WorldWideScience

Sample records for monitoring volume ii

  1. DART II documentation. Volume III. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    The DART II is a remote, interactive, microprocessor-based data acquistion system suitable for use with air monitors. This volume of DART II documentation contains the following appendixes: adjustment and calibration procedures; mother board signature list; schematic diagrams; device specification sheets; ROM program listing; 6800 microprocessor instruction list, octal listing; and cable lists. (RWR)

  2. Site Environmental Report for 1998 Volume II

    International Nuclear Information System (INIS)

    Ruggieri, Michael

    1999-01-01

    Volume II of the Site Environment Report for 1998 is provided by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to the report printed in volume I. Volume II contains the environmental monitoring and sampling data used to generate summary results in the main report for routine and non routine activities at the Laboratory (except for groundwater sampling data, which may be found in the reports referred to in chapter 6). Data presented in the tables are given in International System of Units (SI) units of measure

  3. Technical summary of Groundwater Quality Protection Program at Savannah River Plant. Volume II. Radioactive waste

    International Nuclear Information System (INIS)

    Stone, J.A.; Christensen, E.J.

    1983-12-01

    This report (Volume II) presents representative monitoring data for radioactivity in groundwater at SRP. Four major groups of radioactive waste disposal sites and three minor sites are described. Much of the geohydrological and and other background information given in Volume I is applicable to these sites and is incorporated by reference. Several of the sites that contain mixed chemical and radioactive wastes are discussed in both Volumes I and II. Bulk unirradiated uranium is considered primarily a chemical waste which is addressed in Volume I, but generally not in Volume II

  4. IMAGE information monitoring and applied graphics software environment. Volume 4. Applications description

    International Nuclear Information System (INIS)

    Hallam, J.W.; Ng, K.B.; Upham, G.L.

    1986-09-01

    The EPRI Information Monitoring and Applied Graphics Environment (IMAGE) system is designed for 'fast proto-typing' of advanced concepts for computer-aided plant operations tools. It is a flexible software system which can be used for rapidly creating, dynamically driving and evaluating advanced operator aid displays. The software is written to be both host computer and graphic device independent. This four volume report includes an Executive Overview of the IMAGE package (Volume 1), followed by Software Description (Volume II), User's Guide (Volume III), and Description of Example Applications (Volume IV)

  5. Site Environmental Report for 2005 Volume I and Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, Michael

    2006-07-07

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current

  6. Antimicrobial Exposure Assessment Task Force II (AEATF II) Volume 5: Governing Document for a Multi-Year Antimicrobial Chemical Exposure Monitoring Program (interim draft document)

    Science.gov (United States)

    Describes the overall scope of the AEATF II program, demonstrates the need for additional human exposure monitoring data and explains the proposed methodology for the exposure monitoring studies proposed for conduct by the AEATF II.

  7. Antimicrobial Exposure Assessment Task Force II (AEATF II) Volume 5: Governing Document for a Multi-Year Antimicrobial Chemical Exposure Monitoring Program (interim draft document with changes)

    Science.gov (United States)

    This document describes the overall scope of the AEATF II program, demonstrates the need for additional human exposure monitoring data and explains the proposed methodology for the exposure monitoring studies proposed for conduct by the AEATF II.

  8. Final report on Phase II remedial action at the former Middlesex Sampling Plant and associated properties. Volume 2

    International Nuclear Information System (INIS)

    1985-04-01

    Volume 2 presents the radiological measurement data taken after remedial action on properties surrounding the former Middlesex Sampling Plant during Phase II of the DOE Middlesex Remedial Action Program. Also included are analyses of the confirmatory radiological survey data for each parcel with respect to the remedial action criteria established by DOE for the Phase II cleanup and a discussion of the final status of each property. Engineering details of this project and a description of the associated health physics and environmental monitoring activities are presented in Volume 1

  9. Lunar Health Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — During the Phase II Lunar Health Monitor program, Orbital Research will develop a second generation wearable sensor suite for astronaut physiologic monitoring. The...

  10. Smolt Monitoring Program, Volume II, Migrational Characteristics of Columbia Basin Salmon and Steelhead Trout, 1986 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Fish Passage Center

    1987-02-01

    Smolt Monitoring Program Annual Report, 1986, Volume I, describes the results of travel time monitoring and other migrational characteristics of yearling and sub-yearling chinook salmon (Oncorhynchus tshawytscha), sockeye salmon (Oncorhynchus nerka), and steelhead trout (Salmo gairdneri). This volume presents the data from Fish Passage Center freeze brands used in the analysis of travel time for Lewiston, Lower Granite, Lower Monumental, Rock Island, McNary, and John Day dams. Summary of data collection procedures and explanation of data listings are presented in conjunction with the mark recapture data. Data for marked fish not presented in this report will be provided upon request. Daily catch statistics (by species), flow, and sample parameters for the smolt monitoring sites, Clearwater, Lewiston, Lower Granite, Lower Monumental, Rock Island, McNary, John Day, and Bonneville also will be provided upon request.

  11. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  12. Development of a new monitor for tritium in air model TAM-II

    International Nuclear Information System (INIS)

    Wu Bin; Yang Hailan; Wen Xuelian; Zhao Yi; Yang Huaiyuan

    2001-01-01

    The author introduces development of a real-time continuous tritium monitor model TAM-II. The detector of the instrument is comprised of four geometric-symmetry open wall ionization chamber with the effective volume of 2 L, which enables to minimize the remember effect of the ionization chamber due to contamination by the monitored tritium. It is γ background compensation rate is better than 97% in almost all direction. The detector is equipped with a FET static electrometer working in micro-current integration mode. The measurement process of the tritium monitor can be controlled automatically by a micro-processor sheet, such as automatic range changing, data displaying and storing, and data processing. The measuring range is 6 - 10 6 Bq/L. It is especially application for monitoring tritium in off-gas effluence from glove-box or stack of tritium facility and laboratory

  13. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  14. An Independent Scientific Assessment of Well Stimulation in California Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Bachmann, Corinne E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Camarillo, Mary Kay [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Domen, Jeremy K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Foxall, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Houseworth, James [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jin, Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Jordan, Preston D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKone, Thomas E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Millstein, Dev E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Reagan, Matthew T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sandelin, Whitney L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stringfellow, William T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Varadharajan, Charuleka [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cooley, Heather [Pacific Inst., Oakland, CA (United States); Donnelly, Kristina [Pacific Inst., Oakland, CA (United States); Heberger, Matthew G. [Pacific Inst., Oakland, CA (United States); Hays, Jake [PSE Healthy Energy, Berkeley, CA (United States); Shonkoff, Seth B.C. [PSE Healthy Energy, Berkeley, CA (United States); Brandt, Adam [Stanford Univ., CA (United States); Englander, Jacob G. [Stanford Univ., CA (United States); Hamdoun, Amro [Univ. of California of San Diego, La Jolla, CA (United States); Nicklisch, Sascha C.T. [Univ. of California of San Diego, La Jolla, CA (United States); Harrison, Robert J. [Univ. of California, San Francisco, CA (United States); Wettstein, Zachary S. [Univ. of California, San Francisco, CA (United States); Banbury, Jenner [California State Univ. Stanislaus, Turlock, CA (United States); Cypher, Brian L. [California State Univ. Stanislaus, Turlock, CA (United States); Phillips, Scott E. [California State Univ. Stanislaus, Turlock, CA (United States)

    2015-07-01

    This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, the present volume, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, also issued in July 2015, presents case studies that assess environmental issues and qualitative risks for specific geographic regions. A final Summary Report summarizes key findings, conclusions and recommendations of all three volumes.

  15. Liquid volume monitoring based on ultrasonic sensor and Arduino microcontroller

    Science.gov (United States)

    Husni, M.; Siahaan, D. O.; Ciptaningtyas, H. T.; Studiawan, H.; Aliarham, Y. P.

    2016-04-01

    Incident of oil leakage and theft in oil tank often happens. To prevent it, the liquid volume insides the tank needs to be monitored continuously. Aim of the study is to calculate the liquid volume inside oil tank on any road condition and send the volume data and location data to the user. This research use some ultrasonic sensors (to monitor the fluid height), Bluetooth modules (to sent data from the sensors to the Arduino microcontroller), Arduino Microcontroller (to calculate the liquid volume), and also GPS/GPRS/GSM Shield module (to get location of vehicle and sent the data to the Server). The experimental results show that the accuracy rate of monitoring liquid volume inside tanker while the vehicle is in the flat road is 99.33% and the one while the vehicle is in the road with elevation angle is 84%. Thus, this system can be used to monitor the tanker position and the liquid volume in any road position continuously via web application to prevent illegal theft.

  16. 2000 Physical Acoustics Summer School (PASS 00). Volume II: Transparencies

    National Research Council Canada - National Science Library

    Bass, Henry

    2001-01-01

    .... Volume II of these proceedings contains copies of the transparencies used by the lecturers and Volume III contains background materials that were sent to student and discussion leader participants...

  17. Reinforced soil structures. Volume II, Summary of research and systems information

    Science.gov (United States)

    1989-11-01

    Volume II was essentially prepared as an Appendix of supporting information for Volume I. This volume contains much of the supporting theory and a summary of the research used to verify the design approach contained in Volume I, as well as general in...

  18. Crew Cerebral Oxygen Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II SBIR proposal is aimed at developing a non-invasive, optical method for monitoring crew member state of awareness in operational environments. All...

  19. THE EFFECT OF TELE-MONITORING ON EXERCISE TRAINING ADHERENCE, FUNCTIONAL CAPACITY, QUALITY OF LIFE AND GLYCEMIC CONTROL IN PATIENTS WITH TYPE II DIABETES

    Directory of Open Access Journals (Sweden)

    Tracy Marios

    2012-03-01

    Full Text Available We used tele-monitoring to attempt to improve exercise adherence (number of hours of exercise completed, peak VO2, HbA1c% and quality of life in an unsupervised, home based exercise program in people with type II diabetes, a cost analysis was also conducted. Thirty-nine patients with type II diabetes were randomized to tele-monitoring (TELE or control (CON groups. All patients were asked to complete 6 months exercise training and complete an exercise activity diary. The TELE group was instructed to record their exercise heart rates using a monitor and received weekly telephone calls from an exercise physiologist. Six TELE patients and seven CON patients did not complete the 6 month testing. TELE patients completed a mean weekly volume of 138 minutes, moderate intensity exercise, while CON patients completed 58 minutes weekly (p < 0.02. Neither group achieved the American Heart Association statement guideline for weekly exercise volume of 150 minutes. TELE patients improved peak VO2 (5.5 %, but neither group improved HbA1c% or quality of life. The CON group showed a 4.9% reduction in peak VO2. While tele-monitored patients completed more hours of exercise and demonstrated improved peak VO2 compared to controls, the exercise volume completed was insufficient to improve glycemic control. There is the potential via tele-monitoring to enable people with diabetes to meet exercise training guidelines.

  20. Introduction to "Global Tsunami Science: Past and Future, Volume II"

    Science.gov (United States)

    Rabinovich, Alexander B.; Fritz, Hermann M.; Tanioka, Yuichiro; Geist, Eric L.

    2017-08-01

    Twenty-two papers on the study of tsunamis are included in Volume II of the PAGEOPH topical issue "Global Tsunami Science: Past and Future". Volume I of this topical issue was published as PAGEOPH, vol. 173, No. 12, 2016 (Eds., E. L. Geist, H. M. Fritz, A. B. Rabinovich, and Y. Tanioka). Three papers in Volume II focus on details of the 2011 and 2016 tsunami-generating earthquakes offshore of Tohoku, Japan. The next six papers describe important case studies and observations of recent and historical events. Four papers related to tsunami hazard assessment are followed by three papers on tsunami hydrodynamics and numerical modelling. Three papers discuss problems of tsunami warning and real-time forecasting. The final set of three papers importantly investigates tsunamis generated by non-seismic sources: volcanic explosions, landslides, and meteorological disturbances. Collectively, this volume highlights contemporary trends in global tsunami research, both fundamental and applied toward hazard assessment and mitigation.

  1. Environmental Pollution: Noise Pollution - Sonic Boom. Volume I.

    Science.gov (United States)

    Defense Documentation Center, Alexandria, VA.

    The unclassified, annotated bibliography is Volume I of a two-volume set on Noise Pollution - Sonic Boom in a series of scheduled bibliographies on Environmental Pollution. Volume II is Confidential. Corporate author-monitoring agency, subject, title, contract, and report number indexes are included. (Author/JR)

  2. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  3. Monitoring of the storage facility Asse II

    International Nuclear Information System (INIS)

    Regenauer, Urban; Wittwer, Christiane

    2012-01-01

    The storage facility Asse II is former salt mine near Wolfenbuettel in Niedersachsen. From 1967 to 1978 totally 125787 barrels with low-and medium-level radioactive wastes were disposed in the salt cavern. Since 1988 ingress of saturated brines from the adjoining rocks were observed in the mine. An extensive monitoring concept was installed for the surveillance of possible radionuclides released with the mine air into the surrounding. The report is aimed to n describe the actual situation in the salt mine Asse II with special emphasis to the monitoring concept. The discussion is based on the history of the storage facility that was primarily a research mine. Furthermore a regional accompanying process is described that was created in 2007.

  4. HYDRA-II: A hydrothermal analysis computer code: Volume 1, Equations and numerics

    International Nuclear Information System (INIS)

    McCann, R.A.

    1987-04-01

    HYDRA-II is a hydrothermal computer code capable of three-dimensional analysis of coupled conduction, convection, and thermal radiation problems. This code is especially appropriate for simulating the steady-state performance of spent fuel storage systems. The code has been evaluated for this application for the US Department of Energy's Commercial Spent Fuel Management Program. HYDRA-II provides a finite difference solution in Cartesian coordinates to the equations governing the conservation of mass, momentum, and energy. A cylindrical coordinate system may also be used to enclose the Cartesian coordinate system. This exterior coordinate system is useful for modeling cylindrical cask bodies. The difference equations for conservation of momentum are enhanced by the incorporation of directional porosities and permeabilities that aid in modeling solid structures whose dimensions may be smaller than the computational mesh. The equation for conservation of energy permits of modeling of orthotropic physical properties and film resistances. Several automated procedures are available to model radiation transfer within enclosures and from fuel rod to fuel rod. The documentation of HYDRA-II is presented in three separate volumes. This volume, Volume I - Equations and Numerics, describes the basic differential equations, illustrates how the difference equations are formulated, and gives the solution procedures employed. Volume II - User's Manual contains code flow charts, discusses the code structure, provides detailed instructions for preparing an input file, and illustrates the operation of the code by means of a model problem. The final volume, Volume III - Verification/Validation Assessments, presents results of numerical simulations of single- and multiassembly storage systems and comparisons with experimental data. 4 refs

  5. Survey of Biomass Gasification, Volume II: Principles of Gasification

    Energy Technology Data Exchange (ETDEWEB)

    Reed, T.B. (comp.)

    1979-07-01

    Biomass can be converted by gasification into a clean-burning gaseous fuel that can be used to retrofit existing gas/oil boilers, to power engines, to generate electricity, and as a base for synthesis of methanol, gasoline, ammonia, or methane. This survey describes biomass gasification, associated technologies, and issues in three volumes. Volume I contains the synopsis and executive summary, giving highlights of the findings of the other volumes. In Volume II the technical background necessary for understanding the science, engineering, and commercialization of biomass is presented. In Volume III the present status of gasification processes is described in detail, followed by chapters on economics, gas conditioning, fuel synthesis, the institutional role to be played by the federal government, and recommendations for future research and development.

  6. Activity report 1990-1992 and proceedings. Volume II

    International Nuclear Information System (INIS)

    Mayer-Rosa, D.; Waniek, L.; Suhadolc, P.

    1993-01-01

    A report of the European Seismological Commission (ESC) on 1990-1992 activities and Proceedings of the General Assembly of the ESC are presented in two volumes. Volume II covers the following topics: study of seismic sound, seismotectonic analysis, deep seismic sounding, the three-dimensional structure of the European lithosphere-asthenosphere system, complexity in earthquake occurrence, earthquake hazard, strong and weak earthquake ground motions, macroseismology, microzonation, and applications in earthquake engineering. One paper dealing with the connection between seismicity and the CO 2 - 222 Rn content in spring water has been inputted to INIS. (Z.S.)

  7. Lawrence Berkeley National Laboratory 1995 site environmental report: Volume 2, Data appendix

    International Nuclear Information System (INIS)

    1996-07-01

    Ernest Orlando Lawrence Berkeley National Laboratory presents Volume II, Data Appendix as a reference document to supplement the 1995 Site Environmental Report. Volume II contains the raw environmental monitoring and sampling data used to generate many of the summary results included in the main report. Supplemental data is provided for sitewide activities involving the media of stack and ambient air quality, rainwater, surface water, stormwater, wastewater, and soil and sediment. Volume II also contains supplemental data on the special preoperational monitoring study for the new Hazardous Waste Handling Facility. The Table of Contents provides a cross-reference to the data tables of the main report and this appendix. Data are given in System International (SI) units

  8. Environmental contaminants in food. Volume II-part a: working papers. I. Priority setting of toxic substances for guiding monitoring programs. II. Five case studies of environmental food contamination

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Priority setting of toxic substances for guiding monitoring programs; and (2) Five case studies of environmental food contamination

  9. 1987 Oak Ridge model conference: Proceedings: Volume 2, Environmental protection

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    See the abstract for Volume I for general information on the conference. Topics discussed in Volume II include data management techiques for environmental protection efforts, the use of models in environmental auditing, in emergency plans, chemical accident emergency response, risk assessment, monitoring of waste sites, air and water monitoring of waste sites, and in training programs. (TEM)

  10. 1987 Oak Ridge model conference: Proceedings: Volume 2, Environmental protection

    International Nuclear Information System (INIS)

    1987-01-01

    See the abstract for Volume I for general information on the conference. Topics discussed in Volume II include data management techiques for environmental protection efforts, the use of models in environmental auditing, in emergency plans, chemical accident emergency response, risk assessment, monitoring of waste sites, air and water monitoring of waste sites, and in training programs

  11. Savannah River Site Approved Site Treatment Plan, 2001 Annual Update (Volumes I and II)

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, B.

    2001-04-30

    The Compliance Plan Volume (Volume I) identifies project activity scheduled milestones for achieving compliance with Land Disposal Restrictions. Information regarding the technical evaluation of treatment options for SRS mixed wastes is contained in the Background Volume (Volume II) and is provided for information.

  12. Tokamak experimental power reactor conceptual design. Volume II

    International Nuclear Information System (INIS)

    1976-08-01

    Volume II contains the following appendices: (1) summary of EPR design parameters, (2) impurity control, (3) plasma computational models, (4) structural support system, (5) materials considerations for the primary energy conversion system, (6) magnetics, (7) neutronics penetration analysis, (8) first wall stress analysis, (9) enrichment of isotopes of hydrogen by cryogenic distillation, and (10) noncircular plasma considerations

  13. Developing and Evaluating Prototype of Waste Volume Monitoring Using Internet of Things

    Science.gov (United States)

    Fathhan Arief, Mohamad; Lumban Gaol, Ford

    2017-06-01

    In Indonesia, especially Jakarta have a lot of garbage strewn that can be an eyesore and also cause pollution that can carry diseases. Garbage strewn can cause many things, one of her dues is bins are overflowing due to the full so it can not accommodate the waste dumped from other people. Thus, the author created a new method for waste disposal more systematic. In creating new method requires a technology to supports, then the author makes a prototype for waste volume monitoring. By using the internet of things prototype of waste volume monitoring may give notification to the sanitary agency that waste in the trash bin needs to be disposal. In this study, conducted the design and manufactured of prototype waste volume monitoring using LinkItONE board based by Arduino and an ultrasonic sensor for appliance senses. Once the prototype is completed, evaluation in order to determine whether the prototype will function properly. The result showed that the expected function of a prototype waste volume monitoring can work well.

  14. Compact, High Accuracy CO2 Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase II proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  15. Site Environmental Report for 2012, Volumes 1& 2

    Energy Technology Data Exchange (ETDEWEB)

    Pauer, Ron; Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Thorson, Patrick; Wahl, Linnea; Wehle, Petra; Xu, Suying; None

    2013-09-30

    This report provides a comprehensive summary of the environmental program activities at LBNL for the calendar year 2012. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

  16. Phonons: Theory and experiments II. Volume 2

    International Nuclear Information System (INIS)

    Bruesch, P.

    1986-01-01

    The present second volume titled as ''Phonons: Theory and Experiments II'', contains, a thorough study of experimental techniques and the interpretation of experimental results. This three-volume set tries to bridge the gap between theory and experiment, and is addressed to those working in both camps in the vast field of dynamical properties of solids. Topics presented in the second volume include; infrared-, Raman and Brillouin spectroscopy, interaction of X-rays with phonons, and inelastic neutron scattering. In addition an account is given of some other techniques, including ultrasonic methods, inelastic electron tunneling spectroscopy, point contact spectroscopy, and spectroscopy of surface phonons, thin films and adsorbates. Both experimental aspects and theoretical concepts necessary for the interpretation of experimental data are discussed. An attempt is made to present the descriptive as well as the analytical aspects of the topics. Simple models are often used to illustrate the basic concepts and more than 100 figures are included to illustrate both theoretical and experimental results. Many chapters contain a number of problems with hints and results giving additional information

  17. CDF run II run control and online monitor

    International Nuclear Information System (INIS)

    Arisawa, T.; Ikado, K.; Badgett, W.; Chlebana, F.; Maeshima, K.; McCrory, E.; Meyer, A.; Patrick, J.; Wenzel, H.; Stadie, H.; Wagner, W.; Veramendi, G.

    2001-01-01

    The authors discuss the CDF Run II Run Control and online event monitoring system. Run Control is the top level application that controls the data acquisition activities across 150 front end VME crates and related service processes. Run Control is a real-time multi-threaded application implemented in Java with flexible state machines, using JDBC database connections to configure clients, and including a user friendly and powerful graphical user interface. The CDF online event monitoring system consists of several parts: the event monitoring programs, the display to browse their results, the server program which communicates with the display via socket connections, the error receiver which displays error messages and communicates with Run Control, and the state manager which monitors the state of the monitor programs

  18. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring

    Science.gov (United States)

    Parvaz, Muhammad A.; Maloney, Thomas; Moeller, Scott J.; Malaker, Pias; Konova, Anna B.; Alia-Klein, Nelly; Goldstein, Rita Z.

    2014-01-01

    Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC) in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume) influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs) to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component) of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A) acquiring the same data from individuals with cocaine use disorder (CUD), known to have deficits in executive function including behavioral monitoring; and (B) acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females) healthy individuals and 25 (42.7 ± 5.9 years; 6 females) individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300) in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC–N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations. PMID:24918068

  19. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring

    Directory of Open Access Journals (Sweden)

    Muhammad A. Parvaz

    2014-01-01

    Full Text Available Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A acquiring the same data from individuals with cocaine use disorder (CUD, known to have deficits in executive function including behavioral monitoring; and (B acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females healthy individuals and 25 (42.7 ± 5.9 years; 6 females individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300 in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC–N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations.

  20. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring.

    Science.gov (United States)

    Parvaz, Muhammad A; Maloney, Thomas; Moeller, Scott J; Malaker, Pias; Konova, Anna B; Alia-Klein, Nelly; Goldstein, Rita Z

    2014-01-01

    Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC) in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume) influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs) to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component) of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A) acquiring the same data from individuals with cocaine use disorder (CUD), known to have deficits in executive function including behavioral monitoring; and (B) acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females) healthy individuals and 25 (42.7 ± 5.9 years; 6 females) individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300) in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC-N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations.

  1. TIBER II/ETR final design report: Volume 2, 3.0 Engineering

    International Nuclear Information System (INIS)

    Lee, J.D.

    1987-09-01

    This paper discusses the design of the TIBER II Tokamak. This particular volume discusses: mechanical systems; electrical systems; shield nuclear analysis and tritium issues; reactor building facilities; and tritium systems

  2. Heater test planning for the Near Surface Test Facility at the Hanford reservation. Volume II. Appendix

    International Nuclear Information System (INIS)

    DuBois, A.; Binnall, E.; Chan, T.; McEvoy, M.; Nelson, P.; Remer, J.

    1979-04-01

    Volume II contains the following information: theoretical support for radioactive waste storage projects - development of data analysis methods and numerical models; injectivity temperature profiling as a means of permeability characterization; geophysical holes at the Near Surface Test Facility (NSTF), Hanford; proposed geophysical and hydrological measurements at NSTF; suggestions for characterization of the discontinuity system at NSTF; monitoring rock property changes caused by radioactive waste storage using the electrical resistivity method; microseismic detection system for heated rock; Pasco Basin groundwater contamination study; a letter to Mark Board on Gable Mountain Faulting; report on hydrofracturing tests for in-situ stress measurement, NSTF, Hole DC-11, Hanford Reservation; and borehole instrumentation layout for Hanford Near Surface Test Facility

  3. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  4. Mn(II), Zn(II) and VO(II) Schiff

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 113; Issue 3. Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II) Schiff base complexes derived from o-phenylenediamine and acetoacetanilide. N Raman Y Pitchaikani Raja A Kulandaisamy. Inorganic Volume 113 Issue 3 June 2001 pp 183-189 ...

  5. The consideration and practice of data processing of WBS-II portal β monitor

    International Nuclear Information System (INIS)

    Du Xiangyang; Dong Qiangmin; Zhang Yong; Han Shuping; Wang Xiaodong; Fan Liya; Rao Xianming

    2001-01-01

    The main aspects of background and human body measurement data processing of WBS-II Portal β Monitor were discussed. The theory analysis of setting high and low background-warning threshold in data processing was done. The relative reference values were partly provided to the local executives. The measurement 'blind zone' and the whole warning function of data processing were discussed. And the structure, the process of monitoring and the microcomputer's hard wares of WBS-II Portal β Monitor were simply introduced

  6. Composite Structure Monitoring using Direct Write Sensors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This NASA SBIR Phase II project seeks to develop and demonstrate a suite of sensor products to monitor the health of composite structures. Sensors will be made using...

  7. International and Domestic Market Opportunities for Biomass Power: Volumes I and II

    Energy Technology Data Exchange (ETDEWEB)

    1998-09-01

    This report examines the domestic and international markets for biopower. Domestic and foreign markets present fundamentally different challenges to private power developers. Volume I focuses on the domestic market for biopower. The domestic challenge lies in finding economically viable opportunities for biopower. Vol. I outlines the current state of the U.S. biomass industry, discusses policies affecting biomass development, describes some demonstration projects currently underway, and discusses the future direction of the industry. Volume II focuses on the international market for biopower. Recent literature states that the electricity investment and policy climate in foreign markets are the key elements in successful private project development. Vol. II discusses the financing issues, policy climate, and business incentives and barriers to biopower development. As India and China are the largest future markets for biopower, they are the focus of this volume. Three other top markets- -Brazil, Indonesia, and the Philippines--are also discussed. Potential financial resources wrap up the discussion.

  8. Minerals Yearbook, volume II, Area Reports—Domestic

    Science.gov (United States)

    ,

    2018-01-01

    The U.S. Geological Survey (USGS) Minerals Yearbook discusses the performance of the worldwide minerals and materials industries and provides background information to assist in interpreting that performance. Content of the individual Minerals Yearbook volumes follows:Volume I, Metals and Minerals, contains chapters about virtually all metallic and industrial mineral commodities important to the U.S. economy. Chapters on survey methods, summary statistics for domestic nonfuel minerals, and trends in mining and quarrying in the metals and industrial mineral industries in the United States are also included.Volume II, Area Reports: Domestic, contains a chapter on the mineral industry of each of the 50 States and Puerto Rico and the Administered Islands. This volume also has chapters on survey methods and summary statistics of domestic nonfuel minerals.Volume III, Area Reports: International, is published as four separate reports. These regional reports contain the latest available minerals data on more than 180 foreign countries and discuss the importance of minerals to the economies of these nations and the United States. Each report begins with an overview of the region’s mineral industries during the year. It continues with individual country chapters that examine the mining, refining, processing, and use of minerals in each country of the region and how each country’s mineral industry relates to U.S. industry. Most chapters include production tables and industry structure tables, information about Government policies and programs that affect the country’s mineral industry, and an outlook section.The USGS continually strives to improve the value of its publications to users. Constructive comments and suggestions by readers of the Minerals Yearbook are welcomed.

  9. Subseabed disposal program annual report, January-December 1979. Volume II. Appendices (principal investigator progress reports). Part 2 of 2

    International Nuclear Information System (INIS)

    Talbert, D.M.

    1981-04-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume II, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-O; Part 2 contains Appendices P-FF. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base

  10. Site Environmental Report for 1999 - Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, M

    2000-08-12

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The Site Environmental Report for 1999 is intended to summarize Berkeley Lab's compliance with environmental standards and requirements, characterize environmental management efforts through surveillance and monitoring activities, and highlight significant programs and efforts for calendar year 1999. The report is separated into two volumes. Volume I contains a general overview of the Laboratory, the status of environmental programs, and summary results from surveillance and monitoring activities. Each chapter in Volume I begins with an outline of the sections that follow, including any tables or figures found in the chapter. Readers should use section numbers (e.g., {section}1.5) as navigational tools to find topics of interest in either the printed or the electronic version of the report. Volume II contains the individual data results from monitoring programs.

  11. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  12. Subseabed disposal program annual report, January-December 1980. Volume II. Appendices (principal investigator progress reports). Part 1

    International Nuclear Information System (INIS)

    Hinga, K.R.

    1981-07-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-Q; Part 2 contains Appendices R-MM. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base

  13. Subseabed disposal program annual report, January-December 1980. Volume II. Appendices (principal investigator progress reports). Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Hinga, K.R. (ed.)

    1981-07-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-Q; Part 2 contains Appendices R-MM. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base.

  14. National Environmental Policy Act compliance guide. Volume II (reference book)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This document (Volume II of the National Environmental Policy Act Compliance Guide) contains current copies of regulations and guidance from the Council on Environmental Quality, the Department of Energy, the Department of State, and the Environmental Protection Agency, related to compliance with the National Environmental Policy Act of 1969 (NEPA).

  15. Technology transfer package on seismic base isolation - Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume II contains the proceedings for the Short Course on Seismic Base Isolation held in Berkeley, California, August 10-14, 1992.

  16. Controlled air incinerator for radioactive waste. Volume II. Engineering design references manual

    International Nuclear Information System (INIS)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-11-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities

  17. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  18. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  19. A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring

    Science.gov (United States)

    Huang, Haiyu; Chen, Pai-Yen; Hung, Cheng-Hsien; Gharpurey, Ranjit; Akinwande, Deji

    2016-01-01

    Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor, and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.

  20. Volume traps - a new retrospective radon monitor

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-11-01

    A new method to trace back average radon concentrations in dwellings over several decades in time has been developed. This retrospective radon monitor is based on the measurement of the alpha activity of 210 Po deposited in volume traps, for example spongy materials used for mattresses and cushions. Polyester samples with different densities have been exposed to radon-laden air. The exposures correspond to characteristic radon concentrations between 390 Bq/m 3 and 3.9 Bq/m 3 over a 20 years period. The precision in converting the 210 Po signal to the radon exposure has been improved by more than one order of magnitude compared to other common techniques. It is shown that this very sensitive method may be applied to almost all types of volume traps used in households

  1. Real-time bladder volume monitoring by the application of a new implantable bladder volume sensor for a small animal model

    Directory of Open Access Journals (Sweden)

    Dong Sup Lee

    2011-04-01

    Full Text Available Although real-time monitoring of bladder volume together with intravesical pressure can provide more information for understanding the functional changes of the urinary bladder, it still entails difficulties in the accurate prediction of real-time bladder volume in urodynamic studies with small animal models. We studied a new implantable bladder volume monitoring device with eight rats. During cystometry, microelectrodes prepared by the microelectromechanical systems process were placed symmetrically on both lateral walls of the bladder, and the expanded bladder volume was calculated. Immunohistological study was done after 1 week and after 4 weeks to evaluate the biocompatibility of the microelectrode. From the point that infused saline volume into the bladder was higher than 0.6 mL, estimated bladder volume was statistically correlated with the volume of saline injected (p<0.01. Additionally, the microelectromechanical system microelectrodes used in this study showed reliable biocompatibility. Therefore, the device can be used to evaluate changes in bladder volume in studies with small animals, and it may help to provide more information about functional changes in the bladder in laboratory studies. Furthermore, owing to its biocompatibility, the device could be chronically implanted in conscious ambulating animals, thus allowing a novel longitudinal study to be performed for a specific purpose.

  2. S-1 project. Volume II. Hardware. 1979 annual report

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This volume includes highlights of the design of the Mark IIA uniprocessor (SMI-2), and the SCALD II user's manual. SCALD (structured computer-aided logic design system) cuts the cost and time required to design logic by letting the logic designer express ideas as naturally as possible, and by eliminating as many errors as possible - through consistency checking, simulation, and timing verification - before the hardware is built. (GHT)

  3. HFS-II hands and feet contamination monitor for α, β

    International Nuclear Information System (INIS)

    Du Xiangyang; Han Shuping; Wang Xiaodong; Fan Liya; Zhang Yong; Rao Xianming; Fang Jintu

    1999-11-01

    HFS-II Hands and Feet Contamination Monitor for α, β is a necessary device which monitors the entrance of controlling area of nuclear power plant and nuclear facility, and it consists of nuclear detector, nuclear electronic circuit, computer data processing and controlling divisions, input/output controlling etc. Physical indicators conform to the requirements of relative national standard GB8703-87 and department standard EJ/T586

  4. Site Environmental Report for 2008, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Regina; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea; Xu, Suying

    2009-09-21

    The Site Environmental Report for 2008 is an integrated report on the environmental programs at Lawrence Berkeley National Laboratory and satisfies the requirements of DOE order 231.1A, Environment, Safety, and Health Reporting. Volume II contains individual data results from surveillance and monitoring activities

  5. 12 CFR Appendix II to Part 27 - Information for Government Monitoring Purposes

    Science.gov (United States)

    2010-01-01

    ... II Appendix II to Part 27 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY... Monitoring Purposes The following language is approved by the Comptroller of the Currency and will satisfy... used separately. This information may also be provided orally by the applicant. The following...

  6. Forest Focus Monitoring Database System - Technical Report 2003 Level II Data

    OpenAIRE

    HIEDERER ROLAND; DURRANT TRACY; GRANKE O.; LAMBOTTE Michel; LORENZ M.; MIGNON B.; OEHMICHEN K.

    2007-01-01

    Forest Focus (Regulation (EC) No 2152/2003) is a Community scheme for harmonized, broad-based, comprehensive and long-term monitoring of European forest ecosystems. Under this scheme the monitoring of air pollution effects on forests is carried out by participating countries on the basis of the systematic network of observation points (Level I) and of the network of observation plots for intensive and continuous monitoring (Level II). According to Article 15(1) of the Forest Focus Regulat...

  7. Forest Focus Monitoring Database System - Technical Report 2006 Level II Data

    OpenAIRE

    HIEDERER Roland; DURRANT Tracy; GRANKE Oliver; LAMBOTTE Michel; LORENZ Martin; MIGNON Bertrand

    2008-01-01

    Forest Focus (Regulation (EC) No 2152/2003) is a Community scheme for harmonized, broadbased, comprehensive and long-term monitoring of European forest ecosystems. Under this scheme the monitoring of air pollution effects on forests is carried out by participating countries on the basis of the systematic network of observation points (Level I) and of the network of observation plots for intensive and continuous monitoring (Level II). According to Article 15(1) of the Forest Focus Regulatio...

  8. Site Environmental Report for 2002, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Pauer, Ron

    2003-07-01

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The ''Site Environmental Report for 2002'' summarizes Berkeley Lab's compliance with environmental standards and requirements, characterizes environmental management efforts through surveillance and monitoring activities, and highlights significant programs and efforts for calendar year 2002. Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab,'' ''the Laboratory,'' ''Lawrence Berkeley National Laboratory,'' and ''LBNL.'' The report is separated into two volumes. Volume I contains a general overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from the monitoring programs. This year, the ''Site Environmental Report'' was distributed on a CD in PDF format that includes Volume I, Volume II, and related documents. The report is also available on the Web at http://www.lbl.gov/ehs/esg/. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are additionally reported using the more conventional (non-SI) system of measurements because this system is referenced by some current regulatory standards and is more familiar to some readers. The tables included at the end of the Glossary are intended to help readers understand the various prefixes used with SI units of measurement and convert these units from one system to the other.

  9. Job monitoring on DIRAC for Belle II distributed computing

    Science.gov (United States)

    Kato, Yuji; Hayasaka, Kiyoshi; Hara, Takanori; Miyake, Hideki; Ueda, Ikuo

    2015-12-01

    We developed a monitoring system for Belle II distributed computing, which consists of active and passive methods. In this paper we describe the passive monitoring system, where information stored in the DIRAC database is processed and visualized. We divide the DIRAC workload management flow into steps and store characteristic variables which indicate issues. These variables are chosen carefully based on our experiences, then visualized. As a result, we are able to effectively detect issues. Finally, we discuss the future development for automating log analysis, notification of issues, and disabling problematic sites.

  10. Soil microbiology in land reclamation volume II - mycorrhizae

    Energy Technology Data Exchange (ETDEWEB)

    Graves, D.H. (ed.)

    1984-01-01

    This volume contains three separate reports: RRTAC 84-4 (Greenhouse pot studies dealing with amendment of oil sand tailings: effects of peat, sewage sludge and fertilizer on plant growth, mycorrhizae and microbial activity); RRTAC 84-8 (Vesicular-arbuscular mycorrhizal (VAM) development of slender wheatgrass on amended oil sand tailings and subalpine coal mines spoil); RRTAC 84-7 (Ectomycorrhizae in amended oil sand tailings and subalpine coal mine spoil and in undisturbed Jack pine and spruce stands). In the first report mixtures of two peats were used to amend oil sand tailings and either mineral fertilizers or sewage sludge were added at different rates. The growth of slender wheat grass and jack pine grown in the greenhouse in these media were monitored. In the second report the VAM development of slender wheatgrass was monitored over a 4 year period; in the third the mycorrhizal status of jack pine and bear berry grown in oil sand tailings treated with various amendments and of white spruce and willow grown in subalpine coal mine spoil were monitored over the same period.

  11. Site Environmental Report for 2011, Volumes 1& 2

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Rothermich, Nancy; Thorson, Patrick; Wahl, Linnea; Xu, Suying

    2012-09-12

    The Site Environmental Report for 2011 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2011. Throughout this report, “Berkeley Lab” or “LBNL” refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

  12. Proceedings of the natural gas RD&D contractors review meeting, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Malone, R.D. [ed.

    1995-04-01

    This is volume II of papers which were presented at the natural gas RD&D contractors review meeting. Topics include: natural gas upgrading, storage, well drilling, completion, and stimulation. Individual papers were processed separately for the United States Department of Energy databases.

  13. Subseabed disposal program annual report, January-December 1979. Volume II. Appendices (principal investigator progress reports). Part 1 of 2

    International Nuclear Information System (INIS)

    Talbert, D.M.

    1981-04-01

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-O; Part 2 contains Appendices P-FF. Separate abstracts have been prepared of each Appendix for inclusion in the Energy Data Base

  14. Simulation model for wind energy storage systems. Volume II. Operation manual. [SIMWEST code

    Energy Technology Data Exchange (ETDEWEB)

    Warren, A.W.; Edsinger, R.W.; Burroughs, J.D.

    1977-08-01

    The effort developed a comprehensive computer program for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic). An acronym for the program is SIMWEST (Simulation Model for Wind Energy Storage). The level of detail of SIMWEST is consistent with a role of evaluating the economic feasibility as well as the general performance of wind energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. Volume II, the SIMWEST operation manual, describes the usage of the SIMWEST program, the design of the library components, and a number of simple example simulations intended to familiarize the user with the program's operation. Volume II also contains a listing of each SIMWEST library subroutine.

  15. Remote sensing for environmental monitoring and resource management. Volume 2

    International Nuclear Information System (INIS)

    1992-01-01

    The subject of this volume is remote sensing for environmental monitoring and resource management. This session is divided in eight parts. First part is on general topics, methodology and meteorology. Second part is on geology, environment and land cover. Third part is on disaster monitoring. Fourth part is on operational status of remote sensing. Fifth part is on coastal zones and inland waters. Sixth and seventh parts are on forestry and agriculture. Eighth part is on instrumentation and systems. (A.B.). refs., figs., tabs

  16. Mechanical Behaviour of Materials Volume II Fracture Mechanics and Damage

    CERN Document Server

    François, Dominique; Zaoui, André

    2013-01-01

    Designing new structural materials, extending lifetimes and guarding against fracture in service are among the preoccupations of engineers, and to deal with these they need to have command of the mechanics of material behaviour. This ought to reflect in the training of students. In this respect, the first volume of this work deals with elastic, elastoplastic, elastoviscoplastic and viscoelastic behaviours; this second volume continues with fracture mechanics and damage, and with contact mechanics, friction and wear. As in Volume I, the treatment links the active mechanisms on the microscopic scale and the laws of macroscopic behaviour. Chapter I is an introduction to the various damage phenomena. Chapter II gives the essential of fracture mechanics. Chapter III is devoted to brittle fracture, chapter IV to ductile fracture and chapter V to the brittle-ductile transition. Chapter VI is a survey of fatigue damage. Chapter VII is devoted to hydogen embrittlement and to environment assisted cracking, chapter VIII...

  17. Monitoring the snowpack volume in a sinkhole on Mount Lebanon using time lapse Photogrammetry

    Science.gov (United States)

    Abou Chakra, C.; Gascoin, S.; Somma, J.; Drapeau, L.; Fanise, P.

    2017-12-01

    Lebanon is one of the richest country in the Middle East for water resources, thanks to its mountain ranges that trigger precipitation from the moist air masses coming from the Mediterranean Sea. Snowpack acts as natural water storage in winter and supply fresh water during spring and summer. Yet, Lebanon is facing a serious water scarcity problem due to: i) decreasing amount of precipitation and climate change; ii) major growth of population of original residence and large number of refugees during regional wars. Therefore, continuous and systematic monitoring of the Lebanese water resources is becoming crucial. The Mount Lebanon is made of karstic depressions named "sinkholes". It is important to monitor the snowmelt process inside these sinkholes because of their key role as "containers" of seasonal snow. By isolating the snowpack from sun radiation and wind, they slow down the natural melting process and sublimation, thus delaying as well the low water flow period. An observatory is set up to monitor the snowpack evolution in a pilot sinkhole located in Mount Lebanon. The system uses three time-lapse cameras and structure-from-motion principles to reconstruct the snow volume within the sinkhole. The approach is validated by standard topographic surveys. The results indicate that snow depth can be retrieved with an accuracy between 20 and 60 cm (residuals standard deviation) and a low bias of 50 cm after coregistration of the digital elevation models.

  18. Tank waste source term inventory validation. Volume II. Letter report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories.

  19. Tank waste source term inventory validation. Volume II. Letter report

    International Nuclear Information System (INIS)

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories

  20. Infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide.

    Science.gov (United States)

    Kong, Chang Yi; Siratori, Tomoya; Funazukuri, Toshitaka; Wang, Guosheng

    2014-10-03

    The effects of temperature and density on retention of platinum(II) 2,4-pentanedionate in supercritical fluid chromatography were investigated at temperatures of 308.15-343.15K and pressure range from 8 to 40MPa by the chromatographic impulse response method with curve fitting. The retention factors were utilized to derive the infinite dilution partial molar volumes of platinum(II) 2,4-pentanedionate in supercritical carbon dioxide. The determined partial molar volumes were small and positive at high pressures but exhibited very large and negative values in the highly compressible near critical region of carbon dioxide. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Three Mile Island: a report to the commissioners and to the public. Volume II, Part 3

    International Nuclear Information System (INIS)

    1979-01-01

    This is the third and final part of the second volume of a study of the Three Mile Island accident. Part 3 of Volume II contains descriptions and assessments of responses to the accident by the utility and by the NRC and other government agencies

  2. Los Alamos Controlled Air Incinerator for radioactive waste. Volume II. Engineering design reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-10-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities.

  3. Los Alamos Controlled Air Incinerator for radioactive waste. Volume II. Engineering design reference manual

    International Nuclear Information System (INIS)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-10-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities

  4. Kilowatt isotope power system, Phase II Plan. Volume IV. Teledyne FSCD vs GDS

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-15

    This Volume contains Teledyne's input to the Kilowatt Isotope Power System Phase II Plan. Included is a description of the Flight System Heat Generation System, Flight System Radiator, Thermal Insulation Stability, GDS Heat Generation System and GDS Radiator.

  5. Biennial Survey of Education, 1916-18. Volume II. Bulletin, 1919, No. 89

    Science.gov (United States)

    Bureau of Education, Department of the Interior, 1921

    1921-01-01

    Volume II of the Biennial Survey of Education, 1916-1918 includes the following chapters: (1) Education in Great Britain and Ireland (I. L. Kandel); (2) Education in parts of the British Empire: Educational Developments in the Dominion of Canada (Walter A. Montgomery), Public School System of Jamaica (Charles A. Asbury), Recent Progress of…

  6. Proceedings of the 1995 U.S. DOE hydrogen program review. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The 1995 US DOE Hydrogen Program Review was held April 18-21, 1995 in Coral Gables, FL. Volume II of the Proceedings contains 8 papers presented under the subject of hydrogen storage and 17 papers presented on hydrogen production. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  7. On-line sodium and cover as purity monitors gas operating tools at EBR-II

    International Nuclear Information System (INIS)

    Smith, C.R.F.; Richardson, W.J.; Holmes, J.T.

    1976-01-01

    Plugging temperature indicators, electrochemical oxygen meters and hydrogen diffusion meters are the on-line sodium purity monitors now in use at EBR-II. On-line gas chromatographs are used to monitor helium, hydrogen, oxygen and nitrogen impurities in the argon cover gases. Monitors for tritium-in-sodium and for hydrocarbons-in-cover gas have been developed and are scheduled for installation in the near future. An important advantage of on-line monitors over the conventional grab-sampling techniques is the speed of response to changing reactor conditions. This helps us to identify the source of the impurity, whether the cause may be transient or constant, and take corrective action as necessary. The oxygen meter is calibrated monthly against oxygen in sodium determined by the vanadium wire equilibration method. The other instruments either do not require calibration or are self-calibrating. The ranges, sensitivity and response times of all of the on-line purity monitors has proven satisfactory under EBR-II operating conditions

  8. Energy extension service pilot program evaluation report: the first year. Volume II: pilot state reports

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    Volume II of the Energy Extension Service Evaluation presents a discussion of the operations of the ten EES pilot-state programs during the period from October 1, 1977 through September 30, 1978. Each of the ten pilot states - Alabama, Connecticut, Michigan, New Mexico, Pennsylvania, Tennessee, Texas, Washington, Wisconsin, and Wyoming - received a grant of approximately $1.1 million to develop and implement a 19-month program beginning on October 1, 1977. Volume II provides a case-study description of the operations of the pilot program in each state, with special attention given to the two programs selected in each state for more detailed study and survey research. Some survey data and analysis are presented for the emphasis programs.

  9. MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

    Science.gov (United States)

    Saeed, M.; Lieu, C.; Raber, G.; Mark, R. G.

    2002-01-01

    Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

  10. Annual report on radioactive discharges and monitoring of the environment 1992. V. 1

    International Nuclear Information System (INIS)

    1993-01-01

    This Annual Report supplements and updates the Company's Environment Annual Report by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment since 1977. This year the report is again sub-divided into two complementary volumes. Volume I consists of site papers, one for each of the Company's sites and includes annual data on radioactive discharges into the environment and the associated environmental monitoring programmes. Critical group doses for each site are presented in summary tables at the beginning of each Site paper. Volume II reproduces the Certificates of Authorisation regulating the Company's discharges and the statutory environmental monitoring programmes which relate to them. (Author)

  11. Radiation protection instrumentation. Monitoring equipment. Radioactive aerosols in the environment

    International Nuclear Information System (INIS)

    1996-01-01

    This international standard applies to portable or installed equipment for continuous monitoring of radioactive aerosols in the environment in normal and emergency conditions. Monitoring involves continuous sampling and, where desirable, automatic start of sampling. The document applies particularly to the following assignments: (i) determination of the volume activity of radionuclides in the form of aerosols, either per time unit, along with its time changes, or in the integral form over a longer time period such as 24 h, and measurement of the volume sampled; (ii) triggering a warning alarm signal if the preset volume activity or time integral of the volume activity of aerosols has been exceeded. The document deals with radioactive aerosol monitor design, testing procedures, and documentation. Appended tables refer to the reference and normal testing conditions, tests in normal testing conditions, tests during changes of the affecting quantities, and tests of the air circuit. (P.A.)

  12. Efficacy of lung volume optimization maneuver monitored by optoelectronic pletismography in the management of congenital diaphragmatic hernia

    Directory of Open Access Journals (Sweden)

    G. Lista

    2017-01-01

    We report a case of left CDH with severe lung hypoplasia, managed applying open lung strategy in HFOV (pre-surgery period and in Assist-Control with Volume Guarantee (post-surgery period, guided by SpO2 changes, TcPO2 and TcPCO2 monitoring. Opto-electronic plethysmography was used to measure end-expiratory chest wall volume changes (ΔEEcw related to lung volume variations occurring during pressure changes. OEP confirmed the efficacy of using SpO2 and transcutaneous gas monitoring during this recruitment maneuver.

  13. Preliminary feasibility study on storage of radioactive wastes in Columbia River basalts. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    ,

    1976-11-01

    Volume II comprises four appendices: analytical data and sample locations for basalt flow type localities; Analytical data and sample locations for measured field sections in Yakima basalts; core hole lithology and analytical data; and geophysical logs. (LK)

  14. Proceedings of the advanced coal-fired power systems `95 review meeting, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, H.M.; Mollot, D.J.; Venkataraman, V.K.

    1995-06-01

    This report contains papers which were presented at the advanced coal-fired power sytems review meeting. This is volume II. Topics include: hot gas filter issues, hazardous air pollutants, sorbent development, and separation technologies. Individual papers were processed separately for the United States Department of Energy databases.

  15. On-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    International Nuclear Information System (INIS)

    Davis, E.; Rasmussen, B.

    2004-01-01

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system

  16. Recommended criteria for the evaluation of on-site nuclear power plant emergency plans, volume II: criteria

    International Nuclear Information System (INIS)

    1997-01-01

    A critical review of existing Canadian and international nuclear power plant (NPP) emergency plans, evaluation criteria, and approaches has been conducted to provide AECB staff with information which can be used to assess the adequacy of NPP on-site emergency response plans. The results of this work are published in two volumes. Volume I, Basis Document, provides the reasons why certain requirements are in place. It also gives comprehensive references to various standards.Volume II, Criteria, contains the criteria which relate to on-site actions and their integration with control room activities and the roles of off-site responsible organizations. The recommended criteria provide information on what is required, and not on how to accomplish the requirements. The licensees are given the latitude to decide on the methods and processes needed to meet the requirements. The documents do not address NPP off-site plans and response capability, or the control room emergency operating procedures and response capability. This report contains only Volume II: Criteria. 55 refs., 2 tabs., 1 fig

  17. Proceedings of the 1984 DOE nuclear reactor and facility safety conference. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    This report is a collection of papers on reactor safety. The report takes the form of proceedings from the 1984 DOE Nuclear Reactor and Facility Safety Conference, Volume II of two. These proceedings cover Safety, Accidents, Training, Task/Job Analysis, Robotics and the Engineering Aspects of Man/Safety interfaces.

  18. Proceedings of the 1984 DOE nuclear reactor and facility safety conference. Volume II

    International Nuclear Information System (INIS)

    1984-01-01

    This report is a collection of papers on reactor safety. The report takes the form of proceedings from the 1984 DOE Nuclear Reactor and Facility Safety Conference, Volume II of two. These proceedings cover Safety, Accidents, Training, Task/Job Analysis, Robotics and the Engineering Aspects of Man/Safety interfaces

  19. M-area hazardous waste management facility groundwater monitoring and corrective-action report, First quarter 1995, Volume 1

    International Nuclear Information System (INIS)

    1995-05-01

    This report, in three volumes, describes the ground water monitoring and c corrective-action program at the M-Area Hazardous Waste Management Facility (HWMF) at the Savannah River Site (SRS) during the fourth quarter 1994 and first quarter 1995. Concise description of the program and considerable data documenting the monitoring and remedial activities are included in the document. This is Volume 1 covering the following topics: sampling and results; hydrogeologic assessment; water quality assessment; effectiveness of the corrective-action program; corrective-action system operation and performance; monitoring and corrective-action program assessment; proposed monitoring and corrective-action program modifications. Also included are the following appendicies: A-standards; B-flagging criteria; C-figures; D-monitoring results tables; E-data quality/usability assessment

  20. Annual report on radioactive discharges and monitoring of the environment 1992. V. 1

    International Nuclear Information System (INIS)

    1993-01-01

    This Annual Report supplements the Company's Health and Safety Annual Report by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment, covering the period from 1977 to the present. For 1990 this report has been sub-divided into two complementary parts. Volume I includes annual data for each of the Company sites on radioactive discharges into the environment and the associated environmental monitoring programmes. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  1. Annual report on radioactive discharges and monitoring of the environment 1990. V. 1

    International Nuclear Information System (INIS)

    1991-01-01

    This Annual Report supplements the Company's Health and Safety Annual Report by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment, covering the period from 1977 to the present. For 1990 this report has been sub-divided into two complementary parts. Volume I includes annual data for each of the Company sites on radioactive discharges into the environment and the associated environmental monitoring programmes. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  2. Annual report on radioactive discharges and monitoring of the environment 1990. V. 2

    International Nuclear Information System (INIS)

    1991-01-01

    This Annual Report supplements the Company's Health and Safety Annual Report by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment, covering the period from 1977 to the present. For 1990 this report has been sub-divided into two complementary parts. Volume I includes annual data for each of the Company sites on radioactive discharges into the environment and the associated environmental monitoring programmes. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  3. Relative blood volume monitoring during hemodialysis in end stage renal disease patients.

    Science.gov (United States)

    Ion Titapiccolo, Jasmine; Ferrario, Manuela; Garzotto, Francesco; Cruz, Dinna; Moissl, Ulrich; Tetta, Ciro; Ronco, Claudio; Signorini, Maria G; Cerutti, Sergio

    2010-01-01

    A crucial point in the haemodialysis (HD) treatment is the reliable assessment of hydration status. An inadequate removed volume may lead to chronic fluid overload which can lead to hypertension, left ventricular hypertrophy and heart failure. Therefore, the estimation of the hydration state and the management of a well-tolerated water removal is an important challenge. This exploratory study aims at identifying new parameters obtained from continuous Blood Volume Monitoring (BVM) allowing a qualitative evaluation of hydration status for verifying the adequacy of HD setting parameters (e.g UFR, target dry weight). The percentage of blood volume reduction (BVR%) during HD was compared against a gold standard method for hydration status assessment. The slope of the first 30 minute of blood volume reduction (BVR) was proposed as a useful parameter to identify overhydrated patients.

  4. Savannah River Site Environmental Monitoring Plan. Volume 1, Section 1000 Addendum: Revision 3

    International Nuclear Information System (INIS)

    Jannik, G.T.

    1994-01-01

    This document -- the Savannah River Site Environmental Monitoring Plan (SRS EM Plan) -- has been prepared according to guidance contained in the DOE 5400 Series orders, in 10 CFR 834, and in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and environmental Surveillance [DOE, 1991]. The SRS EM Plan's purpose is to define the criteria, regulations, and guideline requirements with which SRS will comply. These criteria and requirements are applicable to environmental monitoring activities performed in support of the SRS Environmental Monitoring Program (SRS EM Program), WSRC-3Q1-2, Volume 1, Section 1100. They are not applicable to monitoring activities utilized exclusively for process monitoring/control. The environmental monitoring program requirements documented in the SRS EM Plan incorporate all applicable should requirements of DOE/EH-0173T and expand upon them to include nonradiological environmental monitoring program requirements

  5. ON-Line Monitoring of Instrument Channel Performance: Volume 3: Applications to Nuclear Power Plant Technical Specification Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    E Davis, B Rasmussen

    2004-12-31

    This report is a guide for a technical specification change submittal and subsequent implementation of on-line monitoring for safety-related applications. This report is the third in a three-volume set. Volume 1, ''Guidelines for Model Development and Implementation'', presents the various tasks that must be completed to prepare models for and to implement an on-line monitoring system.

  6. ALICE: Physics Performance Report, Volume II

    International Nuclear Information System (INIS)

    Alessandro, B; Antinori, F; Belikov, J A

    2006-01-01

    of the subsystem designs, and a description of the offline framework and Monte Carlo event generators. The present volume, Volume II, contains the majority of the information relevant to the physics performance in proton-proton, proton-nucleus, and nucleus-nucleus collisions. Following an introductory overview, Chapter 5 describes the combined detector performance and the event reconstruction procedures, based on detailed simulations of the individual subsystems. Chapter 6 describes the analysis and physics reach for a representative sample of physics observables, from global event characteristics to hard processes

  7. West Hackberry Strategic Petroleum Reserve site brine-disposal monitoring, Year I report. Volume II. Physical and chemical oceanography. Final report

    Energy Technology Data Exchange (ETDEWEB)

    DeRouen, L.R.; Hann, R.W.; Casserly, D.M.; Giammona, C.; Lascara, V.J. (eds.)

    1983-02-01

    This project centers around the Strategic Petroleum Site (SPR) known as the West Hackberry salt dome which is located in southwestern Louisiana, and which is designed to store 241 million barrels of crude oil. Oil storage caverns are formed by injecting water into salt deposits, and pumping out the resulting brine. Studies described in this report were designed as follow-on studies to three months of pre-discharge characterization work, and include data collected during the first year of brine leaching operations. The objectives were to: (1) characterize the environment in terms of physical, chemical and biological attributes; (2) determine if significant adverse changes in ecosystem productivity and stability of the biological community are occurring as a result of brine discharge; and (3) determine the magnitude of any change observed. Contents of Volume II include: introduction; physical oceanography; estuarine hydrology and hydrography; analysis of discharge plume; and water and sediment quality.

  8. Northwest Forest Plan—the first 10 years (1994–2003): socioeconomic monitoring results.

    Science.gov (United States)

    S. Charnley

    2006-01-01

    The socioeconomic monitoring report addresses two evaluation questions posed in the Northwest Forest Plan (the Plan) Record of Decision and assesses progress in meeting five Plan socioeconomic goals. Volume I of the report contains key findings. Volume II addresses the question, Are predictable levels of timber and nontimber resources available and being produced? It...

  9. Site Environmental Report for 2006. Volume I, Environment, Health, and Safety Division

    Energy Technology Data Exchange (ETDEWEB)

    None

    2007-09-30

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2006 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2006. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as “Berkeley Lab,” “the Laboratory,” “Lawrence Berkeley National Laboratory,” and “LBNL.”) The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory’s environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from surveillance and monitoring activities.

  10. Recovery of Navy distillate fuel from reclaimed product. Volume II. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Brinkman, D.W.; Whisman, M.L.

    1984-11-01

    In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). This first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in which experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 references and abstracts. This appendix, because of its volume, has been published separately as Volume 2.

  11. Nitric oxide, prostaglandins and angiotensin II in the regulation of renal medullary blood flow during volume expansion.

    Science.gov (United States)

    Moreno, Carol; Llinás, María T; Rodriguez, Francisca; Moreno, Juan M; Salazar, F Javier

    2016-03-01

    Regulation of medullary blood flow (MBF) is essential in maintaining renal function and blood pressure. However, it is unknown whether outer MBF (OMBF) and papillary blood flow (PBF) are regulated independently when extracellular volume (ECV) is enhanced. The aim of this study was to determine whether OMBF and PBF are differently regulated and whether there is an interaction between nitric oxide (NO), prostaglandins (PGs) and angiotensin II (Ang II) in regulating OMBF and PBF when ECV is enhanced. To achieve these goals, OMBF and PBF were measured by laser-Doppler in volume-expanded rats treated with a cyclooxygenase inhibitor (meclofenamate, 3 mg/kg) and/or a NO synthesis inhibitor (L-nitro-arginine methyl ester (L-NAME), 3 μg/kg/min) and/or Ang II (10 ng/kg/min). OMBF was unchanged by NO or PGs synthesis inhibition but decreased by 36 % (P blood flows to the outer medulla and renal papilla are differently regulated and showing that there is a complex interaction between NO, PGs and Ang II in regulating OMBF and PBF when ECV is enhanced.

  12. The durban beach monitoring program: simple surveys speak volumes

    CSIR Research Space (South Africa)

    de Wet, p

    2010-10-01

    Full Text Available program: simple surveys speak volumes Pierre de Wet, Andrew Mather, Andr? Theron SAEON summit, 6 October 2010 ? CSIR 2010 Slide 1www.csir.co.za Outline ? Background / History ? Monitoring area circle6 Examples of survey data & trends circle6...) and near-shore deposition cf. classical understanding / scheme ? CSIR 2010 Slide 6 ? id. areas vulnerable to erosion ? effect of replenishment rates / locations visible Beach survey data s h o r e l i n e p o s i t i o n [ m...

  13. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  14. Results of site validation experiments. Volume II. Supporting documents 5 through 14

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains the following supporting documents: Summary of Geologic Mapping of Underground Investigations; Logging of Vertical Coreholes - ''Double Box'' Area and Exploratory Drift; WIPP High Precision Gravity Survey; Basic Data Reports for Drillholes, Brine Content of Facility Internal Strata; Mineralogical Content of Facility Interval Strata; Location and Characterization of Interbedded Materials; Characterization of Aquifers at Shaft Locations; and Permeability of Facility Interval Strate.

  15. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL

    2008-12-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.

  16. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    International Nuclear Information System (INIS)

    Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.

    2008-01-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies

  17. Estimating the cold war mortgage: The 1995 baseline environmental management report. Volume II: Site summaries

    International Nuclear Information System (INIS)

    1995-03-01

    This volume, Volume II presents the site data that was used to generate the Department of Energy's (DOE) initial Baseline Environmental Management Report (BEMR). The raw data was obtained by DOE field personnel from existing information sources and anticipated environmental management strategies for their sites and was tempered by general assumptions and guidance developed by DOE Headquarters personnel. This data was then integrated by DOE Headquarters personnel and modified to ensure that overall constraints such as funding and waste management capacity were addressed. The site summaries are presented by State and broken out by discrete activities and projects. The Volume I Glossary has been repeated to facilitate the reader's review of Volume II. The information presented in the site summaries represents the best data and assumptions available as of February 1, 1995. Assumptions that have not been mandated by formal agreement with appropriate regulators and other stakeholders do not constitute decisions by the Department nor do they supersede existing agreements. In addition, actions requiring decisions from external sources regarding unknowns such as future land use and funding/scheduling alternatives, as well as internal actions such as the Department's Strategic Realignment initiative, will alter the basis and general assumptions used to generate the results for this report. Consequently, the numbers presented in the site summaries do not represent outyear budget requests by the field installations

  18. Environmental gamma radiation monitoring system with a large volume air ionization chamber

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, C.; Witzani, J.

    1986-01-01

    An improved environmental monitoring system has been designed and tested consisting of an ionization chamber with 120 l sensitive volume, operated at atmospheric pressure, and a commercial electrometer amplifier with digital voltmeter. The system is controlled by a desk calculator with printer for automated operation and calculation of dose and doserate. The ionization chamber provides superior dosimetric performance as compared to usual GM-counters and high pressure chambers. The system has been field-tested during the 'European Intercomparison Programme for Environmental Monitoring Instruments' organized by the Commission of the European Communities. (Author)

  19. Kilowatt isotope power system. Phase II plan. Volume I. Phase II program plan

    International Nuclear Information System (INIS)

    1978-01-01

    The development of a Kilowatt Isotope Power System (KIPS) was begun in 1975 for the purpose of satisfying the power requirements of satellites in the 1980's. The KIPS is a 238 PuO 2 -fueled organic Rankine cycle turbine power system to provide a design output of 500 to 2000 W. Phase II of the overall 3-phase KIPS program is described. This volume presents a program plan for qualifying the organic Rankine power system for flight test in 1982. The program plan calls for the design and fabrication of the proposed flight power system; conducting a development and a qualification program including both environmental and endurance testing, using an electrical and a radioisotope heat source; planning for flight test and spacecraft integration; and continuing ground demonstration system testing to act as a flight system breadboard and to accumulate life data

  20. Dead layer and active volume determination for GERDA Phase II detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lehnert, Bjoern [TU Dresden (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    The GERDA experiment investigates the neutrinoless double beta decay of {sup 76}Ge and is currently running Phase I of its physics program. Using the same isotope as the Heidelberg Moscow (HDM) experiment, GERDA aims to directly test the claim of observation by a subset of the HDM collaboration. For the update to Phase II of the experiment in 2013, the collaboration organized the production of 30 new Broad Energy Germanium (BEGe) type detectors from original 35 kg enriched material and tested their performance in the low background laboratory HADES in SCK.CEN, Belgium. With additional 20 kg of detectors, GERDA aims to probe the degenerated hierarchy scenario. One of the crucial detector parameters is the active volume (AV) fraction which directly enters into all physics analysis. This talk presents the methodology of dead layer and AV determination with different calibration sources such as {sup 241}Am, {sup 133}Ba, {sup 60}Co and {sup 228}Th and the results obtained for the new Phase II detectors. Furthermore, the AV fraction turned out to be the largest systematic uncertainty in the analysis of Phase I data which makes it imperative to reduce its uncertainty for Phase II. This talk addresses the major contributions to the AV uncertainty and gives an outlook for improvements in Phase II analysis.

  1. Failsafe automation of Phase II clinical trial interim monitoring for stopping rules.

    Science.gov (United States)

    Day, Roger S

    2010-02-01

    In Phase II clinical trials in cancer, preventing the treatment of patients on a study when current data demonstrate that the treatment is insufficiently active or too toxic has obvious benefits, both in protecting patients and in reducing sponsor costs. Considerable efforts have gone into experimental designs for Phase II clinical trials with flexible sample size, usually implemented by early stopping rules. The intended benefits will not ensue, however, if the design is not followed. Despite the best intentions, failures can occur for many reasons. The main goal is to develop an automated system for interim monitoring, as a backup system supplementing the protocol team, to ensure that patients are protected. A secondary goal is to stimulate timely recording of patient assessments. We developed key concepts and performance needs, then designed, implemented, and deployed a software solution embedded in the clinical trials database system. The system has been in place since October 2007. One clinical trial tripped the automated monitor, resulting in e-mails that initiated statistician/investigator review in timely fashion. Several essential contributing activities still require human intervention, institutional policy decisions, and institutional commitment of resources. We believe that implementing the concepts presented here will provide greater assurance that interim monitoring plans are followed and that patients are protected from inadequate response or excessive toxicity. This approach may also facilitate wider acceptance and quicker implementation of new interim monitoring algorithms.

  2. Airborne gamma-ray spectrometer and magnetometer survey: Cameron A, Arizona, detail area. Volume II A. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II A contains appendices for: stacked profiles; geologic histograms; geochemical histograms; speed and altitude histograms; geologic statistical tables; geochemical statistical tables; magnetic and ancillary profiles; and test line data

  3. Brookhaven National Laboratory 2008 Site Environment Report Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Brookhaven National Laboratory

    2009-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

  4. Design layout for gas monitoring system II, GMS-2, computer system

    International Nuclear Information System (INIS)

    Vo, V.; Philipp, B.L.; Manke, M.P.

    1995-01-01

    This document provides a general overview of the computer systems software that perform the data acquisition and control for the 241-SY-101 Gas Monitoring System II (GMS-2). It outlines the system layout, and contains descriptions of components and the functions they perform. The GMS-2 system was designed and implemented by Los Alamos National Laboratory and supplied to Westinghouse Hanford Company

  5. Nuclear legislation analytical study. Regulatory and institutional framework for nuclear activities in OECD member countries. Volume II

    International Nuclear Information System (INIS)

    1984-01-01

    This study is part of a series of analytical studies of the major aspects of nuclear legislation in OECD Member countries and is published in two volumes. This volume II of the study is a revision and an expansion of a 1969 study concerning the organisation and general regime governing nuclear activities. The national studies were prepared, to the extent possible, following a standard plan for all countries to facilitate information retrieval and comparison. This volume also contains tables of international conventions of relevance to the nuclear field. (NEA) [fr

  6. Discourse, Paragraph, and Sentence Structure in Selected Philippine Languages. Final Report. Volume II, Sentence Structure.

    Science.gov (United States)

    Longacre, Robert E.

    Volume II of "Discourse, Paragraph, and Sentence Structure in Selected Philippine Languages" begins with an explanation of certain assumptions and postulates regarding sentence structure. A detailed treatment of systems of sentence structure and the parameters of such systems follows. Data in the various indigenous languages are…

  7. Comparative assessment of TRU waste forms and processes. Volume II. Waste form data, process descriptions, and costs

    International Nuclear Information System (INIS)

    Ross, W.A.; Lokken, R.O.; May, R.P.; Roberts, F.P.; Thornhill, R.E.; Timmerman, C.L.; Treat, R.L.; Westsik, J.H. Jr.

    1982-09-01

    This volume contains supporting information for the comparative assessment of the transuranic waste forms and processes summarized in Volume I. Detailed data on the characterization of the waste forms selected for the assessment, process descriptions, and cost information are provided. The purpose of this volume is to provide additional information that may be useful when using the data in Volume I and to provide greater detail on particular waste forms and processes. Volume II is divided into two sections and two appendixes. The first section provides information on the preparation of the waste form specimens used in this study and additional characterization data in support of that in Volume I. The second section includes detailed process descriptions for the eight processes evaluated. Appendix A lists the results of MCC-1 leach test and Appendix B lists additional cost data. 56 figures, 12 tables

  8. The Oxford History of English Lexicography. Volume I: General ...

    African Journals Online (AJOL)

    A.P. Cowie (Editor). The Oxford History of English Lexicography. Volume I: General-purpose Dictionaries. Volume II: Specialized Dictionaries. 2009. Volume I: xviii + 467 pp., Volume II: xix + 551 pp. ISBN Volume I–II: 978-0-19-928562-4. Volume I: 978-0-19-928560-0. Volume II: 978-0-19-928561-7. Oxford: Oxford University ...

  9. World Energy Data System (WENDS). Volume II. Country data, CZ-KS

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The World Energy Data System contains organized data on those countries and international organizations that may have critical impact on the world energy scene. Included in this volume, Vol. II, are Czechoslovakia, Denmark, Egypt, Finland, France, Germany (East), Germany (West), Greece, Guinea, India, Indonesia, Iran, Italy, Japan, and Korea (South). The following topics are covered for most of the countries: economic, demographic, and educational profiles; energy policy; indigenous energy resources and uses; forecasts, demand, exports, imports of energy supplies; environmental considerations of energy use; power production facilities; energy industries; commercial applications of energy; research and development activities of energy; and international activities.

  10. Forecasting the Future Food Service World of Work. Final Report. Volume II. Centralized Food Service Systems. Service Management Reports.

    Science.gov (United States)

    Powers, Thomas F., Ed.; Swinton, John R., Ed.

    Volume II of a three-volume study on the future of the food service industry considers the effects that centralized food production will have on the future of food production systems. Based on information from the Fair Acres Project and the Michigan State University Vegetable Processing Center, the authors describe the operations of a centralized…

  11. Lightweight, Wearable Metal Rubber-Textile Sensor for In-Situ Lunar Autonomous Health Monitoring, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This NASA Phase II SBIR program would develop comfortable garments with multiple integrated sensor functions for the monitoring of astronauts during long duration...

  12. Airborne gamma-ray spectrometer and magnetometer survey: Monument Valley B, Utah, detail area. Volume II A. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II A contains appendices for: stacked profiles; geologic histograms; geochemical histograms; speed and altitude histograms; geologic statistical tables; geochemical statistical tables; magnetic and ancillary profiles; and test line data

  13. Airborne gamma-ray spectrometer and magnetometer survey: Monument Valley B, Utah, detail area. Volume II B. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II B contains appendices for: flight line maps; geology maps; explanation of geologic legend; flight line/geology maps; radiometric contour maps; magnetic contour maps; and geochemical factor analysis maps

  14. Complex-wide review of DOE's Low-Level Waste Management ES ampersand H vulnerabilities. Volume II. Final report

    International Nuclear Information System (INIS)

    1996-05-01

    Volume I of this report presents a summary of DOE's complex-wide review of its low-level waste management system, including the assessment scope and methodology, site-specific and complex-wide vulnerabilities, and DOE's conclusions and recommendations. Volume II presents a more detailed discussion of the assessment methodology and evaluation instruments developed by the Assessment Working Group for identifying site-specific vulnerabilities, categorizing and classifying vulnerabilities, and identifying and analyzing complex-wide vulnerabilities. Attachments A and B of this volume contain, respectively, the Site Evaluation Survey and the Vulnerability Assessment Form used in those processes. Volume III contains the site-specific assessment reports for the 36 sites (38 facilities) assessed in the complex-wide review from which the complex-wide vulnerabilities were drawn

  15. New York City Police Department Automated Fuel Monitoring System. Volume II. Documentation Report.

    Science.gov (United States)

    1981-11-16

    toward solving troublesome problems. In addition, the private sector market has been stimulated to respond to system needs identified during the course of...8 -3Q .ifL I.N’ p uii3NLIE- __-U3 7/11 Ud-.i T01 LNI TERM ON-LN 151 071 328- ______ 33N.________ -~R~ NLINE 2141 53 07/11 16-ttl 145 INS TERM ON-LINE...4Z-46 131 LN4 TERM NLINE --3o56a 55 O7ALL-ZU _1 L. N ~Ii8ILON-~ik 1559 53 01/17 eZ-4.8 137 INN TERM4 ON-LINE " . " - 7 - M -1 ------------- - . 7 .Dm

  16. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  17. Environmental contaminants in food. Volume II-Part B: Working papers

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Toxic substances in food information systems: design and management; (2) Assessment of carcinogenic risks from PCBs in food; (3) Economic analysis of alternative action levels in the regulation of environmental contaminants in food; (4) Analysis of foods for radioactivity; (5) Approaches to monitoring environmental contaminants in food; (6) Analytical systems for the determination of metals in food and water supplies; (7) Assessment of methods for regulating 'unavoidable' contaminants in the food supply; and (8) Consumer risk from environmental contaminants in food

  18. Personal, societal, and ecological values of wilderness: Sixth World Wilderness Congress proceedings on research, management, and allocation, Volume II

    Science.gov (United States)

    Alan E. Watson; Greg H. Aplet; John C. Hendee

    2000-01-01

    The papers contained in Volume II of these Proceedings represent a combination of papers originally scheduled for the delayed 1997 meeting of the World Wilderness Congress and those submitted in response to a second call for papers when the Congress was rescheduled for October 24-29, 1998, in Bangalore, India. Just as in Volume I, the papers are divided into seven...

  19. Airborne gamma-ray spectrometer and magnetometer survey: Monument Valley A, Utah, detail area. Volume II B. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    Volume II B contains appendices for: flight line maps; geology maps; explanation of geologic legend; flight line/geology maps; radiometric contour maps; magnetic contour maps; multi-variant analysis maps; and geochemical factor analysis maps

  20. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  1. Numerical simulation of the PEP-II beam position monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kurita, N; Martin, D; Ng, C -K; Smith, S [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Weiland, T

    1996-08-01

    We use MAFIA to analyze the PEP-II button-type beam position monitor (BPM). Employing proper termination of the BPM into a coaxial cable, the output signal at the BPM is determined. Thus the issues of signal sensitivity and power output can be addressed quantitatively, including all transient effects and wakefields. Besides this first quantitative analysis of a true BPM 3D structure, we find that internal resonant modes are a major source of high value narrow-band impedances. The effects of these resonances on coupled-bunch instabilities are discussed. An estimate of the power dissipation in the ceramic vacuum seal under high current operation is given. (author)

  2. Numerical simulation of the PEP-II beam position monitor

    International Nuclear Information System (INIS)

    Kurita, N.; Martin, D.; Ng, C.K.; Smith, S.; Weiland, T.

    1995-09-01

    The authors use MAFIA to analyze the PEP-II button-type beam position monitor (BPM). Employing proper termination of the BPM into a coaxial cable, the output signal at the BPM is determined. Thus the issues of signal sensitivity and power output can be addressed quantitatively, including all transient effects and wakefields. Besides this first quantitative analysis of a true BPM 3D structure, they find that internal resonant modes are a major-source of high value narrow-band impedances. The effects of these resonances on coupled-bunch instabilities are discussed. An estimate of the power dissipation in the ceramic vacuum seal under high current operation is given

  3. Annual report on radioactive discharges and monitoring of the environment 1992. V. 2

    International Nuclear Information System (INIS)

    1993-01-01

    This Annual Report supplements British Nuclear Fuel plc's Health and Safety Annual Report by providing more detailed information on radioactive discharges, monitoring of the environmental and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment, covering the period from 1977 to the present. For 1991 this report has been sub-divided into two complementary parts. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  4. Annual report on radioactive discharges and monitoring of the environment 1991. V. 2

    International Nuclear Information System (INIS)

    1992-01-01

    This Annual Report supplements British Nuclear Fuel plc's Health and Safety Annual Report by providing more detailed information on radioactive discharges, monitoring of the environmental and critical group doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment, covering the period from 1977 to the present. For 1991 this report has been sub-divided into two complementary parts. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  5. Open-access MIMIC-II database for intensive care research.

    Science.gov (United States)

    Lee, Joon; Scott, Daniel J; Villarroel, Mauricio; Clifford, Gari D; Saeed, Mohammed; Mark, Roger G

    2011-01-01

    The critical state of intensive care unit (ICU) patients demands close monitoring, and as a result a large volume of multi-parameter data is collected continuously. This represents a unique opportunity for researchers interested in clinical data mining. We sought to foster a more transparent and efficient intensive care research community by building a publicly available ICU database, namely Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II). The data harnessed in MIMIC-II were collected from the ICUs of Beth Israel Deaconess Medical Center from 2001 to 2008 and represent 26,870 adult hospital admissions (version 2.6). MIMIC-II consists of two major components: clinical data and physiological waveforms. The clinical data, which include patient demographics, intravenous medication drip rates, and laboratory test results, were organized into a relational database. The physiological waveforms, including 125 Hz signals recorded at bedside and corresponding vital signs, were stored in an open-source format. MIMIC-II data were also deidentified in order to remove protected health information. Any interested researcher can gain access to MIMIC-II free of charge after signing a data use agreement and completing human subjects training. MIMIC-II can support a wide variety of research studies, ranging from the development of clinical decision support algorithms to retrospective clinical studies. We anticipate that MIMIC-II will be an invaluable resource for intensive care research by stimulating fair comparisons among different studies.

  6. Site environmental report for 2000. Volume I, Environment, Health and Safety Division

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Robert [Environmental Services Group, Berkeley, CA (US); Javandel, Iraj [Environmental Services Group, Berkeley, CA (US); Lackner, Ginny [Environmental Services Group, Berkeley, CA (US); Ruggieri, Michael [Environmental Services Group, Berkeley, CA (US); Thorson, Patrick [Environmental Services Group, Berkeley, CA (US); Wahl, Linnea [Environmental Services Group, Berkeley, CA (US)

    2001-09-30

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab) prepared an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The Site Environmental Report for 2000 is intended to summarize Berkeley Lab's compliance with environmental standards and requirements, characterize environmental management efforts through surveillance and monitoring activities, and highlight significant programs and efforts for calendar year 2000. Laboratory, the status of environmental programs, and summary results from surveillance and monitoring activities. Each chapter in Volume I begins with an outline of the sections that follow, including any tables or figures found in the chapter. Readers should use section numbers (e.g., §1.5) as navigational tools to find topics of interest in either the printed or the electronic version of the report. Volume II contains the individual data results from monitoring programs. Although a printed version of Volume II is not part of the report's initial distribution, it is available on request (see below). The report follows the Laboratory's policy of using the International System of Units (SI) or metric system of measurements. Whenever possible, results are also reported using the more conventional inch-pound system of measurements because this system is referenced by some current regulatory standards and may be more familiar to some readers. The tables included at the end of the Glossary are intended to help readers understand the various prefixes used with SI units of measurement and convert these units from one system to the other.

  7. SLIM-MAUD: an approach to assessing human error probabilities using structured expert judgment. Volume II. Detailed analysis of the technical issues

    International Nuclear Information System (INIS)

    Embrey, D.E.; Humphreys, P.; Rosa, E.A.; Kirwan, B.; Rea, K.

    1984-07-01

    This two-volume report presents the procedures and analyses performed in developing an approach for structuring expert judgments to estimate human error probabilities. Volume I presents an overview of work performed in developing the approach: SLIM-MAUD (Success Likelihood Index Methodology, implemented through the use of an interactive computer program called MAUD-Multi-Attribute Utility Decomposition). Volume II provides a more detailed analysis of the technical issues underlying the approach

  8. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 3: Specifications

    International Nuclear Information System (INIS)

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 3 is a compilation of the construction specifications that will constitute the Title II materials and performance specifications. This volume contains CSI specifications for non-equipment related construction material type items, performance type items, and facility mechanical equipment items. Data sheets are provided, as necessary, which specify the equipment overall design parameters

  9. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 3: Specifications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 3 is a compilation of the construction specifications that will constitute the Title II materials and performance specifications. This volume contains CSI specifications for non-equipment related construction material type items, performance type items, and facility mechanical equipment items. Data sheets are provided, as necessary, which specify the equipment overall design parameters.

  10. Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes

    Science.gov (United States)

    Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.

    2016-07-01

    Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50-100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering.

  11. Annual report on radioactive discharges and monitoring of the environment 1990. V. 2

    International Nuclear Information System (INIS)

    1991-01-01

    This Annual Report supplements the Health and Safety Annual Report of British Nuclear Fuels plc by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. This report has been sub-divided into two complementary parts. Volume I includes annual data for each of the Company sites on radioactive discharges into the environment and the associated environmental monitoring programmes. The sites involved are: Sellafield where the main activities are irradiated nuclear fuel reprocessing and the Calder Hall nuclear station; the Drigg radioactive waste storage and disposal site; the Chapelcross nuclear power station; Springfields Works which manufactures nuclear fuels; Capenhurst Works where uranium isotopic enrichment plants are operated. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  12. Annual report on radioactive discharges and monitoring of the environment 1990. V. 1

    International Nuclear Information System (INIS)

    1991-01-01

    This Annual Report supplements the Health and Safety Annual Report of British Nuclear Fuels plc by providing more detailed information on radioactive discharges, monitoring of the environment and critical group doses. This report has been sub-divided into two complementary parts. Volume I includes annual data for each of the Company sites on radioactive discharges into the environment and the associated environmental monitoring programmes. The sites involved are: Sellafield where the main activities are irradiated nuclear fuel reprocessing and the Calder Hall nuclear station; the Drigg radioactive waste storage and disposal site; the Chapelcross nuclear power station; Springfields Works which manufactures nuclear fuels; Capenhurst Works where uranium isotopic enrichment plants are operated. Volume II reproduces the Certificates of Authorisation under which the Company operates and the statutory environmental monitoring programmes which relate to them. (author)

  13. Three Mile Island: a report to the commissioners and to the public. Volume II, Part 1

    International Nuclear Information System (INIS)

    1979-01-01

    This is part one of three parts of the second volume of the Special Inquiry Group's report to the Nuclear Regulatory Commission on the accident at Three Mile Island. The first volume contained a narrative description of the accident and a discussion of the major conclusions and recommendations. This second volume is divided into three parts. Part 1 of Volume II focuses on the pre-accident licensing and regulatory background. This part includes an examination of the overall licensing and regulatory system for nuclear powerplants viewed from different perspectives: the system as it is set forth in statutes and regulations, as described in Congressional testimony, and an overview of the system as it really works. In addition, Part 1 includes the licensing, operating, and inspection history of Three Mile Island Unit 2, discussions of relevant regulatory matters, a discussion of specific precursor events related to the accident, a case study of the pressurizer design issue, and an analysis of incentives to declare commercial operation

  14. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  15. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  16. Accuracy of near-patient vs. inbuilt spirometry for monitoring tidal volumes in an in-vitro paediatric lung model.

    Science.gov (United States)

    Morgenroth, S; Thomas, J; Cannizzaro, V; Weiss, M; Schmidt, A R

    2018-03-01

    Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS 2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS 2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients. © 2018 The Association of Anaesthetists of Great Britain and Ireland.

  17. Limitations and challenges of EIT-based monitoring of stroke volume and pulmonary artery pressure.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Lemay, Mathieu; Bertschi, Mattia; Adler, Andy; Thiran, Jean-Philippe; Solà, Josep

    2018-01-30

    Electrical impedance tomography (EIT) shows potential for radiation-free and noninvasive hemodynamic monitoring. However, many factors degrade the accuracy and repeatability of these measurements. Our goal is to estimate the impact of this variability on the EIT-based monitoring of two important central hemodynamic parameters: stroke volume (SV) and pulmonary artery pressure (PAP). We performed simulations on a 4D ([Formula: see text]) bioimpedance model of a human volunteer to study the influence of four potential confounding factors (electrode belt displacement, electrode detachment, changes in hematocrit and lung air volume) on the performance of EIT-based SV and PAP estimation. Results were used to estimate how these factors affect the EIT measures of either absolute values or relative changes (i.e. trending). Our findings reveal that the absolute measurement of SV via EIT is very sensitive to electrode belt displacements and lung conductivity changes. Nonetheless, the trending ability of SV EIT might be a promising alternative. The timing-based measurement of PAP is more robust to lung conductivity changes but sensitive to longitudinal belt displacements at severe hypertensive levels and to rotational displacements (independent of the PAP level). We identify and quantify the challenges of EIT-based SV and PAP monitoring. Absolute SV via EIT is challenging, but trending is feasible, while both the absolute and trending of PAP via EIT are mostly impaired by belt displacements.

  18. Monitoring complex detectors: the uSOP approach in the Belle II experiment

    International Nuclear Information System (INIS)

    Capua, F. Di; Aloisio, A.; Giordano, R.; Ameli, F.; Anastasio, A.; Izzo, V.; Tortone, G.; Branchini, P.

    2017-01-01

    uSOP is a general purpose single board computer designed for deep embedded applications in control and monitoring of detectors, sensors and complex laboratory equipments. It is based on the AM3358 (1 GHz ARM Cortex A8 processor), equipped with USB and Ethernet interfaces. On-board RAM and solid state storage allows hosting a full LINUX distribution. In this paper we discuss the main aspects of the hardware and software design and the expandable peripheral architecture built around field busses. We report on several applications of uSOP system in the Belle II experiment, presently under construction at KEK (Tsukuba, Japan). In particular we will report the deployment of uSOP in the monitoring system framework of the endcap electromagnetic calorimeter.

  19. Monitoring complex detectors: the uSOP approach in the Belle II experiment

    Science.gov (United States)

    Di Capua, F.; Aloisio, A.; Ameli, F.; Anastasio, A.; Branchini, P.; Giordano, R.; Izzo, V.; Tortone, G.

    2017-08-01

    uSOP is a general purpose single board computer designed for deep embedded applications in control and monitoring of detectors, sensors and complex laboratory equipments. It is based on the AM3358 (1 GHz ARM Cortex A8 processor), equipped with USB and Ethernet interfaces. On-board RAM and solid state storage allows hosting a full LINUX distribution. In this paper we discuss the main aspects of the hardware and software design and the expandable peripheral architecture built around field busses. We report on several applications of uSOP system in the Belle II experiment, presently under construction at KEK (Tsukuba, Japan). In particular we will report the deployment of uSOP in the monitoring system framework of the endcap electromagnetic calorimeter.

  20. ICPP calcined solids storage facility closure study. Volume II: Cost estimates, planning schedules, yearly cost flowcharts, and life-cycle cost estimates

    International Nuclear Information System (INIS)

    1998-02-01

    This document contains Volume II of the Closure Study for the Idaho Chemical Processing Plant Calcined Solids Storage Facility. This volume contains draft information on cost estimates, planning schedules, yearly cost flowcharts, and life-cycle costs for the four options described in Volume I: (1) Risk-Based Clean Closure; NRC Class C fill, (2) Risk-Based Clean Closure; Clean fill, (3) Closure to landfill Standards; NRC Class C fill, and (4) Closure to Landfill Standards; Clean fill

  1. ICPP calcined solids storage facility closure study. Volume II: Cost estimates, planning schedules, yearly cost flowcharts, and life-cycle cost estimates

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This document contains Volume II of the Closure Study for the Idaho Chemical Processing Plant Calcined Solids Storage Facility. This volume contains draft information on cost estimates, planning schedules, yearly cost flowcharts, and life-cycle costs for the four options described in Volume I: (1) Risk-Based Clean Closure; NRC Class C fill, (2) Risk-Based Clean Closure; Clean fill, (3) Closure to landfill Standards; NRC Class C fill, and (4) Closure to Landfill Standards; Clean fill.

  2. The repeatability of left ventricular volume assessment by a new ambulatory radionuclide monitoring system during head-up tilt

    International Nuclear Information System (INIS)

    Takase, Bonpei; Hosaka, Haruhiko; Kitamura, Katsuhiro

    2001-01-01

    The precise measurement of changes in left ventricular volume is important to elucidate the mechanisms of neurally mediated syncope. This study was conducted to determine whether or not a brand-new ambulatory radionuclide monitoring system (C-VEST system) can be clinically used to easily and precisely measure left ventricular volume and function in tilt testing. To assess the repeatability of the C-VEST system, 12 healthy volunteers (mean age 24±4 years old) underwent 20 minute head-up tilt testing and we measured the temporal changes in left ventricular volume and ejection fraction twice a day (first and second studies). To investigate the changes in the C-VEST measurements and the detector position in the first and second studies, tilt testing was performed with an 80-degree passive tilt, which is the same as the standard procedure used in diagnosing neurally mediated syncope. The coefficient of repeatability for both the C-VEST and detector position was well within the clinical range (coefficient of repeatability in left ventricular volume ranged from 1.7 to 2.8; coefficient of repeatability in the detector position ranged from 2.3 to 3.1). Precise evaluation of the left ventricular volume can be achieved by an ambulatory radionuclide monitoring system in tilt testing. (author)

  3. Sodium fast reactor safety and licensing research plan - Volume II

    International Nuclear Information System (INIS)

    Ludewig, H.; Powers, D.A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A.; Phillips, J.; Zeyen, R.; Clement, B.; Garner, Frank; Walters, Leon; Wright, Steve; Ott, Larry J.; Suo-Anttila, Ahti Jorma; Denning, Richard; Ohshima, Hiroyuki; Ohno, S.; Miyhara, S.; Yacout, Abdellatif; Farmer, M.; Wade, D.; Grandy, C.; Schmidt, R.; Cahalen, J.; Olivier, Tara Jean; Budnitz, R.; Tobita, Yoshiharu; Serre, Frederic; Natesan, Ken; Carbajo, Juan J.; Jeong, Hae-Yong; Wigeland, Roald; Corradini, Michael; Thomas, Justin; Wei, Tom; Sofu, Tanju; Flanagan, George F.; Bari, R.; Porter D.

    2012-01-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  4. Sodium fast reactor safety and licensing research plan. Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, H. (Brokhaven National Laboratory, Upton, NY); Powers, D. A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A. (Argonne National Laboratory, Argonne, IL); Phillips, J.; Zeyen, R. (Institute for Energy Petten, Saint-Paul-lez-Durance, France); Clement, B. (IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France); Garner, Frank (Radiation Effects Consulting, Richland, WA); Walters, Leon (Advanced Reactor Concepts, Los Alamos, NM); Wright, Steve; Ott, Larry J. (Oak Ridge National Laboratory, Oak Ridge, TN); Suo-Anttila, Ahti Jorma; Denning, Richard (Ohio State University, Columbus, OH); Ohshima, Hiroyuki (Japan Atomic Energy Agency, Ibaraki, Japan); Ohno, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Miyhara, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Yacout, Abdellatif (Argonne National Laboratory, Argonne, IL); Farmer, M. (Argonne National Laboratory, Argonne, IL); Wade, D. (Argonne National Laboratory, Argonne, IL); Grandy, C. (Argonne National Laboratory, Argonne, IL); Schmidt, R.; Cahalen, J. (Argonne National Laboratory, Argonne, IL); Olivier, Tara Jean; Budnitz, R. (Lawrence Berkeley National Laboratory, Berkeley, CA); Tobita, Yoshiharu (Japan Atomic Energy Agency, Ibaraki, Japan); Serre, Frederic (Centre d' %C3%94etudes nucl%C3%94eaires de Cadarache, Cea, France); Natesan, Ken (Argonne National Laboratory, Argonne, IL); Carbajo, Juan J. (Oak Ridge National Laboratory, Oak Ridge, TN); Jeong, Hae-Yong (Korea Atomic Energy Research Institute, Daejeon, Korea); Wigeland, Roald (Idaho National Laboratory, Idaho Falls, ID); Corradini, Michael (University of Wisconsin-Madison, Madison, WI); Thomas, Justin (Argonne National Laboratory, Argonne, IL); Wei, Tom (Argonne National Laboratory, Argonne, IL); Sofu, Tanju (Argonne National Laboratory, Argonne, IL); Flanagan, George F. (Oak Ridge National Laboratory, Oak Ridge, TN); Bari, R. (Brokhaven National Laboratory, Upton, NY); Porter D. (Idaho National Laboratory, Idaho Falls, ID); Lambert, J. (Argonne National Laboratory, Argonne, IL); Hayes, S. (Idaho National Laboratory, Idaho Falls, ID); Sackett, J. (Idaho National Laboratory, Idaho Falls, ID); Denman, Matthew R.

    2012-05-01

    Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

  5. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  6. Design and evaluation of potentiometric principles for bladder volume monitoring: a preliminary study.

    Science.gov (United States)

    Chen, Shih-Ching; Hsieh, Tsung-Hsun; Fan, Wen-Jia; Lai, Chien-Hung; Chen, Chun-Lung; Wei, Wei-Feng; Peng, Chih-Wei

    2015-06-01

    Recent advances in microelectronics and wireless transmission technology have led to the development of various implantable sensors for real-time monitoring of bladder conditions. Although various sensing approaches for monitoring bladder conditions were reported, most such sensors have remained at the laboratory stage due to the existence of vital drawbacks. In the present study, we explored a new concept for monitoring the bladder capacity on the basis of potentiometric principles. A prototype of a potentiometer module was designed and fabricated and integrated with a commercial wireless transmission module and power unit. A series of in vitro pig bladder experiments was conducted to determine the best design parameters for implementing the prototype potentiometric device and to prove its feasibility. We successfully implemented the potentiometric module in a pig bladder model in vitro, and the error of the accuracy of bladder volume detection was design principles and animal experience gathered from this research can serve as a basis for developing new implantable bladder sensors in the future.

  7. Study of the Utah uranium-milling industry. Volume I. A policy analysis

    International Nuclear Information System (INIS)

    Turley, R.E.

    1980-05-01

    This is the first volume of a two volume study of the Utah Uranium Milling Industry. The study was precipitated by a 1977 report issued by the Western Interstate Nuclear Board entitled Policy Recommendations on Financing Stabilization. Perpetual Surveillance and Maintenance of Uranium Mill Tailings. Volume I of this study is a policy analysis or technology assessment of the uranium milling industry in the state of Utah; specifically, the study addresses issues that deal with the perpetual surveillance, monitoring, and maintenance of uranium tailings piles at the end of uranium milling operations, i.e., following shutdown and decommissioning. Volume II of this report serves somewhat as an appendix. It represents a full description of the uranium industry in the state of Utah, including its history and statements regarding its future. The topics covered in volume I are as follows: today's uranium industry in Utah; management of the industry's characteristic nuclear radiation; uranium mill licensing and regulation; state licensing and regulation of uranium mills; forecast of future milling operations; policy needs relative to perpetual surveillance, monitoring, and maintenance of tailings; policy needs relative to perpetual oversight; economic aspects; state revenue from uranium; and summary with conclusions and recommendations. Appendices, figures and tables are also presented

  8. Ocean Thermal Energy Converstion (OTEC) test facilities study program. Final report. Volume II. Part B

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-17

    Results are presented of an 8-month study to develop alternative non-site-specific OTEC facilities/platform requirements for an integrated OTEC test program which may include land and floating test facilities. Volume II--Appendixes is bound in three parts (A, B, and C) which together comprise a compendium of the most significant detailed data developed during the study. Part B provides an annotated test list and describes component tests and system tests.

  9. Assessment of gold flux monitor at irradiation facilities of MINT TRIGA MK II reactor

    International Nuclear Information System (INIS)

    Wee Boon Siong; Abdul Khalik Wood; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman; Md Suhaimi Elias; Nazaratul Ashifa Abd Salim

    2005-01-01

    Neutron source of MINTs TRIGA MK II reactor has been used for activation analysis for many years and neutron flux plays important role in activation of samples at various positions. Currently, two irradiation facilities namely the pneumatic transfer system and rotary rack are available to cater for short and long lived irradiation. Neutron flux variation for both irradiation facilities have been determined using gold wire and gold solution as flux monitor. However, the use of gold wire as flux monitor is costlier if compared to gold solution. The results from analysis of certified reference materials showed that gold solution as flux monitors yield satisfactory results and proved to safe cost on the purchasing of gold wire. Further experiment on self-shielding effects of gold solution at various concentrations has been carried out. This study is crucial in providing vital information on the suitable concentration for gold solution as flux monitor. In the near future, gold solution flux monitor will be applied for routine analysis and hence to improve the capability of the laboratory on neutron activation analysis. (Author)

  10. Structure-volume relationships: singular volume effects produced by cupric ion-globular protein interaction.

    Science.gov (United States)

    Katz, S; Shinaberry, G; Heck, E L; Squire, W

    1980-08-05

    The nature of the volume isotherms produced by the coordination of Cu(II) with ovalbumin and bovine serum albumin differs substantially from the adsorption isotherms produced by these systems. Whereas there was increased binding of Cu(II) associated with a pH increase from pH 5.3 to pH 7.4, the volume isotherms for these systems did not exhibit this type of pH dependence. The volume changes were determined at 30.0 +/- 0.001 degrees C with microdilatometers which could be read to 0.01 muL. The binding isotherms for ovalbumin at pH 5.3 and 7.4 and for bovine serum albumin at pH 5.3 was resolved by a Scatchard plot to yield the appropriate thermodynamic parameters. An algorithm was derived to calculate the distribution of the individual PMi complexes, i.e., PMi-1 + M in equilibrium (Ki) PMi where i equals 1, 2, 3, ..., n moles of cation, M, bound per mole of protein, P, for the above systems. The volume isotherms were then resolved in terms of the constituent delta Vi terms, i.e., the volume change produced by the formation of the individual PMi complexes. These values were verified by an independent graphical differentiation procedure. The coordination of Cu(II) to BSA at pH 7.4 produced a cooperative adsorption isotherm which was not amenable to a Scatchard analysis. The resultant anomalous volume isotherm was resolved into a component related to Cu(II)-site interaction and a negative volume effect attributable to a conformational change induced by complex formation. This structural transition which occurs at physiological pH may constitute a control mechanism for regulating the serum level of Cu(II) and possibly other divalent ions.

  11. PISC II: Parametric studies. Monitoring of PISC-II parametric studies in ultrasonic NDT for PWR

    International Nuclear Information System (INIS)

    Toft, M.W.

    1989-09-01

    The CEGB NDT Applications Centre is partipating in the EEC-funded international Programme for the Inspection of Steel Components (PISC) on account of its relevance to the inspection of Sizewell B and future PWRs. This report describes an inspection monitoring exercise undertaken by NDTAC under partial funding from JRC Ispra, at the initiation of the PISC-III Ultrasonic Modelling Group. Experimental studies have been carried out under PISC-II to investigate ultrasonic defect response as a function of various parameters which characterise the inspection situation. Some of these parametric studies are potentially useful for the validation of theoretical models of ultrasonic inspection and are consequently relevant to the work of the PISC-III Modelling Group. The aim of the present exercise was to ensure that data obtained by the various contract organizations participating in the PISC-II Parametric Studies was of high quality, was a complete record of the inspection and would yield valid comparisons with the predictions of theoretical models. The exercise entailed visits by a nominated CEGB observer to 4 European NDT Laboratories at which the parametric studies were in progress; CISE (Milan); UKAEA (Harwell); UKAEA (Risley) and Vincotte (Brussels). This report presents the findings of those visits

  12. Ground-water monitoring compliance projects for Hanford Site Facilities: Progress report for the period April 1--June 30, 1988: Volume 1, Text

    International Nuclear Information System (INIS)

    1988-09-01

    This is Volume 1 of a two-volume set of documents that describes the progress of 10 Hanford Site ground-water monitoring projects for the period April 1 to June 30, 1988. This volume discusses the projects; Volume 2 provides as-built diagrams, drilling logs, and geophysical logs for wells drilled during this period in the 100-N Area and near the 216-A-36B Crib

  13. Fukushima Daiichi Unit 1 Uncertainty Analysis-Exploration of Core Melt Progression Uncertain Parameters-Volume II.

    Energy Technology Data Exchange (ETDEWEB)

    Denman, Matthew R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    Sandia National Laboratories (SNL) has conducted an uncertainty analysi s (UA) on the Fukushima Daiichi unit (1F1) accident progression wit h the MELCOR code. Volume I of the 1F1 UA discusses the physical modeling details and time history results of the UA. Volume II of the 1F1 UA discusses the statistical viewpoint. The model used was developed for a previous accident reconstruction investigation jointly sponsored by the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC). The goal of this work was to perform a focused evaluation of uncertainty in core damage progression behavior and its effect on key figures - of - merit (e.g., hydrogen production, fraction of intact fuel, vessel lower head failure) and in doing so assess the applicability of traditional sensitivity analysis techniques .

  14. The Argonne Radiological Impact Program (ARIP). Part II. MONITOR: A Program and Data Base for Retrieval and Utilization of Pollutant Monitoring Data

    Energy Technology Data Exchange (ETDEWEB)

    Eckerman, Keith F.; Stowe, Ralph F.; Frigerio, Norman A.

    1977-02-01

    The Argonne Radiological Impact Program (ARIP) is an ongoing project of the Laboratory's Division of Environmental Impact Studies that aims at developing methodologies for assessing the carcinogenic hazards associated with nuclear power development. The project's first report (ANL/ES-26, Part I), published in September.l973, discussed models of radiation carcinogenesis and the contribution of U .. S. background radiation levels to hazardous dose rates. The current report (Part II) treats the storage and access of available data on radiation and radioactivity levels in the u. S. A compute-r code. (the MONITOR program) is prf!sented, which can serve as a ready-access data. bank for all monitoring data acquired over the past two decades. The MONITOR program currently stores data on monitoring locations, types of monitoring efforts, and types of monitoring data. reported in Radiation Data and Reports by the various state and federal ne-tworks; expansion of this data base to include nuclear power facilities in operation or on order is ongoing ·. The MONITOR code retrieves information within a search radius, or rectangl.e ,. circumscribed by parameters of latitude and longitude, and l:.ists or maps the data_as: requested. The code, with examples, is given in full in the report ..

  15. Assessment and management of ageing of major nuclear power plant components important to safety: In-containment instrumentation and control cables. Volume II

    International Nuclear Information System (INIS)

    2000-12-01

    and technical support organizations dealing with specific plant components addressed in the reports. The component addressed in the present report is the in-containment instrumentation and control (I and C) cables. The report presents, in two volumes, results of a Co-ordinated Research Project (CRP) on the Management of Ageing of In-containment Instrumentation and Control cables. Part I, Volume 1 presents information on current methods for assessing and managing ageing degradation of Instrumentation and Control cables in real NPP environments prepared by the CRP team. An important complement of this information is user perspectives on the application of these methods which are presented in Part II, Volume 1. Volume 2 contains annexes supporting the guidance of Volume 1 with more detailed information and examples provided by individual CRP participants. For a quick overview, readers should see Section 8 of Part I, Volume 1, which describes a systematic ageing management programme for Instrumentation and Control cables utilizing methods presented in the report; Section 9 of Part I, Volume 1, which presents CRP conclusions and recommendations; and Part II providing the application guidance from the user's perspective

  16. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 1: Title II design report

    International Nuclear Information System (INIS)

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 1 provides a comprehensive narrative description of the proposed facility and systems, the basis for each of the systems design, and the engineering assessments that were performed to support the technical basis of the Title II design. The intent of the system description presented is to provide WHC an understanding of the facilities and equipment provided and the A/E's perspective on how these systems will operate

  17. IGF-II transgenic mice display increased aberrant colon crypt multiplicity and tumor volume after 1,2-dimethylhydrazine treatment

    Directory of Open Access Journals (Sweden)

    Oesterle Doris

    2006-01-01

    Full Text Available Abstract In colorectal cancer insulin-like growth factor II (IGF-II is frequently overexpressed. To evaluate, whether IGF-II affects different stages of tumorigenesis, we induced neoplastic alterations in the colon of wild-type and IGF-II transgenic mice using 1,2-dimethylhydrazine (DMH. Aberrant crypt foci (ACF served as markers of early lesions in the colonic mucosa, whereas adenomas and carcinomas characterized the endpoints of tumor development. DMH-treatment led initially to significantly more ACF in IGF-II transgenic than in wild-type mice. This increase in ACF was especially prominent for those consisting of ≥three aberrant crypts (AC. Nevertheless, adenomas and adenocarcinomas of the colon, present after 34 weeks in both genetic groups, were not found at different frequency. Tumor volumes, however, were significantly higher in IGF-II transgenic mice and correlated with serum IGF-II levels. Immunohistochemical staining for markers of proliferation and apoptosis revealed increased cell proliferation rates in tumors of IGF-II transgenic mice without significant affection of apoptosis. Increased proliferation was accompanied by elevated localization of β-catenin in the cytosol and cell nuclei and reduced appearance at the inner plasma membrane. In conclusion, we provide evidence that IGF-II, via activation of the β-catenin signaling cascade, promotes growth of ACF and tumors without affecting tumor numbers.

  18. Run II performance of luminosity and beam condition monitors at CMS

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jessica Lynn [DESY, Hamburg (Germany)

    2016-07-01

    The BRIL (Beam Radiation Instrumentation and Luminosity) system of CMS consists of instrumentation to measure the luminosity online and offline, and to monitor the LHC beam conditions inside CMS. An accurate luminosity measurement is essential to the CMS physics program, and measurement of the beam background is necessary to ensure safe operation of CMS. Many of the BRIL subsystems have been upgraded and others have been added for LHC Run II to complement the existing measurements. The beam condition monitor (BCM) consists of several sets of diamond sensors used to measure online luminosity and beam background with a single-bunch-crossing resolution. The BCM also detects when beam conditions become unfavorable for CMS running and may trigger a beam abort to protect the detector. The beam halo monitor (BHM) uses quartz bars to measure the background of the incoming beams at larger radii. The pixel luminosity telescope (PLT) consists of telescopes of silicon sensors designed to provide a CMS online and offline luminosity measurement. In addition, the forward hadronic calorimeter (HF) delivers an independent luminosity measurement, making the whole system robust and allowing for cross-checks of the systematics. An overview of the performance during 2015 LHC running for the new/updated BRIL subsystems will be given, including the uncertainties of the luminosity measurements.

  19. Life system modeling and intelligent computing. Pt. II. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Li, Kang; Irwin, George W. (eds.) [Belfast Queen' s Univ. (United Kingdom). School of Electronics, Electrical Engineering and Computer Science; Fei, Minrui; Jia, Li [Shanghai Univ. (China). School of Mechatronical Engineering and Automation

    2010-07-01

    This book is part II of a two-volume work that contains the refereed proceedings of the International Conference on Life System Modeling and Simulation, LSMS 2010 and the International Conference on Intelligent Computing for Sustainable Energy and Environment, ICSEE 2010, held in Wuxi, China, in September 2010. The 194 revised full papers presented were carefully reviewed and selected from over 880 submissions and recommended for publication by Springer in two volumes of Lecture Notes in Computer Science (LNCS) and one volume of Lecture Notes in Bioinformatics (LNBI). This particular volume of Lecture Notes in Computer Science (LNCS) includes 55 papers covering 7 relevant topics. The 56 papers in this volume are organized in topical sections on advanced evolutionary computing theory and algorithms; advanced neural network and fuzzy system theory and algorithms; modeling and simulation of societies and collective behavior; biomedical signal processing, imaging, and visualization; intelligent computing and control in distributed power generation systems; intelligent methods in power and energy infrastructure development; intelligent modeling, monitoring, and control of complex nonlinear systems. (orig.)

  20. II-VI semiconductor compounds

    CERN Document Server

    1993-01-01

    For condensed matter physicists and electronic engineers, this volume deals with aspects of II-VI semiconductor compounds. Areas covered include devices and applications of II-VI compounds; Co-based II-IV semi-magnetic semiconductors; and electronic structure of strained II-VI superlattices.

  1. Aerial radiometric and magnetic survey; Brushy Basin detail survey: Price/Salina national topographic map sheets, Utah. Volume III. Area II: graphic data, Section I-II. Final report

    International Nuclear Information System (INIS)

    1981-01-01

    This volume contains all of the graphic data for Area II which consists of map lines 1660 to 3400 and 5360 to 5780, and tie lines 6100, 6120, and 6160. Due to the large map scale of the presented data (1:62,500), this sub-section was divided into eleven 7-1/2 min quadrant sheets

  2. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    Science.gov (United States)

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  3. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    African Journal of Economic Review, Volume 1I, Issue 2, July 2014 ..... This paper also carries out the Chow-break point test (stability test) to test .... Unlike other East African countries, Rwanda has had a lot of political instabilities characterized.

  4. Preliminary evaluation of alternative waste form solidification processes. Volume II. Evaluation of the processes

    International Nuclear Information System (INIS)

    1980-08-01

    This Volume II presents engineering feasibility evaluations of the eleven processes for solidification of nuclear high-level liquid wastes (HHLW) described in Volume I of this report. Each evaluation was based in a systematic assessment of the process in respect to six principal evaluation criteria: complexity of process; state of development; safety; process requirements; development work required; and facility requirements. The principal criteria were further subdivided into a total of 22 subcriteria, each of which was assigned a weight. Each process was then assigned a figure of merit, on a scale of 1 to 10, for each of the subcriteria. A total rating was obtained for each process by summing the products of the subcriteria ratings and the subcriteria weights. The evaluations were based on the process descriptions presented in Volume I of this report, supplemented by information obtained from the literature, including publications by the originators of the various processes. Waste form properties were, in general, not evaluated. This document describes the approach which was taken, the developent and application of the rating criteria and subcriteria, and the evaluation results. A series of appendices set forth summary descriptions of the processes and the ratings, together with the complete numerical ratings assigned; two appendices present further technical details on the rating process

  5. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  6. Calibration of the beam-position monitor system for the SLAC PEP-II B factory

    International Nuclear Information System (INIS)

    Johnson, R.; Smith, S.; Kurita, N.

    1997-06-01

    The Beam-Position Monitors (BPM) for the PEP-II B Factory consist of four 1.5-cm diameter button style pickups mounted on the diagonals of the quadrupole vacuum chambers. Before installation of the vacuum chambers in the quadrupole assemblies, the electrical center of the BPMs is measured with respect to the mechanical center in a calibration test stand. In this paper the calibration test stand is described and the precision and accuracy of the calibrations are presented. After installation of the quadrupole assemblies in the PEP-II tunnel, the passive attenuation for each channel of the system is measured to preserve the accuracy of the calibration. Finally, the active electronics includes an onboard calibrator. Results for these portions of the calibration are presented

  7. Optimization of simultaneous electrochemical determination of Cd(II), Pb(II), Cu(II) and Hg(II) at carbon nanotube-modified graphite electrodes.

    Science.gov (United States)

    Pikna, L'ubomír; Heželová, Mária; Kováčová, Zuzana

    2015-01-01

    The health of the environment is worsening every day. Monitoring of potentially toxic elements and remediation of environmental pollution are necessary. Therefore, the research and development of simple, inexpensive, portable and effective sensors is important. Electrochemistry is a useful component of the field of environment monitoring. The present study focuses on evaluating and comparing three types of electrodes (PIGE, PIGE/MWCNT/HNO3 and PIGE/MWCNT/EDTA/HNO3) employed for the simultaneous electrochemical determination of four potentially toxic elements: Cd(II), Pb(II), Cu(II) and Hg(II). Cyclic voltammograms were measured in an acetate buffer. The LOD, LOQ, the standard and relative precisions of the method and a prediction intervals were calculated (according to the technical procedure DIN 32 645) for the three electrodes and for each measured element. The LOD for PIGE/CNT/HNO3 (the electrode with narrowest calculated prediction intervals) was 2.98 × 10(-7) mol L(-1) for Cd(II), 4.83 × 10(-7) mol L(-1) for Pb(II), 3.81 × 10(-7) mol L(-1) for Cu(II), 6.79 × 10(-7) mol L(-1) for Hg(II). One of the benefits of this study was the determination of the amount of Hg(II) in the mixture of other elements.

  8. Site Environmental Report for 2004. Volume 1, Environment, Health, and Safety Division

    Energy Technology Data Exchange (ETDEWEB)

    None

    2005-09-30

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2004 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2004. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as “Berkeley Lab,” “the Laboratory,” “Lawrence Berkeley National Laboratory,” and “LBNL.”) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from these activities. This year, the Site Environmental Report was distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request.

  9. The Department of Energy`s Rocky Flats Plant: A guide to record series useful for health-related research. Volume I, introduction

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    This guide consists of seven volumes which describe records useful for conducting health-related research at the DOE`s Rocky Flats Plant. Volume I is an introduction, and the remaining six volumes are arranged by the following categories: administrative and general, facilities and equipment, production and materials handling, waste management, workplace and environmental monitoring, and employee occupational exposure and health. Volume I briefly describes the Epidemiologic Records Project and provides information on the methodology used to inventory and describe the records series contained in subsequent volumes. Volume II describes records concerning administrative functions and general information. Volume III describes records series relating to the construction and routine maintenance of plant buildings and the purchase and installation of equipment. Volume IV describes records pertaining to the inventory and production of nuclear materials and weapon components. Records series include materials inventories, manufacturing specifications, engineering orders, transfer and shipment records, and War Reserve Bomb Books. Volume V describes records series pertaining to the storage, handling, treatment, and disposal of radioactive, chemical, or mixed materials produced or used at Rocky Flats. Volume VI describes records series pertaining to monitoring of the workplace and of the environment outside of buildings onsite and offsite. Volume VII describes records series pertaining to the health and occupational exposures of employees and visitors.

  10. Final report of the Multiprogram Laboratory Panel Energy Research Advisory Board. Volume II. Support studies

    International Nuclear Information System (INIS)

    Spiewak, I.; Guthrie, M.P.; Nichols, J.P.; Preston, E.L.; West, C.D.; Wilbanks, T.J.; Wilkes, B.Y.; Zerby, A.C.

    1982-09-01

    Volume II - support studies for nine national laboratories include: report of statistical data on the multiprogram laboratories; examples of national laboratory use in foreign countries; domestic models for national laboratory utilization; relationships of laboratories with industry and universities; uses of laboratories for training industrial R and D personnel; legal mandates and constraints on the national laboratories; with appendices on facts about Harwell, CEN-Saclay, TNO, Studsvik, and JAERI-Tokai; the Requirements Boards of the United Kingdom Department of Industry; impact of President's FY 1983 budget; and the PNL experiment

  11. Journal of Sustainable Development of Energy, Water and Environment Systems - Volume II

    Directory of Open Access Journals (Sweden)

    Neven Duić

    2014-12-01

    Full Text Available The Journal of Sustainable Development of Energy, Water and Environment Systems – JSDEWES is an international journal dedicated to the improvement and dissemination of knowledge on methods, policies and technologies for increasing the sustainability of development by de-coupling growth from natural resources and replacing them with knowledge based economy, taking into account its economic, environmental and social pillars, as well as methods for assessing and measuring sustainability of development, regarding energy, transport, water, environment and food production systems and their many combinations. In total 32 manuscripts were published in Volume II, all of them reviewed by at least two reviewers. The Journal of Sustainable Development of Energy, Water and Environment Systems would like to thank reviewers for their contribution to the quality of the published manuscripts.

  12. Basic Quechua. Volume I: Quechua Reader. Volume II: Quechua Grammar and Dictionary.

    Science.gov (United States)

    Aitken-Soux, Percy G.; Crapo, Richley H.

    Volume I, the reader, has 86 lessons consisting of short passages and vocabulary lists. The language and the stories presented were learned and collected at the Indian community and Hacienda of Cayara near Potosi, Bolivia. Translations of the passages are provided in a separate section. The second volume presents the grammar and phonology of the…

  13. Environmental report 1995. Volume 2

    International Nuclear Information System (INIS)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M.

    1996-09-01

    This is Volume 2 of the Lawrence Livermore National Laboratory's (LLNL's) annual Environmental Report 1995. This volume is intended to support summary data from Volume 1 and is essentially a detailed data report that provides additional data points, where applicable. Some summary data are also included in Volume 2, and more detailed accounts are given of sample collection and analytical methods. Volume 2 includes information in eight chapters on monitoring of air, air effluent, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation, as well as three chapters on ground water protection, compliance self-monitoring and quality assurance

  14. Routine Radiological Environmental Monitoring Plan. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada

    1999-12-31

    The U.S. Department of Energy manages the Nevada Test Site in a manner that meets evolving DOE Missions and responds to the concerns of affected and interested individuals and agencies. This Routine Radiological Monitoring Plan addressess complicance with DOE Orders 5400.1 and 5400.5 and other drivers requiring routine effluent monitoring and environmental surveillance on the Nevada Test Site. This monitoring plan, prepared in 1998, addresses the activities conducted onsite NTS under the Final Environmental Impact Statement and Record of Decision. This radiological monitoring plan, prepared on behalf of the Nevada Test Site Landlord, brings together sitewide environmental surveillance; site-specific effluent monitoring; and operational monitoring conducted by various missions, programs, and projects on the NTS. The plan provides an approach to identifying and conducting routine radiological monitoring at the NTS, based on integrated technical, scientific, and regulatory complicance data needs.

  15. Aerial radiometric and magnetic survey; Brushy Basin detail survey: Price/Salina national topographic map sheets, Utah. Volume III. Area II: graphic data, Section III-IX Final report

    International Nuclear Information System (INIS)

    1981-01-01

    This volume contains all of the graphic data for Area II, which include map lines 1660 to 3400 and 5360 to 5780 and tie lines 6100, 6120, and 6160. Due to the large map scale of the data presented (1:62,500), this area was further subdivided into eleven 7-1/2 min quadrant sheets. It should be noted that TL6100 resides in both Areas II and III. The graphic data for TL6100 are presented in Volume IV - Area III - Graphic Data of this report

  16. Fast beam condition monitor for CMS. Performance and upgrade

    International Nuclear Information System (INIS)

    Leonard, Jessica L.; Bell, Alan; Burtowy, Piotr

    2014-05-01

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

  17. Fast Beam Condition Monitor for CMS: performance and upgrade

    CERN Document Server

    INSPIRE-00009152; Bell, Alan; Burtowy, Piotr; Dabrowski, Anne; Hempel, Maria; Henschel, Hans; Lange, Wolfgang; Lohmann, Wolfgang; Odell, Nathaniel; Penno, Marek; Pollack, Brian; Przyborowski, Dominik; Ryjov, Vladimir; Stickland, David; Walsh, Roberval; Warzycha, Weronika; Zagozdzinska, Agnieszka

    2014-11-21

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

  18. On-line gamma spectroscopy measuring station for cover gas monitoring at KNK II

    International Nuclear Information System (INIS)

    Hoffmann, G.; Letz, K.D.

    1980-02-01

    An automated Ge-γ-spectrometer was developed for cover gas monitoring at KNK II which, by the gamma spectra measured, is to allow the following statements to be made on fuel cladding failure: Type, size, variation with time and subsequent development of the failure. In this report the hardware and software will be explained. Besides, an instruction manual was written for the measuring station, which allows to operate it without detailed knowledge of the manuals for the individual hardware components. (orig.) 891 HP/orig. 892 MKO [de

  19. Project Monitor: Part II. Conservation in small business: an exploratory study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, P Y

    1979-08-01

    Project Monitor examined the energy conservation attitude and behavior of small samples of small business owners/operators in Allegheny County, Pennsylvania, focusing on manufacturing concerns and retailers. Section I reports the findings on the energy conserving behavior of 92 smaller manufacturers and Section II identifies the factors which affect decision making concerning energy consuming activities by the owners/operators of 94 small retail establishments. In each, the impact of Project Pacesetter and of the coal strike and the general energy situation is considered. (MCW)

  20. Environmental control implications of generating electric power from coal. Technology status report. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-12-01

    This is the first in a series of reports evaluating environmental control technologies applicable to the coal-to-electricity process. The technologies are described and evaluated from an engineering and cost perspective based upon the best available information obtained from utility experience and development work in progress. Environmental control regulations and the health effects of pollutants are also reviewed. Emphasis is placed primarily upon technologies that are now in use. For SO/sub 2/ control, these include the use of low sulfur coal, cleaned coal, or flue-gas desulfurization systems. Electrostatic precipitators and fabric filters used for the control of particulate matter are analyzed, and combustion modifications for NO/sub x/ control are described. In each area, advanced technologies still in the development stage are described briefly and evaluated on the basis of current knowledge. Fluidized-bed combustion (FBC) is a near-term technology that is discussed extensively in the report. The potential for control of SO/sub 2/ and NO/sub x/ emissions by use of FBC is analyzed, as are the resulting solid waste disposal problems, cost estimates, and its potential applicability to electric utility systems. Volume II presents the detailed technology analyses complete with reference citations. This same material is given in condensed form in Volume I without references. A brief executive summary is also given in Volume I.

  1. Volume I. Environmental effects on contents of Cs-137 and Sr-90 in milk. Volume II. Appendices

    International Nuclear Information System (INIS)

    1981-01-01

    Milk, animal fodders, soils, humans, livestock, and wildlife on or near 55 dairy farms in Utah were assayed for radionuclide content. Effects of soil chemistry, water supply, plant type, farming practices, geographic location, altitude, rainfall, and other ecological differences were sought by intensive analysis. Although many analyses have not been completed, several cause-effect relationships have been defined. Wet-lands yield more 137 Cs, 131 I, or 90 Sr to milk under like conditions of fallout intensity than dry-lands. In most cases, the station with the highest yield is also practicing wet grazing. 90 Sr and 137 Cs content of milk is enhanced by sandy soils. Increased altitude and higher rainfall lead to higher yields of 90 Sr and 137 Cs in milk. Levels of 137 Cs in milk increase from south to north, and Utah can be divided into several regions, each having a characteristic level of 90 Sr and 137 Cs in milk, meat, and fodders. Poor pastures (over-grazed to the extent that stem bases are eaten and much soil is exposed) yield more 137 Cs and 90 Sr than improved pastures. Feeding green chop alfalfa or putting the animals on the meadows causes marked but temporary increases in the 90 Sr and 137 Cs content of the milk. However, the annual yield for two stations of similar ecology in the same geographic area is essentially the same. Experimental details are presented in Volume I. The appendices in Volume II are made up primarily of the data compiled at the 78 stations

  2. Separation and preconcentration of lead(II), cobalt(II), and nickel(II) on EDTA immobilized activated carbon cloth prior to flame atomic absorption spectrometric determination in environmental samples

    OpenAIRE

    ALOTHMAN, ZEID ABDULLAH; YILMAZ, ERKAN; HABİLA, MOHAMED; SOYLAK, MUSTAFA

    2015-01-01

    The synthesis and characterization of ethylenediaminetetraacetic acid immobilized activated carbon cloth was performed in the present work. It was used for preconcentration-separation of lead(II), cobalt(II), and nickel(II) at trace levels as an adsorbent. Factors including pH, concentration and volume of eluent, sample and eluent flow rates, sample volume, and effect of coexisting ions on the solid phase extraction of analytes were examined. The preconcentration factor was 50. The detection ...

  3. SWIFT/UVOT GRISM MONITORING OF NGC 5548 IN 2013: AN ATTEMPT AT Mg ii REVERBERATION MAPPING

    Energy Technology Data Exchange (ETDEWEB)

    Cackett, E. M.; Troyer, J. [Department of Physics and Astronomy, Wayne State University, 666 W. Hancock St, Detroit, MI 48201 (United States); Gültekin, K. [Department of Astronomy, University of Michigan, 1085 S. University Ave, Ann Arbor, MI 48109 (United States); Bentz, M. C. [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30303 (United States); Fausnaugh, M. M.; Peterson, B. M. [Department of Astronomy, The Ohio State University, 140 West 18th Ave, Columbus, OH 43210 (United States); Vestergaard, M., E-mail: ecackett@wayne.edu [Dark Cosmology Centre, The Niels Bohr Institute, Juliane Maries Vej 30, DK-2100 Copenhagen Ø (Denmark)

    2015-09-10

    Reverberation-mapping-based scaling relations are often used to estimate the masses of black holes from single-epoch spectra of active galactic nuclei (AGNs). While the radius–luminosity relation that is the basis of these scaling relations is determined using reverberation mapping of the Hβ line in nearby AGNs, the scaling relations are often extended to use other broad emission lines, such as Mg ii, in order to get black hole masses at higher redshifts when Hβ is redshifted out of the optical waveband. However, there is no radius–luminosity relation determined directly from Mg ii. Here, we present an attempt to perform reverberation mapping using Mg ii in the well-studied nearby Seyfert 1 NGC 5548. We used Swift to obtain UV grism spectra of NGC 5548 once every two days from 2013 April to September. Concurrent photometric UV monitoring with Swift provides a well determined continuum light curve that shows strong variability. The Mg ii emission line, however, is not strongly correlated with the continuum variability, and there is no significant lag between the two. We discuss these results in the context of using Mg ii scaling relations to estimate high-redshift black hole masses.

  4. Possible interrelationship between changes in F-actin and myosin II, protein phosphorylation, and cell volume regulation in Ehrlich ascites tumor cells

    DEFF Research Database (Denmark)

    Pedersen, S F; Hoffmann, E K

    2002-01-01

    effects on F-actin. The subsequent F-actin depolymerization, however, appeared MLCK- and PKC-dependent, and the initial swelling-induced F-actin depolymerization was MLCK-dependent; both effects were apparently secondary to kinase-mediated effects on cell volume changes. NHE1 in EATC is activated both....... Moreover, Rho kinase inhibition did not significantly affect NHE1 activation, neither by shrinkage nor by CL-A. Implications for the possible interrelationship between changes in F-actin and myosin II, protein phosphorylation, and cell volume regulation are discussed....

  5. The history of the IEA volume II: major policies and actions

    International Nuclear Information System (INIS)

    Scott, R.

    1995-01-01

    Volume II of the History of the International Energy Agency (IEA) continues the story which began with the Origins and Structure of the Agency in Volume I. After examining the industrial countries'energy policies leading up to the 1973-1974 crisis, the current Volume focuses on the new policies adopted in the IEA during its first twenty years.The first part of this book deals with a section on 'Energy Policy Origins of the 1973-1974 Oil Supply Vulnerability : The Optimistic-Passive Approach to Oil Policy'. The main events and developments leading up to the crisis are briefly outlined together with a short presentation of the policy views and critical conclusions that were made on that situation by some of the most knowledgeable oil specialists of the period. The second part surveys IEA oil security, beginning with the oil Emergency Sharing System. The IAE's long-term policies for reducing its Members'dependence on imported oil are the subject of the third part. In this part is described the development of some of the leading IEA work in the field of energy and the environment, the Agency's far-reaching reviews of Members'policies in this sector and a discussion of the 'free markets' policy and of the IEA Shared Goals of 1993. The fourth part deals with the still longer-term Energy Research and Development in the IEA and is a review of the internal organization of IEA work in the R and D field. The fifth part follows with a discussion of the Oil Market policies and practices of the Agency, where the main and durable goals are 'transparency and information dissemination'. The last part addresses the Agency's policies and actions with respect to Co-operation with Non-Member Countries. Then, it takes up Members'policies and activities in connection with the oil producer and consumer country dialogue of 1976-1977 and outlines its disappointing outcome. (O.L.). 2 figs., 13 tabs

  6. Coal liquefaction: A research and development needs assessment: Final report, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, H.D.; Burke, F.P.; Chao, K.C.; Davis, B.H.; Gorbaty, M.L.; Klier, K.; Kruse, C.W.; Larsen, J.W.; Lumpkin, R.E.; McIlwain, M.E.; Wender, I.; Stewart, N.

    1989-03-01

    Volume II of this report on an assessment of research needs for coal liquefaction contains reviews of the five liquefaction technologies---direct, indirect, pyrolysis, coprocessing, and bioconversion. These reviews are not meant to be encyclopedic; several outstanding reviews of liquefaction have appeared in recent years and the reader is referred to these whenever applicable. Instead, these chapters contain reviews of selected topics that serve to support the panel's recommendations or to illustrate recent accomplishments, work in progress, or areas of major research interest. At the beginning of each of these chapters is a brief introduction and a summary of the most important research recommendations brought out during the panel discussions and supported by the material presented in the review. A review of liquefaction developments outside the US is included. 594 refs., 100 figs., 60 tabs.

  7. Research and Development of Hybrid Electric Vehicles CAN-Bus Data Monitor and Diagnostic System through OBD-II and Android-Based Smartphones

    Directory of Open Access Journals (Sweden)

    Yalian Yang

    2013-01-01

    Full Text Available With the rapid development of the smartphone market, future cars seem to have more connections with intelligent cell phone and Internet. Intelligent transportation system (ITS and telematics system have become research focus in recent years. There is an increasing demand for remote monitoring and diagnostic system as the further research of hybrid electric vehicle (HEV goes on. In this paper, a remote controller area network bus (CAN-Bus data monitor and diagnostic system for HEV is presented using on board diagnostic version-II (OBD-II and Android-based smartphone. It is low-cost, convenient, and extensible with smartphone used in the system to realize communication with ELM327 and remote monitoring center wirelessly. The prototype of client and server is developed in Java language, and it is proved by the test that the system works stably and the collected data have practical values.

  8. A Wire Position Monitor System for the ISAC-II Cryomodule Components Alignment

    CERN Document Server

    Rawnsley, B; Dutto, G; Fong, K; Laxdal, R E; Ries, T

    2004-01-01

    TRIUMF is developing ISAC-II, a superconducting (SC) linac. It will comprise 9 cryomodules with a total of 48 niobium cavities and 12 SC solenoids. They must remain aligned at liquid He temperatures: cavities to ±400 μm and solenoids to ±200 μm after a vertical contraction of ~4 mm. A wire position monitor (WPM) system based on a TESLA design has been developed, built, and tested with a prototype cryomodule. The system is based on the measurement of signals induced in pickups by a 215 MHz signal carried by a wire through the WPMs. The wire is stretched between the warm tank walls parallel to the beam axis providing a position reference. The sensors, one per cavity and two per solenoid, are attached to the cold elements to monitor their motion during pre-alignment, pumping and cool down. A WPM consists of four 50 Ω striplines spaced 90° apart. A GaAs multiplexer scans the WPMs and a Bergoz card converts the RF signals to DC X and Y voltages. National Ins...

  9. Economics of place-based monitoring under the safe drinking water act, part II: design and development of place-based monitoring strategies.

    Science.gov (United States)

    Brands, Edwin; Rajagopal, R

    2008-08-01

    The goals of environmental legislation and associated regulations are to protect public health, natural resources, and ecosystems. In this context, monitoring programs should provide timely and relevant information so that the regulatory community can implement legislation in a cost-effective and efficient manner. The Safe Drinking Water Act (SDWA) of 1974 attempts to ensure that public water systems (PWSs) supply safe water to its consumers. As is the case with many other federal environmental statutes, SDWA monitoring has been implemented in relatively uniform fashion across the United States. In this three part series, spatial and temporal patterns in water quality data are utilized to develop, compare, and evaluate the economic performance of alternative place-based monitoring approaches to current monitoring practice. Part II: Several factors affect the performance of monitoring strategies, including: measurable objectives, required precision in estimates, acceptable confidence levels of such estimates, available budget for sampling. In this paper, we develop place-based monitoring strategies based on extensive analysis of available historical water quality data (1960-1994) of 19 Iowa community water systems. These systems supply potable water to over 350,000 people. In the context of drinking water, the objective is to protect public health by utilizing monitoring resources to characterize contaminants that are detectable, and are close to exceeding health standards. A place-based monitoring strategy was developed in which contaminants were selected based on their historical occurrence, rather than their appearance on the SDWA contaminant list. In a subset of the water systems, the temporal frequency of monitoring for one ubiquitous contaminant, nitrate, was tailored to patterns in its historical occurrence and concentration. Three sampling allocation models (linear, quadratic, and cubic) based on historic patterns in peak occurrence were developed and

  10. Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Celal [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Gundogdu, Ali [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Bulut, Volkan Numan [Department of Chemistry, Giresun Faculty of Art and Science, Karadeniz Technical University, 28049 Giresun (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: soylak@erciyes.edu.tr; Elci, Latif [Department of Chemistry, Faculty of Art and Science, Pamukkale University, 20020 Denizli (Turkey); Sentuerk, Hasan Basri [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Tuefekci, Mehmet [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-07-19

    A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L{sup -1} HNO{sub 3} in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 {mu}g L{sup -1}. The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

  11. Microseismic Monitoring of Strainburst Activities in Deep Tunnels at the Jinping II Hydropower Station, China

    Science.gov (United States)

    Xu, N. W.; Li, T. B.; Dai, F.; Zhang, R.; Tang, C. A.; Tang, L. X.

    2016-03-01

    Rockbursts were frequently encountered during the construction of deep tunnels at the Jinping II hydropower station, Southwest China. Investigations of the possibility of rockbursts during tunnel boring machine (TBM) and drilling and blasting (D&B) advancement are necessary to guide the construction of tunnels and to protect personnel and TBM equipment from strainburst-related accidents. A real-time, movable microseismic monitoring system was installed to forecast strainburst locations ahead of the tunnel faces. The spatiotemporal distribution evolution of microseismic events prior to and during strainbursts was recorded and analysed. The concentration of microseismic events prior to the occurrence of strainbursts was found to be a significant precursor to strainbursts in deep rock tunnelling. During a 2-year microseismic investigation of strainbursts in the deep tunnels at the Jinping II hydropower station, a total of 2240 strainburst location forecasts were issued, with 63 % correctly forecasting the locations of strainbursts. The successful forecasting of strainburst locations proved that microseismic monitoring is essential for the assessment and mitigation of strainburst hazards, and can be used to minimise damage to equipment and personnel. The results of the current study may be valuable for the construction management and safety assessment of similar underground rock structures under high in situ stress.

  12. SPORT AND EXERCISE PHYSIOLOGY TESTING Volume one: Sport Testing Volume two: Exercise and Clinical Testing

    Directory of Open Access Journals (Sweden)

    Edward M. Winter

    2007-03-01

    Full Text Available DESCRIPTION The objective of the book is to discuss the theoretical and practical aspects of physiological testing in exercise and sports which is essential to evaluate and monitor developing exercise performance for athletes and public health, and improving quality of life for patients.A board of leading sport and exercise physiologists and scientists are gathered to discuss physiological assessments that have proven validity and reliability, both in sport and health relevant issues. Incidentally, it updates the reader about the current subjects of physiological exertion testing in both research and clinical procedures. Both volumes individually cover the increasing number of available research and review publications, and theoretical explanations are supported by practical examples. A step-by-step and/or checklist method is used in appropriate sections which make the guides more user-friendly than most. PURPOSE The first volume is designed to help readers develop an understanding of the essential concepts of sport specific testing whereas the second volume aims at making the exercise and clinical specific testing comprehensible, dealing with both technical terms and the theories underlying the importance of these tests. AUDIENCE As Guidelines books of the British Association of Sport and Exercise Sciences, it will be of interest to a wide range of students, researchers and practitioners in the sport and exercise disciplines whether they work in the laboratory or in the field. FEATURES The first volume features immediate practical requirements particularly in sport testing. It is composed of five parts with detailed sub-sections in all of them. The topics of the parts are: i general principles, ii methodological issues, iii general procedures, iv sport specific procedures, v special populations.The second volume is also presented in five parts, again with sub-sections in all of them, but considering the requirements in clinical and exercise

  13. Monitoring of plutonium contaminated solid waste streams. Chapter II: principles and theory of radiometric assay

    International Nuclear Information System (INIS)

    Birkhoff, G.; Bondar, L.; Notea, A.; Segal, Y.

    1977-01-01

    The interpretation of a count rate distribution obtained from radiometric assay of a given waste items population in terms of source strength distribution is discussed. A model for the evaluation of errors, arising from non uniform source density distribution (Pu) within the item volume and heterogeneity of matrix materials, is presented. Points concerning calibration procedures and representativity of reference materials are dealt with. Qualification procedures for possible monitoring systems are outlined on the basis of comparison with reference systems. The latter are composed of reference monitors based on high resolution gamma spectrometry and passive and active neutron techniques. The importance of information upon the elemental composition and density distribution of matrix materials for the interpretation of radiometric assay of solid wastes is stressed

  14. Proposed Tenaska Washington II Generation Project : Final Environmental Impact Statement. Volume 2: Public Involvement.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1994-01-01

    In regard to the proposed Tenaska Washington II Generation Project, the goal of the Bonneville Power Administration`s (BPA) Environmental Impact Statement (EIS) public involvement process is to determine the issues to be examined and pertinent analyses to be conducted and to solicit comments on the content and quality of information presented in the Draft Environmental Impact Statement (DEIS). Comments and questions are solicited from the public and government agencies during the scoping process and during the comment period and public hearing on the DEIS, to find out what is of most concern to them. The end product of the public involvement process is the Comment Report which follows in part of this volume on Public Involvement.

  15. Appalachian Rivers II Conference: Technology for Monitoring, Assessing, and Restoring Streams, Rivers, and Watersheds

    Energy Technology Data Exchange (ETDEWEB)

    None available

    1999-07-29

    On July 28-29, 1999, the Federal Energy Technology Center (FETC) and the WMAC Foundation co-sponsored the Appalachian Rivers II Conference in Morgantown, West Virginia. This meeting brought together over 100 manufacturers, researchers, academicians, government agency representatives, watershed stewards, and administrators to examine technologies related to watershed assessment, monitoring, and restoration. Sessions included presentations and panel discussions concerning watershed analysis and modeling, decision-making considerations, and emerging technologies. The final session examined remediation and mitigation technologies to expedite the preservation of watershed ecosystems.

  16. Portable microcomputer for the analysis of plutonium gamma-ray spectra. Volume II. Software description and listings

    International Nuclear Information System (INIS)

    Ruhter, W.D.

    1984-05-01

    A portable microcomputer has been developed and programmed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra. The unit includes a 16-bit LSI-11/2 microprocessor, 32-K words of memory, a 20-character display for user prompting, a numeric keyboard for user responses, and a 20-character thermal printer for hard-copy output of results. The unit weights 11 kg and has dimensions of 33.5 x 30.5 x 23.0 cm. This compactness allows the unit to be stored under an airline seat. Only the positions of the 148-keV 241 Pu and 208-keV 237 U peaks are required for spectral analysis that gives plutonium isotopic ratios and weight percent abundances. Volume I of this report provides a detailed description of the data analysis methodology, operation instructions, hardware, and maintenance and troubleshooting. Volume II describes the software and provides software listings

  17. NURE aerial gamma-ray and magnetic reconnaissance survey, Colorado-Arizona area: Salton Sea NI II-9, Phoenix NI 12-7, El Centro NI II-12, AJO NI 12-10, Lukeville NH 12-1 quadrangles. Volume I. Narrative report

    International Nuclear Information System (INIS)

    1979-11-01

    A rotary-wing reconnaissance high sensitivity radiometric and magnetic survey, encompassing several 1:250,000 quadrangles in southwestern Arizona and southeastern California, was performed. The surveyed area consisted of approximately 9300 line miles. The radiometric data were corrected and normalized to 400 feet terrain clearance. The data were identified as to rock type by correlating the data samples with existing geologic maps. Statistics defining the mean and standard deviation of each rock type are presented as listings in Volume I of this report. The departure of the data from its corresponding mean rock type is computed in terms of standard deviation units and is presented graphically as anomaly maps in Volume II and as computer listings in microfiche form in Volume I. Profiles of the normalized averaged data are contained in Volume II and include traces of the potassium, uranium and thorium count rates, corresponding ratios, and several ancilliary sensor data traces, magnetometer, radio altimeter and barometric pressure height. A description of the local geology is provided, and a discussion of the magnetic and radiometric data is presented together with an evaluation of selected uranium anomalies

  18. Uranium Mill Tailings Remedial Action Project Annual Environmental Monitoring Report calendar year 1992: Volume 1

    International Nuclear Information System (INIS)

    1993-01-01

    This report describes environmental monitoring and compliance at eight UMTRA sites where remedial action was underway during 1992 and at the ten sites that were complete at the end of 1992. Volume I contains information for Ambrosia Lake, NM; Cannonsburg/Burrell, PA; Durango, CO; Falls City, TX; Grand Junction, CO; Green River, UT; and Gunnison, CO. Each site report contains a site description, compliance summary, environmental program information, environmental radiological and non-radiological program information, water resources protection, and quality assurance information

  19. Uranium Mill Tailings Remedial Action Project Annual Environmental Monitoring Report calendar year 1992: Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1993-12-31

    This report describes environmental monitoring and compliance at eight UMTRA sites where remedial action was underway during 1992 and at the ten sites that were complete at the end of 1992. Volume I contains information for Ambrosia Lake, NM; Cannonsburg/Burrell, PA; Durango, CO; Falls City, TX; Grand Junction, CO; Green River, UT; and Gunnison, CO. Each site report contains a site description, compliance summary, environmental program information, environmental radiological and non-radiological program information, water resources protection, and quality assurance information.

  20. New fuzzy EWMA control charts for monitoring phase II fuzzy profiles

    Directory of Open Access Journals (Sweden)

    Ghazale Moghadam

    2016-01-01

    Full Text Available In many quality control applications, the quality of a process or product is explained by the relationship between response variable and one or more explanatory variables, called a profile. In this paper, a new fuzzy EWMA control chart for phase II fuzzy profile monitoring is proposed. To this end, we extend EWMA control charts to its equivalent Fuzzy type and then implement fuzzy ranking methods to determine whether the process fuzzy profile is under or out of control. The proposed method is capable of identifying small changes in process under condition of process profile explaining parameters vagueness, roughness and uncertainty. Determining the source of changes, this method provides us with the possibility of recognizing the causes of process transition from stable mode, removing these causes and restoring the process stable mode.

  1. 2013 Annual Site Inspection and Monitoring Report for Uranium Mill Tailings Radiation Control Act Title II Disposal Sites

    International Nuclear Information System (INIS)

    2013-01-01

    This report, in fulfillment of a license requirement, presents the results of long-term surveillance and maintenance activities conducted by the U.S. Department of Energy (DOE) Office of Legacy Management in 2013 at six uranium mill tailings disposal sites reclaimed under Title II of the Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978. These activities verified that the UMTRCA Title II disposal sites remain in compliance with license requirements. DOE manages six UMTRCA Title II disposal sites under a general license granted by the U.S. Nuclear Regulatory Commission (NRC) established at Title 10 Code of Federal Regulations Part 40.28. Reclamation and site transition activities continue at other sites, and DOE ultimately expects to manage approximately 27 Title II disposal sites. Long-term surveillance and maintenance activities and services for these disposal sites include inspecting and maintaining the sites; monitoring environmental media and institutional controls; conducting any necessary corrective action; and performing administrative, records, stakeholder services, and other regulatory functions. Annual site inspections and monitoring are conducted in accordance with site-specific long-term surveillance plans (LTSPs) and procedures established by DOE to comply with license requirements. Each site inspection is performed to verify the integrity of visible features at the site; to identify changes or new conditions that may affect the long-term performance of the site; and to determine the need, if any, for maintenance, follow-up inspections, or corrective action. LTSPs and site compliance reports are available online at http://www.lm.doe.gov

  2. 2013 Annual Site Inspection and Monitoring Report for Uranium Mill Tailings Radiation Control Act Title II Disposal Sites

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-11-01

    This report, in fulfillment of a license requirement, presents the results of long-term surveillance and maintenance activities conducted by the U.S. Department of Energy (DOE) Office of Legacy Management in 2013 at six uranium mill tailings disposal sites reclaimed under Title II of the Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978. These activities verified that the UMTRCA Title II disposal sites remain in compliance with license requirements. DOE manages six UMTRCA Title II disposal sites under a general license granted by the U.S. Nuclear Regulatory Commission (NRC) established at Title 10 Code of Federal Regulations Part 40.28. Reclamation and site transition activities continue at other sites, and DOE ultimately expects to manage approximately 27 Title II disposal sites. Long-term surveillance and maintenance activities and services for these disposal sites include inspecting and maintaining the sites; monitoring environmental media and institutional controls; conducting any necessary corrective action; and performing administrative, records, stakeholder services, and other regulatory functions. Annual site inspections and monitoring are conducted in accordance with site-specific long-term surveillance plans (LTSPs) and procedures established by DOE to comply with license requirements. Each site inspection is performed to verify the integrity of visible features at the site; to identify changes or new conditions that may affect the long-term performance of the site; and to determine the need, if any, for maintenance, follow-up inspections, or corrective action. LTSPs and site compliance reports are available online at http://www.lm.doe.gov

  3. Verification and validation guidelines for high integrity systems. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D. [SoHaR, Inc., Beverly Hills, CA (United States)

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities.

  4. Verification and validation guidelines for high integrity systems. Volume 1

    International Nuclear Information System (INIS)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D.

    1995-03-01

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities

  5. GENII [Generation II]: The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs

  6. GENII (Generation II): The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs.

  7. Household environmental monitoring project, volume I : main report, volume 2 : appendices

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, J.; Goemans, M.; Goemans, P.C.; Wisniowski, A. [Jane Thompson Architect, Ottawa, ON (Canada); Fugler, D. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada)

    2006-01-15

    Environmentally sustainable behaviour can be motivated by providing homeowners with a clear picture of their environmental impact, tangible reasons for improvement, and tailored solutions. This report presented the results of a study that established a study group of 20 households in an 85-year old community near downtown Ottawa, Ontario to test the above hypothesis. Each household completed surveys about environmental attitudes and household practices. Each household also tracked home heating, electricity and water consumption, and vehicle usage and waste generation over a monitoring period of one week. This report described the study in detail and presented the research plan and methods. It provided a review of related literature, including motivational techniques for encouraging sustainable behaviour; environmental monitoring tools including design tools, global impact assessment tools, federal environmental reduction tools and strategies; analyses of environmentally sustainable projects; and resource conservation techniques and manuals. The report also discussed the selection of the study group; development of monitoring method and forms; household monitoring; household assessment and reporting; community initiatives; and assessment of following year results. It was concluded that the research technique successfully produced reductions in environmental impact among the study group. refs., tabs., figs.

  8. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    Science.gov (United States)

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  9. PATRAM '80. Proceedings. Volume 2

    International Nuclear Information System (INIS)

    Huebner, H.W.

    1980-01-01

    Volume 2 contains papers from the following sessions: Safeguards-Related Problems; Neutronics and Criticality; Operations and Systems Experience II; Plutonium Systems; Intermediate Storage in Casks; Operations and Systems Planning; Institutional Issues; Structural and Thermal Evaluation I; Poster Session B; Extended Testing I; Structural and Thermal Evaluation II; Extended Testing II; and Emergency Preparedness and Response. Individual papers were processed. (LM)

  10. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    Science.gov (United States)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  11. TIBER II/ETR final design report: Volume 3, 5.0 Radiation safety and environment; 6.0 Physics and technology R and D needs

    International Nuclear Information System (INIS)

    Lee, J.D.

    1987-09-01

    This paper discusses the design of the TIBER II Tokamak. This particular volume discusses: safety and environmental requirements and design targets; accident analyses; personnel safety and maintenance exposure; effluent control; waste management and decommissioning; safety considerations in building design; and safety and environmental conclusions and recommendations

  12. Mg II ABSORPTION CHARACTERISTICS OF A VOLUME-LIMITED SAMPLE OF GALAXIES AT z ∼ 0.1

    International Nuclear Information System (INIS)

    Barton, Elizabeth J.; Cooke, Jeff

    2009-01-01

    We present an initial survey of Mg II absorption characteristics in the halos of a carefully constructed, volume-limited subsample of galaxies embedded in the spectroscopic part of the Sloan Digital Sky Survey (SDSS). We observed quasars near sightlines to 20 low-redshift (z ∼ 0.1), luminous (M r + 5log h ≤-20.5) galaxies in SDSS DR4 and DR6 with the LRIS-B spectrograph on the Keck I telescope. The primary systematic criteria for the targeted galaxies are a redshift z ∼> 0.1 and the presence of an appropriate bright background quasar within a projected 75 h -1 kpc of its center, although we preferentially sample galaxies with lower impact parameters and slightly more star formation within this range. Of the observed systems, six exhibit strong (W eq (2796) ≥ 0.3 A) Mg II absorption at the galaxy's redshift, six systems have upper limits which preclude strong Mg II absorption, while the remaining observations rule out very strong (W eq (2796) ≥ 1-2 A) absorption. The absorbers fall at higher impact parameters than many non-absorber sightlines, indicating a covering fraction f c ∼ -1 kpc (f c ∼ 0.25). The data are consistent with a possible dependence of covering fraction and/or absorption halo size on the environment or star-forming properties of the central galaxy.

  13. Development of bunch shape monitor for high-intensity beam on the China ADS proton LINAC Injector II

    Science.gov (United States)

    Zhu, Guangyu; Wu, Junxia; Du, Ze; Zhang, Yong; Xue, Zongheng; Xie, Hongming; Wei, Yuan; Jing, Long; Jia, Huan

    2018-05-01

    The development, performance, and testing of the longitudinal bunch shape monitor, namely, the Fast Faraday Cup (FFC), are presented in this paper. The FFC is an invasive instrument controlled by a stepper motor, and its principle of operation is based on a strip line structure. The longitudinal bunch shape was determined by sampling a small part of the beam hitting the strip line through a 1-mm hole. The rise time of the detector reached 24 ps. To accommodate experiments that utilize high-intensity beams, the materials of the bunch shape monitor were chosen to sustain high temperatures. Water cooling was also integrated in the detector system to enhance heat transfer and prevent thermal damage. We also present an analysis of the heating caused by the beam. The bunch shape monitor has been installed and commissioned at the China ADS proton LINAC Injector II.

  14. Comparative ranking of 0. 1-10 MW/sub e/ solar thermal electric power systems. Volume II. Supporting data. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, J.P.; Brown, K.C.; Finegold, J.G.; Gresham, J.B.; Herlevich, F.A.; Kriz, T.A.

    1980-07-01

    This report is part of a two-volume set summarizing the results of a comparative ranking of generic solar thermal concepts designed specifically for electric power generation. The original objective of the study was to project the mid-1990 cost and performance of selected generic solar thermal electric power systems for utility applications and to rank these systems by criteria that reflect their future commercial acceptance. This study considered plants with rated capacities of 1-10 MW/sub e/, operating over a range of capacity factors from the no-storage case to 0.7 and above. Later, the study was extended to include systems with capacities from 0.1 to 1 MW/sub e/, a range that is attractive to industrial and other nonutility applications. Volume I summarizes the results for the full range of capacities from 0.1 to 1.0 MW/sub e/. Volume II presents data on the performance and cost and ranking methodology.

  15. Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.

    Science.gov (United States)

    Cavalcante, Alexandre N; Martin, Yvette N; Sprung, Juraj; Imsirovic, Jasmin; Weingarten, Toby N

    2017-12-20

    An electrical impedance-based noninvasive respiratory volume monitor (RVM) accurately reports minute volume, tidal volume and respiratory rate. Here we used the RVM to quantify the occurrence of and evaluate the ability of clinical factors to predict respiratory depression in the post-anesthesia care unit (PACU). RVM generated respiratory data were collected from spontaneously breathing patients following intraperitoneal surgeries under general anesthesia admitted to the PACU. Respiratory depression was defined as low minute ventilation episode (LMVe, respiratory rate (respiratory rate was a poor predictor of LMVe (sensitivity = 11.8%). Other clinical variables (e.g., obstructive sleep apnea) were not found to be predictors of LMVe. Using RVM we identified that mild, clinically nondetectable, respiratory depression prior to opioid administration in the PACU was associated with the development of substantial subsequent respiratory depression during the PACU stay.

  16. International Linear Collider Technical Design Report (Volumes 1 through 4)

    Energy Technology Data Exchange (ETDEWEB)

    Harrison M.

    2013-03-27

    The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

  17. Draft Site Treatment Plan (DSTP), Volumes I and II

    International Nuclear Information System (INIS)

    D'Amelio, J.

    1994-01-01

    Site Treatment Plans (STP) are required for facilities at which the DOE generates or stores mixed waste. This Draft Site Treatment Plan (DSTP) the second step in a three-phase process, identifies the currently preferred options for treating mixed waste at the Savannah River Site (SRS) or for developing treatment technologies where technologies do not exist or need modification. The DSTP reflects site-specific preferred options, developed with the state's input and based on existing available information. To the extent possible, the DSTP identifies specific treatment facilities for treating the mixed waste and proposes schedules. Where the selection of specific treatment facilities is not possible, schedules for alternative activities such as waste characterization and technology assessment are provided. All schedule and cost information presented is preliminary and is subject to change. The DSTP is comprised of two volumes: this Compliance Plan Volume and the Background Volume. This Compliance Plan Volume proposes overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) of RCRA and procedures for converting the target dates into milestones to be enforced under the Order. The more detailed discussion of the options contained in the Background Volume is provided for informational purposes only

  18. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    Science.gov (United States)

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios 70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential emptying problems from those with sufficient gastric emptying. Refractometry and measurement of the BV may improve the clinical utilization of GRVs, by its ability to identify the component of formula within gastric contents and track changes in that component related

  19. Development of a wireless MEMS multifunction sensor system and field demonstration of embedded sensors for monitoring concrete pavements, volume II

    Science.gov (United States)

    2016-08-01

    This two-pronged study evaluated the performance of commercial off-the-shelf (COTS) micro-electromechanical sensors and systems (MEMS) embedded in concrete pavement (Final Report Volume I) and developed a wireless MEMS multifunctional sensor system f...

  20. Bibliography of mass spectroscopy literature for 1972 compiled by a computer method. Volume II. Key Word Out of Context (KWOC) Index

    International Nuclear Information System (INIS)

    Capellen, J.; Svec, H.J.; Sage, C.R.; Sun, R.

    1975-08-01

    This report covers the year 1972, and lists approximately 10,000 articles of interest to mass spectroscopists. This two-volume report consists of three sections. Vol. II contains the Key Word Out of Context Index (KWOC Index) section. The KWOC Index lists the key words, the reference numbers of the articles in which the key word appears, and the first 100 characters of the title

  1. The Evaluation of a Noninvasive Respiratory Volume Monitor in Pediatric Patients Undergoing General Anesthesia.

    Science.gov (United States)

    Gomez-Morad, Andrea D; Cravero, Joseph P; Harvey, Brian C; Bernier, Rachel; Halpin, Erin; Walsh, Brian; Nasr, Viviane G

    2017-12-01

    Pediatric patients following surgery are at risk for respiratory compromise such as hypoventilation and hypoxemia depending on their age, comorbidities, and type of surgery. Quantitative measurement of ventilation in nonintubated infants/children is a difficult and inexact undertaking. Current respiratory assessment in nonintubated patients relies on oximetry data, respiratory rate (RR) monitors, and subjective clinical assessment, but there is no objective measure of respiratory parameters that could be utilized to predict early respiratory compromise. New advances in technology and digital signal processing have led to the development of an impedance-based respiratory volume monitor (RVM, ExSpiron, Respiratory Motion, Inc, Waltham, MA). The RVM has been shown to provide accurate real-time, continuous, noninvasive measurements of tidal volume (TV), minute ventilation (MV), and RR in adult patients.In this prospective observational study, our primary aim was to determine whether the RVM accurately measures TV, RR, and MV in pediatric patients. A total of 72 pediatric patients (27 females, 45 males), ASA I to III, undergoing general anesthesia with endotracheal intubation were enrolled. After endotracheal intubation, continuous data of MV, TV, and RR were recorded from the RVM and an in-line monitoring spirometer (NM3 monitor, Phillips Healthcare). RVM and NM3 measurements of MV, TV, and RR were compared during a 10-minute period prior to the incision ("Presurgery") and a 10-minute period after the end of surgery ("Postsurgery"). Relative errors were calculated over 1-minute segment within each 10-minute period. Bias, precision, and accuracy were calculated using Bland-Altman analyses and paired-difference equivalence tests were performed. Combined across the Presurgery and Postsurgery periods, the RVM's mean measurement bias (RVM - NM3 measurement) for MV was -3.8% (95% limits of agreement) (±1.96 SD): (-19.9% to 12.2%), for TV it was -4.9 (-21.0% to 11.3%), and

  2. Safety Specialist Manpower, Manpower Resources. Volumes II and III.

    Science.gov (United States)

    Booz Allen and Hamilton, Inc., Washington, DC.

    These second and third volumes of a four-volume study of manpower in state highway safety programs over the next decade estimate manpower resources by state and in national aggregate and describe present and planned training programs for safety specialists. For each educational level, both total manpower and manpower actually available for…

  3. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  4. Magnetotelluric Detection Thresholds as a Function of Leakage Plume Depth, TDS and Volume

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Buscheck, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mansoor, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-21

    We conducted a synthetic magnetotelluric (MT) data analysis to establish a set of specific thresholds of plume depth, TDS concentration and volume for detection of brine and CO2 leakage from legacy wells into shallow aquifers in support of Strategic Monitoring Subtask 4.1 of the US DOE National Risk Assessment Partnership (NRAP Phase II), which is to develop geophysical forward modeling tools. 900 synthetic MT data sets span 9 plume depths, 10 TDS concentrations and 10 plume volumes. The monitoring protocol consisted of 10 MT stations in a 2×5 grid laid out along the flow direction. We model the MT response in the audio frequency range of 1 Hz to 10 kHz with a 50 Ωm baseline resistivity and the maximum depth up to 2000 m. Scatter plots show the MT detection thresholds for a trio of plume depth, TDS concentration and volume. Plumes with a large volume and high TDS located at a shallow depth produce a strong MT signal. We demonstrate that the MT method with surface based sensors can detect a brine and CO2 plume so long as the plume depth, TDS concentration and volume are above the thresholds. However, it is unlikely to detect a plume at a depth larger than 1000 m with the change of TDS concentration smaller than 10%. Simulated aquifer impact data based on the Kimberlina site provides a more realistic view of the leakage plume distribution than rectangular synthetic plumes in this sensitivity study, and it will be used to estimate MT responses over simulated brine and CO2 plumes and to evaluate the leakage detectability. Integration of the simulated aquifer impact data and the MT method into the NRAP DREAM tool may provide an optimized MT survey configuration for MT data collection. This study presents a viable approach for sensitivity study of geophysical monitoring methods for leakage detection. The results come in handy for rapid assessment of leakage detectability.

  5. Java online monitoring framework

    International Nuclear Information System (INIS)

    Ronan, M.; Kirkby, D.; Johnson, A.S.; Groot, D. de

    1997-10-01

    An online monitoring framework has been written in the Java Language Environment to develop applications for monitoring special purpose detectors during commissioning of the PEP-II Interaction Region. PEP-II machine parameters and signals from several of the commissioning detectors are logged through VxWorks/EPICS and displayed by Java display applications. Remote clients are able to monitor the machine and detector performance using graphical displays and analysis histogram packages. In this paper, the design and implementation of the object-oriented Java framework is described. Illustrations of data acquisition, display and histograming applications are also given

  6. Direct liquid content measurement applicable for He II space cryostats

    International Nuclear Information System (INIS)

    Wanner, M.

    1988-01-01

    A direct calorimetric method for content measurement in the He II cryostat ISO was assessed. A well defined heat pulse into the He II bath causes a small temperature increase which can be measured and directly correlated to the liquid mass through the He II specific heat. To study this method under the potential zero gravity constraints of disconnected liquid volumes a setup was established for investigating heat transfer between separated liquid volumes. The results for different fluid configurations confirm that even for completely disconnected volumes the heat is almost immediately distributed throughout the whole liquid by evaporation and recondensation

  7. An Independent Scientific Assessment of Well Stimulation in California Volume III

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jane C.S. [California Council on Science and Technology, Sacramento, CA (United States); Feinstein, Laura C. [California Council on Science and Technology, Sacramento, CA (United States); Birkholzer, Jens [California Council on Science and Technology, Sacramento, CA (United States); Foxall, William [California Council on Science and Technology, Sacramento, CA (United States); Houseworth, James [California Council on Science and Technology, Sacramento, CA (United States); Jordan, Preston [California Council on Science and Technology, Sacramento, CA (United States); Lindsey, Nathaniel [California Council on Science and Technology, Sacramento, CA (United States); Maddalena, Randy [California Council on Science and Technology, Sacramento, CA (United States); McKone, Thomas [California Council on Science and Technology, Sacramento, CA (United States); Stringfellow, William [California Council on Science and Technology, Sacramento, CA (United States); Ulrich, Craig [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heberger, Matthew [Pacific Inst., Oakland, CA (United States); Shonkoff, Seth [PSE Healthy Energy, Berkeley, CA (United States); Brandt, Adam [Stanford Univ., CA (United States); Ferrar, Kyle [The FracTracker Alliance, Oakland, CA (United States); Gautier, Donald [DonGautier LLC., Palo Alto, CA (United States); Phillips, Scott [California State Univ. Stanislaus, Turlock, CA (United States); Greenfield, Ben [Univ. of California, Berkeley, CA (United States); Jerrett, Michael L.B. [Univ. of California, Los Angeles, CA (United States)

    2015-07-01

    This study is issued in three volumes. Volume I, issued in January 2015, describes how well stimulation technologies work, how and where operators deploy these technologies for oil and gas production in California, and where they might enable production in the future. Volume II, issued in July 2015, discusses how well stimulation could affect water, atmosphere, seismic activity, wildlife and vegetation, and human health. Volume II reviews available data, and identifies knowledge gaps and alternative practices that could avoid or mitigate these possible impacts. Volume III, this volume, presents case studies that assess environmental issues and qualitative risks for specific geographic regions. The Summary Report summarizes key findings, conclusions and recommendations of all three volumes.

  8. Assessment of the health and environmental effects of power generation in the Midwest. Volume II. Ecological effects

    Energy Technology Data Exchange (ETDEWEB)

    Dvorak, A J; Pentecost, E D

    1977-04-01

    This report presents an initial evaluation of the major health and environmental issues associated with increased coal use in the six Midwestern states of Illinois, Indiana, Michigan, Minnesota, Ohio, and Wisconsin. Using an integrated assessment approach, the evaluation proceeds from a base-line scenario of energy demand and facility siting for the period 1975 to 2020. Emphasis is placed on impacts from coal extraction, land reclamation, coal combustion for electrical generation, and coal gasification. The range of potential impacts and constraints is illustrated by a second scenario that represents an expected upper limit for coal utilization in Illinois. Volume I of the report includes a characterization of the energy demand and siting scenarios, coal related technologies, and coal resources, and the related impacts on air quality, water quality, and human health. Volume II includes background information on the native ecosystems, climate, soils, and agricultural land use and a description of the ecological impacts expected from coal utilization in southern Illinois, which as ecosystems representative of a large segment of the six-state area.

  9. The new area monitoring system and the fuel database of the TRIGA Mark II reactor in Vienna

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Hofbauer, M.; Schwarz, V.

    2004-01-01

    The 250 kW TRIGA Mark-II reactor operates since March 1962 at the Atominstitut, Vienna, Austria. Its main tasks are nuclear education and training in the fields of neutron- and solid state physics, nuclear technology, reactor safety, radiochemistry, radiation protection and dosimetry, and low temperature physics and fusion research. Academic research is carried out by students in the above mentioned fields coordinated and supervised by about 70 staff members with the aim of a masters- or PhD degree in one of the above mentioned areas. After 25 years of successful operation, it was necessary to exchange the old area monitoring system with a new digital one. The purpose of the new system is the permanent control of the reactor hall, the primary and secondary cooling system and the monitoring of the ventilation system. The paper describes the development and implementation of the new area monitoring system. The second topic in this paper describes the development of the new fuel database. Since March 7th, 1962, the TRIGA Mark II reactor Vienna operates with an average of 263 MWh per year, which corresponds to a uranium burn-up of 13.7 g per year. Presently we have 81 TRIGA fuel elements in the core, 55 of them are old aluminium clad elements from the initial criticality while the rest are stainless steel clad elements which had been added later to compensate the uranium consumption. Because 67 % of the elements are older than 40 years, it was necessary to put the history of every element in a database, to get an easy access to all the relevant data for every element in our facility. (author)

  10. Stream II-V5: Revision Of Stream II-V4 To Account For The Effects Of Rainfall Events

    International Nuclear Information System (INIS)

    Chen, K.

    2010-01-01

    STREAM II-V4 is the aqueous transport module currently used by the Savannah River Site emergency response Weather Information Display (WIND) system. The transport model of the Water Quality Analysis Simulation Program (WASP) was used by STREAM II to perform contaminant transport calculations. WASP5 is a US Environmental Protection Agency (EPA) water quality analysis program that simulates contaminant transport and fate through surface water. STREAM II-V4 predicts peak concentration and peak concentration arrival time at downstream locations for releases from the SRS facilities to the Savannah River. The input flows for STREAM II-V4 are derived from the historical flow records measured by the United States Geological Survey (USGS). The stream flow for STREAM II-V4 is fixed and the flow only varies with the month in which the releases are taking place. Therefore, the effects of flow surge due to a severe storm are not accounted for by STREAM II-V4. STREAM II-V4 has been revised to account for the effects of a storm event. The steps used in this method are: (1) generate rainfall hyetographs as a function of total rainfall in inches (or millimeters) and rainfall duration in hours; (2) generate watershed runoff flow based on the rainfall hyetographs from step 1; (3) calculate the variation of stream segment volume (cross section) as a function of flow from step 2; (4) implement the results from steps 2 and 3 into the STREAM II model. The revised model (STREAM II-V5) will find the proper stream inlet flow based on the total rainfall and rainfall duration as input by the user. STREAM II-V5 adjusts the stream segment volumes (cross sections) based on the stream inlet flow. The rainfall based stream flow and the adjusted stream segment volumes are then used for contaminant transport calculations.

  11. Environmental Report 1996, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Harrach, R.J.

    1996-01-01

    This is Volume 2 of the Lawrence Livermore National Laboratory`s (LLNL`s) annual Environmental Report 1996, prepared for the US Department of Energy. Volume 2 supports Volume 1 summary data and is essentially a detailed data report that provides individual data points, where applicable. Volume 2 includes information on monitoring of air, air effluents, sewerable water, surface water, ground water, soil and sediment, vegetation and foodstuff, environmental radiation, and quality assurance.

  12. Spinal level of myelomeningocele lesion as a contributing factor in posterior fossa volume, intracranial cerebellar volume, and cerebellar ectopia.

    LENUS (Irish Health Repository)

    Sweeney, Kieron J

    2013-02-01

    McLone and Knepper\\'s unified theory of Chiari malformation Type II (CM-II) describes how the loss of CSF via the open posterior neuropore fails to create adequate distending pressure for the developing rhomboencephalic vesicle. The authors of the present article describe the relationship between the posterior fossa volume and intracranial cerebellar volume as being related to the distance from the obex of the fourth ventricle to the myelomeningocele lesion using a common mathematical model, the Hagen-Poiseuille law.

  13. Demonstration, testing, & evaluation of in situ heating of soil. Draft final report, Volume II: Appendices A to E

    Energy Technology Data Exchange (ETDEWEB)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-02-12

    This document is a draft final report for US DOE contract entitled, {open_quotes}Demonstration Testing and Evaluation of In Situ Soil Heating,{close_quotes} Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report This document is Volume II, containing appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120{degrees}to 130{degrees}C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow.

  14. Bibliography of Utah radioactive occurrences. Volume II

    International Nuclear Information System (INIS)

    Doelling, H.H.

    1983-07-01

    The references in this bibliography were assembled by reviewing published bibliographies of Utah geology, unpublished reports of the US Geological Survey and the Department of Energy, and various university theses. Each of the listings is cross-referenced by location and subject matter. This report is published in two volumes

  15. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    International Nuclear Information System (INIS)

    Cunnane, J.C.

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste

  16. High-level waste borosilicate glass: A compendium of corrosion characteristics. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Cunnane, J.C. [comp.; Bates, J.K.; Bradley, C.R. [Argonne National Lab., IL (United States)] [and others

    1994-03-01

    The objective of this document is to summarize scientific information pertinent to evaluating the extent to which high-level waste borosilicate glass corrosion and the associated radionuclide release processes are understood for the range of environmental conditions to which waste glass may be exposed in service. Alteration processes occurring within the bulk of the glass (e.g., devitrification and radiation-induced changes) are discussed insofar as they affect glass corrosion.This document is organized into three volumes. Volumes I and II represent a tiered set of information intended for somewhat different audiences. Volume I is intended to provide an overview of waste glass corrosion, and Volume 11 is intended to provide additional experimental details on experimental factors that influence waste glass corrosion. Volume III contains a bibliography of glass corrosion studies, including studies that are not cited in Volumes I and II. Volume I is intended for managers, decision makers, and modelers, the combined set of Volumes I, II, and III is intended for scientists and engineers working in the field of high-level waste.

  17. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    Science.gov (United States)

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic

  18. Hanford spent nuclear fuel project recommended path forward, volume III: Alternatives and path forward evaluation supporting documentation

    International Nuclear Information System (INIS)

    Fulton, J.C.

    1994-10-01

    Volume I of the Hanford Spent Nuclear Fuel Project - Recommended Path Forward constitutes an aggressive series of projects to construct and operate systems and facilities to safely retrieve, package, transport, process, and store K Basins fuel and sludge. Volume II provided a comparative evaluation of four Alternatives for the Path Forward and an evaluation for the Recommended Path Forward. Although Volume II contained extensive appendices, six supporting documents have been compiled in Volume III to provide additional background for Volume II

  19. Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects

    Directory of Open Access Journals (Sweden)

    V.F. Parreira

    2005-07-01

    Full Text Available The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne and flow-oriented (Triflo II and Respirex devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º. Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02 and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01 were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm. Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively. Abdominal motion was larger (P < 0.05 during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex. We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

  20. 12 CFR 1291.7 - Monitoring.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Monitoring. 1291.7 Section 1291.7 Banks and... HOUSING PROGRAM § 1291.7 Monitoring. (a) Competitive application program—(1) Initial monitoring policies... connection with the project. (ii) Back-up and other project documentation. The Bank's written monitoring...

  1. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  2. Draft Strategic Laboratory Missions Plan. Volume II

    International Nuclear Information System (INIS)

    1996-03-01

    This volume described in detail the Department's research and technology development activities and their funding at the Department's laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B ampersand R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department's appropriation to a specific activity description and to specific R ampersand D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R ampersand D performers chosen to execute the Department's missions

  3. Draft Strategic Laboratory Missions Plan. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This volume described in detail the Department`s research and technology development activities and their funding at the Department`s laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B & R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department`s appropriation to a specific activity description and to specific R & D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R & D performers chosen to execute the Department`s missions.

  4. Is orbital volume associated with eyeball and visual cortex volume in humans?

    Science.gov (United States)

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.

  5. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn; Hempel, Maria; Henschel, Hans; Karacheban, Olena; Lange, Wolfgang; Lohmann, Wolfgang; Novgorodova, Olga; Penno, Marek; Walsh, Roberval; Dabrowski, Anne; Guthoff, Moritz; Loos, R; Ryjov, Vladimir; Burtowy, Piotr; Lokhovitskiy, Arkady; Odell, Nathaniel; Przyborowski, Dominik; Stickland, David P; Zagozdzinska, Agnieszka

    2014-01-01

    The CMS beam condition monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be discussed, including results from the January 201...

  6. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn

    2014-01-01

    The CMS beam and radiation monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be shown, including results from the January 201...

  7. Monitoring Water Quality in the Future, Volume 3: Biomonitoring

    NARCIS (Netherlands)

    Zwart D de; ECO

    1995-01-01

    In general terms the problems with the existing water quality monitoring approach concern effective and efficient monitoring strategies. In 1993 the project "Monitoring water quality in the future" started in order to address these problems which will only increase in the future. In the framework of

  8. Resource Conservation and Recovery Act ground-water monitoring projects for Hanford Facilities: Progress report for the period July 1 to September 30, 1989 - Volume 1 - Text

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.M.; Bates, D.J.; Lundgren, R.E.

    1989-12-01

    This is Volume 1 of a two-volume document that describes the progress of 14 Hanford Site ground-water monitoring projects for the period July 1 to September 30, 1989. This volume discusses the projects; Volume 2 provides as-built diagrams, completion/inspection reports, drilling logs, and geophysical logs for wells drilled, completed, or logged during this period. Volume 2 can be found on microfiche in the back pocket of Volume 1. The work described in this document is conducted by the Pacific Northwest Laboratory under the management of Westinghouse Hanford Company for the US Department of Energy. Concentrations of ground-water constituents are compared to federal drinking water standards throughout this document for reference purposes. All drinking water supplied from the sampled aquifer meets regulatory standards for drinking water quality.

  9. Wearable Health Monitoring Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  10. Methods of Celestial Mechanics Volume II: Application to Planetary System, Geodynamics and Satellite Geodesy

    CERN Document Server

    Beutler, Gerhard

    2005-01-01

    G. Beutler's Methods of Celestial Mechanics is a coherent textbook for students as well as an excellent reference for practitioners. Volume II is devoted to the applications and to the presentation of the program system CelestialMechanics. Three major areas of applications are covered: (1) Orbital and rotational motion of extended celestial bodies. The properties of the Earth-Moon system are developed from the simplest case (rigid bodies) to more general cases, including the rotation of an elastic Earth, the rotation of an Earth partly covered by oceans and surrounded by an atmosphere, and the rotation of an Earth composed of a liquid core and a rigid shell (Poincaré model). (2) Artificial Earth Satellites. The oblateness perturbation acting on a satellite and the exploitation of its properties in practice is discussed using simulation methods (CelestialMechanics) and (simplified) first order perturbation methods. The perturbations due to the higher-order terms of the Earth's gravitational potential and reso...

  11. Tracer verification and monitoring of containment systems (II)

    International Nuclear Information System (INIS)

    Williams, C.V.; Dunn, S.D.; Lowry, W.E.

    1997-01-01

    A tracer verification and monitoring system, SEAtrace trademark, has been designed and field tested which uses gas tracers to evaluate, verify, and monitor the integrity of subsurface barriers. This is accomplished using an automatic, rugged, autonomous monitoring system combined with an inverse optimization code. A gaseous tracer is injected inside the barrier and an array of wells outside the barrier are monitored. When the tracer gas is detected, a global optimization code is used to calculate the leak parameters, including leak size, location, and when the leak began. The multipoint monitoring system operates in real-time, can be used to measure both the tracer gas and soil vapor contaminants, and is capable of unattended operation for long periods of time (months). The global optimization code searches multi-dimensional open-quotes spaceclose quotes to find the best fit for all of the input parameters. These parameters include tracer gas concentration histories from multiple monitoring points, medium properties, barrier location, and the source concentration. SEAtrace trademark does not attempt to model all of the nuances associated with multi-phase, multi-component flow, but rather, the inverse code uses a simplistic forward model which can provide results which are reasonably accurate. The system has calculated leak locations to within 0.5 meters and leak radii to within 0.12 meters

  12. Spacecraft Cabin Particulate Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We have built and tested an optical extinction monitor for the detection of spacecraft cabin particulates. This sensor sensitive to particle sizes ranging from a few...

  13. Near infrared spectroscopy combined with multivariate analysis for monitoring the ethanol precipitation process of fraction I + II + III supernatant in human albumin separation

    Science.gov (United States)

    Li, Can; Wang, Fei; Zang, Lixuan; Zang, Hengchang; Alcalà, Manel; Nie, Lei; Wang, Mingyu; Li, Lian

    2017-03-01

    Nowadays, as a powerful process analytical tool, near infrared spectroscopy (NIRS) has been widely applied in process monitoring. In present work, NIRS combined with multivariate analysis was used to monitor the ethanol precipitation process of fraction I + II + III (FI + II + III) supernatant in human albumin (HA) separation to achieve qualitative and quantitative monitoring at the same time and assure the product's quality. First, a qualitative model was established by using principal component analysis (PCA) with 6 of 8 normal batches samples, and evaluated by the remaining 2 normal batches and 3 abnormal batches. The results showed that the first principal component (PC1) score chart could be successfully used for fault detection and diagnosis. Then, two quantitative models were built with 6 of 8 normal batches to determine the content of the total protein (TP) and HA separately by using partial least squares regression (PLS-R) strategy, and the models were validated by 2 remaining normal batches. The determination coefficient of validation (Rp2), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP) and ratio of performance deviation (RPD) were 0.975, 0.501 g/L, 0.465 g/L and 5.57 for TP, and 0.969, 0.530 g/L, 0.341 g/L and 5.47 for HA, respectively. The results showed that the established models could give a rapid and accurate measurement of the content of TP and HA. The results of this study indicated that NIRS is an effective tool and could be successfully used for qualitative and quantitative monitoring the ethanol precipitation process of FI + II + III supernatant simultaneously. This research has significant reference value for assuring the quality and improving the recovery ratio of HA in industrialization scale by using NIRS.

  14. Near infrared spectroscopy combined with multivariate analysis for monitoring the ethanol precipitation process of fraction I+II+III supernatant in human albumin separation.

    Science.gov (United States)

    Li, Can; Wang, Fei; Zang, Lixuan; Zang, Hengchang; Alcalà, Manel; Nie, Lei; Wang, Mingyu; Li, Lian

    2017-03-15

    Nowadays, as a powerful process analytical tool, near infrared spectroscopy (NIRS) has been widely applied in process monitoring. In present work, NIRS combined with multivariate analysis was used to monitor the ethanol precipitation process of fraction I+II+III (FI+II+III) supernatant in human albumin (HA) separation to achieve qualitative and quantitative monitoring at the same time and assure the product's quality. First, a qualitative model was established by using principal component analysis (PCA) with 6 of 8 normal batches samples, and evaluated by the remaining 2 normal batches and 3 abnormal batches. The results showed that the first principal component (PC1) score chart could be successfully used for fault detection and diagnosis. Then, two quantitative models were built with 6 of 8 normal batches to determine the content of the total protein (TP) and HA separately by using partial least squares regression (PLS-R) strategy, and the models were validated by 2 remaining normal batches. The determination coefficient of validation (R p 2 ), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP) and ratio of performance deviation (RPD) were 0.975, 0.501g/L, 0.465g/L and 5.57 for TP, and 0.969, 0.530g/L, 0.341g/L and 5.47 for HA, respectively. The results showed that the established models could give a rapid and accurate measurement of the content of TP and HA. The results of this study indicated that NIRS is an effective tool and could be successfully used for qualitative and quantitative monitoring the ethanol precipitation process of FI+II+III supernatant simultaneously. This research has significant reference value for assuring the quality and improving the recovery ratio of HA in industrialization scale by using NIRS. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Environmental monitoring survey of oil and gas fields in Region II in 2009. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    2010-03-15

    The oil companies Statoil ASA, ExxonMobil Exploration and Production Norway AS, Total E&P Norge AS, Talisman Energy Norge AS and Marathon Petroleum Norge AS commissioned Section of Applied Environmental Research at UNI RESEARCH AS to undertake the monitoring survey of Region II in 2009. Similar monitoring surveys in Region II have been carried out in 1996, 2000, 2003 and 2006. The survey in 2009 included in total 18 fields: Rev, Varg, Sigyn, Sleipner Vest, Sleipner OEst, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Vale, Skirne, Byggve, Heimdal, Volve, Vilje og Alvheim. Sampling was conducted from the vessel MV Libas between May 18 and May 27. Samples were collected from in totally 137 sampling sites, of which 15 were regional sampling sites. Samples for chemical analysis were collected at all sites, whereas samples for benthos analysis were collected at 12 fields. As in previous surveys, Region II is divided into natural sub-regions. One sub-region is shallow (77-96 m) sub-region, a central sub-region (107-130 m) and a northern subregion (115-119 m). The sediments of the shallow sub-region had relatively lower content of TOM and pelite and higher content of fine sand than the central and northern sub-regions. Calculated areas of contamination are shown for the sub-regions in Table 1.1. The fields Sigyn, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Skirne, Byggve, Vilje og Alvheim showed no contamination of THC. At the other fields there were minor changes from 2006. The concentrations of barium increased in the central sub-region from 2006 to 2009, also at fields where no drilling had been undertaken during the last years. The same laboratory and methods are used during the three last regional investigations. The changes in barium concentrations may be due to high variability of barium concentrations in the sediments. This is supported by relatively large variations in average barium concentrations at the regional sampling sites in

  16. Atlas of total body radionuclide imaging. Volume I and II

    International Nuclear Information System (INIS)

    Fordham, E.W.; Ali, A.; Turner, D.A.; Charters, J.

    1982-01-01

    This two-volume work on total body imaging may well be regarded by future historians of nuclear medicine as representing the high points in the art of total body imaging in clinical nuclear medicine. With regard to information content and volume, it is the largest collection of well-interpreted, beautifully reproduced, total body images available to date. The primary goal of this atlas is to demonstrate patterns of abnormality in both typical and less typical variations. This goal is accomplished with many well-described examples of technical artifacts, of normal variants, of common and of rare diseases, and of pitfalls in interpretations. Volume I is entirely dedicated to skeletal imaging with Tc-99m labeled phosphates or phosphonates. The volume is divided into 22 chapters, which include chapters on methodology and instrumentation, chapters on the important bone diseases and other topics such as a treatise on false-negative and false-positive scans, and soft tissue and urinary tract abnormalities recognizable on bone scintigrams

  17. Free radicals in biology. Volume II

    International Nuclear Information System (INIS)

    Pryor, W.A.

    1976-01-01

    This volume continues the treatment of topics in free radical biology and free radical pathology from Volume I. In the first chapter, pyridinyl radicals, radicals which are models for those derived from NAD, are discussed. Pyridinyl radicals can be synthesized and isolated and directly studied in a number of chemical systems. The next chapter treats the role of glutathione in the cell. It is becoming even more apparent that this vital thiol controls a large number of important cellular functions. The GSH/GSSG balance has recently been implicated as a control for cellular development; this balance also may be important in relaying the effects of oxidants from one site to another in the body. The next chapter outlines the reactions of singlet oxygen; some of these involve free radicals and some do not. This reactive intermediate appears to be important both in photochemical smog and in cellular chemistry where singlet oxygen is produced by nonphotochemical processes. The production of free radicals from dry tissues, a controversial area with conflicting claims is reviewed. The next chapter outlines the current status of the studies of photochemical smog. The next two chapters treat specific reactive materials which are present in smog. The first discusses the chemistry of nitrogen oxides and ozone. The second chapter treats the chemistry of the peroxyacyl nitrites. These compounds, although present in only small concentration, are among the most toxic components of smog. The last two chapters treat radiation damage to proteins and radiation protection and radical reactions produced by radiation in nucleic acids

  18. Apparent molar volumes and compressibilities of alkaline earth metal ions in methanol and dimethylsulfoxide

    International Nuclear Information System (INIS)

    Warminska, Dorota; Wawer, Jaroslaw; Grzybkowski, Waclaw

    2010-01-01

    Temperature dependencies of density of magnesium (II), calcium (II), strontium (II), barium (II) perchlorates as well as beryllium (II), and sodium trifluoromethanesulfonates in methanol and dimethylsulfoxide have been determined over the composition range studied. From density data the apparent molar volumes and partial molar volumes of the salts at infinite dilution as well as the expansibilities have been evaluated. The apparent molar isentropic compressibilities of alkaline earth metal perchlorates and beryllium (II) and sodium triflates in methanol and DMSO have been calculated from sound speed data obtained at T = 298.15 K.

  19. Persistent type II endoleak after EVAR: the predictive value of the AAA thrombus volume.

    Science.gov (United States)

    Gallitto, Enrico; Gargiulo, Mauro; Mascoli, Chiara; Freyrie, Antonio; DE Matteis, Massimo; Serra, Carla; Bianchini Massoni, Claudio; Faggioli, Gianluca; Stella, Andrea

    2018-02-01

    Persistent type II endoleaks (ELIIp, ≥6 months) after an endovascular aneurysm repair (EVAR) can be associated with adverse outcomes. The aims of this study are the evaluation of the incidence of ELIIp, their preoperative morphological predictive features (PMF) and the post-EVAR abdominal aortic aneurysm (AAA) evolution in the presence of ELIIp. Patients underwent EVAR between 2008 and 2010 were prospectively collected. Cases with ELIIp (group A: AG) were identified. A control group without ELIIp (group B: BG), homogeneous for clinical characteristics, follow-up timing and methods (CTA and/or CEUS at 6.12 months and yearly thereafter) was retrospectively selected. The PMF evaluated by computed-tomography-angiography (CTA) were: AAA-diameter, number and diameter of AAA efferent patent vessels (EPV), AAA-total volume (TV), AAA-thrombus volume (THV) and TV/THV rate (%VR). Volumes were calculated by the dedicated vessels analysis software. AG and BG were compared. The primary endpoint was to evaluate the incidence of ELIIp. Secondary endpoints were to analyze the relation between PMF and ELIIp and to assess the post-EVAR AAA-evolution in the presence of ELIIp. Between 2008 and 2010, 200 patients underwent EVAR to treat AAA electively. An ELIIp was detected in 35cases (17.5%) (AG). Twenty-seven patients (13.5%) were included in BG. An overall of 62 patients (GA+GB) were analyzed. The mean pre-operative AAA diameter and EPV were 58±11.6 mm and 5.5±1.8 mm, respectively. The mean TV and THV were 187±111.5 cc and 82±75 cc, respectively. The median %VR was 42.3%. ELIIp was correlated to EPV≥6 (χ2, p=.015) and %VR AAA growth post-EVAR. ELIIp is a not rare complication and it could require re-interventions. Our data suggest that VEP≥6 or %VT<40% are risk factors for ELIIp. No PMF was able to predict the ELIIp evolution. The relative high rate of re-interventions, could suggest the need of adjunctive/preventing primary procedures in patients at high-risk for ELIIp.

  20. Blanket comparison and selection study. Volume II

    International Nuclear Information System (INIS)

    1983-10-01

    This volume contains extensive data for the following chapters: (1) solid breeder tritium recovery, (2) solid breeder blanket designs, (3) alternate blanket concept screening, and (4) safety analysis. The following appendices are also included: (1) blanket design guidelines, (2) power conversion systems, (3) helium-cooled, vanadium alloy structure blanket design, (4) high wall loading study, and (5) molten salt safety studies

  1. Demonstration, testing, ampersand evaluation of in situ heating of soil. Draft final report, Volume II: Appendices A to E

    International Nuclear Information System (INIS)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-01-01

    This document is a draft final report for US DOE contract entitled, open-quotes Demonstration Testing and Evaluation of In Situ Soil Heating,close quotes Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report This document is Volume II, containing appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120 degrees to 130 degrees C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow

  2. Monitors for TJII

    International Nuclear Information System (INIS)

    Tafalla, D.; Tabares, F.L.; Ortiz, P.; Lopez-Sanchez, A.; Martin Fresno, L.M.; Sanchez Sarabia, E.; Encabo, J.

    1998-06-01

    A set of monitors for the measurement of Hα radiation (656.3 nm) have been installed in TJ-II stellarator. The detectors are placed directly on the windows of the chamber and they are built using Si photodiodes and interference filters with a compact design that make easy their handling and maintenance. Here we describe the mechanical and electrical design of the monitors, their position in TJ-II and some examples of their working during the first discharges of the machine. (Author) 3 refs

  3. Automated contamination monitoring for hot particles

    International Nuclear Information System (INIS)

    Johnstone, G.; Case, L.

    1987-01-01

    INS Corp., the largest nuclear laundry company in the United States, has recently developed two types of automated contamination monitoring systems: 1) the Automated Laundry Monitor (ALM), which provides quality assurance monitoring for protective clothing contamination and 2) a low-level automated monitoring system for Plastic Volume Reduction Service (PVRS). The presentation details the inaccuracies associated with hand-probe frisking which led to the development of the ALM. The ALM was designed for 100% quality assurance monitoring of garments to the most stringent customer requirements. A review of why the ALM is essential in verifying the absence of hot particles on garments is given. The final topic addresses the expansion of the ALM technology in support of the INS Plastic Volume Reduction Service by monitoring decontaminated plastics to free release levels. This presentation reviews the design and operation of both monitoring systems

  4. Fixed site neutralization model programmer's manual. Volume II

    International Nuclear Information System (INIS)

    Engi, D.; Chapman, L.D.; Judnick, W.; Blum, R.; Broegler, L.; Lenz, J.; Weinthraub, A.; Ballard, D.

    1979-12-01

    This report relates to protection of nuclear materials at nuclear facilities. This volume presents the source listings for the Fixed Site Neutralization Model and its supporting modules, the Plex Preprocessor and the Data Preprocessor

  5. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  6. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  7. Routine Radiological Environmental Monitoring Plan, Volume 2 Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada

    1998-12-31

    Supporting material for the plan includes: QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS AIR; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR WATER ON AND OFF THE NEVADA TEST SITE; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS BIOTA; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR DIRECT RADIATION MONITORING; DATA QUALITY OBJECTIVES PROCESS; VADOSE ZONE MONITORING PLAN CHECKLIST.

  8. TECHNICAL REPORT ON TECHNOLOGICALLY ENHANCED NATURALLY OCCURRING RADIOACTIVE MATERIALS FROM URANIUM MINING, VOLUME II: INVESTIGATION OF POTENTIAL HEALTH, GEOGRAPHIC, AND ENVIRONMENTAL ISSUES OF ABANDONED URANIUM MINES

    Science.gov (United States)

    Volume II investigates the potential radiogenic risks from abandoned uranium mines and evaluates which may pose the greatest hazards to members of the public and to the environment. The intent of this report is to identify who may be most likely to be exposed to wastes at small a...

  9. Interim report on the development and application of environmental mapped data digitization, encoding, analysis, and display software for the ALICE system. Volume II. [MAP, CHAIN, FIX, and DOUT, in FORTRAN IV for PDP-10

    Energy Technology Data Exchange (ETDEWEB)

    Amiot, L.W.; Lima, R.J.; Scholbrock, S.D.; Shelman, C.B.; Wehman, R.H.

    1979-06-01

    Volume I of An Interim Report on the Development and Application of Environmental Mapped Data Digitization, Encoding, Analysis, and Display Software for the ALICE System provided an overall description of the software developed for the ALICE System and presented an example of its application. The scope of the information presented in Volume I was directed both to the users and developers of digitization, encoding, analysis, and display software. Volume II presents information which is directly related to the actual computer code and operational characteristics (keys and subroutines) of the software. Volume II will be of more interest to developers of software than to users of the software. However, developers of software should be aware that the code developed for the ALICE System operates in an environment where much of the peripheral hardware to the PDP-10 is ANL/AMD built. For this reason, portions of the code may have to be modified for implementation on other computer system configurations. 11 tables.

  10. Principles of quantum computation and information volume II

    International Nuclear Information System (INIS)

    Kok, P

    2007-01-01

    Any new textbook in quantum information has some pretty strong competition to contend with. Not only is there the classic text by Nielsen and Chuang from 2000, but also John Preskill's lecture notes, available for free online. Nevertheless, a proper textbook seems more enduring than online notes, and the field has progressed considerably in the seven years since Nielsen and Chuang was published. A new textbook is a great opportunity to give a snapshot of our current state of knowledge in quantum information. Therein also lies a problem: The field has expanded so much that it is impossible to cover everything at the undergraduate level. Quantum information theory is relevant to an extremely large portion of physics, from solid state and condensed matter physics to particle physics. Every discipline that has some relation to quantum mechanics is affected by our understanding of quantum information theory. Those who wish to write a book on quantum information therefore have to make some profound choices: Do you keep the ultimate aim of a quantum computer in mind, or do you focus on quantum communication and precision measurements as well? Do you describe how to build a quantum computer with all possible physical systems or do you present only the underlying principles? Do you include only the tried and tested ideas, or will you also explore more speculative directions? You don't have to take a black-or-white stance on these questions, but how you approach them will profoundly determine the character of your book. The authors of 'Principles of Quantum Computation and Information (Volume II: Basic Tools and Special Topics)' have chosen to focus on the construction of quantum computers, but restrict themselves mainly to general techniques. Only in the last chapter do they explicitly address the issues that arise in the different implementations. The book is the second volume in a series, and consists of four chapters (labelled 5 to 8) called 'Quantum Information Theory

  11. Monitoring Heavy Metal Contents with Sphagnum Junghuhnianum Moss Bags in Relation to Traffic Volume in Wuxi, China

    Directory of Open Access Journals (Sweden)

    Rong Hu

    2018-02-01

    Full Text Available Despite its small size, a moss bag can reveal the different temporal and spatial deposition patterns of pollutants at a particular site; therefore, researchers can use moss bags to determine pollution sources and to put forward strategies for pollution control. Although the use of moss bags to monitor atmospheric pollution has been widely reported in Europe, there are few such empirical studies in China. Thus, in this study, bags containing the moss Sphagnum junghuhnianum were used to assess the concentrations of heavy metals (chromium (Cr, copper (Cu, lead (Pb, vanadium (V, and zinc (Zn at five sampling sites (four roads and a forest park during the summer and winter of 2012. According to the relative accumulation factor (RAF and contamination factor (CF results, pollution in winter was heavier than that in summer, and Cr was found to be the most contaminating, having the highest mean CF. There was a significant positive correlation (p < 0.05 between traffic volume and concentration for three heavy metals (Cr, Cu, and V in winter, whereas a significant positive correlation (p < 0.05 was observed between traffic volume and concentrations for four heavy metal elements (Cr, Pb, V, and Zn in summer, indicating a close relationship between heavy metal contents and traffic volume. Although there was substantial variation in the concentrations of the five heavy metals in the moss bags, significant correlations between heavy metals suggested that the contaminants originated from a common source, namely vehicle emissions. The results demonstrated that the four roads were subject to different degrees of pollution depending on the volume of traffic using each road. Therefore, the results of this study suggest that traffic volume is a major reason for heavy metal pollution.

  12. Environmental law and climate change : Volumes I & II

    NARCIS (Netherlands)

    Verschuuren, Jonathan

    Two volume set that brings together 54 of the most influential and important scientific journal articles in the field of climate law, thematically grouped together as follows: introducing climate law, theories and approaches, climate change mitigation, climate change adaptation, climate justice,

  13. Monitoring early response to anti-angiogenic therapy: diffusion-weighted magnetic resonance imaging and volume measurements in colon carcinoma xenografts.

    Directory of Open Access Journals (Sweden)

    Moritz Jörg Schneider

    Full Text Available OBJECTIVES: To evaluate the use of diffusion-weighted MRI (DW-MRI and volume measurements for early monitoring of antiangiogenic therapy in an experimental tumor model. MATERIALS AND METHODS: 23 athymic nude rats, bearing human colon carcinoma xenografts (HT-29 were examined before and after 6 days of treatment with regorafenib (n = 12 or placebo (n = 11 in a clinical 3-Tesla MRI. For DW-MRI, a single-shot EPI sequence with 9 b-values (10-800 s/mm2 was used. The apparent diffusion coefficient (ADC was calculated voxelwise and its median value over a region of interest, covering the entire tumor, was defined as the tumor ADC. Tumor volume was determined using T2-weighted images. ADC and volume changes between first and second measurement were evaluated as classifiers by a receiver-operator-characteristic (ROC analysis individually and combined using Fisher's linear discriminant analysis (FLDA. RESULTS: All ADCs and volumes are stated as median±standard deviation. Tumor ADC increased significantly in the therapy group (0.76±0.09×10(-3 mm2/s to 0.90±0.12×10(-3 mm2/s; p<0.001, with significantly higher changes of tumor ADC than in the control group (0.10±0.11×10(-3 mm2/s vs. 0.03±0.09×10(-3 mm2/s; p = 0.027. Tumor volume increased significantly in both groups (therapy: 347.8±449.1 to 405.3±823.6 mm3; p = 0.034; control: 219.7±79.5 to 443.7±141.5 mm3; p<0.001, however, the therapy group showed significantly reduced tumor growth (33.30±47.30% vs. 96.43±31.66%; p<0.001. Area under the curve and accuracy of the ADC-based ROC analysis were 0.773 and 78.3%; and for the volume change 0.886 and 82.6%. The FLDA approach yielded an AUC of 0.985 and an accuracy of 95.7%. CONCLUSIONS: Regorafenib therapy significantly increased tumor ADC after 6 days of treatment and also significantly reduced tumor growth. However, ROC analyses using each parameter individually revealed a lack of accuracy in discriminating between therapy and

  14. Fiber, Fabric and Fashion. Environment II.

    Science.gov (United States)

    Arizona State Univ., Tempe.

    A competency-based instructional guide for grades 7-14, this volume is one of three parts, each of which focuses on a different environment (psychomotor, cognitive, or affective), and each of which includes competencies and learning activities for each of three instructional levels. The topics for this volume (Environment II--cognitive) are…

  15. Site Environmental Report for 2009, Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Regina

    2010-08-17

    Each year, the University of California (UC), as the managing and operating contractor of the Ernest Orlando Lawrence Berkeley National Laboratory, prepares an integrated report regarding its environmental programs to satisfy the requirements of United States Department of Energy (DOE) Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2009 summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2009. Throughout this report, 'Berkeley Lab' or 'LBNL' refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that contain an overview of LBNL, a discussion of its environmental management system (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities. The Site Environmental Report is distributed by releasing it on the World Wide Web (Web) from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. Links to documents available on the Web are given with the citations in the References section. CD and printed copies of this Site Environmental Report are available upon request. The report follows Berkeley Lab's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible

  16. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Hecking Manfred

    2012-06-01

    Full Text Available Abstract Background Data generated with the body composition monitor (BCM, Fresenius show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR and/or regulation of ultrafiltration and temperature (UTR will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters, relative to extracellular water (ECW. In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW. Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase. In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study

  17. In Situ Monitoring and Modeling of the Solution-Mediated Polymorphic Transformation of Rifampicin: From Form II to Form I.

    Science.gov (United States)

    Guo, Nannan; Hou, Baohong; Wang, Na; Xiao, Yan; Huang, Jingjing; Guo, Yanmei; Zong, Shuyi; Hao, Hongxun

    2018-01-01

    In this article, the solution-mediated polymorphic transformation of rifampicin was investigated and simulated in 3 solvents at 30°C. The solid-state form I and form II of rifampicin was characterized by powder X-ray diffraction, scanning electron microscopy, thermogravimetric analysis, Raman spectroscopy, and Fourier transform infrared spectroscopy (FTIR). To explore the relative stability, solubility data of form I and form II of rifampicin in butan-1-ol were determined using a dynamical method. In addition, Raman spectroscopy and focused beam reflectance measurement were used to in situ monitor the transformation of rifampicin from form II to form I. The liquid state concentration of rifampicin was measured by UV spectroscopic method. To investigate the effect of solvent on transformation, the transformation experiments were carried out in 3 solvents. Furthermore, a mathematical model was built to describe the kinetics of dissolution, nucleation, and growth processes during transformation by using experimental data. By combination of experimental and simulation results, it was found that the transformation process of rifampicin is controlled by dissolution of form II in heptane, whereas the transformation in hexane and octane was firstly controlled by dissolution of solid-state form and then controlled by growth of form I. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. Influence of endoleaks on aneurysm volume and hemodynamics after endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Pitton, M.B.; Welter, B.; Schmenger, P.; Thelen, M.; Dueber, C.; Neufang, A.

    2003-01-01

    Purpose: To evaluate the aneurysm volume and the intra-aneurysmatic pressure and maximal pressure pulse (dp/dtmax) in completely excluded aneurysms and cases with endoleaks. Materials and Methods: In 36 mongrel dogs, experimental autologous aneurysms were treated with stent-grafts. All aortic side branches were ligated in 18 cases (group I) but were preserved in group II (n=18). Aneurysm volumes were calculated from CT scans before and after intervention, and from follow-up CT scans at 1 week, 6 weeks and 6 months. Finally, for hemodynamic measurements, manometer-tipped catheters were introduced into the excluded aneurysm sac (group I and II), selectively in endoleaks (group II), and intraluminally for aortic reference measurement. Systemic hypertension was induced by volume load and pharmacologic stress. Pressure curves and dp/dt were simultaneously recorded and the ratios of aneurysm pressure to systemic reference pressure calculated. Results: At follow-up, type-II, endoleaks were excluded in all cases of group I by selective angiography. In contrast, endoleaks were evident in all cases of group II. Volumetric analysis of the aneurysms showed a benefit for group I with an improved aneurysm shrinkage: ΔVolume +0.08%, -1.62% and -9.76% at 1 week, 6 weeks and 6 months follow-up (median, group I), compared to +1.43%, +0.67%, and -4.04% (group II), p [de

  19. Adsorption efficiencies of calcium (II ion and iron (II ion on activated carbon obtained from pericarp of rubber fruit

    Directory of Open Access Journals (Sweden)

    Orawan Sirichote

    2008-03-01

    Full Text Available Determination of adsorption efficiencies of activated carbon from pericarp of rubber fruit for calcium (II ion and iron (II ion has been performed by flowing the solutions of these ions through a column of activated carbon. The weights of activated carbon in 500 mL buret column (diameter 3.2 cm for flowing calcium (II ion and iron (II ion solutions were 15 g and 10 g, respectively. The initial concentration of calcium ion was prepared to be about eight times more diluted than the true concentration found in the groundwater from the lower part of southern Thailand. Calcium (II ion concentrations were analysed by EDTA titration and its initial concentration was found to be 23.55 ppm. With a flow rate of 26 mL/min, the adsorption efficiency was 11.4 % with passed through volume 4.75 L. Iron (II ion concentrations were analysed by spectrophotometric method; its initial concentration was found to be 1.5565 ppm. At a flow rate of 22 mL/min, the adsorption efficiency was 0.42 % with passed through volume of 34.0 L.

  20. A beam monitor using silicon pixel sensors for hadron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhen, E-mail: zwang@mails.ccnu.edu.cn; Zou, Shuguang; Fan, Yan; Liu, Jun; Sun, Xiangming, E-mail: sphy2007@126.com; Wang, Dong; Kang, Huili; Sun, Daming; Yang, Ping; Pei, Hua; Huang, Guangming; Xu, Nu; Gao, Chaosong; Xiao, Le

    2017-03-21

    We report the design and test results of a beam monitor developed for online monitoring in hadron therapy. The beam monitor uses eight silicon pixel sensors, Topmetal-II{sup -}, as the anode array. Topmetal-II{sup -} is a charge sensor designed in a CMOS 0.35 µm technology. Each Topmetal-II{sup -} sensor has 72×72 pixels and the pixel size is 83×83 µm{sup 2}. In our design, the beam passes through the beam monitor without hitting the electrodes, making the beam monitor especially suitable for monitoring heavy ion beams. This design also reduces radiation damage to the beam monitor itself. The beam monitor is tested with a carbon ion beam at the Heavy Ion Research Facility in Lanzhou (HIRFL). Results indicate that the beam monitor can measure position, incidence angle and intensity of the beam with a position resolution better than 20 µm, angular resolution about 0.5° and intensity statistical accuracy better than 2%.

  1. Seymour Benzer and T4 rII

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 13; Issue 10. Seymour Benzer and T4 rII - Running the Map into the Ground. R Jayaraman. General Article Volume 13 Issue 10 October 2008 pp 898-908. Fulltext. Click here to view fulltext PDF. Permanent link:

  2. Environmental monitoring survey of oil and gas fields in Region II in 2009. Summary report; Miljoeovervaaking av olje- og gassfelt i Region II i 2009

    Energy Technology Data Exchange (ETDEWEB)

    2010-03-15

    The oil companies Statoil ASA, ExxonMobil Exploration and Production Norway AS, Total E&P Norge AS, Talisman Energy Norge AS and Marathon Petroleum Norge AS commissioned Section of Applied Environmental Research at UNI RESEARCH AS to undertake the monitoring survey of Region II in 2009. Similar monitoring surveys in Region II have been carried out in 1996, 2000, 2003 and 2006. The survey in 2009 included in total 18 fields: Rev, Varg, Sigyn, Sleipner Vest, Sleipner OEst, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Vale, Skirne, Byggve, Heimdal, Volve, Vilje og Alvheim. Sampling was conducted from the vessel MV Libas between May 18 and May 27. Samples were collected from in totally 137 sampling sites, of which 15 were regional sampling sites. Samples for chemical analysis were collected at all sites, whereas samples for benthos analysis were collected at 12 fields. As in previous surveys, Region II is divided into natural sub-regions. One sub-region is shallow (77-96 m) sub-region, a central sub-region (107-130 m) and a northern subregion (115-119 m). The sediments of the shallow sub-region had relatively lower content of TOM and pelite and higher content of fine sand than the central and northern sub-regions. Calculated areas of contamination are shown for the sub-regions in Table 1.1. The fields Sigyn, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Skirne, Byggve, Vilje og Alvheim showed no contamination of THC. At the other fields there were minor changes from 2006. The concentrations of barium increased in the central sub-region from 2006 to 2009, also at fields where no drilling had been undertaken during the last years. The same laboratory and methods are used during the three last regional investigations. The changes in barium concentrations may be due to high variability of barium concentrations in the sediments. This is supported by relatively large variations in average barium concentrations at the regional sampling sites in

  3. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  4. Guidelines for personal exposure monitoring of chemicals: Part II.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2017-11-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  5. Lanchester-Type Models of Warfare. Volume II

    Science.gov (United States)

    1980-10-01

    ii7 L HOWES and THRALL (1972) ,HT n HTY HT m HTX jini ijl HOLTER (1973) and ANDERSON (1979) CHA HAx Y tAs in the preceding table, SPUDICH (1968) - the...detail can one afford? A recent U. S. General Accounting Office ( GAO ) report [150, pp. 28-29] points out that there is a strong inconsistency between...further details). 65. A recent U. S. Getueral Accounting Office ( GAO ) [1501 study has emphasized that empirical study is necessary to strengthen the

  6. Increased mean platelet volume in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Ezgi Coşkun Yenigün

    2014-03-01

    Full Text Available Objective: Platelet functions have important roles in the development of vascular complications in diabetic patients. Platelets with increased volume have increased activity compared to smaller ones; therefore, mean platelet volume (MPV is used as a marker for platelet activity. In the present study, we evaluated MPV in patients with type II diabetes mellitus (DM and its associations with diabetic microvascular and macrovascular complications. Methods: Consecutive type II diabetic patients were screened from outpatient clinic of Internal Medicine Department of Diskapı Yıldırım Beyazıt Education and Researsch Hospital, Ankara, Turkey. A total of 48 patients with type II DM and 30 age and gender matched healthy subjects constituted the study population. For all subjects a complete blood count including MPV, fasting blood glucose level and lipid parameters were studied. In diabetic patients, duration of diabetes and HbA1C level, presence of microvascular and macrovascular complications were noted additively. Mean platelet volume was compared between diabetic patients and healthy counterparents. Then, among diabetic patients, MPV was compared between the ones with and without microvascular and macrovascular complications. Results: Mean platelet volume was found significantly higher in diabetic patients compared to non-diabetic healthy subjects. Diabetic patients with at least one of the microvascular complications had significantly higher MPV than those without microvascular damage.Higher MPV levels have also been shown in diabetics with macrovascular complications compared to the ones without macrovascular disease. Conclusion: Mean platelet volume was found to be higher in type II diabetics and those having any of microvascular or macrovascular diabetic complications.

  7. Electric power annual 1994. Volume 2, Operational and financial data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-28

    This year, the annual is published in two volumes. Volume I focused on US electric utilities and contained final 1994 data on net generation, fossil fuel consumption, stocks, receipts, and cost. This Volume II presents annual 1994 summary statistics for the electric power industry, including information on both electric utilities and nonutility power producers. Included are preliminary data for electric utility retail sales of electricity, associated revenue, and average revenue per kilowatthour of electricity sold (based on form EIA-861) and for electric utility financial statistics, environmental statistics, power transactions, and demand- side management. Final 1994 data for US nonutility power producers on installed capacity and gross generation, as well as supply and disposition information, are also provided in Volume II. Technical notes and a glossary are included.

  8. OPSATCOM Field Measurements. Volume II. Supplemental Information

    Science.gov (United States)

    1976-06-01

    7-5 y 4, Solar monitor ............. ........................... 7-6 5. Deck ceill ...phatomnultiplier tube to be non-propnrtional to the total flux, if different areas of the photocathode are used. Underwater Lensess The amount of glass and...Parallel optical glass windows, The requirements for strength, low scat- tating end achromatization dictated lens requirements that could be met only by

  9. 21 CFR 868.2450 - Lung water monitor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lung water monitor. 868.2450 Section 868.2450 Food... DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2450 Lung water monitor. (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by...

  10. Bunch arrival time monitors; Concepts towards improving the sensitivity for low charge operation for FLASH II and XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Penirschke, Andreas; Angelovski, Aleksandar; Jakoby, Rolf [TU Darmstadt, Institut fuer Mikrowellentechnik und Photonik, Merckstr. 25, 64283 Darmstadt (Germany); Sydlo, Cezary; Bousonville, Michael; Czwalinna, Marie Kristin; Schlarb, Holger [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Kuhl, Alexander [University of Hamburg, Physics Department, Accelerator Physics Group (Germany); Weiland, Thomas [Technische Univ. Darmstadt (Germany). Inst. fuer Theorie Elektromagnetischer Felder

    2013-07-01

    High gain Free-Electron Lasers can generate ultra short X-ray pulses in the femtosecond range. For a stable operation of the FEL, the precise knowledge of the bunch arrival time is crucial. A novel high bandwidth Bunch Arrival time Monitor was recently installed at FLASH to allow a low charge operation mode with a sub-10 fs resolution for bunch charges of 20 pC or more. The BAM is equipped with cone shaped pickups for the precise measurement of both, the high and low bunch charge operation mode. For the extension of FLASH facility to FLASH II new pickups for the high bandwidth BAMs need to be developed. The new BAM needs to maximize the voltage level of the beam induced signal for low charge operation mode in order to provide sufficient signal strength for the subsequent electronics. In this talk, we present concepts to improve the signal strength at the electro-optic modulators for low charge operation at FLASH II and XFEL.

  11. Environmental monitoring survey of oil and gas fields in Region II in 2009. Summary report; Miljoeovervaaking av olje- og gassfelt i Region II i 2009. Sammendragsrapport

    Energy Technology Data Exchange (ETDEWEB)

    2010-03-15

    The oil companies Statoil ASA, ExxonMobil Exploration and Production Norway AS, Total E&P Norge AS, Talisman Energy Norge AS and Marathon Petroleum Norge AS commissioned Section of Applied Environmental Research at UNI RESEARCH AS to undertake the monitoring survey of Region II in 2009. Similar monitoring surveys in Region II have been carried out in 1996, 2000, 2003 and 2006. The survey in 2009 included in total 18 fields: Rev, Varg, Sigyn, Sleipner Vest, Sleipner Oest, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Vale, Skirne, Byggve, Heimdal, Volve, Vilje og Alvheim. Sampling was conducted from the vessel MV Libas between May 18 and May 27. Samples were collected from in totally 137 sampling sites, of which 15 were regional sampling sites. Samples for chemical analysis were collected at all sites, whereas samples for benthos analysis were collected at 12 fields. As in previous surveys, Region II is divided into natural sub-regions. One sub-region is shallow (77-96 m) sub-region, a central sub-region (107-130 m) and a northern subregion (115-119 m). The sediments of the shallow sub-region had relatively lower content of TOM and pelite and higher content of fine sand than the central and northern sub-regions. Calculated areas of contamination are shown for the sub-regions in Table 1.1. The fields Sigyn, Sleipner Alfa Nord, Glitne, Grane, Balder, Ringhorne, Jotun, Skirne, Byggve, Vilje og Alvheim showed no contamination of THC. At the other fields there were minor changes from 2006. The concentrations of barium increased in the central sub-region from 2006 to 2009, also at fields where no drilling had been undertaken during the last years. The same laboratory and methods are used during the three last regional investigations. The changes in barium concentrations may be due to high variability of barium concentrations in the sediments. This is supported by relatively large variations in average barium concentrations at the regional sampling sites in

  12. Calibration of a large volume argon-41 gas-effluent monitor

    International Nuclear Information System (INIS)

    Wilson, William E.; Lovas, Thomas A.

    1976-01-01

    In September of 1975, a large volume Argon-41 sampler was calibrated using a series connected calibration chamber of known sensitivity and a constant flow of activated Argon gas. The calibration included analysis of the effects of flow rate through the large volume sampler and yielded a calibration constant of 2.34 x 10 -8 μc/cm 3 /CPM. (author)

  13. Comprehensive Cooling Water Study. Volume 1. Summary of environmental effects, Savannah River Plant. Annual report

    International Nuclear Information System (INIS)

    Gladden, J.B.; Lower, M.W.; Mackey, H.E.; Specht, W.L.; Wilde, E.W.

    1985-07-01

    This volume summarizes the technical content of Volumes II through XI of the annual report. Volume II provides a description of the SRP environment, facilities, and operation, and presents the objectives and design for the CCWS. Volume III presents information on water quality of SRP surface waters. Results of radionuclide and heavy metal transport studies are presented in Volume IV. Volume V contains findings from studies of wetland plant communities. Volume VI presents findings from studies of the lower food chain components of SRP aquatic habitats. The results of fisheries studies are reported in Volume VII. Studies of semi-aquatic vertebrate populations are reported in Volume VIII. Water-fowl utilization of SRP habitats is discussed in Volume IX. The status of endangered species that utilize SRP aquatic habitats is presented in Volume X. The findings from studies of Parr Pond ecosystem are presented in Volume XI

  14. SLSF loop handling system. Volume I. Structural analysis

    International Nuclear Information System (INIS)

    Ahmed, H.; Cowie, A.; Ma, D.

    1978-10-01

    SLSF loop handling system was analyzed for deadweight and postulated dynamic loading conditions, identified in Chapters II and III in Volume I of this report, using a linear elastic static equivalent method of stress analysis. Stress analysis of the loop handling machine is presented in Volume I of this report. Chapter VII in Volume I of this report is a contribution by EG and G Co., who performed the work under ANL supervision

  15. Monitoring tidal volumes in preterm infants at birth: mask versus endotracheal ventilation.

    Science.gov (United States)

    van Vonderen, Jeroen J; Hooper, Stuart B; Krabbe, Vera B; Siew, Melissa L; Te Pas, Arjan B

    2015-01-01

    Upper airway distention during mask ventilation could reduce gas volumes entering the lung compared with ventilation via an endotracheal tube. Therefore, respiratory tract volumes were measured in lambs and tidal volumes were compared in preterm infants before and after intubation. In seven preterm lambs, volumes of the airways (oropharynx, trachea, lungs) were assessed. In 10 preterm infants, delta pressures, tidal volumes and leak were measured during ventilation 2 min before (mask ventilation) and 2 min after intubation (endotracheal ventilation). Inflations coinciding with breaths were excluded. Amount of upper airway distention in lambs and differences in inspiratory and expiratory tidal volume before and after intubation. In lambs, the combined trachea and oropharynx contributed to 14 (12-21) % (median (IQR), whereas the oropharynx contributed to 9 (7-10) % of the total tidal volume measured at the mouth. In preterm infants, inspiratory (11.1 (7.9-22.6) mL/kg vs 5.8 (3.9-9.6) mL/kg (p=0.01)) and expiratory (8.3 (6.8-15.4) mL/kg vs 4.9 (3.9-9.6) mL/kg (p=0.02)) tidal volumes were significantly larger during mask ventilation compared with endotracheal ventilation. Leak was 18.7 (3.3-28.7) % before versus 0 (0-2.3) % after intubation (p0.05). During mask ventilation, expiratory tidal volume increased from 10.0 (5.4-15.6) mL/kg to 11.3 (7.6-17.0) mL/kg (p=0.01), but remained unchanged during endotracheal ventilation. During neonatal mask ventilation, distention of the upper respiratory tract contributes to the tidal volumes measured and should be taken into account when targeting tidal volumes during mask ventilation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Cacotheline as an oxidimetric reagent. Determination of Sn(II), Cu(I), Ti(III), Fe(II), V(II) and V(III)

    International Nuclear Information System (INIS)

    Nemani Murty, K.; Yedluri Rao, P.; Geddada Chalam, K.

    1982-01-01

    Sn(II), Ti(III), Cu(I),Fe(II), V(III) and V(II) can be titrated potentiometrically with cacotheline in 1-4 M hydrochloric acid, 0.5-2 M hydrochloric acid, 0.5-1.5 M sulphuric acid in presence of 4 ml of 10% EDTA solution in a total volume of 50 ml, 9-10 M phosphoric acid, 4-8 M acetic acid and 3-8 M acetic acid respectively. Cacotheline can be used for the assay of tin plate and solder. The cacotheline undergoes a 2-electron reduction reaction. A cacotheline solution (0.005 M) in 0.02 M hydrochloric acid is fairly stable for several months. The conditional redox potentials of cacotheline have been determined in sulphuric, phosphoric and acetic acid medium. (Author)

  17. Reactor Emergency Action Level Monitor: Volume 2, REALM user's reference guide: Final report

    International Nuclear Information System (INIS)

    Touchton, R.A.

    1988-09-01

    A User Manual for the Reactor Emergency Action Level Monitor (REALM) expert system prototype is provided in this volume. REALM has been designed to provide expert assistance in the identification of a nuclear power plant emergency situation and the determination of its severity. REALM has been developed as an expert system which can provide sensor interpretation and situation assessment in a real-time processing environment. In its state of development at project completion, these capabilities are used in an off-line (i.e., stand-alone, desktop) fashion to provide emergency preparedness assistance in the areas of emergency classification training and emergency exercise scenario generation. REALM also serves a prototype and stepping-stone for the possible connection to the plant for on-line use. In order to distinguish the off-line system (now complete) from the on-line system (now moving from a research prototype to an installed system), the term ''REALM'' is used to indicate the on-line version, with users in the control room, technical support center, and the emergency operations facility, The off-line version is referred to as ''uREALM.''

  18. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  19. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  20. Sodium technology at EBR-II

    International Nuclear Information System (INIS)

    Holmes, J.T.; Smith, C.R.F.; Olson, W.H.

    1976-01-01

    Since the installation of purity monitoring systems in 1967, the control of the purity of the primary and secondary sodium and cover gas systems at the Experimental Breeder Reactor II (EBR-II) has been excellent. A rigorous monitoring program is being used to assure that operating limits for more than 25 chemical and radioactive impurities are not exceeded. The program involves the use of sophisticated sampling and analysis techniques and on-line monitors for both sodium and cover gas systems. Sodium purity control is accomplished by essentially continuous cold trapping of a small side stream of the total circulating sodium. The cold traps have been found to be very effective for the removal of the major chemical impurities (oxygen and hydrogen) and tritium but are almost ineffective for 131 I and 137 Cs that enter the sodium from fuel cladding breaks. Purging with pure argon maintains the cover gas purity

  1. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 2: Test Bed Performance Evaluation and Final AeroMACS Recommendations

    Science.gov (United States)

    Hall, Edward; Magner, James

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II (this document) describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  2. International Photovoltaic Program Plan. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Costello, D.; Koontz, R.; Posner, D.; Heiferling, P.; Carpenter, P.; Forman, S.; Perelman, L.

    1979-12-01

    This second volume of a two-part report on the International Photovoltaic Program Plan contains appendices summarizing the results of analyses conducted in preparation of the plan. These analyses include compilations of relevant statutes and existing Federal programs; strategies designed to expand the use of photovoltaics abroad; information on the domestic photovoltaic plan and its impact on the proposed international plan; perspectives on foreign competition; industry views on the international photovoltaic market and ideas about how US government actions could affect this market; international financing issues; and information on issues affecting foreign policy and developing countries.

  3. Energy Extension Service Pilot Program: evaluation report after two years. Volume II. State reports

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-04-01

    This report, Vol. II, presents a discussion of the operations of the ten EES pilot state programs during the period from October 1, 1977 through September 30, 1979. Each of the ten pilot states - Alabama, Connecticut, Michigan, New Mexico, Pennsylvania, Tennessee, Texas, Washington, Wisconsin, and Wyoming - received a grant of approximately $1.1 million to develop and implement an 18-month program beginning on October 1, 1977. In September 1978, each State received an additional $370,000 for service-delivery programs for the extension of the pilot program, April 1979 through September 1979. A case-study description of the operations of the pilot program in each State is provided here, with special attention given to the two programs selected in each State for more-detailed study and survey research. Although the thrust of this volume is descriptive, some survey data and analyses are presented for the emphasis programs. Two telephone surveys of clients and a non-client sample were conducted, one at the end of the first year of the pilot program (October 1977 - September 1978) and one at the end of the second year (October 1978 - September 1979).

  4. SEPARATION OF Fe (III, Cr(III, Cu(II, Ni(II, Co(II, AND Pb(II METAL IONS USING POLY(EUGENYL OXYACETIC ACID AS AN ION CARRIER BY A LIQUID MEMBRANE TRANSPORT METHOD

    Directory of Open Access Journals (Sweden)

    La Harimu

    2010-06-01

    Full Text Available Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II  metal ions had been separated using poly(eugenyl oxyacetic acid as an ion carrier by bulk liquid membrane transport method. The effect of pH, polyeugenyl oxyacetic acid ion carrier concentration, nitric acid concentration in the stripping solution, transport time, and metal concentration were optimized. The result showed that the optimum condition for transport of metal ions was at pH 4 for ion Fe(III and at pH 5 for Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions. The carrier volumes were optimum with concentration of 1 x 10-3 M at 7.5 mL for Cr(III, Cu (II,  Ni(II, Co(II ions and at 8.5 mL for Fe(III and Pb(II ions. The concentration of HNO3 in stripping phase was optimum at 2 M for Fe(III and Cu(II ions, 1 M for Cr(III, Ni(II and Co(II ions, and 0.5 M for Pb(II ion. The optimum transport times were 36 h for Fe(III and Co(II ions, and 48 h for Cr(III, Cu (II, Ni(II, and Pb(II ions. The concentration of metal ions accurately transported were 2.5 x 10-4 M for Fe(III and Cr(III ions, and 1 M for Cu (II, Ni(II, Co(II, and Pb(II ions. Compared to other metal ions the transport of Fe(III was the highest with selectivity order of Fe(III > Cr(III > Pb(II > Cu(II > Ni(II > Co(II. At optimum condition, Fe(III ion was transported through the membrane at 46.46%.   Keywords: poly(eugenyl oxyacetic acid, transport, liquid membrane, Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions

  5. Self-dual nonsupersymmetric Type II String Compactifications

    International Nuclear Information System (INIS)

    Kachru, Shamit; Silverstein, Eva

    1998-01-01

    It has recently been proposed that certain nonsupersymmetric type II orbifolds have vanishing perturbative contributions to the cosmological constant. We show that techniques of Sen and Vafa allow one to construct dual type II descriptions of these models (some of which have no weakly coupled heterotic dual). The dual type II models are given by the same orbifolds with the string coupling S and a T 2 volume T exchanged. This allows us to argue that in various strongly coupled limits of the original type II models, there are weakly coupled duals which exhibit the same perturbative cancellations as the original models

  6. Unit Monitors Manchester-Format Data Buses

    Science.gov (United States)

    Amador, Jose J.

    1994-01-01

    Circuit card converts data signals into convenient hexadecimal form for troubleshooting. Bus-monitoring unit converts data signals from Manchester II format used on data bus into hexadecimal format. Monitoring circuit causes hexadecimal words to display on video terminal, where test engineer compares them with hexadecimal records for troubleshooting. Circuit monitors one bus or two buses simultaneously.

  7. Fusion Engineering Device. Volume II. Design description

    International Nuclear Information System (INIS)

    1981-10-01

    This volume summarizes the design of the FED. It includes a description of the major systems and subsystems, the supporting plasma design analysis, a projected device cost and associated construction schedule, and a description of the facilities to house and support the device. This effort represents the culmination of the FY81 studies conducted at the Fusion Engineering Design Center (FEDC). Unique in these design activities has been the collaborative involvement of the Design Center personnel and numerous resource physicists from the fusion community who have made significant contributions in the physics design analysis as well as the physics support of the engineering design of the major FED systems and components

  8. Monitoring Heavy Metal Contents with Sphagnum Junghuhnianum Moss Bags in Relation to Traffic Volume in Wuxi, China.

    Science.gov (United States)

    Hu, Rong; Yan, Yun; Zhou, Xiaoli; Wang, Yanan; Fang, Yanming

    2018-02-22

    Despite its small size, a moss bag can reveal the different temporal and spatial deposition patterns of pollutants at a particular site; therefore, researchers can use moss bags to determine pollution sources and to put forward strategies for pollution control. Although the use of moss bags to monitor atmospheric pollution has been widely reported in Europe, there are few such empirical studies in China. Thus, in this study, bags containing the moss Sphagnum junghuhnianum were used to assess the concentrations of heavy metals (chromium (Cr), copper (Cu), lead (Pb), vanadium (V), and zinc (Zn)) at five sampling sites (four roads and a forest park) during the summer and winter of 2012. According to the relative accumulation factor (RAF) and contamination factor (CF) results, pollution in winter was heavier than that in summer, and Cr was found to be the most contaminating, having the highest mean CF. There was a significant positive correlation ( p heavy metals (Cr, Cu, and V) in winter, whereas a significant positive correlation ( p heavy metal elements (Cr, Pb, V, and Zn) in summer, indicating a close relationship between heavy metal contents and traffic volume. Although there was substantial variation in the concentrations of the five heavy metals in the moss bags, significant correlations between heavy metals suggested that the contaminants originated from a common source, namely vehicle emissions. The results demonstrated that the four roads were subject to different degrees of pollution depending on the volume of traffic using each road. Therefore, the results of this study suggest that traffic volume is a major reason for heavy metal pollution.

  9. Eleventh annual Department of Energy low-level waste management conference. Volume 2: Low-level waste strategy and planning, decontamination and decommissioning, compliance monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-11-01

    Nineteen papers are presented in volume 2. The 11 papers in the LLW Strategy and Planning section discuss plans for disposal facilities in Texas, Pennsylvania, Hanford, the Southwest and Southeast Compacts, and others. Three papers discuss decontamination technology and activities. Environmental monitoring requirements and recommendations at LLW facilities are discussed in 5 papers. Papers have been processed separately for inclusion on the data base.

  10. Volume changes and electrostriction in the primary photoreactions of various photosynthetic systems: estimation of dielectric coefficient in bacterial reaction centers and of the observed volume changes with the Drude-Nernst equation.

    Science.gov (United States)

    Mauzerall, David; Hou, Jian-Min; Boichenko, Vladimir A

    2002-01-01

    Photoacoustics (PA) allows the determination of enthalpy and volume changes of photoreactions in photosynthetic reaction centers on the 0.1-10 mus time scale. These include the bacterial centers from Rb. sphaeroides, PS I and PS II centers from Synechocystis and in whole cells. In vitro and in vivo PA data on PS I and PS II revealed that both the volume change (-26 A(3)) and reaction enthalpy (-0.4 eV) in PS I are the same as those in the bacterial centers. However the volume change in PS II is small and the enthalpy far larger, -1 eV. Assigning the volume changes to electrostriction allows a coherent explanation of these observations. One can explain the large volume decrease in the bacterial centers with an effective dielectric coefficient of approximately 4. This is a unique approach to this parameter so important in estimation of protein energetics. The value of the volume contraction for PS I can only be explained if the acceptor is the super- cluster (Fe(4)S(4))(Cys(4)) with charge change from -1 to -2. The small volume change in PS II is explained by sub-mus electron transfer from Y(Z) anion to P(680) cation, in which charge is only moved from the Y(Z) anion to the Q(A) with no charge separation or with rapid proton transfer from oxidized Y(Z) to a polar region and thus very little change in electrostriction. At more acid pH equally rapid proton transfer from a neighboring histidine to a polar region may be caused by the electric field of the P(680) cation.

  11. HIBAL Program. Preliminary Warhead-Design. Volume II. Appendices.

    Science.gov (United States)

    1980-09-15

    Mild Steel (iAi i018). ............. 11-2 B. SAE 4130 .. .. .. .... ...... ....... 11-3 C. SAE 4140 ......... .... .... ......... 11-3 D, SAE 4340...11-7 - Test Data for SAE 4140 Steel Frag- ments ...... ................ 11-14 Figure II-7A - 4142 ... .............. 11-15 Figure 11-8 - Test Data...included the following types of steel: SAE 1018, 4130, 4140 and 4340; 5-317 and 5-876 Carpenter tool steel; Anico HY-80 and SSS-100 steel; AISI-S7

  12. Development of a portable analyzer with polymer lab-on-a-chip (LOC) for continuous sampling and monitoring of Pb(II).

    Science.gov (United States)

    Jang, A; Zou, Z; MacKnight, E; Wu, P M; Kim, I S; Ahn, C H; Bishop, P L

    2009-01-01

    A new portable analyzer with polymer lab-on-a-chip (LOC) has been designed, fabricated and fully characterized for continuous sampling and monitoring of lead (Pb(II)) in this work. As the working electrodes of the sensor, bismuth (Bi (III)) which allowed the advantage of being more environmentally friendly than traditional mercury drop electrodes was used, while maintaining similar sensitivity and other desirable characteristics. The size of a portable analyzer was 30 cmx23 cmx7 cm, and the weight was around 3 kg. The small size gives the advantage of being portable for field use while not sacrificing portability for accuracy of measurement. Furthermore, the autonomous system developed in coordination with the development of new polymer LOC integrated with electrochemical sensors can provide an innovative way to monitor surface waters in an efficient, cost-effective and sustainable manner.

  13. Fiscal year 1985 Department of Energy authorization (high-energy and nuclear physics). Volume II-B. Hearing before the Subcommittee on Energy Development and Applications of the Committee on Science and Technology, US House of Representatives, Ninety-Eighth Congress, Second Session, February 22, 1984

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Volume II-B of the DOE authorization hearings for fiscal year 1985 covers testimony on high-energy and nuclear physics programs. The volume opens with a continuation of Appendix I, which contains questions directed at Dr. Alvin Trivelpiece and his responses on research at several laboratories and four construction projects. The latter include general plant projects, the Continuous Electron Beam Accelerator Facility, the Tandem/AGS Heavy Ion Transfer Line, and the University Accelerator Upgrade at the University of Washington and Yale. Two 1983 DOE/National Science Foundation reports make up Appendix II. The volume concludes with the text of the 1985 budget request for $746,105,000 and a breakdown of line item expenditures

  14. Retrospective Methods Analysis of Semiautomated Intracerebral Hemorrhage Volume Quantification From a Selection of the STICH II Cohort (Early Surgery Versus Initial Conservative Treatment in Patients With Spontaneous Supratentorial Lobar Intracerebral Haematomas).

    Science.gov (United States)

    Haley, Mark D; Gregson, Barbara A; Mould, W Andrew; Hanley, Daniel F; Mendelow, Alexander David

    2018-02-01

    The ABC/2 method for calculating intracerebral hemorrhage (ICH) volume has been well validated. However, the formula, derived from the volume of an ellipse, assumes the shape of ICH is elliptical. We sought to compare the agreement of the ABC/2 formula with other methods through retrospective analysis of a selection of the STICH II cohort (Early Surgery Versus Initial Conservative Treatment in Patients With Spontaneous Supratentorial Lobar Intracerebral Haematomas). From 390 patients, 739 scans were selected from the STICH II image archive based on the availability of a CT scan compatible with OsiriX DICOM viewer. ICH volumes were calculated by the reference standard semiautomatic segmentation in OsiriX software and compared with calculated arithmetic methods (ABC/2, ABC/2.4, ABC/3, and 2/3SC) volumes. Volumes were compared by difference plots for specific groups: randomization ICH (n=374), 3- to 7-day postsurgical ICH (n=206), antithrombotic-associated ICH (n=79), irregular-shape ICH (n=703) and irregular-density ICH (n=650). Density and shape were measured by the Barras ordinal shape and density groups (1-5). The ABC/2.4 method had the closest agreement to the semiautomatic segmentation volume in all groups, except for the 3- to 7-day postsurgical ICH group where the ABC/3 method was superior. Although the ABC/2 formula for calculating elliptical ICH is well validated, it must be used with caution in ICH scans where the elliptical shape of ICH is a false assumption. We validated the adjustment of the ABC/2.4 method in randomization, antithrombotic-associated, heterogeneous-density, and irregular-shape ICH. URL: http://www.isrctn.com/ISRCTN22153967. Unique identifier: ISRCTN22153967. © 2018 American Heart Association, Inc.

  15. Chemically modified activated carbon with 1-acylthiosemicarbazide for selective solid-phase extraction and preconcentration of trace Cu(II), Hg(II) and Pb(II) from water samples.

    Science.gov (United States)

    Gao, Ru; Hu, Zheng; Chang, Xijun; He, Qun; Zhang, Lijun; Tu, Zhifeng; Shi, Jianping

    2009-12-15

    A new sorbent 1-acylthiosemicarbazide-modified activated carbon (AC-ATSC) was prepared as a solid-phase extractant and applied for removing of trace Cu(II), Hg(II) and Pb(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 3, the maximum static adsorption capacity of Cu(II), Hg(II) and Pb(II) onto the AC-ATSC were 78.20, 67.80 and 48.56 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 3.0 mL of 2% CS(NH2)2 and 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3sigma) of this method for Cu(II), Hg(II) and Pb(II) were 0.20, 0.12 and 0.45 ng mL(-1), respectively. The relative standard deviation under optimum conditions is less than 4.0% (n=8). The prepared sorbent was applied for the preconcentration of trace Cu(II), Hg(II) and Pb(II) in certified and water samples with satisfactory results.

  16. Kempe's engineers year-book for 1977. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    Prockter, C.E. (ed.)

    1977-01-01

    The second volume of this two-volume yearbook contains data on: electrical and electronic engineering; aerodynamics and aircraft propulsion; gas turbines; internal combustion engines; motor vehicles; fuels; fluidics; nuclear energy; gas and gas engineering; steam engineering and steam turbines; marine diesel engines; naval architecture; mining engineering; industrial explosives; air compression, pneumatic equipment, etc.; refrigeration, heating, ventilation and air conditioning; lighting; industrial safety and protection; fire protection; highway engineering; surveying; foundation and earthwork; cements, mortars and clay products; buildings; public health engineering; concretes; design of steel structures; bridges and bridgework; paints and coatings; patents, designs and trade marks; depreciation; legal notes for engineers; factory planning and layout; and agricultural engineering. (1325p.) A subject index is provided. (LCL)

  17. First plasmas in the TJ-II flexible Heliac

    International Nuclear Information System (INIS)

    Alejaldre, C.; Alonso, J.; Almoguera, L.

    1999-01-01

    First plasmas have been successfully achieved in the TJ-II stellarator using electron cyclotron resonance heating (f = 53.2 GHz, P ECRH = 250 kW). Initial experiments have explored the TJ-II flexibility in a wide range of plasma volumes, different rotational transform and magnetic well values. In this paper, the main results of this campaign are presented and, in particular, the influence of plasma wall interaction phenomena on TJ-II operation is discussed briefly. (author)

  18. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP.

  19. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume 1. Program summary

    International Nuclear Information System (INIS)

    1979-12-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. This introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings and recommendations. Each of Volumes II-VII reports on an individual assessment (Volume II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP

  20. Prediction of acute cardiac rejection by changes in left ventricular volumes

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.K.; Boniaszczuk, J.

    1988-01-01

    Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection

  1. Colorado Conference on iterative methods. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The conference provided a forum on many aspects of iterative methods. Volume I topics were:Session: domain decomposition, nonlinear problems, integral equations and inverse problems, eigenvalue problems, iterative software kernels. Volume II presents nonsymmetric solvers, parallel computation, theory of iterative methods, software and programming environment, ODE solvers, multigrid and multilevel methods, applications, robust iterative methods, preconditioners, Toeplitz and circulation solvers, and saddle point problems. Individual papers are indexed separately on the EDB.

  2. Beneficiation-hydroretort processing of US oil shales: Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    None

    1989-01-01

    This report has been divided into three volumes. Volume I describes the MRI beneficiation work. In addition, Volume I presents the results of joint beneficiation-hydroretorting studies and provides an economic analysis of the combined beneficiation-hydroretorting approach for processing Eastern oil shales. Volume II presents detailed results of hydroretorting tests made by HYCRUDE/IGT on raw and beneficiated oil shales prepared by MRI. Volume III comprises detailed engineering design drawings and supporting data developed by the Roberts and Schaefer Company, Engineers and Contractors, Salt Lake City, Utah, in support of the capital and operating costs for a conceptual beneficiation plant processing an Alabama oil shale.

  3. Activity measurements at a waste volume reduction facility

    International Nuclear Information System (INIS)

    Richardson, J.; Lee, D.A.

    1979-01-01

    The monitoring program for Ontario Hydro's radioactive waste management site will be described, several aspects of which will be discussed in detail. The program at this facility includes categorization, volume reduction processing, and storage of solid radioactive wastes from nuclear generating stations of the CANDU type. At the present time, two types of volume reduction process are in operation - incineration and compaction. Following categorization and processing, wastes are stored in in-ground concrete trenches or tile-holes, or in above-ground quadricells. The monitoring program is divided into three areas: public safety, worker safety, and structural integrity. Development projects with respect to the monitoring program have been undertaken to achieve activity accounting for the total waste management program. In particular, a field measurement for the radioactivity content of radioactive ash containers and compacted waste drums

  4. Mapping the brain in type II diabetes: Voxel-based morphometry using DARTEL

    International Nuclear Information System (INIS)

    Chen, Zhiye; Li, Lin; Sun, Jie; Ma, Lin

    2012-01-01

    Purpose: To investigate the pattern of brain volume changes of the brain in patients with type II diabetes mellitus using voxel-based morphometry. Material and methods: Institutional ethics approval and informed consent were obtained. VBM based on the high resolution three-dimensional T1-weighted fast spoiled gradient recalled echo MRI images was obtained from 16 type II diabetes patients (mean age 61.2 years) and 16 normal controls (mean age 59.6 years). All images were spatially preprocessed using Diffeomorphic Anatomical Registration using Exponentiated Lie algebra (DARTEL) algorithm, and the DARTEL templates were made from 100 normal subjects. Statistical parametric mapping was generated using analysis of covariance (ANCOVA). Results: An atrophy pattern of gray matter was seen in type II diabetes patients compared with controls that involved the right superior, middle, and inferior temporal gyri, right precentral gyrus, and left rolandic operculum region. The loss of white matter volume in type II diabetes mellitus was observed in right temporal lobe and left inferior frontal triangle region. ROI analysis revealed that the gray and white matter volume of right temporal lobe were significant lower in type II diabetes mellitus than that in controls (P < 0.05). Conclusion: This work demonstrated that type II diabetes mellitus patients mainly exhibited gray and white matter atrophy in right temporal lobe, and this finding supported that type II diabetes mellitus could lead to subtle diabetic brain structural changes in patients without dementia or macrovascular complications.

  5. Mapping the brain in type II diabetes: Voxel-based morphometry using DARTEL

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhiye [Department of Radiology, PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Li, Lin [Department of Geriatric Endocrinology, PLA General Hospital, Beijing 100853 (China); Sun, Jie [Department of Endocrinology, PLA General Hospital, Beijing 100853 (China); Ma, Lin, E-mail: cjr.malin@vip.163.com [Department of Radiology, PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2012-08-15

    Purpose: To investigate the pattern of brain volume changes of the brain in patients with type II diabetes mellitus using voxel-based morphometry. Material and methods: Institutional ethics approval and informed consent were obtained. VBM based on the high resolution three-dimensional T1-weighted fast spoiled gradient recalled echo MRI images was obtained from 16 type II diabetes patients (mean age 61.2 years) and 16 normal controls (mean age 59.6 years). All images were spatially preprocessed using Diffeomorphic Anatomical Registration using Exponentiated Lie algebra (DARTEL) algorithm, and the DARTEL templates were made from 100 normal subjects. Statistical parametric mapping was generated using analysis of covariance (ANCOVA). Results: An atrophy pattern of gray matter was seen in type II diabetes patients compared with controls that involved the right superior, middle, and inferior temporal gyri, right precentral gyrus, and left rolandic operculum region. The loss of white matter volume in type II diabetes mellitus was observed in right temporal lobe and left inferior frontal triangle region. ROI analysis revealed that the gray and white matter volume of right temporal lobe were significant lower in type II diabetes mellitus than that in controls (P < 0.05). Conclusion: This work demonstrated that type II diabetes mellitus patients mainly exhibited gray and white matter atrophy in right temporal lobe, and this finding supported that type II diabetes mellitus could lead to subtle diabetic brain structural changes in patients without dementia or macrovascular complications.

  6. Integrated Monitoring AWAReness Environment (IM-AWARE), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — American GNC Corporation (AGNC) and Louisiana Tech University (LaTECH) are proposing a significant breakthrough technology, the Integrated Monitoring AWAReness...

  7. Eddy current manual, volume 2

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1984-09-01

    This report on eddy current testing is divided into three sections: (a) Demonstration of Basic Principles, (b) Practical (Laboratory) Tests and, (c) Typical Certification Questions. It is intended to be used as a supplement to ΣEddy Current Manual, Volume 1Σ (AECL-7523) during CSNDT Foundation Level II and III courses

  8. INTRA/Mod3.2. Manual and Code Description. Volume I - Physical Modelling

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the Physical modelling of INTRA and the ruling numerical methods and volume II, the User's Manual is an input description. This document, the Physical modelling of INTRA, contains code characteristics, integration methods and applications

  9. INTRA/Mod3.2. Manual and Code Description. Volume I - Physical Modelling

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O; Hermann, J; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the Physical modelling of INTRA and the ruling numerical methods and volume II, the User`s Manual is an input description. This document, the Physical modelling of INTRA, contains code characteristics, integration methods and applications

  10. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume I. Program summary

    International Nuclear Information System (INIS)

    1980-06-01

    This report summarizes the Nonproliferation Alternative Systems Assessment Program (NASAP): its background, its studies, and its results. The introductory chapter traces the growth of the issue of nuclear weapons proliferation and the organization and objectives of NASAP. Chapter 2 summarizes the program's assessments, findings, and recommendations. Each of Volumes II-VII reports on an individual assessment (Volumn II: Proliferation Resistance; Volume III: Resources and Fuel Cycle Facilities; Volume IV: Commercial Potential; Volume V: Economics and Systems Analysis; Volume VI: Safety and Environmental Considerations for Licensing; Volume VII: International Perspectives). Volume VIII (Advanced Concepts) presents a combined assessment of several less fully developed concepts, and Volume IX (Reactor and Fuel Cycle Descriptions) provides detailed descriptions of the reactor and fuel-cycle systems studied by NASAP

  11. Final programmatic environmental impact statement for the uranium mill tailings remedial action ground water project. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-10-01

    Volume II of the programmatic environmental impact statement (PElS) is a comment and response document; it is the collection of the comments received on the draft PElS. The U.S. Department of Energy's (DOE) response to each comment is provided after each comment. If the comment resulted in a change to the PElS, the affected section number of the PElS is provided in the response. Comments 1 through 259 were received at public hearings. The name of the hearing at which the comment was received is listed after each comment. Comments were recorded on flip charts and by notetakers. DOE representatives were present to hear the comments and respond to them. The DOE's written response is provided after each comment. Comments 260 through 576 were received in writing at the hearings, and from various federal, tribal, and state agencies and from individuals during the public comment period. Copies of the written comments follow the comments and responses.

  12. Final programmatic environmental impact statement for the uranium mill tailings remedial action ground water project. Volume II

    International Nuclear Information System (INIS)

    1996-01-01

    Volume II of the programmatic environmental impact statement (PElS) is a comment and response document; it is the collection of the comments received on the draft PElS. The U.S. Department of Energy's (DOE) response to each comment is provided after each comment. If the comment resulted in a change to the PElS, the affected section number of the PElS is provided in the response. Comments 1 through 259 were received at public hearings. The name of the hearing at which the comment was received is listed after each comment. Comments were recorded on flip charts and by notetakers. DOE representatives were present to hear the comments and respond to them. The DOE's written response is provided after each comment. Comments 260 through 576 were received in writing at the hearings, and from various federal, tribal, and state agencies and from individuals during the public comment period. Copies of the written comments follow the comments and responses

  13. Method for monitoring the course of oxidation of iodide ion during radioactive iodination operation

    Energy Technology Data Exchange (ETDEWEB)

    Xuezhong, Luo

    1986-05-01

    A micro-iodine ion selective electrode is developed to follow and monitor the course of oxidation of iodide ion during radioactive iodination operation. The experimental results indicate that this method can quickly respond to the course of oxidation if the reacting liquid is greater than 30 micro liter in volume. Therefore it can be used for accurate controlling the amount of oxidzing reagent used for the reaction, for example, the amount of chloroamine T can be reduced to 1/40 of the amount ordinarily used for the preparation of angiotonin II and insulin. The effect of pH and concentration of phosphate of the reacting liquid to the oxidation reaction of I with chloroamine T is also studied.

  14. Relations between brain volumes, neuropsychological assessment and parental questionnaire in prematurely born children.

    Science.gov (United States)

    Lind, Annika; Haataja, Leena; Rautava, Liisi; Väliaho, Anniina; Lehtonen, Liisa; Lapinleimu, Helena; Parkkola, Riitta; Korkman, Marit

    2010-05-01

    The objective of this study is to assess the relationship between brain volumes at term equivalent age and neuropsychological functions at 5 years of age in very low birth weight (VLBW) children, and to compare the results from a neuropsychological assessment and a parental questionnaire at 5 years of age. The study group included a regional cohort of 97 VLBW children and a control group of 161 children born at term. At term equivalent age, brain magnetic resonance imaging (MRI) was performed on the VLBW children, and analysed for total and regional brain volumes. At 5 years of age, a psychologist assessed the neuropsychological performance with NEPSY II, and parents completed the Five to fifteen (FTF) questionnaire on development and behaviour. The results of the control group were used to give the age-specific reference values. No significant associations were found between the brain volumes and the NEPSY II domains. As for the FTF, significant associations were found between a smaller total brain tissue volume and poorer executive functions, between a smaller cerebellar volume and both poorer executive functions and motor skills, and, surprisingly, between a larger volume of brainstem and poorer language functions. Even after adjustment for total brain tissue volume, the two associations between the cerebellar volume and the FTF domains remained borderline significant (P = 0.05). The NEPSY II domains Executive Functioning, Language and Motor Skills were significantly associated with the corresponding FTF domains. In conclusion, altered brain volumes at term equivalent age appear to affect development still at 5 years of age. The FTF seems to be a good instrument when used in combination with other neuropsychological assessment.

  15. Volume dose of organs at risk in the irradiated volume

    International Nuclear Information System (INIS)

    Hishikawa, Yoshio; Tanaka, Shinichi; Miura, Takashi

    1984-01-01

    Absorbed dose of organs at risk in the 50% irradiated volume needs to be carefully monitored because there is high risk of radiation injury. This paper reports on the histogram of threedimensional volume dose of organs at risk, which is obtained by computer calculation of CT scans. In order to obtain this histogram, CT is first performed in the irradiation field. The dose in each pixel is then examined by the computer as to each slice. After the pixels of all slices in the organ at risk of the irradiated field are classified according to the doses, the number of pixels in the same dose class is counted. The result is expressed in a histogram. The histogram can show the differences of influence to organs at risk given by various radiation treatment techniques. Total volume dose of organs at risk after radiotherapy can also be obtained by integration of each dose of different treatment techniques. (author)

  16. Dynamic Strain and Crack Monitoring Sensor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research proposes to develop a new automated vehicle health monitoring sensor system capable of measuring loads and detecting crack, corrosion, and...

  17. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    Science.gov (United States)

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  18. 1Q/2Q00 M-Area and Metallurgical Laboratory Hazardous Waste Management Facilities Groundwater Monitoring and Corrective-Action Report - First and Second Quarters 2000 - Volumes I, II, and II

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    2000-10-24

    This report describes the groundwater monitoring and corrective-action program at the M-Area Hazardous Waste Management Facility (HWMF) and the Metallurgical Laboratory (Met Lab) HWMF at the Savannah River site (SRS) during first and second quarters of 2000.

  19. 1Q/2Q00 M-Area and Metallurgical Laboratory Hazardous Waste Management Facilities Groundwater Monitoring and Corrective-Action Report - First and Second Quarters 2000 - Volumes I, II, and II

    International Nuclear Information System (INIS)

    Chase, J.

    2000-01-01

    This report describes the groundwater monitoring and corrective-action program at the M-Area Hazardous Waste Management Facility (HWMF) and the Metallurgical Laboratory (Met Lab) HWMF at the Savannah River site (SRS) during first and second quarters of 2000

  20. Selective removal of cesium from aqueous solutions with nickel (II) hexacyanoferrate (III) functionalized agricultural residue–walnut shell

    International Nuclear Information System (INIS)

    Ding, Dahu; Lei, Zhongfang; Yang, Yingnan; Feng, Chuanping; Zhang, Zhenya

    2014-01-01

    Highlights: • Novel biosorbent for cesium removal was derived from agricultural residue. • It could remove cesium effectively from aqueous solution. • Large size of granules makes it easy to be separated from solutions. • The volume of used biosorbent could be significantly reduced after incineration. • Incinerated biosorbent has a low volume and a low cost final disposal. - Abstract: A novel nickel (II) hexacyanoferrate (III) functionalized agricultural residue-walnut shell (Ni II HCF III -WS) was developed to selectively remove cesium ion (Cs + ) from aqueous solutions. This paper showed the first integral study on Cs + removal behavior and waste reduction analysis by using biomass adsorption material. The results indicated that the removal process was rapid and reached saturation within 2 h. As a special characteristic of Ni II HCF III -WS, acidic condition was preferred for Cs + removal, which was useful for extending the application scope of the prepared biomass material in treating acidic radioactive liquid waste. The newly developed Ni II HCF III -WS could selectively remove Cs + though the coexisting ions (Na + and K + in this study) exhibited negative effects. In addition, approximately 99.8% (in volume) of the liquid waste was reduced by using Ni II HCF III -WS and furthermore 91.9% (in volume) of the spent biomass material (Cs-Ni II HCF III -WS) was reduced after incineration (at 500 °C for 2 h). Due to its relatively high distribution coefficient and significant volume reduction, Ni II HCF III -WS is expected to be a promising material for Cs + removal in practice

  1. USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process. Volume 2

    National Research Council Canada - National Science Library

    Adamson, Anthony

    1998-01-01

    .... It is published as three separate volumes. Volume I, USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process -- Phase II Report, discusses the result and cost/benefit analysis of testing three initiatives...

  2. USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process. Volume 1

    National Research Council Canada - National Science Library

    Adamson, Anthony

    1998-01-01

    .... It is published as three separate volumes. Volume I, USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process -- Phase II Report, discusses the result and cost/benefit analysis of testing three initiatives...

  3. High-Performance Contaminant Monitor for Spacecraft, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Vision for Space Exploration demands increasing reliance on real-time trace gas monitors onboard spacecraft. Present grab samples and badges will be inadequate...

  4. 3-color DPAS Aerosol Absorption Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a highly sensitive and compact RGB DPAS aerosol absorption monitor for NASA's Airborne Measurement Program. It will measure aerosol light...

  5. No-migration variance petition. Volume 3, Revision 1: Appendix B, Attachments A through D

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    Volume III contains the following attachments: TRUPACT-II content codes (TRUCON); TRUPACT-II chemical list; chemical compatibility analysis for Rocky Flats Plant waste forms (Appendix 2.10.12 of TRUPACT-II safety analysis report); and chemical compatibility analyses for waste forms across all sites.

  6. Environmental report 1994. Volume No. 2

    International Nuclear Information System (INIS)

    Rath, K.S.; Harrach, R.J.; Gallegos, G.M.; Failor, R.A.; Christofferson, E.

    1995-01-01

    This volume 2 of the Lawrence Livermore National Laboratory's (LLNL's) annual Environmental Report 1994 is a detailed data report that provides individual data points, where applicable, along with some summary data and more detailed accounts of sample collection and analytical methods. Six chapters have information on monitoring of air, surface water, groundwater, soil and sediment, vegetation and foodstuffs, and environmental radiation; two other chapters cover compliance sel-monitoring and quality assurance

  7. Mercury emission monitoring on municipal waste combustion

    International Nuclear Information System (INIS)

    Braun, H.; Gerig, A.

    1991-01-01

    In waste incineration, mercury is the only heavy metal to be released as a gas, mostly as mercury(II) chloride, because of its high volatility. Continuous emission monitoring is possible only when mercury occurs in its elemental form. This paper reports on various possibilities of converting Hg(II) into Hg(0) that has been studied and tested on a laboratory scale and in the TAMARA refuse incineration pilot facility. Continuous mercury emission measurement appears to be possible, provided mercury is converted in the flue gas condensate precipitated. The measuring results obtained on two municipal solid waste and on one sewage treatment sludge incineration plants show that the mercury monitor is a highly sensitive and selective continuously working instrument for mercury emission monitoring

  8. Analysis of the permitting processes associated with exploration of Federal OCS leases. Final report. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    1980-11-01

    Under contract to the Office of Leasing Policy Development (LPDO), Jack Faucett Associates is currently undertaking the description and analysis of the Outer Continental Shelf (OCS) regulatory process to determine the nature of time delays that affect OCS production of oil and gas. This report represents the results of the first phase of research under this contract, the description and analysis of regulatory activity associated with exploration activities on the Federal OCS. Volume 1 contains the following three sections: (1) study results; (2) Federal regulatory activities during exploration of Federal OCS leases which involved the US Geological Survey, Environmental Protection Agency, US Coast Guard, Corps of Engineers, and National Ocean and Atmospheric Administration; and (3) state regulatory activities during exploration of Federal OCS leases of Alaska, California, Louisiana, Massachusetts, New Jersey, North Carolina and Texas. Volume II contains appendices of US Geological Survey, Environmental Protection Agency, Coast Guard, Corps of Engineers, the Coastal Zone Management Act, and Alaska. The major causes of delay in the regulatory process governing exploration was summarized in four broad categories: (1) the long and tedious process associated with the Environmental Protection Agency's implementation of the National Pollutant Discharge Elimination System Permit; (2) thelack of mandated time periods for the completion of individual activities in the permitting process; (3) the lack of overall coordination of OCS exploratory regulation; and (4) the inexperience of states, the Federal government and industry relating to the appropriate level of regulation for first-time lease sale areas.

  9. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study

    International Nuclear Information System (INIS)

    Gargiulo, Gaetano D; Breen, Paul P; O’Loughlin, Aiden

    2015-01-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need. In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial. (note)

  10. Magnetic Field Monitoring in the SNS and LANL Neutron EDM Experiments

    Science.gov (United States)

    Aleksandrova, Alina; SNS nEDM Collaboration; LANL nEDM Collaboration

    2017-09-01

    The SNS neutron EDM experiment requires the ability to precisely control and monitor the magnetic field inside of the fiducial volume. However, it is not always practical (or even possible) to measure the field within the region of interest directly. To remedy this issue, we have designed a field monitoring system that will allow us to reconstruct the field inside of the fiducial volume using noninvasive measurements of the field components at discrete locations external to this volume. A prototype probe array (consisting of 12 single-axis fluxgate magnetometer sensors) was used to monitor the magnetic field within the fiducial volume of an in-house magnetic testing apparatus. In this talk, the design and results of this test will be presented, and the possible implementation of this field monitoring method may have in the room temperature LANL neutron EDM experiment will be discussed. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-SC-0014622.

  11. PATRAM '80. Proceedings. Volume 1

    International Nuclear Information System (INIS)

    Huebner, H.W.

    1980-01-01

    Volume 1 contains papers from the following sessions: Plenary Session; Regulations, Licensing and Standards; LMFBR Systems Concepts; Risk/Safety Assessment I; Systems and Package Design; US Institutional Issues; Risk/Safety Assessment II; Leakage, Leak Rate and Seals; Poster Session A; Operations and Systems Experience I; Manufacturing Processes and Materials; and Quality Assurance and Maintenance. Individual papers were processed. (LM)

  12. Fiscal Year 1986 Department of Energy authorization (basic research programs). Volume II-B. Hearing before the Subcommittee on Energy Development and Applications of the Committee on Science and Technology, US House of Representatives, Ninety-Ninth Congress, First Session, February 28, 1985

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    Volume II-B of the hearing record contains Appendix 3 and Appendix 4 of Volume II-A. Appendix 3 provides supporting materials on the accomplishments and project summaries of the various departments under the Office of Basic Energy Sciences. This includes DOE supported work in engineering, chemistry, biology, mathematics, geology, and the energy sciences. Appendix 4 provides summaries of DOE supported work on high energy physics, which investigates the nature of matter and the behavior of matter and energy. Over 90% of the funding for this work comes from DOE, which is responsible for national planning in the effort to develop accelerator facilities, the superconducting super collider, and other physics programs

  13. Controlled synthesized natroalunite microtubes applied for cadmium(II) and phosphate co–removal

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Huan [School of Physics and Materials Science, Anhui University, Hefei 230601 (China); Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Zhu, Baisheng [University of Science and Technology of China, Hefei 230026 (China); Ren, Xuemei, E-mail: renxm1985@163.com [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Shao, Dadong; Tan, Xiaoli; Chen, Changlun [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China)

    2016-08-15

    Highlights: • Five natroalunite samples with different morphologies were synthesized. • EG: water ratio controls the morphology and adsorption performance of natroalunite. • NMs show the best performance in Cd(II) and phosphate co-uptake. • Phosphate bridges NMs and Cd(II) in co–removal process and enhances Cd(II) uptake. - Abstract: Treatment of wastewater containing several kinds of contaminants poses great challenges, because heavy metal and inorganic anion contaminants possess different fate and transport mechanisms. Individual adsorption of Cd(II)/phosphate on clay or metallic oxides has been extensively investigated, but the mutual effects of these two species in co–existing systems have received little attention. In this study, five natroalunite samples with different morphologies were synthesized by a simple hydrothermal method with appropriate volume ratio of ethylene glycol (EG) to water. The volume ratio of EG to water plays a key role in the formation of natroalunite samples, and dramatically affects their adsorption capacities. The mutual effects of Cd(II) and phosphate on their interaction with natroalunite microtubes (NMs) were investigated by varying experimental conditions, such as pH, temperature and addition sequences. The results demonstrate that highly efficient co–removal of Cd(II) and phosphate can be accomplished using NMs, and the process is strongly dependent on solution pH and temperature via the formation of ternary surface complexes. This study implies that the hydrothermally synthesized NMs can be regarded as a potential promising material for the co–removal of Cd(II) and phosphate from large volumes of aqueous solutions in pollution management.

  14. A theoretical approach to calibrate radiation portal monitor (RPM) systems

    International Nuclear Information System (INIS)

    Nafee, Sherif S.; Abbas, Mahmoud I.

    2008-01-01

    Radiation portal monitor (RPM) systems are widely used at international border crossings, where they are applied to the task of detecting nuclear devices, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, the former being required to rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce [Chambers, W.H., Atwater, H.F., Fehlau, P.E., Hastings, R.D., Henry, C.N., Kunz, W.E., Sampson, T.E., Whittlesey, T.H., Worth, G.M., 1974. Portal Monitor for Diversion Safeguards. LA-5681, Los Alamos Scientific Laboratory, Los Alamos, NM]. In the present work, compact analytical formulae are derived and used to calibrate two RPM systems with isotropic radiating sources: (i) polyvinyltoluene (PVT) or plastic and (ii) thallium-doped crystalline sodium iodide, NaI(Tl), gamma-ray detector materials. The calculated efficiencies are compared to measured values reported in the literatures, showing very good agreement

  15. Monitoring WLCG with lambda-architecture: a new scalable data store and analytics platform for monitoring at petabyte scale.

    CERN Document Server

    Magnoni, L; Cordeiro, C; Georgiou, M; Andreeva, J; Khan, A; Smith, D R

    2015-01-01

    Monitoring the WLCG infrastructure requires the gathering and analysis of a high volume of heterogeneous data (e.g. data transfers, job monitoring, site tests) coming from different services and experiment-specific frameworks to provide a uniform and flexible interface for scientists and sites. The current architecture, where relational database systems are used to store, to process and to serve monitoring data, has limitations in coping with the foreseen increase in the volume (e.g. higher LHC luminosity) and the variety (e.g. new data-transfer protocols and new resource-types, as cloud-computing) of WLCG monitoring events. This paper presents a new scalable data store and analytics platform designed by the Support for Distributed Computing (SDC) group, at the CERN IT department, which uses a variety of technologies each one targeting specific aspects of big-scale distributed data-processing (commonly referred as lambda-architecture approach). Results of data processing on Hadoop for WLCG data activities mon...

  16. Best-practices guidelines for L2PSA development and applications. Volume 2 - Best practices for the Gen II PWR, Gen II BWR L2PSAs. Extension to Gen III reactors

    International Nuclear Information System (INIS)

    Raimond, E.; Durin, T.; Rahni, N.; Meignen, R.; Cranga, M.; Pichereau, F.; Bentaib, A.; Guigueno, Y.; Loeffler, H.; Mildenberger, O.; Lajtha, G.; Santamaria, C.S.; Dienstbier, J.; Rydl, A.; Holmberg, J.E.; Lindholm, I.; Maennistoe, I.; Pauli, E.M.; Dirksen, G.; Grindon, L.; Peers, K.; Hulqvist, G.; Parozzi, F.; Polidoro, F.; Cazzoli, E.; Vitazkova, J.; Burgazzi, L.; Oury, L.; Ngatchou, C.; Siltanen, S.; Niemela, I.; Routamo, T.; Helstroem, P.; Bassi, C.; Brinkman, H.; Seidel, A.; Schubert, B.; Wohlstein, R.; Guentay, S.; Vincon, L.

    2010-01-01

    The objective of this coordinated action was to develop best practice guidelines for the performance of Level 2 PSA methodologies with a view of harmonisation at EU level and to allow meaningful and practical uncertainty evaluations in a Level 2 PSA. Specific relationships with community in charge of nuclear reactor safety (utilities, safety authorities, vendors, and research or services companies) have been established in order to define the current needs in terms of guidelines for level 2 PSA development and applications. An international workshop was organised in Hamburg, with the support of VATTENFALL, in November 2008. The level 2 PSA experts from the ASAMPSA2 project partners have proposed some guidelines for the development and application of L2PSA based on their experience and on information available from international cooperation (EC Severe Accident network of Excellence - SARNET, IAEA standards, OECD-NEA publications and workshop) or open literature. The number of technical issues addressed in the guideline is very large and all are not covered with the same relevancy in the first version of the guideline. This version is submitted for external review in November 2010 by severe accident experts and PSA, especially, from SARNET and OECD-NEA members. The feedback of the external review will be dis cussed during an international open works hop planned in March 2011 and all outcomes will be taken into consideration in the final version of this guideline (June 2011). The guideline includes 3 volumes: - Volume 1 - General considerations on L2PSA. - Volume 2 - Technical recommendations for Gen II and III reactors. - Volume 3 - Specific considerations for future reactor (Gen IV). The recommendations formulated in the guideline should not be considered as 'mandatory' but should help the L2PSA developers to achieve high quality studies with limited time and resources. It may also help the L2PSA reviewers by positioning one specific study in comparison with some

  17. MANAJEMEN KULTUR ROTIFER DENGAN TANGKI VOLUME KECIL

    Directory of Open Access Journals (Sweden)

    Philip Teguh Imanto

    2009-04-01

    Full Text Available Keberhasilan pembenihan ikan sangat dipengaruhi keberhasilan produksi jasad pakan rotifer secara tepat dan efisien. Penelitian kultur rotifer dengan tangki volume kecil bertujuan untuk mendapatkan efisiensi produksi yang paling optimal dan memenuhi prinsip dasar akuakultur low volume high density. Penelitian menggunakan tangki polyethylene dengan volume 500 L dan volume media awal 100 L, padat tebar awal 200 ind. rotifer per mL dengan sediaan pakan dasar fitoplankton Nannocloropsis occulata, ragi roti (0,05 g/mio.rot./feeding dan suplemen Scott emulsion (0,005 g/mio.rot./feeding. Penelitian dilakukan secara bertahap; tahap pertama (I tanpa penambahan air laut, peningkatan volume hanya dari penambahan 15 L Nannochloropsis tiap hari sampai hari kelima, tahap kedua (II dengan penambahan alga 40 L dan air laut 40 L; serta tahap ketiga (III dengan menggandakan pemberian ragi roti. Hasil penelitian menunjukkan bahwa pada percobaan tahap I: total produksi rata-rata 122,37 x 106 ind. rotifer, pada tahap II: 97,67 x 106 ind. rotifer, dan pada tahap III: dicapai rata-rata total produksi tertinggi dengan 187,17 x 106 ind. rotifer per tanki kultur 500 L. Pengelolaan kultur pada tahap III memberikan hasil terbaik dengan simpangan terkecil antar tangki kultur ulangan, dan membuktikan sebagai pengelolaan terbaik untuk kultur rotifer dengan tangki volume kecil.  Success of marine seed production is highly influenced by effective and efficient production performance of life food rotifer. Observation on rotifer culture using small volume tank was aimed to get the optimum production and efficiency, to fulfill the basic principle of aquaculture “low volume high density”. Polyethylene tanks of 500 L. were used as culture container, with initial 100 liter sea water as culture medium and initial density of 200 ind. rotifer per mL. N. occulata, baker yeast (0.05 g/mio.rotifer/feeding and Scott emulsion (0.005 g/mio.rotifer/feeding were used as basic feed, and

  18. Adsorption behavior of multiwall carbon nanotube/iron oxide magnetic composites for Ni(II) and Sr(II)

    International Nuclear Information System (INIS)

    Chen Changlun; Hu Jun; Shao Dadong; Li Jiaxing; Wang Xiangke

    2009-01-01

    Multiwall carbon nanotube (MWCNT)/iron oxide magnetic composites were prepared, and were characterized by scan electron microscopy using a field emission scanning electron microscope, X-ray diffraction and vibrating sample magnetometer. The adsorptions of Ni(II) and Sr(II) onto MWCNT/iron oxide magnetic composites were studied as a function of pH and ionic strength. The results show that the adsorptions of Ni(II) and Sr(II) on the magnetic composites is strongly dependent on pH and ionic strength. The adsorption capacity of the magnetic composites is much higher than that of MWCNTs and iron oxides. The solid magnetic composites can be separated from the solution by a magnetic process. The Langmuir model fits the adsorption isotherm data of Ni(II) better than the Freundlich model. Results of desorption study shows that Ni(II) adsorbed onto the magnetic composites can be easily desorbed at pH < 2.0. MWCNT/iron oxide magnetic composites may be a promising candidate for pre-concentration and solidification of heavy metal ions and radionuclides from large volumes of aqueous solution, as required for remediation purposes.

  19. FIX-II/3025, BWR FIX-II Pump Trip Experiment 3025, Immediate Split Size Break

    International Nuclear Information System (INIS)

    NILSSON, Lars; GUSTAFSSON, Per-Ake; GUSTAFSON, Lennart; JANCZAK, Rajmund; OESTERLUNDH, Ingrid

    1992-01-01

    1 - Description of test facility: The FIX-II facility is a volume scaled 1:777 representation of a Swedish BWR with external pumps. The pressure vessel contains a 36 rod full length bundle and a spray condenser at the top to allow steady state operation. The downcomer, bypass channels and guide tube volumes are represented by external piping. The intact loop represents three of the four external reactor loops. The broken loop is constructed such that both guillotine breaks and split breaks may be simulated. The facility is equipped with ADS-simulation, but no ECCS injection are included. The FIX-II loop is also suited to investigate response of pump trips and MSIV closures in internal pump reactors. 2 - Description of test: Test 3025 simulates an intermediate size split break in one of the four main recirculation lines. The break area was 31 per cent of the scaled down pipe area of the reactor. The initial power of the 36-rod bundle was 3.38 MW, corresponding to the hot channel power of the reactor

  20. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  1. Selective removal of cesium from aqueous solutions with nickel (II) hexacyanoferrate (III) functionalized agricultural residue–walnut shell

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Dahu, E-mail: dingdahu@gmail.com [Graduate School of Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8572 (Japan); Lei, Zhongfang; Yang, Yingnan [Graduate School of Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8572 (Japan); Feng, Chuanping [School of Water Resources and Environment, China University of Geosciences (Beijing), Key Laboratory of Groundwater Circulation and Evolution, Ministry of Education, Beijing 100083 (China); Zhang, Zhenya, E-mail: zhang.zhenya.fu@u.tsukuba.ac.jp [Graduate School of Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8572 (Japan)

    2014-04-01

    Highlights: • Novel biosorbent for cesium removal was derived from agricultural residue. • It could remove cesium effectively from aqueous solution. • Large size of granules makes it easy to be separated from solutions. • The volume of used biosorbent could be significantly reduced after incineration. • Incinerated biosorbent has a low volume and a low cost final disposal. - Abstract: A novel nickel (II) hexacyanoferrate (III) functionalized agricultural residue-walnut shell (Ni{sup II}HCF{sup III}-WS) was developed to selectively remove cesium ion (Cs{sup +}) from aqueous solutions. This paper showed the first integral study on Cs{sup +} removal behavior and waste reduction analysis by using biomass adsorption material. The results indicated that the removal process was rapid and reached saturation within 2 h. As a special characteristic of Ni{sup II}HCF{sup III}-WS, acidic condition was preferred for Cs{sup +} removal, which was useful for extending the application scope of the prepared biomass material in treating acidic radioactive liquid waste. The newly developed Ni{sup II}HCF{sup III}-WS could selectively remove Cs{sup +} though the coexisting ions (Na{sup +} and K{sup +} in this study) exhibited negative effects. In addition, approximately 99.8% (in volume) of the liquid waste was reduced by using Ni{sup II}HCF{sup III}-WS and furthermore 91.9% (in volume) of the spent biomass material (Cs-Ni{sup II}HCF{sup III}-WS) was reduced after incineration (at 500 °C for 2 h). Due to its relatively high distribution coefficient and significant volume reduction, Ni{sup II}HCF{sup III}-WS is expected to be a promising material for Cs{sup +} removal in practice.

  2. Radiation monitoring of Syr-Darya river (II)

    International Nuclear Information System (INIS)

    Yuldashev, B.S.; Salikhbaev, U.S.; Radyuk, R.I.; Vdovina, E.D.; Artemov, S.V.; Radyuk, G.A.; Zaparov, E.A.; Howard, H.D.; Barber, D.S.; Betsill, J.D.; Matthews, R.; Solodukhin, V.P.; Poznyak, V.L.; Vasiliev, I.A.; Alekhina, V.M.; Djuraev, A.A.; Djuraev, An.A.

    2004-01-01

    The article contains the results obtained during the radiation monitoring of Syr-Darya River, which was conducted within the frames of international collaboration of Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan, and USA. The data on the nature of radionuclide distribution of uranium and thorium rows in bottom and soil is presented. Reasons of formation of the observed dependence of the obtained results on the distance from the source are discussed. (author)

  3. Evaluasi Risiko Keterlambatan Pekerjaan Pembangunan Apron Baru Bandara Sultan Syarif Kasim II, Pekanbaru

    OpenAIRE

    Yulita, Syifa; Sandhyavitri, Ari; Malik, Alfian

    2017-01-01

    Implementation of the project of New Apron Development Workshop of Sultan Syarif Kasim II Airport, Pekanbaru from initial observations of previous authors poses a risk during the construction period of unpredictable events by civil engineer is a force majure condition such as unpredictable volume during interim planning The time set does not include unexpected or over volume work. The delay that occurred in the project of Advanced Construction Work of New Apron Sultan Syarif Kasim II Airport,...

  4. 40 CFR 63.1023 - Instrument and sensory monitoring for leaks.

    Science.gov (United States)

    2010-07-01

    ... be used during that day's monitoring. (ii) A calibration gas other than methane in air may be used if... or more of the compounds to be measured in air. (5) Monitoring performance. Monitoring shall be... devices) or § 63.1031(f) (alternative compressor standard). (d) Sensory monitoring methods. Sensory...

  5. White Matter Volume Predicts Language Development in Congenital Heart Disease.

    Science.gov (United States)

    Rollins, Caitlin K; Asaro, Lisa A; Akhondi-Asl, Alireza; Kussman, Barry D; Rivkin, Michael J; Bellinger, David C; Warfield, Simon K; Wypij, David; Newburger, Jane W; Soul, Janet S

    2017-02-01

    To determine whether brain volume is reduced at 1 year of age and whether these volumes are associated with neurodevelopment in biventricular congenital heart disease (CHD) repaired in infancy. Infants with biventricular CHD (n = 48) underwent brain magnetic resonance imaging (MRI) and neurodevelopmental testing with the Bayley Scales of Infant Development-II and the MacArthur-Bates Communicative Development Inventories at 1 year of age. A multitemplate based probabilistic segmentation algorithm was applied to volumetric MRI data. We compared volumes with those of 13 healthy control infants of comparable ages. In the group with CHD, we measured Spearman correlations between neurodevelopmental outcomes and the residuals from linear regression of the volumes on corrected chronological age at MRI and sex. Compared with controls, infants with CHD had reductions of 54 mL in total brain (P = .009), 40 mL in cerebral white matter (P Development-II scores but did correlate positively with MacArthur-Bates Communicative Development Inventory language development. Infants with biventricular CHD show total brain volume reductions at 1 year of age, driven by differences in cerebral white matter. White matter volume correlates with language development, but not broader developmental indices. These findings suggest that abnormalities in white matter development detected months after corrective heart surgery may contribute to language impairment. ClinicalTrials.gov: NCT00006183. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Vitamin E alters alveolar type II cell phospholipid synthesis in oxygen and air

    International Nuclear Information System (INIS)

    Kennedy, K.A.; Snyder, J.M.; Stenzel, W.; Saito, K.; Warshaw, J.B.

    1990-01-01

    Newborn rats were injected with vitamin E or placebo daily until 6 days after birth. The effect of vitamin E pretreatment on in vitro surfactant phospholipid synthesis was examined in isolated type II cells exposed to oxygen or air form 24 h in vitro. Type II cells were also isolated from untreated 6-day-old rats and cultured for 24 h in oxygen or air with control medium or vitamin E supplemented medium. These cells were used to examine the effect of vitamin E exposure in vitro on type II cell phospholipid synthesis and ultrastructure. Phosphatidylcholine (PC) synthesis was reduced in cells cultured in oxygen as compared with air. This decrease was not prevented by in vivo pretreatment or in vitro supplementation with vitamin E. Vitamin E pretreatment increased the ratio of disaturated PC to total PC and increased phosphatidylglycerol synthesis. The volume density of lamellar bodies in type II cells was increased in cells maintained in oxygen. Vitamin E did not affect the volume density of lamellar bodies. We conclude that in vitro hyperoxia inhibits alveolar type II cell phosphatidylcholine synthesis without decreasing lamellar body volume density and that supplemental vitamin E does not prevent hyperoxia-induced decrease in phosphatidylcholine synthesis

  7. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 1: Concepts of Use, Initial System Requirements, Architecture, and AeroMACS Design Considerations

    Science.gov (United States)

    Hall, Edward; Isaacs, James; Henriksen, Steve; Zelkin, Natalie

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I (this document) is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  8. Instrumentation for environmental monitoring. Volume 1. Radiation. Second Edition

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Nero, A.V.; Murphy, D.J.; Graven, R.

    1983-01-01

    This volume describes ionizing radiation and the instruments used for measurement. Units, sources, and effects of radiation are introduced, basic detection methods discussed, and measurement of alpha, beta, gamma and x-radiation described. Sources of anthropogenic radiation are discussed in detail: nuclear power plants, spent-fuel processing, and uranium mining and milling

  9. Coal slurry combustion and technology. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Volume II contains papers presented at the following sessions of the Coal Slurry Combustion and Technology Symposium: (1) bench-scale testing; (2) pilot testing; (3) combustion; and (4) rheology and characterization. Thirty-three papers have been processed for inclusion in the Energy Data Base. (ATT)

  10. Wireless air monitoring network with new AMIZ-2004G dust monitors

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Machaj, B.; Pienkos, P.; Swistowski, E.

    2006-01-01

    The principle of operation of the dust monitors is based on determination of dust mass deposited on air filters from known volumes of air samples. The dust mass is determined from radiation attenuation of a Pm-147 beta source. MIZA and AMIZ monitors produced in the Institute of Nuclear Chemistry and Technology, Warsaw (Poland) additionally measure relative humidity, atmospheric pressure and temperature of the air. In case the measurements are made in a few different places, direct collection of the results requires that personnel of the environment protection units has to go frequently to the monitors and collect the data. To improve the data transmission, a new version of the AMIZ-2004G monitor was developed which is equipped with a GSM modem enabling communication with a central computer. Thanks to the new construction not only a remote wireless communication with AMIZ is possible, but also a monitoring network containing a higher number of dust monitors can be made. The measuring data from all the monitors in the network can now be collected in one central computer equipped with the GSM modem and a proper acquisition program. In 2005, two such monitoring networks were put into operation

  11. INEL environmental characterization report. Volume II. Appendices A-D

    International Nuclear Information System (INIS)

    1984-09-01

    This volume contains appendices: (1) a socioeconomic data base for southeastern Idaho; (2) an ecological characterization of the INEL; (3) site-specific climatology summary, NPR primary and alternate sites; (4) NPR site borehole completion; (5) an investigation of the principal lineament at the INEL; (6) an investigation of Clay Butte, Idaho; (7) Arco and Howe fault study; (8) seismology of the INEL; (9) geologic map of the INEL; and (1) geologic ages of the INEL

  12. Environmental Report 1995. Volume 1

    International Nuclear Information System (INIS)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M.

    1996-09-01

    This report contains the results of Lawrence Livermore National Laboratory's (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL's environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present

  13. Topography of π--irradiated volumes

    International Nuclear Information System (INIS)

    Bueche, G.

    1976-02-01

    The charge exchange reaction π - p → π 0 n and the radiative capture of negative pions π - p → nγ can be used to control the range of π - in matter like human tissue. The calculations reported in this paper demonstrate that it is possible to construct range monitors which allow the radiation therapist immediate control of the π - beam setting with respect to the tumor volume. This monitoring of range can be achieved from outside the body within short times compared to irradiation times which are typical in therapy. (orig.) [de

  14. Environmental Report 1995. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M. [and others

    1996-09-01

    This report contains the results of Lawrence Livermore National Laboratory`s (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL`s environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present.

  15. Photo-Geomorphology of Coastal Landforms, Cat Island, Bahamas. Volume II,

    Science.gov (United States)

    The report provides the aerial imagery used in the analysis of the coastal landforms of Cat Island in the east-central Bahama Islands. Interpretive...published volume Coastal Landform of Cat Island, Bahamas: A Study of Holocene Accretionary Topography and Sea-Level Change but may also serve as an

  16. Encouraging energy conservation in multifamily housing: RUBS and other methods of allocating energy costs to residents

    Energy Technology Data Exchange (ETDEWEB)

    McClelland, L

    1980-10-01

    Methods of encouraging energy conservation in multifamily housing by allocating energy costs to residents are discussed; specifically, methods appropriate for use in master metered buildings without equipment to monitor energy consumption in individual apartments are examined. Several devices available for monitoring individual energy consumption are also discussed plus methods of comparing the energy savings and cost effectiveness of monitoring devices with those of other means of promoting conservation. Specific information in Volume I includes a comparison study on energy use in master and individually metered buildings; types of appropriate conservation programs for master metered buildings; a description of the Resident Utility Billing System (RUBS); energy savings associated with RUBS; Resident reactions to RUBS; cost effectiveness of RUBS for property owners; potential abuses, factors limiting widespread use, and legal status of RUBS. Part I of Volume II contains a cost allocation decision guide and Part II in Volume II presents the RUBS Operations Manual. Pertinent appendices to some chapters are attached. (MCW)

  17. Atlas of Ohio Aquatic Insects: Volume II, Plecoptera.

    Science.gov (United States)

    DeWalt, R Edward; Grubbs, Scott A; Armitage, Brian J; Baumann, Richard W; Clark, Shawn M; Bolton, Michael J

    2016-01-01

    We provide volume II of a distributional atlas of aquatic insects for the eastern USA state of Ohio. This treatment of stoneflies (Plecoptera) is companion to Armitage et al. (2011) on caddisflies (Trichoptera). We build on a recent analysis of Ohio stonefly diversity patterns based on large drainages (DeWalt et al. 2012), but add 3717 new records to the data set. We base most analyses on the United States Geological Survey Hierarchical Unit Code eight (HUC8) drainage scale. In addition to distributional maps for each species, we provide analyses of species richness versus HUC8 drainage area and the number of unique locations in a HUC8 drainage, species richness versus Ohio counties, analyze adult presence phenology throughout the year, and demonstrate stream size range affiliation for each species. This work is based on a total of 7797 specimen records gathered from 21 regional museums, agency data, personal collections, and from the literature Table 1. To our knowledge this is the largest stonefly data set available for a similarly sized geopolitical area anywhere in the world. These data are made available as a Darwin Core Archive supported by the Pensoft Integrated Publishing Toolkit (DeWalt et al. 2016b). All known published papers reporting stoneflies from Ohio are detailed in Suppl. material 1. We recovered 102 species from Ohio, including all nine Nearctic families Table 2​. Two species were removed from the DeWalt et al. (2012) list and two new state records added. Perlidae (32 spp.) was most speciose, compared to the low diversity Pteronarcyidae (2 spp.) and Peltoperlidae (1 sp.). The richest HUC8 drainages occurred in northeastern, south-central, and southern regions of the state where drainages were heavily forested, had the highest slopes, and were contained within or adjacent to the unglaciated Allegheny and Appalachian Plateaus. Species poor drainages occurred mainly in the northwestern region where Wisconsinan aged lake plains climaxed to an

  18. Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II

    International Nuclear Information System (INIS)

    Tsuda, S.; Yoshida, T.; Tsutsumi, M.; Saito, K.

    2015-01-01

    The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. - Highlights: • KURAMA-II is a car-borne survey system developed by Kyoto University. • A spectrum-dose conversion operator for KURAMA-II was calculated and examined. • We examined the radiation characteristics of KURAMA-II such as energy dependence. • KURAMA-II has acceptable quality for environmental mass dose rate monitoring

  19. Central receiver solar thermal power system. Phase 1. CDRL item 2; Pilot Plant preliminary design report. Volume II. System decription and system analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hallet, Jr., R. W.; Gervais, R. L.

    1977-10-01

    An active system analysis and integration effort has been maintained. These activities have included the transformation of initial program requirements into a preliminary system design, the evolution of subsystem requirements which lay the foundation for subsystem design and test activity, and the overseeing of the final preliminary design effort to ensure that the subsystems are operationally compatible and capable of producing electricity at the lowest possible cost per unit of energy. Volume II of the Preliminary Design Report presents the results of the overall system effort that went on during this contract. The effort is assumed to include not only the total system definition and design but also all subsystem interactions.

  20. Contribution and significance of Heidelberg retinal tomography II in diagnostics of ocular hypertension and its conversion into primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Marković Vujica

    2009-01-01

    last one. Conclusion. In diagnosing ocular hypertension and its conversion to glaucoma, HRT II is used for quantitative evaluation of retinal topography and for quantitative monitoring of topographical changes, especially regarding the increase of C/D ratio and loss of rim volume tissue, which enables to see and register subtle structural changes in optic nerve head and RNFL that are so characteristic for glaucoma, which cannot be seen by an ophthalmoscope. With these results, according to risk factors for glaucoma, one can confirm the diagnosis of ocular hypertension and its conversion to primary open-angle glaucoma. In this study HRT II revealed conversion of ocular hypertension into glaucoma in 10% of the patients.

  1. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.

    Science.gov (United States)

    Katz, Philip O; Rex, Douglas K; Epstein, Michael; Grandhi, Nav K; Vanner, Stephen; Hookey, Lawrence C; Alderfer, Vivian; Joseph, Raymond E

    2013-03-01

    Optimal bowel preparation is vital for the efficacy and safety of colonoscopy. The inconvenience, discomfort, required consumption of large volumes of product, and potential adverse effects associated with some bowel preparations deter patients from colonoscopy and may provide inadequate cleansing. A dual-action, non-phosphate, natural orange-flavored, low-volume preparation containing sodium picosulfate and magnesium citrate (P/MC) is currently being reviewed for bowel cleansing. This was a phase 3, randomized, multicenter, assessor-blinded, prespecified non-inferiority, head-to-head study to investigate the efficacy, safety, and tolerability of day-before administration of P/MC vs. 2L polyethylene glycol solution and two 5-mg bisacodyl tablets (2L PEG-3350 and bisacodyl tablets (HalfLytely and Bisacodyl Tablets Bowel Prep Kit)) in adult patients preparing for colonoscopy (SEE CLEAR II Study). The primary objective of the study was to demonstrate the non-inferiority of P/MC to 2L PEG-3350 and bisacodyl tablets in overall colon cleansing using a modified Aronchick scale. In addition, efficacy in the ascending, mid (transverse and descending), and recto-sigmoid segments of colon was evaluated using a modified Ottawa scale. Patient acceptability and tolerability of the bowel preparations were assessed via a standard questionnaire. Safety was assessed based on the monitoring of adverse events (AEs) and meaningful findings on clinical evaluations including physical examinations, vital sign measurements, and electrocardiograms (ECGs). A total of 603 patients were randomized to receive either P/MC (n = 300) or 2L PEG-3350 and bisacodyl tablets (n = 303). Based on the Aronchick scale, successful overall cleansing was similar in patients receiving P/MC (83.0%) and patients receiving 2L PEG-3350 and bisacodyl tablets (79.7%). P/MC demonstrated non-inferiority to 2L PEG-3350 and bisacodyl tablets in overall cleansing of the colon, as measured by the Aronchick scale

  2. The European Dioxin Emission Inventory. Stage II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Quass, U.; Fermann, M.; Broeker, G.

    2001-07-01

    For Stage II of the European Dioxin Project the following objectives were set: - Amendment of existing emission data collected for most relevant emission sources in order to reduce uncertainties of emission estimates. Collecting first emission data from countries not yet performing dioxin emission measurement programs. Extending the inventory of dioxin emissions to ambient air produced in Stage I by a complementary study on emissions to land and water. Extending the regional scope of data collection to countries in Central Europe. The report of Stage II of the European Dioxin Project is presented in 3 Volumes. Volume 1 contains an overview on the background and approach of different activities carried out and on the results obtained. These results are put into a broader view regarding the dioxin reduction measures in Europe leading to conclusions and recommendation for future work. Volume 2 of the report contains a detailed presentation of the sub-projects carried out. The chapters of Volume 2 are structured in a similar manner and start with a short summary in order to allow for a fast cross-reading. In the case of the desk-top studies an overview of the main results or statements is given. Regarding emission measurements details on the experimental set-up and the facilities being investigated are presented. Volume 3 contains a re-evaluation of the dioxin emission inventory presented for the most relevant sources types in the Stage I report. New data gathered from the projects of Stage II as well as from independent activities in the European countries are considered for a revision of the 1995 emission estimates. Additionally, based on current trends and activities the PCDD/F emissions for the years 2000 and 2005 are estimated. Finally, an attempt is made to evaluate the PCDD/F emission reduction rates which might be possible to achieve by the year 2005 compared to 1985. (orig.)

  3. Wide Area Wind Field Monitoring Status & Results

    Energy Technology Data Exchange (ETDEWEB)

    Alan Marchant; Jed Simmons

    2011-09-30

    Volume-scanning elastic has been investigated as a means to derive 3D dynamic wind fields for characterization and monitoring of wind energy sites. An eye-safe volume-scanning lidar system was adapted for volume imaging of aerosol concentrations out to a range of 300m. Reformatting of the lidar data as dynamic volume images was successfully demonstrated. A practical method for deriving 3D wind fields from dynamic volume imagery was identified and demonstrated. However, the natural phenomenology was found to provide insufficient aerosol features for reliable wind sensing. The results of this study may be applicable to wind field measurement using injected aerosol tracers.

  4. Commingled uranium-tailings study. Volume II. Technical report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-06-30

    Public Law 96-540, Section 213, directs the Secretary of Energy to develop a plan for a cooperative program to provide assistance in the stabilization and management of defense-related uranium mill tailings commingled with other tailings. In developing the plan, the Secretary is further directed to: (1) establish the amount and condition of tailings generated under federal contracts; (2) examine appropriate methodologies for establishing the extent of federal assistance; and (3) consult with the owners and operators of each site. This technical report summarizes US Department of Energy (DOE) and contractor activities in pursuit of items (1), (2), and (3) above. Recommendations regarding policy and a cooperative plan for federal assistance are under separate cover as Volume I.

  5. Selective noble gases monitoring

    International Nuclear Information System (INIS)

    Janecka, S.; Jancik, O.; Kapisovsky, V.; Kubik, I.; Sevecka, S.

    1995-01-01

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: 88 Kr(67; 22) Bq/m 3 ; 85m Kr(17; 7) Bq/m 3 ; 135m Xe(7.1; 0.5) Bq/m 3 ; 138 Xe(5.9; 0.9) Bq/m 3 . (J.K.)

  6. Selective noble gases monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Janecka, S; Jancik, O; Kapisovsky, V; Kubik, I; Sevecka, S [Nuclear Power Plants Research Institute, a.s., Trnava (Slovakia)

    1996-12-31

    The monitoring of leak releases from ventilation stack of NPP requires a system by several orders more sensitive then currently used radiometer Kalina, designed to cover the range up to a design-based accident. To reach this goal a noble gases monitor with a germanium detector (MPVG) has been developed. It enables nuclide selective monitoring of current value of volume activity of particular nuclides in ventilation stack and daily releases of noble gases (balancing). MPVG can be viewed as a system build of three levels of subsystem: measuring level; control level; presentation level. Measuring level consists of gamma-spectroscopy system and operational parameters monitoring unit (flow rate, temperature, humidity). Control level provides communication between presentation and measuring level, acquisition of operational parameters and power supply. The presentation level of MPVG enables: 1) the measured data storage in predetermined time intervals; 2) the presentation of measured and evaluated values of radiation characteristics. The monitored radionuclides - default set: argon-41, krypton-85m, krypton-87, krypton-88, krypton-89, xenon-131m, xenon-133, xenon-133m, xenon-135, xenon-135m, xenon-137 and xenon-138. The values of volume activities observed at maximum releases have been approximately ten times higher. In that case in balancing some other nuclides exceed corresponding detection limits: {sup 88}Kr(67; 22) Bq/m{sup 3}; {sup 85m}Kr(17; 7) Bq/m{sup 3}; {sup 135m}Xe(7.1; 0.5) Bq/m{sup 3}; {sup 138}Xe(5.9; 0.9) Bq/m{sup 3}. (J.K.).

  7. Murine Automated Urine Sampler (MAUS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II effort involves the development of a novel rodent spaceflight habitat, focusing on care and monitoring of mice for gravitational physiology...

  8. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 1, Rev. 14

    International Nuclear Information System (INIS)

    1994-10-01

    The condensed version of the TRUPACT-II Contact Handled Transuranic Waste Safety Analysis Report for Packaging (SARP) contains essential material required by TRUPACT-II users, plus additional contents (payload) information previously submitted to the U.S. Nuclear Regulatory Commission. All or part of the following sections, which are not required by users of the TRUPACT-II, are deleted from the condensed version: (i) structural analysis, (ii) thermal analysis, (iii) containment analysis, (iv) criticality analysis, (v) shielding analysis, and (vi) hypothetical accident test results

  9. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 1, Rev. 14

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    The condensed version of the TRUPACT-II Contact Handled Transuranic Waste Safety Analysis Report for Packaging (SARP) contains essential material required by TRUPACT-II users, plus additional contents (payload) information previously submitted to the U.S. Nuclear Regulatory Commission. All or part of the following sections, which are not required by users of the TRUPACT-II, are deleted from the condensed version: (i) structural analysis, (ii) thermal analysis, (iii) containment analysis, (iv) criticality analysis, (v) shielding analysis, and (vi) hypothetical accident test results.

  10. Selective removal of cesium from aqueous solutions with nickel (II) hexacyanoferrate (III) functionalized agricultural residue-walnut shell.

    Science.gov (United States)

    Ding, Dahu; Lei, Zhongfang; Yang, Yingnan; Feng, Chuanping; Zhang, Zhenya

    2014-04-15

    A novel nickel (II) hexacyanoferrate (III) functionalized agricultural residue-walnut shell (Ni(II)HCF(III)-WS) was developed to selectively remove cesium ion (Cs(+)) from aqueous solutions. This paper showed the first integral study on Cs(+) removal behavior and waste reduction analysis by using biomass adsorption material. The results indicated that the removal process was rapid and reached saturation within 2h. As a special characteristic of Ni(II)HCF(III)-WS, acidic condition was preferred for Cs(+) removal, which was useful for extending the application scope of the prepared biomass material in treating acidic radioactive liquid waste. The newly developed Ni(II)HCF(III)-WS could selectively remove Cs(+) though the coexisting ions (Na(+) and K(+) in this study) exhibited negative effects. In addition, approximately 99.8% (in volume) of the liquid waste was reduced by using Ni(II)HCF(III)-WS and furthermore 91.9% (in volume) of the spent biomass material (Cs-Ni(II)HCF(III)-WS) was reduced after incineration (at 500°C for 2h). Due to its relatively high distribution coefficient and significant volume reduction, Ni(II)HCF(III)-WS is expected to be a promising material for Cs(+) removal in practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Management control and status reports documentation standard and Data Item Descriptions (DID). Volume of the information system life-cycle and documentation standards, volume 5

    Science.gov (United States)

    Callender, E. David; Steinbacher, Jody

    1989-01-01

    This is the fifth of five volumes on Information System Life-Cycle and Documentation Standards. This volume provides a well organized, easily used standard for management control and status reports used in monitoring and controlling the management, development, and assurance of informations systems and software, hardware, and operational procedures components, and related processes.

  12. Process monitoring in high volume semiconductor production environment with in-fab TXRF

    International Nuclear Information System (INIS)

    Ghatak-Roy, A.R.; Hossain, T.Z.

    2000-01-01

    After its introduction in the 80's, TXRF has become an important tool for surface contamination analysis. This is particularly true for the semiconductor industries, where monitoring trace level contamination in ultra clean environment is absolutely necessary for successful device production with reasonable yield. In FAB 25 of the Advanced Micro Devices in Austin, we have installed two TXRF tools, which are model TXRF3750 manufactured by Rigaku. They contain rotating tungsten anodes with three beam capability for wide selection of elements. One of the beams (WM) is used for monitoring of low Z elements such as Na, Mg and Al. The standard output is 9 kW with 300 mA at 30 kV. The tool runs 24 hours a day, 7 days a week, except for maintenance and breakdowns. We have been using TXRF for in-fab monitoring of various tools and processes for trace contamination and some quantification of materials. This in-fab operation is important because it gives real time monitoring without the necessity of bringing the wafers out of the fab. Secondly, being in ultra clean fab environment, the risk of background contamination is minimized. Since TXRF measurement is fast and does not need any sample preparation, this works very well as production support tool. Several wafer fab technicians have been trained to use the tool for round the clock operation. We have successfully monitored tools and processes in our fab. One example is the monitoring of numerous sinks used in the cleaning of production wafers after various processes. Monitor wafers are run after sink cleaning and solvent changes and they are then analyzed for any contamination. Another example is the monitoring of tools that use Ferrofluidic seals so as to prevent any contamination from Fe and Cr. Other tools using TXRF include diffusion furnaces, etchers and plasma cleaning tools. We have also been monitoring processes such as ion implantation, metal deposition and rapid thermal annealing. In this presentation, we will

  13. Modification of cell volume and proliferative capacity of Pseudokirchneriella subcapitata cells exposed to metal stress

    International Nuclear Information System (INIS)

    Machado, Manuela D.; Soares, Eduardo V.

    2014-01-01

    Highlights: •Metals induce morphological alterations on P. subcapitata. •Algal cell cycle consists: mother cell growth; cell division, with two nucleus divisions; release of four autospores. •Cu(II) and Cr(VI) arrest cell growth before the first nuclear division. •Cd(II) arrests cell growth after the second nuclear division but before the cytokinesis. •The approach used can be useful in the elucidation of different modes of action of pollutants. -- Abstract: The impact of metals (Cd, Cr, Cu and Zn) on growth, cell volume and cell division of the freshwater alga Pseudokirchneriella subcapitata exposed over a period of 72 h was investigated. The algal cells were exposed to three nominal concentrations of each metal: low (closed to 72 h-EC 10 values), intermediate (closed to 72 h-EC 50 values) and high (upper than 72 h-EC 90 values). The exposure to low metal concentrations resulted in a decrease of cell volume. On the contrary, for the highest metal concentrations an increase of cell volume was observed; this effect was particularly notorious for Cd and less pronounced for Zn. Two behaviours were found when algal cells were exposed to intermediate concentrations of metals: Cu(II) and Cr(VI) induced a reduction of cell volume, while Cd(II) and Zn(II) provoked an opposite effect. The simultaneous nucleus staining and cell image analysis, allowed distinguishing three phases in P. subcapitata cell cycle: growth of mother cell; cell division, which includes two divisions of the nucleus; and, release of four autospores. The exposure of P. subcapitata cells to the highest metal concentrations resulted in the arrest of cell growth before the first nucleus division [for Cr(VI) and Cu(II)] or after the second nucleus division but before the cytokinesis (release of autospores) when exposed to Cd(II). The different impact of metals on algal cell volume and cell-cycle progression, suggests that different toxicity mechanisms underlie the action of different metals

  14. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  15. Vibration-based monitoring and diagnostics using compressive sensing

    Science.gov (United States)

    Ganesan, Vaahini; Das, Tuhin; Rahnavard, Nazanin; Kauffman, Jeffrey L.

    2017-04-01

    Vibration data from mechanical systems carry important information that is useful for characterization and diagnosis. Standard approaches rely on continually streaming data at a fixed sampling frequency. For applications involving continuous monitoring, such as Structural Health Monitoring (SHM), such approaches result in high volume data and rely on sensors being powered for prolonged durations. Furthermore, for spatial resolution, structures are instrumented with a large array of sensors. This paper shows that both volume of data and number of sensors can be reduced significantly by applying Compressive Sensing (CS) in vibration monitoring applications. The reduction is achieved by using random sampling and capitalizing on the sparsity of vibration signals in the frequency domain. Preliminary experimental results validating CS-based frequency recovery are also provided. By exploiting the sparsity of mode shapes, CS can also enable efficient spatial reconstruction using fewer spatially distributed sensors. CS can thereby reduce the cost and power requirement of sensing as well as streamline data storage and processing in monitoring applications. In well-instrumented structures, CS can enable continued monitoring in case of sensor or computational failures.

  16. Infarct volume predicts critical care needs in stroke patients treated with intravenous thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Faigle, Roland; Marsh, Elisabeth B.; Llinas, Rafael H.; Urrutia, Victor C. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States); Wozniak, Amy W. [Johns Hopkins University, Department of Biostatistics, Bloomberg School of Public Health, Baltimore, MD (United States)

    2014-10-26

    Patients receiving intravenous thrombolysis with recombinant tissue plasminogen activator (IVT) for ischemic stroke are monitored in an intensive care unit (ICU) or a comparable unit capable of ICU interventions due to the high frequency of standardized neurological exams and vital sign checks. The present study evaluates quantitative infarct volume on early post-IVT MRI as a predictor of critical care needs and aims to identify patients who may not require resource intense monitoring. We identified 46 patients who underwent MRI within 6 h of IVT. Infarct volume was measured using semiautomated software. Logistic regression and receiver operating characteristics (ROC) analysis were used to determine factors associated with ICU needs. Infarct volume was an independent predictor of ICU need after adjusting for age, sex, race, systolic blood pressure, NIH Stroke Scale (NIHSS), and coronary artery disease (odds ratio 1.031 per cm{sup 3} increase in volume, 95 % confidence interval [CI] 1.004-1.058, p = 0.024). The ROC curve with infarct volume alone achieved an area under the curve (AUC) of 0.766 (95 % CI 0.605-0.927), while the AUC was 0.906 (95 % CI 0.814-0.998) after adjusting for race, systolic blood pressure, and NIHSS. Maximum Youden index calculations identified an optimal infarct volume cut point of 6.8 cm{sup 3} (sensitivity 75.0 %, specificity 76.7 %). Infarct volume greater than 3 cm{sup 3} predicted need for critical care interventions with 81.3 % sensitivity and 66.7 % specificity. Infarct volume may predict needs for ICU monitoring and interventions in stroke patients treated with IVT. (orig.)

  17. Infarct volume predicts critical care needs in stroke patients treated with intravenous thrombolysis

    International Nuclear Information System (INIS)

    Faigle, Roland; Marsh, Elisabeth B.; Llinas, Rafael H.; Urrutia, Victor C.; Wozniak, Amy W.

    2015-01-01

    Patients receiving intravenous thrombolysis with recombinant tissue plasminogen activator (IVT) for ischemic stroke are monitored in an intensive care unit (ICU) or a comparable unit capable of ICU interventions due to the high frequency of standardized neurological exams and vital sign checks. The present study evaluates quantitative infarct volume on early post-IVT MRI as a predictor of critical care needs and aims to identify patients who may not require resource intense monitoring. We identified 46 patients who underwent MRI within 6 h of IVT. Infarct volume was measured using semiautomated software. Logistic regression and receiver operating characteristics (ROC) analysis were used to determine factors associated with ICU needs. Infarct volume was an independent predictor of ICU need after adjusting for age, sex, race, systolic blood pressure, NIH Stroke Scale (NIHSS), and coronary artery disease (odds ratio 1.031 per cm 3 increase in volume, 95 % confidence interval [CI] 1.004-1.058, p = 0.024). The ROC curve with infarct volume alone achieved an area under the curve (AUC) of 0.766 (95 % CI 0.605-0.927), while the AUC was 0.906 (95 % CI 0.814-0.998) after adjusting for race, systolic blood pressure, and NIHSS. Maximum Youden index calculations identified an optimal infarct volume cut point of 6.8 cm 3 (sensitivity 75.0 %, specificity 76.7 %). Infarct volume greater than 3 cm 3 predicted need for critical care interventions with 81.3 % sensitivity and 66.7 % specificity. Infarct volume may predict needs for ICU monitoring and interventions in stroke patients treated with IVT. (orig.)

  18. How long do the dead survive on the road? Carcass persistence probability and implications for road-kill monitoring surveys.

    Directory of Open Access Journals (Sweden)

    Sara M Santos

    Full Text Available BACKGROUND: Road mortality is probably the best-known and visible impact of roads upon wildlife. Although several factors influence road-kill counts, carcass persistence time is considered the most important determinant underlying underestimates of road mortality. The present study aims to describe and model carcass persistence variability on the road for different taxonomic groups under different environmental conditions throughout the year; and also to assess the effect of sampling frequency on the relative variation in road-kill estimates registered within a survey. METHODOLOGY/PRINCIPAL FINDINGS: Daily surveys of road-killed vertebrates were conducted over one year along four road sections with different traffic volumes. Survival analysis was then used to i describe carcass persistence timings for overall and for specific animal groups; ii assess optimal sampling designs according to research objectives; and iii model the influence of road, animal and weather factors on carcass persistence probabilities. Most animal carcasses persisted on the road for the first day only, with some groups disappearing at very high rates. The advisable periodicity of road monitoring that minimizes bias in road mortality estimates is daily monitoring for bats (in the morning and lizards (in the afternoon, daily monitoring for toads, small birds, small mammals, snakes, salamanders, and lagomorphs; 1 day-interval (alternate days for large birds, birds of prey, hedgehogs, and freshwater turtles; and 2 day-interval for carnivores. Multiple factors influenced the persistence probabilities of vertebrate carcasses on the road. Overall, the persistence was much lower for small animals, on roads with lower traffic volumes, for carcasses located on road lanes, and during humid conditions and high temperatures during the wet season and dry seasons, respectively. CONCLUSION/SIGNIFICANCE: The guidance given here on monitoring frequencies is particularly relevant to provide

  19. How long do the dead survive on the road? Carcass persistence probability and implications for road-kill monitoring surveys.

    Science.gov (United States)

    Santos, Sara M; Carvalho, Filipe; Mira, António

    2011-01-01

    Road mortality is probably the best-known and visible impact of roads upon wildlife. Although several factors influence road-kill counts, carcass persistence time is considered the most important determinant underlying underestimates of road mortality. The present study aims to describe and model carcass persistence variability on the road for different taxonomic groups under different environmental conditions throughout the year; and also to assess the effect of sampling frequency on the relative variation in road-kill estimates registered within a survey. Daily surveys of road-killed vertebrates were conducted over one year along four road sections with different traffic volumes. Survival analysis was then used to i) describe carcass persistence timings for overall and for specific animal groups; ii) assess optimal sampling designs according to research objectives; and iii) model the influence of road, animal and weather factors on carcass persistence probabilities. Most animal carcasses persisted on the road for the first day only, with some groups disappearing at very high rates. The advisable periodicity of road monitoring that minimizes bias in road mortality estimates is daily monitoring for bats (in the morning) and lizards (in the afternoon), daily monitoring for toads, small birds, small mammals, snakes, salamanders, and lagomorphs; 1 day-interval (alternate days) for large birds, birds of prey, hedgehogs, and freshwater turtles; and 2 day-interval for carnivores. Multiple factors influenced the persistence probabilities of vertebrate carcasses on the road. Overall, the persistence was much lower for small animals, on roads with lower traffic volumes, for carcasses located on road lanes, and during humid conditions and high temperatures during the wet season and dry seasons, respectively. The guidance given here on monitoring frequencies is particularly relevant to provide conservation and transportation agencies with accurate numbers of road

  20. Removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution using rice husk-based activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Mohd F., E-mail: faisalt@petronas.com.my; Shaharun, Maizatul S. [Fundamental and Applied Sciences Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia); Shuib, Anis Suhaila, E-mail: anisuha@petronas.com.my; Borhan, Azry [Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia)

    2014-10-24

    An attempt was made to investigate the potential of rice husk-based activated carbon as an alternative low-cost adsorbent for the removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Rice husk-based activated carbon was prepared via treatment of rice husk with NaOH followed by the carbonization process at 400°C for 2 hours. Three samples, i.e. raw rice husk, rice husk treated with NaOH and rice husk-based activated carbon, were analyzed for their morphological characteristics using field-emission scanning electron microscope/energy dispersive X-ray (FESEM/EDX). These samples were also analyzed for their carbon, hydrogen, nitrogen, oxygen and silica contents using CHN elemental analyzer and FESEM/EDX. The porous properties of rice husk-based activated carbon were determined by Brunauer-Emmett-Teller (BET) surface area analyzer, and its surface area and pore volume were 255 m{sup 2}/g and 0.17 cm{sup 2}/g, respectively. The adsorption studies for the removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution were carried out at a fixed initial concentration of metal ion (150 ppm) with variation amount of adsorbent (rice husk-based activated carbon) as a function of varied contact time at room temperature. The concentration of each metal ion was analyzed using atomic absorption spectrophotometer (AAS). The results obtained from adsorption studies indicate the potential of rice husk as an economically promising precursor for the preparation of activated carbon for removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Isotherm and kinetic model analyses suggested that the experimental data of adsorption studies fitted well with Langmuir, Freundlich and second-order kinetic models.

  1. Mathematics for natural scientists II advanced methods

    CERN Document Server

    Kantorovich, Lev

    2016-01-01

    This book covers the advanced mathematical techniques useful for physics and engineering students, presented in a form accessible to physics students, avoiding precise mathematical jargon and laborious proofs. Instead, all proofs are given in a simplified form that is clear and convincing for a physicist. Examples, where appropriate, are given from physics contexts. Both solved and unsolved problems are provided in each chapter. Mathematics for Natural Scientists II: Advanced Methods is the second of two volumes. It follows the first volume on Fundamentals and Basics.

  2. Confinement studies in the TJ-II stellarator

    International Nuclear Information System (INIS)

    Alejaldre, C.; Alonso, J.; Almoguera, L.; Ascasibar, E.; Baciero, A.; Balbin, R.; Blaumoser, M.; Botija, J.; Branas, B.; Cal, E. de la; Cappa, A.; Carrasco, R.; Castejon, F.; Cepero, J.R.; Cremy, C.; Delgado, J.M.; Doncel, J.; Dulya, C.; Estrada, T.; Fernandez, A.; Fuentes, C.; Garcia, A.; Garcia-Cortes, I.; Guasp, J.; Herranz, J.; Hidalgo, C.; Jimenez, J.A.; Kirpitchev, I.; Krivenski, V.; Labrador, I.; Lapayese, F.; Likin, K.; Linier, M.; Lopez-Fraguas, A.; Lopez-Sanchez, A.; Luna, E. de la; Martin, R.; Martinez, A.; Martinez-Laso, L.; Medrano, M.; Mendez, P.; McCarthy, K.J.; Medina, F.; Milligen, B. van; Ochando, M.; Pacios, L.; Pastor, I.; Pedrosa, M.A.; Pena, A. de la; Portas, A.; Qin, J.; Rodriguez-Rodrigo, L.; Salas, A.; Sanchez, E.; Sanchez, J.; Tabares, F.; Tafalla, D.; Tribaldos, V.; Vega, J.; Zurro, B.; Akulina, D.; Fedyanin, O.I.; Grebenshchikov, S.; Kharchev, N.; Meshcheryakov, A.; Sarksian, K.A.; Barth, R.; Dijk, G. van; Meiden, H. van der

    1999-01-01

    ECR (electron cyclotron resonance) heated plasmas have been studied in the low magnetic shear TJ-II stellarator (R = 1.5 m, a ECRH = 300 kW, power density = 1-25 W cm -3 ). Recent experiments have explored the flexibility of the TJ-II across a wide range of plasma volumes with different rotational transforms and rational surface densities. In this paper, the main results of this campaign are presented and, in particular, the influence of iota and rational surfaces on plasma profiles is discussed. (author)

  3. RTNS-II utilization

    International Nuclear Information System (INIS)

    Doran, D.G.; Panayotou, N.F.; Powell, R.W.

    1979-12-01

    The objective of the several RTNS-II irradation programs is to maximize information gained from the small test volume available in this unique irradiation facility for application in the fusion materials program. While this facility provides the highest 14 MeV neutron flux available, the flux is generally too low and the irradiation volume too small for testing of engineering materials. Emphasis, therefore, is on identifying damage mechanisms of high energy neutrons and correlating them quantitatively with effects produced by fission neutrons. The information gained will be used to evaluate and calibrate damage and correlation models under development. The scope of the program includes in-situ experiments, postirradiation experiments, irradiation temperatures ranging from 4 0 K to 1,000 0 K, and fluences ranging from 3 x 10 16 to about 3 x 10 19 n/cm 2

  4. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    Science.gov (United States)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  5. Electrokinetic pumping and detection of low-volume flows in nanochannels

    NARCIS (Netherlands)

    Mela, P.; Tas, Niels Roelof; Berenschot, Johan W.; van Nieuwkasteele, Jan William; van den Berg, Albert

    2004-01-01

    Electrokinetic pumping of low-volume rates was performed on-chip in channels of small cross sectional area and height in the sub-m range. The flow was detected with the current monitoring technique by monitoring the change in resistance of the fluid in the channel upon the electroosmosis-driven

  6. Novel Real-Time Flight Envelope Monitoring System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an aircraft flight envelope monitoring system that will provide real-time in-cockpit estimations of aircraft flight envelope boundaries....

  7. Distributed Rocket Engine Testing Health Monitoring System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  8. Inductively coupled plasma emission spectroscopy. Part II: applications and fundamentals. Volume 2

    International Nuclear Information System (INIS)

    Boumans, P.W.J.M.

    1987-01-01

    This is the second part of the two-volume treatise by this well-known and respected author. This volume reviews applications of inductively coupled plasma atomic emission spectroscopy (ICP-AES), summarizes fundamental studies, and compares ICP-AES methods with other methods of analysis. The first six chapters are devoted to specific fields of application, including the following: metals and other industrial materials, geology, the environment, agriculture and food, biology and clinical analysis, and organic materials. The chapter on the analysis of organic materials also covers the special instrumental considerations required when organic solvents are introduced into an inductively coupled plasma. A chapter on the direct analysis of solids completes the first part of this volume. Each of the applications chapters begins with a summary of the types of samples that are encountered in that field, and the kinds of problems that an elemental analysis can help to solve. This is followed by a tutorial approach covering applicability, advantages, and limitations of the methods. The coverage is thorough, including sample handling, storage, and preparation, acid, and fusion dissolution, avoiding contamination, methods of preconcentration, the types of interferences that can be expected and ways to reduce them, and the types of ICP plasmas that are used. The second half of the volume covers fundamental studies of ICP-AES: basic processes of aerosol generation, plasma modeling and computer simulation, spectroscopic diagnostics, excitation mechanisms, and discharge characteristics. This section introduces the experimental and modeling methods that have been used to obtain fundamental information about ICPs

  9. Ocean Thermal Energy Conservation (OTEC) power system development (PDS) II. Preliminary design report

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-10

    This report documents the results and conclusions of the PDS II, Phase I, preliminary design of a 10 MWe OTEC power system, using enhanced plate type heat exchangers, and of representative 0.2 MWe test articles. It further provides the documentation (specifications, drawings, trade studies, etc.) resulting from the design activities. The data and discussions of the technical concepts are organized to respond to the PDS II, Phase II proposal evaluation criteria. This volume, which specifically addresses the three evaluation categories (heat exchangers, rotating machinery, and power system configuration and performance) is an integral part of the Phase II plans (proposal) which describe the technical approach to delivering test articles to OTEC-1. In addition, there is a section which addresses power system cost and net energy analysis and another which discusses the results of stainless steel feasibility studies. Supporting documentation is contained in two appendix volumes.

  10. Improved Combustion Products Monitor for the ISS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Compound Specific Analyzer – Combustion Products, used on the International Space Station as a warning monitor of smoldering or combustion events, is being...

  11. The theoretical and computational models of the GASFLOW-II code

    International Nuclear Information System (INIS)

    Travis, J.R.

    1999-01-01

    GASFLOW-II is a finite-volume computer code that solves the time-dependent compressible Navier-Stokes equations for multiple gas species in a dispersed liquid water two-phase medium. The fluid-dynamics algorithm is coupled to the chemical kinetics of combusting gases to simulate diffusion or propagating flames in complex geometries of nuclear containments. GASFLOW-II is therefore able to predict gaseous distributions and thermal and pressure loads on containment structures and safety related equipment in the event combustion occurs. Current developments of GASFLOW-II are focused on hydrogen distribution, mitigation measures including carbon dioxide inerting, and possible combustion events in nuclear reactor containments. Fluid turbulence is calculated to enhance the transport and mixing of gases in rooms and volumes that may be connected by a ventilation system. Condensation, vaporization, and heat transfer to walls, floors, ceilings, internal structures, and within the fluid are calculated to model the appropriate mass and energy sinks. (author)

  12. TRU Waste Sampling Program: Volume I. Waste characterization

    International Nuclear Information System (INIS)

    Clements, T.L. Jr.; Kudera, D.E.

    1985-09-01

    Volume I of the TRU Waste Sampling Program report presents the waste characterization information obtained from sampling and characterizing various aged transuranic waste retrieved from storage at the Idaho National Engineering Laboratory and the Los Alamos National Laboratory. The data contained in this report include the results of gas sampling and gas generation, radiographic examinations, waste visual examination results, and waste compliance with the Waste Isolation Pilot Plant-Waste Acceptance Criteria (WIPP-WAC). A separate report, Volume II, contains data from the gas generation studies

  13. Magnetite Dissolution Performance of HYBRID-II Decontamination Process

    International Nuclear Information System (INIS)

    Kim, Seonbyeong; Lee, Woosung; Won, Huijun; Moon, Jeikwon; Choi, Wangkyu

    2014-01-01

    In this study, we conducted the magnetite dissolution performance test of HYBRID-II (Hydrazine Based Reductive metal Ion Decontamination with sulfuric acid) as a part of decontamination process development. Decontamination performance of HYBRID process was successfully tested with the results of the acceptable decontamination factor (DF) in the previous study. While following-up studies such as the decomposition of the post-decontamination HYBRID solution and corrosion compatibility on the substrate metals of the target reactor coolant system have been continued, we also seek for an alternate version of HYBRID process suitable especially for decommissioning. Inspired by the relationship between the radius of reacting ion and the reactivity, we replaced the nitrate ion in HYBRID with bigger sulfate ion to accommodate the dissolution reaction and named HYBRID-II process. As a preliminary step for the decontamination performance, we tested the magnetite dissolution performance of developing HYBRID-II process and compared the results with those of HYBRID process. HYBRID process developed previously is known have the acceptable decontamination performance, but the relatively larger volume of secondary waste induced by anion exchange resin to treat nitrate ion is the one of the problems related in the development of HYBRID process to be applicable. Therefore we alternatively devised HYBRID-II process using sulfuric acid and tested its dissolution of magnetite in numerous conditions. From the results shown in this study, we can conclude that HYBRID-II process improves the decontamination performance and potentially reduces the volume of secondary waste. Rigorous tests with metal oxide coupons obtained from reactor coolant system will be followed to prove the robustness of HYBRID-II process in the future

  14. Boiling water reactor turbine trip (TT) benchmark. Volume II: Summary Results of Exercise 1

    International Nuclear Information System (INIS)

    Akdeniz, Bedirhan; Ivanov, Kostadin N.; Olson, Andy M.

    2005-06-01

    The OECD Nuclear Energy Agency (NEA) completed under US Nuclear Regulatory Commission (NRC) sponsorship a PWR main steam line break (MSLB) benchmark against coupled system three-dimensional (3-D) neutron kinetics and thermal-hydraulic codes. Another OECD/NRC coupled-code benchmark was recently completed for a BWR turbine trip (TT) transient and is the object of the present report. Turbine trip transients in a BWR are pressurisation events in which the coupling between core space-dependent neutronic phenomena and system dynamics plays an important role. The data made available from actual experiments carried out at the Peach Bottom 2 plant make the present benchmark particularly valuable. While defining and coordinating the BWR TT benchmark, a systematic approach and level methodology not only allowed for a consistent and comprehensive validation process, but also contributed to the study of key parameters of pressurisation transients. The benchmark consists of three separate exercises, two initial states and five transient scenarios. The BWR TT Benchmark will be published in four volumes as NEA reports. CD-ROMs will also be prepared and will include the four reports and the transient boundary conditions, decay heat values as a function of time, cross-section libraries and supplementary tables and graphs not published in the paper version. BWR TT Benchmark - Volume I: Final Specifications was issued in 2001 [NEA/NSC/DOC(2001)]. The benchmark team [Pennsylvania State University (PSU) in co-operation with Exelon Nuclear and the NEA] has been responsible for coordinating benchmark activities, answering participant questions and assisting them in developing their models, as well as analysing submitted solutions and providing reports summarising the results for each phase. The benchmark team has also been involved in the technical aspects of the benchmark, including sensitivity studies for the different exercises. Volume II summarises the results for Exercise 1 of the

  15. Volume 2. Probabilistic analysis of HTGR application studies. Supporting data

    International Nuclear Information System (INIS)

    1980-09-01

    Volume II, Probabilistic Analysis of HTGR Application Studies - Supporting Data, gives the detail data, both deterministic and probabilistic, employed in the calculation presented in Volume I. The HTGR plants and the fossil plants considered in the study are listed. GCRA provided the technical experts from which the data were obtained by MAC personnel. The names of the technical experts (interviewee) and the analysts (interviewer) are given for the probabilistic data

  16. Active Sites Environmental Monitoring Program: Mid-FY 1991 report

    Energy Technology Data Exchange (ETDEWEB)

    Ashwood, T.L.; Wickliff, D.S.; Morrissey, C.M.

    1991-10-01

    This report summarizes the activities of the Active Sites Environmental Monitoring Program (ASEMP) from October 1990 through March 1991. The ASEMP was established in 1989 by Solid Waste Operations and the Environmental Sciences Division to provide early detection and performance monitoring at active low-level radioactive waste (LLW) disposal sites in Solid Waste Storage Area (SWSA) 6 and transuranic (TRU) waste storage sites in SWSA 5 as required by chapters II and III of US Department of Energy Order 5820.2A. Monitoring results continue to demonstrate the no LLW is being leached from the storage vaults on the tumulus pads. Loading of vaults on Tumulus II began during this reporting period and 115 vaults had been loaded by the end of March 1991.

  17. Annual report on radioactive discharges and monitoring of the environment 1993. V. 2: Certificates of authorisation and environmental monitoring programmes

    International Nuclear Information System (INIS)

    1994-01-01

    British Nuclear Fuels plc's Certificates of Authorisation, under which it operates, are reproduced in the second volume of the 1993 Annual Report on Radioactive Discharges and Monitoring of the Environment. The report also includes environmental monitoring programmes relating to discharge authorisation for each of the Sellafield, Drigg, Chapelcross, Springfields and Capenhurst sites. (UK)

  18. Study on air pollution monitoring in Korea using low volume air sampler by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong Sam Chung; Jong Hwa Moon, Young Ju Chung; Seung Yeon Cho; Sang Hun Kang

    1999-01-01

    The aim of this research was to enhance the use of nuclear analytical techniques for air pollution studies and to study the feasibility of the use of instrumental neutron activation analysis (INAA) as a routine monitoring tool to reveal environmental pollution sources. For the collection of air particulate samples, the Gent stacked filter unit, low volume sampler with Nucleopore membrane filters were used. Trace elements in samples collected at two suburban residential sites, Taejon and Wonju city in the Republic of Korea, were analyzed by INAA. Variations of the elemental concentrations were measured monthly and the enrichment factors were calculated for the fine (< 2 μm EAD) and coarse size (2-10 μm EAD) fractions. The analytical data were treated statistically to estimate the relationship between the two variables, the concentrations of elements and the total suspended particulate matter. The results were used to describe the emission source and their correlation. (author)

  19. Comparison of the performance of different modified graphene oxide nanosheets for the extraction of Pb(II) and Cd(II) from natural samples

    International Nuclear Information System (INIS)

    Sayar, Omid; Mehrani, Kheirollah; Mehrani, Azadeh; Hoseinzadeh, Fatemeh; Sadeghi, Omid

    2014-01-01

    Graphene nanosheets were modified with amino groups and the resulting material was used as a sorbent for the extraction of cadmium and lead ions. The nanosheets were characterized by IR spectroscopy, transmission electron microscopy, thermal gravimetric analysis and elemental analysis. The effects of sample pH, eluent parameters (type, concentration and volume of eluent), flow rates (of both sample and eluent), and of a variety of other ions on the efficiency of the extraction of Cd(II) and Pb(II) were optimized. Following solid phase extraction, the elements were determined by FAAS. The limits of detection are <0.9 μg L −1 for Pb(II) and <5 ng L −1 for Cd(II). The relative standard deviations are <2.2 %. The method was validated by analyzing several certified reference materials and was then used for Pb(II) and Cd(II) determination in natural waters and vegetables. (author)

  20. Wearable Beat to Beat Blood Pressure Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during space missions. The wearable beat-to-beat blood pressure...

  1. Graphics gems II

    CERN Document Server

    Arvo, James

    1991-01-01

    Graphics Gems II is a collection of articles shared by a diverse group of people that reflect ideas and approaches in graphics programming which can benefit other computer graphics programmers.This volume presents techniques for doing well-known graphics operations faster or easier. The book contains chapters devoted to topics on two-dimensional and three-dimensional geometry and algorithms, image processing, frame buffer techniques, and ray tracing techniques. The radiosity approach, matrix techniques, and numerical and programming techniques are likewise discussed.Graphics artists and comput

  2. Technology transfer package on seismic base isolation - Volume III

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-14

    This Technology Transfer Package provides some detailed information for the U.S. Department of Energy (DOE) and its contractors about seismic base isolation. Intended users of this three-volume package are DOE Design and Safety Engineers as well as DOE Facility Managers who are responsible for reducing the effects of natural phenomena hazards (NPH), specifically earthquakes, on their facilities. The package was developed as part of DOE's efforts to study and implement techniques for protecting lives and property from the effects of natural phenomena and to support the International Decade for Natural Disaster Reduction. Volume III contains supporting materials not included in Volumes I and II.

  3. NURE aerial gamma-ray and magnetic reconnaissance survey of portions of New Mexico, Arizona and Texas. Volume II. New Mexico-Carlsbad NI 31-11 Quadrangle. Final report

    International Nuclear Information System (INIS)

    1981-09-01

    As part of the Department of Energy (DOE) Nation Uranium Resource Evaluation Program, a rotary-wing high sensitivity radiometric and magnetic survey was flown covering the Carlsbad Quadrangle of the State of New Mexico. The area surveyed consisted of approximately 1732 line miles. The survey was flown with a Sikorsky S58T helicopter equipped with a high sensitivity gamma ray spectrometer which was calibrated at the DOE calibration facilities at Walker Field in Grand Junction, Colorado, and the Dynamic Test Range at Lake Mead, Arizona. Instrumentation and data reduction methods are presented in Volume I of this report. The reduced data is presented in the form of stacked profiles, standard deviation anomaly plots, histogram plots and microfiche listings. The results of the geologic interpretation of the radiometric data together with the profiles, anomaly maps and histograms are presented in this Volume II final report

  4. Continuous monitoring systems for indoor radon measurement: construction and results of their testing

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.; Bujnova, A.; Polaskova, A.; Hola, O.

    2007-01-01

    Two continuous radon monitoring systems were built on the basis of the scintillation chambers. The first system used the large volume scintillation chamber with the volume of 4.5 liters and the second one the commercial scintillation chamber with the volume of 1 liter as the detectors for radon concentration measurement. Both systems were calibrated by Ward-Borak method. The detection limits of monitoring systems are 2.9 Bq · m -3 and 5.1 Bq · m -3 respectively, at -2 hour counting period and 30 % statistical uncertainty. The radon monitoring systems and the professional radon monitor AlphaGUARD were tested in real conditions of working room. The testing showed that long-tenn courses of radon activity concentrations obtained by all three monitors are highly correlated (R 2 ∼0.95). Also the average values of radon activity concentrations calculated on the basis of measured data are identical in the scope of counting errors already at the measurement of the radon activity concentrations in the range of (10-120) Bq · m -3 . (authors)

  5. Clinical efficacy of terlipressin in treatment of type II hepatorenal syndrome

    Directory of Open Access Journals (Sweden)

    DING Xiaohong

    2015-05-01

    Full Text Available ObjectiveTo investigate the clinical efficacy of domestic terlipressin in the treatment of type II hepatorenal syndrome (HRS-II. MethodsA total of 25 HRS-II patients admitted to our hospital from November 2011 to June 2014 were recruited into the treatment group, and 28 HRS-II patients treated with dopamine before 2011 were recruited into the control group. Patients in the treatment group were randomly divided into two subgroups: one subgroup (n=12 was given terlipressin once every 8 h, and the other subgroup (n=13 was given terlipressin once every 12 h. Both groups received albumin (Alb infusion to expand the blood volume before treatment with terlipressin or dopamine, and the course of treatment was 7 days. The improvement in clinical symptoms, levels of blood urea nitrogen (BUN, serum creatinine and electrolytes, urine volume, changes in liver function, and ascites disappearance in the two groups before and after treatment were compared. Comparison of categorical data between the two groups was made by χ2 test, and comparison of continuous data was made by t test. ResultsPatients in the control group showed no obvious symptom relief, but those in the treatment group had varying degrees of improvement in clinical symptoms. Neither group had significant changes in liver function and serum sodium level after treatment. The treatment group had significantly more patients whose ascites volume had decreased from large to medium than the control group (χ2=5.705, P<0.05. There was a slight but not significant decrease in the levels of BUN and serum creatinine in the control group after treatment with dopamine (all P>0.05, whereas the urine volume showed significant difference after the treatment (t=15.534, P<0.01. The treatment group showed significant differences in the levels of BUN and serum creatinine and urine volume after terlipressin treatment (t=11.535, 9.941, and 19.685, respectively; all P<0.01, and significant differences in

  6. 40 CFR 63.1303 - Monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ...) Pump revolutions; or (ii) Flow rate. (3) The device used to monitor the parameter from paragraph (b)(2... the National Institute of Standards and Technology Handbook 44 at least once per year by a registered...

  7. ASTEROSEISMOLOGY OF THE NEARBY SN-II PROGENITOR: RIGEL. I. THE MOST HIGH-PRECISION PHOTOMETRY AND RADIAL VELOCITY MONITORING

    International Nuclear Information System (INIS)

    Moravveji, Ehsan; Guinan, Edward F.; Shultz, Matt; Williamson, Michael H.; Moya, Andres

    2012-01-01

    Rigel (β Ori, B8 Ia) is a nearby blue supergiant displaying α Cyg type variability, and is one of the nearest Type II supernova progenitors. As such it is an excellent test bed to study the internal structure of pre-core-collapse stars. In this study, for the first time, we present 28 days of high-precision MOST photometry and over six years of spectroscopic monitoring. We report 19 significant pulsation modes of signal-to-noise ratio, S/N ∼> 4.6 from radial velocities, with variability timescales ranging from 1.21 to 74.7 days, which are associated with high-order low-degree gravity modes. While the radial velocity variations show a degree of correlation with the flux changes, there is no clear interplay between the equivalent widths of different metallic and Hα lines.

  8. ASTEROSEISMOLOGY OF THE NEARBY SN-II PROGENITOR: RIGEL. I. THE MOST HIGH-PRECISION PHOTOMETRY AND RADIAL VELOCITY MONITORING

    Energy Technology Data Exchange (ETDEWEB)

    Moravveji, Ehsan [Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731 (Iran, Islamic Republic of); Guinan, Edward F. [Department of Astronomy, Villanova University, 800 Lancaster Avenue, Villanova, PA 19085 (United States); Shultz, Matt [Royal Military College of Canada, PO Box 17000, Station Forces, Kingston, ON K7K 4B4 (Canada); Williamson, Michael H. [Center of Excellence in Information Systems, Tennessee State University, Nashville, TN (United States); Moya, Andres, E-mail: moravveji@iasbs.ac.ir [Departamento de Astrofisica, Centro de Astrobiologia (INTA-CSIC), PO BOX 78, 28691 Villanueva de la Canada, Madrid (Spain)

    2012-03-10

    Rigel ({beta} Ori, B8 Ia) is a nearby blue supergiant displaying {alpha} Cyg type variability, and is one of the nearest Type II supernova progenitors. As such it is an excellent test bed to study the internal structure of pre-core-collapse stars. In this study, for the first time, we present 28 days of high-precision MOST photometry and over six years of spectroscopic monitoring. We report 19 significant pulsation modes of signal-to-noise ratio, S/N {approx}> 4.6 from radial velocities, with variability timescales ranging from 1.21 to 74.7 days, which are associated with high-order low-degree gravity modes. While the radial velocity variations show a degree of correlation with the flux changes, there is no clear interplay between the equivalent widths of different metallic and H{alpha} lines.

  9. Temperature, salinity, radioisotopes, sediments, and other data from Phase II Outer Continental Shelf (OCS) Monitoring Program in the Santa Maria Basin, California from 21 Oct 1986 to 08 Mar 1987 (NODC Accession 8900198)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are part of the data collected for the California Phase II OCS Monitoring Program of the Santa Maria Basin by Dr. Hyland from Battelle Ocean Science and...

  10. Pressurized helium II-cooled magnet test facility

    International Nuclear Information System (INIS)

    Warren, R.P.; Lambertson, G.R.; Gilbert, W.S.; Meuser, R.B.; Caspi, S.; Schafer, R.V.

    1980-06-01

    A facility for testing superconducting magnets in a pressurized bath of helium II has been constructed and operated. The cryostat accepts magnets up to 0.32 m diameter and 1.32 m length with current to 3000 A. In initial tests, the volume of helium II surrounding the superconducting magnet was 90 liters. Minimum temperature reached was 1.7 K at which point the pumping system was throttled to maintain steady temperature. Helium II reservoir temperatures were easily controlled as long as the temperature upstream of the JT valve remained above T lambda; at lower temperatures control became difficult. Positive control of the temperature difference between the liquid and cold sink by means of an internal heat source appears necessary to avoid this problem. The epoxy-sealed vessel closures, with which we have had considerable experience with normal helium vacuum, also worked well in the helium II/vacuum environment

  11. Load monitoring program: Status and results report. Volume 1: Summary

    International Nuclear Information System (INIS)

    1994-06-01

    British Columbia Hydro conducts a monitoring program to provide information on customer needs and values for planning; to measure customer response, energy savings impacts, and load shape impacts due to changes in rate level, rate restructuring, and Power Smart programs; to estimate end-use consumption and load shapes by customer class; and to provide load information for distribution and system load studies. To achieve these objectives, the monitoring program tracks the characteristics and energy use patterns of a sample of BC Hydro residential, commercial, and industrial customers over a period of several years. The entire sample will be surveyed periodically to obtain information on changes in building characteristics, equipment stocks, and energy-use behavior and attitudes. A report is provided on the status of monitoring program activities and some results obtained in 1993/94. For the residential sector, the results include typical load profiles, end-user demographics, and extent of electric space heating and water heating. In the commercial sector, customers were divided into two main groups. The large-building group was relatively well organized in terms of energy needs and participated in Power Smart programs. The small-building group was relatively energy-inefficient and relatively unaware of Power Smart programs. 43 figs., 15 tabs

  12. No-migration variance petition. Appendices C--J: Volume 5, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1990-03-01

    Volume V contains the appendices for: closure and post-closure plans; RCRA ground water monitoring waver; Waste Isolation Division Quality Program Manual; water quality sampling plan; WIPP Environmental Procedures Manual; sample handling and laboratory procedures; data analysis; and Annual Site Environmental Monitoring Report for the Waste Isolation Pilot Plant.

  13. Solid phase extraction of Cd(II) and Pb(II) using a magnetic metal-organic framework, and their determination by FAAS

    International Nuclear Information System (INIS)

    Sohrabi, Mahmoud Reza; Matbouie, Zahra; Asgharinezhad, Ali Akbar; Dehghani, Ali

    2013-01-01

    We describe a novel magnetic metal-organic framework (MOF) for the preconcentration of Cd(II) and Pb(II) ions. The MOF was prepared from the Fe 3 O 4 -pyridine conjugate and the copper(II) complex of trimesic acid. The MOF was characterized by IR spectroscopy, elemental analysis, SEM and XRD. A Box-Behnken design through response surface methodology and experimental design was used to identify the optimal parameters for preconcentration. Extraction time, amount of magnetic MOF and pH value were found to be critical factors for uptake, while type, volume, concentration of eluent, and elution time are critical in the elution step. The ions were then determined by FAAS. The limits of detection are 0.2 and 1.1 μg L −1 for Cd(II), and Pb(II) ions, respectively, relative standard deviations are −1 of Cd(II) and Pb(II) ions), and the enrichment capacity of the MOF is at around 190 mg g −1 for both ions which is higher than the conventional Fe 3 O 4 -pyridine material. The magnetic MOF was successfully applied to the rapid extraction of trace quantities of Cd(II) and Pb(II) ions in fish, sediment, and water samples. (author)

  14. Portable and fixed monitoring units for tank calibrations and monitoring of process liquids

    International Nuclear Information System (INIS)

    Landat, D.A.; Hunt, B.A.

    1999-01-01

    The development work stems from safeguards support activities carried out at the JRC Ispra, Italy to the inspectorate agencies. A range of measurement equipment covering the needs of the inspector have been designed, developed and tested in both the laboratory and in nuclear facilities. The instruments comprise four units: (1) a portable pressure measurement device, (2) a volume long term monitoring device, (3) an unattended volume measurement system and (4) a level measurement unit. Utilization of the equipment has proven to give independent measurement checks and confirmation of operator's instrumentation and declarations, ensuring continuity of knowledge. (J.P.N.)

  15. First plasmas in the TJ-II flexible Heliac

    International Nuclear Information System (INIS)

    Alejaldre, C.; Alonso, J.; Almoguera, L.; Ascasibar, E.; Baciero, A.; Balbin, R.; Blaumoser, M.; Botija, J.; Branas, B.; Cal, E. de la; Cappa, A.; Carrasco, R.; Castejon, F.; Cepero, J.R.; Cremy, C.; Doncel, J.; Dulya, C.; Estrada, T.; Fernandez, A.; Frances, M.; Fuentes, C.; Garcia, A.; Garcia-Cortes, I.; Guasp, J.; Herranz, J.; Hidalgo, C.; Jimenez, J.A.; Kirpitchev, I.; Krivenski, V.; Labrador, I.; Lapayese, F.; Likin, K.; Liniers, M.; Lopez-Fraguas, A.; Lopez-Sanchez, A.; Luna, E. de la; Martin, R.; Martinez, A.; Medrano, M.; Mendez, P.; McCarthy, K.; Medina, F.; Milligen, B. van; Ochando, M.; Pacios, L.; Pastor, I.; Pedrosa, M.A.; Pena, A. de la; Portas, A.; Qin, J.; Rodriguez-Rodrigo, L.; Salas, A.; Sanchez, E.; Sanchez, J.; Tabares, F.; Tafalla, D.; Tribaldos, V.; Vega, J.; Zurro, B.; Akulina, D.; Fedyanin, O.I.; Grebenshchicov, S.; Kharchev, N.; Meshcheryakov, A.; Barth, R.; Dijk, G. van; Meiden, H. van der; Petrov, S.

    1999-01-01

    The first experimental campaign of the TJ-II stellarator has been conducted using electron cyclotron resonance heating (f=53.2 GHz, P ECRH approx. 250 kW) with a pulse length of Δt approx. (80-200) ms. The flexibility of the device has been used to study five different configurations varying plasma volume and rotational transform. In this paper, the main results of this campaign are presented and, in particular, the influence of plasma-wall interaction phenomena on TJ-II confinement is briefly discussed. (author)

  16. SPECTRAL OPTICAL MONITORING OF THE NARROW-LINE SEYFERT 1 GALAXY Ark 564

    International Nuclear Information System (INIS)

    Shapovalova, A. I.; Burenkov, A. N.; Popović, L. Č.; Kovačević, J.; Chavushyan, V. H.; Valdes, J. R.; Torrealba, J.; Carrasco, L.; Ilić, D.; Kovačević, A.; Kollatschny, W.; Bochkarev, N. G.; León-Tavares, J.; Mercado, A.; Benítez, E.; Dultzin, D.; De la Fuente, E.

    2012-01-01

    We present the results of a long-term (1999-2010) spectral optical monitoring campaign of the active galactic nucleus (AGN) Ark 564, which shows a strong Fe II line emission in the optical. This AGN is a narrow-line Seyfert 1 (NLS1) galaxy, a group of AGNs with specific spectral characteristics. We analyze the light curves of the permitted Hα, Hβ, optical Fe II line fluxes, and the continuum flux in order to search for a time lag between them. Additionally, in order to estimate the contribution of iron lines from different multiplets, we fit the Hβ and Fe II lines with a sum of Gaussian components. We find that during the monitoring period the spectral variation (F max /F min ) of Ark 564 is between 1.5 for Hα and 1.8 for the Fe II lines. The correlation between the Fe II and Hβ flux variations is of higher significance than that of Hα and Hβ (whose correlation is almost absent). The permitted-line profiles are Lorentzian-like and do not change shape during the monitoring period. We investigate, in detail, the optical Fe II emission and find different degrees of correlation between the Fe II emission arising from different spectral multiplets and the continuum flux. The relatively weak and different degrees of correlations between permitted lines and continuum fluxes indicate a rather complex source of ionization of the broad-line emission region.

  17. SPECTRAL OPTICAL MONITORING OF THE NARROW-LINE SEYFERT 1 GALAXY Ark 564

    Energy Technology Data Exchange (ETDEWEB)

    Shapovalova, A. I.; Burenkov, A. N. [Special Astrophysical Observatory of the Russian AS, Nizhnij Arkhyz, Karachaevo-Cherkesia 369167 (Russian Federation); Popovic, L. C.; Kovacevic, J. [Astronomical Observatory, Volgina 7, 11160 Belgrade 74 (Serbia); Chavushyan, V. H.; Valdes, J. R.; Torrealba, J.; Carrasco, L. [Instituto Nacional de Astrofisica, Optica y Electronica, Apartado Postal 51-216, 72000 Puebla (Mexico); Ilic, D.; Kovacevic, A. [Isaac Newton Institute of Chile, Yugoslavia Branch, Belgrade (Serbia); Kollatschny, W. [Institut fuer Astrophysik, Georg-August-Universitaet, Goettingen (Germany); Bochkarev, N. G. [Sternberg Astronomical Institute, Moscow (Russian Federation); Leon-Tavares, J. [Aalto University Metsaehovi Radio Observatory, Metsaehovintie 114, FIN-02540 Kylmaelae (Finland); Mercado, A. [Universidad Politecnica de Baja California, Av. de la Industria 291, 21010 Mexicali, B.C. (Mexico); Benitez, E.; Dultzin, D. [Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, Apartado Postal 70-264, Mexico, D.F. 04510 (Mexico); De la Fuente, E., E-mail: ashap@sao.ru [Instituto de Astronomia y Meteorologia, Dpto. de Fisica CUCEI, Universidad de Guadalajara, Av. Vallarta 2602, 44130 Guadalajara, Jalisco (Mexico)

    2012-09-15

    We present the results of a long-term (1999-2010) spectral optical monitoring campaign of the active galactic nucleus (AGN) Ark 564, which shows a strong Fe II line emission in the optical. This AGN is a narrow-line Seyfert 1 (NLS1) galaxy, a group of AGNs with specific spectral characteristics. We analyze the light curves of the permitted H{alpha}, H{beta}, optical Fe II line fluxes, and the continuum flux in order to search for a time lag between them. Additionally, in order to estimate the contribution of iron lines from different multiplets, we fit the H{beta} and Fe II lines with a sum of Gaussian components. We find that during the monitoring period the spectral variation (F{sub max}/F{sub min}) of Ark 564 is between 1.5 for H{alpha} and 1.8 for the Fe II lines. The correlation between the Fe II and H{beta} flux variations is of higher significance than that of H{alpha} and H{beta} (whose correlation is almost absent). The permitted-line profiles are Lorentzian-like and do not change shape during the monitoring period. We investigate, in detail, the optical Fe II emission and find different degrees of correlation between the Fe II emission arising from different spectral multiplets and the continuum flux. The relatively weak and different degrees of correlations between permitted lines and continuum fluxes indicate a rather complex source of ionization of the broad-line emission region.

  18. Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

    International Nuclear Information System (INIS)

    Yoon, Phil S.; Siddons, D. Peter

    2010-01-01

    We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

  19. Application of Carrier Element-Free Co-precipitation Method for Ni(II), Cu(II) and Zn(II) Ions Determination in Water Samples Using Chrysin

    International Nuclear Information System (INIS)

    Layth Imad Abd Ali; Wan Aini Wan Ibrahim; Azli Sulaiman; Mohd Marsin Sanagi

    2015-01-01

    A co-precipitation method was developed to separate and pre-concentrate Ni(II), Cu(II) and Zn(II) ions using an organic co precipitant, chrysin without adding any carrier element termed as carrier element-free co-precipitation (CEFC). Analytes were determined using flame atomic absorption spectrometry (FAAS). The influence of analytical conditions, such as pH of the solution, quantity of co-precipitant, standing time, centrifugation rate and time, sample volume, and interference of concomitant ions were investigated over the recovery yields of the trace metals. The limit of detection, the limit of quantification and linearity range obtained from the FAAS measurements were found to be in the range of 0.64 to 0.86 μg L -1 , 2.13 to 2.86 μg L -1 and 0.9972 to 0.9989 for Ni(II), Cu(III) and Zn(II) ions, respectively. The precision of the method, evaluated as the relative standard deviation (RSD) obtained after analyzing a series of 10 replicates, was between 2.6 % to 3.9 % for the trace metal ions. The proposed procedure was applied and validated by analyzing river water reference material for trace metals (SLRS-5) and spiking trace metal ions in some water samples. The recoveries of the analyte metal ions were between 94.7-101.2 %. (author)

  20. Key technologies and risk management of deep tunnel construction at Jinping II hydropower station

    Directory of Open Access Journals (Sweden)

    Chunsheng Zhang

    2016-08-01

    Full Text Available The four diversion tunnels at Jinping II hydropower station represent the deepest underground project yet conducted in China, with an overburden depth of 1500–2000 m and a maximum depth of 2525 m. The tunnel structure was subjected to a maximum external water pressure of 10.22 MPa and the maximum single-point groundwater inflow of 7.3 m3/s. The success of the project construction was related to numerous challenging issues such as the stability of the rock mass surrounding the deep tunnels, strong rockburst prevention and control, and the treatment of high-pressure, large-volume groundwater infiltration. During the construction period, a series of new technologies was developed for the purpose of risk control in the deep tunnel project. Nondestructive sampling and in-situ measurement technologies were employed to fully characterize the formation and development of excavation damaged zones (EDZs, and to evaluate the mechanical behaviors of deep rocks. The time effect of marble fracture propagation, the brittle–ductile–plastic transition of marble, and the temporal development of rock mass fracture and damage induced by high geostress were characterized. The safe construction of deep tunnels was achieved under a high risk of strong rockburst using active measures, a support system comprised of lining, grouting, and external water pressure reduction techniques that addressed the coupled effect of high geostress, high external water pressure, and a comprehensive early-warning system. A complete set of technologies for the treatment of high-pressure and large-volume groundwater infiltration was developed. Monitoring results indicated that the Jinping II hydropower station has been generally stable since it was put into operation in 2014.

  1. Thermodynamic study of (heptane + amine) mixtures. II. Excess and partial molar volumes at 298.15 K

    International Nuclear Information System (INIS)

    Lepori, Luciano; Gianni, Paolo; Spanedda, Andrea; Matteoli, Enrico

    2011-01-01

    Research highlights: → Excess and partial molar volumes of primary (amines + heptane) mixtures. → Excess volumes are positive for small size amines and decrease as the size increases. → Group contributions to predict the partial molar volumes of amines in heptane. → The void volume is larger for branched than for linear amines in heptane. - Abstract: Excess molar volumes V E at 298.15 K were determined by means of a vibrating tube densimeter for binary mixtures of heptane + primary n-alkyl (C 3 to C 10 ) and branched amines (iso-propyl-, iso-, sec-, and tert-butyl-, iso-, tert-pentyl-, and pentan-3-amine) in the whole composition range. The apparent molar volumes of solid dodecyl- and tetradecylamine in heptane dilute solution were also determined. The V E values were found positive for mixtures involving C 3 to C 8 linear amines, with V E decreasing with chain lengthening. Heptane + nonyl and decylamine showed s-shaped, markedly asymmetric, curves. Mixtures with branched C 3 to C 5 amines displayed positive V E 's larger than those observed in the mixtures of the corresponding linear isomers. Partial molar volumes V o at infinite dilution in heptane were evaluated for the examined amines and compared with those of alkanes and alkanols taken from the literature. An additivity scheme, based on the intrinsic volume approach, was applied to estimate group (CH 3 , CH 2 , CH, C, NH 2 , and OH) contributions to V o . The effect of branching on V o and the limiting slope of the apparent excess molar volumes were evaluated and discussed in terms of solute-solvent and solute-solute interactions.

  2. Viability Assessment Volume 2

    International Nuclear Information System (INIS)

    1998-01-01

    This volume describes the major design features of the Monitored Geologic Repository. This document is not intended to provide an exhaustive, detailed description of the repository design. Rather, this document summarizes the major systems and primary elements of the design that are radiologically significant, and references the specific technical documents and design analyses wherein the details can be found. Not all portions of the design are at the same level of completeness. Highest priority has been given to assigning resources to advance the design of the Monitored Geologic Repository features that are important to radiological safety and/or waste isolation and for which there is no NRC licensing precedent. Those features that are important to radiological safety and/or waste isolation, but for which there is an NRC precedent, receive second priority. Systems and features that have no impact on radiological safety or waste isolation receive the lowest priority. This prioritization process, referred to as binning, is discussed in more detail in Section 2.3. Not every subject discussed in this volume is given equal treatment with regard to the level of detail provided. For example, less detail is provided for the surface facility design than for the subsurface and waste package designs. This different level of detail is intentional. Greater detail is provided for those functions, structures, systems, and components that play key roles with regard to protecting radiological health and safety and that are not common to existing nuclear facilities already licensed by NRC. A number of radiological subjects are not addressed in the VA, (e.g., environmental qualification of equipment). Environmental qualification of equipment and other radiological safety considerations will be addressed in the LA. Non-radiological safety considerations such as silica dust control and other occupational safety considerations are considered equally important but are not addressed in

  3. Interobserver and Intraobserver Reproducibility with Volume Dynamic Contrast Enhanced Computed Tomography (DCE-CT) in Gastroesophageal Junction Cancer

    DEFF Research Database (Denmark)

    Lundsgaard Hansen, Martin; Fallentin, Eva; Axelsen, Thomas

    2016-01-01

    -dimensional (2D) fixed ROIs) placed in the tumor periphery, (II) 2-dimensional regions of interest (2D-ROI) along the tumor border in the tumor center, and (III) 3-dimensional volumes of interest (3D-VOI) containing the entire tumor volume. Arterial flow, blood volume and permeability (k(trans)) were recorded...

  4. Monitoring and Reporting HACs - A Federalist Approach

    Data.gov (United States)

    U.S. Department of Health & Human Services — Findings from a study entitled, Monitoring and Reporting Hospital-Acquired Conditions - A Federalist Approach, published in Volume 4, Issue 4 of Medicare and...

  5. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  6. Fuel rod puncturing and fission gas monitoring system examination techniques

    International Nuclear Information System (INIS)

    Song, Woong Sup

    1999-02-01

    Fission gas products accumulated in irradiated fuel rod is 1-2 cm 3 in CANDU and 40-50 cm 3 in PWR fuel rod. Fuel rod puncturing and fission gas monitoring system can be used for both CANDU and PWR fuel rod. This system comprises puncturing device located at in cell part and monitoring device located at out cell part. The system has computerized 9 modes and can calculate both void volume and mass volume only single puncturing. This report describes techniques and procedure for operating fuel rod puncturing and gas monitoring system which can be play an important role in successful operation of the devices. Results obtained from the analysis can give more influence over design for fuel rods. (Author). 6 refs., 9 figs

  7. Environmental monitoring for krypton-85

    International Nuclear Information System (INIS)

    Barber, D.E.

    1973-01-01

    85 Kr presents unique environmental monitoring problems because it does not react with other elements and compounds at normal ambient temperatures and pressures. However, elaborate means are available to manage the 85 Kr problem, but a simpler, inexpensive approach is required if monitoring is to be accomplished at many sampling locations. This work shows that environmental monitoring for 85 Kr is possible by collecting air samples in thin plastic bags, and counting the bags for beta particle activity. The direct counting of contained samples of this type makes it possible to detect concentrations less than the public MPC for 85 Kr. The bagged-sample technique is readily adaptable to any environmental monitoring station with power to run a low-volume air pump. The idea of counting the bagged-sample directly is a new, low-cost, approach to environmental gas monitoring which may have application in environmental, clinical, and industrial situations

  8. Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

    Directory of Open Access Journals (Sweden)

    Romain Coulon

    2017-10-01

    Full Text Available The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl, CdZnTe, and LaBr3:Ce. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

  9. Radiation monitoring of Syr-Darya river (II)

    International Nuclear Information System (INIS)

    Salikhbaev, U.S.; Yuldashev, B.S.; Radyuk, R.I.; Vdovina, E.D.; Artemov, S.V.; Radyuk, G.A.; Zaparov, E.A.; Barber, D.S.; Betsill, J.D.; Howard, H.D.; Matthews, R.; Solodukhin, V.P.; Poznyak, V.L.; Vasiliev, I.A.; Alekhina, V.M.; Juraev, A.A.; Juraev, An.A.

    2004-01-01

    Full text: The article contains the results obtained during the radiation monitoring of Syr-Darya River, which was conducted within the frames of international collaboration of Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan, and USA. The data on the radionuclides of water, bottom, water plants and soil was obtained. Dependence of the obtained results on distance form the source is discussed. The results of investigations of radio-ecological situation in river Syr-Darya have been presented. Total 15 control points have been chosen in each of the 4 countries of Central Asia. Sampling of soil, bottom sediment, water and vegetation was made during expeditions. Radionuclide of all environmental objects have been studied. The quantity of the radionuclides Ra-226, K-40, Th-232, and U-238 in all samples was investigated. The amount of radionuclides changes for K-40: from 90 to 920 Bq/kg; Ra-226: from 30 to 150 Bq/kg; Th-232 from 7 to 70 Bq/kg; and U-238: from 5 to 180 Bq/kg. Uranium mines influence the process of formation of natural radioactivity in these rivers. Note that the amount of natural radionuclides uranium and thorium, decay products is highest in stations near uranium mines. We had an opportunity to get only few samples from each site, that's why we had to analyze just average seasonal values. A few samples determined great average deviations. These circumstances did not allow us to determine seasonal changes of characteristics of the investigated samples and trace technological and industrial activities by radionuclides. We saw results of general character and suggested formation models of these changes. However, these results, in our opinion, are interesting and give a general idea about radiation background along Syr-Darya and Narin Rivers. Detailed changes of background (because of seasons and technological changes) can be obtained with systematic and longer monitoring

  10. Savannah River Plant - Project 8980 engineering and design history. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    1957-01-01

    This volume provides an engineering and design history of the 100 area of the Savannah River Plant. This site consisted of five separate production reactor sites, 100-R, P, L, K, and C. The document summarizes work on design of the reactors, support facilities, buildings, siting, etc. for these areas.

  11. SEL/Project Language. Level II, Kindergarten, Volume I (Lessons 1-16).

    Science.gov (United States)

    Valladares, Ann E.; And Others

    The document is an intervention curriculum guide designed to facilitate the initial adjustment of disadvantaged Southeastern children to kindergarten or first grade. The major emphasis is on the teaching of language skills in combination with subject matter learning using a language-experience approach. This volume contains Lessons 1-16 of a…

  12. Site Environmental Report for 2007 Volume I

    International Nuclear Information System (INIS)

    Lackner, Regina E.; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea

    2008-01-01

    The Site Environmental Report is an integrated report on Berkeley Lab's environmental programs to satisfy the requirements of DOE Order 231.1A, Environment, Safety, and Health Reporting. It summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2007. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory's environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities

  13. Final waste management programmatic environmental impact statement for managing treatment, storage, and disposl of radioactive and hazardous waste. Volume II

    International Nuclear Information System (INIS)

    1997-01-01

    The Final Waste Management Programmatic Environmental Impact Statement (WM PEIS) examines the potential environmental and cost impacts of strategic management alternatives for managing five types of radioactive and hazardous wastes that have resulted and will continue to result from nuclear defense and research activities at a variety of sites around the United States. The five waste types are low-level mixed waste, low-level waste, transuranic waste, high-level waste, and hazardous waste. The WM PEIS provides information on the impacts of various siting alternatives which the Department of Energy (DOE) will use to decide at which sites to locate additional treatment, storage, and disposal capacity for each waste type.Volume II is an integral part of the Office of Environmental Management''s (EM''s) Waste Management Programmatic Environmental Impact Statement (WM PEIS), which portrays the impacts of EM''s waste management activities at each of the 17 major DOE sites evaluated in the WM PEIS

  14. Estimation of fetal volume by magnetic resonance imaging and stereology.

    Science.gov (United States)

    Roberts, N; Garden, A S; Cruz-Orive, L M; Whitehouse, G H; Edwards, R H

    1994-11-01

    The current methods to monitor fetal growth in utero are based on ultrasound image measurements which, lacking a proper sampling methodology, may be biased to unknown degrees. The Cavalieri method of stereology guarantees the accurate estimation of the volume of an arbitrary object from a few systematic sections. Non-invasive scanning methods, and magnetic resonance imaging (MRI) in particular, are valuable tools to provide the necessary sections, and therefore offer interesting possibilities for unbiased quantification. This paper describes how to estimate fetal volume in utero with a coefficient of error of less than 5% in less than 5 min, from three or four properly sampled MRI scans. MRI was chosen because it does not use ionizing radiations on the one hand, and it offers a good image quality on the other. The impact of potential sources of bias such as fetal motion, chemical shift and partial voluming artefacts is discussed. The methods are illustrated on four subjects monitored between weeks 28 and 40 of gestation.

  15. NSLS-II filling pattern measurement

    International Nuclear Information System (INIS)

    Yong Hu; Dalesio, L.B.; Kiman Ha; Pinayev, I.

    2012-01-01

    Multi-bunch injection will be deployed at NSLS-II. High bandwidth diagnostic beam monitors with high speed digitizers are used to measure bunch-by-bunch charge variation. In order to minimize intensity-correlated orbit oscillations due to uneven bunch patterns, we need to measure the filling pattern (also named bunch pattern or bunch structure). This paper focuses on filling pattern measurements: how to measure bunch structure and make this information available in EPICS-based control system. This measurement requires combination of 3 types of beam monitors (Wall Current Monitor, Fast Current Transformer and Beam Position Monitor), data acquisition and controls (fast digitizer, EPICS software, etc.) and Event Timing system. High-bandwidth filling pattern monitor requires high-speed digitizer to sample its analog output signal. The evaluation results of commercial fast digitizer Agilent Acqiris and high bandwidth detector Bergoz FCT are presented. We have also tested the algorithm software for filling pattern measurement as well as the interface to event timing system. It appears that filling pattern measurement system is well understood and the tests for control hardware and software have given good results

  16. Electronic monitoring and voice prompts improve hand hygiene and decrease nosocomial infections in an intermediate care unit.

    Science.gov (United States)

    Swoboda, Sandra M; Earsing, Karen; Strauss, Kevin; Lane, Stephen; Lipsett, Pamela A

    2004-02-01

    To determine whether electronic monitoring of hand hygiene and voice prompts can improve hand hygiene and decrease nosocomial infection rates in a surgical intermediate care unit. Three-phase quasi-experimental design. Phase I was electronic monitoring and direct observation; phase II was electronic monitoring and computerized voice prompts for failure to perform hand hygiene on room exit; and phase III was electronic monitoring only. Nine-room, 14-bed intermediate care unit in a university, tertiary-care institution. All patient rooms, utility room, and staff lavatory were monitored electronically. All healthcare personnel including physicians, nurses, nursing support personnel, ancillary staff, all visitors and family members, and any other personnel interacting with patients on the intermediate care unit. All patients with an intermediate care unit length of stay >48 hrs were followed for nosocomial infection. Electronic monitoring during all phases, computerized voice prompts during phase II only. We evaluated a total of 283,488 electronically monitored entries into a patient room with 251,526 exits for 420 days (10,080 hrs and 3,549 patient days). Compared with phase I, hand hygiene compliance in patient rooms improved 37% during phase II (odds ratio, 1.38; 95% confidence interval, 1.04-1.83) and 41% in phase III (odds ratio, 1.41; 95% confidence interval, 1.07-1.84). When adjusting for patient admissions during each phase, point estimates of nosocomial infections decreased by 22% during phase II and 48% during phase III; when adjusting for patient days, the number of infections decreased by 10% during phase II and 40% during phase III. Although the overall rate of nosocomial infections significantly decreased when combining phases II and III, the association between nosocomial infection and individual phase was not significant. Electronic monitoring provided effective ongoing feedback about hand hygiene compliance. During both the voice prompt phase and post

  17. Implantable bladder volume sensor based on resistor ladder network composed of conductive hydrogel composite.

    Science.gov (United States)

    Mi Kyung Kim; Hyojung Kim; Jung, Yeon Su; Adem, Kenana M A; Bawazir, Sarah S; Stefanini, Cesare; Lee, Hyunjoo J

    2017-07-01

    An accurate bladder volume monitoring system is a critical component in diagnosis and treatment of urological disorders. Here, we report an implantable bladder volume sensor with a multi-level resistor ladder which estimates the bladder volume through discrete resistance values. Discretization allows the sensor output to be resilient to the long-term drift, hysteresis, and degradation of the sensor materials. Our sensor is composed of biocompatible polypyrrole/agarose hydrogel composite. Because Young's modulus of this composite is comparable to that of the bladder wall, the effect of mechanical loading of the sensor on the bladder movement is minimized which allows more accurate volume monitoring. We also demonstrate the patterning and molding capability of this material by fabrication various structures. Lastly, we successfully demonstrate the functionality of the multi-level resistor ladder sensor as a bladder volume sensor by attaching the sensor on the pig's bladder and observing the impedance change of the sensor.

  18. The use of satellite data for monitoring temporal and spatial patterns of fire: a comprehensive review

    Science.gov (United States)

    Lasaponara, R.

    2009-04-01

    Remotely sensed (RS) data can fruitfully support both research activities and operative monitoring of fire at different temporal and spatial scales with a synoptic view and cost effective technologies. "The contribution of remote sensing (RS) to forest fires may be grouped in three categories, according to the three phases of fire management: (i) risk estimation (before fire), (ii) detection (during fire) and (iii) assessment (after fire)" Chuvieco (2006). Relating each phase, wide research activities have been conducted over the years. (i) Risk estimation (before fire) has been mainly based on the use of RS data for (i) monitoring vegetation stress and assessing variations in vegetation moisture content, (ii) fuel type mapping, at different temporal and spatial scales from global, regional down to a local scale (using AVHRR, MODIS, TM, ASTER, Quickbird images and airborne hyperspectral and LIDAR data). Danger estimation has been mainly based on the use of AVHRR (onborad NOAA), MODIS (onboard TERRA and AQUA), VEGETATION (onboard SPOT) due to the technical characteristics (i.e. spectral, spatial and temporal resolution). Nevertheless microwave data have been also used for vegetation monitoring. (ii) Detection: identification of active fires, estimation of fire radiative energy and fire emission. AVHRR was one of the first satellite sensors used for setting up fire detection algorithms. The availbility of MODIS allowed us to obtain global fire products free downloaded from NASA web site. Sensors onboard geostationary satellite platforms, such as GOES, SEVIRI, have been used for fire detection, to obtain a high temporal resolution (at around 15 minutes) monitoring of active fires. (iii) Post fire damage assessment includes: burnt area mapping, fire emission, fire severity, vegetation recovery, fire resilience estimation, and, more recently, fire regime characterization. Chuvieco E. L. Giglio, C. Justice, 2008 Global charactrerization of fire activity: toward defining

  19. DNSSM: A Large Scale Passive DNS Security Monitoring Framework

    OpenAIRE

    Marchal , Samuel; François , Jérôme; Wagner , Cynthia; State , Radu; Dulaunoy , Alexandre; Engel , Thomas; Festor , Olivier

    2012-01-01

    International audience; We present a monitoring approach and the supporting software architecture for passive DNS traffic. Monitoring DNS traffic can reveal essential network and system level activity profiles. Worm infected and botnet participating hosts can be identified and malicious backdoor communications can be detected. Any passive DNS monitoring solution needs to address several challenges that range from architectural approaches for dealing with large volumes of data up to specific D...

  20. Idaho National Engineering Laboratory Waste Area Groups 1-7 and 10 Technology Logic Diagram. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, M.C.; Meservey, R.H.; Little, M.; Ferguson, J.S.; Gilmore, M.C.

    1993-09-01

    The Idaho National Engineering Laboratory (INEL) Technology Logic Diagram (TLD) was developed to provide a decision support tool that relates Environmental Restoration (ER) and Waste Management (WM) problems at the INEL to potential technologies that can remediate these problems. The TLD identifies the research, development, demonstration, testing, and evaluation needed to develop these technologies to a state that allows technology transfer and application to an environmental restoration need. It is essential that follow-on engineering and system studies be conducted to build on the output of this project. These studies will begin by selecting the most promising technologies identified in this TLD and finding an optimum mix of technologies that will provide a socially acceptable balance between cost and risk to meet the site windows of opportunity. The TLD consists of three separate volumes: Volume I includes the purpose and scope of the TLD, a brief history of the INEL Waste Area Groups, and environmental problems they represent. A description of the TLD, definitions of terms, a description of the technology evaluation process, and a summary of each subelement, is presented. Volume II describes the overall layout and development of the TLD in logic diagram format. This section addresses the environmental restoration of contaminated INEL sites. Volume III (this volume) provides the Technology Evaluation Data Sheets (TEDS) for Environmental Restoration and Waste Management (EM) activities that are reference by a TEDS code number in Volume II. Each of these sheets represents a single logic trace across the TLD. These sheets contain more detail than provided for technologies in Volume II. Data sheets are arranged alphanumerically by the TEDS code number in the upper right corner of each sheet.

  1. Ultrasound-assisted dispersive solid phase extraction of cadmium(II) and lead(II) using a hybrid nanoadsorbent composed of graphene and the zeolite clinoptilolite

    International Nuclear Information System (INIS)

    Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Shirkhanloo, Hamid; Rashidi, Ali Morad

    2015-01-01

    We describe a hybrid nanoadsorbent prepared by depositing graphene on the zeolite clinoptilolite by chemical vapor deposition. The resulting sorbent is well suited for the preconcentration of lead(II) and cadmium(II) by ultrasound-assisted dispersive micro solid–phase extraction. An extraction unit has been designed and manufactured that facilitates handling of small sample volumes. The effects of sample pH, amount of sorbent, concentration and volume of elution and time of ultrasonic bath were investigated. The nanoadsorbent was characterized by scanning electron microscopy, X-ray diffraction and energy dispersive X-ray microanalysis, all of which revealed the high surface area of the graphene sheets on the clinoptilolite. The extraction recoveries when using the new nanoadsorbent are 97 % (as opposed to a mere 10 % in case of clinoptilolite only). It is assumed that the graphene sheets located around the porous structure of clinoptilolite are acting as a barrier against macromolecules potentially existing in the sample matrices. The method was applied to the determination of lead and cadmium in water and human serum samples by electrothermal atomic absorption spectrometry. The detection limits were as low as 70 and 4 ng L −1 for Pb(II) and Cd(II), respectively. The accuracy of the method was underpinned by correct analysis of a standard reference material (SRM: 203105 Seronorm Trace Elements Serum L-2). (author)

  2. Biosensors and invasive monitoring in clinical applications

    CERN Document Server

    Córcoles, Emma P

    2013-01-01

    This volume examines the advances of invasive monitoring by means of biosensors and microdialysis. Physical and physiological parameters are commonly monitored in clinical settings using invasive techniques due to their positive outcome in patients’ diagnosis and treatment. Biochemical parameters, however, still rely on off-line measurements and require large pieces of equipment. Biosensing and sampling devices present excellent capabilities for their use in continuous monitoring of patients’ biochemical parameters. However, certain issues remain to be solved in order to ensure a more widespread use of these techniques in today’s medical practices.

  3. Small Lesion Size Is Associated with Sleep-Related Epilepsy in Focal Cortical Dysplasia Type II

    Directory of Open Access Journals (Sweden)

    Bo Jin

    2018-02-01

    Full Text Available ObjectiveTo investigate the neuroimaging and clinical features associated with sleep-related epilepsy (SRE in patients with focal cortical dysplasia (FCD type II.MethodsPatients with histopathologically proven FCD type II were included from three epilepsy centers. SRE was defined according to the video EEG findings and seizure history. Cortical surface reconstruction and volume calculation were performed using FreeSurfer. The lesions were manually delineated on T1 volumetric MRI using the ITK-SNAP software. The lesion volumes were normalized by the intracranial volume of each patient. The lesions were classified as small or large by placing a threshold based on quantitative (whether the lesion was detected on MRI report and qualitative (volume criteria.ResultsA total of 77 consecutive patients were included. Of them, 36 had SRE and 41 had non-SRE. An earlier age of epilepsy onset, high seizure frequency, regional interictal EEG findings, and favorable surgical outcome were characteristic in both groups. Small lesions were defined as those having a volume <3,217 mm3. In total, 60.9% of the patients with SRE (25/41 had small FCD lesion, which was significantly higher than the non-SRE group (9/34, 26.5%, p = 0.005. Small lesion size was the only predictor significantly associated with SRE in the overall type II group by multivariate analyses (p = 0.016. Although the proportion of patients who had frontal FCD and SRE was higher than non-frontal FCD (54.5 vs. 27.3%, p = 0.043, the relationship between SRE and lesion location was not confirmed by multivariate analysis. Thalamic volume and seizure semiology were not statistically different between the SRE and non-SRE group. The significant association between lesion size and SRE was reproducible in type IIb and IIa subgroups.SignificanceSRE is common in patients with FCD type II. Small FCD type II lesions are significantly associated with SRE. Although our findings cannot be applied to

  4. INEL environmental characterization report. Volume III. Appendices E-H

    International Nuclear Information System (INIS)

    1984-09-01

    This volume contains the following appendices: (1) INEL subsurface hydrology; (2) cultural resources assessment of two study areas on the INEL; (3) description of INEL facilities; and (4) effluent measurements and environmental monitoring programs

  5. Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

    Directory of Open Access Journals (Sweden)

    Jacob Griffith

    2018-03-01

    Full Text Available Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.

  6. Annual report on radioactive discharges and monitoring of the environment 1991. V. 1

    International Nuclear Information System (INIS)

    1992-01-01

    This Annual Report supplements and updates British Nuclear Fuel plc's Health and Safety and the Environment Annual Report by providing more detailed information on radioactive discharges, monitoring of the environment and critical groups doses. BNFL has published Annual Reports on Radioactive Discharges and Monitoring of the Environment since 1977. This year the report is again sub-divided into two complementary volumes. Volume I includes, for each of the Company's sites, annual data on radioactive discharges into the environment and the associated environmental monitoring programmes. Critical groups doses for each site are presented in summary tables at the beginning of each chapter. (author)

  7. Index to Nuclear Safety: a technical progress review by chrology, permuted title, and author, Volume 11(1) through Volume 20(6)

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W B; Passiakos, M

    1980-06-01

    This index to Nuclear Safety, a bimonthly technical progress review, covers articles published in Nuclear Safety, Volume II, No. 1 (January-February 1970), through Volume 20, No. 6 (November-December 1979). It is divided into three sections: a chronological list of articles (including abstracts) followed by a permuted-title (KWIC) index and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center (NSIC), covers all safety aspects of nuclear power reactors and associated facilities. Over 600 technical articles published in Nuclear Safety in the last ten years are listed in this index.

  8. Analysis of some nuclear waste management options. Volume II. Appendices

    International Nuclear Information System (INIS)

    Berman, L.E.; Ensminger, D.A.; Giuffre, M.S.; Koplik, C.M.; Oston, S.G.; Pollak, G.D.; Ross, B.I.

    1978-01-01

    This report describes risk analyses performed on that portion of a nuclear fuel cycle which begins following solidification of high-level waste. Risks associated with handling, interim storage and transportation of the waste are assessed, as well as the long term implications of disposal in deep mined cavities. The risk is expressed in terms of expected dose to the general population and peak dose to individuals in the population. This volume consists of appendices which provide technical details of the work performed

  9. Analysis of some nuclear waste management options. Volume II. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Berman, L.E.; Ensminger, D.A.; Giuffre, M.S.; Koplik, C.M.; Oston, S.G.; Pollak, G.D.; Ross, B.I.

    1978-10-10

    This report describes risk analyses performed on that portion of a nuclear fuel cycle which begins following solidification of high-level waste. Risks associated with handling, interim storage and transportation of the waste are assessed, as well as the long term implications of disposal in deep mined cavities. The risk is expressed in terms of expected dose to the general population and peak dose to individuals in the population. This volume consists of appendices which provide technical details of the work performed.

  10. Monitoring van dioxinen in koemelk in risicogebieden. Deelrapport II

    NARCIS (Netherlands)

    Kootstra PR; de Jong APJM; Liem AKD; Hoogerbrugge R; den Boer AC; Marsman JA; Hijman WC; den Hartog RS; van ' t Klooster HA

    1990-01-01

    In this report, results are given of a monitoring program on dioxin levels in cow's milk, over the period from June to August 1990, from dairy farms in the vicinity of municipal solid waste incinerators (MSWs) and a metal reclamation plant in the Netherlands. Levels are expressed in picograms

  11. [Part II: basic hemodynamic monitoring and the use of pulmonary artery catheter].

    Science.gov (United States)

    Dias, Fernando Suparregui; Rezende, Ederlon; Mendes, Ciro Leite; Réa-Neto, Alvaro; David, Cid Marcos; Schettino, Guilherme; Lobo, Suzana Margareth Ajeje; Barros, Alberto; Silva, Eliézer; Friedman, Gilberto; Amaral, José Luiz Gomes do; Park, Marcelo; Monachini, Maristela; Oliveira, Mirella Cristine de; Assunção, Murillo Santucci César; Akamine, Nelson; Mello, Patrícia Veiga C; Pereira, Renata Andréa Pietro; Costa Filho, Rubens; Araújo, Sebastião; Félix Pinto, Sérgio; Ferreira, Sérgio; Mitushima, Simone Mattoso; Agareno, Sydney; Brilhante, Yuzeth Nóbrega de Assis

    2006-03-01

    Monitoring of vital functions is one of the most important tools in the management of critically ill patients. Nowadays is possible to detect and analyze a great deal of physiologic data using a lot of invasive and non-invasive methods. The intensivist must be able to select and carry out the most appropriate monitoring technique according to the patient requirements and taking into account the benefit/risk ratio. Despite the fast development of non invasive monitoring techniques, invasive hemodynamic monitoring using Pulmonary Artery Catheter still is one of the basic procedures in Critical Care. The aim was to define recommendations about clinical utility of basic hemodynamic monitoring methods and the Use of Pulmonary Artery Catheter. Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty-five physicians and nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004. Recommendations were made based on 55 questions about the use of central venous pressure, invasive arterial pressure, pulmonary artery catheter and its indications in different settings. Evaluation of central venous pressure and invasive arterial pressure, besides variables obtained by the PAC allow the understanding of cardiovascular physiology that is of great value to the care of critically ill patients. However, the correct use of these tools is fundamental to achieve the benefits due to its use.

  12. Flame atomic absorption spectrometric determination of heavy metals in aqueous solution and surface water preceded by co-precipitation procedure with copper(II) 8-hydroxyquinoline

    Science.gov (United States)

    Ipeaiyeda, Ayodele Rotimi; Ayoade, Abisayo Ruth

    2017-12-01

    Co-precipitation procedure has widely been employed for preconcentration and separation of metal ions from the matrices of environmental samples. This is simply due to its simplicity, low consumption of separating solvent and short duration for analysis. Various organic ligands have been used for this purpose. However, there is dearth of information on the application of 8-hydroxyquinoline (8-HQ) as ligand and Cu(II) as carrier element. The use of Cu(II) is desirable because there is no contamination and background adsorption interference. Therefore, the objective of this study was to use 8-HQ in the presence of Cu(II) for coprecipitation of Cd(II), Co(II), Cr(III), Ni(II) and Pb(II) from standard solutions and surface water prior to their determinations by flame atomic absorption spectrometry (FAAS). The effects of pH, sample volume, amount of 8-HQ and Cu(II) and interfering ions on the recoveries of metal ions from standard solutions were monitored using FAAS. The water samples were treated with 8-HQ under the optimum experimental conditions and metal concentrations were determined by FAAS. The metal concentrations in water samples not treated with 8-HQ were also determined. The optimum recovery values for metal ions were higher than 85.0%. The concentrations (mg/L) of Co(II), Ni(II), Cr(III), and Pb(II) in water samples treated with 8-HQ were 0.014 ± 0.002, 0.03 ± 0.01, 0.04 ± 0.02 and 0.05 ± 0.02, respectively. These concentrations and those obtained without coprecipitation technique were significantly different. Coprecipitation procedure using 8-HQ as ligand and Cu(II) as carrier element enhanced the preconcentration and separation of metal ions from the matrix of water sample.

  13. Lunar Health Monitor (LHM)

    Science.gov (United States)

    Lisy, Frederick J.

    2015-01-01

    Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

  14. A Survey of Optometry Graduates to Determine Practice Patterns: Part II: Licensure and Practice Establishment Experiences.

    Science.gov (United States)

    Bleimann, Robert L.; Smith, Lee W.

    1985-01-01

    A summary of Part II of a two-volume study of optometry graduates conducted by the Association of Schools and Colleges of Optometry is presented. Part II includes the analysis of the graduates' licensure and practice establishment experiences. (MLW)

  15. Site Environmental Report for 2007 Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, Regina E.; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea

    2008-09-15

    The Site Environmental Report is an integrated report on Berkeley Lab's environmental programs to satisfy the requirements of DOE Order 231.1A, Environment, Safety, and Health Reporting. It summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2007. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory's environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities.

  16. Missouri Journal of Research in Music Education, Volume II, Number 5.

    Science.gov (United States)

    Hilton, Lewis B., Ed.

    1971-01-01

    The six articles presented in this journal are: I. Research in Action: The Transfer of Research in Music and Music Education into the Classroom by Jack R. Stephenson; II. Programmed Instruction and Music Education by Douglas L. Turpin; III. Music Education and the Blind by Joan Thief Gagnepain; IV. Improved Teaching Through the Use of the…

  17. Predicting adult pulmonary ventilation volume and wearing complianceby on-board accelerometry during personal level exposure assessments

    Science.gov (United States)

    Rodes, C. E.; Chillrud, S. N.; Haskell, W. L.; Intille, S. S.; Albinali, F.; Rosenberger, M. E.

    2012-09-01

    BackgroundMetabolic functions typically increase with human activity, but optimal methods to characterize activity levels for real-time predictions of ventilation volume (l min-1) during exposure assessments have not been available. Could tiny, triaxial accelerometers be incorporated into personal level monitors to define periods of acceptable wearing compliance, and allow the exposures (μg m-3) to be extended to potential doses in μg min-1 kg-1 of body weight? ObjectivesIn a pilot effort, we tested: 1) whether appropriately-processed accelerometer data could be utilized to predict compliance and in linear regressions to predict ventilation volumes in real-time as an on-board component of personal level exposure sensor systems, and 2) whether locating the exposure monitors on the chest in the breathing zone, provided comparable accelerometric data to other locations more typically utilized (waist, thigh, wrist, etc.). MethodsPrototype exposure monitors from RTI International and Columbia University were worn on the chest by a pilot cohort of adults while conducting an array of scripted activities (all volumes in-situ. For the subset of participants with complete data (n = 22), linear regressions were constructed (processed accelerometric variable versus ventilation rate) for each participant and exposure monitor type, and Pearson correlations computed to compare across scenarios. ResultsTriaxial accelerometer data were demonstrated to be adequately sensitive indicators for predicting exposure monitor wearing compliance. Strong linear correlations (R values from 0.77 to 0.99) were observed for all participants for both exposure sensor accelerometer variables against ventilation volume for recumbent, sedentary, and ambulatory activities with MET values ˜volume data. Computing accelerometric standard deviations allowed good sensitivity for compliance assessments even for sedentary activities. These pilot findings supported the hypothesis that a common linear

  18. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?

    Science.gov (United States)

    Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto

    2002-09-01

    Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore

  19. The EBR-II fuel cycle story

    International Nuclear Information System (INIS)

    Stevenson, C.E.

    1987-01-01

    This volume on the history of the Experimental Breeder Reactor (EBR) program and the Fuel Cycle Facility (FCF) offers both the historical perspective and ''reasons why'' the project was so successful. The operation of the FCF in conjunction with the EBR-II was prepared because of the unique nature of the pyrmetallurgical processing system that was demonstrated at the time. Following brief descriptions and histories of the EBR-I and EBR-II reactors, the FCF and its process requirements are described. The seven principal process steps are presented, including for each one, the development, equipment used, operating procedures, results, problems and other data. Scrap and waste disposition, analytical control, safety, management, and cost of the FCF are also included

  20. Optical System for Monitoring Net Occular Blood Flow, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Physical Sciences Inc. (PSI) proposes to develop a novel ophthalmic imaging platform for the characterization and monitoring of visual impairment observed in...