinyu; GANG Tie; ZHANG Bixing

    2009-01-01

    A nonparaxial multi-Gaussian beam model based on the rectangular aperture is proposed in order to overcome the hmitation of paraxial Gaussian beam model which losing accuracy in off-axis beam fields. With the method, acoustical field generated by an ultra-sonic linear phased array transducer is calculated and compared with the corresponding field obtained by Rayleigh-Sommerfeld integral, paraxial multi-Gaussian beam model, and Fraunhof-fer approximation method. Simulation examples show that nonparaxial multi-Gaussian beam model is not limited by the paraxial approximation condition and can predict efficiently and accurately the acoustical field radiated by a linear phased array transducer over a wide range of steering angles.

  8. ELBE Center for High-Power Radiation Sources

    Directory of Open Access Journals (Sweden)

    Peter Dr. Michel

    2016-01-01

    Full Text Available In the ELBE Center for High-Power Radiation Sources, the superconducting linear electron accelerator ELBE, serving  two free electron lasers, sources for intense coherent THz radiation, mono-energetic positrons, electrons, γ-rays, a neutron time-of-flight system as well as two synchronized ultra-short pulsed Petawatt laser systems are collocated. The characteristics of these beams make the ELBE center a unique research instrument for a variety of external users in fields ranging from material science over nuclear physics to cancer research, as well as scientists of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR.

  9. High-current CW beam profile monitors using transition radiation at CEBAF

    Science.gov (United States)

    Piot, P.; Denard, J.-C.; Adderley, P.; Capek, K.; Feldl, E.

    1997-01-01

    One way of measuring the profile of CEBAF's low-emittance, high-power beam is to use the optical transition radiation (OTR) emitted from a thin foil surface when the electron beam passes through it. We present the design of a monitor using the forward OTR emitted from a 0.25-μm carbon foil. We believe that the monitor will resolve three main issues: i) whether the maximum temperature of the foil stays below the melting point, ii) whether the beam loss remains below 0.5%, in order not to trigger the machine protection system, and iii) whether the monitor resolution (unlike that of synchrotron radiation monitors) is better than the product λγ. It seems that the most serious limitation for CEBAF is the beam loss due to beam scattering. We present results from Keil's theory and simulations from the computer code GEANT as well as measurements with aluminum foils with a 45-MeV electron beam. We also present a measurement of a 3.2-GeV beam profile that is much smaller than λγ, supporting Rule and Fiorito's calculations of the OTR resolution limit due to diffraction.

  10. Enhancement of FEM radiation by prebunching of the e-beam (stimulated super-radiance)

    CERN Document Server

    Arbel, M; Kleinman, H; Yakover, I M; Abramovich, A; Pinhasi, Y; Luria, Y; Tecimer, M; Gover, A

    2001-01-01

    An electron beam (e-beam) prebunched at the synchronous FEM frequency and traversing through a waveguide, located coaxially with a magnetic undulator, emits coherent radiation at the bunching frequency. Introduction of both a premodulated e-beam and a radio-frequency (r.f.) signal at the same frequency at the input of the waveguide can lead to more efficient interaction, and thus more power can be extracted from the electron beam. In order to achieve this, the density modulation of the electron beam should be at an appropriate phase with respect to the r.f. signal. We report a first experimental demonstration of the influence of the phase difference between the r.f. input signal and the fundamental component of the density modulation of the e-beam on the radiated power in a Free-Electron Maser (FEM). Our experimental system allows control of the current density modulation, of the r.f. input power level, in the undulator region and of the phase between that r.f. input and the modulation of the e-beam. A compar...

  11. Principles of longitudinal beam diagnostics with coherent radiation

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, O.; Schmueser, P.

    2006-04-24

    The FLASH facility requires novel techniques to characterize the longitudinal charge distribution of the electron bunches that drive the free-electron laser. Bunch features well below 30 {mu}m need to be resolved. One technique is based on the measurement of the far-infrared radiation spectrum and reconstruction of the bunch shape through Fourier analysis. Currently, experiments using synchrotron, transition and diffraction radiation are operating at FLASH, studying the emission spectra with various instruments. This report describes the basic physics, the measurement principles, and gives explicit mathematical derivations. References to more comprehensive discussions of practical problems and experiments are listed. After a brief introduction in Sect. 1, the radiation spectrum emitted by an electron bunch is calculated in Sect. 2 in far-field approximation. The technique to reconstruct the bunch shape from the spectrum and its basic limitations are then explained in Sect. 3. Practical examples are given. The typical radiation pulse duration ranges from less than 100 femtoseconds to several picoseconds. (orig.)

  12. Experimental and theoretical investigation of microwave and millimeter wave radiation from hollow, rotating, electron beams

    Science.gov (United States)

    Destler, W. W.; Weiler, R. L.; Striffler, C. D.

    1981-11-01

    During this period this effort has explored the scaling of the negative mass instability to regimes associated with smaller plasmas and short wavelengths for the plasma-produced radiation. An experimental apparatus for these studies is near completion. The nonlinear electromagnetic interaction between the collective/bunches of electrons and the radiation field has been formulated in an attempt to derive the efficiency of the production of radiation. In addition, the Dragon electron beam source is currently being improved for future radiation production experiments based on the negative mass instability. Experimental efforts at high powers have resulted in the enhancement of radiation at a single frequency. This last effort has utilized a "double-magnetron cavity' to enhance the radiation power in Ka band at 26 and 41GHz.

  13. Alanine Radiation Detectors in Therapeutic Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo;

    of the depth dose curves. Solid state detectors, such as diamond detectors, radiochromic films, TLDs and the amino acid alanine are used due to there good spatial resolution. If used in particle beams their response often exhibits a dependence on particle energy and type, so the acquired signal is not always...... at energies below 20 MeV/u. We implemented this model in the Monte Carlo code FLUKA. At the GSI heavy ion facility in Darmstadt, Germany, alanine has been irradiated with carbon ions at energies between 88 an 400 MeV/u, which is the energy range used for therapy. The irradiation and the detector response have...

  14. Separated high-energy electron beams using synchrotron radiation

    CERN Document Server

    Farley, F J M; Picasso, Emilio

    1972-01-01

    Electrons with kinetic energy in the 100 GeV range may be separated from other particles by using their energy-loss due to synchrotron radiation in a high-field magnet. In this paper the associated fluctuations in energy and angle are shown to be small enough for the method to be useful. Detailed design formulae are presented for several magnet configurations. (7 refs).

  15. Cherenkov imaging during volumetric modulated arc therapy for real-time radiation beam tracking and treatment response monitoring

    Science.gov (United States)

    Andreozzi, Jacqueline M.; Zhang, Rongxiao; Glaser, Adam K.; Gladstone, David J.; Jarvis, Lesley A.; Pogue, Brian W.

    2016-03-01

    External beam radiotherapy utilizes high energy radiation to target cancer with dynamic, patient-specific treatment plans. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high energy beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to track the radiation beam on the surface of the patient in real-time, even for complex cases such as volumetric modulated arc therapy (VMAT). Two patients undergoing VMAT of the head and neck were imaged and analyzed, and the viability of the system to provide clinical feedback was established.

  16. Echo-enabled tunable terahertz radiation generation with a laser-modulated relativistic electron beam

    Directory of Open Access Journals (Sweden)

    Zhen Wang

    2014-09-01

    Full Text Available A new scheme to generate narrow-band tunable terahertz (THz radiation using a variant of the echo-enabled harmonic generation is analyzed. We show that by using an energy chirped beam, THz density modulation in the beam phase space can be produced with two lasers having the same wavelength. This removes the need for an optical parametric amplifier system to provide a wavelength-tunable laser to vary the central frequency of the THz radiation. The practical feasibility and applications of this scheme are demonstrated numerically with a start-to-end simulation using the beam parameters at the Shanghai Deep Ultraviolet Free-Electron Laser facility (SDUV. The central frequency of the density modulation can be continuously tuned by either varying the chirp of the beam or the momentum compactions of the chicanes. The influence of nonlinear rf chirp and longitudinal space charge effect have also been studied in our article. The methods to generate the THz radiation in SDUV with the new scheme and the estimation of the radiation power are also discussed briefly.

  17. Radiative instability of a relativistic electron beam moving in a photonic crystal

    CERN Document Server

    Baryshevsky, V G

    2010-01-01

    The radiative instability of a beam moving in a photonic crystal of finite dimensions is studied. The dispersion equation is obtained. The law $\\Gamma\\sim \\rho ^{1/\\left( {s + 3} \\right)}$ is shown to be valid and caused by the mixing of the electromagnetic field modes in the finite volume due to the periodic disturbance from the photonic crystal.

  18. Radiative instability of a relativistic electron beam moving in a photonic crystal

    OpenAIRE

    Baryshevsky, V.G.; Gurinovich, A. A.

    2013-01-01

    The radiative instability of a beam moving in a photonic crystal of finite dimensions is studied. The dispersion equation is obtained. The law $\\Gamma\\sim \\rho ^{1/\\left( {s + 3} \\right)}$ is shown to be valid and caused by the mixing of the electromagnetic field modes in the finite volume due to the periodic disturbance from the photonic crystal.

  19. Enhanced coherent emission of terahertz radiation by energy-phase correlation in a bunched electron beam.

    Science.gov (United States)

    Doria, A; Gallerano, G P; Giovenale, E; Messina, G; Spassovsky, I

    2004-12-31

    We report the first observation of enhanced coherent emission of terahertz radiation in a compact free electron laser. A radio-frequency (rf) modulated electron beam is passed through a magnetic undulator emitting coherent radiation at harmonics of the rf with a phase which depends on the electron drift velocity. A proper correlation between the energy and phase distributions of the electrons in the bunch has been exploited to lock in phase the radiated field, resulting in over 1 order of magnitude enhancement of the coherent emission.

  20. Terahertz coherent transition radiation based on an ultrashort electron bunching beam

    Science.gov (United States)

    Liu, Wen-Xin; Huang, Wen-Hui; Du, Ying-Chao; Yan, Li-Xin; Wu, Dai; Tang, Chuan-Xiang

    2011-07-01

    The experimental result of terahertz (THz) coherent transition radiation generated from an ultrashort electron bunching beam is reported. During this experiment, the window for THz transmission from ultrahigh vacuum to free air is tested. The compact measurement system which can simultaneously test the THz wave power and frequency is built and proofed. With the help of improved Martin—Puplett interferometer and Kramers—Krong transform, the longitudinal bunch length is measured. The results show that the peak power of THz radiation wave is more than 80 kW, and its radiation frequency is from 0.1 THz to 1.5 THz.

  1. A novel method involving Matlab coding to determine the distribution of a collimated ionizing radiation beam

    Science.gov (United States)

    Ioan, M.-R.

    2016-08-01

    In ionizing radiation related experiments, precisely knowing of the involved parameters it is a very important task. Some of these experiments are involving the use of electromagnetic ionizing radiation such are gamma rays and X rays, others make use of energetic charged or not charged small dimensions particles such are protons, electrons, neutrons and even, in other cases, larger accelerated particles such are helium or deuterium nuclei are used. In all these cases the beam used to hit an exposed target must be previously collimated and precisely characterized. In this paper, a novel method to determine the distribution of the collimated beam involving Matlab coding is proposed. The method was implemented by using of some Pyrex glass test samples placed in the beam where its distribution and dimension must be determined, followed by taking high quality pictures of them and then by digital processing the resulted images. By this method, information regarding the doses absorbed in the exposed samples volume are obtained too.

  2. Refractive lenses as a beam diagnostics tool for high-energy synchrotron radiation

    CERN Document Server

    Weitkamp, T; Drakopoulos, M; Souvorov, A; Snigireva, I; Snigirev, A; Guenzler, F; Schrör, C; Lengeler, B

    2001-01-01

    Parabolic compound refractive lenses (CRLs) for hard X rays have been used to image the electron beam at undulator and bending-magnet beamlines at the ESRF. The measurements yield the shape and size of the synchrotron radiation source, and show that CRLs with paraboloid surface shape can be used as a beam diagnostics tool at high-energy electron storage rings. The optical resolution of the imaging setup can be as small as 4 mu m. This is smaller than typical values of the electron beam size in third-generation synchrotron sources. We report measurements at two ESRF beamlines and resolution calculations taking into account the properties of synchrotron radiation and the transmission characteristics of the CRLs used.

  3. The Performance of the Beam Conditions and Radiation Monitoring System of CMS

    CERN Document Server

    Dabrowski, Anne

    2011-01-01

    The Beam Conditions and Radiation Monitoring System (BRM), is installed in CMS to protect the CMS detector from high beam losses and to provide feedback to the LHC and CMS on the beam conditions. The primary detector sub-systems are based on either single crystal diamond sensors (BCM1F) for particle counting with nanosecond resolution or on polycrystalline diamonds (BCM2; BCM1L) for integrated signal current measurements. Beam scintillation counters (BSC) are also used during low luminosity running. The detectors have radiation hard front-end electronics and are read out independently of the CMS central data acquisition and are online whenever there is beam in the LHC machine. The various sub-systems exploit different time resolutions and position locations to be able to monitor the beam induced backgrounds and the flux of particles produced during collisions. This paper describes the CMS BRM system and the complementary aspects of the installed BRM sub-detectors to measure both single particle count rates a...

  4. Analysis of Radiation Beam of a Leaky Lamb Wave in Ultrasonic Waveguide Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Y. S.; Bae, J. H.; Park, C. G.; Lee, J. H.

    2010-02-15

    The theoretical and experimental study of the propagation and radiation of leaky Lamb wave in a plate waveguide sensor has been carried out. In the plate waveguide sensor, the A{sub 0} leaky Lamb wave is utilized for the single mode generation and the effective radiation capability in a fluid. The plate waveguide sensor which consists of a plate waveguide, a teflon wedge and an ultrasonic sensor has been designed and manufactured. The tone-burst excitation of high power long pulse should be applied to minimize the dispersion effect in 10 m long distance propagation of the A{sub 0} Lamb wave. A novel technique which is capable of steering a radiation beam of a waveguide sensor without a mechanical movement can be achieved by a frequency tuning method of the excitation pulse in the dispersive low frequency range of the A{sub 0} Lamb wave. The characteristics of radiation beam of ultrasonic waveguide sensors has been investigated by the beam profile measurements according to the plate thickness, the radiation aperture length, the pulse cycles and the excitation frequency. The design parameters of the plate waveguide sensor has been optimized. The C-scanning experiments in water have been carried out for the performance of the optimized ultrasonic waveguide sensor. The poulsbility of C-scan visualization using the plate waveguide sensor has been verified

  5. Shielding NSLS-II light source: Importance of geometry for calculating radiation levels from beam losses

    Science.gov (United States)

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.; Wahl, W.

    2016-11-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produces significantly higher neutron component dose to the experimental floor than a lower energy beam injection and ramped operations. Minimizing this dose will require adequate knowledge of where the miss-steered beam can occur and sufficient EM shielding close to the loss point, in order to attenuate the energy of the particles in the EM shower below the neutron production threshold (Designing supplemental shielding near the loss point using the analytic shielding model is shown to be inadequate because of its lack of geometry specification for the EM shower process. To predict the dose rates outside the tunnel requires detailed description of the geometry and materials that the beam losses will encounter inside the tunnel. Modern radiation shielding Monte-Carlo codes, like FLUKA, can handle this geometric description of the radiation transport process in sufficient detail, allowing accurate predictions of the dose rates expected and the ability to show weaknesses in the design before a high radiation incident occurs. The effort required to adequately define the accelerator geometry for these codes has been greatly reduced with the implementation of the graphical interface of FLAIR to FLUKA. This made the effective shielding process for NSLS-II quite accurate and reliable. The principles used to provide supplemental shielding to the NSLS-II accelerators and the lessons learned from this process are presented.

  6. Quantum radiation reaction in head-on laser-electron beam interaction

    CERN Document Server

    Vranic, Marija; Fonseca, Ricardo A; Silva, Luis O

    2015-01-01

    In this paper, we investigate the evolution of the energy spread and the divergence of electron beams while they interact with different laser pulses at intensities where quantum effects and radiation reaction are of relevance. The interaction is modeled with a QED-PIC code and the results are compared with those obtained with a standard PIC code with the addition of a classical radiation reaction module and with theoretical predictions. While classical radiation reaction is a continuous process, in QED, radiation emission is stochastic. The two pictures reconcile in the limit when the emitted photons energy is small compared to the energy of the emitting electrons. The energy spread of the electron distribution function always tends to decrease with classical radiation reaction, whereas the stochastic QED emission can also enlarge it. These two tendencies compete in the QED-dominated regime. Our analysis, supported by the QED module, reveals an upper limit to the maximal attainable energy spread due to stoch...

  7. Detector Response and Beam Line Transmission Measurements with Far-Infrared Radiation

    CERN Document Server

    Grimm, O; Fröhlich, L

    2005-01-01

    Various activities at the TTF linear accelerator at DESY, Hamburg, that drives the VUV-FEL are geared towards measuring the longitudinal charge distribution of electron bunches with coherent far-infrared radiation. Examples are beam lines transporting synchrotron or transition radiation to interferometers mounted inside or outside the tunnel, and studies of single-shot grating spectrometers. All such approaches require a good understanding of the radiation generation and transport mechanism and of the detector characteristics to extract useful information on the charge distribution. Simulations and measurements of the expected transverse intensity distribution and polarization of synchrotron radiation emitted at the first bunch compressor of TTF have been performed. The transverse intensity scanning provided for the first time at DESY a visual image of the footprint of terahertz radiation. Detector response measurements have been performed at the FELIX facility, Netherlands, for wavelengths between 100-160 mi...

  8. Electromagnetic radiation and nonlinear energy flow in an electron beam-plasma system

    Science.gov (United States)

    Whelan, D. A.; Stenzel, R. L.

    1985-01-01

    It is shown that the unstable electron-plasma waves of a beam-plasma system can generate electromagnetic radiation in a uniform plasma. The generation mechanism is a scattering of the unstable electron plasma waves off ion-acoustic waves, producing electromagnetic waves whose frequency is near the local plasma frequency. The wave vector and frequency matching conditions of the three-wave mode coupling are experimentally verified. The electromagnetic radiation is observed to be polarized with the electric field parallel to the beam direction, and its source region is shown to be localized to the unstable plasma wave region. The frequency spectrum shows negligible intensity near the second harmonic of the plasma frequency. These results suggest that the observed electromagnetic radiation of type III solar bursts may be generated near the local plasma frequency and observed downstream where the wave frequency is near the harmonic of the plasma frequency.

  9. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  10. Electromagnetic Coupling Between High Intensity LHC Beams and the Synchrotron Radiation Monitor Light Extraction System

    CERN Document Server

    Andreazza, W; Bravin, E; Caspers, F; Garlasch`e, M; Gras, J; Goldblatt, A; Lefevre, T; Jones, R; Metral, E; Nosych, A; Roncarolo_, F; Salvant, B; Trad, G; Veness, R; Vollinger, C; Wendt, M

    2013-01-01

    The CERN LHC is equipped with two Synchrotron Radiation Monitor (BSRT) systems used to characterise transverse and longitudinal beam distributions. Since the end of the 2011 LHC run the light extraction system, based on a retractable mirror, has suffered deformation and mechanical failure that is correlated to the increase in beam intensity. Temperature probes have associated these observations to a strong heating of the mirror support with a dependence on the longitudinal bunch length and shape, indicating the origin as electromagnetic coupling between the beam and the structure. This paper combines all this information with the aim of characterising and improving the system in view of its upgrade during the current LHC shutdown. Beam-based observations are presented along with electromagnetic and thermomechanical simulations and complemented by laboratory measurements, including the study of the RF properties of different mirror bulk and coating materials.

  11. Monte Carlo feasibility study of orthogonal bremsstrahlung beams for improved radiation therapy imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jabbari, Keyvan; Sarfehnia, Arman; Podgorsak, Ervin B; Seuntjens, Jan P [Medical Physics Unit, McGill University, Montreal General Hospital, 1650 avenue Cedar, Montreal, Quebec H3G 1A4 (Canada)

    2007-02-21

    an improvement of the contrast for lower Z target materials. This study confirms the feasibility, both in terms of intensity and image contrast, of orthogonal bremsstrahlung beams for radiation therapy imaging.

  12. Monte Carlo feasibility study of orthogonal bremsstrahlung beams for improved radiation therapy imaging

    Science.gov (United States)

    Jabbari, Keyvan; Sarfehnia, Arman; Podgorsak, Ervin B.; Seuntjens, Jan P.

    2007-02-01

    improvement of the contrast for lower Z target materials. This study confirms the feasibility, both in terms of intensity and image contrast, of orthogonal bremsstrahlung beams for radiation therapy imaging.

  13. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  14. OVERVIEW OF MONO-ENERGETIC GAMMA-RAY SOURCES & APPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Hartemann, F V; Albert, F; Anderson, G G; Anderson, S G; Bayramian, A J; Betts, S M; Chu, T S; Cross, R R; Ebbers, C A; Fisher, S E; Gibson, D J; Ladran, A S; Marsh, R A; Messerly, M J; O' Neill, K L; Semenov, V A; Shverdin, M Y; Siders, C W; McNabb, D P; Barty, C P; Vlieks, A E; Jongewaard, E N; Tantawi, S G; Raubenheimer, T O

    2010-05-18

    Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable Mono-Energetic Gamma-ray (MEGa-ray) source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC NAL will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. This MEGa-ray source will be used to excite nuclear resonance fluorescence in various isotopes. Applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented, along with important applications, including nuclear resonance fluorescence. In conclusion, we have optimized the design of a high brightness Compton scattering gamma-ray source, specifically designed for NRF applications. Two different parameters sets have been considered: one where the number of photons scattered in a single shot reaches approximately 7.5 x 10{sup 8}, with a focal spot size around 8 {micro}m; in the second set, the spectral brightness is optimized by using a 20 {micro}m spot size, with 0.2% relative bandwidth.

  15. LASER TECHNOLOGY FOR PRECISION MONOENERGETIC GAMMA-RAY SOURCE R&D AT LLNL

    Energy Technology Data Exchange (ETDEWEB)

    Shverdin, M Y; Bayramian, A; Albert, F; Anderson, S G; Betts, S M; Chu, T S; Cross, R R; Gibson, D J; Marsh, R; Messerly, M; Phan, H; Prantil, M; Wu, S; Ebbers, C; Scarpetti, R D; Hartemann, F V; Siders, C W; McNabb, D P; Bonanno, R E; Barty, C P

    2010-04-20

    Generation of mono-energetic, high brightness gamma-rays requires state of the art lasers to both produce a low emittance electron beam in the linac and high intensity, narrow linewidth laser photons for scattering with the relativistic electrons. Here, we overview the laser systems for the 3rd generation Monoenergetic Gamma-ray Source (MEGa-ray) currently under construction at Lawrence Livermore National Lab (LLNL). We also describe a method for increasing the efficiency of laser Compton scattering through laser pulse recirculation. The fiber-based photoinjector laser will produce 50 {micro}J temporally and spatially shaped UV pulses at 120 Hz to generate a low emittance electron beam in the X-band RF photoinjector. The interaction laser generates high intensity photons that focus into the interaction region and scatter off the accelerated electrons. This system utilizes chirped pulse amplification and commercial diode pumped solid state Nd:YAG amplifiers to produce 0.5 J, 10 ps, 120 Hz pulses at 1064 nm and up to 0.2 J after frequency doubling. A single passively mode-locked Ytterbium fiber oscillator seeds both laser systems and provides a timing synch with the linac.

  16. Modeling and control of sound radiation by simply supported and cantilever beam coupled with smart material

    Directory of Open Access Journals (Sweden)

    Vitaly Makarenko

    2007-03-01

    Full Text Available  In this paper forced vibration of the beam due to bonded piezoelectric patch is considered. When an external excitation is applied to the beam, it starts to vibrate, and the resulting acoustic response is predicted from the analytical model, which is based on Bernoulli-Euler theory of beam vibration. Analytical research of the sound radiation by a finite elastic beam is done for criteria based on minimal total sound power level. Helmholtz equation and inhomogeneous differential equation for beam transverse motion defines the solution to this problem. Such solutions were found for boundary conditions of simply supported and cantilever beams. In order to solve the task two analytical methods were used for simply supported beam. The solutions received by Fourier transform and Green functions approach give the very similar results, thus, proving methods reliability. At the case studies the exerted voltage, phase, location and piezoelectric actuator length are varied in order to establish their influence on noise attenuation.

  17. Beam Output Audit results within the EORTC Radiation Oncology Group network.

    Science.gov (United States)

    Hurkmans, Coen W; Christiaens, Melissa; Collette, Sandra; Weber, Damien Charles

    2016-12-15

    Beam Output Auditing (BOA) is one key process of the EORTC radiation therapy quality assurance program. Here the results obtained between 2005 and 2014 are presented and compared to previous results.For all BOA reports the following parameters were scored: centre, country, date of audit, beam energies and treatment machines audited, auditing organisation, percentage of agreement between stated and measured dose.Four-hundred and sixty-one BOA reports were analyzed containing the results of 1790 photon and 1366 electron beams, delivered by 755 different treatment machines. The majority of beams (91.1%) were within the optimal limit of ≤ 3%. Only 13 beams (0.4%; n = 9 electrons; n = 4 photons), were out of the range of acceptance of ≤ 5%. Previous reviews reported a much higher percentage of 2.5% or more of the BOAs with >5% deviation.The majority of EORTC centres present beam output variations within the 3% tolerance cutoff value and only 0.4% of audited beams presented with variations of more than 5%. This is an important improvement compared to previous BOA results.

  18. Transverse phase space mapping of relativistic electron beams using optical transition radiation

    Directory of Open Access Journals (Sweden)

    G. P. Le Sage

    1999-12-01

    Full Text Available Optical transition radiation (OTR has proven to be a versatile and effective diagnostic for measuring the profile, divergence, and emittance of relativistic electron beams with a wide range of parameters. Diagnosis of the divergence of modern high brightness beams is especially well suited to OTR interference (OTRI techniques, where multiple dielectric or metal foils are used to generate a spatially coherent interference pattern. Theoretical analysis of measured OTR and OTRI patterns allows precise measurement of electron beam emittance characteristics. Here we describe an extension of this technique to allow mapping of divergence characteristics as a function of transverse coordinates within a measured beam. We present the first experimental analysis of the transverse phase space of an electron beam using all optical techniques. Comparing an optically masked portion of the beam to the entire beam, we measure different angular spread and average direction of the particles. Direct measurement of the phase-space ellipse tilt angle has been demonstrated using this optical masking technique.

  19. The Role of Beam polarization for Radiative Neutralino Production at the ILC

    CERN Document Server

    Dreiner, H K; Langenfeld, U; Dreiner, Herbert K.; Kittel, Olaf; Langenfeld, Ulrich

    2007-01-01

    We analyze the impact of electron and positron beam polarization on radiative neutralino production at the International Linear Collider (ILC). We focus on three different mSUGRA scenarios in turn at the Higgs strahlung threshold, the top pair production threshold, and at $\\sqrt{s} =500\\GeV$. In these scenarios at the corresponding $\\sqrt{s}$, radiative neutralino production is the only supersymmetric production mechanism which is kinematically allowed. The heavier neutralinos, and charginos as well as the sleptons, squarks and gluinos are too heavy to be pair produced. We calculate the signal cross section and also the Standard Model background from radiative neutrino production. For our scenarios, we obtain significances larger than 10 and signal to background ratios between 2% and 5%, if we have electron beam polarization $P_{e^-} = 0.0- 0.8$ and positron beam polarization $P_{e^+} = 0.0 - 0.3$. If we have electron beam polarization of $P_{e^-} = 0.9$, then the signal is observable with $P_{e^+} = 0.0$ but...

  20. The role of beam polarization for radiative neutralino production at the ILC

    Energy Technology Data Exchange (ETDEWEB)

    Dreiner, H.K.; Kittel, O.; Langenfeld, U. [Physikalisches Institut der Universitaet Bonn, Bonn (Germany)

    2008-03-15

    We analyze the impact of electron and positron beam polarization on radiative neutralino production at the international linear collider (ILC). We focus on three different mSUGRA scenarios in turn at the Higgsstrahlung threshold, the top pair production threshold, and at {radical}(s)=500 GeV. In these scenarios at the corresponding {radical}(s), radiative neutralino production is the only supersymmetric production mechanism that is kinematically allowed. The heavier neutralinos and charginos as well as the sleptons, squarks and gluinos are too heavy to be pair produced. We calculate the signal cross section and also the standard model background from radiative neutrino production. For our scenarios, we obtain significances larger than 10 and signal to background ratios between 2% and 5%, if we have electron beam polarization P{sub e}{sup -}=0.0-0.8 and positron beam polarization P{sub e}{sup +}=0.0-0.3. If we have electron beam polarization of P{sub e}{sup -}=0.9, then the signal is observable with P{sub e}{sup +}=0.0 but both the significance and the signal to background ratio are significantly improved for P{sub e}{sup +}=0.3. (orig.)

  1. The role of beam polarization for radiative neutralino production at the ILC

    Science.gov (United States)

    Dreiner, H. K.; Kittel, O.; Langenfeld, U.

    2008-03-01

    We analyze the impact of electron and positron beam polarization on radiative neutralino production at the international linear collider (ILC). We focus on three different mSUGRA scenarios in turn at the Higgs strahlung threshold, the top pair production threshold, and at sqrt{s} =500 GeV. In these scenarios at the corresponding sqrt{s}, radiative neutralino production is the only supersymmetric production mechanism that is kinematically allowed. The heavier neutralinos and charginos as well as the sleptons, squarks and gluinos are too heavy to be pair produced. We calculate the signal cross section and also the standard model background from radiative neutrino production. For our scenarios, we obtain significances larger than 10 and signal to background ratios between 2% and 5%, if we have electron beam polarization P_{e^-} = 0.0 0.8 and positron beam polarization P_{e^+} = 0.0 0.3. If we have electron beam polarization of P_{e^-} = 0.9, then the signal is observable with P_{e^+} = 0.0 but both the significance and the signal to background ratio are significantly improved for P_{e^+} = 0.3.

  2. Radiation optic neuropathy after external beam radiation therapy for acromegaly : report of two cases

    NARCIS (Netherlands)

    van den Bergh, ACM; Hoving, MA; Links, TP; Dullaart, RPF; Ranchor, AV; ter Weeme, CA; Canrinus, AA; Szabo, BG; Pott, JWR

    2003-01-01

    For diagnosing radiation optic neuropathy (RON) ophthalmological and imaging data were evaluated from 63 acromegalic patients, irradiated between 1967 and 1998. Two patients developed RON: one patient in one optic nerve 10 years and another patient in both optic nerves 5 months after radiation thera

  3. Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam

    Science.gov (United States)

    Di Lillo, F.; Dreossi, D.; Emiro, F.; Fedon, C.; Longo, R.; Mettivier, G.; Rigon, L.; Russo, P.; Tromba, G.

    2015-05-01

    In the framework of an ongoing project, promoted by INFN, at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) for phase-contrast breast X-ray computed tomography, the assessment of the dose to the breast is one of the issues, requiring the determination of the distribution of X-ray incident photon fluence. This work investigates the use of XR-QA2 radiochromic films for quantitative imaging of the synchrotron radiation (SR) beam. XR-QA2 films were irradiated in a plane transverse to the beam axis, with a monochromatic beam of energy of 28, 35, 38 or 40 keV. The response of the radiochromic film was calibrated in terms of average air kerma measured with an ionization chamber. The net reflectance of the exposed film was then converted to photon fluence per unit air kerma (mm-2mGy-1). The SR beam profile was acquired also with a scintillator (GOS) based, fiber optic coupled CCD camera as well as with a scintillator based flat panel detector. Horizontal and vertical line profiles acquired with the radiochromic films show the 2D distribution of the beam intensity, with variations in the order of 15-20% in the horizontal direction. The response of the radiochromic film is comparable to that of the other imaging detectors, within less than 5% variation.

  4. Transmission of solar radiation through optical fiber and application to solar beam excited laser

    Energy Technology Data Exchange (ETDEWEB)

    Arashi, Haruo; Kaimai, Atsushi; Ishigame, Mareo

    1987-12-01

    This paper describes the transmission of high density solar radiation through optical fiber and application to a solar beam excited laser. Input solar beam, rendered a high density through a solar collector, is transmitted through optical fiber, and is separated into several fluxes. The fluxes of light are introduced into the side of a cylindrical laser mirror, where the optical fibres are made up into a rectangular form. The transmitted beam, passing through a side slit, excites a rod positioned at the centre of the laser. The separation of a solar collecting and an oscillating portion serves to increase the degree of freedom. The core of the optical fiber is composed of quartz, and a polymer cladding type having a large number of apertures. The input end of the fiber is a heat resistant air-cladding type. The fibre has a transmission of 93%, which is satisfactory for use. The optical excitation system is composed of, in combination, an elliptically cylindrical laser mirror and a cylindrical laser mirror, both of which have an internal surface gold-plated throughout. The output beam from the fiber is multiple-refracted to excite the laser efficiently. When laser beam with low intensity excited by a lamp is made to pass through a crystal of the above excitation system, the intensity is amplified. It is planned that direct laser oscillation is realized by increase of solar radiation intensity. (9 figs, 5 refs)

  5. The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Jang Hyeon; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Park, Jin Hong [Dept. of Radiation Oncology, Seoul national university Bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with TrueBeam{sup TM} STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

  6. Radiation and Background Levels in a CLIC Detector due to Beam-Beam Effects Optimisation of Detector Geometries and Technologies

    CERN Document Server

    Sailer, André; Lohse, Thomas

    2013-01-10

    The high charge density---due to small beam sizes---and the high energy of the proposed CLIC concept for a linear electron--positron collider with a centre-of-mass energy of up to 3~TeV lead to the production of a large number of particles through beam-beam interactions at the interaction point during every bunch crossing (BX). A large fraction of these particles safely leaves the detector. A still significant amount of energy will be deposited in the forward region nonetheless, which will produce secondary particles able to cause background in the detector. Furthermore, some particles will be created with large polar angles and directly cause background in the tracking detectors and calorimeters. The main sources of background in the detector, either directly or indirectly, are the incoherent $mathrm{e}^{+}mathrm{e}^{-}$ pairs and the particles from $gammagamma ightarrow$ hadron events. The background and radiation levels in the detector have to be estimated, to study if a detector is feasible, that can han...

  7. Radiation quality and ion-beam therapy: understanding the users' needs.

    Science.gov (United States)

    Magrin, G; Mayer, R; Verona, C; Grevillot, Loïc

    2015-09-01

    Ion-beam therapy faces a growing demand of tools able to map radiation quality within the irradiated volume. Although analytical computations and simulations provide useful estimations of dose and radiation quality, the direct measure of those parameters would improve ion-beam therapy in particular when deep-seated tumours are irradiated, tissue composition and density are variable or organs at risk are near the tumour. Several ion-beam therapy facilities are studying detectors and procedures for measuring the radiation quality on a microdosimetric as well as a nanodosimetric scale. Simplicity and miniaturisation of the devices are essential for measurements first in phantoms and thereafter during therapy, particularly for intra-cavity detectors. MedAustron is studying solid-state detectors based on a single crystal chemical vapour deposition diamond. In collaboration with Italian National Institute for Nuclear Physics (INFN), Tor Vergata and Legnaro; INFN-microdosimetry and track structure project; Austrian Institute of Technology, Vienna; and Italian National agency for new technologies, energy and sustainable economic development, Rome, prototypes have been developed to characterise radiation quality in sizes equivalent to one micrometre of biological tissue.

  8. Radiative corrections to chargino production in electron-positron collisions with polarized beams

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Marco A.; King, Stephen F.; Ross, Douglas A.

    2001-07-01

    We study radiative corrections to chargino production at linear colliders with polarized electron beams. We calculate the one-loop corrected cross sections for polarized electon beams due to three families of quarks and squarks, working in the {ovr MS} scheme, extending our previous calculation of the unpolarized cross section with one-loop corrections due to the third family of quarks and squarks. In some cases we find rather large corrections to the tree-level cross sections. For example, for the case of right-handed polarized electrons and large tan{beta} the corrections can be of order 30%, allowing sensitivity to the squark mass parameters.

  9. Measuring radiation damage dynamics by pulsed ion beam irradiation: 2016 project annual report

    Energy Technology Data Exchange (ETDEWEB)

    Kucheyev, Sergei O. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-01-04

    The major goal of this project is to develop and demonstrate a novel experimental approach to access the dynamic regime of radiation damage formation in nuclear materials. In particular, the project exploits a pulsed-ion-beam method in order to gain insight into defect interaction dynamics by measuring effective defect interaction time constants and defect diffusion lengths. For Year 3, this project had the following two major milestones: (i) the demonstration of the measurement of thermally activated defect-interaction processes by pulsed ion beam techniques and (ii) the demonstration of alternative characterization techniques to study defect dynamics. As we describe below, both of these milestones have been met.

  10. A novel method for sub-micrometer transverse electron beam size measurements using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Aryshev, A; Boogert, S T; Karataev, P [John Adams Institute at Royal Holloway, Egham, Surrey, TW20 0EX (United Kingdom); Howell, D [John Adams Institute at Oxford University, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH (United Kingdom); Terunuma, N; Urakawa, J, E-mail: alar@post.kek.j [KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2010-06-01

    Optical Transition Radiation (OTR) appearing when a charged particle crosses a boundary between two media with different dielectric properties has widely been used as a tool for transverse profile measurements of charged particle beams in various facilities worldwide. The resolution of the monitor is defined by so-called Point Spread Function (PSF), source distribution generated by a single electron and projected by an optical system onto a screen. In this paper we represent the development of a novel sub-micrometre electron beam profile monitor based on the measurements of the PSF structure. The first experimental results are presented and future plans on the optimization of the monitor are discussed

  11. Determination of the LEP Beam Energy using Radiative Fermion-pair Events, 2004

    CERN Document Server

    Abbiendi, G; Åkesson, P F; Alexander, G; Allison, J; Amaral, P; Anagnostou, G; Anderson, K J; Asai, S; Axen, D A; Bailey, I; Barberio, E; Barillari, T; Barlow, R J; Batley, J Richard; Bechtle, P; Behnke, T; Bell, K W; Bell, P J; Bella, G; Bellerive, A; Benelli, G; Bethke, Siegfried; Biebel, O; Boeriu, O; Bock, P; Boutemeur, M; Braibant, S; Brown, R M; Burckhart, H J; Campana, S; Capiluppi, P; Carnegie, R K; Carter, A A; Carter, J R; Chang, C Y; Charlton, D G; Ciocca, C; Csilling, A; Cuffiani, M; Dado, S; de Roeck, A; De Wolf, E A; Desch, Klaus; Dienes, B; Donkers, M; Dubbert, J; Duchovni, E; Duckeck, G; Duerdoth, I P; Etzion, E; Fabbri, Franco Luigi; Ferrari, P; Fiedler, F; Fleck, I; Ford, M; Frey, A; Gagnon, P; Gary, J W; Geich-Gimbel, C; Giacomelli, G; Giacomelli, P; Giunta, M; Goldberg, J; Gross, E; Grunhaus, Jacob; Gruwé, M; Günther, P O; Sen-Gupta, A; Hajdu, C; Hamann, M; Hanson, G G; Harel, A; Hauschild, M; Hawkes, C M; Hawkings, R; Hemingway, R J; Herten, G; Heuer, R D; Hill, J C; Hoffman, K; Horváth, D; Igo-Kemenes, P; Ishii, K; Jeremie, H; Jovanovic, P; Junk, T R; Kanzaki, J; Karlen, Dean A; Kawagoe, K; Kawamoto, T; Keeler, R K; Kellogg, R G; Kennedy, B W; Kluth, S; Kobayashi, T; Kobel, M; Komamiya, S; Kramer, T; Krieger, P; Von Krogh, J; Kühl, T; Kupper, M; Lafferty, G D; Landsman, Hagar Yaël; Lanske, D; Lellouch, D; Letts, J; Levinson, L; Lillich, J; Lloyd, S L; Loebinger, F K; Lü, J; Ludwig, A; Ludwig, J; Mader, W; Marcellini, S; Martin, A J; Masetti, G; Mashimo, T; Mättig, P; McKenna, J A; McPherson, R A; Meijers, F; Menges, W; Merritt, F S; Mes, H; Meyer, N; Michelini, A; Mihara, S; Mikenberg, G; Miller, D J; Mohr, W; Mori, T; Mutter, A; Nagai, K; Nakamura, I; Nanjo, H; Neal, H A; Nisius, R; O'Neale, S W; Oh, A; Oreglia, M J; Orito, S; Pahl, C; Pásztor, G; Pater, J R; Pilcher, J E; Pinfold, J L; Plane, D E; Pooth, O; Przybycien, M B; Quadt, A; Rabbertz, K; Rembser, C; Renkel, P; Roney, J M; Rossi, A M; Rozen, Y; Runge, K; Sachs, K; Saeki, T; Sarkisyan-Grinbaum, E; Schaile, A D; Schaile, O; Scharff-Hansen, P; Schieck, J; Schörner-Sadenius, T; Schröder, M; Schumacher, M; Seuster, R; Shears, T G; Shen, B C; Sherwood, P; Skuja, A; Smith, A M; Sobie, R J; Söldner-Rembold, S; Spanó, F; Stahl, A; Strom, D; Ströhmer, R; Tarem, S; Tasevsky, M; Teuscher, R; Thomson, M A; Torrence, E; Toya, D; Tran, P; Trigger, I; Trócsányi, Z L; Tsur, E; Turner-Watson, M F; Ueda, I; Ujvári, B; Vollmer, C F; Vannerem, P; Vertesi, R; Verzocchi, M; Voss, H; Vossebeld, Joost Herman; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Wells, P S; Wengler, T; Wermes, N; Wilson, G W; Wilson, J A; Wolf, G; Wyatt, T R; Yamashita, S; Zer-Zion, D; Zivkovic, L

    2004-01-01

    We present a determination of the LEP beam energy using "radiative return" fermion-pair events recorded at centre-of-mass energies from 183 GeV to 209 GeV. We find no evidence of a disagreement between the OPAL data and the LEP Energy Workings Group's standard calibration. Including the energy- averaged 11 MeV uncertainty in the standard determination, the beam energy we obtain from the OPAL data is higher than that obtained from the LEP calibration by 0+-34(stat.)+-27(syst.)MeV

  12. Cone-Beam Computed Tomography for Image-Guided Radiation Therapy of Prostate Cancer

    Science.gov (United States)

    2010-01-01

    extrafo al spot of an x-ray tube in one-beam omputed tomography, AAPM , Houston, TX,2008. 13 5. E. Pearson, S. Cho, X. Pan, and C. A. Pelizzari, Dose...redu tion in CBCT via intensity-weighted region-of-interest imaging, AAPM , Houston, TX, 2008.6. E. Pearson, S. Cho, X. Pan, and C. A. Pelizzari...Pelizzari, and X. Pan, Exa t image re onstru tion in reverseheli al one-beam CT for radiation therapy, AAPM , Minneapolis, MN, 2007.9. X. Han, S. Cho

  13. Radiation forces on a Rayleigh dielectric sphere produced by highly focused parabolic scaling Bessel beams.

    Science.gov (United States)

    Guo, Mengwen; Zhao, Daomu

    2017-02-20

    The radiation forces on a Rayleigh dielectric particle induced by a highly focused parabolic scaling Bessel beam (PSBB) are investigated. Numerical results show that the zero-order PSBB can be used to trap a high-index particle at the focus and near the focus by the first-order PSBB. For the low-index particle, it can be guided or confined in the dark core of the nonzero-order PSBB but cannot be stably trapped in this single-beam trap. Further, we analyze the condition of trapping stability. It is found that the lower limit in the particle radius for stable trapping is different for different orders.

  14. A Novel Approach to Beam Steering Using Arrays Composed of Multiple Unique Radiating Modes

    Science.gov (United States)

    Labadie, Nathan Richard

    Phased array antennas have found wide application in both radar and wireless communications systems particularly as implementation costs continue to decrease. The primary advantages of electronically scanned arrays are speed of beam scan and versatility of beamforming compared to mechanically scanned fixed beam antennas. These benefits come at the cost of a few well known design issues including element pattern rolloff and mutual coupling between elements. Our primary contribution to the field of research is the demonstration of significant improvement in phased array scan performance using multiple unique radiating modes. In short, orthogonal radiating modes have minimal coupling by definition and can also be generated with reduced rolloff at wide scan angles. In this dissertation, we present a combination of analysis, full-wave electromagnetic simulation and measured data to support our claims. The novel folded ring resonator (FRR) antenna is introduced as a wideband and multi-band element embedded in a grounded dielectric substrate. Multiple radiating modes of a small ground plane excited by a four element FRR array were also investigated. A novel hemispherical null steering antenna composed of two collocated radiating elements, each supporting a unique radiating mode, is presented in the context of an anti-jam GPS receiver application. Both the antenna aperture and active feed network were fabricated and measured showing excellent agreement with analytical and simulated data. The concept of using an antenna supporting multiple radiating modes for beam steering is also explored. A 16 element hybrid linear phased array was fabricated and measured demonstrating significantly improved scan range and scanned gain compared to a conventional phased array. This idea is expanded to 2 dimensional scanning arrays by analysis and simulation of a hybrid phased array composed of novel multiple mode monopole on patch antenna sub-arrays. Finally, we fabricated and

  15. Physical conditions for sources radiating a cosh-Gaussian model beam

    Institute of Scientific and Technical Information of China (English)

    LI Jia

    2011-01-01

    Based on the coherence theory of diffracted optical field and the model for partially coherent beams, analytical expressions for the cross-spectral density and the irradiance spectral density in the far zone are derived, respectively. Utilizing the theoretical model of radiation from secondary planar sources, the physical conditions for sources generating a cosh-Gaussian (CHG) beam are investigated. Analytical results demonstrate that the parametric conditions strongly depend on the coherence property of sources. When almost coherence property is satisfied in the source plane, the conditions are the same as those for fundamental Gaussian beams; when partial coherence or almost incoherence property is satisfied in the spatial source plane, the conditions are the same as those for Gaussian-Schell model beams. The results also indicate that the variance of cosine parameters has no influence on the conditions. Our results may provide potential applications for some investigations such as the modulations of cosh-Gaussian beams and the designs of source beam parameters.

  16. Control of Coherent Synchrotron Radiation and Micro-Bunching Effects During Transport of High Brightness Electron Beams

    CERN Document Server

    Douglas, D R; Hutton, A; Krafft, G A; Li, R; Neil, G R; Roblin, Y; Tennant, C D; Tsai, C -Y

    2014-01-01

    Beam quality preservation during transport of high-brightness electron beams is of general concern in the design of modern accelerators. Methods to manage incoherent synchrotron radiation (ISR) have been in place for decades; as beam brightness has improved coherent synchrotron radiation (CSR) and the microbunching instability (uBI) have emerged as performance limitations. We apply the compensation analysis of diMitri, Cornacchia, and Spampinati - as previously used by Borland - to the design of transport systems for use with low-emittance beams, and find that appropriately configured second order achromats will suppress transverse emittance growth due to CSR and appear to limit uBI gain.

  17. X-ray radiation channeling in micro-channel plates: Spectroscopy with a synchrotron radiation beam

    Energy Technology Data Exchange (ETDEWEB)

    Mazuritskiy, M.I. [Physics Department, Southern Federal University, Rostov-on-Don (Russian Federation); Dabagov, S.B. [INFN Laboratori Nazionali di Frascati, 00044 Frascati (Italy); RAS P.N. Lebedev Physical Institute, Leninsky pr. 53, 119991 Moscow (Russian Federation); National Research Nuclear University MEPhI, Kashirskoe shosse 31, 115409 Moscow (Russian Federation); Marcelli, A. [INFN Laboratori Nazionali di Frascati, 00044 Frascati (Italy); RICMASS, Rome International Center for Materials Science Superstripes, via dei Sabelli 119A, 00185 Rome (Italy); Dziedzic-Kocurek, K. [M. Smoluchowski Institute of Physics, Jagiellonian University, Krakow (Poland); Lerer, A.M. [Physics Department, Southern Federal University, Rostov-on-Don (Russian Federation)

    2015-07-15

    We present here the angular distribution of the radiation propagated inside MultiChannel Plates with micro-channels of ∼3 μm diameter. The spectra collected at the exit of the channels present a complex distribution with contributions that can be assigned to the fluorescence radiation, originated from the excitation of the micro-channel walls. For radiation above the absorption edge, when the monochromatic energy in the region of the Si L-edge hits the micro-channel walls with a grazing angle θ ⩾ 5°, or at the O K-edge when θ ⩾ 2° a fluorescence radiation is detected. Additional information associated to the fine structures of the XANES spectra detected at the exit of MCPs are also presented and discussed.

  18. Evaluation of risk from space radiation with high-energy heavy ion beams

    Science.gov (United States)

    Schimmerling, W.; Wilson, J. W.; Cucinotta, F.; Kim, M. H.

    1998-01-01

    The most challenging radiation in space consists of fully ionized atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in shield materials is poorly understood since there are few human data and a systematic study in relevant animal model systems has not been made. The accuracy of risk prediction is described as the major limiting factor in the management of space radiation risk. The expected impact of systematic studies is examined using the limited available biological data and models. Given the limitations of current predictions, models must be developed that are able to incorporate the required fundamental scientific data into accurate risk estimates. The important radiation components that can be provided for laboratory testing are identified. The use of ground-based accelerator beams to simulate space radiation is explained and quantitative scientific constraints on such facilities are derived. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjuction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required.

  19. Beam-induced radiation in the compact muon solenoid tracker at the Large Hadron Collider

    Indian Academy of Sciences (India)

    A P Singh; P C Bhat; N V Mokhov; S Beri

    2010-05-01

    The intense radiation environment at the Large Hadron Collider, CERN at a design energy of $\\sqrt{s} = 14$ TeV and a luminosity of 1034 cm−2S−1 poses unprecedented challenges for safe operation and performance quality of the silicon tracker detectors in the CMS and ATLAS experiments. The silicon trackers are crucial for the physics at the LHC experiments, and the inner layers, being situated only a few centimeters from the interaction point, are most vulnerable to beam-induced radiation. We have recently carried out extensive Monte Carlo simulation studies using MARS program to estimate particle fluxes and radiation dose in the CMS silicon pixel and strip trackers from proton–proton collisions at $\\sqrt{s} = 14$ TeV and from machine-induced background such as beam–gas interactions and beam halo. We will present results on radiation dose, particle fluxes and spectra from these studies and discuss implications for radiation damage and performance of the CMS silicon tracker detectors.

  20. External-beam radiation therapy after surgical resection and intraoperative electron-beam radiation therapy for oligorecurrent gynecological cancer. Long-term outcome

    Energy Technology Data Exchange (ETDEWEB)

    Sole, C.V. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Instituto de Radiomedicina, Service of Radiation Oncology, Santiago (Chile); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Calvo, F.A. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lozano, M.A.; Gonzalez-Sansegundo, C. [Hospital General Universitario Gregorio Maranon, Department of Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Gonzalez-Bayon, L. [Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Alvarez, A. [Hospital General Universitario Gregorio Maranon, Service of Radiation Oncology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Lizarraga, S. [Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Institute of Research Investigation, Madrid (Spain); Garcia-Sabrido, J.L. [Complutense University, School of Medicine, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Service of General Surgery, Madrid (Spain); Hospital General Universitario Gregorio Maranon, Department of Gynecology, Madrid (Spain)

    2014-02-15

    The goal of the present study was to analyze prognostic factors in patients treated with external-beam radiation therapy (EBRT), surgical resection and intraoperative electron-beam radiotherapy (IOERT) for oligorecurrent gynecological cancer (ORGC). From January 1995 to December 2012, 61 patients with ORGC [uterine cervix (52 %), endometrial (30 %), ovarian (15 %), vagina (3 %)] underwent IOERT (12.5 Gy, range 10-15 Gy), and surgical resection to the pelvic (57 %) and paraaortic (43 %) recurrence tumor bed. In addition, 29 patients (48 %) also received EBRT (range 30.6-50.4 Gy). Survival outcomes were estimated using the Kaplan-Meier method, and risk factors were identified by univariate and multivariate analyses. Median follow-up time for the entire cohort of patients was 42 months (range 2-169 months). The 10-year rates for overall survival (OS) and locoregional control (LRC) were 17 and 65 %, respectively. On multivariate analysis, no tumor fragmentation (HR 0.22; p = 0.03), time interval from primary tumor diagnosis to locoregional recurrence (LRR) < 24 months (HR 4.02; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.95; p = 0.02) retained significance with regard to LRR. Time interval from primary tumor to LRR < 24 months (HR 2.32; p = 0.02) and no EBRT at the time of pelvic recurrence (HR 3.77; p = 0.04) showed a significant association with OS after adjustment for other covariates. External-beam radiation therapy at the time of pelvic recurrence, time interval for relapse ≥24 months and not multi-involved fragmented resection specimens are associated with improved LRC in patients with ORGC. As suggested from the present analysis a significant group of ORGC patients could potentially benefit from multimodality rescue treatment. (orig.)

  1. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  2. Patient radiation dose and protection from cone-beam computed tomography

    OpenAIRE

    Li,Gang

    2013-01-01

    After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from 19 µSv to 1073 µSv and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply...

  3. E-Beam Processing of Polymer Matrix Composites for Multifunctional Radiation Shielding

    Science.gov (United States)

    Hou, Tan-Hung; Wilson, John W.; Jensen, Brian J.; Thibeault, Sheila A.; Chang, Chie K.; Kiefer, Richard L.

    2005-01-01

    Aliphatic polymers were identified as optimum radiation shielding polymeric materials for building multifunctional structural elements for in-space habitats. Conceptual damage tolerant configurations of polyolefins have been proposed, but many manufacturing issues relied on methods and materials which have sub-optimal radiation shielding characteristics (for example, epoxy matrix and adhesives). In the present approach, we shall investigate e-beam processing technologies for inclusion of high-strength aliphatic polymer reinforcement structures into a highly cross-linked polyolefin matrix. This paper reports the baseline thermo-mechanical properties of low density polyethylene and highly crystallized polyethylene.

  4. Small Radiation Beam Dosimetry for Radiosurgery of Trigeminal Neuralgia: One Case Analysis

    Science.gov (United States)

    García-Garduño, O. A.; Lárraga-Gutiérrez, J. M.; Rodríguez-Villafuerte, M.; Martínez-Dávalos, A.; Moreno-Jiménez, S.; Suárez-Campos, J. J.; Celis, M. A.

    2008-08-01

    The use of small radiation beams for trigeminal neuralgia (TN) treatment requires high precision and accuracy in dose distribution calculations and delivery. Special attention must be kept on the type of detector to be used. In this work, the use of GafChromic EBT® radiochromic and X-OMAT V2 radiographic films for small radiation beam characterization is reported. The dosimetric information provided by the films (total output factors, tissue maximum ratios and off axis ratios) is compared against measurements with a shielded solid state (diode) reference detector. The film dosimetry was used for dose distribution calculations for the treatment of trigeminal neuralgia radiosurgery. Comparison of the isodose curves shows that the dosimetry produced with the X-OMAT radiographic film overestimates the dose distributions in the penumbra region.

  5. A novel fast response and radiation-resistant scintillator detector for beam loss monitor

    Science.gov (United States)

    Ji, Y.; Tang, Z.; Li, C.; Li, X.; Shao, M.

    2017-07-01

    At high luminosity area, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant scintillator detector as the beam loss monitor for high luminosity collider, especially at low energy region such as RFQ. The detector is consisted of a 2 cm× 2 cm× 0.5 cm LYSO crystal readout by a 6 mm × 6 mm Silicon photomultiplier. Test results from various radioactive sources show that the detector has good sensitivity to photons from tens of keV to several MeV with good linearity and energy resolution (23% for 60 keV γ-ray). For field test, two such detectors are installed outside of the vacuum chamber shell of an 800 MeV electron storage ring. The details of the test and results are introduced.

  6. Recent developments of ion beam induced luminescence: radiation hardness study of thin film plastic scintillators

    Science.gov (United States)

    Quaranta, Alberto

    2005-10-01

    Ion beam induced luminescence (IBIL) measurements have been performed on thin film scintillators based on polyvinyltoluene (PVT) and 6FDA-DAD and BPDA-3F polyimides with H+ (1.85 MeV) and He+ (1.8-2.2 MeV) ion beams. The radiation hardness of the undoped polymers has been verified to depend mainly on the deposited energy density, polyimides exhibiting a higher resistance with respect to PVT. In PVT a new fluorescence band, attributed to the radical precursors of the network crosslinking, has been observed. The efficiency of doped polymers degradates with a higher rate, depending on the dye intrinsic lability. At high radiation fluences, the relative efficiency to NE102 of doped polyimides scintillators increases owing to the intrinsic host improved resistance.

  7. Electron-beam dynamics in a strong laser field including quantum radiation reaction

    CERN Document Server

    Neitz, Norman

    2014-01-01

    The evolution of an electron beam colliding head-on with a strong plane-wave field is investigated in the framework of strong-field QED including radiation-reaction effects due to photon emission. Employing a kinetic approach to describe the electron and the photon distribution it is shown that at a given total laser fluence the final electron distribution depends on the shape of the laser envelope and on the pulse duration, in contrast to the classical predictions of radiation reaction based on the Landau-Lifshitz equation. Finally, it is investigated how the pair-creation process leads to a nonlinear coupled evolution of the electrons in the beam, of the produced charged particles, and of the emitted photons.

  8. Electron-beam dynamics in a strong laser field including quantum radiation reaction

    Science.gov (United States)

    Neitz, N.; Di Piazza, A.

    2014-08-01

    The evolution of an electron beam colliding head on with a strong plane-wave field is investigated in the framework of strong-field QED including radiation-reaction effects due to photon emission. Employing a kinetic approach to describe the electron and the photon distribution it is shown that at a given total laser fluence the final electron distribution depends on the shape of the laser envelope and on the pulse duration, in contrast to the classical predictions of radiation reaction based on the Landau-Lifshitz equation. Finally, it is investigated how the pair-creation process leads to a nonlinear coupled evolution of the electrons in the beam, of the produced charged particles, and of the emitted photons.

  9. Diffraction Radiation Diagnostics for Moderate to High Energy Charged Particle Beams

    CERN Document Server

    Fiorito, R B

    2001-01-01

    Diffraction radiation (DR) is produced when a charged particle passes throughan aperture or near a discontinuity in the media in which it is traveling. DRis closely related to transition radiation (TR), which is produced when acharged particle traverses the boundary between media with different dielectricconstants. In contrast to TR, which is now extensively used for beam diagnosticpurposes, the potential of DR as a non-interceptive, multi-parameter beamdiagnostic remains largely undeveloped. For diagnostic measurements it isuseful to observe backward reflected DR from an circular aperture or slitinclined with respect to the beam velocity. However, up to now, well foundedequations for the spectral-angular intensities of backward DR from suchapertures have not been available. We present a new derivation of the spectralangular intensity of backward DR produced from an inclined slit for twoorientations of the slit axis, i.e. perpendicular and parallel to the plane ofincidence. Our mathematical approach is genera...

  10. In vivo pink-beam imaging and fast alignment procedure for rat brain tumor radiation therapy.

    Science.gov (United States)

    Nemoz, Christian; Kibleur, Astrid; Hyacinthe, Jean Noël; Berruyer, Gilles; Brochard, Thierry; Bräuer-Krisch, Elke; Le Duc, Géraldine; Brun, Emmanuel; Elleaume, Hélène; Serduc, Raphaël

    2016-01-01

    A fast positioning method for brain tumor microbeam irradiations for preclinical studies at third-generation X-ray sources is described. The three-dimensional alignment of the animals relative to the X-ray beam was based on the X-ray tomography multi-slices after iodine infusion. This method used pink-beam imaging produced by the ID17 wiggler. A graphical user interface has been developed in order to define the irradiation parameters: field width, height, number of angles and X-ray dose. This study is the first reporting an image guided method for soft tissue synchrotron radiotherapy. It allowed microbeam radiation therapy irradiation fields to be reduced by a factor of ∼20 compared with previous studies. It permitted more targeted, more efficient brain tumor microbeam treatments and reduces normal brain toxicity of the radiation treatment.

  11. Pelvic complications after definitive treatment of prostate cancer by interstitial or external beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schellhammer, P.F.; El-Mahdi, A.M.

    1983-05-01

    Radiation complications, after definitive treatment of localized prostatic carcinoma by either external beam or interstitial implantation with Iodine-125 seeds, are reviewed. Late serious complications to immediately adjacent structures of the anterior rectal wall, prostatic urethra, bladder neck, and external sphincter occurred with similar frequency in both treatment groups. However, late serious complications of the remotely adjacent structures of the bladder, urethra, distal ureters, and circumferential rectal wall occurred more frequently in the external beam treatment series, a reflection of the fact that larger tissue volumes were irradiated. Rectal ulceration, while occurring in both treatment groups, was amenable to surgical correction or underwent spontaneous healing only in the 125I group. At this point in our experience, morbidity from late radiation complications has been less among those patients having interstitial implantation for definitive treatment of localized prostatic carcinoma.

  12. SU-C-16A-06: Optimum Radiation Source for Radiation Therapy of Skin Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Safigholi, Habib [Science and Research Branch, Islamic Azad University, Fars, Persepolis (Iran, Islamic Republic of); Meigooni, A S. [Comprehensive cancer center of Nevada, Las Vegas, NV (United States); University of Nevada Las Vegas (UNLV), Las Vegas, NV (United States)

    2014-06-15

    Purpose: Recently, different applicators are designed for treatment of the skin cancer such as scalp and legs, using Ir-192 HDR Brachytherapy Sources (IR-HDRS), Miniature Electronic Brachytherapy Sources (MEBXS), and External Electron Beam Radiation Therapy (EEBRT). Although, all of these methodologies may deliver the desired radiation dose to the skin, the dose to the underlying bone may become the limiting factor for selection of the optimum treatment technique. In this project the radiation dose delivered to the underlying bone has been evaluated as a function of the radiation source and thickness of the underlying bone. Methods: MC simulations were performed using MCNP5 code. In these simulations, the mono-energetic and non-divergent photon beams of 30 keV, 50 keV, and 70 keV for MEBXS, 380 keV photons for IR-HDRS, and 6 MeV mono-energetic electron beam for EEBRT were modeled. A 0.5 cm thick soft tissue (0.3 cm skin and 0.2 cm adipose) with underlying 0.5 cm cortical bone followed by 14 cm soft tissue are utilized for simulations. Results: Dose values to bone tissue as a function of beam energy and beam type, for a delivery of 5000 cGy dose to skin, were compared. These results indicate that for delivery of 5000 cGy dose to the skin surface with 30 keV, 50 keV, 70 keV of MEBXS, IR-HDRS, and EEBRT techniques, bone will receive 31750 cGy, 27450 cGy, 18550 cGy, 4875 cGy, and 10450 cGy, respectively. Conclusion: The results of these investigations indicate that, for delivery of the same skin dose, average doses received by the underlying bone are 5.2 and 2.2 times larger with a 50 keV MEBXS and EEBRT techniques than IR-HDRS, respectively.

  13. Laser-Driven Very High Energy Electron/Photon Beam Radiation Therapy in Conjunction with a Robotic System

    Directory of Open Access Journals (Sweden)

    Kazuhisa Nakajima

    2014-12-01

    Full Text Available We present a new external-beam radiation therapy system using very-high-energy (VHE electron/photon beams generated by a centimeter-scale laser plasma accelerator built in a robotic system. Most types of external-beam radiation therapy are delivered using a machine called a medical linear accelerator driven by radio frequency (RF power amplifiers, producing electron beams with an energy range of 6–20 MeV, in conjunction with modern radiation therapy technologies for effective shaping of three-dimensional dose distributions and spatially accurate dose delivery with imaging verification. However, the limited penetration depth and low quality of the transverse penumbra at such electron beams delivered from the present RF linear accelerators prevent the implementation of advanced modalities in current cancer treatments. These drawbacks can be overcome if the electron energy is increased to above 50 MeV. To overcome the disadvantages of the present RF-based medical accelerators, harnessing recent advancement of laser-driven plasma accelerators capable of producing 1-GeV electron beams in a 1-cm gas cell, we propose a new embodiment of the external-beam radiation therapy robotic system delivering very high-energy electron/photon beams with an energy of 50–250 MeV; it is more compact, less expensive, and has a simpler operation and higher performance in comparison with the current radiation therapy system.

  14. Conditions for coherent-synchrotron-radiation-induced microbunching suppression in multibend beam transport or recirculation arcs

    Science.gov (United States)

    Tsai, C.-Y.; Di Mitri, S.; Douglas, D.; Li, R.; Tennant, C.

    2017-02-01

    The coherent synchrotron radiation (CSR) of a high-brightness electron beam traversing a series of dipoles, such as transport or recirculation arcs, may result in beam phase space degradation. On one hand, CSR can perturb electron transverse motion in dispersive regions along the beam line and possibly cause emittance growth. On the other hand, the CSR effect on the longitudinal beam dynamics could result in microbunching instability. For transport arcs, several schemes have been proposed to suppress the CSR-induced emittance growth. Correspondingly, a few scenarios have been introduced to suppress CSR-induced microbunching instability, which however mostly aim for linac-based machines. In this paper we provide sufficient conditions for suppression of CSR-induced microbunching instability along transport or recirculation arcs. Examples are presented with the relevant microbunching analyses carried out by our developed semianalytical Vlasov solver [C.-Y. Tsai, D. Douglas, R. Li, and C. Tennant, Linear microbunching analysis for recirculation machines, Phys. Rev. ST Accel. Beams 19, 114401 (2016), 10.1103/PhysRevAccelBeams.19.114401]. The example lattices include low-energy (˜100 MeV ) and high-energy (˜1 GeV ) recirculation arcs, and medium-energy compressor arcs. Our studies show that lattices satisfying the proposed conditions indeed have microbunching gain suppressed. Beam current dependences of maximal CSR microbunching gains are also demonstrated, which should help outline a beam line design for different scales of nominal currents. We expect this analysis can shed light on the lattice design approach that aims to control the CSR-induced microbunching.

  15. Conditions for coherent-synchrotron-radiation-induced microbunching suppression in multibend beam transport or recirculation arcs

    Directory of Open Access Journals (Sweden)

    C.-Y. Tsai

    2017-02-01

    Full Text Available The coherent synchrotron radiation (CSR of a high-brightness electron beam traversing a series of dipoles, such as transport or recirculation arcs, may result in beam phase space degradation. On one hand, CSR can perturb electron transverse motion in dispersive regions along the beam line and possibly cause emittance growth. On the other hand, the CSR effect on the longitudinal beam dynamics could result in microbunching instability. For transport arcs, several schemes have been proposed to suppress the CSR-induced emittance growth. Correspondingly, a few scenarios have been introduced to suppress CSR-induced microbunching instability, which however mostly aim for linac-based machines. In this paper we provide sufficient conditions for suppression of CSR-induced microbunching instability along transport or recirculation arcs. Examples are presented with the relevant microbunching analyses carried out by our developed semianalytical Vlasov solver [C.-Y. Tsai, D. Douglas, R. Li, and C. Tennant, Linear microbunching analysis for recirculation machines, Phys. Rev. ST Accel. Beams 19, 114401 (2016PRABFM1098-440210.1103/PhysRevAccelBeams.19.114401]. The example lattices include low-energy (∼100  MeV and high-energy (∼1  GeV recirculation arcs, and medium-energy compressor arcs. Our studies show that lattices satisfying the proposed conditions indeed have microbunching gain suppressed. Beam current dependences of maximal CSR microbunching gains are also demonstrated, which should help outline a beam line design for different scales of nominal currents. We expect this analysis can shed light on the lattice design approach that aims to control the CSR-induced microbunching.

  16. Instrumentation for beam radiation and luminosity measurement in the CMS experiment using novel detector technologies

    CERN Document Server

    Guthoff, Moritz

    2016-01-01

    The higher energy and luminosity of the LHC initiated the development of dedicated technologies for radiation monitoring and luminosity measurement. A pixelated luminosity detector counts coincidences in several three layer telescopes of silicon pixel detectors to measure the luminosity for each colliding LHC bunch pair. In addition, charged particle tracking allows to monitor the location of the collision point.The upgraded fast beam conditions monitor measures the particle flux using 24 two pad single crystalline diamond sensors, equipped with a fast front-end ASIC produced in 130 nm CMOS technology. The excellent time resolution is used to separate collision products from machine induced background.A new beam-halo monitor at larger radius exploits Cerenkov light produced by relativistic charged particles in fused quartz crystals to provide direction sensitivity and time resolution to separate incoming and outgoing particles. The back-end electronics of the beam monitoring systems includes dedicated modules...

  17. Very small beam-size measurement by a reflective synchrotron radiation interferometer

    Directory of Open Access Journals (Sweden)

    T. Naito

    2006-12-01

    Full Text Available A synchrotron radiation (SR interferometer with Herschelian reflective optics has been developed for the measurement of beams of several μm in size. In a conventional refractive SR interferometer, the dispersion effect of the objective lens limits the instrument to a smaller range of beam-size measurements. To avoid this problem, we designed a Herschelian arrangement of reflective optics for the interferometer. The effectiveness of the reflective SR interferometer was confirmed at the KEK Accelerator Test Facility (ATF damping ring. The measured vertical beam size obtained using the reflective SR interferometer was 4.7   μm and the estimated vertical emittance was 0.97×10^{-11}   m.

  18. Aluminum surface layer strengthening using intense pulsed beam radiation of substrate film system

    Science.gov (United States)

    Klopotov, A. A.; Ivanov, Yu F.; Vlasov, V. A.; Kondratyuk, A. A.; Teresov, A. D.; Shugurov, V. V.; Petrikova, E. A.

    2016-11-01

    The paper presents formation of the substrate film system (Zr-Ti-Cu/Al) by electric arc spraying of cathode having the appropriate composition. It is shown that the intense beam radiation of the substrate film system is accompanied by formation of the multi-phase state, the microhardness of which exceeds the one of pure A7 aluminum by ≈4.5 times.

  19. Radiation Protection Study for the Shielding Design of the LINAC4 Beam Dump at CERN

    CERN Document Server

    Blaha, Jan

    2013-01-01

    The aim of this study is to determine an optimal shielding of the LINAC4 beam dump fulfilling the radiation protection requirements. Therefore a detailed Monte-Carlo calculation using FLUKA particle transport and interaction code has been performed and the relevant physics quantities, such as particle fluences, neutron energy spectra, residual and prompt dose rates, air and water activation have been evaluated for different LINAC4 operation phases.

  20. E-beam-Cure Fabrication of Polymer Fiber/Matrix Composites for Multifunctional Radiation Shielding

    Science.gov (United States)

    Wilson, John W.; Jensen, Brian J.; Thibeault, Sheila A.; Hou, Tan-Hung; Saether, Erik; Glaessgen, Edward H.; Humes, Donald H.; Chang, Chie K.; Badavi, Francis F.; Kiefer, Rrichard L.; Adams, Dan O.

    2004-01-01

    Aliphatic polymers were identified as optimum radiation polymeric shielding materials for building multifunctional structural elements. Conceptual damage-tolerant configurations of polyolefins have been proposed but many issues on the manufacture remain. In the present paper, we will investigate fabrication technologies with e-beam curing for inclusion of high-strength aliphatic polymer fibers into a highly cross-linked polyolefin matrix. A second stage of development is the fabrication methods for applying face sheets to aliphatic polymer closed-cell foams.

  1. Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams

    CERN Document Server

    Batarin, V; Butler, J; Cheung, H; Datsko, V S; Davidenko, A; Derevshchikov, A A; Dzhelyadin, R I; Fomin, Y; Frolov, V; Goncharenko, Yu M; Grishin, V; Kachanov, V A; Khodyrev, V Yu; Khroustalev, K; Konoplyannikov, A K; Konstantinov, A S; Kravtsov, V; Kubota, Y; Leontiev, V M; Lukanin, V S; Maisheev, V; Matulenko, Yu A; Melnik, Yu M; Meshchanin, A P; Mikhalin, N; Minaev, N G; Mochalov, V; Morozov, D A; Mountain, R; Nogach, L V; Pikalov, V A; Ryazantsev, A; Semenov, P A; Shestermanov, K E; Soloviev, L; Solovyanov, V L; Stone, S; Ukhanov, M N; Uzunian, A V; Vasilev, A; Yakutin, A; Yarba, J V

    2003-01-01

    We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.

  2. Study of radiation damage in lead tungstate crystals using intense high-energy beams

    Energy Technology Data Exchange (ETDEWEB)

    Batarin, V.A.; Brennan, T.; Butler, J.; Cheung, H.; Datsko, V.S.; Davidenko, A.M.; Derevschikov, A.A.; Dzhelyadin, R.I.; Fomin, Y.V.; Frolov, V.; Goncharenko, Y.M.; Grishin, V.N.; Kachanov, V.A.; Khodyrev, V.Y.; Khroustalev, K.; Konoplyannikov, A.K.; Konstantinov, A.S.; Kravtsov, V.I.; Kubota, Y.; Leontiev, V.M.; Lukanin, V.S.; Maisheev, V.A.; Matulenko, Y.A.; Melnick, Y.M.; Meschanin, A.P.; Mikhalin, N.E.; Minaev, N.G.; Mochalov, V.V.; Morozov, D.A.; Mountain, R.; Nogach, L.V.; Pikalov, V.A.; Ryazantsev, A.V.; Semenov, P.A. E-mail: semenov@mx.ihep.su; Shestermanov, K.E.; Soloviev, L.F.; Solovianov, V.L.; Stone, S.; Ukhanov, M.N.; Uzunian, A.V.; Vasiliev, A.N.; Yakutin, A.E.; Yarba, J

    2003-10-21

    We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high-energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.

  3. Growth Defects in Langasite Crystals Observed with White Beam Synchrotron Radiation Topography

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Langasite single crystal was grown by the Czochralski method and its perfection was assessed by white beam synchrotron radiation topography. It is found that the growth core and the growth striations are the primary growth defects and they show strong X-ray kinematical contrast in the topographs. Another typical defect in LGS crystal is dislocation. The formation mechanisms of these growth defects in LGS crystals were discussed.

  4. Radiation hygienization of cattle and swine slurry with high energy electron beam

    Science.gov (United States)

    Skowron, Krzysztof; Olszewska, Halina; Paluszak, Zbigniew; Zimek, Zbigniew; Kałuska, Iwona; Skowron, Karolina Jadwiga

    2013-06-01

    The research was carried out to assess the efficiency of radiation hygienization of cattle and swine slurry of different density using the high energy electron beam based on the inactivation rate of Salmonella ssp, Escherichia coli, Enterococcus spp and Ascaris suum eggs. The experiment was conducted with use of the linear electron accelerator Elektronika 10/10 in Institute of Nuclear Chemistry and Technology in Warsaw. The inoculated slurry samples underwent hygienization with high energy electron beam of 1, 3, 5, 7 and 10 kGy. Numbers of reisolated bacteria were determined according to the MPN method, using typical microbiological media. Theoretical lethal doses, D90 doses and hygienization efficiency of high energy electron beam were determined. The theoretical lethal doses for all tested bacteria ranged from 3.63 to 8.84 kGy and for A. suum eggs from 4.07 to 5.83 kGy. Salmonella rods turned out to be the most sensitive and Enterococcus spp were the most resistant to electron beam hygienization. The effectiveness or radiation hygienization was lower in cattle than in swine slurry and in thick than in thin one. Also the species or even the serotype of bacteria determined the dose needed to inactivation of microorganisms.

  5. The Possibility of Noninvasive Micron High Energy Electron Beam Size Measurement Using Diffraction Radiation

    CERN Document Server

    Naumenko, Gennady; Aryshev, Alexander; Cline, David B; Fukui, Yasuo; Hamatsu, Ryosuke; Hayano, Hitoshi; Karataev, Pavel; Muto, Toshiya; Potylitsyn, Alexander; Ross, Marc; Urakawa, Junji

    2005-01-01

    During the last years a noninvasive method for beam size measurement based on the optical diffraction radiation (ODR) has been in progress (P. Karataev, et al., Physical Review Letters 93, 244802 (2004). However this technique encounters with hard sensitivity limitation for electron energies larger than several GeV. For example, for SLAC conditions the sensitivity of this method is 4 orders smaller than an appropriate one. We suggest to use a "dis-phased" slit target, where two semi-planes are turned with respect to each other at a small "dis-phased" angle. In order to ensure the interference between the diverged radiation beams we use a cylindrical lens. This method has much better sensitivity and resolution. A "dis-phased" angle 10 milliradians gives the optimal sensitivity to 5 microns transversal beam size. The theoretical model for calculating the ODR radiation from such targets (including focusing by cylindrical lens) is presented. It is shown that the sensitivity of this method does not depend on the L...

  6. Radiation defect dynamics in Si at room temperature studied by pulsed ion beams

    Science.gov (United States)

    Wallace, J. B.; Charnvanichborikarn, S.; Bayu Aji, L. B.; Myers, M. T.; Shao, L.; Kucheyev, S. O.

    2015-10-01

    The evolution of radiation defects after the thermalization of collision cascades often plays the dominant role in the formation of stable radiation disorder in crystalline solids of interest to electronics and nuclear materials applications. Here, we explore a pulsed-ion-beam method to study defect interaction dynamics in Si crystals bombarded at room temperature with 500 keV Ne, Ar, Kr, and Xe ions. The effective time constant of defect interaction is measured directly by studying the dependence of lattice disorder, monitored by ion channeling, on the passive part of the beam duty cycle. The effective defect diffusion length is revealed by the dependence of damage on the active part of the beam duty cycle. Results show that the defect relaxation behavior obeys a second order kinetic process for all the cases studied, with a time constant in the range of ˜4-13 ms and a diffusion length of ˜15-50 nm. Both radiation dynamics parameters (the time constant and diffusion length) are essentially independent of the maximum instantaneous dose rate, total ion dose, and dopant concentration within the ranges studied. However, both the time constant and diffusion length increase with increasing ion mass. This demonstrates that the density of collision cascades influences not only defect production and annealing efficiencies but also the defect interaction dynamics.

  7. Argon beam coagulation for treatment of symptomatic radiation-induced proctitis.

    Science.gov (United States)

    Fantin, A C; Binek, J; Suter, W R; Meyenberger, C

    1999-04-01

    Radiation proctitis is a complication of radiotherapy for malignant pelvic disease. Argon beam coagulation is a new and rapidly evolving technology that permits a "no-touch" electrocoagulation of diseased tissue. We analyzed retrospectively the records of 7 patients with prostatic and endometrial cancers treated with irrradiation (median radiation dose was 6840 cGy, range 2400 to 7200 cGy). The median time to onset of symptoms after the conclusion of radiotherapy was 20 months (range 16 to 48 months); symptoms consisted of rectal bleeding and tenesmus in all patients. The patients underwent argon beam coagulation after colonoscopic evaluation. The usual treatment interval was 3 weeks (range 1 to 3 weeks). A median of 2 treatment sessions (range 2 to 4) was necessary for complete symptom relief. All interventions were well tolerated without complications. During follow-up (median 24 months, range 18 to 24 months), there was no recurrence of symptoms (bleeding, tenesmus). Argon beam coagulation is a safe, well tolerated, and effective treatment option in symptomatic radiation proctitis.

  8. Treatment of Head and Neck Paragangliomas With External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, Charles, E-mail: c.dupin@bordeaux.unicancer.fr [Department of Radiotherapy, Comprehensive Cancer Center, Institut Bergonié, Bordeaux (France); Lang, Philippe [Department of Radiotherapy, Pitié Salpétrière, Paris (France); Dessard-Diana, Bernadette [Department of Radiotherapy, Hopital Européen Georges Pompidou, Paris (France); Simon, Jean-Marc; Cuenca, Xavier; Mazeron, Jean-Jacques; Feuvret, Loïc [Department of Radiotherapy, Pitié Salpétrière, Paris (France)

    2014-06-01

    Purpose: To retrospectively assess the outcomes of radiation therapy in patients with head and neck paragangliomas. Methods and Materials: From 1990 to 2009, 66 patients with 81 head and neck paragangliomas were treated by conventional external beam radiation therapy in 25 fractions at a median dose of 45 Gy (range, 41.4-68 Gy). One case was malignant. The median gross target volume and planning target volume were 30 cm{sup 3} (range, 0.9-243 cm{sup 3}) and 116 cm{sup 3} (range, 24-731 cm{sup 3}), respectively. Median age was 57.4 years (range, 15-84 years). Eleven patients had multicentric lesions, and 8 had family histories of paraganglioma. Paragangliomas were located in the temporal bone, the carotid body, and the glomus vagal in 51, 18, and 10 patients, respectively. Forty-six patients had exclusive radiation therapy, and 20 had salvage radiation therapy. The median follow-up was 4.1 years (range, 0.1-21.2 years). Results: One patient had a recurrence of temporal bone paraganglioma 8 years after treatment. The actuarial local control rates were 100% at 5 years and 98.7% at 10 years. Patients with multifocal tumors and family histories were significantly younger (42 years vs 58 years [P=.002] and 37 years vs 58 years [P=.0003], respectively). The association between family predisposition and multifocality was significant (P<.001). Two patients had cause-specific death within the 6 months after irradiation. During radiation therapy, 9 patients required hospitalization for weight loss, nausea, mucositis, or ophthalmic zoster. Two late vascular complications occurred (middle cerebral artery and carotid stenosis), and 2 late radiation-related meningiomas appeared 15 and 18 years after treatment. Conclusion: Conventional external beam radiation therapy is an effective and safe treatment option that achieves excellent local control; it should be considered as a first-line treatment of choice for head and neck paragangliomas.

  9. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Eftekhari

    2015-01-01

    Full Text Available Objective(s: Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. Results: A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed and 36 patients with right-sided cancer (controls] were enrolled. Dose-volume histogram (DVH [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46. In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03 and anterolateral (17.1% versus 2.8%, P=0.049 walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS of>3 was observed in twelve cases (34.3%, while in five of the controls (13.9%,(Odds ratio=1.3. There was no significant difference between the groups regarding left ventricular ejection fraction. Conclusion: The risk of radiation induced myocardial

  10. Recoil separators for radiative capture using radioactive ion beams. Recent advances and detection techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, Chris [TRIUMF, Vancouver, BC (Canada); Greife, Uwe; Hager, Ulrike [Colorado School of Mines, Golden, CO (United States)

    2014-06-15

    Radiative capture reactions involving the fusion of hydrogen or helium are ubiquitous in the stellar history of the universe, and are some of the most important reactions in the processes that govern nucleosynthesis and energy generation in both static and explosive scenarios. However, radiative capture reactions pose some of the most difficult experimental challenges due to extremely small cross sections. With the advent of recoil separators and techniques in inverse kinematics, it is now possible to measure radiative capture reactions on very short-lived radioactive nuclei, and in the presence of high experimental backgrounds. In this paper we review the experimental needs for making measurements of astrophysical importance on radiative capture reactions. We also review some of the important historical advances in the field of recoil separators as well as describe current techniques and performance milestones, including descriptions of some of the separators most recently working at radioactive ion beam facilities, such as DRAGON at TRIUMF and the DRS at the Holifield Radioactive Ion Beam Facility. We will also summarize some of the scientific highlight measurements at the RIB facilities. (orig.)

  11. Study on the radiation problem caused by electron beam loss in accelerator tubes

    Institute of Scientific and Technical Information of China (English)

    LI Quan-Feng; GUO Bing-Qi; ZHANG Jie-Xi; CHEN Huai-Bi

    2008-01-01

    The beam dynamic code PARMELA was used to simulate the transportation process of accelerating electrons in S-band SW linacs with different energies of 2.5, 6 and 20 MeV. The results indicated that in the ideal condition, the percentage of electron beam loss was 50% in accelerator tubes. Also we calculated the spectrum, the location and angular distribution of the lost electrons. Calculation performed by Monte Carlo code MCNP demonstrated that the radiation distribution of lost electrons was nearly uniform along the tube axis, the angular distributions of the radiation dose rates of the three tubes were similar, and the highest leaking dose was at the angle of 160° with respect to the axis. The lower the energy of the accelerator, the higher the radiation relative leakage. For the 2.5 MeV accelerator, the maximum dose rate reached 5% of the main dose and the one on the head of the electron gun was 1%, both of which did not meet the eligible protection requirement for accelerators. We adopted different shielding designs for different accelerators. The simulated result showed that the shielded radiation leaking dose rates fulfilled the requirement.

  12. A white-beam fast-shutter for microbeam radiation therapy at the ESRF

    CERN Document Server

    Renier, M; Nemoz, C; Thomlinson, W

    2002-01-01

    The ID17 Medical Beamline port at the European Synchrotron Radiation Facility (ESRF) delivers white beam generated by a 1.4 T wiggler. It is devoted to medical applications of synchrotron radiation. One major program of the beamline is called Microbeam Radiation Therapy (MRT). In this radiotherapy technique, still under development, the white beam fan is divided into several microbeams before reaching the target which is a tumoral brain. The maximum skin-entrance absorbed dose can reach extremely high values (over 1000 Gy) before causing tissue necrosis, while causing tumor necrosis. One of the key parameters for the success of the MRT is the accurate control of the radiation dose delivered to the target, as well as its location with respect to the tumor, to prevent unnecessary damage to normal tissues. Therefore, the opening and closing positions of the shutter while the target is moving vertically at a constant speed reaching 150 mm/s must be carefully controlled. Shutter opening times as short as 5+-0.5 ms...

  13. Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results

    Science.gov (United States)

    Garg, Akash Deep; Karnewar, A. K.; Ojha, A.; Shrivastava, B. B.; Holikatti, A. C.; Puntambekar, T. A.; Navathe, C. P.

    2014-08-01

    Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8-18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 μm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.

  14. On the suitability of longitudinal profile measurements using Coherent Smith-Purcell radiation for high current proton beams

    CERN Document Server

    Barros, Joanna; Vieille-Grosjean, Mélissa; Kittelmann, Irena Dolenc; Thomas, Cyrille

    2014-01-01

    The use of Smith-Purcell radiation to measure electrons longitudinal profiles has been demonstrated at several facilities in the picosecond and sub-picosecond range. There is a strong interest for the development of non intercepting longitudinal profile diagnostics for high current proton beams. We present here results of simulations on the expected yield of longitudinal profile monitors using Smith-Purcell radiation for such proton beams.

  15. Electron beam excitation of coherent sub-terahertz radiation in periodic structures manufactured by 3D printing

    Science.gov (United States)

    Phipps, A. R.; MacLachlan, A. J.; Robertson, C. W.; Zhang, L.; Konoplev, I. V.; Cross, A. W.; Phelps, A. D. R.

    2017-07-01

    For the creation of novel coherent sub-THz sources excited by electron beams there is a requirement to manufacture intricate periodic structures to produce and radiate electromagnetic fields. The specification and the measured performance is reported of a periodic structure constructed by additive manufacturing and used successfully in an electron beam driven sub-THz radiation source. Additive manufacturing, or ;3D printing;, is promising to be quick and cost-effective for prototyping these periodic structures.

  16. Disinfestation of agricultural products with electron beams and their radiation tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Toru [National Food Research Inst., Tsukuba, Ibaraki (Japan)

    1996-12-31

    Some agricultural products contaminated with insect pests are fumigated with methyl bromide for quarantine purposes. However, the use of methyl bromide is preferably restricted because of its ozone depleting effect. Therefore, establishing alternative quarantine techniques is highly desirable; one such technique is exposure to ionizing radiation. Few data are available on the effects of radiation on insect pests other than fruit flies and stored-product insects and on the radiation tolerance of host commodities. Radiation technology as an alternative to methyl bromide fumigation will be used to inactivate not only insects but also mites, spider mites, thrips, nematodes, scales, mealybugs and thrips contaminating fruits, grains, cut flowers, vegetables, timbers, seedlings and seeds. In order to collect data on the effects of irradiation on pests and host commodities, IAEA and FAO have conducted an international project, `FAO/IAEA Coordinated Research Programme on Irradiation as a Quarantine Treatment of Mites, Nematodes and Insects other than Fruit Fly` since 1992. The project determines the minimum doses necessary to inactivate pests and the maximum doses host commodities tolerate. All pests except nematodes can be inactivated at doses 400Gy or lower. Various varieties of cut flowers and herbs are tolerant to 400Gy of radiation, although some flowers and herbs such as chrysanthemum, rose, lily, calla, anthurium, sweet pea, iris, dill, basil and arugula are intolerant to 200Gy of radiation. Japanese research project on treatment of cut flowers with electron beams carried out mainly by Yokohama Plant Protection Station greatly contributes to these conclusions. Aqueous solution (2%) of sucrose, glucose, fructose or maltose prevents radiation-induced detrimental effects of radiation on chrysanthemums. Sugars reduce radiation-induced physiological deterioration of chrysanthemums. (author)

  17. Signatures of quantum radiation reaction in laser-electron-beam collisions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H. Y. [Helmholtz Institute Jena, Fröbelstieg 3, 07743 Jena (Germany); Yan, X. Q. [State Key Laboratory of Nuclear Physics and Technology, and Key Lab of High Energy Density Physics Simulation, CAPT, Peking University, Beijing 100871 (China); Zepf, M., E-mail: m.zepf@uni-jena.de [Helmholtz Institute Jena, Fröbelstieg 3, 07743 Jena (Germany); School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom)

    2015-09-15

    Electron dynamics in the collision of an electron beam with a high-intensity focused ultrashort laser pulse are investigated using three-dimensional QED particle-in-cell (PIC) simulations, and the results are compared with those calculated by classical Landau and Lifshitz PIC simulations. Significant differences are observed from the angular dependence of the electron energy distribution patterns for the two different approaches, because photon emission is no longer well approximated by a continuous process in the quantum radiation-dominated regime. The stochastic nature of photon emission results in strong signatures of quantum radiation-reaction effects under certain conditions. We show that the laser spot size and duration greatly influence these signatures due to the competition of QED effects and the ponderomotive force, which is well described in the classical approximation. The clearest signatures of quantum radiation reaction are found in the limit of large laser spots and few cycle pulse durations.

  18. Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors

    Science.gov (United States)

    Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, T.; Basith, A. K.; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Casarosa, G.; Ceccanti, M.; Červenkov, D.; Chendvankar, S. R.; Dash, N.; Divekar, S. T.; Doležal, Z.; Dutta, D.; Forti, F.; Friedl, M.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kang, K. H.; Kato, E.; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M.; Kvasnička, P.; Lanceri, L.; Lettenbicher, J.; Mammini, P.; Mayekar, S. N.; Mohanty, G. B.; Mohanty, S.; Morii, T.; Nakamura, K. R.; Natkaniec, Z.; Negishi, K.; Nisar, N. K.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rao, K. K.; Rizzo, G.; Rozanska, M.; Sandilya, S.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Tanaka, S.; Tanida, K.; Taylor, G. N.; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Vitale, Lorenzo; Volpi, M.; Watanuki, S.; Watson, I. J.; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.

    2016-07-01

    The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of 8 ×1035cm-2s-1 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors.

  19. Acoustic radiation force on a double-layer microsphere by a Gaussian focused beam

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Rongrong; Cheng, Kaixuan; Liu, Jiehui; Mao, Yiwei; Gong, Xiufen [Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University, Nanjing 210093 (China); Liu, Xiaozhou, E-mail: xzliu@nju.edu.cn [Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University, Nanjing 210093 (China); State Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-10-14

    A new model for calculating the radiation force on double-layer microsphere is proposed based on the ray acoustics approach. The axial acoustic radiation force resulting from a focused Gaussian beam incident on spherical shells immersed in water is examined theoretically in relation to its thickness and the contents of its double-layer. The attenuation both in the water and inside the sphere is considered in this method, which cannot be ignored while the high frequency ultrasonic is used. Results of numerical calculations are presented for fat and low density polyethylene materials, with the hollow region filled with animal oil, water, or air. These results show how the acoustic impedance and the sound velocity of both layers, together with the thickness of the shell, affect the acoustic radiation force.

  20. Radiation reaction induced spiral attractors in ultra-intense colliding laser beams

    CERN Document Server

    Gong, Z; Shou, Y R; Qiao, B; Chen, C E; Xu, F R; He, X T; Yan, X Q

    2016-01-01

    The radiation reaction effects on electron dynamics in counter-propagating circularly polarized laser beams are investigated through the linearization theorem and the results are in great agreement with numeric solutions. For the first time, the properties of fixed points in electron phase-space were analyzed with linear stability theory, showing that center nodes will become attractors if the classical radiation reaction is considered. Electron dynamics are significantly affected by the properties of the fixed points and the electron phase-space densities are found to be increasing exponentially near the attractors. The density growth rates are derived theoretically and further verified by particle-in-cell simulations, which can be detected in experiments to explore the effects of radiation reaction qualitatively. The attractor can also facilitate to realize a series of nanometer-scaled flying electron slices via adjusting the colliding laser frequencies.

  1. Application of THz probe radiation in low-coherent tomographs based on spatially separated counterpropagating beams

    Energy Technology Data Exchange (ETDEWEB)

    Kuritsyn, I I; Shkurinov, A P; Nazarov, M M [Department of Physics, M.V. Lomonosov Moscow State University (Russian Federation); Mandrosov, V I [Moscow Institute of Physics and Technology (State University), Dolgoprudnyi, Moscow Region (Russian Federation); Cherkasova, O P [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2013-10-31

    A principle of designing a high-resolution low-coherent THz tomograph, which makes it possible to investigate media with a high spatial resolution (in the range λ{sub 0} – 2λ{sub 0}, where λ{sub 0} is the average probe wavelength) is considered. The operation principle of this tomograph implies probing a medium by radiation with a coherence length of 8λ{sub 0} and recording a hologram of a focused image of a fixed layer of this medium using spatially separated counterpropagating object and reference beams. Tomograms of the medium studied are calculated using a temporal approach based on application of the time correlation function of probe radiation. (terahertz radiation)

  2. The coherent Cerenkov radiated power from a group of field-aligned test particles in a magnetoplasma

    Science.gov (United States)

    Farrell, W. M.; Goertz, C. K.

    1990-01-01

    An expression is derived that describes the coherent Cerenkov radiated power from a group of test particles in a plasma medium moving parallel to a magnetic field. In this analysis, each particle has an arbitrary position and velocity along a field line and, as a consequence, both the spatial and temporal coherence of the radiation are considered. As an example, it is demonstrated that a monoenergetic electron beam consisting of small pulses can generate wave powers well above incoherent levels if the pulse spacing is comparable to an integer number of emission wavelengths. It is also shown that, if the beam particles have a velocity spread, Delta-V, the wave powers will decrease in time due to the reduced temporal coherence of the particle radiators, where this coherence scales as 1/Delta-V. This latter effect applies to any charged particle beam propagating in a magnetoplasma, because even an initially monoenergetic beam becomes thermalized by electrostatic wave-particle interactions reducing the radiated power.

  3. Imaging Changes in Pediatric Intracranial Ependymoma Patients Treated With Proton Beam Radiation Therapy Compared to Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gunther, Jillian R. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Sato, Mariko; Chintagumpala, Murali [Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Ketonen, Leena [Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jones, Jeremy Y. [Department of Pediatric Radiology, Texas Children' s Hospital, Houston, Texas (United States); Allen, Pamela K. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Paulino, Arnold C. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Okcu, M. Fatih; Su, Jack M. [Department of Pediatrics, Section of Hematology-Oncology, Baylor College of Medicine, Texas Children' s Cancer Center, Houston, Texas (United States); Weinberg, Jeffrey [Department of Neurosurgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Boehling, Nicholas S. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Khatua, Soumen [Department of Pediatrics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Adesina, Adekunle [Department of Pathology, Baylor College of Medicine, Texas Children' s Hospital, Houston, Texas (United States); Dauser, Robert; Whitehead, William E. [Department of Neurosurgery, Texas Children' s Hospital, Houston, Texas (United States); Mahajan, Anita, E-mail: amahajan@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-09-01

    Purpose: The clinical significance of magnetic resonance imaging (MRI) changes after radiation therapy (RT) in children with ependymoma is not well defined. We compared imaging changes following proton beam radiation therapy (PBRT) to those after photon-based intensity modulated RT (IMRT). Methods and Materials: Seventy-two patients with nonmetastatic intracranial ependymoma who received postoperative RT (37 PBRT, 35 IMRT) were analyzed retrospectively. MRI images were reviewed by 2 neuroradiologists. Results: Sixteen PBRT patients (43%) developed postradiation MRI changes at 3.8 months (median) with resolution by 6.1 months. Six IMRT patients (17%) developed changes at 5.3 months (median) with 8.3 months to resolution. Mean age at radiation was 4.4 and 6.9 years for PBRT and IMRT, respectively (P=.06). Age at diagnosis (>3 years) and time of radiation (≥3 years) was associated with fewer imaging changes on univariate analysis (odds ratio [OR]: 0.35, P=.048; OR: 0.36, P=.05). PBRT (compared to IMRT) was associated with more frequent imaging changes, both on univariate (OR: 3.68, P=.019) and multivariate (OR: 3.89, P=.024) analyses. Seven (3 IMRT, 4 PBRT) of 22 patients with changes had symptoms requiring intervention. Most patients were treated with steroids; some PBRT patients also received bevacizumab and hyperbaric oxygen therapy. None of the IMRT patients had lasting deficits, but 2 patients died from recurrent disease. Three PBRT patients had persistent neurological deficits, and 1 child died secondarily to complications from radiation necrosis. Conclusions: Postradiation MRI changes are more common with PBRT and in patients less than 3 years of age at diagnosis and treatment. It is difficult to predict causes for development of imaging changes that progress to clinical significance. These changes are usually self-limiting, but some require medical intervention, especially those involving the brainstem.

  4. Do angles of obliquity apply to 30 degrees scattered radiation from megavoltage beams?

    Science.gov (United States)

    Biggs, Peter J; Styczynski, John R

    2008-10-01

    The angle of obliquity is used in radiation shielding calculations to account for the longer path length x rays will see when obliquely incident on the protective barrier. According to the National Council on Radiation Protection and Measurements (NCRP), use of the angle of obliquity is explicitly assumed for primary radiation, so that an angle of obliquity for secondary radiation is never addressed. However, in the example section of the latest report, it specifically recommends against using an angle of obliquity for scattered radiation. To check this assumption, the existence or not of an angle of obliquity for scattered radiation has been investigated for bremsstrahlung x-ray beams of 4, 6, 10, 15, and 18 MV and for barriers consisting of concrete, lead, and steel using a Monte Carlo approach. The MCNP Monte Carlo code, v4.2C, has been used to generate scattered radiation at 30 degrees from a water phantom and incident on a secondary barrier at the same angle relative to the normal to the barrier. The barrier thickness was increased from zero to a thickness sufficient to reduce the fluence (f4 tally) to concrete (5 energies) show an average angle of obliquity of 21.7 degrees +/- 5.6 degrees , and for the first two TVLs averaged 29.7 degrees +/- 3.9 degrees . The results for the first TVL in lead (3 energies) show an average angle of obliquity of 27.7 degrees +/- 4.0 degrees , and for the first two TVLs averaged 20.5 degrees +/- 5.8 degrees . There are no data in the NCRP reports for 30 degrees scattered radiation attenuated by steel with which to make a comparison.

  5. Performance of a Roos ionization chamber in gamma radiation beams ({sup 60}Co)

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana P.; Neves, Lucio P.; Caldas, Linda V.E., E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Among the different types of dosimetry instruments, the ionization chambers are the most practical and and important radiation measurement devices due to their high sensitivity and relatively constant response within a wide range of energies. A commercial PTW ionization chamber (Roos electron chamber) usually utilized in X-ray beams, was tested to verify the possibility of its dosimetric application in {sup 60}Co beams. The main tests in this work were: short- and long-term stability, saturation, ion collection efficiency, polarity effect, leakage current and angular dependence. The characterization tests were performed using a Gammatron {sup 60}Co irradiator and a special goniometer made of PMMA. All results were within international recommendations. The reproducibility test presented results within the recommended limit of {+-}1%, and all coefficients of variation observed in the repeatability test were lower than {+-}0.07%. The ion collection efficiency was better than 99.9% for both polarities. For all pairs of polarity evaluated during the saturation test, the polarity effect was lower than the recommended limit. The maximum variation obtained for angular dependence test was only 0.5%. The chamber tested in this work achieved the expected results in the case of all pre-operational tests realized: stability, leakage current, angular dependence, saturation, ion collection and polarity effect. Evaluating the satisfactory results obtained, it is possible to indicate the usefulness of this ionization chamber for dosimetry in {sup 60}Co gamma radiation beams. (author)

  6. Investigation of the possibility of using photoneutron beams for radiation therapy.

    Science.gov (United States)

    Brahme, A; Montelius, A; Nordell, B; Reuthal, M; Svensson, H

    1980-11-01

    The possibility has been investigated of using electrons accelerated by a 50 MeV racetrack microtron for generation of photoneutron beams for radiation therapy. Central axis depth-dose curves have been measured in an A-150 tissue-equivalent phantom. Neutron half-value depths between 4.4 and 5.2 g cm-2 were obtained at an SSD of 100 cm for different converter materials and target geometries. At an absorbed dose ratio of 1:1 for neutrons and photons at the dose maximum, the total absorbed dose rates are estimated to be 0.1 Gy min-1 at 100 micronA electron current and a SSD of 100 cm. At a depth of 5 cm the neutron to photon absorbed dose ratio is typically 1:2 and the OER is expected to be about 1.8. Some dose distributional and radiobiological advantages of a physically mixed beam of neutrons and photons for external beam radiation therapy are discussed.

  7. Radiation exposure from diagnostic radiography: an assessment of X-ray beam collimation practice in some Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Mr. Mark C. Okeji MSc

    2010-07-01

    Full Text Available This study was carried out to evaluate the X-ray beam collimation practice, among radiographers, as a measure of radiation protection for patients undergoing radiodiagnostic investigations. Inadequate X-ray beam collimation practice was observed in all the hospitals studied. Light beam misalignment/malfunction, pressure of work and years of experience were identified as major contributory factors. There is therefore need for proper equipment maintenance, employment of adequate number of radiographers and periodic audit of work pattern and output to minimize radiation exposure to the population.

  8. SU-E-J-17: A Study of Accelerator-Induced Cerenkov Radiation as a Beam Diagnostic and Dosimetry Tool

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, F; Tosh, R [NIST, Gaithersburg, MD (United States)

    2014-06-01

    Purpose: To investigate accelerator-induced Cerenkov radiation imaging as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams in a water phantom was imaged using a camera system comprised of a high-sensitivity thermoelectrically-cooled CCD camera coupled to a large aperture (f/0.75) objective lens with 16:1 magnification. This large format lens allows a significant amount of the available Cerenkov light to be collected and focused onto the CCD camera to form the image. Preliminary images, obtained with 6 MV photon beams, used an unshielded camera mounted horizontally with the beam normal to the water surface, and confirmed the detection of Cerenkov radiation. Several improvements were subsequently made including the addition of radiation shielding around the camera, and altering of the beam and camera angles to give a more favorable geometry for Cerenkov light collection. A detailed study was then undertaken over a range of electron and photon beam energies and dose rates to investigate the possibility of using this technique for beam diagnostics and dosimetry. Results: A series of images were obtained at a fixed dose rate over a range of electron energies from 6 to 20 MeV. The location of maximum intensity was found to vary linearly with the energy of the beam. A linear relationship was also found between the light observed from a fixed point on the central axis and the dose rate for both photon and electron beams. Conclusion: We have found that the analysis of images of beam-induced Cerenkov light in a water phantom has potential for use as a beam diagnostic and medical dosimetry tool. Our future goals include the calibration of the light output in terms of radiation dose and development of a tomographic system for 3D Cerenkov imaging in water phantoms and other media.

  9. Optical Fibre Beam Delivery of High Average Power NEODYMIUM:YAG Laser Radiation

    Science.gov (United States)

    Boechat, Alvaro A. P.

    Available from UMI in association with The British Library. This thesis presents a study of the waveguiding properties of large core (200-1000mum core diameter), relatively short length (5-50m) multimode optical fibres used for delivery of Nd:YAG laser radiation at a wavelength of 1.06mum. A major objective of the study was to provide design information for beam delivery systems used in high power materials processing application. Experimental and theoretical investigation of the optical losses produced by bending the fibre lead to a model which can be used to predict the magnitude of the bend loss as a function of launching conditions, bend geometry and fibre parameters. The study confirms the importance of using large numerical aperture, small core diameter fibres to minimise losses. It has been shown that the beam output near field profile from a fibre is a function of the launching conditions. Theoretical and experimental study of the effect for both step and graded index fibres is presented. Geometric optics and phase space theory was used to develop a model in which a relationship between input and output beam quality from a graded index fibre was established. The results showed that there is an optimum launching condition for which the beam quality may be preserved for fibres with quadratic index profiles. The effect of curvature induced mode coupling on beam quality has been studied experimentally, and compared with intrinsic mode coupling effects. The study was supported by the development of a simple theoretical mode coupling model. Finally, a new monitoring technique for beam delivery systems was developed, based on detection of power in the fibre cladding. Applications include determining laser -fibre coupling efficiency, fibre integrity monitoring, and providing real time process information.

  10. Radiation Resistance testing of commercial components for the new SPS Beam Position Measurement System

    CERN Document Server

    Deplano, C; Bogey, T; Gonzalez, J L; Savioz, J J

    2013-01-01

    A new Front-End (FE) electronics is under development for the SPS Multi Orbit POsition System (MOPOS). To cover the large dynamic range of beam intensities (70 dB) to be measured in the SPS, the beam position monitor signals are processed using logarithmic amplifiers. They are then digitized locally and transmitted via optical fibers over long distances (up to 1 km) to VME acquisition boards located in surface buildings. The FE board is designed to be located in the SPS tunnel, where it must withstand radiation doses of up to 100 Gy per year. Analogue components, such as Logarithmic Amplifiers (LA), ADC-Drivers (ADC-D) and Voltage Regulators (VR), have been tested at PSI (Paul Scherrer Institute) for radiation hardness, while several families of bidirectional SFP, both single-fiber and double-fiber, have been tested at both PSI and CNRAD. This paper gives a description of the overall system architecture and presents the results of the radiation hardness tests in detail.

  11. Instrumentation for beam radiation and luminosity measurement in the CMS experiment using novel detector technologies

    Science.gov (United States)

    Guthoff, Moritz

    2017-02-01

    The higher energy and luminosity of the LHC initiated the development of dedicated technologies for radiation monitoring and luminosity measurement. A dedicated pixelated luminosity detector measures coincidences in several three-layer telescopes of silicon pixel detectors to arrive at a luminosity for each colliding LHC bunch pair. In addition, charged particle tracking allows to monitor the location of the collision point. The upgraded fast beam conditions monitor measures the particle flux using 24 two-pad single crystalline diamond sensors, equipped with a fast front-end ASIC produced in 130 nm CMOS technology. The excellent time resolution is used to separate collision products from machine induced background. A new beam-halo monitor at larger radius exploits Cherenkov light produced by relativistic charged particles in fuzed quartz crystals to provide direction sensitivity and time resolution to separate incoming and outgoing particles. The back-end electronics of the beam monitoring systems includes dedicated modules with high bandwidth digitizers developed in both VME and microTCA standards for per bunch beam measurements and gain monitoring. All new and upgraded sub-detectors have been taking data from the first day of LHC operation in April 2015. Results on their commissioning and essential characteristics using data since the start-up of LHC will be presented.

  12. A nested partitions framework for beam angle optimization in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    D' Souza, Warren D; Nazareth, Daryl P [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); Zhang, Hao H; Shi Leyuan [Department of Industrial and Systems Engineering, University of Wisconsin, Madison, WI (United States); Meyer, Robert R [Computer Sciences Department, University of Wisconsin, Madison, WI (United States)], E-mail: dsouzaw@ohsu.edu

    2008-06-21

    Coupling beam angle optimization with dose optimization in intensity-modulated radiation therapy (IMRT) increases the size and complexity of an already large-scale combinatorial optimization problem. We have developed a novel algorithm, nested partitions (NP), that is capable of finding suitable beam angle sets by guiding the dose optimization process. NP is a metaheuristic that is flexible enough to guide the search of a heuristic or deterministic dose optimization algorithm. The NP method adaptively samples from the entire feasible region, or search space, and coordinates the sampling effort with a systematic partitioning of the feasible region at successive iterations, concentrating the search in promising subsets. We used a 'warm-start' approach by initiating NP with beam angle samples derived from an integer programming (IP) model. In this study, we describe our implementation of the NP framework with a commercial optimization algorithm. We compared the NP framework with equi-spaced beam angle selection, the IP method, greedy heuristic and random sampling heuristic methods. The results of the NP approach were evaluated using two clinical cases (head and neck and whole pelvis) involving the primary tumor and nodal volumes. Our results show that NP produces better quality solutions than the alternative considered methods.

  13. A nested partitions framework for beam angle optimization in intensity-modulated radiation therapy

    Science.gov (United States)

    D'Souza, Warren D.; Zhang, Hao H.; Nazareth, Daryl P.; Shi, Leyuan; Meyer, Robert R.

    2008-06-01

    Coupling beam angle optimization with dose optimization in intensity-modulated radiation therapy (IMRT) increases the size and complexity of an already large-scale combinatorial optimization problem. We have developed a novel algorithm, nested partitions (NP), that is capable of finding suitable beam angle sets by guiding the dose optimization process. NP is a metaheuristic that is flexible enough to guide the search of a heuristic or deterministic dose optimization algorithm. The NP method adaptively samples from the entire feasible region, or search space, and coordinates the sampling effort with a systematic partitioning of the feasible region at successive iterations, concentrating the search in promising subsets. We used a 'warm-start' approach by initiating NP with beam angle samples derived from an integer programming (IP) model. In this study, we describe our implementation of the NP framework with a commercial optimization algorithm. We compared the NP framework with equi-spaced beam angle selection, the IP method, greedy heuristic and random sampling heuristic methods. The results of the NP approach were evaluated using two clinical cases (head and neck and whole pelvis) involving the primary tumor and nodal volumes. Our results show that NP produces better quality solutions than the alternative considered methods.

  14. Direct-aperture optimization applied to selection of beam orientations in intensity-modulated radiation therapy

    Science.gov (United States)

    Bedford, J. L.; Webb, S.

    2007-01-01

    Direct-aperture optimization (DAO) was applied to iterative beam-orientation selection in intensity-modulated radiation therapy (IMRT), so as to ensure a realistic segmental treatment plan at each iteration. Nested optimization engines dealt separately with gantry angles, couch angles, collimator angles, segment shapes, segment weights and wedge angles. Each optimization engine performed a random search with successively narrowing step sizes. For optimization of segment shapes, the filtered backprojection (FBP) method was first used to determine desired fluence, the fluence map was segmented, and then constrained direct-aperture optimization was used thereafter. Segment shapes were fully optimized when a beam angle was perturbed, and minimally re-optimized otherwise. The algorithm was compared with a previously reported method using FBP alone at each orientation iteration. An example case consisting of a cylindrical phantom with a hemi-annular planning target volume (PTV) showed that for three-field plans, the method performed better than when using FBP alone, but for five or more fields, neither method provided much benefit over equally spaced beams. For a prostate case, improved bladder sparing was achieved through the use of the new algorithm. A plan for partial scalp treatment showed slightly improved PTV coverage and lower irradiated volume of brain with the new method compared to FBP alone. It is concluded that, although the method is computationally intensive and not suitable for searching large unconstrained regions of beam space, it can be used effectively in conjunction with prior class solutions to provide individually optimized IMRT treatment plans.

  15. Flattening Filter Free vs. Flattened Beams for Lung Stereotactic Body Radiation Therapy.

    Science.gov (United States)

    Annede, Pierre; Darreon, Julien; Benkemouche, Ahcene; Valdenaire, Simon; Tyran, Marguerite; Kaeppelin, Bertrand; Macagno, Alban; Barrou, Julien; Cagetti, Leonel Varela; Favrel, Veronique; Moureau-Zabotto, Laurence; Gonzague, Laurence; Fau, Pierre; Chargari, Cyrus; Tallet, Agnes; Salem, Naji

    2017-09-01

    To assess the clinical impact of high dose rate stereotactic body radiation therapy (SBRT) in patients with lung neoplastic lesions. From January 2014 to June 2016, a single-center retrospective analysis was performed including all patients treated by either flattening filter free (FFF) beams or flattening filter beams (FF) three-dimensional (3D) SBRT for lung neoplastic lesions. A total of 99 SBRT were performed on 75 patients. Among these, 29 SBRT were performed using a FFF technique while 70 other SBRT were done using a FF technique. Median follow-up time was 12.9 months. Overall, no difference between the two groups was found except for the mean beam on time which was reduced by 3.3 to 0.9 minutes in the FFF group (p<0.001). We report a low toxicity rate and a shortened beam on time in patients treated with 3D FFF SBRT for lung neoplastic lesions. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  16. Experimental observations of nonlinearly enhanced 2omega-UH electromagnetic radiation excited by steady-state colliding electron beams

    Science.gov (United States)

    Intrator, T.; Hershkowitz, N.; Chan, C.

    1984-01-01

    Counterstreaming large-diameter electron beams in a steady-state laboratory experiment are observed to generate transverse radiation at twice the upper-hybrid frequency (2omega-UH) with a quadrupole radiation pattern. The electromagnetic wave power density is nonlinearly enhanced over the power density obtained from a single beam-plasma system. Electromagnetic power density scales exponentially with beam energy and increases with ion mass. Weak turbulence theory can predict similar (but weaker) beam energy scaling but not the high power density, or the predominance of the 2omega-UH radiation peak over the omega-UH peak. Significant noise near the upper-hybrid and ion plasma frequencies is also measured, with normalized electrostatic wave energy density W(ES)/n(e)T(e) approximately 0.01.

  17. Radiation-Induced Centers in Lead Silicate Glasses Irradiated by Stationary and Pulsed Electron Beams

    Science.gov (United States)

    Zhidkov, I. S.; Zatsepin, A. F.; Konev, S. F.; Cholakh, S. O.

    2015-08-01

    Radiation-induced centers formed in heavy flint glasses irradiated by electron beams are investigated by the methods of optical and EPR spectroscopy. It is revealed that stable and short-living optical absorption centers of close natures are formed under irradiation by fast electrons. A correlation is established between the stable optical absorption bands and the EPR signals interpreted as signals of the (Pb2+)/h+ hole centers. The shortliving color centers are formed due to short-term distortion of the O-Pb bonds, and the stable centers are formed due to the spatial separation, thermalization, and subsequent stabilization of excited electrons and holes in tails of the localized states. Irradiation by electron beams leads to a change in the spectral characteristics of the fundamental absorption edge and, in particular, of the Urbach energy that determines the degree of structural disorder.

  18. Radiation damage study on diamond sensors of the ALICE Beam Condition Monitoring system

    CERN Document Server

    Vai, Ilaria

    2013-01-01

    The ALICE Beam Monitoring System has been developed with the aim of detecting beam failures that can affect the experimental region. It is composed of synthetic diamonds as detector, a material that is particularly adapt to harsh radiation environment. However some sensors have shown an increase in the noise in the last year of operation. For this reason, I have developed a station to study the working parameters of the diamond sensors used in this system, in order to check their conditions. I've found an increase of the dark current of almost all the sensors and, in particular, the sensors of the system BCM-A seem to have suffered a greater damage than the others.

  19. The potential of proton beam radiation therapy in intracranial and ocular tumours

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, Erik [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Bjelkengren, Goeran [Univ. Hospital, Malmoe (Sweden). Dept. of Oncology; Glimelius, Bengt [Karolinska Inst., Stockholm (Sweden). Dept. of Oncology and Pathology; Akademiska sjukhuset, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology

    2005-12-01

    A group of oncologists and hospital physicists have estimated the number of patients in Sweden suitable for proton beam therapy. The estimations have been based on current statistics of tumour incidence, number of patients potentially eligible for radiation treatment, scientific support from clinical trials and model dose planning studies and knowledge of the dose-response relations of different tumours and normal tissues. In intracranial benign and malignant tumours, it is estimated that between 130 and 180 patients each year are candidates for proton beam therapy. Of these, between 50 and 75 patients have malignant glioma, 30-40 meningeoma, 20-25 arteriovenous malformations, 20-25 skull base tumours and 10-15 pituitary adenoma. In addition, 15 patients with ocular melanoma are candidates.

  20. Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics.

    Science.gov (United States)

    Signorelli, Luca; Patcas, Raphael; Peltomäki, Timo; Schätzle, Marc

    2016-01-01

    The aim of this study was to determine radiation doses of different cone-beam computed tomography (CBCT) scan modes in comparison to a conventional set of orthodontic radiographs (COR) by means of phantom dosimetry. Thermoluminescent dosimeter (TLD) chips (3 × 1 × 1 mm) were used on an adult male tissue-equivalent phantom to record the distribution of the absorbed radiation dose. Three different scanning modes (i.e., portrait, normal landscape, and fast scan landscape) were compared to CORs [i.e., conventional lateral (LC) and posteroanterior (PA) cephalograms and digital panoramic radiograph (OPG)]. The following radiation levels were measured: 131.7, 91, and 77 μSv in the portrait, normal landscape, and fast landscape modes, respectively. The overall effective dose for a COR was 35.81 μSv (PA: 8.90 μSv; OPG: 21.87 μSv; LC: 5.03 μSv). Although one CBCT scan may replace all CORs, one set of CORs still entails 2-4 times less radiation than one CBCT. Depending on the scan mode, the radiation dose of a CBCT is about 3-6 times an OPG, 8-14 times a PA, and 15-26 times a lateral LC. Finally, in order to fully reconstruct cephalograms including the cranial base and other important structures, the CBCT portrait mode must be chosen, rendering the difference in radiation exposure even clearer (131.7 vs. 35.81 μSv). Shielding radiation-sensitive organs can reduce the effective dose considerably. CBCT should not be recommended for use in all orthodontic patients as a substitute for a conventional set of radiographs. In CBCT, reducing the height of the field of view and shielding the thyroid are advisable methods and must be implemented to lower the exposure dose.

  1. Reduction of radiation exposure by lead curtain shielding in dedicated extremity cone beam CT.

    Science.gov (United States)

    Lee, C-H; Ryu, J H; Lee, Y-H; Yoon, K-H

    2015-06-01

    A dedicated extremity cone beam CT (CBCT) was introduced recently, and is rapidly becoming an attractive modality for extremity imaging. This study aimed to evaluate the effectiveness of a curtain-shaped lead shielding in reducing the exposure of patients to scattered radiation in dedicated extremity CBCT. A dedicated extremity CBCT scanner was used. The lead shielding curtain was 42 × 60 cm with 0.5-mm lead equivalent. Scattered radiation dose from CBCT was measured using thermoluminescence dosimetry chips at 20 points, at different distances and directions from the CT gantry. Two sets of scattered radiation dose measurements were performed before and after installation of curtain-shaped lead shield, and the percentage reduction in dose in air was calculated. Mean radiation exposure dose at measured points was 34.46 ± 48.40 μGy without curtains and 9.67 ± 4.53 μGy with curtains, exhibiting 71.94% reduction (p = 0.000). The use of lead shielding curtains significantly reduced scattered radiation at 0.5, 1.0 and 1.5 m from the CT gantry, with percent reductions of 84.8%, 58.0% and 35.5%, respectively (p = 0.000, 0.000 and 0.002). The percent reduction in the diagonal (+45°, -45°) and vertical forward (0°) directions were 86.3%, 83.1% and 77.7%, respectively, and were statistically significant (p = 0.029, 0.020 and 0.041). Shielding with lead curtains suggests an easy and effective method for reducing patient exposure to radiation in extremity CBCT imaging. Lead shielding curtains are an effective technique to reduce scattered radiation dose in dedicated extremity CBCT, with higher dose reduction closer to the gantry opening.

  2. Finite element analysis on electron beam brazing temperature and stresses of stainless steel radiator

    Institute of Scientific and Technical Information of China (English)

    Chen Furong; Liu Jun; Xie Ruijun; Liu Fangjun; Hu Gang

    2006-01-01

    Based on thermal-elasto-plastic finite element theory, a two-dimensional finite element model for calculating electron beam brazing temperature and residual stress fields of stainless steel radiator are presented.The distributions of temperature and residual stress are studied.The results showed that temperature distribution on brazing surface is rather uniform, ranging from 1026 ℃ to 1090 ℃.The residual stresses are varied from initial compressive to tensile , and the variation of residual stress is very little in total zone of brazing surface.

  3. Use of E-beam radiation to eliminate Listeria monocytogenes from surface mould cheese.

    Science.gov (United States)

    Velasco, Raquel; Ordóñez, Juan A; Cambero, M Isabel; Cabeza, M Concepción

    2015-03-01

    Camembert and Brie soft cheese varieties were subjected to E-beam irradiation as a sanitation treatment. The effects of treatments on microbiota and selected physicochemical properties were also studied. The absorbed doses required to meet the food safety objective (FSO) according to EU and USDA criteria for Listeria monocytogenes were 1.27 and 2.59 kGy, respectively. The bacterial load, mainly lactic acid bacteria, was reduced by the treatment but injured cells were recovered during storage at 14°C. The radiation treatment gave rise to negligible changes in the pH and water activity at doses required to achieve microbial safety.

  4. Tailoring of Highly Intense THz Radiation Through High Brightness Electron Beams Longitudinal Manipulation

    Directory of Open Access Journals (Sweden)

    Flavio Giorgianni

    2016-02-01

    Full Text Available The ultra-short electron beams, produced through the velocity bunching compression technique at the SPARC_LAB test Facility (Frascati, Italy, are used to produce Coherent Transition Radiation in the terahertz (THz range. This paper reports on the main features of this THz source, which have a spectral coverage up to 5 THz, a pulse duration down to 100 fs, and an energy per pulse on the order of tens of μJ. These figures of merits open the possibility to apply this source for nonlinear and THz pump-probe experiments in Solid-State Physics and material science.

  5. RADIATION DOSIMETRY AT THE BNL HIGH FLUX BEAM REACTOR AND MEDICAL RESEARCH REACTOR.

    Energy Technology Data Exchange (ETDEWEB)

    HOLDEN,N.E.

    1999-09-10

    RADIATION DOSIMETRY MEASUREMENTS HAVE BEEN PERFORMED OVER A PERIOD OF MANY YEARS AT THE HIGH FLUX BEAM REACTOR (HFBR) AND THE MEDICAL RESEARCH REACTOR (BMRR) AT BROOKHAVEN NATIONAL LABORATORY TO PROVIDE INFORMATION ON THE ENERGY DISTRIBUTION OF THE NEUTRON FLUX, NEUTRON DOSE RATES, GAMMA-RAY FLUXES AND GAMMA-RAY DOSE RATES. THE MCNP PARTICLE TRANSPORT CODE PROVIDED MONTE CARLO RESULTS TO COMPARE WITH VARIOUS DOSIMETRY MEASUREMENTS PERFORMED AT THE EXPERIMENTAL PORTS, AT THE TREATMENT ROOMS AND IN THE THIMBLES AT BOTH HFBR AND BMRR.

  6. High-energy quasi-monoenergetic neutron fields: existing facilities and future needs

    CERN Document Server

    Pomp, S; Mayer, S; Reitz, G; Rottger, S; Silari, M; Smit, F D; Vincke, H; Yasuda, H

    2014-01-01

    The argument that well-characterised quasi-monoenergetic neutron (QMN) sources reaching into the energy domain >20 MeV are needed is presented. A brief overview of the existing facilities is given, and a list of key factors that an ideal QMN source for dosimetry and spectrometry should offer is presented. The authors conclude that all of the six QMN facilities currently in existence worldwide operate in sub-optimal conditions for dosimetry. The only currently available QMN facility in Europe capable of operating at energies >40 MeV, TSL in Uppsala, Sweden, is threatened with shutdown in the immediate future. One facility, NFS at GANIL, France, is currently under construction. NFS could deliver QMN beams up to about 30 MeV. It is, however, so far not clear if and when NFS will be able to offer QMN beams or operate with only so-called white neutron beams. It is likely that by 2016, QMN beams with energies >40 MeV will be available only in South Africa and Japan, with none in Europe.

  7. Preparation and characterization of polyethylene glycol diacrylate microgels using electron beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, Mohd Yusof [Makmal Nanoteknologi, Bahagian Teknologi Sinaran (Malaysia); Isa, Naurah Mat; Napia, Liyana M. Ali [ALURTRON, Bahagian Kemudahan Iradiasi, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia)

    2014-02-12

    The use of microemulsion in the development of nanosized gels based on polyethylene glycol diacrylate (PEGDA) is demonstrated. PEGDA was solubilized in n-heptane with use of sodium docusate (AOT) at 0.15M concentration to form reverse micelles. These micelles were than irradiated at 5, 10, 15, 20 and 25 kGy using electron beam (EB) to crosslink the entrapped polymer in the micelles. Ionizing radiation was imparted to the emulsions to generate crosslinking reaction in the micelles formed. The nanosized gels were evaluated in terms of particle diameter using dynamic light scattering (DLS) and the images of the nanosized gels were studied using transmission electron microscopy (TEM). Results show that the size and shape of the particles are influenced by concentration of PEGDA and radiation dose. This study showed that this method can be utilized to produce nanosized gels.

  8. Patient radiation dose and protection from cone-beam computed tomography.

    Science.gov (United States)

    Li, Gang

    2013-06-01

    After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from 19 µSv to 1073 µSv and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

  9. Patient radiation dose and protection from cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Gang [Peking University School and Hospital of Stomatology, Beijing (China)

    2013-06-15

    After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from 19 {mu}Sv to 1073 {mu}Sv and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

  10. Preparation and characterization of polyethylene glycol diacrylate microgels using electron beam radiation

    Science.gov (United States)

    Hamzah, Mohd Yusof; Isa, Naurah Mat; Napia, Liyana M. Ali

    2014-02-01

    The use of microemulsion in the development of nanosized gels based on polyethylene glycol diacrylate (PEGDA) is demonstrated. PEGDA was solubilized in n-heptane with use of sodium docusate (AOT) at 0.15M concentration to form reverse micelles. These micelles were than irradiated at 5, 10, 15, 20 and 25 kGy using electron beam (EB) to crosslink the entrapped polymer in the micelles. Ionizing radiation was imparted to the emulsions to generate crosslinking reaction in the micelles formed. The nanosized gels were evaluated in terms of particle diameter using dynamic light scattering (DLS) and the images of the nanosized gels were studied using transmission electron microscopy (TEM). Results show that the size and shape of the particles are influenced by concentration of PEGDA and radiation dose. This study showed that this method can be utilized to produce nanosized gels.

  11. Numerical treatment of retarded radiation effects from high brightness electron beams

    Directory of Open Access Journals (Sweden)

    A. R. Rossi

    2009-10-01

    Full Text Available A form is given of the retarded electric field and magnetic induction generated by the motion of a charged particle that expresses these fields as integrals of the retarded charge density only, with kernels depending on the charge velocity and acceleration fields. In the case of a single pointlike charge, the usual Liénard-Wiechert fields follow very easily. The set of equations for the dynamics of particles in assigned electromagnetic fields with the self-consistent field is written and integrated. The code Retar for the dynamics of charged particles in external and self-consistent fields is described and a few examples of benchmark are proposed. As a physical application, the case of an electron beam moving in a bending magnetic dipole is examined, and the radiation produced analyzed, in order to characterize a therahertz radiation source.

  12. Influence of nuclear radiation and laser beams on optical fibers and components

    Directory of Open Access Journals (Sweden)

    Pantelić Slađana N.

    2011-01-01

    Full Text Available The influence of nuclear radiation and particles has been the object of investigation for a long time. For new materials and systems the research should be continued. Human activities in various environments, including space, call for more detailed research. The role of fibers in contemporary communications, medicine, and industry increases. Fibers, their connections and fused optics components have one type of tasks - the transmission of information and power. The other type of tasks is reserved for fiber lasers: quantum generators and amplifiers. The third type of tasks is for fiber sensors, including high energy nuclear physics. In this paper we present some chosen topics in the mentioned areas as well as our experiments with nuclear radiation and laser beams to fiber and bulk materials of various nature (glass, polymer, metallic, etc..

  13. Noncoplanar Beam Angle Class Solutions to Replace Time-Consuming Patient-Specific Beam Angle Optimization in Robotic Prostate Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Linda, E-mail: l.rossi@erasmusmc.nl; Breedveld, Sebastiaan; Aluwini, Shafak; Heijmen, Ben

    2015-07-15

    Purpose: To investigate development of a recipe for the creation of a beam angle class solution (CS) for noncoplanar prostate stereotactic body radiation therapy to replace time-consuming individualized beam angle selection (iBAS) without significant loss in plan quality, using the in-house “Erasmus-iCycle” optimizer for fully automated beam profile optimization and iBAS. Methods and Materials: For 30 patients, Erasmus-iCycle was first used to generate 15-, 20-, and 25-beam iBAS plans for a CyberKnife equipped with a multileaf collimator. With these plans, 6 recipes for creation of beam angle CSs were investigated. Plans of 10 patients were used to create CSs based on the recipes, and the other 20 to independently test them. For these tests, Erasmus-iCycle was also used to generate intensity modulated radiation therapy plans for the fixed CS beam setups. Results: Of the tested recipes for CS creation, only 1 resulted in 15-, 20-, and 25-beam noncoplanar CSs without plan deterioration compared with iBAS. For the patient group, mean differences in rectum D{sub 1cc}, V{sub 60GyEq}, V{sub 40GyEq}, and D{sub mean} between 25-beam CS plans and 25-beam plans generated with iBAS were 0.2 ± 0.4 Gy, 0.1% ± 0.2%, 0.2% ± 0.3%, and 0.1 ± 0.2 Gy, respectively. Differences between 15- and 20-beam CS and iBAS plans were also negligible. Plan quality for CS plans relative to iBAS plans was also preserved when narrower planning target volume margins were arranged and when planning target volume dose inhomogeneity was decreased. Using a CS instead of iBAS reduced the computation time by a factor of 14 to 25, mainly depending on beam number, without loss in plan quality. Conclusions: A recipe for creation of robust beam angle CSs for robotic prostate stereotactic body radiation therapy has been developed. Compared with iBAS, computation times decreased by a factor 14 to 25. The use of a CS may avoid long planning times without losses in plan quality.

  14. Effects of electron-beam radiation on nutritional parameters of Portuguese chestnuts (Castanea sativa Mill.).

    Science.gov (United States)

    Carocho, Márcio; Barreira, João C M; Antonio, Amilcar L; Bento, Albino; Kaluska, Iwona; Ferreira, Isabel C F R

    2012-08-08

    Chestnuts are a widely consumed fruit around the world, with Portugal being the fourth biggest producer in Europe. Storage of these nuts is an important step during processing, and the most widely used fumigant was banned in the European Union under the Montreal Protocol because of its toxicity. Recently, radiation has been introduced as a cheap and clean conservation method. Previous studies of our research group proved that γ radiation had no negative effect on the nutritional value of chestnuts; in fact, storage time had a much bigger influence on the chestnut quality. In the present study, we report the effect of a less ionizing radiation, electron beam, with doses of 0, 0.5, 1, 3, and 6 kGy in the nutritional value of chestnuts (ash, energy, fatty acids, sugars, and tocopherols), previously stored at 4 °C for 0, 30, and 60 days. The storage time seemed to reduce fat and energetic values but reported a tendency for higher values of dry matter. With regard to fatty acids, there was a higher detected quantity of C20:2 in non-irradiated samples and four fatty acids were only detected in trace quantities (C6:0, C8:0, C10:0, and C12:0). γ-Tocopherol decreased during storage time but did not alter its quantity for all of the radiation doses (as like α-, β-, and δ-tocopherol); in fact, these compounds were present in higher concentrations in the irradiated samples. Sucrose and total sugars were lower in non-irradiated samples, and raffinose was only detected in irradiated samples. Electron-beam irradiation seems to be a suitable methodology, because the effects on chemical and nutritional composition are very low, while storage time seems to be quite important in chestnut deterioration.

  15. Thermalization of monoenergetic neutrons in a concrete room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Iniguez, M.P.; Martin M, A. [Universidad de Valladolid, (Spain)

    2006-07-01

    The thermalization of neutrons from monoenergetic neutron sources in a concrete room has been studied. During calibration of neutron detectors it is mandatory to make corrections due to neutron scattering produced by the room walls, therefore this factor must be known in advance. The scattered neutrons are thermalized and produce a neutron field that is directly proportional to source strength and inversely proportional to room total wall-surfaces, the proportional coefficient has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for 150, 200 and 300 cm-radius spherical cavity, where monoenergetic neutrons were located at the center, along the spherical cavity radius neutron spectra were calculated at several source-to-detector distances inside the cavity. The obtained coefficient is almost three times larger than the factor normally utilized. (Author)

  16. Evaluation of kinetic parameters of PAN fibre modified by electron beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Giovedi, Claudia; Arruda, Clarissa P. Zelinschi de; Carolino, Ana Claudia V., E-mail: giovedi@ctmsp.mar.mil.b [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Dept. de Tecnologia do Combustivel. Lab. de Caracterizacao de Materiais; Machado, Luci D.B.; Pino, Eddy S., E-mail: lmachado@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Carbon fibers used for structural application are about 90% based on polyacrylonitrile (PAN) precursors due to their physical and mechanical properties. The thermal process is the conventional way to obtain a carbon fiber from PAN precursors. However, the use of ionizing radiation is given as an alternative technology to improve the physical and mechanical properties of the resulting carbon fiber. The aim of this paper was to obtain kinetic parameters (activation energy, conversion and isoconversion data) from DSC curves of PAN fibers irradiated with electron beam (EB) at different doses using the software Model Free Kinetics. The EB irradiation doses applied were: 0.2; 0.4; 0.6; 0.8; 1.0 and 1.2 MGy. The effect of ionizing radiation was evaluated by the thermal behavior of PAN precursors studied by Differential Scanning Calorimetry (DSC), which presents an exothermic peak in the range of 200 deg C to 400 deg C, depending on the experimental conditions of the DSC measurements. The obtained results showed that non-irradiated PAN fiber needs higher temperatures or longer reaction times to reach the same conversion degrees of the irradiated PAN fibers. Among the irradiated fibers, the reaction times decrease as a function of the radiation dose applied. However, the most important changes were observed for doses up to 0.4 MGy. The experimental results indicate that the EB radiation induces modification in the PAN fibers, which became them more liable in the oxidation process. (author)

  17. One-dimensional carbon nanostructures for terahertz electron-beam radiation

    Science.gov (United States)

    Tantiwanichapan, Khwanchai; Swan, Anna K.; Paiella, Roberto

    2016-06-01

    One-dimensional carbon nanostructures such as nanotubes and nanoribbons can feature near-ballistic electronic transport over micron-scale distances even at room temperature. As a result, these materials provide a uniquely suited solid-state platform for radiation mechanisms that so far have been the exclusive domain of electron beams in vacuum. Here we consider the generation of terahertz light based on two such mechanisms, namely, the emission of cyclotronlike radiation in a sinusoidally corrugated nanowire (where periodic angular motion is produced by the mechanical corrugation rather than an externally applied magnetic field), and the Smith-Purcell effect in a rectilinear nanowire over a dielectric grating. In both cases, the radiation properties of the individual charge carriers are investigated via full-wave electrodynamic simulations, including dephasing effects caused by carrier collisions. The overall light output is then computed with a standard model of charge transport for two particularly suitable types of carbon nanostructures, i.e., zigzag graphene nanoribbons and armchair single-wall nanotubes. Relatively sharp emission peaks at geometrically tunable terahertz frequencies are obtained in each case. The corresponding output powers are experimentally accessible even with individual nanowires, and can be scaled to technologically significant levels using array configurations. These radiation mechanisms therefore represent a promising paradigm for light emission in condensed matter, which may find important applications in nanoelectronics and terahertz photonics.

  18. Acoustic radiation force on a sphere in a progressive and standing zero-order quasi-Bessel-Gauss beam.

    Science.gov (United States)

    Jiang, Chen; Liu, Xiaozhou; Liu, Jiehui; Mao, Yiwei; Marston, Philip L

    2017-04-01

    By means of series expansion theory, the incident quasi-Bessel-Gauss beam is expanded using spherical harmonic functions, and the beam coefficients of the quasi-Bessel-Gauss beam are calculated. According to the theory, the acoustic radiation force function, which is the radiation force per unit energy on a unit cross-sectional surface on a sphere made of diverse materials and immersed in an ideal fluid along the propagation axis of zero-order quasi-Bessel-Gauss progressive and standing beams, is investigated. The acoustic radiation force function is calculated as a function of the spherical radius parameter ka and the half-cone angle β with different beam widths in a progressive and standing zero-order Bessel-Gauss beam. Simulation results indicate that the acoustic radiation forces with different waist radii demonstrate remarkably different features from those found in previous studies. The results are expected to be useful in potential applications such as acoustic tweezers. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. TE/TM field solver for particle beam simulations without numerical Cherenkov radiation

    Directory of Open Access Journals (Sweden)

    Igor Zagorodnov

    2005-04-01

    Full Text Available The Yee finite-difference time domain method (FDTD is commonly used in wake field and particle-in-cell simulations. However, in accelerator modeling the high energy particles can travel in vacuum faster than their own radiation. This effect is commonly referred to as numerical Cherenkov radiation and is a consequence of numerical grid dispersion. Several numerical approaches are proposed to reduce the dispersion for all angles and for a given frequency range, that justifies itself for domains big in all three directions. On the contrary, in accelerator modeling the transverse dimensions and transverse beam velocity are small, but it is extremely important to eliminate the dispersion error in the well-defined direction of the beam motion for all frequencies. In this paper we propose a new two-level economical conservative scheme for electromagnetic field calculations in three dimensions. The scheme does not have dispersion in the longitudinal direction and is staircase-free (second order convergent. Unlike the FDTD method, it is based on a “transversal-electric/transversal-magnetic” (TE/TM-like splitting of the field components in time. The scheme assures energy and charge conservation. Additionally, the usage of damping terms allows suppressing high frequency noise generated due to the transverse dispersion and the current fluctuations. The dispersion relation of the damping scheme is analyzed. As numerical examples show, the new scheme is much more accurate on the long-time scale than the conventional FDTD approach.

  20. Transverse coherence properties of X-ray beams in third-generation synchrotron radiation sources

    CERN Document Server

    Geloni, Gianluca; Schneidmiller, Evgeni; Yurkov, Mikhail

    2008-01-01

    This article describes a complete theory of spatial coherence for undulator radiation sources. Current estimations of coherence properties often assume that undulator sources are quasi-homogeneous, like thermal sources, and rely on the application of the van Cittert-Zernike theorem for calculating the degree of transverse coherence. Such assumption is not adequate when treating third generation light sources, because the vertical(geometrical) emittance of the electron beam is comparable or even much smaller than the radiation wavelength in a very wide spectral interval that spans over four orders of magnitude (from 0.1 Angstrom up to 10^3 Angstrom). Sometimes, the so-called Gaussian-Schell model, that is widely used in statistical optics in the description of partially-coherent sources, is applied as an alternative to the quasi-homogeneous model. However, as we will demonstrate, this model fails to properly describe coherent properties of X-ray beams from non-homogeneous undulator sources. As a result, a more...

  1. Ultrasonic Beam Radiation of an A0 Leaky Lamb Wave in a Plate Waveguide Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jin Ho; Joo, Young Sang; Kim, Jong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Rhee, Hui Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-05-15

    As the sodium coolant of a sodium-cooled fast reactor (SFR) is opaque to light, a conventional visual inspection cannot be used for carrying out an in-service inspection of the internal structures under a sodium level. An ultrasonic wave should be applied for an under-sodium viewing of the internal structures in a reactor vessel. Immersion sensors and waveguide sensors have been applied to the under-sodium visualization. The immersion sensor has a precise imaging capability, but may have high temperature restrictions and an uncertain life. The waveguide sensor has the advantages of a long lifetime and stable application. Recently, a new plate waveguide sensor has been developed for the versatile applications in the under-sodium viewing application. In the plate waveguide sensor, the A0 leaky Lamb wave is utilized for the long distance propagation and the effective radiation capability in a fluid. And a new technique is presented which is capable of steering an ultrasonic beam of a waveguide sensor without a mechanical movement of the sensor assembly. In this paper, the experimental study of the radiation beam profile of the A0 leaky Lamb wave in a plate waveguide sensor is carried out

  2. Intraoperative Electron-Beam Radiation Therapy for Pediatric Ewing Sarcomas and Rhabdomyosarcomas: Long-Term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Sole, Claudio V., E-mail: csole@iram.cl [Department of Radiation Oncology, Instituto de Radiomedicina, Santiago (Chile); School of Medicine, Complutense University, Madrid (Spain); Calvo, Felipe A. [School of Medicine, Complutense University, Madrid (Spain); Department of Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Polo, Alfredo [Service of Radiation Oncology, Hospital Universitario Ramón y Cajal, Madrid (Spain); Cambeiro, Mauricio [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain); Gonzalez, Carmen [School of Medicine, Complutense University, Madrid (Spain); Service of Radiation Oncology, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Desco, Manuel [School of Medicine, Complutense University, Madrid (Spain); Department of Experimental Surgery and Medicine, Hospital General Universitario Gregorio Marañón, Madrid (Spain); Martinez-Monge, Rafael [Service of Radiation Oncology, Clínica Universidad de Navarra, Pamplona (Spain)

    2015-08-01

    Purpose: To assess long-term outcomes and toxicity of intraoperative electron-beam radiation therapy (IOERT) in the management of pediatric patients with Ewing sarcomas (EWS) and rhabdomyosarcomas (RMS). Methods and Materials: Seventy-one sarcoma (EWS n=37, 52%; RMS n=34, 48%) patients underwent IOERT for primary (n=46, 65%) or locally recurrent sarcomas (n=25, 35%) from May 1983 to November 2012. Local control (LC), overall survival (OS), and disease-free survival were estimated using Kaplan-Meier methods. For survival outcomes, potential associations were assessed in univariate and multivariate analyses using the Cox proportional hazards model. Results: After a median follow-up of 72 months (range, 4-310 months), 10-year LC, disease-free survival, and OS was 74%, 57%, and 68%, respectively. In multivariate analysis after adjustment for other covariates, disease status (P=.04 and P=.05) and R1 margin status (P<.01 and P=.04) remained significantly associated with LC and OS. Nine patients (13%) reported severe chronic toxicity events (all grade 3). Conclusions: A multimodal IOERT-containing approach is a well-tolerated component of treatment for pediatric EWS and RMS patients, allowing reduction or substitution of external beam radiation exposure while maintaining high local control rates.

  3. Partial Breast Radiation Therapy With Proton Beam: 5-Year Results With Cosmetic Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Bush, David A., E-mail: dbush@llu.edu [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Do, Sharon [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Lum, Sharon; Garberoglio, Carlos [Department of Surgical Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Mirshahidi, Hamid [Department of Medical Oncology, Loma Linda University Medical Center, Loma Linda, California (United States); Patyal, Baldev; Grove, Roger; Slater, Jerry D. [Department of Radiation Oncology, Loma Linda University Medical Center, Loma Linda, California (United States)

    2014-11-01

    Purpose: We updated our previous report of a phase 2 trial using proton beam radiation therapy to deliver partial breast irradiation (PBI) in patients with early stage breast cancer. Methods and Materials: Eligible subjects had invasive nonlobular carcinoma with a maximal dimension of 3 cm. Patients underwent partial mastectomy with negative margins; axillary lymph nodes were negative on sampling. Subjects received postoperative proton beam radiation therapy to the surgical bed. The dose delivered was 40 Gy in 10 fractions, once daily over 2 weeks. Multiple fields were treated daily, and skin-sparing techniques were used. Following treatment, patients were evaluated with clinical assessments and annual mammograms to monitor toxicity, tumor recurrence, and cosmesis. Results: One hundred subjects were enrolled and treated. All patients completed the assigned treatment and were available for post-treatment analysis. The median follow-up was 60 months. Patients had a mean age of 63 years; 90% had ductal histology; the average tumor size was 1.3 cm. Actuarial data at 5 years included ipsilateral breast tumor recurrence-free survival of 97% (95% confidence interval: 100%-93%); disease-free survival of 94%; and overall survival of 95%. There were no cases of grade 3 or higher acute skin reactions, and late skin reactions included 7 cases of grade 1 telangiectasia. Patient- and physician-reported cosmesis was good to excellent in 90% of responses, was not changed from baseline measurements, and was well maintained throughout the entire 5-year follow-up period. Conclusions: Proton beam radiation therapy for PBI produced excellent ipsilateral breast recurrence-free survival with minimal toxicity. The treatment proved to be adaptable to all breast sizes and lumpectomy cavity configurations. Cosmetic results appear to be excellent and unchanged from baseline out to 5 years following treatment. Cosmetic results may be improved over those reported with photon

  4. Effect of Neutron Radiation on Moment-Curvature Response of Reinforced Concrete Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Taehyun; Kim, Jun Yeon; Cho, Mansoon; Wu, Sangik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Kyoungsoo [Yonsei Univ., Seoul (Korea, Republic of)

    2014-05-15

    Reinforced concrete (RC) is a composite material in which concrete resists compression and steel bars as reinforcement are embedded in tensile regions to counteract the concrete's relative low tensile strength and ductility. RC is commonly used as a biological shield and as a load carrying support for a reactor vessel and, if any, changes in the mechanical properties can be particular significant for long-term irradiation. The highlights can be considered as the most critical due to its load bearing in the RC design. This study investigated the moment-curvature response of an RC beam with incremental neutron radiation. The RC structure close to the reactor vessel was considered as the most critical in estimating that the total fluence for 40 years becomes about 10{sup 14} to 10{sup 18} n/cm{sup 2}. The moment-curvature response of an RC beam was investigated with the maximum neutron fluence up to 10{sup 19} n/cm{sup 2} and it shows twice the increase in ultimate strength, which is mainly contributed from the increased yield stress of mild steel. The RC beam response became so brittle that it may fail without large deformation as a warning. The same observation can be equally applied to other RC designs such as the column, slab, and foundation.

  5. Beam test of novel n-in-p strip sensors for high radiation environment

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T., E-mail: kubota@hep.phys.titech.ac.jp [Department of Physics, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan); Kishida, T.; Jinnouchi, O. [Department of Physics, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan); Ikegami, Y.; Unno, Y.; Terada, S.; Mitsui, S. [Institute of Particle and Nuclear Study, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Tamii, A.; Aoi, T. [Research Center of Nuclear Physics (RCNP), 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Hanagaki, K. [Department of Physics, Osaka University, Machikaneyama-cho, Toyonaka-shi, Osaka 560-0043 (Japan); Hara, K. [Institute of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba-shi, Ibaraki 305-8571 (Japan); Kimura, N. [Research Institute for Science and Engineering, Waseda University (Japan); Takashima, R. [Department of Education, Kyoto University of Education, 1 Fukakusa-Fujimori-cho, Fushimi-ku, Kyoto 612-8522 (Japan); Takubo, Y. [Institute of Particle and Nuclear Study, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Tojo, J. [Department of Physics, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Nagai, K. [Institute of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba-shi, Ibaraki 305-8571 (Japan); Nakano, I. [Department of Physics, Okayama University, 3-1-1 Tshushima-naka, Kita-ku, Okayama-shi, Okayama 700-8530 (Japan); Yorita, K. [Research Institute for Science and Engineering, Waseda University (Japan)

    2013-12-11

    Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board ‘SEABAS’ and beam tracking telescopes whose spacial resolution is better than 5μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 10{sup 15} n{sub eq} cm{sup −2} irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 10{sup 15} n{sub eq} cm{sup −2} irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12μm in the irradiated sensors at 10{sup 15} n{sub eq} cm{sup −2}.

  6. Thermal and mechanical properties of blends of LDPE and EVA crosslinked by electron beam radiation

    Science.gov (United States)

    Borhani Zarandi, Mahmoud; Amrollahi Bioki, Hojjat

    2013-08-01

    Low density polyethylene (LDPE) blends with different percentages of ethylene vinyl acetate (EVA) irradiated with 10 MeV electron beam in the range of 50-250 kGy at room temperature. The effect of irradiation and EVA content on the mechanical and thermal properties of LDPE was studied. It was revealed that for all blends increasing the applied dose up to 150 kGy would result in decrease in the specific heat capacity (cp) and thermal conductivity (k) of LDPE and then raised slightly with further increased in radiation doses. The gel content showed that under the irradiation, the crosslinking density at each irradiation dose depends almost on the amorphous portions of the LDPE/EVA. The mechanical properties of LDPE/EVA blends were found to be influenced by the electron beam irradiation and EVA content. It can be deduced that the mechanical properties of LDPE are improved by blending with EVA and irradiated by electron beam. Fourier transform infrared (FTIR) spectroscopy was used to characterize the structure of LDPE. Result indicates small variation in crystalline content, which could be increased or decreased on the formation of important bond groups.

  7. Improving the Fermilab Booster Notching Efficiency, Beam Losses and Radiation Levels

    CERN Document Server

    Rakhno, I L; Mokhov, N V; Sidorov, V I; Tropin, I S

    2012-01-01

    Currently a fast vertical 1.08-m long kicker (notcher) located in the Fermilab Booster Long-5 straight section is used to remove 3 out of 84 circulating bunches after injection to generate an abort gap. With magnetic field of 72.5 Gauss it removes only 87% of the 3-bunch intensity at 400 MeV, with 75% loss on pole tips of the focusing Booster magnets, 11% on the Long-6 collimators, and 1% in the rest of the ring. We propose to improve the notching efficiency and reduce beam loss in the Booster by using two horizontal kickers in the Long-12 section. The STRUCT calculations show that using such horizontal notchers, one can remove up to 99% of the 3-bunch intensity at 400-700 MeV, directing 96% of it to a new beam dump at the Long-13 section. This fully decouples notching and collimation. The beam dump absorbs most of the impinging proton energy in its jaws. The latter are encapsulated into an appropriate radiation shielding that reduces impact on the machine components, personnel and environment to the tolerabl...

  8. Dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources

    Science.gov (United States)

    Barty, Christopher P.J.

    2013-02-05

    A dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources includes a detector arrangement consists of three detectors downstream from the object under observation. The latter detector, which operates as a beam monitor, is an integrating detector that monitors the total beam power arriving at its surface. The first detector and the middle detector each include an integrating detector surrounding a foil. The foils of these two detectors are made of the same atomic material, but each foil is a different isotope, e.g., the first foil may comprise U235 and second foil may comprise U238. The integrating detectors surrounding these pieces of foil measure the total power scattered from the foil and can be similar in composition to the final beam monitor. Non-resonant photons will, after calibration, scatter equally from both foils.

  9. Using electron beam radiation to simulate the dose distribution for whole body solar particle event proton exposure.

    Science.gov (United States)

    Cengel, Keith A; Diffenderfer, Eric S; Avery, Stephen; Kennedy, Ann R; McDonough, James

    2010-11-01

    As a part of the near solar system exploration program, astronauts may receive significant total body proton radiation exposures during a solar particle event (SPE). In the Center for Acute Radiation Research (CARR), symptoms of the acute radiation sickness syndrome induced by conventional radiation are being compared to those induced by SPE-like proton radiation, to determine the relative biological effectiveness (RBE) of SPE protons. In an SPE, the astronaut's whole body will be exposed to radiation consisting mainly of protons with energies below 50 MeV. In addition to providing for a potentially higher RBE than conventional radiation, the energy distribution for an SPE will produce a relatively inhomogeneous total body dose distribution, with a significantly higher dose delivered to the skin and subcutaneous tissues than to the internal organs. These factors make it difficult to use a (60)Co standard for RBE comparisons in our experiments. Here, the novel concept of using megavoltage electron beam radiation to more accurately reproduce both the total dose and the dose distribution of SPE protons and make meaningful RBE comparisons between protons and conventional radiation is described. In these studies, Monte Carlo simulation was used to determine the dose distribution of electron beam radiation in small mammals such as mice and ferrets as well as large mammals such as pigs. These studies will help to better define the topography of the time-dose-fractionation versus biological response landscape for astronaut exposure to an SPE.

  10. Performance of a plasma window for a high pressure differentially pumped deuterium gas target for mono-energetic fast neutron production - Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Beer, A. de; Hershcovitch, A.; Franklyn, C.B.; Straaten, S. van; Guzek, J. E-mail: jguzek@debeers.co.za

    2000-09-01

    The reactions D(d,n){sup 3}He and T(d,n){sup 4}He are frequently used for production of the mono-energetic or quasi mono-energetic neutron beams but successful applications are often limited by the intensity of the generated neutron beams. The development of a suitable neutron source for such applications as studies of resonance phenomena, fast neutron radiography, selective fast neutron activation, explosives and contraband detection and others, depends on the output ion current of the accelerator and the design of the target system. A practical solution for a high pressure gas target was previously developed and successfully implemented at De Beers Diamond Research Laboratory in Johannesburg (Guzek et al., 1999), but it is limited to applications using low (<20%) duty cycle accelerators. The concept of a plasma window for the separation of a high pressure gas target region and accelerator vacuum, that was originally developed by Hershcovitch (1995) for electron welding applications, may be suitable for operation with continuous wave accelerators at high particle current output. Preliminary test results, which have been performed with various gases (argon, helium and deuterium), indicate that implementation of the plasma window into a gas target system, for the production of intense mono-energetic fast neutron beams will be achievable.

  11. Measurement of stability of electron beam generated by laser-driven plasma-based accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, S; Miura, E; Koyama, K; Kato, S [National Institute of Advanced Industrial Science and Technology, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)], E-mail: shi-masuda@aist.go.jp

    2008-05-01

    Quasi-monoenergetic electron beams with the energy of 30-80 MeV and large number of electrons more than 10{sup 8} were produced by focusing a 8TW, 50 fs Ti:sapphire laser pulse onto 1.6-1.9 x 10{sup 19} cm{sup -3} plasmas. Stability of the quasi-monoenergetic electron beam generation was evaluated using an in-situ observation system for the electron beam diagnostics.

  12. The development and role of megavoltage cone beam computerized tomography in radiation oncology

    Science.gov (United States)

    Morin, Olivier

    External beam radiation therapy has now the ability to deliver doses that conform tightly to a tumor volume. The steep dose gradients planned in these treatments make it increasingly important to reproduce the patient position and anatomy at each treatment fraction. For this reason, considerable research now focuses on in-room three-dimensional imaging. This thesis describes the first clinical megavoltage cone beam computed tomography (MVCBCT) system, which utilizes a conventional linear accelerator equipped with an amorphous silicon flat panel detector. The document covers the system development and investigation of its clinical applications over the last 4-5 years. The physical performance of the system was evaluated and optimized for soft-tissue contrast resolution leading to recommendations of imaging protocols to use for specific clinical applications and body sites. MVCBCT images can resolve differences of 5% in electron density for a mean dose of 9 cGy. Hence, the image quality of this system is sufficient to differentiate some soft-tissue structures. The absolute positioning accuracy with MVCBCT is better than 1 mm. The accuracy of isodose lines calculated using MVCBCT images of head and neck patients is within 3% and 3 mm. The system shows excellent stability in image quality, CT# calibration, radiation exposure and absolute positioning over a period of 8 months. A procedure for MVCBCT quality assurance was developed. In our clinic, MVCBCT has been used to detect non rigid spinal cord distortions, to position a patient with a paraspinous tumor close to metallic hardware, to position prostate cancer patients using gold markers or soft-tissue landmarks, to monitor head and neck anatomical changes and their dosimetric consequences, and to complement the convention CT for treatment planning in presence of metallic implants. MVCBCT imaging is changing the clinical practice of our department by increasingly revealing patient-specific errors. New verification

  13. Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI

    DEFF Research Database (Denmark)

    Zimmermann, S. J.; Rowshanfarzad, P.; Ebert, M. A.

    2015-01-01

    radiation isocentre prior to routine use of the cone-beam CT system. The isocentre determination method used in the XVI software is not available to users. The aim of this work is to perform an independent evaluation of the Elekta XVI 4.5 software for isocentre verification with focus on the robustness......Purpose/Objective: Most modern radiotherapy treatments are based on cone-beam CT images to ensure precise positioning of the patient relative to the linac. This requires alignment of the cone-beam CT system to the linac MV radiation isocentre. Therefore, it is important to precisely localize the MV......) and the radiation field centre (RFC) is calculated. A software package was developed for accurate calculation of the linac isocentre position. This requires precise determination of the position of the ball bearing and the RFC. Results: Data were acquired for 6 MV, 18 MV and flattening filter free (FFF) 6 MV FFF...

  14. Simulation of 3-D radiation beam patterns propagated through a planar interface from ultrasonic phased array transducers.

    Science.gov (United States)

    Song, Sung-Jin; Kim, Chang-Hwan

    2002-05-01

    Phased array transducers are quite often mounted on solid wedges with specific angles in many practical ultrasonic inspections of thin plates phased array techniques with testing set-up, it is essential to have thorough understanding on the characteristics of radiation beam pattern produced in the interrogated medium. To address such a need, this paper proposes a systematic way to calculate full 3-D radiation beam patterns produced in the interrogated solid medium by phased array transducers mounted on a solid wedge. In order to investigate the characteristics of radiation beam patterns in steel, simulation is carried out for 7.5 MHz array transducers mounted on an acrylic wedge with the angle of 15.45 degrees with various of steering angles and/or focal planes.

  15. Whole acute toxicity removal from industrial and domestic effluents treated by electron beam radiation: emphasis on anionic surfactants

    Science.gov (United States)

    Moraes, M. C. F.; Romanelli, M. F.; Sena, H. C.; Pasqualini da Silva, G.; Sampa, M. H. O.; Borrely, S. I.

    2004-09-01

    Electron beam radiation has been applied to improve real industrial and domestic effluents received by Suzano wastewater treatment plant. Radiation efficacy has been evaluated as toxicity reduction, using two biological assays. Three sites were sampled and submitted for toxicity assays, anionic surfactant determination and electron beam irradiation. This paper shows the reduction of acute toxicity for both test-organisms, the marine bacteria Vibrio fischeri and the crustacean Daphnia similis. The raw toxic effluents exibitted from 0.6 ppm up to 11.67 ppm for anionic surfactant before being treated by the electron beam. Radiation processing resulted in reduction of the acute toxicity as well as surfactant removal. The final biological effluent was in general less toxic than other sites but the presence of anionic surfactants was evidenced.

  16. A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Depauw, Nicolas, E-mail: ndepauw@partners.org [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Centre for Medical Radiation Physics, University of Wollongong, New South Wales (Australia); Batin, Estelle; Daartz, Julianne [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Rosenfeld, Anatoly [Centre for Medical Radiation Physics, University of Wollongong, New South Wales (Australia); Adams, Judith; Kooy, Hanne; MacDonald, Shannon; Lu, Hsiao-Ming [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2015-02-01

    Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields

  17. Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations

    Directory of Open Access Journals (Sweden)

    Mancosu Pietro

    2012-02-01

    Full Text Available Abstract Purpose To report the initial institute experience in terms of dosimetric and technical aspects in stereotactic body radiation therapy (SBRT delivered using flattening filter free (FFF beam in patients with liver lesions. Methods and Materials From October 2010 to September 2011, 55 consecutive patients with 73 primary or metastatic hepatic lesions were treated with SBRT on TrueBeam using FFF beam and RapidArc technique. Clinical target volume (CTV was defined on multi-phase CT scans, PET/CT, MRI, and 4D-CT. Dose prescription was 75 Gy in 3 fractions to planning target volume (PTV. Constraints for organs at risk were: 700 cc of liver free from the 15 Gy isodose, Dmax max 0.1 cc 15 Gy Results Forty-three patients with a single lesion, nine with two lesions and three with three lesions were treated with this protocol. Target and organs at risk objectives were met for all patients. Mean delivery time was 2.8 ± 1.0 min. Pre-treatment plan verification resulted in a Gamma Agreement Index of 98.6 ± 0.8%. Mean on-line co-registration shift of the daily CBCT to the simulation CT were: -0.08, 0.05 and -0.02 cm with standard deviations of 0.33, 0.39 and 0.55 cm in, vertical, longitudinal and lateral directions respectively. Conclusions SBRT for liver targets delivered by means of FFF resulted to be feasible with short beam on time.

  18. Cone-Beam Computed Tomography and Radiographs in Dentistry: Aspects Related to Radiation Dose

    Directory of Open Access Journals (Sweden)

    Diego Coelho Lorenzoni

    2012-01-01

    Full Text Available Introduction. The aim of this study was to discuss the radiation doses associated with plain radiographs, cone-beam computed tomography (CBCT, and conventional computed tomography (CT in dentistry, with a special focus on orthodontics. Methods. A systematic search for articles was realized by MEDLINE from 1997–March 2011. Results. Twenty-seven articles met the established criteria. The data of these papers were grouped in a table and discussed. Conclusions. Increases in kV, mA, exposure time, and field of view (FOV increase the radiation dose. The dose for CT is greater than other modalities. When the full-mouth series (FMX is performed with round collimation, the orthodontic radiographs transmit higher dose than most of the large FOV CBCT, but it can be reduced if used rectangular collimation, showing lower effective dose than large FOV CBCT. Despite the image quality, the CBCT does not replace the FMX. In addition to the radiation dose, image quality and diagnostic needs should be strongly taken into account.

  19. A novel diamond-based beam position monitoring system for the High Radiation to Materials facility at CERN SPS

    CERN Document Server

    AUTHOR|(CDS)2092886; Höglund, Carina

    The High Radiation to Materials facility employs a high intensity pulsed beam imposing several challenges on the beam position monitors. Diamond has been shown to be a resilient material with its radiation hardness and mechanical strength, while it is also simple due to its wide bandgap removing the need for doping. A new type of diamond based beam position monitor has been constructed, which includes a hole in the center of the diamond where the majority of the beam is intended to pass through. This increases the longevity of the detectors as well as allowing them to be used for high intensity beams. The purpose of this thesis is to evaluate the performance of the detectors in the High Radiation to Materials facility for various beam parameters, involving differences in position, size, bunch intensity and bunch number. A prestudy consisting of calibration of the detectors using single incident particles is also presented. The detectors are shown to work as intended after a recalibration of the algorithm, alb...

  20. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC

    Energy Technology Data Exchange (ETDEWEB)

    Mosalaei, Homeira, E-mail: homeira.mosalaei@lhsc.on.ca [London Regional Cancer Program, London Health Science Centre, Ontario (Canada); Karnas, Scott [London Regional Cancer Program, London Health Science Centre, Ontario (Canada); University of Waterloo, Waterloo, Ontario (Canada); Shah, Sheel [University of Western Ontario, London, Ontario (Canada); Van Doodewaard, Sharon [McMaster University, Hamilton, Ontario (Canada); Foster, Tim [University of Western Ontario, London, Ontario (Canada); Chen, Jeff [London Regional Cancer Program, London Health Science Centre, Ontario (Canada); University of Waterloo, Waterloo, Ontario (Canada)

    2012-04-01

    Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields.

  1. Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Mingyao [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States); Bharat, Shyam [Philips Research North America, Briarcliff Manor, New York (United States); Michalski, Jeff M.; Gay, Hiram A. [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States); Hou, Wei-Hsien [St Louis University School of Medicine, St Louis, Missouri (United States); Parikh, Parag J., E-mail: pparikh@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, Missouri (United States)

    2013-03-15

    Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

  2. Adaptive radiation therapy for postprostatectomy patients using real-time electromagnetic target motion tracking during external beam radiation therapy.

    Science.gov (United States)

    Zhu, Mingyao; Bharat, Shyam; Michalski, Jeff M; Gay, Hiram A; Hou, Wei-Hsien; Parikh, Parag J

    2013-03-15

    Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (Dmin) with the planned Dmin to the CTV. Treatments were considered adequate if the delivered CTV Dmin is at least 95% of the planned CTV Dmin. Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: -0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A simple model of space radiation damage in GaAs solar cells

    Science.gov (United States)

    Wilson, J. W.; Stith, J. J.; Stock, L. V.

    1983-01-01

    A simple model is derived for the radiation damage of shallow junction gallium arsenide (GaAs) solar cells. Reasonable agreement is found between the model and specific experimental studies of radiation effects with electron and proton beams. In particular, the extreme sensitivity of the cell to protons stopping near the cell junction is predicted by the model. The equivalent fluence concept is of questionable validity for monoenergetic proton beams. Angular factors are quite important in establishing the cell sensitivity to incident particle types and energies. A fluence of isotropic incidence 1 MeV electrons (assuming infinite backing) is equivalent to four times the fluence of normal incidence 1 MeV electrons. Spectral factors common to the space radiations are considered, and cover glass thickness required to minimize the initial damage for a typical cell configuration is calculated. Rough equivalence between the geosynchronous environment and an equivalent 1 MeV electron fluence (normal incidence) is established.

  4. Hypofractionated external-beam radiation therapy (HEBRT versus conventional external-beam radiation (CEBRT in patients with localized prostate cancer: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Botrel TEA

    2013-03-01

    Full Text Available Tobias Engel Ayer Botrel,1 Otávio Clark,1 Antônio Carlos Lima Pompeo,2 Francisco Flávio Horta Bretas,2 Marcus Vinicius Sadi,2 Ubirajara Ferreira,2 Rodolfo Borges dos Reis21CoBEU and Evidencias, 2Comitê Brasileiro de Estudos em Uro-Oncologia – CoBEU, BrazilBackground: The purpose of this work was to conduct a systematic review and meta-analysis of all randomized controlled trials comparing the efficacy and side effect profile of hypofractionated versus conventional external-beam radiation therapy for prostate cancer.Methods: Several databases were searched, including Medline, EmBase, LiLACS, and Central. The endpoints were freedom from biochemical failure and side effects. We performed a meta-analysis of the published data. The results are expressed as the hazard ratio (HR or risk ratio (RR, with the corresponding 95% confidence interval (CI.Results: The final analysis included nine trials comprising 2702 patients. Freedom from biochemical failure was reported in only three studies and was similar in patients who received hypofractionated or conventional radiotherapy (fixed effect, HR 1.03, 95% CI 0.88–1.20; P = 0.75, with heterogeneity [χ2 = 15.32, df = 2 (P = 0.0005; I2 = 87%]. The incidence of acute adverse gastrointestinal events was higher in the hypofractionated group (fixed effect, RR 2.02, 95% CI 1.45–2.81; P < 0.0001. We also found moderate heterogeneity on this analysis [χ2 = 7.47, df = 5 (P = 0.19; I2 = 33%]. Acute genitourinary toxicity was similar among the groups (fixed effect, RR 1.19, 95% CI 0.95–1.49; P = 0.13, with moderate heterogeneity [χ2 = 5.83, df = 4 (P = 0.21; I2 = 31%]. The incidence of all late adverse events was the same in both groups (fixed effect, gastrointestinal toxicity, RR 1.17, 95% CI 0.79–1.72, P = 0.44; and acute genitourinary toxicity, RR 1.16, 95% CI 0.80–1.68, P = 0.44.Conclusion: Hypofractionated radiotherapy in localized prostate cancer was not superior to conventional radiotherapy and

  5. Comparison of the radiobiological effect of carbon ion beam therapy and conventional radiation therapy on cervical cancer.

    Science.gov (United States)

    Suzuki, Yoshiyuki; Nakano, Takashi; Ohno, Tatsuya; Oka, Kuniyuki

    2008-09-01

    Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on the 15th day. In contrast, for photon beam therapy, the p27 LI consistently decreased from the initial 19.9% to 13.7% on the 15th day. Histological effects were observably stronger under carbon than photon beam therapy, though no statistically significant difference was observed (p = 0.07 on the 5th day and p = 0.10 on the 15th day). The changes in p27 LI under carbon beam therapy were significantly different from those under photon beam therapy, which suggests important molecular differences in the radio-biological response between therapies. Further investigation is required to elucidate the clinical relevance of these putative changes and optimize the relative biological effectiveness of carbon beam to X-ray.

  6. Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer.

    Science.gov (United States)

    Cheng, Mei-Chun; Hu, Yu-Wen; Liu, Ching-Sheng; Lee, Jeun-Shenn; Huang, Pin-I; Yen, Sang-Hue; Lee, Yuh-Lin; Hsieh, Chun-Mei; Shiau, Cheng-Ying

    2014-01-01

    This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV)63Gy as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV70Gy and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV70Gy coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  7. Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Mei-Chun [Division of Radiation Oncology, Department of Oncology Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Hu, Yu-Wen; Liu, Ching-Sheng [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China); Lee, Jeun-Shenn [Division of Radiation Oncology, Department of Oncology Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Huang, Pin-I; Yen, Sang-Hue; Lee, Yuh-Lin; Hsieh, Chun-Mei [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China); Shiau, Cheng-Ying, E-mail: cyshiau@vghtpe.gov.tw [Department of Radiation Oncology, Taichung Veterans General Hospital, Taichung, Taiwan (China)

    2014-10-01

    This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV){sub 63} {sub Gy} as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV{sub 70} {sub Gy} and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV{sub 70} {sub Gy} coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC.

  8. Transfer coefficients of energy in mass for X radiation-air: the kV relation and effective energy; Coefficientes de transferencia de energia em massa para raios-X-Ar: a relacao kV e energia efetiva

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, G.J.; Sousa, C.H.S.; Peixoto, J.G.P., E-mail: gt@ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    The objective was to determine, through specific software, the mass-energy transfer coefficients by X-ray beams in air between 30-150 kV. Were generated by the Spectrum Processor program, the spectra and calculated their mass coefficients. The results behaved numerically decreasing order, ranging between 0.3733 and 0.0439 cm{sup 2}/g, inversely proportional to the voltage used and differing behavior of mono-energetic beams above 100 keV. Values align with literal definitions of the interaction of radiation with matter, being useful for dosimetry in diagnostic radiology, including for systems not using an ionization chamber. (author)

  9. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  10. The assessment of four different correction models applied to the diffuse radiation measured with a shadow ring using global and normal beam radiation measurements for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Kudish, Avraham I.; Evseev, Efim G. [Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, E D Bergmann Campus, Beer Sheva 84105 (Israel)

    2008-02-15

    The measurement of the diffuse radiation incident on a horizontal surface, a priori a straightforward task, is fraught with difficulties. It is possible to measure the diffuse radiation by three different techniques: two of which measure it directly and the third indirectly. The most accurate is the indirect one, which is based upon the concurrent measurements of the horizontal global and the normal incidence beam radiation. The disadvantage of this being the relatively expensive tracking system required for measuring the latter. The diffuse radiation can be measured directly with a pyranometer outfitted with either an occulting disk or shadow ring, which prevent the beam radiation from impinging on the pyranometer sensor. The occulting disk can provide accurate measurements of the diffuse radiation but it requires a relatively expensive sun tracking system in the east-west axis. The shadow ring is a stationary device with regard to the east-west axis and blocks the beam radiation component by creating a permanent shadow on the pyranometer sensor. The major disadvantage of the shadow ring is that it also blocks that portion of the diffuse radiation obscured by the shadow ring. This introduces a measurement error that must be corrected to account for that portion of the sky obscured by the shadow band. In addition to this geometric correction factor there is a need to correct for anisotropic sky conditions. Four correction models have been applied to the data for Beer Sheva, Israel and the results have been evaluated both graphically and statistically. An attempt has been made to score the relative performance of the models under different sky conditions. (author)

  11. Beam-machine interaction at TLEP : first evaluation and mitigation of the synchrotron radiation impact

    CERN Document Server

    Lari, L; Ferrari, A; Mereghetti, A

    2014-01-01

    In the framework of post-LHC accelerator studies, TLEP is a proposed high-luminosity circular e+e- collider, aimed at measuring the properties of the Higgs boson H(126) with unprecedented accuracy, as well as those of the W boson, the Z boson and the top quark. In order to calculate the impact of synchrotron radiation, the latter has been implemented in the FLUKA code as new source term. A first account of escaping power as a function of the vacuum chamber shielding thickness, photoneutron production, and activation has been obtained for the 80 km circumference 175 GeV (beam energy) TLEP option. Starting from a preliminary layout of the FODO cell and a possible dipole design, energy deposition simulations have been carried out, investigating the effectiveness of absorbers in the interconnections. The results provide inputs to improve the cell design and to support mechanical integration studies

  12. The influence of an extrapolation chamber over the low energy X-ray beam radiation field

    Energy Technology Data Exchange (ETDEWEB)

    Tanuri de F, M. T.; Da Silva, T. A., E-mail: mttf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The extrapolation chambers are detectors whose sensitive volume can be modified by changing the distance between the electrodes and has been widely used for beta particles primary measurement system. In this work, was performed a PTW 23392 extrapolation chamber Monte Carlo simulation, by mean the MCNPX code. Although the sensitive volume of an extrapolation chamber can be reduced to very small size, their packaging is large enough to modify the radiation field and change the absorbed dose measurements values. Experiments were performed to calculate correction factors for this purpose. The validation of the Monte Carlo model was done by comparing the spectra obtained with a CdTe detector according to the ISO 4037 criteria. Agreements smaller than 5% for half value layers, 10% for spectral resolution and 1% for mean energy, were found. It was verified that the correction factors are dependent of the X-ray beam quality. (Author)

  13. Investigation of GEM-Micromegas Detector on X-ray Beam of Synchrotron Radiation

    CERN Document Server

    Zhang, YuLian; Hu, BiTao; Fan, ShengNan; Wang, Bo; Liu, Mei; Zhang, Jian; Liu, RongGuang; Chang, GuangCai; Liu, Peng; Ouyang, Qun; Chen, YuanBo; Yi, FuTing

    2013-01-01

    To solve the discharge of the standard Bulk Micromegas and GEM detector, the GEM-Micromegas detector was developed in Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the GEM preamplification decreased the working voltage of Micromegas to reduce the effect of the discharge significantly. In the paper, the performance of detector in X-ray beam was studied at 1W2B laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. It indicated that the GEM-Micromegas detector had the energy response capability in all the energy range and it could work better than the standard Bulk-Micromegas.

  14. Development of photon beam diagnostics for VUV radiation from a SASE FEL

    CERN Document Server

    Treusch, R; Xu, W; Jastrow, U; Hahn, U; Bittner, L; Feldhaus, J

    2000-01-01

    For the proof-of-principle experiment of self-amplified spontaneous emission (SASE) at short wavelengths on the VUV FEL at DESY a multi-facetted photon beam diagnostics experiment has been developed employing new detection concepts to measure all SASE specific properties on a single pulse basis. The present setup includes instrumentation for the measurement of the energy and the angular and spectral distribution of individual photon pulses. Different types of photon detectors such as PtSi-photodiodes and fast thermoelectric detectors based on YBaCuO-films are used to cover some five orders of magnitude of intensity from the level of spontaneous emission to FEL radiation at saturation. A 1 m normal incidence monochromator in combination with a fast intensified CCD camera allows to select single photon pulses and to record the full spectrum at high resolution to resolve the fine structure due to the start-up from noise.

  15. Polarized Uniform Linear Array System: Beam Radiation Pattern, Beamforming Diversity Order, and Channel Capacity

    Directory of Open Access Journals (Sweden)

    Xin Su

    2015-01-01

    Full Text Available There have been many studies regarding antenna polarization; however, there have been few publications on the analysis of the channel capacity for polarized antenna systems using the beamforming technique. According to Chung et al., the channel capacity is determined by the density of scatterers and the transmission power, which is obtained based on the assumption that scatterers are uniformly distributed on a 3D spherical scattering model. However, it contradicts the practical scenario, where scatterers may not be uniformly distributed under outdoor environment, and lacks the consideration of fading channel gain. In this study, we derive the channel capacity of polarized uniform linear array (PULA systems using the beamforming technique in a practical scattering environment. The results show that, for PULA systems, the channel capacity, which is boosted by beamforming diversity, can be determined using the channel gain, beam radiation pattern, and beamforming diversity order (BDO, where the BDO is dependent on the antenna characteristics and array configurations.

  16. Time-resolved electron-beam characterizations with optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H. (Argonne National Lab., IL (United States)); Wilke, M.D. (Los Alamos National Lab., NM (United States))

    1992-01-01

    Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

  17. Time-resolved electron-beam characterizations with optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H. [Argonne National Lab., IL (United States); Wilke, M.D. [Los Alamos National Lab., NM (United States)

    1992-09-01

    Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

  18. Further time-resolved electron-beam characterizations with optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H. (Argonne National Lab., IL (United States). Advanced Photon Source Accelerator Systems Div.); Wilke, M.D. (Los Alamos National Lab., NM (United States))

    1992-01-01

    Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

  19. Further time-resolved electron-beam characterizations with optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H. [Argonne National Lab., IL (United States). Advanced Photon Source Accelerator Systems Div.; Wilke, M.D. [Los Alamos National Lab., NM (United States)

    1992-12-31

    Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

  20. Monoenergetic source of kilodalton ions from Taylor cones of ionic liquids

    Science.gov (United States)

    Larriba, C.; Castro, S.; Fernandez de la Mora, J.; Lozano, P.

    2007-04-01

    The ionic liquid ion sources (ILISs) recently introduced by Lozano and Martinez Sanchez [J. Colloid Interface Sci. 282, 415 (2005)], based on electrochemically etched tungsten tips as emitters for Taylor cones of ionic liquids (ILs), have been tested with ionic liquids [A+B-] of increasing molecular weight and viscosity. These ILs have electrical conductivities well below 1S/m and were previously thought to be unsuitable to operate in the purely ionic regime because their Taylor cones produce mostly charged drops from conventional capillary tube sources. Strikingly, all the ILs tried on ILIS form charged beams composed exclusively of small ions and cluster ions A+(AB)n or B-(AB)n, with abundances generally peaking at n =1. Particularly interesting are the positive and negative ion beams produced from the room temperature molten salts 1-methyl-3-pentylimidazolium tris(pentafluoroethyl) trifluorophosphate (C5MI-(C2F5)3PF3) and 1-ethyl-3-methylimidazolium bis(pentafluoroethyl) sulfonylimide (EMI-(C2F5SO3)2N). We extend to these heavier species the previous conclusions from Lozano and Martinez Sanchez on the narrow energy distributions of the ion beams. In combination with suitable ILs, this source yields nanoamphere currents of positive and negative monoenergetic molecular ions with masses exceeding 2000amu. Potential applications are in biological secondary ion mass spectrometry, chemically assisted high-resolution ion beam etching, and electrical propulsion. Advantages of the ILISs versus similar liquid metal ion sources include the possibility to form negative as well as positive ion beams and a much wider range of ion compositions and molecular masses.

  1. Improving efficiency and safety in external beam radiation therapy treatment delivery using a Kaizen approach.

    Science.gov (United States)

    Kapur, Ajay; Adair, Nilda; O'Brien, Mildred; Naparstek, Nikoleta; Cangelosi, Thomas; Zuvic, Petrina; Joseph, Sherin; Meier, Jason; Bloom, Beatrice; Potters, Louis

    2017-06-29

    Modern external beam radiation therapy treatment delivery processes potentially increase the number of tasks to be performed by therapists and thus opportunities for errors, yet the need to treat a large number of patients daily requires a balanced allocation of time per treatment slot. The goal of this work was to streamline the underlying workflow in such time-interval constrained processes to enhance both execution efficiency and active safety surveillance using a Kaizen approach. A Kaizen project was initiated by mapping the workflow within each treatment slot for 3 Varian TrueBeam linear accelerators. More than 90 steps were identified, and average execution times for each were measured. The time-consuming steps were stratified into a 2 × 2 matrix arranged by potential workflow improvement versus the level of corrective effort required. A work plan was created to launch initiatives with high potential for workflow improvement but modest effort to implement. Time spent on safety surveillance and average durations of treatment slots were used to assess corresponding workflow improvements. Three initiatives were implemented to mitigate unnecessary therapist motion, overprocessing of data, and wait time for data transfer defects, respectively. A fourth initiative was implemented to make the division of labor by treating therapists as well as peer review more explicit. The average duration of treatment slots reduced by 6.7% in the 9 months following implementation of the initiatives (P = .001). A reduction of 21% in duration of treatment slots was observed on 1 of the machines (P Kaizen approach has the potential to improve operational efficiency and safety with quick turnaround in radiation therapy practice by addressing non-value-adding steps characteristic of individual department workflows. Higher effort opportunities are identified to guide continual downstream quality improvements. Copyright © 2017. Published by Elsevier Inc.

  2. Emission and propagation of Saturn kilometric radiation: Magnetoionic modes, beaming pattern, and polarization state

    Science.gov (United States)

    Lamy, L.; Cecconi, B.; Zarka, P.; Canu, P.; Schippers, P.; Kurth, W. S.; Mutel, R. L.; Gurnett, D. A.; Menietti, D.; Louarn, P.

    2011-04-01

    The Cassini mission crossed the source region of the Saturn kilometric radiation (SKR) on 17 October 2008. On this occasion, the Radio and Plasma Wave Science (RPWS) experiment detected both local and distant radio sources, while plasma parameters were measured in situ by the magnetometer and the Cassini Plasma Spectrometer. A goniopolarimetric inversion was applied to RPWS three-antenna electric measurements to determine the wave vector k and the complete state of polarization of detected waves. We identify broadband extraordinary (X) mode as well as narrowband ordinary (O) mode SKR at low frequencies. Within the source region, SKR is emitted just above the X mode cutoff frequency in a hot plasma, with a typical electron-to-wave energy conversion efficiency of ˜1% (2% peak). The knowledge of the k vector is then used to derive the locus of SKR sources in the kronian magnetosphere, which shows X and O components emanating from the same regions. We also compute the associated beaming angle at the source θ‧ = (k, -B) either from (1) in situ measurements or a model of the magnetic field vector (for local to distant sources) or (2) polarization measurements (for local sources). Obtained results, similar for both modes, suggest quasi-perpendicular emission for local sources, whereas the beaming pattern of distant sources appears as a hollow cone with a frequency-dependent constant aperture angle: θ‧ = 75° ± 15° below 300 kHz, decreasing at higher frequencies to reach θ‧ (1000 kHz) = 50° ± 25°. Finally, we investigate quantitatively the SKR polarization state, observed to be strongly elliptical at the source, and quasi-purely circular for sources located beyond approximately two kronian radii. We show that conditions of weak mode coupling are achieved along the raypath, under which the magnetoionic theory satisfactorily describes the evolution of the observed polarization. These results are analyzed comparatively with the auroral kilometric radiation at

  3. Radiative transport produced by oblique illumination of turbid media with collimated beams.

    Science.gov (United States)

    Gardner, Adam R; Kim, Arnold D; Venugopalan, Vasan

    2013-06-01

    We examine the general problem of light transport initiated by oblique illumination of a turbid medium with a collimated beam. This situation has direct relevance to the analysis of cloudy atmospheres, terrestrial surfaces, soft condensed matter, and biological tissues. We introduce a solution approach to the equation of radiative transfer that governs this problem, and develop a comprehensive spherical harmonics expansion method utilizing Fourier decomposition (SHEF(N)). The SHEF(N) approach enables the solution of problems lacking azimuthal symmetry and provides both the spatial and directional dependence of the radiance. We also introduce the method of sequential-order smoothing that enables the calculation of accurate solutions from the results of two sequential low-order approximations. We apply the SHEF(N) approach to determine the spatial and angular dependence of both internal and boundary radiances from strongly and weakly scattering turbid media. These solutions are validated using more costly Monte Carlo simulations and reveal important insights regarding the evolution of the radiant field generated by oblique collimated beams spanning ballistic and diffusely scattering regimes.

  4. Robust broadband beam-forming based on the feature of underwater target radiated noise

    Science.gov (United States)

    Chen, Xin-hua; Liu, Chao; Yu, Hua-bing; Zheng, En-ming; Sun, Chang-yu

    2016-12-01

    To the problem of the unknown underwater target detection, according to the feature that the underwater target radiated noise contains the stable line spectrum, a weighted method based on the main-to-side lobe ratio (MSLR) is proposed for broadband beam-forming. This weighted method can be implemented by using the following steps. Firstly, optimize the spatial spectrum of each frequency unit by the second-order cone programming (SOCP), and obtain the optimized spatial spectrum with lower side lobe. Secondly, construct weighting factors based on the MSLR of the optimized spatial spectrums to from weight factors. Lastly, cumulate the spatial spectrum of each frequency unit via the weight statistical method of this paper. This method can restrain the disturbance of background noise, enhance the output signal-to-noise ratio (SNR), and overcome the difficulty of traditional four-dimensional display. The theoretical analysis and simulation results both verify that this method can well enhance the spatial spectrum of line spectrum units, restrain the spatial spectrum of background noise units, and improve the performance of the broadband beam-forming.

  5. Improving the quality of radiographic images acquired with conical radiation beams through divergence correction and filtering

    Science.gov (United States)

    Silvani, M. I.; Almeida, G. L.; Latini, R. M.; Bellido, A. V. B.; Souza, E. S.; Lopes, R. T.

    2015-07-01

    Earlier works have shown the feasibility to correct the deformation of the attenuation map in radiographs acquired with conical radiation beams provided that the inspected object could be expressed into analytical geometry terms. This correction reduces the contribution of the main object in the radiograph, allowing thus the visualization of its otherwise concealed heterogeneities. However, the non-punctual character of the source demanded a cumbersome trial-and-error approach in order to determine the proper correction parameters for the algorithm. Within this frame, this work addresses the improvement of radiographs of specially tailored test-objects acquired with a conical beam through correction of its divergence by using the information contained in the image itself. The corrected images have afterwards undergone a filtration in the frequency domain aiming at the reduction of statistical fluctuation and noise by using a 2D Fourier transform. All radiographs have been acquired using 165Dy and 198Au gamma-ray sources produced at the Argonauta research reactor in Institutode Engenharia Nuclear - CNEN, and an X-ray sensitive imaging plate as detector. The processed images exhibit features otherwise invisible in the original ones. Their processing by conventional histogram equalization carried out for comparison purposes did not succeed to detect those features.

  6. Molecular beam mass spectrometry with tunable vacuum ultraviolet (VUV) synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Golan, Amir; Ahmed, Musahid

    2012-01-01

    Tunable soft ionization coupled to mass spectroscopy is a powerful method to investigate isolated molecules, complexes and clusters and their spectroscopy and dynamics.[1-4] Fundamental studies of photoionization processes of biomolecules provide information about electronic structure of these systems. Furthermore determinations of ionization energies and other properties of biomolecules in the gas phase are not trivial, and these experiments provide a platform to generate these data. We have developed a thermal vaporization technique coupled with supersonic molecular beams that provides a gentle way to transport these species into the gas phase. Judicious combination of source gas and temperature allows for formation of dimers and higher clusters of the DNA bases. The focus of this particular work is on the effects of non-covalent interactions, i.e., hydrogen bonding, stacking, and electrostatic interactions, on the ionization energies and proton transfer of individual biomolecules, their complexes and upon micro-hydration by water.[1, 5-9] We have performed experimental and theoretical characterization of the photoionization dynamics of gas-phase uracil and 1,3-methyluracil dimers using molecular beams coupled with synchrotron radiation at the Chemical Dynamics Beamline[10] located at the Advanced Light Source and the experimental details are visualized here. This allowed us to observe the proton transfer in 1,3-dimethyluracil dimers, a system with pi stacking geometry and with no hydrogen bonds[1]. Molecular beams provide a very convenient and efficient way to isolate the sample of interest from environmental perturbations which in return allows accurate comparison with electronic structure calculations[11, 12]. By tuning the photon energy from the synchrotron, a photoionization efficiency (PIE) curve can be plotted which informs us about the cationic electronic states. These values can then be compared to theoretical models and calculations and in turn, explain

  7. Molecular beam mass spectrometry with tunable vacuum ultraviolet (VUV) synchrotron radiation.

    Science.gov (United States)

    Golan, Amir; Ahmed, Musahid

    2012-10-30

    Tunable soft ionization coupled to mass spectroscopy is a powerful method to investigate isolated molecules, complexes and clusters and their spectroscopy and dynamics(1-4). Fundamental studies of photoionization processes of biomolecules provide information about the electronic structure of these systems. Furthermore determinations of ionization energies and other properties of biomolecules in the gas phase are not trivial, and these experiments provide a platform to generate these data. We have developed a thermal vaporization technique coupled with supersonic molecular beams that provides a gentle way to transport these species into the gas phase. Judicious combination of source gas and temperature allows for formation of dimers and higher clusters of the DNA bases. The focus of this particular work is on the effects of non-covalent interactions, i.e., hydrogen bonding, stacking, and electrostatic interactions, on the ionization energies and proton transfer of individual biomolecules, their complexes and upon micro-hydration by water(1, 5-9). We have performed experimental and theoretical characterization of the photoionization dynamics of gas-phase uracil and 1,3-dimethyluracil dimers using molecular beams coupled with synchrotron radiation at the Chemical Dynamics Beamline(10) located at the Advanced Light Source and the experimental details are visualized here. This allowed us to observe the proton transfer in 1,3-dimethyluracil dimers, a system with pi stacking geometry and with no hydrogen bonds(1). Molecular beams provide a very convenient and efficient way to isolate the sample of interest from environmental perturbations which in return allows accurate comparison with electronic structure calculations(11, 12). By tuning the photon energy from the synchrotron, a photoionization efficiency (PIE) curve can be plotted which informs us about the cationic electronic states. These values can then be compared to theoretical models and calculations and in turn

  8. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    DEFF Research Database (Denmark)

    Thing, Rune Slot; Bernchou, Uffe; Mainegra-Hing, Ernesto

    2016-01-01

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five ...

  9. ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II

    Directory of Open Access Journals (Sweden)

    Nicholas G. Zaorsky, MD

    2017-07-01

    Conclusions: External beam radiation is a key component of the curative management of T1 and T2 prostate cancer. By combining the most recent medical literature, these Appropriateness Criteria can aid clinicians in determining the appropriate treatment delivery and personalized approaches for individual patients.

  10. Calibration of the radiation monitors from DESY and SPring-8 at the quasi-mono-energetic neutron beams using 100 and 300 MeV 7Li(p,n) reaction at RCNP in Osaka Japan in November 2014

    Science.gov (United States)

    Leuschner, Albrecht; Asano, Yoshihiro; Klett, Alfred

    2017-09-01

    At the ring cyclotron facility of the Research Center for Nuclear Physics (RCNP) Osaka University, Osaka, Japan a series of measurement campaigns had been continued with quasi mono-energetic neutron beams in November 2014. A 7Li target was bombarded with 100 and 300 MeV protons and the generated neutron beams were directed into a long time-of-flight tunnel at 0 and 25 degrees deflection angle with respect to the proton beam. At a distance of 41 m the cross section of the neutron beam was large enough for the illumination of square meter sized objects like extended range rem-counters. The research institutes SPring-8/RIKEN, Japan, and DESY, Germany, participated in this campaign for the calibration of 4 different types of active ambient dose rate monitors: LB 6411, LB 6411-Pb, LB 6419 and LB 6420. The measurements of their responses are reported and compared with the calculated values.

  11. Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

    CERN Document Server

    Mei, Liu; Hui-Rong, Qi; Bao-An, Zhuang; Jian, Zhang; Rong-Guang, Liu; Qi-Ming, Zhu; Qun, Ouyang; Yuan-Bo, Chen; Xiao-Shan, Jiang; Ya-Jie, Wang; Peng, Liu; Guang-Cai, Chang

    2013-01-01

    One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 um (sigma value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of detector. The effect was analyzed and it came to a conclusion that it would be the optimal measurement scheme when the distance between the powder sample...

  12. Design strength evaluation of RC beams under radiation environments for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Won-Hee [Institute for Infrastructure Engineering, University of Western Sydney, Penrith, NSW 2751 (Australia); Kwon, Tae-Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Hyeong-Tae [Department of Civil and Environmental Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Park, Kyoungsoo, E-mail: k-park@yonsei.ac.kr [Department of Civil and Environmental Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)

    2016-05-15

    Neutron irradiation changes the behavior of construction materials such as strength and ductility, and thus structural design equations or their safety margins should accordingly be updated for the design of nuclear power plants (NPP) under irradiation. However, current design codes do not account for such changes in material strength. In this study, a framework is proposed to evaluate the change of the safety margins in design equations of reinforced concrete (RC) flexural members under radiation environments. Material strength changes are approximated on the basis of a collected test database, and the design strengths of RC beams are evaluated considering these material strength changes. The evaluation results demonstrate that the design strength of an under-reinforced flexural member can increase while the design strength of an over-reinforced member generally decreases. These results are associated with the material strength changes such that the yield strength of steel increases and the compressive strength of concrete decreases with the fluence of neutron radiation. Current NPP design codes need to further consider this un-conservative design possibility due to the design strength reduction of flexural members under irradiation.

  13. Intense ion beam generation, plasma radiation source and plasma opening switch research

    Science.gov (United States)

    Hammer, D. A.; Coleman, M. D.; Qi, N.; Similon, P. L.; Sudan, R. N.

    1989-04-01

    This report describes research on intense ion beam diodes, plasma opening switches and dense z-pinch plasma radiators. Laser induced fluorescence spectroscopy has been used to map the electrostatic potential profile in a plasma-prefilled magnetically insulated ion diode. In a simple planar diode, the measured profile is inconsistent with the electrons being confined in a sheath near the cathode by the magnetic field. Rather, the profile implies the presence of electrons throughout the accelerating gap. A theoretical model of the penetration of current and magnetic field into a plasma, and of the current-driven effective collision frequency has been developed. The snowplow action of the rising magnetic field causes a steep rise in the plasma density at the leading edge. The subsequent multistreaming of the ions caused by ion reflection at the current layer could lead to ion heating through collective effects. The two-dimensional electron flow in the plasma cathode vacuum gap is also treated. Dense z-pinch plasma radiation source experiments have been initiated on the LION accelerator using gas puff and fine wire loads. The x-pinch was found to be a more effective way to generate soft x-rays than a single wire pinch or a gas puff implosion. Plasma opening switch experiments being initiated, and plasma anode ion diode development work being terminated are also briefly described.

  14. Vacuum channeling radiation by relativistic electrons in a transverse field of a laser-based Bessel beam.

    Science.gov (United States)

    Schächter, L; Kimura, W D

    2015-05-15

    Relativistic electrons counterpropagating through the center of a radially polarized J_{1} optical Bessel beam in vacuum will emit radiation in a manner analogous to the channeling radiation that occurs when charged particles traverse through a crystal lattice. However, since this interaction occurs in vacuum, problems with scattering of the electrons by the lattice atoms are eliminated. Contrary to inverse Compton scattering, the emitted frequency is also determined by the amplitude of the laser field, rather than only by its frequency. Adjusting the value of the laser field permits the tuning of the emitted frequency over orders of magnitude, from terahertz to soft X rays. High flux intensities are predicted (~100 MW/cm^{2}). Extended interaction lengths are feasible due to the diffraction-free properties of the Bessel beam and its radial field, which confines the electron trajectory within the center of the Bessel beam.

  15. Few-view and limited-angle cone-beam megavoltage CT for breast localization in radiation therapy

    Science.gov (United States)

    Yu, Lifeng; Pan, Xiaochuan; Pelizzari, Charles A.; Martel, Mary

    2004-05-01

    In radiation therapy for breast cancer treatment, information about the external (skin) and internal (lung) boundaries is highly useful for determining the relative locations of the target and lung. In this work, we investigate the feasibility of tomographic reconstruction from few-view and limited-angle cone-beam projections acquired in radiation therapy unit for obtaining critical boundary information. From the few-view and limited-angle projections acquired directly in the treatment machine with an amorphous silicon electronic portal imaging device (EPID), We compared and evaluated the performance of the conventional cone-beam FDK algorithm and an iterative algorithm based upon the maximum-likelihood method for transmission tomography (ML-TR). Preliminary results demonstrated that the ML-TR algorithm is more promising than is the cone-beam FDK algorithm. Useful boundary information for breast localization can be obtained with very few projections in a limited angle range from the reconstruction of ML-TR algorithm.

  16. Radiation dose saving through the use of cone-beam CT in hearing-impaired patients.

    Science.gov (United States)

    Faccioli, N; Barillari, M; Guariglia, S; Zivelonghi, E; Rizzotti, A; Cerini, R; Mucelli, R Pozzi

    2009-12-01

    Bionic ear implants provide a solution for deafness. Patients treated with these hearing devices are often children who require close follow-up with frequent functional and radiological examinations; in particular, multislice computed tomography (MSCT). Dental volumetric cone-beam CT (CBCT) has been reported as a reliable technique for acquiring images of the temporal bone while delivering low radiation doses and containing costs. The aim of this study was to assess, in terms of radiation dose and image quality, the possibility of using CBCT as an alternative to MSCT in patients with bionic ear implants. One hundred patients (mean age 26 years, range 7-43) with Vibrant SoundBridge implants on the round window underwent follow-up: 85 with CBCT and 15 with MSCT. We measured the average tissue-absorbed doses during both MSCT and CBCT scans. Each scan was focused on the temporal bone with the smallest field of view and a low-dose protocol. In order to estimate image quality, we obtained data about slice thickness, high- and low-contrast resolution, uniformity and noise by using an AAPM CT performance phantom. Although the CBCT images were qualitatively inferior to those of MSCT, they were sufficiently diagnostic to allow evaluation of the position of the implants. The effective dose of MSCT was almost three times higher than that of CBCT. Owing to low radiation dose and sufficient image quality, CBCT could be considered an adequate technique for postoperative imaging and follow-up of patients with bionic ear implants.

  17. Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Mark [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Reid, Karen [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P. [Norfolk and Norwich University Hospital and University of East Anglia, Norwich (United Kingdom)

    2013-02-15

    The aim of this study was to determine whether high keV monoenergetic reconstruction of dual energy computed tomography (DECT) could be used to overcome the effects of beam hardening artefact that arise from preferential deflection of low energy photons. Two phantoms were used: a Charnley total hip replacement set in gelatine and a Catphan 500. DECT datasets were acquired at 100, 200 and 400 mA (Siemens Definition Flash, 100 and 140 kVp) and reconstructed using a standard combined algorithm (1:1) and then as monoenergetic reconstructions at 10 keV intervals from 40 to 190 keV. Semi-automated segmentation with threshold inpainting was used to obtain the attenuation values and standard deviation (SD) of the streak artefact. High contrast line pair resolution and background noise were assessed using the Catphan 500. Streak artefact is progressively reduced with increasing keV monoenergetic reconstructions. Reconstruction of a 400 mA acquisition at 150 keV results in reduction in the volume of streak artefact from 65 cm{sup 3} to 17 cm{sup 3} (74 %). There was a decrease in the contrast to noise ratio (CNR) at higher tube voltages, with the peak CNR seen at 70-80 keV. High contrast spatial resolution was maintained at high keV values. Monoenergetic reconstruction of dual energy CT at increasing theoretical kilovoltages reduces the streak artefact produced by beam hardening from orthopaedic prostheses, accompanied by a modest increase in heterogeneity of background image attenuation, and decrease in contrast to noise ratio, but no deterioration in high contrast line pair resolution. (orig.)

  18. A Monte Carlo study of monoenergetic and polyenergetic normalized glandular dose (DgN) coefficients in mammography

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Di Lillo, Francesca; Russo, Paolo

    2017-01-01

    We investigated the influence of model assumptions in GEANT4 Monte Carlo (MC) simulations for the calculation of monoenergetic and polyenergetic normalized glandular dose coefficients (DgN) in mammography, focussing on the effect of the skin thickness and composition, of the role of compression paddles and of the bremsstrahlung processes. We showed that selecting a skin thickness of 4 mm instead of 1.45 mm produced DgN values with deviations from 9% to 32% for x-ray spectra routinely adopted in mammography. Consideration of the bremsstrahlung radiation had a weak influence on monoenergetic DgN. Simulations (in the range 8-40 kVp) which included consideration of bremsstrahlung radiation, a skin thickness of 1.45 mm and a 2 mm thick compression paddles produced polyenergetic DgN coefficients up to 19% higher than corresponding literature data. Adding a 2 mm thick adipose layer between the skin layer and the radiosensitive portion of the breast produces polyenergetic DgN values up to 15% higher than those routinely adopted. These findings provide a quantitative estimate of the influence of model parameters on the calculation of the mean glandular dose in mammography.

  19. Radiation-hard Beam Position Detector for Use in the Accelerator Dump Lines

    CERN Document Server

    Degtiarenko, Pavel; Popov, Vladimir

    2005-01-01

    Proper transport of the electron beam with over 0.5MW of power to the beam dump is a prerequisite for operations at Jefferson Lab. Operations has relied on imaging the beam on a beam viewer located at the entrance to the beam dump. The large beam size at the dump entrance, due to beam scattering in the experimental target, sometimes results in no observable image on the view-screen. Chemical vapor deposited silicon carbide (CVD) material with its large thermal conductivity and high melting point is well suited for surviving the thermal effects of beam exposure with this power density. We are exploring the CVD properties and how it can be used as a robust beam position monitor. Results of some beam tests with 0.5MW beams will be presented.

  20. Radiation induced currents in parallel plate ionization chambers: measurement and Monte Carlo simulation for megavoltage photon and electron beams.

    Science.gov (United States)

    Abdel-Rahman, Wamied; Seuntjens, Jan P; Verhaegen, Frank; Podgorsak, Ervin B

    2006-09-01

    Polarity effects in ionization chambers are caused by a radiation induced current, also known as Compton current, which arises as a charge imbalance due to charge deposition in electrodes of ionization chambers. We used a phantom-embedded extrapolation chamber (PEEC) for measurements of Compton current in megavoltage photon and electron beams. Electron contamination of photon beams and photon contamination of electron beams have a negligible effect on the measured Compton current. To allow for a theoretical understanding of the Compton current produced in the PEEC effect we carried out Monte Carlo calculations with a modified user code, the COMPTON/ EGSnrc. The Monte Carlo calculated COMPTON currents agree well with measured data for both photon and electron beams; the calculated polarity correction factors, on the other hand, do not agree with measurement results. The conclusions reached for the PEEC can be extended to parallel-plate ionization chambers in general.

  1. High energy beam impact tests on a LHC tertiary collimator at the CERN high-radiation to materials facility

    Directory of Open Access Journals (Sweden)

    Marija Cauchi

    2014-02-01

    Full Text Available The correct functioning of a collimation system is crucial to safely operate highly energetic particle accelerators, such as the Large Hadron Collider (LHC. The requirements to handle high intensity beams can be demanding. In this respect, investigating the consequences of LHC particle beams hitting tertiary collimators (TCTs in the experimental regions is a fundamental issue for machine protection. An experimental test was designed to investigate the robustness and effects of beam accidents on a fully assembled collimator, based on accident scenarios in the LHC. This experiment, carried out at the CERN High-Radiation to Materials (HiRadMat facility, involved 440 GeV proton beam impacts of different intensities on the jaws of a horizontal TCT. This paper presents the experimental setup and the preliminary results obtained, together with some first outcomes from visual inspection and a comparison of such results with numerical simulations.

  2. Development of the microstrip silicon detector for imaging of fast processes at a synchrotron radiation beam

    Science.gov (United States)

    Aulchenko, V.; Pruuel, E.; Shekhtman, L.; Ten, K.; Tolochko, B.; Zhulanov, V.

    2017-02-01

    In situ imaging of explosions allows to study material properties under very high pressures and temperatures. Synchrotron radiation (SR) is a powerful tool for such studies because of its unique time structure. Flashes of X-rays from individual bunches in a storage ring are so short that an object under study does not move more than 1-10 μm during exposure. If a detector is able to store images synchronously with bunches of an SR source the time resolution of such method will be determined by the duration of SR flash from individual bunch. New beam line at the VEPP-4M storage ring will allow to get X-Ray flux from each bunch close to 106 photons/channel where channel area is 0.05×0.5 mm2 and average beam energy is about 30 keV. Bunches in the machine can be grouped into trains with 20 ns time gap. In order to meet these requirements a new detector development was started based on Si microstrip technology. The detector with a new dedicated front-end chip will be able to record images with maximum signal equivalent to 106 photons/channel, with signal to noise ratio of ∼103, spatial resolution of 50 μm and maximum frame rate of 50 MHz. The detector has to drive very high peak and average currents without affecting the front-end chip, therefore a specific design of Si sensor should be developed. The front-end chip has to provide signal measurements with the dynamic range of about 104 or more and recording of the signal to an analogue memory with the rate of 50 MHz. The concept of such detector is discussed in the paper. The results of the simulations of the main detector parameters and the results of the first measurements with the prototype sensors are presented.

  3. Contribution to the beam plasma material interactions during material processing with TEA CO2 laser radiation

    Science.gov (United States)

    Jaschek, Rainer; Konrad, Peter E.; Mayerhofer, Roland; Bergmann, Hans W.; Bickel, Peter G.; Kowalewicz, Roland; Kuttenberger, Alfred; Christiansen, Jens

    1995-03-01

    The TEA-CO2-laser (transversely excited atmospheric pressure) is a tool for the pulsed processing of materials with peak power densities up to 1010 W/cm2 and a FWHM of 70 ns. The interaction between the laser beam, the surface of the work piece and the surrounding atmosphere as well as gas pressure and the formation of an induced plasma influences the response of the target. It was found that depending on the power density and the atmosphere the response can take two forms. (1) No target modification due to optical break through of the atmosphere and therefore shielding of the target (air pressure above 10 mbar, depending on the material). (2) Processing of materials (air pressure below 10 mbar, depending on the material) with melting of metallic surfaces (power density above 0.5 109 W/cm2), hole formation (power density of 5 109 W/cm2) and shock hardening (power density of 3.5 1010 W/cm2). All those phenomena are usually linked with the occurrence of laser supported combustion waves and laser supported detonation waves, respectively for which the mechanism is still not completely understood. The present paper shows how short time photography and spatial and temporal resolved spectroscopy can be used to better understand the various processes that occur during laser beam interaction. The spectra of titanium and aluminum are observed and correlated with the modification of the target. If the power density is high enough and the gas pressure above a material and gas composition specific threshold, the plasma radiation shows only spectral lines of the background atmosphere. If the gas pressure is below this threshold, a modification of the target surface (melting, evaporation and solid state transformation) with TEA-CO2- laser pulses is possible and the material specific spectra is observed. In some cases spatial and temporal resolved spectroscopy of a plasma allows the calculation of electron temperatures by comparison of two spectral lines.

  4. Monte Carlo calculations of monoenergetic electron depth dose distributions in LiF chips: Skin dose correction factors for beta rays

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Y.S. [Ben Gurion Univ. of the Negev, Beersheva (Israel); Hirning, C.R. [Ontario Hydro, Whitby (Canada); Yuen, P.; Wong, P. [Chalk River Labs., Ontario (Canada)

    1994-10-01

    Monte Carlo calculations have been carried out for monoenergetic electrons from 0.1 to 4 MeV irradiating LiF chips in both perpendicular and isotropic geometry. This enabled the calculation of skin dose correction factors (beta factors) for typical beta energy spectra as measured with a beta-ray spectrometer at CANDU nuclear generating stations. The correction factors were estimated by averaging the depth dose distributions for the monoenergetic electrons over the experimentally measured beta-ray spectra. The calculations illustrate the large uncertainty in beta factors arising from the unknown angular distribution of the beta-ray radiation field and uncertainties in the shape of the beta-ray spectra below 500 keV. 28 refs., 8 figs., 2 tabs.

  5. [The role of external beam radiation therapy in the adjuvant treatment of pigmented villonodular synovitis].

    Science.gov (United States)

    Heyd, R; Seegenschmiedt, M H; Micke, O

    2011-12-01

    Pigmented villonodular synovitis (PVNS) is a rare proliferative disorder arising from synovial cells of the tendon sheets and joint capsules. The potential value of external beam radiation therapy in the interdisciplinary management of PVNS is demonstrated by a comprehensive literature review on the clinical use of radiotherapy and the results of national patterns of care study (PCS) which was conducted by the German Cooperative Group on Radiotherapy in Benign Diseases (GCG-BD) in 2008-2009. A structured questionnaire was mailed to all 227 RT institutions in Germany to assess all previous treatments, the RT indication and techniques, the rate of local control, the functional outcome and the possible adverse effects related to the use of external beam radiation therapy (RT). For comparison of the clinical outcome data, a systematic literature research in several international electronic databases and a conventional library search were performed to identify publications addressing the use of RT for PVNS. Based on an overall response rate of 83.2%, the PCS was nationally representative. Ten percent of institutions presented clinical experience with the use of RT for PVNS; from this database a total of 41 treated sites from 14 institutions were evaluable for long-term analysis. The primary therapeutic approach was cytoreductive surgery in all cases. In cases of residual tissue or complete resection of extensive local recurrences, RT was applied in 39 cases (95.1%). An excellent or good functional outcome was noted in 34 cases (82.9%). The use of RT was not associated with early or late toxicity larger than RTOG grade II. The literature review identified 19 published studies (1940-2009) which represented a total of 140 cases or patients, respectively. After follow-up periods ranging from 1-250 months and administration of total doses in the range of 16-50 Gy the overall rate of local control was 84.5%. Both the results of the national PCS and the literature review

  6. Intensity Modulated Proton Beam Radiation for Brachytherapy in Patients With Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Clivio, Alessandro [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Kluge, Anne [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany); Cozzi, Luca, E-mail: lucozzi@iosi.ch [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Köhler, Christhardt [Department of Gynecology, Charité University Hospital, Berlin (Germany); Neumann, Oliver [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany); Vanetti, Eugenio [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Wlodarczyk, Waldemar; Marnitz, Simone [Department of Radiation Oncology, Charité University Hospital, Berlin (Germany)

    2013-12-01

    Purpose: To evaluate intensity modulated proton therapy (IMPT) in patients with cervical cancer in terms of coverage, conformity, and dose–volume histogram (DVH) parameters correlated with recommendations from magnetic resonance imaging (MRI)-guided brachytherapy. Methods and Materials: Eleven patients with histologically proven cervical cancer underwent primary chemoradiation for the pelvic lymph nodes, the uterus, the cervix, and the parametric region, with a symmetric margin of 1 cm. The prescription was for 50.4 Gy, with 1.8 Gy per fraction. The prescribed dose to the parametria was 2.12 Gy up to 59.36 Gy in 28 fractions as a simultaneous boost. For several reasons, the patients were unable to undergo brachytherapy. As an alternative, IMPT was planned with 5 fractions of 6 Gy to the cervix, including the macroscopic tumor with an MRI-guided target definition, with an isotropic margin of 5 mm for planning target volume (PTV) definition. Groupe-Europeen de Curietherapie and European society for Radiotherapy and Oncology (GEC-ESTRO) criteria were used for DVH evaluation. Reference comparison plans were optimized for volumetric modulated rapid arc (VMAT) therapy with the RapidArc (RA). Results: The dose to the high-risk volume was calculated with α/β = 10 with 89.6 Gy. For IMPT, the clinical target volume showed a mean dose of 38.2 ± 5.0 Gy (35.0 ±1.8 Gy for RA). The D{sub 98%} was 31.9 ± 2.6 Gy (RA: 30.8 ± 1.0 Gy). With regard to the organs at risk, the 2Gy Equivalent Dose (EQD2) (α/β = 3) to 2 cm{sup 3} of the rectal wall, sigmoid wall, and bladder wall was 62.2 ± 6.4 Gy, 57.8 ± 6.1 Gy, and 80.6 ± 8.7 Gy (for RA: 75.3 ± 6.1 Gy, 66.9 ± 6.9 Gy, and 89.0 ± 7.2 Gy, respectively). For the IMPT boost plans in combination with external beam radiation therapy, all DVH parameters correlated with <5% risk for grades 2 to 4 late gastrointestinal and genitourinary toxicity. Conclusion: In patients who are not eligible for brachytherapy, IMPT as a boost

  7. Study of the measurement of critical parameters in an electron beam radiation facility. Application to the case of the first accelerator dedicated to radiation in Tunisia

    Energy Technology Data Exchange (ETDEWEB)

    M' Garrech, S. [Laboratoire de Radio-traitement, Centre National des Sciences et Technologies Nucleaires, 2020 Sidi-Thabet (Tunisia)], E-mail: mgslah@yahoo.fr; Ezzouch, A. [Institut National des Sciences Appliquees et de Technologie, 1080 Tunis (Tunisia)

    2009-02-15

    The Tunisian National Center for Nuclear Sciences and Technologies will acquire the first North African Radio Frequency linear accelerator of electrons in 2009. The facility will be designed primarily for sterilization of medical devices and preservation of foodstuff. The first part of this paper is dedicated to a description of the facility. In order to adjust the treatment conditions and to control the good operation of the accelerator, it is necessary to find out several electron beam parameters. The second part of the paper is devoted to the presentation of the system dedicated to determining several key parameters of the electron beam. The performances and advantages of the diagnostic system cited in this report make it quite suitable for process control application at an electron beam radiation processing facility.

  8. High-Brightness High-Energy Electron Beams from a Laser Wakefield Accelerator via Energy Chirp Control

    Science.gov (United States)

    Wang, W. T.; Li, W. T.; Liu, J. S.; Zhang, Z. J.; Qi, R.; Yu, C. H.; Liu, J. Q.; Fang, M.; Qin, Z. Y.; Wang, C.; Xu, Y.; Wu, F. X.; Leng, Y. X.; Li, R. X.; Xu, Z. Z.

    2016-09-01

    By designing a structured gas density profile between the dual-stage gas jets to manipulate electron seeding and energy chirp reversal for compressing the energy spread, we have experimentally produced high-brightness high-energy electron beams from a cascaded laser wakefield accelerator with peak energies in the range of 200-600 MeV, 0.4%-1.2% rms energy spread, 10-80 pC charge, and ˜0.2 mrad rms divergence. The maximum six-dimensional brightness B6 D ,n is estimated as ˜6.5 ×1 015 A /m2/0.1 % , which is very close to the typical brightness of e beams from state-of-the-art linac drivers. These high-brightness high-energy e beams may lead to the realization of compact monoenergetic gamma-ray and intense coherent x-ray radiation sources.

  9. Single-shot radiography using X-rays from Compton-backscattering with laser-wakefield accelerated electron beams

    CERN Document Server

    Döpp, A; Thaury, C; Gautier, J; Andriyash, I; Lifschitz, A; Goddet, J-P; Tafzi, A; Malka, V; Rousse, A; Phuoc, K Ta

    2015-01-01

    We present results from the production of high energy femtosecond X-rays by Compton-backscattering of an intense femtosecond laser pulse with quasi-monoenergetic laser-accelerated electron beams using a plasma mirror. In our parameter regime electrons of $\\sim$ 150 MeV peak energy emit a high energy radiation beam with a broad spectrum extending up to $\\sim$ 500 keV. The photon yield from the source is sufficiently high to illuminate a centimeter-size sample placed 90 centimeters behind the source and record a single-shot radiograph. The small diameter of the laser-accelerated electron beams translates into a micrometer X-ray source size, making it a promising candidate for advanced X-ray imaging techniques as e.g. propagation-based phase contrast imaging.

  10. Beam-excited whistler waves at oblique propagation with relation to STEREO radiation belt observations

    Directory of Open Access Journals (Sweden)

    K. Sauer

    2010-06-01

    Full Text Available Isotropic electron beams are considered to explain the excitation of whistler waves which have been observed by the STEREO satellite in the Earth's radiation belt. Aside from their large amplitudes (~240 mV/m, another main signature is the strongly inclined propagation direction relative to the ambient magnetic field. Electron temperature anisotropy with Te⊥>Te||, which preferentially generates parallel propagating whistler waves, can be excluded as a free energy source. The instability arises due to the interaction of the Doppler-shifted cyclotron mode ω=−Ωe+kVbcosθ with the whistler mode in the wave number range of kce≤1 (θ is the propagation angle with respect to the background magnetic field direction, ωe is the electron plasma frequency and Ωe the electron cyclotron frequency. Fluid and kinetic dispersion analysis have been used to calculate the growth rate of the beam-excited whistlers including the most important parameter dependencies. One is the beam velocity (Vb which, for instability, has to be larger than about 2VAe, where VAe is the electron Alfvén speed. With increasing VAe the propagation angle (θ of the fastest growing whistler waves shifts from θ~20° for Vb=2VAe to θ~80° for Vb=5VAe. The growth rate is reduced by finite electron temperatures and disappears if the electron plasma beta (βe exceeds βe~0.2. In addition, Gendrin modes (kce≈1 are analyzed to determine the conditions under which stationary nonlinear waves (whistler oscillitons can exist. The corresponding spatial wave profiles are calculated using the full nonlinear fluid approach. The results are compared with the STEREO satellite observations.

  11. Points to be noted in using radiation treatment planning system; External photon beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Irifune, Toraji (Tokyo Metropolitan Coll. of Allied Medical Sciences (Japan))

    1993-09-01

    The accuracy of absorbed dose calculations for external photon beam therapy depends on the computational algorithms being used: the acquisition of basic beam data, the patient's anatomical information, the spacing of the points in the matrices, the interpolation routine, inhomogeneity corrections, etc. At present, the dose calculation algorithms employed in most commercially available treatment planning systems for absorbed dose calculation are two-dimensional methods for photon fluence and do not take electronic equilibrium into account. Therefore, their use for radiation treatment planning is limited. In particular, the problem of inhomogeneity correction for lung is the most significant. The inhomogeneity correction methods most commonly used are ratio of TAR (RTAR), power law TAR (PTAR) and equivalent TAR (ETAR) methods. One Japanese society for therapeutic radiology and oncology (JASTRO) task group has compared the three correction methods mentioned above with measured values using the same JARP level dosimeter and lung model phantom. The photon energies were [sup 60]Co [gamma] rays, 4, 6, 10 and 18 MV x rays, and field sizes were 5 x 5, 10 x 10 and 20 x 20 cm[sup 2] at SSD 100 cm. RTAR lead to errors (%) of 2.5 to 12.6, 1.7 to 10.9, 2.7 to 8.5, 3.1 to 9.9, and 1.0 to 19.1; PTAR errors were -0.7 to 2.3, -2.1 to 1.6, -1.1 to 2.2, -0.3 to 3.9, and -2.0 to 6.6; and ETAR errors were 0.7 to 2.5, 0 to 3.1, -0.1 to 6.8, 3.4 to 9.2, and 1.0 to 18.6 for [sup 60]Co [gamma] rays, 4, 6, 10 and 18 MV x rays, respectively. Survey results showed that about 50% of the institutions used measured data obtained by themselves. Basic beam data acquisition should be self-contained. (author).

  12. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding.

    Science.gov (United States)

    Yadav, Poonam; Kozak, Kevin; Tolakanahalli, Ranjini; Ramasubramanian, V; Paliwal, Bhudatt R; Welsh, James S; Rong, Yi

    2012-01-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each "planning scan" to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields. Published by Elsevier Inc.

  13. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Kozak, Kevin [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Tolakanahalli, Ranjini [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Ramasubramanian, V. [School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Paliwal, Bhudatt R. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States); Welsh, James S. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Rong, Yi, E-mail: rong@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States)

    2012-07-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each 'planning scan' to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

  14. Measuring radiation damage dynamics by pulsed ion beam irradiation. 2015 Annual Progress Report for DOE/NE/NEET

    Energy Technology Data Exchange (ETDEWEB)

    Kucheyev, S. O. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-07

    The major goal of this project is to develop and demonstrate a novel experimental approach to access the dynamic regime of radiation damage formation processes in nuclear materials. In particular, the project exploits a pulsed-ion-beam method in order to gain insight into defect interaction dynamics by measuring effective defect interaction time constants and defect diffusion lengths. For Year 2, this project had the following two major milestones: (i) measurement of the temperature dependence of defect dynamics in SiC and (ii) the evaluation of the robustness of the pulsed beam method from studies of the defect generation rate. As we describe below, both of these milestones have been met.

  15. Self-consistent simulation of radiation and space-charge in high-brightness relativistic electron beams

    Science.gov (United States)

    Gillingham, David R.

    2007-12-01

    The ability to preserve the quality of relativistic electron beams through transport bend elements such as a bunch compressor chicane is increasingly difficult as the current increases because of effects such as coherent synchrotron radiation (CSR) and space-charge. Theoretical CSR models and simulations, in their current state, often make unrealistic assumptions about the beam dynamics and/or structures. Therefore, we have developed a model and simulation that contains as many of these elements as possible for the purpose of making high-fidelity end-to-end simulations. Specifically, we are able to model, in a completely self-consistent, three-dimensional manner, the sustained interaction of radiation and space-charge from a relativistic electron beam in a toroidal waveguide with rectangular cross-section. We have accomplished this by combining a time-domain field solver that integrates a paraxial wave equation valid in a waveguide when the dimensions are small compared to the bending radius with a particle-in-cell dynamics code. The result is shown to agree with theory under a set of constraints, namely thin rigid beams, showing the stimulation resonant modes and including comparisons for waveguides approximating vacuum, and parallel plate shielding. Using a rigid beam, we also develop a scaling for the effect of beam width, comparing both our simulation and numerical integration of the retarded potentials. We further demonstrate the simulation calculates the correct longitudinal space-charge forces to produce the appropriate potential depression for a converging beam in a straight waveguide with constant dimensions. We then run fully three-dimensional, self-consistent end-to-end simulations of two types of bunch compressor designs, illustrating some of the basic scaling properties and perform a detailed analysis of the output phase-space distribution. Lastly, we show the unique ability of our simulation to model the evolution of charge/energy perturbations on a

  16. Monte Carlo modeling in CT-based geometries: dosimetry for biological modeling experiments with particle beam radiation.

    Science.gov (United States)

    Diffenderfer, Eric S; Dolney, Derek; Schaettler, Maximilian; Sanzari, Jenine K; McDonough, James; Cengel, Keith A

    2014-03-01

    The space radiation environment imposes increased dangers of exposure to ionizing radiation, particularly during a solar particle event (SPE). These events consist primarily of low energy protons that produce a highly inhomogeneous dose distribution. Due to this inherent dose heterogeneity, experiments designed to investigate the radiobiological effects of SPE radiation present difficulties in evaluating and interpreting dose to sensitive organs. To address this challenge, we used the Geant4 Monte Carlo simulation framework to develop dosimetry software that uses computed tomography (CT) images and provides radiation transport simulations incorporating all relevant physical interaction processes. We found that this simulation accurately predicts measured data in phantoms and can be applied to model dose in radiobiological experiments with animal models exposed to charged particle (electron and proton) beams. This study clearly demonstrates the value of Monte Carlo radiation transport methods for two critically interrelated uses: (i) determining the overall dose distribution and dose levels to specific organ systems for animal experiments with SPE-like radiation, and (ii) interpreting the effect of random and systematic variations in experimental variables (e.g. animal movement during long exposures) on the dose distributions and consequent biological effects from SPE-like radiation exposure. The software developed and validated in this study represents a critically important new tool that allows integration of computational and biological modeling for evaluating the biological outcomes of exposures to inhomogeneous SPE-like radiation dose distributions, and has potential applications for other environmental and therapeutic exposure simulations.

  17. Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI

    DEFF Research Database (Denmark)

    Lynggaard Riis, Hans; Moltke, Lars N; Zimmermann, S. J.

    2016-01-01

    prior to treatment. Linac manufacturers offer tools for MV radiation isocentre localization. As a user, there is no access to the documentation for the underlying method and calculation algorithm used in the commercial software. The idea of this work was to evaluate the accuracy of the software tool......Accurate determination of the megavoltage (MV) radiation isocentre of a linear accelerator (linac) is an important task in radiotherapy. The localization of the MV radiation isocentre is crucial for correct calibration of the in-room lasers and the cone-beam CT scanner used for patient positioning...... for MV radiation isocentre calculation as delivered by Elekta using independent software. The image acquisition was based on the scheme designed by the manufacturer. Eight MV images were acquired in each series of a ball-bearing (BB) phantom attached to the treatment couch. The images were recorded...

  18. Beam stabilization in the two-dimensional nonlinear Schrödinger equation with an attractive potential by beam splitting and radiation.

    Science.gov (United States)

    leMesurier, Brenton John; Christiansen, Peter Leth; Gaididei, Yuri B; Rasmussen, Jens Juul

    2004-10-01

    The effect of attractive linear potentials on self-focusing in-waves modeled by a nonlinear Schrödinger equation is considered. It is shown that the attractive potential can prevent both singular collapse and dispersion that are generic in the cubic Schrödinger equation in the critical dimension 2 and can lead to a stable oscillating beam. This is observed to involve a splitting of the beam into an inner part that is oscillatory and of subcritical power and an outer dispersing part. An analysis is given in terms of the rate competition between the linear and nonlinear focusing effects, radiation losses, and known stable periodic behavior of certain solutions in the presence of attractive potentials.

  19. Three-dimensional Čerenkov tomography of energy deposition from ionizing radiation beams.

    Science.gov (United States)

    Glaser, Adam K; Voigt, William H A; Davis, Scott C; Zhang, Rongxiao; Gladstone, David J; Pogue, Brian W

    2013-03-01

    Since its discovery during the 1930s the Čerenkov effect (light emission from charged particles traveling faster than the local speed of light in a dielectric medium) has been paramount in the development of high-energy physics research. The ability of the emitted light to describe a charged particle's trajectory, energy, velocity, and mass has allowed scientists to study subatomic particles, detect neutrinos, and explore the properties of interstellar matter. However, to our knowledge, all applications of the process to date have focused on the identification of particles themselves, rather than their effect upon the surroundings through which they travel. Here we explore a novel application of the Čerenkov effect for the recovery of the spatial distribution of ionizing radiation energy deposition in a medium and apply it to the issue of dose determination in medical physics. By capturing multiple projection images of the Čerenkov light induced by a medical linear accelerator x-ray photon beam, we demonstrate the successful three-dimensional tomographic reconstruction of the imparted dose distribution.

  20. Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation

    Science.gov (United States)

    Zhang, Yu-Lian; Qi, Hui-Rong; Hu, Bi-Tao; Fan, Sheng-Nan; Wang, Bo; Liu, Mei; Zhang, Jian; Liu, Rong-Guang; Chang, Guang-Cai; Liu, Peng; Ouyang, Qun; Chen, Yuan-Bo; Yi, Fu-Ting

    2014-04-01

    To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the GEM preamplification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.

  1. Wettability modification of human tooth surface by water and UV and electron-beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tiznado-Orozco, Gaby E., E-mail: gab0409@gmail.com [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France); Unidad Académica de Odontología, Universidad Autónoma de Nayarit, Edificio E7, Ciudad de la Cultura “Amado Nervo”, C.P. 63190 Tepic, Nayarit (Mexico); Reyes-Gasga, José, E-mail: jreyes@fisica.unam.mx [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France); Instituto de Física, UNAM, Circuito de la Investigación s/n, Ciudad Universitaria, 04510 Coyoacan, México, D.F. (Mexico); Elefterie, Florina, E-mail: elefterie_florina@yahoo.com [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France); Beyens, Christophe, E-mail: christophe.beyens@ed.univ-lille1.fr [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France); Maschke, Ulrich, E-mail: Ulrich.Maschke@univ-lille1.fr [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France); Brès, Etienne F., E-mail: etienne.bres@univ-lille1.fr [UMET, Bâtiment C6, Université de Lille 1, Sciences et Technologies, 59650 Villeneuve d' Ascq (France)

    2015-12-01

    The wettability of the human tooth enamel and dentin was analyzed by measuring the contact angles of a drop of distilled water deposited on the surface. The samples were cut along the transverse and longitudinal directions, and their surfaces were subjected to metallographic mirror-finish polishing. Some samples were also acid etched until their microstructure became exposed. Wettability measurements of the samples were done in dry and wet conditions and after ultraviolet (UV) and electron beam (EB) irradiations. The results indicate that water by itself was able to increase the hydrophobicity of these materials. The UV irradiation momentarily reduced the contact angle values, but they recovered after a short time. EB irradiation raised the contact angle and maintained it for a long time. Both enamel and dentin surfaces showed a wide range of contact angles, from approximately 10° (hydrophilic) to 90° (hydrophobic), although the contact angle showed more variability on enamel than on dentin surfaces. Whether the sample's surface had been polished or etched did not influence the contact angle value in wet conditions. - Highlights: • Human tooth surface wettability changes in dry/wet and UV/EB radiation conditions. • More variability in contact angle is observed on enamel than on dentin surfaces. • Water by itself increases the hydrophobicity of the human tooth surface. • UV irradiation reduces momentarily the human tooth surface hydrophobicity. • EB irradiation increases and maintains the hydrophobicity for a long time.

  2. The geometric calibration of cone-beam imaging and delivery systems in radiation therapy

    CERN Document Server

    Matsinos, E; Kaissl, Wolfgang; Matsinos, Evangelos

    2006-01-01

    We propose a method to achieve the geometric calibration of cone-beam imaging and delivery systems in radiation therapy; our approach applies to devices where an X-ray source and a flat-panel detector, facing each other, move in circular orbits around the irradiated object. In order to extract the parameters of the geometry from the data, we use a light needle phantom which is easy to manufacture. A model with ten free parameters (spatial lengths and distortion angles) has been put forth to describe the geometry and the mechanical imperfections of the units being calibrated; a few additional parameters are introduced to account for residual effects (small effects which lie beyond our model). The values of the model parameters are determined from one complete scan of the needle phantom via a robust optimisation scheme. The application of this method to two sets of five counterclockwise (ccw) and five clockwise (cw) scans yielded consistent and reproducible results. A number of differences have been observed be...

  3. Applications of pixellated GaAs X-ray detectors in a synchrotron radiation beam

    CERN Document Server

    Watt, J; Campbell, M; Mathieson, K; Mikulec, B; O'Shea, V; Passmore, M S; Schwarz, C; Smith, K M; Whitehill, C

    2001-01-01

    Hybrid semiconductor pixel detectors are being investigated as imaging devices for radiography and synchrotron radiation beam applications. Based on previous work in the CERN RD19 and the UK IMPACT collaborations, a photon counting GaAs pixel detector (PCD) has been used in an X-ray powder diffraction experiment. The device consists of a 200 mu m thick SI-LEC GaAs detector patterned in a 64*64 array of 170 mu m pitch square pixels, bump-bonded to readout electronics operating in single photon counting mode. Intensity peaks in the powder diffraction pattern of KNbO/sub 3/ have been resolved and compared with results using the standard scintillator, and a PCD predecessor (the Omega 3). The PCD shows improved speed, dynamic range, 2-D information and comparable spatial resolution to the standard scintillator based systems. It also overcomes the severe dead time limitations of the Omega 3 by using a shutter based acquisition mode. A brief demonstration of the possibilities of the system for dental radiography and...

  4. Applications of pixellated GaAs X-ray detectors in a synchrotron radiation beam

    Energy Technology Data Exchange (ETDEWEB)

    Watt, J. E-mail: j.watt@physics.gla.ac.uk; Bates, R.; Campbell, M.; Mathieson, K.; Mikulec, B.; O' Shea, V.; Passmore, M-S.; Schwarz, C.; Smith, K.M.; Whitehill, C

    2001-03-11

    Hybrid semiconductor pixel detectors are being investigated as imaging devices for radiography and synchrotron radiation beam applications. Based on previous work in the CERN RD19 and the UK IMPACT collaborations, a photon counting GaAs pixel detector (PCD) has been used in an X-ray powder diffraction experiment. The device consists of a 200 {mu}m thick SI-LEC GaAs detector patterned in a 64x64 array of 170 {mu}m pitch square pixels, bump-bonded to readout electronics operating in single photon counting mode. Intensity peaks in the powder diffraction pattern of KNbO{sub 3} have been resolved and compared with results using the standard scintillator, and a PCD predecessor (the {omega}3). The PCD shows improved speed, dynamic range, 2-D information and comparable spatial resolution to the standard scintillator based systems. It also overcomes the severe dead time limitations of the {omega}3 by using a shutter based acquisition mode. A brief demonstration of the possibilities of the system for dental radiography and image processing are given, showing a marked reduction in patient dose and dead time compared with film.

  5. Degradation of catechol by ionizing radiation, ozone and the combined process ozone-electron-beam

    Energy Technology Data Exchange (ETDEWEB)

    Kubesch, K. E-mail: sonja.solar@univie.ac.at; Zona, R.; Solar, S.; Gehringer, P

    2005-03-01

    The influence of oxygen on the radiation-induced degradation of catechol (5x10{sup -4} mol dm{sup -3}, 55 mg dm{sup -3}) in distilled water was studied by gamma-radiolysis in the presence of air (A) and using air saturation (AS) during irradiation. Under AS conditions a complete decomposition of catechol as well as of the trihydroxybenzene products was obtained by a dose of 6 kGy, without air saturation all phenolic compounds were still present at 10 kGy. Using AS, at 12 kGy the total organic carbon (TOC) was reduced by 63%, without air saturation by 17.5%. Detoxification was only obtained in AS solutions. In the presence of the natural matrix of the local tap water no trihydroxybenzene products were formed and for total decomposition of catechol in AS solutions 9 kGy were required. The comparison of the effectiveness of an electron beam (EB), an ozone (O{sub 3}) and a combined EB/O{sub 3} process showed, that by EB/O{sub 3} the extent of catechol degradation corresponded to the sum of the decay with EB and with ozone, whereas for the chemical oxygen demand and TOC reduction a synergistic effect was evident.

  6. Emission and propagation of Saturn kilometric radiation: magneto-ionic modes, beaming pattern and polarization state

    CERN Document Server

    Lamy, L; Zarka, P; Canu, P; Schippers, P; Kurth, W S; Mutel, R L; Gurnett, D A; Menietti, J D; Louarn, P

    2011-01-01

    The Cassini mission crossed the source region of the Saturn kilometric radiation (SKR) on 17 October 2008. On this occasion, the Radio and Plasma Wave Science (RPWS) experiment detected both local and distant radio sources, while plasma parameters were measured in situ by the magnetometer (MAG) and the Cassini Plasma Spectrometer (CAPS). A goniopolarimetric inversion was applied to RPWS 3-antenna electric measurements to determine the wave vector k and the complete state of polarization of detected waves. We identify broadband extraordinary (X) as well as narrowband ordinary (O) mode SKR at low frequencies. Within the source region, SKR is emitted just above the X mode cutoff frequency in a hot plasma, with a typical electron-to-wave energy conversion efficiency of 1% (2% peak). The knowledge of the k-vector is then used to derive the locus of SKR sources in the kronian magnetosphere, that shows X and O components emanating from the same regions. We also compute the associated beaming angle at the source thet...

  7. The role of adjuvant external beam radiation therapy for papillary thyroid carcinoma invading the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk; Choi, Jae Hyuck; Kim, Kwang Sik [Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of); and others

    2017-06-15

    To evaluate the effect of adjuvant external beam radiation therapy (EBRT) on local failure-free survival rate (LFFS) for papillary thyroid cancer (PTC) invading the trachea. Fifty-six patients with locally advanced PTC invading the trachea were treated with surgical resection. After surgery, 21 patients received adjuvant EBRT and radioactive iodine therapy (EBRT group) and 35 patients were treated with radioactive iodine therapy (control group). The age range was 26–87 years (median, 56 years). The median follow-up period was 43 months (range, 4 to 145 months). EBRT doses ranged from 50.4 to 66 Gy (median, 60 Gy). Esophagus invasion and gross residual disease was more frequent in the EBRT group. In the control group, local recurrence developed in 9 (9/35, 26%) and new distant metastasis in 2 (2/35, 6%) patients, occurring 4 to 68 months (median, 37 months) and 53 to 68 months (median, 60 months) after surgery, respectively. Two patients had simultaneous local recurrence and new distant metastasis. There was one local failure in the EBRT group at 18 months after surgery (1/21, 5%). The 5-year LFFS was 95% in the EBRT group and 63% in the control group (p = 0.103). In the EBRT group, one late grade 2 xerostomia was developed. Although, EBRT group had a higher incidence of esophagus invasion and gross residual disease, EBRT group showed a better 5-year LFFS. Adjuvant EBRT may have contributed to the better LFFS in these patients.

  8. SU-E-T-358: Empirical Beam Angle Optimization for Lung Cancer Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Doozan, B [Florida Atlantic University (United States); Pella, S [South Florida Radiation Oncology, Boca Raton, FL (United States)

    2015-06-15

    Purpose: Creating an improved BAO can decrease the amount of time a dosimetrist spends on making a treatment plan, improve the treatment quality and enhance the tools an inexperienced dosimetrist can use to develop planning techniques. Methods: Using empirical data created by experienced dosimetrists from 69 patients treated for lung cancer, the most frequently used gantry angles were applied to four different regions in each lung to gather an optimal set of fields that could be used to treat future lung cancer patients. This method, given the moniker FAU BAO, is compared in 7 plans created with the Eclipse BAO choosing 5 fields and 9 fields. Results: The results show that the conformality index improved by 30% or 3% when using the 5 and 9 fields. The conformation number was better by 12% from the 5 fields and 9% from the 9 fields. The organs at risk (OAR) were overall more protected to produce fewer nonstochastic effects from the radiation treatment with the FAU BAO. Conclusion: Empirical methods for beam angle optimization is a viable method for IMRT treatment planning techniques.

  9. Study of nuclear recoils in liquid argon with monoenergetic neutrons

    CERN Document Server

    Regenfus, C; Amsler, C; Creus, W; Ferella, A; Rochet, J; Walter, M

    2012-01-01

    For the development of liquid argon dark matter detectors we assembled a setup in the laboratory to scatter neutrons on a small liquid argon target. The neutrons are produced mono-energetically (E_kin=2.45 MeV) by nuclear fusion in a deuterium plasma and are collimated onto a 3" liquid argon cell operating in single-phase mode (zero electric field). Organic liquid scintillators are used to tag scattered neutrons and to provide a time-of-flight measurement. The setup is designed to study light pulse shapes and scintillation yields from nuclear and electronic recoils as well as from {\\alpha}-particles at working points relevant to dark matter searches. Liquid argon offers the possibility to scrutinise scintillation yields in noble liquids with respect to the populations of the two fundamental excimer states. Here we present experimental methods and first results from recent data towards such studies.

  10. X-ray diffraction using synchrotron radiation on the G.I.L.D.A. beam line at the E.S.R.F

    Energy Technology Data Exchange (ETDEWEB)

    Balerna, A. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Meneghini, C. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)]|[INFM, Genoa (Italy); Bordoni, S. [Rome Univ. `Tor Vergata` (Italy). Dip. di Fisica; Mobilio, S. [Rome Univ. III (Italy). Dip. di Fisica `E. Amaldi`

    1996-09-01

    The aim of this lecture is to make a short introduction on Synchrotron radiation, its history and main properties. The main components of a synchrotron radiation beam line will be described. The Italian beam line, General purpose Italian beam line Line for Diffraction and Absorption (G.I.L.D.A.) at the European Synchrotron Radiation Facility (E.S.R.F.) in Grenoble will be used as an example. The G.I.L.D.A. diffractometer will be described in detail reporting also some experimental results.

  11. SU-E-T-353: Decoding the Beam Complexity in Intensity-Modulated Radiation Therapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Du, W; Cho, S; Zhang, X; Hoffman, K; Kudchadker, R [UT MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: Modern IMRT relies on computers to generate treatment plans of varied complexity. A highly complex treatment plan may use a large number of small and irregular beam apertures in order to achieve high dose conformity. However, excessive beam complexity can increase dosimetric uncertainty, prolong treatment time, and increase susceptibility to target or organ motion. In this study we sought to develop metrics to assess the complexity of IMRT beams and plans. Methods: Based the information of leaf positions and MU for each beam segment, we calculated the following beam complexity metrics: aperture area, shape irregularity, and beam modulation. Then these beam complexity metrics were averaged to obtain the corresponding plan complexity metrics, using the beam MUs as weighting factors. We evaluated and compared the beam and plan complexity scores for 65 IMRT plans from 3 sites (prostate, head and neck, and spine). We also studied how the plan complexity scores were affected by adjusting inverse planning parameters. Results: For prostate IMRT, the lateral beams had large MUs and smaller shape irregularity, while the anterior or posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest shape irregularity and beam modulation; the HN IMRT plans had the largest aperture area, shape irregularity, and beam modulation; and the spine stereotactic IMRT plans often had small aperture area, which may be associated with relatively large discrepancies between calculated and measures doses. The plan complexity increased as the number of optimization iterations and the number of beam segments increased and as the minimum segment area decreased. Conclusion: Complexity of IMRT beams and plans were quantified in terms of aperture area, shape irregularity and beam modulation. The complexity metrics varied among IMRT plans for different disease sites and were affected when the planning parameters were adjusted.

  12. Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses

    CERN Document Server

    Guido Venturini, G G; Dehning, B; Kayal, M

    2012-01-01

    An Application Specific Integrated Circuit (ASIC) has been designed and fabricated to provide a compact solution to digitize current signals from ionization chambers and diamond detectors, employed as beam loss monitors at CERN and several other high energy physics facilities. The circuit topology has been devised to accept positive and negative currents, to have a wide dynamic range (above 120 dB), withstand radiation levels over 10 Mrad and offer different modes of operation, covering a broad range of applications. Furthermore, an internal conversion reference is employed in the digitization, to provide an accurate absolute measurement. This paper discusses the detailed characterization of the first prototype: linearity, radiation tolerance and temperature dependence of the conversion, as well as implications and system-level considerations regarding its use for beam instrumentation applications in a high energy physics facility.

  13. Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy.

    Science.gov (United States)

    Sengbusch, E; Pérez-Andújar, A; DeLuca, P M; Mackie, T R

    2009-02-01

    proton kinetic energy from 250 to 200 MeV decreases the total neutron energy fluence produced by stopping a monoenergetic pencil beam in a water phantom by a factor of 2.3. It is possible to significantly lower the requirements on the maximum kinetic energy of a compact proton accelerator if the ability to treat a small percentage of patients with rotational therapy is sacrificed. This decrease in maximum kinetic energy, along with the corresponding decrease in neutron production, could lower the cost and ease the engineering constraints on a compact proton accelerator treatment facility.

  14. Evaluating the influence of 6 MV and 15 MV photon beams on prostate intensity-modulated radiation therapy plans

    Institute of Scientific and Technical Information of China (English)

    Reham A El Gendy; Ehab M Attalla; Yasser M Elkerm; Ali Alfarrash

    2016-01-01

    Objective We aimed to determine the ef ects of low- and high-energy intensity-modulated radiation therapy (IMRT) photon beams on the target volume planning and on the critical organs in the case of prostate can-cer. Methods Thirty plans were generated by using either 6 MV or 15 MV beams separately, and a combination of both 6 and 15 MV beams. Al plans were generated by using suitable planning objectives and dose con-straints, which were identical across the plans, except the beam energy. The plans were analyzed in terms of their target coverage, conformity, and homogeneity, regardless of the beam energy. Results The mean percentage values of V70 Gy for the rectal wal for the plans with 6 MV, 15 MV, and mixed-energy beams were 16.9%, 17.8%, and 16.4%, respectively, while the mean percentage values of V40 Gy were 53.6%, 52.3%, and 50.4%. The mean dose values to the femoral heads for the 6 MV, 15 MV, and mixed-en-ergy plans were 30.1 Gy, 25.5 Gy, and 25.4 Gy, respectively. The mean integral dose for the 6 MV plans was 10% larger than those for the 15 MV and mixed-energy plans. Conclusion These preliminary results suggest that mixed-energy IMRT plans may be advantageous with respect to the dosimetric characteristics of low- and high-energy beams. Although the reduction of dose to the organs at risk may not be clinical y relevant, in this study, IMRT plans using mixed-energy beams exhibited better OAR sparing and overal higher plan quality for deep-seated tumors.

  15. Guaranteed epsilon-optimal treatment plans with the minimum number of beams for stereotactic body radiation therapy.

    Science.gov (United States)

    Yarmand, Hamed; Winey, Brian; Craft, David

    2013-09-07

    Stereotactic body radiation therapy (SBRT) is characterized by delivering a high amount of dose in a short period of time. In SBRT the dose is delivered using open fields (e.g., beam's-eye-view) known as 'apertures'. Mathematical methods can be used for optimizing treatment planning for delivery of sufficient dose to the cancerous cells while keeping the dose to surrounding organs at risk (OARs) minimal. Two important elements of a treatment plan are quality and delivery time. Quality of a plan is measured based on the target coverage and dose to OARs. Delivery time heavily depends on the number of beams used in the plan as the setup times for different beam directions constitute a large portion of the delivery time. Therefore the ideal plan, in which all potential beams can be used, will be associated with a long impractical delivery time. We use the dose to OARs in the ideal plan to find the plan with the minimum number of beams which is guaranteed to be epsilon-optimal (i.e., a predetermined maximum deviation from the ideal plan is guaranteed). Since the treatment plan optimization is inherently a multi-criteria-optimization problem, the planner can navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing epsilon-optimality. We use mixed integer programming (MIP) for optimization. To reduce the computation time for the resultant MIP, we use two heuristics: a beam elimination scheme and a family of heuristic cuts, known as 'neighbor cuts', based on the concept of 'adjacent beams'. We show the effectiveness of the proposed technique on two clinical cases, a liver and a lung case. Based on our technique we propose an algorithm for fast generation of epsilon-optimal plans.

  16. Z-dependence of thick-target bremsstrahlung produced by monoenergetic low-energy electrons

    Science.gov (United States)

    Czarnecki, S.; Short, A.; Williams, S.

    2016-07-01

    The dependence of thick-target bremsstrahlung emitted by low-energy beams of monoenergetic electrons on the atomic number of the target material has been investigated experimentally for incident electron energies of 4.25 keV and 5.00 keV using thick aluminum, copper, silver, tungsten, and gold targets. Experimental data suggest that the intensity of the thick-target bremsstrahlung emitted is more strongly dependent on the atomic number of the target material for photons with energies that are approximately equal to the energy of the incident electrons than at lower energies, and also that the dependence of thick-target bremsstrahlung on the atomic number of the target material is stronger for incident electrons of higher energies than for incident electrons of lower energies. The results of the experiments are compared to the results of simulations performed using the PENELOPE program (which is commonly used in medical physics) and to thin-target bremsstrahlung theory, as well. Comparisons suggest that the experimental dependence of thick-target bremsstrahlung on the atomic number of the target material may be slightly stronger than the results of the PENELOPE code suggest.

  17. Overview of Mono-Energetic Gamma-Ray Sources and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hartemann, Fred; /LLNL, Livermore; Albert, Felicie; /LLNL, Livermore; Anderson, Scott; /LLNL, Livermore; Barty, Christopher; /LLNL, Livermore; Bayramian, Andy; /LLNL, Livermore; Chu, Tak Sum; /LLNL, Livermore; Cross, R.; /LLNL, Livermore; Ebbers, Chris; /LLNL, Livermore; Gibson, David; /LLNL, Livermore; Marsh, Roark; /LLNL, Livermore; McNabb, Dennis; /LLNL, Livermore; Messerly, Michael; /LLNL, Livermore; Shverdin, Miroslav; /LLNL, Livermore; Siders, Craig; /LLNL, Livermore; Jongewaard, Erik; /SLAC; Raubenheimer, Tor; /SLAC; Tantawi, Sami; /SLAC; Vlieks, Arnold; /SLAC; Semenov, Vladimir; /UC, Berkeley

    2012-06-25

    Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable Mono-Energetic Gamma-ray (MEGa-ray) source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC NAL will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. This MEGaray source will be used to excite nuclear resonance fluorescence in various isotopes. Applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented, along with important applications, including nuclear resonance fluorescence.

  18. Experimental determination of the response functions of a Bonner sphere spectrometer to monoenergetic neutrons

    Science.gov (United States)

    Hu, Z.; Chen, Z.; Peng, X.; Du, T.; Cui, Z.; Ge, L.; Zhu, W.; Wang, Z.; Zhu, X.; Chen, J.; Zhang, G.; Li, X.; Chen, J.; Zhang, H.; Zhong, G.; Hu, L.; Wan, B.; Gorini, G.; Fan, T.

    2017-06-01

    A Bonner sphere spectrometer (BSS) plays an important role in characterizing neutron spectra and determining their neutron dose in a neutron-gamma mixed field. A BSS consisting of a set of nine polyethylene spheres with a 3He proportional counter was developed at Peking University to perform neutron spectrum and dosimetry measurements. Response functions (RFs) of the BSS were calculated with the general Monte Carlo code MCNP5 for the neutron energy range from thermal up to 20 MeV, and were experimentally calibrated with monoenergetic neutron beams from 144 keV to 14 MeV on a 4.5 MV Van de Graaff accelerator. The calculated RFs were corrected with the experimental values, and the whole response matrix was completely established. The spectrum of a 241Am-Be source was obtained after unfolding the measurement data of the BSS to the source and in fair agreement with the expected one. The integral ambient dose equivalent corresponding to the spectrum was 0.95 of the expected value. Results of the unfolded spectrum and the integral dose equivalent measured by the BSS verified that the RFs of the BSS were well established.

  19. Analytical Solution for the Sound Radiation Field of a Viscoelastically Supported Beam Traversed by a Moving Load

    Directory of Open Access Journals (Sweden)

    Rezgar Shakeri

    2014-01-01

    Full Text Available Sound radiation from a beam resting on a viscoelastic foundation is analytically studied when it is subjected to a moving load. The topic could cover a range of applications such as submerged floating tunnels, buried pipelines, and railway tracks. Galerkin’s method is employed to obtain the transverse vibration of the beam. Based on the Rayleigh integral approach, acoustic pressure distribution around the beam is obtained in the time domain. In the second part of this paper, corresponding displacement and acoustic pressure are obtained by the use of the Rayleigh-Ritz approach in conjunction with the Laplace transform method and by the use of the Fourier transform, respectively. Durbin’s numerical Laplace transform inversion scheme is eventually employed to obtain dynamic responses. A parametric study is then carried out and influences of the design parameters as well as the loading conditions on the acoustic pressure field are investigated.

  20. Measurement and simulation of the impact of coherent synchrotron radiation on the Jefferson Laboratory energy recovery linac electron beam

    Science.gov (United States)

    Hall, C. C.; Biedron, S. G.; Edelen, A. L.; Milton, S. V.; Benson, S.; Douglas, D.; Li, R.; Tennant, C. D.; Carlsten, B. E.

    2015-03-01

    In an experiment conducted on the Jefferson Laboratory IR free-electron laser driver, the effects of coherent synchrotron radiation (CSR) on beam quality were studied. The primary goal of this work was to explore CSR output and effect on the beam with variation of the bunch compression in the IR recirculator. Here we examine the impact of CSR on the average energy loss as a function of bunch compression as well as the impact of CSR on the energy spectrum of the bunch. Simulation of beam dynamics in the machine, including the one-dimensional CSR model, shows very good agreement with the measured effect of CSR on the average energy loss as a function of compression. Finally, a well-defined structure is observed in the energy spectrum with a feature in the spectrum that varies as a function of the compression. This effect is examined in simulations, as well, and a simple explanation for the variation is proposed.

  1. Fast computation of radiation pressure force exerted by multiple laser beams on red blood cell-like particles

    Science.gov (United States)

    Gou, Ming-Jiang; Yang, Ming-Lin; Sheng, Xin-Qing

    2016-10-01

    Mature red blood cells (RBC) do not contain huge complex nuclei and organelles, makes them can be approximately regarded as homogeneous medium particles. To compute the radiation pressure force (RPF) exerted by multiple laser beams on this kind of arbitrary shaped homogenous nano-particles, a fast electromagnetic optics method is demonstrated. In general, based on the Maxwell's equations, the matrix equation formed by the method of moment (MOM) has many right hand sides (RHS's) corresponding to the different laser beams. In order to accelerate computing the matrix equation, the algorithm conducts low-rank decomposition on the excitation matrix consisting of all RHS's to figure out the so-called skeleton laser beams by interpolative decomposition (ID). After the solutions corresponding to the skeletons are obtained, the desired responses can be reconstructed efficiently. Some numerical results are performed to validate the developed method.

  2. A first-order matrix approach to the analysis of electron beam emittance growth caused by coherent synchrotron radiation

    CERN Document Server

    Hajima, R

    2003-01-01

    A first-order transform matrix is proposed for calculating electron beam emittance dilution arising from coherent synchrotron radiation (CSR) in a next-generation light source based on an energy-recovery linac. The matrix approach enables us to scan numerous parameters for the design of achromatic cells of minimum emittance dilution. The emittance dilution can be minimized when the envelope of CSR wake dispersion matches the betatron function envelope at the achromatic cell exit. (author)

  3. Sugarcane bagasse ash reinforced HDPE composites: effects of electron-beam radiation crosslinking on tensile and morphological properties

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Jaciele G.; Gomes, Michelle G.; Oliveira, Rene R.; Silva, Valquiria A.; Sartori, Mariana M.; Ortiz, Angel V.; Moura, Esperidiana A.B., E-mail: jacielegteixeira@yahoo.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Environmental issues have led to the development of polymeric materials reinforced with fibers originated from renewable agricultural sources such as pineapple leaf, sisal, jute, piassava, coir, and sugarcane bagasse. Although sugarcane bagasse fiber residues has been extensively studied and used as a source of reinforcement of polymers, the major portion of these residues is currently burnt for energy supply in the sugar and alcohol industries and as a result of its burning, tons of ashes are produced. Due to the inorganic composition, ashes can be used as reinforcement in polymeric materials. This study presents the preparation and characterization of a composite based on HDPE matrix and sugarcane bagasse ashes as reinforcement cross-linked by electron-beam radiation. The HDPE /Ash composite (95:5 wt %) was obtained by using a twin-screw extruder machine followed by injection molding. After extrusion and injection molding process, the composites were subjected to electron-beam radiation, at radiation doses of 150 kGy and 250 kGy using a Dynamitron electron beam accelerator, at room temperature in the presence of air. The irradiated and non-irradiated composite specimens were characterization by tensile and MFI tests, scanning electron microscopy (SEM), X-ray diffraction (XRD) and sol-gel analysis. In addition, ash from bagasse fiber was characterized by WDXRF. (author)

  4. Gamma and ion-beam irradiation of DNA: Free radical mechanisms, electron effects, and radiation chemical track structure

    Science.gov (United States)

    Sevilla, Michael D.; Becker, David; Kumar, Anil; Adhikary, Amitava

    2016-11-01

    The focus of our laboratory's investigation is to study the direct-type DNA damage mechanisms resulting from γ-ray and ion-beam radiation-induced free radical processes in DNA which lead to molecular damage important to cellular survival. This work compares the results of low LET (γ-) and high LET (ion-beam) radiation to develop a chemical track structure model for ion-beam radiation damage to DNA. Recent studies on protonation states of cytosine cation radicals in the N1-substituted cytosine derivatives in their ground state and 5-methylcytosine cation radicals in ground as well as in excited state are described. Our results exhibit a radical signature of excitations in 5-methylcytosine cation radical. Moreover, our recent theoretical studies elucidate the role of electron-induced reactions (low energy electrons (LEE), presolvated electrons (epre-), and aqueous (or, solvated) electrons (eaq-)). Finally DFT calculations of the ionization potentials of various sugar radicals show the relative reactivity of these species.

  5. Clinical Implementation of Intrafraction Cone Beam Computed Tomography Imaging During Lung Tumor Stereotactic Ablative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruijiang; Han, Bin; Meng, Bowen [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G.; Xing, Lei; Koong, Albert C. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Diehn, Maximilian, E-mail: Diehn@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Institute for Stem Cell Biology and Regenerative Medicine, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2013-12-01

    Purpose: To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Methods and Materials: Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during millivolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. Results: The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Conclusions: Intrafraction CBCT during VMAT can provide

  6. Petawatt laser-driven wakefield accelerator: All-optical electron injection via collision of laser pulses and radiation cooling of accelerated electron bunches.

    Science.gov (United States)

    Kalmykov, Serguei; Avitzour, Yoav; Yi, S. Austin; Shvets, Gennady

    2007-11-01

    We explore an electron injection into the laser wakefield accelerator (LWFA) using nearly head-on collision of the petawatt ultrashort (˜30 fs) laser pulse (driver) with a low- amplitude laser (seed) beam of the same duration and polarization. To eliminate the threat to the main laser amplifier we consider two options: (i) a frequency-shifted seed and (ii) a seed pulse propagating at a small angle to the axis. We show that the emission of synchrotron radiation due to betatron oscillations of trapped and accelerated electrons results in significant transverse cooling of quasi- monoenergetic accelerated electrons (with energies above 1 GeV). At the same time, the energy losses due to the synchrotron emission preserve the final energy spread of the electron beam. The ``dark current'' due to the electron trapping in multiple wake buckets and the effect of beam loading (wake destruction at the instant of beams collision) are discussed.

  7. An integrative review of skin assessment tools used to evaluate skin injury related to external beam radiation therapy.

    Science.gov (United States)

    Baines, Carol R; McGuiness, William; O'Rourke, Geraldine A

    2017-04-01

    To review literature associated with external beam radiotherapy and skin damage. A focus of the literature search is to highlight and discuss the myriad of skin assessment tools that are available to the clinician when assessing skin injury in patients receiving external beam radiation therapy. It is apparent that despite considerable work being progressed in the development of individualised skin assessment tools, uptake and use is poor. These tools are designed to assist the clinician in the evaluation of damaged skin and predict the radiation wound development pathway. An integrated review can be used to address a mature or new and emerging topic through a systematic methodology, which is either theoretical or empirical, gained from research, practice or policy initiatives (Whittemore & Knafl, Journal of Advanced Nursing, 52, 2005, 546). This review is particularly concerned with the employment of skin assessment tools by clinicians in patients with radiation damaged skin. Using the search terms synonyms for radiation, skin and epidermal damage, PubMed/MEDLINE, Medical Complete and Web of Science databases were searched. Consulting professional peers was employed as part of the inclusion and exclusion process. There is a high level of unpredictability about which patient will have an uncomplicated course of external beam radiotherapy. Variables may include, but are not limited to, an acute reaction, a delayed reaction resulting in actual skin damage or no visible skin disturbance. The skin assessment tools that are readily available are not regularly referenced in clinical practice when attempting to manage the many side effects of radiation therapy. Skin assessment tools require ongoing clinical validation, so they can be used to guide practitioners to undertake further assessment of skin integrity. The current body of knowledge suggests clinicians caring for patients receiving therapeutic radiotherapy should consider integrating a recognised patient assessment

  8. Design and fabrication of soft x-ray photolithography experimental beam line at Beijing National Synchrotron Radiation Laboratory

    Science.gov (United States)

    Zhou, Changxin

    1991-08-01

    The synchrotron radiation (SR) soft x-ray photolithography experimental beam line (3B1 beam line) at Beijing National Synchrotron Radiation Laboratory, was completed and tested in June 1990. A soft x-ray photolithography experiment was successfully completed, and the width of linear etch on a silicon chip by the device with a 3B1 beam line is up to 0.5 micrometers . This SR soft x-ray photolithography experiment was done successfully for the first time in China. This paper describes the design of the beam line and the fabrication of the most important optical element--the cylindrical scanning mirror in the beam line. The 3B1 beam line consists of the shielding light plate with water-cooling, laser simulation light source system, 3-D adjustable scanning mirror, high pass-band filer (beryllium window), acoustic sensor, helium gas chamber, and vacuum system. The main specifications of the 3B1 beam line are as follows: spectral range 0.4-2 nm; horizontal acceptance angle 7.5 mrad; vertical acceptance angle 0.4 mrad; grazing incidence angle 1.5 deg; light spot size 35 nm X 12 nm; vacuum degree of the mirror box 5 X 10-10 torr (static). The cylindrical scanning mirror in grazing incidence is used in the beam line for photolithography to obtain uniform distributed intensity of illumination of the SR source in the vertical direction (Gaussian distribution) and sufficiently concentrated energy. It is made of aluminum alloy LD2 with a supersmooth optical surface. The curvature radius of the cylindrical surface is 527.5 mm; surface figure error is less than (lambda) /10; surface roughness is better than 1 nm RMS, and fold coating on the surface of the mirror under UHV of 109 torr. The laser simulation light source system is used for adjusting the optical system in the beam line instead of the SR source. The cylindrical mirror was polished supersmoothly using Al2O3 ultra micropower grinding material made in TOMAS in Japan on modified traditional machine tools, and surface

  9. Radiation Simulations and Development of Concepts for High Power Beam Dumps, Catchers and Pre-separator Area Layouts for the Fragment Separators for RIA

    CERN Document Server

    Ronningen, Reginald; Beene, James R; Blideanu, Valetin; Boles, Jason; Bollen, Georg; Burgess, Thomas; Carter, Ken; Conner, David L; Gabriel, Tony A; Geissel, Hans; Gomes, Itacil C; Heilbronn, Lawrence; Iwase, Hiroshi; Lawton, Don; Levand, Anthony; Mansur, Louis; Momozaki, Yoichi; Morrissey, David; Nolen, Jerry; Reed, Claude; Remec, Igor; Rennich, Mark; Reyes, Susana; Sherrill, Bradley; Stein, Werner; Stoyer, Mark; Stracener, Dan; Wendel, Mark; Zeller, Al

    2005-01-01

    The development of high-power beam dumps and catchers, and pre-separator layouts for proposed fragment separators of the Rare-Isotope Accelerator (RIA) facility are important in realizing how to handle the 400 kW in the primary beam. We will present examples of pre-conceptual designs of beam dumps, fragment catchers, and the pre-separator layout. We will also present examples of ongoing work on radiation simulations using the heavy-ion-transport code PHITS, characterizing the secondary radiation produced by the high-power ion beams interacting with these devices. Results on radiation heating of targets, magnet coils, associated hardware and shielding, component activation, and levels of radiation dose will be presented. These initial studies will yield insight into the impact of the high-power dissipation on fragment separator design, remote handling concepts, nuclear safety and potential facility hazard classification, shielding design, civil construction design, component design, and material choices. Furth...

  10. Results of a 5-Week Schedule of Modern Total Skin Electron Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Stephen Lloyd, E-mail: stephen.morris@gstt.nhs.uk [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom); McGovern, Mark; Bayne, Sally; Wain, Mary; Child, Fiona; Whittaker, Sean [St Johns Institute of Dermatology, Guys and St Thomas Hospital, London (United Kingdom)

    2013-08-01

    Purpose: To report the outcomes of a 5-week schedule of total skin electron beam radiation therapy (TSEB) for mycosis fungoides (MF). Methods: Over 5 years, 41 patients with confirmed MF were treated with a modern TSEB technique delivering 30 Gy in 20 fractions over 5 weeks to the whole skin surface. Data were collected prospectively and entered into the skin tumor unit research database. Skin modified skin weighted assessment tool score data were collected to determine response, duration of response, survival, and toxicity. The outcomes were analyzed according to the patient's stage before TSEB, prognostic factors, and adjuvant treatments. Results: Seventeen patients were stage 1B, 19 were stage IIB, 3 were stage III, and 2 were stage IV. The overall response rate was 95%, with a complete response rate of 51%. Seventy-six percent of patients had relapsed at median follow-up of 18 months. The median time to relapse was 12 months, to systemic therapy was 15 months, and to modified skin weighted assessment tool progression above baseline was 44 months. The complete response rate was 59% in stage IB and 47% in stage IIB patients. The median time to skin relapse was longer in stage IB compared with stage IIB, 18 months versus 9 months. The median time to systemic therapy was longer in stage IB compared with stage IIB, >56 months versus 8 months. The median overall survival was 35 months: >56 months for stage IB, 25 months for stage IIB, 46 months for stage III, and 23.5 months for stage IV. Fifteen patients received adjuvant psoralen + ultraviolet A treatment with no difference seen in the time to relapse. Conclusions: This 5-week schedule of TSEB for MF has a high response rate with comparable duration of response to other regimens. Future studies are needed to find adjuvant and combination treatments to improve the duration of response.

  11. Long-term results of intraoperative electron beam radiation therapy for nonmetastatic locally advanced pancreatic cancer

    Science.gov (United States)

    Chen, Yingtai; Che, Xu; Zhang, Jianwei; Huang, Huang; Zhao, Dongbing; Tian, Yantao; Li, Yexiong; Feng, Qinfu; Zhang, Zhihui; Jiang, Qinglong; Zhang, Shuisheng; Tang, Xiaolong; Huang, Xianghui; Chu, Yunmian; Zhang, Jianghu; Sun, Yuemin; Zhang, Yawei; Wang, Chengfeng

    2016-01-01

    Abstract To assess prognostic benefits of intraoperative electron beam radiation therapy (IOERT) in patients with nonmetastatic locally advanced pancreatic cancer (LAPC) and evaluate optimal adjuvant treatment after IOERT. A retrospective cohort study using prospectively collected data was conducted at the Cancer Hospital of the Chinese Academy of Medical Sciences, China National Cancer Center. Two hundred forty-seven consecutive patients with nonmetastatic LAPC who underwent IOERT between January 2008 and May 2015 were identified and included in the study. Overall survival (OS) was calculated from the day of IOERT. Prognostic factors were examined using Cox proportional hazards models. The 1-, 2-, and 3-year actuarial survival rates were 40%, 14%, and 7.2%, respectively, with a median OS of 9.0 months. On multivariate analysis, an IOERT applicator diameter < 6 cm (hazards ratio [HR], 0.67; 95% confidence interval [CI], 0.47–0.97), no intraoperative interstitial sustained-release 5-fluorouracil chemotherapy (HR, 0.46; 95% CI, 0.32–0.66), and receipt of postoperative chemoradiotherapy followed by chemotherapy (HR, 0.11; 95% CI, 0.04–0.25) were significantly associated with improved OS. Pain relief after IOERT was achieved in 111 of the 117 patients, with complete remission in 74 and partial remission in 37. Postoperative complications rate and mortality were 14.0% and 0.4%, respectively. Nonmetastatic LAPC patients with smaller size tumors could achieve positive long-term survival outcomes with a treatment strategy incorporating IOERT and postoperative adjuvant treatment. Chemoradiotherapy followed by chemotherapy might be a recommended adjuvant treatment strategy for well-selected cases. Intraoperative interstitial sustained-release 5-fluorouracil chemotherapy should not be recommended for patients with nonmetastatic LAPC. PMID:27661028

  12. Hormonal changes after localized prostate cancer treatment. Comparison between external beam radiation therapy and radical prostatectomy.

    Science.gov (United States)

    Planas, J; Celma, A; Placer, J; Maldonado, X; Trilla, E; Salvador, C; Lorente, D; Regis, L; Cuadras, M; Carles, J; Morote, J

    2016-11-01

    To determine the influence of radical prostatectomy (RP) and external beam radiation therapy (EBRT) on the hypothalamic pituitary axis of 120 men with clinically localized prostate cancer treated with RP or EBRT exclusively. 120 patients with localized prostate cancer were enrolled. Ninety two patients underwent RP and 28 patients EBRT exclusively. We measured serum levels of luteinizing hormone, follicle stimulating hormone (FSH), total testosterone (T), free testosterone, and estradiol at baseline and at 3 and 12 months after treatment completion. Patients undergoing RP were younger and presented a higher prostate volume (64.3 vs. 71.1 years, p<0.0001 and 55.1 vs. 36.5 g, p<0.0001; respectively). No differences regarding serum hormonal levels were found at baseline. Luteinizing hormone and FSH levels were significantly higher in those patients treated with EBRT at three months (luteinizing hormone 8,54 vs. 4,76 U/l, FSH 22,96 vs. 8,18 U/l, p<0,0001) while T and free testosterone levels were significantly lower (T 360,3 vs. 414,83ng/dl, p 0,039; free testosterone 5,94 vs. 7,5pg/ml, p 0,018). At 12 months FSH levels remained significantly higher in patients treated with EBRT compared to patients treated with RP (21,01 vs. 8,51 U/l, p<0,001) while T levels remained significantly lower (339,89 vs. 402,39ng/dl, p 0,03). Prostate cancer treatment influences the hypothalamic pituitary axis. This influence seems to be more important when patients with prostate cancer are treated with EBRT rather than RP. More studies are needed to elucidate the role that prostate may play as an endocrine organ. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Controlled Betatron X-Ray Radiation from Tunable Optically Injected Electrons

    CERN Document Server

    Corde, S; Fitour, R; Faure, J; Tafzi, A; Goddet, J P; Malka, V; Rousse, A

    2011-01-01

    The features of Betatron x-ray emission produced in a laser-plasma accelerator are closely linked to the properties of the relativistic electrons which are at the origin of the radiation. While in interaction regimes explored previously the source was by nature unstable, following the fluctuations of the electron beam, we demonstrate in this Letter the possibility to generate x-ray Betatron radiation with controlled and reproducible features, allowing fine studies of its properties. To do so, Betatron radiation is produced using monoenergetic electrons with tunable energies from a laser-plasma accelerator with colliding pulse injection [J. Faure et al., Nature (London) 444, 737 (2006)]. The presented study provides evidence of the correlations between electrons and x-rays, and the obtained results open significant perspectives toward the production of a stable and controlled femtosecond Betatron x-ray source in the keV range.

  14. Controlled Betatron X-ray radiation from tunable optically injected electrons

    CERN Document Server

    Corde, S; Fitour, R; Faure, J; Tafzi, A; Goddet, J P; Malka, V; Rousse, A

    2011-01-01

    The features of Betatron X-ray emission produced in a laser-plasma accelerator are closely linked to the properties of the relativistic electrons which are at the origin of the radiation. While in interaction regimes explored previously the source was by nature unstable, following the fluctuations of the electron beam, we demonstrate in this Letter the possibility to generate X-ray Betatron radiation with controlled and reproducible features, allowing fine studies of its properties. To do so, Betatron radiation is produced using monoenergetic electrons with tunable energies from a laser-plasma accelerator with colliding pulse injection [J. Faure et al., Nature (London), 444, 737 (2006)]. The presented study provides evidence of the correlations between electrons and X-rays, and the obtained results open significant perspectives toward the production of a stable and controlled femtosecond Betatron X-ray source in the keV range.

  15. Evaluation of the sealing properties and TMA study of multilayer PA/PE film treated with e-beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, Angel V.; Gargalaka Junior, Joao [UNIPAC Embalagens Ltda., Sao Paulo, SP (Brazil)]. E-mail: angel.ortiz@unipacnet.com.br; joao.gargalaka@unipacnet.com.br; Wiebeck, Helio [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica]. E-mail: hwiebeck@usp.br

    2007-07-01

    Multilayer films are widely used in the food industry as thermoforming as well as non thermoforming vacuum packaging. In this study a PA6/LDPE multilayer film underwent E-beam radiation and its sealing properties were evaluated over 3 years after the film was irradiated. Packaging materials have been widely processed by ionizing radiation in order to improve their chemical and physical properties and also for sterilization purposes. Basically, flexible packaging manufacturers apply specific radiation doses to promote cross-linking and scission of the polymeric chains and thus obtain alterations in certain properties. While enhancing a specific property, significant losses may result in others. We examined the effects of E-beam radiation on the sealing properties of the multilayer film irradiated with doses up to 127 kGy. Results showed that as doses go up, the sealing strength goes down. The TMA study shows that the softening/melting temperatures of the LDPE layer (sealing layer) varies according to the irradiation doses and helps explain the results of the sealing strength tests. (author)

  16. Radiosensitivity and Induction of Apoptosis by High LET Carbon Ion Beam and Low LET Gamma Radiation: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Atanu Ghorai

    2014-01-01

    Full Text Available Cancer treatment with high LET heavy ion beam, especially, carbon ion beam (12C, is becoming very popular over conventional radiotherapy like low LET gamma or X-ray. Combination of Poly(ADP-ribose polymerase (PARP inhibitor with xenotoxic drugs or conventional radiation (gamma or X-ray is the newer approach for cancer therapy. The aim of our study was to compare the radiosensitivity and induction of apoptosis by high LET 12C and low LET gamma radiation in HeLa and PARP-1 knocked down cells. We did comet assay to detect DNA breaks, clonogenic survival assay, and cell cycle analysis to measure recovery after DNA damage. We measured apoptotic parameters like nuclear fragmentation and caspase-3 activation. DNA damage, cell killing, and induction of apoptosis were significantly higher for 12C than gamma radiation in HeLa. Cell killing and apoptosis were further elevated upon knocking down of PARP-1. Both 12C and gamma induced G2/M arrest although the 12C had greater effect. Unlike the gamma, 12C irradiation affects DNA replication as detected by S-phase delay in cell cycle analysis. So, we conclude that high LET 12C has greater potential over low LET gamma radiation in killing cells and radiosensitization upon PARP-1 inhibition was several folds greater for 12C than gamma.

  17. Computation of radiation pressure force exerted on arbitrary shaped homogeneous particles by high-order Bessel vortex beams using MLFMA.

    Science.gov (United States)

    Yang, Minglin; Wu, Yueqian; Ren, Kuan Fang; Sheng, Xinqing

    2016-11-28

    Due to special characteristics of nondiffraction and self reconstruction, the Bessel beams have attracted wide attention in optical trapping and appear to be a dramatic alternative to Gaussian beams. We present in this paper an efficient approach based on the surface integral equations (SIE) to compute the radiation pressure force (RPF) exerted on arbitrary shaped homogeneous particles by high-order Bessel vortex beam (HOBVB). The incident beam is described by vector expressions perfectly satisfy Maxwell's equations. The problem is formulated with the combined tangential formulation (CTF) and solved iteratively with the aid of the multilevel fast multipole algorithm (MLFMA). Then RPF is computed by vector flux of the Maxwell's stress tensor over a spherical surface tightly enclosing the particle and analytical expression for electromagnetic fields of incident beam in near region are used. The numerical predictions are compared with the results of the rigorous method for spherical particle to validate the accuracy of the approach. Some numerical results on relative large particles of complex shape, such as biconcave cell-like particles with different geometry parameters are given, showing powerful capability of our approach. These results are expected to provide useful insights into the RPF exerted on complex shaped particles by HOBVB.

  18. Radiation Therapy

    Science.gov (United States)

    ... the area is stitched shut. Another treatment, called proton-beam radiation therapy , focuses the radiation on the ... after radiation treatment ends. Sore mouth and tooth decay. If you received radiation therapy to the head ...

  19. Correlations between values of daily horizontal beam and global radiation for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Ianetz, A. (Bar-Ilan Univ., Ramat-Gan (Israel). Dept. of Geography Israel Meteorological Service, Bet Dagan (Israel). Research and Development Dept.); Kudish, A.I. (Ben-Gurion Univ. of the Negev, Beersheba (Israel). Dept. of Chemical Engineering)

    1994-07-01

    Three different correlation formats were tested, based on the linear beam fraction and the exponential and linear beam transmittances. The most recent 12 months of data were reserved to validate the empirical regression correlations and to compare their predictive utilities. The results of analysis for this site showed that replacing the beam fraction with beam transmittance as the dependent variable did not improve the predictive capability of the correlations significantly. The linear beam-transmittance correlations were somewhat inferior to the usual linear beam fraction format. Also, the performance of the exponential-beam transmittance relative to the linear-beam-fraction correlations was erratic (viz. superior for some months and inferior for others). The predictive capabilities for the seasonal correlations were comparable to those for the individual monthly correlations. The correlations for both the linear-beam-fraction and exponential-beam-transmittance formats varied significantly throughout the year, with values of the average monthly coefficients of variation varying from <10% to >20%. (author)

  20. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Energy Technology Data Exchange (ETDEWEB)

    Paroli, B., E-mail: bruno.paroli@unimi.it [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Mostacci, A. [“La Sapienza” University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN-LNF, via E. Fermi, 00044 Frascati (Italy); Petrillo, V.; Potenza, M.A.C.; Rossi, A.R.; Serafini, L. [Dipartimento di Fisica, Universitá degli Studi di Milano and INFN Sezione di Milano, via G. Celoria, 16, 20133 Milano (Italy)

    2015-07-15

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1–10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF)

  1. Coherence properties and diagnostics of betatron radiation emitted by an externally-injected electron beam propagating in a plasma channel

    Science.gov (United States)

    Paroli, B.; Chiadroni, E.; Ferrario, M.; Mostacci, A.; Petrillo, V.; Potenza, M. A. C.; Rossi, A. R.; Serafini, L.

    2015-07-01

    A 3-dimensional time-domain simulation of X-ray produced by a laser wakefield accelerated electron beam was performed in order to know its properties like intensity, spectrum, divergence and coherence. Particular attention was paid to the coherence around the acceleration axis. The broad spectrum of betatron radiation (1-10 keV) leads to a short coherence length. Nevertheless we observe that under particular detection condition the spatial coherence has a characteristic enlargement. We give a simplified interpretation of this effect in terms of phase shift of the electric field on a virtual detector. Moreover we describe a near field scattering technique to characterize the betatron radiation. This diagnostics will be used to map the transverse spatio-temporal coherence of X-ray radiation in the laser wakefield accelerator under development at Frascati National Laboratories (LNF).

  2. A Novel Diagnostics of Ultrashort Electron Bunches Based on Detection of Coherent Radiation from Bunched Electron Beam in an Undulator

    CERN Document Server

    Saldin, Evgeny L; Yurkov, Mikhail V

    2004-01-01

    We propose a new method for measurements of the longitudinal profile of 100 femtosecond electron bunches for X-ray Free Electron Lasers (XFELs). The method is based on detection of coherent undulator radiation produced by modulated electron beam. Seed optical quantum laser is used to produce exact optical replica of ultrashort electron bunches. The replica is generated in apparatus which consists of an input undulator (energy modulator), and output undulator (radiator) separated by a dispersion section. The radiation in the output undulator is excited by the electron bunch modulated at the optical wavelength and rapidly reaches a hundred-MW-level power. We then use the now-standard method of ultrashort laser pulse-shape measurement, a tandem combination of autocorrelator and spectrum (FROG -- frequency resolved optical gating) providing real-time single-shot measurements of the electron bunch structure. The big advantage of proposed technique is that it can be used to determine the slice energy spread and emi...

  3. Response of a lithium gadolinium borate scintillator in monoenergetic neutron fields.

    Science.gov (United States)

    Williams, A M; Beeley, P A; Spyrou, N M

    2004-01-01

    Accurate estimation of neutron dose requires knowledge of the neutron energy distribution in the working environment. Existing neutron spectrometry systems, Bonner spheres for example, are large and bulky, and require long data acquisition times. A portable system that could indicate the approximate neutron energy spectrum in a short time would be extremely useful in radiation protection. A composite scintillator, consisting of lithium gadolinium borate crystals in a plastic scintillator matrix, produced by Photogenics is being tested for this purpose. A prototype device based on this scintillator and digital pulse processing electronics has been calibrated using quasi-monoenergetic neutron fields at the low-scatter facility of the UK National Physical Laboratory (NPL). Energies selected were 144, 250, 565, 1400, 2500 and 5000 keV, with correction for sc