WorldWideScience

Sample records for monitoring system set

  1. A Rough Set-Based Effective State Identification Method of Multisensor Tool Condition Monitoring System

    Directory of Open Access Journals (Sweden)

    Nan Xie

    2014-06-01

    Full Text Available Multisensor improves the accuracy of machine tool condition monitoring system, which provides the critical feedback information to the manufacture process controller. Multisensor monitoring system needs to collect abundant data to employ attribute extraction, election, reduction, and classification to form the decision knowledge. A machine tool condition monitoring system has been built and the method of tool condition decision knowledge discovery is also presented. Multiple sensors include vibration, force, acoustic emission, and main spindle current. The novel approach engages rough theory as a knowledge extraction tool to work on the data that are obtained from both multisensor and machining parameters and then extracts a set of minimal state identification rules encoding the preference pattern of decision making by domain experts. By means of the knowledge acquired, the tool conditions are identified. A case study is presented to illustrate that the approach produces effective and minimal rules and provides satisfactory accuracy.

  2. Automatic Threshold Setting and Its Uncertainty Quantification in Wind Turbine Condition Monitoring System

    DEFF Research Database (Denmark)

    Marhadi, Kun Saptohartyadi; Skrimpas, Georgios Alexandros

    2015-01-01

    Setting optimal alarm thresholds in vibration based condition monitoring system is inherently difficult. There are no established thresholds for many vibration based measurements. Most of the time, the thresholds are set based on statistics of the collected data available. Often times...... not represent the whole operating conditions of a turbine, which results in uncertainty in the parameters of the fitted probability distribution and the thresholds calculated. In this study, Johnson, Normal, and Weibull distributions are investigated; which distribution can best fit vibration data collected...

  3. Using Johnson Distribution for Automatic Threshold Setting in Wind Turbine Condition Monitoring System

    Science.gov (United States)

    2014-12-23

    and (Crabtree, 2011). A case study of using vibration monitoring to detect and diag- nose a fault in the generator bearing of a wind turbine in a real...monitored in wind turbines (for vibration based CMS) are the generator, gearbox, main bearings, and tower. Usu- ally accelerometers are installed on these... vibration data continuously from each sensor. Dif- ferent vibration measurements are considered in monitoring different components of a wind turbine . To

  4. Performance of a Blood Glucose Monitoring System in a Point-of-Care Setting.

    Science.gov (United States)

    Ottiger, Cornelia; Gygli, Nicole; Huber, Andreas R; Fernandez-Tresguerres, Beatriz; Pardo, Scott; Petruschke, Thorsten

    2016-07-01

    This study assesses and demonstrates that CONTOUR® XT-BGMS (CXT-BGMS) complies with the requirements of the German (RiliBÄK) and Swiss (QUALAB) quality control guidelines for point-of-care testing (POCT) and fulfills the ISO15197:2013 accuracy limits criteria under the routine conditions of a hospital point-of care setting. This single-center study was conducted in Switzerland using 105 venous blood samples from hospitalized patients. Each sample was tested in comparison to the hexokinase reference method. Compliance with POCT guidelines was assessed by daily BGMS measurements using control solutions. Accuracy of CXT-BGMS according to ISO limits was 98.41%. All control measurements were within the limits defined by RiliBÄK (within ± 11% of target values and root mean square error [RMSE] within RMSE limits), and QUALAB (within ± 10% of target values).

  5. Using Johnson Distribution for Automatic Threshold Setting in Wind Turbine Condition Monitoring System

    DEFF Research Database (Denmark)

    Marhadi, Kun Saptohartyadi; Skrimpas, Georgios Alexandros

    2014-01-01

    not rep- resent the whole operating conditions of a turbine, which re- sults in uncertainty in the parameters of the fitted probabil- ity distribution and the thresholds calculated. In this study Johnson distribution is used to identify shape, location, and scale parameters of distribution that can best...... the underlying probability distribution that describes the data is not known. Choosing an incorrect distribution to describe the data and then setting up thresholds based on the chosen distribution could result in sub-optimal thresholds. Moreover, in wind turbine applications the collected data available may...... fit vibration data. This study shows that using Johnson distribution can elim- inate testing or fitting various distributions to the data, and have more direct approach to obtain optimal thresholds. To quantify uncertainty in the thresholds due to limited data, im- plementations with bootstrap method...

  6. Performance of a Blood Glucose Monitoring System in a Point-of-Care Setting

    Science.gov (United States)

    Ottiger, Cornelia; Gygli, Nicole; Huber, Andreas R.; Fernandez-Tresguerres, Beatriz; Pardo, Scott; Petruschke, Thorsten

    2016-01-01

    This study assesses and demonstrates that CONTOUR® XT-BGMS (CXT-BGMS) complies with the requirements of the German (RiliBÄK) and Swiss (QUALAB) quality control guidelines for point-of-care testing (POCT) and fulfills the ISO15197:2013 accuracy limits criteria under the routine conditions of a hospital point-of care setting. This single-center study was conducted in Switzerland using 105 venous blood samples from hospitalized patients. Each sample was tested in comparison to the hexokinase reference method. Compliance with POCT guidelines was assessed by daily BGMS measurements using control solutions. Accuracy of CXT-BGMS according to ISO limits was 98.41%. All control measurements were within the limits defined by RiliBÄK (within ± 11% of target values and root mean square error [RMSE] within RMSE limits), and QUALAB (within ± 10% of target values). PMID:26989068

  7. Feasibility Study for The Setting Up of a Safety System for Monitoring CO2 Storage at Prinos Field, Greece

    Science.gov (United States)

    Koukouzas, Nikolaos; Lymperopoulos, Panagiotis; Tasianas, Alexandros; Shariatipour, Seyed

    2016-10-01

    Geological storage of CO2 in subsurface geological structures can mitigate global warming. A comprehensive safety and monitoring system for CO2 storage has been undertaken for the Prinos hydrocarbon field, offshore northern Greece; a system which can prevent any possible leakage of CO2. This paper presents various monitoring strategies of CO2 subsurface movement in the Prinos reservoir, the results of a simulation of a CO2 leak through a well, an environmental risk assessment study related to the potential leakage of CO2 from the seafloor and an overall economic insight of the system. The results of the simulation of the CO2 leak have shown that CO2 reaches the seabed in the form of gas approximately 13.7 years, from the beginning of injection. From that point onwards the amount of CO2 reaching the seabed increases until it reaches a peak at around 32.9 years. During the injection period, the CO2 plume develops only within the reservoir. During the post-injection period, the CO2 reaches the seabed and develops side branches. These correspond to preferential lateral flow pathways of the CO2 and are more extensive for the dissolved CO2 than for the saturated CO2 gas. For the environmental risk assessment, we set up a model, using ArcGIS software, based on the use of data regarding the speeds of the winds and currents encountered in the region. We also made assumptions related to the flow rate of CO2. Results show that after a period of 10 days from the start of CO2 leakage the CO2 has reached halfway to the continental shores where the “Natura” protected areas are located. CO2 leakage modelling results show CO2 to be initially flowing along a preferential flow direction, which is towards the NE. However, 5 days after the start of leakage of CO2, the CO2 is also flowing towards the ENE. The consequences of a potential CO2 leak are considered spatially limited and the ecosystem is itself capable of recovering. We have tried to determine the costs necessary for the

  8. SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M; Kim, T; Kang, S; Kim, D; Kim, K; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by

  9. A miniaturized video system for monitoring the locomotor activity of walking Drosophila melanogaster in space and terrestrial settings.

    Science.gov (United States)

    Inan, Omer T; Etemadi, Mozziyar; Sanchez, Max E; Marcu, Oana; Bhattacharya, Sharmila; Kovacs, Gregory T A

    2009-02-01

    A novel method is presented for monitoring movement of Drosophila melanogaster (the fruit fly) in space. Transient fly movements were captured by a $60, 2.5-cm-cubed monochrome video camera imaging flies illuminated by a uniform light source. The video signal from this camera was bandpass filtered (0.3-10 Hz) and amplified by an analog circuit to extract the average light changes as a function of time. The raw activity signal output of this circuit was recorded on a computer and digitally processed to extract the fly movement "events" from the waveform. These events corresponded to flies entering and leaving the image and were used for extracting activity parameters such as interevent duration. The efficacy of the system in quantifying locomotor activity was evaluated by varying environmental temperature and measuring the activity level of the flies. The results of this experiment matched those reported in the literature.

  10. Wearable Health Monitoring Systems

    Science.gov (United States)

    Bell, John

    2015-01-01

    The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

  11. Tools for Distributed Systems Monitoring

    Directory of Open Access Journals (Sweden)

    Kufel Łukasz

    2016-11-01

    Full Text Available The management of distributed systems infrastructure requires dedicated set of tools. The one tool that helps visualize current operational state of all systems and notify when failure occurs is available within monitoring solution. This paper provides an overview of monitoring approaches for gathering data from distributed systems and what are the major factors to consider when choosing a monitoring solution. Finally we discuss the tools currently available on the market.

  12. Fish welfare assurance system: initial steps to set up an effective tool to safeguard and monitor farmed fish welfare at a company level.

    Science.gov (United States)

    van de Vis, J W; Poelman, M; Lambooij, E; Bégout, M-L; Pilarczyk, M

    2012-02-01

    The objective was to take a first step in the development of a process-oriented quality assurance (QA) system for monitoring and safeguarding of fish welfare at a company level. A process-oriented approach is focused on preventing hazards and involves establishment of critical steps in a process that requires careful control. The seven principles of the Hazard Analysis Critical Control Points (HACCP) concept were used as a framework to establish the QA system. HACCP is an internationally agreed approach for management of food safety, which was adapted for the purpose of safeguarding and monitoring the welfare of farmed fish. As the main focus of this QA system is farmed fish welfare assurance at a company level, it was named Fish Welfare Assurance System (FWAS). In this paper we present the initial steps of setting up FWAS for on growing of sea bass (Dicentrarchus labrax), carp (Cyprinus carpio) and European eel (Anguilla anguilla). Four major hazards were selected, which were fish species dependent. Critical Control Points (CCPs) that need to be controlled to minimize or avoid the four hazards are presented. For FWAS, monitoring of CCPs at a farm level is essential. For monitoring purposes, Operational Welfare Indicators (OWIs) are needed to establish whether critical biotic, abiotic, managerial and environmental factors are controlled. For the OWIs we present critical limits/target values. A critical limit is the maximum or minimum value to which a factor must be controlled at a critical control point to prevent, eliminate or reduce a hazard to an acceptable level. For managerial factors target levels are more appropriate than critical limits. Regarding the international trade of farmed fish products, we propose that FWAS needs to be standardized in aquaculture chains. For this standardization a consensus on the concept of fish welfare, methods to assess welfare objectively and knowledge on the needs of farmed fish are required.

  13. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  14. Flight Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I project will develop the Flight System Monitor which will use non-intrusive electrical monitoring (NEMO). The electronic system health of...

  15. A system utilizing radio frequency identification (RFID) technology to monitor individual rodent behavior in complex social settings.

    Science.gov (United States)

    Howerton, Christopher L; Garner, Joseph P; Mench, Joy A

    2012-07-30

    Pre-clinical investigation of human CNS disorders relies heavily on mouse models. However these show low predictive validity for translational success to humans, partly due to the extensive use of rapid, high-throughput behavioral assays. Improved assays to monitor rodent behavior over longer time scales in a variety of contexts while still maintaining the efficiency of data collection associated with high-throughput assays are needed. We developed an apparatus that uses radio frequency identification device (RFID) technology to facilitate long-term automated monitoring of the behavior of mice in socially or structurally complex cage environments. Mice that were individually marked and implanted with transponders were placed in pairs in the apparatus, and their locations continuously tracked for 24 h. Video observation was used to validate the RFID readings. The apparatus and its associated software accurately tracked the locations of all mice, yielding information about each mouse's location over time, its diel activity patterns, and the amount of time it was in the same location as the other mouse in the pair. The information that can be efficiently collected in this apparatus has a variety of applications for pre-clinical research on human CNS disorders, for example major depressive disorder and autism spectrum disorder, in that it can be used to quantify validated endophenotypes or biomarkers of these disorders using rodent models. While the specific configuration of the apparatus described here was designed to answer particular experimental questions, it can be modified in various ways to accommodate different experimental designs. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. An eye on safety. With patient safety a top goal, CIOs are embracing wireless monitoring systems that can provide busy clinicians with another set of eyes.

    Science.gov (United States)

    Gamble, Kate Huvane

    2009-10-01

    Under increased demands to improve patient safety, CIOs are deploying sophisticated wireless monitoring systems. Wireless monitors can interface with communication systems and EMRs through integration engines. Installing wireless patient monitoring requires a great deal of collaboration and planning among nursing, IT, biomed and other key departments. Sophisticated monitoring systems enable discreet data to be extracted from the hospital's EMR system and utilized for trending and clinical-decision support. Alarm systems can be customized to fit the needs of individual users and prevent alert fatigue.

  17. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2011

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  18. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2015

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  19. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2014

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  20. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2016

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  1. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2013

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  2. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2009

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  3. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2010

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  4. EPA Enforcement and Compliance History Online: Water Discharge Monitoring Report Data Sets for FY2012

    Data.gov (United States)

    U.S. Environmental Protection Agency — Integrated Compliance Information System (ICIS) National Pollutant Discharge Elimination System (NPDES) Discharge Monitoring Report (DMR) data sets for Clean Water...

  5. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  6. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  7. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  8. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  9. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  10. Monitoring polypharmacy in healthcare systems through a multi-setting survey: should we put more attention on long term care facilities?

    Directory of Open Access Journals (Sweden)

    Luca Arnoldo

    2016-12-01

    Full Text Available Background. Polypharmacy is a main issue of patient safety in all healthcare settings (i.e. increase adverse drug reactions and incidence of drug-drug interactions, etc.. The main object of the study was to evaluate the prevalence of polypharmacy and the appropriateness of drugs prescriptions in the regional health system (RHS of Friuli Venezia-Giulia Region, Italy. Design and methods. We carried out a point prevalence study in May 2014; 1582 patients ≥65 years were included from: 14 acute hospitals, 46 Long Term Care Facilities (LTCFs and 42 general practitioners’ (GPs clinics. Data analysis included the evaluation of potentially inappropriate prescriptions (PIPs taking Beers criteria as a reference. Results. Patients in therapy with 10 drugs or more were 13.5%: 15.2% in hospitals, 9.7% in GPs’ clinics and 15.6% in LTCFs. According to Beers criteria we identified 1152 PIPs that involved globally almost half of patients (46.0%: 41.9% in hospitals, 59.6% in LTCFs and 37.0% in GP’s clinics. The 53.9% of patients received at least one mainly kidney excreted drug; for these patients the evaluation of serum creatinine was overall present in the 87.7% (747/852: 96.4% in hospital ones, 87.5% in GPs’ clinics and 77.8% in LTCFs. LTCFs residents were significantly (P<0.05 more exposed to PIPs and less monitored for the renal function. Conclusions. A reliable estimation of the phenomenon in all the main healthcare settings is a necessary prerequisite to set tailored policies for facing polypharmacy within a RHS; the results showed the necessity to put a special attention on LTCFs.

  11. Swing Set Irrigation System

    Directory of Open Access Journals (Sweden)

    Ambe Verma

    2015-05-01

    Full Text Available ABSTRACT India is a vast country based on agriculture and irrigation is the most important factor for agriculture. In India there are many sources provide for irrigation. Every day new technologies are emerged in the world which brings a revolutionary change in the nature of this world. day by day the energy resources used by the large population of this world are coming on the last stage This project give the idea that how the other different form of energy can be used and implemented efficiently to overcome from this problem The aim of this project is to achieve the objective of energy lasting problem which is likely to be faced over in coming decades. Energy lasting is a big problem in India. This is faced by every people who live in the country. Swing energy is the form of energy. In this paper we have represented the methodology of swing energy using for rural area of application. This paper is all about Swing Set Water Pump in which the water pump will execute with the help of a swing set of canopy type. As we need a motor to operate the water pump but in this project we use the swing in the place of motor and we use oscillatory motion of swing in the place of rotating motion of a motor. Everybody has needed the energy at an increasing rate ever since he came on the Earth. Because of this lot of energy has been exhausted and wasted. All the member are dedicated the amount of their important time to participate in multiple meetings read and research for making the content to the report. We would especially like to thanks for the efficient condition of the entire Advisory member and their experiences. This study was initial and performed within the BUDDHA INSTITUTE OF TECHNOLOGY GIDA Gorakhpur the final report represents the labour and interest of the entire member working for this project. Finally we would like to thanks to all the member of our college workshop who helped us in manufacturing of this project model.

  12. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I STTR project will demonstrate the Aerospace System Monitor (ASM). This technology transforms the power distribution network in a spacecraft or aircraft...

  13. A grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin; /Fermilab; Nowack, Andreas; /Aachen, Tech. Hochsch.; Padhi, Sanjay; /UC, San Diego; Sarkar, Subir; /INFN, Pisa /Pisa, Scuola Normale Superiore

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  14. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  15. Fish welfare assurance system: initial steps to set up an effective tool to safeguard and monitor farmed fish welfare at a company level

    NARCIS (Netherlands)

    Vis, van de J.W.; Poelman, M.; Lambooij, E.; Bégout, M.L.; Pilarczyk, M.

    2012-01-01

    The objective was to take a first step in the development of a process-oriented quality assurance (QA) system for monitoring and safeguarding of fish welfare at a company level. A process-oriented approach is focused on preventing hazards and involves establishment of critical steps in a process tha

  16. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  17. Nekton Interaction Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-15

    The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonar devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).

  18. Vehicle chassis monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pisu, P.; Soliman, A.; Rizzoni, G. [Ohio State Univ., Columbus (United States). Center for Automotive Research

    2001-07-01

    Fault detection and isolation is becoming one of the most important aspects in vehicle control system design. In order to achieve this FDI schemes, particular vehicle subsystems integrated with a controller have been proposed. This paper introduces a new model-based fault detection and fault diagnosis method for monitoring the vehicle chassis performance. (orig.)

  19. Inductive System Monitors Tasks

    Science.gov (United States)

    2008-01-01

    The Inductive Monitoring System (IMS) software developed at Ames Research Center uses artificial intelligence and data mining techniques to build system-monitoring knowledge bases from archived or simulated sensor data. This information is then used to detect unusual or anomalous behavior that may indicate an impending system failure. Currently helping analyze data from systems that help fly and maintain the space shuttle and the International Space Station (ISS), the IMS has also been employed by data classes are then used to build a monitoring knowledge base. In real time, IMS performs monitoring functions: determining and displaying the degree of deviation from nominal performance. IMS trend analyses can detect conditions that may indicate a failure or required system maintenance. The development of IMS was motivated by the difficulty of producing detailed diagnostic models of some system components due to complexity or unavailability of design information. Successful applications have ranged from real-time monitoring of aircraft engine and control systems to anomaly detection in space shuttle and ISS data. IMS was used on shuttle missions STS-121, STS-115, and STS-116 to search the Wing Leading Edge Impact Detection System (WLEIDS) data for signs of possible damaging impacts during launch. It independently verified findings of the WLEIDS Mission Evaluation Room (MER) analysts and indicated additional points of interest that were subsequently investigated by the MER team. In support of the Exploration Systems Mission Directorate, IMS is being deployed as an anomaly detection tool on ISS mission control consoles in the Johnson Space Center Mission Operations Directorate. IMS has been trained to detect faults in the ISS Control Moment Gyroscope (CMG) systems. In laboratory tests, it has already detected several minor anomalies in real-time CMG data. When tested on archived data, IMS was able to detect precursors of the CMG1 failure nearly 15 hours in advance of

  20. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  1. Earth System Monitoring, Introduction

    Science.gov (United States)

    Orcutt, John

    This section provides sensing and data collection methodologies, as well as an understanding of Earth's climate parameters and natural and man-made phenomena, to support a scientific assessment of the Earth system as a whole, and its response to natural and human-induced changes. The coverage ranges from climate change factors and extreme weather and fires to oil spill tracking and volcanic eruptions. This serves as a basis to enable improved prediction and response to climate change, weather, and natural hazards as well as dissemination of the data and conclusions. The data collection systems include satellite remote sensing, aerial surveys, and land- and ocean-based monitoring stations. Our objective in this treatise is to provide a significant portion of the scientific and engineering basis of Earth system monitoring and to provide this in 17 detailed articles or chapters written at a level for use by university students through practicing professionals. The reader is also directed to the closely related sections on Ecological Systems, Introduction and also Climate Change Modeling Methodology, Introduction as well as Climate Change Remediation, Introduction to. For ease of use by students, each article begins with a glossary of terms, while at an average length of 25 print pages each, sufficient detail is presented for use by professionals in government, universities, and industries. The chapters are individually summarized below.

  2. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  3. Food systems in correctional settings

    DEFF Research Database (Denmark)

    Smoyer, Amy; Kjær Minke, Linda

    Food is a central component of life in correctional institutions and plays a critical role in the physical and mental health of incarcerated people and the construction of prisoners' identities and relationships. An understanding of the role of food in correctional settings and the effective...... management of food systems may improve outcomes for incarcerated people and help correctional administrators to maximize their health and safety. This report summarizes existing research on food systems in correctional settings and provides examples of food programmes in prison and remand facilities......, including a case study of food-related innovation in the Danish correctional system. It offers specific conclusions for policy-makers, administrators of correctional institutions and prison-food-service professionals, and makes proposals for future research....

  4. Monitoring Vegetation Phenological Cycles in Two Different Semi-Arid Environmental Settings Using a Ground-Based NDVI System: A Potential Approach to Improve Satellite Data Interpretation

    Directory of Open Access Journals (Sweden)

    Malika Baghzouz

    2010-04-01

    Full Text Available In semi-arid environmental settings with sparse canopy covers, obtaining remotely sensed information on soil and vegetative growth characteristics at finer spatial and temporal scales than most satellite platforms is crucial for validating and interpreting satellite data sets. In this study, we used a ground-based NDVI system to provide continuous time series analysis of individual shrub species and soil surface characteristics in two different semi-arid environmental settings located in the Great Basin (NV, USA. The NDVI system was a dual channel SKR-1800 radiometer that simultaneously measured incident solar radiation and upward reflectance in two broadband red and near-infrared channels comparable to Landsat-5 TM band 3 and band 4, respectively. The two study sites identified as Spring Valley 1 site (SV1 and Snake Valley 1 site (SNK1 were chosen for having different species composition, soil texture and percent canopy cover. NDVI time-series of greasewood (Sarcobatus vermiculatus from the SV1 site allowed for clear distinction between the main phenological stages of the entire growing season during the period from January to November, 2007. NDVI time series values were significantly different between sagebrush (Artemisia tridentata and rabbitbrush (Chrysothamnus viscidiflorus at SV1 as well as between the two bare soil types at the two sites. Greasewood NDVI from the SNK1 site produced significant correlations with chlorophyll index (r = 0.97, leaf area index (r = 0.98 and leaf xylem water potential (r = 0.93. Whereas greasewood NDVI from the SV1 site produced lower correlations (r = 0.89, r = 0.73, or non significant correlations (r = 0.32 with the same parameters, respectively. Total percent cover was estimated at 17.5% for SV1 and at 63% for SNK1. Results from this study indicated the potential capabilities of using this ground-based NDVI system to extract spatial and temporal details of soil and vegetation optical properties not possible

  5. Food systems in correctional settings

    DEFF Research Database (Denmark)

    Smoyer, Amy; Kjær Minke, Linda

    Food is a central component of life in correctional institutions and plays a critical role in the physical and mental health of incarcerated people and the construction of prisoners' identities and relationships. An understanding of the role of food in correctional settings and the effective mana......, including a case study of food-related innovation in the Danish correctional system. It offers specific conclusions for policy-makers, administrators of correctional institutions and prison-food-service professionals, and makes proposals for future research....

  6. CERN Safety System Monitoring - SSM

    CERN Document Server

    Hakulinen, T; Valentini, F; Gonzalez, J; Salatko-Petryszcze, C

    2011-01-01

    CERN SSM (Safety System Monitoring) [1] is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs, servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix [2], on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from handheld devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems.

  7. Monitoring drinking water, sanitation, and hygiene in non-household settings: Priorities for policy and practice.

    Science.gov (United States)

    Cronk, Ryan; Slaymaker, Tom; Bartram, Jamie

    2015-11-01

    Inadequate drinking water, sanitation, and hygiene (WaSH) in non-household settings, such as schools, health care facilities, and workplaces impacts the health, education, welfare, and productivity of populations, particularly in low and middle-income countries. There is limited knowledge on the status of WaSH in such settings. To address this gap, we reviewed international standards, international and national actors, and monitoring initiatives; developed the first typology of non-household settings; and assessed the viability of monitoring. Based on setting characteristics, non-household settings include six types: schools, health care facilities, workplaces, temporary use settings, mass gatherings, and dislocated populations. To-date national governments and international actors have focused monitoring of non-household settings on schools and health care facilities with comparatively little attention given to other settings such as workplaces and markets. Nationally representative facility surveys and national management information systems are the primary monitoring mechanisms. Data suggest that WaSH coverage is generally poor and often lower than in corresponding household settings. Definitions, indicators, and data sources are underdeveloped and not always comparable between countries. While not all countries monitor non-household settings, examples are available from countries on most continents suggesting that systematic monitoring is achievable. Monitoring WaSH in schools and health care facilities is most viable. Monitoring WaSH in other non-household settings would be viable with: technical support from local and national actors in addition to international organizations such as WHO and UNICEF; national prioritization through policy and financing; and including WaSH indicators into monitoring initiatives to improve cost-effectiveness. International consultations on targets and indicators for global monitoring of WaSH post-2015 identified non

  8. OpenSM Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    2015-04-17

    The OpenSM Monitoring System includes a collection of diagnostic and monitoring tools for use on Infiniband networks. The information this system gathers is obtained from a service, which in turn is obtained directly from the OpenSM subnet manager.

  9. Ecological Monitoring Information System (EMIS).

    Science.gov (United States)

    Fiene, Richard John; And Others

    A system for evaluating and monitoring child development projects, with possible computerization capabilities, was developed for the State of Pennsylvania in connection with 26 child development projects funded by the Appalachian Regional Commission. The Ecological Monitoring Information System (EMIS), provides a series of ecological measurement…

  10. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  11. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  12. An advanced joint inversion system for CO2 storage modeling with large date sets for characterization and real-time monitoring-enhancing storage performance and reducing failure risks under uncertainties

    Energy Technology Data Exchange (ETDEWEB)

    Kitanidis, Peter [Stanford Univ., CA (United States)

    2016-04-30

    As large-scale, commercial storage projects become operational, the problem of utilizing information from diverse sources becomes more critically important. In this project, we developed, tested, and applied an advanced joint data inversion system for CO2 storage modeling with large data sets for use in site characterization and real-time monitoring. Emphasis was on the development of advanced and efficient computational algorithms for joint inversion of hydro-geophysical data, coupled with state-of-the-art forward process simulations. The developed system consists of (1) inversion tools using characterization data, such as 3D seismic survey (amplitude images), borehole log and core data, as well as hydraulic, tracer and thermal tests before CO2 injection, (2) joint inversion tools for updating the geologic model with the distribution of rock properties, thus reducing uncertainty, using hydro-geophysical monitoring data, and (3) highly efficient algorithms for directly solving the dense or sparse linear algebra systems derived from the joint inversion. The system combines methods from stochastic analysis, fast linear algebra, and high performance computing. The developed joint inversion tools have been tested through synthetic CO2 storage examples.

  13. Unattended Monitoring System Design Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-07-08

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations.

  14. Engineering monitoring expert system's developer

    Science.gov (United States)

    Lo, Ching F.

    1991-01-01

    This research project is designed to apply artificial intelligence technology including expert systems, dynamic interface of neural networks, and hypertext to construct an expert system developer. The developer environment is specifically suited to building expert systems which monitor the performance of ground support equipment for propulsion systems and testing facilities. The expert system developer, through the use of a graphics interface and a rule network, will be transparent to the user during rule constructing and data scanning of the knowledge base. The project will result in a software system that allows its user to build specific monitoring type expert systems which monitor various equipments used for propulsion systems or ground testing facilities and accrues system performance information in a dynamic knowledge base.

  15. Systemic consultation and goal setting

    OpenAIRE

    Carr, Alan

    1993-01-01

    Over two decades of empirical research conducted within a positivist framework has shown that goal setting is a particularly useful method for influencing task performance in occupational and industrial contexts. The conditions under which goal setting is maximally effective are now clearly established. These include situations where there is a high level of acceptance and commitment, where goals are specific and challenging, where the task is relatively simple rather than ...

  16. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  17. Integrity monitoring in WLAN positioning systems

    Science.gov (United States)

    Yerubandi, Sri Phani; Kalgikar, Bhargav; Gunturu, Maheedhar; Akopian, David; Chen, Philip

    2009-05-01

    Indoor Positioning Systems using WLANs have become very popular in recent years. These systems are spawning a new class of applications like activity recognition, surveillance, context aware computing and location based services. While Global Positioning System (GPS) is the natural choice for providing navigation in outdoor environment, the urban environment places a significant challenge for positioning using GPS. The GPS signals can be significantly attenuated, and often completely blocked, inside buildings or in urban canyons. As the performance of GPS in indoor environments is not satisfactory, indoor positioning systems based on location fingerprinting of WLANs is being suggested as a viable alternative. The Indoor WLAN Positioning Systems suffer from several phenomena. One of the problems is the continual availability of access points, which directly affects the positioning accuracy. Integrity monitoring of WLAN localization, which computes WLAN positioning with different sets of access points is proposed as a solution for this problem. The positioning accuracy will be adequate for the sets which do not contain faulty or the access points which are offline, while the sets with such access points will fail and they will report random and inaccurate results. The proposed method identifies proper sets and identifies the rogue access points using prediction trajectories. The combination of prediction and correct access point set selection provides a more accurate result. This paper discusses about integrity monitoring method for WLAN devices and followed by how it monitors and developing the application on mobile platforms.

  18. Global integrated drought monitoring and prediction system.

    Science.gov (United States)

    Hao, Zengchao; AghaKouchak, Amir; Nakhjiri, Navid; Farahmand, Alireza

    2014-01-01

    Drought is by far the most costly natural disaster that can lead to widespread impacts, including water and food crises. Here we present data sets available from the Global Integrated Drought Monitoring and Prediction System (GIDMaPS), which provides drought information based on multiple drought indicators. The system provides meteorological and agricultural drought information based on multiple satellite-, and model-based precipitation and soil moisture data sets. GIDMaPS includes a near real-time monitoring component and a seasonal probabilistic prediction module. The data sets include historical drought severity data from the monitoring component, and probabilistic seasonal forecasts from the prediction module. The probabilistic forecasts provide essential information for early warning, taking preventive measures, and planning mitigation strategies. GIDMaPS data sets are a significant extension to current capabilities and data sets for global drought assessment and early warning. The presented data sets would be instrumental in reducing drought impacts especially in developing countries. Our results indicate that GIDMaPS data sets reliably captured several major droughts from across the globe.

  19. Wearable Health Monitoring Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  20. Wearable Health Monitoring Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  1. Solar Power Systems Web Monitoring

    CERN Document Server

    Kumar, Bimal Aklesh

    2011-01-01

    All over the world the peak demand load is increasing and the load factor is decreasing year-by-year. The fossil fuel is considered insufficient thus solar energy systems are becoming more and more useful, not only in terms of installation but monitoring of these systems is very crucial. Monitoring becomes very important when there are a large number of solar panels. Monitoring would allow early detection if the output falls below required level or one of the solar panel out of 1000 goes down. In this study the target is to monitor and control a developed solar panel by using available internet foundation. This web-enabled software will provide more flexibility over the system such as transmitting data from panel to the host computer and disseminating information to relevant stake holders barring any geographical barrier. The software would be built around web server with dynamic HTML and JAVA, this paper presents the preliminary design of the proposed system.

  2. Two-part set systems

    CERN Document Server

    Gerbner, Dániel; Lemons, Nathan; Mubayi, Dhruv; Palmer, Cory; Patkós, Balázs

    2011-01-01

    The two part Sperner theorem of Katona and Kleitman states that if $X$ is an $n$-element set with partition $X_1 \\cup X_2$, and $\\cF$ is a family of subsets of $X$ such that no two sets $A, B \\in \\cF$ satisfy $A \\subset B$ (or $B \\subset A$) and $A \\cap X_i=B \\cap X_i$ for some $i$, then $|\\cF| \\le {n \\choose \\lfloor n/2 \\rfloor}$. We consider variations of this problem by replacing the Sperner property with the intersection property and considering families that satisfiy various combinations of these properties on one or both parts $X_1$, $X_2$. Along the way, we prove the following new result which may be of independent interest: let $\\cF, \\cG$ be families of subsets of an $n$-element set such that $\\cF$ and $\\cG$ are both intersecting and cross-Sperner, meaning that if $A \\in \\cF$ and $B \\in \\cG$, then $A \

  3. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2006-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  4. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, Per Johan; Veltink, Petrus Hermanus; Roetenberg, Daniel

    2007-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for rec

  5. Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor)

    2017-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to control communication of data, via the bus, with each of the plurality of data acquisition modules.

  6. Hydraulic Diagnostic Monitoring System.

    Science.gov (United States)

    1981-03-02

    ALL THE LAWPS BY BLOOS, 36 ;FIRST THE P’JfS (5 LfIfS).THEN RESER4OIR 𔃾 LWS)’. 37 ;ETC LAWFS WILL STAY ON FOR V.2 SECOND THEN SEQUENCE 38 TO NEXT...NO CAIRY RERS O W6 238. 152 NOV F6a ,CR.L RUDE LAWP 86F 39 153 OUTL P1,A ;,ft LITE IT 154 5 156 157 158 ;RESERVOIR ROUTINE 159 ;IUE TO SETTING OF POT...SLBTRACT 214 i450 PSI FRO" THE RESULT TO TEST IF OUR PRECHFWGE PrESSURE IS ADEQUATE 215 ;FOR THE SYSTEMN- IF NOT iE LIGHT THE RAT LAWP 216 217 K-6 NADC

  7. Monitoring a petabyte scale storage system

    Energy Technology Data Exchange (ETDEWEB)

    Bakken, Jon; Berman, Eileen; Huang, Chih-Hao; Moibenko, Alexander; Petravick, Don; Zalokar, Michael; /Fermilab

    2004-12-01

    Fermilab operates a petabyte scale storage system, Enstore, which is the primary data store for experiments' large data sets. The Enstore system regularly transfers greater than 15 Terabytes of data each day. It is designed using a client-server architecture providing sufficient modularity to allow easy addition and replacement of hardware and software components. Monitoring of this system is essential to insure the integrity of the data that is stored in it and to maintain the high volume access that this system supports. The monitoring of this distributed system is accomplished using a variety of tools and techniques that present information for use by a variety of roles (operator, storage system administrator, storage software developer, user). Essential elements of the system are monitored: performance, hardware, firmware, software, network, data integrity. We will present details of the deployed monitoring tools with an emphasis on the different techniques that have proved useful to each role. Experience with the monitoring tools and techniques, what worked and what did not will be presented.

  8. BES Monitoring & Displaying System

    Institute of Scientific and Technical Information of China (English)

    MengWANG; BingyunZHANG; 等

    2001-01-01

    BES1 Monitoring & Displaying System(BESMDS)is projected to monitor and display the running status of DAQ and Slow Control systems of BES through the Web for worldwide accessing.It provides a real-time remote means of monitoring as well as an approach to study the environmental influence upon physical data taking.The system collects real-time data separately from BES online subsystems by network sockets and stores the data into a database.People can access the system through its web site.which retrieves data on request from the database and can display results in dynamically created images.Its web address in http:// besmds,ihep.ac.cn/

  9. On-Line Monitoring System of Operating Condition of the Diesel Generator Set for Air-Conditions of Passenger Train%铁路客车空调发电机组工况在线监控系统

    Institute of Scientific and Technical Information of China (English)

    马殷元; 姚闯

    2011-01-01

    To find abnormal operating conditions in time and avoid the diesel generator sets from been cracked-up due to it running with fault too long, the on-line monitoring system is designed. The system consists of moni toring devices installed on each train and a supervisory computer at the centre. The supervisory computer com municates with each device on-board in turn via Internet combined with GPRS( general packet radio service), and collects operating parameters of the generator set constantly. The supervisory computer automatically sends alarm messages to the trainman when paranormal data been detected. The system employs center to multi-terminal communicate mode with TCP to transfer the data. And no-microcomputer monitoring device is adopted in the system. The implemented system with simple structure and high reliability is cost-efficient and can transfer the information faster.%为及时发现铁路客车空调发电机组的异常工况,避免机组长时间带病运行和可能由此导致的设备报废或其他更大损失,设计了发电机组工况在线监控系统.系统由列车上的车载监控装置和一台地面监控中心计算机组成.二者借助通用分组无线业务和互联网结合方式通信,实现了客车运行中发电机组工作参数和报警信息的远程实时传输.系统监测到参数异常时通过车载声光报警、监控计算机声光报警和短信3种方式发出报警.监控系统数据通信传输层采用中心对多终端的TCP底层通信方式.车载监控装置采用无微机设计.实现的系统结构简单、成本低且信息反馈及时.

  10. Reactivity Monitoring of Accelerator-Driven Nuclear Reactor Systems

    NARCIS (Netherlands)

    Uyttenhove, W.

    2016-01-01

    This thesis provides a methodology and set-up of a reactivity monitoring tool for Accelerator-Driven Systems (ADS). The reactivity monitoring tool should guarantee the operation of an ADS at a safe margin from criticality. Robustness is assured in different aspects of the monitoring tool: the choice

  11. Reactivity Monitoring of Accelerator-Driven Nuclear Reactor Systems

    NARCIS (Netherlands)

    Uyttenhove, W.

    2016-01-01

    This thesis provides a methodology and set-up of a reactivity monitoring tool for Accelerator-Driven Systems (ADS). The reactivity monitoring tool should guarantee the operation of an ADS at a safe margin from criticality. Robustness is assured in different aspects of the monitoring tool: the choice

  12. Monitoring electro-magnetic field in urban areas: new set-ups and results

    Energy Technology Data Exchange (ETDEWEB)

    Lubritto, C.; Petraglia, A.; Paribello, G.; Formosi, R.; Rosa, M. de; Vetromile, C.; Palmieri, A.; D' Onofrio, A. [Seconda Universita di Napoli, Dipt. di Scienze Ambientali, Caserta (Italy); Di Bella, G.; Giannini, V. [Vector Group, Roma (Italy)

    2006-07-01

    In this paper two different set-ups for continuous monitoring of electromagnetic levels are presented: the first one (Continuous Time E.M.F. Monitoring System) is based upon a network of fixed stations, allowing a detailed field monitoring as function of the time; the second one (Mobile Measurements Units) resorts to portable stations mounted on standard bicycles, allowing a positional screening in limited time intervals. For both set-ups a particular attention has been paid to the data management, by means of tools like web geographic information systems (Web-Gis). Moreover the V.I.C.R.E.M./E.L.F. software has been used for a predictive analysis of the electromagnetic field levels along with the geo referenced data coming from the field measurements. Starting from these results it has been realized that there is a need for an efficient and correct action of monitoring and information/formation in this domain, where dis-information or bad information is very often spread in the population, in particular in a field where the process of the appreciation and assessment of risk does not necessarily make use of a rationale, technically-informed procedure, but the judgement is rather based on a personal feeling, which may derive from a limited, unstructured set of information, using a set of qualitative attributes rather than a quantity. (N.C.)

  13. Priority setting in the REACH system.

    Science.gov (United States)

    Hansson, Sven Ove; Rudén, Christina

    2006-04-01

    Due to the large number of chemicals for which toxicological and ecotoxicological information is lacking, priority setting for data acquisition is a major concern in chemicals regulation. In the current European system, two administrative priority-setting criteria are used, namely novelty (i.e., time of market introduction) and production volume. In the proposed Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) system, the novelty criterion is no longer used, and production volume will be the main priority-setting criterion for testing requirements, supplemented in some cases with hazard indications obtained from QSAR modelling. This system for priority setting has severe weaknesses. In this paper we propose that a multicriteria system should be developed that includes at least three additional criteria: chemical properties, results from initial testing in a tiered system, and voluntary testing for which efficient incentives can be created. Toxicological and decision-theoretical research is needed to design testing systems with validated priority-setting mechanisms.

  14. Power Transformer Intelligence Monitor System

    Institute of Scientific and Technical Information of China (English)

    Sun Jianshe; Shi Lei

    2006-01-01

    An auto-monitoring system has been created that could monitor the main parameter of power transformers. It reads data of V&I by precision rectifier circuit and amplifier, and converted electric energy into pulse signal by means of sensor technique and pulse converter circuit, it is sent into microcomputer to process, completed monitoring to power transformer parameters and running state by software system. It can register all kinds of key data, and provide all kinds of virtual technical data for managing sections and can auto-form all kinds of electric annual reports and monthly reports analysis graphs such as managing graphs. It notably improves the safety and reliability of transformer, with strong anti-jamming technique and unique function, it can be used on the transformers in railway' s self-closing lines and all kinds of transformer stations.

  15. Gabor systems on discrete periodic sets

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Due to its good potential for digital signal processing, discrete Gabor analysis has interested some mathematicians. This paper addresses Gabor systems on discrete periodic sets, which can model signals to appear periodically but intermittently. Complete Gabor systems and Gabor frames on discrete periodic sets are characterized; a sufficient and necessary condition on what periodic sets admit complete Gabor systems is obtained; this condition is also proved to be sufficient and necessary for the existence of sets E such that the Gabor systems generated by χE are tight frames on these periodic sets; our proof is constructive, and all tight frames of the above form with a special frame bound can be obtained by our method; periodic sets admitting Gabor Riesz bases are characterized; some examples are also provided to illustrate the general theory.

  16. Gabor systems on discrete periodic sets

    Institute of Scientific and Technical Information of China (English)

    LI YunZhang; LIAN QiaoFang

    2009-01-01

    Due to its good potential for digital signal processing,discrete Gabor analysis has inter ested some mathematicians.This paper addresses Gabor systems on discrete periodic sets,which can model signals to appear periodically but intermittently.Complete Gabor systems and Gabor frames on discrete periodic sets are characterized; a sufficient and necessary condition on what periodic sets admit complete Gabor systems is obtained; this condition is also proved to be sufficient and necessary for the existence of sets E such that the Gabor systems generated by XE are tight frames on these periodic sets; our proof is constructive,and all tight frames of the above form with a special frame bound can be obtained by our method; periodic sets admitting Gabor Riesz bases are characterized;some examples are also provided to illustrate the general theory.

  17. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  18. Phonocardiograph system monitors heart sounds

    Science.gov (United States)

    1966-01-01

    Phonocardiograph system monitors the mechanical activity of the heart in extreme environments. It uses a piezoelectric-crystal microphone with an integral preamplifier, and a signal conditioner having special frequency characteristics. The output signals can be recorded on tape, presented aurally, or transmitted telemetrically to a remote station.

  19. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Cortes-Gonzalez, Arely; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two photomultiplier in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator based readout system. Combined information from all systems allows to monitor and equalise the calorimeter r...

  20. Energy Monitoring System Berbasis Web

    Directory of Open Access Journals (Sweden)

    Novan Zulkarnain

    2013-12-01

    Full Text Available Government through the Ministry of Energy and Mineral Resources (ESDM encourages the energy savings at whole buildings in Indonesia. Energy Monitoring System (EMS is a web-based solution to monitor energy usage in a building. The research methods used are the analysis, prototype design and testing. EMSconsists of hardware which consists of electrical sensors, temperature-humidity sensor, and a computer. Data on EMS are designed using Modbus protocol, stored in MySQL database application, and displayed on charts through Dashboard on LED TV using PHP programming.

  1. Nonlinear Differential Systems with Prescribed Invariant Sets

    DEFF Research Database (Denmark)

    Sandqvist, Allan

    1999-01-01

    We present a class of nonlinear differential systems for which invariant sets can be prescribed.Moreover,we show that a system in this class can be explicitly solved if a certain associated linear homogeneous system can be solved.As a simple application we construct a plane autonomous system having...

  2. Expert system for traffic signal setting assistance

    Energy Technology Data Exchange (ETDEWEB)

    Zozaya-Gorostiza, C.; Hendrickson, C.

    1987-03-01

    An experimental knowledge-based expert system to assist in traffic signal setting for isolated intersections is presented. In contrast to existing computer aids, the system can be applied to intersections of highly irregular geometries. Algorithmic processes to evaluate signal settings and decision tables to identify traffic flow conflicts are invoked by the expert system; phase distribution of flows is performed by applying heuristic rules. The system was written in the OPS5 export system environment. Advantages and disadvantages of the expert system programming approach relative to conventional algorithmic processes in the traffic engineering domain are described.

  3. Data sets for snow cover monitoring and modelling from the National Snow and Ice Data Center

    Science.gov (United States)

    Holm, M.; Daniels, K.; Scott, D.; McLean, B.; Weaver, R.

    2003-04-01

    A wide range of snow cover monitoring and modelling data sets are pending or are currently available from the National Snow and Ice Data Center (NSIDC). In-situ observations support validation experiments that enhance the accuracy of remote sensing data. In addition, remote sensing data are available in near-real time, providing coarse-resolution snow monitoring capability. Time series data beginning in 1966 are valuable for modelling efforts. NSIDC holdings include SMMR and SSM/I snow cover data, MODIS snow cover extent products, in-situ and satellite data collected for NASA's recent Cold Land Processes Experiment, and soon-to-be-released ASMR-E passive microwave products. The AMSR-E and MODIS sensors are part of NASA's Earth Observing System flying on the Terra and Aqua satellites Characteristics of these NSIDC-held data sets, appropriateness of products for specific applications, and data set access and availability will be presented.

  4. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  5. 29 CFR 1954.2 - Monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System....

  6. Software Oriented Data Monitoring System

    CERN Document Server

    K, Phani Nandan

    2010-01-01

    This project "Software Oriented Data Monitoring System" deals with real time monitoring of patients' parameters like body temperature, heart rate etc. The parameters are checked at regular intervals and Short Messaging Service (SMS) is sent to concerned doctor regarding the measured values. If the obtained parameters are above or below critical values, an alert SMS is also sent to the concerned doctor. This system is very much useful in hospitals, which saves the valuable time of the doctor who otherwise will have to monitor the patients throughout the day. Here the analog data from the sensors is first converted into digital form and is fed to the parallel port of the computer. This data obtained is converted into useful parameters, which is monitored and checked for safe limits. Appropriate SMS is sent to the doctor depending on whether the request is from an alert or routine signal. This is possible by interfacing a mobile phone (Siemens c35i) to the serial port of the computer. The SMS is sent from the co...

  7. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  8. Slow Monitoring Systems for CUORE

    Science.gov (United States)

    Dutta, Suryabrata; Cuore Collaboration

    2016-09-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale neutrinoless double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS). The experiment is comprised of 988 TeO2 bolometric crystals arranged into 19 towers and operated at a temperature of 10 mK. We have developed slow monitoring systems to monitor the cryostat during detector installation, commissioning, data taking, and other crucial phases of the experiment. Our systems use responsive LabVIEW virtual instruments and video streams of the cryostat. We built a website using the Angular, Bootstrap, and MongoDB frameworks to display this data in real-time. The website can also display archival data and send alarms. I will present how we constructed these slow monitoring systems to be robust, accurate, and secure, while maintaining reliable access for the entire collaboration from any platform in order to ensure efficient communications and fast diagnoses of all CUORE systems.

  9. Hypoxia, Monitoring, and Mitigation System

    Science.gov (United States)

    2015-08-01

    When compared to max VO2 as derived from a person’s two-mile run an indication of personalized capacity state can be generated which can also be...Monitoring, Alert and Mitigation System HR Heart Rate HRC Heart Rate Complexity HW Hardware IDR Initial Design Review K Thousand m Meters max Maximum... reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of

  10. Hanford Site groundwater monitoring: Setting, sources and methods

    Energy Technology Data Exchange (ETDEWEB)

    M.J. Hartman

    2000-04-11

    Groundwater monitoring is conducted on the Hanford Site to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA); Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA); U.S. Department of Energy (DOE) orders; and the Washington Administrative Code. Results of monitoring are published annually (e.g., PNNL-11989). To reduce the redundancy of these annual reports, background information that does not change significantly from year to year has been extracted from the annual report and published in this companion volume. This report includes a description of groundwater monitoring requirements, site hydrogeology, and waste sites that have affected groundwater quality or that require groundwater monitoring. Monitoring networks and methods for sampling, analysis, and interpretation are summarized. Vadose zone monitoring methods and statistical methods also are described. Whenever necessary, updates to information contained in this document will be published in future groundwater annual reports.

  11. Coastwide Reference Monitoring System (CRMS)

    Science.gov (United States)

    2010-01-01

    In 1990, the U.S. Congress enacted the Coastal Wetlands Planning, Protection and Restoration Act (CWPPRA) in response to growing awareness of a land loss crisis in Louisiana. Projects funded by CWPPRA require monitoring and evaluation of project effectiveness, and there is also a need to assess the cumulative effects of all projects to achieve a sustainable coastal environment. In 2003, the Louisiana Office of Coastal Protection and Restoration (OCPR) and the U.S. Geological Survey (USGS) received approval from the CWPPRA Task Force to implement the Coastwide Reference Monitoring System (CRMS) as a mechanism to monitor and evaluate the effectiveness of CWPPRA projects at the project, region, and coastwide levels. The CRMS design implements a multiple reference approach by using aspects of hydrogeomorphic functional assessments and probabilistic sampling. The CRMS program is as dynamic as the coastal habitats it monitors. The program is currently funded through CWPPRA and provides data for a variety of user groups, including resource managers, academics, landowners, and researchers.

  12. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G; Salapura, Valentina

    2014-12-02

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  13. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  14. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  15. A design methodology for unattended monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    SMITH,JAMES D.; DELAND,SHARON M.

    2000-03-01

    The authors presented a high-level methodology for the design of unattended monitoring systems, focusing on a system to detect diversion of nuclear materials from a storage facility. The methodology is composed of seven, interrelated analyses: Facility Analysis, Vulnerability Analysis, Threat Assessment, Scenario Assessment, Design Analysis, Conceptual Design, and Performance Assessment. The design of the monitoring system is iteratively improved until it meets a set of pre-established performance criteria. The methodology presented here is based on other, well-established system analysis methodologies and hence they believe it can be adapted to other verification or compliance applications. In order to make this approach more generic, however, there needs to be more work on techniques for establishing evaluation criteria and associated performance metrics. They found that defining general-purpose evaluation criteria for verifying compliance with international agreements was a significant undertaking in itself. They finally focused on diversion of nuclear material in order to simplify the problem so that they could work out an overall approach for the design methodology. However, general guidelines for the development of evaluation criteria are critical for a general-purpose methodology. A poor choice in evaluation criteria could result in a monitoring system design that solves the wrong problem.

  16. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  17. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  18. Automatic respiration monitoring system; Shushin jotai no jido monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This is a system to recognize automatically status of a person in sleep including respiration stop, toss about in bed, and departure from the bed by performing animated image processing on images of the person in sleep as photographed by a camera, and by obtaining respiration waveforms from changes in the images of the breast. The system has been developed jointly by the Medical Department of Ehime University and Toshiba Engineering Company when commissioned from the Silver Service Promotion Association as a two-year project. The system requires no operation by an operator, can monitor the respiration during sleep on a real time basis from a completely non-restraint condition, and can be utilized for early discovery of crib death and/or apneic syndrome of aged persons and infants. Its effectiveness was verified by the field tests at a special facility for physically and mentally handicapped aged persons. The system was awarded with the first grand prize for an image recognition system from the Japan Automatic Recognition System Association. (translated by NEDO)

  19. Aggregating Hydrometeorological Data from International Monitoring Networks Across Earth's Largest Lake System to Quantify Uncertainty in Historical Water Budget Records, Improve Regional Water Budget Projections, and Differentiate Drivers Behind a Recent Record-Setting Surge in Water Levels

    Science.gov (United States)

    Gronewold, A.; Bruxer, J.; Smith, J.; Hunter, T.; Fortin, V.; Clites, A. H.; Durnford, D.; Qian, S.; Seglenieks, F.

    2015-12-01

    Resolving and projecting the water budget of the North American Great Lakes basin (Earth's largest lake system) requires aggregation of data from a complex array of in situ monitoring and remote sensing products that cross an international border (leading to potential sources of bias and other inconsistencies), and are relatively sparse over the surfaces of the lakes themselves. Data scarcity over the surfaces of the lakes is a particularly significant problem because, unlike Earth's other large freshwater basins, the Great Lakes basin water budget is (on annual scales) comprised of relatively equal contributions from runoff, over-lake precipitation, and over-lake evaporation. Consequently, understanding drivers behind changes in regional water storage and water levels requires a data management framework that can reconcile uncertainties associated with data scarcity and bias, and propagate those uncertainties into regional water budget projections and historical records. Here, we assess the development of a historical hydrometeorological database for the entire Great Lakes basin with records dating back to the late 1800s, and describe improvements that are specifically intended to differentiate hydrological, climatological, and anthropogenic drivers behind recent extreme changes in Great Lakes water levels. Our assessment includes a detailed analysis of the extent to which extreme cold winters in central North America in 2013-2014 (caused by the anomalous meridional upper air flow - commonly referred to in the public media as the "polar vortex" phenomenon) altered the thermal and hydrologic regimes of the Great Lakes and led to a record setting surge in water levels between January 2014 and December 2015.

  20. Monitoring Systems for Hydropower Plants

    Directory of Open Access Journals (Sweden)

    Damaschin Pepa

    2015-07-01

    Full Text Available One of the most important issue in hydro power industry is to determine the necessary degree of automation in order to improve the operation security. Depending upon the complexity of the system (the power plant equipment the automation specialist will build a philosophy of control following some general principals of security and operation. Helped by the modern digital equipment, today is relative easy to design a complete monitoring and supervising system including all the subparts of a hydro aggregate. A series of sensors and transducers specific for each auxiliary installation of the turbine and generator will be provided, together with a PLC or an industrial PC that will run an application software for implementing the security and control algorithms. The purpose of this paper is to offer a general view of these issues, providing a view of designing an automation & control and security system for hydro power plants of small, medium and big power.

  1. Integrated monitoring and surveillance system demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Aumeier, S.E.; Walters, G. [Argonne National Lab., Idaho Falls, ID (United States); Kotter, D.; Walrath, W.M.; Zamecnik, R.J. [Lockheed-Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-07-01

    We present a summary of efforts associated with the installation of an integrated system for the surveillance and monitoring of stabilized plutonium metals and oxides in long-term storage. The product of this effort will include a Pu storage requirements document, baseline integrated monitoring and surveillance system (IMSS) prototype and test bed that will be installed in the Fuel Manufacturing Facility (FMF) nuclear material vault at Argonne National Laboratory - West (ANL-W), and a Pu tracking database including data analysis capabilities. The prototype will be based on a minimal set of vault and package monitoring requirements as derived from applicable DOE documentation and guidelines, detailed in the requirements document, including DOE-STD-3013-96. The use of standardized requirements will aid individual sites in the selection of sensors that best suit their needs while the prototype IMSS, located at ANL-W, will be used as a test bed to compare and contrast sensor performance against a baseline integrated system (the IMSS), demonstrate system capabilities, evaluate potential technology gaps, and test new hardware and software designs using various storage configurations. With efforts currently underway to repackage and store a substantial quantity of plutonium and plutonium-bearing material within the DOE complex, this is an opportune time to undertake such a project. 4 refs.

  2. Switched Systems With Multiple Invariant Sets

    Science.gov (United States)

    2015-05-06

    Motor Control Mode Figure 1: Schematic of mode switching with non-equilibrium limit sets. with σ = 1. For a positive rate of convergence λ > 0, it...while utilizing steady-state control strategies for static balancing or tasks requiring fine motor control . Mode-switching also implicates a large...Switched Systems With Multiple Invariant SetsI Michael Dorothy, Soon-Jo Chung∗ Department of Aerospace Engineering, University of Illinois at Urbana

  3. Default settings of computerized physician order entry system order sets drive ordering habits

    Directory of Open Access Journals (Sweden)

    Jordan Olson

    2015-01-01

    Full Text Available Background: Computerized physician order entry (CPOE systems are quickly becoming ubiquitous, and groups of orders ("order sets" to allow for easy order input are a common feature. This provides a streamlined mechanism to view, modify, and place groups of related orders. This often serves as an electronic equivalent of a specialty requisition. A characteristic, of these order sets is that specific orders can be predetermined to be "preselected" or "defaulted-on" whenever the order set is used while others are "optional" or "defaulted-off" (though there is typically the option is to "deselect" defaulted-on tests in a given situation. While it seems intuitive that the defaults in an order set are often accepted, additional study is required to understand the impact of these "default" settings in an order set on ordering habits. This study set out to quantify the effect of changing the default settings of an order set. Methods: For quality improvement purposes, order sets dealing with transfusions were recently reviewed and modified to improve monitoring of outcome. Initially, the order for posttransfusion hematocrits and platelet count had the default setting changed from "optional" to "preselected." The default settings for platelet count was later changed back to "optional," allowing for a natural experiment to study the effect of the default selections of an order set on clinician ordering habits. Results: Posttransfusion hematocrit values were ordered for 8.3% of red cell transfusions when the default order set selection was "off" and for 57.4% of transfusions when the default selection was "preselected" (P < 0.0001. Posttransfusion platelet counts were ordered for 7.0% of platelet transfusions when the initial default order set selection was "optional," increased to 59.4% when the default was changed to "preselected" (P < 0.0001, and then decreased to 7.5% when the default selection was returned to "optional." The posttransfusion platelet

  4. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  5. New Approach for Setting a Management Criterion in Microbiological Monitoring Using Rapid Microbiological Methods.

    Science.gov (United States)

    Miyashita, Noe; Tanaka, Makoto; Gotoda, Ryusuke

    2015-01-01

    The application of rapid microbiological methods (RMM) to bacterial monitoring in pharmaceutical manufacturing processes is now a key topic, since timely microbiological data are critical for product release, continuous process improvement and quality control. An automated, highly sensitive detection system has been developed which can measure the amount of ATP in a sample in 2 h with one hundredfold more sensitive than the conventional ATP method. One of the major subjects for adoption and implementation of RMM is how to set the criterion value for practical microbial control. This value was conventionally been set by experimental rule and indicated as the number of colonies counted after incubation in a particular medium. We have adopted a new approach to set a criterion value which enables assessment in whether the status of the object is normal or not. By setting this criterion value, it is possible to conduct the microbiological control with the intended probability of false-positive and false-negative. In this approach the probability distribution model of the measurement value of each object in a normal status has been established by performing repetitive measurement of each object. We have suggested and verified the probability distribution form of the ATP measurement value using measurement data of the standard bacterial solution of Staphylococcus aureus. The theoretical value of the model was in good agreement with the actual measured value. The results suggest it is possible to set an applicable management criterion value using this model and to conduct new microbiological monitoring using RMM.

  6. System Administrator for LCS Development Sets

    Science.gov (United States)

    Garcia, Aaron

    2013-01-01

    The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.

  7. Intrusion Detection System: Security Monitoring System

    Directory of Open Access Journals (Sweden)

    ShabnamNoorani,

    2015-10-01

    Full Text Available An intrusion detection system (IDS is an ad hoc security solution to protect flawed computer systems. It works like a burglar alarm that goes off if someone tampers with or manages to get past other security mechanisms such as authentication mechanisms and firewalls. An Intrusion Detection System (IDS is a device or a software application that monitors network or system activities for malicious activities or policy violations and produces reports to a management station.Intrusion Detection System (IDS has been used as a vital instrument in defending the network from this malicious or abnormal activity..In this paper we are comparing host based and network based IDS and various types of attacks possible on IDS.

  8. Productivity Enhancement through Production Monitoring System

    OpenAIRE

    Prasad, Shiva H C; Rao, Potti Srinivasa; Gopalkrishna, B; Ahluwalia, Aakash

    2017-01-01

    A production monitoring system uses the real-time data while production is online. The real-time production monitoring systems are designed as means of auto data to the collection and monitoring the data via display boards. This study focuses on analysing the real-time production monitoring systems through trend analysis in production and over consumption of raw material controlling the over consumptions in a pen manufacturing industry. The methodology followed is through process flow diagram...

  9. Evolutionary Autonomous Health Monitoring System (EAHMS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For supporting NASA's Robotics, Tele-Robotics and Autonomous Systems Roadmap, we are proposing the "Evolutionary Autonomous Health Monitoring System" (EAHMS) for...

  10. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  11. Therapeutic Drug Monitoring of Venlafaxine in an Everyday Clinical Setting

    DEFF Research Database (Denmark)

    Hansen, Morten Rix; Kuhlmann, Ida Berglund; Pottegård, Anton

    2017-01-01

    Venlafaxine is a commonly used antidepressant agent. We aimed to provide detailed information on the associations between venlafaxine dose and concentrations of venlafaxine, by patient age and sex. From a therapeutic drug monitoring (TDM) database located at Odense University Hospital, Denmark, we......, and initiation of venlafaxine therapy in the elderly should be made cautiously and supported by drug measurements. This article is protected by copyright. All rights reserved....

  12. Standard hydrogen monitoring system equipment installation instructions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1996-09-27

    This document provides the technical specifications for the equipment fabrication, installation, and sitework construction for the Standard Hydrogen Monitoring System. The Standard Hydrogen Monitoring System is designed to remove gases from waste tank vapor space and exhaust headers for continual monitoring and remote sample analysis.

  13. Online monitoring of oil film using electrical capacitance tomography and level set method

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Q., E-mail: xueqian@tju.edu.cn; Ma, M. [College of Aeronautical Automation, Civil Aviation University of China, Tianjin 300300 (China); Sun, B. Y.; Cui, Z. Q.; Wang, H. X. [School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2015-08-15

    In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

  14. Online monitoring of oil film using electrical capacitance tomography and level set method

    Science.gov (United States)

    Xue, Q.; Sun, B. Y.; Cui, Z. Q.; Ma, M.; Wang, H. X.

    2015-08-01

    In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

  15. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-01-09

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program entails modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. The project continues to advance, but is behind the revised (14-month) schedule. Tasks 1-3 (Modeling, Specification and Design) are all essentially complete. The test bench for the Test and Evaluation (Tasks 4 & 5) has been designed and constructed. The design of the full-scale laboratory prototype and associated test equipment is complete and the components are out for manufacture. Barring any unforeseen difficulties, laboratory testing should be complete by the end of March, as currently scheduled. We anticipate the expenses through March to be approximately equal to those budgeted for Phase I.

  16. The ingestible thermal monitoring system

    Science.gov (United States)

    Cutchis, Protagoras N.; Hogrefe, Arthur F.; Lesho, Jeffery C.

    1988-01-01

    A thermal monitoring system for measuring body core temperatures was developed that contains an ingestible pill which is both commandable and rechargeable, and which uses magnetic induction for command and telemetry as well as for recharging. The pill electronics consist of a battery power source, a crystal-controlled oscillator that drives a small air coil, and a command detection circuit. The resulting 262-kHz magnetilc field can be easily detected from a distance of 1 m. The pill oscillator functions at voltages less than 1 V, supplied by a single Ni-Cd battery, which must be recharged after 72 h of continuous transmission. The pill can be recalibrated periodically to compensate for long-term drift.

  17. Systems metabolic engineering in an industrial setting.

    Science.gov (United States)

    Sagt, Cees M J

    2013-03-01

    Systems metabolic engineering is based on systems biology, synthetic biology, and evolutionary engineering and is now also applied in industry. Industrial use of systems metabolic engineering focuses on strain and process optimization. Since ambitious yields, titers, productivities, and low costs are key in an industrial setting, the use of effective and robust methods in systems metabolic engineering is becoming very important. Major improvements in the field of proteomics and metabolomics have been crucial in the development of genome-wide approaches in strain and process development. This is accompanied by a rapid increase in DNA sequencing and synthesis capacity. These developments enable the use of systems metabolic engineering in an industrial setting. Industrial systems metabolic engineering can be defined as the combined use of genome-wide genomics, transcriptomics, proteomics, and metabolomics to modify strains or processes. This approach has become very common since the technology for generating large data sets of all levels of the cellular processes has developed quite fast into robust, reliable, and affordable methods. The main challenge and scope of this mini review is how to translate these large data sets in relevant biological leads which can be tested for strain or process improvements. Experimental setup, heterogeneity of the culture, and sample pretreatment are important issues which are easily underrated. In addition, the process of structuring, filtering, and visualization of data is important, but also, the availability of a genetic toolbox and equipment for medium/high-throughput fermentation is a key success factor. For an efficient bioprocess, all the different components in this process have to work together. Therefore, mutual tuning of these components is an important strategy.

  18. Therapeutic drug monitoring of nevirapine in resource-limited settings.

    NARCIS (Netherlands)

    L'homme, R.F.A.; Muro, E.P.; Droste, J.A.H.; Wolters, L.R.; Kolmer, NW van Ewijk-Benek; Schimana, W.; Burger, D.M.

    2008-01-01

    BACKGROUND: We developed a simple and inexpensive thin-layer chromatography (TLC) assay for semiquantitative detection of saliva concentrations of nevirapine in resource-limited settings. The method was validated in an African target population. METHODS: Paired plasma and saliva nevirapine concentra

  19. Therapeutic drug monitoring of nevirapine in resource-limited settings.

    NARCIS (Netherlands)

    L'homme, R.F.A.; Muro, E.P.; Droste, J.A.H.; Wolters, L.R.; Kolmer, NW van Ewijk-Benek; Schimana, W.; Burger, D.M.

    2008-01-01

    BACKGROUND: We developed a simple and inexpensive thin-layer chromatography (TLC) assay for semiquantitative detection of saliva concentrations of nevirapine in resource-limited settings. The method was validated in an African target population. METHODS: Paired plasma and saliva nevirapine concentra

  20. ASHP national survey of pharmacy practice in hospital settings: Monitoring and patient education--2009.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2010-04-01

    Results of the 2009 ASHP national survey of pharmacy practice in hospital settings that pertain to monitoring and patient education are presented. A stratified random sample of pharmacy directors at 1364 general and children's medical-surgical hospitals in the United States were surveyed by mail. SDI Health supplied data on hospital characteristics; the survey sample was drawn from SDI's hospital database. The response rate was 40.5%. Virtually all hospitals (97.3%) had pharmacists regularly monitor medication therapy in some capacity; nearly half monitored 75% or more of their patients. Over 92% had pharmacists routinely monitor serum medication concentrations or their surrogate markers, and most hospitals allowed pharmacists to order initial serum concentrations (80.1%) and adjust dosages (79.2%). Interdisciplinary committees reviewed adverse drug events in 89.3% of hospitals. Prospective analysis was conducted by 66.2% of hospitals, and retrospective analysis was performed by 73.6%. An assessment of safety culture had been conducted by 62.8% of hospitals. Most hospitals assigned oversight for patient medication education to nursing (89.0%), but many hospitals (68.9%) reported that pharmacists provided medication education to 1-25% of patients. Computerized prescriber-order-entry systems with clinical decision support were in place in 15.4%, bar-code-assisted medication administration systems were used by 27.9%, smart infusion pumps were used in 56.2%, and complete electronic medical record systems were in place in 8.8% of hospitals. The majority of hospitals (64.7%) used an integrated pharmacy practice model using clinical generalists. Pharmacists were significantly involved in monitoring medication therapy. Pharmacists were less involved in medication education activities. Technologies to improve the use of medications were used in an increasing percentage of hospitals. Hospital pharmacy practice was increasingly integrated, with pharmacists having both

  1. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-01-28

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. The redesign and upgrade of the laboratory prototype was completed on schedule and it was assembled during the last period. Testing was begin during the first week of October. Initial results indicated that the dynamic range of the damping was less than predicted and that the maximum damping was also less than required. A number of possible explanations for these results were posited, and test equipment was acquired to evaluate the various hypotheses. Testing was just underway at the end of this period.

  2. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-10-29

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Phase II began on June 1, and the first month's effort were reported in the seventh quarterly report on the project.1 The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. The redesign and upgrade of the laboratory prototype was completed on schedule during this period, and assembly was complete at the end of this period. Testing will begin during the first week of October. This aspect of the project is thus approximately six weeks behind schedule. Design of the field prototype is progressing per schedule.

  3. Beryllium contamination and exposure monitoring in an inhalation laboratory setting.

    Science.gov (United States)

    Muller, Caroline; Audusseau, Séverine; Salehi, Fariba; Truchon, Ginette; Chevalier, Gaston; Mazer, Bruce; Kennedy, Greg; Zayed, Joseph

    2010-02-01

    Beryllium (Be) is used in several forms: pure metal, beryllium oxide, and as an alloy with copper, aluminum, or nickel. Beryllium oxide, beryllium metal, and beryllium alloys are the main forms present in the workplace, with inhalation being the primary route of exposure. Cases of workers with sensitization or chronic beryllium disease challenge the scientific community for a better understanding of Be toxicity. Therefore, a toxicological inhalation study using a murine model was performed in our laboratory in order to identify the toxic effects related to different particle sizes and chemical forms of Be. This article attempts to provide information regarding the relative effectiveness of the environmental monitoring and exposure protection program that was enacted to protect staff (students and researchers) in this controlled animal beryllium inhalation exposure experiment. This includes specific attention to particle migration control through intensive housekeeping and systematic airborne and surface monitoring. Results show that the protective measures applied during this research have been effective. The highest airborne Be concentration in the laboratory was less than one-tenth of the Quebec OEL (occupational exposure limit) of 0.15 microg/m(3). Considering the protection factor of 10(3) of the powered air-purifying respirator used in this research, the average exposure level would be 0.03 x 10(- 4) microg/m(3), which is extremely low. Moreover, with the exception of one value, all average Be concentrations on surfaces were below the Quebec Standard guideline level of 3 microg/100 cm(2) for Be contamination. Finally, all beryllium lymphocyte proliferation tests for the staff were not higher than controls.

  4. Monitored Geologic Repository Operations Monitoring and Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    E.F. Loros

    2000-06-29

    The Monitored Geologic Repository Operations Monitoring and Control System provides supervisory control, monitoring, and selected remote control of primary and secondary repository operations. Primary repository operations consist of both surface and subsurface activities relating to high-level waste receipt, preparation, and emplacement. Secondary repository operations consist of support operations for waste handling and treatment, utilities, subsurface construction, and other selected ancillary activities. Remote control of the subsurface emplacement operations, as well as, repository performance confirmation operations are the direct responsibility of the system. In addition, the system monitors parameters such as radiological data, air quality data, fire detection status, meteorological conditions, unauthorized access, and abnormal operating conditions, to ensure a safe workplace for personnel. Parameters are displayed in a real-time manner to human operators regarding surface and subsurface conditions. The system performs supervisory monitoring and control for both important to safety and non-safety systems. The system provides repository operational information, alarm capability, and human operator response messages during emergency response situations. The system also includes logic control to place equipment, systems, and utilities in a safe operational mode or complete shutdown during emergency response situations. The system initiates alarms and provides operational data to enable appropriate actions at the local level in support of emergency response, radiological protection response, evacuation, and underground rescue. The system provides data communications, data processing, managerial reports, data storage, and data analysis. This system's primary surface and subsurface operator consoles, for both supervisory and remote control activities, will be located in a Central Control Center (CCC) inside one of the surface facility buildings. The system

  5. The Technique of Building a Networked Manufacturing Process Monitoring System

    Institute of Scientific and Technical Information of China (English)

    XIE Yong; ZHANG Yu; YANG Musheng

    2006-01-01

    This paper introduces the constitute, structure and the software model of a set of networked manufacturing process monitoring system, using JAVA network technique to realize a set of three layer distributed manufacturing process monitoring system which is comprised with remote manage center, manufacturing process supervision center and the units of measure and control layer such as displacement sensor, the device of temperature measure and alarm etc. The network integration of the production management layer, the process control layer and the hard ware control layer is realized via using this approach. The design using object-oriented technique based on JAVA can easily transport to different operation systems with high performance of the expansibility.

  6. Computer Jet-Engine-Monitoring System

    Science.gov (United States)

    Disbrow, James D.; Duke, Eugene L.; Ray, Ronald J.

    1992-01-01

    "Intelligent Computer Assistant for Engine Monitoring" (ICAEM), computer-based monitoring system intended to distill and display data on conditions of operation of two turbofan engines of F-18, is in preliminary state of development. System reduces burden on propulsion engineer by providing single display of summary information on statuses of engines and alerting engineer to anomalous conditions. Effective use of prior engine-monitoring system requires continuous attention to multiple displays.

  7. Computer Jet-Engine-Monitoring System

    Science.gov (United States)

    Disbrow, James D.; Duke, Eugene L.; Ray, Ronald J.

    1992-01-01

    "Intelligent Computer Assistant for Engine Monitoring" (ICAEM), computer-based monitoring system intended to distill and display data on conditions of operation of two turbofan engines of F-18, is in preliminary state of development. System reduces burden on propulsion engineer by providing single display of summary information on statuses of engines and alerting engineer to anomalous conditions. Effective use of prior engine-monitoring system requires continuous attention to multiple displays.

  8. Online Status and Settings Monitoring for the LHC Collimators

    CERN Document Server

    Valentino, G; Jacquet, D; Redaelli, S; Veyrunes, E

    2014-01-01

    The Large Hadron Collider is equipped with 100 movable collimators. The LHC collimator control system is responsible for the accurate synchronization of around 400 axes of motion at the microsecond level, and with the precision of a few micrometers.

  9. Estimation of the patient monitor alarm rate for a quantitative analysis of new alarm settings.

    Science.gov (United States)

    de Waele, Stijn; Nielsen, Larry; Frassica, Joseph

    2014-01-01

    In many critical care units, default patient monitor alarm settings are not fine-tuned to the vital signs of the patient population. As a consequence there are many alarms. A large fraction of the alarms are not clinically actionable, thus contributing to alarm fatigue. Recent attention to this phenomenon has resulted in attempts in many institutions to decrease the overall alarm load of clinicians by altering the trigger thresholds for monitored parameters. Typically, new alarm settings are defined based on clinical knowledge and patient population norms and tried empirically on new patients without quantitative knowledge about the potential impact of these new settings. We introduce alarm regeneration as a method to estimate the alarm rate of new alarm settings using recorded patient monitor data. This method enables evaluation of several alarm setting scenarios prior to using these settings in the clinical setting. An expression for the alarm rate variance is derived for the calculation of statistical confidence intervals on the results.

  10. Digital Solution to Mining Image Monitor System

    Institute of Scientific and Technical Information of China (English)

    刘越男; 孙继平; 苏辉; 那景芳

    2001-01-01

    The thesis describes an advanced digital solution to mining digital image monitor system, which makes up the shortage of the traditional mining analog image monitor. It illustrates the system components and how to choose the encoder bandwidth of the system. The problem of image multicast and its solution in LAN are also discussed.

  11. Software For Monitoring VAX Computer Systems

    Science.gov (United States)

    Farkas, Les; Don, Ken; Lavery, David; Baron, Amy

    1994-01-01

    VAX Continuous Monitoring System (VAXCMS) computer program developed at NASA Headquarters to aid system managers in monitoring performances of VAX computer systems through generation of graphic images summarizing trends in performance metrics over time. VAXCMS written in DCL and VAX FORTRAN for use with DEC VAX-series computers running VMS 5.1 or later.

  12. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-04-27

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. As a result of the lower than expected performance of the MR damper noted last quarter, several additional tests were conducted. These dealt with possible causes of the lack of dynamic range observed in the testing: additional damping from the oil in the Belleville springs; changes in properties of the MR fluid; and, residual magnetization of the valve components. Of these, only the last was found to be significant. By using a laboratory demagnetization apparatus between runs, a dynamic range of 10:1 was achieved for the damper, more than adequate to produce the needed improvements in drilling. Additional modeling was also performed to identify a method of increasing the magnetic field in the damper. As a result of the above, several changes were made in the design. Additional circuitry was added to demagnetize the valve as the field is lowered. The valve was located to above the Belleville springs to reduce the load placed upon it and offer a greater range of materials for its construction. In addition, to further increase the field strength, the coils were relocated from the mandrel to the outer housing. At the end of the quarter, the redesign was complete and new parts were on order. The project is approximately three months behind schedule at this time.

  13. Design and Development of Patient Monitoring System

    Science.gov (United States)

    Hazwanie Azizulkarim, Azra; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    Patient monitoring system allows continuous monitoring of patient vital signs, support decision making among medical personnel and help enhance patient care. This system can consist of devices that measure, display and record human’s vital signs, including body temperature, heart rate, blood pressure and other health-related criteria. This paper proposes a system to monitor the patient’s conditions by monitoring the body temperature and pulse rate. The system consists of a pulse rate monitoring software and a wearable device that can measure a subject’s temperature and pulse rate only by using a fingertip. The device is able to record the measurement data and interface to PC via Arduino microcontroller. The recorded data can be viewed as a historical file or can be archived for further analysis. This work also describes the preliminary experimental results of the selected sensors to show the usefulness of the sensors for the proposed patient monitoring system.

  14. Monitoring by holographic radar systems

    Science.gov (United States)

    Catapano, Ilaria; Crocco, Lorenzo; Affinito, Antonio; Gennarelli, Gianluca; Soldovieri, Francesco

    2013-04-01

    Nowadays, radar technology represents a significant opportunity to collect useful information for the monitoring and conservation of critical infrastructures. Radar systems exploit the non-invasive interaction between the matter and the electromagnetic waves at microwave frequencies. Such an interaction allows obtaining images of the region under test from which one can infer the presence of potential anomalies such as deformations, cracks, water infiltrations, etc. This information turns out to be of primary importance in practical scenarios where the probed structure is in a poor state of preservation and renovation works must be planned. In this framework, the aim of this contribution is to describe the potentialities of the holographic radar Rascan 4/4000, a holographic radar developed by Remote Sensing Laboratory of Bauman Moscow State Technical University, as a non-destructive diagnostic tool capable to provide, in real-time, high resolution subsurface images of the sounded structure [1]. This radar provides holograms of hidden anomalies from the amplitude of the interference signal arising between the backscattered signal and a reference signal. The performance of the holographic radar is appraised by means of several experiments. Preliminary tests concerning the imaging below the floor and inside wood structures are carried out in controlled conditions at the Electromagnetic Diagnostic Laboratory of IREA-CNR. After, with reference to bridge monitoring for security aim, the results of a measurement campaign performed on the Musmeci bridge are presented [2]. Acknowledgments This research has been performed in the framework of the "Active and Passive Microwaves for Security and Subsurface imaging (AMISS)" EU 7th Framework Marie Curie Actions IRSES project (PIRSES-GA-2010-269157). REFERENCES [1] S. Ivashov, V. Razevig, I. Vasilyev, A. Zhuravlev, T. Bechtel, L. Capineri, The holographic principle in subsurface radar technology, International Symposium to

  15. Automated wind-icing monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Horokhov, Y.; Nekrasov, Y.; Turbin, S. [Donbas National Academy of Civil Engineering and Architecture, Makeyevka, Donetsk (Ukraine); Grimud, G. [NEC Ukrenergo, Kiev (Ukraine)

    2005-07-01

    The development of automated wind-icing monitoring systems (AWIMS) has increased the operational reliability of existing overhead lines through a more accurate prediction of icing events in the Ukraine. The systems are capable of operating without the presence of personnel, and allow operators to immediately obtain information about icing processes. The systems provide statistically significant sets of data for determining and predicting loading conditions, as well as combining measurements of icing mass, wind speed and direction, temperature and humidity. An outline of the principles of AWIMS was presented in paper, as well as a description of the system's architecture and operating principles. The monitoring system consists of an ice mass measuring device; a strain gauge sensor; a photoelectric pickup to determine perpendicular mean wind direction; and a wire simulator. The measuring devices are installed 10 meters above ground. Data is transmitted every 30 minutes to a central information office, where information is processed and stored. Details of the ultrasonic anemometer for wind measurements as well as the devices used for humidity and temperature measurement were presented. The AWIMS computer software measures 6 climatic parameters: wind speed; wind direction; air temperature; humidity; icing mass; and wind pressure on ice-covered wires. Results of a series of tests were presented which included a weather station data analysis and a comparison of the AWIMS with standard climatic loads. An analysis of overhead line failure statistical data was also conducted. Spatial icing distributions were used to calculate the threshold sensitivity for the AWIMS. As estimation of overhead lines density per square kilometer showed was made to determine placement of the systems. It was concluded that 8 more AWIMS will be installed in the following year. 3 refs., 10 figs.

  16. Intelligent monitoring system for intensive care units.

    Science.gov (United States)

    Nouira, Kaouther; Trabelsi, Abdelwahed

    2012-08-01

    We address in the present paper a medical monitoring system designed as a multi-agent based approach. Our system includes mainly numerous agents that act as correlated multi-agent sub-systems at the three layers of the whole monitoring infrastructure, to avoid non informative alarms and send effective alarms at time. The intelligence in the proposed monitoring system is provided by the use of time series technology. In fact, the capability of continuous learning of time series from the physiological variables allows the design of a system that monitors patients in real-time. Such system is a contrast to the classical threshold-based monitoring system actually present in the Intensive Care Units (ICUs) which causes a huge number of irrelevant alarms.

  17. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  18. Distributed Monitoring System Based on ICINGA

    CERN Document Server

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  19. Modernizing the monitoring of Mass Storage systems

    CERN Document Server

    Terrien, Alexandre

    2016-01-01

    The monitoring of a system is essential to ensure its efficiency. On a computer system, this monitoring is partly done via the analysis of log messages. The monitoring of CASTOR, a mass-storage system responsible for the storage of 150Pb of scientific data at CERN, was being done with tools developed by the IT-ST-FDO section. Those tools recently encountered some performance limitations due to the increase in the quantity of data produced by CERN's experiments. In this paper, I will describe how I managed to modernize CASTOR's monitoring tools by leveraging services centrally managed by CERN's IT department.

  20. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  1. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming;

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  2. Remote computer monitors corrosion protection system

    Energy Technology Data Exchange (ETDEWEB)

    Kendrick, A.

    Effective corrosion protection with electrochemical methods requires some method of routine monitoring that provides reliable data that is free of human error. A test installation of a remote computer control monitoring system for electrochemical corrosion protection is described. The unit can handle up to six channel inputs. Each channel comprises 3 analog signals and 1 digital. The operation of the system is discussed.

  3. Operation Safe Haven: an evaluation of health surveillance and monitoring in an acute setting.

    Science.gov (United States)

    Bennett, C; Mein, J; Beers, M; Harvey, B; Vemulpad, S; Chant, K; Dalton, C

    2000-02-17

    From May to June 1999, 3,920 ethnic Albanians from Kosovo arrived in Australia as part of Operation Safe Haven. These people were evacuated from refugee camps in the former Yugoslav Republic of Macedonia. Initial processing in Australia occurred at East Hills Reception Centre, and accommodation for the duration of stay was provided in eight Haven Centres in five States. The arrival of a large number of refugees in a short time frame is unprecedented in Australia. A health surveillance system was developed and critical health data were collected to assess health status and needs, plan care, monitor for potential outbreaks of communicable diseases, track service use, to meet international reporting requirements and document our response to this crisis. In this article the health surveillance system is evaluated and suggestions are offered for the formulation of specific guidelines necessary for health surveillance in acute settings.

  4. Developing a system for AMB Monitoring

    CERN Document Server

    Hancock, Thomas

    2015-01-01

    A monitoring system for the Associative Memory Boards (AMBs) of the Fast Tracker (FTK) is developed and tested. This system is able to read out status register values from AMBs and publish them to the Information Service (IS). The system is designed so as to be easily extensible to other boards of FTK, and this is demonstrated through an extension of the systems to be able to monitor FTK Auxiliary cards. Future work will involve extensions to other FTK boards and providing a system to read from IS and present the user with the monitoring data.

  5. Structural health monitoring using genetic fuzzy systems

    CERN Document Server

    Pawar, Prashant M

    2014-01-01

    The high profile of structural health monitoring (SHM) will add urgency to this detailed treatment of intelligent SHM development and implementation via the evolutionary system, which uses a genetic algorithm to automate the development of the fuzzy system.

  6. Storage monitoring systems for the year 2000

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C.; Pollock, R.

    1997-12-31

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000.

  7. Sport monitoring with smart wearable system.

    Science.gov (United States)

    Perego, Paolo; Moltani, Alessia; Andreoni, Giuseppe

    2012-01-01

    This work presents a new system for sport monitoring. The system was composed of a t-shirt with two textile electrodes and two devices for the acquisition, storage, processing and visualization of the signals. The systems allows monitoring both ECG signal (raw and processed heart-rate) and 3 axial acceleration (raw and step counter). The systems were tested in different conditions during some races; we report the results on three subjects during a skyrunning race.

  8. Set membership experimental design for biological systems

    Directory of Open Access Journals (Sweden)

    Marvel Skylar W

    2012-03-01

    Full Text Available Abstract Background Experimental design approaches for biological systems are needed to help conserve the limited resources that are allocated for performing experiments. The assumptions used when assigning probability density functions to characterize uncertainty in biological systems are unwarranted when only a small number of measurements can be obtained. In these situations, the uncertainty in biological systems is more appropriately characterized in a bounded-error context. Additionally, effort must be made to improve the connection between modelers and experimentalists by relating design metrics to biologically relevant information. Bounded-error experimental design approaches that can assess the impact of additional measurements on model uncertainty are needed to identify the most appropriate balance between the collection of data and the availability of resources. Results In this work we develop a bounded-error experimental design framework for nonlinear continuous-time systems when few data measurements are available. This approach leverages many of the recent advances in bounded-error parameter and state estimation methods that use interval analysis to generate parameter sets and state bounds consistent with uncertain data measurements. We devise a novel approach using set-based uncertainty propagation to estimate measurement ranges at candidate time points. We then use these estimated measurements at the candidate time points to evaluate which candidate measurements furthest reduce model uncertainty. A method for quickly combining multiple candidate time points is presented and allows for determining the effect of adding multiple measurements. Biologically relevant metrics are developed and used to predict when new data measurements should be acquired, which system components should be measured and how many additional measurements should be obtained. Conclusions The practicability of our approach is illustrated with a case study. This

  9. Set membership experimental design for biological systems

    Science.gov (United States)

    2012-01-01

    Background Experimental design approaches for biological systems are needed to help conserve the limited resources that are allocated for performing experiments. The assumptions used when assigning probability density functions to characterize uncertainty in biological systems are unwarranted when only a small number of measurements can be obtained. In these situations, the uncertainty in biological systems is more appropriately characterized in a bounded-error context. Additionally, effort must be made to improve the connection between modelers and experimentalists by relating design metrics to biologically relevant information. Bounded-error experimental design approaches that can assess the impact of additional measurements on model uncertainty are needed to identify the most appropriate balance between the collection of data and the availability of resources. Results In this work we develop a bounded-error experimental design framework for nonlinear continuous-time systems when few data measurements are available. This approach leverages many of the recent advances in bounded-error parameter and state estimation methods that use interval analysis to generate parameter sets and state bounds consistent with uncertain data measurements. We devise a novel approach using set-based uncertainty propagation to estimate measurement ranges at candidate time points. We then use these estimated measurements at the candidate time points to evaluate which candidate measurements furthest reduce model uncertainty. A method for quickly combining multiple candidate time points is presented and allows for determining the effect of adding multiple measurements. Biologically relevant metrics are developed and used to predict when new data measurements should be acquired, which system components should be measured and how many additional measurements should be obtained. Conclusions The practicability of our approach is illustrated with a case study. This study shows that our

  10. The design of remote temperature monitoring system

    Science.gov (United States)

    Li, Biqing; Li, Zhao; Wei, Liuren

    2017-08-01

    This design is made on the basis of the single-chip microcomputer remote temperature monitoring system. STC89C51RC is the main core part, this design use the sensor DHT11 of temperature or humidity and wireless transceiver NRF24L01 the temperature of the test site for long-range wireless measurement and monitoring. The design contains the main system and the small system, of which the main system can show the actual test site temperature and humidity values, voice broadcast, out of control and receive data alarm function; The small system has the function of temperature and humidity, temperature monitoring and sending data. After debugging, the user customizable alarm upper and lower temperature, when the temperature exceeds limit value, the main system of buzzer alarm immediately. The system has simple structure, complete functions and can alarm in time, it can be widely used remote temperature acquisition and monitoring of the site.

  11. Toward integrating a common nursing data set in home care to facilitate monitoring outcomes across settings.

    Science.gov (United States)

    Keenan, Gail; Stocker, Julia; Barkauskas, Violet; Treder, Marcy; Heath, Crystal

    2003-01-01

    The purpose of our research is to identify a realistic subset of North American Nursing Diagnosis Association (NANDA), Nursing Outcome Classification (NOC), and Nursing Interventions Classification (NIC) terms specific to the home care (HC) setting. A subset of 89 NOC outcomes were identified for study in HC through a baseline survey. Three research assistants then observed the care of 258 patients to whom the 89 NOC outcomes applied and recorded the associated NANDA and NIC terms. Follow-up surveys and focus groups were conducted with the nurses and research assistants. There were 81 different NANDA and 226 NIC labels used to describe study patients' care. Only 36 of the 89 NOC labels studied were deemed clinically useful for HC. We found that expert opinion about terminology usage before actual experience under practice conditions is unreliable.

  12. The CERN GSM monitoring system

    CERN Document Server

    Ghabrous, C

    2010-01-01

    This paper presents the way CERN has approached the problem of monitoring its own GSM infrastructure, especially in the Large Hadron Collider (LHC) accelerator tunnel and other underground facilities, where a leaky feeder cable carries mobile phone signals, and where this technology is the only means for inter-personnel communications

  13. Monitoring of distributed systems using historical debuggers

    Science.gov (United States)

    Komorowski, Michał

    2016-09-01

    Historical debuggers are tools that give insight into the history of program execution. This functionality is usually achieved by recording logs (execution traces). There are many tools of this kind but only limited number of them is capable of monitoring of distributed systems. It is a serious problem as the majority of contemporary information systems has distributed nature. This paper shows how to monitor and trace distributed systems using historical debuggers that were designed to work locally. The proposed concept consists of an approach for the correlation of execution traces that were recorded on different nodes of a distributed system that was monitored.

  14. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  15. Developing Automatic System Monitoring Solution for Accanto Systems Customer Care

    OpenAIRE

    Mikkola, Markku

    2015-01-01

    The goal of the development work was to document the requirements, to develop and deploy an automatic system monitoring solution for Accanto Systems Customer Care. This final report describes Icinga Core as the backbone of the monitoring solution and presents the actual use case that was implemented for Accanto Systems. The client for this work was Accanto Systems Customer Care department which had been suffering a long time with high work load due to increased basic system monitoring tas...

  16. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  17. Analyzing the characteristics of 6 MV photon beam at low monitor unit settings

    Directory of Open Access Journals (Sweden)

    L Nithya

    2016-01-01

    Full Text Available Analyzing the characteristics of a low monitor unit (MU setting is essential, particularly for intensity-modulated techniques. Intensity modulation can be achieved through intensity-modulated radiotherapy (IMRT or volumetric-modulated arc therapy (VMAT. There is possibility for low MUs in the segments of IMRT and VMAT plans. The minimum MU/segment must be set by the physicist in the treatment planning system at the time of commissioning. In this study, the characteristics such as dose linearity, stability, flatness, and symmetry of 6 MV photon beam of a Synergy linear accelerator at low MU settings were investigated for different dose rates. The measurements were performed for Synergy linear accelerator using a slab phantom with a FC65-G chamber and Profiler 2. The MU linearity was studied for 1–100 MU using a field size of 10 cm ×10 cm. The linearity error for 1 MU was 4.2%. Flatness of the beam was deteriorated in 1 MU condition. The beam stability and symmetry was well within the specification. Using this study, we conclude that the treatment delivered with <3 MU may result in uncertainty in dose delivery. To ensure the correct dose delivery with less uncertainty, it is recommended to use ≥3 MU as the minimum MU per segment in IMRT and VMAT plans.

  18. Implant evaluation of an insertable cardiac monitor outside the electrophysiology lab setting.

    Directory of Open Access Journals (Sweden)

    Roman Pachulski

    Full Text Available BACKGROUND: To date, insertable cardiac monitors (ICM have been implanted in the hospital without critical evaluation of other potential settings. Providing alternatives to in-hospital insertion may increase access to ICM, decrease waiting times for patients awaiting diagnosis, and reduce hospital resources. METHODS: This was a prospective, non-randomized, clinical trial involving nine clinical sites throughout the United States designed to assess the feasibility of ICM implants in a non-hospital setting. Other than the Reveal® ICM, implant supplies and techniques were left to physician discretion in patients who met indications. Patients were followed up to 90 days post-implant. The primary objective was to characterize the number of procedure-related adverse events that required surgical intervention within 90 days. RESULTS: Sixty-five patients were implanted at nine out-of-hospital sites. The insertion procedure was well tolerated by all patients. There were no deaths, systemic infections or endocarditis. There were two (3% procedure-related adverse events requiring device explant and four (6% adverse events not requiring explant. ICM use led to 16 diagnoses (24.6% with 9 patients proceeding to alternate cardiac device implants during the course of the 90-day follow up. CONCLUSION: Out-of-hospital ICM insertion can be accomplished with comparable procedural safety and represents a reasonable alternative to the in-hospital setting. CLINICALTRIALS.GOV REGISTRATION NUMBER: NCT01168427.

  19. A conceptual framework for intelligent monitoring systems

    Science.gov (United States)

    Juliano, Thomas; Meegoda, Jay; Niver, Edip; Watts, Daniel; Wadhawan, Sameer; Finlayson, Richard

    2005-05-01

    This paper discusses the conceptual development of a continuously monitored intelligent system for underground infrastructure. The proposed sensors are based on advanced coupling and refinement of several technologies: electrically conducting composite pipe (ECCP), electrochemical impedance spectroscopy (EIS) and time domain reflectometry (TDR). A significant benefit gleaned from the combination of these technologies is that the resulting system may be used on non-metallic, as well as, metallic pipes. In addition, the synergism of the technologies obtains the maximum information regarding defect location and characterization. The monitoring signal, waveguides, and damage sensor are also discussed, as well as, the data fusion, dynamic modeling and simulation requirements for the intelligent monitoring system.

  20. Research on monitoring system for slope deformation

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-sheng; ZHANG Xue-zhuang; WANG Ai-gong

    2007-01-01

    The monitoring system for slope deformation which bases on Leica (TCA series)was researched and developed. This system consists of electronic total stations, high precision thermometer, digital barometer, photoelectric frequency adjustor and other related instruments and data collection and processing software. The system can monitor a series of targets automatically to obtain accurate data of distance at predetermined time, besides,it can timely display targets' coordinates and deformation value, velocity, etc. in graph as well. To compare of the results of different monitoring time, we can find the problems of mine slope deformation rapidly and accurately.

  1. Test Results of a Phi Monitoring System

    CERN Document Server

    Figueroa, Carlos; Burgos, C; Ferrrando, A; Matorras, Francisco; Molinero, Antonio; Rodriguo, T; Shvachkin, V

    1997-01-01

    The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).

  2. OVERSEER: An Expert System Monitor for the Psychiatric Hospital

    Science.gov (United States)

    Bronzino, Joseph D.; Morelli, Ralph A.; Goethe, John W.

    1988-01-01

    In order to improve patient care, comply with regulatory guidelines and decrease potential liability, psychiatric hospitals and clinics have been searching for computer systems to monitor the management and treatment of patients. This paper describes OVERSEER: a knowledge based system that monitors the treatment of psychiatric patients in real time. Based on procedures and protocols developed in the psychiatric setting, OVERSEER monitors the clinical database and issues alerts when standard clinical practices are not followed or when laboratory results or other clinical indicators are abnormal. Written in PROLOG, OVERSEER is designed to interface directly with the hospital's database, and, thereby utilizes all available pharmacy and laboratory data. Moreover, unlike the interactive expert systems developed for the psychiatric clinic, OVERSEER does not require extensive data entry by the clinician. Consequently, the chief benefit of OVERSEER's monitoring approach is the unobtrusive manner in which it evaluates treatment and patient responses and provides information regarding patient management.

  3. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  4. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing...

  5. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  6. Data processing for water monitoring system

    Science.gov (United States)

    Monford, L.; Linton, A. T.

    1978-01-01

    Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

  7. Macroeconomic Effects In Centralized And Decentralized Wage Setting Systems

    OpenAIRE

    Sorolla, Valeri

    2000-01-01

    We present a model of a monetary economy with two systems of wage setting: a decentralized system and a centralized system. In the decentralized system there is a union per firm that sets the firm's wage. In the centralized system there is a unique union that sets a common wage for all firms. We find that, when there is unemployment, the equilibrium wage set in the centralized wage setting system is lower than the one set in the decentralized wage setting and that both depend on the size of t...

  8. A plasma process monitor/control system

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J.O.; Ward, P.P.; Smith, M.L. [Sandia National Labs., Albuquerque, NM (United States); Markle, R.J. [Advanced Micro Devices, Inc., Austin, TX (United States)

    1997-08-01

    Sandia National Laboratories has developed a system to monitor plasma processes for control of industrial applications. The system is designed to act as a fully automated, sand-alone process monitor during printed wiring board and semiconductor production runs. The monitor routinely performs data collection, analysis, process identification, and error detection/correction without the need for human intervention. The monitor can also be used in research mode to allow process engineers to gather additional information about plasma processes. The plasma monitor can perform real-time control of support systems known to influence plasma behavior. The monitor can also signal personnel to modify plasma parameters when the system is operating outside of desired specifications and requires human assistance. A notification protocol can be selected for conditions detected in the plasma process. The Plasma Process Monitor/Control System consists of a computer running software developed by Sandia National Laboratories, a commercially available spectrophotometer equipped with a charge-coupled device camera, an input/output device, and a fiber optic cable.

  9. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.

    Science.gov (United States)

    Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk

    2016-03-11

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.

  10. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Sungjun Kwon

    2016-03-01

    Full Text Available In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR and heart rate variability (HRV, to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1 upgrading the sensor device; (2 improving the feature extraction process; and (3 evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use.

  11. Research and implementation of road monitoring GIS system

    Science.gov (United States)

    Yu, Jia; Wu, Jianping; Yi, Min

    2007-06-01

    Based on the analysis of the shortcomings of the traditional video monitoring system, the paper presents an efficient road monitoring system based on GIS technology, named Road Monitoring GIS (RMGIS) System. The basic framework of the system modules is set out. The key technology and implementation of the special function are highlighted put forward. The paper takes a new interpretation of the buffer zone, topological network, geocoding and explains the construct method of some mathematical model. Advanced functions such as road topological network, moving object database and adaptive image recognition are also explored and studied in a certain extent. Now the system has been successfully applied to the road management in Shanghai urban area, some intelligent function will be implemented in the follow-up project.

  12. A System for Monitoring Affective Objectives.

    Science.gov (United States)

    Hughes, Abby L.; Frommer, Karen

    1982-01-01

    Based on the belief that affective education cannot be left to an informal process of "warm fuzzies," the system described here is a structured instructional program with specific affective objectives and a scale for monitoring achievement. (Author/JM)

  13. Automatic calorimetry system monitors RF power

    Science.gov (United States)

    Harness, B. W.; Heiberger, E. C.

    1969-01-01

    Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

  14. Modular biowaste monitoring system conceptual design

    Science.gov (United States)

    Fogal, G. L.

    1974-01-01

    The objective of the study was to define requirements and generate a conceptual design for a Modular Biowaste Monitoring System for specifically supporting shuttle life science experimental and diagnostic programs.

  15. Class 3 Tracking and Monitoring System Report

    Energy Technology Data Exchange (ETDEWEB)

    Safely, Eugene; Salamy, S. Phillip

    1999-11-29

    The objective of Class 3 tracking system are to assist DOE in tracking and performance and progress of these projects and to capture the technical and financial information collected during the projects' monitoring phase. The captured information was used by DOE project managers and BDM-Oklahoma staff for project monitoring and evaluation, and technology transfer activities. The proposed tracking system used the Class Evaluation Executive Report (CLEVER), a relation database for storing and disseminating class project data; GeoGraphix, a geological and technical analysis and mapping software system; the Tertiary Oil Recovery Information System (TORIS) database; and MS-Project, a project management software system.

  16. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  17. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    OpenAIRE

    Inna Pivovarova

    2016-01-01

    The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monito...

  18. A Solitary Wave-Based Sensor to Monitor the Setting of Fresh Concrete

    Directory of Open Access Journals (Sweden)

    Piervincenzo Rizzo

    2014-07-01

    Full Text Available We present a proof-of-principle study about the use of a sensor for the nondestructive monitoring of strength development in hydrating concrete. The nondestructive evaluation technique is based on the propagation of highly nonlinear solitary waves (HNSWs, which are non-dispersive mechanical waves that can form and travel in highly nonlinear systems, such as one-dimensional particle chains. A built-in transducer is adopted to excite and detect the HNSWs. The waves are partially reflected at the transducer/concrete interface and partially transmitted into the concrete. The time-of-flight and the amplitude of the waves reflected at the interface are measured and analyzed with respect to the hydration time, and correlated to the initial and final set times established by the penetration test (ASTM C 403. The results show that certain features of the HNSWs change as the concrete curing progresses indicating that it has the potential of being an efficient, cost-effective tool for monitoring strengths/stiffness development.

  19. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  20. Monitoring the CMS data acquisition system

    Science.gov (United States)

    Bauer, G.; Behrens, U.; Biery, K.; Branson, J.; Cano, E.; Cheung, H.; Ciganek, M.; Cittolin, S.; Coarasa, J. A.; Deldicque, C.; Dusinberre, E.; Erhan, S.; Fortes Rodrigues, F.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Gutleber, J.; Hatton, D.; Laurens, J. F.; Lopez Perez, J. A.; Meijers, F.; Meschi, E.; Meyer, A.; Mommsen, R.; Moser, R.; O'Dell, V.; Oh, A.; Orsini, L. B.; Patras, V.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Sakulin, H.; Sani, M.; Schieferdecker, P.; Schwick, C.; Shpakov, D.; Simon, S.; Sumorok, K.; Zanetti, M.

    2010-04-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of collections. An implementation following this scheme is deployed as the monitoring infrastructure of the CMS experiment at the Large Hadron Collider. All services in this distributed data acquisition system are providing standard web service interfaces via XML, SOAP and HTTP [15,22]. Continuing on this path we adopted WS-* standards implementing a monitoring system layered on top of the W3C standards stack. We designed a load-balanced publisher/subscriber system with the ability to include high-speed protocols [10,12] for efficient data transmission [11,13,14] and serving data in multiple data formats.

  1. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  2. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  3. Operations Monitoring Assistant System Design

    Science.gov (United States)

    1986-07-01

    subsections address these system , tesi ~n issues in tiirn. 3.1 OMA SYSTEM OVERVIEW Figure 3-1 presents the concept in Figure 2-1 in more detail, from an OMA...issues---a local agent cannot realistically Tell -he centralized planner everything about its current situation. and must instead ,t- cide what relevant

  4. ASHP national survey of pharmacy practice in hospital settings: monitoring and patient education--2012.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2013-05-01

    The results of the 2012 American Society of Health-System Pharmacists national survey of pharmacy practice in U.S. hospital settings are presented. A stratified random sample of pharmacy directors at 1413 general and children's medical-surgical hospitals were surveyed by mail. SDI Health supplied data on hospital characteristics; the survey sample was drawn from SDI's hospital database. In this national probability sample survey, the response rate was 34.0%. The rate of pharmacist monitoring of most patients (i.e., >75%) in hospitals has increased, from 20.3% in 2000 to 46.5% in 2012. Therapeutic drug monitoring programs are in place at most hospitals; at more than 80% of hospitals, pharmacists have the authority to order laboratory tests and adjust medication dosages. A safety culture assessment has been conducted at 72.4% of hospitals. Pharmacists routinely perform discharge counseling in 24.7% of hospitals. At most hospitals, nurses are primarily responsible for medication reconciliation, but 65.9% of pharmacy directors would like pharmacy to have this responsibility. Computerized prescriber order entry is now used in 54.4% of hospitals, with barcode-assisted medication administration used in 65.5% and smart pumps used in 77% of hospitals. The majority of hospitals have fully or partially implemented electronic health records. An increase in the use of remote pharmacist review of medication orders has reduced the percentage of hospitals where orders are not reviewed before a dose is administered to 32%. Pharmacists continue to improve medication use in U.S. hospitals through patient monitoring and education, safety initiatives, collaborative practices with other health care professionals, assisting in the adoption of technologies, and the provision of pharmacy services to outpatients.

  5. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  6. Heart monitoring systems--a review.

    Science.gov (United States)

    Jain, Puneet Kumar; Tiwari, Anil Kumar

    2014-11-01

    To diagnose health status of the heart, heart monitoring systems use heart signals produced during each cardiac cycle. Many types of signals are acquired to analyze heart functionality and hence several heart monitoring systems such as phonocardiography, electrocardiography, photoplethysmography and seismocardiography are used in practice. Recently, focus on the at-home monitoring of the heart is increasing for long term monitoring, which minimizes risks associated with the patients diagnosed with cardiovascular diseases. It leads to increasing research interest in portable systems having features such as signal transmission capability, unobtrusiveness, and low power consumption. In this paper we intend to provide a detailed review of recent advancements of such heart monitoring systems. We introduce the heart monitoring system in five modules: (1) body sensors, (2) signal conditioning, (3) analog to digital converter (ADC) and compression, (4) wireless transmission, and (5) analysis and classification. In each module, we provide a brief introduction about the function of the module, recent developments, and their limitation and challenges.

  7. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  8. Acoustic Flow Monitor System - User Manual

    Science.gov (United States)

    LaHusen, Richard

    2005-01-01

    INTRODUCTION The Acoustic Flow Monitor (AFM) is a portable system that was designed by the U.S. Geological Survey Cascades Volcano Observatory to detect and monitor debris flows associated with volcanoes. It has been successfully used internationally as part of real-time warning systems in valleys threatened by such flows (Brantley, 1990; Marcial and others, 1996; Lavigne and others, 2000). The AFM system has also been proven to be an effective tool for monitoring some non-volcanic debris flows. This manual is intended to serve as a basic guide for the installation, testing, and maintenance of AFM systems. An overview of how the system works, as well as instructions for installation and guidelines for testing, is included. Interpretation of data is not covered in this manual; rather, the user should refer to the references provided for published examples of AFM data.

  9. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  10. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  11. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, Gary L.; Meikrantz, David H.; Ely, Walter E.; Tuggle, Dale G.; Grafwallner, Ervin G.; Wickham, Keith L.; Maltrud, Herman R.; Baker, John D.

    1992-01-01

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter.

  12. Identification of electrical resistance of fresh state concrete for nondestructive setting process monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Woo [Dept. of Safety Engineering, Pukyong National University, Busan (Korea, Republic of)

    2015-12-15

    Concrete undergoes significant phase changes from liquid to solid states as hydration progresses. These phase changes are known as the setting process. A liquid state concrete is electrically conductive because of the presence of water and ions. However, since the conductive elements in the liquid state of concrete are consumed to produce non-conductive hydration products, the electrical conductivity of hydrating concrete decreases during the setting process. Therefore, the electrical properties of hydrating concrete can be used to monitor the setting process of concrete. In this study, a parameter identification method to estimate electrical parameters such as ohmic resistance of concrete is proposed. The effectiveness of the proposed method for monitoring the setting process of concrete is experimentally validated.

  13. Continuous monitoring of the zinc-phosphate acid-base cement setting reaction by proton nuclear magnetic relaxation

    Science.gov (United States)

    Apih, T.; Lebar, A.; Pawlig, O.; Trettin, R.

    2001-06-01

    Proton nuclear magnetic relaxation is a well-established technique for continuous and non destructive monitoring of hydration of conventional Portland building cements. Here, we demonstrate the feasibility of nuclear magnetic resonance (NMR) monitoring of the setting reaction of zinc-phosphate acid-base dental cements, which harden in minutes as compared to days, as in the case of Portland cements. We compare the setting of cement powder (mainly, zinc oxide) prepared with clinically used aluminum-modified orthophosphoric acid solution with the setting of a model system where cement powder is mixed with pure orthophosphoric acid solution. In contrast to previously published NMR studies of setting Portland cements, where a decrease of spin-lattice relaxation time is attributed to enhanced relaxation at the growing internal surface, spin-lattice relaxation time T1 increases during the set of clinically used zinc-phosphate cement. Comparison of these results with a detailed study of diffusion, viscosity, and magnetic-field dispersion of T1 in pure and aluminum-modified orthophosphoric acid demonstrates that the increase of T1 in the setting cement is connected with the increase of molecular mobility in the residual phosphoric acid solution. Although not taken into account so far, such effects may also significantly influence the relaxation times in setting Portland cements, particularly when admixtures with an effect on water viscosity are used.

  14. Valve-"Health"-Monitoring System

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  15. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. Here, I present the detector...

  16. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly Marie

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to supress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will descri...

  17. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  18. Diabetes Monitoring System Using Mobile Computing Technologies

    Directory of Open Access Journals (Sweden)

    Mashael Saud Bin-Sabbar

    2013-03-01

    Full Text Available Diabetes is a chronic disease that needs to regularly be monitored to keep the blood sugar levels within normal ranges. This monitoring depends on the diabetic treatment plan that is periodically reviewed by the endocrinologist. The frequent visit to the main hospital seems to be tiring and time consuming for both endocrinologist and diabetes patients. The patient may have to travel to the main city, paying a ticket and reserving a place to stay. Those expenses can be reduced by remotely monitoring the diabetes patients with the help of mobile devices. In this paper, we introduce our implementation of an integrated monitoring tool for the diabetes patients. The designed system provides a daily monitoring and monthly services. The daily monitoring includes recording the result of daily analysis and activates to be transmitted from a patient’s mobile device to a central database. The monthly services require the patient to visit a nearby care center in the patient home town to do the medical examination and checkups. The result of this visit entered into the system and then synchronized with the central database. Finally, the endocrinologist can remotely monitor the patient record and adjust the treatment plan and the insulin doses if need.

  19. Amplified OTDR systems for multipoint corrosion monitoring.

    Science.gov (United States)

    Nascimento, Jehan F; Silva, Marcionilo J; Coêlho, Isnaldo J S; Cipriano, Eliel; Martins-Filho, Joaquim F

    2012-01-01

    We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR) technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations.

  20. Amplified OTDR Systems for Multipoint Corrosion Monitoring

    Directory of Open Access Journals (Sweden)

    Joaquim F. Martins-Filho

    2012-03-01

    Full Text Available We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations.

  1. Well Monitoring System For EGS

    Energy Technology Data Exchange (ETDEWEB)

    Normann, Randy [Perma Works LLC, Pattonville, TX (United States); Glowka, Dave [Perma Works LLC, Pattonville, TX (United States); Normann, Charles [Perma Works LLC, Pattonville, TX (United States); Parker, James [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Josip [Electrochemical Systems Inc, Knoxville, TN (United States); Dustan, Don [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Mario [Electrochemical Systems Inc, Knoxville, TN (United States); Sariri, Kouros [Frequency Management Int. Inc., Huntington Beach, CA (United States); Beal, Craig [MajiQ Technologies Inc., Somerville, MA (United States)

    2017-02-26

    This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

  2. The Combat-Wireless Health Monitoring System

    Science.gov (United States)

    2009-12-01

    not monitor concussions sustained by casualties. This article proposes the develop- ment of a new C-WHMS as an alterna- tive to the WPSM. The C-WHMS...monitoring system embedded within the Advanced Combat Helmet (ACH), which measures concussions sustained during the execution of combat operations. The...component of the C-WHMS, as embedded in the ACH. Concussions sus- tained by soldiers are a major concern of military leadership. The goal is to quickly

  3. An automated neutron monitor maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-09-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector`s functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  4. Research and Construction the Net Monitor System

    OpenAIRE

    Ruining Huang; Lei Li; Yunjiang Lou

    2012-01-01

    A Net Monitor system is presented in this paper. The system is based on STMicroelectronics board FLTK3D, which provides hardware platform for TV functions--3D film, IPTV, 3D game, cable television and so on. The whole system includes the Linux Operating System (OS), embedded web browser, Media player, clouding applications, video conference and 3D game. It utilizes the reference model of the CLFS (Cross Linux From Scratches) principle to construct the embedded Linux OS. Cloud applications are...

  5. A Research on Distributed Emergency Monitoring System

    Institute of Scientific and Technical Information of China (English)

    WANG; Kai; LI; Hang; YANG; Hong-wei; LIU; Yang; ZHANG; Liang; CHEN; Ling; XIONG; Wen-jun

    2013-01-01

    1 Introduction The distributed emergency monitoring system(DEMS),which has distributed measurement,centralized information processing features,including integrated radiation detectors,wireless transmission evaluation and presentation software module.The system uses a GM counter and NaI(Tl)spectrometer to quickly get the information of the radiation field,and transmits the information to the on-site information

  6. Monitoring and Technical Assistance Review System Notebook

    Science.gov (United States)

    Administration for Children & Families, 2008

    2008-01-01

    This notebook provides guidance on the Monitoring and Technical Assistance Review System (MTARS). The manual is intended for use by Administration on Developmental Disabilities (ADD) staff who manage MTARS and by MTARS reviewers who conduct site visit activities. The notebook is also designed to help Councils, Protection and Advocacy Systems, and…

  7. Psychometric aspects of pupil monitoring systems

    NARCIS (Netherlands)

    Glas, Cees A.W.; Geerlings, Hanneke

    2009-01-01

    Pupil monitoring systems support the teacher in tailoring teaching to the individual level of a student and in comparing the progress and results of teaching with national standards. The systems are based on the availability of an item bank calibrated using item response theory. The assessment of th

  8. Active system monitoring applied on wind turbines

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad; Parbo, Henrik

    2009-01-01

    A concept for active system monitoring (ASM) applied on wind turbines is presented in this paper. The concept is based on an injection of a small periodic auxiliary signal in the system. An investigation of the signature from the auxiliary input in residual (error) signals can then be applied...

  9. Priority-setting in health systems

    DEFF Research Database (Denmark)

    Byskov, Jens

    2013-01-01

    , and surveys in nearby villages have shown a high prevalence of intestinal helminthiasis and schistosomiasis. The HIV prevalence in similar rural settings is about 10% in her age group. She has been losing weight over the last months and now her one-year-old child feels hot and is not eating well. She has...

  10. System Reliability Analysis of Redundant Condition Monitoring Systems

    Institute of Scientific and Technical Information of China (English)

    YI Pengxing; HU Youming; YANG Shuzi; WU Bo; CUI Feng

    2006-01-01

    The development and application of new reliability models and methods are presented to analyze the system reliability of complex condition monitoring systems. The methods include a method analyzing failure modes of a type of redundant condition monitoring systems (RCMS) by invoking failure tree model, Markov modeling techniques for analyzing system reliability of RCMS, and methods for estimating Markov model parameters. Furthermore, a computing case is investigated and many conclusions upon this case are summarized. Results show that the method proposed here is practical and valuable for designing condition monitoring systems and their maintenance.

  11. Fault-Tolerant Onboard Monitoring and Decision Support Systems

    DEFF Research Database (Denmark)

    Lajic, Zoran

    a crude and simple estimation of the actual sea state (Hs and Tz), information about the longitudinal hull girder loading, seakeeping performance of the ship, and decision support on how to operate the ship within acceptable limits. The system is able to identify critical forthcoming events and to give...... advice regarding speed and course changes to decrease the wave-induced loads. The SeaSense system is based on the combined use of a mathematical model and measurements from a set of sensors. The overall dependability of a shipboard monitoring and decision support system such as the SeaSense system can......The purpose of this research project is to improve current onboard decision support systems. Special focus is on the onboard prediction of the instantaneous sea state. In this project a new approach to increasing the overall reliability of a monitoring and decision support system has been...

  12. Remote container monitoring and surveillance systems

    Energy Technology Data Exchange (ETDEWEB)

    Resnik, W.M.; Kadner, S.P. [Aquila Technologies Group, Inc., Albuquerque, NM (United States)

    1995-12-31

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila`s Gemini All-Digital Surveillance System and on Aquila`s AssetLAN{trademark} asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN{trademark} technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed.

  13. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  14. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  15. Statistical process control methods for expert system performance monitoring.

    Science.gov (United States)

    Kahn, M G; Bailey, T C; Steib, S A; Fraser, V J; Dunagan, W C

    1996-01-01

    The literature on the performance evaluation of medical expert system is extensive, yet most of the techniques used in the early stages of system development are inappropriate for deployed expert systems. Because extensive clinical and informatics expertise and resources are required to perform evaluations, efficient yet effective methods of monitoring performance during the long-term maintenance phase of the expert system life cycle must be devised. Statistical process control techniques provide a well-established methodology that can be used to define policies and procedures for continuous, concurrent performance evaluation. Although the field of statistical process control has been developed for monitoring industrial processes, its tools, techniques, and theory are easily transferred to the evaluation of expert systems. Statistical process tools provide convenient visual methods and heuristic guidelines for detecting meaningful changes in expert system performance. The underlying statistical theory provides estimates of the detection capabilities of alternative evaluation strategies. This paper describes a set of statistical process control tools that can be used to monitor the performance of a number of deployed medical expert systems. It describes how p-charts are used in practice to monitor the GermWatcher expert system. The case volume and error rate of GermWatcher are then used to demonstrate how different inspection strategies would perform.

  16. Monitoring SLAC High Performance UNIX Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lettsome, Annette K.; /Bethune-Cookman Coll. /SLAC

    2005-12-15

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface.

  17. Smart Sensor Network System For Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Javed Ali Baloch

    2012-07-01

    Full Text Available SSN (Smart Sensor Network systems could be used to monitor buildings with modern infrastructure, plant sites with chemical pollution, horticulture, natural habitat, wastewater management and modern transport system. To sense attributes of phenomena and make decisions on the basis of the sensed value is the primary goal of such systems. In this paper a Smart Spatially aware sensor system is presented. A smart system, which could continuously monitor the network to observe the functionality and trigger, alerts to the base station if a change in the system occurs and provide feedback periodically, on demand or even continuously depending on the nature of the application. The results of the simulation trials presented in this paper exhibit the performance of a Smart Spatially Aware Sensor Networks.

  18. Continuous Glucose Monitoring Systems: A Review

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2013-10-01

    Full Text Available There have been continuous advances in the field of glucose monitoring during the last four decades, which have led to the development of highly evolved blood glucose meters, non-invasive glucose monitoring (NGM devices and continuous glucose monitoring systems (CGMS. Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complications. CGMS have led to tremendous improvements in diabetic management, as shown by the significant lowering of glycated hemoglobin (HbA1c in adults with type I diabetes. Most of the CGMS have been minimally-invasive, although the more recent ones are based on NGM techniques. This manuscript reviews the advances in CGMS for diabetes management along with the future prospects and the challenges involved.

  19. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  20. Developments in CD4 and viral load monitoring in resource-limited settings.

    Science.gov (United States)

    Rowley, Christopher F

    2014-02-01

    CD4 counts and human immunodeficiency virus (HIV) load testing are essential components of HIV care, and making these tests available in resource-limited settings is critical to the roll-out of HIV treatment globally. Until recently, the evidence supporting the importance of laboratory monitoring in resource-limited settings was lacking, but there is now a consensus emerging that testing should become routine to ensure the longevity of treatment programs. Low-cost, point-of-care testing offers the potential to fill this role as it potentially improves all aspects of HIV care, ranging from the diagnosis and staging of HIV infection in both infants and adults to monitoring for treatment failure once antiretroviral therapy has been initiated. It is imperative for low-cost solutions to become a reality, but it is equally imperative that close scrutiny be given to each new device that hits the market to ensure they perform optimally in all settings.

  1. Priority-setting in health systems

    DEFF Research Database (Denmark)

    Byskov, Jens

    2013-01-01

    tried herbal remedies for both of them for a week but without effect. The family permits her to travel with her child quite some distance to a fairly run down health centre ---- (Cont. with her meeting services, but going home unserved) WHAT ARE HEALTH SYSTEMS AND HEALTH SYSTEMS RESEARCH? Health systems...... and constraints. This effectively leaves policy-makers.without scientifically sound ideas of what they can and should actually strengthen within ever limited resources. Within such unmapped and misunderstood systems, interventions – even the very simplest – often fail to achieve their goals and no recommeded...

  2. Design of Wind Turbine Vibration Monitoring System

    Directory of Open Access Journals (Sweden)

    Shoubin Wang

    2013-04-01

    Full Text Available In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed. In this paper, it analyses the enlargement of all the parts of the structure and the working mechanism, the research method of wind turbine operation vibration is introduced, with the focus being the use of the sensor principle. Finally the hardware design and software of this system is introduced and the main function of this system is described, which realizes condition monitoring of the work state of wind turbines.

  3. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  4. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  5. Multiobjective Design of Wearable Sensor Systems for Electrocardiogram Monitoring

    Directory of Open Access Journals (Sweden)

    F. J. Martinez-Tabares

    2016-01-01

    Full Text Available Wearable sensor systems will soon become part of the available medical tools for remote and long term physiological monitoring. However, the set of variables involved in the performance of these systems are usually antagonistic, and therefore the design of usable wearable systems in real clinical applications entails a number of challenges that have to be addressed first. This paper describes a method to optimise the design of these systems for the specific application of cardiac monitoring. The method proposed is based on the selection of a subset of 5 design variables, sensor contact, location, and rotation, signal correlation, and patient comfort, and 2 objective functions, functionality and wearability. These variables are optimised using linear and nonlinear models to maximise those objective functions simultaneously. The methodology described and the results achieved demonstrate that it is possible to find an optimal solution and therefore overcome most of the design barriers that prevent wearable sensor systems from being used in normal clinical practice.

  6. Run Control and Monitor System for the CMS Experiment

    CERN Document Server

    Bellato, M; Brigljevic, V; Bruno, G; Cano, E; Cittolin, Sergio; Csilling, Akos; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutleber, J; Jacobs, C; Kozlovszky, Miklos; Larsen, H; Magrans de Abril, Ildefons; Maron, G; Meijers, F; Meschi, E; Murray, S; Oh, A; Orsini, L; Pollet, L; Rácz, A; Rorato, G; Samyn, D; Scharff-Hansen, P; Schwick, C; Sphicas, Paris; Toniolo, N; Ventura, Sandro; Zangrando, L

    2003-01-01

    The Run Control and Monitor System (RCMS) of the CMS experiment is the set of hardware and software components responsible for controlling and monitoring the experiment during data-taking. It provides users with a "virtual counting room", enabling them to operate the experiment and to monitor detector status and data quality from any point in the world. This paper describes the architecture of the RCMS with particular emphasis on its scalability through a distributed collection of nodes arranged in a tree-based hierarchy. The current implementation of the architecture in a prototype RCMS used in test beam setups, detector validations and DAQ demonstrators is documented. A discussion of the key technologies used, including Web Services, and the results of tests performed with a 128-node system are presented.

  7. Wireless remote monitoring system for sleep apnea

    Science.gov (United States)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2011-04-01

    Sleep plays the important role of rejuvenating the body, especially the central nervous system. However, more than thirty million people suffer from sleep disorders and sleep deprivation. That can cause serious health consequences by increasing the risk of hypertension, diabetes, heart attack and so on. Apart from the physical health risk, sleep disorders can lead to social problems when sleep disorders are not diagnosed and treated. Currently, sleep disorders are diagnosed through sleep study in a sleep laboratory overnight. This involves large expenses in addition to the inconvenience of overnight hospitalization and disruption of daily life activities. Although some systems provide home based diagnosis, most of systems record the sleep data in a memory card, the patient has to face the inconvenience of sending the memory card to a doctor for diagnosis. To solve the problem, we propose a wireless sensor system for sleep apnea, which enables remote monitoring while the patient is at home. The system has 5 channels to measure ECG, Nasal airflow, body position, abdominal/chest efforts and oxygen saturation. A wireless transmitter unit transmits signals with Zigbee and a receiver unit which has two RF modules, Zigbee and Wi-Fi, receives signals from the transmitter unit and retransmits signals to the remote monitoring system with Zigbee and Wi-Fi, respectively. By using both Zigbee and Wi-Fi, the wireless sensor system can achieve a low power consumption and wide range coverage. The system's features are presented, as well as continuous monitoring results of vital signals.

  8. THE FEATURES OF AIRCRAFT FUNCTIONAL SYSTEMS PERFORMANCE MONITORING

    Directory of Open Access Journals (Sweden)

    Stanislav Alexandrovich Krotov

    2017-01-01

    Full Text Available The key steps of aircraft essential parameters and events monitoring during its operation are considered in the arti- cle. Conditions for specific risk monitoring are also presented.The notion of fail-safe feature of aircraft functional systems is analysed, and the necessity of continuous process of safety flight level estimate is shown. The method of quantitative assessment of key events and risks probabilities with the use of modern software is proposed. This method contains 5 basic stages: The monitoring parameters setting - this stage is initial and begins with the consideration of organization safety cul- ture, the main purposes and problems determination, the basic parameters and characteristics forming which are to be monitored. The event monitoring in operation - on this stage continuous process of key events searching and monitoring which are a thing of importance within the framework of the established problems takes place. This process is closely relat- ed to parameters monitoring set on the first stage. The event and risk estimate - this stage begins directly after the event has been discovered. The estimate pro- cess is as long as it is required to identify the event gravity. It also contains the preliminary risk estimate for using in priori- tization of initial expanded estimate and in the working out of plan for activities realization. The working out of plan for activities - on this stage correction data is determined that will make changes to aero- technics working out, operation, maintenance and to staff training directly in linkage to the problem event identified earlier. The activity carrying-out - the realization of actions according to the activity plan. This stage concludes priori- tization, planning and problem carrying-out. The dependence set between the probability of failure situations and the degree of their danger is shown. The key factors which are subject to be estimated while aircraft operating and which aim with

  9. The impacts of a pharmacist-managed outpatient clinic and chemotherapy-directed electronic order sets for monitoring oral chemotherapy.

    Science.gov (United States)

    Battis, Brandon; Clifford, Linda; Huq, Mostaqul; Pejoro, Edrick; Mambourg, Scott

    2016-10-12

    Patients treated with oral chemotherapy appear to have less contact with the treating providers. As a result, safety, adherence, medication therapy monitoring, and timely follow-up may be compromised. The trend of treating cancer with oral chemotherapy agents is on the rise. However, standard clinical guidance is still lacking for prescribing, monitoring, patient education, and follow-up of patients on oral chemotherapy across the healthcare settings. The purpose of this project is to establish an oral chemotherapy monitoring clinic, to create drug and lab specific provider order sets for prescribing and lab monitoring, and ultimately to ensure safe and effective treatment of the veterans we serve. A collaborative agreement was reached among oncology pharmacists, a pharmacy resident, two oncologists, and a physician assistant to establish a pharmacist-managed oral chemotherapy monitoring clinic at the VA Sierra Nevada Healthcare System. Drug-specific electronic order sets for prescribing and lab monitoring were created for initiating new drug therapy and prescription renewal. The order sets were created to be provider-centric, minimizing clicks needed to order necessary medications and lab monitoring. A standard progress note template was developed for documenting interventions made by the clinic. Patients new to an oral chemotherapy regimen were first counseled by an oncology pharmacist. The patients were then enrolled into the oral chemotherapy monitoring clinic for subsequent follow up and pharmacist interventions. Further, patients lacking monitoring or missing provider appointments were captured through a Clinical Dashboard developed by the US Department of Veterans Affairs (VA) Regional Office (VISN21) using SQL Server Reporting Services. Between September 2014 and April 2015, a total of 68 patients on different oral chemotherapy agents were enrolled into the clinic. Out of the 68 patients enrolled into the oral chemotherapy monitoring clinic, 31 patients (45

  10. Design of multi-function Hanford tank corrosion monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    EDGEMON, G.L.

    1999-04-01

    A multi-fiction corrosion monitoring system has been designed for installation into DST 241-AN-105 at the Hanford Site in fiscal year 1999. The 241-AN-105 system is the third-generation corrosion monitoring system described by TTP RLO-8-WT-21. Improvements and upgrades from the second-generation system (installed in 241-AN-102) that have been incorporated into the third-generation system include: Gasket seating surfaces utilize O-rings instead of a washer type gasket for improved seal; Probe design contains an equally spaced array of 22 thermocouples; Probe design contains an adjustable verification thermocouple; Probe design contains three ports for pressure/gas sampling; Probe design contains one set of strain gauges to monitor probe flexure if flexure occurs; Probe utilizes an adjustable collar to allow depth adjustment of probe during installation; System is capable of periodically conducting LPR scans; System is housed in a climate controlled enclosure adjacent to the riser containing the probe; System uses wireless Ethernet links to send data to Hanford Local Area Network; System uses commercial remote access software to allow remote command and control; and Above ground wiring uses driven shields to reduce external electrostatic noise in the data. These new design features have transformed what was primarily a second-generation corrosion monitoring system into a multi-function tank monitoring system that adds a great deal of functionality to the probe, provides for a better understanding of the relationship between corrosion and other tank operating parameters, and optimizes the use of the riser that houses the probe in the tank.

  11. Artificial Neural Network and Rough Set for HV Bushings Condition Monitoring

    CERN Document Server

    Mpanza, LJ

    2011-01-01

    Most transformer failures are attributed to bushings failures. Hence it is necessary to monitor the condition of bushings. In this paper three methods are developed to monitor the condition of oil filled bushing. Multi-layer perceptron (MLP), Radial basis function (RBF) and Rough Set (RS) models are developed and combined through majority voting to form a committee. The MLP performs better that the RBF and the RS is terms of classification accuracy. The RBF is the fasted to train. The committee performs better than the individual models. The diversity of models is measured to evaluate their similarity when used in the committee.

  12. Harassment Monitoring System Using Android Smartphone

    Directory of Open Access Journals (Sweden)

    Shivu Gururaj, Dr. Raj Shekhar M Pati

    2013-09-01

    Full Text Available In this paper we propose a system for monitoring harassment. It is essentially software installed on phone which informs the security (e.g. police and dear ones (e.g. parents with location details and seeking for help message. It posts the same details on server to notify public for help.

  13. DIADEM: a system for collaborative environmental monitoring

    NARCIS (Netherlands)

    Winterboer, A.; Martens, M.A.; Pavlin, G.; Groen, F.C.A.; Evers, V.

    2011-01-01

    Environmental monitoring and emergency response projects in urban-industrial areas increasingly rely on efficient collaboration between experts in control rooms and at incident locations, and citizens who live or work in the area. In the video accompanying this abstract we present a system that uses

  14. A hand-hygiene behaviour monitoring system

    NARCIS (Netherlands)

    Van Schie, M.; Wiesman, R.F.F.

    2008-01-01

    The invention relates to a hand-hygiene behaviour monitoring system, comprising: means for detecting the occurrence of an event specified in a hand-hygiene rule, wherein the event involves a person; means for updating behaviour data that is related to acts according to the hand-hygiene rule, wherein

  15. Energy monitoring and control Systems - which one

    Energy Technology Data Exchange (ETDEWEB)

    Agase, H.D.

    1980-01-01

    Considering the high cost and general limitations of energy supplies, there is no better source of energy than simple conservation. It is the cheapest, the safest and the most productive alternative available today. This overview of Energy Monitoring and Control System types, and what to consider in their selection, will relate to conservation and significant dollar savings potential to the user.

  16. Mobile Patient Monitoring: The Mobihealth System

    NARCIS (Netherlands)

    Halteren, van Aart; Bults, Richard; Wac, Katarzyna; Konstantas, Dimitri; Widya, Ing; Dokovski, Nikolay; Koprinkov, George; Jones, Val; Herzog, Rainer

    2004-01-01

    The forthcoming wide availability of high bandwidth public wireless networks will give rise to new mobile healthcare services. To this end, the MobiHealth project has developed and trialed a highly customisable vital signs monitoring system based on a body area network (BAN) and a mobile-health (m-h

  17. Locomotive monitoring system using wireless sensor networks

    CSIR Research Space (South Africa)

    Croucamp, PL

    2014-07-01

    Full Text Available Theft of cables used for powering a locomotive not only stops the train from functioning but also paralyzes the signalling and monitoring system. This means that information on certain locomotive's cannot be passed onto other locomotives which may...

  18. 21 CFR 876.1725 - Gastrointestinal motility monitoring system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastrointestinal motility monitoring system. 876... Gastrointestinal motility monitoring system. (a) Identification. A gastrointestinal motility monitoring system is a... esophageal motility monitor and tube, the gastrointestinal motility (electrical) system, and...

  19. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons......A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... will be tested. Laboratory studies as well as on-line measurements in district heating systems using probes in a specially designed sidestream unit are included in the practical part of the project....

  20. Topological bifurcations of minimal invariant sets for set-valued dynamical systems

    CERN Document Server

    Lamb, Jeroen S W; Rodrigues, Christian S

    2011-01-01

    We discuss the dependence of set-valued dynamical systems on parameters. Under mild assumptions which are often satisfied for random dynamical systems with bounded noise and control systems, we establish the fact that topological bifurcations of minimal invariant sets are discontinuous with respect to the Hausdorff metric, taking the form of lower semi-continuous explosions and instantaneous appearances. We also characterise these transitions by properties of Morse-like decompositions.

  1. Condition Indicators for Gearbox Condition Monitoring Systems

    OpenAIRE

    P. Večeř; M. Kreidl; R. Šmíd

    2005-01-01

    Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs) are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical ge...

  2. Condition Indicators for Gearbox Condition Monitoring Systems

    Directory of Open Access Journals (Sweden)

    P. Večeř

    2005-01-01

    Full Text Available Condition monitoring systems for manual transmissions based on vibration diagnostics are widely applied in industry. The systems deal with various condition indicators, most of which are focused on a specific type of gearbox fault. Frequently used condition indicators (CIs are described in this paper. The ability of a selected condition indicator to describe the degree of gearing wear was tested using vibration signals acquired during durability testing of manual transmission with helical gears. 

  3. IMPLEMENTATION PAPER ON REAL ESTATE MONITORING SYSTEM

    OpenAIRE

    Sunidhi Kabra*, Vivek Mishra, Kshitiz Kesharwani, Shivaanshu Nagarkar

    2016-01-01

    With the enhancements in the Internet and computer technology, we are now able to do most of our work automatically, for example, e-wallet, online payments, etc. As a whole, Internet has made our lives simpler. Making use of modern day Internet and computer technologies, we have come up with an online system useful in the field of construction. Our concept, Real Estate Monitoring System, enables any individual constructor to automate the manual logs maintained at a construction site. By this ...

  4. Advanced Risk Management and Monitoring System, ARMMS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kil Yoo; Han, Sang Hoon; Lim, Ho Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Many risk informed regulation and applications (RIR and A) are approved and used for the nuclear power plants(NPPs), and more RIR and A will be actively applied in Korea. Also, since Korean NPPs are recently exported to other country such as UAE, RIR and A would be applied to the exported NPPs. Thus, a tool which will help the user apply RIR and A is required. KAERI is being developing a tool, called ARMMS (Advanced Risk Management and Monitoring System), for this purpose. The design plan of ARMMS was introduced in the Ref, and in this paper, the actual implementation of ARMMS is introduced, and the performance monitoring module is introduced

  5. System and method for statistically monitoring and analyzing sensed conditions

    Science.gov (United States)

    Pebay, Philippe P.; Brandt, James M. , Gentile; Ann C. , Marzouk; Youssef M. , Hale; Darrian J. , Thompson; David C.

    2010-07-13

    A system and method of monitoring and analyzing a plurality of attributes for an alarm condition is disclosed. The attributes are processed and/or unprocessed values of sensed conditions of a collection of a statistically significant number of statistically similar components subjected to varying environmental conditions. The attribute values are used to compute the normal behaviors of some of the attributes and also used to infer parameters of a set of models. Relative probabilities of some attribute values are then computed and used along with the set of models to determine whether an alarm condition is met. The alarm conditions are used to prevent or reduce the impact of impending failure.

  6. The effects of self-monitoring and supervisor feedback on staff performance in a residential setting.

    Science.gov (United States)

    Richman, G S; Riordan, M R; Reiss, M L; Pyles, D A; Bailey, J S

    1988-01-01

    We evaluated the effects of a self-monitoring procedure to increase staff on-task behavior and adherence to scheduled activities. Self-monitoring involved the use of activity cards that staff members completed and carried with them to assist in determining the activities for which they were responsible at any given time. Increases in both on-schedule and on-task behavior resulted. Supervisor feedback was subsequently added because some staff members did not maintain consistently high levels of performance. Generalization data indicated that staff members implemented the procedure during evening hours without specific programming. The advantages and limitations of using a self-monitoring procedure for improving performance of staff members in residential settings are discussed.

  7. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  8. Replaceable Sensor System for Bioreactor Monitoring

    Science.gov (United States)

    Mayo, Mike; Savoy, Steve; Bruno, John

    2006-01-01

    A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

  9. Dynamic Experimental Research on Setting Signal Transmission of Induction Setting System in Muzzle

    Institute of Scientific and Technical Information of China (English)

    HUANG Xue-gong

    2009-01-01

    Muzzle induction setting is a high speed dynamic process. Based on analyzing the process of the projectile flying through an induction setting field, an experimental method is studied to test the effect of high speed plasma gas and high speed projectile on the induction setting system. Three tests are designed. The real-time coupling curves of induction setting signal are tested by coupling a test coil. The experimental results indicate that the electromagnetic field formed by high speed plasma gas can influence the signal transmission of induction setting system, and the influence can be reduced by opening some vents on muzzle; the high speed projectile changed the distributing characteristics of electromagnetic field in the induction setting field to reduce the amplitude of induction coupling signal.

  10. Dosimetric properties of a scanned beam microtron at low monitor unit settings: importance for conformal therapy.

    Science.gov (United States)

    Humm, J L; Larsson, A; Lief, E P

    1996-03-01

    The dosimetric stability, linearity, dose rate dependence, and flatness of both photon and electron beams have been evaluated for a racetrack microtron at low monitor unit settings. For photons, the variation in dosimetric output about the mean is 3% at 20 cm, even at only 3 MU, in contrast with other scanned beam accelerators. Broad electron beams on the microtron are created by the superposition of the elementary beam pulses either directly from the scan magnets, or after their broadening through a scattering foil. The dosimetric instability both with and without the foil was less than 0.6% for both the 25- and 50-MeV electrons. Dose nonlinearity was microtron exhibits dosimetric properties which fulfill the recommendations of Task Groups 21 and 25. Based on the stability of the scanned beam at low monitor unit settings, the microtron can be used for 3-D conformal therapy with both photons and electrons.

  11. Embedded programmable blood pressure monitoring system

    Science.gov (United States)

    Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk

    2010-02-01

    A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.

  12. Estimating the globally attractive set and positively invariant set of a unified chaotic system

    Institute of Scientific and Technical Information of China (English)

    SHU Yong-lu; ZHANG Yong-hao

    2008-01-01

    By constructing two suitable generalized Lyapunov functions, we derived a generalized ellipsoidal estimate of the globally attractive set and positively invariant set of the unified chaotic system with the parameters a=1/29 and 1/29set for the Lorenz system and a unified chaotic system, Journal of Mathematical Analysis and Applications, 2006, 323(2): 844-853]. The theoretical results obtained in this paper will find wide application in chaos control and synchronization.

  13. Building a Data Set over 12 Globally Distributed Sites to Support the Development of Agriculture Monitoring Applications with Sentinel-2

    Directory of Open Access Journals (Sweden)

    Sophie Bontemps

    2015-12-01

    Full Text Available Developing better agricultural monitoring capabilities based on Earth Observation data is critical for strengthening food production information and market transparency. The Sentinel-2 mission has the optimal capacity for regional to global agriculture monitoring in terms of resolution (10–20 meter, revisit frequency (five days and coverage (global. In this context, the European Space Agency launched in 2014 the “Sentinel­2 for Agriculture” project, which aims to prepare the exploitation of Sentinel-2 data for agriculture monitoring through the development of open source processing chains for relevant products. The project generated an unprecedented data set, made of “Sentinel-2 like” time series and in situ data acquired in 2013 over 12 globally distributed sites. Earth Observation time series were mostly built on the SPOT4 (Take 5 data set, which was specifically designed to simulate Sentinel-2. They also included Landsat 8 and RapidEye imagery as complementary data sources. Images were pre-processed to Level 2A and the quality of the resulting time series was assessed. In situ data about cropland, crop type and biophysical variables were shared by site managers, most of them belonging to the “Joint Experiment for Crop Assessment and Monitoring” network. This data set allowed testing and comparing across sites the methodologies that will be at the core of the future “Sentinel­2 for Agriculture” system.

  14. A Resilient Condition Assessment Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Humberto Garcia; Wen-Chiao Lin; Semyon M. Meerkov

    2012-08-01

    An architecture and supporting methods are presented for the implementation of a resilient condition assessment monitoring system that can adaptively accommodate both cyber and physical anomalies to a monitored system under observation. In particular, the architecture includes three layers: information, assessment, and sensor selection. The information layer estimates probability distributions of process variables based on sensor measurements and assessments of the quality of sensor data. Based on these estimates, the assessment layer then employs probabilistic reasoning methods to assess the plant health. The sensor selection layer selects sensors so that assessments of the plant condition can be made within desired time periods. Resilient features of the developed system are then illustrated by simulations of a simplified power plant model, where a large portion of the sensors are under attack.

  15. Methods, apparatus, and systems for monitoring transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Polk, Robert E; Svoboda, John M.; West, Phillip B.; Heath, Gail L.; Scott, Clark L.

    2016-07-19

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  16. System for monitoring microclimate conditions in greenhouse

    Directory of Open Access Journals (Sweden)

    Marković Dušan B.

    2014-01-01

    Full Text Available Monitoring microclimate parameters in different kind of environments has significant contribution to many areas of human activity and production processes. One of them is vegetable production in greenhouses where measurement of its microclimate parameters may influence the decision on taking appropriate action and protect crops. It is also important to preserve optimal condition in greenhouses to facilitate the process of transpiration, plant mineral nutrition and prevent of a variety physiological damage caused by a deficit of some specific nutrients. Systems for monitoring have wide application in the last years thanks to development of modern computer technology. In this paper model of the monitoring system based on smart transducer concept was introduced. Within the system components are based on MSP430 ultra low power micro controllers. They are using wireless communication to exchange data within the system that was structured according to smart transducer concept. User applications from the network could access to system interface using HTTP protocol where web server could be running on the computer or it could be an embedded web server running on micro controller based device.

  17. The environmental radiation monitoring system in Spain

    Directory of Open Access Journals (Sweden)

    Rosario Salas Collantes

    2010-12-01

    Full Text Available The system of environmental radiation monitoring established in Spain is composed of several networks with different objectives, a monitoring network in the vicinity of the facilities and several national networks financed and managed by public agencies. The operators of the facilities are responsible for the conduct of its Environmental Radiological Surveillance Program as directed by the CSN. Moreover, the Directorate General of Civil Defense and Emergencies has a Radioactivity Warning Network (RAR consisting of over 900 automatic stations measuring dose rate distributed nationwide. The Environmental Radioactivity Monitoring Network (Revira, managed by the CSN, is a nationwide network, consists of a Network of Sampling Stations (REM and a Network of Automatic Stations for continuous monitoring (REA. The autonomous communities of Valencia, Catalonia, Extremadura and the Basque Country have their own automated networks similar to that of the CSN. Revira provides information on the radioactivity in the air, soil, water (drinking, inland and sea and of food. The sampling and analysis programs are tailored to radiological recommendations laid down in the European Union Commission. The REM has the collaboration of laboratories in universities and the Centre for Energy, Environmental and Technological Research (CIEMAT for execution. The monitoring of inland and coastal waters is undertaken by the Centre for Studies and Experimentation of Public Works, Ministry of Public Works (CEDEX.

  18. 40 CFR 265.91 - Ground-water monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  19. New data visualization of the LHC Era Monitoring (Lemon) system

    Science.gov (United States)

    Ivan, Fedorko; Veronique, Lefebure; Daniel, Lenkes; Omar, Pera Mira

    2012-12-01

    In the last few years, new requirements have been received for visualization of monitoring data: advanced graphics, flexibility in configuration and decoupling of the presentation layer from the monitoring repository. Lemonweb is the data visualization component of the LHC Era Monitoring (Lemon) system. Lemonweb consists of two subcomponents: a data collector and a web visualization interface. The data collector is a daemon, implemented in Python, responsible for data gathering from the central monitoring repository and storing into time series data structures. Data is stored on disk in Round Robin Database (RRD) files: one file per monitored entity, with set of entity related metrics. Entities may be grouped into a hierarchical structure, called “clusters” and supporting mathematical operations over entities and clusters (e.g. cluster A + cluster B /clusters C - entity XY). Using the configuration information, a cluster definition is evaluated in the collector engine and, at runtime, a sequence of data selects is built, to optimize access to the central monitoring repository. In this article, an overview of the design and architecture as well as highlights of some implemented features will be presented.

  20. Launch Pad 39 Hail Monitor Array System

    Science.gov (United States)

    2008-01-01

    Weather conditions at Kennedy Space Center are extremely dynamic, and they greatly affect the safety of the Space Shuttles sitting on the launch pads. For example, on May 13, 1999, the foam on the External Tank (ET) of STS-96 was significantly damaged by hail at the launch pad, requiring rollback to the Vehicle Assembly Building. The loss of ET foam on STS-114 in 2005 intensified interest in monitoring and measuring damage to ET foam, especially from hail. But hail can be difficult to detect and monitor because it is often localized and obscured by heavy rain. Furthermore, the hot Florida climate usually melts the hail even before the rainfall subsides. In response, the hail monitor array (HMA) system, a joint effort of the Applied Physics Laboratory operated by NASA and ASRC Aerospace at KSC, was deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow (CoCoRaHS) network, in conjunction with Colorado State University, continue to test duplicate hail monitor systems deployed in the high plains of Colorado.

  1. Fermilab accelerator control system: Analog monitoring facilities

    Energy Technology Data Exchange (ETDEWEB)

    Seino, K.; Anderson, L.; Smedinghoff, J.

    1987-10-01

    Thousands of analog signals are monitored in different areas of the Fermilab accelerator complex. For general purposes, analog signals are sent over coaxial or twinaxial cables with varying lengths, collected at fan-in boxes and digitized with 12 bit multiplexed ADCs. For higher resolution requirements, analog signals are digitized at sources and are serially sent to the control system. This paper surveys ADC subsystems that are used with the accelerator control systems and discusses practical problems and solutions, and it describes how analog data are presented on the console system.

  2. Monitoring water distribution systems: understanding and managing sensor networks

    Directory of Open Access Journals (Sweden)

    D. D. Ediriweera

    2010-09-01

    Full Text Available Sensor networks are currently being trialed by the water distribution industry for monitoring complex distribution infrastructure. The paper presents an investigation in to the architecture and performance of a sensor system deployed for monitoring such a distribution network. The study reveals lapses in systems design and management, resulting in a fifth of the data being either missing or erroneous. Findings identify the importance of undertaking in-depth consideration of all aspects of a large sensor system with access to either expertise on every detail, or to reference manuals capable of transferring the knowledge to non-specialists. First steps towards defining a set of such guidelines are presented here, with supporting evidence.

  3. Honey Bee Colonies Remote Monitoring System

    Science.gov (United States)

    Gil-Lebrero, Sergio; Quiles-Latorre, Francisco Javier; Ortiz-López, Manuel; Sánchez-Ruiz, Víctor; Gámiz-López, Victoria; Luna-Rodríguez, Juan Jesús

    2016-01-01

    Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD). The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee) based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time. PMID:28036061

  4. Honey Bee Colonies Remote Monitoring System

    Directory of Open Access Journals (Sweden)

    Sergio Gil-Lebrero

    2016-12-01

    Full Text Available Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD. The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time.

  5. Wearable system for vital signs monitoring.

    Science.gov (United States)

    Paradiso, Rita; Loriga, Gianni; Taccini, Nicola

    2004-01-01

    A new concept in healthcare, aimed at providing continuous remote monitoring of user's vital signs, is emerging. An innovative system named WEALTHY is presented, where conducting and piezoresistive materials in the form of fiber and yarn are integrated and used as sensor and electrode elements. The simultaneous recording of vital signs allows parameter extrapolation and inter-signal elaboration that contribute to producing alert messages and synoptic patient tables. Cardiac patients in the rehabilitation phase can be continuously monitored during selected time intervals, such as during physical activity or occurrence of symptoms, to discover potential threats and generate appropriate alerts to the patient and/or to an emergency center. The core of the system sensing is a textile interface, in which the sensing components are elements of the fabric: the sensorized garment is comfortable like a common article of clothing and is made with knitting machines; furthermore, the position of the electrodes and sensors is fixed and the elasticity of the fabric allows a good fitting to the body. The system is provided with a portable electronic unit, where signals are acquired, elaborated and transmitted. A monitoring system allows extrapolation of a new physiological index and data flow coordination as well as alarm management and database creation.

  6. Valve Health Monitoring System Utilizing Smart Instrumentation

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  7. Ground Truth Observations of the Interior of a Rockglacier as Validation for Geophysical Monitoring Data Sets

    Science.gov (United States)

    Hilbich, C.; Roer, I.; Hauck, C.

    2007-12-01

    Monitoring the permafrost evolution in mountain regions is currently one of the important tasks in cryospheric studies as little data on past and present changes of the ground thermal regime and its material properties are available. In addition to recently established borehole temperature monitoring networks, techniques to determine and monitor the ground ice content have to be developed. A reliable quantification of ground ice is especially important for modelling the thermal evolution of frozen ground and for assessing the hazard potential due to thawing permafrost induced slope instability. Near surface geophysical methods are increasingly applied to detect and monitor ground ice occurrences in permafrost areas. Commonly, characteristic values of electrical resistivity and seismic velocity are used as indicators for the presence of frozen material. However, validation of the correct interpretation of the geophysical parameters can only be obtained through boreholes, and only regarding vertical temperature profiles. Ground truth of the internal structure and the ice content is usually not available. In this contribution we will present a unique data set from a recently excavated rockglacier near Zermatt/Valais in the Swiss Alps, where an approximately 5 m deep trench was cut across the rockglacier body for the construction of a ski track. Longitudinal electrical resistivity tomography (ERT) and refraction seismic tomography profiles were conducted prior to the excavation, yielding data sets for cross validation of commonly applied geophysical interpretation approaches in the context of ground ice detection. A recently developed 4-phase model was applied to calculate ice-, air- and unfrozen water contents from the geophysical data sets, which were compared to the ground truth data from the excavated trench. The obtained data sets will be discussed in the context of currently established geophysical monitoring networks in permafrost areas. In addition to the

  8. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  9. Irreducible descriptive sets of attributes for information systems

    KAUST Repository

    Moshkov, Mikhail

    2010-01-01

    The maximal consistent extension Ext(S) of a given information system S consists of all objects corresponding to attribute values from S which are consistent with all true and realizable rules extracted from the original information system S. An irreducible descriptive set for the considered information system S is a minimal (relative to the inclusion) set B of attributes which defines exactly the set Ext(S) by means of true and realizable rules constructed over attributes from the considered set B. We show that there exists only one irreducible descriptive set of attributes. We present a polynomial algorithm for this set construction. We also study relationships between the cardinality of irreducible descriptive set of attributes and the number of attributes in S. The obtained results will be useful for the design of concurrent data models from experimental data. © 2010 Springer-Verlag.

  10. Production monitoring system for understanding product robustness

    DEFF Research Database (Denmark)

    Boorla, Srinivasa Murthy; Howard, Thomas J.

    2016-01-01

    In the current quality paradigm, the performance of a product is kept within specification by ensuring that its parts are within specification. Product performance is then validated after final assembly. However, this does not control how robust the product performance is, i.e. how much...... it will vary between the specification limits. In this paper, a model for predicting product performance is proposed, taking into account design, assembly and process parameters live from production. This empowers production to maintain final product performance, instead of part quality. The PRECI‐IN case...... study is used to demonstrate how the monitoring system can be used to efficiently guide corrective action to improve product performance. It is claimed that the monitoring system can be used to dramatically cut the time taken to identify, planand execute corrective action related to typical quality...

  11. A remote drip infusion monitoring system employing Bluetooth.

    Science.gov (United States)

    Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton

    2012-01-01

    We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.

  12. Wireless system for seismic activity monitoring

    OpenAIRE

    Безвесільна, Олена Миколаївна; Козько, Констянтин Сергійович

    2014-01-01

    The article examines the concepts and principles of sensor networks operations, especially the one that is used to monitor seismic activity and potential natural disasters. It also describes the operating principle of the geographically distributed wireless system, represented by block diagrams of typical sensor nodes and base station, as well as constructive electrical circuit sensor node and the frequency generator radio transmissions the base station and sensor nodes, we formulate to calcu...

  13. 30 CFR 77.312 - Fail safe monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe monitoring systems. 77.312 Section 77... Thermal Dryers § 77.312 Fail safe monitoring systems. Thermal dryer systems and controls shall be protected by a fail safe monitoring system which will safely shut down the system and any related...

  14. Feasibility of adjacent insulin infusion and continuous glucose monitoring via the Medtronic Combo-Set.

    Science.gov (United States)

    O'Neal, David N; Adhya, Sumona; Jenkins, Alicia; Ward, Glenn; Welsh, John B; Voskanyan, Gayane

    2013-03-01

    Subcutaneously infused insulin may interfere with the function of nearby glucose-sensing electrodes and vice versa. The prototype of the Combo-Set device (Medtronic) incorporates a subcutaneous insulin delivery catheter and continuous glucose monitoring (CGM) sensor assembled on the same platform and separated by 11 mm. We aim to evaluate Combo-Set's insulin delivery and glucose-sensing functions. Ten subjects with type 1 diabetes wore a Combo-Set and a Sof-Sensor inserted subcutaneously in contralateral abdominal areas connected to iPro recorders (Medtronic) for 53.25 ± 0.75 h (mean ± standard deviation). The Combo-Set delivered insulin diluent except during meal tests on days 1 and 3 when insulin lispro was delivered as a meal bolus and postmeal basal. Venous plasma samples were collected at the following time points from meal start: 0, 30, 60, 120, and 180 min for insulin measurements. The accuracy of the Combo-Set sensors was evaluated and compared with that of the Sof-Sensor, with each referenced against capillary glucose values (Contour Link Meter, Bayer). Accuracy of the Combo-Set sensor was comparable to that of the Sof-Sensor. Clarke error grid analysis showed that 97% of Combo-Set and 93% of Sof-Sensor values were in the A+B regions (p = .20, not significant). The Combo-Set showed the expected postbolus peak insulin time (67 ± 9 min, mean ± standard error). One "no delivery" alarm occurred during the 21 patient days of use. A device providing for simultaneous adjacent placement of an insulin infusion catheter and a CGM sensor is feasible and functions within acceptable limits. The low "no delivery" alarm rate was similar to that of other infusion sets. © 2013 Diabetes Technology Society.

  15. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States); Carelsen, Bart [Philips HealthCare, Clinical Science Interventional X-ray (Netherlands); Diehm, Nicolas [Kantonsspital Aarau, Clinical and Interventional Angiology (Switzerland); Benenati, James F.; Peña, Constantino S. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States)

    2015-10-15

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

  16. Expert System for Test Program Set Fault Candidate Selection

    Science.gov (United States)

    1989-09-01

    This report describes an application of expert system technology to test program set (TPS) verification and validation. The goals of this project are...Keywords: Expert system , Artificial intelligence, Automatic test equipment (ATE), Test program set (TPS), Automatic test program generation (ATPG), Fault inspection, Verification and validation, TPS acceptance tool.

  17. Logical Discrete Event Systems in a trace theory based setting

    NARCIS (Netherlands)

    Smedinga, R.

    1993-01-01

    Discrete event systems can be modelled using a triple consisting of some alphabet (representing the events that might occur), and two trace sets (sets of possible strings) denoting the possible behaviour and the completed tasks of the system. Using this definition we are able to formulate and solve

  18. Localization of Compact Invariant Sets of the Lorenz'1984 System

    Directory of Open Access Journals (Sweden)

    Kh. M. Ramazanova

    2015-01-01

    Full Text Available Localization of compact invariant sets of a dynamical system is one way to conduct a qualitative analysis of dynamical system. The localization task is aimed at evaluating the location of invariant compact sets of systems, which are equilibrium, periodic trajectories, attractors and repellers, and invariant tori. Such sets and their properties largely determine the structure of the phase portrait of the system. For this purpose, one can use a localization set, i.e. a set in the phase space of the system that contains all invariant compact sets.This article considers the problem of localization of invariant compact sets of an Autonomous version of the Lorenz-84 system. The system represents a simple model of the General circulation of the atmosphere in middle latitudes. The model was used in various climatological studies. To build localization set of the system the so-called functional localization method is applied. The article describes the main provisions of this method, lists the main properties of the localization sets. The simplest version of the Lorenz-84 system when there are no thermal loads is analyzed, and a common variant of the Autonomous Lorenz-84 system, in which for some values of system parameters chaotic dynamics occurs is investigated. In the first case it is shown that the only invariant compact set of the system is its equilibrium position, and localization function turned out to be a Lyapunov function of the system. For the General version of the system a family of localization sets is built and the intersection of this family is described. Graphical illustration for the localization set at fixed values of the parameters is shown. The result of the study partially overlaps with the result of K.E. Starkov on the subject, but provides additional information.The theme of localization of invariant compact sets is discussed quite actively in the literature. Research focuses both on the development of the method and its

  19. The system of generalized set-valued equilibrium problems

    Directory of Open Access Journals (Sweden)

    Peng Jian-Wen

    2006-01-01

    Full Text Available We introduce new and interesting model of system of generalized set-valued equilibrium problems which generalizes and unifies the system of set-valued equilibrium problems, the system of generalized implicit vector variational inequalities, the system of generalized vector and vector-like variational inequalities introduced by Ansari et al. (2002, the system of generalized vector variational inequalities presented by Allevi et al. (2001, the system of vector equilibrium problems and the system of vector variational inequalities given by Ansari et al. (2000, the system of scalar variational inequalities presented by Ansari Yao (1999, 2000, Bianchi (1993, Cohen and Caplis (1988, Konnov (2001, and Pang (1985, the system of Ky-Fan variational inequalities proposed bt Deguire et al. (1999 as well as a variety of equilibrium problems in the literature. Several existence results of a solution for the system of generalized set-valued equilibrium problems will be shown.

  20. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  1. Low temperature monitoring system for subsurface barriers

    Science.gov (United States)

    Vinegar, Harold J.; McKinzie, II. Billy John

    2009-08-18

    A system for monitoring temperature of a subsurface low temperature zone is described. The system includes a plurality of freeze wells configured to form the low temperature zone, one or more lasers, and a fiber optic cable coupled to at least one laser. A portion of the fiber optic cable is positioned in at least one freeze well. At least one laser is configured to transmit light pulses into a first end of the fiber optic cable. An analyzer is coupled to the fiber optic cable. The analyzer is configured to receive return signals from the light pulses.

  2. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  3. Master Console System Monitoring and Control Development

    Science.gov (United States)

    Brooks, Russell A.

    2013-01-01

    The Master Console internship during the summer of 2013 involved the development of firing room displays and support applications at the John F. Kennedy Space Center (KSC). This position was with the Master Console Product Group (MCPG) on the Launch Control System (LCS) project. This project is responsible for the System Monitoring and Control (SMC) and Record and Retrieval (R&R) of launch operations data. The Master Console is responsible for: loading the correct software into each of the remaining consoles in the firing room, connecting the proper data paths to and from the launch vehicle and all ground support equipment, and initializing the entire firing room system to begin processing. During my internship, I created control scripts using the Application Control Language (ACL) to analyze the health and status of Kennedy Ground Control System (KGCS) programmable logic controllers (PLCs). This application provides a system health and status display I created with summarized data for use by Master Console Operators (MCO) to monitor and verify the integrity of KGCS subsystems.

  4. Downhole Vibration Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2007-09-30

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. The key feature of this system is its use of a magnetorheological fluid (MRF) to allow the damping coefficient to be changed extensively, rapidly and reversibly without the use of mechanical valves, but only by the application of a current. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Much of the effort was devoted to the design and testing of the MRF damper, itself. The principal objectives of Phase II were: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in a drilling laboratory. Phase II concluded on January 31, 2006, and a final report was issued. Work on Phase III of the project began during the first quarter, 2006, with the objectives of building precommercial prototypes, testing them in a drilling laboratory and the field; developing and implementing a commercialization plan. All of these have been accomplished. The Downhole Vibration Monitoring & Control System (DVMCS) prototypes have been successfully proven in testing at the TerraTek drilling facility and at the Rocky Mountain Oilfield Test Center (RMOTC.) Based on the results of these tests, we have signed a definitive development and distribution agreement with Smith, and commercial deployment is underway. This current version of the DVMCS monitors and controls axial vibrations. Due to time and budget constraints of this program, it was not possible to complete a system that would also deal with lateral and torsional (stick-slip) vibrations as originally planned; however, this effort is continuing without DOE

  5. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  6. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  7. Promoting community participation in priority setting in district health systems

    DEFF Research Database (Denmark)

    Kamuzora, Peter; Maluka, Stephen; Ndawi, Benedict

    2013-01-01

    Community participation in priority setting in health systems has gained importance all over the world, particularly in resource-poor settings where governments have often failed to provide adequate public-sector services for their citizens. Incorporation of public views into priority setting...... of implementing community participation and the challenges of promoting it in the context of resource-poor settings, weak organizations, and fragile democratic institutions....... is perceived as a means to restore trust, improve accountability, and secure cost-effective priorities within healthcare. However, few studies have reported empirical experiences of involving communities in priority setting in developing countries. The aim of this article is to provide the experience...

  8. SEMS: System for Environmental Monitoring and Sustainability

    Science.gov (United States)

    Arvidson, Raymond E.

    1998-01-01

    The goal of this project was to establish a computational and data management system, SEMS, building on our existing system and MTPE-related research. We proposed that the new system would help support Washington University's efforts in environmental sustainability through use in: (a) Problem-based environmental curriculum for freshmen and sophomores funded by the Hewlett Foundation that integrates scientific, cultural, and policy perspectives to understand the dynamics of wetland degradation, deforestation, and desertification and that will develop policies for sustainable environments and economies; (b) Higher-level undergraduate and graduate courses focused on monitoring the environment and developing policies that will lead to sustainable environmental and economic conditions; and (c) Interdisciplinary research focused on the dynamics of the Missouri River system and development of policies that lead to sustainable environmental and economic floodplain conditions.

  9. Radiation portal monitor system and method

    Science.gov (United States)

    Morris, Christopher; Borozdin, Konstantin N.; Green, J. Andrew; Hogan, Gary E.; Makela, Mark F.; Priedhorsky, William C.; Saunders, Alexander; Schultz, Larry J.; Sossong, Michael J.

    2009-12-15

    A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  10. A novel electric power quality monitoring system for transient analysis

    OpenAIRE

    2014-01-01

    Electricity is vital for our daily life in modern cites. In order to ensure its reliability and supply, an electric power monitoring system is indispensable in an electric power system. Currently, most electric power monitoring systems are designed for steady-state monitoring only. They may not be able to monitor instantaneous power disturbances, such as voltage surge, happened in electric power systems. In fact, instantaneous power disturbances are frequently found in electric power systems,...

  11. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, Tjeerd; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with deve

  12. Condition monitoring for a neutral beam injector cryopumping system

    Energy Technology Data Exchange (ETDEWEB)

    Wright, N., E-mail: n.wright@lboro.ac.uk [School of Electronic and Electrical Engineering, Loughborough University, Loughborough LE11 3TU (United Kingdom); Dixon, R., E-mail: r.dixon@lboro.ac.uk [School of Electronic and Electrical Engineering, Loughborough University, Loughborough LE11 3TU (United Kingdom); Verhoeven, R., E-mail: roel.verhoeven@ccfe.ac.uk [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2013-10-15

    Highlights: ► The development of a cryopumping condition monitoring scheme is presented. ► A residual generation scheme is used to detect two faults. ► Kalman filtering is used to generate the residuals. ► A filtering and voting arrangement is used to evaluate the residuals. ► A non-linear simulation model is used to verify the scheme. -- Abstract: For neutral beam injection systems, the maintenance of a vacuum inside the injector box is essential for normal operation. Cryogenic pumping systems are often used to create and maintain this vacuum. Cryogenic pumping systems have been deployed on the neutral beam heating systems supporting the Joint European Torus. With these as a target application, the development of a condition monitoring scheme is presented. The scheme uses a residual generation approach. A bank of Kalman filters is used to estimate measured process variables. A residual evaluator is used to map residual signals onto a set of faults. Two example faults are simulated to demonstrate the response of the scheme. This paper contributes to the wider fusion development programme by demonstrating how a contemporary condition monitoring technique can be applied to a fusion support system, in order to improve its availability.

  13. Internal ellipsoidal estimates of reachable set of impulsive control systems

    Energy Technology Data Exchange (ETDEWEB)

    Matviychuk, Oksana G. [Institute of Mathematics and Mechanics, Russian Academy of Sciences, 16 S. Kovalevskaya str., Ekaterinburg, 620990, Russia and Ural Federal University, 19 Mira str., Ekaterinburg, 620002 (Russian Federation)

    2014-11-18

    A problem of estimating reachable sets of linear impulsive control system with uncertainty in initial data is considered. The impulsive controls in the dynamical system belong to the intersection of a special cone with a generalized ellipsoid both taken in the space of functions of bounded variation. Assume that an ellipsoidal state constraints are imposed. The algorithms for constructing internal ellipsoidal estimates of reachable sets for such control systems and numerical simulation results are given.

  14. Generalized rough sets based on neighborhood systems and topological spaces

    Directory of Open Access Journals (Sweden)

    R. Mareay

    2016-10-01

    Full Text Available Rough sets theory is an important method for dealing with uncertainty, fuzziness and undefined objects. In this paper, we introduce a new approach for generalized rough sets based on the neighborhood systems induced by an arbitrary binary relation. Four pairs of the dual approximation operators are generated from the core of neighborhood systems. Relationship among different approximation operators are presented. We generate different topological spaces by using the core of these neighborhood systems. Relationship among different generated topologies are discussed.

  15. Research on Integrated Monitoring and Prevention System for Stray Current in Metro

    Institute of Scientific and Technical Information of China (English)

    李威; 严旭

    2001-01-01

    On the basis of analyzing the influencing factors and harmfulness of stray current, and discussing the existing problems of monitoring and prevention system for stray current, the integrated monitoring and prevention system for stray current in metro was developed. A net system of distributed computers for monitoring was set up. It can monitor the distribution of stray current in metro and the corrosion of the metal structure in the whole line. According to the situation of monitoring it can also control the drainage of its tank to reach the best effect and eliminate the negative effect of polarity drainage. By using the new type unilateral electric device, the problem of burning the rail by electric arc can be avoided. The unilateral electric device can be connected with the monitoring net system directly to realize the monitor in line and improve the reliability of the device.

  16. Applied Data Analysis in Energy Monitoring System

    Directory of Open Access Journals (Sweden)

    Kychkin А.V.

    2016-08-01

    Full Text Available Software and hardware system organization is presented as an example for building energy monitoring of multi-sectional lighting and climate control / conditioning needs. System key feature is applied office energy data analysis that allows to provide each type of hardware localized work mode recognition. It is based on general energy consumption profile with following energy consumption and workload evaluation. Applied data analysis includes primary data processing block, smoothing filter, time stamp identification block, clusterization and classification blocks, state change detection block, statistical data calculation block. Time slot consumed energy value and slot time stamp are taken as work mode classification main parameters. Energy data applied analysis with HIL and OpenJEVis visualization system usage experimental research results for chosen time period has been provided. Energy consumption, workload calculation and eight different states identification has been executed for two lighting sections and one climate control / conditioning emulating system by integral energy consumption profile. Research has been supported by university internal grant №2016/PI-2 «Methodology development of monitoring and heat flow utilization as low potential company energy sources».

  17. Research and Construction the Net Monitor System

    Directory of Open Access Journals (Sweden)

    Ruining Huang

    2012-07-01

    Full Text Available A Net Monitor system is presented in this paper. The system is based on STMicroelectronics board FLTK3D, which provides hardware platform for TV functions--3D film, IPTV, 3D game, cable television and so on. The whole system includes the Linux Operating System (OS, embedded web browser, Media player, clouding applications, video conference and 3D game. It utilizes the reference model of the CLFS (Cross Linux From Scratches principle to construct the embedded Linux OS. Cloud applications are focused on remote control and access to the cloud data center. The ESX/view client provides this function for its secure access to the data center and maintainability. With the development of IPTV technology, light cross-platform web browser, media player and video conference are implemented. The Net Monitor can integrate cloud applications, web browser, media player, video conference and so on in just one platform with lower cost than other platforms on buying extra hardware and software, so it will brings convenient and benefit to people.

  18. Installation and Operation of RENO Slow Control and Online Monitoring System

    CERN Document Server

    Choi, J H; Pac, M Y; Ahn, J K; Choi, S; Choi, Y; Choi, W K; Jang, J S; Jeon, E J; Joo, K K; Kim, H S; Kim, J Y; Kim, S B; Kim, W; Kim, Y D; Lee, J; Lim, I T; Ma, K J; Park, I G; Park, J S; Park, K S; Shin, J W; K, Siyeon; Stepanyan, S S; Yeo, I S; Yu, I

    2013-01-01

    The RENO is the reactor based experiment to measure the smallest neutrino mixing angle, $\\theta_{13}$. The slow control and online monitoring system for RENO monitors the status of the HV systems, the temperatures of the electronics crates and detectors, the fluids levels, humidities of experimental halls and electronics huts, and gas concentrations. And the slow control system is able to set up high voltage for each channel and turn on and off HV remotely. An online monitoring system located in the control room reads data from the DAQ host computer via network. It provides event display, online histograms to monitor detector performance, and variety of additional tasks needed to efficiently monitor detector performance parameters and diagnose troubles of detector and DAQ system. In this paper, we explan the installation of the slow control and monitoring system and their operation status,

  19. Embedded multiparametric system for volcano monitoring

    Science.gov (United States)

    Moure, David; Torres, Pedro A.; Meletlidis, Stavros; Lopez, Carmen; José Blanco, María

    2014-05-01

    A low cost and low power consumption multiparametric system designed for volcano monitoring is presented. Once tested with various sensors, at present it is installed in two locations in Tenerife, Canary Islands, acquiring and transmitting data in real time. The system is based on a commercial board (Raspberry Pi®, RPi®) that uses an embedded ARMTM processor with a Debian (Wheezy-Raspbian) Linux Operating System. This configuration permits different standard communication systems between devices as USB and ETHERNET, and also communication with integrated circuits is possible. The whole system includes this platform and self-developed hardware and software. Analog signals are acquired at an expansion board with an ADC converter with three 16 bits channels. This board, which is powered directly from the RPi®, provides timing to the sampling data using a Real Time Clock (RTC). Two serial protocols (I2C and SPI) are responsible for communications. Due to the influence of atmospheric phenomena on the volcano monitoring data, the system is complemented by a self-developed meteorological station based on ArduinoCC and low cost commercial sensors (atmospheric pressure, humidity and rainfall). It is powered with the RPi® and it uses a serial protocol for communications. Self-developed software run under Linux OS and handles configuration, signal acquisition, data storage (USB storage or SD card) and data transmission (FTP, web server). Remote configuration, data plotting and downloading is available through a web interface tool. Nowadays, the system is used for gravimetric and oceanic tides data acquisition in Tenerife and soon it will be applied for clinometric data.

  20. The LCLS Undulator Beam Loss Monitor Readout System

    Energy Technology Data Exchange (ETDEWEB)

    Dusatko, John; Browne, M.; Fisher, A.S.; Kotturi, D.; Norum, S.; Olsen, J.; /SLAC

    2012-07-23

    The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

  1. [Portable Epileptic Seizure Monitoring Intelligent System Based on Android System].

    Science.gov (United States)

    Liang, Zhenhu; Wu, Shufeng; Yang, Chunlin; Jiang, Zhenzhou; Yu, Tao; Lu, Chengbiao; Li, Xiaoli

    2016-02-01

    The clinical electroencephalogram (EEG) monitoring systems based on personal computer system can not meet the requirements of portability and home usage. The epilepsy patients have to be monitored in hospital for an extended period of time, which imposes a heavy burden on hospitals. In the present study, we designed a portable 16-lead networked monitoring system based on the Android smart phone. The system uses some technologies including the active electrode, the WiFi wireless transmission, the multi-scale permutation entropy (MPE) algorithm, the back-propagation (BP) neural network algorithm, etc. Moreover, the software of Android mobile application can realize the processing and analysis of EEG data, the display of EEG waveform and the alarm of epileptic seizure. The system has been tested on the mobile phones with Android 2. 3 operating system or higher version and the results showed that this software ran accurately and steadily in the detection of epileptic seizure. In conclusion, this paper provides a portable and reliable solution for epileptic seizure monitoring in clinical and home applications.

  2. Process monitoring using ultrasonic sensor systems.

    Science.gov (United States)

    Henning, Bernd; Rautenberg, Jens

    2006-12-22

    Continuous in-line measurement of substance concentration in liquid mixtures is valuable in improving industrial processes in terms of material properties, energy efficiency and process safety. Ultrasonic sensor systems meet the practical requirements of a chemical sensor quite well. Currently ultrasonic sensor systems are widely used as acoustic chemical sensors to measure concentration of selected substances or to monitor the course of polymerisation, crystallisation or fermentation processes. Useable acoustic properties for the characterisation of liquid mixtures are sound velocity, sound absorption and acoustic impedance. This contribution will give a short overview of the state of the art and several trends for the use of ultrasonic sensor systems in process applications. Novel investigations show the very promising possibility to analyse liquid multi-phase mixtures like suspensions, emulsions and dispersions.

  3. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    , and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program......A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface...

  4. Smart Garbage Monitoring System for Waste Management

    Directory of Open Access Journals (Sweden)

    Mohd Yusof Norfadzlia

    2017-01-01

    Full Text Available Piles of rubbish are one of the major problems faced by most people in Malaysia, especially those who live in flats, as the number of bins is limited and shared among all residents. It may cause pollutions, which may lead to sanitary issues and diseases. This project presents the development of a smart garbage monitoring system in order to measure waste level in the garbage bin in real-time and to alert the municipality, in particular cases, via SMS. The proposed system is consisted by the ultrasonic sensor to measure the waste level, the GSM module to send the SMS, and an Arduino Uno which controls the system operation. It supposes to generate and send the warning messages to the municipality via SMS when the waste bin is full or almost full, so the garbage can be collected immediately. Furthermore, it is expected to contribute to improving the efficiency of the solid waste disposal management.

  5. Automatic outdoor monitoring system for photovoltaic panels

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  6. Monitoring the LHCb data quality system

    CERN Multimedia

    Baranov, Alexander

    2016-01-01

    Monitoring the quality of the data, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the apparatus during the data taking. DQM at LHCb is carried out in two phase. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs with some delay. For the Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator's task, Monet is also equipped with an automated, fully configurable, alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation.

  7. Automatic outdoor monitoring system for photovoltaic panels.

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  8. Prometheus: a next-generation monitoring system

    CERN Document Server

    CERN. Geneva

    2017-01-01

    Prometheus is an open eco-system that provides an end-to-end approach to infrastructure and application monitoring. It covers all levels beginning with easy instrumentation based on a flexible, multi-dimensional data model. The Prometheus server itself collects and stores time series while trying to maintain operational simplicity while being adaptable to varying scales and layouts of infrastructure. By integrating with a wide range of service discovery systems, it always stays in sync with the world it is monitoring. The powerful query language allows us to ask complex questions and can be applied seamlessly between ad-hoc investigation and static dashboarding. It is also directly applied in the eco-system's alerting layer, which favors a time-series based over and event driven approach. In this talk we will look at all aspects of Prometheus from the high-level philosophy behind its design to its practical concerns of implementation and operation. About the speaker Fabian Reinartz is a software eng...

  9. Automatic outdoor monitoring system for photovoltaic panels

    Energy Technology Data Exchange (ETDEWEB)

    Stefancich, Marco [Consiglio Nazionale delle Ricerce, Istituto dei Materiali per l’Elettronica ed il Magnetismo (CNR-IMEM), Parco Area delle Scienze 37/A, 43124 Parma, Italy; Simpson, Lin [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA; Chiesa, Matteo [Masdar Institute of Science and Technology, P.O. Box 54224, Masdar City, Abu Dhabi, United Arab Emirates

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  10. Monitoring and analyzing features of electrical power quality system performance

    Directory of Open Access Journals (Sweden)

    Genci Sharko

    2010-06-01

    Full Text Available Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many more causes of such poor quality power. Power quality of power systems, which affects all connected electrical and electronic equipment, is a measure of deviations in voltages, currents, frequency, temperatures, winding forces and torques of particular supply systems and their components. In recent years, a considerable increase in nonlinear loads has been experienced; in particular distributed loads, such as computers, monitors and lighting, and distributed sources. The aim of this paper is to display a way of monitoring and analyzing features of electrical power quality system. As a monitoring example is taken output from power transformer rated at 320 kVA, part of distribution grid of Durres City in Albania.

  11. Improved Stochastic Subspace System Identification for Structural Health Monitoring

    Science.gov (United States)

    Chang, Chia-Ming; Loh, Chin-Hsiung

    2015-07-01

    Structural health monitoring acquires structural information through numerous sensor measurements. Vibrational measurement data render the dynamic characteristics of structures to be extracted, in particular of the modal properties such as natural frequencies, damping, and mode shapes. The stochastic subspace system identification has been recognized as a power tool which can present a structure in the modal coordinates. To obtain qualitative identified data, this tool needs to spend computational expense on a large set of measurements. In study, a stochastic system identification framework is proposed to improve the efficiency and quality of the conventional stochastic subspace system identification. This framework includes 1) measured signal processing, 2) efficient space projection, 3) system order selection, and 4) modal property derivation. The measured signal processing employs the singular spectrum analysis algorithm to lower the noise components as well as to present a data set in a reduced dimension. The subspace is subsequently derived from the data set presented in a delayed coordinate. With the proposed order selection criteria, the number of structural modes is determined, resulting in the modal properties. This system identification framework is applied to a real-world bridge for exploring the feasibility in real-time applications. The results show that this improved system identification method significantly decreases computational time, while qualitative modal parameters are still attained.

  12. Inherently safe passive gas monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Cordaro, Joseph V.; Bellamy, John Stephen; Shuler, James M.; Shull, Davis J.; Leduc, Daniel R.

    2016-09-06

    Generally, the present disclosure is directed to gas monitoring systems that use inductive power transfer to safely power an electrically passive device included within a nuclear material storage container. In particular, the electrically passive device can include an inductive power receiver for receiving inductive power transfer through a wall of the nuclear material storage container. The power received by the inductive power receiver can be used to power one or more sensors included in the device. Thus, the device is not required to include active power generation components such as, for example, a battery, that increase the risk of a spark igniting flammable gases within the container.

  13. Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs

    Directory of Open Access Journals (Sweden)

    Daniel P. Howsmon

    2017-01-01

    Full Text Available Reliable continuous glucose monitoring (CGM enables a variety of advanced technology for the treatment of type 1 diabetes. In addition to artificial pancreas algorithms that use CGM to automate continuous subcutaneous insulin infusion (CSII, CGM can also inform fault detection algorithms that alert patients to problems in CGM or CSII. Losses in infusion set actuation (LISAs can adversely affect clinical outcomes, resulting in hyperglycemia due to impaired insulin delivery. Prolonged hyperglycemia may lead to diabetic ketoacidosis—a serious metabolic complication in type 1 diabetes. Therefore, an algorithm for the detection of LISAs based on CGM and CSII signals was developed to improve patient safety. The LISA detection algorithm is trained retrospectively on data from 62 infusion set insertions from 20 patients. The algorithm collects glucose and insulin data, and computes relevant fault metrics over two different sliding windows; an alarm sounds when these fault metrics are exceeded. With the chosen algorithm parameters, the LISA detection strategy achieved a sensitivity of 71.8% and issued 0.28 false positives per day on the training data. Validation on two independent data sets confirmed that similar performance is seen on data that was not used for training. The developed algorithm is able to effectively alert patients to possible infusion set failures in open-loop scenarios, with limited evidence of its extension to closed-loop scenarios.

  14. Remote monitoring of LED lighting system performance

    Science.gov (United States)

    Thotagamuwa, Dinusha R.; Perera, Indika U.; Narendran, Nadarajah

    2016-09-01

    The concept of connected lighting systems using LED lighting for the creation of intelligent buildings is becoming attractive to building owners and managers. In this application, the two most important parameters include power demand and the remaining useful life of the LED fixtures. The first enables energy-efficient buildings and the second helps building managers schedule maintenance services. The failure of an LED lighting system can be parametric (such as lumen depreciation) or catastrophic (such as complete cessation of light). Catastrophic failures in LED lighting systems can create serious consequences in safety critical and emergency applications. Therefore, both failure mechanisms must be considered and the shorter of the two must be used as the failure time. Furthermore, because of significant variation between the useful lives of similar products, it is difficult to accurately predict the life of LED systems. Real-time data gathering and analysis of key operating parameters of LED systems can enable the accurate estimation of the useful life of a lighting system. This paper demonstrates the use of a data-driven method (Euclidean distance) to monitor the performance of an LED lighting system and predict its time to failure.

  15. 30 CFR 27.21 - Methane-monitoring system.

    Science.gov (United States)

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane...-monitoring system are functioning normally. (b) A methane-monitoring system shall be rugged in construction so that its operation will not be affected by vibration or physical shock, such as normally...

  16. A Wireless Distributed Condition Monitoring System Based on Bluetooth Technology

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Based on the discussion of bluetooth and network technology, this paper proposed an entire framework of a wireless distributed monitoring system by combining the characteristics of industry application. The feasibility of putting this kind of system in practice is discussed. The wireless distributed monitoring system can enhance the performance of condition monitoring more than the traditional one used now.

  17. A three-tier framework for monitoring antiretroviral therapy in high HIV burden settings

    Directory of Open Access Journals (Sweden)

    Meg Osler

    2014-04-01

    Full Text Available The provision of antiretroviral therapy (ART in low and middle-income countries is a chronic disease intervention of unprecedented magnitude and is the dominant health systems challenge for high-burden countries, many of which rank among the poorest in the world. Substantial external investment, together with the requirement for service evolution to adapt to changing needs, including the constant shift to earlier ART initiation, makes outcome monitoring and reporting particularly important. However, there is growing concern at the inability of many high-burden countries to report on the outcomes of patients who have been in care for various durations, or even the number of patients in care at a particular point in time. In many instances, countries can only report on the number of patients ever started on ART. Despite paper register systems coming under increasing strain, the evolution from paper directly to complex electronic medical record solutions is not viable in many contexts. Implementing a bridging solution, such as a simple offline electronic version of the paper register, can be a pragmatic alternative. This paper describes and recommends a three-tiered monitoring approach in low- and middle-income countries based on the experience implementing such a system in the Western Cape province of South Africa. A three-tier approach allows Ministries of Health to strategically implement one of the tiers in each facility offering ART services. Each tier produces the same nationally required monthly enrolment and quarterly cohort reports so that outputs from the three tiers can be aggregated into a single database at any level of the health system. The choice of tier is based on context and resources at the time of implementation. As resources and infrastructure improve, more facilities will transition to the next highest and more technologically sophisticated tier. Implementing a three-tier monitoring system at country level for pre

  18. Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    Energy Technology Data Exchange (ETDEWEB)

    Fehlau, P.E.; Coop, K.; Garcia, C. Jr.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium. 6 references, 9 figures, 2 tables.

  19. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  20. The Monitor online system of the OPERA muon magnetic spectrometer

    CERN Document Server

    Ugolino, U.; Acquafredda, R.; Masone, v.

    2008-01-01

    The OPERA muon magnetic spectrometer has been designed for muon detection, tracking and timing. The 44 bakelite Resistive Chambers (RPC) planes, imbibed inside the magnet iron slabs, must provide the tracking of the muon curved in the magnetic field to ease the momentum and charge measurement provided by the HPT. Furthermore, it provides the momentum for muons stopping in the iron. RPC signals will be also used as start of drift tube acquisition thanks to the very good time resolution of RPC detectors. Due to the required performances the tracking detector must be fully efficient and stable. In this conditions an online monitor is mandatory to continuously control stability of run conditions. We report the main characteristics and performances of the monitor system for the OPERA spectrometer and capabilities of the software developed for settings and data acquisition.

  1. An Autonomous Long Range Monitoring System For Emergency Operators

    CERN Document Server

    Lanati, Matteo; Secco, Emanuele Lindo; Magenes, Giovanni; Gamba, Paolo

    2011-01-01

    Miniaturization and portability of new electronics lead up to wearable devices embedded within garments: a European program called ProeTEX developed multi-purpose sensors integrated within emergency operators' garments in order to monitor their health state and the surrounding environment. This work deals with the development of an autonomous Long Range communication System (LRS), suitable to transmit data between operators' equipment and the local command post, where remote monitoring software is set up. The LRS infrastructure is based on Wi-Fi protocol and modular architecture. Field tests carried out on the developed prototype showed a high reliability in terms of correctly exchanged data and recovering capabilities in case of temporary disconnection, due to the operator's movements.

  2. Requirements of CLIC Beam Loss Monitoring System

    CERN Document Server

    Sapinski, M; Holzer, EB; Jonker, M; Mallows, S; Otto, T; Welsch, C

    2010-01-01

    The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

  3. Data Quality Assurance Techniques for a Monitoring and Diagnosis System

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By researching the data quality problem in the monitoring and diagnosis system (MDS),the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.

  4. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    Directory of Open Access Journals (Sweden)

    Emanuel Heinz

    2013-12-01

    Full Text Available We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS for stable water isotope analysis (δ2H and δ18O, a reagentless hyperspectral UV photometer (ProPS for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system’s technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season.

  5. Simultaneous real-time monitoring of multiple cortical systems

    Science.gov (United States)

    Gupta, Disha; Hill, N. Jeremy; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L.; Schalk, Gerwin

    2014-10-01

    Objective. Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. Approach. We study these questions using electrocorticographic signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (six for offline parameter optimization, six for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main results. Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelopes. These decoders were trained separately and executed simultaneously in real time. Significance. This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple

  6. Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

    Science.gov (United States)

    Iverson, David L. (Inventor)

    2008-01-01

    The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

  7. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings

    NARCIS (Netherlands)

    Li, Xiao; Ymeti, Aurel; Lunter, Björn; Breukers, Christian; Tibbe, Arjan G.J.; Terstappen, Leon W.M.M.; Greve, Jan

    2007-01-01

    Backround: HIV monitoring in resource-constrained settings demands affordable and reliable CD4+ T lymphocytes enumeration methods. We developed a simple single platform image cytometer (SP ICM), which is a dedicated volumetric CD4+ T lymphocytes enumeration system that uses immunomagnetic and immuno

  8. Monitoring and Commissioning Verification Algorithms for CHP Systems

    Energy Technology Data Exchange (ETDEWEB)

    Brambley, Michael R.; Katipamula, Srinivas; Jiang, Wei

    2008-03-31

    This document provides the algorithms for CHP system performance monitoring and commissioning verification (CxV). It starts by presenting system-level and component-level performance metrics, followed by descriptions of algorithms for performance monitoring and commissioning verification, using the metric presented earlier. Verification of commissioning is accomplished essentially by comparing actual measured performance to benchmarks for performance provided by the system integrator and/or component manufacturers. The results of these comparisons are then automatically interpreted to provide conclusions regarding whether the CHP system and its components have been properly commissioned and where problems are found, guidance is provided for corrections. A discussion of uncertainty handling is then provided, which is followed by a description of how simulations models can be used to generate data for testing the algorithms. A model is described for simulating a CHP system consisting of a micro-turbine, an exhaust-gas heat recovery unit that produces hot water, a absorption chiller and a cooling tower. The process for using this model for generating data for testing the algorithms for a selected set of faults is described. The next section applies the algorithms developed to CHP laboratory and field data to illustrate their use. The report then concludes with a discussion of the need for laboratory testing of the algorithms on a physical CHP systems and identification of the recommended next steps.

  9. Molecular Imaging System for Monitoring Tumor Angiogenesis

    Science.gov (United States)

    Aytac, Esra; Burcin Unlu, Mehmet

    2012-02-01

    In cancer, non-invasive imaging techniques that monitor molecular processes associated with the tumor angiogenesis could have a central role in the evaluation of novel antiangiogenic and proangiogenic therapies as well as early detection of the disease. Matrix metalloproteinases (MMP) can serve as specific biological targets for imaging of angiogenesis since expression of MMPs is required for angiogenesis and has been found to be upregulated in every type of human cancer and correlates with stage, invasive, metastatic properties and poor prognosis. However, for most cancers it is still unknown when, where and how MMPs are involved in the tumor angiogenesis [1]. Development of high-resolution, high sensitivity imaging techniques in parallel with the tumor models could prove invaluable for assessing the physical location and the time frame of MMP enzymatic acitivity. The goal of this study is to understand where, when and how MMPs are involved in the tumor angiogenesis. We will accomplish this goal by following two objectives: to develop a high sensitivity, high resolution molecular imaging system, to develop a virtual tumor simulator that can predict the physical location and the time frame of the MMP activity. In order to achieve our objectives, we will first develop a PAM system and develop a mathematical tumor model in which the quantitative data obtained from the PAM can be integrated. So, this work will develop a virtual tumor simulator and a molecular imaging system for monitoring tumor angiogenesis. 1.Kessenbrock, K., V. Plaks, and Z. Werb, MMP:regulators of the tumor microenvironment. Cell, 2010. 141(1)

  10. NCPDP recommendations for dose accumulation monitoring in the inpatient setting: Acetaminophen case model, version 1.0.

    Science.gov (United States)

    2016-08-01

    Best practices and guidance are provided for improved electronic detection and alerting of inadvertent supratherapeutic cumulative doses of acetaminophen and other medications with narrow therapeutic ranges in inpatient settings. Despite the use of medication safety technologies, overdosage and associated sentinel events continue to be serious problems in many inpatient settings. The tools needed to monitor and employ dose alerts, accumulators, and warning systems are available to reduce inadvertent overdose. Required are staff training and the implementation of processes that provide guidance and documentation of the drug reconciliation process from admittance to discharge for safe patient passage through the various transitions of care. Recommendations to achieve optimal patient safety outcomes include the adoption and integration of available technologies with full functionality configured to meet the institution's policies and processes, initial training and retraining of all staff who use these systems, continuing education of the patient care staff on the dosing safety requirements, and assigning a prominent role to the clinical pharmacist in the entire drug-use and reconciliation process. The key factors contributing to inadvertent overdosage in inpatient settings include a lack of recognition of recommended maximum daily dosages; failure to optimally communicate medication information at transitions of care; failure to optimally implement medication safety technologies, particularly dose accumulator calculation features and associated alerts; and alert fatigue and override. Copyright © 2016 by the National Council for Prescription Drug Programs (NCPDP).

  11. Performance Assessment and Active System Monitoring for Refrigeration Systems

    DEFF Research Database (Denmark)

    Green, Torben

    for algorithms that ensures or improves the performance of the system. A supermarket refrigeration system is usually a complex and distributed control system, and it can therefore be difficult to assess the performance without a formal method. The main interest for a supermarket, with respect...... of the refrigeration system has been addressed in the project. The proposed methods for improvement relies on a minimum of detailed knowledge about the refrigeration system. In addition, since a refrigeration system often operates in steady state an active system monitoring setup has been proposed, to enable...... a method for assessing the operational performance at a plan-wide level and is therefore providing a tool for improving the plant-wide performance. The performance function has been used in dierent setups to improve the performance of the refrigeration system. Static and the dynamic performance...

  12. Development and Field Testing of a Multi- Antenna GPS System for Deformation Monitoring

    Institute of Scientific and Technical Information of China (English)

    Ding Xiao-li; Huang Ding-fa; Yin Jian-hua; Chen Yong-qi; C. K. Lau; Yang Yu-wen; Sun Yong-rong; Chen Wu; He Xiu-feng

    2003-01-01

    GPS has become an important technology for monitoring deformations of structures and the crust of the Earth. A limiting factor for large-scale use of GPS in such applications is however its high hardware cost. For automatic monitoring of deformations, each point to be monitored needs equipped with a set of GPS instruments. This makes many applications such as routine monitoring of landslides too expensive in most cases. A multi-antenna GPS system has been developed and tested aiming at significantly reducing the cost of GPS when used for monitoring deformations of objects such as slopes. The system uses special hardware and software to allow one GPS receiver to be used with a number of GPS antennas. One set of such equipment can therefore be used to monitor a number of points. The system normally reduces the cost of GPS hardware by a number of folds. Besides, such a system design also eases the tasks of data communication, management and system control. This paper describes the design and system configurations of the multi-antenna GPS system that has been developed by the research team. The system consists of integrated hardware and software components for data acquisition, transmission, processing, analysis and visualization. Integration of the GPS system with conventional slope monitoring systems will also be discussed in brief.

  13. Wireless Remote Monitoring System for Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Allan HUYNH

    2010-07-01

    Full Text Available Existing systems to collect temperature and relative humidity data at cultural heritage buildings require technical knowledge by people who are working with it, which is very seldom that they do have. The systems available today also require manual downloading of the collected data from the sensor to a computer for central storage and for further analysis. In this paper a wireless remote sensor network based on the ZigBee technology together with a simplified data collection system is presented. The system does not require any knowledge by the building administrator after the network is deployed. The wireless sensor device will automatically join available network when the user wants to expand the network. The collected data will be automatically and periodically synchronized to a remote main server via an Internet connection. The data can be used for centralized monitoring and other purpose. The power consumption of the sensor module is also minimized and the battery lifetime is estimated up to 10 years.

  14. How To Set Up a Workplace Mentoring System.

    Science.gov (United States)

    Wisconsin Univ., Madison. Center on Wisconsin Strategy.

    This document provides background for those looking to establish workplace mentoring or buddy systems. It touches briefly on the other two legs of an effective workplace preparation program, which are orientation and on-the-job training. These six steps for setting up a mentoring system are described: recruitment, flexibility, training, written…

  15. saltPAD: A New Analytical Tool for Monitoring Salt Iodization in Low Resource Settings

    Directory of Open Access Journals (Sweden)

    Nicholas M. Myers

    2016-03-01

    Full Text Available We created a paper test card that measures a common iodizing agent, iodate, in salt. To test the analytical metrics, usability, and robustness of the paper test card when it is used in low resource settings, the South African Medical Research Council and GroundWork performed independ‐ ent validation studies of the device. The accuracy and precision metrics from both studies were comparable. In the SAMRC study, more than 90% of the test results (n=1704 were correctly classified as corresponding to adequately or inadequately iodized salt. The cards are suitable for market and household surveys to determine whether salt is adequately iodized. Further development of the cards will improve their utility for monitoring salt iodization during production.

  16. Remote Monitoring System for Communication Base Based on Short Message

    Directory of Open Access Journals (Sweden)

    Han Yu Fu

    2013-07-01

    Full Text Available This paper presents design and development of an automatic monitoring system of communication base which is an important means to realize modernization of mobile communication base station management. Firstly, this paper proposes the architecture of the monitoring system. The proposed system consists of mocrocontrollers, sensors, GSM module and MFRC500 etc. The value of parameters is measured in the system including terminal is studied and designed, including hardware design based on embedded system and software design. Finally, communication module is discussed. The monitoring system which is designed  based on GSM SMS(short message service can improve the integrity, reliability, flexibility and intellectuality of monitoring system.

  17. An integrated, open-source set of tools for urban vulnerability monitoring from Earth observation data

    Science.gov (United States)

    De Vecchi, Daniele; Harb, Mostapha; Dell'Acqua, Fabio; Aurelio Galeazzo, Daniel

    2015-04-01

    Aim: The paper introduces an integrated set of open-source tools designed to process medium and high-resolution imagery with the aim to extract vulnerability indicators [1]. Problem: In the context of risk monitoring [2], a series of vulnerability proxies can be defined, such as the extension of a built-up area or buildings regularity [3]. Different open-source C and Python libraries are already available for image processing and geospatial information (e.g. OrfeoToolbox, OpenCV and GDAL). They include basic processing tools but not vulnerability-oriented workflows. Therefore, it is of significant importance to provide end-users with a set of tools capable to return information at a higher level. Solution: The proposed set of python algorithms is a combination of low-level image processing and geospatial information handling tools along with high-level workflows. In particular, two main products are released under the GPL license: source code, developers-oriented, and a QGIS plugin. These tools were produced within the SENSUM project framework (ended December 2014) where the main focus was on earthquake and landslide risk. Further development and maintenance is guaranteed by the decision to include them in the platform designed within the FP 7 RASOR project . Conclusion: With the lack of a unified software suite for vulnerability indicators extraction, the proposed solution can provide inputs for already available models like the Global Earthquake Model. The inclusion of the proposed set of algorithms within the RASOR platforms can guarantee support and enlarge the community of end-users. Keywords: Vulnerability monitoring, remote sensing, optical imagery, open-source software tools References [1] M. Harb, D. De Vecchi, F. Dell'Acqua, "Remote sensing-based vulnerability proxies in the EU FP7 project SENSUM", Symposium on earthquake and landslide risk in Central Asia and Caucasus: exploiting remote sensing and geo-spatial information management, 29-30th January 2014

  18. Standard-D hydrogen monitoring system, system design description

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1996-09-26

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS.

  19. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2740 Perinatal monitoring system and accessories. (a) Identification. A...

  20. Setting Priorities for Monitoring and Managing Non-native Plants: Toward a Practical Approach

    Science.gov (United States)

    Koch, Christiane; Jeschke, Jonathan M.; Overbeck, Gerhard E.; Kollmann, Johannes

    2016-09-01

    Land managers face the challenge to set priorities in monitoring and managing non-native plant species, as resources are limited and not all non-natives become invasive. Existing frameworks that have been proposed to rank non-native species require extensive information on their distribution, abundance, and impact. This information is difficult to obtain and often not available for many species and regions. National watch or priority lists are helpful, but it is questionable whether they provide sufficient information for environmental management on a regional scale. We therefore propose a decision tree that ranks species based on more simple albeit robust information, but still provides reliable management recommendations. To test the decision tree, we collected and evaluated distribution data from non-native plants in highland grasslands of Southern Brazil. We compared the results with a national list from the Brazilian Invasive Species Database for the state to discuss advantages and disadvantages of the different approaches on a regional scale. Out of 38 non-native species found, only four were also present on the national list. If management would solely rely on this list, many species that were identified as spreading based on the decision tree would go unnoticed. With the suggested scheme, it is possible to assign species to active management, to monitoring, or further evaluation. While national lists are certainly important, management on a regional scale should employ additional tools that adequately consider the actual risk of non-natives to become invasive.

  1. Network-Oriented Radiation Monitoring System (NORMS)

    Energy Technology Data Exchange (ETDEWEB)

    Rahmat Aryaeinejad; David F. Spencer

    2007-10-01

    We have developed a multi-functional pocket radiation monitoring system capable of detecting and storing gamma ray and neutron data and then sending the data through a wireless connection to a remote central facility upon request. The device has programmable alarm trigger levels that can be modified for specific applications. The device could be used as a stand-alone device or in conjunction with an array to cover a small or large area. The data is stored with a date/time stamp. The device may be remotely configured. Data can be transferred and viewed on a PDA via direct connection or wirelessly. Functional/bench tests have been completed successfully. The device detects low-level neutron and gamma sources within a shielded container in a radiation field of 10 uR/hr above the ambient background level.

  2. Factorial switching linear dynamical systems applied to physiological condition monitoring.

    Science.gov (United States)

    Quinn, John A; Williams, Christopher K I; McIntosh, Neil

    2009-09-01

    Condition monitoring often involves the analysis of systems with hidden factors that switch between different modes of operation in some way. Given a sequence of observations, the task is to infer the filtering distribution of the switch setting at each time step. In this paper, we present factorial switching linear dynamical systems as a general framework for handling such problems. We show how domain knowledge and learning can be successfully combined in this framework, and introduce a new factor (the "X-factor") for dealing with unmodeled variation. We demonstrate the flexibility of this type of model by applying it to the problem of monitoring the condition of a premature baby receiving intensive care. The state of health of a baby cannot be observed directly, but different underlying factors are associated with particular patterns of physiological measurements and artifacts. We have explicit knowledge of common factors and use the X-factor to model novel patterns which are clinically significant but have unknown cause. Experimental results are given which show the developed methods to be effective on typical intensive care unit monitoring data.

  3. Computer system for monitoring power boiler operation

    Energy Technology Data Exchange (ETDEWEB)

    Taler, J.; Weglowski, B.; Zima, W.; Duda, P.; Gradziel, S.; Sobota, T.; Cebula, A.; Taler, D. [Cracow University of Technology, Krakow (Poland). Inst. for Process & Power Engineering

    2008-02-15

    The computer-based boiler performance monitoring system was developed to perform thermal-hydraulic computations of the boiler working parameters in an on-line mode. Measurements of temperatures, heat flux, pressures, mass flowrates, and gas analysis data were used to perform the heat transfer analysis in the evaporator, furnace, and convection pass. A new construction technique of heat flux tubes for determining heat flux absorbed by membrane water-walls is also presented. The current paper presents the results of heat flux measurement in coal-fired steam boilers. During changes of the boiler load, the necessary natural water circulation cannot be exceeded. A rapid increase of pressure may cause fading of the boiling process in water-wall tubes, whereas a rapid decrease of pressure leads to water boiling in all elements of the boiler's evaporator - water-wall tubes and downcomers. Both cases can cause flow stagnation in the water circulation leading to pipe cracking. Two flowmeters were assembled on central downcomers, and an investigation of natural water circulation in an OP-210 boiler was carried out. On the basis of these measurements, the maximum rates of pressure change in the boiler evaporator were determined. The on-line computation of the conditions in the combustion chamber allows for real-time determination of the heat flowrate transferred to the power boiler evaporator. Furthermore, with a quantitative indication of surface cleanliness, selective sootblowing can be directed at specific problem areas. A boiler monitoring system is also incorporated to provide details of changes in boiler efficiency and operating conditions following sootblowing, so that the effects of a particular sootblowing sequence can be analysed and optimized at a later stage.

  4. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based quest

  5. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based quest

  6. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  7. [The research and expectation on wearable health monitoring system].

    Science.gov (United States)

    Chang, Feiba; Yin, Jun; Zhang, Hehua; Yan, Lexian; Li, Shuying; Zhou, Deqiang

    2015-01-01

    Wearable health monitoring systems that use wearable biosensors capturing human motion and physiological parameters, to achieve the wearer's movement and health management needs. Wearable health monitoring system is a noninvasive continuous detection of human physiological information, data wireless transmission and real-time processing capabilities of integrated system, can satisfy physiological condition monitoring under the condition of low physiological and psychological load. This paper first describes the wearable health monitoring system structure and the relevant technology applied to wearable health monitoring system, and focuses on the current research work what we have done associated with wearable monitoring that wearable respiration and ECG acquisition and construction of electric multi-parameter body area network. Finally, the wearable monitoring system for the future development direction is put forward a simple expectation.

  8. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  9. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  10. Monitoring System with Two Central Facilities Protocol

    Directory of Open Access Journals (Sweden)

    Caesar Firdaus

    2017-03-01

    Full Text Available The security of data and information on government’s information system required proper way of defending against threat. Security aspect can be achieved by using cryptography algorithm, applying information hiding concept, and implementing security protocol. In this research, two central facilities protocol was implemented on Research and Development Center of Mineral and Coal Technology’s Cooperation Contract Monitoring System by utilizing AES and whitespace manipulation algorithm. Adjustment on the protocol by creating several rule of validation ID’s generation and checking processes could fulfill two of four cryptography objectives, consist of authentication and non-repudiation. The solid collaboration between central legitimization agency (CLA, central tabulating facility (CTF, and client is the main idea in two central facilities protocol. The utilization of AES algorithm could defend the data on transmission from man in the middle attack scenario. On the other hand, whitespace manipulation algorithm provided data integrity aspect of the document that is uploaded to the system itself. Both of the algorithm fulfill confidentiality, data integrity, and authentication.

  11. Involutive characteristic sets of algebraic partial differential equation systems

    Institute of Scientific and Technical Information of China (English)

    陈玉福; 高小山

    2003-01-01

    This paper presents an algorithm to reduce a nonlinear algebraic partial differential equation system into the involutive characteristic set with respect to an abstract involutive prolongation direction, which covers the existing algorithms based on Riquier method, Thomas method, and Pommaret method. It also provides new algorithms for computing involutive characteristic sets due to the existence of new involutive directions. Experiments show that these new algorithms may be used to significantly reduce the computational steps in Wu-Ritt's characteristic set method for algebraic partial differential equations.

  12. Advanced Systems for Monitoring Underwater Sounds

    Science.gov (United States)

    Lane, Michael; Van Meter, Steven; Gilmore, Richard Grant; Sommer, Keith

    2007-01-01

    The term "Passive Acoustic Monitoring System" (PAMS) describes a developmental sensing-and-data-acquisition system for recording underwater sounds. The sounds (more precisely, digitized and preprocessed versions from acoustic transducers) are subsequently analyzed by a combination of data processing and interpretation to identify and/or, in some cases, to locate the sources of those sounds. PAMS was originally designed to locate the sources such as fish of species that one knows or seeks to identify. The PAMS unit could also be used to locate other sources, for example, marine life, human divers, and/or vessels. The underlying principles of passive acoustic sensing and analyzing acoustic-signal data in conjunction with temperature and salinity data are not new and not unique to PAMS. Part of the uniqueness of the PAMS design is that it is the first deep-sea instrumentation design to provide a capability for studying soniferous marine animals (especially fish) over the wide depth range described below. The uniqueness of PAMS also lies partly in a synergistic combination of advanced sensing, packaging, and data-processing design features with features adapted from proven marine instrumentation systems. This combination affords a versatility that enables adaptation to a variety of undersea missions using a variety of sensors. The interpretation of acoustic data can include visual inspection of power-spectrum plots for identification of spectral signatures of known biological species or artificial sources. Alternatively or in addition, data analysis could include determination of relative times of arrival of signals at different acoustic sensors arrayed at known locations. From these times of arrival, locations of acoustic sources (and errors in those locations) can be estimated. Estimates of relative locations of sources and sensors can be refined through analysis of the attenuation of sound in the intervening water in combination with water-temperature and salinity

  13. Field surveys of carbon monoxide in commercial settings using personal exposure monitors

    Science.gov (United States)

    Flachsbart, P. G.; Ott, W. R.

    1984-02-01

    Miniaturized personal exposure monitors (PEMs) were employed to measure carbon monoxide (CO) in 588 different commercial settings (e.g., retail stores, office buildings, hotels, restaurants) in five California cities. Altogether, 5000 CO observations were made by recording the instantaneous instrument reading at 1-minute intervals as the investigators walked along sidewalks and into buildings. For 11 of 15 survey dates, two investigators walked side-by-side, permitting two adjacent PEMs to be compared. Quality assurance tests for 1706 pairs of values showed a very high degree of agreement. CO levels for indoor commercial settings were similar to those measured outdoors on sidewalks, apparently because the pollutant seeps into the structures from traffic outside. Although indoor levels usually were above 0 ppm, they seldom were above 9 ppm (the National Ambient Air Quality Standard for an 8-hour exposure), unless some indoor source could be identified. Carbon monoxide levels on outdoor streets did not vary greatly on different sides of the street, on corners and faces of blocks, and intersections.

  14. 4D inversion of time-lapse magnetotelluric data sets for monitoring geothermal reservoir

    Science.gov (United States)

    Nam, Myung Jin; Song, Yoonho; Jang, Hannuree; Kim, Bitnarae

    2017-06-01

    The productivity of a geothermal reservoir, which is a function of the pore-space and fluid-flow path of the reservoir, varies since the properties of the reservoir changes with geothermal reservoir production. Because the variation in the reservoir properties causes changes in electrical resistivity, time-lapse (TL) three-dimensional (3D) magnetotelluric (MT) methods can be applied to monitor the productivity variation of a geothermal reservoir thanks to not only its sensitivity to the electrical resistivity but also its deep depth of survey penetration. For an accurate interpretation of TL MT-data sets, a four-dimensional (4D) MT inversion algorithm has been developed to simultaneously invert all vintage data considering time-coupling between vintages. However, the changes in electrical resistivity of deep geothermal reservoirs are usually small generating minimum variation in TL MT responses. Maximizing the sensitivity of inversion to the changes in resistivity is critical in the success of 4D MT inversion. Thus, we further developed a focused 4D MT inversion method by considering not only the location of a reservoir but also the distribution of newly-generated fractures during the production. For the evaluation of the 4D MT algorithm, we tested our 4D inversion algorithms using synthetic TL MT-data sets.

  15. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  16. Application of Aquaculture Monitoring System Based on CC2530

    Science.gov (United States)

    Chen, H. L.; Liu, X. Q.

    In order to improve the intelligent level of aquaculture technology, this paper puts forward a remote wireless monitoring system based on ZigBee technology, GPRS technology and Android mobile phone platform. The system is composed of wireless sensor network (WSN), GPRS module, PC server, and Android client. The WSN was set up by CC2530 chips based on ZigBee protocol, to realize the collection of water quality parameters such as the water level, temperature, PH and dissolved oxygen. The GPRS module realizes remote communication between WSN and PC server. Android client communicates with server to monitor the level of water quality. The PID (proportion, integration, differentiation) control is adopted in the control part, the control commands from the android mobile phone is sent to the server, the server again send it to the lower machine to control the water level regulating valve and increasing oxygen pump. After practical testing to the system in Liyang, Jiangsu province, China, temperature measurement accuracy reaches 0.5°C, PH measurement accuracy reaches 0.3, water level control precision can be controlled within ± 3cm, dissolved oxygen control precision can be controlled within ±0.3 mg/L, all the indexes can meet the requirements, this system is very suitable for aquaculture.

  17. Multiplexed FBG Monitoring System for Forecasting Coalmine Water Inrush Disaster

    Directory of Open Access Journals (Sweden)

    B. Liu

    2012-01-01

    Full Text Available This paper presents a novel fiber-Bragg-grating- (FBG- based system which can monitor and analyze multiple parameters such as temperature, strain, displacement, and seepage pressure simultaneously for forecasting coalmine water inrush disaster. The sensors have minimum perturbation on the strain field. And the seepage pressure sensors adopt a drawbar structure and employ a corrugated diaphragm to transmit seepage pressure to the axial strain of FBG. The pressure sensitivity is 20.20 pm/KPa, which is 6E3 times higher than that of ordinary bare FBG. The FBG sensors are all preembedded on the roof of mining area in coalmine water inrush model test. Then FBG sensing network is set up applying wavelength-division multiplexing (WDM technology. The experiment is carried out by twelve steps, while the system acquires temperature, strain, displacement, and seepage pressure signals in real time. The results show that strain, displacement, and seepage pressure monitored by the system change significantly before water inrush occurs, and the strain changes firstly. Through signal fusion analyzed it can be concluded that the system provides a novel way to forecast water inrush disaster successfully.

  18. Developing GP monitoring systems guided by a soft systems approach.

    Science.gov (United States)

    Hindle, T

    1995-11-01

    This paper describes a selected aspect of a research project concerned with 'contracts and competition' in the recently reformed National Health Service. The particular feature highlighted in this paper is the central role played by the general practitioners in the health service as principal sources of the demands made on provider units (particularly hospitals) and, hence, critical determinants of volumes and costs in contracting. A practical outcome of the research has been the development of GP monitoring systems to be used by provider units particularly in the context of marketing-led referral expectations. The approach used to highlight areas of potential GP contract management and monitoring improvements has been a development of soft systems methodology.

  19. AOIPS data base management systems support for GARP data sets

    Science.gov (United States)

    Gary, J. P.

    1977-01-01

    A data base management system is identified, developed to provide flexible access to data sets produced by GARP during its data systems tests. The content and coverage of the data base are defined and a computer-aided, interactive information storage and retrieval system, implemented to facilitate access to user specified data subsets, is described. The computer programs developed to provide the capability were implemented on the highly interactive, minicomputer-based AOIPS and are referred to as the data retrieval system (DRS). Implemented as a user interactive but menu guided system, the DRS permits users to inventory the data tape library and create duplicate or subset data sets based on a user selected window defined by time and latitude/longitude boundaries. The DRS permits users to select, display, or produce formatted hard copy of individual data items contained within the data records.

  20. Optimal Set-Point Synthesis in HVAC Systems

    DEFF Research Database (Denmark)

    Komareji, Mohammad; Stoustrup, Jakob; Rasmussen, Henrik

    2007-01-01

    components, encompassing fans, primary/secondary pump, tertiary pump, and air-to-air heat exchanger wheel; and a fraction of thermal power used by the HVAC system. The goals that have to be achieved by the HVAC system appear as constraints in the optimization problem. To solve the optimization problem......This paper presents optimal set-point synthesis for a heating, ventilating, and air-conditioning (HVAC) system. This HVAC system is made of two heat exchangers: an air-to-air heat exchanger and a water-to-air heat exchanger. The objective function is composed of the electrical power for different......, a steady state model of the HVAC system is derived while different supplying hydronic circuits are studied for the water-to-air heat exchanger. Finally, the optimal set-points and the optimal supplying hydronic circuit are resulted....

  1. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  2. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  3. Design of CMS Beam Halo Monitor system

    CERN Document Server

    AUTHOR|(CDS)2078842

    2015-01-01

    A fast and directional monitoring system for the CMS experiment is designed to provide an online, bunch-by-bunch measurement of beam background induced by beam halo interactions, separately for each beam. The background detection is based on Cherenkov radiation produced in synthetic fused silica read out by a fast, UV sensitive photomultiplier tube. Twenty detector units per end will be azimuthally distributed around the rotating shielding of CMS, covering ~408 cm2 at 20.6m from the interaction point, at a radius of ~180 cm. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. A robust multi-layered shielding will enclose each detector unit to protect the photomultiplier tube from the magnetic field and to eliminate the occupancy from low energy particles. The design of the front-end units is validated by experimental results. An overview of the new sy...

  4. Survey of remote data monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Logee, T.L.; Kendall, P.W.; Pollock, E.O.; Raymond, M.G.; Knapp, R.C. Jr.

    1984-09-01

    A self-contained data-logger device called an SDAS (Site Data Acquisition Subsystem) was built for the National Solar Data Network (NSDN) which could collect analog data from 96 channels, store the data for up to three days, and then transmit the stored data on request to a central facility by voice-grade telephone lines. This system has worked fairly well for the eight years that it has been in service. However, the design and components are getting old and newer dataloggers may be more reliable and accurate and less expensive. This report discusses the results of an extensive search for an SDAS replacement. The survey covered 62 models from 36 manufacturers. These numbers are not indicative of all the dataloggers or manufacturers available, but only those which appeared to have some qualifications for the NSDN datalogger replacement. This report views the datalogger as a system which is made up of sensors, a data acquisition and storage unit, a telecommunications subsystem, and a data processing subsystem. Therefore, there is a section on sensors used in the NSDN, telecommunications technology, and data processing requirements. These four components or subsystems are all necessary in order to have an integrated, successful remote data monitoring network.

  5. GuMNet - Guadarrama Monitoring Network. Installation and set up of a high altitude monitoring network, north of Madrid. Spain

    Science.gov (United States)

    Santolaria-Canales, Edmundo

    2015-04-01

    An observational monitoring network in the Guadarrama Mountains is due to be operational at the end of 2015. This network integrates atmospheric measurements as well as subsurface observations in a high mountain climate, located up to 2.400 m.a.s.l. The data provided by GuMNet will help to improve the characterization of microclimate in high mountain areas, as well as land-atmosphere interations. The network information aims at meeting the needs of accuracy to be used for biological, agricultural, hydrological, meteorological and climatic investigations in this area. This initiative is supported and developed by research groups integrating the GuMNet Consortiuma from the Complutense and Polytechnical Universities of Madrid (UCM and UPM), the Energetic Environmental and Technological Research Centre (CIEMAT), the Spanish National Meteorological Agency (AEMET), and the National Park Sierra de Guadarrama (PNSG). The starting setup includes seven meteorological stations compatible with WMO standards, to be installed in the central area of the massif. Including a four-component net radiation sensor, an ultrasonic snow height, a pluviometer specialized for snow capture, air temperature and humidity devices and wind speed/direction sensor. Along with these atmospheric measurements, each station will include a set of subsurface measurements of temperature in shallow boreholes ( 20 m depth ) and temperature and humidity in trenches up to 1 m depth. These compatible WMO stations will be complemented by a station specialized in eddy covariance measuremets with CO2 fluxes at low altitude pastureland near Madrid. Another portable station is available to develop ad hoc comparison studies. This setup is embedded in a broader network of meteorological stations run partly by AEMET and partly by the PNSG. Most of the AEMET stations are distributed over lower altitudes, and will provide a very reliable boundary information for the atmosphere state around the Sierra. In the same way

  6. Conditions for Set Agreement with an Application to Synchronous Systems

    Institute of Scientific and Technical Information of China (English)

    Francois Bonnet; Michel Raynal

    2009-01-01

    The k-set agreement problem is a generalization of the consensus problem: considering a system made up of n processes where each process proposes a value, each non-faulty process has to decide a value such that a decided value is a proposed value, and no more than k different values are decided. While this problem cannot be solved in an asynchronous system prone to t process crashes when t ≥k, it can always be solved in a synchronous system; [t/k]+ 1 is then a lower bound on the number of rounds (consecutive communication steps) for the non-faulty processes to decide. The condition-based approach has been introduced in the consensus context. Its aim was to both circumvent the consensus impossibility in asynchronous systems, and allow for more efficient consensus algorithms in synchronous systems. This paper addresses the condition-based approach in the context of the k-set agreement problem. It has two main contributions. The first is the definition of a framework that allows defining conditions suited to the l-set agreement problem and the second is a generic synchronous k-set agreement algorithm based on conditions.

  7. Bridging knowledge systems to enhance governance of environmental commons: A typology of settings

    Directory of Open Access Journals (Sweden)

    Kaitlyn Joanne Rathwell

    2015-09-01

    Full Text Available We offer a typology of settings to bridge scientific and indigenous knowledge systems and to enhance governance of the environmental commons in contexts of change.  We contribute to a need for further clarity on how to incorporate diverse knowledge systems and in ways that contribute to planning, management, monitoring and assessment from local to global levels. We ask, what settings are discussed in the resource and environmental governance literature to support efforts to bridge indigenous and scientific knowledge systems? The objectives are: 1 to offer a typology that organizes various settings to bridge knowledge systems; and 2 to elaborate on how these settings function independently and in concert, using examples from a diverse literature in addition to field research experience. Our focus is on indigenous and scientific knowledge, but the typology offers lessons to bridge diverse knowledge systems more generally, and in ways that are sensitive to a moral, political and process-based approach. The typology includes specific methods and processes, brokering strategies, governance and institutional contexts, and the arena of epistemology. We describe each setting in the typology, and provide examples to reflect on the function and potential outcomes of different settings. Insights from our synthesis can inform policy and participatory action.

  8. Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC

    CERN Document Server

    Abbrescia, M; Guida, R; Iaselli, G; Liuzzi, R; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pugliese, G; Ranieri, A; Romano, F; Trentadue, R; Benussi, L; Bertani, M; Bianco, S; Caponero, M A; Colonna, D; Donisi, D; Fabbri, F L; Felli, F; Ortenzi, M G B; Pallotta, M; Paolozzi, A; Passamonti, L; Ponzio, B; Pucci, C; Polese, G S G; Segoni, I; Cavallo, N; Fabozzi, F; Paolucci, P; Piccolo, D; Belli, C S G; Grelli, A; Necchi, M; Ratti, S P; Riccardi, C; Torre, P; Vitulo, P

    2006-01-01

    The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.

  9. Our Solar System. Our Solar System Topic Set

    Science.gov (United States)

    Phelan, Glen

    2006-01-01

    This book examines the planets and other objects in space that make up the solar system. It also shows how technology helps students learn about our neighbors in space. The suggested age range for this book is 3-8 with a guided reading level of Q-R. The Fry level is 3.2.

  10. Our Solar System. Our Solar System Topic Set

    Science.gov (United States)

    Phelan, Glen

    2006-01-01

    This book examines the planets and other objects in space that make up the solar system. It also shows how technology helps students learn about our neighbors in space. The suggested age range for this book is 3-8 with a guided reading level of Q-R. The Fry level is 3.2.

  11. Cerebral microdialysis for protein biomarker monitoring in the neurointensive care setting

    Directory of Open Access Journals (Sweden)

    Lars Tomas Hillered

    2014-12-01

    Full Text Available Cerebral microdialysis (MD was introduced as a neurochemical monitoring tool in the early 1990s and is currently well established for the sampling of low molecular weight biomarkers of energy metabolic perturbation and cellular distress in the neurointensive care (NIC setting. There is now a growing interest in MD for intracerebral sampling of protein biomarkers of secondary injury mechanisms in acute traumatic and neurovascular brain injury in the NIC community. The initial enthusiasm over the opportunity to sample protein biomarkers with high molecular weight cut-off (MWCO MD catheters has dampened somewhat with the emerging realization of inherent problems with this methodology including protein adhesion, protein-protein interaction and biofouling, leading to unstable MD catheter performance (i.e. fluid recovery and extraction efficiency. This review will focus on the results of a multidisciplinary collaborative effort, within the Uppsala Berzelii Centre for Neurodiagnostics during the past several years, to study the features of the complex process of high MWCO MD for protein biomarkers. This research has led to new methodology showing robust in vivo performance with optimized fluid recovery and improved extraction efficiency, allowing for more accurate biomarker monitoring. In combination with evolving analytical methodology allowing for multiplex biomarker analysis in ultra-small MD samples a new opportunity opens up for high-resolution temporal mapping of secondary injury cascades, such as neuroinflammation and other cell injury reactions directly in the injured human brain. Such data may provide an important basis for improved characterization of complex injuries, e.g. traumatic and neurovascular brain injury, and help in defining targets and treatment windows for neuroprotective drug development

  12. Electronic Health Monitoring for Space Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Prognostic monitoring capabilities for space exploration aircrafts are crucial to enable safety and reliability in these platforms. Nokomis proposes to develop and...

  13. Numerical Construction of Viable Sets for Autonomous Conflict Control Systems

    Directory of Open Access Journals (Sweden)

    Nikolai Botkin

    2014-04-01

    Full Text Available A conflict control system with state constraints is under consideration. A method for finding viability kernels (the largest subsets of state constraints where the system can be confined is proposed. The method is related to differential games theory essentially developed by N. N. Krasovskii and A. I. Subbotin. The viability kernel is constructed as the limit of sets generated by a Pontryagin-like backward procedure. This method is implemented in the framework of a level set technique based on the computation of limiting viscosity solutions of an appropriate Hamilton–Jacobi equation. To fulfill this, the authors adapt their numerical methods formerly developed for solving time-dependent Hamilton–Jacobi equations arising from problems with state constraints. Examples of computing viability sets are given.

  14. Digital controlling system to the set of high power LEDs

    Science.gov (United States)

    Gilewski, Marian; Gryko, Lukasz; Zajac, Andrzej

    2013-07-01

    In the paper is described the concept and architecture of the multi-channel control system for set of high-power LEDs. The broadband source of radiation for prototype illuminator is dedicated to the investigation of Low Level Laser Therapy procedures. The general scheme of the system, detailed schemes, control algorithm and its implementation description in FPGA structure is presented. The temperature conditions and the opportunity to work with a microcomputer are characterized.

  15. 40 CFR 257.22 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... operator. When physical obstacles preclude installation of ground-water monitoring wells at the relevant... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water......

  16. 40 CFR 258.51 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... preclude installation of ground-water monitoring wells at the relevant point of compliance at existing... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51...

  17. Review on Environment Monitoring System and Energy Efficiency

    Directory of Open Access Journals (Sweden)

    Nikita Gaikwad

    2015-07-01

    Full Text Available The Environment monitoring is one of the applications of wireless sensor network. The most serious environment pollution is air pollution because different air pollutant causes damage to human health and causes global warming. To avoid such effect on human health and climate change Environment monitoring systems are used. This paper provides the short overview of different environmental air pollution monitoring systems and Energy efficiency in WSN to reduced the power consumption of system.

  18. Hydrological Monitoring System Design and Implementation Based on IOT

    Science.gov (United States)

    Han, Kun; Zhang, Dacheng; Bo, Jingyi; Zhang, Zhiguang

    In this article, an embedded system development platform based on GSM communication is proposed. Through its application in hydrology monitoring management, the author makes discussion about communication reliability and lightning protection, suggests detail solutions, and also analyzes design and realization of upper computer software. Finally, communication program is given. Hydrology monitoring system from wireless communication network is a typical practical application of embedded system, which has realized intelligence, modernization, high-efficiency and networking of hydrology monitoring management.

  19. Design Scheme of Remote Monitoring System Based on Qt

    Directory of Open Access Journals (Sweden)

    Xu Dawei

    2015-01-01

    Full Text Available This paper introduces a design scheme of remote monitoring system based on Qt, the scheme of remote monitoring system based on S3C2410 and Qt, with the aid of cross platform development tools Qt and powerful ARM platform design and implementation. The development of remote video surveillance system based on embedded terminal has practical significance and value.

  20. 78 FR 11090 - Steel Import Monitoring and Analysis System

    Science.gov (United States)

    2013-02-15

    ... International Trade Administration 19 CFR Part 360 RIN 0625-AA93 Steel Import Monitoring and Analysis System... to extend the Steel Import Monitoring and Analysis (SIMA) system until March 21, 2017. The purpose of the SIMA system is to provide the public statistical data on steel imports entering the United...

  1. 47 CFR 73.68 - Sampling systems for antenna monitors.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Sampling systems for antenna monitors. 73.68... RADIO BROADCAST SERVICES AM Broadcast Stations § 73.68 Sampling systems for antenna monitors. (a) Each AM station permittee authorized to construct a new directional antenna system which will be...

  2. An advanced condition monitoring system for turbopumps

    Science.gov (United States)

    Cross, George S.; Barkhoudarian, Sarkis

    1991-01-01

    Advanced condition monitoring (ACM) technologies developed for in situ turbomachinery applications are reviewed. The ACM concepts are based on direct in situ hardware monitoring and between-flight inspections, using novel real-time, automated, noncontacting, and nonintrusive sensor and associated electronic technologies.

  3. A New Model of Delirium Care in the Acute Geriatric Setting: Geriatric Monitoring Unit

    Directory of Open Access Journals (Sweden)

    Chong Mei

    2011-08-01

    Full Text Available Abstract Background Delirium is a common and serious condition, which affects many of our older hospitalised patients. It is an indicator of severe underlying illness and requires early diagnosis and prompt treatment, associated with poor survival, functional outcomes with increased risk of institutionalisation following the delirium episode in the acute care setting. We describe a new model of delirium care in the acute care setting, titled Geriatric Monitoring Unit (GMU where the important concepts of delirium prevention and management are integrated. We hypothesize that patients with delirium admitted to the GMU would have better clinical outcomes with less need for physical and psychotropic restraints compared to usual care. Methods/Design GMU models after the Delirium Room with adoption of core interventions from Hospital Elder Life Program and use of evening bright light therapy to consolidate circadian rhythm and improve sleep in the elderly patients. The novelty of this approach lies in the amalgamation of these interventions in a multi-faceted approach in acute delirium management. GMU development thus consists of key considerations for room design and resource planning, program specific interventions and daily core interventions. Assessments undertaken include baseline demographics, comorbidity scoring, duration and severity of delirium, cognitive, functional measures at baseline, 6 months and 12 months later. Additionally we also analysed the pre and post-GMU implementation knowledge and attitude on delirium care among staff members in the geriatric wards (nurses, doctors and undertook satisfaction surveys for caregivers of patients treated in GMU. Discussion This study protocol describes the conceptualization and implementation of a specialized unit for delirium management. We hypothesize that such a model of care will not only result in better clinical outcomes for the elderly patient with delirium compared to usual geriatric care

  4. Optical monitoring system for a turbine engine

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, Dennis H; Smed, Jan P; Williams, James P; Jonnalagadda, Vinay

    2013-05-14

    The monitoring system for a gas turbine engine including a viewing tube assembly having an inner end and an outer end. The inner end is located adjacent to a hot gas flow path within the gas turbine engine and the outer end is located adjacent to an outer casing of the gas turbine engine. An aperture wall is located at the inner end of the viewing tube assembly and an optical element is located within the viewing tube assembly adjacent to the inner end and is spaced from the aperture wall to define a cooling and purge chamber therebetween. An aperture is defined in the aperture wall for passage of light from the hot gas flow path to the optical element. Swirl passages are defined in the viewing tube assembly between the aperture wall and the optical element for passage of cooling air from a location outside the viewing tube assembly into the chamber, wherein swirl passages effect a swirling movement of air in a circumferential direction within the chamber.

  5. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  6. Priority setting and health policy and systems research

    Directory of Open Access Journals (Sweden)

    Bennett Sara C

    2009-12-01

    Full Text Available Abstract Health policy and systems research (HPSR has been identified as critical to scaling-up interventions to achieve the millennium development goals, but research priority setting exercises often do not address HPSR well. This paper aims to (i assess current priority setting methods and the extent to which they adequately include HPSR and (ii draw lessons regarding how HPSR priority setting can be enhanced to promote relevant HPSR, and to strengthen developing country leadership of research agendas. Priority setting processes can be distinguished by the level at which they occur, their degree of comprehensiveness in terms of the topic addressed, the balance between technical versus interpretive approaches and the stakeholders involved. When HPSR is considered through technical, disease-driven priority setting processes it is systematically under-valued. More successful approaches for considering HPSR are typically nationally-driven, interpretive and engage a range of stakeholders. There is still a need however for better defined approaches to enable research funders to determine the relative weight to assign to disease specific research versus HPSR and other forms of cross-cutting health research. While country-level research priority setting is key, there is likely to be a continued need for the identification of global research priorities for HPSR. The paper argues that such global priorities can and should be driven by country level priorities.

  7. Monitoring system for the quality assessment in additive manufacturing

    Science.gov (United States)

    Carl, Volker

    2015-03-01

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality

  8. Monitoring system for the quality assessment in additive manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Carl, Volker, E-mail: carl@t-zfp.de [Carl Messtechnik, Thyssenstrasse 183a, 46535 Dinslaken (Germany)

    2015-03-31

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality

  9. Application of a microseismic monitoring system in deep mining

    Institute of Scientific and Technical Information of China (English)

    Chengxiang Yang; Zhouquan Luo; Guobin Hu; Xiaoming Liu

    2007-01-01

    A microseismic monitoring system was used in the Donggua Shan underground copper mine,and its application was introduced.The spacial distribution of the seismic event was monitored effectively during mining with this system.The distribution of the seismic intensity in different time periods and in the different mining districts was obtained via the clustering analysis of the monitored results,and the different intensity concentration districts of seismicity were compartmentalized.The various characteristics and waveforms of different vibrations in the underground mine were revealed with the help of the micro-seismic monitoring system.It was proved that the construction and application of the micro-seismic monitoring system in the mine not only realized the continuous monitoring of seismicity in the deep mine,but also settled an important foundation for further studies on hazard prediction,based on this system.

  10. Automatic video monitoring system for assessment of Alzheimer's disease symptoms.

    Science.gov (United States)

    Romdhane, R; Mulin, E; Derreumeaux, A; Zouba, N; Piano, J; Lee, L; Leroi, I; Mallea, P; David, R; Thonnat, M; Bremond, F; Robert, P H

    2012-03-01

    In order to fully capture the complexity of the behavioural, functioning and cognitive disturbances in Alzheimer Disease (AD) and related disorders information and communication techniques (ICT), could be of interest. This article presents using 3 clinical cases the feasibility results of an automatic video monitoring system aiming to assess subjects involved in a clinical scenario. The study was conducted in an observation room equipped with everyday objects for use in activities of daily living. The overall aim of the clinical scenario was to enable the participants to undertake a set of daily tasks that could realistically be achieved in the setting of the observation room. The scenario was divided in three steps covering basic to more complex activities: (1) Directed activities, (2) Semi-directed activities, (3) Undirected ("free") activities. The assessment of each participant of the study was done with an automatic video monitoring system composed of a vision component and an event recognition component. The feasibility study involved three participants: two AD patients and one elderly control participant. The first result of the study was to demonstrate the feasibility of this new assessment method from both the patient and the technical points of view. During the first step the control participant performed all these activities faster than the two AD participants. During the second step of the scenario AD participants were not able to follow the correct order of the tasks and even omitted some of them. Finally during the last step of the scenario devoted to free activities the control participant chose one of the proposed activities (reading) and undertook this activity for almost the entire duration. In contrast, the two AD participants had more difficulties choosing one of the suggested activities and were not able to undertake any one activity in a sustained manner. The automatic video monitoring system presented here analyzes human behaviours and looks

  11. Online Monitor Framework for Network Distributed Data Acquisition Systems

    Science.gov (United States)

    Konno, Tomoyuki; Cabrera, Anatael; Ishitsuka, Masaki; Kuze, Masahiro; Sakamoto, Yasunobu; the Double Chooz Collaboration

    Data acquisition (DAQ) systems for recent high energy physics experiments consist of lots of subsystems distributed in the local area network. Therefore, scalability for the number of connections from subsystems and availability of access via the Internet are required. "Online monitor framework" is a general software framework for online data monitoring, which provides a way to collect monitoring information distributed in the network and pass them though the firewalls. The framework consists of two subsystems; "Monitor Sever" and "Monitor Viewer". Monitor Server is a core system of the framework. The server collects monitoring information from the DAQ subsystems to provide them to Monitor Viewer. Monitor Viewer is a graphical user interface of the monitor framework, which displays plots in itself. We adapted two types of technologies; Java and HTML5 with Google Web Toolkit, which are independent of operating systems or plugin-libraries like ROOT and contain some functionalities of communicating via the Internet and drawing graphics. The monitoring framework was developed for the Double Chooz reactor neutrino oscillation experiment but is general enough for other experiments. This document reports the structure of the online monitor framework with some examples from the adaption to the Double Chooz experiment.

  12. Rough Set Approach to Incomplete Multiscale Information System

    Science.gov (United States)

    Yang, Xibei; Qi, Yong; Yu, Dongjun; Yu, Hualong; Song, Xiaoning; Yang, Jingyu

    2014-01-01

    Multiscale information system is a new knowledge representation system for expressing the knowledge with different levels of granulations. In this paper, by considering the unknown values, which can be seen everywhere in real world applications, the incomplete multiscale information system is firstly investigated. The descriptor technique is employed to construct rough sets at different scales for analyzing the hierarchically structured data. The problem of unravelling decision rules at different scales is also addressed. Finally, the reduct descriptors are formulated to simplify decision rules, which can be derived from different scales. Some numerical examples are employed to substantiate the conceptual arguments. PMID:25276852

  13. General System theory, Like-Quantum Semantics and Fuzzy Sets

    CERN Document Server

    Licata, Ignazio

    2006-01-01

    It is outlined the possibility to extend the quantum formalism in relation to the requirements of the general systems theory. It can be done by using a quantum semantics arising from the deep logical structure of quantum theory. It is so possible taking into account the logical openness relationship between observer and system. We are going to show how considering the truth-values of quantum propositions within the context of the fuzzy sets is here more useful for systemics . In conclusion we propose an example of formal quantum coherence.

  14. A study on 4D inversion of time-lapse magnetotelluric data sets for monitoring geothermal reservoir

    Science.gov (United States)

    Jang, H.; Nam, M. J.; Song, Y.

    2015-12-01

    The productivity of geothermal reservoir, which is function of pore-space and fluid-flow path of the reservoir, varies since the properties of reservoir changes with geothermal electricity generation. The variation in the reservoir properties causes changes in electrical resistivity, time-lapse (TL) three-dimensional (3D) magnetotelluric (MT) methods can be applied to monitor the productivity variation of geothermal reservoir thanks to its sensitive to the electrical resistivity of deep subsurface. For an accurate interpretation of TL 3D MT data, a 4D MT inversion algorithm has been developed to simultaneously invert all vintage data in a time-coupled way. However, the changes in electrical resistivity of deep geothermal reservoirs are usually small generating minimum variation in TL MT responses. In order to reduce TL inversion artifacts emphasizing the TL changes, we upgrade the TL coupling of the original 4D inversion algorithm with active time constraint (ATC), which has been verified to be efficient for resistivity monitoring based on TL electrical resistivity surveys. In order to maximize the sensitivity to reservoir-region resistivity changes, we further developed a focused 4D MT inversion method by considering the distribution of reservoir fractures. To analyze the validity of the 4D algorithms, we make 4D MT inversion of synthetic TL data sets applying ATC and focusing methods, respectively, and compare their results those from the original 4D algorithm. The numerical tests find that ATC 4D inversion can be useful for conventional geothermal reservoirs, while the focused inversion algorithm can be better for monitoring engineering geothermal system (EGS) reservoir, within which new fracture can be actively developed by fluid circulation during production. This work is supported by KETEP granted by MOTIE, KOREA (NO. 20133030000220).

  15. Implementation of a Portable Personal EKG Signal Monitoring System

    Science.gov (United States)

    Tan, Tan-Hsu; Chang, Ching-Su; Chen, Yung-Fu; Lee, Cheng

    This research develops a portable personal EKG signal monitoring system to help patients monitor their EKG signals instantly to avoid the occurrence of tragedies. This system is built with two main units: signal pro-cessing unit and monitoring and evaluation unit. The first unit consists of EKG signal sensor, signal amplifier, digitalization circuit, and related control circuits. The second unit is a software tool developed on an embedded Linux platform (called CSA). Experimental result indicates that the proposed system has the practical potential for users in health monitoring. It is demonstrated to be more convenient and with greater portability than the conventional PC-based EKG signal monitoring systems. Furthermore, all the application units embedded in the system are built with open source codes, no licensed fee is required for operating systems and authorized applications. Thus, the building cost is much lower than the traditional systems.

  16. A systematic framework for design of process monitoring and control (PAT) systems for crystallization processes

    DEFF Research Database (Denmark)

    Abdul Samad, Noor Asma Fazli Bin; Sin, Gürkan; Gernaey, Krist

    2013-01-01

    for generation of the supersaturation set-point for supersaturation control, as well as a tool for design of a process monitoring and control system (also called Process Analytical Technology (PAT) system). This systematic design allows one to generate the necessary problem-chemical system specific model......A generic computer-aided framework for systematic design of a process monitoring and control system for crystallization processes has been developed to study various aspects of crystallization operations.The systematic design framework contains a generic crystallizer modelling toolbox, a tool......, the necessary supersaturation set-point as well as a PAT system design including implementation of monitoring tools and control strategies in order to produce the desired target product properties notably crystal size distribution (CSD) and shape for a wide range of crystallization processes. Application...

  17. The spectrum for overlarge sets of directed triple systems

    Institute of Scientific and Technical Information of China (English)

    Zi-hong; TIAN; Li-jun; Ji

    2007-01-01

    A directed triple system of order v, denoted by DTS(v, λ), is a pair (X,B) where X is a v-set and B is a collection of transitive triples on X such that every ordered pair of X belongs to λ triples of B. An overlarge set of disjoint DTS(v, λ), denoted by OLDTS(v, λ), is a collection {(Y\\{y}, Ai)}i,such that Y is a (v + 1)-set, each (Y\\{y}, Ai) is a DTS(v, λ) and all Ai's form a partition of all transitive triples of Y. In this paper, we shall discuss the existence problem of OLDTS(v, λ) and give the following conclusion: there exists an OLDTS(v, λ) if and only if either λ = 1 and v = 0, 1 (mod 3), or λ = 3 and v≠2.

  18. An Integrated Patient Information and In-Home Health Monitoring System Using Smartphones and Web Services.

    Science.gov (United States)

    Sorwar, Golam; Ali, Mortuza; Islam, Md Kamrul; Miah, Mohammad Selim

    2016-01-01

    Modern healthcare systems are undergoing a paradigm shift from in-hospital care to in-home monitoring, leveraging the emerging technologies in the area of bio-sensing, wireless communication, mobile computing, and artificial intelligence. In-home monitoring promises to significantly reduce healthcare spending by preventing unnecessary hospital admissions and visits to healthcare professionals. Most of the in-home monitoring systems, proposed in the literature, focus on monitoring a set of specific vital signs. However, from the perspective of caregivers it is infeasible to maintain a collection of specialized monitoring systems. In this paper, we view the problem of in-home monitoring from the perspective of caregivers and present a framework that supports various monitoring capabilities while making the complexity transparent to the end users. The essential idea of the framework is to define a 'general purpose architecture' where the system specifies a particular protocol for communication and makes it public. Then any bio-sensing system can communicate with the system as long as it conforms to the protocol. We then argue that as the system grows in terms of number of patients and bio-sensing systems, artificial intelligence technologies need to be employed for patients' risk assessment, prioritization, and recommendation. Finally, we present an initial prototype of the system designed according to the proposed framework.

  19. Extended Darknet: Multi-Dimensional Internet Threat Monitoring System

    Science.gov (United States)

    Shimoda, Akihiro; Mori, Tatsuya; Goto, Shigeki

    Internet threats caused by botnets/worms are one of the most important security issues to be addressed. Darknet, also called a dark IP address space, is one of the best solutions for monitoring anomalous packets sent by malicious software. However, since darknet is deployed only on an inactive IP address space, it is an inefficient way for monitoring a working network that has a considerable number of active IP addresses. The present paper addresses this problem. We propose a scalable, light-weight malicious packet monitoring system based on a multi-dimensional IP/port analysis. Our system significantly extends the monitoring scope of darknet. In order to extend the capacity of darknet, our approach leverages the active IP address space without affecting legitimate traffic. Multi-dimensional monitoring enables the monitoring of TCP ports with firewalls enabled on each of the IP addresses. We focus on delays of TCP syn/ack responses in the traffic. We locate syn/ack delayed packets and forward them to sensors or honeypots for further analysis. We also propose a policy-based flow classification and forwarding mechanism and develop a prototype of a monitoring system that implements our proposed architecture. We deploy our system on a campus network and perform several experiments for the evaluation of our system. We verify that our system can cover 89% of the IP addresses while darknet-based monitoring only covers 46%. On our campus network, our system monitors twice as many IP addresses as darknet.

  20. Geographic information system planning and monitoring best ...

    African Journals Online (AJOL)

    emeje

    Key words: GIS, Urban Planning, Urban Monitoring, West Africa, Best Practices, Pollution, flooding .... infrastructure and space, evident in cities such as Lagos,. Kano ... earmarked as green belts are being taken over by corner shops, roads ...

  1. Design of Wind Turbine Vibration Monitoring System

    National Research Council Canada - National Science Library

    Shoubin Wang; Wei Gong; Gang Su; Hongyue Sun

    2013-01-01

    In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed...

  2. Pier scour monitoring system by bed-level image tracking

    Institute of Scientific and Technical Information of China (English)

    Wen-Yi CHANG; Jihn-Sung LAI; Teng-Yi YU; Franco LIN; Lung-Cheng LEE; Whey-Fone TSAI; Chin-Hsiung LOH

    2014-01-01

    A scour monitoring system with a micro camera tracking the bed-level images is proposed in this study. Two image recognition algorithms have been developed to support the bed-level image tracking approach. Through the laboratory experiments of pier scour, this study demonstrates that the proposed system is able to accurately monitor the scour-depth evolution in real time. In addition, five commonly-used temporal scour models are employed to simulate scour-depth evolution and their results are compared with monitoring data. In general, the results indicate that the proposed scour monitoring system has the potential for further applications in the field.

  3. Characterization of a New Continuous Air Monitoring System For the University of Massachusetts Lowell Research Reactor

    Science.gov (United States)

    Alqahtani, Mohammad Saad

    A continuous air monitor (CAM) is a critical piece of equipment to support radiation safety in nuclear facilities where the generation of airborne radioactivity is a possibility for either normal operations or accident scenarios. The University of Massachusetts Lowell Research Reactor is planning to install a new CAM system manufactured by Canberra Industries for monitoring airborne radioactive particulates. In this study, the new CAM was evaluated to determine 1) baseline response, 2) response to high exposure rates, 3) appropriate background compensation, 4) detection limits, and 5) alarm settings. The results of this study will help to properly integrate the new CAM into the reactor radiation monitoring system.

  4. Towards a Real Estate Monitoring Information System in Romania

    Directory of Open Access Journals (Sweden)

    Paul de Vries

    2009-06-01

    Full Text Available This paper examines the construction of real estate databases and the valuation of properties in Buzau, Romania. One of the criteria for candidate states for EU membership is an effective monitoring system for the land and real estate markets.The objective of this paper is twofold. First, the development of a set of databases, procedures and guidelines that enables a valuation process on the Romanian real estate market and secondly, using those databases, to gain insight into the real market value of recently sold properties. We use the observations of estate agents and banks starting in May 2007. Using hedonic regression, with house andneighbourhood characteristics, we estimate the house prices

  5. A Microprocessor-Based System for Monitoring Gas Turbines

    Directory of Open Access Journals (Sweden)

    P. K.S. Shrivastava

    1989-04-01

    Full Text Available The development and testing of hardware and software for a microprocessor-based monitoring system for gas turbines is described in this paper. The operators of gas turbines can be trained to monitor running hours, slip between high and low pressure compressor spools and torque on the reduction gear-box under various conditions ofoperation. The system will replace the traditional method of monitoring these parameters which are more time consuming and error prone.

  6. Review on Environment Monitoring System and Energy Efficiency

    OpenAIRE

    Nikita Gaikwad; Yogita Mistry

    2015-01-01

    The Environment monitoring is one of the applications of wireless sensor network. The most serious environment pollution is air pollution because different air pollutant causes damage to human health and causes global warming. To avoid such effect on human health and climate change Environment monitoring systems are used. This paper provides the short overview of different environmental air pollution monitoring systems and Energy efficiency in WSN to reduced the power consumption ...

  7. Development of environmental monitoring satellite systems in China

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    With the increase in global environmental problems,the necessity and urgency of remote sensing technology being applied to environmental monitoring has been widely recognized around the world.China has launched the environment and disaster monitoring and forecasting small satellite constellation HJ-1A/B and the FY3 atmosphere and environmental satellite,but they still cannot fully satisfy requirements for environmental monitoring.This paper summarizes the current status of satellite environmental monitoring in China and the existing problems of inadequate load design and low data utilization efficiency,and discusses the demand for environmental monitoring satellites.Based on the development of foreign satellite systems for environmental monitoring,the future development and key tasks of the environmental monitoring satellite system in China is discussed,as are some related initiatives.

  8. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    Science.gov (United States)

    Heinz, Emanuel; Kraft, Philipp; Buchen, Caroline; Frede, Hans-Georg; Aquino, Eugenio; Breuer, Lutz

    2014-05-01

    Climate change has already a large impact on the availability of water resources. Many regions in South-East Asia are assumed to receive less water in the future, dramatically impacting the production of the most important staple food: rice (Oryza sativa L.). Rice is the primary food source for nearly half of the World's population, and is the only cereal that can grow under wetland conditions. Especially anaerobic (flooded) rice fields require high amounts of water but also have higher yields than aerobic produced rice. In the past different methods were developed to reduce the water use in rice paddies, like alternative wetting and drying or the use of mixed cropping systems with aerobic (non-flooded) rice and alternative crops such as maize. A more detailed understanding of water and nutrient cycling in rice-based cropping systems is needed to reduce water use, and requires the investigation of hydrological and biochemical processes as well as transport dynamics at the field scale. New developments in analytical devices permit monitoring parameters at high temporal resolutions and at acceptable costs without much necessary maintenance or analysis over longer periods. Here we present a new type of automatic sampling set-up that facilitates in situ analysis of hydrometric information, stable water isotopes and nitrate concentrations in spatially differentiated agricultural fields. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water) in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS) for stable water isotope analysis (δ2H and δ18O), a reagentless hyperspectral UV photometer for monitoring nitrate content and various water level sensors for hydrometric information. The whole system is maintained with special developed software for remote control of the system via internet. We

  9. Evaluation of systems and components for hybrid optical firing sets

    Energy Technology Data Exchange (ETDEWEB)

    Landry, M.J.; Rupert, J.W.; Mittas, A.

    1989-06-01

    High-energy density light appears to be a unique energy form that may be used to enhance the nuclear safety of weapon systems. Hybrid optical firing sets (HOFS) utilize the weak-link/strong-link exclusion region concept for nuclear safety; this method is similar to present systems, but uses light to transmit power across the exclusion region barrier. This report describes the assembling, operating, and testing of fourteen HOFS. These firing sets were required to charge a capacitor-discharge unit to 2.0 and 2.5 kV (100 mJ) in less than 1 s. First, we describe the components, the measurement techniques used to evaluate the components, and the different characteristics of the measured components. Second, we describe the HOFS studied, the setups used for evaluating them, and the resulting characteristics. Third, we make recommendations for improving the overall performance and suggest the best HOFS for packaging. 36 refs., 145 figs., 14 tabs.

  10. A policy system for Grid Management and Monitoring

    Science.gov (United States)

    Stagni, Federico; Santinelli, Roberto; LHCb Collaboration

    2011-12-01

    Organizations using a Grid computing model are faced with non-traditional administrative challenges: the heterogeneous nature of the underlying resources requires professionals acting as Grid Administrators. Members of a Virtual Organization (VO) can use a subset of available resources and services in the grid infrastructure and in an ideal world, the more resoures are exploited the better. In the real world, the less faulty services, the better: experienced Grid administrators apply procedures for adding and removing services, based on their status, as it is reported by an ever-growing set of monitoring tools. When a procedure is agreed and well-exercised, a formal policy could be derived. For this reason, using the DIRAC framework in the LHCb collaboration, we developed a policy system that can enforce management and operational policies, in a VO-specific fashion. A single policy makes an assessment on the status of a subject, relative to one or more monitoring information. Subjects of the policies are monitored entities of an established Grid ontology. The status of a same entity is evaluated against a number of policies, whose results are then combined by a Policy Decision Point. Such results are enforced in a Policy Enforcing Point, which provides plug-ins for actions, like raising alarms, sending notifications, automatic addition and removal of services and resources from the Grid mask. Policy results are shown in the web portal, and site-specific views are provided also. This innovative system provides advantages in terms of procedures automation, information aggregation and problem solving.

  11. Design of Magnetic Field System for Calutron Ion Source Set

    Institute of Scientific and Technical Information of China (English)

    REN; Xiu-yan; ZENG; Zi-qiang

    2013-01-01

    The Calutron ion source is the most important equipment of EMIS,and the structure of the ion source is more complicated.Because the parameter of each part is interrelate,as experiment and test set,It is very convenient to adjust the parameter of ion source and make the ion source get a good quality.Magnetic field system is the leading and necessary auxiliary equipment of the Calutron ion source

  12. FarMon:An Extensible,Efficient Cluster Monitoring System

    Institute of Scientific and Technical Information of China (English)

    YongFAN; MeiMA; 等

    2001-01-01

    This paper presents the design and implementation of FarMon-a flexible event monitoring system for computing cluster,Using several techniques including DCL (Dynamic Class Loading)technique,module publish/subacribe/unsubscribe protocol and directory service,we create a high efficient,high extensible and high portable cluster monitoring system.

  13. 47 CFR 76.614 - Cable television system regular monitoring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system regular monitoring. 76.614 Section 76.614 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.614 Cable television system regular monitoring. Cable television...

  14. Seismic monitoring: a unified system for research and verifications

    Energy Technology Data Exchange (ETDEWEB)

    Thigpen, L.

    1979-02-06

    A system for characterizing either a seismic source or geologic media from observational data was developed. This resulted from an examination of the forward and inverse problems of seismology. The system integrates many seismic monitoring research efforts into a single computational capability. Its main advantage is that it unifies computational and research efforts in seismic monitoring. 173 references, 9 figures, 3 tables.

  15. 50 CFR 660.312 - Vessel Monitoring System (VMS) requirements.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Vessel Monitoring System (VMS... West Coast Groundfish Fisheries § 660.312 Vessel Monitoring System (VMS) requirements. (a) What is a VMS? A VMS consists of a NMFS OLE type-approved mobile transceiver unit that automatically...

  16. ATLAS Pixel Radiation Monitoring with HVPP4 System

    CERN Document Server

    Gorelov, Igor; Seidel, Sally; Toms, Konstantin

    2009-01-01

    In this talk we present the basis for the protocol for radiation monitoring of the ATLAS Pixel Sensors. The monitoring is based on a current measurement system, HVPP4. The status on the ATLAS HVPP4 system development is also presented.

  17. 77 FR 67593 - Steel Import Monitoring and Analysis System

    Science.gov (United States)

    2012-11-13

    ... International Trade Administration 19 CFR Part 360 RIN 0625-AA93 Steel Import Monitoring and Analysis System... modifications to the regulations for the Steel Import Monitoring and Analysis (SIMA) System that would extend... as possible certain steel mill imports into the United States and make the import data...

  18. [A wireless mobile monitoring system based on bluetooth technology].

    Science.gov (United States)

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  19. Fault Detection for Shipboard Monitoring and Decision Support Systems

    DEFF Research Database (Denmark)

    Lajic, Zoran; Nielsen, Ulrik Dam

    2009-01-01

    In this paper a basic idea of a fault-tolerant monitoring and decision support system will be explained. Fault detection is an important part of the fault-tolerant design for in-service monitoring and decision support systems for ships. In the paper, a virtual example of fault detection will be p...

  20. Alat Monitoring Infus Set pada Pasien Rawat Inap Berbasis Mikrokontroler ATmega 8535

    Directory of Open Access Journals (Sweden)

    DECY NATALIANA

    2016-02-01

    Full Text Available Abstrak Metode yang digunakan untuk mengetahui volume cairan Infus adalah dengan cara mendeteksi tetesan yang berada pada chamber Infus. Tetesan dideteksi oleh sensor cahaya yaitu LED infra merah dan photodioda. Sinyal tegangan dari sensor dikondisikan dengan IC komparator LM339 . Mikrokontroler ATmega 8535 digunakan sebagai pengolah data  I/O dari komparator sehingga informasi dari parameter  yang dimonitor dapat ditampilkan pada LED dan LCD serta bunyi buzzer. Tegangan keluaran sensor infra merah saat mendeteksi tetesan adalah sebesar 1,02 V sedangkan saat tidak mendeteksi tetesan tegangan keluaran sebesar 180 mV. Parameter yang dapat dideteksi dari alat ini diantaranya jumlah tetesan per menit dengan maksimal jumlah tetes / menit yang dideteksi sebesar 255 tetes, peringatan bila tetesan tidak terdeteksi selama 10 detik dan peringatan bila cairan Infus akan habis (± 50 ml. Suara yang dihasilkan buzzer masih terdengar jelas dan tidak berbahaya bagi pendengaran perawat berdasarkan nilai ambang batas tingkat kebisingan meskipun keadaan di ruangan perawat dalam kondisi ramai.   Kata kunci: Infus set, intravena, photodioda, infra merah, mikrokontroler ATmega 8535, Infus.   Abstract The method used to know the volume of Infusion fluid is detecting droplets that are on Infusion chamber. The droplets are detected by the light sensors is infrared LED and  photodiode. The voltage signal from the sensor is conditioned by the digital comparator IC LM339. ATmega microcontroller 8535 is used as a data processor of the comparator output so that information from the monitored parameters can be displayed on the LCD and LED and buzzer flame. The output voltage when infrared sensors detect a drop is 1.02 V, while sensor does not detect a drop the output voltage drops is 180 mV. Parameters that can be detected from these tool include the number of drops per minute with a maximum number of drops / min was detected at 255 drops, a warning when the droplets

  1. Development of quality indicators for monitoring outcomes of frail elderly hospitalised in acute care health settings: Study Protocol

    Directory of Open Access Journals (Sweden)

    Travers Catherine M

    2011-10-01

    Full Text Available Abstract Background Frail older people admitted to acute care hospitals are at risk of a range of adverse outcomes, including geriatric syndromes, although targeted care strategies can improve health outcomes for these patients. It is therefore important to assess inter-hospital variation in performance in order to plan and resource improvement programs. Clinical quality outcome indicators provide a mechanism for identifying variation in performance over time and between hospitals, however to date there has been no routine use of such indicators in acute care settings. A barrier to using quality indicators is lack of access to routinely collected clinical data. The interRAI Acute Care (AC assessment system supports comprehensive geriatric assessment of older people within routine daily practice in hospital and includes process and outcome data pertaining to geriatric syndromes. This paper reports the study protocol for the development of aged care quality indicators for acute care hospitals. Methods/Design The study will be conducted in three phases: 1. Development of a preliminary inclusive set of quality indicators set based on a literature review and expert panel consultation, 2. A prospective field study including recruitment of 480 patients aged 70 years or older across 9 Australian hospitals. Each patient will be assessed on admission and discharge using the interRAI AC, and will undergo daily monitoring to observe outcomes. Medical records will be independently audited, and 3. Analysis and compilation of a definitive quality indicator set, including two anonymous voting rounds for quality indicator inclusion by the expert panel. Discussion The approach to quality indicators proposed in this protocol has four distinct advantages over previous efforts: the quality indicators focus on outcomes; they can be collected as part of a routinely applied clinical information and decision support system; the clinical data will be robust and will

  2. Rapid Occupant Classification System Based Rough Sets Theory

    Directory of Open Access Journals (Sweden)

    Lin Chen

    2012-09-01

    Full Text Available In the intelligent airbag system, the correct classification of occupant type is the precondition and plays an important role in controlling the airbag release time and inflation strength during emergent accidents. In the paper, the novel rapid occupant classification system is proposed in which tens of pressure sensors are needed to real-time collect pressure distribution data and then the rough sets theory is combined to extract classification knowledge from data features. Furthermore, Experiments have been done to verify its efficiency and effectiviness.

  3. Polymerization monitoring in plasma etching systems

    Science.gov (United States)

    Kim, Jinsoo

    1999-11-01

    -suppressing nature of the oxide etch. A new sensor for monitoring polymer buildup in plasma etching systems was designed, fabricated, and tested as part of this work. The device is mounted flush in the chamber wall and uses an electrothermal oscillator to measure the thermal mass change of a micromachined dielectric window as polymer deposits on it. The variation in the oscillation pulse width (cooling time) is used as the sensor output. The device operates with a typical cooling time of 2.7msec and has a thickness resolution of modified to add the needed micromachining steps, and photoresist masking was explored for the first time to protect the devices from silicon etchant (tetramethyl ammonium hydroxide: TMAH) attack. A chevron-based support structure is used on the back side of the wafer to hold the devices in wafer form after micromachining to allow testing, high-yield die separation, and non-lithographic post-TMAH processing. The device metallization, package, and O-ring-based placement structure have been designed to ensure compatibility with the plasma etching environment.

  4. WAMS-based monitoring and control of Hopf bifurcations in multi-machine power systems

    Institute of Scientific and Technical Information of China (English)

    Shao-bu WANG; Quan-yuan JIANG; Yi-jia CAO

    2008-01-01

    A method is proposed to monitor and control Hopf bifurcations in multi-machine power systems using the information from wide area measurement systems (WAMSs). The power method (PM) is adopted to compute the pair of conjugate eigenvalues with the algebraically largest real part and the corresponding eigenvectors of the Jacobian matrix of a power system. The distance between the current equilibrium point and the Hopf bifurcation set can be monitored dynamically by computing the pair of conjugate eigenvalues. When the current equilibrium point is close to the Hopf bifurcation set, the approximate normal vector to the Hopf bifurcation set is computed and used as a direction to regulate control parameters to avoid a Hopf bifurcation in the power system described by differential algebraic equations (DAEs). The validity of the proposed method is demonstrated by regulating the reactive power loads in a 14-bus power system.

  5. A Graphical User Interface in WLAN Monitoring and Management System

    Directory of Open Access Journals (Sweden)

    Jiantao Gu

    2012-04-01

    Full Text Available This paper aims at providing a graphical user interface for WLAN monitoring and management system “WLAN Inspector”, which gives network operators the software and performance management tools necessary to monitor and manage network availability, achieve real-time monitoring (7 × 24 hours and intelligent management, report on IP networks performance, and troubleshoot issues through a single Web-based graphical user interface. The overall framework design of graphical interface, brief description of each module, and the detailed design in the basic information interface are discussed in this paper. The WLAN monitoring and management system has multiple functions: real-time network monitoring, real-time protocol analysis, information, statistics, safety testing and network performance monitoring, etc. This system can give Video Frame Capture for Mac, analyze the WLAN traffic characteristics, detect possible security vulnerabilities, and give the appropriate solution.

  6. Use of satellite images for the monitoring of water systems

    Science.gov (United States)

    Hillebrand, Gudrun; Winterscheid, Axel; Baschek, Björn; Wolf, Thomas

    2015-04-01

    Satellite images are a proven source of information for monitoring ecological indicators in coastal waters and inland river systems. This potential of remote sensing products was demonstrated by recent research projects (e.g. EU-funded project Freshmon - www.freshmon.eu) and other activities by national institutions. Among indicators for water quality, a particular focus was set on the temporal and spatial dynamics of suspended particulate matter (SPM) and Chlorophyll-a (Chl-a). The German Federal Institute of Hydrology (BfG) was using the Weser and Elbe estuaries as test cases to compare in-situ measurements with results obtained from a temporal series of automatically generated maps of SPM distributions based on remote sensing data. Maps of SPM and Chl-a distributions in European inland rivers and alpine lakes were generated by the Freshmon Project. Earth observation based products are a valuable source for additional data that can well supplement in-situ monitoring. For 2015, the BfG and the Institute for Lake Research of the State Institute for the Environment, Measurements and Nature Conservation of Baden-Wuerttemberg, Germany (LUBW) are in the process to start implementing an operational service for monitoring SPM and Chl-a based on satellite images (Landsat 7 & 8, Sentinel 2, and if required other systems with higher spatial resolution, e.g. Rapid Eye). In this 2-years project, which is part of the European Copernicus Programme, the operational service will be set up for - the inland rivers of Rhine and Elbe - the North Sea estuaries of Elbe, Weser and Ems. Furthermore - Lake Constance and other lakes located within the Federal State of Baden-Wuerttemberg. In future, the service can be implemented for other rivers and lakes as well. Key feature of the project is a data base that holds the stock of geo-referenced maps of SPM and Chl-a distributions. Via web-based portals (e.g. GGInA - geo-portal of the BfG; UIS - environmental information system of the

  7. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  8. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The on-ground and Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) provides a system architecture and software tools for performing diagnostics...

  9. Efficient Network Monitoring for Large Data Acquisition Systems

    CERN Document Server

    Savu, DO; The ATLAS collaboration; Al-Shabibi, A; Sjoen, R; Batraneanu, SM; Stancu, SN

    2011-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed real-time data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and...

  10. [Implementation of ECG Monitoring System Based on Internet of Things].

    Science.gov (United States)

    Lu, Liangliang; Chen, Minya

    2015-11-01

    In order to expand the capabilities of hospital's traditional ECG device and enhance medical staff's work efficiency, an ECG monitoring system based on internet of things is introduced. The system can monitor ECG signals in real time and analyze data using ECG sensor, PDA, Web servers, which embeds C language, Android systems, .NET, wireless network and other technologies. After experiments, it can be showed that the system has high reliability and stability and can bring the convenience to medical staffs.

  11. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  12. Test of GBAS Integrity Monitoring System Using GPS Simulator

    Institute of Scientific and Technical Information of China (English)

    Yun Young-sun; Park Sung-min; Kee Chang-don

    2003-01-01

    In recent years, many countries are developing aircraft navigation systems using GNSS(Global Navigation Satellite System),because GNSS has many technical and economic benefits. International organizations as ICAO(International Civil Aviation Organization) and RTCA(Radio Technical Commission for Aeronautics) set up international standards of GBAS(Ground Based Augmentation System)using GNSS and recommend countries to develop GBAS that is based on the standards. To go with the international stream, Korea Airport Cooperation has also developed GBAS. For evaluating the system,KAC and Seoul National University have performed flight tests of the developed GBAS several times and have concluded that the system has good accuracy enough to be used in aircrafts. At that time, the purpose of tests was focused on accuracy of GBAS. But integrity of the system which is important for safety of aircrafts was not tested sufficiently,because it is impossible to make erroneous situations of real GPS signals. So, at this time, we used GPS simulator which can generate GPS signals with satellite failure scenarios. The GPS simulator used in this test generates GPS signals by the scenarios organized in advance.The scenarios can include pseudorange and carrier phase error, parity error and etc. So we organized several scenarios which can includes potential errors of GPS signals and many possible cases for testing the system effectively and accurately. And we tested integrity function of the GBAS system by using GPS signals generated by the simulator.This paper introduces the implemented integrity monitoring system and algorithms used in the tests. And it describes the scenarios of satellite failure. Finally, this paper shows the results of tests.

  13. Standard-B Hydrogen Monitoring System, system design description

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1995-01-16

    During most of the year, it is assumed that the vapor in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gases to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gases from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. This document describes the design of the Standard-B Hydrogen Monitoring System, (SHMS) and its components as it differs from the original SHMS. The differences are derived from changes made to improve the system performance but not implemented in all the installed enclosures.

  14. Iterative user-centered design of a next generation patient monitoring system for emergency medical response.

    Science.gov (United States)

    Gao, Tia; Kim, Matthew I; White, David; Alm, Alexander M

    2006-01-01

    We have developed a system for real-time patient monitoring during large-scale disasters. Our system is designed with scalable algorithms to monitor large numbers of patients, an intuitive interface to support the overwhelmed responders, and ad-hoc mesh networking capabilities to maintain connectivity to patients in the chaotic settings. This paper describes an iterative approach to user-centered design adopted to guide development of our system. This system is a part of the Advanced Health and Disaster Aid Network (AID-N) architecture.

  15. Development of mobile air pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  16. Monitoring of PON System Using Compound Surveillance Technique

    Institute of Scientific and Technical Information of China (English)

    Sun-Chien Ko; Hsiu-Jung Chuang; Si-Chong Chen; Chih-Yih Wang; Sheng-Fwu Lin

    2015-01-01

    A passive optical network (PON) monitoring system combined light pulse and frequency sweep techniques is proposed and verified in a field test. The light pulse surveys over the all whole network and the frequency sweep are used to investigate any fault in the link. The field test is performed with 4 PONs. Each PON is monitored at 4 ports, one is the splitter port and the other three are arbitrary chosen multiple optical units(ONUs). All the tested PONs are monitored in turns once per hour. Faults at the feeder and branch fiber have been observed in this field test and have been analyzed with the monitoring system.

  17. Development of mobile air pollution monitoring system (LIDAR)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyung Ki; Song, Kyu Seok; Kim, Dukh Yeon; Yang, Ki Ho; Lee, Jong Min; Yoon, S.; Rostov, A

    2001-01-01

    Most air pollution monitoring technologies accompany a time-consuming sample treatment and provide pollution information only for a local area. Thus, they have a critical restriction in monitoring time-dependent pollution variation effectively over the wide range of area both in height and in width. LIDAR(Light Detection And Ranging) is a new technology to overcome such drawbacks of the existing pollution monitoring technologies and has long been investigated in the advanced countries. The coal of this project is to develop the mobile air pollution monitoring system and to apply the system to the detection of various pollutants, such as ozone, nitrogen dioxide, sulfur dioxide and aerosols.

  18. Effect of Frequent Peer-Monitored Testing and Personal Goal Setting on Fitnessgram Scores of Hispanic Middle School Students

    Science.gov (United States)

    Hill, Grant; Downing, Aaron

    2015-01-01

    The purpose of this study was to determine the effects of frequent peer-monitored Fitnessgram testing, with student goal setting, on the PACER and push-up performance of middle school students. Subjects were 176 females and 189 males in 10 physical education classes at a middle school with an 83.7% Hispanic student population. Students were…

  19. Seismic Monitoring System Calibration Using Ground Truth Database

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Winston; Wagner, Robert

    2002-12-22

    Calibration of a seismic monitoring system remains a major issue due to the lack of ground truth information and uncertainties in the regional geological parameters. Rapid and accurate identification of seismic events is currently not feasible due to the absence of a fundamental framework allowing immediate access to ground truth information for many parts of the world. Precise location and high-confidence identification of regional seismic events are the primary objectives of monitoring research in seismology. In the Department of Energy Knowledge Base (KB), ground truth information addresses these objectives and will play a critical role for event relocation and identification using advanced seismic analysis tools. Maintaining the KB with systematic compilation and analysis of comprehensive sets of geophysical data from various parts of the world is vital. The goal of this project is to identify a comprehensive database for China using digital seismic waveform data that are currently unavailable. These data may be analyzed along with ground truth information that becomes available. To date, arrival times for all regional phases are determined on all events above Mb 4.5 that occurred in China in 2000 and 2001. Travel-time models are constructed to compare with existing models. Seismic attenuation models may be constructed to provide better understanding of regional wave propagation in China with spatial resolution that has not previously been obtained.

  20. Designing minimum data sets of health smart card system

    Directory of Open Access Journals (Sweden)

    Mohtaram Nematollahi

    2014-10-01

    Full Text Available Introduction: Nowadays different countries benefit from health system based on health cards and projects related to smart cards. Lack of facilities which cover this technology is obvious in our society. This paper aims to design Minimum Data Sets of Health Smart Card System for Iran. Method: This research was an applied descriptive study. At first, we reviewed the same projects and guidelines of selected countries and the proposed model was designed in accordance to the country’s needs, taking people’s attitude about it by Delphi technique. A data analysis in study stage of MDS(Minimum Data Sets of Health Smart Card in the selective countries was done by comparative tables and determination of similarities and differences of the MDS. In the stage of gaining credit for model, it was accomplished with descriptive statistics to the extent of absolute and relative frequency through SPSS (version 16. Results: MDS of Health Smart Card for Iran is presented in the patient’s card and health provider’s card on basisof studiesin America, Australia, Turkey and Belgium and needs of our country and after doing Delphi technique with 94 percent agreement confirmed. Conclusion: Minimum Data Sets of Health Smart Card provides continuous care for patients and communication among providers. So, it causes a decrease in the complications of threatening diseases. Collection of MDS of diseases increases the quality of care assessment

  1. School absence and treatment in school children with respiratory symptoms in the Netherlands: Data from the Child Health Monitoring System

    NARCIS (Netherlands)

    Spee-van Der Wekke, J.; Meulmeester, J.F.; Radder, J.J.; Verloove-Vanhorick, S.P.

    1998-01-01

    Study objective - To assess the prevalence of respiratory problems, and the relation of these problems with school attendance, medicine use, and medical treatment. Design - The Child Health Monitoring System. Setting - Nineteen public health services across the Netherlands. Participants - 5186

  2. A New Architecture of a Ubiquitous Health Monitoring System: A Prototype Of Cloud Mobile Health Monitoring System

    CERN Document Server

    Bourouis, Abderrahim; Bouchachia, Abdelhamid

    2012-01-01

    Wireless Body Area Sensor Networks (WBASN) is an emerging technology which uses wireless sensors to implement real-time wearable health monitoring of patients to enhance independent living. In this paper we propose a prototype of cloud mobile health monitoring system. The system uses WBASN and Smartphone application that uses cloud computing, location data and a neural network to determine the state of patients.

  3. Intelligent Monitoring of Rocket Test Systems

    Science.gov (United States)

    Duran, Esteban; Rocha, Stephanie; Figueroa, Fernando

    2016-01-01

    Stephanie Rocha is an undergraduate student pursuing a degree in Mechanical Engineering. Esteban Duran is pursuing a degree in Computer Science. Our mentor is Fernando Figueroa. Our project involved developing Intelligent Health Monitoring at the High Pressure Gas Facility (HPGF) utilizing the software GensymG2.

  4. Design Optimization of Structural Health Monitoring Systems

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, Eric B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-03-06

    Sensor networks drive decisions. Approach: Design networks to minimize the expected total cost (in a statistical sense, i.e. Bayes Risk) associated with making wrong decisions and with installing maintaining and running the sensor network itself. Search for optimal solutions using Monte-Carlo-Sampling-Adapted Genetic Algorithm. Applications include structural health monitoring and surveillance.

  5. Information Fusion of Online Oil Monitoring System Using Multiple Sensors

    Institute of Scientific and Technical Information of China (English)

    高慧良; 周新聪; 程海明; 赵春华; 严新平

    2004-01-01

    Machine lubrication contains abundant information on the equipment operation.Nowadays, most measuring methods are based on offline sampling or on online measuring with a single sensor.An online oil monitoring system with multiple sensors was designed.The measurement data was processed with a fuzzy intelligence system.Information from integrated sensors in an oil online monitoring system was evaluated using fuzzy logic.The analyses show that the multiple sensors evaluation results are more reliable than online monitoring systems with single sensors.

  6. A wireless portable system with microsensors for monitoring respiratory diseases.

    Science.gov (United States)

    Cao, Zhe; Zhu, Rong; Que, Rui-Yi

    2012-11-01

    A wireless portable monitoring system for respiratory diseases using microsensors is proposed. The monitoring system consists of two sensor nodes integrating with Bluetooth transmitters that measure user's respiratory airflow, blood oxygen saturation, and body posture. The utility of micro-hot-film flow sensor makes the monitor can acquire comprehensive respiration parameters which are useful for diagnoses of obstructive sleep apnea, chronic obstructive pulmonary disease, and asthma. The system can serve as both sleep recorder and spirometer. Additionally, a mobile phone or a PC connected to the Internet serving as a monitoring and transfer terminal makes telemedicine achievable. Several experiments were conducted to verify the feasibility and effectiveness of the proposed system for monitoring and diagnosing OSA, COPD, and asthma.

  7. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  8. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  9. Setting development goals using stochastic dynamical system models

    Science.gov (United States)

    Nicolis, Stamatios C.; Bali Swain, Ranjula; Sumpter, David J. T.

    2017-01-01

    The Millennium Development Goals (MDG) programme was an ambitious attempt to encourage a globalised solution to important but often-overlooked development problems. The programme led to wide-ranging development but it has also been criticised for unrealistic and arbitrary targets. In this paper, we show how country-specific development targets can be set using stochastic, dynamical system models built from historical data. In particular, we show that the MDG target of two-thirds reduction of child mortality from 1990 levels was infeasible for most countries, especially in sub-Saharan Africa. At the same time, the MDG targets were not ambitious enough for fast-developing countries such as Brazil and China. We suggest that model-based setting of country-specific targets is essential for the success of global development programmes such as the Sustainable Development Goals (SDG). This approach should provide clear, quantifiable targets for policymakers. PMID:28241057

  10. Rough Set Fuzzy Optimum Selecting in Multidisciplinary System

    Institute of Scientific and Technical Information of China (English)

    LIU Xu-lin; SONG Bao-wei; WANG Jin-hua; CHEN Jie

    2008-01-01

    Scheme evaluation and selection is an optimum selecting and sequencing problem with multi-objective and multi- level. It can't follow single objective function or rule. Meanwhile, these objectives are coupled with each other and the at- tribution information is fuzzy also. It is necessary to find an effective evaluation method which can consider all conditions and restrictions. In this paper, AHP and rough set theory are applied to fuzzy optimization to determine important weight of each attribution. The rough set fuzzy optimum selection is used to eliminate the useless information. Autonomous un- derwater vehicle (AUV) is large-scah systems with many coupled design variables and objective functions. Their scheme evaluation and selection are very important, which relate to multiple factors, such as reliability;security, service time; the lifeeyele, etc. Results of application in torpedo design indicate that this method is feasible.

  11. λ-fold indecomposable large sets of Steiner triple systems

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    A family (X, B1), (X, B2), . . . , (X, Bq) of q STS(v)s is a λ-fold large set of STS(v) and denoted by LSTSλ(v) if every 3-subset of X is contained in exactly λ STS(v)s of the collection. It is indecomposable and denoted by IDLSTSλ(v) if there exists no LSTSλ (v) contained in the collection for any λ < λ. In 1995, Griggs and Rosa posed a problem: For which values of λ > 1 and orders v ≡ 1, 3 (mod 6) do there exist IDLSTSλ(v)? In this paper, we use partitionable candelabra systems (PCSs) and holey λ-fold large set of STS(v) (HLSTSλ(v)) as auxiliary designs to establish a recursive construction for IDLSTSλ(v) and show that there exists an IDLSTSλ(v) for λ = 2, 3, 4 and v ≡ 1, 3 (mod 6).

  12. Setting development goals using stochastic dynamical system models.

    Science.gov (United States)

    Ranganathan, Shyam; Nicolis, Stamatios C; Bali Swain, Ranjula; Sumpter, David J T

    2017-01-01

    The Millennium Development Goals (MDG) programme was an ambitious attempt to encourage a globalised solution to important but often-overlooked development problems. The programme led to wide-ranging development but it has also been criticised for unrealistic and arbitrary targets. In this paper, we show how country-specific development targets can be set using stochastic, dynamical system models built from historical data. In particular, we show that the MDG target of two-thirds reduction of child mortality from 1990 levels was infeasible for most countries, especially in sub-Saharan Africa. At the same time, the MDG targets were not ambitious enough for fast-developing countries such as Brazil and China. We suggest that model-based setting of country-specific targets is essential for the success of global development programmes such as the Sustainable Development Goals (SDG). This approach should provide clear, quantifiable targets for policymakers.

  13. Principles in wireless building health monitoring systems.

    Science.gov (United States)

    Pentaris, F. P.; Makris, J. P.; Stonham, J.; Vallianatos, F.

    2012-04-01

    Monitoring the structural state of a building is essential for the safety of the people who work, live, visit or just use it as well as for the civil protection of urban areas. Many factors can affect the state of the health of a structure, namely man made, like mistakes in the construction, traffic, heavy loads on the structures, explosions, environmental impacts like wind loads, humidity, chemical reactions, temperature changes and saltiness, and natural hazards like earthquakes and landslides. Monitoring the health of a structure provides the ability to anticipate structural failures and secure the safe use of buildings especially those of public services. This work reviews the state of the art and the challenges of a wireless Structural Health Monitoring (WiSHM). Literature review reveals that although there is significant evolution in wireless structural health monitoring, in many cases, monitoring by itself is not enough to predict when a structure becomes inappropriate and/or unsafe for use, and the damage or low durability of a structure cannot be revealed (Chintalapudi, et al., 2006; Ramos, Aguilar, & Lourenço, 2011). Several features and specifications of WiSHM like wireless sensor networking, reliability and autonomy of sensors, algorithms of data transmission and analysis should still be evolved and improved in order to increase the predictive effectiveness of the SHM (Jinping Ou & Hui Li, 2010; Lu & Loh, 2010) . Acknowledgments This work was supported in part by the ARCHEMEDES III Program of the Ministry of Education of Greece and the European Union in the framework of the project entitled «Interdisciplinary Multi-Scale Research of Earthquake Physics and Seismotectonics at the front of the Hellenic Arc (IMPACT-ARC) ».

  14. Mobile health monitoring system for community health workers

    CSIR Research Space (South Africa)

    Sibiya, G

    2014-09-01

    Full Text Available . Functional description The application provides technology for real time, dependable and intelligent health monitoring by health workers in the field. It integrates a set of wearable wireless sensors with a mobile computing device, such as a 3... communities remain a challenge for many governments, technological innovations that can increase prevention and control of NCDs are needed. Wearable health devices such as ambulatory blood pressure (ABP) monitors are a step in the right direction. ABP...

  15. A microchip CD4 counting method for HIV monitoring in resource-poor settings.

    Directory of Open Access Journals (Sweden)

    William R Rodriguez

    2005-07-01

    Full Text Available BACKGROUND: More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. METHODS AND FINDINGS: Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95 over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. CONCLUSION: Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.

  16. Real-time monitoring of the setting reaction of brushite-forming cement using isothermal differential scanning calorimetry.

    Science.gov (United States)

    Hofmann, M P; Nazhat, S N; Gbureck, U; Barralet, J E

    2006-11-01

    The setting behavior of a brushite-forming cement (beta-tricalcium phosphate/mono calcium monophosphate) was investigated using an indentation technique (the Gillmore needles method) and isothermal differential scanning calorimetry (DSC). The two objectives of the study were to investigate whether DSC could be used to real-time monitor a fast-setting calcium phosphate cement (CPC) and to determine if it is possible to correlate DSC results directly with conventional setting-time measurements. Best-fit linear correlation analysis revealed that both the initial and final setting time (T(i) and T(f)) measured by indentation were strongly correlated to the maximum heat flow measured with DSC. It seems therefore possible to predict the setting times, usually achieved with user dependent indentation methods, of this specific fast setting CPC on the basis of objective DSC measurements. The drawbacks of DSC, however, are its overall complexity and expense and the fact that only exothermal reactions can be investigated in comparison to the Gillmore needles method, furthermore, it is not possible to monitor the complete reaction as the first 2 or 3 min are lost due to sample preparation and apparatus set up.

  17. TU-CD-304-09: Feasibility Study for Thermoplastic Mask Set Up Monitoring Using Force Sensing Resistor (FSR) Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T; Cho, M; Kang, S; Kim, D; Kim, K; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States)

    2015-06-15

    Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with a head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid

  18. Structural health monitoring system/method using electroactive polymer fibers

    Science.gov (United States)

    Scott-Carnell, Lisa A. (Inventor); Siochi, Emilie J. (Inventor)

    2013-01-01

    A method for monitoring the structural health of a structure of interest by coupling one or more electroactive polymer fibers to the structure and monitoring the electroactive responses of the polymer fiber(s). Load changes that are experienced by the structure cause changes in the baseline responses of the polymer fiber(s). A system for monitoring the structural health of the structure is also provided.

  19. Stabilization and set-point regulation of underactuated mechanical systems

    Science.gov (United States)

    Loccufier, Mia

    2016-09-01

    Mechanical systems are referred to as underactuated if the number of independent actuators are fewer than the number of degrees of freedom, a general encountered problem in engineering applications. The considered mechanical systems belong to the class of Euler- Lagrange systems where both kinetic energy and potential energy are modeled in their most general form and energy dissipation is modeled according to the dissipation function of Rayleigh, i.e. viscous damping forces are assumed. The control objectives are stabilization and set-point regulation. The structure of the controller is a parallel combination of static output feedback with dynamic output feedback where nonlinear amplifiers are included. An energy based approach with Liapunov functions and the Kalman-Yacubovich-Popov main lemma yields alternative stability theorems. A number of conditions are introduced with respect to the controller's structure in order to guarantee stability. However, sufficient design freedom is left to choose a proper tuning principle and obtain the specified control objectives such as fast convergence to a set-point combined with disturbance rejection. A restriction on the control input energy can be incorporated as well. The applicability of the method will be illustrated with planar manipulators. The main contribution is that a methodology is developed which incorporates many controllers and tuning facilities.

  20. A microprocessor-based system for continuous monitoring of radiation levels around the CERN PS and PSB accelerators

    Science.gov (United States)

    Agoritsas, V.; Beck, F.; Benincasa, G. P.; Bovigny, J. P.

    1986-06-01

    This paper describes a new beam loss monitor system which has been installed in the PS and PSB machines, replacing an earlier system. The new system is controlled by a microprocessor which can operate independently of the accelerator control system, though setting up and central display are usually done remotely, using the standard control system facilities.

  1. Microprocessor-based system for continuous monitoring of radiation levels around the CERN PS and PSB accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Agoritsas, V.; Beck, F.; Benincasa, G.P.; Bovigny, J.P.

    1986-06-01

    This paper describes a new beam loss monitor system which has been installed in the PS and PSB machines, replacing an earlier system. The new system is controlled by a microprocessor which can operate independently of the accelerator control system, though setting up and central display are usually done remotely, using the standard control system facilities.

  2. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    Science.gov (United States)

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  3. Mental health in humanitarian settings: shifting focus to care systems.

    Science.gov (United States)

    Jordans, Mark J D; Tol, Wietse A

    2013-03-01

    Mental health in low- and middle income countries has received increasing attention. This attention has shifted focus, roughly moving from demonstrating the burden of mental health problems, to establishing an evidence base for interventions, to thinking about care delivery frameworks. This paper reviews these trends specifically for humanitarian settings and discusses lessons learned. Notably, that mental health assessments need to go beyond measuring the impact of traumatic events on circumscribed psychiatric disorders; that evidence for effectiveness of interventions is still too weak and its focus too limited; and that development of service delivery in the context of instable community and health systems should be an area of key priority.

  4. IEEE 802.11 ECG monitoring system.

    Science.gov (United States)

    Tejero-Calado, Juan; Lopez-Casado, Carmen; Bernal-Martin, Antonio; Lopez-Gomez, Miguel; Romero-Romero, Marco; Quesada, Guillermo; Lorca, Julio; Rivas, Ramon

    2005-01-01

    New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. This kind of devices favours at-home hospitalization, reducing the affluence to sanitary assistance centers to make routine controls. This fact causes a really favourable social impact, especially for elder people, rural-zone inhabitant, chronic patients and handicapped people. Furthermore, it offers new functionalities to physicians and will reduce the sanitary cost. Among these functionalities, biomedical signals can be sent to other devices (screen, PDA, PC...) or processing centers, without restricting the patients' mobility. The aim of this project is the development and implementation of a reduced size multi-channel electrocardiograph based on IEEE 802.11, which allows wireless monitoring of patients, and the insertion of the information into the TCP/IP Hospital network.

  5. An Expert System Applied in Construction Water Quality Monitoring

    Directory of Open Access Journals (Sweden)

    Leila Ooshaksaraie

    2011-01-01

    Full Text Available Problem statement: An untoward environmental impact of urban growth in Malaysia has been deterioration in a number of watercourses due to severe siltation and other pollutants from the construction site. Water quality monitoring is a plan for decision makers to take into account the adverse impacts of construction activities on the receiving water bodies. It is also a process for collecting the construction water quality monitoring, baseline data and standard level. Approach: In recent years, expert systems have been used extensively in different applications areas including environmental studies. In this study, expert system software -CWQM- developed by using Microsoft Visual Basic was introduced. CWQM to be used for water quality monitoring during construction activities was designed based on the legal process in Malaysia. Results: According to the water quality monitoring regulation enacted in Malaysia, construction activities require mandatory water quality monitoring plans duly approved by Department of Environment before staring activities. CWQM primarily aims to provide educational and support system for water quality monitoring engineers and decision-makers during construction activities. It displays water quality monitoring plan in report form, water sampling location in GIS format and water quality monitoring data in graph. Conclusion: When the use of CWQM in construction water quality monitoring becomes widespread, it is highly possible that it will be benefited in terms of having more accurate and objective decisions on construction projects which are mainly focused on reducing the stormwater pollution.

  6. Common accounting system for monitoring the ATLAS Distributed Computing resources

    CERN Document Server

    Karavakis, E; The ATLAS collaboration; Campana, S; Gayazov, S; Jezequel, S; Saiz, P; Sargsyan, L; Schovancova, J; Ueda, I

    2014-01-01

    This paper covers in detail a variety of accounting tools used to monitor the utilisation of the available computational and storage resources within the ATLAS Distributed Computing during the first three years of Large Hadron Collider data taking. The Experiment Dashboard provides a set of common accounting tools that combine monitoring information originating from many different information sources; either generic or ATLAS specific. This set of tools provides quality and scalable solutions that are flexible enough to support the constantly evolving requirements of the ATLAS user community.

  7. An algorithm for decomposing a polynomial system into normal ascending sets

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    We present an algorithm to decompose a polynomial system into a finite set of normal ascending sets such that the set of the zeros of the polynomial system is the union of the sets of the regular zeros of the normal ascending sets. If the polynomial system is zero dimensional, the set of the zeros of the polynomials is the union of the sets of the zeros of the normal ascending sets.

  8. Monitoring drug markets in the Internet age and the evolution of drug monitoring systems in Australia.

    Science.gov (United States)

    Burns, Lucy; Roxburgh, Amanda; Bruno, Raimondo; Van Buskirk, Joe

    2014-01-01

    In Australia, drug monitoring systems have been in place for more than a decade allowing for the measurement of ongoing trends in drug use and the detection of new drugs. The Drug Trends Unit at the National Drug and Alcohol Research Centre monitors drugs through four separate systems. The Illicit Drug Reporting System (IDRS) measures the price, purity, and availability of drugs that are primarily injected. The Ecstasy and Related Drugs Reporting System (EDRS) monitors psychostimulants that are used recreationally. The National Illicit Drugs Indicator Project (NIDIP) analyzes indicator data including drug-related hospitalizations and deaths. Finally, the Drugs and Emerging Technologies Project (DNeT) analyzes the role of the Internet in the procurement and use of novel psychoactive substances. This paper provides an overview of each component of the system, demonstrating how the system has evolved over time.

  9. Towards a barrier height benchmark set for biologically relevant systems

    Directory of Open Access Journals (Sweden)

    Jimmy C. Kromann

    2016-05-01

    Full Text Available We have collected computed barrier heights and reaction energies (and associated model structures for five enzymes from studies published by Himo and co-workers. Using this data, obtained at the B3LYP/6- 311+G(2d,2p[LANL2DZ]//B3LYP/6-31G(d,p level of theory, we then benchmark PM6, PM7, PM7-TS, and DFTB3 and discuss the influence of system size, bulk solvation, and geometry re-optimization on the error. The mean absolute differences (MADs observed for these five enzyme model systems are similar to those observed for PM6 and PM7 for smaller systems (10–15 kcal/mol, while DFTB results in a MAD that is significantly lower (6 kcal/mol. The MADs for PMx and DFTB3 are each dominated by large errors for a single system and if the system is disregarded the MADs fall to 4–5 kcal/mol. Overall, results for the condensed phase are neither more or less accurate relative to B3LYP than those in the gas phase. With the exception of PM7-TS, the MAD for small and large structural models are very similar, with a maximum deviation of 3 kcal/mol for PM6. Geometry optimization with PM6 shows that for one system this method predicts a different mechanism compared to B3LYP/6-31G(d,p. For the remaining systems, geometry optimization of the large structural model increases the MAD relative to single points, by 2.5 and 1.8 kcal/mol for barriers and reaction energies. For the small structural model, the corresponding MADs decrease by 0.4 and 1.2 kcal/mol, respectively. However, despite these small changes, significant changes in the structures are observed for some systems, such as proton transfer and hydrogen bonding rearrangements. The paper represents the first step in the process of creating a benchmark set of barriers computed for systems that are relatively large and representative of enzymatic reactions, a considerable challenge for any one research group but possible through a concerted effort by the community. We end by outlining steps needed to expand and

  10. An innovative system for 3D clinical photography in the resource-limited settings

    Science.gov (United States)

    2014-01-01

    Background Kaposi’s sarcoma (KS) is the most frequently occurring cancer in Mozambique among men and the second most frequently occurring cancer among women. Effective therapeutic treatments for KS are poorly understood in this area. There is an unmet need to develop a simple but accurate tool for improved monitoring and diagnosis in a resource-limited setting. Standardized clinical photographs have been considered to be an essential part of the evaluation. Methods When a therapeutic response is achieved, nodular KS often exhibits a reduction of the thickness without a change in the base area of the lesion. To evaluate the vertical space along with other characters of a KS lesion, we have created an innovative imaging system with a consumer light-field camera attached to a miniature “photography studio” adaptor. The image file can be further processed by computational methods for quantification. Results With this novel imaging system, each high-quality 3D image was consistently obtained with a single camera shot at bedside by minimally trained personnel. After computational processing, all-focused photos and measurable 3D parameters were obtained. More than 80 KS image sets were processed in a semi-automated fashion. Conclusions In this proof-of-concept study, the feasibility to use a simple, low-cost and user-friendly system has been established for future clinical study to monitor KS therapeutic response. This 3D imaging system can be also applied to obtain standardized clinical photographs for other diseases. PMID:24929434

  11. An atmosphere monitoring system for the Sardinia radio telescope

    Science.gov (United States)

    Buffa, F.; Bolli, P.; Sanna, G.; Serra, G.

    2017-01-01

    The Sardinia radio telescope (SRT) is a new facility managed by the Italian National Institute for Astrophysics (INAF). SRT will detect the extremely faint radio wave signals emitted by astronomical objects in a wide frequency range from decimeter to millimeter wavelengths. Especially at high frequencies (>10 GHz), specific weather conditions and interactions between signal and atmospheric constituents (mainly water and oxygen molecules) affect the radio astronomic observation reducing the antenna performances. Thus, modern ground-based telescopes are usually equipped with systems able to examine in real-time several atmospheric parameters (opacity, integrated water vapor, etc.), and in some cases to forecast the weather conditions (wind, rain, snow, etc.), in order to ensure the antenna safety and support the schedule of the telescope observations. Here, we describe the atmosphere monitoring system (AMS) realized with the aim to improve the SRT operative efficiency. It consists of a network of different sensors such as radiometers, radiosondes, weather stations, GPS and some well-established weather models. After a validation of the scheme, we successfully tested the AMS in two real practical scenarios, comparing the AMS outcomes with those of independent techniques. In the first one we were able to detect an incoming storm front applying different techniques (GPS, radiometer and the weather forecast model), while in the last one we modeled the SRT antenna system temperature at 22 GHz processing the AMS data set.

  12. Bragg grating structural sensing system for bridge monitoring

    Science.gov (United States)

    Measures, Raymond M.; Alavie, A. Tino; Maaskant, Robert; Ohn, Myo M.; Karr, Shawn E.; Huang, Shang Yuan

    1994-09-01

    Corrosion of steel within bridges and other large concrete structures has become a serious problem and consequently there is growing interest in replacing the steel within such structures with carbon fiber based composite materials. The first highway bridge in the world to use carbon fiber composite prestressing tendons was constructed and opened to the public in the fall of 1993. This two span bridge was also unique in another respect, it is the first highway bridge in the world to have been built with a set of fiber optic Bragg grating sensors structurally integrated into several of its precast concrete deck support girders. A four-channel fiber laser sensor demodulation system that was rugged, compact and transportable was developed for this project. This demodulation system monitored the changes in the internal strain on all three types (steel and two types of carbon fiber composite) of prestressing tendons over several months. The same structurally integrated fiber optic sensing system has also been used to measure the change in the internal strain within the deck girders arising from both static and dynamic loading of the bridge with a large truck.

  13. The measurement procedure in the SEMONT monitoring system.

    Science.gov (United States)

    Djuric, Nikola; Kljajic, Dragan; Kasas-Lazetic, Karolina; Bajovic, Vera

    2014-03-01

    The measurement procedure of the open area in situ electric field strength is presented, acquiring the real field data for testing of the Serbian electromagnetic field monitoring network (SEMONT) and its Internet portal. The SEMONT monitoring system introduces an advanced approach of wireless sensor network utilization for the continuous supervision of overall and cumulative level of electromagnetic field over the observed area. The aim of the SEMONT system is to become a useful tool for the national and municipal agencies for the environmental protection, regarding the electromagnetic pollution monitoring and the exposure assessment of the general population. Considering the public concern on the potentially harmful effects of the long-term exposure to electromagnetic radiation, as well as the public transparency principle that is incorporated into the Serbian law on non-ionizing radiation protection, the SEMONT monitoring system is designed for the long-term continuous monitoring, presenting real-time measurement results, and corresponding exposure assessment over the public Internet network.

  14. A Novel Electric Bicycle Battery Monitoring System Based on Android Client

    Directory of Open Access Journals (Sweden)

    Chuanxue Song

    2017-01-01

    Full Text Available The battery monitoring system (BMS plays a crucial role in maintaining the safe operation of the lithium battery electric bicycle and prolonging the life of the battery pack. This paper designed a set of new battery monitoring systems based on the Android system and ARM single-chip microcomputer to enable direct management of the lithium battery pack and convenient monitoring of the state of the battery pack. The BMS realizes the goal of monitoring the voltage, current, and ambient temperature of lithium batteries, estimating the state of charge (SOC and state of health (SOH, protecting the battery from abuse during charging or discharging, and ensuring the consistency of the batteries by integrating the passive equalization circuit. The BMS was proven effective and feasible through several tests, including charging/discharging, estimation accuracy, and communication tests. The results indicated that the BMS could be used in the design and application of the electric bicycle.

  15. Forest dynamics, SILVI-STAR : a comprehensive monitoring system

    NARCIS (Netherlands)

    Koop, H.

    1989-01-01

    To learn about the interactions between individual trees and between trees and other forest organisms, long-term monitoring of spontaneous forest development is necessary. A complete monitoring system has been developed including a computer package for analysis of long-term forest dynamics

  16. Crab: A Dashboard System for Monitoring Archiving Tasks

    Science.gov (United States)

    Bell, G.; Jenness, T.; Agarwal, A.

    2013-10-01

    In order to make the large number of cron jobs required to perform data archiving tasks at the Joint Astronomy Centre more manageable, we have designed and implemented a dashboard system for monitoring their progress. The status of all of the tasks can be monitored on the dashboard's web interface, and via consolidated notification emails.

  17. [Fetal ECG monitoring system based on MCU processing].

    Science.gov (United States)

    Hu, Gang; Chen, Wei; Xie, Xicheng; Zhang, Hao

    2004-12-01

    In order to monitor the fetus in labor, the signal characteristic from fetal scalp electrode is researched, An adaptation algorithm and a peak to peak detecting technology are adopted in signal processing, and an adaptation gain control method is used to eliminate disturber from base-line shift. A fetal ECG monitoring system is designed on the basis of C8051F020 MCU.

  18. Forest dynamics. Silvi-star: a comprehensive monitoring system.

    NARCIS (Netherlands)

    Koop, H.

    1989-01-01

    To learn about the interactions between individual trees and between trees and other forest organisms, long-term monitoring of spontaneous forest development is necessary. A complete monitoring system has been developed including a computer package for analysis of long-term forest dynamics observati

  19. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  20. B190 computer controlled radiation monitoring and safety interlock system

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, D L; Fields, W F; Gittins, D E; Roberts, M L

    1998-08-01

    The Center for Accelerator Mass Spectrometry (CAMS) in the Earth and Environmental Sciences Directorate at Lawrence Livermore National Laboratory (LLNL) operates two accelerators and is in the process of installing two new additional accelerators in support of a variety of basic and applied measurement programs. To monitor the radiation environment in the facility in which these accelerators are located and to terminate accelerator operations if predetermined radiation levels are exceeded, an updated computer controlled radiation monitoring system has been installed. This new system also monitors various machine safety interlocks and again terminates accelerator operations if machine interlocks are broken. This new system replaces an older system that was originally installed in 1988. This paper describes the updated B190 computer controlled radiation monitoring and safety interlock system.

  1. Selecting a clinical intervention documentation system for an academic setting.

    Science.gov (United States)

    Fox, Brent I; Andrus, Miranda; Hester, E Kelly; Byrd, Debbie C

    2011-03-10

    Pharmacists' clinical interventions have been the subject of a substantial body of literature that focuses on the process and outcomes of establishing an intervention documentation program within the acute care setting. Few reports describe intervention documentation as a component of doctor of pharmacy (PharmD) programs; none describe the process of selecting an intervention documentation application to support the complete array of pharmacy practice and experiential sites. The process that a school of pharmacy followed to select and implement a school-wide intervention system to document the clinical and financial impact of an experiential program is described. Goals included finding a tool that allowed documentation from all experiential sites and the ability to assign dollar savings (hard and soft) to all documented interventions. The paper provides guidance for other colleges and schools of pharmacy in selecting a clinical intervention documentation system for program-wide use.

  2. Systems and method for lagrangian monitoring of flooding conditions

    KAUST Repository

    Claudel, Christian G.

    2015-12-17

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  3. Coal mine gas monitoring system based on wireless sensor network

    Institute of Scientific and Technical Information of China (English)

    WANG Jian; WANG Ru-lin; WANG Xue-min; SHEN Chuan-he

    2007-01-01

    Based on the nowadays'condition.it is urgent that the gas detection cable communication system must be replaced by the wireless communication systems.The wireless sensors distributed in the environment can achieve the intelligent gas monitoring system.Apply with multilayer data fuse to design working tactics,and import the artificial neural networks to analyze detecting result.The wireless sensors system communicates with the controI center through the optical fiber cable.All the gas sensor nodes distributed in coal mine are combined into an intelligent,flexible structure wireless network system.forming coal mine gas monitoring system based on wireless sensor network.

  4. System And Method For Monitoring Traffic While Preserving Personal Privacy

    KAUST Repository

    Canepa, Edward

    2015-08-06

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  5. Real-time infrared test set: system design and development

    Science.gov (United States)

    Johnson, R. Barry; Martin, Diehl H.; Chung, Ronald; Geist, Jon C.; Burrell, Jack O.; Slemp, Jim L.; Umstead, Jeffrey R.; Mann, Allen; Marlin, H. Ronald; Bates, Richard L.; Sweet, Miles H.; Williams, Donald N.; Carlson, Rowena M.; Gaitan, Michael; Marshall, Janet C.; Mulford, Charles D.; Zakar, Eugene S.; Zeto, Robert J.; Olson, Russ; Perkins, Gordon C.

    1997-07-01

    During the past several years, the technology for designing and fabricating thermal pixel arrays (TPAs) using silicon micromachined CMOS devices has been developed adequately to support the development of a real-time infrared test set (RTIR) for sensors and seekers. The TPA is a custom application-specific integrated circuit device that is fabricated using a low-cost commercial CMOS process. The system architecture and development of the initial RTIR Test Set is described. The RTIR is a compact, self-contained test instrument that is intended for test and evaluation of infrared systems in the field. In addition to the TPA, the RTIR contains projection optics and electronics which drive the TPA, provide TPA nonuniformity compensation, data translation, data transformation, and user interface. The RTIR can display internal test patterns (static and dynamic), external digital video data, and NTSC video. The initial RTIR unit incorporates a 64 X 64 TPA to provide flickerless infrared scenes at 30 frames per second. Additional TPAs are under development with formats of 128 X 128, 256 X 256, and 512 X 512 pixels.

  6. An Integrated Health Monitoring System for Fission Surface Power

    Science.gov (United States)

    Hashemian, H. M.; Shumaker, B. D.; McCulley, J. R.; Morton, G. W.

    Based on such criteria as safety and mission success, programmatic risk, affordability, and extensibility/flexibility, the National Aeronautics and Space Administration (NASA) has chosen fission surface power (FSP) as the primary energy source for building a sustained human presence on the Moon, exploring Mars, and extremely long-duration space missions. The current benchmark FSP system has a mission life of at least 8 years during which time there is no opportunity for repair, sensor calibrations, or periodic maintenance tasks that are normally performed on terrestrial-based nuclear power plants during scheduled outages. Current technology relies heavily on real-time human interaction, monitoring and control. However; due to the long communication times between the Earth and Moon, or Mars, real-time human control is not possible, resulting in a critical need to develop autonomous health monitoring technology for FSP systems.This paper describes the design and development of an autonomous health monitoring system that will (1) provide on-line calibration monitoring, (2) reduce uncertainties in sensor measurements, and (3) provide sensor validation and fault detection capabilities for the control systems of various FSP subsystems. The health monitoring system design integrates a number of signal processing algorithms and techniques such as cross-calibration, empirical modeling using neural networks, and physical modeling under a modular signal processing platform that will enable robust sensor and system monitoring without the need for human interaction. Prototypes of the health monitoring system have been tested and validated on data acquired from preliminary subsystem testing of NASA's FSP Technology Demonstration Unit (TDU) as well as simulated laboratory data. Results from this testing have demonstrated the utility and benefits that such autonomous health monitoring systems can provide to FSP subsystems and other potential applications within NASA such as launch

  7. The CARMA Monitor System (CAM) - Transforming Cyclically Collected Telemetry into a Linear Stream

    Science.gov (United States)

    Amarnath, N. S.; Scott, S. L.; Kraybill, J. C.; Beard, A. D.; Daniel, P.; Gwon, C.; Hobbs, R.; Leitch, E.; Mehringer, D. M.; Plante, R.; Pound, M. W.; Rauch, K. P.; Teuben, P. J.

    2004-07-01

    The Combined Array for Research in Millimeter-wave Astronomy (CARMA) will be the combination of the BIMA, OVRO, and SZA millimeter arrays, at a new high elevation site (7200', 2200 m). With first light scheduled for 2005, CARMA will be the first heterogeneous millimeter array, combining antennas with diameters of 3.5, 6.1 and 10.4 meters. CARMA's monitoring system (CAM), is designed to collect monitor data periodically from a set of heterogenous systems and organize these monitor points hierarchically. It allows for the collection/collation of sampled values from arbitrary monitor points and the storage of such monitor point values in files and databases. Monitor points may be mapped to multiple hierarchies, for example, physical hierarchies like antennas, receivers, and drives, or logical hierarchies like sub-arrays and antennas. The monitor system was designed to accommodate monitor points associated with state machines, physical quantities (such as voltages), complex quantities (such as phases) and logical quantities like process health. It is also designed to help identify and isolate problems quickly, especially during integration at the new high site.

  8. Personnel reliability impact on petrochemical facilities monitoring system's failure skipping probability

    Science.gov (United States)

    Kostyukov, V. N.; Naumenko, A. P.

    2017-08-01

    The paper dwells upon urgent issues of evaluating impact of actions conducted by complex technological systems operators on their safe operation considering application of condition monitoring systems for elements and sub-systems of petrochemical production facilities. The main task for the research is to distinguish factors and criteria of monitoring system properties description, which would allow to evaluate impact of errors made by personnel on operation of real-time condition monitoring and diagnostic systems for machinery of petrochemical facilities, and find and objective criteria for monitoring system class, considering a human factor. On the basis of real-time condition monitoring concepts of sudden failure skipping risk, static and dynamic error, monitoring systems, one may solve a task of evaluation of impact that personnel's qualification has on monitoring system operation in terms of error in personnel or operators' actions while receiving information from monitoring systems and operating a technological system. Operator is considered as a part of the technological system. Although, personnel's behavior is usually a combination of the following parameters: input signal - information perceiving, reaction - decision making, response - decision implementing. Based on several researches on behavior of nuclear powers station operators in USA, Italy and other countries, as well as on researches conducted by Russian scientists, required data on operator's reliability were selected for analysis of operator's behavior at technological facilities diagnostics and monitoring systems. The calculations revealed that for the monitoring system selected as an example, the failure skipping risk for the set values of static (less than 0.01) and dynamic (less than 0.001) errors considering all related factors of data on reliability of information perception, decision-making, and reaction fulfilled is 0.037, in case when all the facilities and error probability are under

  9. Operation of International Monitoring System Network

    Science.gov (United States)

    Nikolova, Svetlana; Araujo, Fernando; Aktas, Kadircan; Malakhova, Marina; Otsuka, Riyo; Han, Dongmei; Assef, Thierry; Nava, Elisabetta; Mickevicius, Sigitas; Agrebi, Abdelouaheb

    2015-04-01

    The IMS is a globally distributed network of monitoring facilities using sensors from four technologies: seismic, hydroacoustic, infrasound and radionuclide. It is designed to detect the seismic and acoustic waves produced by nuclear test explosions and the subsequently released radioactive isotopes. Monitoring stations transmit their data to the IDC in Vienna, Austria, over a global private network known as the GCI. Since 2013, the data availability (DA) requirements for IMS stations account for quality of the data, meaning that in calculation of data availability data should be exclude if: - there is no input from sensor (SHI technology); - the signal consists of constant values (SHI technology); Even more strict are requirements for the DA of the radionuclide (particulate and noble gas) stations - received data have to be analyzed, reviewed and categorized by IDC analysts. In order to satisfy the strict data and network availability requirements of the IMS Network, the operation of the facilities and the GCI are managed by IDC Operations. Operations has following main functions: - to ensure proper operation and functioning of the stations; - to ensure proper operation and functioning of the GCI; - to ensure efficient management of the stations in IDC; - to provide network oversight and incident management. At the core of the IMS Network operations are a series of tools for: monitoring the stations' state of health and data quality, troubleshooting incidents, communicating with internal and external stakeholders, and reporting. The new requirements for data availability increased the importance of the raw data quality monitoring. This task is addressed by development of additional tools for easy and fast identifying problems in data acquisition, regular activities to check compliance of the station parameters with acquired data by scheduled calibration of the seismic network, review of the samples by certified radionuclide laboratories. The DA for the networks of

  10. Engineering considerations for corrosion monitoring of gas gathering pipeline systems

    Energy Technology Data Exchange (ETDEWEB)

    Braga, T.G.; Asperger, R.G.

    1987-01-01

    Proper corrosion monitoring of gas gathering pipelines requires a system review to determine the appropriate monitor locations and types of monitoring techniques. This paper develops and discusses a classification of conditions such as flow regime and gas composition. Also discussed are junction categories which, for corrosion monitoring, need to be considered from two points of view. The first is related to fluid flow in the line and the second is related corrosion inhibitor movement along the pipeline. The appropriate application of the various monitoring techniques such as coupons, hydrogen detectors, electrical resistance probe and linear polarization probes are discussed in relation to flow regime and gas composition. Problems caused by semi-conduction from iron sulfide are considered. Advantages and disadvantages of fluid gathering methods such as pots and flow-through drips are discussed in relation to their reliability as on-line monitoring locations.

  11. Design of smart neonatal health monitoring system using SMCC.

    Science.gov (United States)

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  12. Can wide consultation help with setting priorities for large-scale biodiversity monitoring programs?

    Directory of Open Access Journals (Sweden)

    Frédéric Boivin

    Full Text Available Climate and other global change phenomena affecting biodiversity require monitoring to track ecosystem changes and guide policy and management actions. Designing a biodiversity monitoring program is a difficult task that requires making decisions that often lack consensus due to budgetary constrains. As monitoring programs require long-term investment, they also require strong and continuing support from all interested parties. As such, stakeholder consultation is key to identify priorities and make sound design decisions that have as much support as possible. Here, we present the results of a consultation conducted to serve as an aid for designing a large-scale biodiversity monitoring program for the province of Québec (Canada. The consultation took the form of a survey with 13 discrete choices involving tradeoffs in respect to design priorities and 10 demographic questions (e.g., age, profession. The survey was sent to thousands of individuals having expected interests and knowledge about biodiversity and was completed by 621 participants. Overall, consensuses were few and it appeared difficult to create a design fulfilling the priorities of the majority. Most participants wanted 1 a monitoring design covering the entire territory and focusing on natural habitats; 2 a focus on species related to ecosystem services, on threatened and on invasive species. The only demographic characteristic that was related to the type of prioritization was the declared level of knowledge in biodiversity (null to high, but even then the influence was quite small.

  13. Wireless data management system for environmental monitoring in livestock buildings

    Directory of Open Access Journals (Sweden)

    James Gray

    2017-03-01

    Full Text Available The impact of air quality on the health, welfare and productivity of livestock needs to be considered, especially when livestock are kept in enclosed buildings. The monitoring of such environmental factors allows for the development of appropriate strategies to reduce detrimental effects of sub-optimal air quality on the respiratory health of both livestock and farmers. In 2009, an environmental monitoring system was designed, developed and tested that allowed for the monitoring of a number of airborne pollutants. One limitation of the system was the manual collection of logged data from each unit. This paper identifies limitations of the current environmental monitoring system and suggests a range of networking technologies that can be used to increase usability. Consideration is taken for the networking of environmental monitoring units, as well as the collection of recorded data. Furthermore, the design and development of a software system that is used to collate and store recorded environmental data from multiple farms is explored. In order to design such a system, simplified software engineering processes and methodologies have been utilised. The main steps taken in order to complete the project were requirements elicitation with clients, requirements analysis, system design, implementation and finally testing. The outcome of the project provided a potential prototype for improving the environmental monitoring system and analysis informing the benefit of the implementation.

  14. Vulnerability analysis for design of bridge health monitoring system

    Science.gov (United States)

    Sun, L. M.; Yu, G.

    2010-03-01

    The recent engineering implementation of health monitoring system for long span bridges show difficulties for precisely assessing structural physical condition as well as for accurately alarming on structural damages, although hundreds of sensors were installed on a structure and a great amount of data were collected from the monitoring system. The allocation of sensors and the alarming algorithm are still two of the most important tasks to be considered when designing the structural health monitoring system. Vulnerability, in its original meaning, is the system susceptibility to local damage. For a structural system, the vulnerability can thus be regarded as structural performance susceptibility to local damage of structure. The purpose of this study is to propose concepts and methods of structural vulnerability for determining monitoring components which are more vulnerable than others and the corresponding warning threshold once the damages occur. The structural vulnerability performances to various damage scenarios depend upon structural geometrical topology, loading pattern on the structure and the degradation of component performance. A two-parameters structural vulnerability evaluation method is proposed in this paper. The parameters are the damage consequence and the relative magnitude of the damage scenarios to the structural system, respectively. Structural vulnerability to various damage scenarios can be regarded as the tradeoff between the two parameters. Based on the results of structural vulnerability analysis, the limited structural information from health monitoring can be utilized efficiently. The approach of the design of bridge health monitoring system is illustrated for a cable-stayed bridge.

  15. Project W-420 Stack Monitoring system upgrades conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    TUCK, J.A.

    1998-11-06

    This document describes the scope, justification, conceptual design, and performance of Project W-420 stack monitoring system upgrades on six NESHAP-designated, Hanford Tank Farms ventilation exhaust stacks.

  16. Feed the Future Monitoring System Aggregate Data 2011-2014

    Data.gov (United States)

    US Agency for International Development — The Feed the Future Monitoring System (FTFMS) is part of an interagency effort to consolidate U.S. Government (USG) reporting on Feed the Future activities. FTFMS...

  17. Novel Real-Time Flight Envelope Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an aircraft flight envelope monitoring system that will provide real-time in-cockpit estimations of aircraft flight envelope boundaries,...

  18. Novel Real-Time Flight Envelope Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an aircraft flight envelope monitoring system that will provide real-time in-cockpit estimations of aircraft flight envelope boundaries....

  19. A Framework for Systematic Benchmarking of Monitoring and Diagnostic Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — In this paper, we present an architecture and a formal framework to be used for systematic benchmarking of monitoring and diagnostic systems and for producing...

  20. Project Design Concept for Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    MCGREW, D.L.

    2000-10-02

    This Project Design Concept represents operational requirements established for use in design the tank farm Monitoring and Control System. These upgrades are included within the scope of Project W-314, Tank Farm Restoration and Safe Operations.