Low-cost RFID-based palm oil monitoring system (PMS): First prototype
International Nuclear Information System (INIS)
Kiama, J W; Patrick, T H H; Raman, V
2014-01-01
Under collaboration with our local oil palm plantation enterprise, our research focuses on producing proof-of-concept by using RFID technology to monitor palm oil productivity. Passive RFID tags are used in the plantation field to uniquely identify each palm oil tree and their Fresh Fruit Bunches (FFB) production is collected and monitored by scanning the passive RFID tags using high frequency RFID scanners. This technology aims to convert the harvest data into digital information which can be processed and analyzed by PMS system and presented as informative outputs such as dynamic charts. This analyzed information is further used as input to a proprietary GIS system where it is mapped as color-coded spatial data which enables an accurate evaluation and monitoring of the overall plantation productivity
2010-04-01
... the “AASHTO Guidelines for Pavement Management Systems.” 1 1 AASHTO Guidelines for Pavement Management... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.106 PMS. An effective PMS for Federal-aid highways is a systematic...
International Nuclear Information System (INIS)
1998-01-01
During last 10 years the modern system of radiological pollution monitoring has been developed in Poland. At the beginning it was composed of ASS-500 stations. At the end of 1995 five automatic PMS stations have been installed as the result of the collaboration between Polish and Danish governments. Several stations of both types were include later. The system is coordinated by Central Laboratory for Radiological Protection. The report reviews the meeting dedicated to problems and future developments of the system
23 CFR 973.208 - Indian lands pavement management system (PMS).
2010-04-01
... 23 Highways 1 2010-04-01 2010-04-01 false Indian lands pavement management system (PMS). 973.208... PROGRAM Bureau of Indian Affairs Management Systems § 973.208 Indian lands pavement management system (PMS... concepts described in the AASHTO's “Pavement Management Guide.” 1 1 “Pavement Management Guide,” AASHTO...
Directory of Open Access Journals (Sweden)
Myeda N.E.
2014-01-01
Full Text Available Performance Measurement System (PMS is an effective performance measurement tool and technique that is being widely implemented in the global industries. Literature has suggested the significant contributions of its implementation in enhancing the strategic service delivery and performance. However, there is little study undertaken to explore the PMS implementation in Facilities Management (FM industry, particularly focusing on Malaysia. This study explores the PMS practice among FM practitioners and their knowledge in Performance Measurement (PM generally. Findings from this study also proposed the 20 contributing factors that the FM practitioners believed are the barriers in implementing PMS. This research also suggests the future research opportunities in developing a PMS framework that can be used as guidance for FM service delivery in Malaysia.
Hochgesang, Mindy; Zamudio-Haas, Sophia; Moran, Lissa; Nhampossa, Leopoldo; Packel, Laura; Leslie, Hannah; Richards, Janise; Shade, Starley B
2017-01-01
The rapid scale-up of HIV care and treatment in resource-limited countries requires concurrent, rapid development of health information systems to support quality service delivery. Mozambique, a country with an 11.5% prevalence of HIV, has developed nation-wide patient monitoring systems (PMS) with standardized reporting tools, utilized by all HIV treatment providers in paper or electronic form. Evaluation of the initial implementation of PMS can inform and strengthen future development as the country moves towards a harmonized, sustainable health information system. This assessment was conducted in order to 1) characterize data collection and reporting processes and PMS resources available and 2) provide evidence-based recommendations for harmonization and sustainability of PMS. This baseline assessment of PMS was conducted with eight non-governmental organizations that supported the Ministry of Health to provide 90% of HIV care and treatment in Mozambique. The study team conducted structured and semi-structured surveys at 18 health facilities located in all 11 provinces. Seventy-nine staff were interviewed. Deductive a priori analytic categories guided analysis. Health facilities have implemented paper and electronic monitoring systems with varying success. Where in use, robust electronic PMS facilitate facility-level reporting of required indicators; improve ability to identify patients lost to follow-up; and support facility and patient management. Challenges to implementation of monitoring systems include a lack of national guidelines and norms for patient level HIS, variable system implementation and functionality, and limited human and infrastructure resources to maximize system functionality and information use. This initial assessment supports the need for national guidelines to harmonize, expand, and strengthen HIV-related health information systems. Recommendations may benefit other countries with similar epidemiologic and resource
Wernstedt, Annekatrin; Valtorta, Emanuele; Armelao, Franco; Togni, Roberto; Girlando, Salvatore; Baudis, Michael; Heinimann, Karl; Messiaen, Ludwine; Staehli, Noemie; Zschocke, Johannes; Marra, Giancarlo; Wimmer, Katharina
2012-09-01
Heterozygous PMS2 germline mutations are associated with Lynch syndrome. Up to one third of these mutations are genomic deletions. Their detection is complicated by a pseudogene (PMS2CL), which--owing to extensive interparalog sequence exchange--closely resembles PMS2 downstream of exon 12. A recently redesigned multiplex ligation-dependent probe amplification (MLPA) assay identifies PMS2 copy number alterations with improved reliability when used with reference DNAs containing equal numbers of PMS2- and PMS2CL-specific sequences. We selected eight such reference samples--all publicly available--and used them with this assay to study 13 patients with PMS2-defective colorectal tumors. Three presented deleterious alterations: an Alu-mediated exon deletion; a 125-kb deletion encompassing PMS2 and four additional genes (two with tumor-suppressing functions); and a novel deleterious hybrid PMS2 allele produced by recombination with crossover between PMS2 and PMS2CL, with the breakpoint in intron 10 (the most 5' breakpoint of its kind reported thus far). We discuss mechanisms that might generate this allele in different chromosomal configurations (and their diagnostic implications) and describe an allele-specific PCR assay that facilitates its detection. Our data indicate that the redesigned PMS2 MLPA assay is a valid first-line option. In our series, it identified roughly a quarter of all PMS2 mutations. Copyright © 2012 Wiley Periodicals, Inc.
23 CFR 972.208 - Federal lands pavement management system (PMS).
2010-04-01
..., as a basic framework for a PMS: (1) A database and an ongoing program for the collection and maintenance of the inventory, inspection, cost, and supplemental data needed to support the PMS. The minimum... life (performance and remaining service life to be developed with time); and (iii) An investment...
23 CFR 970.208 - Federal lands pavement management system (PMS).
2010-04-01
... goals, policies, criteria, and needs using the following components, at a minimum, as a basic framework..., inspection, cost, and supplemental data needed to support the PMS. The minimum PMS database shall include: (i... life (performance and remaining service life to be developed with time); and (iii) An investment...
Xu, Zhiheng; Liu, Yucheng; Williams, Isaiah; Li, Yan; Qian, Fengyu; Zhang, Hui; Cai, Dingyi; Wang, Lei; Li, Baikun
2016-11-15
A paper-based multi-anode microbial fuel cell (PMMFC) integrated with power management system (PMS) was developed as a disposable self-support real-time "shock" biosensor for wastewater. PMMFCs were examined at three types of shocks (chromium, hypochlorite and acetate) in a batch-mode chamber, and exhibited various responses to shock types and concentrations. The power output of PMMFC sensor was four times as the carbon cloth (CC)-based MFCs, indicating the advantage of paper-based anode for bacterial adhesion. The power output was more sensitive than the voltage output under shocks, and thus preventing the false signals. The simulation of power harvest using PMS indicated that PMMFC could accomplish more frequent data transmission than single-anode MFCs (PSMFC) and CC anode MFCs (CCMMFC), making the self-support wastewater monitor and data transmission possible. Compared with traditional MFC sensors, PMMFCs integrated with PMS exhibit the distinct advantages of tight paper-packed structure, short acclimation period, high power output, and high sensitivity to a wide range of shocks, posing a great potential as "disposable self-support shock sensor" for real time in situ monitoring of wastewater quality. Copyright © 2016 Elsevier B.V. All rights reserved.
Wernstedt, Annekatrin; Valtorta, Emanuele; Armelao, Franco; Togni, Roberto; Girlando, Salvatore; Baudis, Michael; Heinimann, Karl; Messiaen, Ludwine; Staehli, Noemie; Zschocke, Johannes; Marra, Giancarlo; Wimmer, Katharina
2012-01-01
Heterozygous PMS2 germline mutations are associated with Lynch syndrome. Up to one third of these mutations are genomic deletions. Their detection is complicated by a pseudogene (PMS2CL), which – owing to extensive interparalog sequence exchange – closely resembles PMS2 downstream of exon 12. A recently redesigned multiplex ligation-dependent probe amplification (MLPA) assay identifies PMS2 copy number alterations with improved reliability when used with reference DNAs containing equal number...
Bulawa, Philip
2012-01-01
Different forms of the performance management system have been implemented in many countries for some years. As in other countries, in 1999 the government of Botswana took a decision to implement a performance management system (PMS) across the entire public service including schools. The government explained the purpose for which this reform was…
Energy Technology Data Exchange (ETDEWEB)
Jiwen, Long; Haiyan, Chen; Zhongyan, Meng
2003-05-25
Sr-substituted (2 mol%) xPMS-(1-x)(PZ-PT) compositions were investigated systematically as a function of PMS concentrations as well as Niobium (Nb) contents. X-ray diffraction (XRD) patterns show that phases shift from tetragonal phase to rhombohedral phase with the increase of PMS concentrations and with the increase of Nb-doping contents in PMS2. The compositions with x=0.05 (PMS2) was found to have superior piezoelectric properties. The properties of the PMS2 compositions were optimized by the Nb-doping contents of 0.1 mol% (d{sub 33}=450 pC N{sup -1}, K{sub p}=0.65, Q{sub m}=1210). The compositions of PMS2 and 0.1 mol% Nb-doped compositions of PMS2 are practically suitable for ultrasonic motor (USM) applications.
Ling, Li; Zhang, Dapeng; Fan, Chihhao; Shang, Chii
2017-11-01
A novel Fe(II)/citrate/UV/PMS process for degrading a model micropollutant, carbamazepine (CBZ), at a low Fe(II)/PMS ratio and neutral pH has been proposed in this study, and the mechanisms of radical generation in the system was explored. With a UV dose of 302.4 mJ/cm 2 , an initial pH of 7, and CBZ, PMS, Fe(II) and citrate at initial concentrations of 10, 100, 12 and 26 μM, respectively, the CBZ degradation efficiency reached 71% in 20 min in the Fe(II)/citrate/UV/PMS process, which was 4.7 times higher than that in either the citrate/UV/PMS or Fe(II)/citrate/PMS process. The enhanced CBZ degradation in the Fe(II)/citrate/UV/PMS process was mainly attributed to the continuous activation of PMS by the UV-catalyzed regenerated Fe(II) from a Fe(III)-citrate complex, [Fe 3 O(cit) 3 H 3 ] 2- , which not only maintained Fe(III) soluble at neutral pH, but also increased 6.6 and 2.6 times of its molar absorbance and quantum yield as compared to those of ionic Fe(III), respectively. In the Fe(II)/citrate/UV/PMS process, the SO 4 •- produced from the fast reaction between PMS and the initially-added Fe(II) contributed 11% of CBZ degradation. The PMS activation by the UV radiation and regenerated Fe(II) contributed additional 14% and 46% of CBZ removal, respectively. The low iron and citrate doses and the fast radical generation at neutral pH make the Fe(II)/citrate/UV/PMS process suitable for degrading recalcitrant organic compounds in potable water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Premenstrual Syndrome (PMS) FAQ
... relationships, you may have premenstrual dysphoric disorder (PMDD). PMDD is a severe type of PMS that affects a small percentage of women. Drugs ... selective serotonin reuptake inhibitors (SSRIs) can help treat PMDD in some women. ... depression. Can PMS be treated? If your symptoms are mild to ...
Smith, Catherine E.; Bowen, Nikki; Graham, William J.; Goellner, Eva M.; Srivatsan, Anjana; Kolodner, Richard D.
2015-01-01
Previous studies reported the reconstitution of an Mlh1-Pms1-independent 5′ nick-directed mismatch repair (MMR) reaction using Saccharomyces cerevisiae proteins. Here we describe the reconstitution of a mispair-dependent Mlh1-Pms1 endonuclease activation reaction requiring Msh2-Msh6 (or Msh2-Msh3), proliferating cell nuclear antigen (PCNA), and replication factor C (RFC) and a reconstituted Mlh1-Pms1-dependent 3′ nick-directed MMR reaction requiring Msh2-Msh6 (or Msh2-Msh3), exonuclease 1 (Exo1), replication protein A (RPA), RFC, PCNA, and DNA polymerase δ. Both reactions required Mg2+ and Mn2+ for optimal activity. The MMR reaction also required two reaction stages in which the first stage required incubation of Mlh1-Pms1 with substrate DNA, with or without Msh2-Msh6 (or Msh2-Msh3), PCNA, and RFC but did not require nicking of the substrate, followed by a second stage in which other proteins were added. Analysis of different mutant proteins demonstrated that both reactions required a functional Mlh1-Pms1 endonuclease active site, as well as mispair recognition and Mlh1-Pms1 recruitment by Msh2-Msh6 but not sliding clamp formation. Mutant Mlh1-Pms1 and PCNA proteins that were defective for Exo1-independent but not Exo1-dependent MMR in vivo were partially defective in the Mlh1-Pms1 endonuclease and MMR reactions, suggesting that both reactions reflect the activation of Mlh1-Pms1 seen in Exo1-independent MMR in vivo. The availability of this reconstituted MMR reaction should now make it possible to better study both Exo1-independent and Exo1-dependent MMR. PMID:26170454
Smith, Catherine E; Bowen, Nikki; Graham, William J; Goellner, Eva M; Srivatsan, Anjana; Kolodner, Richard D
2015-08-28
Previous studies reported the reconstitution of an Mlh1-Pms1-independent 5' nick-directed mismatch repair (MMR) reaction using Saccharomyces cerevisiae proteins. Here we describe the reconstitution of a mispair-dependent Mlh1-Pms1 endonuclease activation reaction requiring Msh2-Msh6 (or Msh2-Msh3), proliferating cell nuclear antigen (PCNA), and replication factor C (RFC) and a reconstituted Mlh1-Pms1-dependent 3' nick-directed MMR reaction requiring Msh2-Msh6 (or Msh2-Msh3), exonuclease 1 (Exo1), replication protein A (RPA), RFC, PCNA, and DNA polymerase δ. Both reactions required Mg(2+) and Mn(2+) for optimal activity. The MMR reaction also required two reaction stages in which the first stage required incubation of Mlh1-Pms1 with substrate DNA, with or without Msh2-Msh6 (or Msh2-Msh3), PCNA, and RFC but did not require nicking of the substrate, followed by a second stage in which other proteins were added. Analysis of different mutant proteins demonstrated that both reactions required a functional Mlh1-Pms1 endonuclease active site, as well as mispair recognition and Mlh1-Pms1 recruitment by Msh2-Msh6 but not sliding clamp formation. Mutant Mlh1-Pms1 and PCNA proteins that were defective for Exo1-independent but not Exo1-dependent MMR in vivo were partially defective in the Mlh1-Pms1 endonuclease and MMR reactions, suggesting that both reactions reflect the activation of Mlh1-Pms1 seen in Exo1-independent MMR in vivo. The availability of this reconstituted MMR reaction should now make it possible to better study both Exo1-independent and Exo1-dependent MMR. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
SiPMs characterization and selection for the DUNE far detector photon detection system
Sun, Y.; Maricic, J.
2016-01-01
The Deep Underground Neutrino Experiment (DUNE) together with the Long Baseline Neutrino Facility (LBNF) hosted at the Fermilab will provide a unique, world-leading program for the exploration of key questions at the forefront of neutrino physics and astrophysics. CP violation in neutrino flavor mixing is one of its most important potential discoveries. Additionally, the experiment will determine the neutrino mass hierarchy and precisely measure the neutrino mixing parameters which may potentially reveal new fundamental symmetries of nature. Moreover, the DUNE is also designed for the observation of nucleon decay and supernova burst neutrinos. The photon detection (PD) system in the DUNE far detector provides trigger for cosmic backgrounds, enhances supernova burst trigger efficiency and improves the energy resolution of the detector. The DUNE adopts the technology of liquid argon time projection chamber (LArTPC) that requires the PD sensors, silicon photomultipliers (SiPM), to be carefully chosen to not only work properly in LAr temperature, but also meet certain specifications for the life of the experiment. A comprehensive testing of SiPMs in cryostat is necessary since the datasheet provided by the manufactures in the market does not cover this temperature regime. This paper gives the detailed characterization results of SenSL C-Series 60035 SiPMs, including gain, dark count rate (DCR), cross-talk and after-pulse rate. Characteristic studies on SiPMs from other vendors are also discussed in order to avoid any potential problems associated with using a single source. Moreover, the results of the ongoing mechanical durability tests are shown for the current candidate, SenSL B/C-Series 60035 SiPMs.
Premenstrual syndrome (PMS among high school students
Directory of Open Access Journals (Sweden)
Buddhabunyakan N
2017-07-01
Full Text Available Nattapong Buddhabunyakan, Srinaree Kaewrudee, Chompilas Chongsomchai, Sukree Soontrapa, Woraluk Somboonporn, Jen Sothornwit Department of Obstetrics and Gynaecology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand Background: Premenstrual syndrome (PMS is a common health problem among adolescents.Objective: To assess the prevalence of PMS in Thai high school students.Materials and methods: This was a prospective study conducted among menstruating high school students in Khon Kaen, Thailand, from September to December, 2015. Participants were asked to prospectively complete an anonymous questionnaire, which included information about demographic data, menstrual patterns, and symptoms to be recorded on a daily calendar of premenstrual experiences according to the diagnostic criteria proposed by the American College of Obstetricians and Gynecologists. All of the data were prospectively recorded for 90 consecutive days.Results: Of the 399 participants, 289 (72.4% completed the self-report questionnaire. Eighty-six participants (29.8%; 95% CI, 24.5%–35.4% reported having PMS. The most common somatic and affective symptoms among participants with PMS were breast tenderness (74.4% and angry outbursts (97.7%. There were significant differences between the PMS and non-PMS groups, and PMS was associated with various problems related to educational activities, including lack of concentration and motivation, poor individual work performance, poor collaborative work performance, and low scores. However, there were no significant differences regarding interpersonal relationships between the PMS and non-PMS groups.Conclusions: PMS is a common menstrual disorder among Thai high school students. The most common symptoms reported in this study were angry outbursts and breast tenderness. Keywords: premenstrual symptoms, prevalence, association, high school students
Premenstrual Dysphoric Disorder (PMDD): Different from PMS?
... between premenstrual dysphoric disorder (PMDD) and premenstrual syndrome (PMS)? How is PMDD treated? Answers from Jacqueline M. Thielen, M.D. ... disabling extension of premenstrual syndrome (PMS). Although regular PMS and PMDD both have physical and emotional symptoms, PMDD causes ...
Leminen, Henri; Paavonen, Jorma
2013-01-01
The symptoms of premenstrual syndrome (PMS) and premenstrual dysphoric disorder (PMDD) significantly impair daily functioning. Symptoms occur in the late luteal phase. There must be a symptom-free interval between the end of menstruation and the time of ovulation. A two-month daily rating of symptoms is required for the diagnosis. The etiology is not well-known. Premenstrual disorders do not occur in anovulatory states. Hormonal therapy suppressing ovulation and selective serotonin reuptake inhibitors (SSRIs) are effective treatments. PMS and PMDD can be successfully managed in general practice.
International Nuclear Information System (INIS)
Williamson, M.S.; Game, J.C.; Fogel, S.
1985-01-01
The PMS1 mutants, isolated on the basis of sharply elevated meiotic prototroph frequencies for two closely linked HIS4 alleles, display pleiotropic phenotypes in meiotic and mitotic cells. Two isolates carrying recessive mutations in PMS1 were characterized. They identify a function required to maintain low postmeiotic segregation (PMS) frequencies at many heterozygous sites. In addition, they are mitotic mutators. In mutant diploids, spore viability is reduced, and among survivors, gene conversion and postmeiotic segregation frequencies are increased, but reciprocal exchange frequencies are not affected. The conversion event pattern is also dramatically changed in multiply marked regions in PMS1 homozygotes. The PMS1 locus maps near MET4 on chromosome XIV. The PMS1 gene may identify an excision-resynthesis long patch mismatch correction function or a function that facilitates correction tract elongation. The PMS1 gene product may also play an important role in spontaneous mitotic mutation avoidance and correction of mismatches in heteroduplex DNA formed during spontaneous and UV-induced mitotic recombination. Based on meiotic recombination models emphasizing mismatch correction in heteroduplex DNA intermediates, this interpretation is favored, but alternative interpretations involving longer recombination intermediates in the mutants are also considered
Advances in digital SiPMs and their application in biomedical imaging
Energy Technology Data Exchange (ETDEWEB)
Schaart, Dennis R., E-mail: d.r.schaart@tudelft.nl [Delft University of Technology, Faculty of Applied Sciences, Radiation Science and Technology, Mekelweg 15, 2629 JB Delft (Netherlands); Charbon, Edoardo [Delft University of Technology, Faculty of Electrical Engineering, Circuits and Systems, Mekelweg 4, 2628 CD Delft (Netherlands); Frach, Thomas [Philips Digital Photon Counting, Pauwelsstraße 17, 52074 Aachen (Germany); Schulz, Volkmar [Department for Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Germany and Philips Research Europe, Aachen (Germany)
2016-02-11
Similar to analog silicon photomultipliers (SiPMs), digital SiPMs (dSiPMs) essentially consist of an array of single-photon avalanche photodiodes (SPADs). Instead of a passive quench resistor, however, an active quenching circuit is locally integrated with each SPAD, making the sensor response faster and less sensitive to the gains of the individual SPADs. Moreover, additional circuits for the fully digital acquisition, processing, and readout of optical signals are integrated within the sensor. As a result, dSiPMs offer high photo-detection efficiency, high single-photon time resolution (SPTR), and high uniformity, as well as many practical advantages, such as a very compact form factor, low voltage operation, magnetic field compatibility, high stability of operation, low gain drift, and a high degree of scalability. At the same time, dSiPMs represent a new paradigm in low-level light sensing technology. That is, their fully digital operation makes them true photon counting devices, preserving at least partly the discrete spatio-temporal structure of the information embedded in the optical signal. This means that the operation of dSiPMs can be fully understood only in statistical terms, but also opens up novel possibilities for extracting information from the measured data. So far, the main driver behind the development of dSiPMs has been the detection of scintillation pulses in detectors for time-of-flight (TOF) positron emission tomography (PET). Several types of dSiPM have been developed in recent years. Moreover, first imaging devices based on dSiPMs have been realized by various groups. This review summarizes the main dSiPM concepts and technologies currently under development, provides an overview of the results obtained recently with dSiPMs-based PET and SPECT devices, and presents a critical outlook on the challenges and chances for dSiPMs in future radiomolecular imaging systems.
PMS2 mutations in childhood cancer.
De Vos, Michel; Hayward, Bruce E; Charlton, Ruth; Taylor, Graham R; Glaser, Adam W; Picton, Susan; Cole, Trevor R; Maher, Eamonn R; McKeown, Carole M E; Mann, Jill R; Yates, John R; Baralle, Diana; Rankin, Julia; Bonthron, David T; Sheridan, Eamonn
2006-03-01
Until recently, the PMS2 DNA mismatch repair gene has only rarely been implicated as a cancer susceptibility locus. New studies have shown, however, that earlier analyses of this gene have had technical limitations and also that the genetic behavior of mutant PMS2 alleles is unusual, in that, unlike MLH1 or MSH2 mutations, PMS2 mutations show low heterozygote penetrance. As a result, a dominantly inherited cancer predisposition has not been a feature reported in families with PMS2 mutations. Such families have instead been ascertained through childhood-onset cancers in homozygotes or through apparently sporadic colorectal cancer in heterozygotes. We present further information on the phenotype associated with homozygous PMS2 deficiency in 13 patients from six families of Pakistani origin living in the United Kingdom. This syndrome is characterized by café-au-lait skin pigmentation and a characteristic tumor spectrum, including leukemias, lymphomas, cerebral malignancies (such as supratentorial primitive neuroectodermal tumors, astrocytomas, and glioblastomas), and colorectal neoplasia with an onset in early adult life. We present evidence for a founder effect in five families, all of which carried the same R802-->X mutation (i.e., arginine-802 to stop) in PMS2. This cancer syndrome can be mistaken for neurofibromatosis type 1, with important management implications including the risk of the disorder occurring in siblings and the likelihood of tumor development in affected individuals.
Army Personnel Management System Study (PMS2). Volume II. Appendices.
1979-11-06
demonstrated desirability, some functions would be facilitated, costs need further study, and mobilization capabilities should be emphasized. PMS2 is basis for current reorganization planning within ODCSPER.
Smith, Catherine E; Mendillo, Marc L; Bowen, Nikki; Hombauer, Hans; Campbell, Christopher S; Desai, Arshad; Putnam, Christopher D; Kolodner, Richard D
2013-10-01
Lynch syndrome (hereditary nonpolypsis colorectal cancer or HNPCC) is a common cancer predisposition syndrome. Predisposition to cancer in this syndrome results from increased accumulation of mutations due to defective mismatch repair (MMR) caused by a mutation in one of the mismatch repair genes MLH1, MSH2, MSH6 or PMS2/scPMS1. To better understand the function of Mlh1-Pms1 in MMR, we used Saccharomyces cerevisiae to identify six pms1 mutations (pms1-G683E, pms1-C817R, pms1-C848S, pms1-H850R, pms1-H703A and pms1-E707A) that were weakly dominant in wild-type cells, which surprisingly caused a strong MMR defect when present on low copy plasmids in an exo1Δ mutant. Molecular modeling showed these mutations caused amino acid substitutions in the metal coordination pocket of the Pms1 endonuclease active site and biochemical studies showed that they inactivated the endonuclease activity. This model of Mlh1-Pms1 suggested that the Mlh1-FERC motif contributes to the endonuclease active site. Consistent with this, the mlh1-E767stp mutation caused both MMR and endonuclease defects similar to those caused by the dominant pms1 mutations whereas mutations affecting the predicted metal coordinating residue Mlh1-C769 had no effect. These studies establish that the Mlh1-Pms1 endonuclease is required for MMR in a previously uncharacterized Exo1-independent MMR pathway.
Directory of Open Access Journals (Sweden)
Catherine E Smith
2013-10-01
Full Text Available Lynch syndrome (hereditary nonpolypsis colorectal cancer or HNPCC is a common cancer predisposition syndrome. Predisposition to cancer in this syndrome results from increased accumulation of mutations due to defective mismatch repair (MMR caused by a mutation in one of the mismatch repair genes MLH1, MSH2, MSH6 or PMS2/scPMS1. To better understand the function of Mlh1-Pms1 in MMR, we used Saccharomyces cerevisiae to identify six pms1 mutations (pms1-G683E, pms1-C817R, pms1-C848S, pms1-H850R, pms1-H703A and pms1-E707A that were weakly dominant in wild-type cells, which surprisingly caused a strong MMR defect when present on low copy plasmids in an exo1Δ mutant. Molecular modeling showed these mutations caused amino acid substitutions in the metal coordination pocket of the Pms1 endonuclease active site and biochemical studies showed that they inactivated the endonuclease activity. This model of Mlh1-Pms1 suggested that the Mlh1-FERC motif contributes to the endonuclease active site. Consistent with this, the mlh1-E767stp mutation caused both MMR and endonuclease defects similar to those caused by the dominant pms1 mutations whereas mutations affecting the predicted metal coordinating residue Mlh1-C769 had no effect. These studies establish that the Mlh1-Pms1 endonuclease is required for MMR in a previously uncharacterized Exo1-independent MMR pathway.
Chronic periodontitis as an etiology of sleep disturbances and premenstrual syndrome (PMS
Directory of Open Access Journals (Sweden)
Haryono Utomo
2007-03-01
Full Text Available It is obvious that sleep disturbances may induced by acute pulpal or periodontal pain. Other causes of sleep disturbances which also termed as sleep dysfunction, or insomnia, according to the patient has to be treated by physician. Nevertheless, in a case report, surprisingly, periodontal treatment relieved sleep disturbances and premenstrual syndrome (PMS. Coincidentally, women also more vulnerable to sleep disturbances and periodontal disease. It is also interesting that the exact etiology of PMS is still unknown, and 80% women who suffered from PMS also experience sleep disturbances. Recently, there has been increasing numbers of literatures and evidence-based cases linking periodontal disease to systemic diseases. However, systemic effects of periodontal disease that lead to PMS which associated with sleep disturbances are rarely discussed. Several mechanisms had been proposed to involve in these symptoms: female sexual hormonal imbalance, stimulation of the hypothalamic-pituitary-adrenal axis (HPA-axis and neurogenic switching mechanism. In addition, as estrogen makes women more susceptible to stress, it worsen the symptoms. The glucocorticoid hormones synthesized upon stimulation of the HPA-axis, either by stress or pro-inflammatory cytokines, may disrupt the sleep-wake cycle; and also create estrogen dominance. The aim of this study is to propose the etiopathogenesis of PMS which associated with sleep disturbances that may be related to chronic periodontitis. Since in this case report scaling and curettage resulted in the disappearing of PMS and sleep disturbances; the conclusion is that chronic periodontal disease may act as one of the etiologies of PMS and sleep disturbance.
LADOTD pavement management system (PMS) for project level applications.
2011-06-01
To fully address the research needs described in the problem statement, the primary objective of this project is to develop guidelines that provide information on how network level PMS data can be used at a project level in activities of pavement eng...
van der Klift, Heleen M; Tops, Carli M J; Bik, Elsa C; Boogaard, Merel W; Borgstein, Anne-Marijke; Hansson, Kerstin B M; Ausems, Margreet G E M; Gomez Garcia, Encarna; Green, Andrew; Hes, Frederik J; Izatt, Louise; van Hest, Liselotte P; Alonso, Angel M; Vriends, Annette H J T; Wagner, Anja; van Zelst-Stams, Wendy A G; Vasen, Hans F A; Morreau, Hans; Devilee, Peter; Wijnen, Juul T
2010-05-01
Heterozygous mutations in PMS2 are involved in Lynch syndrome, whereas biallelic mutations are found in Constitutional mismatch repair-deficiency syndrome patients. Mutation detection is complicated by the occurrence of sequence exchange events between the duplicated regions of PMS2 and PMS2CL. We investigated the frequency of such events with a nonspecific polymerase chain reaction (PCR) strategy, co-amplifying both PMS2 and PMS2CL sequences. This allowed us to score ratios between gene and pseudogene-specific nucleotides at 29 PSV sites from exon 11 to the end of the gene. We found sequence transfer at all investigated PSVs from intron 12 to the 3' end of the gene in 4 to 52% of DNA samples. Overall, sequence exchange between PMS2 and PMS2CL was observed in 69% (83/120) of individuals. We demonstrate that mutation scanning with PMS2-specific PCR primers and MLPA probes, designed on PSVs, in the 3' duplicated region is unreliable, and present an RNA-based mutation detection strategy to improve reliability. Using this strategy, we found 19 different putative pathogenic PMS2 mutations. Four of these (21%) are lying in the region with frequent sequence transfer and are missed or called incorrectly as homozygous with several PSV-based mutation detection methods. (c) 2010 Wiley-Liss, Inc.
Army Personnel Management System Study (PMS2). Volume I. Main Report.
1979-11-06
demonstrated desirability, some functions would be facilitated, costs need further study, and mobilization capabilities should be emphasized. PMS2 is basis for current reorganization planning within ODCSPER.
Reevaluation of the PMS alarm set-points in OPR1000
International Nuclear Information System (INIS)
Roh, Kyung Ho; Yang, Sung Tae; Jung, Sung In
2011-01-01
In Optimized Power Reactor 1000 (OPR1000), the common alarm of the plant monitoring system (PMS), which is related to the channel-to-channel core protection calculator (CPC), experiences frequent deviations in the departure from nucleate boiling ratio (DNBR) and the local power density (LPD) between the middle of the cycle and the end of the cycle. Because the channel-to-channel CPC causes deviations in the values of the DNBR and LPD, the increase in the CPC input variables exceeds the alarm set-points. The CPC DNBR and LPD are defined as follows: Deviation = the average of four CPC channels of the LPD and DNBR minus the value of each CPC channel LPD and DNBR. In this paper, we report on a review by the Korea Hydro and Nuclear Power Co., Ltd. (KHNP) regarding the suitability of the alarm set-points for the channel-tochannel deviations of the CPC DNBR and LPD. The set-points were revaluated in light of operational experience and the case of Palo Verde (which is the reference model of OPR1000). The KHNP consequently revised the relevant procedures, as well as and the PMS alarm set-points, as part of its follow-up action
PMS2 involvement in patients suspected of Lynch syndrome.
Niessen, Renée C; Kleibeuker, Jan H; Westers, Helga; Jager, Paul O J; Rozeveld, Dennie; Bos, Krista K; Boersma-van Ek, Wytske; Hollema, Harry; Sijmons, Rolf H; Hofstra, Robert M W
2009-04-01
It is well-established that germline mutations in the mismatch repair genes MLH1, MSH2, and MSH6 cause Lynch syndrome. However, mutations in these three genes do not account for all Lynch syndrome (suspected) families. Recently, it was shown that germline mutations in another mismatch repair gene, PMS2, play a far more important role in Lynch syndrome than initially thought. To explore this further, we determined the prevalence of pathogenic germline PMS2 mutations in a series of Lynch syndrome-suspected patients. Ninety-seven patients who had early-onset microsatellite instable colorectal or endometrial cancer, or multiple Lynch syndrome-associated tumors and/or were from an Amsterdam Criteria II-positive family were selected for this study. These patients carried no pathogenic germline mutation in MLH1, MSH2, or MSH6. When available, tumors were investigated for immunohistochemical staining (IHC) for PMS2. PMS2 was screened in all patients by exon-by-exon sequencing. We identified four patients with a pathogenic PMS2 mutation (4%) among the 97 patients we selected. IHC of PMS2 was informative in one of the mutation carriers, and in this case, the tumor showed loss of PMS2 expression. In conclusion, our study confirms the finding of previous studies that PMS2 is more frequently involved in Lynch syndrome than originally expected.
PMS2 monoallelic mutation carriers: the known unknown.
Goodenberger, McKinsey L; Thomas, Brittany C; Riegert-Johnson, Douglas; Boland, C Richard; Plon, Sharon E; Clendenning, Mark; Win, Aung Ko; Senter, Leigha; Lipkin, Steven M; Stadler, Zsofia K; Macrae, Finlay A; Lynch, Henry T; Weitzel, Jeffrey N; de la Chapelle, Albert; Syngal, Sapna; Lynch, Patrick; Parry, Susan; Jenkins, Mark A; Gallinger, Steven; Holter, Spring; Aronson, Melyssa; Newcomb, Polly A; Burnett, Terrilea; Le Marchand, Loïc; Pichurin, Pavel; Hampel, Heather; Terdiman, Jonathan P; Lu, Karen H; Thibodeau, Stephen; Lindor, Noralane M
2016-01-01
Germ-line mutations in MLH1, MSH2, MSH6, and PMS2 have been shown to cause Lynch syndrome. The penetrance of the cancer and tumor spectrum has been repeatedly studied, and multiple professional societies have proposed clinical management guidelines for affected individuals. Several studies have demonstrated a reduced penetrance for monoallelic carriers of PMS2 mutations compared with the other mismatch repair (MMR) genes, but clinical management guidelines have largely proposed the same screening recommendations for all MMR gene carriers. The authors considered whether enough evidence existed to propose new screening guidelines specific to PMS2 mutation carriers with regard to age at onset and frequency of colonic screening. Published reports of PMS2 germ-line mutations were combined with unpublished cases from the authors' research registries and clinical practices, and a discussion of potential modification of cancer screening guidelines was pursued. A total of 234 monoallelic PMS2 mutation carriers from 170 families were included. Approximately 8% of those with colorectal cancer (CRC) were diagnosed before age 30, and each of these tumors presented on the left side of the colon. As it is currently unknown what causes the early onset of CRC in some families with monoallelic PMS2 germline mutations, the authors recommend against reducing cancer surveillance guidelines in families found having monoallelic PMS2 mutations in spite of the reduced penetrance.Genet Med 18 1, 13-19.
Klift, H.M. van der; Tops, C.M.; Bik, E.C.; Boogaard, M.W.; Borgstein, A.M.; Hansson, K.B.; Ausems, M.G.E.M.; Gomez Garcia, E.; Green, A.; Hes, F.J.; Izatt, L.; Hest, L.P. van; Alonso, A.M.; Vriends, A.H.; Wagner, A.; Zelst-Stams, W.A.G. van; Vasen, H.F.; Morreau, H.; Devilee, P.; Wijnen, J.T.
2010-01-01
Heterozygous mutations in PMS2 are involved in Lynch syndrome, whereas biallelic mutations are found in Constitutional mismatch repair-deficiency syndrome patients. Mutation detection is complicated by the occurrence of sequence exchange events between the duplicated regions of PMS2 and PMS2CL. We
Wang, Wen-Chung; Lee, Ya-Ting; Lai, Yen-Chein
2017-03-27
Granulosa cell tumors are rare ovarian malignancies. Their characteristics include unpredictable indolent growth with malignant potential and late recurrence. Approximately 95% are of adult type. Recent molecular studies have characterized the FOXL2 402C > G mutation in adult granulosa cell tumor. Our previous case report showed that unique FOXL2 402C > G mutation and defective DNA mismatch repair system are associated with the development of adult granulosa cell tumor. In this study, the DNA sequences of four genes, MSH2, MLH1, MSH6, and PMS2, in the DNA mismatch repair system were determined via direct sequencing to elucidate the exact mechanism for the development of this granulosa cell tumor. The results showed that two missense germline mutations, T485K and N775L, inactivate the PMS2 gene. The results of this case study indicated that although FOXL2 402C > G mutation determines the development of granulosa cell tumor, PMS2 mutation may be the initial driver of carcinogenesis. Immunohistochemistry-based tumor testing for mismatch repair gene expression may be necessary for granulosa cell tumors to determine their malignant potential or if they are part of Lynch syndrome.
[Inactivation of PMS2 gene by promoter methylation in nasopharyngeal carcinoma].
Ni, H F; Jiang, B; Zhou, Z; Li, Y; Yuan, X Y; Cao, X L; Huang, G W
2016-11-23
Objective: To investigate the inactivation of PMS2 gene mediated by promoter methylation and its regulatory mechanism in nasopharyngeal carcinoma (NPC). Methods: Fifty-four NPC tissues, 16 normal nasopharyngeal epithelia (NNE), 5 NPC cell lines (CNE1, CNE2, TWO3, HNE1 and HONE1) and 1 normal nasopharyngeal epithelial cell line (NP69) were collected.Methylation-specific PCR (MSP) was used to detect the PMS2 promoter methylation, semi-quantitative reverse transcription PCR (qRT-PCR) was applied to determine its mRNA expression, and immunohistochemistry (IHC) was used to detect the protein expression of PMS2. The expressions of PMS2 mRNA in CNE1 and CNE2 cells before and after treated with methyltransferase inhibitor 5-aza-2-deoxycytidine were analyzed by qRT-PCR. The impact of methylation and demethylation on the mRNA expression of PMS2, and the association of mRNA and protein expression of PMS2 with clinicopathological features of nasopharyngeal cancer were analyzed. Results: Methylation of PMS2 gene was detected in all of the five NPC cell lines, but not in normal nasopharyngeal epithelial NP69 cells. The methylation rate of PMS2 gene in NPC tissues was 63% (34/54), significantly higher than that of the normal nasopharyngeal epithelia (0/16, P PMS2 mRNA and protein were significantly down-regulated in the 54 NPC tissues when compared with those in the 16 NNE tissues ( P PMS2 mRNA was restored in the CNE1 and CNE2 cells.However, the expressions of PMS2 mRNA and protein were not significantly correlated with patients' age, gender, TNM stage, histopathologic type or lymph node metastasis ( P >0.05 for all). Conclusions: Promoter methylation-mediated inactivation of PMS2 gene participates in carcinogenesis and development of NPC. PMS2 may be a candidate tumor suppressor in the treatment for patients with inactivation of PMS2 promoter methylation.
Clinical analysis of PMS2: mutation detection and avoidance of pseudogenes.
Vaughn, Cecily P; Robles, Jorge; Swensen, Jeffrey J; Miller, Christine E; Lyon, Elaine; Mao, Rong; Bayrak-Toydemir, Pinar; Samowitz, Wade S
2010-05-01
Germline mutation detection in PMS2, one of four mismatch repair genes associated with Lynch syndrome, is greatly complicated by the presence of numerous pseudogenes. We used a modification of a long-range PCR method to evaluate PMS2 in 145 clinical samples. This modification avoids potential interference from the pseudogene PMS2CL by utilizing a long-range product spanning exons 11-15, with the forward primer anchored in exon 10, an exon not shared by PMS2CL. Large deletions were identified by MLPA. Pathogenic PMS2 mutations were identified in 22 of 59 patients whose tumors showed isolated loss of PMS2 by immunohistochemistry (IHC), the IHC profile most commonly associated with a germline PMS2 mutation. Three additional patients with pathogenic mutations were identified from 53 samples without IHC data. Thirty-seven percent of the identified mutations were large deletions encompassing one or more exons. In 27 patients whose tumors showed absence of either another protein or combination of proteins, no pathogenic mutations were identified. We conclude that modified long-range PCR can be used to preferentially amplify the PMS2 gene and avoid pseudogene interference, thus providing a clinically useful germline analysis of PMS2. Our data also support the use of IHC screening to direct germline testing of PMS2. (c) 2010 Wiley-Liss, Inc.
23 CFR 971.208 - Federal lands pavement management system (PMS).
2010-04-01
... components, at a minimum, as a basic framework for a PMS: (1) A database and an ongoing program for the collection and maintenance of the inventory, inspection, cost, and supplemental data needed to support the... estimate of the remaining service life. Performance and remaining service life may be developed with time...
An intact Pms2 ATPase domain is not essential for male fertility.
Fischer, Jared M; Dudley, Sandra; Miller, Ashleigh J; Liskay, R Michael
2016-03-01
The DNA mismatch repair (MMR) machinery in mammals plays critical roles in both mutation avoidance and spermatogenesis. Meiotic analysis of knockout mice of two different MMR genes, Mlh1 and Mlh3, revealed both male and female infertility associated with a defect in meiotic crossing over. In contrast, another MMR gene knockout, Pms2 (Pms2(ko/ko)), which contained a deletion of a portion of the ATPase domain, produced animals that were male sterile but female fertile. However, the meiotic phenotype of Pms2(ko/ko) males was less clear-cut than for Mlh1- or Mlh3-deficient meiosis. More recently, we generated a different Pms2 mutant allele (Pms2(cre)), which results in deletion of the same portion of the ATPase domain. Surprisingly, Pms2(cre/cre) male mice were completely fertile, suggesting that the ATPase domain of Pms2 is not required for male fertility. To explore the difference in male fertility, we examined the Pms2 RNA and found that alternative splicing of the Pms2(cre) allele results in a predicted Pms2 containing the C-terminus, which contains the Mlh1-interaction domain, a possible candidate for stabilizing Mlh1 levels. To study further the basis of male fertility, we examined Mlh1 levels in testes and found that whereas Pms2 loss in Pms2(ko/ko) mice results in severely reduced levels of Mlh1 expression in the testes, Mlh1 levels in Pms2(cre/cre) testes were reduced to a lesser extent. Thus, we propose that a primary function of Pms2 during spermatogenesis is to stabilize Mlh1 levels prior to its critical crossing over function with Mlh3. Copyright © 2015 Elsevier B.V. All rights reserved.
Extensive gene conversion at the PMS2 DNA mismatch repair locus.
Hayward, Bruce E; De Vos, Michel; Valleley, Elizabeth M A; Charlton, Ruth S; Taylor, Graham R; Sheridan, Eamonn; Bonthron, David T
2007-05-01
Mutations of the PMS2 DNA repair gene predispose to a characteristic range of malignancies, with either childhood onset (when both alleles are mutated) or a partially penetrant adult onset (if heterozygous). These mutations have been difficult to detect, due to interference from a family of pseudogenes located on chromosome 7. One of these, the PMS2CL pseudogene, lies within a 100-kb inverted duplication (inv dup), 700 kb centromeric to PMS2 itself on 7p22. Here, we show that the reference genomic sequences cannot be relied upon to distinguish PMS2 from PMS2CL, because of sequence transfer between the two loci. The 7p22 inv dup occurred prior to the divergence of modern ape species (15 million years ago [Mya]), but has undergone extensive sequence homogenization. This process appears to be ongoing, since there is considerable allelic diversity within the duplicated region, much of it derived from sequence exchange between PMS2 and PMS2CL. This sequence diversity can result in both false-positive and false-negative mutation analysis at this locus. Great caution is still needed in the design and interpretation of PMS2 mutation screens. 2007 Wiley-Liss, Inc.
International Nuclear Information System (INIS)
Wu, Xin-yang; Wu, Xiao-Yue
2015-01-01
Phased Mission Systems (PMS) have several phases with different success criteria. Generally, traditional analytical methods need to make some assumptions when they are applied for reliability evaluation and analysis of complex PMS, for example, the components are non-repairable or components are not subjected to common cause failures (CCF). However, the evaluation and analysis results may be inapplicable when the assumptions do not agree with practical situation. In this article, we propose an extended object-oriented Petri net (EOOPN) model for mission reliability simulation of repairable PMS with CCFs. Based on object-oriented Petri net (OOPN), EOOPN defines four reusable sub-models to depict PMS at system, phase, or component levels respectively, logic transitions to depict complex components reliability logics in a more readable form, and broadcast place to transmit shared information among components synchronously. After extension, EOOPN could deal with repairable PMS with both external and internal CCFs conveniently. The mission reliability modelling, simulation and analysis using EOOPN are illustrated by a PMS example. The results demonstrate that the proposed EOOPN model is effective. - Highlights: • EOOPN model was effective in reliability simulation for repairable PMS with CCFs. • EOOPN had modular and hierarchical structure. • New elements of EOOPN made the modelling process more convenient and friendlier. • EOOPN had better model reusability and readability than other PNs
Phosphorylation-dependent signaling controls degradation of DNA mismatch repair protein PMS2.
Hinrichsen, Inga; Weßbecher, Isabel M; Huhn, Meik; Passmann, Sandra; Zeuzem, Stefan; Plotz, Guido; Biondi, Ricardo M; Brieger, Angela
2017-12-01
MutLα, a heterodimer consisting of MLH1 and PMS2, plays an important role in DNA mismatch repair and has been shown to be additionally involved in several other important cellular mechanisms. Previous work indicated that AKT could modulate PMS2 stability by phosphorylation. Still, the mechanisms of regulation of MutLα remain unclear. The stability of MutLα subunits was investigated by transiently overexpression of wild type and mutant forms of MLH1 and PMS2 using immunoblotting for measuring the protein levels after treatment. We found that treatment with the cell-permeable serine/threonine phosphatase inhibitor, Calyculin, leads to degradation of PMS2 when MLH1 or its C-terminal domain is missing or if amino acids of MLH1 essential for PMS2 interaction are mutated. In addition, we discovered that the C-terminal tail of PMS2 is relevant for this Calyculin-dependent degradation. A direct involvement of AKT, which was previously described to be responsible for PMS2 degradation, could not be detected. The multi-kinase inhibitor Sorafenib, in contrast, was able to avoid the degradation of PMS2 which postulates that cellular phosphorylation is involved in this process. Together, we show that pharmacologically induced phosphorylation by Calyculin can induce the selective proteasome-dependent degradation of PMS2 but not of MLH1 and that the PMS2 degradation could be blocked by Sorafenib treatment. Curiously, the C-terminal Lynch Syndrome-variants MLH1 L749P and MLH1 Y750X make PMS2 prone to Calyculin induced degradation. Therefore, we conclude that the specific degradation of PMS2 may represent a new mechanism to regulate MutLα. © 2017 Wiley Periodicals, Inc.
Imaging with SiPMs in noble-gas detectors
International Nuclear Information System (INIS)
Yahlali, N; González, K; Fernandes, L M P; Garcia, A N C; Soriano, A
2013-01-01
Silicon photomultipliers (SiPMs) are photosensors widely used for imaging in a variety of high energy and nuclear physics experiments. In noble-gas detectors for double-beta decay and dark matter experiments, SiPMs are attractive photosensors for imaging. However they are insensitive to the VUV scintillation emitted by the noble gases (xenon and argon). This difficulty is overcome in the NEXT experiment by coating the SiPMs with tetraphenyl butadiene (TPB) to convert the VUV light into visible light. TPB requires stringent storage and operational conditions to prevent its degradation by environmental agents. The development of UV sensitive SiPMs is thus of utmost interest for experiments using electroluminescence of noble-gas detectors. It is in particular an important issue for a robust and background free ββ0ν experiment with xenon gas aimed by NEXT. The photon detection efficiency (PDE) of UV-enhanced SiPMs provided by Hamamatsu was determined for light in the range 250–500 nm. The PDE of standard SiPMs of the same model (S10362-33-50C), coated and non-coated with TPB, was also determined for comparison. In the UV range 250–350 nm, the PDE of the standard SiPM is shown to decrease strongly, down to about 3%. The UV-enhanced SiPM without window is shown to have the maximum PDE of 44% at 325 nm and 30% at 250 nm. The PDE of the UV-enhanced SiPM with silicon resin window has a similar trend in the UV range, although it is about 30% lower. The TPB-coated SiPM has shown to have about 6 times higher PDE than the non-coated SiPM in the range 250–315 nm. This is however below the performance of the UV-enhanced prototypes in the same wavelength range. Imaging in noble-gas detectors using UV-enhanced SiPMs is discussed.
Colorectal Carcinomas With Isolated Loss of PMS2 Staining by Immunohistochemistry.
Alpert, Lindsay; Pai, Reetesh K; Srivastava, Amitabh; McKinnon, Wendy; Wilcox, Rebecca; Yantiss, Rhonda K; Arcega, Ramir; Wang, Hanlin L; Robert, Marie E; Liu, Xiuli; Pai, Rish K; Zhao, Lei; Westerhoff, Maria; Hampel, Heather; Kupfer, Sonia; Setia, Namrata; Xiao, Shu-Yuan; Hart, John; Frankel, Wendy L
2018-04-01
- Isolated loss of PMS2 staining is an uncommon immunophenotype in colorectal carcinomas, accounting for approximately 4% of tumors with microsatellite instability. Limited information regarding these tumors is available in the literature. - To compare the clinicopathologic features of colorectal carcinomas with isolated PMS2 loss by immunohistochemistry to those with other forms of mismatch repair deficiency. - Ninety-three colorectal carcinomas with isolated PMS2 loss by immunohistochemistry and 193 with other forms of mismatch repair deficiency were identified. Forty (43%) of the isolated PMS2 loss cases and 35 control cases (18%) had a known germline mutation or a clinical diagnosis of Lynch syndrome. - Overall, isolated PMS2-loss tumors occurred in significantly younger patients ( P PMS2-loss group also exhibited increased odds of disease-specific death (odds ratio [OR], 3.09; 95% CI, 1.41-6.85; P = .007). When the analysis was restricted to germline mutation/Lynch syndrome cases and controls, no significant differences were detected for age, sex, tumor location, tumor grade, histologic features, or distant metastases, although a trend toward increased odds of disease-specific death in the isolated PMS2-loss group was evident (OR, 3.87; 95% CI, 0.89-27.04; P = .10). - Unusual clinicopathologic features observed in colorectal carcinomas with isolated PMS2 loss are likely related to the high proportion of cases caused by germline mutations. Isolated PMS2-loss tumors may demonstrate more aggressive behavior than other tumors with microsatellite instability, but larger studies are needed to investigate that possibility further.
The New Jersey Performance Management System: A State System and Uses of Simple Measures.
Kamis-Gould, Edna
1987-01-01
The New Jersey Performance Management System (PMS) is a major mechanism used by the leadership of the New Jersey Division of Mental Health and Hospitals to contract for, monitor, and manage community mental health services. This paper describes PMS, its components, implementation, and limitations. (Author/LMO)
Avoidance of pseudogene interference in the detection of 3' deletions in PMS2.
Vaughn, Cecily P; Hart, Kimberly J; Samowitz, Wade S; Swensen, Jeffrey J
2011-09-01
Lynch syndrome is characterized by mutations in the mismatch repair genes MLH1, MSH2, MSH6, and PMS2. In PMS2, detection of mutations is confounded by numerous pseudogenes. Detection of 3' deletions is particularly complicated by the pseudogene PMS2CL, which has strong similarity to PMS2 exons 9 and 11-15, due to extensive gene conversion. A newly designed multiplex ligation-dependent probe amplification (MLPA) kit incorporates probes for variants found in both PMS2 and PMS2CL. This provides detection of deletions, but does not allow localization of deletions to the gene or pseudogene. To address this, we have developed a methodology incorporating reference samples with known copy numbers of variants, and paired MLPA results with sequencing of PMS2 and PMS2CL. We tested a subset of clinically indicated samples for which mutations were either unidentified or not fully characterized using existing methods. We identified eight unrelated patients with deletions encompassing exons 9-15, 11-15, 13-15, 14-15, and 15. By incorporating specific, characterized reference samples and sequencing the gene and pseudogene it is possible to identify deletions in this region of PMS2 and provide clinically relevant results. This methodology represents a significant advance in the diagnosis of patients with Lynch syndrome caused by PMS2 mutations. © 2011 Wiley-Liss, Inc.
The clinical phenotype of Lynch syndrome due to germline PMS2 mutations
Senter, Leigha; Clendenning, Mark; Sotamaa, Kaisa; Hampel, Heather; Green, Jane; Potter, John D.; Lindblom, Annika; Lagerstedt, Kristina; Thibodeau, Stephen N.; Lindor, Noralane M.; Young, Joanne; Winship, Ingrid; Dowty, James G.; White, Darren M.; Hopper, John L.; Baglietto, Laura; Jenkins, Mark A.; de la Chapelle, Albert
2009-01-01
Background and Aims Although the clinical phenotype of Lynch syndrome (also known as Hereditary Nonpolyposis Colorectal Cancer) has been well described, little is known about disease in PMS2 mutation carriers. Now that mutation detection methods can discern mutations in PMS2 from mutations in its pseudogenes, more mutation carriers have been identified. Information about the clinical significance of PMS2 mutations is crucial for appropriate counseling. Here, we report the clinical characteristics of a large series of PMS2 mutation carriers. Methods We performed PMS2 mutation analysis using long range PCR and MLPA for 99 probands diagnosed with Lynch syndrome-associated tumors showing isolated loss of PMS2 by immunohistochemistry. Penetrance was calculated using a modified segregation analysis adjusting for ascertainment. Results Germline PMS2 mutations were detected in 62% of probands (n = 55 monoallelic; 6 biallelic). Among families with monoallelic PMS2 mutations, 65.5% met revised Bethesda guidelines. Compared with the general population, in mutation carriers, the incidence of colorectal cancer was 5.2 fold higher and the incidence of endometrial cancer was 7.5 fold higher. In North America, this translates to a cumulative cancer risk to age 70 of 15–20% for colorectal cancer, 15% for endometrial cancer, and 25–32% for any Lynch syndrome-associated cancer. No elevated risk for non-Lynch syndrome-associated cancers was observed. Conclusions PMS2 mutations contribute significantly to Lynch syndrome but the penetrance for monoallelic mutation carriers appears to be lower than that for the other mismatch repair genes. Modified counseling and cancer surveillance guidelines for PMS2 mutation carriers are proposed. PMID:18602922
van Oers, Johanna M M; Roa, Sergio; Werling, Uwe; Liu, Yiyong; Genschel, Jochen; Hou, Harry; Sellers, Rani S; Modrich, Paul; Scharff, Matthew D; Edelmann, Winfried
2010-07-27
The DNA mismatch repair protein PMS2 was recently found to encode a novel endonuclease activity. To determine the biological functions of this activity in mammals, we generated endonuclease-deficient Pms2E702K knock-in mice. Pms2EK/EK mice displayed increased genomic mutation rates and a strong cancer predisposition. In addition, class switch recombination, but not somatic hypermutation, was impaired in Pms2EK/EK B cells, indicating a specific role in Ig diversity. In contrast to Pms2-/- mice, Pms2EK/EK male mice were fertile, indicating that this activity is dispensable in spermatogenesis. Therefore, the PMS2 endonuclease activity has distinct biological functions and is essential for genome maintenance and tumor suppression.
Long-range PCR facilitates the identification of PMS2-specific mutations.
Clendenning, Mark; Hampel, Heather; LaJeunesse, Jennifer; Lindblom, Annika; Lockman, Jan; Nilbert, Mef; Senter, Leigha; Sotamaa, Kaisa; de la Chapelle, Albert
2006-05-01
Mutations within the DNA mismatch repair gene, "postmeiotic segregation increased 2" (PMS2), have been associated with a predisposition to hereditary nonpolyposis colorectal cancer (HNPCC; Lynch syndrome). The presence of a large family of highly homologous PMS2 pseudogenes has made previous attempts to sequence PMS2 very difficult. Here, we describe a novel method that utilizes long-range PCR as a way to preferentially amplify PMS2 and not the pseudogenes. A second, exon-specific, amplification from diluted long-range products enables us to obtain a clean sequence that shows no evidence of pseudogene contamination. This method has been used to screen a cohort of patients whose tumors were negative for the PMS2 protein by immunohistochemistry and had not shown any mutations within the MLH1 gene. Sequencing of the PMS2 gene from 30 colorectal and 11 endometrial cancer patients identified 10 novel sequence changes as well as 17 sequence changes that had previously been identified. In total, putative pathologic mutations were detected in 11 of the 41 families. Among these were five novel mutations, c.705+1G>T, c.736_741del6ins11, c.862_863del, c.1688G>T, and c.2007-1G>A. We conclude that PMS2 mutation detection in selected Lynch syndrome and Lynch syndrome-like patients is both feasible and desirable. Published 2006 Wiley-Liss, Inc.
Lynch Syndrome Caused by Germline PMS2 Mutations: Delineating the Cancer Risk
ten Broeke, Sanne W.; Brohet, Richard M.; Tops, Carli M.; van der Klift, Heleen M.; Velthuizen, Mary E.; Bernstein, Inge; Capellá Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G. W.; Menko, Fred H.; Lindblom, Annika; Mensenkamp, Arjen R.; Moller, Pal; van Os, Theo A.; Rahner, Nils; Redeker, Bert J. W.; Sijmons, Rolf H.; Spruijt, Liesbeth; Suerink, Manon; Vos, Yvonne J.; Wagner, Anja; Hes, Frederik J.; Vasen, Hans F.; Nielsen, Maartje; Wijnen, Juul T.
2015-01-01
Purpose The clinical consequences of PMS2 germline mutations are poorly understood compared with other Lynch-associated mismatch repair gene (MMR) mutations. The aim of this European cohort study was to define the cancer risk faced by PMS2 mutation carriers. Methods Data were collected from 98 PMS2
Lynch Syndrome Caused by Germline PMS2 Mutations : Delineating the Cancer Risk
ten Broeke, Sanne W.; Brohet, Richard M.; Tops, Carli M.; van der Klift, Heleen M.; Velthuizen, Mary E.; Bernstein, Inge; Capella Munar, Gabriel; Garcia, Encarna Gomez; Hoogerbrugge, Nicoline; Letteboer, Tom G. W.; Menko, Fred H.; Lindblom, Annika; Mensenkamp, Arjen R.; Moller, Pal; Van Os, Theo A.; Rahner, Nils; Redeker, Bert J. W.; Sijmons, Rolf H.; Spruijt, Liesbeth; Suerink, Manon; Vos, Yvonne J.; Wagner, Anja; Hes, Frederik J.; Vasen, Hans F.; Nielsen, Maartje; Wijnen, Juul T.
2015-01-01
Purpose The clinical consequences of PMS2 germline mutations are poorly understood compared with other Lynch-associated mismatch repair gene (MMR) mutations. The aim of this European cohort study was to define the cancer risk faced by PMS2 mutation carriers. Methods Data were collected from 98 PMS2
The clinical phenotype of Lynch syndrome due to germ-line PMS2 mutations.
Senter, Leigha; Clendenning, Mark; Sotamaa, Kaisa; Hampel, Heather; Green, Jane; Potter, John D; Lindblom, Annika; Lagerstedt, Kristina; Thibodeau, Stephen N; Lindor, Noralane M; Young, Joanne; Winship, Ingrid; Dowty, James G; White, Darren M; Hopper, John L; Baglietto, Laura; Jenkins, Mark A; de la Chapelle, Albert
2008-08-01
Although the clinical phenotype of Lynch syndrome (also known as hereditary nonpolyposis colorectal cancer) has been well described, little is known about disease in PMS2 mutation carriers. Now that mutation detection methods can discern mutations in PMS2 from mutations in its pseudogenes, more mutation carriers have been identified. Information about the clinical significance of PMS2 mutations is crucial for appropriate counseling. Here, we report the clinical characteristics of a large series of PMS2 mutation carriers. We performed PMS2 mutation analysis using long-range polymerase chain reaction and multiplex ligation-dependent probe amplification for 99 probands diagnosed with Lynch syndrome-associated tumors showing isolated loss of PMS2 by immunohistochemistry. Penetrance was calculated using a modified segregation analysis adjusting for ascertainment. Germ-line PMS2 mutations were detected in 62% of probands (n = 55 monoallelic; 6 biallelic). Among families with monoallelic PMS2 mutations, 65.5% met revised Bethesda guidelines. Compared with the general population, in mutation carriers, the incidence of colorectal cancer was 5.2-fold higher, and the incidence of endometrial cancer was 7.5-fold higher. In North America, this translates to a cumulative cancer risk to age 70 years of 15%-20% for colorectal cancer, 15% for endometrial cancer, and 25%-32% for any Lynch syndrome-associated cancer. No elevated risk for non-Lynch syndrome-associated cancers was observed. PMS2 mutations contribute significantly to Lynch syndrome, but the penetrance for monoallelic mutation carriers appears to be lower than that for the other mismatch repair genes. Modified counseling and cancer surveillance guidelines for PMS2 mutation carriers are proposed.
Microstrip silicon detectors of the monitoring and triggering systems in the E-161 experiment
International Nuclear Information System (INIS)
Bogolyubskij, M.Yu.; Kurchaninov, L.L.; Moiseev, A.M.; Semenov, P.A.; Leflat, A.K.; Sekhniaidze, G.G.
1991-01-01
A monitoring and triggering system based on microstrip silicon detectors (MSD) and fast-response low-noise electronics with the number of the readout channels equal to 896, is described. The PMS noise is ENC=25x10 3 e - with the signal integration time of 50 ns. The probability of registering a noise pulse by one channel during data readout cycle is not more than 2.5x10 -6 . The time resolution (FWHM) is (16±3) ns. 17 refs.; 7 figs
Lynch Syndrome Caused by Germline PMS2 Mutations
DEFF Research Database (Denmark)
Ten Broeke, Sanne W; Brohet, Richard M; Tops, Carli M
2015-01-01
PURPOSE: The clinical consequences of PMS2 germline mutations are poorly understood compared with other Lynch-associated mismatch repair gene (MMR) mutations. The aim of this European cohort study was to define the cancer risk faced by PMS2 mutation carriers. METHODS: Data were collected from 98...... PMS2 families ascertained from family cancer clinics that included a total of 2,548 family members and 377 proven mutation carriers. To adjust for potential ascertainment bias, a modified segregation analysis model was used to calculate colorectal cancer (CRC) and endometrial cancer (EC) risks....... Standardized incidence ratios (SIRs) were calculated to estimate risks for other Lynch syndrome-associated cancers. RESULTS: The cumulative risk (CR) of CRC for male mutation carriers by age 70 years was 19%. The CR among female carriers was 11% for CRC and 12% for EC. The mean age of CRC development was 52...
Characterization of FBK SiPMs under illumination with very fast light pulses
Energy Technology Data Exchange (ETDEWEB)
Tarolli, A., E-mail: tarolli@fbk.e [Fondazione Bruno Kessler (FBK), Trento (Italy); Dalla Betta, G.-F. [University of Trento and INFN, Trento (Italy); Melchiorri, M.; Piazza, A.; Pancheri, L.; Piemonte, C.; Zorzi, N. [Fondazione Bruno Kessler (FBK), Trento (Italy)
2010-05-21
A characterization of the response of SiPMs and SPADs produced at FBK-IRST Trento stimulated with fast laser pulses is presented. The tests were aimed at studying both the intrinsic timing proprieties (of SiPMs and SPADs) using the time-correlated single-photon counting technique and the dynamic range (of SiPMs). Measurements were carried out on devices with different cell size, namely, from 40x40 to 100x100 {mu}m{sup 2}. Concerning the timing resolution, all the devices exhibit a value less than 150 psec FWHM. The dynamic range of SiPMs shows a response linearity which is in line with the theory describing these devices.
Characterization of FBK SiPMs under illumination with very fast light pulses
International Nuclear Information System (INIS)
Tarolli, A.; Dalla Betta, G.-F.; Melchiorri, M.; Piazza, A.; Pancheri, L.; Piemonte, C.; Zorzi, N.
2010-01-01
A characterization of the response of SiPMs and SPADs produced at FBK-IRST Trento stimulated with fast laser pulses is presented. The tests were aimed at studying both the intrinsic timing proprieties (of SiPMs and SPADs) using the time-correlated single-photon counting technique and the dynamic range (of SiPMs). Measurements were carried out on devices with different cell size, namely, from 40x40 to 100x100 μm 2 . Concerning the timing resolution, all the devices exhibit a value less than 150 psec FWHM. The dynamic range of SiPMs shows a response linearity which is in line with the theory describing these devices.
Salgado, M; Steuer, P; Troncoso, E; Collins, M T
2013-12-27
Mycobacterium avium subsp. paratuberculosis (MAP) causes paratuberculosis, or Johne's disease, in animals. Diagnosis of MAP infection is challenging because of the pathogen's fastidious in vitro growth requirements and low-level intermittent shedding in feces during the preclinical phase of the infection. Detection of these "low-shedders" is important for effective control of paratuberculosis as these animals serve as sources of infection for susceptible calves. Magnetic separation technology, used in combination with culture or molecular methods for the isolation and detection of pathogenic bacteria, enhances the analytical sensitivity and specificity of detection methods. The aim of the present study was to evaluate peptide-mediated magnetic separation (PMS) capture technology coupled with IS900 PCR using the Roche real-time PCR system (PMS-PCR), in comparison with fecal culture using BACTEC-MGIT 960 system, for detection of MAP in bovine fecal samples. Among the 351 fecal samples 74.9% (263/351) were PMS-PCR positive while only 12.3% (43/351) were MGIT culture-positive (p=0.0001). All 43 MGIT culture-positive samples were also positive by PMS-PCR. Mean PMS-PCR crossing-point (Cp) values for the 13 fecal samples with the highest number of MAP, based on time to detection, (26.3) were significantly lower than for the 17 fecal samples with technology provided results in a shorter time and yielded a higher number of positive results than MGIT culture. Earlier and faster detection of animals shedding MAP by PMS-PCR should significantly strengthen control efforts for MAP-infected cattle herds by helping to limit infection transmission at earlier stages of the infection. Copyright © 2013 Elsevier B.V. All rights reserved.
Rosty, Christophe; Clendenning, Mark; Walsh, Michael D; Eriksen, Stine V; Southey, Melissa C; Winship, Ingrid M; Macrae, Finlay A; Boussioutas, Alex; Poplawski, Nicola K; Parry, Susan; Arnold, Julie; Young, Joanne P; Casey, Graham; Haile, Robert W; Gallinger, Steven; Le Marchand, Loïc; Newcomb, Polly A; Potter, John D; DeRycke, Melissa; Lindor, Noralane M; Thibodeau, Stephen N; Baron, John A; Win, Aung Ko; Hopper, John L; Jenkins, Mark A; Buchanan, Daniel D
2016-02-19
Immunohistochemistry for DNA mismatch repair proteins is used to screen for Lynch syndrome in individuals with colorectal carcinoma (CRC). Although solitary loss of PMS2 expression is indicative of carrying a germline mutation in PMS2, previous studies reported MLH1 mutation in some cases. We determined the prevalence of MLH1 germline mutations in a large cohort of individuals with a CRC demonstrating solitary loss of PMS2 expression. This cohort study included 88 individuals affected with a PMS2-deficient CRC from the Colon Cancer Family Registry Cohort. Germline PMS2 mutation analysis (long-range PCR and multiplex ligation-dependent probe amplification) was followed by MLH1 mutation testing (Sanger sequencing and multiplex ligation-dependent probe amplification). Of the 66 individuals with complete mutation screening, we identified a pathogenic PMS2 mutation in 49 (74%), a pathogenic MLH1 mutation in 8 (12%) and a MLH1 variant of uncertain clinical significance predicted to be damaging by in silico analysis in 3 (4%); 6 (9%) carried variants likely to have no clinical significance. Missense point mutations accounted for most alterations (83%; 9/11) in MLH1. The MLH1 c.113A> G p.Asn38Ser mutation was found in 2 related individuals. One individual who carried the MLH1 intronic mutation c.677+3A>G p.Gln197Argfs*8 leading to the skipping of exon 8, developed 2 tumours, both of which retained MLH1 expression. A substantial proportion of CRCs with solitary loss of PMS2 expression are associated with a deleterious MLH1 germline mutation supporting the screening for MLH1 in individuals with tumours of this immunophenotype, when no PMS2 mutation has been identified. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A case of early onset rectal cancer of Lynch syndrome with a novel deleterious PMS2 mutation.
Nomura, Sachio; Fujimoto, Yoshiya; Yamamoto, Noriko; Sato, Yuri; Ashihara, Yuumi; Kita, Mizuho; Yamaguchi, Junya; Ishikawa, Yuichi; Ueno, Masashi; Arai, Masami
2015-10-01
Heterozygous deleterious mutation of the PMS2 gene is a cause of Lynch syndrome, an autosomal dominant cancer disease. However, the frequency of PMS2 mutation is rare compared with that of the other causative genes; MSH2, MLH1 and MSH6. PMS2 mutation has so far only been reported once from a Japanese facility. Detection of PMS2 mutation is relatively complicated due to the existence of 15 highly homologous pseudogenes, and its gene conversion event with the pseudogene PMS2CL. Therefore, for PMS2 mutation analysis, it is crucial to clearly distinguish PMS2 from its pseudogenes. We report here a novel deleterious 11 bp deletion mutation of exon 11 of PMS2 distinguished from PMS2CL in a 34-year-old Japanese female with rectal cancer. PMS2 mutated at c.1492del11 results in a truncated 500 amino acid protein rather than the wild-type protein of 862 amino acids. This is supported by the fact that, although there is usually concordance between MLH1 and PMS2 expression, cells were immunohistochemically positive for MLH1, whereas PMS2 could not be immunohistochemically stained using an anti-C-terminal PMS2 antibody, or effective PMS2 mRNA degradation with NMD caused by the frameshift mutation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
International Nuclear Information System (INIS)
Jashi, K.B.; Ashok Kumar, A.; Pandaram, P.
2018-01-01
Personnel Monitoring Services (PMS) at Thermoluminescent Dosimeter (TLD) laboratory, Kudankulam Nuclear Power Project (KKNPP) involve monitoring of about 1500 radiation workers of KKNPP for external radiation exposure on monthly basis. Quality assurance in PMS provides an overall estimate of accuracy which depends not only upon the dosimeter quality and reader performance but also on data interpretation, applicable software and the system. Therefore it measures the effectiveness of quality control mechanism. Blind test is an effective tool to check the performance of the processor without their knowledge during routine processing of the service cards
Effectiveness of Group Cognitive-Behavioral Therapy on Symptoms of Premenstrual Syndrome (PMS) .
Maddineshat, Maryam; Keyvanloo, Sodabe; Lashkardoost, Hossein; Arki, Mina; Tabatabaeichehr, Mahbubeh
2016-01-01
Standards of care and treatment of premenstrual syndrome (PMS) vary. Non-drug psychosocial intervention therapy is recommended for women with any kind of discomfort or distress caused by PMS. The current study examined the effectiveness of group cognitive-behavioral therapy on the symptoms of PMS at a girls' dormitory of North Khorasan University of Medical Sciences. In this quasi-experimental study, 32 female students with PMS who were majoring in nursing and midwifery and residing in the dormitory were selected using the convenience sampling method and were assigned to experimental and control groups. The Standardized Premenstrual Symptoms Screening Tool was used as the research tool. Eight sessions of cognitive-behavioral group therapy were held for the students Results: There was a significant difference in psychological symptoms before and after cognitive-behavioral therapy (p=0.012). Furthermore, cognitive-behavioral therapy was effective on social interferences caused by PMS symptoms (p=0.012). Group cognitive-behavioral therapy effectively alleviates PMS symptoms in female college students..
The frequency of previously undetectable deletions involving 3' Exons of the PMS2 gene.
Vaughn, Cecily P; Baker, Christine L; Samowitz, Wade S; Swensen, Jeffrey J
2013-01-01
Lynch syndrome is characterized by mutations in one of four mismatch repair genes, MLH1, MSH2, MSH6, or PMS2. Clinical mutation analysis of these genes includes sequencing of exonic regions and deletion/duplication analysis. However, detection of deletions and duplications in PMS2 has previously been confined to Exons 1-11 due to gene conversion between PMS2 and the pseudogene PMS2CL in the remaining 3' exons (Exons 12-15). We have recently described an MLPA-based method that permits detection of deletions of PMS2 Exons 12-15; however, the frequency of such deletions has not yet been determined. To address this question, we tested for 3' deletions in 58 samples that were reported to be negative for PMS2 mutations using previously available methods. All samples were from individuals whose tumors exhibited loss of PMS2 immunohistochemical staining without concomitant loss of MLH1 immunostaining. We identified seven samples in this cohort with deletions in the 3' region of PMS2, including three previously reported samples with deletions of Exons 13-15 (two samples) and Exons 14-15. Also detected were deletions of Exons 12-15, Exon 13, and Exon 14 (two samples). Breakpoint analysis of the intragenic deletions suggests they occurred through Alu-mediated recombination. Our results indicate that ∼12% of samples suspected of harboring a PMS2 mutation based on immunohistochemical staining, for which mutations have not yet been identified, would benefit from testing using the new methodology. Copyright © 2012 Wiley Periodicals, Inc.
qPMS7: a fast algorithm for finding (ℓ, d-motifs in DNA and protein sequences.
Directory of Open Access Journals (Sweden)
Hieu Dinh
Full Text Available Detection of rare events happening in a set of DNA/protein sequences could lead to new biological discoveries. One kind of such rare events is the presence of patterns called motifs in DNA/protein sequences. Finding motifs is a challenging problem since the general version of motif search has been proven to be intractable. Motifs discovery is an important problem in biology. For example, it is useful in the detection of transcription factor binding sites and transcriptional regulatory elements that are very crucial in understanding gene function, human disease, drug design, etc. Many versions of the motif search problem have been proposed in the literature. One such is the (ℓ, d-motif search (or Planted Motif Search (PMS. A generalized version of the PMS problem, namely, Quorum Planted Motif Search (qPMS, is shown to accurately model motifs in real data. However, solving the qPMS problem is an extremely difficult task because a special case of it, the PMS Problem, is already NP-hard, which means that any algorithm solving it can be expected to take exponential time in the worse case scenario. In this paper, we propose a novel algorithm named qPMS7 that tackles the qPMS problem on real data as well as challenging instances. Experimental results show that our Algorithm qPMS7 is on an average 5 times faster than the state-of-art algorithm. The executable program of Algorithm qPMS7 is freely available on the web at http://pms.engr.uconn.edu/downloads/qPMS7.zip. Our online motif discovery tools that use Algorithm qPMS7 are freely available at http://pms.engr.uconn.edu or http://motifsearch.com.
Parameters of the preproduction series SiPMs for the CMS HCAL phase I upgrade
Energy Technology Data Exchange (ETDEWEB)
Heering, A., E-mail: Adriaan.Heering@cern.ch [University of Notre Dame, Notre Dame, IN 46556 (United States); Musienko, Yu., E-mail: Iouri.Musienko@cern.ch [University of Notre Dame, Notre Dame, IN 46556 (United States); Institute for Nuclear Research RAS, pr. 60-letiya Oktyabrya 7a, 117312 Moscow (Russian Federation); Ruchti, R.; Wayne, M. [University of Notre Dame, Notre Dame, IN 46556 (United States); Karneyeu, A.; Postoev, V. [Institute for Nuclear Research RAS, pr. 60-letiya Oktyabrya 7a, 117312 Moscow (Russian Federation)
2016-07-11
In 2012 the HCAL SiPM photo sensor upgrade was approved for the increased luminosity (5*10{sup 34}) of SLHC. The upgrade will replace the current hybrid photodiodes (HPDs) with multi-pixel Geiger-mode avalanche photodiodes, also known as silicon photomultipliers (SiPMs). A key aspect of the upgrade to SiPMs is to add longitudinal segmentation and improve signal to noise to compensate for scintillator radiation damage. After 5 years of R&D with multiple companies we developed custom large dynamic range SiPMs with large PDE and small ENC. To ensure good mechanical alignment and easy handling of the large number of production channels (>20,000) we have developed a custom ceramic package with a very thin 0.3 mm quartz window with Kyocera. Each package holds 8 channels of SiPMs. Here we report on the final SiPM parameters of the 2014 preproduction run from Hamamatsu (HPK) who has produced a series of 175 arrays with a total of 1400 SiPMs. An overview of our QA results and measurements of the photon detection efficiency, spectral response, crosstalk and cell recovery time will be discussed. - Highlights: • Uniformity of large scale SiPM production. • Small cell size SiPMs with high photo detection efficiency. • Fast recovery time SiPMs. • Custom packaging of SiPMs in High Energy Physics experiments.
Functional role of DNA mismatch repair gene PMS2 in prostate cancer cells.
Fukuhara, Shinichiro; Chang, Inik; Mitsui, Yozo; Chiyomaru, Takeshi; Yamamura, Soichiro; Majid, Shahana; Saini, Sharanjot; Deng, Guoren; Gill, Ankurpreet; Wong, Darryn K; Shiina, Hiroaki; Nonomura, Norio; Lau, Yun-Fai C; Dahiya, Rajvir; Tanaka, Yuichiro
2015-06-30
DNA mismatch repair (MMR) enzymes act as proofreading complexes that maintains genomic integrity and MMR-deficient cells show an increased mutation rate. MMR has also been shown to influence cell signaling and the regulation of tumor development. MMR consists of various genes and includes post-meiotic segregation (PMS) 2 which is a vital component of mutL-alpha. In prostate, the functional role of this gene has never been reported and in this study, our aim was to investigate the effect of PMS2 on growth properties of prostate cancer (PCa) cells. Previous studies have shown PMS2 to be deficient in DU145 cells and this lack of expression was confirmed by Western blotting whereas normal prostatic PWR-1E and RWPE-1 cells expressed this gene. PMS2 effects on various growth properties of DU145 were then determined by creating stable gene transfectants. Interestingly, PMS2 caused decreased cell proliferation, migration, invasion, and in vivo growth; and increased apoptosis as compared to vector control. We further analyzed genes affected by PMS2 expression and observe the apoptosis-related TMS1 gene to be significantly upregulated whereas anti-apoptotic BCL2A1 was downregulated. These results demonstrate a functional role for PMS2 to protect against PCa progression by enhancing apoptosis of PCa cells.
A frame-shift mutation of PMS2 is a widespread cause of Lynch syndrome
DEFF Research Database (Denmark)
Clendenning, Mark; Senter, Leigha; Hampel, Heather
2008-01-01
BACKGROUND: When compared to the other mismatch repair genes involved in Lynch syndrome, the identification of mutations within PMS2 has been limited (Lynch syndrome cases...... on immunohistochemical analysis. RESULTS: We have identified a frequently occurring frame-shift mutation (c.736_741del6ins11) in 12 ostensibly unrelated Lynch syndrome patients (20% of patients we have identified with a deleterious mutation in PMS2, n=61). These individuals all display the rare allele (population...... are caused by PMS2. This disparity is primarily due to complications in the study of this gene caused by interference from pseudogene sequences. METHODS: Using a recently developed method for detecting PMS2 specific mutations, we have screened 99 patients who are likely candidates for PMS2 mutations based...
Recurrent and founder mutations in the PMS2 gene.
Tomsic, J; Senter, L; Liyanarachchi, S; Clendenning, M; Vaughn, C P; Jenkins, M A; Hopper, J L; Young, J; Samowitz, W; de la Chapelle, A
2013-03-01
Germline mutations in PMS2 are associated with Lynch syndrome (LS), the most common known cause of hereditary colorectal cancer. Mutation detection in PMS2 has been difficult due to the presence of several pseudogenes, but a custom-designed long-range PCR strategy now allows adequate mutation detection. Many mutations are unique. However, some mutations are observed repeatedly across individuals not known to be related due to the mutation being either recurrent, arising multiple times de novo at hot spots for mutations, or of founder origin, having occurred once in an ancestor. Previously, we observed 36 distinct mutations in a sample of 61 independently ascertained Caucasian probands of mixed European background with PMS2 mutations. Eleven of these mutations were detected in more than one individual not known to be related and of these, six were detected more than twice. These six mutations accounted for 31 (51%) ostensibly unrelated probands. Here, we performed genotyping and haplotype analysis in four mutations observed in multiple probands and found two (c.137G>T and exon 10 deletion) to be founder mutations and one (c.903G>T) a probable founder. One (c.1A>G) could not be evaluated for founder mutation status. We discuss possible explanations for the frequent occurrence of founder mutations in PMS2. © 2012 John Wiley & Sons A/S.
A Comprehensive Strategy for Accurate Mutation Detection of the Highly Homologous PMS2.
Li, Jianli; Dai, Hongzheng; Feng, Yanming; Tang, Jia; Chen, Stella; Tian, Xia; Gorman, Elizabeth; Schmitt, Eric S; Hansen, Terah A A; Wang, Jing; Plon, Sharon E; Zhang, Victor Wei; Wong, Lee-Jun C
2015-09-01
Germline mutations in the DNA mismatch repair gene PMS2 underlie the cancer susceptibility syndrome, Lynch syndrome. However, accurate molecular testing of PMS2 is complicated by a large number of highly homologous sequences. To establish a comprehensive approach for mutation detection of PMS2, we have designed a strategy combining targeted capture next-generation sequencing (NGS), multiplex ligation-dependent probe amplification, and long-range PCR followed by NGS to simultaneously detect point mutations and copy number changes of PMS2. Exonic deletions (E2 to E9, E5 to E9, E8, E10, E14, and E1 to E15), duplications (E11 to E12), and a nonsense mutation, p.S22*, were identified. Traditional multiplex ligation-dependent probe amplification and Sanger sequencing approaches cannot differentiate the origin of the exonic deletions in the 3' region when PMS2 and PMS2CL share identical sequences as a result of gene conversion. Our approach allows unambiguous identification of mutations in the active gene with a straightforward long-range-PCR/NGS method. Breakpoint analysis of multiple samples revealed that recurrent exon 14 deletions are mediated by homologous Alu sequences. Our comprehensive approach provides a reliable tool for accurate molecular analysis of genes containing multiple copies of highly homologous sequences and should improve PMS2 molecular analysis for patients with Lynch syndrome. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Marinovic-Terzic, Ivana; Yoshioka-Yamashita, Atsuko; Shimodaira, Hideki; Avdievich, Elena; Hunton, Irina C; Kolodner, Richard D; Edelmann, Winfried; Wang, Jean Y J
2008-09-16
Mismatch repair (MMR) corrects replication errors during DNA synthesis. The mammalian MMR proteins also activate cell cycle checkpoints and apoptosis in response to persistent DNA damage. MMR-deficient cells are resistant to cisplatin, a DNA cross-linking agent used in chemotherapy, because of impaired activation of apoptotic pathways. It is shown that postmeiotic segregation 2 (PMS2), an MMR protein, is required for cisplatin-induced activation of p73, a member of the p53 family of transcription factors with proapoptotic activity. The human PMS2 is highly polymorphic, with at least 12 known nonsynonymous codon changes identified. We show here that the PMS2(R20Q) variant is defective in activating p73-dependent apoptotic response to cisplatin. When expressed in Pms2-deficient mouse fibroblasts, human PMS2(R20Q) but not PMS2 interfered with the apoptotic response to cisplatin. Correspondingly, PMS2 but not PMS2(R20Q) enhanced the cytotoxic effect of cisplatin measured by clonogenic survival. Because PMS2(R20Q) lacks proapoptotic activity, this polymorphic allele may modulate tumor responses to cisplatin among cancer patients.
Artefactual punctate MLH1 staining can lead to erroneous reporting of isolated PMS2 loss.
Niu, Bonnie T; Hammond, Rory F L; Leen, Sarah L S; Faruqi, Asma Z; Trevisan, Giorgia; Gilks, C Blake; Singh, Naveena
2018-05-31
Germline mutations in the PMS2 gene are an uncommon cause of Lynch Syndrome (LS), present in PMS2 immunohistochemical expression, with retained MLH1 expression, triggers referral to genetics services due to the significant risk of LS 3 . As detection of PMS2 germline mutations is problematic 4 , this may result in patients being labeled as "Lynch-like", with implications for future surveillance 5 . A recent study suggested that some cases of isolated PMS2 loss result from MLH1 promoter methylation and are sporadic rather than likely LS 6 ; they therefore recommended MLH1 promoter methylation testing in all cases of isolated PMS2 loss 6 . This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
High Power Wind Generator Designs with Less or No PMs
DEFF Research Database (Denmark)
Boldea, Ion; Tutelea, Lucian; Blaabjerg, Frede
2014-01-01
synchronous generators, by doubly-fed (wound rotor) induction and cage induction generators and by introducing new topologies with pertinent costs for high power (MW range) wind energy conversion units. The present overview attempts, based on recent grid specifications, an evaluation of commercial and novel...... considering the interaction with the PWM converter in terms of power/speed range, losses, kVA, and costs) rather than on the control issues which abound in literature, will be of use for future R&D efforts in wind energy conversion, storage and use.......The recent steep increase in high energy permanent magnet (PM) price (above 130$/kg and more) triggered already strong R&D efforts to develop wind generators with less PMs (less weight in NdFeB magnets/kW or the use of ferrite PMs) or fully without PMs. All these by optimizing existing dc excited...
Auclair, Jessie; Leroux, Dominique; Desseigne, Françoise; Lasset, Christine; Saurin, Jean Christophe; Joly, Marie Odile; Pinson, Stéphane; Xu, Xiao Li; Montmain, Gilles; Ruano, Eric; Navarro, Claudine; Puisieux, Alain; Wang, Qing
2007-11-01
Since the first report by our group in 1999, more than 20 unrelated biallelic mutations in DNA mismatch repair genes (MMR) have been identified. In the present report, we describe two novel cases: one carrying compound heterozygous mutations in the MSH6 gene; and the other, compound heterozygous mutations in the PMS2 gene. Interestingly, the inactivation of one PMS2 allele was likely caused by gene conversion. Although gene conversion has been suggested to be a mutation mechanism underlying PMS2 inactivation, this is the first report of its involvement in a pathogenic mutation. The clinical features of biallelic mutation carriers were similar to other previously described patients, with the presence of café-au-lait spots (CALS), early onset of brain tumors, and colorectal neoplasia. Our data provide further evidence of the existence, although rare, of a distinct recessively inherited syndrome on the basis of MMR constitutional inactivation. The identification of this syndrome should be useful for genetic counseling, especially in families with atypical hereditary nonpolyposis colon cancer (HNPCC) associated with childhood cancers, and for the clinical surveillance of these mutation carriers. 2007 Wiley-Liss, Inc.
Lynch syndrome caused by germline PMS2 mutations: delineating the cancer risk
Broeke, S.W. ten; Brohet, R.M.; Tops, C.M.; Klift, H.M. van der; Velthuizen, M.E.; Bernstein, I.; Capella Munar, G.; Garcia, E.; Hoogerbrugge, N.; Letteboer, T.G.; Menko, F.H.; Lindblom, A.; Mensenkamp, A.R.; Moller, P.; Os, T.A. van; Rahner, N.; Redeker, B.J.; Sijmons, R.H.; Spruijt, L.; Suerink, M.; Vos, Y.J.; Wagner, A.; Hes, F.J.; Vasen, H.F.A.; Nielsen, M.; Wijnen, J.T.
2015-01-01
PURPOSE: The clinical consequences of PMS2 germline mutations are poorly understood compared with other Lynch-associated mismatch repair gene (MMR) mutations. The aim of this European cohort study was to define the cancer risk faced by PMS2 mutation carriers. METHODS: Data were collected from 98
Effectiveness of group cognitive-behavioral therapy on symptoms of premenstrual syndrome (PMS
Directory of Open Access Journals (Sweden)
Maryam Maddineshat
2016-02-01
Full Text Available Objective: Standards of care and treatment of premenstrual syndrome (PMS vary. Non-drug psychosocial intervention therapy is recommended for women with any kind of discomfort or distress caused by PMS. The current study examined the effectiveness of group cognitive-behavioral therapy on the symptoms of PMS at a girls’ dormitory of North Khorasan University of Medical Sciences.Method: In this quasi-experimental study, 32 female students with PMS who were majoring in nursing and midwifery and residing in the dormitory were selected using the convenience sampling method and were assigned to experimental and control groups. The Standardized Premenstrual Symptoms Screening Tool was used as the research tool. Eight sessions of cognitive-behavioral group therapy were held for the studentsResults: There was a significant difference in psychological symptoms before and after cognitive-behavioral therapy (p=0.012. Furthermore, cognitive-behavioral therapy was effective on social interferences caused by PMS symptoms (p=0.012.Conclusion: Group cognitive-behavioral therapy effectively alleviates PMS symptoms in female college students.
The changing landscape of Lynch syndrome due to PMS2 mutations.
Blount, J; Prakash, A
2018-07-01
DNA repair pathways are essential for cellular survival as our DNA is constantly under assault from both exogenous and endogenous DNA damaging agents. Five major mammalian DNA repair pathways exist within a cell to maintain genomic integrity. Of these, the DNA mismatch repair (MMR) pathway is highly conserved among species and is well documented in bacteria. In humans, the importance of MMR is underscored by the discovery that a single mutation in any 1 of 4 genes within the MMR pathway (MLH1, MSH2, MSH6 and PMS2) results in Lynch syndrome (LS). LS is a autosomal dominant condition that predisposes individuals to a higher incidence of many malignancies including colorectal, endometrial, ovarian, and gastric cancers. In this review, we discuss the role of PMS2 in the MMR pathway, the evolving testing criteria used to identify variants in the PMS2 gene, the LS phenotype as well as the autosomal recessive condition called constitutional mismatch repair deficiency syndrome, and current methods used to elucidate the clinical impact of PMS2 mutations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lynch syndrome caused by germline PMS2 mutations: delineating the cancer risk.
ten Broeke, Sanne W; Brohet, Richard M; Tops, Carli M; van der Klift, Heleen M; Velthuizen, Mary E; Bernstein, Inge; Capellá Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G W; Menko, Fred H; Lindblom, Annika; Mensenkamp, Arjen R; Moller, Pal; van Os, Theo A; Rahner, Nils; Redeker, Bert J W; Sijmons, Rolf H; Spruijt, Liesbeth; Suerink, Manon; Vos, Yvonne J; Wagner, Anja; Hes, Frederik J; Vasen, Hans F; Nielsen, Maartje; Wijnen, Juul T
2015-02-01
The clinical consequences of PMS2 germline mutations are poorly understood compared with other Lynch-associated mismatch repair gene (MMR) mutations. The aim of this European cohort study was to define the cancer risk faced by PMS2 mutation carriers. Data were collected from 98 PMS2 families ascertained from family cancer clinics that included a total of 2,548 family members and 377 proven mutation carriers. To adjust for potential ascertainment bias, a modified segregation analysis model was used to calculate colorectal cancer (CRC) and endometrial cancer (EC) risks. Standardized incidence ratios (SIRs) were calculated to estimate risks for other Lynch syndrome-associated cancers. The cumulative risk (CR) of CRC for male mutation carriers by age 70 years was 19%. The CR among female carriers was 11% for CRC and 12% for EC. The mean age of CRC development was 52 years, and there was a significant difference in mean age of CRC between the probands (mean, 47 years; range, 26 to 68 years) and other family members with a PMS2 mutation (mean, 58 years; range, 31 to 86 years; P PMS2 mutation, and it should be noted that we observed a substantial variation in cancer phenotype within and between families, suggesting the influence of genetic modifiers and lifestyle factors on cancer risks. © 2014 by American Society of Clinical Oncology.
Borràs, Ester; Pineda, Marta; Cadiñanos, Juan; Del Valle, Jesús; Brieger, Angela; Hinrichsen, Inga; Cabanillas, Ruben; Navarro, Matilde; Brunet, Joan; Sanjuan, Xavier; Musulen, Eva; van der Klift, Helen; Lázaro, Conxi; Plotz, Guido; Blanco, Ignacio; Capellá, Gabriel
2013-08-01
The majority of mismatch repair (MMR) gene mutations causing Lynch syndrome (LS) occur either in MLH1 or MSH2. However, the relative contribution of PMS2 is less well defined. The aim of this study was to evaluate the role of PMS2 in LS by assessing the pathogenicity of variants of unknown significance (VUS) detected in the mutational analysis of PMS2 in a series of Spanish patients. From a cohort of 202 LS suspected patients, 13 patients showing loss of PMS2 expression in tumours were screened for germline mutations in PMS2, using a long range PCR based strategy and multiplex ligation dependent probe amplification (MLPA). Pathogenicity assessment of PMS2 VUS was performed evaluating clinicopathological data, frequency in control population and in silico and in vitro analyses at the RNA and protein level. Overall 25 different PMS2 DNA variants were detected. Fourteen were classified as polymorphisms. Nine variants were classified as pathogenic: seven alterations based on their molecular nature and two after demonstrating a functional defect (c.538-3C>G affected mRNA processing and c.137G>T impaired MMR activity). The c.1569C>G variant was classified as likely neutral while the c.384G>A remained as a VUS. We have also shown that the polymorphic variant c.59G>A is MMR proficient. Pathogenic PMS2 mutations were detected in 69% of patients harbouring LS associated tumours with loss of PMS2 expression. In all, PMS2 mutations account for 6% of the LS cases identified. The comprehensive functional analysis shown here has been useful in the classification of PMS2 VUS and contributes to refining the role of PMS2 in LS.
A frame-shift mutation of PMS2 is a widespread cause of Lynch syndrome.
Clendenning, M; Senter, L; Hampel, H; Robinson, K Lagerstedt; Sun, S; Buchanan, D; Walsh, M D; Nilbert, M; Green, J; Potter, J; Lindblom, A; de la Chapelle, A
2008-06-01
When compared to the other mismatch repair genes involved in Lynch syndrome, the identification of mutations within PMS2 has been limited (PMS2. This disparity is primarily due to complications in the study of this gene caused by interference from pseudogene sequences. Using a recently developed method for detecting PMS2 specific mutations, we have screened 99 patients who are likely candidates for PMS2 mutations based on immunohistochemical analysis. We have identified a frequently occurring frame-shift mutation (c.736_741del6ins11) in 12 ostensibly unrelated Lynch syndrome patients (20% of patients we have identified with a deleterious mutation in PMS2, n = 61). These individuals all display the rare allele (population frequency 10 000 carriers of this mutation in the USA alone. The identification of both the mutation and the common haplotype in one Swedish control sample (n = 225), along with evidence that Lynch syndrome associated cancers are rarer than expected in the probands' families, would suggest that this is a prevalent mutation with reduced penetrance.
Development of adaptive core emulator for PMS-XRBP of CE type plant
International Nuclear Information System (INIS)
Song, Jae Seung; Zee, Sung Quun; Lee, Chung Chan; Lee, Ki Bog; Rhy, Hyo Sang; Chang, Jong Hwa; Lee, Young Ouk; Baek, Seung Min; Seo, Ho Joon.
1996-12-01
The purpose of this report is to develop ONED-based adaptive core emulator (ACE) for Korean Standard Nuclear Power Plant. This report is first year report and includes 1) augmentation of ONED94 I/O system 2) non-equilibrium xenon initialization for core transient simulation 3) ONED94 verification via plant measurements 4) automatic data link system from PMS and personal computer. (author). 4 tabs., 4 figs., 8 refs
Development of adaptive core emulator for PMS-XRBP of CE type plant
Energy Technology Data Exchange (ETDEWEB)
Song, Jae Seung; Zee, Sung Quun; Lee, Chung Chan; Lee, Ki Bog; Rhy, Hyo Sang; Chang, Jong Hwa; Lee, Young Ouk; Baek, Seung Min; Seo, Ho Joon
1996-12-01
The purpose of this report is to develop ONED-based adaptive core emulator (ACE) for Korean Standard Nuclear Power Plant. This report is first year report and includes (1) augmentation of ONED94 I/O system (2) non-equilibrium xenon initialization for core transient simulation (3) ONED94 verification via plant measurements (4) automatic data link system from PMS and personal computer. (author). 4 tabs., 4 figs., 8 refs.
PMS2 gene mutational analysis: direct cDNA sequencing to circumvent pseudogene interference.
Wimmer, Katharina; Wernstedt, Annekatrin
2014-01-01
The presence of highly homologous pseudocopies can compromise the mutation analysis of a gene of interest. In particular, when using PCR-based strategies, pseudogene co-amplification has to be effectively prevented. This is often achieved by using primers designed to be parental gene specific according to the reference sequence and by applying stringent PCR conditions. However, there are cases in which this approach is of limited utility. For example, it has been shown that the PMS2 gene exchanges sequences with one of its pseudogenes, named PMS2CL. This results in functional PMS2 alleles containing pseudogene-derived sequences at their 3'-end and in nonfunctional PMS2CL pseudogene alleles that contain gene-derived sequences. Hence, the paralogues cannot be distinguished according to the reference sequence. This shortcoming can be effectively circumvented by using direct cDNA sequencing. This approach is based on the selective amplification of PMS2 transcripts in two overlapping 1.6-kb RT-PCR products. In addition to avoiding pseudogene co-amplification and allele dropout, this method has also the advantage that it allows to effectively identify deletions, splice mutations, and de novo retrotransposon insertions that escape the detection of most DNA-based mutation analysis protocols.
Development of high performance readout ASICs for silicon photomultipliers (SiPMs)
International Nuclear Information System (INIS)
Shen, Wei
2012-01-01
Silicon Photomultipliers (SiPMs) are novel kind of solid state photon detectors with extremely high photon detection resolution. They are composed of hundreds or thousands of avalanche photon diode pixels connected in parallel. These avalanche photon diodes are operated in Geiger Mode. SiPMs have the same magnitude of multiplication gain compared to the conventional photomultipliers (PMTs). Moreover, they have a lot of advantages such as compactness, relatively low bias voltage and magnetic field immunity etc. Special readout electronics are required to preserve the high performance of the detector. KLauS and STiC are two CMOS ASIC chips designed in particular for SiPMs. KLauS is used for SiPM charge readout applications. Since SiPMs have a much larger detector capacitance compared to other solid state photon detectors such as PIN diodes and APDs, a few special techniques are used inside the chip to make sure a descent signal to noise ratio for pixel charge signal can be obtained. STiC is a chip dedicated to SiPM time-of-flight applications. High bandwidth and low jitter design schemes are mandatory for such applications where time jitter less than tens of picoseconds is required. Design schemes and error analysis as well as measurement results are presented in the thesis.
The PM/S module and the BIO/TSR requirements comparison report summary
International Nuclear Information System (INIS)
PEERY, B.Q.
1999-01-01
This report summarizes the comparison between the Preventive Maintenance/Surveillance System (PM/S) database and the requirements identified in the Tank Waste Remediation Systems Basis for Interim Operation (BIO) (HNF-SD-WM-BIO-001); the Technical Safety Requirements (TSR's) (HNF-SD-WM-TSR-006); The Tank Farms Administrative Controls Manual, (HNF-IP-1266); and The TWRS Facility Safety Equipment List, (HNF-SD-WM-SEL-0404). Corrective actions identified are completed or in process
Zhang, Yuan; Shu, Yi Min; Wang, Shu Fang; Da, Bang Hong; Wang, Ze Hua; Li, Hua Bin
2010-02-23
PMS2 expression loss was reported in a variety of human. However, its importance has not been fully understood in cervical carcinoma. The aim of this study was to determine the expression of PMS2 in cervical carcinoma and evaluate the significance of mismatch repair gene PMS2 regulated by glycogen synthase kinase 3beta (GSK-3beta) in chemosensitivity. We examined PMS2 and phosphorylated GSK-3beta(s9) expression in cervical carcinoma tissues using immunohistochemical staining. Furthermore, we detected PMS2 expression in HeLa cells and evaluate the interaction with GSK-3beta after transfection with GSK-3beta by small interference RNA (siRNA), co-immunoprecipitation and immunoblotting. We also evaluated the effect of PMS2 transfection on HeLa cells' chemosensitivity to cisplatin treatment. We found significant downregulation of PMS2 in cervical carcinoma, which was negatively associated with phosphorylated GSK-3beta (s9). Furthermore, we demonstrated GSK-3beta transfection was able to interact with PMS2 and enhance PMS2 production in HeLa cells, and increased PMS2 production was responsible for enhanced chemosensitivity. Our results provide the evidence that stabilization of PMS2 production by GSK-3beta was important to improve chemosensitization, indicating the significance of GSK-3beta-related PMS2 downregulation in the development of cervical carcinoma and in developing a potential strategy for chemotherapy.
Energy Technology Data Exchange (ETDEWEB)
Zhang, Yuan [Department of Obstetrics and Gynecology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022 (China); Shu, Yi Min [Allergy and Cancer Center, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080 (China); Wang, Shu Fang [Department of Pathology, Baylor College of Medicine, Houston, TX 77030 (United States); Da, Bang Hong; Wang, Ze Hua [Department of Obstetrics and Gynecology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022 (China); Li, Hua Bin [Allergy and Cancer Center, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080 (China); Department of Medicine, Feinberg Medical School, Northwestern University, Chicago, IL 60611 (United States)
2010-02-23
PMS2 expression loss was reported in a variety of human. However, its importance has not been fully understood in cervical carcinoma. The aim of this study was to determine the expression of PMS2 in cervical carcinoma and evaluate the significance of mismatch repair gene PMS2 regulated by glycogen synthase kinase 3β (GSK-3β) in chemosensitivity. We examined PMS2 and phosphorylated GSK-3β(s9) expression in cervical carcinoma tissues using immunohistochemical staining. Furthermore, we detected PMS2 expression in HeLa cells and evaluate the interaction with GSK-3β after transfection with GSK-3β by small interference RNA (siRNA), co-immunoprecipitation and immunoblotting. We also evaluated the effect of PMS2 transfection on HeLa cells' chemosensitivity to cisplatin treatment. We found significant downregulation of PMS2 in cervical carcinoma, which was negatively associated with phosphorylated GSK-3β (s9). Furthermore, we demonstrated GSK-3β transfection was able to interact with PMS2 and enhance PMS2 production in HeLa cells, and increased PMS2 production was responsible for enhanced chemosensitivity. Our results provide the evidence that stabilization of PMS2 production by GSK-3β was important to improve chemosensitization, indicating the significance of GSK-3β-related PMS2 downregulation in the development of cervical carcinoma and in developing a potential strategy for chemotherapy.
International Nuclear Information System (INIS)
Zhang, Yuan; Shu, Yi Min; Wang, Shu Fang; Da, Bang Hong; Wang, Ze Hua; Li, Hua Bin
2010-01-01
PMS2 expression loss was reported in a variety of human. However, its importance has not been fully understood in cervical carcinoma. The aim of this study was to determine the expression of PMS2 in cervical carcinoma and evaluate the significance of mismatch repair gene PMS2 regulated by glycogen synthase kinase 3β (GSK-3β) in chemosensitivity. We examined PMS2 and phosphorylated GSK-3β(s9) expression in cervical carcinoma tissues using immunohistochemical staining. Furthermore, we detected PMS2 expression in HeLa cells and evaluate the interaction with GSK-3β after transfection with GSK-3β by small interference RNA (siRNA), co-immunoprecipitation and immunoblotting. We also evaluated the effect of PMS2 transfection on HeLa cells' chemosensitivity to cisplatin treatment. We found significant downregulation of PMS2 in cervical carcinoma, which was negatively associated with phosphorylated GSK-3β (s9). Furthermore, we demonstrated GSK-3β transfection was able to interact with PMS2 and enhance PMS2 production in HeLa cells, and increased PMS2 production was responsible for enhanced chemosensitivity. Our results provide the evidence that stabilization of PMS2 production by GSK-3β was important to improve chemosensitization, indicating the significance of GSK-3β-related PMS2 downregulation in the development of cervical carcinoma and in developing a potential strategy for chemotherapy
Pms2 suppresses large expansions of the (GAA·TTCn sequence in neuronal tissues.
Directory of Open Access Journals (Sweden)
Rebecka L Bourn
Full Text Available Expanded trinucleotide repeat sequences are the cause of several inherited neurodegenerative diseases. Disease pathogenesis is correlated with several features of somatic instability of these sequences, including further large expansions in postmitotic tissues. The presence of somatic expansions in postmitotic tissues is consistent with DNA repair being a major determinant of somatic instability. Indeed, proteins in the mismatch repair (MMR pathway are required for instability of the expanded (CAG·CTG(n sequence, likely via recognition of intrastrand hairpins by MutSβ. It is not clear if or how MMR would affect instability of disease-causing expanded trinucleotide repeat sequences that adopt secondary structures other than hairpins, such as the triplex/R-loop forming (GAA·TTC(n sequence that causes Friedreich ataxia. We analyzed somatic instability in transgenic mice that carry an expanded (GAA·TTC(n sequence in the context of the human FXN locus and lack the individual MMR proteins Msh2, Msh6 or Pms2. The absence of Msh2 or Msh6 resulted in a dramatic reduction in somatic mutations, indicating that mammalian MMR promotes instability of the (GAA·TTC(n sequence via MutSα. The absence of Pms2 resulted in increased accumulation of large expansions in the nervous system (cerebellum, cerebrum, and dorsal root ganglia but not in non-neuronal tissues (heart and kidney, without affecting the prevalence of contractions. Pms2 suppressed large expansions specifically in tissues showing MutSα-dependent somatic instability, suggesting that they may act on the same lesion or structure associated with the expanded (GAA·TTC(n sequence. We conclude that Pms2 specifically suppresses large expansions of a pathogenic trinucleotide repeat sequence in neuronal tissues, possibly acting independently of the canonical MMR pathway.
Radiation monitoring network in Poland
International Nuclear Information System (INIS)
Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Smagala, G.; Swietochowska, J.
2001-01-01
In Poland the radioactive contamination of the environment and food has been controlled since the early sixties by the Service for Measurements of Radioactive Contamination (SPSP). The service comprises a network of measuring stations and the Centre of Radioactive Contamination Measurements (COPSP). Actually, there are 100 measurement stations. The main task of such station is systematic measurement of radioactivity level in samples of environment components and food. Nine stations of SPSP acting within meteorological stations, ten stations of low level air radioactivity measurements (Aerosols Sampling Stations-500) and eleven permanent monitoring stations (PMS) form the radiation monitoring warning system in Poland. (author)
van der Klift, Heleen M; Mensenkamp, Arjen R; Drost, Mark; Bik, Elsa C; Vos, Yvonne J; Gille, Hans J J P; Redeker, Bert E J W; Tiersma, Yvonne; Zonneveld, José B M; García, Encarna Gómez; Letteboer, Tom G W; Olderode-Berends, Maran J W; van Hest, Liselotte P; van Os, Theo A; Verhoef, Senno; Wagner, Anja; van Asperen, Christi J; Ten Broeke, Sanne W; Hes, Frederik J; de Wind, Niels; Nielsen, Maartje; Devilee, Peter; Ligtenberg, Marjolijn J L; Wijnen, Juul T; Tops, Carli M J
2016-11-01
Monoallelic PMS2 germline mutations cause 5%-15% of Lynch syndrome, a midlife cancer predisposition, whereas biallelic PMS2 mutations cause approximately 60% of constitutional mismatch repair deficiency (CMMRD), a rare childhood cancer syndrome. Recently improved DNA- and RNA-based strategies are applied to overcome problematic PMS2 mutation analysis due to the presence of pseudogenes and frequent gene conversion events. Here, we determined PMS2 mutation detection yield and mutation spectrum in a nationwide cohort of 396 probands. Furthermore, we studied concordance between tumor IHC/MSI (immunohistochemistry/microsatellite instability) profile and mutation carrier state. Overall, we found 52 different pathogenic PMS2 variants explaining 121 Lynch syndrome and nine CMMRD patients. In vitro mismatch repair assays suggested pathogenicity for three missense variants. Ninety-one PMS2 mutation carriers (70%) showed isolated loss of PMS2 in their tumors, for 31 (24%) no or inconclusive IHC was available, and eight carriers (6%) showed discordant IHC (presence of PMS2 or loss of both MLH1 and PMS2). Ten cases with isolated PMS2 loss (10%; 10/97) harbored MLH1 mutations. We confirmed that recently improved mutation analysis provides a high yield of PMS2 mutations in patients with isolated loss of PMS2 expression. Application of universal tumor prescreening methods will however miss some PMS2 germline mutation carriers. © 2016 WILEY PERIODICALS, INC.
Sugano, Kokichi; Nakajima, Takeshi; Sekine, Shigeki; Taniguchi, Hirokazu; Saito, Shinya; Takahashi, Masahiro; Ushiama, Mineko; Sakamoto, Hiromi; Yoshida, Teruhiko
2016-11-01
Germline PMS2 gene mutations were detected by RT-PCR/direct sequencing of total RNA extracted from puromycin-treated peripheral blood lymphocytes (PBL) and multiplex ligation-dependent probe amplification (MLPA) analyses of Japanese patients with colorectal cancer (CRC) fulfilling either the revised Bethesda Guidelines or being an age at disease onset of younger than 70 years, and screened by mismatch repair protein immunohistochemistry of formalin-fixed paraffin embedded sections. Of the 501 subjects examined, 7 (1.40%) showed the downregulated expression of the PMS2 protein alone and were referred to the genetic counseling clinic. Germline PMS2 mutations were detected in 6 (85.7%), including 3 nonsense and 1 frameshift mutations by RT-PCR/direct sequencing and 2 genomic deletions by MLPA. No mutations were identified in the other MMR genes (i.e. MSH2, MLH1 and MSH6). The prevalence of the downregulated expression of the PMS2 protein alone was 1.40% among the subjects examined and IHC results predicted the presence of PMS2 germline mutations. RT-PCR from puromycin-treated PBL and MLPA may be employed as the first screening step to detect PMS2 mutations without pseudogene interference, followed by the long-range PCR/nested PCR validation using genomic DNA. © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.
Directory of Open Access Journals (Sweden)
Wang Ze
2010-02-01
Full Text Available Abstract Background PMS2 expression loss was reported in a variety of human. However, its importance has not been fully understood in cervical carcinoma. The aim of this study was to determine the expression of PMS2 in cervical carcinoma and evaluate the significance of mismatch repair gene PMS2 regulated by glycogen synthase kinase 3β (GSK-3β in chemosensitivity. Methods We examined PMS2 and phosphorylated GSK-3β(s9 expression in cervical carcinoma tissues using immunohistochemical staining. Furthermore, we detected PMS2 expression in HeLa cells and evaluate the interaction with GSK-3β after transfection with GSK-3β by small interference RNA (siRNA, co-immunoprecipitation and immunoblotting. We also evaluated the effect of PMS2 transfection on HeLa cells' chemosensitivity to cisplatin treatment. Results We found significant downregulation of PMS2 in cervical carcinoma, which was negatively associated with phosphorylated GSK-3β (s9. Furthermore, we demonstrated GSK-3β transfection was able to interact with PMS2 and enhance PMS2 production in HeLa cells, and increased PMS2 production was responsible for enhanced chemosensitivity. Conclusions Our results provide the evidence that stabilization of PMS2 production by GSK-3β was important to improve chemosensitization, indicating the significance of GSK-3β-related PMS2 downregulation in the development of cervical carcinoma and in developing a potential strategy for chemotherapy.
2010-01-01
Background PMS2 expression loss was reported in a variety of human. However, its importance has not been fully understood in cervical carcinoma. The aim of this study was to determine the expression of PMS2 in cervical carcinoma and evaluate the significance of mismatch repair gene PMS2 regulated by glycogen synthase kinase 3β (GSK-3β) in chemosensitivity. Methods We examined PMS2 and phosphorylated GSK-3β(s9) expression in cervical carcinoma tissues using immunohistochemical staining. Furthermore, we detected PMS2 expression in HeLa cells and evaluate the interaction with GSK-3β after transfection with GSK-3β by small interference RNA (siRNA), co-immunoprecipitation and immunoblotting. We also evaluated the effect of PMS2 transfection on HeLa cells' chemosensitivity to cisplatin treatment. Results We found significant downregulation of PMS2 in cervical carcinoma, which was negatively associated with phosphorylated GSK-3β (s9). Furthermore, we demonstrated GSK-3β transfection was able to interact with PMS2 and enhance PMS2 production in HeLa cells, and increased PMS2 production was responsible for enhanced chemosensitivity. Conclusions Our results provide the evidence that stabilization of PMS2 production by GSK-3β was important to improve chemosensitization, indicating the significance of GSK-3β-related PMS2 downregulation in the development of cervical carcinoma and in developing a potential strategy for chemotherapy. PMID:20178594
Efficient Detection of Copy Number Mutations in PMS2 Exons with a Close Homolog.
Herman, Daniel S; Smith, Christina; Liu, Chang; Vaughn, Cecily P; Palaniappan, Selvi; Pritchard, Colin C; Shirts, Brian H
2018-07-01
Detection of 3' PMS2 copy-number mutations that cause Lynch syndrome is difficult because of highly homologous pseudogenes. To improve the accuracy and efficiency of clinical screening for these mutations, we developed a new method to analyze standard capture-based, next-generation sequencing data to identify deletions and duplications in PMS2 exons 9 to 15. The approach captures sequences using PMS2 targets, maps sequences randomly among regions with equal mapping quality, counts reads aligned to homologous exons and introns, and flags read count ratios outside of empirically derived reference ranges. The method was trained on 1352 samples, including 8 known positives, and tested on 719 samples, including 17 known positives. Clinical implementation of the first version of this method detected new mutations in the training (N = 7) and test (N = 2) sets that had not been identified by our initial clinical testing pipeline. The described final method showed complete sensitivity in both sample sets and false-positive rates of 5% (training) and 7% (test), dramatically decreasing the number of cases needing additional mutation evaluation. This approach leveraged the differences between gene and pseudogene to distinguish between PMS2 and PMS2CL copy-number mutations. These methods enable efficient and sensitive Lynch syndrome screening for 3' PMS2 copy-number mutations and may be applied similarly to other genomic regions with highly homologous pseudogenes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Levels of H-ras codon 61 CAA to AAA mutation: response to 4-ABP-treatment and Pms2-deficiency.
Parsons, Barbara L; Delongchamp, Robert R; Beland, Frederick A; Heflich, Robert H
2006-01-01
DNA mismatch repair (MMR) deficiencies result in increased frequencies of spontaneous mutation and tumor formation. In the present study, we tested the hypothesis that a chemically-induced mutational response would be greater in a mouse with an MMR-deficiency than in the MMR-proficient mouse models commonly used to assay for chemical carcinogenicity. To accomplish this, the induction of H-ras codon 61 CAA-->AAA mutation was examined in Pms2 knockout mice (Pms2-/-, C57BL/6 background) and sibling wild-type mice (Pms2+/+). Groups of five or six neonatal male mice were treated with 0.3 micromol 4-aminobiphenyl (4-ABP) or the vehicle control, dimethylsulfoxide. Eight months after treatment, liver DNAs were isolated and analysed for levels of H-ras codon 61 CAA-->AAA mutation using allele-specific competitive blocker-PCR. In Pms2-proficient and Pms2-deficient mice, 4-ABP treatment caused an increase in mutant fraction (MF) from 1.65x10(-5) to 2.91x10(-5) and from 3.40x10(-5) to 4.70x10(-5), respectively. Pooling data from 4-ABP-treated and control mice, the approximately 2-fold increase in MF observed in Pms2-deficient as compared with Pms2-proficient mice was statistically significant (P=0.0207) and consistent with what has been reported previously in terms of induction of G:C-->T:A mutation in a Pms2-deficient background. Pooling data from both genotypes, the increase in H-ras MF in 4-ABP-treated mice, as compared with control mice, did not reach the 95% confidence level of statistical significance (P=0.0606). The 4-ABP treatment caused a 1.76-fold and 1.38-fold increase in average H-ras MF in Pms2-proficient and Pms2-deficient mice, respectively. Furthermore, the levels of induced mutation in Pms2-proficient and Pms2-deficient mice were nearly identical (1.26x10(-5) and 1.30x10(-5), respectively). We conclude that Pms2-deficiency does not result in an amplification of the H-ras codon 61 CAA-->AAA mutational response induced by 4-ABP.
High incidence of large deletions in the PMS2 gene in Spanish Lynch syndrome families.
Brea-Fernández, A J; Cameselle-Teijeiro, J M; Alenda, C; Fernández-Rozadilla, C; Cubiella, J; Clofent, J; Reñé, J M; Anido, U; Milá, M; Balaguer, F; Castells, A; Castellvi-Bel, S; Jover, R; Carracedo, A; Ruiz-Ponte, C
2014-06-01
Lynch syndrome (LS) is caused by germline mutations in one of the four mismatch repair (MMR) genes. Defects in this pathway lead to microsatellite instability (MSI) in DNA tumors, which constitutes the molecular hallmark of this disease. Selection of patients for genetic testing in LS is usually based on fulfillment of diagnostic clinical criteria (i.e. Amsterdam criteria or the revised Bethesda guidelines). However, following these criteria PMS2 mutations have probably been underestimated as their penetrances appear to be lower than those of the other MMR genes. The use of universal MMR study-based strategies, using MSI testing and immunohistochemical (IHC) staining, is being one proposed alternative. Besides, germline mutation detection in PMS2 is complicated by the presence of highly homologous pseudogenes. Nevertheless, specific amplification of PMS2 by long-range polymerase chain reaction (PCR) and the improvement of the analysis of large deletions/duplications by multiplex ligation-dependent probe amplification (MLPA) overcome this difficulty. By using both approaches, we analyzed 19 PMS2-suspected carriers who have been selected by clinical or universal strategies and found five large deletions and one frameshift mutation in PMS2 in six patients (31%). Owing to the high incidence of large deletions found in our cohort, we recommend MLPA analysis as the first-line method for searching germline mutations in PMS2. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Etzler, J; Peyrl, A; Zatkova, A; Schildhaus, H-U; Ficek, A; Merkelbach-Bruse, S; Kratz, C P; Attarbaschi, A; Hainfellner, J A; Yao, S; Messiaen, L; Slavc, I; Wimmer, K
2008-02-01
Heterozygous germline mutations in one of the mismatch repair (MMR) genes MLH1, MSH2, MSH6, and PMS2 cause hereditary nonpolyposis colorectal cancer (HNPCC) or Lynch syndrome, a dominantly inherited cancer susceptibility syndrome. Recent reports provide evidence for a novel recessively inherited cancer syndrome with constitutive MMR deficiency due to biallelic germline mutations in one of the MMR genes. MMR-deficiency (MMR-D) syndrome is characterized by childhood brain tumors, hematological and/or gastrointestinal malignancies, and signs of neurofibromatosis type 1 (NF1). We established an RNA-based mutation detection assay for the four MMR genes, since 1) a number of splicing defects may escape detection by the analysis of genomic DNA, and 2) DNA-based mutation detection in the PMS2 gene is severely hampered by the presence of multiple highly similar pseudogenes, including PMS2CL. Using this assay, which is based on direct cDNA sequencing of RT-PCR products, we investigated two families with children suspected to suffer from MMR-D syndrome. We identified a homozygous complex MSH6 splicing alteration in the index patients of the first family and a novel homozygous PMS2 mutation (c.182delA) in the index patient of the second family. Furthermore, we demonstrate, by the analysis of a PMS2/PMS2CL "hybrid" allele carrier, that RNA-based PMS2 testing effectively avoids the caveats of genomic DNA amplification approaches; i.e., pseudogene coamplification as well as allelic dropout, and will, thus, allow more sensitive mutation analysis in MMR deficiency and in HNPCC patients with PMS2 defects. (c) 2007 Wiley-Liss, Inc.
Elevated levels of the mismatch repair protein PMS2 are associated with prostate cancer.
Norris, Alixanna M; Woodruff, R D; D'Agostino, Ralph B; Clodfelter, Jill E; Scarpinato, Karin Drotschmann
2007-02-01
Defects in mismatch repair (MMR) proteins have been identified in various types of cancer. However, an association with prostate cancer has been controversial. Defective MMR results in genome instability with detrimental consequences that significantly contribute to tumorigenesis. This study determined alterations in key MMR protein levels in prostate cancer with the goal to identify prognostic markers. Prostatectomy samples were immunohistochemically stained and the relative presence or absence of key proteins MSH2, MLH1, and PMS2 determined. Cancer tissue of distinct grades was compared with the normal surrounding tissue. Microsatellite instability (MSI) in altered tissues was determined according to NCI guidelines. In contrast to reports that associate a lack of individual MMR proteins with tumorigenesis, a significant increase in PMS2 levels was identified in PIN lesions and prostate cancer tissue. This elevation in PMS2 was independent of changes in levels in its heterodimeric partner, MLH1. Prostate tumors with elevated levels of PMS2 were genetically unstable, which was corrected by MLH1 co-elevation. This is the first documentation of detrimental consequences associated with the increase in a MMR protein in human cancer. This study recognizes PMS2 elevation as a prognostic marker in pre-neoplastic and prostate cancer lesions. This result has significant implications for future diagnostic and treatment measures. (c) 2006 Wiley-Liss, Inc.
Li, Eldon Y; Tung, Chen-Yuan; Chang, Shu-Hsun
2016-08-01
The quest for an effective system capable of monitoring and predicting the trends of epidemic diseases is a critical issue for communities worldwide. With the prevalence of Internet access, more and more researchers today are using data from both search engines and social media to improve the prediction accuracy. In particular, a prediction market system (PMS) exploits the wisdom of crowds on the Internet to effectively accomplish relatively high accuracy. This study presents the architecture of a PMS and demonstrates the matching mechanism of logarithmic market scoring rules. The system was implemented to predict infectious diseases in Taiwan with the wisdom of crowds in order to improve the accuracy of epidemic forecasting. The PMS architecture contains three design components: database clusters, market engine, and Web applications. The system accumulated knowledge from 126 health professionals for 31 weeks to predict five disease indicators: the confirmed cases of dengue fever, the confirmed cases of severe and complicated influenza, the rate of enterovirus infections, the rate of influenza-like illnesses, and the confirmed cases of severe and complicated enterovirus infection. Based on the winning ratio, the PMS predicts the trends of three out of five disease indicators more accurately than does the existing system that uses the five-year average values of historical data for the same weeks. In addition, the PMS with the matching mechanism of logarithmic market scoring rules is easy to understand for health professionals and applicable to predict all the five disease indicators. The PMS architecture of this study affords organizations and individuals to implement it for various purposes in our society. The system can continuously update the data and improve prediction accuracy in monitoring and forecasting the trends of epidemic diseases. Future researchers could replicate and apply the PMS demonstrated in this study to more infectious diseases and wider
Pms2 suppresses large expansions of the (GAA·TTC)n sequence in neuronal tissues.
Bourn, Rebecka L; De Biase, Irene; Pinto, Ricardo Mouro; Sandi, Chiranjeevi; Al-Mahdawi, Sahar; Pook, Mark A; Bidichandani, Sanjay I
2012-01-01
Expanded trinucleotide repeat sequences are the cause of several inherited neurodegenerative diseases. Disease pathogenesis is correlated with several features of somatic instability of these sequences, including further large expansions in postmitotic tissues. The presence of somatic expansions in postmitotic tissues is consistent with DNA repair being a major determinant of somatic instability. Indeed, proteins in the mismatch repair (MMR) pathway are required for instability of the expanded (CAG·CTG)(n) sequence, likely via recognition of intrastrand hairpins by MutSβ. It is not clear if or how MMR would affect instability of disease-causing expanded trinucleotide repeat sequences that adopt secondary structures other than hairpins, such as the triplex/R-loop forming (GAA·TTC)(n) sequence that causes Friedreich ataxia. We analyzed somatic instability in transgenic mice that carry an expanded (GAA·TTC)(n) sequence in the context of the human FXN locus and lack the individual MMR proteins Msh2, Msh6 or Pms2. The absence of Msh2 or Msh6 resulted in a dramatic reduction in somatic mutations, indicating that mammalian MMR promotes instability of the (GAA·TTC)(n) sequence via MutSα. The absence of Pms2 resulted in increased accumulation of large expansions in the nervous system (cerebellum, cerebrum, and dorsal root ganglia) but not in non-neuronal tissues (heart and kidney), without affecting the prevalence of contractions. Pms2 suppressed large expansions specifically in tissues showing MutSα-dependent somatic instability, suggesting that they may act on the same lesion or structure associated with the expanded (GAA·TTC)(n) sequence. We conclude that Pms2 specifically suppresses large expansions of a pathogenic trinucleotide repeat sequence in neuronal tissues, possibly acting independently of the canonical MMR pathway.
Jia, Jinghui; Wang, Zehua; Cai, Jing; Zhang, Yuan
2016-03-01
Epithelial ovarian cancer (EOC) is the most lethal of the gynecologic malignancies, mainly due to the advanced stage at diagnosis and development of cisplatin resistance. The sensitivity of tumor cells to cisplatin is frequently affected by defect in DNA mismatch repair (MMR), which repairs mispaired DNA sequences and regulates DNA-damage-induced apoptosis. However, the role of postmeiotic segregation increased 2 (PMS2), a member of MMR protein family, in cisplatin resistance remains elusive. In the present study, we demonstrated the frequent deficiency of PMS2 and phosphorylation of Akt in EOC cell lines and tissues. Results of complex immunoprecipitation (co-IP) and protein stability assay indicated that activated Akt could directly bind to PMS2 and cause degradation of PMS2 in EOC cells. In addition, functional experiments revealed that PMS2 was required for cisplatin-induced apoptosis and cell cycle arrest in G2/M phase. These findings provide a novel insight into molecular mechanisms linking MMR with chemoresistance and suggest that stabilization of PMS2 expression may be useful in overcoming the cisplatin resistance in EOC.
SNP association study in PMS2-associated Lynch syndrome.
Ten Broeke, Sanne W; Elsayed, Fadwa A; Pagan, Lisa; Olderode-Berends, Maran J W; Garcia, Encarna Gomez; Gille, Hans J P; van Hest, Liselot P; Letteboer, Tom G W; van der Kolk, Lizet E; Mensenkamp, Arjen R; van Os, Theo A; Spruijt, Liesbeth; Redeker, Bert J W; Suerink, Manon; Vos, Yvonne J; Wagner, Anja; Wijnen, Juul T; Steyerberg, E W; Tops, Carli M J; van Wezel, Tom; Nielsen, Maartje
2017-11-17
Lynch syndrome (LS) patients are at high risk of developing colorectal cancer (CRC). Phenotypic variability might in part be explained by common susceptibility loci identified in Genome Wide Association Studies (GWAS). Previous studies focused mostly on MLH1, MSH2 and MSH6 carriers, with conflicting results. We aimed to determine the role of GWAS SNPs in PMS2 mutation carriers. A cohort study was performed in 507 PMS2 carriers (124 CRC cases), genotyped for 24 GWAS SNPs, including SNPs at 11q23.1 and 8q23.3. Hazard ratios (HRs) were calculated using a weighted Cox regression analysis to correct for ascertainment bias. Discrimination was assessed with a concordance statistic in a bootstrap cross-validation procedure. Individual SNPs only had non-significant associations with CRC occurrence with HRs lower than 2, although male carriers of allele A at rs1321311 (6p21.31) may have increased risk of CRC (HR = 2.1, 95% CI 1.2-3.0). A polygenic risk score (PRS) based on 24 HRs had an HR of 2.6 (95% CI 1.5-4.6) for the highest compared to the lowest quartile, but had no discriminative ability (c statistic 0.52). Previously suggested SNPs do not modify CRC risk in PMS2 carriers. Future large studies are needed for improved risk stratification among Lynch syndrome patients.
Gibson, Shannon L; Narayanan, Latha; Hegan, Denise Campisi; Buermeyer, Andrew B; Liskay, R Michael; Glazer, Peter M
2006-12-08
Inherited defects in genes associated with DNA mismatch repair (MMR) have been linked to familial colorectal cancer. Cells deficient in MMR are genetically unstable and demonstrate a tolerance phenotype in response to certain classes of DNA damage. Some sporadic human cancers also show abnormalities in MMR gene function, typically due to diminished expression of one of the MutL homologs, MLH1. Here, we report that overexpression of the MutL homolog, human PMS2, can also cause a disruption of the MMR pathway in mammalian cells, resulting in hypermutability and DNA damage tolerance. A mouse fibroblast cell line carrying a recoverable lambda phage shuttle vector for mutation detection was transfected with either a vector designed to express hPMS2 or with an empty vector control. Cells overexpressing hPMS2 were found to have elevated spontaneous mutation frequencies at the cII reporter gene locus. They also showed an increase in the level of mutations induced by the alkylating agent, methynitrosourea (MNU). Clonogenic survival assays demonstrated increased survival of the PMS2-overexpressing cells following exposure to MNU, consistent with the induction of a damage tolerance phenotype. Similar results were seen in cells expressing a mutant PMS2 gene, containing a premature stop codon at position 134 and representing a variant found in an individual with familial colon cancer. These results show that dysregulation of PMS2 gene expression can disrupt MMR function in mammalian cells and establish an additional carcinogenic mechanism by which cells can develop genetic instability and acquire resistance to cytotoxic cancer therapies.
2010-10-01
The proposed study uses the new MEPDG together with data available from LADOTDs Pavement Management System (PMS) and other data sources from LADOTDs main frame to evaluate typical flexible pavement structures currently used and to make changes ...
Directory of Open Access Journals (Sweden)
Qi Zheng
2015-09-01
Full Text Available Microbial fuel cells (MFCs are of increasing interest as bioelectrochemical systems for decomposing organic materials and converting chemical energy into electricity. The main challenge for this technology is that the low power and voltage of the devices restricts the use of MFCs in practical applications. In this paper, a power management system (PMS is developed to store the energy and export an increased voltage. The designed PMS successfully increases the low voltage generated by an individual MFC to a high potential of 5 V, capable of driving a wireless temperature and humidity sensor based on nRF24L01 data transmission modules. With the PMS, MFCs can intermittently power the sensor for data transmission to a remote receiver. It is concluded that even an individual MFC can supply the energy required to power the sensor and telemetry system with the designed PMS. The presented PMS can be widely used for unmanned environmental monitoring such as wild rivers, lakes, and adjacent water areas, and offers promise for further advances in MFC technology.
Zheng, Qi; Xiong, Lei; Mo, Bing; Lu, Weihong; Kim, Suki; Wang, Zhenyu
2015-09-11
Microbial fuel cells (MFCs) are of increasing interest as bioelectrochemical systems for decomposing organic materials and converting chemical energy into electricity. The main challenge for this technology is that the low power and voltage of the devices restricts the use of MFCs in practical applications. In this paper, a power management system (PMS) is developed to store the energy and export an increased voltage. The designed PMS successfully increases the low voltage generated by an individual MFC to a high potential of 5 V, capable of driving a wireless temperature and humidity sensor based on nRF24L01 data transmission modules. With the PMS, MFCs can intermittently power the sensor for data transmission to a remote receiver. It is concluded that even an individual MFC can supply the energy required to power the sensor and telemetry system with the designed PMS. The presented PMS can be widely used for unmanned environmental monitoring such as wild rivers, lakes, and adjacent water areas, and offers promise for further advances in MFC technology.
Nuclear import of human MLH1, PMS2, and MutLalpha: redundancy is the key.
Leong, Vivian; Lorenowicz, Jessica; Kozij, Natalie; Guarné, Alba
2009-08-01
DNA mismatch repair maintains genomic stability by correcting errors that have escaped polymerase proofreading. Defects on mismatch repair genes lead to an increased mutation rate, microsatellite instability and predisposition to human non-polyposis colorectal cancer (HNPCC). Human MutLalpha is a heterodimer formed by the interaction of MLH1 and PMS2 that coordinates a series of key events in mismatch repair. It has been proposed that nuclear import of MutLalpha may be the first regulatory step on the activation of the mismatch repair pathway. Using confocal microscopy and mismatch repair deficient cells, we have identified the sequence determinants that drive nuclear import of human MLH1, PMS2, and MutLalpha. Transient transfection of the individual proteins reveals that MLH1 has a bipartite and PMS2 has a single monopartite nuclear localization signal. Although dimerization is not required for nuclear localization, the MutLalpha heterodimer is imported more efficiently than the MLH1 or PMS2 monomers. Interestingly, the bipartite localization signal of MLH1 can direct import of MutLalpha even when PMS2 encompasses a mutated localization signal. Hence we conclude that the presence of redundant nuclear localization signals guarantees nuclear transport of MutLalpha and, consequently, efficient mismatch repair.
Kato, Aya; Sato, Naoki; Sugawara, Tae; Takahashi, Kazue; Kito, Masahiko; Makino, Kenichi; Sato, Toshiharu; Shimizu, Dai; Shirasawa, Hiromistu; Miura, Hiroshi; Sato, Wataru; Kumazawa, Yukiyo; Sato, Akira; Kumagai, Jin; Terada, Yukihiro
2016-06-01
Lynch syndrome (LS) is an autosomal-dominant inherited disorder mainly caused by a germline mutation in the DNA mismatch repair (MMR) genes (MLH1, MSH2, MSH6, and PMS2) and is associated with increased risk for various cancers, particularly colorectal cancer and endometrial cancer (EC). Women with LS account for 2% to 6% of EC patients; it is clinically important to identify LS in such individuals for predicting and/or preventing additional LS-associated cancers. PMS2 germline mutation (PMS2-LS) is the rarest contribution to LS etiology among the 4 LS-associated MMR germline mutations, and its detection is complicated. Therefore, prudent screening for PMS2-LS is important as it leads to an efficient LS identification strategy. Immunohistochemistry is recommended as a screening method for LS in EC. Isolated loss of PMS2 (IL-PMS2) expression is caused not only by PMS2-LS but also by MLH1 germline mutation or MLH1 promoter hypermethylation (MLH-PHM). This study aimed to determine the association between MLH1-PHM and IL-PMS2 to avoid inappropriate genetic analysis. We performed MLH1 methylation analysis and MLH1/PMS2 germline mutation testing on the IL-PMS2 cases. By performing MMR-immunohistochemistry on 360 unselected ECs, we could select 8 (2.2%) cases as IL-PMS2. Heterogenous MLH1 staining and MLH1-PHM were detected in 4 of 8 (50%) IL-PMS2 tumors. Of the 5 IL-PMS2 patients who underwent genetic analysis, 1 had PMS2 germline mutation with normal MLH1 expression (without MLH1-PHM), and no MLH1 germline mutation was detected. We suggest that MLH1 promoter methylation analysis for IL-PMS2 EC should be performed to exclude sporadic cases before further PMS2 genetic testing.
An intact Pms2 ATPase domain is not essential for male fertility
Fischer, Jared M; Dudley, Sandra; Miller, Ashleigh J; Liskay, R Michael
2015-01-01
The DNA mismatch repair (MMR) machinery in mammals plays critical roles in both mutation avoidance and spermatogenesis. Meiotic analysis of knockout mice of two different MMR genes, Mlh1 and Mlh3, revealed both male and female infertility associated with a defect in meiotic crossing over. In contrast, another MMR gene knockout, Pms2 (Pms2ko/ko), which contained a deletion of a portion of the ATPase domain, produced animals that were male sterile but female fertile. However, the meiotic phenot...
Increased sensitivity of p53-deficient cells to anticancer agents due to loss of Pms2
Fedier, A; Ruefenacht, U B; Schwarz, V A; Haller, U; Fink, D
2002-01-01
A large fraction of human tumours carries mutations in the p53 gene. p53 plays a central role in controlling cell cycle checkpoint regulation, DNA repair, transcription, and apoptosis upon genotoxic stress. Lack of p53 function impairs these cellular processes, and this may be the basis of resistance to chemotherapeutic regimens. By virtue of the involvement of DNA mismatch repair in modulating cytotoxic pathways in response to DNA damaging agents, we investigated the effects of loss of Pms2 on the sensitivity to a panel of widely used anticancer agents in E1A/Ha-Ras-transformed p53-null mouse fibroblasts either proficient or deficient in Pms2. We report that lack of the Pms2 gene is associated with an increased sensitivity, ranging from 2–6-fold, to some types of anticancer agents including the topoisomerase II poisons doxorubicin, etoposide and mitoxantrone, the platinum compounds cisplatin and oxaliplatin, the taxanes docetaxel and paclitaxel, and the antimetabolite gemcitabine. In contrast, no change in sensitivity was found after treatment with 5-fluorouracil. Cell cycle analysis revealed that both, Pms2-deficient and -proficient cells, retain the ability to arrest at the G2/M upon cisplatin treatment. The data indicate that the concomitant loss of Pms2 function chemosensitises p53-deficient cells to some types of anticancer agents, that Pms2 positively modulates cell survival by mechanisms independent of p53, and that increased cytotoxicity is paralleled by increased apoptosis. Tumour-targeted functional inhibition of Pms2 may be a valuable strategy for increasing the efficacy of anticancer agents in the treatment of p53-mutant cancers. British Journal of Cancer (2002) 87, 1027–1033. doi:10.1038/sj.bjc.6600599 www.bjcancer.com © 2002 Cancer Research UK PMID:12434296
Schmidt, Katja; Weber, Nicole; Steiner, Meir; Meyer, Nadin; Dubberke, Anne; Rutenberg, David; Hellhammer, Juliane
2018-04-01
Many women experience emotional and physical symptoms around the time of ovulation and more so before menstruation interfering with their daily normal life also known as premenstrual syndrome (PMS). Recent observational data suggest that supplementation with Lipogen's phosphatidylserine (PS) and phosphatidic acid (PA) complex (PAS) alleviates these PMS symptoms. The aim of this study was to confirm these observations on the effects of PAS on PMS symptom severity within a controlled clinical trial setting. Forty women aged 18-45 years with a diagnosis of PMS were assigned to either take PAS (containing 400 mg PS & 400 mg PA per day) or a matching placebo. The study comprised 5 on-site visits including 1 baseline menstrual cycle followed by 3 treatment cycles. Treatment intake was controlled for by using an electronic device, the Medication Event Monitoring System (MEMS ® ). Primary outcome of the study was the PMS symptoms severity as assessed by using the Daily Record of Severity of Problems (DRSP). Further, SIPS questionnaire (a German version of the Premenstrual Symptoms Screening Tool (PSST)), salivary hormone levels (cortisol awakening response (CAR) and evening cortisol levels) as well as serum levels (cortisol, estradiol, progesterone and corticosteroid binding globulin (CBG)) were assessed. PMS symptoms as assessed by the DRSP Total score showed a significantly better improvement (p = 0.001) over a 3 cycles PAS intake as compared to placebo. In addition, PAS treated women reported a greater improvement in physical (p = 0.002) and depressive symptoms (p = 0.068). They also reported a lower reduction of productivity (p = 0.052) and a stronger decrease in interference with relationships with others (p = 0.099) compared to the placebo group. No other DRSP scale or item showed significant results. Likewise, the reduction in the number of subjects fulfilling PMS or premenstrual dysphoric disorder (PMDD) criteria as classified by the SIPS did not
Ten Broeke, S W; van Bavel, T C; Jansen, A M L; Gómez-García, E; Hes, F J; van Hest, L P; Letteboer, T G W; Olderode-Berends, M J W; Ruano, D; Spruijt, L; Suerink, M; Tops, C M; van Eijk, R; Morreau, H; van Wezel, T; Nielsen, M
2018-05-11
Germline variants in the mismatch repair genes MLH1, MSH2 (EPCAM), MSH6, or PMS2 cause Lynch syndrome. Patients with these variants have an increased risk of developing colorectal cancers (CRCs) that differ from sporadic CRCs in genetic and histologic features. It has been a challenge to study CRCs associated with PMS2 variants (PMS2-associated CRCs) because these develop less frequently and in patients of older ages than colorectal tumors with variants in the other mismatch repair genes. We analyzed 20 CRCs associated with germline variants in PMS2, 22 sporadic CRCs, 18 CRCs with germline variants in MSH2, and 24 CRCs from patients with germline variants in MLH1. Tumor tissue blocks were collected from Dutch pathology departments in 2017. After extraction of tumor DNA, we used a platform designed to detect approximately 3000 somatic hotspot variants in 55 genes (including KRAS, APC, CTNNB1, and TP53). Somatic variant frequencies were compared using the Fisher's exact test. None of the PMS2-associated CRCs contained any somatic variants in the catenin beta 1 gene (CTNNB1), which encodes β-catenin, whereas 14/24 MLH1-associated CRCs (58%) contained variants in CTNNB1. Half of PMS2-associated CRCs contained KRAS variants, but only 20% of these were in hotspots that encoded G12D or G13D. These hotspot variants occurred more frequently in CRCs associated with variants in MLH1 (37.5%, P=.44) and MSH2 (and 71.4%, P=.035) than with variants in PMS2. In a genetic analysis of 84 colorectal tumors, we found tumors from patients with PMS2-associated Lynch syndrome to be distinct from colorectal tumors associated with defects in other mismatch repair genes. This might account for differences in development and less frequent occurrence. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
van Die, Margaret Diana; Bone, Kerry M; Burger, Henry G; Reece, John E; Teede, Helena J
2009-09-01
It has been suggested that some of the symptoms typically attributed to menopause may be more related to premenstrual syndrome (PMS) than menopause, as perimenopausal women appear to be more prone to PMS-like symptoms, or at least to tolerate them less well. The objective of this study was to evaluate the effectiveness of a phytotherapeutic intervention comprising a combination of Hypericum perforatum (St. John's wort) and Vitex agnus-castus (chaste tree/berry) in the management of PMS-like symptoms in perimenopausal women. A double-blind, randomized, placebo-controlled parallel trial was conducted over 16 weeks on menopause-related symptoms. Data on PMS-like symptoms were collected at 4-weekly intervals from a small subgroup of late-perimenopausal women (n = 14) participating in this study. The primary endpoint was PMS scores measured on the Abrahams Menstrual Symptoms Questionnaire, comprising the subclusters of PMS-A (anxiety), PMS-D (depression), PMS-H (hydration), and PMS-C (cravings). Herbal combination therapy or placebo tablets were administered twice daily. At the end of the 16-week treatment phase, analyses of covariance showed the herbal combination to be superior to placebo for total PMS-like scores (p = 0.02), PMS-D (p = 0.006), and PMS-C clusters (p = 0.027). The active treatment group also showed significant reductions in the anxiety (p = 0.003) and hydration (p = 0.002) clusters, using paired-samples t tests. Results of trend analyses showed significant treatment group effects across the five phases for total PMS and all subscales, all in the clinically expected direction. No significant trends were evident in the placebo group. These results suggest a potentially significant clinical application for this phytotherapeutic combination in PMS-like symptoms among perimenopausal women. Further research is warranted through a randomized, controlled trial dedicated to investigation of these symptoms.
Shinsato, Yoshinari; Furukawa, Tatsuhiko; Yunoue, Shunji; Yonezawa, Hajime; Minami, Kentarou; Nishizawa, Yukihiko; Ikeda, Ryuji; Kawahara, Kohichi; Yamamoto, Masatatsu; Hirano, Hirofumi; Tokimura, Hiroshi; Arita, Kazunori
2013-12-01
Although there is a relationship between DNA repair deficiency and temozolomide (TMZ) resistance in glioblastoma (GBM), it remains unclear which molecule is associated with GBM recurrence. We isolated three TMZ-resistant human GBM cell lines and examined the expression of O6-methylguanine-DNA methyltransferase (MGMT) and mismatch repair (MMR) components. We used immunohistochemical analysis to compare MutL homolog 1 (MLH1), postmeiotic segregation increased 2 (PMS2) and MGMT expression in primary and recurrent GBM specimens obtained from GBM patients during TMZ treatment. We found a reduction in MLH1 expression and a subsequent reduction in PMS2 protein levels in TMZ-resistant cells. Furthermore, MLH1 or PMS2 knockdown confered TMZ resistance. In recurrent GBM tumours, the expression of MLH1 and PMS2 was reduced when compared to primary tumours.
Li, Lili; Hamel, Nancy; Baker, Kristi; McGuffin, Michael J; Couillard, Martin; Gologan, Adrian; Marcus, Victoria A; Chodirker, Bernard; Chudley, Albert; Stefanovici, Camelia; Durandy, Anne; Hegele, Robert A; Feng, Bing-Jian; Goldgar, David E; Zhu, Jun; De Rosa, Marina; Gruber, Stephen B; Wimmer, Katharina; Young, Barbara; Chong, George; Tischkowitz, Marc D; Foulkes, William D
2015-05-01
Inherited mutations in DNA mismatch repair genes predispose to different cancer syndromes depending on whether they are mono-allelic or bi-allelic. This supports a causal relationship between expression level in the germline and phenotype variation. As a model to study this relationship, our study aimed to define the pathogenic characteristics of a recurrent homozygous coding variant in PMS2 displaying an attenuated phenotype identified by clinical genetic testing in seven Inuit families from Northern Quebec. Pathogenic characteristics of the PMS2 mutation NM_000535.5:c.2002A>G were studied using genotype-phenotype correlation, single-molecule expression detection and single genome microsatellite instability analysis. This PMS2 mutation generates a de novo splice site that competes with the authentic site. In homozygotes, expression of the full-length protein is reduced to a level barely detectable by conventional diagnostics. Median age at primary cancer diagnosis is 22 years among 13 NM_000535.5:c.2002A>G homozygotes, versus 8 years in individuals carrying bi-allelic truncating mutations. Residual expression of full-length PMS2 transcript was detected in normal tissues from homozygotes with cancers in their 20s. Our genotype-phenotype study of c.2002A>G illustrates that an extremely low level of PMS2 expression likely delays cancer onset, a feature that could be exploited in cancer preventive intervention. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Zighelboim, Israel; Powell, Matthew A; Babb, Sheri A; Whelan, Alison J; Schmidt, Amy P; Clendenning, Mark; Senter, Leigha; Thibodeau, Stephen N; de la Chapelle, Albert; Goodfellow, Paul J
2009-01-01
We assessed mismatch repair by immunohistochemistry (IHC) and microsatellite instability (MSI) analysis in an early onset endometrial cancer and a sister's colon cancer. We demonstrated high-level MSI and normal expression for MLH1, MSH2 and MSH6. PMS2 failed to stain in both tumors, strongly implicating a PMS2 defect. This family did not meet clinical criteria for Lynch syndrome. However, early onset endometrial cancers in the proband and her sister, a metachronous colorectal cancer in the sister as well as MSI in endometrial and colonic tumors suggested a heritable mismatch repair defect. PCR-based direct exonic sequencing and multiplex ligation-dependent probe amplification (MLPA) were undertaken to search for PMS2 mutations in the germline DNA from the proband and her sister. No mutation was identified in the PMS2 gene. However, PMS2 exons 3, 4, 13, 14, 15 were not evaluated by MLPA and as such, rearrangements involving those exons cannot be excluded. Clinical testing for MLH1 and MSH2 mutation revealed a germline deletion of MLH1 exons 14 and 15. This MLH1 germline deletion leads to an immunodetectable stable C-terminal truncated MLH1 protein which based on the IHC staining must abrogate PMS2 stabilization. To the best of our knowledge, loss of PMS2 in MLH1 truncating mutation carriers that express MLH1 in their tumors has not been previously reported. This family points to a potential limitation of IHC-directed gene testing for suspected Lynch syndrome and the need to consider comprehensive MLH1 testing for individuals whose tumors lack PMS2 but for whom PMS2 mutations are not identified.
A Dimensional Analysis of the use of Performance Measurement Systems in Credit Cooperatives
Directory of Open Access Journals (Sweden)
Elizandra Severgnini
2017-12-01
Full Text Available The appropriate use of organizational performance information influences anorganization´s results and capabilities. In the literature, there are four dimensions to the use of the performance measurement system (PMS such as monitoring, attention focus, strategic decision-making, and legitimacy. Although the use of PMS is frequent in private enterprises, few studies have been concerned with analyzing the reasons and adequacies of PMS in credit cooperatives (CC. Thus, the paper’s main goal is to analyze the ways in which PMS is used and their respective objectives in CC. In field research, we investigate three cooperatives representing the largest organizations in Brazil. By means of a bibliometric study and qualitative inquiry with multiple companies (multiple cases, we interviewed their executives. The bibliometric study provided subsidies to propose a classification of PMS, as well as an analysis of similarities and divergences between the classifications presented in the literature. In the qualitative inquiry, four dimensions of PMS were observed and confirmed in the CC´s management. In addition, based on the interviews with the executives, two new dimensions of the PMS were proposed, such as Incentives, Rewards, and Human Valorization.
Ganster, Christina; Wernstedt, Annekatrin; Kehrer-Sawatzki, Hildegard; Messiaen, Ludwine; Schmidt, Konrad; Rahner, Nils; Heinimann, Karl; Fonatsch, Christa; Zschocke, Johannes; Wimmer, Katharina
2010-05-01
Sequence exchange between PMS2 and its pseudogene PMS2CL, embedded in an inverted duplication on chromosome 7p22, has been reported to be an ongoing process that leads to functional PMS2 hybrid alleles containing PMS2- and PMS2CL-specific sequence variants at the 5'-and the 3'-end, respectively. The frequency of PMS2 hybrid alleles, their biological significance, and the mechanisms underlying their formation are largely unknown. Here we show that overall hybrid alleles account for one-third of 384 PMS2 alleles analyzed in individuals of different ethnic backgrounds. Depending on the population, 14-60% of hybrid alleles carry PMS2CL-specific sequences in exons 13-15, the remainder only in exon 15. We show that exons 13-15 hybrid alleles, named H1 hybrid alleles, constitute different haplotypes but trace back to a single ancient intrachromosomal recombination event with crossover. Taking advantage of an ancestral sequence variant specific for all H1 alleles we developed a simple gDNA-based polymerase chain reaction (PCR) assay that can be used to identify H1-allele carriers with high sensitivity and specificity (100 and 99%, respectively). Because H1 hybrid alleles harbor missense variant p.N775S of so far unknown functional significance, we assessed the H1-carrier frequency in 164 colorectal cancer patients. So far, we found no indication that the variant plays a major role with regard to cancer susceptibility. (c) 2010 Wiley-Liss, Inc.
Top Performing PMs: How DAU Develops Them
2015-12-01
online, while intermediate courses feature a combination of online prerequisites followed by classroom training. Advanced PM courses use teams of...hours of online instruction and 27.5 classroom days. For major acquisition PMs, 70 additional classroom days of specialized training (PMT 401 and...training and experience is that creative , informed thought is necessary to optimize the structure of a program. DAU embeds principles of critical
A prototype detection system for atmospheric monitoring of xenon radioisotopes
Czyz, Steven A.; Farsoni, Abi T.; Ranjbar, Lily
2018-03-01
The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135Xe and 133/133mXe, have been detailed previously. This paper presents recent measurements of 133/133mXe and 131mXe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135Xe, 133/133mXe, and 131mXe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m3 for 131mXe, 133Xe, and 133mXe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). The system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.
Goverde, A; Spaander, M C W; Nieboer, D; van den Ouweland, A M W; Dinjens, W N M; Dubbink, H J; Tops, C J; Ten Broeke, S W; Bruno, M J; Hofstra, R M W; Steyerberg, E W; Wagner, A
2018-07-01
Until recently, no prediction models for Lynch syndrome (LS) had been validated for PMS2 mutation carriers. We aimed to evaluate MMRpredict and PREMM5 in a clinical cohort and for PMS2 mutation carriers specifically. In a retrospective, clinic-based cohort we calculated predictions for LS according to MMRpredict and PREMM5. The area under the operator receiving characteristic curve (AUC) was compared between MMRpredict and PREMM5 for LS patients in general and for different LS genes specifically. Of 734 index patients, 83 (11%) were diagnosed with LS; 23 MLH1, 17 MSH2, 31 MSH6 and 12 PMS2 mutation carriers. Both prediction models performed well for MLH1 and MSH2 (AUC 0.80 and 0.83 for PREMM5 and 0.79 for MMRpredict) and fair for MSH6 mutation carriers (0.69 for PREMM5 and 0.66 for MMRpredict). MMRpredict performed fair for PMS2 mutation carriers (AUC 0.72), while PREMM5 failed to discriminate PMS2 mutation carriers from non-mutation carriers (AUC 0.51). The only statistically significant difference between PMS2 mutation carriers and non-mutation carriers was proximal location of colorectal cancer (77 vs. 28%, p PMS2 mutation carriers (AUC 0.77) and overall (AUC 0.81 vs. 0.72). We validated these results in an external cohort of 376 colorectal cancer patients, including 158 LS patients. MMRpredict and PREMM5 cannot adequately identify PMS2 mutation carriers. Adding location of colorectal cancer to PREMM5 may improve the performance of this model, which should be validated in larger cohorts.
Clendenning, Mark; Walsh, Michael D; Gelpi, Judith Balmana; Thibodeau, Stephen N; Lindor, Noralane; Potter, John D; Newcomb, Polly; LeMarchand, Loic; Haile, Robert; Gallinger, Steve; Hopper, John L; Jenkins, Mark A; Rosty, Christophe; Young, Joanne P; Buchanan, Daniel D
2013-09-01
Current screening practices have been able to identify PMS2 mutations in 78 % of cases of colorectal cancer from the Colorectal Cancer Family Registry (Colon CFR) which showed solitary loss of the PMS2 protein. However the detection of large-scale deletions in the 3' end of the PMS2 gene has not been possible due to technical difficulties associated with pseudogene sequences. Here, we utilised a recently described MLPA/long-range PCR-based approach to screen the remaining 22 % (n = 16) of CRC-affected probands for mutations in the 3' end of the PMS2 gene. No deletions encompassing any or all of exons 12 through 15 were identified; therefore, our results suggest that 3' deletions in PMS2 are not a frequent occurrence in such families.
One More Look at PMS: Implications for Women of a New Focus on an Old Problem.
Ames, Natalie
1988-01-01
This article surveys research and opinion on Premenstrual Syndrome (PMS), its causes, symptoms, and treatment and the implications of each for women. Researchers and medical service providers are urged to consider all factors--physical, social, and emotional--which play a role in causing PMS before diagnosing and treating the disorder. (JL)
JST Thesaurus Headwords and Synonyms: PMS [MeCab user dictionary for science technology term[Archive
Lifescience Database Archive (English)
Full Text Available MeCab user dictionary for science technology term PMS 名詞 一般 * * * * 医薬品市販後調査 イヤクヒンシハンゴチョウサ イヤクヒンシハンゴチョーサ Thesaurus2015 200906079217411060 C LS41 UNKNOWN_1 PMS
Jackson, Christine; Pearson, Brenda; Girdler, Susan; Johnson, Jacqueline; Hamer, Robert M; Killenberg, Susan; Meltzer-Brody, Samantha
2015-11-01
Premenstrual dysphoric disorder (PMDD), a more severe form of premenstrual syndrome (PMS), afflicts 5-8% of reproductive age women and results in significant functional impairment. We conducted a double-blind, placebo-controlled trial of adjunctive quetiapine in patients with PMS/PMDD who had inadequate response to selective serotonin reuptake inhibitor/serotonin-norepinephrine reuptake inhibitor therapy for their symptoms. A PMS/PMDD diagnosis was confirmed by 2-month prospective diagnostic assessment of PMS/PMDD using the Prospective Record of the Impact and Severity of Premenstrual Symptoms (PRISM) calendar. Women were randomized equally to receive quetiapine sustained-release (SR) or placebo (25-mg starting dose) during the luteal phase for 3 months. Outcome variables included the Hamilton Depression and Anxiety Scales, Clinical Global Impression Scale, and PRISM. Twenty women were enrolled in the treatment phase. Although the study was underpowered, greater reductions in luteal phase mood ratings were observed in the quetiapine group on the 17-item Hamilton Depression Rating Scale, Clinical Global Impression improvement rating, and PRISM daily score. The quetiapine group showed most improvement in symptoms of mood lability, anxiety, and irritability. This small double-blind study suggests that adjunctive treatment with quetiapine SR may be a useful addition to selective serotonin reuptake inhibitor therapy in women with PMS/PMDD by reducing symptoms and improving quality of life. Copyright © 2015 John Wiley & Sons, Ltd.
Bernstein, Harris; Prasad, Anil; Holubec, Hana; Bernstein, Carol; Payne, Claire M; Ramsey, Lois; Dvorakova, Katerina; Wilson, Megan; Warneke, James A; Garewal, Harinder
2006-06-01
Pms2 protein is a component of the DNA mismatch repair complex responsible both for post-replication correction of DNA nucleotide mispairs and for early steps in apoptosis. Germline mutations in DNA mismatch repair genes give rise to hereditary non-polyposis colon cancer, which accounts for about 4% of colon cancers. However, little is known about the expression of mismatch repair proteins in relation to sporadic colon cancer, which accounts for the great majority of colon cancers. Multiple samples were taken from the non-neoplastic flat mucosa of colon resections from patients with no colonic neoplasia, a tubulovillous adenoma, or an adenocarcinoma. Expression of Pms2 was assessed using semiquantitative immunohistochemistry. Apoptosis was assessed in polychrome-stained epoxy sections using morphologic criteria. Samples from patients without colonic neoplasia had moderate to strong staining for Pms2 in cell nuclei at the base of crypts, while samples from 2 of the 3 colons with a tubulovillous adenoma, and from 6 of the 10 colons with adenocarcinomas, showed reduced Pms2 expression. Samples from patients with an adenocarcinoma that had reduced Pms2 expression also exhibited reduced apoptosis capability in nearby tissue samples, evidenced when this paired tissue was stressed ex vivo with bile acid. Reduced Pms2 expression in the colonic mucosa may be an early step in progression to colon cancer. This reduction may cause decreased mismatch repair, increased genetic instability, and/or reduced apoptotic capability. Immunohistochemical determination of reduced Pms2 expression, upon further testing, may prove to be a promising early biomarker of risk of progression to malignancy.
De Vos, Michel; Hayward, Bruce E.; Picton, Susan; Sheridan, Eamonn; Bonthron, David T.
2004-01-01
We investigated a family with an autosomal recessive syndrome of café-au-lait patches and childhood malignancy, notably supratentorial primitive neuroectodermal tumor. There was no cancer predisposition in heterozygotes; nor was there bowel cancer in any individual. However, autozygosity mapping indicated linkage to a region of 7p22 surrounding the PMS2 mismatch-repair gene. Sequencing of genomic PCR products initially failed to identify a PMS2 mutation. Genome searches then revealed a previo...
The prevalence, impairment, impact, and burden of premenstrual dysphoric disorder (PMS/PMDD).
Halbreich, Uriel; Borenstein, Jeff; Pearlstein, Terry; Kahn, Linda S
2003-08-01
Currently it is estimated that 3-8% of women of reproductive age meet strict criteria for premenstrual dysphoric disorder (PMDD). Assessment of published reports demonstrate that the prevalence of clinically relevant dysphoric premenstrual disorder is probably higher. 13-18% of women of reproductive age may have premenstrual dysphoric symptoms severe enough to induce impairment and distress, though the number of symptoms may not meet the arbitrary count of 5 symptoms on the PMDD list. The impairment and lowered quality of life for PMDD is similar to that of dysthymic disorder and is not much lower than major depressive disorder. Nevertheless, PMS/PMDD is still under-recognized in large published epidemiological studies, as well as assessments of burden of disease. It is demonstrated here that the burden of PMS/PMDD as well as the disability adjusted life years (DALY) lost due to this repeated-cyclic disorder is in the same magnitude as major recognized disorders. Appropriate recognition of the disorder and its impact should lead to treatment of more women with PMS/PMDD. Efficacious treatments are available. They should reduce individual suffering and impact on family, society, and economy.
Fang, Jugao; Lei, Wenbin; Huang, Xiaoming; Li, Pingdong; Chen, Xiaohong; Zhu, Xiaolin; Wen, Weiping; Li, Huabin
2012-02-01
To evaluate the expression of mismatch repair gene PMS2 in human nasopharyngeal carcinoma (NPC) tissues and evaluate the effect of glycogen synthase kinase (GSK)-3β on PMS2 production in vivo and in vitro. The expression of PMS2 and inactivated phosphorylated GSK-3β(s9) was examined by immunohistochemical staining in 25 NPC tissues and the relation was determined by correlation analysis. The effect of GSK-3β transfection in CNE-2 cells on PMS2 production as well as cell apoptosis and chemosensitization were evaluated using small interference RNA (siRNA), immunoblotting and flow cytometric analysis in vitro. The expression of inactivated phosphorylated GSK-3β(s9) was found to negative correlated with PMS2 in vivo. And transfected GSK-3β was found to be able to enhance PMS2 production, and increase cell apoptosis in CNE-2 cells in combination with cisplatin administration in vitro. Inactivation of GSK-3β might be important for NPC tumorgenesis through negatively regulating PMS2 production, and enhanced PMS2 production by GSK-3β is beneficial for understanding the NPC tumorgenesis and developing potential strategy for future therapy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Stewart, Colin J R; Pearn, Amy; Pachter, Nicholas; Tan, Adeline
2018-04-30
The observation of peritumoral granulomatous reactions (PGRs) in two endometrial carcinomas (ECs) with a PMS2-deficient/MLH1-intact expression pattern led us to investigate whether PGRs in EC were specifically associated with DNA mismatch repair (MMR) protein deficiency, particularly PMS2 loss. Hysterectomy specimens from 22 MMR protein-intact and 54 MMR protein-deficient ECs were reviewed with specific attention to the presence of a PGR and a tumour-associated lymphoid reaction [including tumour-infiltrating lymphocytes (TILs) and stromal lymphoid infiltrates]. The MMR protein-deficient ECs included 22 cases with combined MLH1/PMS2 loss, 11 with combined MSH2/MSH6 loss, 11 with isolated MSH6 loss, and 10 with PMS2 loss but intact MLH1 staining (including the two 'index' cases). Overall, PGRs were identified in seven of 54 (13%) MMR protein-deficient ECs, five of which showed a PMS2-deficient/MLH1-intact immunophenotype; three of these patients had germline PMS2 mutations and one additional patient had a germline MSH6 mutation. None of the MMR protein-intact tumours showed a PGR. Although five of the seven PGR-positive ECs had a high-grade histological component, six were stage I. Most ECs with PGRs also showed TILs and stromal lymphoid reactions, similarly to MMR protein-deficient ECs in general. MMR protein-deficient ECs, particularly those with PMS2 loss, occasionally show PGRs in addition to stromal lymphoid infiltrates and TILs. Therefore, PGRs could be considered to constitute a histological prompt for consideration of Lynch syndrome. The potential prognostic significance of PGRs in EC requires further study. © 2018 John Wiley & Sons Ltd.
Rossella, M.; Bariani, S.; Barnaba, O.; Cattaneo, P. W.; Cervi, T.; Menegolli, A.; Nardò, R.; Prata, M. C.; Romano, E.; Scagliotti, C.; Simonetta, M.; Vercellati, F.
2017-02-01
The MEG II Timing Counter will measure the positron time of arrival with a resolution of 30 ps relying on two arrays of scintillator pixels read out by 6144 Silicon Photomultipliers (SiPMs) from AdvanSiD. They must be characterized, measuring their breakdown voltage, to assure that the gains of the SiPMs of each pixel are as uniform as possible, to maximize the pixel resolution. To do this an automatic test system that can measure sequentially the parameters of 32 devices has been developed.
Clendenning, Mark; Walsh, Michael D; Gelpi, Judith Balmana; Thibodeau, Stephen N.; Lindor, Noralane; Potter, John D.; Newcomb, Polly; LeMarchand, Loic; Haile, Robert; Gallinger, Steve; Hopper, John L.; Jenkins, Mark A.; Rosty, Christophe; Young, Joanne P.; Buchanan, Daniel D.
2013-01-01
Current screening practices have been able to identify PMS2 mutations in 78% of cases of colorectal cancer from the Colorectal Cancer Family Registry (Colon CFR) which showed solitary loss of the PMS2 protein. However the detection of large-scale deletions in the 3′ end of the PMS2 gene has not been possible due to technical difficulties associated with pseudogene sequences. Here, we utilised a recently described MLPA/long-range PCR-based approach to screen the remaining 22% (n = 16) of CRC-affected probands for mutations in the 3′ end of the PMS2 gene. No deletions encompassing any or all of exons 12 through 15 were identified; therefore, our results suggest that 3′ deletions in PMS2 are not a frequent occurrence in such families. PMID:23288611
Directory of Open Access Journals (Sweden)
Soheila Samieipour
2016-09-01
Full Text Available Background Premenstrual syndrome (PMS is a combination of physical, psychological and emotional symptoms that occur periodically before menstruation and disappear with the onset of menstruation. There are some therapeutic methods mostly according to the clinical trials that reduce the prevalence and intensity of symptoms of PMS by unknown mechanisms. This study aimed to investigate the effects of Calcium and vitamin B1 on Premenstrual syndrome among female students. Materials and Methods: This is a triple-blind clinical trial conducted on 210 female students living in dormitories of Ilam University of Medical Sciences who had PMS. PMS symptoms questionnaire was used to investigate the symptoms. Participants were assigned in 3 groups of 70 people with the following regimen: group 1 received one pill containing 100 milligrams vitamin B1, group 2 received Calcium pills and group 3 received placebo. The participants in all groups took medicines for 2 months and then reported the intensity of their symptoms by the questionnaire. The collected data was analyzed by descriptive and inferential statistics, using SPSS-16. Results: In groups receiving vitamin B1, Calcium and placebo, the intensity of physical and psychological symptoms as well as general symptoms of PMS had a remarkable reduction (P
Talseth-Palmer, Bente A; McPhillips, Mary; Groombridge, Claire; Spigelman, Allan; Scott, Rodney J
2010-05-21
Approximately 10% of Lynch syndrome families have a mutation in MSH6 and fewer families have a mutation in PMS2. It is assumed that the cancer incidence is the same in families with mutations in MSH6 as in families with mutations in MLH1/MSH2 but that the disease tends to occur later in life, little is known about families with PMS2 mutations. This study reports on our findings on mutation type, cancer risk and age of diagnosis in MSH6 and PMS2 families. A total of 78 participants (from 29 families) with a mutation in MSH6 and 7 participants (from 6 families) with a mutation in PMS2 were included in the current study. A database of de-identified patient information was analysed to extract all relevant information such as mutation type, cancer incidence, age of diagnosis and cancer type in this Lynch syndrome cohort. Cumulative lifetime risk was calculated utilising Kaplan-Meier survival analysis. MSH6 and PMS2 mutations represent 10.3% and 1.9%, respectively, of the pathogenic mutations in our Australian Lynch syndrome families. We identified 26 different MSH6 and 4 different PMS2 mutations in the 35 families studied. We report 15 novel MSH6 and 1 novel PMS2 mutations. The estimated cumulative risk of CRC at age 70 years was 61% (similar in males and females) and 65% for endometrial cancer in MSH6 mutation carriers. The risk of developing CRC is different between males and females at age 50 years, which is 34% for males and 21% for females. Novel MSH6 and PMS2 mutations are being reported and submitted to the current databases for identified Lynch syndrome mutations. Our data provides additional information to add to the genotype-phenotype spectrum for both MSH6 and PMS2 mutations.
A Data-Driven Reliability Estimation Approach for Phased-Mission Systems
Directory of Open Access Journals (Sweden)
Hua-Feng He
2014-01-01
Full Text Available We attempt to address the issues associated with reliability estimation for phased-mission systems (PMS and present a novel data-driven approach to achieve reliability estimation for PMS using the condition monitoring information and degradation data of such system under dynamic operating scenario. In this sense, this paper differs from the existing methods only considering the static scenario without using the real-time information, which aims to estimate the reliability for a population but not for an individual. In the presented approach, to establish a linkage between the historical data and real-time information of the individual PMS, we adopt a stochastic filtering model to model the phase duration and obtain the updated estimation of the mission time by Bayesian law at each phase. At the meanwhile, the lifetime of PMS is estimated from degradation data, which are modeled by an adaptive Brownian motion. As such, the mission reliability can be real time obtained through the estimated distribution of the mission time in conjunction with the estimated lifetime distribution. We demonstrate the usefulness of the developed approach via a numerical example.
Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli
2016-10-01
GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.
Herkert, Johanna C; Niessen, Renée C; Olderode-Berends, Maria J W; Veenstra-Knol, Hermine E; Vos, Yvonne J; van der Klift, Heleen M; Scheenstra, Rene; Tops, Carli M J; Karrenbeld, Arend; Peters, Frans T M; Hofstra, Robert M W; Kleibeuker, Jan H; Sijmons, Rolf H
2011-05-01
Bi-allelic germline mutations of one of the DNA mismatch repair genes, so far predominantly found in PMS2, cause constitutional MMR-deficiency syndrome. This rare disorder is characterised by paediatric intestinal cancer and other malignancies. We report the clinical, immunohistochemical and genetic characterisation of four families with bi-allelic germline PMS2 mutations. We present an overview of the published gastrointestinal manifestations of CMMR-D syndrome and propose recommendations for gastro-intestinal screening. The first proband developed a cerebral angiosarcoma at age 2 and two colorectal adenomas at age 7. Genetic testing identified a complete PMS2 gene deletion and a frameshift c.736_741delinsTGTGTGTGAAG (p.Pro246CysfsX3) mutation. In the second family, both the proband and her brother had multiple intestinal adenomas, initially wrongly diagnosed as familial adenomatous polyposis. A splice site c.2174+1G>A, and a missense c.137G>T (p.Ser46Ile) mutation in PMS2 were identified. The third patient was diagnosed with multiple colorectal adenomas at age 11; he developed a high-grade dysplastic colorectal adenocarcinoma at age 21. Two intragenic PMS2 deletions were found. The fourth proband developed a cerebral anaplastic ganglioma at age 9 and a high-grade colerectal dysplastic adenoma at age 10 and carries a homozygous c.2174+1G>A mutation. Tumours of all patients showed microsatellite instability and/or loss of PMS2 expression. Our findings show the association between bi-allelic germline PMS2 mutations and severe childhood-onset gastrointestinal manifestations, and support the notion that patients with early-onset gastrointestinal adenomas and cancer should be investigated for CMMR-D syndrome. We recommend yearly follow-up with colonoscopy from age 6 and simultaneous video-capsule small bowel enteroscopy from age 8. Copyright © 2011 Elsevier Ltd. All rights reserved.
Jackson, Carl-Christian; Holter, Spring; Pollett, Aaron; Clendenning, Mark; Chou, Shirley; Senter, Leigha; Ramphal, Raveena; Gallinger, Steven; Boycott, Kym
2008-06-01
A 14-year-old male presented with a T4 sigmoid adenocarcinoma, PMS2 protein and high frequency microsatellite instability. Germline analysis identified biallelic PMS2 missense mutations. A new cancer syndrome caused by biallelic mutations in the mismatch repair genes, including PMS2, is now emerging and is characterized by café-au-lait macules, colonic polyps and a distinctive tumor spectrum. (c) 2007 Wiley-Liss, Inc.
Plys, Aaron J.; Rogacheva, Maria V.; Greene, Eric C.; Alani, Eric
2012-01-01
DNA mismatch repair (MMR) models have proposed that MSH proteins identify DNA polymerase errors while interacting with the DNA replication fork. MLH proteins (primarily Mlh1-Pms1 in baker’s yeast) then survey the genome for lesion-bound MSH proteins. The resulting MSH-MLH complex formed at a DNA lesion initiates downstream steps in repair. MLH proteins act as dimers and contain long (20 – 30 nanometers) unstructured arms that connect two terminal globular domains. These arms can vary between 100 to 300 amino acids in length, are highly divergent between organisms, and are resistant to amino acid substitutions. To test the roles of the linker arms in MMR, we engineered a protease cleavage site into the Mlh1 linker arm domain of baker’s yeast Mlh1-Pms1. Cleavage of the Mlh1 linker arm in vitro resulted in a defect in Mlh1-Pms1 DNA binding activity, and in vivo proteolytic cleavage resulted in a complete defect in MMR. We then generated a series of truncation mutants bearing Mlh1 and Pms1 linker arms of varying lengths. This work revealed that MMR is greatly compromised when portions of the Mlh1 linker are removed, whereas repair is less sensitive to truncation of the Pms1 linker arm. Purified complexes containing truncations in Mlh1 and Pms1 linker arms were analyzed and found to have differential defects in DNA binding that also correlated with the ability to form a ternary complex with Msh2-Msh6 and mismatch DNA. These observations are consistent with the unstructured linker domains of MLH proteins providing distinct interactions with DNA during MMR. PMID:22659005
Design of project management system for 10 MW high temperature gas-cooled test reactor
International Nuclear Information System (INIS)
Zhu Yan; Xu Yuanhui
1998-01-01
A framework of project management information system (MIS) for 10 MW high temperature gas-cooled test reactor is introduced. Based on it, the design of nuclear project management information system and project monitoring system (PMS) are given. Additionally, a new method of developing MIS and Decision Support System (DSS) has been tried
Directory of Open Access Journals (Sweden)
Talseth-Palmer Bente A
2010-05-01
Full Text Available Abstract Background Approximately 10% of Lynch syndrome families have a mutation in MSH6 and fewer families have a mutation in PMS2. It is assumed that the cancer incidence is the same in families with mutations in MSH6 as in families with mutations in MLH1/MSH2 but that the disease tends to occur later in life, little is known about families with PMS2 mutations. This study reports on our findings on mutation type, cancer risk and age of diagnosis in MSH6 and PMS2 families. Methods A total of 78 participants (from 29 families with a mutation in MSH6 and 7 participants (from 6 families with a mutation in PMS2 were included in the current study. A database of de-identified patient information was analysed to extract all relevant information such as mutation type, cancer incidence, age of diagnosis and cancer type in this Lynch syndrome cohort. Cumulative lifetime risk was calculated utilising Kaplan-Meier survival analysis. Results MSH6 and PMS2 mutations represent 10.3% and 1.9%, respectively, of the pathogenic mutations in our Australian Lynch syndrome families. We identified 26 different MSH6 and 4 different PMS2 mutations in the 35 families studied. We report 15 novel MSH6 and 1 novel PMS2 mutations. The estimated cumulative risk of CRC at age 70 years was 61% (similar in males and females and 65% for endometrial cancer in MSH6 mutation carriers. The risk of developing CRC is different between males and females at age 50 years, which is 34% for males and 21% for females. Conclusion Novel MSH6 and PMS2 mutations are being reported and submitted to the current databases for identified Lynch syndrome mutations. Our data provides additional information to add to the genotype-phenotype spectrum for both MSH6 and PMS2 mutations.
Genschel, Jochen; Kadyrova, Lyudmila Y; Iyer, Ravi R; Dahal, Basanta K; Kadyrov, Farid A; Modrich, Paul
2017-05-09
Eukaryotic MutLα (mammalian MLH1-PMS2 heterodimer; MLH1-PMS1 in yeast) functions in early steps of mismatch repair as a latent endonuclease that requires a mismatch, MutSα/β, and DNA-loaded proliferating cell nuclear antigen (PCNA) for activation. We show here that human PCNA and MutLα interact specifically but weakly in solution to form a complex of approximately 1:1 stoichiometry that depends on PCNA interaction with the C-terminal endonuclease domain of the MutLα PMS2 subunit. Amino acid substitution mutations within a PMS2 C-terminal 721 QRLIAP motif attenuate or abolish human MutLα interaction with PCNA, as well as PCNA-dependent activation of MutLα endonuclease, PCNA- and DNA-dependent activation of MutLα ATPase, and MutLα function in in vitro mismatch repair. Amino acid substitution mutations within the corresponding yeast PMS1 motif ( 723 QKLIIP) reduce or abolish mismatch repair in vivo. Coupling of a weak allele within this motif ( 723 AKLIIP) with an exo1 Δ null mutation, which individually confer only weak mutator phenotypes, inactivates mismatch repair in the yeast cell.
A. Goverde (Anne); M.C.W. Spaander (Manon); D. Nieboer (Daan); A.M.W. van den Ouweland (Ans); W.N.M. Dinjens (Winand); H.J. Dubbink (Erik Jan); C. Tops (Cmj); S.W. Ten Broeke (Sanne W.); M.J. Bruno (Marco); R.M.W. Hofstra (Robert); E.W. Steyerberg (Ewout); A. Wagner (Anja)
2017-01-01
textabstractUntil recently, no prediction models for Lynch syndrome (LS) had been validated for PMS2 mutation carriers. We aimed to evaluate MMRpredict and PREMM5 in a clinical cohort and for PMS2 mutation carriers specifically. In a retrospective, clinic-based cohort we calculated predictions for
Steiner, Meir; Peer, Miki; Palova, Eva; Freeman, Ellen W; Macdougall, Mary; Soares, Claudio N
2011-02-01
The Premenstrual Symptoms Screening Tool was modified for use in adolescents and piloted in 578 girls at three international sites. Nearly one third (29.6%) reported experiencing severe PMS or PMDD, with irritability being the most commonly reported symptom. Rates of menstrual-related pain were high, particularly in those with severe PMS or PMDD. Severe PMS and PMDD present with similar rates and symptoms in adolescents as in adults, and the Premenstrual Symptoms Screening Tool modified for adolescents is a fast, reliable tool to screen for these syndromes in adolescents.
de Barros, Andrea C; Takeda, Agnes A S; Dreyer, Thiago R; Velazquez-Campoy, Adrian; Kobe, Boštjan; Fontes, Marcos R M
2018-03-01
MLH1 and PMS2 proteins form the MutLα heterodimer, which plays a major role in DNA mismatch repair (MMR) in humans. Mutations in MMR-related proteins are associated with cancer, especially with colon cancer. The N-terminal region of MutLα comprises the N-termini of PMS2 and MLH1 and, similarly, the C-terminal region of MutLα is composed by the C-termini of PMS2 and MLH1, and the two are connected by linker region. The nuclear localization sequences (NLSs) necessary for the nuclear transport of the two proteins are found in this linker region. However, the exact NLS sequences have been controversial, with different sequences reported, particularly for MLH1. The individual components are not imported efficiently, presumably due to their C-termini masking their NLSs. In order to gain insights into the nuclear transport of these proteins, we solved the crystal structures of importin-α bound to peptides corresponding to the supposed NLSs of MLH1 and PMS2 and performed isothermal titration calorimetry to study their binding affinities. Both putative MLH1 and PMS2 NLSs can bind to importin-α as monopartite NLSs, which is in agreement with some previous studies. However, MLH1-NLS has the highest affinity measured by a natural NLS peptide, suggesting a major role of MLH1 protein in nuclear import compared to PMS2. Finally, the role of MLH1 and PMS2 in the nuclear transport of the MutLα heterodimer is discussed. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.
Radiation hardness tests of SiPMs for the JLab Hall D Barrel calorimeter
International Nuclear Information System (INIS)
Qiang, Yi; Zorn, Carl; Barbosa, Fernando; Smith, Elton
2013-01-01
We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am–Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed.
SiPMs coated with TPB: coating protocol and characterization for NEXT
International Nuclear Information System (INIS)
Álvarez, V; Agramunt, J; Ball, M; Bayarri, J; Cárcel, S; Cervera, A; Díaz, J; Batallé, M; Borges, F I G; Conde, C A N; Dias, T H V T; Bolink, H; Brine, H; Carmona, J M; Castel, J; Cebrián, S; Dafni, T; Catalá, J M; Esteve, R; Chan, D
2012-01-01
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadiene (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
Dudley, Beth; Brand, Randall E; Thull, Darcy; Bahary, Nathan; Nikiforova, Marina N; Pai, Reetesh K
2015-08-01
Current guidelines on germline mutation testing for patients suspected of having Lynch syndrome are not entirely clear in patients with tumors demonstrating isolated loss of PMS2 immunohistochemical expression. We analyzed the clinical and pathologic features of patients with tumors demonstrating isolated loss of PMS2 expression in an attempt to (1) determine the frequency of germline MLH1 and PMS2 mutations and (2) correlate mismatch-repair protein immunohistochemistry and tumor histology with germline mutation results. A total of 3213 consecutive colorectal carcinomas and 215 consecutive endometrial carcinomas were prospectively analyzed for DNA mismatch-repair protein expression by immunohistochemistry. In total, 32 tumors from 31 patients demonstrated isolated loss of PMS2 immunohistochemical expression, including 16 colorectal carcinomas and 16 endometrial carcinomas. Microsatellite instability (MSI) polymerase chain reaction was performed in 29 tumors from 28 patients with the following results: 28 tumors demonstrated high-level MSI, and 1 tumor demonstrated low-level MSI. Twenty of 31 (65%) patients in the study group had tumors demonstrating histopathology associated with high-level MSI. Seventeen patients underwent germline mutation analysis with the following results: 24% with MLH1 mutations, 35% with PMS2 mutations, 12% with PMS2 variants of undetermined significance, and 29% with no mutations in either MLH1 or PMS2. Three of the 4 patients with MLH1 germline mutations had a mutation that results in decreased stability and quantity of the MLH1 protein that compromises the MLH1-PMS2 protein complex, helping to explain the presence of immunogenic but functionally inactive MLH1 protein within the tumor. The high frequency of MLH1 germline mutations identified in our study has important implications for testing strategies in patients suspected of having Lynch syndrome and indicates that patients with tumors demonstrating isolated loss of PMS2 expression
Electrical characterization and simulation of SiPMs
Energy Technology Data Exchange (ETDEWEB)
Scheuch, Florian, E-mail: scheuch@physik.rwth-aachen.de; Führen, Daniel; Hebbeker, Thomas; Heidemann, Carsten; Merschmeyer, Markus
2015-07-01
Silicon Photomultipliers (SiPMs) are versatile and sensitive photon detectors that experience a fast growing variety of use in particle physics and related fields of application. These photo detectors have a very promising photon detection efficiency and are therefore interesting for very low light flux applications such as scintillation and fluorescence light detection. As a semiconductor device the SiPM's gain and time response strongly depend on the operating temperature and voltage. Thus they have to be understood for a proper use of the SiPM. Therefore, accurate electrical simulations of the SiPM's behavior involving electrical readout and front-end electronics help to improve the design of experimental setups, since several different designs can be tested and simulated with a manageable amount of effort. To perform these simulations, a detailed equivalent circuit of the SiPM has to be used containing a set of well-defined parameters. For this purpose, SPICE simulations of SiPMs and readout electronics have been performed. These simulations utilize an improved SiPM model consisting of resistors, capacitances and inductances. The SiPM parameters for these simulations have been determined by measuring the impedance over a wide frequency range while applying a DC voltage in forward direction and various DC voltages from zero up to the SiPM breakdown voltage in order to determine the behavior under operating conditions. The impedance measurements, the electrical model and the resulting simulations are presented. The impact of different setups and the electrical properties of the SiPM is discussed.
FACT. More than four years of blazar monitoring
Energy Technology Data Exchange (ETDEWEB)
Dorner, Daniela [Universitaet Wuerzburg (Germany); Collaboration: FACT-Collaboration
2016-07-01
Since October 2011, the First G-APD Cherenkov Telescope (FACT) has been collecting more than 5500 hours of physics data. Thanks to the silicon based photosensors (SiPMs, aka G-APDs), observations during bright ambient light like full moon can be carried out without degradation of the sensors. Keeping the gain of the SiPMs stable using an online feedback system, a stable and homogeneous detector performance is achieved. Based on this and an automatic data taking procedure, an unbiased longterm data sample is collected. An automatic quick look analysis provides results shortly after the data are taken allowing to send flare alerts within the same night. The main targets for FACT are the bright TeV blazars Mrk 421 and Mrk 501 which are monitored since January 2012. In addition, several other sources like for example the Crab Nebula, 1ES 1959+650, 1ES 2344+54.1 are observed. In this presentation, the results from more than four years of monitoring are summarized. Several flares from Mrk 501 and Mrk 421 are discussed in the multi-wavelength (MWL) context. Mrk 501 underwent major outbursts in June 2012 and June 2014 during the yearly MWL campaigns. Mrk 421 showed a bright flare in April 2013 where also MWL observations are available. 1ES 1959+650 showed enhanced flux in autumn 2015. Results from these observations are discussed.
Deficient Pms2, ERCC1, Ku86, CcOI in field defects during progression to colon cancer.
Nguyen, Huy; Loustaunau, Cristy; Facista, Alexander; Ramsey, Lois; Hassounah, Nadia; Taylor, Hilary; Krouse, Robert; Payne, Claire M; Tsikitis, V Liana; Goldschmid, Steve; Banerjee, Bhaskar; Perini, Rafael F; Bernstein, Carol
2010-07-28
In carcinogenesis, the "field defect" is recognized clinically because of the high propensity of survivors of certain cancers to develop other malignancies of the same tissue type, often in a nearby location. Such field defects have been indicated in colon cancer. The molecular abnormalities that are responsible for a field defect in the colon should be detectable at high frequency in the histologically normal tissue surrounding a colonic adenocarcinoma or surrounding an adenoma with advanced neoplasia (well on the way to a colon cancer), but at low frequency in the colonic mucosa from patients without colonic neoplasia. Using immunohistochemistry, entire crypts within 10 cm on each side of colonic adenocarcinomas or advanced colonic neoplasias were found to be frequently reduced or absent in expression for two DNA repair proteins, Pms2 and/or ERCC1. Pms2 is a dual role protein, active in DNA mismatch repair as well as needed in apoptosis of cells with excess DNA damage. ERCC1 is active in DNA nucleotide excision repair. The reduced or absent expression of both ERCC1 and Pms2 would create cells with both increased ability to survive (apoptosis resistance) and increased level of mutability. The reduced or absent expression of both ERCC1 and Pms2 is likely an early step in progression to colon cancer. DNA repair gene Ku86 (active in DNA non-homologous end joining) and Cytochrome c Oxidase Subunit I (involved in apoptosis) had each been reported to be decreased in expression in mucosal areas close to colon cancers. However, immunohistochemical evaluation of their levels of expression showed only low to modest frequencies of crypts to be deficient in their expression in a field defect surrounding colon cancer or surrounding advanced colonic neoplasia. We show, here, our method of evaluation of crypts for expression of ERCC1, Pms2, Ku86 and CcOI. We show that frequency of entire crypts deficient for Pms2 and ERCC1 is often as great as 70% to 95% in 20 cm long areas
Studies on surface-mounted SiPMs in 2015 testbeam of a highly granular hadron calorimeter
Energy Technology Data Exchange (ETDEWEB)
Krause, Sascha [Institut fuer Physik, Johannes Gutenberg-Universitaet Mainz, Mainz (Germany); Collaboration: CALICE-D-Collaboration
2016-07-01
To achieve excellent jet energy resolution, a highly granular hadronic calorimeter is being developed within the CALICE collaboration. Therefore, about 8 million detector units consisting of scintillator tiles and silicon photomultipliers (SiPMs) will be installed in the final HCAL design. The usage of surface-mounted (SMD) SiPMs allows an automated mass assembly. During CERN SPS testbeam 2015, data for a prototype consisting of up to 11 layers of HCAL base units (HBU) was collected using electron, muon and pion beams. One of the layers was equipped with the first SMD HBU. Results and performance, especially of the SMD HBU are presented.
Ehrenstein, Michael R.; Rada, Cristina; Jones, Anne-Marie; Milstein, César; Neuberger, Michael S.
2001-01-01
Isotype switching involves a region-specific, nonhomologous recombinational deletion that has been suggested to occur by nonhomologous joining of broken DNA ends. Here, we find increased donor/acceptor homology at switch junctions from PMS2-deficient mice and propose that class switching can occur by microhomology-mediated end-joining. Interestingly, although isotype switching and somatic hypermutation show many parallels, we confirm that PMS2 deficiency has no major effect on the pattern of nucleotide substitutions generated during somatic hypermutation. This finding is in contrast to MSH2 deficiency. With MSH2, the altered pattern of switch recombination and hypermutation suggests parallels in the mechanics of the two processes, whereas the fact that PMS2 deficiency affects only switch recombination may reflect differences in the pathways of break resolution. PMID:11717399
Diagnosis and analysis for PMS model implementation in a footwear industry
Directory of Open Access Journals (Sweden)
Marcia Athayde Moreira
2017-08-01
Full Text Available One of the options that the literature suggests assisting challenges in performance evaluation comes from studies of management control systems, which have been an important mechanism to assist in business performance evaluation. Given this fact, this study aims to analyze what are the difficulties and the possible benefits that the implementation of performance management systems - PMS model developed by Ferreira and Otley (2009 could help an evaluation of strategic and operational performance. So, we did a case study in a large Brazilian shoe industry. The results indicate that the main difficulties were: identification of key success factors; identification of key performance measures; creation of a reward or sanction policy for the results. As for the expected benefits, the results showed that the implementation would promote: greater integration between strategy and operations; creating more consistent business strategies; correct measurement of performance; and better fit with the objectives outlined.
Liu, Yangxian; Wang, Yan; Wang, Qian; Pan, Jianfeng; Zhang, Jun
2018-01-01
Simultaneous removal process of SO 2 and NO from flue gas using vacuum ultraviolet light (VUV)/heat/peroxymonosulfate (PMS) in a VUV spraying reactor was proposed. The key influencing factors, active species, reaction products and mechanism of SO 2 and NO simultaneous removal were investigated. The results show that vacuum ultraviolet light (185 nm) achieves the highest NO removal efficiency and yield of and under the same test conditions. NO removal is enhanced at higher PMS concentration, light intensity and oxygen concentration, and is inhibited at higher NO concentration, SO 2 concentration and solution pH. Solution temperature has a double impact on NO removal. CO 2 concentration has no obvious effect on NO removal. and produced from VUV-activation of PMS play a leading role in NO removal. O 3 and ·O produced from VUV-activation of O 2 also play an important role in NO removal. SO 2 achieves complete removal under all experimental conditions due to its very high solubility in water and good reactivity. The highest simultaneous removal efficiency of SO 2 and NO reaches 100% and 91.3%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Guo, Liyan; Xia, Changliang; Wang, Huimin; Wang, Zhiqiang; Shi, Tingna
2018-05-01
As is well known, the armature current will be ahead of the back electromotive force (back-EMF) under load condition of the interior permanent magnet (PM) machine. This kind of advanced armature current will produce a demagnetizing field, which may make irreversible demagnetization appeared in PMs easily. To estimate the working points of PMs more accurately and take demagnetization under consideration in the early design stage of a machine, an improved equivalent magnetic network model is established in this paper. Each PM under each magnetic pole is segmented, and the networks in the rotor pole shoe are refined, which makes a more precise model of the flux path in the rotor pole shoe possible. The working point of each PM under each magnetic pole can be calculated accurately by the established improved equivalent magnetic network model. Meanwhile, the calculated results are compared with those calculated by FEM. And the effects of d-axis component and q-axis component of armature current, air-gap length and flux barrier size on working points of PMs are analyzed by the improved equivalent magnetic network model.
Inactivation of DNA mismatch repair by variants of uncertain significance in the PMS2 gene.
Drost, Mark; Koppejan, Hester; de Wind, Niels
2013-11-01
Lynch syndrome (LS) is a common cancer predisposition caused by an inactivating mutation in one of four DNA mismatch repair (MMR) genes. Frequently a variant of uncertain significance (VUS), rather than an obviously pathogenic mutation, is identified in one of these genes. The inability to define pathogenicity of such variants precludes targeted healthcare. Here, we have modified a cell-free assay to test VUS in the MMR gene PMS2 for functional activity. We have analyzed nearly all VUS in PMS2 found thus far and describe loss of MMR activity for five, suggesting the applicability of the assay for diagnosis of LS. © 2013 WILEY PERIODICALS, INC.
Wang, Zuoyun; Sun, Yihua; Gao, Bin; Lu, Yi; Fang, Rong; Gao, Yijun; Xiao, Tian; Liu, Xin-Yuan; Pao, William; Zhao, Yun; Chen, Haiquan; Ji, Hongbin
2014-01-01
Germline mutations are responsible for familial cancer syndromes which account for approximately 5-10% of all types of cancers. These mutations mainly occur at tumor suppressor genes or genome stability genes, such as DNA repair genes. Here we have identified a cancer predisposition family, in which eight members were inflicted with a wide spectrum of cancer including one diagnosed with lung cancer at 22years old. Sequencing analysis of tumor samples as well as histologically normal specimens identified two germline mutations co-existing in the familial cancer syndrome, the mutation of tumor suppressor gene P53 V157D and mismatch repair gene PMS2 R20Q. We further demonstrate that P53 V157D and/or PMS2 R20Q mutant promotes lung cancer cell proliferation. These two mutants are capable of promoting colony formation in soft agar as well as tumor formation in transgenic drosophila system. Collectively, these data have uncovered the important role of co-existing germline P53 and PMS2 mutations in the familial cancer syndrome development. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A Framework of Performance Measurement System for Manufacturing Company
Directory of Open Access Journals (Sweden)
Dermawan Wibisono
2012-04-01
Full Text Available In the current dynamic environment, measuring a company’s performance becomes exceedingly complex since Performance Measurements Systems (PMS not only measure a company’s performance but also reflect their organizational culture and philosophy. Designing and implementing PMS is an integral part of management control systems. However, traditional PMS are criticized for being obsolete, irrelevant to managerial decisionmaking, unrelated to strategic objectives and detrimental to organizational improvements. Given the shortcomings of traditional PMS, there is need for a new framework that canlead to the design of a PMS that balances short-term and long-term measures, internal and external measures, and financial and operational measures. This paper presents issuesassociated with the needs of a dynamic PMS, observe past research achievements in PMS and review past PMS frameworks that have been introduced. The paper then proposes animproved methodology for the design of a realistic PMS and its effective implementation in a manufacturing environment with case for Indonesia’s company.
A Framework of Performance Measurement System for Manufacturing Company
Directory of Open Access Journals (Sweden)
Dermawan Wibisono
2011-10-01
Full Text Available In the current dynamic environment, measuring a company’s performance becomes exceedingly complex since Performance Measurements Systems (PMS not only measure a company’s performance but also reflect their organizational culture and philosophy. Designing and implementing PMS is an integral part of management control systems. However, traditional PMS are criticized for being obsolete, irrelevant to managerial decision making, unrelated to strategic objectives and detrimental to organizational improvements. Given the shortcomings of traditional PMS, there is need for a new framework that can lead to the design of a PMS that balances short-term and long-term measures, internal and external measures, and financial and operational measures. This paper presents issues associated with the needs of a dynamic PMS, observe past research achievements in PMS and review past PMS frameworks that have been introduced. The paper then proposes an improved methodology for the design of a realistic PMS and its effective implementation in a manufacturing environment with case for Indonesia’s company.
Hall, Geoffrey; Clarkson, Adele; Shi, Amanda; Langford, Eileen; Leung, Helen; Eckstein, Robert P; Gill, Anthony J
2010-01-01
Currently, testing for mismatch repair deficiency in colorectal cancers is initiated by performing immunohistochemistry with four antibodies (MLH1, PMS2, MSH2 and MSH6). If any one of these stains is negative the tumour is considered microsatellite unstable and, if clinical circumstances warrant it, the patient is offered genetic testing for Lynch's syndrome. Due to the binding properties of the mismatch repair heterodimer complexes, gene mutation and loss of MLH1 and MSH2 invariably result in the degradation of PMS2 and MSH6, respectively, but the converse is not true. We propose that staining for PMS2 and MSH6 alone will be sufficient to detect all cases of mismatch repair deficiency and should replace routine screening with all four antibodies. The electronic database of the department of Anatomical Pathology, Royal North Shore Hospital, Sydney, Australia, was searched for all colorectal carcinomas on which a four panel immunohistochemical microsatellite instability screen was performed. An audit of the slides for concordant loss of MLH1-PMS2 and MSH2-MSH6 was then undertaken. Unusual or discordant cases were reviewed and, in some cases, re-stained to confirm the staining pattern. Of 344 cases of colorectal cancer which underwent four antibody immunohistochemistry, 104 displayed loss of at least one mismatch repair protein. Of these, 100 showed concordant mismatch repair loss (i.e., loss of MLH1 and PMS2 or loss of MSH2 and MSH6). The four discordant cases comprised two single negative cases (1 MSH6 negative/MSH2 positive case, 1 PMS2 negative/MLH1 positive) and two triple negative (both MLH1/PMS2/MSH6 negative). The microsatellite instability (MSI) group showed a relatively high median age (69.3 years) due to the departmental policy of testing all cases with possible MSI morphology regardless of age. The sensitivity and specificity of a two panel test comprised of PMS2 and MSH6, compared to a four panel test, is 100%. No false negatives or positives were
Klift, H.M. van der; Mensenkamp, A.R.; Drost, M.; Bik, E.C.; Vos, Y.J.; Gille, H.J.; Redeker, B.E.; Tiersma, Y.; Zonneveld, J.B.; Garcia, E.G.; Letteboer, T.G.; Olderode-Berends, M.J.; Hest, L.P. van; Os, T.A. van; Verhoef, S.; Wagner, A.; Asperen, C.J. van; Broeke, S.W. ten; Hes, F.J.; Wind, N. de; Nielsen, M.; Devilee, P.; Ligtenberg, M.J.L.; Wijnen, J.T.; Tops, C.M.
2016-01-01
Monoallelic PMS2 germline mutations cause 5%-15% of Lynch syndrome, a midlife cancer predisposition, whereas biallelic PMS2 mutations cause approximately 60% of constitutional mismatch repair deficiency (CMMRD), a rare childhood cancer syndrome. Recently improved DNA- and RNA-based strategies are
van der Klift, Heleen M.; Mensenkamp, Arjen R.; Drost, Mark; Bik, Elsa C.; Vos, Yvonne J.; Gille, Hans J. J. P.; Redeker, Bert E. J. W.; Tiersma, Yvonne; Zonneveld, Jose B. M.; Garcia, Encarna Gomez; Letteboer, Tom G. W.; Olderode-Berends, Maran J. W.; van Hest, Liselotte P.; van Os, Theo A.; Verhoef, Senno; Wagner, Anja; van Asperen, Christi J.; ten Broeke, Sanne W.; Hes, Frederik J.; de Wind, Niels; Nielsen, Maartje; Devilee, Peter; Ligtenberg, Marjolijn J. L.; Wijnen, Juul T.; Tops, Carli M. J.
Monoallelic PMS2 germline mutations cause 5%-15% of Lynch syndrome, a midlife cancer predisposition, whereas biallelic PMS2 mutations cause approximately 60% of constitutional mismatch repair deficiency (CMMRD), a rare childhood cancer syndrome. Recently improved DNA- and RNA-based strategies are
Will, Olivia; Carvajal-Carmona, Luis G; Gorman, Patricia; Howarth, Kimberley M; Jones, Angela M; Polanco-Echeverry, Guadalupe M; Chinaleong, Jo-Anne; Günther, Thomas; Silver, Andrew; Clark, Susan K; Tomlinson, Ian
2007-02-01
We report a patient of Indian descent with parental consanguinity, who developed 10 carcinomas and 35 adenomatous polyps at age 23 and duodenal adenocarcinoma at age 25. He also had dysmorphic features, mental retardation, and café-au-lait spots but no brain tumor. We aimed to establish his molecular diagnosis. Germ-line screening for APC and MYH/MUTYH mutations was normal as was immunohistochemistry for MLH1 and MSH2 proteins. Investigation by array-comparative genomic hybridization revealed deletion of a small region on chromosome 7. Using polymerase chain reaction, this region was refined to a 400-kilobase deletion, which included exons 9-15 of the PMS2 gene, and all coding regions of oncomodulin, TRIAD3, and FSCN1. The deletion was confirmed as homozygous, and both parents were carriers. Immunohistochemistry showed absent PMS2 expression in all tumors and normal tissue. Most tumors showed microsatellite instability, more marked at dinucleotide than mononucleotide repeats. The tumors harbored no somatic mutations in APC, BRAF, AXIN2, or beta-catenin, but KRAS2 and TGFBR2 mutations were found. Our patient represents a novel phenotype for homozygous PMS2 mutation and perhaps the most severe colorectal cancer phenotype-in terms of numbers of malignancies at an early age-described to date. PMS2 mutations-and perhaps other homozygous mismatch repair mutations-should be considered in any patient presenting with multiple gastrointestinal tumors, since our patient could not be distinguished clinically from cases with attenuated familial adenomatous polyposis or MUTYH-associated polyposis.
A frame-shift mutation of PMS2 is a widespread cause of Lynch syndrome
DEFF Research Database (Denmark)
Clendenning, Mark; Senter, Leigha; Hampel, Heather
2008-01-01
BACKGROUND: When compared to the other mismatch repair genes involved in Lynch syndrome, the identification of mutations within PMS2 has been limited (Lynch syndrome cases...... on immunohistochemical analysis. RESULTS: We have identified a frequently occurring frame-shift mutation (c.736_741del6ins11) in 12 ostensibly unrelated Lynch syndrome patients (20% of patients we have identified with a deleterious mutation in PMS2, n=61). These individuals all display the rare allele (population...... and Swedish ancestry. We estimate that there are >10,000 carriers of this mutation in the United States alone. The identification of both the mutation and the common haplotype in one Swedish control sample (n = 225), along with evidence that Lynch syndrome associated cancers are rarer than expected...
Performance management system enhancement and maintenance
Cleaver, T. G.; Ahour, R.; Johnson, B. R.
1984-01-01
The research described in this report concludes a two-year effort to develop a Performance Management System (PMS) for the NCC computers. PMS provides semi-automated monthly reports to NASA and contractor management on the status and performance of the NCC computers in the TDRSS program. Throughout 1984, PMS was tested, debugged, extended, and enhanced. Regular PMS monthly reports were produced and distributed. PMS continues to operate at the NCC under control of Bendix Corp. personnel.
Jeske, Y W A; So, A; Kelemen, L; Sukor, N; Willys, C; Bulmer, B; Gordon, R D; Duffy, D; Stowasser, M
2008-04-01
1. There are two types of familial hyperaldosteronism (FH): FH-I and FH-II. FH-I is caused by a hybrid CYP11B1/CYP11B2 gene mutation. The genetic cause of FH-II, which is more common, is unknown. Adrenal hyperplasia and adenomas are features. We previously reported linkage of FH-II to a approximately 5 Mb region on chromosome 7p22. We subsequently reported finding no causative mutations in the retinoblastoma-associated Kruppel-associated box gene (RBaK), a candidate at 7p22 involved in tumorigenesis and cell cycle control. 2. In the current study we investigated RBaK regulatory regions and two other candidate genes: postmeiotic segregation increased 2 (PMS2, involved in DNA mismatch repair and tumour predisposition) and guanine nucleotide-binding protein alpha-12 (GNA12, a transforming oncogene). 3. The GNA12 and PMS2 genes were examined in two affected (A1, A2) and two unaffected (U1, U2) subjects from a large 7p22-linked FH-II family (family 1). No mutations were found. 4. The RBaK and PMS2 distal promoters were sequenced to -2150 bp from the transcription start site for RBaK and-2800 bp for PMS2. Five unreported single nucleotide polymorphisms (SNPs) were found in subjects A1, A2 but not in U1 or U2; A(-2031 bp)T, T(-2030 bp)G, G(-834 bp)C, C(-821 bp)G in RBaK and A(-876 bp)G in PMS2. Additional affected and unaffected subjects from family 1 and from two other 7p22-linked FH-II families and 58 unrelated normotensive control subjects were genotyped for these SNPs. 5. The five novel SNPs were found to be present in a significant proportion of normotensive controls. The four RBaK promoter SNPs were found to be in linkage disequilibrium in the normal population. The RBaK promoter (-)2031T/2030G/834C/821T allele was found to be in linkage disequilibrium with the causative mutation in FH-II family 1, but not in families 2 and 3. The PMS2 promoter (-)876G allele was also found to be linked to affected phenotypes in family 1. 6. The RBaK and PMS2 promoter SNPs alter the
Oxidation of Refractory Benzothiazoles with PMS/CuFe2O4: Kinetics and Transformation Intermediates
Zhang, Tao; Chen, Yin; Leiknes, TorOve
2016-01-01
Benzothiazole (BTH) and its derivatives, 2-(methylthio)bezothiazole (MTBT), 2-benzothiazolsulfonate (BTSA) and 2-hydroxybenzothiazole (OHBT), are refractory pollutants ubiquitously existing in urban runoff at relatively high concentrations. Here, we report their oxidation by CuFe2O4-activated peroxomonosulfate (PMS/CuFe2O4), focusing on kinetics and transformation intermediates. These benzothiazoles can be efficiently degraded by this oxidation process which is confirmed to generate mainly sulfate radicals (with negligible hydroxyl-radical formation) under slightly acidic to neutral pH conditions. The molar exposure ratio of sulfate radical to residual PMS (i.e. Rct) of this process is a constant which is related to reaction condition and can be easily determined. Reaction rate constants of these benzothiazoles towards sulfate radical are (3.3 ± 0.3) × 109, (1.4 ± 0.3) × 109, (1.5 ± 0.1) × 109 and (4.7 ± 0.5) × 109 M-1s-1, respectively (pH 7 and 20 oC). Based on Rct and these rate constants, their degradation in the presence of organic matter can be well predicted. A number of transformation products were detected and tentatively identified using triple-quadruple/linear ion trap MS/MS and high-resolution MS. It appears that sulfate radicals attack BTH, MTBT and BTSA on their benzo ring via electron transfer, generating multiple hydroxylated intermediates which are reactive towards common oxidants. For OHBT oxidation, it prefers to break down the thiazole ring. Due to competitions of the transformation intermediates, a minimum PMS/pollutant molar ratio of 10-20 is required for effective degradation. The flexible PMS/CuFe2O4 could be a useful process to remove the benzothiazoles from low DOC waters like urban runoff or polluted groundwater.
Oxidation of Refractory Benzothiazoles with PMS/CuFe2O4: Kinetics and Transformation Intermediates
Zhang, Tao
2016-05-04
Benzothiazole (BTH) and its derivatives, 2-(methylthio)bezothiazole (MTBT), 2-benzothiazolsulfonate (BTSA) and 2-hydroxybenzothiazole (OHBT), are refractory pollutants ubiquitously existing in urban runoff at relatively high concentrations. Here, we report their oxidation by CuFe2O4-activated peroxomonosulfate (PMS/CuFe2O4), focusing on kinetics and transformation intermediates. These benzothiazoles can be efficiently degraded by this oxidation process which is confirmed to generate mainly sulfate radicals (with negligible hydroxyl-radical formation) under slightly acidic to neutral pH conditions. The molar exposure ratio of sulfate radical to residual PMS (i.e. Rct) of this process is a constant which is related to reaction condition and can be easily determined. Reaction rate constants of these benzothiazoles towards sulfate radical are (3.3 ± 0.3) × 109, (1.4 ± 0.3) × 109, (1.5 ± 0.1) × 109 and (4.7 ± 0.5) × 109 M-1s-1, respectively (pH 7 and 20 oC). Based on Rct and these rate constants, their degradation in the presence of organic matter can be well predicted. A number of transformation products were detected and tentatively identified using triple-quadruple/linear ion trap MS/MS and high-resolution MS. It appears that sulfate radicals attack BTH, MTBT and BTSA on their benzo ring via electron transfer, generating multiple hydroxylated intermediates which are reactive towards common oxidants. For OHBT oxidation, it prefers to break down the thiazole ring. Due to competitions of the transformation intermediates, a minimum PMS/pollutant molar ratio of 10-20 is required for effective degradation. The flexible PMS/CuFe2O4 could be a useful process to remove the benzothiazoles from low DOC waters like urban runoff or polluted groundwater.
A System Based on the Internet of Things for Real-Time Particle Monitoring in Buildings
Directory of Open Access Journals (Sweden)
Gonçalo Marques
2018-04-01
Full Text Available Occupational health can be strongly influenced by the indoor environment as people spend 90% of their time indoors. Although indoor air quality (IAQ is not typically monitored, IAQ parameters could be in many instances very different from those defined as healthy values. Particulate matter (PM, a complex mixture of solid and liquid particles of organic and inorganic substances suspended in the air, is considered the pollutant that affects more people. The most health-damaging particles are the ≤PM10 (diameter of 10 microns or less, which can penetrate and lodge deep inside the lungs, contributing to the risk of developing cardiovascular and respiratory diseases, as well as of lung cancer. This paper presents an Internet of Things (IoT system for real-time PM monitoring named iDust. This system is based on a WEMOS D1 mini microcontroller and a PMS5003 PM sensor that incorporates scattering principle to measure the value of particles suspended in the air (PM10, PM2.5, and PM1.0. Through a Web dashboard for data visualization and remote notifications, the building manager can plan interventions for enhanced IAQ and ambient assisted living (AAL. Compared to other solutions the iDust is based on open-source technologies, providing a total Wi-Fi system, with several advantages such as its modularity, scalability, low cost, and easy installation. The results obtained are very promising, representing a meaningful tool on the contribution to IAQ and occupational health.
A System Based on the Internet of Things for Real-Time Particle Monitoring in Buildings.
Marques, Gonçalo; Roque Ferreira, Cristina; Pitarma, Rui
2018-04-21
Occupational health can be strongly influenced by the indoor environment as people spend 90% of their time indoors. Although indoor air quality (IAQ) is not typically monitored, IAQ parameters could be in many instances very different from those defined as healthy values. Particulate matter (PM), a complex mixture of solid and liquid particles of organic and inorganic substances suspended in the air, is considered the pollutant that affects more people. The most health-damaging particles are the ≤PM 10 (diameter of 10 microns or less), which can penetrate and lodge deep inside the lungs, contributing to the risk of developing cardiovascular and respiratory diseases, as well as of lung cancer. This paper presents an Internet of Things (IoT) system for real-time PM monitoring named iDust. This system is based on a WEMOS D1 mini microcontroller and a PMS5003 PM sensor that incorporates scattering principle to measure the value of particles suspended in the air (PM 10 , PM 2.5 , and PM 1.0 ). Through a Web dashboard for data visualization and remote notifications, the building manager can plan interventions for enhanced IAQ and ambient assisted living (AAL). Compared to other solutions the iDust is based on open-source technologies, providing a total Wi-Fi system, with several advantages such as its modularity, scalability, low cost, and easy installation. The results obtained are very promising, representing a meaningful tool on the contribution to IAQ and occupational health.
Cheyuo, Cletus; Radwan, Walid; Ahn, Janice; Gyure, Kymberly; Qaiser, Rabia; Tomboc, Patrick
2017-10-01
Constitutional mismatch repair deficiency syndrome is a cancer predisposition syndrome caused by autosomal recessive biallelic (homozygous) germline mutations in the mismatch repair genes (MLH1, MSH2, MSH6, and PMS2). The clinical spectrum includes neoplastic and non-neoplastic manifestations. We present the case of a 7-year-old boy who presented with T-lymphoblastic lymphoma and glioblastoma, together with non-neoplastic manifestations including corpus callosum agenesis, arachnoid cyst, developmental venous anomaly, and hydrocephalus. Gene mutation analysis revealed pathogenic biallelic mutations of PMS2 and heterozygous DICER1 variant predicted to be pathogenic. This report is the first to allude to a possible interaction of the mismatch repair system with DICER1 to cause corpus callosum agenesis.
van der Klift, Heleen M; Mensenkamp, Arjen R; Drost, Mark; Bik, Elsa C; Vos, Yvonne J; Gille, Hans J J P; Redeker, Bert E J W; Tiersma, Yvonne; Zonneveld, José B M; García, Encarna Gómez; Letteboer, Tom G W; Olderode-Berends, Maran J W; van Hest, Liselotte P; van Os, Theo A; Verhoef, Senno; Wagner, Anja; van Asperen, Christi J; Ten Broeke, Sanne W; Hes, Frederik J; de Wind, Niels; Nielsen, Maartje; Devilee, Peter; Ligtenberg, Marjolijn J L; Wijnen, Juul T; Tops, Carli M J
2016-01-01
Monoallelic PMS2 germline mutations cause 5-15% of Lynch syndrome, a midlife cancer predisposition, whereas biallelic PMS2 mutations cause approximately 60% of constitutional MMR deficiency (CMMRD), a rare childhood cancer syndrome. Recently improved DNA and RNA-based strategies are applied to
Mork, Maureen E; Borras, Ester; Taggart, Melissa W; Cuddy, Amanda; Bannon, Sarah A; You, Y Nancy; Lynch, Patrick M; Ramirez, Pedro T; Rodriguez-Bigas, Miguel A; Vilar, Eduardo
2016-10-01
Constitutional mismatch repair deficiency syndrome (CMMRD) is a rare autosomal recessive predisposition to colorectal polyposis and other malignancies, often childhood-onset, that is caused by biallelic inheritance of mutations in the same mismatch repair gene. Here, we describe a patient with a clinical diagnosis of CMMRD based on colorectal polyposis and young-onset endometrial cancer who was identified to have two alterations in trans in PMS2: one known pathogenic mutation (c.1831insA; p.Ile611Asnfs*2) and one novel variant of uncertain significance (c.505C>G; p.Arg169Glu), a missense alteration. We describe the clinical and molecular features in the patient harboring this novel alteration c.505C>G, who meets clinical criteria for CMMRD and exhibits molecular evidence supporting a diagnosis of CMMRD. Although experimental validation is needed to confirm its pathogenicity, PMS2 c.505C>G likely has functional consequences that contributes to our patient's phenotype based on the patient's clinical presentation, tumor studies, and bioinformatics analysis.
Leenen, C H M; Geurts-Giele, W R R; Dubbink, H J; Reddingius, R; van den Ouweland, A M; Tops, C M J; van de Klift, H M; Kuipers, E J; van Leerdam, M E; Dinjens, W N M; Wagner, A
2011-12-01
Heterozygous germline mutations in the mismatch repair (MMR) genes MLH1, MSH2, MSH6 and PMS2 cause Lynch syndrome. Biallelic mutations in the MMR genes are associated with a childhood cancer syndrome [constitutional mismatch repair deficiency (CMMR-D)]. This is predominantly characterized by hematological malignancies and tumors of the bowel and brain, often associated with signs of neurofibromatosis type 1 (NF1). Diagnostic strategies for selection of patients for MMR gene analysis include analysis of microsatellite instability (MSI) and immunohistochemical (IHC) analysis of MMR proteins in tumor tissue. We report the clinical characterization and molecular analyses of tumor specimens from a family with biallelic PMS2 germline mutations. This illustrates the pitfalls of present molecular screening strategies. Tumor tissues of five family members were analyzed for MSI and IHC. MSI was observed in only one of the analyzed tissues. However, IHC analysis of brain tumor tissue of the index patient and his sister showed absence of PMS2 expression, and germline mutation analyses showed biallelic mutations in PMS2: p.Ser46IIe and p.Pro246fs. The same heterozygous mutations were confirmed in the father and mother, respectively. These data support the conclusion that in case of a clinical phenotype of CMMR-D, it is advisable to routinely combine MSI analysis with IHC analysis for the expression of MMR proteins. With inconclusive or conflicting results, germline mutation analysis of the MMR genes should be considered after thorough counselling of the patients and/or their relatives. © 2011 John Wiley & Sons A/S.
Setup and Calibration of SLAC's Peripheral Monitoring Stations
Energy Technology Data Exchange (ETDEWEB)
Cooper, C.
2004-09-03
The goals of this project were to troubleshoot, repair, calibrate, and establish documentation regarding SLAC's (Stanford Linear Accelerator Center's) PMS (Peripheral Monitoring Station) system. The PMS system consists of seven PMSs that continuously monitor skyshine (neutron and photon) radiation levels in SLAC's environment. Each PMS consists of a boron trifluoride (BF{sub 3}) neutron detector (model RS-P1-0802-104 or NW-G-20-12) and a Geiger Moeller (GM) gamma ray detector (model TGM N107 or LND 719) together with their respective electronics. Electronics for each detector are housed in Nuclear Instrument Modules (NIMs) and are plugged into a NIM bin in the station. All communication lines from the stations to the Main Control Center (MCC) were tested prior to troubleshooting. To test communication with MCC, a pulse generator (Systron Donner model 100C) was connected to each channel in the PMS and data at MCC was checked for consistency. If MCC displayed no data, the communication cables to MCC or the CAMAC (Computer Automated Measurement and Control) crates were in need of repair. If MCC did display data, then it was known that the communication lines were intact. All electronics from each station were brought into the lab for troubleshooting. Troubleshooting usually consisted of connecting an oscilloscope or scaler (Ortec model 871 or 775) at different points in the circuit of each detector to record simulated pulses produced by a pulse generator; the input and output pulses were compared to establish the location of any problems in the circuit. Once any problems were isolated, repairs were done accordingly. The detectors and electronics were then calibrated in the field using radioactive sources. Calibration is a process that determines the response of the detector. Detector response is defined as the ratio of the number of counts per minute interpreted by the detector to the amount of dose equivalent rate (in mrem per hour, either calculated
Pai, Rish K; Plesec, Thomas P; Abdul-Karim, Fadi W; Yang, Bin; Marquard, Jessica; Shadrach, Bonnie; Roma, Andres R
2015-07-01
Given that endometrial cancer (EC) is often the sentinel cancer for female Lynch syndrome patients, we have successfully implemented universal screening of ECs and have previously shown that this is the preferred method to identify these patients. However, during the course of universal screening of EC, we encountered 6 cases with an unusual pattern of mismatch-repair protein immunohistochemistry that has not been previously described in this setting. In these 6 cases, there was an abrupt loss of MLH1 and PMS2 expression in a portion of the tumor. In 3 cases, marked histologic differences were identified between the areas of the tumor with retained expression and areas with loss of expression. In 2 cases, the areas with loss of expression were of higher grade (1 demonstrated solid growth and the other demonstrated increased nuclear atypia with diffuse p53 expression). In 4 tumors, histologic features associated with microsatellite instability (MSI) were present, including increased intraepithelial lymphocytes. The areas with loss of and retained MLH1/PMS2 expression were separately microdissected and assessed for MSI and MLH1 promoter methylation. The areas with loss of MLH1 and PMS2 more commonly demonstrated MSI compared with the areas with intact expression (83% vs. 33%). MLH1 promoter methylation analysis demonstrated heterogenous hypermethylation, as all areas with loss of MLH1/PMS2 expression had more extensive methylation of MLH1 compared with those areas with retained expression. In summary, we describe the histologic and molecular features of 6 cases of EC with abrupt loss of MLH1 and PMS2 expression and demonstrate that heterogenous methylation of the MLH1 promoter results in this distinct and unusual pattern of immunohistochemical expression.
Directory of Open Access Journals (Sweden)
G. A. Raskin
2015-01-01
Full Text Available Microsatellite instability is associated with dysfunction of the MSH2, MLH1, PMS2 and MSH6 genes, which participate in the repair of unpaired nucleotides of DNA. It is known that microsatellite instability is an independent prognostic factor in determining the differentiation grade of colon cancer. The use of immunohistochemistry to study the repair system of unpaired nucleotides has its own characteristics and limitations. Materials and methods. The study included 39 patients with colon adenocarcinoma. Moderately-differentiated colon adenocarcinoma was the most common histological type (72 %. There were 8 % of well-differentiated and 12 % poorly-differentiated carcinomas. Immunohistochemical analysis of SH2, MSH6, PMS2 and MLH1 proteins was done according to the standard protocol. Results. Out of 39 cases, 6 (15 % had loss of expression of at least one of the studied proteins. Out of these 6 cases with indirect signs of MSI-H, 3 were poorlydifferentiated, 1 was mucinous and 2 were moderately differentiated adenocarcinomas. Conclusion. Thus, immunohistochemical analysis of DNA repair genes can be used to determine the histological differentiation of colon adenocarcinoma.
Detector block based on arrays of 144 SiPMs and monolithic scintillators: A performance study
International Nuclear Information System (INIS)
González, A.J.; Conde, P.; Iborra, A.; Aguilar, A.; Bellido, P.; García-Olcina, R.; Hernández, L.; Moliner, L.; Rigla, J.P.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Seimetz, M.; Soriano, A.; Torres, J.; Vidal, L.F.; Benlloch, J.M.
2015-01-01
We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12×12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured
International Nuclear Information System (INIS)
Hauck, P.
1978-01-01
Infantile female rats were made pseudogravid with PMS-HCG (according to Karg). Two bioassays were employed to investigate the effects of HCG on the ovaries; the HCG was injected subactaneously in the back of the animals in varying doses and at various intervals after the initial PMS administration. As specific parameters, oestrogen and progesterone levels in serum and ovary homogenate were determined radioimmunologically. The first animal experiment showed that the ovaries of pseudogravid animals had reached maximum sensitivity for corpus luteum production after HCG administration between 50 and 70 hours after PMS administration. In the second animal experiment with repeated HCG stimulus in the luteal phase, it was found that the corpus luteum of the rat ovary is apparently unable to synthesize oestrogens. In contrast, progesteron synthesis received maximum stimulation already with the lowest dose administered (3 IE HCG). The experiments clearly showed a dependence on HCG dose and the time which the test substance is allowed to take effect. (orig./AJ) 891 AJ/orig.- 892 KN [de
Post Launch Monitoring of food products : what can be learned from pharmacovigilance
van Puijenbroek, E P; Hepburn, P A; Herd, T M; van Grootheest, A C
Post Launch Monitoring (PLM) is one of the new approaches that are used in assessing the safety of novel foods or ingredients. It shares a close resemblance with procedures applied in the field of medicines, where Post Marketing Surveillance (PMS) has been carried out since the beginning of the
Application of large area SiPMs for the readout of a plastic scintillator based timing detector
Betancourt, C.; Blondel, A.; Brundler, R.; Dätwyler, A.; Favre, Y.; Gascon, D.; Gomez, S.; Korzenev, A.; Mermod, P.; Noah, E.; Serra, N.; Sgalaberna, D.; Storaci, B.
2017-11-01
In this study an array of eight 6 mm × 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm × 6 cm × 1 cm and 120 cm × 11 cm × 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results.
Assessing pathogenicity of MLH1 variants by co-expression of human MLH1 and PMS2 genes in yeast
Energy Technology Data Exchange (ETDEWEB)
Vogelsang, Matjaz; Comino, Aleksandra; Zupanec, Neja [Department for Biosynthesis and Biotransformation, National Institute of Chemistry, Hajdrihova 19, SI-1001 Ljubljana (Slovenia); Hudler, Petra [Medical Center for Molecular Biology, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, SI-1000 Ljubljana (Slovenia); Komel, Radovan [Department for Biosynthesis and Biotransformation, National Institute of Chemistry, Hajdrihova 19, SI-1001 Ljubljana (Slovenia); Medical Center for Molecular Biology, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, SI-1000 Ljubljana (Slovenia)
2009-10-28
Loss of DNA mismatch repair (MMR) in humans, mainly due to mutations in the hMLH1 gene, is linked to hereditary nonpolyposis colorectal cancer (HNPCC). Because not all MLH1 alterations result in loss of MMR function, accurate characterization of variants and their classification in terms of their effect on MMR function is essential for reliable genetic testing and effective treatment. To date, in vivo assays for functional characterization of MLH1 mutations performed in various model systems have used episomal expression of the modified MMR genes. We describe here a novel approach to determine accurately the functional significance of hMLH1 mutations in vivo, based on co-expression of human MLH1 and PMS2 in yeast cells. Yeast MLH1 and PMS1 genes, whose protein products form the MutLα complex, were replaced by human orthologs directly on yeast chromosomes by homologous recombination, and the resulting MMR activity was tested. The yeast strain co-expressing hMLH1 and hPMS2 exhibited the same mutation rate as the wild-type. Eight cancer-related MLH1 variants were introduced, using the same approach, into the prepared yeast model, and their effect on MMR function was determined. Five variants (A92P, S93G, I219V, K618R and K618T) were classified as non-pathogenic, whereas variants T117M, Y646C and R659Q were characterized as pathogenic. Results of our in vivo yeast-based approach correlate well with clinical data in five out of seven hMLH1 variants and the described model was thus shown to be useful for functional characterization of MLH1 variants in cancer patients found throughout the entire coding region of the gene.
Assessing pathogenicity of MLH1 variants by co-expression of human MLH1 and PMS2 genes in yeast
Directory of Open Access Journals (Sweden)
Hudler Petra
2009-10-01
Full Text Available Abstract Background Loss of DNA mismatch repair (MMR in humans, mainly due to mutations in the hMLH1 gene, is linked to hereditary nonpolyposis colorectal cancer (HNPCC. Because not all MLH1 alterations result in loss of MMR function, accurate characterization of variants and their classification in terms of their effect on MMR function is essential for reliable genetic testing and effective treatment. To date, in vivo assays for functional characterization of MLH1 mutations performed in various model systems have used episomal expression of the modified MMR genes. We describe here a novel approach to determine accurately the functional significance of hMLH1 mutations in vivo, based on co-expression of human MLH1 and PMS2 in yeast cells. Methods Yeast MLH1 and PMS1 genes, whose protein products form the MutLα complex, were replaced by human orthologs directly on yeast chromosomes by homologous recombination, and the resulting MMR activity was tested. Results The yeast strain co-expressing hMLH1 and hPMS2 exhibited the same mutation rate as the wild-type. Eight cancer-related MLH1 variants were introduced, using the same approach, into the prepared yeast model, and their effect on MMR function was determined. Five variants (A92P, S93G, I219V, K618R and K618T were classified as non-pathogenic, whereas variants T117M, Y646C and R659Q were characterized as pathogenic. Conclusion Results of our in vivo yeast-based approach correlate well with clinical data in five out of seven hMLH1 variants and the described model was thus shown to be useful for functional characterization of MLH1 variants in cancer patients found throughout the entire coding region of the gene.
Assessing pathogenicity of MLH1 variants by co-expression of human MLH1 and PMS2 genes in yeast
International Nuclear Information System (INIS)
Vogelsang, Matjaz; Comino, Aleksandra; Zupanec, Neja; Hudler, Petra; Komel, Radovan
2009-01-01
Loss of DNA mismatch repair (MMR) in humans, mainly due to mutations in the hMLH1 gene, is linked to hereditary nonpolyposis colorectal cancer (HNPCC). Because not all MLH1 alterations result in loss of MMR function, accurate characterization of variants and their classification in terms of their effect on MMR function is essential for reliable genetic testing and effective treatment. To date, in vivo assays for functional characterization of MLH1 mutations performed in various model systems have used episomal expression of the modified MMR genes. We describe here a novel approach to determine accurately the functional significance of hMLH1 mutations in vivo, based on co-expression of human MLH1 and PMS2 in yeast cells. Yeast MLH1 and PMS1 genes, whose protein products form the MutLα complex, were replaced by human orthologs directly on yeast chromosomes by homologous recombination, and the resulting MMR activity was tested. The yeast strain co-expressing hMLH1 and hPMS2 exhibited the same mutation rate as the wild-type. Eight cancer-related MLH1 variants were introduced, using the same approach, into the prepared yeast model, and their effect on MMR function was determined. Five variants (A92P, S93G, I219V, K618R and K618T) were classified as non-pathogenic, whereas variants T117M, Y646C and R659Q were characterized as pathogenic. Results of our in vivo yeast-based approach correlate well with clinical data in five out of seven hMLH1 variants and the described model was thus shown to be useful for functional characterization of MLH1 variants in cancer patients found throughout the entire coding region of the gene
Safety system status monitoring
International Nuclear Information System (INIS)
Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.
1984-03-01
The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide
Safety system status monitoring
Energy Technology Data Exchange (ETDEWEB)
Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.
1984-03-01
The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.
Pavement management system for City of Madison.
2016-11-01
This project aims to implement a pavement management system (PMS) for the City of Madison using : four specific objectives: 1) build a city-wide GIS database for PMS compatible and incorporable with the : citys GIS system; 2) identify feasible pav...
Monitoring Cray Cooling Systems
Energy Technology Data Exchange (ETDEWEB)
Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL
2014-01-01
While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.
The Expert Project Management System (EPMS)
Silverman, Barry G.; Diakite, Coty
1986-01-01
Successful project managers (PMs) have been shown to rely on 'intuition,' experience, and analogical reasoning heuristics. For new PMs to be trained and experienced PMs to avoid repeating others' mistakes, it is necessary to make the knowledge and heuristics of successful PMs more widely available. The preparers have evolved a model of PM thought processes over the last decade that is now ready to be implemented as a generic PM aid. This aid consists of a series of 'specialist' expert systems (CRITIC, LIBRARIAN, IDEA MAN, CRAFTSMAN, and WRITER) that communicate with each other via a 'blackboard' architecture. The various specialist expert systems are driven to support PM training and problem solving since any 'answers' they pass to the blackboard are subjected to conflict identification (AGENDA FORMULATOR) and GOAL SETTER inference engines.
Vinogradov, Sergey; Nebot del Busto, Eduardo; Kastriotou, Maria; Welsch, Carsten P
2016-01-01
Silicon Photomultipliers (SiPMs) are well recognised as very competitive photodetectors due to their exceptional photon number and time resolution, room-temperature low-voltage operation, insensitivity to magnetic fields, compactness, and robustness. Detection of weak light pulses of nanosecond time scale appears to be the best area for SiPM applications because in this case most of the SiPM drawbacks have a rather limited effect on its performance. In contrast to the more typical scintillation and Cherenkov detection applications, which demand information on the number of photons and/or the arrival time of the light pulse only, beam loss monitoring (BLM) systems utilising Cherenkov fibres with photodetector readout have to precisely reconstruct the temporal profile of the light pulse. This is a rather challenging task for any photon detector especially taking into account the high dynamic range of incident signals (100K – 1M) from a few photons to a few percents of destructive losses in a beam line and pre...
An investigation of data management and property management systems in hotels
Kokaz Pucciani, Karolin; Murphy, Hilary Catherine
2011-01-01
The purpose of this paper is to investigate the role of Property Management Systems (PMS) for data management in hotels. The main objectives are to investigate; the awareness of different PMS software and their functionalities, the key determinants of the choice of a specific system and the effective data integration for decision making. The methodology is quantitative and examines the key dimensions of the PMS systems and their functionality. The method employed here is an online question...
Ramchander, N. C.; Ryan, N. A. J.; Crosbie, E. J.; Evans, D. G.
2017-01-01
BackgroundConstitutional mismatch repair deficiency syndrome results from bi-allelic inheritance of mutations affecting the key DNA mismatch repair genes: MLH1, MSH2, MSH6 or PMS2. Individuals with bi-allelic mutations have a dysfunctional mismatch repair system from birth; as a result, constitutional mismatch repair deficiency syndrome is characterised by early onset malignancies. Fewer than 150 cases have been reported in the literature over the past 20 years. This is the first report of th...
Evaluating penetration-monitoring systems
International Nuclear Information System (INIS)
Markin, J.T.
1981-01-01
Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors
Environmental radiation monitoring system
International Nuclear Information System (INIS)
Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi
2007-01-01
Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)
Formulation of similarity porous media systems
International Nuclear Information System (INIS)
Anderson, R.M.; Ford, W.T.; Ruttan, A.; Strauss, M.J.
1982-01-01
The mathematical formulation of the Porous Media System (PMS) describing two-phase, immiscible, compressible fluid flow in linear, homogeneous porous media is reviewed and expanded. It is shown that families of common vertex, coaxial parabolas and families of parallel lines are the only families of curves on which solutions of the PMS may be constant. A coordinate transformation is used to change the partial differential equations of the PMS to a system of ordinary differential equations, referred to as a similarity Porous Media System (SPMS), in which the independent variable denotes movement from curve to curve in a selected family of curves. Properties of solutions of the first boundary value problem are developed for the SPMS
Directory of Open Access Journals (Sweden)
Masoomeh kheirkhah
2016-11-01
Full Text Available Premenstrual syndrome (PMS encompasses a wide variety of cyclic and recurrent physical, emotional, and behavioral symptoms that occur before menstruation and has negative impact on activities of daily living, social activities, sexual functioning and quality of life. The aim of the present study was to compare the effect of omega-3 fatty acid and perforan (Hypericum perforatum on severity of premenstrual syndrome (PMS. This study is a triple-blind clinical trial that was carried out across three groups with 150 students after considering inclusion and exclusion criteria. The subjects of this study were randomly divided into three groups include omega-3 fatty acid group, perforan group and control (placebo group. Every subject in this study took drugs during three subsequent cycles so they took capsules daily in the first cycle for one month and in the second and third cycles they took them from eight days before menstruation to two days after and recorded the severity of premenstrual syndrome questionnaire. Statistical analyses were performed using SPSS version 17. The repeated measures ANOVA, chi-square and Wilcoxon tests were used to compare mean differences in three groups. The data showed that there were no significant differences between 3 groups before the intervention but 1, 2 and 3 months after consumption of perforan and omega-3 capsules, the severity of PMS was significantly lower than that in control group (p<0.001. perforan and omega-3 significantly reduce the severity of PMS.
Integrated photovoltaic (PV) monitoring system
Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti
2012-09-01
The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.
Energy Technology Data Exchange (ETDEWEB)
Oh, Se-Young, E-mail: ohs@uoguelph.ca [Department of Animal Biosciences, Ontario Agriculture College (OAC), University of Guelph, Guelph, ON N1G 2W1 (Canada); Cedergreen, Nina [Department of Life Sciences, University of Copenhagen, Frederiksberg (Denmark); Yiannikouris, Alexandros [Alltech Inc., Nicholasville, KY (United States); Swamy, H.V.L.N. [Trouw Nutrition Pvt. Ltd. India, Karnataka State 560065 (India); Karrow, Niel A., E-mail: nkarrow@uoguelph.ca [Department of Animal Biosciences, Ontario Agriculture College (OAC), University of Guelph, Guelph, ON N1G 2W1 (Canada)
2017-03-01
Penicillium mycotoxins (PMs) are toxic contaminants commonly found as mixtures in animal feed. Therefore, it is important to investigate potential joint toxicity of PM mixtures. In the present study, we assessed the joint effect of binary combinations of the following PMs: citrinin (CIT), ochratoxin A (OTA), patulin (PAT), mycophenolic acid (MPA) and penicillic acid (PA) using independent action (IA) and concentration addition (CA) concepts. Previously published toxicity data (i.e. IC25; PM concentration that inhibited bovine macrophage (BoMacs) proliferation by 25%) were initially analyzed, and both concepts agreed that OTA + PA demonstrated synergism (p < 0.05), while PAT + PA showed antagonism (p < 0.05). When a follow-up dilution study was carried out using binary combinations of PMs at three different dilution levels (i.e. IC25, 0.5 ∗ IC25, 0.25 ∗ IC25), only the mixture of CIT + OTA at 0.5 ∗ IC25 was determined to have synergism by both IA and CA concepts with Model Deviation Ratios (MDRs; the ratio of predicted versus observed effect concentrations) of 1.4 and 1.7, respectively. The joint effect of OTA + MPA, OTA + PA and CIT + PAT complied with the IA concept, while CIT + PA, PAT + MPA and PAT + PA were better predicted with the CA over the IA concept. The present study suggests to test both IA and CA concepts using multiple doses when assessing risk of mycotoxin mixtures if the mode of action is unknown. In addition, the study showed that the tested PMs could be predicted by IA or CA within an approximate two-fold certainty, raising the possibility for a joint risk assessment of mycotoxins in food and feed. - Highlights: • We investigated the potential joint toxicity of Penicillium mycotoxin (PM) mixtures. • Independent action (IA) and concentration addition (CA) concepts were used. • 7 out of 10 mixtures followed joint toxicity described by IA or CA concepts. • Both concepts agreed that CIT + OTA mixture had synergistic interaction.
International Nuclear Information System (INIS)
Oh, Se-Young; Cedergreen, Nina; Yiannikouris, Alexandros; Swamy, H.V.L.N.; Karrow, Niel A.
2017-01-01
Penicillium mycotoxins (PMs) are toxic contaminants commonly found as mixtures in animal feed. Therefore, it is important to investigate potential joint toxicity of PM mixtures. In the present study, we assessed the joint effect of binary combinations of the following PMs: citrinin (CIT), ochratoxin A (OTA), patulin (PAT), mycophenolic acid (MPA) and penicillic acid (PA) using independent action (IA) and concentration addition (CA) concepts. Previously published toxicity data (i.e. IC25; PM concentration that inhibited bovine macrophage (BoMacs) proliferation by 25%) were initially analyzed, and both concepts agreed that OTA + PA demonstrated synergism (p < 0.05), while PAT + PA showed antagonism (p < 0.05). When a follow-up dilution study was carried out using binary combinations of PMs at three different dilution levels (i.e. IC25, 0.5 ∗ IC25, 0.25 ∗ IC25), only the mixture of CIT + OTA at 0.5 ∗ IC25 was determined to have synergism by both IA and CA concepts with Model Deviation Ratios (MDRs; the ratio of predicted versus observed effect concentrations) of 1.4 and 1.7, respectively. The joint effect of OTA + MPA, OTA + PA and CIT + PAT complied with the IA concept, while CIT + PA, PAT + MPA and PAT + PA were better predicted with the CA over the IA concept. The present study suggests to test both IA and CA concepts using multiple doses when assessing risk of mycotoxin mixtures if the mode of action is unknown. In addition, the study showed that the tested PMs could be predicted by IA or CA within an approximate two-fold certainty, raising the possibility for a joint risk assessment of mycotoxins in food and feed. - Highlights: • We investigated the potential joint toxicity of Penicillium mycotoxin (PM) mixtures. • Independent action (IA) and concentration addition (CA) concepts were used. • 7 out of 10 mixtures followed joint toxicity described by IA or CA concepts. • Both concepts agreed that CIT + OTA mixture had synergistic interaction.
Betancourt, C.; Brundler, R.; Dätwyler, A.; Favre, Y.; Gascon, D.; Gomez, S.; Korzenev, Alexander; Mermod, P.; Noah, E.; Serra, N.; Sgalaberna, D.; Storaci, B.
2017-11-27
In this study an array of eight 6 mm × 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm × 6 cm × 1 cm and 120 cm × 11 cm × 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results.
Calibration and monitoring of a scintillator HCAL with SiPMs CALICE scintillator HCAL
International Nuclear Information System (INIS)
Lucaci-Timoce, Angela
2009-01-01
The operational experience with a highly-granular analogue hadronic calorimeter (AHCAL) consisting of 7608 individual scintillator tiles readout via Silicon-Photo-multipliers (SiPM) is presented. The calibration of each cell is based on minimum ionizing particle signals for which in general a muon beam is used. In addition, a correction for the non-linearity introduced by the finite number of pixels (1156) in the SiPM is applied. The aspects of temperature and voltage dependence of SiPM are addressed, and monitoring and calibration procedures are discussed. Such procedures are essential for the extrapolation of calibration factors over several days of data taking with the calorimeter. For this purpose a versatile UV-LED light distribution system was developed, capable of delivering light to all tiles with intensity from a few photo-electrons to the saturation of the SiPM. The procedures are tested using data collected with the AHCAL at the CERN SPS test beam.
Shia, Jinru; Zhang, Liying; Shike, Moshe; Guo, Min; Stadler, Zsofia; Xiong, Xiaoling; Tang, Laura H; Vakiani, Efsevia; Katabi, Nora; Wang, Hangjun; Bacares, Ruben; Ruggeri, Jeanine; Boland, C Richard; Ladanyi, Marc; Klimstra, David S
2013-01-01
Immunohistochemical staining for DNA mismatch repair proteins may be affected by various biological and technical factors. Staining variations that could potentially lead to erroneous interpretations have been recognized. A recently recognized staining variation is the significant reduction of staining for MSH6 in some colorectal carcinomas. The frequency and specific characteristics of this aberrant MSH6 staining pattern, however, have not been well analyzed. In this study of 420 colorectal carcinoma samples obtained from patients fulfilling the Revised Bethesda Guidelines, we detected 9 tumors (2%) showing extremely limited staining for MSH6 with positive staining present in PMS2 protein-deficient carcinomas (n=5, including 1 with a pathogenic mutation in PMS2); and (2) MLH1, PMS2 and MSH2 normal but with chemotherapy or chemoradiation therapy before surgery (n=4). To test our hypothesis that somatic mutation in the coding region microsatellite of the MSH6 gene might be a potential underlying mechanism for such limited MSH6 staining, we evaluated frameshift mutation in a (C)(8) tract in exon 5 of the MSH6 gene in seven tumors that had sufficient DNA for analysis, and detected mutation in four; all four tumors belonged to the MLH1/PMS2-deficient group. In conclusion, our data outline the main scenarios where significant reduction of MSH6 staining is more likely to occur in colorectal carcinoma, and suggest that somatic mutations of the coding region microsatellites of the MSH6 gene is an underlying mechanism for this staining phenomenon in MLH1/PMS2-deficient carcinomas.
Sjursen, Wenche; Bjørnevoll, Inga; Engebretsen, Lars F; Fjelland, Kristine; Halvorsen, Tore; Myrvold, Helge E
2009-01-01
Turcot syndrome is a rare, inherited disease predisposing of tumours in the central nerve system and in the colorectal system. This report describes a Turcot patient with an extraordinary clinical history. The patient is still alive at the age of 43. She was operated at the age of 10 by brain tumour and at the age of 16 by colorectal cancer. She has since then been treated for multiple cancers (gastrointestinal, endometrial, basal cell carcinomas), and removal of adenomatous polyps at several occasions. The aim of this work was to investigate if there was any specific genotype that explains her remarkable clinical history. Microsatellite instability and immunohistochemistry analysis for four DNA mismatch repair proteins were performed. DNA mutation analysis was done for genes involved in polyposis and mismatch repair by denaturing high performance liquid chromatography and sequencing. cDNA analysis was carried out for the mismatch repair gene PMS2. The patients genotype was found to be a homozygous splice site mutation in the PMS2 gene, c.989-1G
Inductive Monitoring System (IMS)
National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...
CERN safety system monitoring - SSM
International Nuclear Information System (INIS)
Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.
2012-01-01
CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)
Copilot: Monitoring Embedded Systems
Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn
2012-01-01
Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.
Kato, Aya; Sato, Naoki; Sugawara, Tae; Takahashi, Kazue; Kito, Masahiko; Makino, Kenichi; Sato, Toshiharu; Shimizu, Dai; Shirasawa, Hiromitu; Miura, Hiroshi; Sato, Wataru; Kumazawa, Yukiyo; Sato, Akira; Kumagai, Jin; Terada, Yukihiro
2016-01-01
Lynch syndrome (LS) is an autosomal dominant inherited disorder mainly caused by a germline mutation in the DNA mismatch repair (MMR) genes (MLH1, MSH2, MSH6, PMS2) and is associated with increased risk of various cancers, particularly colorectal cancer and endometrial cancer (EC). Women with LS account for 2–6% of EC patients; it is clinically important to identify LS in such individuals for predicting and/or preventing additional LS-associated cancers. PMS2 germline mutation ...
Waste monitoring system for effluents
International Nuclear Information System (INIS)
Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.
1995-07-01
The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system
Kosinski, Jan; Hinrichsen, Inga; Bujnicki, Janusz M; Friedhoff, Peter; Plotz, Guido
2010-08-01
Missense alterations of the mismatch repair gene MLH1 have been identified in a significant proportion of individuals suspected of having Lynch syndrome, a hereditary syndrome that predisposes for cancer of colon and endometrium. The pathogenicity of many of these alterations, however, is unclear. A number of MLH1 alterations are located in the C-terminal domain (CTD) of MLH1, which is responsible for constitutive dimerization with PMS2. We analyzed which alterations may result in pathogenic effects due to interference with dimerization. We used a structural model of CTD of MLH1-PMS2 heterodimer to select 19 MLH1 alterations located inside and outside two candidate dimerization interfaces in the MLH1-CTD. Three alterations (p.Gln542Leu, p.Leu749Pro, p.Tyr750X) caused decreased coexpression of PMS2, which is unstable in the absence of interaction with MLH1, suggesting that these alterations interfere with dimerization. All three alterations are located within the dimerization interface suggested by our model. They also compromised mismatch repair, suggesting that defects in dimerization abrogate repair and confirming that all three alterations are pathogenic. Additionally, we provided biochemical evidence that four alterations with uncertain pathogenicity (p.Ala586Pro, p.Leu636Pro, p.Thr662Pro, and p.Arg755Trp) are deleterious because of poor expression or poor repair efficiency, and confirm the deleterious effect of eight further alterations.
A new advanced software platform for nuclear power plant process information systems
International Nuclear Information System (INIS)
Sorsa, A.
1993-01-01
In the late 80s, ABB Stromberg Power Ltd. started the development of a new generation software platform for the power plant Process Information System (PIS). This development resulted in a software platform called Procontrol PMS. Procontrol PMS is a platform for fully distributed systems which provides the following features: distributed data processing, non-stop architecture, low-cost incremental expansion path, open network architecture, high functionality, effective application development environment, and advanced user interface services. A description of the structure of the Procontrol PMS software is given. ABB has received by May 1992 six orders for nuclear power plant PISs based on Procontrol PMS (4 for PWR plants, 2 for BWRs). The first Procontrol PMS based nuclear power plant PIS was commissioned in 1989 at the Loviisa nuclear power plant and has been running with 100% availability since the commissioning. (Z.S.) 2 figs
Energy Technology Data Exchange (ETDEWEB)
NONE
1996-02-01
Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.
Environmental monitoring and information systems
International Nuclear Information System (INIS)
Gibbert, R.
1998-01-01
Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)
International Nuclear Information System (INIS)
Xing, Liudong; Levitin, Gregory
2013-01-01
Phased-mission systems (PMS) are systems in which multiple non-overlapping phases of operations (or tasks) are accomplished in sequence for a successful mission. Examples of PMS abound in applications such as aerospace, nuclear power, and airborne weapon systems. Reliability analysis of a PMS must consider statistical dependence across different phases as well as dynamics in system configuration, failure criteria, and component behavior. This paper proposes a binary decision diagrams (BDD) based method for the reliability evaluation of non-repairable binary-state PMS with common-cause failures (CCF). CCF are simultaneous failure of multiple system elements, which can be caused by some external factors (e.g., lightning strikes, sudden changes in environment) or by propagated failures originating from some elements within the system. Both the external and internal CCF is considered in this paper. The proposed method is combinatorial, exact, and is applicable to PMS with arbitrary system structures and component failure distributions. An example with different CCF scenarios is analyzed to illustrate the application and advantages of the proposed method. -- Highlights: ► Non-repairable phased-mission systems with common-cause failures are analyzed. ► Common-cause failures caused by internal or external factors are considered. ► A combinatorial algorithm based on binary decision diagrams is suggested
Data monitoring system of technical diagnosis system for EAST
International Nuclear Information System (INIS)
Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong
2010-01-01
Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)
The JOYO remote monitoring system
International Nuclear Information System (INIS)
Damico, Joseph P.; Hashimoto, Yu
2000-01-01
The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)
Unattended Monitoring System Design Methodology
International Nuclear Information System (INIS)
Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.
1999-01-01
A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations
Savannah River Plant remote environmental monitoring system
International Nuclear Information System (INIS)
Schubert, J.F.
1987-01-01
The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes
Lindsay, Holly; Jubran, Rima F; Wang, Larry; Kipp, Benjamin R; May, William A
2013-08-01
We describe a 12-year-old girl, simultaneously presenting with colonic adenocarcinoma and medulloblastoma from bialleic deletions in the mismatch repair gene PMS2. Her distinctive physical and clinical findings are characteristic of constitutional mismatch repair deficiency syndrome. Earlier recognition of such findings may permit better screening and more effective treatment. Copyright © 2013 Mosby, Inc. All rights reserved.
Influence of Organization Management on Systems of Performance Measurement and Management Control
Directory of Open Access Journals (Sweden)
Zora Říhová
2015-06-01
Full Text Available This article is focused on investigating the influence of organization management on Performance Measurement Systems (PMS and Management Control Systems (MCS. The goal of the paper is to draw attention to the fact that designing PMS the validity of which could not be disputed, needs to correctly determine the organization structure and the role competences. In the example of matrix structures are shown some of the difficulties that may distort the results obtained from these systems. PMS + MCS is to be created after a thorough critical analysis of the organizational structure and set competences.
Roberts, Maegan E; Jackson, Sarah A; Susswein, Lisa R; Zeinomar, Nur; Ma, Xinran; Marshall, Megan L; Stettner, Amy R; Milewski, Becky; Xu, Zhixiong; Solomon, Benjamin D; Terry, Mary Beth; Hruska, Kathleen S; Klein, Rachel T; Chung, Wendy K
2018-01-18
PurposeAn association of Lynch syndrome (LS) with breast cancer has been long suspected; however, there have been insufficient data to address this question for each of the LS genes individually.MethodsWe conducted a retrospective review of personal and family history in 423 women with pathogenic or likely pathogenic germ-line variants in MLH1 (N = 65), MSH2 (N = 94), MSH6 (N = 140), or PMS2 (N = 124) identified via clinical multigene hereditary cancer testing. Standard incidence ratios (SIRs) of breast cancer were calculated by comparing breast cancer frequencies in our study population with those in the general population (Surveillance, Epidemiology, and End Results 18 data).ResultsWhen evaluating by gene, the age-standardized breast cancer risks for MSH6 (SIR = 2.11; 95% confidence interval (CI), 1.56-2.86) and PMS2 (SIR = 2.92; 95% CI, 2.17-3.92) were associated with a statistically significant risk for breast cancer whereas no association was observed for MLH1 (SIR = 0.87; 95% CI, 0.42-1.83) or MSH2 (SIR = 1.22; 95% CI, 0.72-2.06).ConclusionOur data demonstrate that two LS genes, MSH6 and PMS2, are associated with an increased risk for breast cancer and should be considered when ordering genetic testing for individuals who have a personal and/or family history of breast cancer.GENETICS in MEDICINE advance online publication, 18 January 2018; doi:10.1038/gim.2017.254.
Arduino Based Infant Monitoring System
Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi
2017-08-01
This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.
Directory of Open Access Journals (Sweden)
Shamekh R
2016-08-01
Full Text Available Rania Shamekh,1 Mauro Cives,2 Jaime Mejia,3 Domenico Coppola,4 1Department of Pathology, University of South Florida, 2Department of Gastrointestinal Oncology, Moffitt Cancer Center, Tampa, FL, USA; 3Department of Pathology, Institutode Patologia Mejia Jimenez, Cali, Colombia; 4Department of Anatomic Pathology, Moffitt Cancer Center, Tampa, FL, USA Abstract: Colorectal cancer (CRC is the third most common cancer and the fourth most common cause of death worldwide. It accounts for >9% of all cancers. One of the pathogenic factors of CRC is germline mutation, leading to alteration and inactivation in the mismatch repair (MMR genes. The aim of the study is to compare the frequency of alterations in MMR protein expression in Caucasian CRC patients with Colombian CRC patients. A total of 45 Colombians and 48 Caucasians with CRC were studied. The microsatellite instability status of tumors was determined in primary CRC by immunohistochemistry using the automated Ventana Ultra. The combined loss of MLH1 and PMS2 was the most common alteration in both Colombian (11%, five out of 45 and Caucasian (12%, six out of 48 CRC patients. Interestingly, the loss of PMS2 expression in the presence of intact MLH1 was the second most common alteration in Colombians (8%, four out of 45, which was never seen in the Caucasian cohort (P=0.05. The loss of MLH1 alone and the combined loss of MSH6 and PMS2 expression were only observed in one out of 45 (2% Colombians but not in Caucasians. The combined loss of MSH2 and MSH6 was not observed in any of the patients studied. The preliminary findings support a significant difference in alterations of MMR protein expression in Colombian CRC patients compared with Caucasian CRC patients. These findings are novel and warrant further studies in larger cohorts. Keywords: colon cancer, MSI, MMR, immunohistochemistry
On Representing Instance Changes in Adaptive Process Management Systems.
Rinderle, S.B.; Kreher, U; Lauer, M.; Dadam, P.; Reichert, M.U.
2006-01-01
By separating the process logic from the application code process management systems (PMS) offer promising perspectives for automation and management of business processes. However, the added value of PMS strongly depends on their ability to support business process changes which can affect the
Performance evaluation of project management system based on combination of EFQM and QFD
Directory of Open Access Journals (Sweden)
Amin Ahmadi Digehsara
2018-09-01
Full Text Available Project management system (PMS is broadly recognized as the effective management tool for several organizations. European Foundation of Quality Management (EFQM model provides some advantages for companies to be successful in current competitive environment. This paper is based on the combination of EFQM and Quality function deployment (QFD in order to eval-uate a PMS in an aviation organization. Although, an integration of these models increases the system complexity, the implementation of EFQM-QFD helps us identify all noteworthy success factors of PMS within the organization. In addition, the current status of PMS performance is evaluated based on these factors. This study attempts to find out how organizations ought to be managed to take full advantage of PMS tools. This study uses a comprehensive questionnaire to find all critical factors influencing on the success of the organization. The method of this paper is implemented in an organization in aviation industry with several management departments.
Absence of regulation of tumor cholesterogenesis in cell-free synthesizing systems
International Nuclear Information System (INIS)
Azrolan, N.; Coleman, P.S.
1986-01-01
In tumors, cholesterol synthesis de novo is deregulated relative to normal tissues. But no previous study has demonstrated the decontrol of tumor cholesterogenesis with cell-free cytosolic systems. They have utilized a lipid synthesizing, post-mitochondrial supernatant system (PMS), with 14 C-citrate as substrate, to characterize the cholesterogenic pathway in Morris Hepatoma 3924A and normal rat liver. The rate of cholesterogenesis in the hepatoma PMS was 6-fold higher than that in the liver system on a per cell basis. The ratio of sterol-to-fatty acid synthesis was also significantly greater in the tumor versus the liver PMS. The authors determined the steady-state carbon flux through the early intermediates of the lipogenic pathways. Whereas the liver system displayed a metabolic crossover point at the HMG-CoA reductase reaction, the hepatoma system showed no evidence of control at this rate-limiting site of sterol synthesis. Furthermore, acetyl-CoA formation from added citrate (via ATP-citrate lyase) exhibited rates of 42% and 88% in excess of that required for lipidogenesis by liver and tumor PMS systems, respectively. Clearly, a cell-free PMS system from tumor tissue displays the property of deregulated lipidogenesis, especially cholesterol biosynthesis. The authors suggest that deregulated and continuously operating cholesterogenesis would provide for an increased level of a mevalonate-derived sterol pathway intermediate proposed as a trigger for DNA synthesis and cell proliferation in tumors
Docobo, J. A.; Tamazian, V. S.; Campo, P. P.
2018-05-01
In the vast majority of cases when available astrometric measurements of a visual binary cover a very short orbital arc, it is practically impossible to calculate a good quality orbit. It is especially important for systems with pre-main-sequence components where standard mass-spectrum calibrations cannot be applied nor can a dynamical parallax be calculated. We have shown that the analytical method of Docobo allows us to put certain constraints on the most likely orbital solutions, using an available realistic estimate of the global mass of the system. As an example, we studied the interesting PMS binary, FW Tau AB, located in the Taurus-Auriga as well as investigated a range of its possible orbital solutions combined with an assumed distance between 120 and 160 pc. To maintain the total mass of FW Tau AB in a realistic range between 0.2 and 0.6M_{⊙}, minimal orbital periods should begin at 105, 150, 335, and 2300 yr for distances of 120, 130, 140, and 150 pc, respectively (no plausible orbits were found assuming a distance of 160 pc). An original criterion to establish the upper limit of the orbital period is applied. When the position angle in some astrometric measurements was flipped by 180°, orbits with periods close to 45 yr are also plausible. Three example orbits with periods of 44.6, 180, and 310 yr are presented.
Haraldsdottir, Sigurdis; Rafnar, Thorunn; Frankel, Wendy L; Einarsdottir, Sylvia; Sigurdsson, Asgeir; Hampel, Heather; Snaebjornsson, Petur; Masson, Gisli; Weng, Daniel; Arngrimsson, Reynir; Kehr, Birte; Yilmaz, Ahmet; Haraldsson, Stefan; Sulem, Patrick; Stefansson, Tryggvi; Shields, Peter G; Sigurdsson, Fridbjorn; Bekaii-Saab, Tanios; Moller, Pall H; Steinarsdottir, Margret; Alexiusdottir, Kristin; Hitchins, Megan; Pritchard, Colin C; de la Chapelle, Albert; Jonasson, Jon G; Goldberg, Richard M; Stefansson, Kari
2017-05-03
Lynch syndrome, caused by germline mutations in the mismatch repair genes, is associated with increased cancer risk. Here using a large whole-genome sequencing data bank, cancer registry and colorectal tumour bank we determine the prevalence of Lynch syndrome, associated cancer risks and pathogenicity of several variants in the Icelandic population. We use colorectal cancer samples from 1,182 patients diagnosed between 2000-2009. One-hundred and thirty-two (11.2%) tumours are mismatch repair deficient per immunohistochemistry. Twenty-one (1.8%) have Lynch syndrome while 106 (9.0%) have somatic hypermethylation or mutations in the mismatch repair genes. The population prevalence of Lynch syndrome is 0.442%. We discover a translocation disrupting MLH1 and three mutations in MSH6 and PMS2 that increase endometrial, colorectal, brain and ovarian cancer risk. We find thirteen mismatch repair variants of uncertain significance that are not associated with cancer risk. We find that founder mutations in MSH6 and PMS2 prevail in Iceland unlike most other populations.
International Nuclear Information System (INIS)
Reneke, J.A.; Fryer, M.O.
1995-01-01
Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection
Characterization of UV-enhanced SiPMs for Imaging in High Pressure Xenon Electroluminescent TPC
International Nuclear Information System (INIS)
Yahlali, Nadia; Lorca, David; Fernandes, L.M.P.
2013-06-01
The possibility of recording charged particle tracks in an electro-luminescent xenon gas TPC is investigated using a SiPM-based tracking system, operated in the demonstrator prototype of the NEXT-100 ββ decay experiment. The tracks of the ββ0ν events from the decay of the 136 Xe isotope have a distinctive topology, which allows their discrimination against single-electron events from the natural radioactivity that populates the region of interest of the neutrinoless decay in the ββ energy spectrum. Combined to the near-intrinsic energy resolution of the gaseous detector, this tracking capability provides a powerful background rejection tool for the search of the neutrinoless ββ decay aimed by the experiment. The NEXT-100 detector concepts and sensitivity and the first results of its demonstrator prototype are presented. The characterization studies relevant for the operation of UV-enhanced SiPMs used for imaging in an electro-luminescent TPC are reviewed. (authors)
Integrated Monitoring System of Production Processes
Directory of Open Access Journals (Sweden)
Oborski Przemysław
2016-12-01
Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.
International Nuclear Information System (INIS)
Yoon, Seokjin; Choi, Jiwon; Choi, Jooyoung; Wan, Dandan; Li, Qian; Yang, Ying
2010-01-01
0.90Pb(Zr 0.48 Ti 0.52 )O 3 -0.05Pb(Mn 1/3 Sb 2/3 )O 3 -0.05Pb(Zn 1/3 Nb 2/3 )O 3 quaternary piezoelectric ceramics with CuO added were synthesized by using a conventional method at low sintering temperatures. CuO additive, 1.0 wt%, significantly improves the sinterability of 0.90PZT-0.05PMS-0.05PZN ceramics, lowering the sintering temperature to 900 .deg. C and showing moderate electrical properties: d 33 = 306 pC/N, Q m = 997, k p = 53.6%, tanδ = 0.50%, and ε T 33 = 1351. To obtain more optimal piezoelectric properties, we selected Bi 2 O 3 and Nb 2 O 5 as donor dopants to introduce a softening effect. The crystal structure, micro-morphology and electrical properties were studied in terms of the Bi 2 O 3 and the Nb 2 O 5 contents. Our study demonstrates that Bi 2 O 3 is very effective in improving the piezoelectric properties, causing a significant enhancement in d 33 and k p values. Particularly, 0.75-wt%-Bi 2 O 3 -added 0.90PZT-0.05PMS-0.05PZN + 1.0 wt% CuO ceramics show excellent electrical properties: d 33 = 363 pC/N, Q m = 851, k p = 59.3%, tanδ = 0.38%, and ε T 33 = 1596. On the other hand, the effect of Nb 2 O 5 on the piezoelectric properties is very complicated, 0.50 wt% Nb 2 O 5 doped 0.90PZT-0.05PMS-0.05PZN + 1.0 wt% CuO ceramics have a remarkable improvement in k p value and maintain good electrical properties: d 33 = 300 pC/N, Q m = 971, k p = 58.4%, tanδ = 0.36%, and ε T 33 = 1332.
Maintenance of radiation monitoring systems
International Nuclear Information System (INIS)
Aoyama, Kei
2001-01-01
As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)
Herkert, Johanna C; Niessen, Renée C; Olderode-Berends, Maria J W; Veenstra-Knol, Hermine E; Vos, Yvonne J; van der Klift, Heleen M; Scheenstra, Rene; Tops, Carli M J; Karrenbeld, Arend; Peters, Frans T M; Hofstra, Robert M W; Kleibeuker, Jan H; Sijmons, Rolf H
BACKGROUND: Bi-allelic germline mutations of one of the DNA mismatch repair genes, so far predominantly found in PMS2, cause constitutional MMR-deficiency syndrome. This rare disorder is characterised by paediatric intestinal cancer and other malignancies. We report the clinical, immunohistochemical
Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor
DEFF Research Database (Denmark)
Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming
2012-01-01
A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...
Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor
International Nuclear Information System (INIS)
Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian
2012-01-01
A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)
The Danish Marine Monitoring System
DEFF Research Database (Denmark)
Ærtebjerg, G.
1997-01-01
Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....
Suerink, Manon; van der Klift, Heleen M; Ten Broeke, Sanne W; Dekkers, Olaf M; Bernstein, Inge; Capellá Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G W; Menko, Fred H; Lindblom, Annika; Mensenkamp, Arjen; Moller, Pal; van Os, Theo A; Rahner, Nils; Redeker, Bert J W; Olderode-Berends, M J W; Olderode, Maran; Spruijt, Liesbeth; Vos, Yvonne J; Wagner, Anja; Morreau, Hans; Hes, Frederik J; Vasen, Hans F A; Tops, Carli M; Wijnen, Juul T; Nielsen, Maartje
2016-04-01
Lynch syndrome (LS), a heritable disorder with an increased risk of primarily colorectal cancer (CRC) and endometrial cancer (EC), can be caused by mutations in the PMS2 gene. We wished to establish whether genotype and/or parent-of-origin effects (POE) explain (part of) the reported variability in severity of the phenotype. European PMS2 mutation carriers (n = 381) were grouped and compared based on RNA expression and whether the mutation was inherited paternally or maternally. Mutation carriers with loss of RNA expression (group 1) had a significantly lower age at CRC diagnosis (51.1 years vs. 60.0 years, P = 0.035) and a lower age at EC diagnosis (55.8 years vs. 61.0 years, P = 0.2, nonsignificant) compared with group 2 (retention of RNA expression). Furthermore, group 1 showed slightly higher, but nonsignificant, hazard ratios (HRs) for both CRC (HR: 1.31, P = 0.38) and EC (HR: 1.22, P = 0.72). No evidence for a significant parent-of-origin effect was found for either CRC or EC. PMS2 mutation carriers with retention of RNA expression developed CRC 9 years later than those with loss of RNA expression. If confirmed, this finding would justify a delay in surveillance for these cases. Cancer risk was not influenced by a parent-of-origin effect.Genet Med 18 4, 405-409.
Computer-controlled radiation monitoring system
International Nuclear Information System (INIS)
Homann, S.G.
1994-01-01
A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable
Energy Technology Data Exchange (ETDEWEB)
Dr. Russ Braunling
2004-10-31
The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.
Business School's Performance Management System Standards Design
Azis, Anton Mulyono; Simatupang, Togar M.; Wibisono, Dermawan; Basri, Mursyid Hasan
2014-01-01
This paper aims to compare various Performance Management Systems (PMS) for business school in order to find the strengths of each standard as inputs to design new model of PMS. There are many critical aspects and gaps notified for new model to improve performance and even recognized that self evaluation performance management is not well…
Gas House Autonomous System Monitoring
Miller, Luke; Edsall, Ashley
2015-01-01
Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.
Coolant monitoring systems for PWR reactors
International Nuclear Information System (INIS)
Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.
1987-01-01
The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated
Monitoring of Danish marketed solar heating systems
International Nuclear Information System (INIS)
Ellehauge, K.
1993-01-01
The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)
Radiation monitor system for nuclear power plants
International Nuclear Information System (INIS)
Wu Bingzhe; Guo Shusheng
1990-12-01
The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants
Monitoring system and methods for a distributed and recoverable digital control system
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2010-01-01
A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.
A compact muon tracking system for didactic and outreach activities
Energy Technology Data Exchange (ETDEWEB)
Antolini, R.; Candela, A.; Conicella, V.; De Deo, M.; D' Incecco, M.; Sablone, D. [INFN Gran Sasso National Laboratory – Assergi (AQ) (Italy); Arneodo, F.; Benabderrahmane, M.L.; Di Giovanni, A. [New York University Abu Dhabi - Abu Dhabi (United Arab Emirates); Pazos Clemens, L., E-mail: luis.pazclem@nyu.edu [New York University Abu Dhabi - Abu Dhabi (United Arab Emirates); Franchi, G.; D' Inzeo, M. [Age Scientific srl – Capezzano Pianore (Italy)
2016-07-11
We present a cosmic ray telescope based on the use of plastic scintillator bars coupled to ASD-RGB1S-M Advansid Silicon Photomultipliers (SiPM) through wavelength shifter fibers. The system is comprised of 200 electronic channels organized into 10 couples of orthogonal planes allowing the 3D reconstruction of crossing muons. Two monolithic PCB boards have been designed to bias, readout all the SiPMs enclosed in the system, to monitor the working parameters and to remotely connect the detector. To make easier the display of muon tracks to non-expert users, two LED matrices, triggered by particle interactions, have been implemented. To improve the usability of the muon telescope, a controller board unit permits to select different levels of trigger and allows data acquisition for refined analyses for the more proficient user. A first prototype, funded by INFN and deployed in collaboration with NYUAD, is operating at the Toledo Metro station of Naples, while two further detectors will be developed and installed in Abu Dhabi in the next few months. - Highlights: • A compact system for real time displaying of muon tracks is presented. • The system is based on scintillating plates composed of doped polystyrene bars. • By using SiPMs and corresponding LEDs the muon paths can be visualized. • The purpose of this system is to introduce the public to sub-nuclear particles.
A compact muon tracking system for didactic and outreach activities
International Nuclear Information System (INIS)
Antolini, R.; Candela, A.; Conicella, V.; De Deo, M.; D' Incecco, M.; Sablone, D.; Arneodo, F.; Benabderrahmane, M.L.; Di Giovanni, A.; Pazos Clemens, L.; Franchi, G.; D'Inzeo, M.
2016-01-01
We present a cosmic ray telescope based on the use of plastic scintillator bars coupled to ASD-RGB1S-M Advansid Silicon Photomultipliers (SiPM) through wavelength shifter fibers. The system is comprised of 200 electronic channels organized into 10 couples of orthogonal planes allowing the 3D reconstruction of crossing muons. Two monolithic PCB boards have been designed to bias, readout all the SiPMs enclosed in the system, to monitor the working parameters and to remotely connect the detector. To make easier the display of muon tracks to non-expert users, two LED matrices, triggered by particle interactions, have been implemented. To improve the usability of the muon telescope, a controller board unit permits to select different levels of trigger and allows data acquisition for refined analyses for the more proficient user. A first prototype, funded by INFN and deployed in collaboration with NYUAD, is operating at the Toledo Metro station of Naples, while two further detectors will be developed and installed in Abu Dhabi in the next few months. - Highlights: • A compact system for real time displaying of muon tracks is presented. • The system is based on scintillating plates composed of doped polystyrene bars. • By using SiPMs and corresponding LEDs the muon paths can be visualized. • The purpose of this system is to introduce the public to sub-nuclear particles.
Energy Technology Data Exchange (ETDEWEB)
Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)
2010-04-01
This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.
International Nuclear Information System (INIS)
Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir
2010-01-01
This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.
The CUORE slow monitoring systems
Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.
2017-09-01
CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.
Data-Driven Process Control and Exception Handling in Process Management Systems
Rinderle, S.B.; Reichert, M.U.; Dubois, E.; Pohl, K.
Business processes are often characterized by high variability and dynamics, which cannot be always captured in contemporary process management systems (PMS). Adaptive PMS have emerged in recent years, but do not completely solve this problem. In particular, users are not adequately supported in
An intelligent fetal monitoring system
International Nuclear Information System (INIS)
Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.
1986-01-01
An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper
Distributed Monitoring System Based on ICINGA
Haen, C; Neufeld, N
2011-01-01
The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.
International Nuclear Information System (INIS)
Rose, C.R.; Fortgang, C.M.; Power, J.P.
1992-01-01
The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper
International Nuclear Information System (INIS)
Rose, C.R.; Fortgang, C.M.; Power, J.P.
1992-01-01
The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref
Offsite emergency radiological monitoring system and technology
International Nuclear Information System (INIS)
Mao Yongze
1994-01-01
The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries
System specification for the integrated monitoring and surveillance system
International Nuclear Information System (INIS)
1997-09-01
This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides
ERMS - Environmental Radiation Monitoring System
International Nuclear Information System (INIS)
Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan
2008-01-01
A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)
Directory of Open Access Journals (Sweden)
Lampreia, João
2017-05-01
Full Text Available The effects of Performance Measurement Systems (PMS on people’s behaviour are relevant for an organization performance and success. Yet motivational and behavioural consequences of PMS are far from being understood. This study aims to go further regarding the consequences on people’s behaviour of using PMS in organizations. In order to collect data researchers conducted a case study in a Portuguese multi-national company. Evidence shows that the way in which managers understand a PMS influences in a significant way how they behave. The data also lends support to the claim that PMS influence motivation, perceptions, participation and job-related stress of managers.
Program Management System manual
International Nuclear Information System (INIS)
1986-01-01
The Program Management System (PMS), as detailed in this manual, consists of all the plans, policies, procedure, systems, and processes that, taken together, serve as a mechanism for managing the various subprograms and program elements in a cohesive, cost-effective manner. The PMS is consistent with the requirements of the Nuclear Waste Policy Act of 1982 and the ''Mission Plan for the Civilian Radioactive Waste Management Program'' (DOE/RW-0005). It is based on, but goes beyond, the Department of Energy (DOE) management policies and procedures applicable to all DOE programs by adapting these directives to the specific needs of the Civilian Radioactive Waste Management program. This PMS Manual describes the hierarchy of plans required to develop and maintain the cost, schedule, and technical baselines at the various organizational levels of the Civilian Radioactive Waste Management Program. It also establishes the management policies and procedures used in the implementation of the Program. These include requirements for internal reports, data, and other information; systems engineering management; regulatory compliance; safety; quality assurance; and institutional affairs. Although expanded versions of many of these plans, policies, and procedures are found in separate documents, they are an integral part of this manual. The PMS provides the basis for the effective management that is needed to ensure that the Civilian Radioactive Waste Management Program fulfills the mandate of the Nuclear Waste Policy Act of 1982. 5 figs., 2 tabs
Haraldsdottir, Sigurdis; Rafnar, Thorunn; Frankel, Wendy L.; Einarsdottir, Sylvia; Sigurdsson, Asgeir; Hampel, Heather; Snaebjornsson, Petur; Masson, Gisli; Weng, Daniel; Arngrimsson, Reynir; Kehr, Birte; Yilmaz, Ahmet; Haraldsson, Stefan; Sulem, Patrick; Stefansson, Tryggvi; Shields, Peter G.; Sigurdsson, Fridbjorn; Bekaii-Saab, Tanios; Moller, Pall H.; Steinarsdottir, Margret; Alexiusdottir, Kristin; Hitchins, Megan; Pritchard, Colin C.; de la Chapelle, Albert; Jonasson, Jon G.; Goldberg, Richard M.; Stefansson, Kari
2017-01-01
Lynch syndrome, caused by germline mutations in the mismatch repair genes, is associated with increased cancer risk. Here using a large whole-genome sequencing data bank, cancer registry and colorectal tumour bank we determine the prevalence of Lynch syndrome, associated cancer risks and pathogenicity of several variants in the Icelandic population. We use colorectal cancer samples from 1,182 patients diagnosed between 2000–2009. One-hundred and thirty-two (11.2%) tumours are mismatch repair deficient per immunohistochemistry. Twenty-one (1.8%) have Lynch syndrome while 106 (9.0%) have somatic hypermethylation or mutations in the mismatch repair genes. The population prevalence of Lynch syndrome is 0.442%. We discover a translocation disrupting MLH1 and three mutations in MSH6 and PMS2 that increase endometrial, colorectal, brain and ovarian cancer risk. We find thirteen mismatch repair variants of uncertain significance that are not associated with cancer risk. We find that founder mutations in MSH6 and PMS2 prevail in Iceland unlike most other populations. PMID:28466842
Montazer Haghighi, Mahdi; Radpour, Ramin; Aghajani, Katayoun; Zali, Narges; Molaei, Mahsa; Zali, Mohammad Reza
2009-08-01
Hereditary nonpolyposis colorectal cancer (HNPCC) is the most common cause of early onset hereditary colorectal cancer. In the majority of HNPCC families, microsatellite instability (MSI) and germline mutation in one of the DNA mismatch repair (MMR) genes are found. The entire coding sequence of MMR genes (MLH1, MLH2, MLH6, and PMS2) was analyzed using direct sequencing. Also, tumor tests were done as MSI and immunohistochemistry testing. We were able to find three novel MLH1 and one novel PMS2 germline mutations in three Iranian HNPCC patients. The first was a transversion mutation c.346A>C (T116P) and happened in the highly conserved HATPase-c region of MLH1 protein. The second was a transversion mutation c.736A>T (I246L), which caused an amino acid change of isoleucine to leucine. The third mutation (c.2145,6 delTG) was frameshift and resulted in an immature stop codon in five codons downstream. All of these three mutations were detected in the MLH1 gene. The other mutation was a transition mutation, c.676G>A (G207E), which has been found in exon six of the PMS2 gene and caused an amino acid change of glycine to glutamic acid. MSI assay revealed high instability in microsatellite for two patients and microsatellite stable for one patient. In all patients, an abnormal expression of the MMR proteins in HNPCC was related to the above novel mutations.
The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium
International Nuclear Information System (INIS)
Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.
1984-01-01
The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium
A design of scintillator tiles read out by surface-mounted SiPMs for a future hadron calorimeter
Energy Technology Data Exchange (ETDEWEB)
Liu, Yong; Bauss, Bruno; Buescher, Volker; Caudron, Julien; Chau, Phi; Degele, Reinhold; Geib, Karl-Heinrich; Masetti, Lucia; Schaefer, Ulrich; Tapprogge, Stefan; Wanke, Rainer [Institut fuer Physik and PRISMA Detector Lab, Johannes Gutenberg-Universitaet Mainz (Germany)
2015-07-01
Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten millions of channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve high response to Minimum Ionizing Particles (MIPs) and also good areal uniformity. Cosmic-ray measurements confirms high 1-MIP response for scintillator tiles with an optimized cavity design. Uniformity measurements by scanning the tile area using focused electrons from a beta source show excellent response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.
Energy Doubler cryoloop temperature monitor system
International Nuclear Information System (INIS)
Pucci, G.; Howard, D.
1981-10-01
The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control
Hanger-type laundry monitor system
International Nuclear Information System (INIS)
Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro
1987-01-01
Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)
Storage monitoring systems for the year 2000
International Nuclear Information System (INIS)
Nilsen, C.; Pollock, R.
1997-01-01
In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000
Performance Monitoring Applied to System Supervision
Directory of Open Access Journals (Sweden)
Bertille Somon
2017-07-01
Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.
Plant-wide integrated equipment monitoring and analysis system
International Nuclear Information System (INIS)
Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.
2004-01-01
A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)
International Nuclear Information System (INIS)
Livingston, R.R.
1992-01-01
Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)
On predicting monitoring system effectiveness
Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo
2015-03-01
While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.
Monitoring in educational development projects : the development of a monitoring system
Plomp, T.; Huijsman, Hari; Kluyfhout, Eric
1992-01-01
Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with
Ghabrous Larrea, C
2009-01-01
As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...
Remote supervision of GIS monitoring system
Energy Technology Data Exchange (ETDEWEB)
Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)
2007-07-01
Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.
van der Klift, Heleen M; Tops, Carli M; Hes, Frederik J; Devilee, Peter; Wijnen, Juul T
2012-07-01
Heterozygous germline mutations in the mismatch repair gene PMS2 predispose carriers for Lynch syndrome, an autosomal dominant predisposition to cancer. Here, we present a LINE-1-mediated retrotranspositional insertion in PMS2 as a novel mutation type for Lynch syndrome. This insertion, detected with Southern blot analysis in the genomic DNA of the patient, is characterized as a 2.2 kb long 5' truncated SVA_F element. The insertion is not detectable by current diagnostic testing limited to MLPA and direct Sanger sequencing on genomic DNA. The molecular nature of this insertion could only be resolved in RNA from cultured lymphocytes in which nonsense-mediated RNA decay was inhibited. Our report illustrates the technical problems encountered in the detection of this mutation type. Especially large heterozygous insertions will remain unnoticed because of preferential amplification of the smaller wild-type allele in genomic DNA, and are probably underreported in the mutation spectra of autosomal dominant disorders. © 2012 Wiley Periodicals, Inc.
System of message for gamma-radiation monitor
International Nuclear Information System (INIS)
Bolic, M.D.; Koturovic, A.M.
2001-01-01
Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru
Stack Monitoring System At PUSPATI TRIGA Reactor
International Nuclear Information System (INIS)
Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin
2014-01-01
This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)
Digital radiation monitor system
International Nuclear Information System (INIS)
Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan
2003-01-01
The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet
Wei, Jo-Ting; Chang, Yeun Wen; Zhang, Xiaoxiang; Wu, Hsin-Hung
2017-01-01
For firms implementing TQM, there is a need to redesign performance measurement systems (PMS). Innovated PMS ought to have measurement diversity in their structure with considering the spirit of TQM and emphasize the congruence of goals between employees and firms by adding the viewpoint of person-organisation fit (P-O fit). This paper adopts structural equation modeling (SEM) to examine Taiwanese manufacturing firms to study the association between the P-O fit of PMS and the implementation o...
Instrumentation for Power System Disturbance Monitoring, Data ...
African Journals Online (AJOL)
In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...
Erbay, Celal; Carreon-Bautista, Salvador; Sanchez-Sinencio, Edgar; Han, Arum
2014-12-02
Microbial fuel cell (MFC) that can directly generate electricity from organic waste or biomass is a promising renewable and clean technology. However, low power and low voltage output of MFCs typically do not allow directly operating most electrical applications, whether it is supplementing electricity to wastewater treatment plants or for powering autonomous wireless sensor networks. Power management systems (PMSs) can overcome this limitation by boosting the MFC output voltage and managing the power for maximum efficiency. We present a monolithic low-power-consuming PMS integrated circuit (IC) chip capable of dynamic maximum power point tracking (MPPT) to maximize the extracted power from MFCs, regardless of the power and voltage fluctuations from MFCs over time. The proposed PMS continuously detects the maximum power point (MPP) of the MFC and matches the load impedance of the PMS for maximum efficiency. The system also operates autonomously by directly drawing power from the MFC itself without any external power. The overall system efficiency, defined as the ratio between input energy from the MFC and output energy stored into the supercapacitor of the PMS, was 30%. As a demonstration, the PMS connected to a 240 mL two-chamber MFC (generating 0.4 V and 512 μW at MPP) successfully powered a wireless temperature sensor that requires a voltage of 2.5 V and consumes power of 85 mW each time it transmit the sensor data, and successfully transmitted a sensor reading every 7.5 min. The PMS also efficiently managed the power output of a lower-power producing MFC, demonstrating that the PMS works efficiently at various MFC power output level.
A unique radiation area monitoring system
International Nuclear Information System (INIS)
Murphy, P.C.; Allen, G.C.
1978-01-01
The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area
Remote Arrhythmia Monitoring System Developed
York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.
2004-01-01
Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.
Drinking-water monitoring systems
International Nuclear Information System (INIS)
1994-01-01
A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission
Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection
International Nuclear Information System (INIS)
Schuette, A.; Blaesig, H.
1982-01-01
The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)
Car monitoring information systems
Directory of Open Access Journals (Sweden)
Alica KALAŠOVÁ
2008-01-01
Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.
Directory of Open Access Journals (Sweden)
Pramadya Alfitra
2012-03-01
Full Text Available 800x600 Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Torbangun (Coleus amboinicus Lour is one of Labiatae family containing a lot of micronutrients and active components. The plant is used as traditional medicine for relieving premenstrual syndromes (PMS. Based on the results of previous studies, a capsule containing 750 mg of dried Torbangun leaves can relieve PMS as well as commercial herbal, and better than placebo. Capsule supplement form seems less acceptable because it tastes like taking a drug. Therefore, it requires development for Torbangun supplement product in other forms, and one of them is a supplement drink. The study is aimed to formulate a supplement drink from Torbangun leaves as the basic ingredients. Supplement drink formulation is made in trial and error by combining extract of torbangun leaves, sucrose, and lemon, obtaining three formulas: DT1 contains 10 g extract of torbangun leaves and 16 g sucrose, DT2 contains 10 g extract of torbangun leaves, 2 g lemon, 22 g sucrose, and DT3 contains 10 g extract of torbangun leaves, 4 g lemon, and 28 g sucrose. These formulas are then tested by organoleptic, physical, and chemical. The results show that the formula DT3 has the highest average score. Blanching treatment improves organoleptic properties of supplement drinks. Mean scores in color, aroma, and taste of the blanched supplement drink are different (p Key words: Torbangun leaves, premenstrual syndrome, supplement drink, blanching.
Remote container monitoring and surveillance systems
International Nuclear Information System (INIS)
Resnik, W.M.; Kadner, S.P.
1995-01-01
Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed
Critical function monitoring system algorithm development
International Nuclear Information System (INIS)
Harmon, D.L.
1984-01-01
Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms
Kues, Johanna N; Janda, Carolyn; Kleinstäuber, Maria; Weise, Cornelia
2016-10-01
With 75% of women of reproductive age affected, premenstrual symptoms are very common, ranging from emotional and cognitive to physical symptoms. Premenstrual Syndrome and Premenstrual Dysphoric Disorder can lead to substantial functional interference and psychological distress comparable to that of dysthymic disorders. The assessment of this impact is required as a part of the diagnostic procedure in the DSM-5. In the absence of a specific measure, the authors developed the PMS-Impact Questionnaire. A sample of 101 women reporting severe premenstrual complaints was assessed with the twenty-two items in the questionnaire during their premenstrual phase in an ongoing intervention study at the Philipps-University Marburg from August 2013 until January 2015. An exploratory factor analysis revealed a two-factor solution (labeled Psychological Impact and Functional Impact) with 18 items. A Cronbach's alpha of 0.90 for Psychological Impact and of 0.90 for Functional Impact indicated good reliability. Convergent construct validity was demonstrated by moderate to high correlations with the Pain Disability Index. Low correlations with the Big Five Inventory-10 indicated good divergent validity. The PMS-Impact Questionnaire was found to be a valid, reliable, and an economic measure to assess the impact of premenstrual symptoms. In future research, cross validations and confirmatory factor analyses should be conducted.
Centralized environmental radiation monitoring system in JAERI
International Nuclear Information System (INIS)
Katagiri, Hiroshi; Kobayashi, Hideo
1993-03-01
Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)
Distributed intelligent urban environment monitoring system
Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang
2018-02-01
The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion
Visualization System for Monitoring Data Management Systems
Directory of Open Access Journals (Sweden)
Emanuel Pinho
2016-11-01
Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.
Zelga, Piotr; Przybyłowska-Sygut, Karolina; Zelga, Marta; Dziki, Adam; Majsterek, Ireneusz
2018-04-01
Colorectal cancer (CRC) is one of the most common cancers worldwide. DNA mismatch repair (MMR) is an evolutionarily conserved process that corrects mismatches generated during DNA replication. MMR defects were found to be associated with hereditary non-polyposis colorectal cancer (HNPCC) and a subset of sporadic colon cancers. The inheritance of common variations in MMR genes may influences individual susceptibility to the development of colorectal cancer. The purpose of the study was to evaluate the association between gene polymorphisms Glu39Gly (c.116G > A) of MSH6 gene and IVS1-1121C > T of PMS2 gene and sporadic colorectal cancer risk, in a case-control study comprising 200 patients and 200 controls origination from polish population. DNA was isolated from peripheral blood lymphocytes of enrolled patients, and gene polymorphisms were analysed by restriction fragment length polymorphism-polymerase chain reaction (RFLP-PCR) for MSH6 and TaqMan for PMS2. G/A variant of Glu39Gly (c.116G > A) genotype was associated with an increased risk of colorectal cancer (OR 1,65 95%CI:1,01-2,69 p = 0.44). Presence of A allele was also significantly higher in patient with CRC (OR 1,57 95% CI: 1,04-2,38 p = 0.032). Prevalence of this genotype was also markedly higher in females and patients above 60 years in CRC group (OR 2.25 95%CI: 1.22-4.14 p = 0.0098 and OR 2.74 95% CI: 1.27-5.93 p = 0.0097 respectively). None of such correlations was observed for genotype variants of IVS1-1121C > T PMS2. In conclusion, our data suggests thatMSH6 Glu39Gly polymorphism is associated with the risk of developing sporadic colorectal cancer in polish population. Linkage to the female gender, onset above 60 years old and further increase of risk when combined with wild-type allele of PMS2 IVS1-1121C > T polymorphism indicates defective mismatch repair system.
Online NPP monitoring with neuro-expert system
International Nuclear Information System (INIS)
Nabeshima, K.
2002-01-01
This study present a hybrid monitoring system for nuclear power plant utilizing neural networks and a rule-based expert system. The whole monitoring system including a data acquisition system and the advisory displays has been tested by an on-line simulator of pressurized water reactor. From the testing results, it was shown that the neural network in the monitoring system successfully modeled the plant dynamics and detected the symptoms of anomalies earlier than the conventional alarm system. The expert system also worked satisfactorily in diagnosing and displaying the system status by using the outputs of neural networks and a priori knowledge base
Area monitoring intelligent system - SIMA
International Nuclear Information System (INIS)
Bhoem, P.; Hisas, F.; Gelardi, G.
1990-01-01
The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es
Computerized plutonium laboratory-stack monitoring system
International Nuclear Information System (INIS)
Stafford, R.G.; DeVore, R.K.
1977-01-01
The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas
Girelli Zubani, Giulia; Zivojnovic, Marija; De Smet, Annie; Albagli-Curiel, Olivier; Huetz, François; Weill, Jean-Claude; Reynaud, Claude-Agnès; Storck, Sébastien
2017-04-03
During somatic hypermutation (SHM) of immunoglobulin genes, uracils introduced by activation-induced cytidine deaminase are processed by uracil-DNA glycosylase (UNG) and mismatch repair (MMR) pathways to generate mutations at G-C and A-T base pairs, respectively. Paradoxically, the MMR-nicking complex Pms2/Mlh1 is apparently dispensable for A-T mutagenesis. Thus, how detection of U:G mismatches is translated into the single-strand nick required for error-prone synthesis is an open question. One model proposed that UNG could cooperate with MMR by excising a second uracil in the vicinity of the U:G mismatch, but it failed to explain the low impact of UNG inactivation on A-T mutagenesis. In this study, we show that uracils generated in the G1 phase in B cells can generate equal proportions of A-T and G-C mutations, which suggests that UNG and MMR can operate within the same time frame during SHM. Furthermore, we show that Ung -/- Pms2 -/- mice display a 50% reduction in mutations at A-T base pairs and that most remaining mutations at A-T bases depend on two additional uracil glycosylases, thymine-DNA glycosylase and SMUG1. These results demonstrate that Pms2/Mlh1 and multiple uracil glycosylases act jointly, each one with a distinct strand bias, to enlarge the immunoglobulin gene mutation spectrum from G-C to A-T bases. © 2017 Girelli Zubani et al.
Upgrade of the LHCb ECAL monitoring system
Guz, Yu
2015-01-01
The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.
Suerink, Manon; van der Klift, Heleen M.; ten Broeke, Sanne W.; Dekkers, Olaf M.; Bernstein, Inge; Capella Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G. W.; Menko, Fred H.; Lindblom, Annika; Mensenkamp, Arjen; Moller, Pal; van Os, Theo A.; Rahner, Nils; Redeker, Bert J. W.; Olderode, Maran; Spruijt, Liesbeth; Vos, Yvonne J.; Wagner, Anja; Morreau, Hans; Hes, Frederik J.; Vasen, Hans F. A.; Tops, Carli M.; Wijnen, Juul T.; Nielsen, Maartje
Purpose: Lynch syndrome (LS), a heritable disorder with an increased risk of primarily colorectal cancer (CRC) and endometrial cancer (EC), can be caused by mutations in the PMS2 gene. We wished to establish whether genotype and/or parent-of-origin effects (POE) explain (part of) the reported
Suerink, Manon; van der Klift, Heleen M; Ten Broeke, Sanne W; Dekkers, Olaf M; Bernstein, Inge; Capellá Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G W; Menko, Fred H; Lindblom, Annika; Mensenkamp, Arjen; Moller, Pal; van Os, Theo A; Rahner, Nils; Redeker, Bert J W; Olderode, Maran; Spruijt, Liesbeth; Vos, Yvonne J; Wagner, Anja; Morreau, Hans; Hes, Frederik J; Vasen, Hans F A; Tops, Carli M; Wijnen, Juul T; Nielsen, Maartje
PURPOSE: Lynch syndrome (LS), a heritable disorder with an increased risk of primarily colorectal cancer (CRC) and endometrial cancer (EC), can be caused by mutations in the PMS2 gene. We wished to establish whether genotype and/or parent-of-origin effects (POE) explain (part of) the reported
Suerink, Manon; van der Klift, Heleen M.; ten Broeke, Sanne W.; Dekkers, Olaf M.; Bernstein, Inge; Capellá Munar, Gabriel; Gomez Garcia, Encarna; Hoogerbrugge, Nicoline; Letteboer, Tom G. W.; Menko, Fred H.; Lindblom, Annika; Mensenkamp, Arjen; Moller, Pal; van Os, Theo A.; Rahner, Nils; Redeker, Bert J. W.; Olderode-Berends, M. J. W.; Olderode, Maran; Spruijt, Liesbeth; Vos, Yvonne J.; Wagner, Anja; Morreau, Hans; Hes, Frederik J.; Vasen, Hans F. A.; Tops, Carli M.; Wijnen, Juul T.; Nielsen, Maartje
2016-01-01
Lynch syndrome (LS), a heritable disorder with an increased risk of primarily colorectal cancer (CRC) and endometrial cancer (EC), can be caused by mutations in the PMS2 gene. We wished to establish whether genotype and/or parent-of-origin effects (POE) explain (part of) the reported variability in
Suerink, M.; Klift, H.M. van der; Broeke, S.W. ten; Dekkers, O.M.; Bernstein, I.; Capella Munar, G.; Garcia, E.; Hoogerbrugge, N.; Letteboer, T.G.; Menko, F.H.; Lindblom, A.; Mensenkamp, A.; Moller, P.; Os, T.A. van; Rahner, N.; Redeker, B.J.; Olderode-Berends, M.J.; Spruijt, L.; Vos, Y.J.; Wagner, A.; Morreau, H.; Hes, F.J.; Vasen, H.F.A.; Tops, C.M.; Wijnen, J.T.; Nielsen, M.
2016-01-01
PURPOSE: Lynch syndrome (LS), a heritable disorder with an increased risk of primarily colorectal cancer (CRC) and endometrial cancer (EC), can be caused by mutations in the PMS2 gene. We wished to establish whether genotype and/or parent-of-origin effects (POE) explain (part of) the reported
Centralized environmental radiation monitoring system in JAERI
International Nuclear Information System (INIS)
Katagiri, H.; Kobalyashi, H.
1993-01-01
JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles
Life Support Systems: Environmental Monitoring
National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...
Acoustic emission leak monitoring system LMS-96
International Nuclear Information System (INIS)
Liska, J.; Cvrcek, M.; Mueller, L.
1997-01-01
On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)
Vogt, Julia; Wernstedt, Annekatrin; Ripperger, Tim; Pabst, Brigitte; Zschocke, Johannes; Kratz, Christian; Wimmer, Katharina
2016-11-01
Biallelic PMS2 mutations are responsible for more than half of all cases of constitutional mismatch repair deficiency (CMMRD), a recessively inherited childhood cancer predisposition syndrome. The mismatch repair gene PMS2 is partly embedded within one copy of an inverted 100-kb low-copy repeat (LCR) on 7p22.1. In an individual with CMMRD syndrome, PMS2 was found to be homozygously inactivated by a complex chromosomal rearrangement, which separates the 5'-part from the 3'-part of the gene. The rearrangement involves sequences of the inverted 100-kb LCR and a human endogenous retrovirus element and may be associated with an inversion that is indistinguishable from the known inversion polymorphism affecting the ~0.7-Mb sequence intervening the LCR. Its formation is best explained by a replication-based mechanism (RBM) such as fork stalling and template switching/microhomology-mediated break-induced replication (FoSTeS/MMBIR). This finding supports the hypothesis that the inverted LCR can not only facilitate the formation of the non-allelic homologous recombination-mediated inversion polymorphism but it also promotes the occurrence of more complex rearrangements that can be associated with a large inversion, as well, but are mediated by a RBM. This further suggests that among the inversion polymorphism on 7p22.1, more complex rearrangements might be hidden. Furthermore, as the locus is embedded in a common fragile site (CFS) region, this rearrangement also supports the recently raised hypothesis that CFS sequence motifs may facilitate replication-based rearrangement mechanisms.
Directory of Open Access Journals (Sweden)
Mazarina Devi
2013-07-01
Full Text Available ABSTRACT Background: Torbangun leaves (Coleus ambonicus Lour is one of type of species from Labiatae family which contains a lot of micronutrient and active element which have been examined as beneficial for human health and quality of life. The plants containing iridoid and flavonoid as well as phytochemical which deal with reproduction hormone is applicable to traditional medication toward PMS cases. Methods: The present study was aimed to assess the efficacy of CAL leaves in the management of PMS. An experimental clinical trial was conducted in 35 teenagers with PMS. Three intervention groups were defined: CAL leaves; commercial preparation; and placebo. Participants were followed-up individually for 1 month. Result: The results showed average menarche occurred around age 13 years, with menstruation lasting 5 days. During each successive treatment cycle, participants experienced a lower pain intensity score. Chi Square test, after adjusting each cycle for baseline pain, treatment compliance and other variables, showed that the group receiving CAL extract had significantly reduced pain intensity (p<0.05 compared with commercial preparation and placebo. Conclusion: The torbangun leaves supplement can be used as treatment to relief symptoms of the premenstrual syndrome. [Penel Gizi Makan 2010, 33(2:180-194] Keywords: Torbangun leaves (Coleus amboinicus Lour, pre-menstrual syndrome (PMS, teenage girls
Portable water quality monitoring system
Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.
2017-09-01
Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.
IMPLEMENTATION OF PROPERTY MANAGEMENT SYSTEM IN HOTEL INDUSTRY
Krželj-Čolović, Zorica; Cerović, Zdenko
2013-01-01
Information and Communication Technologies (ICT) influences the development tourism on globally, and its development has changed the practice of business. Any reference ICT in the hotel industry necessarily begins the concept of Property Management System (PMS). PMS as an essential component for hotel management provides tools as are necessary hotel staff in performing daily operations of the reservation, the accommodation capacities management, accounting, etc. This software supports all bas...
Real-time performance monitoring and management system
Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA
2007-06-19
A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.
Ramchander, N C; Ryan, N A J; Crosbie, E J; Evans, D G
2017-04-05
Constitutional mismatch repair deficiency syndrome results from bi-allelic inheritance of mutations affecting the key DNA mismatch repair genes: MLH1, MSH2, MSH6 or PMS2. Individuals with bi-allelic mutations have a dysfunctional mismatch repair system from birth; as a result, constitutional mismatch repair deficiency syndrome is characterised by early onset malignancies. Fewer than 150 cases have been reported in the literature over the past 20 years. This is the first report of the founder PMS2 mutation - NM_000535.5:c.1500del (p.Val501TrpfsTer94) in exon 11 and its associated cancers in this family. The proband is 30 years old and is alive today. She is of Pakistani ethnic origin and a product of consanguinity. She initially presented aged 24 with painless bleeding per-rectum from colorectal polyps and was referred to clinical genetics. Clinical examination revealed two café-au-lait lesions, lichen planus, and a dermoid cyst. Her sister had been diagnosed in childhood with an aggressive brain tumour followed by colorectal cancer. During follow up, the proband developed 37 colorectal adenomatous polyps, synchronous ovarian and endometrial adenocarcinomas, and ultimately a metachronous gastric adenocarcinoma. DNA sequencing of peripheral lymphocytes revealed a bi-allelic inheritance of the PMS2 mutation NM_000535.5:c.1500del (p.Val501TrpfsTer94) in exon 11. Ovarian tumour tissue demonstrated low microsatellite instability. To date, she has had a total abdominal hysterectomy, bilateral salpingo-oophorectomy, and a total gastrectomy. Aspirin and oestrogen-only hormone replacement therapy provide some chemoprophylaxis and manage postmenopausal symptoms, respectively. An 18-monthly colonoscopy surveillance programme has led to the excision of three high-grade dysplastic colorectal tubular adenomatous polyps. The proband's family pedigree displays multiple relatives with cancers including a likely case of 'true' Turcot syndrome. Constitutional mismatch repair
Uranium concentration monitor manual: 2300 system
International Nuclear Information System (INIS)
Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.
1985-04-01
This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs
Wouters, Marc; Wilderom, Celeste P.M.
2008-01-01
This paper reports on a developmental approach to performance-measurement systems (PMS). In particular, we look at characteristics of a development process that result in the PMS being perceived by employees as enabling of their work, rather than as primarily a control device for use by senior
Development of a Gamma Spectrometer using a Large NaI Scintillator and SiPMs
International Nuclear Information System (INIS)
Kim, Chankyu; Yoo, Hyunjun; Kim, Yewon and others
2014-01-01
A typical scintillation gamma spectrometer is composed of a NaI(Tl) scintillation crystal and a PM tube. From last years, a Silicon Photomultiplier (SiPM) is being developed and expanding its application area as a substitute of PM tube due to its advantages like low operating voltage, small volume, and cheap production cost, MR compatibility. This approach could make gamma spectrometer smaller, cheaper, easier to use, and these advantage are quite suitable to original purpose of scintillation gamma spectrometer. Gamma spectrometry and gamma spectrometer is used to analyze gamma source in nuclear science, geochemistry, and astrophysics. In this research, gamma spectrometer which uses SiPMs instead of PM tube is proposed. The proposed gamma spectrometer has advantages of low cost, small volume, low operation voltage; but it has disadvantages of performances. To reduce this loss in performances, a light guide of effective structure is required. (Material, reflection type, tapering angle) For design of the light guide, DETECT simulation was performed. And through DETECT simulation, the characteristics of light guide could be prospected. Actual light guide was manufactured on the basis of this simulation result. Using the light guide, gamma spectrometer system was composed and tested. In the test result, gamma spectrometer using SiPM shows degraded energy resolution. The reason of this degradation is being analyzed and the test system is under modification
Standard-D hydrogen monitoring system, system design description
International Nuclear Information System (INIS)
Schneider, T.C.
1996-01-01
During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS
Radiation monitoring system based on EPICS
International Nuclear Information System (INIS)
Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang
2008-01-01
Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)
FFTF fission gas monitor computer system
International Nuclear Information System (INIS)
Hubbard, J.A.
1987-01-01
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports
Marinovic-Terzic, Ivana; Yoshioka-Yamashita, Atsuko; Shimodaira, Hideki; Avdievich, Elena; Hunton, Irina C.; Kolodner, Richard D.; Edelmann, Winfried; Wang, Jean Y. J.
2008-01-01
Mismatch repair (MMR) corrects replication errors during DNA synthesis. The mammalian MMR proteins also activate cell cycle checkpoints and apoptosis in response to persistent DNA damage. MMR-deficient cells are resistant to cisplatin, a DNA cross-linking agent used in chemotherapy, because of impaired activation of apoptotic pathways. It is shown that postmeiotic segregation 2 (PMS2), an MMR protein, is required for cisplatin-induced activation of p73, a member of the p53 family of transcrip...
Moisture monitoring and control system engineering study
International Nuclear Information System (INIS)
Carpenter, K.E.; Fadeff, J.G.
1995-01-01
During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria
The SSRL injector beam position monitoring systems
International Nuclear Information System (INIS)
Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.
1991-01-01
The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR
Ulysses spacecraft control and monitoring system
Hamer, P. A.; Snowden, P. J.
1991-01-01
The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.
2010-04-01
... HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.101 Purpose. The purpose of this part is to implement... highway pavement of Federal-aid highways (PMS), bridges on and off Federal-aid highways (BMS), highway...
Raskin, G A; Ianus, G A; Kornilov, A V; Orlova, R V; Petrov, S V; Protasova, A É; Pozharisskiĭ, K M; Imianitov, E N
2014-01-01
Adenocarcinoma of the colon in 10-20% is associated with microsatellite instability, which can occur both in sporadic cancers and in hereditary nonpolyposis colon cancer. Our analysis of 195 cases of adenocarcinoma of the colon showed that microsatellite instability (MSI-H) was found only in 1.5% of patients. Subsequent choice of patients with suspected hereditary Lynch syndrome led to the identification of additional 17 patients with microsatellite instability. They passed an analysis of genes of repair system of unpaired nucleotides of DNA. The study showed that immunohistochemical staining of MSH2, MSH6, MLH1, PMS2 could effectively conduct a preliminary screening of the Lynch syndrome but was unable to divide cases of sporadic and hereditary MSI-H colon cancer.
National Satellite Forest Monitoring systems for REDD+
Jonckheere, I. G.
2012-12-01
Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows
Mosset, J.-B.; Stoykov, A.; Greuter, U.; Gromov, A.; Hildebrandt, M.; Panzner, T.; Schlumpf, N.
2017-02-01
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on a ZnS:6LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current 3He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
Efficacy of Vitex agnus castus L. extract Ze 440 in patients with pre-menstrual syndrome (PMS).
Berger, D; Schaffner, W; Schrader, E; Meier, B; Brattström, A
2000-11-01
In a prospective, multicentre trial the efficacy of an Vitex agnus castus L extract Ze 440 was investigated in 50 patients with pre-menstrual syndrome (PMS). The patients were treated daily with one tablet (20 mg native extract) during three menstrual cycles. 43 patients completed the study protocol which encompassed 8 menstrual cycles (2 baseline, 3 treatment and 3 post-treatment). 13/43 patients were receiving concomitant oral contraceptives. 6 patients did not complete the study for reasons not related to study medication, and one patient complained of fatigue possibly related to study medication. All evaluated patients took at least 85% of the prescribed medication. The main effect parameter was the validated Moos' menstrual distress questionnaire (MMDQ), and secondary parameters were a visual analogue scale (VAS; self-assessment) and a global impression scale (GI, self-assessment). The study population was homogenous in age (31.3+/-7.7 years) weight (58.9+/-6.9 kg) and cycle length (28.4+/-0.3 d). The diagnosis was according to DMS-III. At the end of the study, PMS-related symptoms were reduced by treatment. There was a significant score reduction (42.5%) of the MMDQ as the main effect parameter (pVitex agnus-castus extract Ze 440, as indicated by clear improvement in the main effect parameter during treatment and the gradual return after cessation of treatment. The main response to treatment seems related to symptomatic relief rather than to the duration of the syndrome.
Automated Vehicle Monitoring System
Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi
2014-01-01
An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.
Current status of technology development on remote monitoring system
International Nuclear Information System (INIS)
Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.
1997-03-01
IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs
Competing failure analysis in phased-mission systems with functional dependence in one of phases
International Nuclear Information System (INIS)
Wang, Chaonan; Xing, Liudong; Levitin, Gregory
2012-01-01
This paper proposes an algorithm for the reliability analysis of non-repairable phased-mission systems (PMS) subject to competing failure propagation and isolation effects. A failure originating from a system component which causes extensive damage to other system components is a propagated failure. When the propagated failure affects all the system components, causing the entire system failure, a propagated failure with global effect (PFGE) is said to occur. However, the failure propagation can be isolated in systems subject to functional dependence (FDEP) behavior, where the failure of a component (referred to as trigger component) causes some other components (referred to as dependent components) to become inaccessible or unusable (isolated from the system), and thus further failures from these dependent components have no effect on the system failure behavior. On the other hand, if any PFGE from dependent components occurs before the trigger failure, the failure propagation effect takes place, causing the overall system failure. In summary, there are two distinct consequences of a PFGE due to the competition between the failure isolation and failure propagation effects in the time domain. Existing works on such competing failures focus only on single-phase systems. However, many real-world systems are phased-mission systems (PMS), which involve multiple, consecutive and non-overlapping phases of operations or tasks. Consideration of competing failures for PMS is a challenging and difficult task because PMS exhibit dynamics in the system configuration and component behavior as well as statistical dependencies across phases for a given component. This paper proposes a combinatorial method to address the competing failure effects in the reliability analysis of binary non-repairable PMS. The proposed method is verified using a Markov-based method through a numerical example. Different from the Markov-based approach that is limited to exponential distribution, the
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G.; Salapura, Valentina
2012-07-24
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.
An automated neutron monitor maintenance system
International Nuclear Information System (INIS)
Moore, F.S.; Griffin, J.C.; Odell, D.M.C.
1996-01-01
Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications
Integrated environmental monitoring and information system
International Nuclear Information System (INIS)
Klinda, J.; Lieskovska, Z.
1998-01-01
The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included
Remote Maintenance Monitoring System -
Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...
Structure health monitoring system using internet and database technologies
International Nuclear Information System (INIS)
Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok
2003-01-01
Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.
Structural health monitoring system using internet and database technologies
Energy Technology Data Exchange (ETDEWEB)
Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)
2003-07-01
Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.
Structure health monitoring system using internet and database technologies
Energy Technology Data Exchange (ETDEWEB)
Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)
2003-05-15
Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.
Structural health monitoring system using internet and database technologies
International Nuclear Information System (INIS)
Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok
2003-01-01
Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.
International Nuclear Information System (INIS)
Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.
1987-01-01
In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)
OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS
Directory of Open Access Journals (Sweden)
Inna Pivovarova
2016-09-01
Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.
Modification of GNPS environment radiation monitoring network system
International Nuclear Information System (INIS)
Jiang Lili; Cao Chunsheng
1999-01-01
GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition
MDOT Pavement Management System : Prediction Models and Feedback System
2000-10-01
As a primary component of a Pavement Management System (PMS), prediction models are crucial for one or more of the following analyses: : maintenance planning, budgeting, life-cycle analysis, multi-year optimization of maintenance works program, and a...
Project W-420 stack monitoring system upgrades
International Nuclear Information System (INIS)
CARPENTER, K.E.
1999-01-01
This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420
Reliability of operating WWER monitoring systems
International Nuclear Information System (INIS)
Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.
1996-01-01
The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs
Reliability of operating WWER monitoring systems
Energy Technology Data Exchange (ETDEWEB)
Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.
1997-12-31
The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.
Wang, Wanshun; Chen, Zhuo; Li, Xiuwen
2018-03-01
The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.
International Nuclear Information System (INIS)
Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo
2014-01-01
The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)
Mechatronics in design of monitoring and diagnostic systems
Energy Technology Data Exchange (ETDEWEB)
Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)
2003-07-01
Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)
Monitoring the CMS Data Acquisition System
Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.
2010-01-01
The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...
Hybrid Wireless Hull Monitoring System for Naval Combat Vessels
2010-03-01
Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system
Radiation monitoring system in medical facilities
International Nuclear Information System (INIS)
Matsuno, Kiyoshi
1981-01-01
(1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)
Bulk laundry monitoring system
International Nuclear Information System (INIS)
Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.
2012-01-01
Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement
Apparatus, System, And Method For Roadway Monitoring
Claudel, Christian G.
2015-06-02
An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.
Apparatus, System, And Method For Roadway Monitoring
Claudel, Christian G.
2015-01-01
An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.
International Nuclear Information System (INIS)
Schneider, S.; Lucero, R.; Glidewell, D.
1997-01-01
The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs
Instrument failure monitoring in nuclear power systems
International Nuclear Information System (INIS)
Tylee, J.L.
1982-01-01
Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data
A primary mirror metrology system for the GMT
Rakich, A.
2016-07-01
The Giant Magellan Telescope (GMT)1 is a 25 m "doubly segmented" telescope composed of seven 8.4 m "unit Gregorian telescopes", on a common mount. Each primary and secondary mirror segment will ideally lie on the geometrical surface of the corresponding rotationally symmetrical full aperture optical element. Therefore, each primary and conjugated secondary mirror segment will feed a common instrument interface, their focal planes co-aligned and cophased. First light with a subset of four unit telescopes is currently scheduled for 2022. The project is currently considering an important aspect of the assembly, integration and verification (AIV) phase of the project. This paper will discuss a dedicated system to directly characterize the on-sky performance of the M1 segments, independently of the M2 subsystem. A Primary Mirror Metrology System (PMS) is proposed. The main purpose of this system will be to he4lp determine the rotation axis of an instrument rotator (the Gregorian Instrument Rotator or GIR in this case) and then to characterize the deflections and deformations of the M1 segments with respect to this axis as a function of gravity and temperature. The metrology system will incorporate a small (180 mm diameter largest element) prime focus corrector (PFC) that simultaneously feeds a risk reduction during AIV; it allows an on-sky characterization of the primary mirror segments and cells, without the complications of other optical elements. The PMS enables a very useful alignment strategy that constrains each primary mirror segments' optical axes to follow the GIR axis to within a few arc seconds. An additional attractive feature of the incorporation of the PMS into the AIV plan, is that it allows first on-sky telescope operations to occur with a system of considerably less optical and control complexity than the final doubly segmented Gregorian telescope configuration. This paper first discusses the strategic rationale for a PMS. Next the system itself is
Monitoring support system for nuclear power plant
International Nuclear Information System (INIS)
Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki
1996-01-01
The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)
Beacon-Colss core monitoring system application and benefits
International Nuclear Information System (INIS)
Boyd, W.A.; Yoon, T.Y.
2005-01-01
Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)
Applications for cyber security - System and application monitoring
International Nuclear Information System (INIS)
Marron, J. E.
2006-01-01
Standard network security measures are adequate for defense against external attacks. However, many experts agree that the greater threat is from internal sources. Insiders with malicious intentions can change controller instructions, change alarm thresholds, and issue commands to equipment which can damage equipment and compromise control system integrity. In addition to strict physical security the state of the system must be continually monitored. System and application monitoring goes beyond the capabilities of network security appliances. It will include active processes, operating system services, files, network adapters and IP addresses. The generation of alarms is a crucial feature of system and application monitoring. The alarms should be integrated to avoid the burden on operators of checking multiple locations for security violations. Tools for system and application monitoring include commercial software, free software, and ad-hoc tools that can be easily created. System and application monitoring is part of a 'defense-in-depth' approach to a control network security plan. Layered security measures prevent an individual security measure failure from being exploited into a successful security breach. Alarming of individual failures is essential for rapid isolation and correction of single failures. System and application monitoring is the innermost layer of this defense strategy. (authors)
Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system
International Nuclear Information System (INIS)
Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji
1981-07-01
In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)
Functional food monitoring as part of the new Dutch dietary monitoring system
Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG
2006-01-01
Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based
A radiation monitoring system for nuclear power plants
International Nuclear Information System (INIS)
Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.
1974-01-01
Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)
Monitoring Distributed Real-Time Systems: A Survey and Future Directions
Goodloe, Alwyn E.; Pike, Lee
2010-01-01
Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.
Automated Cryocooler Monitor and Control System Software
Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad
2011-01-01
This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.
Safeguards equipment of the future: Integrated monitoring systems and remote monitoring
International Nuclear Information System (INIS)
Sonnier, C.S.; Johnson, C.S.
1994-01-01
From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors
Delta count-rate monitoring system
International Nuclear Information System (INIS)
Van Etten, D.; Olsen, W.A.
1985-01-01
A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount
Development and application of all-digital monitoring system
International Nuclear Information System (INIS)
Xu Tao; Li Jing; Wang Wei
2014-01-01
All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)
Propose Reactor Control and Monitoring System for RTP
International Nuclear Information System (INIS)
Mohd Sabri Minhat; Izhar Abu Hussin; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha
2011-01-01
Reactor control and monitoring system is a one of the important features used in reactor. The control and monitoring must come together to provide safety, excellent performance and reliable in nuclear reactor technology application. Objectives of this technical paper are to design and propose reactor control system and reactor monitoring system in Research Reactor (RTP) for Reactor Upgrading Project. (author)
Energy Technology Data Exchange (ETDEWEB)
Quan, H.
1996-01-10
This paper summarizes the water monitoring system (WMS) in China applied mainly to surface water and operated within the competence of the Environmental Protection Agency. The WMS consists of a national water monitoring network and a water information system that monitors surface water periodically. The WMS comprises water monitoring stations classified from class 1 to class 4, which are located in 2,222 locations. Stations from class 1 to class 3 are operated by using computers, but class 4 stations are still incapable to use floppy disks to perform information transmission. When an information management system is completed at the China-Japan Friendship Environmental Protection Center being constructed by gratis assistance from the Japanese Government, transmission of water quality data will become possible by means of the cable line system in addition to the table system and the floppy system. The water quality data are published to general people in the forms of Chinese gazette for the environmental conditions, the environment yearbook, and the reports on environmental quality. However, the more important is to publish more publications to make people aware of the actual state of water pollution and have them cooperate in environment preservation. 4 refs., 1 fig.
Beam monitoring system for intense neutron source
International Nuclear Information System (INIS)
Tron, A.M.
2001-01-01
Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)
Quality monitored distributed voting system
Skogmo, David
1997-01-01
A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.
A Prototype Wire Position Monitoring System
International Nuclear Information System (INIS)
Wang, Wei
2010-01-01
The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.
The NASA Carbon Monitoring System
Hurtt, G. C.
2015-12-01
Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder
Directory of Open Access Journals (Sweden)
Jan Zavadsky
2014-07-01
Full Text Available Purpose: The performance management system (PMS is a metasystem over all business processes at the strategic and operational level. Effectiveness of the various management systems depends on many factors. One of them is the consistent definition of each system elements. The main purpose of this study is to explore if the performance management systems of the sample companies is consistent and how companies can create such a system. The consistency in this case is based on the homogenous definition of attributes relating to the performance indicator as a basic element of PMS.Methodology: At the beginning, we used an affinity diagram that helped us to clarify and to group various attributes of performance indicators. The main research results we achieved are through empirical study. The empirical study was carried out in a sample of Slovak companies. The criterion for selection was the existence of the certified management systems according to the ISO 9001. Representativeness of the sample companies was confirmed by application of Pearson´s chi-squared test (χ2 - test due to above standards. Findings: Coming from the review of various literature, we defined four groups of attributes relating to the performance indicator: formal attributes, attributes of target value, informational attributes and attributes of evaluation. The whole set contains 21 attributes. The consistency of PMS is based not on maximum or minimum number of attributes, but on the same type of attributes for each performance indicator used in PMS at both the operational and strategic level. The main findings are: companies use various financial and non-financial indicators at strategic or operational level; companies determine various attributes of performance indicator, but most of the performance indicators are otherwise determined; we identified the common attributes for the whole sample of companies. Practical implications: The research results have got an implication for
DEFF Research Database (Denmark)
Petersen, Martin Nordal
2007-01-01
We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....
Organisational readiness for introducing a performance management system
Directory of Open Access Journals (Sweden)
Michael Ochurub
2012-09-01
Full Text Available Orientation: The successful introduction of performance management systems to the public service requires careful measurement of readiness for change.Research purpose: This study investigated the extent to which employees were ready for change as an indication of whether their organisation was ready to introduce a performance management system (PMS.Motivation for the study: Introducing system changes in organisations depends on positive employee preconditions. There is some debate over whether organisations can facilitate these preconditions. This research investigates change readiness linked to the introduction of a PMS in a public sector organisation. The results add to the growing literature on levels of change readiness.Research design, approach and method: The researchers used a quantitative, questionnairebased design. Because the organisation was large, the researchers used stratified sampling to select a sample from each population stratum. The sample size was 460, which constituted 26% of the total population. They used a South African change readiness questionnaire to elicit employee perceptions and opinions.Main findings: The researchers found that the organisation was not ready to introduce a PMS. The study identified various challenges and key factors that were negatively affecting the introduction of a PMS.Practical/managerial implications: The intention to develop and introduce performance management systems is generally to change the attitudes, values and approaches of managers and employees to the new strategies, processes and plans to improve productivity and performance. However, pre-existing conditions and attitudes could have an effect. It is essential to ensure that organisations are ready to introduce performance management systems and to provide sound change leadership to drive the process effectively. This study contributes to the body of knowledge about the challenges and factors organisations should consider when they
Operational readiness of filtered air discharge monitoring systems
International Nuclear Information System (INIS)
Lafortune, J.F.; Jamieson, T.J.
1993-08-01
An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report
A new type gamma-ray spectrum monitoring system
Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu
2002-01-01
This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels
Smart health monitoring systems: an overview of design and modeling.
Baig, Mirza Mansoor; Gholamhosseini, Hamid
2013-04-01
Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.
Radiation monitoring system based on Internet
International Nuclear Information System (INIS)
Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.
2001-01-01
This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)
Underground ventilation remote monitoring and control system
International Nuclear Information System (INIS)
Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.
1995-01-01
This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system
An on-line adaptive core monitoring system
International Nuclear Information System (INIS)
Verspeek, J.A.; Bruggink, J.C.; Karuza, J.
1997-01-01
An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)
González-Acosta, Maribel; Del Valle, Jesús; Navarro, Matilde; Thompson, Bryony A; Iglesias, Sílvia; Sanjuan, Xavier; Paúles, María José; Padilla, Natàlia; Fernández, Anna; Cuesta, Raquel; Teulé, Àlex; Plotz, Guido; Cadiñanos, Juan; de la Cruz, Xavier; Balaguer, Francesc; Lázaro, Conxi; Pineda, Marta; Capellá, Gabriel
2017-10-01
The clinical spectrum of germline mismatch repair (MMR) gene variants continues increasing, encompassing Lynch syndrome, Constitutional MMR Deficiency (CMMRD), and the recently reported MSH3-associated polyposis. Genetic diagnosis of these hereditary cancer syndromes is often hampered by the presence of variants of unknown significance (VUS) and overlapping phenotypes. Two PMS2 VUS, c.2149G>A (p.V717M) and c.2444C>T (p.S815L), were identified in trans in one individual diagnosed with early-onset colorectal cancer (CRC) who belonged to a family fulfilling clinical criteria for hereditary cancer. Clinico-pathological data, multifactorial likelihood calculations and functional analyses were used to refine their clinical significance. Likelihood analysis based on cosegregation and tumor data classified the c.2444C>T variant as pathogenic, which was supported by impaired MMR activity associated with diminished protein expression in functional assays. Conversely, the c.2149G>A variant displayed MMR proficiency and protein stability. These results, in addition to the conserved PMS2 expression in normal tissues and the absence of germline microsatellite instability (gMSI) in the biallelic carrier ruled out a CMMRD diagnosis. The use of comprehensive strategies, including functional and clinico-pathological information, is mandatory to improve the clinical interpretation of naturally occurring MMR variants. This is critical for appropriate clinical management of cancer syndromes associated to MMR gene mutations.
Monitoring system in reactor dry well
International Nuclear Information System (INIS)
Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.
1991-01-01
A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)
Monitoring system for OpenPBS environment
Energy Technology Data Exchange (ETDEWEB)
Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)
2004-11-21
The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.
Economic analysis of condition monitoring systems for offshore wind turbine sub-systems
DEFF Research Database (Denmark)
May, Allan; MacMillan, David; Thöns, Sebastian
2015-01-01
The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...... and their associated costs has been completed for the blades, drive train, tower and foundation. This paper considers what value can be obtained from integrating these additional systems into the maintenance plan. This is achieved by running simulations on an operations and maintenance model for a wind farm over a 20...
A blade deflection monitoring system
DEFF Research Database (Denmark)
2017-01-01
A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...
Wide-area, real-time monitoring and visualization system
Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.
2013-03-19
A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.
Body surface mounted biomedical monitoring system using Bluetooth.
Nambu, Masayuki
2007-01-01
Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.
RFID and IOT for Attendance Monitoring System
Directory of Open Access Journals (Sweden)
Dedy Irawan Joseph
2018-01-01
Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.
A New Environmental Monitoring System For Silkworm Incubators
Alejandra Duque-Torres; Juan Ruiz-Rosero; Gesille Zambrano-Gonzalez; Martha Almanza-Pinzon; Oscar Mauricio Caicedo Rendon; Gustavo Ramirez-Gonzalez
2018-01-01
A newly Monitoring Environmental Conditions System is proposed based on Raspberry-Pi. This proposal monitors the temperature, humidity, and luminosity in a silkworm incubator. The monitoring data are collected and save in the cloud for the subsequent analysis. The monitoring environmental system is based on Raspberry Pi due to capabilities, features, and low cost. The preliminary tests were realized in a real scenery and the results demonstrating its reliability.
Implant Angle Monitor System of MC3-II
International Nuclear Information System (INIS)
Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi
2008-01-01
Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.
Energy Technology Data Exchange (ETDEWEB)
Mosset, J.-B., E-mail: jean-baptiste.mosset@psi.ch; Stoykov, A.; Greuter, U.; Gromov, A.; Hildebrandt, M.; Panzner, T.; Schlumpf, N.
2017-02-11
A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on a ZnS:{sup 6}LiF scintillator with embedded WLS fibers which are read out with SiPMs. In this paper, we present the 16-ch module, the dedicated readout electronics, a direct comparison between the performance of the diffractometer obtained with the current {sup 3}He detector and with the 16-ch detection module, and the channel-to-channel uniformity.
ZPR-9 airborne plutonium monitoring system
International Nuclear Information System (INIS)
Rusch, G.K.; McDowell, W.P.; Knapp, W.G.
1975-01-01
An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved
IDEA-system - a new computer based expert system for incorporation monitoring
International Nuclear Information System (INIS)
Doerfel, H.
2005-01-01
Full text: There is an increasing number of national and international recommendations and guidelines for incorporation monitoring (ICRP Publications, IAEA Safety Reports, ISO Standards, etc.). These recommendations cover different phases of incorporation monitoring and they provide general requirements for the measuring techniques, the monitoring procedures and for the procedures to evaluate intakes and doses from the monitoring results. There is, however, still a strong need for giving guidance to the dosimetrists on how to apply all the regulations properly. Thus, the EU project IDEAS was launched in order to provide general guidelines for the assessment of internal dose from incorporation monitoring data. These guidelines have recently been discussed in a virtual workshop on the internet (www.ideas-workshop.de) and they are being considered by ICRP for possible adoption in the near future. Recently, in the Karlsruhe Research Centre, a computer-based expert system has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for incorporation monitoring and internal dosimetry. The expert system gives guidance to the user with respect to: planning of monitoring (estimation of potential exposures, decision on the requirements of monitoring, definition of optimum measuring techniques and monitoring intervals); performing routine and special monitoring and evaluation of primary monitoring results. The evaluation of primary monitoring results is done according to the IDEAS guidelines in a threestage procedure according to the expected level of exposure (E = committed effective dose): standard evaluation with default or site specific parameter values (E 6 mSv). With these well-defined procedures the expert system follows the aim, that all recommendations and guidelines are applied properly and thus: internal exposures of more than 1 mSv are very likely to be detected in all situations; the results in terms of committed effective
Development of the simulation monitoring system
International Nuclear Information System (INIS)
Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo
2001-01-01
Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)
Application of Video Recognition Technology in Landslide Monitoring System
Directory of Open Access Journals (Sweden)
Qingjia Meng
2018-01-01
Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.
Corral Monitoring System assessment results
International Nuclear Information System (INIS)
Filby, E.E.; Haskel, K.J.
1998-03-01
This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system
Corral Monitoring System assessment results
Energy Technology Data Exchange (ETDEWEB)
Filby, E.E.; Haskel, K.J.
1998-03-01
This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.
A high reliability oxygen deficiency monitoring system
International Nuclear Information System (INIS)
Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.
1993-05-01
The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings
A high reliability oxygen deficiency monitoring system
International Nuclear Information System (INIS)
Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.
1993-01-01
The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings
An Electrical Energy Consumption Monitoring and Forecasting System
Directory of Open Access Journals (Sweden)
J. L. Rojas-Renteria
2016-10-01
Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.
Monitoring the CMS strip tracker readout system
International Nuclear Information System (INIS)
Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S
2008-01-01
The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system
International Nuclear Information System (INIS)
Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo
2007-01-01
A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)
Reconfigurable Sensor Monitoring System
Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)
2017-01-01
A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.
Upgrade of the monitoring system of LHCb ECAL
Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei
2016-01-01
The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.
System and Method for Monitoring Distributed Asset Data
Gorinevsky, Dimitry (Inventor)
2015-01-01
A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.
Timing and control monitor system upgrade design document. Version 4
International Nuclear Information System (INIS)
Brandt, J.J.
1984-01-01
This is a design document for the Timing and Control Monitor System Upgrade Project. This project is intended to provide a replacement system for the existing user Encoder Monitor Systems and Varian 72 Control Room computer systems. All of these systems reside at the Nevada Test Site. The function of the T and C Monitor System is to gather real-time statistics and data on user defined key variables from control, communication, data acquistion systems, and from the monitoring system itself. The control, communication, and data acquisition systems each operate separately from the monitor system. The T and C Monitor System gathers this data in order to verify the readiness of an event to begin countdown. This includes setup, verification, calibration, and peripheral services, report any failures that may occur during the countdown, verify detonation and containment, and assist reentry activities after the event
Experience with neutron flux monitoring systems qualified for post-accident monitoring
International Nuclear Information System (INIS)
Shugars, H.G.; Miller, J.F.
1995-01-01
In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs
Supervisory monitoring system in nuclear power plants
International Nuclear Information System (INIS)
Ciftcioglu, O.; Turkcan, E.
1997-01-01
Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs
Induced Seismicity Monitoring System
Taylor, S. R.; Jarpe, S.; Harben, P.
2014-12-01
There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range
Remote monitoring of VRLA batteries for telecommunications systems
Energy Technology Data Exchange (ETDEWEB)
Tsujikawa, Tomonobu; Matsushima, Toshio [NTT Facilities Inc., G.H.Y. Building, 2-13-1 Kita-Otsuka, Toshima-ku, Tokyo 170-0004 (Japan)
2007-05-25
This paper describes a remote monitoring system that can be set up in an operating center to monitor the state of valve regulated lead acid batteries (VRLA) used as a backup power supply for telecommunications. This system has a battery voltage monitoring function, a lifetime prediction function based on ambient temperature, and a discharge circuit diagnosis function. In addition, the system can be equipped with an internal resistance measurement function and an electrolyte leakage detection function to further insure power-supply reliability. Various states of batteries observed with the system are transmitted to the remote operating center by a remote monitoring function. This function enables obtaining immediate information about the condition of batteries and helps to avoid unexpected failures. (author)
Performance Monitoring Enterprise Applications with the BlackBird System
Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.
This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.
System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.
Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong
2017-10-01
Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.
Accounting for External Turbulence of Logistics Organizations via Performance Measurement Systems
DEFF Research Database (Denmark)
Bühler, Andreas; Wallenburg, Carl Marcus; Wieland, Andreas
2016-01-01
Purpose: This paper aims to investigate the role of upper management in designing performance measurement systems (PMS) that account for external turbulence of the organization and to show how this PMS design for turbulence impacts organizational resilience and distribution service performance....... Design/methodology/approach: Hypotheses are developed by integrating management accounting and strategic management perspectives into supply chain management and subsequently tested based on data from 431 logistics organizations (i.e. both logistics companies and internal logistics departments...... distribution service performance. Originality/value: This paper is the first to introduce the concept of PMS design for turbulence to the literature and to show that it is relevant for supply chain risk management by fostering the capabilities and the performance of logistics organizations. Further...
A new infusion pathway intactness monitoring system.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton
2006-01-01
A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).
Activity monitoring systems in health care
Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.
2011-01-01
This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After
Geological hazard monitoring system in Georgia
Gaprindashvili, George
2017-04-01
Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.
Monitoring System for ALICE Surface Areas
Demirbasci, Oguz
2016-01-01
I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.
Efficient network monitoring for large data acquisition systems
International Nuclear Information System (INIS)
Savu, D.O.; Martin, B.; Al-Shabibi, A.; Sjoen, R.; Batraneanu, S.M.; Stancu, S.N.
2012-01-01
Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed realtime data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and seamlessly integrates complementary data from auxiliary tools, such as NAGIOS, information services or custom databases. A number of techniques (e.g. normalization, aggregation and data caching) were used in order to improve the user interface response time. The end result is a unified monitoring interface, for fast and uniform access to system statistics, which significantly reduced the time spent by experts for ad-hoc and post-mortem analysis. (authors)
Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.
2005-05-01
The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and
User interface design and system integration aspects of core monitoring systems
International Nuclear Information System (INIS)
Berg, O.; Bodal, T.; Hornaes, A.; Porsmyr, J.
2000-01-01
The present paper describes our experience with the SCORPIO core monitoring system using generic building blocks for the MMI and system integration. In this context the different layers of the software system are discussed starting with the communication system, interfacing of various modules (e.g. physics codes), administration of several modules and generation of graphical user interfaces for different categories of end-users. A method by which re-use of software components can make the system development and maintenance more efficient is described. Examples are given from different system installation projects. The methodology adopted is considered particularly important in the future, as it is anticipated that core monitoring systems will be expanded with new functions (e.g. information from technical specifications, procedures, noise analysis, etc). Further, efficient coupling of off-line tools for core physics calculations and on-line modules in core monitoring can pave the way for cost savings. (authors)
Environmental radiation monitoring system with GPS (global positioning system)
International Nuclear Information System (INIS)
Komoto, Itsuro
2000-01-01
This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)
296-B-10 stack monitoring and sampling system annual system assessment report
International Nuclear Information System (INIS)
Ridge, T.M.
1995-01-01
B Plant Administration Manual, requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with stack 296-B-10 at B Plant. The ventilation system of WESF (Waste Encapsulation and Storage Facility) is designed to provide airflow patterns so that air movement throughout the building is from areas of lesser radioactivity to areas of greater radioactivity. All potentially contaminated areas are maintained at a negative pressure with respect to the atmosphere so that air flows into the building at all times. The exhaust discharging through the 296-B-10 stack is continuously monitored and sampled using a sampling and monitoring probe assembly located approximately 17.4 meters (57 feet) above the base of the stack. The probe assembly consists of 5 nozzles for the sampling probe and 2 nozzles to monitor the flow. The sampling and monitoring system associated with Stack 296-B-10 is functional and performing satisfactorily
RadNet (Environmental Radiation Ambient Monitoring System)
U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...
IDEA system - a new computer-based expert system for incorporation monitoring
International Nuclear Information System (INIS)
Doerfel, H.
2007-01-01
Recently, at the Karlsruhe Research Centre, a computer-based expert system, Internal Dose Equivalent Assessment System (IDEA System), has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for internal dosimetry. The expert system gives guidance to the user with respect to: (a) planning of monitoring, (b) performing routine and special monitoring, and (c) evaluation of primary monitoring results. The evaluation is done according to the IDEA System guidelines (Doerfel, H. et al., General guidelines for the estimation of committed effective dose from incorporation monitoring data. Research Report FZKA 7243, Research Center Karlsruhe, Karlsruhe (2006). ISSN 0947-8260.) in a three-stage procedure according to the expected level of exposure. At the first level the evaluation is performed with default or site-specific parameter values, at the second level case-specific parameter values are applied and at the third level a special evaluation is performed with individual adjustment of model parameter values. With these well-defined procedures the expert system follows the aim, in which all recommendations and guidelines are applied properly and the results in terms of committed effective and organ doses are close to the best estimate. (author)
Monitoring solar-thermal systems: An outline of methods and procedures
Energy Technology Data Exchange (ETDEWEB)
Rosenthal, A. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.
1994-04-01
This manual discusses the technical issues associated with monitoring solar-thermal systems. It discusses some successful monitoring programs that have been implemented in the past. It gives the rationale for selecting a program of monitoring and gives guidelines for the design of new programs. In this report, solar thermal monitoring systems are classified into three levels. For each level, the report discusses the kinds of information obtained by monitoring, the effort needed to support the monitoring program, the hardware required, and the costs involved. Ultimately, all monitoring programs share one common requirement: the collection of accurate data that characterize some aspect or aspects of the system under study. This report addresses most of the issues involved with monitoring solar thermal systems. It does not address such topics as design fundamentals of thermal systems or the relative merits of the many different technologies employed for collection of solar energy.
Ultrafast detection in particle physics and positron emission tomography using SiPMs
Dolenec, R.; Korpar, S.; Križan, P.; Pestotnik, R.
2017-12-01
Silicon photomultiplier (SiPM) photodetectors perform well in many particle and medical physics applications, especially where good efficiency, insensitivity to magnetic field and precise timing are required. In Cherenkov time-of-flight positron emission tomography the requirements for photodetector performance are especially high. On average only a couple of photons are available for detection and the best possible timing resolution is needed. Using SiPMs as photodetectors enables good detection efficiency, but the large sensitive area devices needed have somewhat limited time resolution for single photons. We have observed an additional degradation of the timing at very low light intensities due to delayed events in distribution of signals resulting from multiple fired micro cells. In this work we present the timing properties of AdvanSiD ASD-NUV3S-P-40 SiPM at single photon level picosecond laser illumination and a simple modification of the time-walk correction algorithm, that resulted in reduced degradation of timing resolution due to the delayed events.
Best Management Practices Monitoring Guide for Stream Systems
Mesner, Nancy
2011-01-01
Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.
Air Quality Monitoring System and Benchmarking
DEFF Research Database (Denmark)
Liu, Xiufeng; Nielsen, Per Sieverts
2017-01-01
Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....
The design of radiation monitor passageway system
International Nuclear Information System (INIS)
Chu Chengsheng
2006-10-01
The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)
Development of distributed plant monitoring and diagnosis system at Monju
International Nuclear Information System (INIS)
Okusa, Kyoichi; Tamayama, Kiyoshi; Kitamura, Tomomi
2003-01-01
In a nuclear plant, it is required to detect an anomaly as early as possible and to inhibit adverse consequences. This requirement is especially important for a prototype Fast Breeder Reactor Monju. Therefore, a monitoring and diagnosis system is required to be developed for Monju plant equipments. In these days, such a monitoring and diagnosis system can be realized using Web technology with rationalized system resources due to the remarkable progress of computer network technology. Then, we developed a Web based platform for the monitoring and diagnosis system of Monju. Distributed architecture, standardization and highly flexible system structure have been taken account of in the development. This newly developed platform and prototype monitoring and diagnosis systems have been validated. Prototype monitoring and diagnosis systems on the platform acquire Monju plant data and display the data on client computers using Monju intranet with acceptable delay times. The prototype monitoring and diagnosis systems for Monju have been developed on the platform and the whole system has been validated. (author)
Design Of Pump Monitoring Of Primary Cooling System
International Nuclear Information System (INIS)
Indrakoesoema, Koes; Sujarwono
2000-01-01
Monitoring of 3 primary cooling pumps done visually by operator on the spot. The operator must be check oil in a sight glass, oil leakage during pump operation and water leakage. If reaktor power increase about more than 3 MW, the radiation exposure also increase in the primary cell and that's way the operator can not check the pumps. To continuing monitor all pump without delay, one system has been added I.e Closed Circuit Television (CCTV). This system using 3 video camera to monitor 3 pumps and connected to one receiver video monitor by coaxial cable located in Main Control Room. The sequence monitoring can be done by sequential switcher
Expert systems for real-time monitoring and fault diagnosis
Edwards, S. J.; Caglayan, A. K.
1989-01-01
Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.
Webster, D E; Lu, J; Chen, S-N; Farnsworth, N R; Wang, Z Jim
2006-06-30
The dried ripe fruit of Vitex agnus-castus L. (VAC) is widely used for the treatment of premenstrual syndrome (PMS). A previous study reported that extracts of VAC showed affinity to opiate receptors; however, functional activity was not determined. We tested two different VAC extracts in receptor binding and functional assays. Our objectives were: (1) to confirm the opiate affinity; (2) to rule out interference by free fatty acids (FFA); (3) to determine the mode of action of VAC at the mu-opiate receptor. Methanol extracts of VAC were prepared either before (VAC-M1) or after (VAC-M2) extraction with petroleum ether to remove fatty acids. Both extracts showed significant affinities to the mu-opiate receptor, as indicated by the concentration-dependent displacement of [3H]DAMGO binding in Chinese hamster ovary (CHO)-human mu-opiate receptor (hMOR) cells. The IC50 values were estimated to be 159.8 microg/ml (VAC-M1) and 69.5 microg/ml (VAC-M2). Since the defatted extract not only retained, but exhibited a higher affinity (p<0.001), it argued against significant interference by fatty acids. In an assay to determine receptor activation, VAC-M1 and VAC-M2 stimulated [35S]GTPgammaS binding by 41 and 61% (p<0.001), respectively. These results suggested for the first time that VAC acted as an agonist at the mu-opiate receptor, supporting its beneficial action in PMS.
International Nuclear Information System (INIS)
Dincklage, R.D. von
1982-01-01
A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)
On the use of multi-agent systems for the monitoring of industrial systems
Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil
2016-03-01
The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.
LHCb: Monitoring the DIRAC Distribution System
Nandakumar, R; Santinelli, R
2009-01-01
DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...
Automated wireless monitoring system for cable tension using smart sensors
Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang
2013-04-01
Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.
Do comprehensive performance measurement systems help or hinder managers' mental model development?
Matthew Hall
2011-01-01
This study examines whether and how the process of updating and changing mental models (learning) helps to explain how performance measurement systems (PMS) affect individual performance. Although prior studies (e.g., Hall, 2008; Burney and Widener, 2007; Burney et al., 2009) highlight the important role of particular cognitive and motivational mechanisms, such as role clarity and organizational justice, they do not consider how PMS can improve performance by helping individuals to update the...
Design of smart neonatal health monitoring system using SMCC.
De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita
2017-02-01
Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.
Diagnostic and monitoring systems in nuclear power plants
International Nuclear Information System (INIS)
Wehling, H.J.; Jax, P.; Streicher, V.
1987-01-01
Monitoring systems are important for the availability of nuclear power plants. A survey is given about such systems designed and constructed by the Kraftwerk Union AG Erlangen (Federal Republic of Germany) in order to assure the mechanical integrity of reactor cooling systems. Three monitoring systems based on microprocessors are presented: KUES (acoustic detection of loose parts), SUES (vibration), and FAMOS (fatigue)
Directory of Open Access Journals (Sweden)
Mina Halpern
2010-08-01
Full Text Available OBJECTIVE: To describe the process used to implement a comprehensive, standardized, and reliable national system for data collection for HIV care and treatment in Guyana; to provide examples of the program-level data resulting from implementation; and to highlight the monitoring benefits for national programs. METHODS: In 2007, Guyana's Ministry of Health and other key stakeholders adapted the World Health Organization's generic HIV care and antiretroviral therapy (ART patient monitoring guidelines to fit the Guyana context, which included modifying the patient chart, patient registers, and cross-sectional and cohort reports. Following initial training and feedback from clinical staff, a national patient monitoring system (PMS was finalized, piloted, and implemented at all care and treatment sites. Thereafter, sites received monthly supportive supervisory visits to review data collection and validate reports. RESULTS: Implementation of the PMS enabled analysis of cohort data for patients on ART. After 12 months, 79% of a combined national cohort of all 50 patients who started ART in June 2007 were alive and on first-line ART regimens. After six years, 58% of the first (April 2002 cohort of ART patients in the country were alive and on ART, with only two (8% patients on second-line regimens. CONCLUSIONS: Implementation of a national PMS for standardized data collection and reporting across multiple clinical sites ultimately provided important and reliable information on utilization of services, patient outcomes, and survival rates on treatment. These data are used at the national level to monitor the efficacy of the HIV care and treatment program. Successful implementation requires early inclusion of all committed stakeholders and a dedicated human resource team to ensure sustainability of the system.OBJETIVO: Describir el proceso utilizado con el objeto de poner en práctica un sistema nacional integral, estandarizado y confiable de recopilaci
Decision Fusion System for Bolted Joint Monitoring
Directory of Open Access Journals (Sweden)
Dong Liang
2015-01-01
Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.
Accounting for External Turbulence of Logistics Organizations via Performance Measurement Systems
DEFF Research Database (Denmark)
Bühler, Andreas; Wallenburg, Carl Marcus; Wieland, Andreas
2016-01-01
Purpose: This paper aims to investigate the role of upper management in designing performance measurement systems (PMS) that account for external turbulence of the organization and to show how this PMS design for turbulence impacts organizational resilience and distribution service performance....... Design/methodology/approach: Hypotheses are developed by integrating management accounting and strategic management perspectives into supply chain management and subsequently tested based on data from 431 logistics organizations (i.e. both logistics companies and internal logistics departments...
Methods, apparatus, and systems for monitoring transmission systems
Polk, Robert E [Idaho Falls, ID; Svoboda, John M [Idaho Falls, ID; West, Phillip B [Idaho Falls, ID; Heath, Gail L [Iona, ID; Scott, Clark L [Idaho Falls, ID
2010-08-31
A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.
A monitor system for end cap shower counter of Beijing spectrometer
International Nuclear Information System (INIS)
Wang Man; Xia Xiaomi; Lai Yuanfen; Cheng Baosen; Li Jin
1993-01-01
To keep a large-scale detector system running in a correct condition and to obtain some correct parameters, it is necessary to have a monitor system monitoring the detector system operation in real time. In the paper, the structure of End Cap Shower Counter monitor system of Beijing Spectrometer is described. Some properties of this monitor system and the real-time monitoring results during operation of Beijing Spectrometer are given
Implementation of medical monitor system based on networks
Yu, Hui; Cao, Yuzhen; Zhang, Lixin; Ding, Mingshi
2006-11-01
In this paper, the development trend of medical monitor system is analyzed and portable trend and network function become more and more popular among all kinds of medical monitor devices. The architecture of medical network monitor system solution is provided and design and implementation details of medical monitor terminal, monitor center software, distributed medical database and two kind of medical information terminal are especially discussed. Rabbit3000 system is used in medical monitor terminal to implement security administration of data transfer on network, human-machine interface, power management and DSP interface while DSP chip TMS5402 is used in signal analysis and data compression. Distributed medical database is designed for hospital center according to DICOM information model and HL7 standard. Pocket medical information terminal based on ARM9 embedded platform is also developed to interactive with center database on networks. Two kernels based on WINCE are customized and corresponding terminal software are developed for nurse's routine care and doctor's auxiliary diagnosis. Now invention patent of the monitor terminal is approved and manufacture and clinic test plans are scheduled. Applications for invention patent are also arranged for two medical information terminals.
Remote monitoring system workshop and technical cooperation
Energy Technology Data Exchange (ETDEWEB)
Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W
2000-06-01
RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.
Remote monitoring system workshop and technical cooperation
International Nuclear Information System (INIS)
Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W.
2000-06-01
RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person
Research and Implementation of Distributed Database HBase Monitoring System
Directory of Open Access Journals (Sweden)
Guo Lisi
2017-01-01
Full Text Available With the arrival of large data age, distributed database HBase becomes an important tool for storing data in massive data age. The normal operation of HBase database is an important guarantee to ensure the security of data storage. Therefore designing a reasonable HBase monitoring system is of great significance in practice. In this article, we introduce the solution, which contains the performance monitoring and fault alarm function module, to meet a certain operator’s demand of HBase monitoring database in their actual production projects. We designed a monitoring system which consists of a flexible and extensible monitoring agent, a monitoring server based on SSM architecture, and a concise monitoring display layer. Moreover, in order to deal with the problem that pages renders too slow in the actual operation process, we present a solution: reducing the SQL query. It has been proved that reducing SQL query can effectively improve system performance and user experience. The system work well in monitoring the status of HBase database, flexibly extending the monitoring index, and issuing a warning when a fault occurs, so that it is able to improve the working efficiency of the administrator, and ensure the smooth operation of the project.
PC based vibration monitoring system
International Nuclear Information System (INIS)
Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.
2004-01-01
Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)
Development of an enhanced loose parts monitoring system (LPMS)
International Nuclear Information System (INIS)
Choi, Y. C.; Park, J. H.; Yoon, D. B.; Choi, K. S.; Sohn, C. H.
2006-01-01
LPMS (loose parts monitoring system) is one of the most important structural integrity monitoring systems. It is operated for a early detection of the impacts by loosened or detached metallic, objects on the primary pressure boundary in a nuclear power plant. The impacted parts might cause flow blockage in the fuel channel, prevent the control rod from moving properly, damage the pump impeller, and give rise to cracks on the steam generator tube sheet, etc. In Korea, The LPMS is currently operating in all of the nuclear power plants as a subsystem in the NIMS (NSSS Integrity Monitoring System), However the performances are being deteriorated in both the hardware and software since it was designed in 1980's. In particular the system is not capable of promptly responding to the continuously triggered impacts in a short period failing to monitor the real loose parts. Also the diagnostic tools to estimate the location and the mass or energy of the impact source have not been reflected. Therefore, a new loose parts monitoring system has been developed to improve the capabilities of the current one and ultimately to replace it. An enhanced Loose Parts Monitoring System(LPMS) has been developed by KAERI(Korea Atomic Energy Research Inst.), not only to improve the performance of an on-line signal processing for a monitoring system but also to enhance the evaluation technique of the true impact signals by loose parts. This new system has taken into account the state-of-the-art technology to cover the problems with the conventional system. (authors)
Environmental monitoring systems: a new type of mobile laboratory
International Nuclear Information System (INIS)
Bruecher, L.; Langmueller, G.; Tuerschmann, G.
1999-01-01
Nuclear facilities are obligated to monitor the environmental radiation in their vicinity, which is often fulfilled by monitoring cars, combined with fixed monitoring stations. The MOLAR Mobile Laboratory for Environmental Radiation Monitoring as described here is being used under normal and accident conditions as a spot check monitoring system or to perform continuous measurements along a driving track. The mobile laboratories are continuously connected with the control centre's CRCS Central Radiological Computer System, where the RIS Radiological Information System provides corresponding evaluation functions. The mobile labs contain measuring and controlling units like γ-dose rate monitors, γ-spectrometer with a HpGe High Purity Germanium detector, a lead shielded measuring cell and MCA Multi-Channel Analyser, portable β-contamination monitor, α/β/γ multipurpose quick measuring unit, aerosol and iodine sampling units. The collected samples are safely stored for the transport to the environmental laboratory for being analysed later. The geographical location of the moving car is continuously determined by the satellite based GPS Global Positioning System and transferred in the on-board rack mounted computer system for being stored and locally displayed. Real-time data transmission via radio and mobile phone is continuously performed to supply the RIS Radiological Information System in the control centre via radio and mobile phone. The latter also serves for voice communication. Currently three MOLAR systems can be operated parallel and independent from the control centre. The system is ready to be extended to more mobile labs. This combination of mobile monitoring, sample analysis and radiological assessment of environmental data in combination with process occurrences has turned out to be a powerful instrument for emergency preparedness and environmental supervising. (orig.) [de
Design of multi-channel analyzer's monitoring system based on embedded system
International Nuclear Information System (INIS)
Yang Tao; Wei Yixiang
2007-01-01
A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)
Limerick Nuclear Generating Station vibration monitoring system
International Nuclear Information System (INIS)
Mikulski, R.
1988-01-01
Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed
Study on intermediate frequency power supply automatic monitor system
International Nuclear Information System (INIS)
Wang Yuntong; Xu Bin
2007-06-01
A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)
An integrated system for pipeline condition monitoring
Energy Technology Data Exchange (ETDEWEB)
Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)
2009-07-01
In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable
BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS
Directory of Open Access Journals (Sweden)
G. Rajesh
2014-09-01
Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.
Directory of Open Access Journals (Sweden)
Esther M. Maimela
2016-10-01
Full Text Available Orientation: Institutions of higher learning in South Africa are fast embracing performance management system (PMS as a mechanism for the achievement of teaching excellence and enhancement of research productivity. However, literature provided evidence to show that application of PMS in the private sector had failed to drive competition, efficiency and productivity. Research purpose: The main purpose of this article was to evaluate the perception of academic staff members of an open distance learning institution regarding the implementation of a PMS. Motivation for the study: PMS as a mechanism through which performance of academics is measured has been described as inconsistent with the long tradition of academic freedom, scholarship and collegiality in the academy. Moreso, previous research on the implementation of PMS was limited to private sector organisations, thus resulting in the dearth of empirical literature relating to its practice in service-driven public sector institutions. Research design, approach and method: The article adopted a quantitative research approach using census survey methodology. Data were collected from 492 academic staff from the surveyed institution using a self-developed questionnaire that was tested for high content validity with a consolidated Cronbach’s alpha value of 0.83. Data were analysed using a onesample t-test because of the one-measurement nature of the variable under investigation. Main findings: Major findings of the study indicated that respondents were satisfied with the implementation of the PMS by management. However, the payment of performance bonuses was not considered as sufficiently motivating, thus necessitating a pragmatic review by management. Practical/managerial implications: The findings of this article provided a practical guide to managers on the implementation and management of PMS as an employee performance reward mechanism in non-profit and service-oriented organisations
The Wettzell System Monitoring Concept and First Realizations
Ettl, Martin; Neidhardt, Alexander; Muehlbauer, Matthias; Ploetz, Christian; Beaudoin, Christopher
2010-01-01
Automated monitoring of operational system parameters for the geodetic space techniques is becoming more important in order to improve the geodetic data and to ensure the safety and stability of automatic and remote-controlled observations. Therefore, the Wettzell group has developed the system monitoring software, SysMon, which is based on a reliable, remotely-controllable hardware/software realization. A multi-layered data logging system based on a fanless, robust industrial PC with an internal database system is used to collect data from several external, serial, bus, or PCI-based sensors. The internal communication is realized with Remote Procedure Calls (RPC) and uses generative programming with the interface software generator idl2rpc.pl developed at Wettzell. Each data monitoring stream can be configured individually via configuration files to define the logging rates or analog-digital-conversion parameters. First realizations are currently installed at the new laser ranging system at Wettzell to address safety issues and at the VLBI station O Higgins as a meteorological data logger. The system monitoring concept should be realized for the Wettzell radio telescope in the near future.
Aerospace Systems Monitor, Phase II
National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...
A dose monitoring system for dental radiography
Energy Technology Data Exchange (ETDEWEB)
Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)
2016-06-15
The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.
A dose monitoring system for dental radiography
International Nuclear Information System (INIS)
Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young
2016-01-01
The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose
A low frequency RFI monitoring system
Amiri, Shahram; Shankar, N. Udaya; Girish, B. S.; Somashekar, R.
Radio frequency interference (RFI) is a growing problem for research in radio astronomy particularly at wavelengths longer than 2m. For satisfactory operation of a radio telescope, several bands have been protected for radio astronomy observations by the International Telecommunication Union. Since the radiation from cosmic sources are typically 40 to 100 dB below the emission from services operating in unprotected bands, often the out-of-band emission limits the sensitivity of astronomical observations. Moreover, several radio spectral emissions from cosmic sources are present in the frequency range outside the allocated band for radio astronomy. Thus monitoring of RFI is essential before building a receiver system for low frequency radio astronomy. We describe the design and development of an RFI monitoring system operating in the frequency band 30 to 100 MHz. This was designed keeping in view our proposal to extend the frequency of operation of GMRT down to 40 MHz. The monitor is a PC based spectrometer recording the voltage output of a receiver connected to an antenna, capable of digitizing the low frequency RF directly with an 8 bit ADC and sampling bandwidths up to 16 MHz. The system can operate continuously in almost real-time with a loss of only 2% of data. Here we will present the systems design aspects and the results of RFI monitoring carried out at the Raman Research Institute, Bangalore and at the GMRT site in Khodad.
Wireless patient monitoring system for a moving-actuator type artificial heart.
Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G
2006-10-01
In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.
296-B-5 Stack monitoring and sampling system annual system assessment report
International Nuclear Information System (INIS)
Ridge, T.M.
1995-02-01
The B Plant Administration Manual requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with Stack 296-B-5 at B Plant. The sampling and monitoring system associated with stack 296-B-5 is functional and performing satisfactorily. This document is an annual assessment report of the systems associated with the 296-B-5 stack
EDGAR, a new plant radiation monitoring system
International Nuclear Information System (INIS)
Vuong, Q.M.; Da Costa Vieira, D.
2004-01-01
The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)
Optimising corrosion monitoring in district heating systems
DEFF Research Database (Denmark)
Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.
2002-01-01
A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...
Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility
Energy Technology Data Exchange (ETDEWEB)
You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P
2006-09-15
The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO{sub 2} into U-metal. For demonstration of this process, {alpha}-{gamma} type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for {gamma}-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.
Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility
International Nuclear Information System (INIS)
You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.
2006-09-01
The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for γ-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration
[Development of automatic urine monitoring system].
Wei, Liang; Li, Yongqin; Chen, Bihua
2014-03-01
An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.
Quaternion Based Thermal Condition Monitoring System
Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee
In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.
Integrated monitoring of wind plant systems
Whelan, Matthew J.; Janoyan, Kerop D.; Qiu, Tong
2008-03-01
Wind power is a renewable source of energy that is quickly gaining acceptance by many. Advanced sensor technologies have currently focused solely on improving wind turbine rotor aerodynamics and increasing of the efficiency of the blade design and concentration. Alternatively, potential improvements in wind plant efficiency may be realized through reduction of reactionary losses of kinetic energy to the structural and substructural systems supporting the turbine mechanics. Investigation of the complete dynamic structural response of the wind plant is proposed using a large-scale, high-rate wireless sensor network. The wireless network enables sensors to be placed across the sizable structure, including the rotating blades, without consideration of cabling issues and the economic burden associated with large spools of measurement cables. A large array of multi-axis accelerometers is utilized to evaluate the modal properties of the system as well as individual members and would enable long-term structural condition monitoring of the wind turbine as well. Additionally, environmental parameters, including wind speed, temperature, and humidity, are wirelessly collected for correlation. Such a wireless system could be integrated with electrical monitoring sensors and actuators and incorporated into a remote multi-turbine centralized plant monitoring and control system.
Implementation of remove monitoring in facilities under safeguards with unattended systems
International Nuclear Information System (INIS)
Beddingfield, David H.; Nordquist, Heather A.; Umebayaashi, Eiji
2009-01-01
Remote monitoring is being applied by the International Atomic Energy Agency (IAEA) at nuclear facilities around the world. At the Monju Reactor in Japan we have designed, developed and implemented a remote monitoring approach that can serve as a model for applying remote monitoring to facilities that are already under full-scope safeguards using unattended instrumentation. Remote monitoring implementations have historically relied upon the use of specialized data collection hardware and system design features that integrate remote monitoring into the safeguards data collection system. The integration of remote monitoring and unattended data collection increases the complexity of safeguards data collection systems. This increase in complexity necessarily produces a corresponding reduction of system reliability compared to less-complex unattended monitoring systems. At the Monju facility we have implemented a remote monitoring system that is decoupled from the activity of safeguards data collection. In the completed system the function of remote data transfer is separated from the function of safeguards data collection. As such, a failure of the remote monitoring function cannot produce an associated loss of safeguards data, as is possible with integrated remote-monitoring implementations. Currently, all safeguards data from this facility is available to the IAEA on a 24/7 basis. This facility employs five radiation-based unattended systems, video surveillance and numerous optical seal systems. The implementation of remote monitoring at this facility, while increasing the complexity of the safeguards system, is designed to avoid any corresponding reduction in reliability of the safeguards data collection systems by having decoupled these functions. This design and implementation can serve as a model for implementation of remote monitoring at nuclear facilities that currently employ unattended safeguards systems.
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System
Sungjun Kwon; Dongseok Lee; Jeehoon Kim; Youngki Lee; Seungwoo Kang; Sangwon Seo; Kwangsuk Park
2016-01-01
In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user?s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user?s high-level contexts, such as stress and affective state levels. In th...
Personnel external dose monitoring system
International Nuclear Information System (INIS)
Zhao Hengyuan
1989-01-01
The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given
Performance management system in sale and distribution: A case of Serbian company
Directory of Open Access Journals (Sweden)
Aleksandar Jankulović
2013-09-01
Full Text Available Background: Performance management system (PMS is the process of quantifying action which leads to organizational efficiency, competitiveness and growth. Performance measurement is the vital element of quality management system (QMS. Innovative companies have a strong culture, clear sense of mission and purpose, a well thought out strategy and business philosophy of continuous improvement, driven by QMS. Implementation of QMS ISO9001 standards has encouraged many organizations to develop and implement performance management system. Statement of quality objectives and Measurement, analysis and improvement as a part of QMS which leads to continual improvement is a vital part of success of company. Therefore PMS influence on sale, distribution and logistics companies with a complex processes and great number of subjects in supply chain are of great importance for their success. Methods: In our research we analyse measures and measurement approaches and frameworks that exist in logistic management and based on that we present results from one SME from eastern European country. We use case study research and therefore we conduct interviews with managers, employees and QMS/PMS implementation staff in sale and distribution company. Results: The aim of this study was to estimate the value of various metrics of the evaluation of QMS implementation. The study was based on case study in one Serbian sale and distribution company specifically in measurement part and metrics that are essential for their business and to compare them with approaches existed in literature. We reveal some obstacles in collecting data for measurement and benchmarking in Serbian market. Different metrics for efficient management of company are implemented in this company based on sales results and customer satisfaction. Conclusion: The importance of the research is in the fact that implementation of QMS reveal the need for PMS implementation and therefore results in certain
MINED GEOLOGIC DISPOSAL SYSTEM (MGDS) MONITORING AND CONTROL SYSTEMS CENTRALIZATION TECHNICAL REPORT
International Nuclear Information System (INIS)
M.J. McGrath
1998-01-01
The objective of this report is to identify and document Mined Geologic Disposal System (MGDS) requirements for centralized command and control. Additionally, to further develop the MGDS monitoring and control functions. This monitoring and control report provides the following information: (1) Determines the applicable requirements for a monitoring and control system for repository operations and construction (excluding Performance Confirmation). (2) Makes a determination as to whether or not centralized command and control is required
Real time kernel performance monitoring with SystemTap
CERN. Geneva
2018-01-01
SystemTap is a dynamic method of monitoring and tracing the operation of a running Linux kernel. In this talk I will present a few practical use cases where SystemTap allowed me to turn otherwise complex userland monitoring tasks in simple kernel probes.
Operational experience with two tritium-effluent-monitoring systems
International Nuclear Information System (INIS)
Haynie, J.S.; Gutierrez, J.A.
1982-01-01
Two new tritium stack monitoring systems were designed and built. The operational experience of a wide-range detector with a useful range of a few μCi/m 3 to 10 8 μCi/m 3 , and a second monitoring system using an improved Kanne chamber and a new electrometer, called a Model 39 Electrometer-Chargemeter are discussed. Both tritium chambers have been designed to have a reduced sensitivity to tritium contamination, a fast response, and an integrating chargemeter with digital readout for easy conversion to microcuries. The calibration of these monitors and advantages of using these chambers over conventional systems are discussed
Quebec firm develops satellite monitoring system
Energy Technology Data Exchange (ETDEWEB)
Anon
2004-09-01
Satellite-based technology that gives project owners an affordable way to monitor and control wind turbine operation, even in remote sites, is announced. Called Satwind, the system can be adapted to any scale, ranging from simple, low-cost units for small wind turbines to advanced versions designed to handle more complex wind-diesel installations, as well as large turbines used in offshore projects. Current installations include a turbine in the Tunisian desert and two Quebec wind-diesel plants accessible only by helicopter. The system can be operated directly from a cell-phone, in a user-friendly Internet manner, without the need to be connected to a complex centralized wind farm monitoring system.
Performace Of Multi-Probe Corrosion Monitoring Systems At The Hanford Site
International Nuclear Information System (INIS)
Carothers, K.D.; Boomer, K.D.; Anda, V.S.; Dahl, M.M.; Edgemon, G.L.
2010-01-01
Between 2007 and 2009, several different multi-probe corrosion monitoring systems were designed and installed in high-level nuclear waste tanks at the U.S. Department of Energy's Hanford Site in WaShington State. The probe systems are being monitored to ensure waste tanks operate in regions that minimize localized corrosion (i.e., pitting) and stress corrosion cracking. The corrosion monitoring systems have been installed in wastes with different chemistry types. An ongoing effort during the same time period has generated non-radioactive simulants that are tested in the laboratory to establish baseline corrosion monitoring system performance and characterize data to allow interpretation of readings from the multiple corrosion monitoring systems. Data collection from these monitoring systems has reached the point where the results allow comparison with the laboratory testing. This paper presents analytical results from the corrosion monitoring system development program.
Computerized x-ray dose-monitoring system
International Nuclear Information System (INIS)
Hummel, R.H.; Wesenberg, R.L.; Amundson, G.M.
1985-01-01
An x-ray dose-monitoring system using a small digital computer is described. Initially, and for every 6 months afterward, the system is calibrated using an exposure meter. For each exposure, the computer receives values of x-ray technique and beam geometry from the x-ray generator through a specially designed electronic interface. Then, by means of calibration data, entrance exposure, area exposure product, and integral dose are obtained and printed for each patient examined. The overall accuracy of the system is better than +/-20%. Operation is semiautomatic, requiring minimum operator intervention. Over 2000 patients have been monitored with the device. Because the system is computer-based, it offers the opportunity for statistical analysis of the data base created, as the results for each patient are stored on computer disk
Background compensation methodologies for contamination monitoring systems
International Nuclear Information System (INIS)
Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.
2014-01-01
Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases
Systems engineering approach towards performance monitoring of emergency diesel generator
International Nuclear Information System (INIS)
Nurhayati Ramli; Lee, Y.K.
2013-01-01
Full-text: Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort. (author)
G-Cloud Monitor: A Cloud Monitoring System for Factory Automation for Sustainable Green Computing
Directory of Open Access Journals (Sweden)
Hwa-Young Jeong
2014-11-01
Full Text Available Green and cloud computing (G-cloud are new trends in all areas of computing. The G-cloud provides an efficient function, which enables users to access their programs, systems and platforms at anytime and anyplace. Green computing can also yield greener technology by reducing power consumption for sustainable environments. Furthermore, in order to apply user needs to the system development, the user characteristics are regarded as some of the most important factors to be considered in product industries. In this paper, we propose a cloud monitoring system to observe and manage the manufacturing system/factory automation for sustainable green computing. For monitoring systems, we utilized the resources in the G-cloud environments, and hence, it can reduce the amount of system resources and devices, such as system power and processes. In addition, we propose adding a user profile to the monitoring system in order to provide a user-friendly function. That is, this function allows system configurations to be automatically matched to the individual’s requirements, thus increasing efficiency.
Development of CANDU core monitoring system
International Nuclear Information System (INIS)
Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H.
2003-01-01
The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1
Development of CANDU core monitoring system
Energy Technology Data Exchange (ETDEWEB)
Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H. [Institute for Advanced Engineering, Yongin (Korea, Republic of)
2003-07-01
The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1.
Evaluation of a multiport groundwater monitoring system
International Nuclear Information System (INIS)
Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.
1991-03-01
In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs
Data monitoring system for PV solar generators
International Nuclear Information System (INIS)
Stoev, M.; Katerski, A.; Williams, A.
2000-01-01
The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created
Real-Time Spatial Monitoring of Vehicle Vibration Data as a Model for TeleGeoMonitoring Systems
Robidoux, Jeff
2005-01-01
This research presents the development and proof of concept of a TeleGeoMonitoring (TGM) system for spatially monitoring and analyzing, in real-time, data derived from vehicle-mounted sensors. In response to the concern for vibration related injuries experienced by equipment operators in surface mining and construction operations, the prototype TGM system focuses on spatially monitoring vehicle vibration in real-time. The TGM vibration system consists of 3 components: (1) Data Acquisition ...
Advancing satellite operations with intelligent graphical monitoring systems
Hughes, Peter M.; Shirah, Gregory W.; Luczak, Edward C.
1993-01-01
For nearly twenty-five years, spacecraft missions have been operated in essentially the same manner: human operators monitor displays filled with alphanumeric text watching for limit violations or other indicators that signal a problem. The task is performed predominately by humans. Only in recent years have graphical user interfaces and expert systems been accepted within the control center environment to help reduce operator workloads. Unfortunately, the development of these systems is often time consuming and costly. At the NASA Goddard Space Flight Center (GSFC), a new domain specific expert system development tool called the Generic Spacecraft Analyst Assistant (GenSAA) has been developed. Through the use of a highly graphical user interface and point-and-click operation, GenSAA facilitates the rapid, 'programming-free' construction of intelligent graphical monitoring systems to serve as real-time, fault-isolation assistants for spacecraft analysts. Although specifically developed to support real-time satellite monitoring, GenSAA can support the development of intelligent graphical monitoring systems in a variety of space and commercial applications.
On-line monitoring system for utility boiler diagnostics
International Nuclear Information System (INIS)
Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.
1997-01-01
The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)
The Westinghouse BEACON on-line core monitoring system
International Nuclear Information System (INIS)
Buechel, Robert J.; Boyd, William A.; Casadei, Alberto L.
1995-01-01
BEACON (Best Estimate Analysis of Core Operations - Nuclear), a core monitoring and operational support package developed by Westinghouse, has been installed at many operating PWRs worldwide. The BEACON system is a real-time monitoring system which can be used in plants with both fixed and movable incore detector systems and utilizes an on-line nodal model combined with core instrumentation data to provide continuous core power distribution monitoring. In addition, accurate core-predictive capabilities utilizing a full core nodal model updated according to plant operating history can be made to provide operational support. Core history information is kept and displayed to help operators anticipate core behavior and take pro-active control actions. The BEACON system has been licensed by the U.S. Nuclear Regulatory Commission for direct, continuous monitoring of DNBR and peak linear heat rate. This allows BEACON to be integrated into the plant technical specifications to permit significant relaxation of operating limitations defined by conventional technical specifications. (author). 4 refs, 2 figs, 1 tab
Tuning permissiveness of active safety monitors for autonomous systems
Masson , Lola; Guiochet , Jérémie; Waeselynck , Hélène; Cabrera , Kalou; Cassel , Sofia; Törngren , Martin
2018-01-01
International audience; Robots and autonomous systems have become a part of our everyday life, therefore guaranteeing their safety is crucial.Among the possible ways to do so, monitoring is widely used, but few methods exist to systematically generate safety rules to implement such monitors. Particularly, building safety monitors that do not constrain excessively the system's ability to perform its tasks is necessary as those systems operate with few human interventions.We propose in this pap...
Developing a performance measurement system for public research centres
Directory of Open Access Journals (Sweden)
Masella, C.
2012-01-01
Full Text Available This study aims at developing a performance measurement system (PMS for research and development (R&D activities carried out by public research centres. Public research institutions are characterized by multiple stakeholders with different needs, and the management of R&D activities requires balancing the multiple goals of different stakeholders. This characteristic is a key issue in the process of construction of the PMS. Empirical evidence is provided by an Italian public research centre, where the researchers carried out a project aimed to develop a PMS following action research principles. This project gave the possibility to researchers to interact with different stakeholders and integrate their different information needs in a comprehensive set of key performance indicators (KPIs. As a result, multidimensional framework for measuring R&D performance in a public research centre is proposed and a set of Key Performance Indicators is developed, suggesting implications for academics and practitioners.
ATLAS Tile calorimeter calibration and monitoring systems
Marjanovic, Marija; The ATLAS collaboration
2018-01-01
The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibers to photo-multiplier tubes (PMTs), located in the outer part of the calorimeter. The readout is segmented into about 5000 cells, each one being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of the full readout chain during the data taking, a set of calibration sub-systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements, and an integrator based readout system. Combined information from all systems allows to monitor and to equalize the calorimeter response at each stage of the signal evolution, from scintillation light to digitization. Calibration runs are monitored from a data quality perspective and u...