WorldWideScience

Sample records for monitoring system ims

  1. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  2. Detection of Atmospheric Explosions at IMS Monitoring Stations using Infrasound Techniques

    National Research Council Canada - National Science Library

    Christie, Douglas R; Kennett, Brian L; Tarlowski, Chris

    2006-01-01

    Work is continuing on the development of infrasound techniques that can be used to improve detection, location and discrimination capability for atmospheric nuclear explosions at International Monitoring System (IMS...

  3. General technical requirements (GTR) for inventory monitoring systems (IMS) for the trilateral initiative

    International Nuclear Information System (INIS)

    Pshakin, Gennady M.; Kuleshov, I.; Shea, T.; Puckett, J.M.; Zhukov, I.; Mangan, Dennis L.; Matter, John C.; Waddoups, I.; Smathers, D.; Abhold, M.E.; Hsue, S.-T.; Chiaro, P.

    2002-01-01

    Pursuant to the Trilateral Initiative, the three parties (The Russian Federation, the United States, and the International Atomic Energy Agency) have been engaged in discussions concerning the structure of reliable monitoring systems for storage facilities having large inventories. The intent of these monitoring systems is to provide the capability for the IAEA to maintain continuity of knowledge in a sufficiently reliable manner that should there be equipment failure, loss of continuity of knowledge would be restricted to a small population of the inventory, and thus reinventory of the stored items would be minimized These facility-specific monitoring systems, referred to as Inventory Monitoring Systems (IMS) are to provide the principal means for the M A to assure that the containers of fissile material remain accounted under the Verification Agreements which are to be concluded between the IAEA and the Russian Federation and the lAEA and the United States for the verification of weapon-origin and other fissile material specified by each State as released from its defense programs. A technical experts working group for inventory monitoring systems has been meeting since Feb- of 2000 to formulate General Technical Requirements (GTR) for Inventory Monitoring Systems for the Trilateral Initiative. Although provisional agreement has been reached by the three parties concerning the GTR, it is considered a living document that can be updated as warranted by the three parties. This paper provides a summary of the GTR as it currently exists.

  4. International Monitoring system (IMS) build-up in Africa: Current status and the way forward

    International Nuclear Information System (INIS)

    Basham, P.

    2002-01-01

    The complete IMS verification system for primary and auxiliary seismic together with that of radionuclide, hydroacoustic and infrasound is plotted on a global map and Africa in particular showing its status. IMS situation in East and Southern Africa is included

  5. Design of data transportation based on dual-port RAM in IMS system

    International Nuclear Information System (INIS)

    Zhang Guohui; Li Yongping

    2010-01-01

    Ion mobility spectroscopy (IMS) is a rugged, portable, sensitive, low cost, field instrumental technique capable of trace organic detection and monitoring for environmental pollutants, pesticides, explosives, narcotics, and other analytes, hence it is of great significance to social security and stability. High rate data transmission mechanism between DSP processor and ARM core is required in the electronic system of IMS. After careful comparison of UART and dual port RAM, a new design based on dual port RAM that can be applied to other similar systems. (authors)

  6. The CTBT : New Zealand's involvement in the international monitoring system

    International Nuclear Information System (INIS)

    Matthews, M.

    1998-01-01

    The Comprehensive Test-Ban Treaty (CTBT), to which most countries are now signatories, is seen as a major step towards the curtailment of nuclear weapons production and eventual disarmament. The Treaty can only be effectively implemented, however, if there is a monitoring system in place to verify that weapons testing is not taking place and, if it does occur, to identify the violator. The diesign of the International Monitoring System (IMS) has therefore been a significant part of the Treaty negotiations. This article focuses o New Zealand's involvement in the IMS, in atmospheric radioactivity and infrasound monitoring. Because of its history of involvement in environmental monitoring, National Radiation Laboratory (NRL) has been providing expert input into Treaty negotiations concerning the radionucled component of the IMS. The Institute of Geological and Nuclear Sciences (IGNS) monitors seismic activity at a number of locations in New Zealand and the South Pacific, and has also provided expert input to the design of the global seismic component of the IMS. The New Zealand government has offered the monitoring facilities of NRL and IGNS for inclusion in the global IMS. (author)

  7. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    Science.gov (United States)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  8. Monitoring and crisis system of radiation safety

    International Nuclear Information System (INIS)

    Bartok, J.; Borovansky, P.; Macica, J.; Petrovicova, M.

    2005-01-01

    In this paper we have briefly described our practical experiences with the most complex Radiation Monitoring System we have designed. This system consists of number of stations; those data are collected in the main crisis center of the whole system. The main center integrates RMS Central Database, the IMS Model Suite workstation and the Graphics workstation. The radiations probes of the RP series are the base for stationary , portable sets and for sets measuring underwater radiation. The radiation and meteorological data, which are necessary for reasonable interpretation of radiation data, are archived in RMS Central database. The Lagrangian trajectory model from the IMS Model Suite serves for radiation dispersion modeling. (authors)

  9. An IMS Station life cycle from a sustainment point of view

    Science.gov (United States)

    Brely, Natalie; Gautier, Jean-Pierre; Foster, Daniel

    2014-05-01

    The International Monitoring System (IMS) is to consist of 321 monitoring facilities, composed of four different technologies with a variety of designs and equipment types, deployed in a range of environments around the globe. The International Monitoring System is conceived to operate in perpetuity through maintenance, replacement and recapitalization of IMS facilities' infrastructure and equipment when the end of service life is reached [CTBT/PTS/INF.1163]. Life Cycle techniques and modellization are being used by the PTS to plan and forecast life cycle sustainment requirements of IMS facilities. Through historical data analysis, Engineering inputs and Feedback from experienced Station Operators, the PTS currently works towards increasing the level of confidence on these forecasts and sustainment requirements planning. Continued validation, feedback and improvement of source data from scientific community and experienced users is sought and essential in order to ensure limited effect on data availability and optimal costs (human and financial).

  10. Information Management System (Ims) For Gender Mainstreaming In ...

    African Journals Online (AJOL)

    Information Management System (IMS) is an essential tool in supporting the provision of information needed for planning and decision making in any organization. Proper IMS facilitates the smooth flow of information both vertical and horizontal. This paper presents the findings of a survey on information needs of the Gender ...

  11. Quick scan IMS vendors

    NARCIS (Netherlands)

    Norp, A.H.J.; Pals, H.; Walraven, F.A.

    2007-01-01

    IMS is gaining momentum in the market. First operators are deploying IMS, while other operators are considering buying IMS. Operators have two approaches for introducing IMS and building an IMS eco-system: • Buying IMS from a large vendor or system integrator. Vendors like Alcatel-Lucent, Ericsson

  12. Radiological information management system (RadIMS)

    International Nuclear Information System (INIS)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-01-01

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, ''Radiation Protection for Occupational Workers.'' This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps

  13. Radiological information management system (RadIMS)

    Energy Technology Data Exchange (ETDEWEB)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-08-19

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, Radiation Protection for Occupational Workers.'' This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps.

  14. Radiological information management system (RadIMS)

    Energy Technology Data Exchange (ETDEWEB)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-08-19

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, ``Radiation Protection for Occupational Workers.`` This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps.

  15. CORPORATIVE MOTIVES ON IMPLEMENTATION OF INTEGRATED MANAGEMENT SYSTEM (IMS

    Directory of Open Access Journals (Sweden)

    Dragan Rajkovic

    2009-09-01

    Full Text Available Integration of management systems for quality, environment, health and risk management as well as corporative social responsibilities is workable corporative approach to reduce costs, effective use of resources, higher motivation of employees and better fulfillment of requirements of social engagements and stakeholders. This paper presents contents of literature and review of a company motives on integrated management system (IMS implementation, namely factors affecting the IMS implementation.

  16. An overview of CTBT verification technologies and status of IMS networks

    International Nuclear Information System (INIS)

    Basham, P.

    2002-01-01

    The CTBT history is described in brief. Nuclear test environments and verification regime are presented with illustrations. Geographical location of seismic, hydroacoustic, infrasound and radionuclide monitoring networks are indicated on globe maps. Benefits of the International Monitoring System (IMS) to host countries are listed

  17. The International Monitoring System's Noble Gas Network

    International Nuclear Information System (INIS)

    Auer, M.

    2015-01-01

    The International Monitoring System (IMS) is a unique global network for surveillance of the Comprehensive Nuclear-Test-Ban Treaty. A major component of the IMS is the radionuclide monitoring network since, among all IMS technologies, it can provide the most unequivocal evidence for a nuclear explosion. The radionuclide monitoring component is unprecedented in its combination of global coverage, sensitivity, network density and temporal resolution. In particular for the detection of underground or underwater nuclear tests, forty of the eighty radionuclide stations will eventually be equipped with sensors to measure the Xenon isotopes Xe-131m (τ 1/2 = 11:8 d), Xe-133 (τ 1/2 = 5:25 d), Xe-133m (τ 1/2 = 2:2 d) and Xe-135 (τ 1/2 = 9:14 h). These are among the isotopes with the highest yields in fission of uranium or plutonium with half-lives long enough to be detected at large distances from the point of emission. As of today, 31 noble gas systems have been installed and are sending data to the International Data Centre. The noble gas systems installed at the stations are automated and sample Xenon continuously from atmospheric air for 12 or 24 hours at an air flow of 0.5 to several m 3 /h by absorption of Xenon on activated charcoal. Detection of the Xenon isotopes is either by high resolution gamma spectrometry or by beta-gamma coincidence spectrometry. With the currently available equipment, detection limits of 0.2 mBq/m 3 can be achieved. An overview on the existing technology and future developments as well as on the interpretation of measurement results is given. (author)

  18. Measurements for monitoring ground motion resulting from mining operations in the Rhenish brown coal district; Messungen zur Ueberwachung von bergbaubedingten Bodenbewegungen im rheinischen Braunkohlenbergbau

    Energy Technology Data Exchange (ETDEWEB)

    Duddek, H; Schaefer, W [Rheinbraun AG, Koeln (Germany)

    1997-12-31

    Coal mining in the Rhenish brown coal district resulted in loose rock slopes with a total height of more than 350 m. Mining operations caused ground motion in open-cast mines, in the slopes and in the region ahead of the face. Internal dumping caused motions of the floors, the overburden tip and te slopes of the open-cast mines. The deformations were measured by different methods, and the evaluations are presented here. As examples, permanent monitoring of a slope using the GEOROBOT measuring system and continuous subsidence measurements in an overburdan dump by means of hydrostatic measuring systems are presented. GEOROBOT ensures quasi-continuous measurements of slope motion with an error of 5-7 mm. Hydrostatic measuring systems on the basis of pressure sensors were developed for measurements of single overburden dump strata and the overburden dump basis during dumping. (orig.) [Deutsch] In den rheinischen Braunkohlentagebauen entstehen Lockergesteinsboeschungen mit Gesamthoehen von mehr als 350 m. Die Gewinnungstaetigkeiten verursachen Entlastungsbewegungen im Tagebau, in den Boeschungen und im Tagebauvorfeld. Die Innenverkippung fuehrt erneut zu Bodenbewegungen im Liegenden, im Kippenkoerper und im Bereich der Tagebauraender. Die auftretenden Deformationen werden mit verschiedenen Messverfahren erfasst, ausgewertet und dargestellt. Beispielhaft werden die permanente Ueberwachung einer Boeschung mittels des automatischen Messsystems GEOROBOT und kontinuierliche Setzungsmessungen in einer Tagebaukippe mit hydrostatischen Messsystemen vorgestellt. Mit GEOROBOT werden quasi kontinuierlich Boeschungsbewegungsmessungen mit einer Genauigkeit von {+-}5 bis 7 mm durchgefuehrt. Auf der Basis von Drucksensoren wurden hydrostatische Messsysteme konzipiert, mit denen Setzungen einzelner Kippscheiben und der Kippenbasis waehrend des Kippenaufbaues ermittelt werden. (orig.)

  19. Measurements for monitoring ground motion resulting from mining operations in the Rhenish brown coal district; Messungen zur Ueberwachung von bergbaubedingten Bodenbewegungen im rheinischen Braunkohlenbergbau

    Energy Technology Data Exchange (ETDEWEB)

    Duddek, H.; Schaefer, W. [Rheinbraun AG, Koeln (Germany)

    1996-12-31

    Coal mining in the Rhenish brown coal district resulted in loose rock slopes with a total height of more than 350 m. Mining operations caused ground motion in open-cast mines, in the slopes and in the region ahead of the face. Internal dumping caused motions of the floors, the overburden tip and te slopes of the open-cast mines. The deformations were measured by different methods, and the evaluations are presented here. As examples, permanent monitoring of a slope using the GEOROBOT measuring system and continuous subsidence measurements in an overburdan dump by means of hydrostatic measuring systems are presented. GEOROBOT ensures quasi-continuous measurements of slope motion with an error of 5-7 mm. Hydrostatic measuring systems on the basis of pressure sensors were developed for measurements of single overburden dump strata and the overburden dump basis during dumping. (orig.) [Deutsch] In den rheinischen Braunkohlentagebauen entstehen Lockergesteinsboeschungen mit Gesamthoehen von mehr als 350 m. Die Gewinnungstaetigkeiten verursachen Entlastungsbewegungen im Tagebau, in den Boeschungen und im Tagebauvorfeld. Die Innenverkippung fuehrt erneut zu Bodenbewegungen im Liegenden, im Kippenkoerper und im Bereich der Tagebauraender. Die auftretenden Deformationen werden mit verschiedenen Messverfahren erfasst, ausgewertet und dargestellt. Beispielhaft werden die permanente Ueberwachung einer Boeschung mittels des automatischen Messsystems GEOROBOT und kontinuierliche Setzungsmessungen in einer Tagebaukippe mit hydrostatischen Messsystemen vorgestellt. Mit GEOROBOT werden quasi kontinuierlich Boeschungsbewegungsmessungen mit einer Genauigkeit von {+-}5 bis 7 mm durchgefuehrt. Auf der Basis von Drucksensoren wurden hydrostatische Messsysteme konzipiert, mit denen Setzungen einzelner Kippscheiben und der Kippenbasis waehrend des Kippenaufbaues ermittelt werden. (orig.)

  20. The international remote monitoring project and implication

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    The future of remote monitoring in International Safeguards system is analyzed. Problems of an update on the International Remote Monitoring Project are considered. The Project allows to remotely transmit safeguards-relevant data directly to IAEA from nuclear facilities worldwide. Description of integrated monitoring system (IMS) is given. A key element of state-of-art of IMS is modular nodal system which accepts information from sensors and provides information to both a data storage unit and a transmitter. Remote Monitoring Systems of Australia and Sweden are presented. 3 figs

  1. Information management system study results. Volume 1: IMS study results

    Science.gov (United States)

    1971-01-01

    The information management system (IMS) special emphasis task was performed as an adjunct to the modular space station study, with the objective of providing extended depth of analysis and design in selected key areas of the information management system. Specific objectives included: (1) in-depth studies of IMS requirements and design approaches; (2) design and fabricate breadboard hardware for demonstration and verification of design concepts; (3) provide a technological base to identify potential design problems and influence long range planning (4) develop hardware and techniques to permit long duration, low cost, manned space operations; (5) support SR&T areas where techniques or equipment are considered inadequate; and (6) permit an overall understanding of the IMS as an integrated component of the space station.

  2. Original models of NGN/IMS-networks surrounded by circuit-switched systems

    OpenAIRE

    Kulikov, Nikolay

    2014-01-01

    On obtaining of the Alexander Graham Bell a patent for invention of the telephone in 1987, the communication system consistently has gone through several evolutionary stages: from analog lines and manual switches to video telephony and IMS architecture. Each of the stages can be described by specific switching systems, data transmission systems and types of transmitted information. After implementation of such solution, it is possible to create a number of access nodes in the Operators IMS-ne...

  3. Support and Maintenance of the International Monitoring System network

    Science.gov (United States)

    Pereira, Jose; Bazarragchaa, Sergelen; Kilgour, Owen; Pretorius, Jacques; Werzi, Robert; Beziat, Guillaume; Hamani, Wacel; Mohammad, Walid; Brely, Natalie

    2014-05-01

    The Monitoring Facilities Support Section of the Provisional Technical Secretariat (PTS) has as its main task to ensure optimal support and maintenance of an array of 321 monitoring stations and 16 radionuclide laboratories distributed worldwide. Raw seismic, infrasonic, hydroacoustic and radionuclide data from these facilities constitutes the basic product delivered by the International Monitoring System (IMS). In the process of maintaining such a wide array of stations of different technologies, the Support Section contributes to ensuring station mission capability. Mission capable data availability according to the IMS requirements should be at least 98% annually (no more than 7 days down time per year per waveform stations - 14 continuous for radionuclide stations) for continuous data sending stations. In this presentation, we will present our case regarding our intervention at stations to address equipment supportability and maintainability, as these are particularly large activities requiring the removal of a substantial part of the station equipment and installation of new equipment. The objective is always to plan these activities while minimizing downtime and continuing to meet all IMS requirements, including those of data availability mentioned above. We postulate that these objectives are better achieved by planning and making use of preventive maintenance, as opposed to "run-to-failure" with associated corrective maintenance. We use two recently upgraded Infrasound Stations (IS39 Palau and IS52 BIOT) as a case study and establish a comparison between these results and several other stations where corrective maintenance was performed, to demonstrate our hypothesis.

  4. QUARTERLY TECHNICAL REPORT FOR IN-MINE (IM) SYSTEM

    International Nuclear Information System (INIS)

    Zvi H. Meiksin

    2001-01-01

    A circuit that had been earlier lab-tested to eliminate multi-antenna interference in the In-mine (IM) system was fabricated, implemented and tested successfully in a system setting. An adaptive, tracking comb-filter for the through-the-earth (TTE) communications system was designed and implemented. This resulted in noticeable noise reduction. Studies for multi-channel transmission have begun

  5. Systeme im Einsatz. Lernmanagement, Kompetenzmanagement und PLE

    NARCIS (Netherlands)

    Kalz, Marco; Schön, Sandra; Lindner, Martin; Roth, Detlev; Baumgartner, Peter

    2011-01-01

    Kalz, M., Schön, S., Lindner, M., Roth, D., & Baumgartner, P. (2011). Systeme im Einsatz. Lernmanagement, Kompetenzmanagement und PLE. In M. Ebner, & S. Schön (Eds.), L3T - Lerhbuch für Lernen und Lehren mit Technologie (pp. 111-118). Graz, Austria: Uni Graz. Available at

  6. Resilience of the IMS system

    DEFF Research Database (Denmark)

    Kamyod, Chayapol; Nielsen, Rasmus Hjorth; Prasad, Neeli R.

    2014-01-01

    The paper focuses on end-to-end resilience analysis of the IMS based network through the principal resilience parameters by using OPNET. The resilience behaviours of communication across multiple IMS domains are investigated at different communication scenarios and compared with previous state......-of-the-art. Moreover, the resilience effects when adding a redundancy of the S-CSCF unit are examined. The results disclose interesting resilience behaviours for long distance communications....

  7. Global R&D through the Intelligent Manufacturing Systems (IMS) program

    Science.gov (United States)

    Huray, Paul G.

    1997-01-01

    The industry-led, international intelligent manufacturing systems (IMS) program provides a special vehicle for joint research and development between government, industry and academia in the United States, Canada, Japan, Australia, and Europe. Since its beginning in 1989, the IMS program has progressed through a feasibility phase which demonstrated that international legal barriers, trade issues, and intellectual property problems could be overcome. The program is constructed to provide higher quality design, customized products, shorter delivery cycles and lower costs. Interactions between partner companies have led to new business opportunities for mutual profit and some claim to have learned strategic information about their international competitors. The IMS program is growing through the participation of hundreds of corporate and university partners who share responsibilities in specific projects and jointly reap benefits for their manufacturing products and processes. The logic for choosing or not choosing the IMS mechanisms will be discussed and R and D projects will be identified.

  8. Resilience in IMS

    DEFF Research Database (Denmark)

    Kamyod, Chayapol; Nielsen, Rasmus Hjorth; Prasad, Neeli R.

    2012-01-01

    ) and supporting always on services. Therefore, not only Quality of Service (QoS) but also resilience is required. In this paper, we attempt to evaluate and analyze end-to-end reliability of the IMS system using a model proposed as a combination of Reliability Block Diagram (RBD) and Markov Reward Models (MRMs......Reliability evaluation of systems has been widely researched for improving system resilience especially in designing processes of a complex system. The convergence of different access networks is possible via IP Multimedia Subsystem (IMS) for development toward Next Generation Networks (NGNs......). The resilience of the IMS architecture is studied by applying 1:1 redundancy at different communication scenarios between end users within and across communication domains. The model analysis provides useful reliability characteristics of the system and can be further applied for system design processes....

  9. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

  10. Robust stator resistance identification of an IM drive using model reference adaptive system

    International Nuclear Information System (INIS)

    Madadi Kojabadi, Hossein; Abarzadeh, Mostafa; Aghaei Farouji, Said

    2013-01-01

    Highlights: ► We estimate the stator resistance and rotor speed of the IM. ► We proposed a new quantity to estimate the speed and stator resistance of IM. ► The proposed algorithm is robust to rotor resistance variations. ► We estimate the IM speed and stator resistance simultaneously to avoid speed error. - Abstract: Model reference adaptive system (MRAS) based robust stator resistance estimator for sensorless induction motor (IM) drive is proposed. The MRAS is formed with a semi-active power quantity. The proposed identification method can be achieved with on-line tuning of the stator resistance with robustness against rotor resistance variations. Stable and efficient estimation of IM speed at low region will be guaranteed by simultaneous identification of IM speed and stator resistance. The stability of proposed stator resistance estimator is checked through Popov’s hyperstability theorem. Simulation and experimental results are given to highlight the feasibility, the simplicity, and the robustness of the proposed method.

  11. Coherent ambient infrasound recorded by the global IMS network

    Science.gov (United States)

    Matoza, R. S.; Landes, M.; Le Pichon, A.; Ceranna, L.; Brown, D.

    2011-12-01

    The International Monitoring System (IMS) includes a global network of infrasound arrays, which is designed to detect atmospheric nuclear explosions anywhere on the planet. The infrasound network also has potential application in detection of natural hazards such as large volcanic explosions and severe weather. Ambient noise recorded by the network includes incoherent wind noise and coherent infrasound. We present a statistical analysis of coherent infrasound recorded by the IMS network. We have applied broadband (0.01 to 5 Hz) array processing systematically to the multi-year IMS historical dataset (2005-present) using an implementation of the Progressive Multi-Channel Correlation (PMCC) algorithm in log-frequency space. We show that IMS arrays consistently record coherent ambient infrasound across the broad frequency range from 0.01 to 5 Hz when wind-noise levels permit. Multi-year averaging of PMCC detection bulletins emphasizes continuous signals such as oceanic microbaroms, as well as persistent transient signals such as repetitive volcanic, surf, or anthropogenic activity (e.g., mining or industrial activity). While many of these continuous or repetitive signals are of interest in their own right, they may dominate IMS array detection bulletins and obscure or complicate detection of specific signals of interest. The new PMCC detection bulletins have numerous further applications, including in volcano and microbarom studies, and in IMS data quality assessment.

  12. General Purpose Data-Driven Monitoring for Space Operations

    Science.gov (United States)

    Iverson, David L.; Martin, Rodney A.; Schwabacher, Mark A.; Spirkovska, Liljana; Taylor, William McCaa; Castle, Joseph P.; Mackey, Ryan M.

    2009-01-01

    As modern space propulsion and exploration systems improve in capability and efficiency, their designs are becoming increasingly sophisticated and complex. Determining the health state of these systems, using traditional parameter limit checking, model-based, or rule-based methods, is becoming more difficult as the number of sensors and component interactions grow. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults or failures. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. The scope of IMS based data-driven monitoring applications continues to expand with current development activities. Successful IMS deployment in the International Space Station (ISS) flight control room to monitor ISS attitude control systems has led to applications in other ISS flight control disciplines, such as thermal control. It has also generated interest in data-driven monitoring capability for Constellation, NASA's program to replace the Space Shuttle with new launch vehicles and spacecraft capable of returning astronauts to the moon, and then on to Mars. Several projects are currently underway to evaluate and mature the IMS technology and complementary tools for use in the Constellation program. These include an experiment on board the Air Force TacSat-3 satellite, and ground systems monitoring for NASA's Ares I-X and Ares I launch vehicles. The TacSat-3 Vehicle System Management (TVSM) project is a software experiment to integrate fault

  13. Unattented mode monitoring of high resolution gamma-ray spectra

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Van Dyck, P.; Debraix, P.

    1991-01-01

    An Isotope Monitoring System (IMS) for unattended spectrum acquisition is described. This consists of a simple low cost flexible software package running on a Compaq 80386 and controlling up to 4 Canberra Packard System 100 multi-channel analyzer (MCA) cards. The IMS permits the independent configuration of each of the 4 MCA cards for different monitoring cycles and for different spectrum acquisition cycles each being based upon different trigger criteria. In this way IMS is able to automatically identify events, time tag them, and acquire and store valid spectra corresponding to those event. An additional feature of IMS permits to run a Multigroup Analysis (MGA) software package for the determination of plutonium isotopic compositions in batch mode. One particular application is discussed which consists of 4 high resolution gamma-ray detector systems connected together to the IMS for unattended spectrum acquisition. The off-line batch mode analysis of the spectra using MGA is also discussed

  14. Reliability in individual monitoring service.

    Science.gov (United States)

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  15. Detection capability of the IMS seismic network based on ambient seismic noise measurements

    Science.gov (United States)

    Gaebler, Peter J.; Ceranna, Lars

    2016-04-01

    All nuclear explosions - on the Earth's surface, underground, underwater or in the atmosphere - are banned by the Comprehensive Nuclear-Test-Ban Treaty (CTBT). As part of this treaty, a verification regime was put into place to detect, locate and characterize nuclear explosion testings at any time, by anyone and everywhere on the Earth. The International Monitoring System (IMS) plays a key role in the verification regime of the CTBT. Out of the different monitoring techniques used in the IMS, the seismic waveform approach is the most effective technology for monitoring nuclear underground testing and to identify and characterize potential nuclear events. This study introduces a method of seismic threshold monitoring to assess an upper magnitude limit of a potential seismic event in a certain given geographical region. The method is based on ambient seismic background noise measurements at the individual IMS seismic stations as well as on global distance correction terms for body wave magnitudes, which are calculated using the seismic reflectivity method. From our investigations we conclude that a global detection threshold of around mb 4.0 can be achieved using only stations from the primary seismic network, a clear latitudinal dependence for the detection threshold can be observed between northern and southern hemisphere. Including the seismic stations being part of the auxiliary seismic IMS network results in a slight improvement of global detection capability. However, including wave arrivals from distances greater than 120 degrees, mainly PKP-wave arrivals, leads to a significant improvement in average global detection capability. In special this leads to an improvement of the detection threshold on the southern hemisphere. We further investigate the dependence of the detection capability on spatial (latitude and longitude) and temporal (time) parameters, as well as on parameters such as source type and percentage of operational IMS stations.

  16. Monitoring by Use of Clusters of Sensor-Data Vectors

    Science.gov (United States)

    Iverson, David L.

    2007-01-01

    The inductive monitoring system (IMS) is a system of computer hardware and software for automated monitoring of the performance, operational condition, physical integrity, and other aspects of the health of a complex engineering system (e.g., an industrial process line or a spacecraft). The input to the IMS consists of streams of digitized readings from sensors in the monitored system. The IMS determines the type and amount of any deviation of the monitored system from a nominal or normal ( healthy ) condition on the basis of a comparison between (1) vectors constructed from the incoming sensor data and (2) corresponding vectors in a database of nominal or normal behavior. The term inductive reflects the use of a process reminiscent of traditional mathematical induction to learn about normal operation and build the nominal-condition database. The IMS offers two major advantages over prior computational monitoring systems: The computational burden of the IMS is significantly smaller, and there is no need for abnormal-condition sensor data for training the IMS to recognize abnormal conditions. The figure schematically depicts the relationships among the computational processes effected by the IMS. Training sensor data are gathered during normal operation of the monitored system, detailed computational simulation of operation of the monitored system, or both. The training data are formed into vectors that are used to generate the database. The vectors in the database are clustered into regions that represent normal or nominal operation. Once the database has been generated, the IMS compares the vectors of incoming sensor data with vectors representative of the clusters. The monitored system is deemed to be operating normally or abnormally, depending on whether the vector of incoming sensor data is or is not, respectively, sufficiently close to one of the clusters. For this purpose, a distance between two vectors is calculated by a suitable metric (e.g., Euclidean

  17. Evaluation of the indenter modulus (IM) method in the international round robin test about the cable condition monitoring

    International Nuclear Information System (INIS)

    Kajimura, Yuusaku

    2016-01-01

    In order to ensure the reliability and safety of nuclear power plants, the diagnosis of cable aging is important. The Institute of Nuclear Safety System (INSS) has been developing the indenter modulus (IM) method for more than a dozen years. Its usefulness was demonstrated in the research project 'Assessment of cable aging for nuclear power plant' by the Japan Nuclear Energy Safety Organization in 2009. Furthermore, INSS participated in the IAEA Coordinated Research Project in 2013 to 2015, measuring and acquiring data of insulation materials of cables and cable jackets with insulation which had been never measured before by INSS. The main results are as follows. (1) The IM method is useful for new materials (for example, crosslinked polyolefins) which had never been measured before by INSS. (2) The IM method is also applicable to evaluation of cable jackets with insulation made of such materials as chlorosulfonated polyethylene. Therefore, the IM method is evaluated to be useful and applicable for most cable materials except those which have a high IM value initially and which have a small change in IM value during aging. (author)

  18. Business-Intelligence-Systeme im Spannungsfeld zwischen Usability und Sicherheit

    OpenAIRE

    Hinck, Thorsten

    2010-01-01

    Business-Intelligence-Systeme stehen im Spannungsfeld zwischen Usability und Sicherheit. Die Gefahren und Sicherheitsmaßnahmen für Informationssysteme werden ermittelt und ökonomisch in Bezug zur Gebrauchstauglichkeit gesetzt. Es entsteht ein Sicherheitsprofil für Business-Intelligence-Systeme. Business-Intelligence-Systems are in tension between Usability and IT-Security. Risks and safety measures of informationsystems are defined and set in (economic) regard to Usability. A security prof...

  19. Data Analysis of Seismic Sequence in Central Italy in 2016 using CTBTO- International Monitoring System

    Science.gov (United States)

    Mumladze, Tea; Wang, Haijun; Graham, Gerhard

    2017-04-01

    The seismic network that forms the International Monitoring System (IMS) of the Comprehensive Nuclear-test-ban Treaty Organization (CTBTO) will ultimately consist of 170 seismic stations (50 primary and 120 auxiliary) in 76 countries around the world. The Network is still under the development, but currently more than 80% of the network is in operation. The objective of seismic monitoring is to detect and locate underground nuclear explosions. However, the data from the IMS also can be widely used for scientific and civil purposes. In this study we present the results of data analysis of the seismic sequence in 2016 in Central Italy. Several hundred earthquakes were recorded for this sequence by the seismic stations of the IMS. All events were accurately located the analysts of the International Data Centre (IDC) of the CTBTO. In this study we will present the epicentral and magnitude distribution, station recordings and teleseismic phases as obtained from the Reviewed Event Bulletin (REB). We will also present a comparison of the database of the IDC with the databases of the European-Mediterranean Seismological Centre (EMSC) and U.S. Geological Survey (USGS). Present work shows that IMS data can be used for earthquake sequence analyses and can play an important role in seismological research.

  20. The Global Communication Infrastructure of the International Monitoring System

    Science.gov (United States)

    Lastowka, L.; Gray, A.; Anichenko, A.

    2007-05-01

    The Global Communications Infrastructure (GCI) employs 6 satellites in various frequency bands distributed around the globe. Communications with the PTS (Provisional Technical Secretariat) in Vienna, Austria are achieved through VSAT technologies, international leased data circuits and Virtual Private Network (VPN) connections over the Internet. To date, 210 independent VSAT circuits have been connected to Vienna as well as special circuits connecting to the Antarctic and to independent sub-networks. Data volumes from all technologies currently reach 8 Gigabytes per day. The first level of support and a 24/7 help desk remains with the GCI contractor, but performance is monitored actively by the PTS/GCI operations team. GCI operations are being progressively introduced into the PTS operations centre. An Operations centre fully integrated with the GCI segment of the IMS network will ensure a more focused response to incidents and will maximize the availability of the IMS network. Existing trouble tickets systems are being merged to ensure the commission manages GCI incidents in the context of the IMS as a whole. A focus on a single source of data for GCI network performance has enabled reporting systems to be developed which allow for improved and automated reports. The contracted availability for each individual virtual circuit is 99.5% and this performance is regularly reviewed on a monthly basis

  1. Implementation of quality standards in an individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, H.; Vartiainen, E

    2001-07-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  2. Implementation of quality standards in an individual monitoring service

    International Nuclear Information System (INIS)

    Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  3. Authentication of data for monitoring a comprehensive test ban treaty

    International Nuclear Information System (INIS)

    Craft, R.L.; Draelos, T.J.

    1996-05-01

    The important issue of data integrity in the CTBT International Monitoring System (IMS) is discussed and a brief tutorial on data authentication techniques is offered. The utilization of data authentication as a solution to the data integrity problem is evaluated. Public key data authentication is recommended for multilateral monitoring regimes such as the CTBT. The ramifications and system considerations of applying data authentication at various locations in the IMS, or not at all, are reviewed in a data surety context. The paper concludes with a recommendation of authenticating data at all critical monitoring stations

  4. An Innovative Approach to the Integrated Management System Development: SIMPRO-IMS Web Based Environment

    Directory of Open Access Journals (Sweden)

    Kristina Zgodavova

    2012-12-01

    Full Text Available The purpose of this paper is to contribute to learning, knowledge creation and knowledge transfer for building organization innovability by integrating the management systems in the SIMPRO-IMS web based environment. The paper content consists of the interpretation of role-play simulation, role-play simulation process description, methodology, and the employment of role-play simulation outcomes, as well as the discussion of the knowledge thus obtained. Primary the model of the SIMPRO-Q education environment has been developed and tested during a period of 15 years in several industrial organizations as well as service organizations such as Higher Education Institution (HEI and Healthcare Organization (HCO. The newest version SIMPRO-IMS has recently been developed to support a need of integration of management systems and information archiving. With the last development, SIMPRO-IMS web based environment, processes of five ISO systems are integrated for parallel development, implementation, auditing, maintaining and leading. SIMPRO-IMS provides management with the apparatus necessary to realize a systematic and verifiable approach to the creation and control of IMS documentation. At the same time contributes to the preservation of organization memory in response to the growing challenges of globalization and digitalization. The research is limited by the complexity of a real system and possible empiric results verification. The results achieved are verified when people really overcome the resistance to change. This can be assessed thoughtfully only after some period of time. Another limitation is presented by measurability of real enhancement achieved in quality, safety and environmentality of production, and business continuity and social responsibility of an organization. Development and progress in the methodology of SIMPRO-IMS web based environment is encoded in upgrading the SIMPRO database by processes of the environmental management

  5. Usability test of the ImPRO, computer-based procedure system

    International Nuclear Information System (INIS)

    Jung, Y.; Lee, J.

    2006-01-01

    ImPRO is a computer based procedure in both flowchart and success logic tree. It is evaluated on the basis of computer based procedure guidelines. It satisfies most requirements such as presentations and functionalities. Besides, SGTR has been performed with ImPRO to evaluate reading comprehension and situation awareness. ImPRO is a software engine which can interpret procedure script language, so that ImPRO is reliable by nature and verified with formal method. One bug, however, had hidden one year after release, but it was fixed. Finally backup paper procedures can be prepared on the same format as VDU in case of ImPRO failure. (authors)

  6. Applying Idea Management System (IMS Approach to Design and Implement a collaborative Environment in Public Service related open Innovation Processes

    Directory of Open Access Journals (Sweden)

    Marco Alessi

    2015-12-01

    Full Text Available Novel ideas are the key ingredients for innovation processes, and Idea Management System (IMS plays a prominent role in managing captured ideas from external stakeholders and internal actors within an Open Innovation process. By considering a specific case study, Lecce-Italy, we have designed and implemented a collaborative environment, which provides an ideal platform for government, citizens, etc. to share ideas and co-create the value of innovative public services in Lecce. In this study the application of IMS with six main steps, including: idea generation, idea improvement, idea selection, refinement, idea implementation, and monitoring, shows that this, remarkably, helps service providers to exploit the intellectual capital and initiatives of the regional stakeholders and citizens and assist service providers to stay in line with the needs of society. Moreover, we have developed two support tools to foster collaboration and transparency: sentiment analysis tool and gamification application.

  7. A cloud-based information repository for bridge monitoring applications

    Science.gov (United States)

    Jeong, Seongwoon; Zhang, Yilan; Hou, Rui; Lynch, Jerome P.; Sohn, Hoon; Law, Kincho H.

    2016-04-01

    This paper describes an information repository to support bridge monitoring applications on a cloud computing platform. Bridge monitoring, with instrumentation of sensors in particular, collects significant amount of data. In addition to sensor data, a wide variety of information such as bridge geometry, analysis model and sensor description need to be stored. Data management plays an important role to facilitate data utilization and data sharing. While bridge information modeling (BrIM) technologies and standards have been proposed and they provide a means to enable integration and facilitate interoperability, current BrIM standards support mostly the information about bridge geometry. In this study, we extend the BrIM schema to include analysis models and sensor information. Specifically, using the OpenBrIM standards as the base, we draw on CSI Bridge, a commercial software widely used for bridge analysis and design, and SensorML, a standard schema for sensor definition, to define the data entities necessary for bridge monitoring applications. NoSQL database systems are employed for data repository. Cloud service infrastructure is deployed to enhance scalability, flexibility and accessibility of the data management system. The data model and systems are tested using the bridge model and the sensor data collected at the Telegraph Road Bridge, Monroe, Michigan.

  8. Automated detection and cataloging of global explosive volcanism using the International Monitoring System infrasound network

    Science.gov (United States)

    Matoza, Robin S.; Green, David N.; Le Pichon, Alexis; Shearer, Peter M.; Fee, David; Mialle, Pierrick; Ceranna, Lars

    2017-04-01

    We experiment with a new method to search systematically through multiyear data from the International Monitoring System (IMS) infrasound network to identify explosive volcanic eruption signals originating anywhere on Earth. Detecting, quantifying, and cataloging the global occurrence of explosive volcanism helps toward several goals in Earth sciences and has direct applications in volcanic hazard mitigation. We combine infrasound signal association across multiple stations with source location using a brute-force, grid-search, cross-bearings approach. The algorithm corrects for a background prior rate of coherent unwanted infrasound signals (clutter) in a global grid, without needing to screen array processing detection lists from individual stations prior to association. We develop the algorithm using case studies of explosive eruptions: 2008 Kasatochi, Alaska; 2009 Sarychev Peak, Kurile Islands; and 2010 Eyjafjallajökull, Iceland. We apply the method to global IMS infrasound data from 2005-2010 to construct a preliminary acoustic catalog that emphasizes sustained explosive volcanic activity (long-duration signals or sequences of impulsive transients lasting hours to days). This work represents a step toward the goal of integrating IMS infrasound data products into global volcanic eruption early warning and notification systems. Additionally, a better understanding of volcanic signal detection and location with the IMS helps improve operational event detection, discrimination, and association capabilities.

  9. The Global Detection Capability of the IMS Seismic Network in 2013 Inferred from Ambient Seismic Noise Measurements

    Science.gov (United States)

    Gaebler, P. J.; Ceranna, L.

    2016-12-01

    All nuclear explosions - on the Earth's surface, underground, underwater or in the atmosphere - are banned by the Comprehensive Nuclear-Test-Ban Treaty (CTBT). As part of this treaty, a verification regime was put into place to detect, locate and characterize nuclear explosion testings at any time, by anyone and everywhere on the Earth. The International Monitoring System (IMS) plays a key role in the verification regime of the CTBT. Out of the different monitoring techniques used in the IMS, the seismic waveform approach is the most effective technology for monitoring nuclear underground testing and to identify and characterize potential nuclear events. This study introduces a method of seismic threshold monitoring to assess an upper magnitude limit of a potential seismic event in a certain given geographical region. The method is based on ambient seismic background noise measurements at the individual IMS seismic stations as well as on global distance correction terms for body wave magnitudes, which are calculated using the seismic reflectivity method. From our investigations we conclude that a global detection threshold of around mb 4.0 can be achieved using only stations from the primary seismic network, a clear latitudinal dependence for the detection thresholdcan be observed between northern and southern hemisphere. Including the seismic stations being part of the auxiliary seismic IMS network results in a slight improvement of global detection capability. However, including wave arrivals from distances greater than 120 degrees, mainly PKP-wave arrivals, leads to a significant improvement in average global detection capability. In special this leads to an improvement of the detection threshold on the southern hemisphere. We further investigate the dependence of the detection capability on spatial (latitude and longitude) and temporal (time) parameters, as well as on parameters such as source type and percentage of operational IMS stations.

  10. Engineering and development projects for the sustainment and enhancement of the IMS infrasound network

    Science.gov (United States)

    Marty, J.; Martysevich, P.; Kramer, A.; Haralabus, G.

    2012-04-01

    The Provisional Technical Secretariat (PTS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) has a continuous interest in enhancing its capability in infrasound source localization and characterization. This capability is based on the processing of data recorded by the infrasound network of the International Monitoring System (IMS). This infrasound network consists of sixty stations, among which forty-five are already certified and continuously transmit data to the International Data Center (IDC) in Vienna, Austria. Each infrasound station is composed of an array of infrasound sensors capable of measuring micro-pressure changes produced at ground level by infrasonic waves. It is the responsibility of the Engineering and Development Section of the IMS Division to ensure the highest quality for IMS infrasound data. This includes the design of robust and reliable infrasound stations, the use of accurate and calibrated infrasound measuring chains, the installation of efficient wind noise reduction systems and the implementation of quality-control tools. The purpose of this paper is to present ongoing PTS infrasound engineering and development projects related to the testing and validation of wind noise reduction system models, the implementation of infrasound data QC tools, the definition of guidelines for the design of IMS power supply systems and the development of a portable infrasound calibrator and of field kits for site survey and certification.

  11. Maintenance and Logistics Support for the International Monitoring System Network of the CTBTO

    Science.gov (United States)

    Haslinger, F.; Brely, N.; Akrawy, M.

    2007-05-01

    The global network of the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), once completed, will consist of 321 monitoring facilities of four different technologies: hydroacoustic, seismic, infrasonic, and radionuclide. As of today, about 65% of the installations are completed and contribute data to the products issued by the International Data Centre (IDC) of the CTBTO. In order to accomplish the task to reliably collect evidence for any potential nuclear test explosion anywhere on the planet, all stations are required to perform to very high data availability requirements (at least 98% data availability over a 12-month period). To enable reaching this requirement, a three-layer concept has been developed to allow efficient support of the IMS stations: Operations, Maintenance and Logistics, and Engineering. Within this concept Maintenance and Logistics provide second level support of the stations, whereby problems arising at the station are assigned through the IMS ticket system to Maintenance if they cannot be resolved on the Operations level. Maintenance will then activate the required resources to appropriately address and ultimately resolve the problem. These resources may be equipment support contracts, other third party contracts, or the dispatch of a maintenance team. Engineering Support will be activated if the problem requires redesign of the station or after catastrophic failures when a total rebuild of a station may be necessary. In this model, Logistics Support is responsible for parts replenishment and support contract management. Logistics Support also collects and analyzes relevant failure mode and effect information, develops supportability models, and has the responsibility for document management, obsolescence, risk & quality, and configuration management, which are key elements for efficient station support. Maintenance Support in addition is responsible for maintenance strategies, for

  12. E2eUberIM

    DEFF Research Database (Denmark)

    Wac, Katarzyna; Cummings, Mark; Dey, Jayanta

    2016-01-01

    , high-quality services, we propose an innovative end-to-end service management framework called e2eUberIM. This framework contains a scalable, flexible, and volatile information model (UberIM) and a real-time, "organic" communication and storage process (e2eUber). It leverages the proprietary interfaces...... of different vendors, enabling the resulting enhanced operations system environment to automatically and in real-time optimize operational overhead while maximizing the user experience, and quickly field new innovative, composed "any-services" (XaaS). We document the e2eUberIM requirements and its design...

  13. Analysis of recordings from underwater controlled sources in the Pacific Ocean received by the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO)

    Science.gov (United States)

    Yamada, Tomoaki; Zampolli, Mario; Haralabus, Georgios; Heaney, Kevin; Prior, Mark; Isse, Takeshi

    2016-04-01

    Controlled impulsive scientific underwater sound sources in the Northwestern Pacific were observed at two IMS hydroacoustic stations in the Pacific Ocean. Although these experiments were conducted with the aim of studying the physical properties of the plate boundaries inside the Earth, they are also suitable for the investigation of long range underwater acoustic detections. In spite of the fact that the energy of these controlled impulsive scientific sources is significantly smaller than that of nuclear explosions, the signals were obtained by IMS hydrophone stations thousands of kilometres away and also by distant ocean bottom instruments operated by various Institutes, such as the Earthquake Research Institute, University of Tokyo. These experiments provide calibrated (yield, time, location) long-range acoustic transmissions, which enable one to examine the physics of long-range acoustic propagation and to verify the capabilities of the CTBTO IMS network to detect even small explosions.The two IMS stations used are H03 (Juan Fernandez Island, Chile) off the coast of Chile in the Southeastern Pacific and H11 (Wake Island, USA) in the Western Pacific. Both stations consist of two triplets of hydrophones in the SOFAR channel, which monitor the oceans for signs of nuclear explosions. H03 detected low-yield explosions above flat terrain at distances of 15,000 km across the Pacific as well as explosions above the landward slope off the coast of Japan at distances above 16,000 km across the Pacific. These records showed that source signatures, such as short duration and bubble pulses, were preserved over the long propagation distances. It was found that the observed maximum amplitudes from each source exhibit order of magnitude variations even when the yield and detonation depth are the same. The experimental data and transmission loss simulations suggest that bathymetric features around the sources and between the sources and the receivers are the main causes for

  14. A study on a systematic approach of verification and validation of a computerized procedure system: ImPRO

    International Nuclear Information System (INIS)

    Qin, Wei; Seong, Poong Hyun

    2003-01-01

    Paper Based Procedure (PBP) and Computerized Procedure System (CPS) are studied to demonstrate that it is necessary to develop CPS in NPP I and C system. Computerized procedure system is actually a software system. All the desired and undesired properties of a software system can be described and evaluated as software qualities. Generally, software qualities can be categorized into product quality and process quality. In order to achieve product quality, the process quality of a software system should also be considered and achieved. Characteristics of CPS will be described to analyse the product and process of an example CPS: ImPRO. At the same time, several main product and process issues will be analysed from Verification and Validation (V and V) point of view. It is concluded and suggested that V and V activities can also be regarded as software development process, this point of view then is applied to the V and V activities of ImPRO as a systematic approach of V and V of ImPRO. To support and realize this approach, suitable testing technologies and testing strategies are suggested

  15. IMS Application Developer's Handbook Creating and Deploying Innovative IMS Applications

    CERN Document Server

    Noldus, Rogier; Mulligan, Catherine; Fikouras, Ioannis; Ryde, Anders; Stille, Mats

    2011-01-01

    IMS Application Developer Handbook will give a hands-on view of exactly what needs to be done by IMS application developers to write an application and take it "live" on an operator's network. It will offer practical guidance on building innovative applications using the features and capabilities of the IMS network, show how the rapidly changing development environment is impacting on the business models employed in the industry and how existing network solutions can be moved towards IMS. The book will also elaborate on how IMS applies basic VoIP principles and techniques to realise a true mul

  16. Economic management system at the im. Abakumova mine

    Energy Technology Data Exchange (ETDEWEB)

    Martynenko, V.F. (Shakhta im. Abakumova (Ukraine))

    1992-08-01

    Decribes new methods of settling accounts between mine departments, and methods of paying wages introduced in the im. Abakumova mine. Internal banknotes were introduced in 1991. Ways of clearing the cost of materials, depreciation and repair work are explained. Claims of mine departments are settled by arbitration committees. It was found that the new system of financial self-dependence of mine departments prevented downtime from occurring. Losses of coal reserves were reduced in 1991 by 28% compared to 1990. In the first quarter of 1992, labor efficiency increased by 6% compared to the first quarter in 1991.

  17. Development of an Intelligent Monitoring System for Geological Carbon Sequestration (GCS) Systems

    Science.gov (United States)

    Sun, A. Y.; Jeong, H.; Xu, W.; Hovorka, S. D.; Zhu, T.; Templeton, T.; Arctur, D. K.

    2016-12-01

    To provide stakeholders timely evidence that GCS repositories are operating safely and efficiently requires integrated monitoring to assess the performance of the storage reservoir as the CO2 plume moves within it. As a result, GCS projects can be data intensive, as a result of proliferation of digital instrumentation and smart-sensing technologies. GCS projects are also resource intensive, often requiring multidisciplinary teams performing different monitoring, verification, and accounting (MVA) tasks throughout the lifecycle of a project to ensure secure containment of injected CO2. How to correlate anomaly detected by a certain sensor to events observed by other devices to verify leakage incidents? How to optimally allocate resources for task-oriented monitoring if reservoir integrity is in question? These are issues that warrant further investigation before real integration can take place. In this work, we are building a web-based, data integration, assimilation, and learning framework for geologic carbon sequestration projects (DIAL-GCS). DIAL-GCS will be an intelligent monitoring system (IMS) for automating GCS closed-loop management by leveraging recent developments in high-throughput database, complex event processing, data assimilation, and machine learning technologies. Results will be demonstrated using realistic data and model derived from a GCS site.

  18. IMS applications analysis

    Energy Technology Data Exchange (ETDEWEB)

    RODACY,PHILIP J.; REBER,STEPHEN D.; SIMONSON,ROBERT J.; HANCE,BRADLEY G.

    2000-03-01

    This report examines the market potential of a miniature, hand-held Ion Mobility Spectrometer. Military and civilian markets are discussed, as well as applications in a variety of diverse fields. The strengths and weaknesses of competing technologies are discussed. An extensive Ion Mobility Spectrometry (IMS) bibliography is included. The conclusions drawn from this study are: (1) There are a number of competing technologies that are capable of detecting explosives, drugs, biological, or chemical agents. The IMS system currently represents the best available compromise regarding sensitivity, specificity, and portability. (2) The military market is not as large as the commercial market, but the military services are more likely to invest R and D funds in the system. (3) Military applications should be addressed before commercial applications are addressed. (4) There is potentially a large commercial market for rugged, hand-held Ion Mobility Spectrometer systems. Commercial users typically do not invest R and D funds in this type of equipment rather, they wait for off-the-shelf availability.

  19. Managing P2P services via the IMS

    NARCIS (Netherlands)

    Liotta, A.; Lin, L.

    2007-01-01

    The key aim of our work was to illustrate the benefits and means to deploy P2P services via the IMS. Having demonstrated the technical viability of P2P-IMS we have also found a way to add a new management dimension to existing P2P systems. P2P-IMS comes with a natural "data management" mechanism,

  20. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  1. I'm a Map, I'm a Green Tree

    Science.gov (United States)

    Anderson, Daniel

    2010-01-01

    I'm talking about the ways we represent ourselves and our world. I've put some thoughts on the topic together here--a gathering that enacts new media creating and takes up conceptual layers like metaphors, models, and composing. The primary sources are videos from the Get a Mac campaign, aka I'm a Mac; I'm a PC ads. Posthuman concepts blending…

  2. SolarBau:MONITOR - energy efficiency and solar energy use in non-domestic buildings - concepts and buildings 2000; SolarBau:MONITOR - Energieeffizienz und Solarenergienutzung im Nichtwohnungsbau - Konzepte und Bauten. Journal 2000

    Energy Technology Data Exchange (ETDEWEB)

    Voss, K. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany). Gruppe Solares Bauen; Loehnert, G. [Solidar Planungsgesellschaft Architekten und Ingenieure, Berlin (Germany); Wagner, A. [Karlsruhe Univ. (T.H.) (Germany). Fakultaet fuer Architektur

    2001-07-01

    The projecting experience and performance data of many demonstration projects are presented here. The buildings described are office buildings, administrative buildings and industrial buildings whose architecture and energy concepts vary considerably. The text is supplemented by many pictures and illustration. The subject matter is presented in a concise and practically oriented manner. [German] Im Journal 2000 des wissenschaftlichen Begleitforschungsprojekts SolarBau: MONITOR sind die Planungserfahrungen und Betriebsergebnisse aus vielen Demonstrationsprojekten zusammengestellt. Die Buero-, Verwaltungs- und Gewerbegebaeude (d.h. Nichtwohnungsbau) haben sehr verschiedene Gebaeude- und Energiekonzepte. Gerade deshalb ist es interessant, wie diese im Journal 2000 unter den Aspekten wie 'Tageslichtnutzung', 'Waermeschutz', 'Kuehlung', 'Elektrizitaet', 'Solartechnik' miteinander verglichen werden. Die graphisch gut gestaltete Darstellung auf 80 Seiten wird unterstuetzt durch viele Fotos und Abbildungen und gewinnt durch die praxisnahe Aufbereitung, die in Zusammenarbeit mit den Planungsteams erfolgt ist. (orig.)

  3. Global Monitoring of the CTBT: Progress, Capabilities and Plans (Invited)

    Science.gov (United States)

    Zerbo, L.

    2013-12-01

    The Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), established in 1996, is tasked with building up the verification regime of the CTBT. The regime includes a global system for monitoring the earth, the oceans and the atmosphere for nuclear tests, and an on-site inspection (OSI) capability. More than 80% of the 337 facilities of the International Monitoring System (IMS) have been installed and are sending data to the International Data Centre (IDC) in Vienna, Austria for processing. These IMS data along with IDC processed and reviewed products are available to all States that have signed the Treaty. Concurrent with the build-up of the global monitoring networks, near-field geophysical methods are being developed and tested for OSIs. The monitoring system is currently operating in a provisional mode, as the Treaty has not yet entered into force. Progress in installing and operating the IMS and the IDC and in building up an OSI capability will be described. The capabilities of the monitoring networks have progressively improved as stations are added to the IMS and IDC processing techniques refined. Detection thresholds for seismic, hydroacoustic, infrasound and radionuclide events have been measured and in general are equal to or lower than the predictions used during the Treaty negotiations. The measurements have led to improved models and tools that allow more accurate predictions of future capabilities and network performance under any configuration. Unplanned tests of the monitoring network occurred when the DPRK announced nuclear tests in 2006, 2009, and 2013. All three tests were well above the detection threshold and easily detected and located by the seismic monitoring network. In addition, noble gas consistent with the nuclear tests in 2006 and 2013 (according to atmospheric transport models) was detected by stations in the network. On-site inspections of these tests were not conducted as the Treaty has not entered

  4. 24-Dimensional Modulation Formats for 100 Gbit/s IM-DD Transmission Systems Using 850 nm Single-Mode VCSEL

    DEFF Research Database (Denmark)

    Lu, Xiaofeng; Lyubopytov, Vladimir; Tafur Monroy, Idelfonso

    2017-01-01

    Twenty-four dimensional modulation format with 2 bit/symbol spectrum efficiency is proposed and investigated in an up to 100 Gbit/s VCSEL-based IM-DD transmission system with respect to the channel bandwidth and the power budget.......Twenty-four dimensional modulation format with 2 bit/symbol spectrum efficiency is proposed and investigated in an up to 100 Gbit/s VCSEL-based IM-DD transmission system with respect to the channel bandwidth and the power budget....

  5. Using barometric time series of the IMS infrasound network for a global analysis of thermally induced atmospheric tides

    Science.gov (United States)

    Hupe, Patrick; Ceranna, Lars; Pilger, Christoph

    2018-04-01

    The International Monitoring System (IMS) has been established to monitor compliance with the Comprehensive Nuclear-Test-Ban Treaty and comprises four technologies, one of which is infrasound. When fully established, the IMS infrasound network consists of 60 sites uniformly distributed around the globe. Besides its primary purpose of determining explosions in the atmosphere, the recorded data reveal information on other anthropogenic and natural infrasound sources. Furthermore, the almost continuous multi-year recordings of differential and absolute air pressure allow for analysing the atmospheric conditions. In this paper, spectral analysis tools are applied to derive atmospheric dynamics from barometric time series. Based on the solar atmospheric tides, a methodology for performing geographic and temporal variability analyses is presented, which is supposed to serve for upcoming studies related to atmospheric dynamics. The surplus value of using the IMS infrasound network data for such purposes is demonstrated by comparing the findings on the thermal tides with previous studies and the Modern-Era Retrospective analysis for Research and Applications Version 2 (MERRA-2), which represents the solar tides well in its surface pressure fields. Absolute air pressure recordings reveal geographical characteristics of atmospheric tides related to the solar day and even to the lunar day. We therefore claim the chosen methodology of using the IMS infrasound network to be applicable for global and temporal studies on specific atmospheric dynamics. Given the accuracy and high temporal resolution of the barometric data from the IMS infrasound network, interactions with gravity waves and planetary waves can be examined in future for refining the knowledge of atmospheric dynamics, e.g. the origin of tidal harmonics up to 9 cycles per day as found in the barometric data sets. Data assimilation in empirical models of solar tides would be a valuable application of the IMS infrasound

  6. IMS2 – An integrated medical software system for early lung cancer detection using ion mobility spectrometry data of human breath

    Directory of Open Access Journals (Sweden)

    Baumbach Jan

    2007-12-01

    Full Text Available IMS2 is an Integrated Medical Software system for the analysis of Ion Mobility Spectrometry (IMS data. It assists medical staff with the following IMS data processing steps: acquisition, visualization, classification, and annotation. IMS2 provides data analysis and interpretation features on the one hand, and also helps to improve the classification by increasing the number of the pre-classified datasets on the other hand. It is designed to facilitate early detection of lung cancer, one of the most common cancer types with one million deaths each year around the world.

  7. Probing slowly exchanging protein systems via {sup 13}C{sup {alpha}}-CEST: monitoring folding of the Im7 protein

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Alexandar L.; Bouvignies, Guillaume; Kay, Lewis E., E-mail: kay@pound.med.utoronto.ca [University of Toronto, Departments of Molecular Genetics, Biochemistry and Chemistry (Canada)

    2013-03-15

    A {sup 13}C{sup {alpha}} chemical exchange saturation transfer based experiment is presented for the study of protein systems undergoing slow interconversion between an 'observable' ground state and one or more 'invisible' excited states. Here a labeling strategy whereby [2-{sup 13}C]-glucose is the sole carbon source is exploited, producing proteins with {sup 13}C at the C{sup {alpha}} position, while the majority of residues remain unlabeled at CO or C{sup {beta}}. The new experiment is demonstrated with an application to the folding reaction of the Im7 protein that involves an on-pathway excited state. The obtained excited state {sup 13}C{sup {alpha}} chemical shifts are cross validated by comparison to values extracted from analysis of CPMG relaxation dispersion profiles, establishing the utility of the methodology.

  8. Development of a monitor system for gas based detectors and measurement of electron attachment in the chamber gas; Aufbau eines Monitorsystems fuer gasbasierte Detektoren und Messung der Elektronenanlagerung im Kammergas

    Energy Technology Data Exchange (ETDEWEB)

    Linzmaier, Diana

    2009-01-15

    In the framework of an international collaboration a new electron-positron linear accelerator (ILC) with a c. m. energy up to 500 GeV is planned. For the International Large Detector Concept (ILD) a time projection chamber (TPC) shall perform precise measurements of the particle tracks. In order to fulfil the high requirements on the resolution, a microstructure gas-amplification system is used for read-out. For research and development of the detector principle for the application at the ILC at DESY a large TPC prototype is developed. For the operation of the detector it is necessary to monitor its state and especially that of the measurement gas. For this purpose in the framework of this thesis a slow control system is built, which shall make possible for the different collaboration partners to operate the prototype and to integrate the slow control data into their measurement. For this with an object-oriented control system a graphic user interface was created, which makes an overview over the applied measurement devices and a driving allows. Furthermore the influence of impurities of the gas mixture by oxygen was studied. For this with a small TPC prototype measurements of the electron attachment coefficient at different oxygen concentrations were performed with a magnetic flux density of 4 T. From the amplitude of the measurement signal a rate for the electron attachment could be determined. The values obtained for this agree sufficiently in comparison with literature values. [German] Im Rahmen einer internationalen Kollaboration ist ein neuer Elektronen-Positronen-Linearbeschleuniger (ILC) mit einer Schwerpunktsenergie bis zu 500 GeV geplant. Fuer das International Large Detector Concept (ILD) soll eine Zeitprojektionskammer (TPC) praezise Vermessungen der Teilchenspuren durchfuehren. Um die hohen Anforderungen an die Aufloesung zu erfuellen, wird ein Mikrostruktur-Gasverstaerkungssystem zur Auslese verwendet. Zur Erforschung und Entwicklung des

  9. Effectiveness of onsite wastewater reuse system in reducing bacterial contaminants measured with human-specific IMS/ATP and qPCR.

    Science.gov (United States)

    Agidi, Senyo; Vedachalam, Sridhar; Mancl, Karen; Lee, Jiyoung

    2013-01-30

    Water shortages and the drive to recycle is increasing interest in reuse of reclaimed wastewater. Timely and cost-effective ways to detect fecal pollutants prior to reuse increases confidence of residents and neighbors concerned about reuse of reclaimed wastewater. The on-site wastewater treatment and reuse systems (OWTRS) used in this study include a septic tank, peat bioreactor, ClO(2) disinfection and land spray irrigation system. Bacteroides fragilis, Escherichia coli and Enterococcus spp., were tested with immunomagnetic separation/ATP bioluminescence (IMS/ATP), qPCR and culture-based methods. The results displayed a 2-log reduction in fecal bacteria in the peat bioreactor and a 5-log reduction following chloride dioxide disinfection. The fecal bacteria levels measured by IMS/ATP correlated with qPCR results: HuBac 16S (R(2) = 0.903), Bf-group 16S (R(2) = 0.956), gyrB (R(2) = 0.673), and Ent 23S (R(2) = 0.724). This is the first study in which the newly developed human-specific IMS/ATP and previously developed IMS/ATP were applied for determining OWTRS efficiency. Results of the study revealed that IMS/ATP is a timely and cost-effective way to detect fecal contaminants, and results were validated with qPCR and culture based methods. The new IMS/ATP can also be applied broadly in the detection of human-originated fecal contamination. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Seismic Calibration of Group 1 IMS Stations in Eastern Asia for Improved IDC Event Location

    National Research Council Canada - National Science Library

    Murphy, J. R; Rodi, W. L; Johnson, M; Sultanov, J. D; Bennett, T. J; Toksoz, M. N; Ovtchinnikov, V; Barker, B. W; Rosca, A. M; Shchukin, Y

    2006-01-01

    .... In order to establish a robust nuclear test monitoring capability, it is necessary to calibrate the IMS seismic stations used in monitoring, to account for systematic deviations from the nominal travel time curves...

  11. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Energy Technology Data Exchange (ETDEWEB)

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  12. Organisationsprobleme im Ökomarketing

    OpenAIRE

    Dienel, Wolfram

    2000-01-01

    Organisationsprobleme im Ökomarketing - eine transaktionskostentheoretische Analyse im Absatzkanal konventioneller Lebensmittelhandel Die im Vergleich zum großen Nachfragepotential zögerliche Entwicklung des Ökomarkts in Deutschland ist auf Organisationsprobleme zurückzuführen. Die Organisationsprobleme behindern insbesondere die großskalige Ökomarkterschließung über die konventionellen Supermarktketten, erschweren aber auch die Effizienzsteigerung im kleiner strukturierten alternativen N...

  13. Developing an effective IM/IT strategy.

    Science.gov (United States)

    Kramer, Sarah; Walker, Joanne; Falk, Will

    2009-01-01

    Healthcare organizations and systems around the world lag far behind banking, manufacturing, travel and other industries in their use of information management/information technology (IM/IT) to deliver high-quality products and services. Across Canada, healthcare organizations, as well as governments, understand that information and information technology are needed to deliver quality care and to sustain our publicly funded health system. However, insufficient funding, few experienced resources, lack of strong leadership and absence of clear business/clinical rationale have restricted innovation and advancement in the use of IM/IT to improve healthcare delivery and patient outcomes.

  14. The CTBT Verification Regime: Monitoring the Earth for nuclear explosions

    International Nuclear Information System (INIS)

    2011-03-01

    The Comprehensive nuclear-Test-Ban Treaty (CTBT) bans all nuclear weapon tests. Its unique verification regime is designed to detect nuclear explosions anywhere on the planet - in the oceans, underground and in the atmosphere. once complete, the international Monitoring system (iMs) will consist of 337 facilities located in 89 countries around the globe. The iMs is currently operating in test mode so that data are already transmitted for analysis from monitoring facilities to the international Data Centre (iDC) at the headquarters of the preparatory Commission for the Comprehensive nuclear-Test-Ban Treaty Organization (CTBTO) in Vienna. Data and analysis results are shared with Member states.

  15. The German Energy Monitor. Impact of advertising, competitive account management and customers' readiness to change supplier, as shown by a national benchmark system; Der deutsche Energiemonitor. Werbewirkung, Kundenbindung und Wechselbereitschaft im Spiegel eines nationalen Benchmarksystems

    Energy Technology Data Exchange (ETDEWEB)

    Keller, B.; Matzke, S.; Voss, M. [TNS-EMNID, Bielefeld (Germany)

    1999-09-01

    The article describes the German Energy Monitor published by the EMNID-Institut as a source of statistical information and an effective tool for market research and marketing strategy decisions of enterprise in the energy sector, including to a growing extent regional or local, municipal energy supply companies. (orig./CB) [German] Der Marktforschung messen spaetestens seit der Liberalisierung im Energiesektor immer mehr EVU eine immer groessere Bedeutung fuer das eigene Marketing bei. Angesichts veraenderter Rahmenbedingungen wird vielerorts erkannt, dass dementsprechend Marktforschungsaufgaben zunehmend komplexer werden. Selbst Anbieter auf der geographisch kleinsten Ebene erkennen die Notwendigkeit wachsender Marktforschungsaktivitaeten. Marktforschung wird heute nicht nur von den grossen Verbundunternehmen, sondern auch von regionalen und lokalen Versorgern durchgefuehrt. Energiemonitoring wird so zu einer immer bedeutenderen Aufgabe fuer das Marketing im Energiesektor. Der deutsche Energiemonitor des EMNID-Instituts ist eine Zugangsmoeglichkeit zu den immer wichtiger werdenden Verbraucherdaten. (orig.)

  16. Converter Compressor Building, SWMU 089, Hot Spot Areas 1, 2, and 5 Operations, Maintenance, and Monitoring Report, Kennedy Space Center, Florida

    Science.gov (United States)

    Wilson, Deborah M.

    2015-01-01

    This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from operation of the air sparging (AS) interim measure (IM) for Hot Spot (HS) Areas 1, 2, and 5 at the Converter Compressor Building (CCB) located at Kennedy Space Center (KSC), Florida. The objective of the IM at CCB HS Areas 1, 2, and 5 is to decrease concentrations of volatile organic compounds (VOCs) in groundwater in the treatment zones via AS to levels that will enable a transition to a monitored natural attenuation (MNA) phase. This OMMR presents system operations and maintenance (O&M) information and performance monitoring results since full-scale O&M began in June 2014 (2 months after initial system startup in April 2014), including quarterly performance monitoring events in July and October 2014 and January and May 2015. Based on the results to date, the AS system is operating as designed and is meeting the performance criteria and IM objective. The performance monitoring network is adequately constructed for assessment of IM performance at CCB HS Areas 1, 2, and 5. At the March 2014 KSC Remediation Team (KSCRT) Meeting, team consensus was reached for the design prepared for expansion of the system to treat the HS 4 area, and at the November 2014 KSCRT Meeting, team consensus was reached that HS 3 was adequately delineated horizontally and vertically and for selection of AS for the remedial approach for HS 3. At the July 2015 KSCRT meeting, team consensus was reached to continue IM operations in all zones until HSs 3 and 4 is operational, once HS 3 and 4 zones are operational discontinue operations in HS 1, 2, and 5 zones where concentrations are less than GCTLs to observe whether rebounding conditions occur. Team consensus was also reached to continue quarterly performance monitoring to determine whether operational zones achieve GCTLs and to continue annual IGWM of CCB-MW0012, CCBMW0013, and CCB-MW0056, located south of the treatment area. The

  17. Monitoring with satellite data in opencast workings in the Lower Lusatian brown coal mining area; Monitoring mit Satellitendaten fuer Tagebaugebiete im Niederlausitzer Braunkohlenrevier

    Energy Technology Data Exchange (ETDEWEB)

    Pilarski, M. [uve Fernerkundungszentrum GmbH, Potsdam (Germany); Tischer, U. [Garten- und Landschaftsbau BUL-B-AUMANN GmbH, Senftenberg (Germany)

    2000-02-01

    The paper presents investigations carried out to develop a suitable tool for the determination, analysis and assessment of long-term changes in natural conditions in the region of opencast workings in the Lower Lusation brown coal mining area (Saxony, Germany). It is established that changes in nature can be defined with the aid of multitemporal data sets and remote sensing methods, using GIS (Geographical Information System) techniques. Seven Landsat-TM data sets for the period from 1985 to 1996, which were radiometrically calibrated and georeferenced, were selected to study the relationship between remotely sensed data and biotic and abiotic factors, such as habitat classification as well as soil types or ground-water levels. For this purpose the vegetation index NDVI (Normalized Differential Vegetation Index) was derived from the satellite data. Different trends estimate for the local and regional extent of changes, which are indicated by the NDVI variations, are discussed with regard to their cause and effect relations. (orig.) [German] Mit dem aus Satellitendaten abgeleiteten Vegetationsmerkmal NDVI koennen flaechendeckend Biotope charakterisiert werden. Diese als spektraler Vegetationszustand ermittelten Werte gestatten es, die interne Vegetationsstruktur einer raeumlichen Einheit und deren zeitliche Veraenderung festzustellen. Es konnte gezeigt werden, dass die Hoehe der Vitalitaetswerte in direktem Zusammenhang zu Typen von Biotopen und deren unterschiedlichen wesentlichen Standortbedingungen Boden und oberflaechennahe bindige Bildungen steht. Weiterhin wurde gezeigt, dass dieses Vegetationsmerkmal auch die langfristige generelle Wasserversorgung, repraesentiert durch monatliche Mittelwerte der Niederschlaege, widerspiegelt. Dieser Vegetationszustand ist deshalb in mehrfacher Hinsicht als ein Parameter fuer ein auf Biotope gerichtetes Monitoring geeignet. Er gestattet interne Veraenderungen von Biotopen festzustellen und er dient der Ermittlung eines

  18. Energy pole system in the new building of the PAGO AG, Grabs (CH); Energiepfahlsystem im Neubau der PAGO AG, Grabs (CH)

    Energy Technology Data Exchange (ETDEWEB)

    Scheuss, U [NDS-HTL, Ingenieurbuero Lippuner und Partner AG, Grabs (Switzerland)

    1997-12-01

    With 570 concrete poles and 80 km of tubes, 100,000 m{sup 3} of ground serve as a cold and heat storage resservoir for a building. The building houses a printing shop, which needs cooling in summer and heating in winter. The energy pole system can be used as a dual system for heating and cooling in both seasons. The project is a pilot project of the BWE (Swiss General Office for Utilities and Power Supply), who also started an extensive accompanying measurig campaign. The results during the first year of operation were very positive, and the performance of the energy pole system was up to expectations. (orig.) [Deutsch] Mittelpunkt der PAGO-Energietechnik ist das Energiepfahlsystem. Mittels 570 Betonpfaehlen und 80 km Rohrschlangen wird das Erdreich unter dem Gebaeude als ueber 100.000 m{sup 3} grosser Waerme- und Kaeltespeicher genutzt. Ueber dieses Energiepfahlsystem wird dieser Druckereibetrieb mit hohen Anforderungen an das Raumklima und viel Maschinenabwaerme sehr umweltschonend im Winter behizt und im Sommer gekuehlt. Das Besondere an diesem System ist diese ganzjaehrige Doppelnutzung zu Heiz- und Kuehlzwecken. Aus diesem Grunde wurde dieses Projekt vom Bundesamt fuer Energiewirtschaft (BEW) als Pilot- und Demonstrationsprojekt anerkannt. Zur Ueberpruefung von dessen Ausbeute und der Wirksamkeit der gesamten Energietechnik wurde vom BEW ein umfangreiches Messprojekt gestartet. Der Innovationswert der PAGO -Energietechnik liegt allerdings nicht allein im Einsatz der alternativen Komponenten. Mindestens so wichtig ist die Konzeption und die Feinabstimmung der gesamten Energietechnik. Der Betrieb lief im ersten Betriebsjahr sehr positiv und von Anfang an ohne groessere Probleme. Das Energiepfahlsystem konnte im wesentlichen die Erwartungen erfuellen. (orig.)

  19. Adaptively loaded SP-offset-QAM OFDM for IM/DD communication systems.

    Science.gov (United States)

    Zhao, Jian; Chan, Chun-Kit

    2017-09-04

    In this paper, we propose adaptively loaded set-partitioned offset quadrature amplitude modulation (SP-offset-QAM) orthogonal frequency division multiplexing (OFDM) for low-cost intensity-modulation direct-detection (IM/DD) communication systems. We compare this scheme with multi-band carrier-less amplitude phase modulation (CAP) and conventional OFDM, and demonstrate >40 Gbit/s transmission over 50-km single-mode fiber. It is shown that the use of SP-QAM formats, together with the adaptive loading algorithm specifically designed to this group of formats, results in significant performance improvement for all these three schemes. SP-offset-QAM OFDM exhibits greatly reduced complexity compared to SP-QAM based multi-band CAP, via parallelized implementation and minimized memory length for spectral shaping. On the other hand, this scheme shows better performance than SP-QAM based conventional OFDM at both back-to-back and after transmission. We also characterize the proposed scheme in terms of enhanced tolerance to fiber intra-channel nonlinearity and the potential to increase the communication security. The studies show that adaptive SP-offset-QAM OFDM is a promising IM/DD solution for medium- and long-reach optical access networks and data center connections.

  20. Monitoring of selected skin- and breath-borne volatile organic compounds emitted from the human body using gas chromatography ion mobility spectrometry (GC-IMS).

    Science.gov (United States)

    Mochalski, Paweł; Wiesenhofer, Helmut; Allers, Maria; Zimmermann, Stefan; Güntner, Andreas T; Pineau, Nicolay J; Lederer, Wolfgang; Agapiou, Agapios; Mayhew, Christopher A; Ruzsanyi, Veronika

    2018-02-15

    Human smuggling and associated cross-border crimes have evolved as a major challenge for the European Union in recent years. Of particular concern is the increasing trend of smuggling migrants hidden inside shipping containers or trucks. Therefore, there is a growing demand for portable security devices for the non-intrusive and rapid monitoring of containers to detect people hiding inside. In this context, chemical analysis of volatiles organic compounds (VOCs) emitted from the human body is proposed as a locating tool. In the present study, an in-house made ion mobility spectrometer coupled with gas chromatography (GC-IMS) was used to monitor the volatile moieties released from the human body under conditions that mimic entrapment. A total of 17 omnipresent volatile compounds were identified and quantified from 35 ion mobility peaks corresponding to human presence. These are 7 aldehydes (acrolein, 2-methylpropanal, 3-methylbutanal, 2-ethacrolein, n-hexanal, n-heptanal, benzaldehyde), 3 ketones (acetone, 2-pentanone, 4-methyl-2-pentanone), 5 esters (ethyl formate, ethyl propionate, vinyl butyrate, butyl acetate, ethyl isovalerate), one alcohol (2-methyl-1-propanol) and one organic acid (acetic acid). The limits of detection (0.05-7.2 ppb) and relative standard deviations (0.6-11%) should be sufficient for detecting these markers of human presence in field conditions. This study shows that GC-IMS can be used as a portable field detector of hidden or entrapped people. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The driver in the 21st century. Demands, applications, aspects of man-machine systems. Lectures; Der Fahrer im 21. Jahrhundert. Anforderungen, Anwendungen, Aspekte fuer Mensch-Maschine-Systeme. Plenarvortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    A high grade of mobility is the basis of our economic development. The innovations in the automotive- and deliver industry lead to different fulfillments of customer expectations on vehicle operation. Also in the railway sector increasing requirements on the operators involve a change of view within design of man-machine interfaces. The transmission of information and transfer of reactions require advanced and balanced concepts for operating and monitoring of modern automobiles. The integral connection of competence in technology, design and ergonomics, sense- and traffic psychology as well as legal problems lead to new challenges and possibilities. (GL) [German] Der Fahrer im 21. Jahrhundert - Anforderungen, Anwendungen, Aspekte fuer Mensch-Maschine-Systeme - unter diesem Motto wird die interessante Fachtagung ''Der Fahrer im 21. Jahrhundert'' fortgefuehrt. Ein hohes Mass an Mobilitaet ist Grundlage unserer wirtschaftlichen Entwicklung. Die Innovationen in der Automobil- und Zuliefererindustrie fuehren zu einer differenzierten Erfuellung der Kundenerwartungen an die Bedienung der Fahrzeuge. Auch im Bereich Bahn bedingen die steigenden Anforderungen an die Fahrzeugfuehrer ein Umdenken bei der Gestaltung der Mensch-Maschine-Schnittstelle. Die Vermittlung von Informationen und die Umsetzung adaequater Reaktionen erfordern neue und ausgewogene Konzepte fuer das Bedienen und Beobachten moderner Fahrzeuge. Die integrale Verbindung von Kompetenz in Technologie, Design und Ergonomie, Wahrnehmungs- und Verkehrspsychologie sowie rechtlichen Fragestellungen fuehren hier zu neuen Herausforderungen und Moeglichkeiten. Die Tagung moechte wieder visionaere Loesungsansaetze aufzeigen und auch das Machbare diskutieren. Nutzen Sie die Gelegenheit, mit namhaften Referenten aus Industrie und Wissenschaft, Fach- und Fuehrungskraeften zu sprechen und auf dieser Veranstaltung neue Bedien- und Informationskonzepte, Teilloesungen fuer die unterschiedlichen Fahraufgaben

  2. Integrated Management System in construction company-effective tool of quality, environment and safety level improving

    OpenAIRE

    Gašparík, Jozef

    2009-01-01

    Contribution Presents the struCture of integrated M anageMent systeM ( iMs) according to international standards ISO 9001:2008, ISO 14001:2004 and STN OHSAS 18001:2009, which consists of 3 management systems focused to quality, environment and safety of building processes. The purpose of paper is to describe basic steps concerning the development of IMS. Paper analises basic processes of IMS like company vision, IMS planning, implementing, monitoring, revive and improving. The paper presents ...

  3. A SURVEY ON INDIAN EXPERIENCE ON INTEGRATED MANAGEMENT STANDARDS (IMS

    Directory of Open Access Journals (Sweden)

    H. Khanna

    2009-09-01

    Full Text Available Adoption of management systems standards is a key issue in manufacturing industry in India. Following the global trend quality and environmental issues are gaining importance. However the number of ISO 14001 certified companies are much less in India as compared to ISO 9001. The integration of ISO 14001 with ISO 9001 may help companies to sustain competitive advantage and overcome disappointments with quality standards and in turn encourage companies to adopt good environmental practices. The aim of this research is to study the implementation of integrated management standards (IMS by the manufacturing organizations in India. The different aspects of integration and benefits of IMS implementation are analyzed. This r esearch is based on empirical study carried out in Indian manufacturing firms, involving the application of a questionnaire. This questionnaire was tested on 50 manufacturing companies in India. The study reveals that focus on stakeholders; top management commitment and training are critical success factors for implementation of IMS. The main benefits of integration are discussed. The small sample size is one of the major limitations of this study. The paper informs the managers in manufacturing organizations and practitioners of management system standards especially in developing countries about IMS and will enable them to adopt IMS in future so that those organizations may not implement multiple and overlapping MSS(Management System Standards.

  4. Advanced Ground Systems Maintenance Anomaly Detection

    Data.gov (United States)

    National Aeronautics and Space Administration — The Inductive Monitoring System (IMS) software utilizes techniques from the fields of model-based reasoning, machine learning, and data mining to build system...

  5. IMS IN SMES - REASONS, ADVANTAGES AND BARRIERS ON IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    Dragan Rajković

    2008-09-01

    Full Text Available Appearance of a number of management systems with various and sometimes divergent demands, demands for revise of optimal strategy on implementation of these standards in small and medium-sized enterprises (SMEs and the attempt on their integration into integrated management system are suggested even more. Firstly question on choice and reasons for implementation of standards is raised. Management and employees expect benefits on the implementation and they pass and minimize the implementation barriers. Basic concept on integrated management system (IMS into SMEs and analyse on reasons, advantages and barriers at IMS implementation are presented in this paper.

  6. Integrating IMS LD and IMS QTIv2 using CopperCore Service Integration

    NARCIS (Netherlands)

    Vogten, Hubert

    2006-01-01

    Vogten, H. (2006). Integrating IMS LD and IMS QTIv2 using CopperCore Service Integration. Presentation at International Workshop in Learning Networks for Lifelong Competence Development. March, 30-31, 2006. Sofia, Bulgaria: TENCompetence Conference. Retrieved June 30th, 2006, from

  7. Experimental demonstration of polar coded IM/DD optical OFDM for short reach system

    Science.gov (United States)

    Fang, Jiafei; Xiao, Shilin; Liu, Ling; Bi, Meihua; Zhang, Lu; Zhang, Yunhao; Hu, Weisheng

    2017-11-01

    In this paper, we propose a novel polar coded intensity modulation direct detection (IM/DD) optical orthogonal frequency division multiplexing (OFDM) system for short reach system. A method of evaluating the channel signal noise ratio (SNR) is proposed for soft-demodulation. The experimental results demonstrate that, compared to the conventional case, ∼9.5 dB net coding gain (NCG) at the bit error rate (BER) of 1E-3 can be achieved after 40-km standard single mode fiber (SSMF) transmission. Based on the experimental result, (512,256) polar code with low complexity and satisfactory BER performance meets the requirement of low latency in short reach system, which is a promising candidate for latency-stringent short reach optical system.

  8. Guidance system monitors regional link network; Leitsystem ueberwacht regionales Verbundleitungsnetz

    Energy Technology Data Exchange (ETDEWEB)

    Gorgas, O. [IDS GmbH, Ettlingen (Germany)

    2002-07-01

    The Harzwasserwerke GmbH, as a regional supplier in Lower Saxony, treat drinking water in dam and ground water works. An approximately 500 km long supply network supplies water to around 70 towns and communities in Northern Germany. This means around one and a half million people are supplied with the life elixir in renowned towns such as Hannover, Wolfsburg (with the Volkswagen AG), Braunschweig, Hildesheim, Goettingen and Bremen. A new network guidance system has been installed to monitor the pipeline system and the feed to water works and feed in and out of high-level reservoirs. (orig.) [German] Die Harzwasserwerke GmbH als Regionalversorger in Niedersachsen bereiten Trinkwasser in Talsperren- und Grundwasserwerken auf. Ueber ein rund 500 km langes Leitungsnetz werden im Norden Deutschlands etwa 70 Staedte und Gemeinden versorgt. Damit werden rund eineinhalb Millionen Menschen mit dem Lebensmittel Nummer Eins, unter anderem in namhaften Staedten wie Hannover, Wolfsburg mit der Volkswagen AG, Braunschweig, Hildesheim, Goettingen und Bremen beliefert. Zur Ueberwachung des Leitungssystems und der Einspeisung an Wasserwerken bzw. Ein- und Ausspeisungen an Hochbehaeltern wurde ein neues Netzleitsystem installiert. (orig.)

  9. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E. [Instituto Tecnologico e Nuclear, Dept. de Proteccao Radiologica e Seguranca Nuclear Estrada Nacional, Sacavem (Portugal)

    2006-07-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  10. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    International Nuclear Information System (INIS)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E.

    2006-01-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  11. India Mission System

    Data.gov (United States)

    US Agency for International Development — A monitoring system to help track IM level targets and roll them up to the element level for the purposes of the PPR. In subsequent phases will build in a GIS...

  12. Delegation und Kooperation im Gesundheitswesen

    OpenAIRE

    Rosenau, Henning

    2010-01-01

    Delegation und Kooperation im Gesundheitswesen. - In: Tıpta işbirliği ve hukuksal sorunlar = Delegation und Kooperation im Gesundheitswesen / ed.: Hakan Hakeri ... - Samsun : Adalet, 2010. - S. 7-18

  13. Innovationsmanagement im Marketing: Anleitung zur Innovations-Sensibilisierung und deren Umsetzung im Rahmen der Neuen Lernkultur

    OpenAIRE

    Mangisch, Christian; Blatter, Martin

    2009-01-01

    Der Kurs “Innovationsmanagement im Marketing“ vermittelt den Teilnehmenden Wissen zum Innovationsmanagement, zum innovativen Team und zu innovativen Marketing Trends. Diese Kurse sind online auf dem folgenden Link www.ritzycampus.ch zu finden. Die Teilnehmer müssen für den Online-Kurs keine speziellen Kenntnisse oder Voraussetzungen mitbringen. Diese Online-Kurse im Fach Marketing sind an ein breites Publikum gerichtet. Sie ermöglichen den Studierenden im Eigenstudium die Grundlagen der Theme...

  14. Wozu und wie kooperative Arbeitsformen im studienbegleitenden Deutschunterricht?

    Directory of Open Access Journals (Sweden)

    Karmelka Barić

    2016-04-01

    Full Text Available Ausgehend von einer Reflexion über die im Beruf und im Leben notwendigen Kompetenzen in der Kommunikation sowie von der Überzeugung, dass es notwendig ist, diese Kompetenzen schon im Studium durch geeignete Arbeitsverfahren und Themen zu entwickeln, werden Kooperation und Autonomie fördernde Arbeitsformen für den studienbegleitenden Deutsch- und Fremdsprachenunterricht (SDU/SFU vorgestellt. Diese Arbeitsformen sind auf andere Sprachen übertragbar und aus dem Lehrwerk Mit Deutsch studieren arbeiten leben A2/B1 (Lévy-Hillerich, Serena, Barić & Cickovska 2010 und der dazu gehörenden Lernplattform entnommen. Das Lehrwerk selbst ist eine Umsetzung der SDU-Rahmencurricula, die im Laufe von über zwanzig Jahren in zehn Ländern im Rahmen eines 1994 am Goethe-Institut Warschau begonnenen Hochschulprojekts und der daraus entstandenen Forschungstätigkeit entstanden sind. Grundlage des Projekts ist ein ganzheitlicher soziopädagogischer Ansatz, der LernerInnen als Menschen betrachtet, die im Präsenz- oder im virtuellen Unterricht in der Sprache und durch die Sprache fach- und sprachübergreifende Kooperationsfähigkeiten entwickeln, die sich später im Leben in der Gesellschaft auswirken. Nach der Vorstellung des Projekts und seiner wissenschaftlichen Hintergründe im ersten Teil des Beitrags werden im zweiten Teil die sich aus dem Ansatz ergebenden Arbeitsformen untersucht: Dabei werden die sich dazu eignenden Themen, die Lernhilfen für StudentInnen, die den LehrerInnen zufallenden Rollen sowie die Ansprüche an Lehrbücher/Unterrichtsmaterialien und Online-/Blended-Learning-Lernszenarien besprochen. Der abschließende Überblick im dritten Teil über die Schwierigkeiten, die beim kooperativen Lernen im SDU/SFU auftreten können, ist gleichzeitig eine offenbleibende Frage danach, wie LehrerInnen aus- und fortgebildet werden sollten, um sich den Anforderungen einer sich dauernd verändernden Lernlandschaft stellen zu können.   The paper

  15. Development of a Fully Automated Guided Wave System for In-Process Cure Monitoring of CFRP Composite Laminates

    Science.gov (United States)

    Hudson, Tyler B.; Hou, Tan-Hung; Grimsley, Brian W.; Yaun, Fuh-Gwo

    2016-01-01

    A guided wave-based in-process cure monitoring technique for carbon fiber reinforced polymer (CFRP) composites was investigated at NASA Langley Research Center. A key cure transition point (vitrification) was identified and the degree of cure was monitored using metrics such as amplitude and time of arrival (TOA) of guided waves. Using an automated system preliminarily developed in this work, high-temperature piezoelectric transducers were utilized to interrogate a twenty-four ply unidirectional composite panel fabricated from Hexcel (Registered Trademark) IM7/8552 prepreg during cure. It was shown that the amplitude of the guided wave increased sharply around vitrification and the TOA curve possessed an inverse relationship with degree of cure. The work is a first step in demonstrating the feasibility of transitioning the technique to perform in-process cure monitoring in an autoclave, defect detection during cure, and ultimately a closed-loop process control to maximize composite part quality and consistency.

  16. Δim-lacunary statistical convergence of order α

    Science.gov (United States)

    Altınok, Hıfsı; Et, Mikail; Işık, Mahmut

    2018-01-01

    The purpose of this work is to introduce the concepts of Δim-lacunary statistical convergence of order α and lacunary strongly (Δim,p )-convergence of order α. We establish some connections between lacunary strongly (Δim,p )-convergence of order α and Δim-lacunary statistical convergence of order α. It is shown that if a sequence is lacunary strongly (Δim,p )-summable of order α then it is Δim-lacunary statistically convergent of order α.

  17. International conference on individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Vanhavere, Filip

    2016-01-01

    This special issue of the journal Radiation Protection Dosimetry is dedicated to the Proceedings of the International Conference on Individual Monitoring of Ionising Radiation (IM2015), which is the fifth of a series of conferences dealing with individual monitoring. This conference series is initiated by EURADOS, the European Radiation Dosimetry Group, and is organised every 5 years. In 2015, the conference was jointly organised by the Belgian Nuclear Research Centre (SCK.CEN), AV Controlatom, and the Vrije Universiteit Brussel. It brought together scientists from regulatory authorities, individual monitoring services (IMS), research bodies, European networks and companies, for the purpose of facilitating the dissemination of knowledge, exchanging experiences and promoting new ideas in the field of individual monitoring. After the conference, 124 papers were submitted for publication in these peer-reviewed proceedings. From these, 103 were finally accepted for publication. The help of the numerous referees and the guest editors is very much appreciated. These proceedings provide a full image of the IM2015 conference. The high-level publications will be useful to improve the state of individual monitoring all over the world and aim to inspire many scientists to continue their work on a better monitoring of radiologically exposed workers

  18. [Kriegsland im Osten Eroberung, Kolonisierung und Militärherrschaft im Ersten Weltkrieg] / Markus Pöhlmann

    Index Scriptorium Estoniae

    Pöhlmann, Markus

    2003-01-01

    Rets.: Vejas Gabriel Liulevicius. Kriegsland im Osten Eroberung, Kolonisierung und Militärherrschaft im Ersten Weltkrieg. Aus dem Amerikanischen von Jürgen Bauer, Edith Nerke und Fee Engemann. Hamburg : 2002

  19. A plan for location calibration of IMS stations and near Kazakhstan

    International Nuclear Information System (INIS)

    Richards, P.G.; Kim, W.-Yo.; Khalturin, V.I.

    2001-01-01

    For purposes of monitoring compliance with the Comprehensive Nuclear Test-Ban Treaty, it is desirable to be able to locate seismic events routinely to within an uncertainty not greater than 1000 square km. From more than five years of experience with publication of the Reviewed Event Bulletin (REB) by the Prototype International Data Centre (PIDC), resulting in estimated locations for more than 100,000 seismic events, it is apparent that improved location accuracy is needed in order to reduce uncertainties below 1000 square km. In this paper, we outline a three-year program of applied research which commenced in March 2000 and which has the goal of achieving improved REB locations based upon data to be contributed to the International Data Centre from 30 IMS stations in Eastern Asia. Our first efforts will focus on the four IMS seismographic stations in Kazakhstan (AKT, BRV, KUR, MAK), together with IMS stations ZAL in Russia and AAK in Kyrgyzstan. Following the recommendations of two 'IMS Location Calibration Workshops' held in Oslo, Norway, in 1999 and 2000, our approach is to generate station-specific travel times for each observable seismic phase, as a function of distance and azimuth (and depth, where possible). Such travel times are obtained on the basis of (i) early studies based mainly on earthquake data (e.g. Nersesov and Rautian, 1964), (ii) Deep Seismic Sounding, and (iii) recent studies of nuclear and chemical explosions. We are also using (iv) an empirical approach in which phases are picked at IMS stations, for so-called Ground Truth events whose location is known quite accurately on the basis of additional data, obtained for example from local and regional networks. (author)

  20. CopperCore Service Integration, Integrating IMS Learning Design and IMS Question and Test Interoperability

    NARCIS (Netherlands)

    Vogten, Hubert; Martens, Harrie; Nadolski, Rob; Tattersall, Colin; Van Rosmalen, Peter; Koper, Rob

    2006-01-01

    Vogten, H., Martens, H., Nadolski, R., Tattersall, C., Rosmalen, van, P., Koper, R., (2006). CopperCore Service Integration, Integrating IMS Learning Design and IMS Question and Test Interoperability. Proceedings of the 6th IEEE International Conference on Advanced Learning Technologies (pp.

  1. Volatility study of [C1C1im][NTf2] and [C2C3im][NTf2] ionic liquids

    International Nuclear Information System (INIS)

    Rocha, Marisa A.A.; Ribeiro, Filipe M.S.; Schröder, Bernd; Coutinho, João A.P.; Santos, Luís M.N.B.F.

    2014-01-01

    Highlights: • Vapor pressures of [C 1 C 1 im][NTf 2 ] and [C 2 C 3 im][NTf 2 ] ionic liquids are reported. • [C 1 C 1 im][NTf 2 ] presents higher enthalpy and entropy of vaporization than expected. • The high volatility of [C 2 C 3 im][NTf 2 ] is a result from its asymmetric character. -- Abstract: Vapor pressures of 1,3-dimethylimidazolium bis(trifluoromethylsulfonyl)imide, ([C 1 C 1 im][NTf 2 ]) and 1-ethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide, ([C 2 C 3 im][NTf 2 ]) ionic liquids were measured as a function of temperature using a Knudsen effusion apparatus combined with a quartz crystal microbalance. Enthalpies and entropies of vaporization were derived from the fitting of vapor pressure and temperature results to the Clarke and Glew equation. [C 1 C 1 im][NTf 2 ] presents a higher enthalpy and entropy of vaporization than the neighboring members of the series. The enthalpy of vaporization of [C 2 C 3 im][NTf 2 ] lies in between the asymmetric and symmetric ionic liquid series, reflecting a decrease in the electrostatic interactions due to a decrease of the charge accessibility between the ionic pairs when the methyl group is replaced by an ethyl group. The obtained higher volatility of [C 2 C 3 im][NTf 2 ] arises from its asymmetric character, leading to an higher entropic contribution that compensates the enthalpic penalty. The border conditions ([C 1 C 1 im][NTf 2 ], [C 2 C 1 im][NTf 2 ] and [C 2 C 2 im][NTf 2 ]), topology ([C 2 C 3 im][NTf 2 ]) and symmetry/asymmetry of the ILs effect were evaluated and rationalized based on a comparative analysis of the thermodynamic properties, enthalpies and entropies of vaporization

  2. Application of Hadamard transform in IMS

    International Nuclear Information System (INIS)

    Sha Miaomiao; Liu Weihao; Chen Yong; Jiang Dazhen

    2008-01-01

    Hadamard transform can improve the SNR by increasing the ion duty cycle in IMS. In this paper, the ion spectral signals were processed by Hadamard transform based on the IMS detector hardware platform. The results showed that Hadamard transform can greatly improve the SNR of the IMS detector in contrast with traditional method. (authors)

  3. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  4. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  5. Environmental trace analysis by means of supersensitive GC-IMS

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1997-01-01

    The effective control of pollutants in ambient air requires their fast in situ identification and concentration determination of chemical compounds in the range of micrograms per m 3 . There are attempts to use conventional analytical techniques as portable GC and GC-MS. These systems are relatively expensive. A new supersensitive ion Mobility Sensor (IMS) was developed and checked by IUT Ltd, which meets the new demands. The use of tritium sources is an advantage in comparison with other IMS being equipped by nickel-63, the application of which is rather critical in respect of the radiation protection. On the other hand an integrated separation column allows to reduce interferences by matrix effects. The technical parameters of the IUT GC- IMS and some of its most important applications are briefly presented

  6. An Analysis of the Effect of the Implementation of an Integrated Management System (IMS on Work Ergonomics in an O&M Power Plant Company

    Directory of Open Access Journals (Sweden)

    Dewi Permata Ifadiana

    2016-05-01

    Full Text Available Ergonomics has developed significantly for the prevention of related accidents. Its implementation, however, depends on the existing management system within a company. The integrated management system (IMS is frequently implemented in industry, which is an integration of ISO 9001, ISO 14001, and OHSAS 18001. The objectives of this research were to analyze the effects of IMS implementation on work ergonomics and to find the influencing factors. The methods used were the 4x4 method for investigating accidents; interviews; and a questionnaire for workers and managers at an electricity company. The subjects were divided into three levels, namely: top management, middle management, and workers. Logistic regression was used to analyze and estimate the effects of one or more management variables on ergonomics related accidents. The results showed that the implementation of IMS has supported work ergonomics very well based on the average scores, which ranged from 2.99 to 3.38. The logistic regression showed that the most influential IMS on work ergonomics was the Do (D of Deming’s PDCA cycle, whereas the most influential parameter for ergonomics accident prevention was Policy (P and Do (D at the top management level.

  7. Zur mediopassiven 2. Und 3. Person dualis im indogermanischen

    Directory of Open Access Journals (Sweden)

    Bojan Čop

    1972-12-01

    Full Text Available Bekanntlich gibt es in einigen seltenen idg. Sprachen (im Arischen, Griechischen, Tocharischen auch Personal - suffixe für die 2. u n d 3. P. Du. des Mediopassivs. Von diesen sind die griechischen Ausgänge – 2. und 3. Du primär, 2. Du. sekundär, Du. sekundär sicher junge Neubildungen, s. z. B. Brugmann, Grdr.2 II 3 II, 657, § 602; Schwyzer, Gr. Gr. I 670, 672. Ein voll ausgebildetes System solcher Endungen besitzt das Arische; im Tocharischen kommt nur eine einzige Form mit solcher Endung vor, die die 2. P. Du. Med. lmperativi darstellt. Unter solchen Umständen scheint es schwierig, aus diesem Material wahrscheinliche Schlüsse für da_s Urindogermanische zu machen. Und doch ist gerade die tocharische Form, die uns eine ausserordentlich grosse Hilfe leistet, wenn man sie richtig zu beurteilen vermag. Die tocharische Endung, verbunden mit den arischen, wird unter Einschluss der allgemeinen Tendenzen und Regelungen im System der indogermanischen Personalsuffixe ohne Schwierigkeit die urindogermanische Urform erscheinen lassen.

  8. An IMS testbed for SIP applications

    DEFF Research Database (Denmark)

    Caba, Cosmin Marius; Soler, José

    2013-01-01

    The paper presents the design and implementation of an emulation platform for the IP Multimedia Subsystem. The SIP Servlet API v1.1 has been used to implement the final system. The purpose of the emulation is to offer to IMS service developers an environment where they can integrate development...

  9. Using Autonomous Underwater Vehicles as Sensor Platforms for Ice-Monitoring

    Directory of Open Access Journals (Sweden)

    Petter Norgren

    2014-10-01

    Full Text Available Due to the receding sea-ice extent in the Arctic, and the potentially large undiscovered petroleum resources present north of the Arctic circle, offshore activities in ice-infested waters are increasing. Due to the presence of drifting sea-ice and icebergs, ice management (IM becomes an important part of the offshore operation, and an important part of an IM system is the ability to reliably monitor the ice conditions. An autonomous underwater vehicle (AUV has a unique capability of high underwater spatial and temporal coverage, making it suitable for monitoring applications. Since the first Arctic AUV deployment in 1972, AUV technology has matured and has been used in complex under-ice operations. This paper motivates the use of AUVs as an ice-monitoring sensor platform. It discusses relevant sensor capabilities and challenges related to communication and navigation. This paper also presents experiences from a field campaign that took place in Ny-Aalesund at Svalbard in January 2014, where a REMUS 100 AUV was used for sea-floor mapping and collection of oceanographic parameters. Based on this, we discuss the experiences related to using AUVs for ice-monitoring. We conclude that AUVs are highly applicable for ice-monitoring, but further research is needed.

  10. Instrument response measurements of ion mobility spectrometers in situ: maintaining optimal system performance of fielded systems

    Science.gov (United States)

    Wallis, Eric; Griffin, Todd M.; Popkie, Norm, Jr.; Eagan, Michael A.; McAtee, Robert F.; Vrazel, Danet; McKinly, Jim

    2005-05-01

    Ion Mobility Spectroscopy (IMS) is the most widespread detection technique in use by the military for the detection of chemical warfare agents, explosives, and other threat agents. Moreover, its role in homeland security and force protection has expanded due, in part, to its good sensitivity, low power, lightweight, and reasonable cost. With the increased use of IMS systems as continuous monitors, it becomes necessary to develop tools and methodologies to ensure optimal performance over a wide range of conditions and extended periods of time. Namely, instrument calibration is needed to ensure proper sensitivity and to correct for matrix or environmental effects. We have developed methodologies to deal with the semi-quantitative nature of IMS and allow us to generate response curves that allow a gauge of instrument performance and maintenance requirements. This instrumentation communicates to the IMS systems via a software interface that was developed in-house. The software measures system response, logs information to a database, and generates the response curves. This paper will discuss the instrumentation, software, data collected, and initial results from fielded systems.

  11. Imágenes e identidades

    OpenAIRE

    Guerrini, Sebastión

    2013-01-01

    Las identidades se estructuran en un proceso de identificación continua con imágenes. Esto afecta no solo a las identidades de las personas, sino también a las de las instituciones, organizaciones y empresas. En este sentido, el rol de ser del Diseño en Comunicación Visual es intentar afectar a las identidades de los espectadores de sus imágenes. Por esta razón, primero es importante definir qué son las imágenes. Facultad de Bellas Artes

  12. λ (Δim) -statistical convergence of order α

    Science.gov (United States)

    Colak, Rifat; Et, Mikail; Altin, Yavuz

    2017-09-01

    In this study, using the generalized difference operator Δim and a sequence λ = (λn) which is a non-decreasing sequence of positive numbers tending to ∞ such that λn+1 ≤ λn+1, λ1 = 1, we introduce the concepts of λ (Δim) -statistical convergence of order α (α ∈ (0, 1]) and strong λ (Δim) -Cesàro summablility of order α (α > 0). We establish some connections between λ (Δim) -statistical convergence of order α and strong λ (Δim) -Cesàro summablility of order α. It is shown that if a sequence is strongly λ (Δim) -Cesàro summable of order α, then it is λ (Δim) -statistically convergent of order β in case 0 < α ≤ β ≤ 1.

  13. Intelligent monitoring system for real-time geologic CO2 storage, optimization and reservoir managemen

    Science.gov (United States)

    Dou, S.; Commer, M.; Ajo Franklin, J. B.; Freifeld, B. M.; Robertson, M.; Wood, T.; McDonald, S.

    2017-12-01

    Archer Daniels Midland Company's (ADM) world-scale agricultural processing and biofuels production complex located in Decatur, Illinois, is host to two industrial-scale carbon capture and storage projects. The first operation within the Illinois Basin-Decatur Project (IBDP) is a large-scale pilot that injected 1,000,000 metric tons of CO2 over a three year period (2011-2014) in order to validate the Illinois Basin's capacity to permanently store CO2. Injection for the second operation, the Illinois Industrial Carbon Capture and Storage Project (ICCS), started in April 2017, with the purpose of demonstrating the integration of carbon capture and storage (CCS) technology at an ethanol plant. The capacity to store over 1,000,000 metric tons of CO2 per year is anticipated. The latter project is accompanied by the development of an intelligent monitoring system (IMS) that will, among other tasks, perform hydrogeophysical joint analysis of pressure, temperature and seismic reflection data. Using a preliminary radial model assumption, we carry out synthetic joint inversion studies of these data combinations. We validate the history-matching process to be applied to field data once CO2-breakthrough at observation wells occurs. This process will aid the estimation of permeability and porosity for a reservoir model that best matches monitoring observations. The reservoir model will further be used for forecasting studies in order to evaluate different leakage scenarios and develop appropriate early-warning mechanisms. Both the inversion and forecasting studies aim at building an IMS that will use the seismic and pressure-temperature data feeds for providing continuous model calibration and reservoir status updates.

  14. Miniature GC-Minicell Ion Mobility Spectrometer (IMS) for In Situ Measurements in Astrobiology Planetary Missions

    Science.gov (United States)

    Kojiro, Daniel R.; Stimac, Robert M.; Kaye, William J.; Holland, Paul M.; Takeuchi, Norishige

    2006-01-01

    Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or ionger mission life for stationary landers/laboratories. The miniCometary Ice and Dust Experiment (miniCIDEX), which combined Gas Chromatography (GC) with helium Ion Mobility Spectrometry (IMS), was capable of providing the wide range of analytical information required for Astrobiology missions. The IMS used here was based on the PCP model 111 IMS. A similar system, the Titan Ice and Dust Experiment (TIDE), was proposed as part of the Titan Orbiter Aerorover Mission (TOAM). Newer GC systems employing Micro Electro- Mechanical System (MEMS) based technology have greatly reduced both the size and resource requirements for space GCs. These smaller GCs, as well as the continuing miniaturization of Astrobiology analytical instruments in general, has highlighted the need for smaller, dry helium IMS systems. We describe here the development of a miniature, MEMS GC-IMS system (MEMS GC developed by Thorleaf Research Inc.), employing the MiniCell Ion Mobility Spectrometer (IMS), from Ion Applications Inc., developed through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA s Small Business Innovative Research (SBIR) Program.

  15. Hinderniserkennung und -verfolgung mit einer PMD-kamera im automobil

    Science.gov (United States)

    Schamm, Thomas; Vacek, Stefan; Natroshvilli, Koba; Marius Zöllner, J.; Dillmann, Rüdiger

    Die Detektion von Hindernissen vor dem Automobil ist eine Hauptanforderung an moderne Fahrerassistenzsysteme (FAS). In dieser Arbeit wird ein System vorgestellt, das mit Hilfe einer PMDKamera (Photomischdetektor) Hindernisse auf der Fahrspur erkennt und deren relevante Parameter bestimmt. Durch die PMD-Kamera werden zunächst 3D-Tiefenbilder der Fahrzeugumwelt generiert. Nach einem initialen Filterprozess werden im Tiefenbild mit Hilfe eines Bereichswachstumsverfahrens Hindernisse gesucht. Zur Stabilisierung des Verfahrens und zur Parameterberechnung wird ein Kaiman Filter eingesetzt. Das Ergebnis ist eine Liste aller Hindernisse im Fahrbereich des Automobils.

  16. Advanced Interval Management (IM) Concepts of Operations

    Science.gov (United States)

    Barmore, Bryan E.; Ahmad, Nash'at N.; Underwood, Matthew C.

    2014-01-01

    This document provides a high-level description of several advanced IM operations that NASA is considering for future research and development. It covers two versions of IM-CSPO and IM with Wake Mitigation. These are preliminary descriptions to support an initial benefits analysis

  17. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  18. Integrating IMS Learning Design and IMS Question and Test Interoperability using CopperCore Service Integration

    NARCIS (Netherlands)

    Vogten, Hubert; Martens, Harrie; Nadolski, Rob; Tattersall, Colin; Van Rosmalen, Peter; Koper, Rob

    2006-01-01

    Please, cite this publication as: Vogten, H., Martens, H., Nadolski, R., Tattersall, C., van Rosmalen, P., & Koper, R. (2006). Integrating IMS Learning Design and IMS Question and Test Interoperability using CopperCore Service Integration. Proceedings of International Workshop in Learning Networks

  19. Environmental trace analysis by means of supersensitive GC-IMS

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, J.W. [IUTLimited, Berlin, (Germany)

    1997-10-01

    The effective control of pollutants in ambient air requires their fast in situ identification and concentration determination of chemical compounds in the range of micrograms per m{sup 3}. There are attempts to use conventional analytical techniques as portable GC and GC-MS. These systems are relatively expensive. A new supersensitive ion Mobility Sensor (IMS) was developed and checked by IUT Ltd, which meets the new demands. The use of tritium sources is an advantage in comparison with other IMS being equipped by nickel-63, the application of which is rather critical in respect of the radiation protection. On the other hand an integrated separation column allows to reduce interferences by matrix effects. The technical parameters of the IUT GC- IMS and some of its most important applications are briefly presented 6 refs., 1 tab., 5 figs.

  20. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  1. Medienpädagogische Aufgabenfelder hinsichtlich der Visualität im digitalen Zeitalter. Desiderate im Umgang mit visuellen Medienkulturen

    Directory of Open Access Journals (Sweden)

    Petra Missomelius

    2017-04-01

    Full Text Available Die bildungskulturell leitende Funktion des Buches diffundiert im digitalen Zeitalter mobiler und transversaler Systeme von Netzwerkmedien. Zudem sind soziokulturelle Lebenswelten wie Bildungsinstitutionen, Familie und Peers durch Heterogenität gekennzeichnet. Indem auch diese Teil des Geflechts medienkultureller Architekturen werden, geraten ehemals gültige Unterscheidungsparameter wie explizites und implizites, formelles und informelles Wissen ins Wanken. Grenzziehungen und konkurrierende Auffassungen gegenüber diesen, vormals als der Bildung entgegengesetzt wahrgenommenen, Bereichen erweisen sich nunmehr als problematisch. So spielt Visualität im Kontext multimodal zusammengesetzter Bildungsmaterialien eine zunehmende Rolle und wird als Möglichkeit des Umgangs mit Komplexität eingesetzt. Wenngleich somit die Zurückhaltung gegenüber (Bewegt-Bildmedien in der pädagogischen Praxis schwindet, so haben sich mit der Digitalisierung medienkulturell bedeutsame Felder eröffnet, welche erziehungswissenschaftlicher Beachtung bedürfen. Eine sich der Komplexität digitaler Medienkulturen stellende Medienpädagogik bringt mit sich, dass auch Funktion und Gebrauch visueller Medien im Kontext von Bildungsprozessen reflektiert stattfinden. Medienpädagogisch informiertes Agieren in visuellen Medienkulturen ist darüber hinaus heute gerade deshalb essentiell, da es sich bei digital generierter Visualität um eine neue Qualität im Unterschied zu traditionellen Bildmedien handelt, welche der Logik der Repräsentation entsprachen. Der Beitrag thematisiert Desiderate, die sich hinsichtlich des Visuellen datenbasierter Medien für die Medienpädagogik ergeben, und geht dabei auf kommunikative Bildlichkeit, auf paradigmatische mediale Formen und auf datengestützte Wissensgenerierung ein.

  2. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  3. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  4. Calibrating a novel multi-sensor physical activity measurement system

    International Nuclear Information System (INIS)

    John, D; Sasaki, J E; Howe, C A; Freedson, P S; Liu, S; Gao, R X; Staudenmayer, J

    2011-01-01

    Advancing the field of physical activity (PA) monitoring requires the development of innovative multi-sensor measurement systems that are feasible in the free-living environment. The use of novel analytical techniques to combine and process these multiple sensor signals is equally important. This paper describes a novel multi-sensor 'integrated PA measurement system' (IMS), the lab-based methodology used to calibrate the IMS, techniques used to predict multiple variables from the sensor signals, and proposes design changes to improve the feasibility of deploying the IMS in the free-living environment. The IMS consists of hip and wrist acceleration sensors, two piezoelectric respiration sensors on the torso, and an ultraviolet radiation sensor to obtain contextual information (indoors versus outdoors) of PA. During lab-based calibration of the IMS, data were collected on participants performing a PA routine consisting of seven different ambulatory and free-living activities while wearing a portable metabolic unit (criterion measure) and the IMS. Data analyses on the first 50 adult participants are presented. These analyses were used to determine if the IMS can be used to predict the variables of interest. Finally, physical modifications for the IMS that could enhance the feasibility of free-living use are proposed and refinement of the prediction techniques is discussed

  5. Building M7-0505 Treatment Tank (SWMU 039) Annual Performance Monitoring Report

    Science.gov (United States)

    2015-01-01

    This Annual Performance Monitoring Report presents a summary of Interim Measure (IM) activities and an evaluation of data collected during the third year (June 2014 to September 2015) of operation, maintenance, and monitoring (OM&M) conducted at the Building M7-505 (M505) Treatment Tank area, Kennedy Space Center (KSC), Florida ("the Site"). Under KSC's Resource Conservation and Recovery Act Corrective Action Program, the M505 Treatment Tank area was designated Solid Waste Management Unit 039. Arcadis U.S., Inc. (Arcadis) began IM activities on January 10, 2012, after completion of construction of an in situ air sparge (IAS) system to remediate volatile organic compounds (VOCs) in groundwater at concentrations exceeding applicable Florida Department of Environmental Protection (FDEP) Chapter 62-777, Florida Administrative Code, Natural Attenuation Default Concentrations (NADCs). This report presents a summary of the third year of OM&M activities conducted between June 2014 and September 2015.

  6. Synthesis and DNA binding properties of 1-(3-aminopropyl)-imidazole-containing triamide f-Im*PyIm: a novel diamino polyamide designed to target 5'-ACGCGT-3'.

    Science.gov (United States)

    Satam, Vijay; Babu, Balaji; Porte, Alexander; Savagian, Mia; Lee, Megan; Smeltzer, Thomas; Liu, Yang; Ramos, Joseph; Wilson, W David; Lin, Shicai; Kiakos, Kostantinos; Hartley, John A; Lee, Moses

    2012-09-15

    A novel diamino/dicationic polyamide f-Im(*)PyIm (5) that contains an orthogonally positioned aminopropyl chain on an imidazole (Im(*)) moiety was designed to target 5'-ACGCGT-3'. The DNA binding properties of the diamino polyamide 5, determined by CD, ΔT(M), DNase I footprinting, SPR, and ITC studies, were compared with those of its monoamino/monocationic counterpart f-ImPyIm (1) and its diamino/dicationic isomer f-ImPy(*)Im (2), which has the aminopropyl group attached to the central pyrrole unit (Py(*)). The results gave evidence for the minor groove binding and selectivity of polyamide 5 for the cognate sequence 5'-ACGCGT-3', and with strong affinity (K(eq)=2.3×10(7) M(-1)). However, the binding affinities varied according to the order: f-ImPy(*)Im (2)>f-ImPyIm (1)≥f-Im(*)PyIm (5) confirming that the second amino group can improve affinity, but its position within the polyamide can affect affinity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. An Integrated Management System (IMS) for JM-1 SLOWPOKE-2 research reactor in Jamaica: experiences in documentation

    International Nuclear Information System (INIS)

    Warner, T.

    2014-01-01

    Since the first criticality in March 1984, the Jamaica SLOWPOKE-2 research reactor at the University of the West Indies, Mona located in the department of the International Centre for Environmental and Nuclear Sciences (ICENS) has operated for approximately 52% of the lifetime of the existing core configuration. The 20kW pool type research reactor has been primarily used for neutron activation analysis in environmental, agricultural, geochemical, health-related studies and mineral exploration in Jamaica. The involvement of the JM-1 reactor for research and teaching activities has segued into commercial applications which, coupled with the current core conversion programme from HEU to LEU, has demanded the implementation of management systems to satisfy regulatory requirements and assure compliance with internationally defined quality standards. At ICENS, documentation related to the Quality Management System aspect of an Integrated Management System (IMS) is well underway. The quality system will incorporate operational and nuclear safety, training, maintenance, design, utilization, occupational health and safety, quality service, and environmental management for its Nuclear Analytical Laboratory, NAL. The IMS is being designed to meet the requirements of the IAEA GS-R-3 with additional controls from international standards including: ISO/IEC 17025:2005, ISO 9001:2008, ISO 14001:2004 and OHSAS 18001:2007. This paper reports on the experiences of the documentation process in a low power reactor facility characterized by limited human resource, where innovative mechanisms of system automation and modeling are included to increase productivity and efficiency. (author)

  8. An Integrated Management System (IMS) for JM-1 SLOWPOKE-2 research reactor in Jamaica: experiences in documentation

    Energy Technology Data Exchange (ETDEWEB)

    Warner, T., E-mail: traceyann.warner02@uwimona.edu.jm [Univ. of West Indies, Mona (Jamaica)

    2014-07-01

    Since the first criticality in March 1984, the Jamaica SLOWPOKE-2 research reactor at the University of the West Indies, Mona located in the department of the International Centre for Environmental and Nuclear Sciences (ICENS) has operated for approximately 52% of the lifetime of the existing core configuration. The 20kW pool type research reactor has been primarily used for neutron activation analysis in environmental, agricultural, geochemical, health-related studies and mineral exploration in Jamaica. The involvement of the JM-1 reactor for research and teaching activities has segued into commercial applications which, coupled with the current core conversion programme from HEU to LEU, has demanded the implementation of management systems to satisfy regulatory requirements and assure compliance with internationally defined quality standards. At ICENS, documentation related to the Quality Management System aspect of an Integrated Management System (IMS) is well underway. The quality system will incorporate operational and nuclear safety, training, maintenance, design, utilization, occupational health and safety, quality service, and environmental management for its Nuclear Analytical Laboratory, NAL. The IMS is being designed to meet the requirements of the IAEA GS-R-3 with additional controls from international standards including: ISO/IEC 17025:2005, ISO 9001:2008, ISO 14001:2004 and OHSAS 18001:2007. This paper reports on the experiences of the documentation process in a low power reactor facility characterized by limited human resource, where innovative mechanisms of system automation and modeling are included to increase productivity and efficiency. (author)

  9. Distance tracking scheme for seamless handover in IMS-based ...

    African Journals Online (AJOL)

    This paper proposes a fast and seamless handover scheme for systems based on IP Multimedia Subsystem (IMS) architectural framework with Universal Mobile Telecommunications System (UMTS) access network. In the scheme the location, direction and movement pattern of a Mobile Node (MN) in a network cell are ...

  10. Challenges in Regional CTBT Monitoring: The Experience So Far From Vienna

    Science.gov (United States)

    Bratt, S. R.

    2001-05-01

    The verification system being established to monitor the CTBT will include an International Monitoring System (IMS) network of 321 seismic, hydroacoustic, infrasound and radionuclide stations, transmitting digital data to the International Data Centre (IDC) in Vienna, Austria over a Global Communications Infrastructure (GCI). The IDC started in February 2000 to disseminate a wide range of products based on automatic processing and interactive analysis of data from about 90 stations from the four IMS technologies. The number of events in the seismo-acoustic Reviewed Event Bulletins (REB) was 18,218 for the year 2000, with the daily number ranging from 30 to 360. Over 300 users from almost 50 Member States are now receiving an average of 18,000 data and product deliveries per month from the IDC. As the IMS network expands (40 - 60 new stations are scheduled start transmitting data this year) and as GCI communications links bring increasing volumes of new data into Vienna (70 new GCI sites are currently in preparation), the monitoring capability of the IMS and IDC has the potential to improve significantly. To realize this potential, the IDC must continue to improve its capacity to exploit regional seismic data from events defined by few stations with large azimuthal gaps. During 2000, 25% of the events in the REB were defined by five or fewer stations. 48% were defined by at least one regional phase, and 24% were defined by at least three. 34% had gaps in azimuthal coverage of more than 180 degrees. The fraction of regional, sparsely detected events will only increase as new, sensitive stations come on-line, and the detection threshold drops. This will be offset, to some extent, because stations within the denser network that detect near-threshold events will be at closer distances, on average. Thus to address the challenges of regional monitoring, the IDC must integrate "tuned" station and network processing parameters for new stations; enhanced and/or new methods

  11. MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

    International Nuclear Information System (INIS)

    Laub, S; Dunn, M; Galbreath, G; Gans, S; Pankuch, M

    2015-01-01

    Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient

  12. MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

    Energy Technology Data Exchange (ETDEWEB)

    Laub, S [CDH Proton Center, Warrenville, IL (United States); Dunn, M [Proton Collaborative Group, Warrenville, Illinois (United States); Galbreath, G [ProCure Treatment Centers Inc., New York, NY (United States); Gans, S [Northwestern Memorial Chicago Proton Center, Warrenville, Illinois (United States); Pankuch, M [Northwestern Medicine Chicago Proton Center, Warrenville, IL (United States)

    2015-06-15

    Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient

  13. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  14. A New IMS Based Inter-working Solution

    Science.gov (United States)

    Zhu, Zhongwen; Brunner, Richard

    With the evolution of third generation network, more and more multimedia services are developed and deployed. Any new service to be deployed in IMS network is required to inter-work with existing Internet communities or legacy terminal users in order to appreciate the end users, who are the main drivers for the service to succeed. The challenge for Inter-working between IMS (IP Multimedia Subsystem) and non-IMS network is “how to handle recipient’s address”. This is because each network has its own routable address schema. For instance, the address for Google Talk user is xmpp:xyz@google.com, which is un-routable in IMS network. Hereafter a new Inter-working (IW) solution between IMS and non-IMS network is proposed for multimedia services that include Instant Messaging, Chat, and File transfer, etc. It is an end-to-end solution built on IMS infrastructure. The Public Service Identity (PSI) defined in 3GPP standard (3rd Generation Partnership Project) is used to allow terminal clients to allocate this IW service. When sending the SIP (Session Initial Protocol) request out for multimedia services, the terminal includes the recipient’s address in the payload instead of the “Request-URI” header. In the network, the proposed solution provides the mapping rules between different networks in MM-IW (Multimedia IW). The detailed technical description and the corresponding use cases are present. The comparison with other alternatives is made. The benefits of the proposed solution are highlighted.

  15. Lessons Learned In Aerosol Monitoring With The RASA

    International Nuclear Information System (INIS)

    Forrester, Joel B.; Bowyer, Ted W.; Carty, Fitz; Comes, Laura; Eslinger, Paul W.; Greenwood, Lawrence R.; Haas, Derek A.; Hayes, James C.; Kirkham, Randy R.; Lepel, Elwood A.; Litke, Kevin E.; Miley, Harry S.; Morris, Scott J.; Schrom, Brian T.; Van Davelaar, Peter; Woods, Vincent T.

    2011-01-01

    The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

  16. Replacement of the feedwater pipe system in reactor building outside containment at the nuclear power plant Philippsburg; Austausch der Speisewasserleitung im Reaktorgebaeude ausserhalb SHB im Kernkraftwerk Philippsburg I

    Energy Technology Data Exchange (ETDEWEB)

    Kessler, A. [Energie-Versorgung Schwaben AG, Stuttgart (Germany); Labes, M. [Siemens AG Unternehmensbereich KWU, Offenbach am Main (Germany); Schwenk, B. [Kernkraftwerk Philippsburg GmbH (Germany)

    1998-11-01

    After full replacement of the feedwater pipe system during the inspection period in 1997, combined with a modern materials, manufacturing and analysis concept, the entire pipe system of the water/steam cycle in the reactor building of KKP 1 now consists of high-toughness materials. The safety level of the entire plant has been increased by leaving aside postulation of F2 breaks in the reactor building and providing for protection against 0.1 leaks. Based on fluid-dynamic calculations for the cases of pump failure and pipe break, as well as pipe system calculations in 5 extensive calculation cycles, about 130 documents were filed for inspection and approval (excluding preliminary test documents on restraints). Points of main interest for safety analysis in this context were the optimised closing performance of the 3rd check valves and the integrity of the nozzle region at the RPV. (oirg./CB) [Deutsch] Durch den Restaustausch der Speisewasserleitungen in der Revision 1997, verbunden mit einem modernen Werkstoff-, Fertigungs- und Nachweiskonzept, sind im Reaktorgebaeude von KKP 1 in den Hauptleitungen des Wasser-Dampf-Kreislaufes nur noch hochzaehe Werkstoffe eingesetzt. Durch den Verzicht auf das Postulat von 2F-Bruechen im Reaktorgebaeude und durch die Auslegung gegen 0,1F-Lecks wird das Sicherheitsniveau der Anlage insgesamt gesteigert. Ausgehend von fluiddynamischen Berechnungen fuer Pumpenausfall und Rohrbruch sowie Rohrsystem-Berechnungen in 5 umfangreichen Berechnungskreisen wurden fuer die Genehmigung und Begutachtung ca. 130 Unterlagen (ohne Halterungs-Vorpruefunterlagen) eingereicht und vom Gutachter geprueft. Schwerpunkte der Nachweisfuehrung waren die Optimierung des Schliessverhaltens der 3. Rueckschlagarmaturen sowie der Integritaetsnachweis des RDB-Anschlusses. (orig./MM)

  17. ImBuild: Impact of building energy efficiency programs

    Energy Technology Data Exchange (ETDEWEB)

    Scott, M.J.; Hostick, D.J.; Belzer, D.B.

    1998-04-01

    As part of measuring the impact of government programs on improving the energy efficiency of the Nation`s building stock, the Department of Energy Office of Building Technology, State and Community Programs (BTS) is interested in assessing the economic impacts of its portfolio of programs, specifically the potential impact on national employment and income. The special-purpose version of the IMPLAN model used in this study is called ImBuild. In comparison with simple economic multiplier approaches, such as Department of Commerce RIMS 2 system, ImBuild allows for more complete and automated analysis of the economic impacts of energy efficiency investments in buildings. ImBuild is also easier to use than existing macroeconomic simulation models. The authors conducted an analysis of three sample BTS energy programs: the residential generator-absorber heat exchange gas heat pump (GAX heat pump), the low power sulfur lamp (LPSL) in residential and commercial applications, and the Building America program. The GAX heat pump would address the market for the high-efficiency residential combined heating and cooling systems. The LPSL would replace some highly efficient fluorescent commercial lighting. Building America seeks to improve the energy efficiency of new factory-built, modular, manufactured, and small-volume, site-built homes through use of systems engineering concepts and early incorporation of new products and processes, and by increasing the demand for more energy-efficient homes. The authors analyze a scenario for market penetration of each of these technologies devised for BTS programs reported in the BTS GPRA Metrics Estimates, FY99 Budget Request, December 19, 1997. 46 figs., 4 tabs.

  18. Argumentellipse in der "weichen" Nachricht im Deutschen und im Slowenischen

    Directory of Open Access Journals (Sweden)

    Uršula Krevs

    1998-12-01

    Full Text Available Argumentellipsen werden in der sprachlichen Kommunikation ohne weiteres akzeptiert, obwohl sie allenfalls in gewissem Sinne wegen ihrer Elliptizität abweichend wirken. Im folgenden interessiert uns, wie die Argumentellipse als syntaktische Entität in den Text eingebettet wird und welche Funktionen sie ausübt. Unsere Aufmerksamkeit gilt bier der Textsorte "weiche" Nachricht, die als Abweichung des Grundmusters gilt. Um im Sprachenpaar Deutsch-Slowenisch die in dieser Textsorte realisierten Argumentellipsen vergleichen zu können, wurde die Homogenität in der Thematik angestrebt und die Texte aus dem gleichen Kommunikationsbereich gewählt. So wurden die Korpora zwei Zeitschriften, die sich mit der gleichen Sportart beschäftigen, entnommen: der deutschen Zeitschrift "Rotpunkt" und der slowenischen Zeitschrift  "Grif '.

  19. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  20. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  1. 7th annual report 1998. UN ECE convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. [eds.

    1998-11-01

    The Integrated Monitoring Programme (ICP IM) is part of the Effects Monitoring Strategy under the UN ECE Long-Range Transboundary Air Pollution Convention. The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in the external environment. The monitoring and prediction of complex ecosystem effects on undisturbed reference areas require a continuous effort to improve the collection and assessment of data on the international scale. At the 1997 Task Force meeting it was decided that future annual reports from ICP IM would have a more technical character. The report could include some scientific material but also short technical descriptions of recent national activities and publications. Scientific articles should preferably be published in recognised scientific journals. The responsibility for producing annual reports would still lie on the Programme Centre, but more contributions from National Focal Points were welcomed. The content of the present Annual Report reflects the decisions of the Task Force meeting. The report gives a general overview of the ICP IM activities, the present content of the ICP IM database, and presents results from assessment activities carried out by several collaborating institutes and the ICP IM Programme Centre during the programme year 1997/98. The resources of the Programme Centre have been targeted to the revision of the Programme Manual and the EU/LIFE-project `Development of Assessment and Monitoring Techniques at Integrated Monitoring Sites in Europe`, which has limited the possibilities to carry out additional evaluations of ICP IM data. Section 1 is a short status report of the ICP IM activities, content of the IM database, including the contents of the GIS database, and the present geographical coverage of the monitoring network. Section 2 contains a report on multivariate gradient analysis applied to relate chemical and biological observations (prepared by D. de Zwart, RIVM

  2. A new ppb-gas analyzer by means of GC-ion mobility spectrometry (GC-IMS)

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    2003-01-01

    IMS-detectors are using beta-sources like tritium or nickel-63. This detection principle uses fast ion-molecular reactions between air cluster ions, produced by beta ionization and the analyte. The system works at normal pressure, the very high sensitivity and selectivity is used widely in industry, research, medicine and environmental control. In the last few years especially, small tritium sources were reduced to a level of some 50 MBq, which is 20 times less than the exemption levels for these sources. One of the handicaps of that technology is the problem of cross sensitivities. To overcome these problems a special GC-column of 1 m length has been included into the gas inlet and mixtures of compounds get separated by their retention times before entering the drift sensor. By means of that method a new analytical quality of IMS is arrived. The application of these analytical devices got a spin off in the last year. The main applications being discussed are as follows: (1) anti terror systems in buildings and facilities, (2) working place monitoring in chemical industry, (3) microelectronics: HF, HCl, Cl 2 , NMP, NH 3 , NO 2 , SO 2 , (4) environment: NH 3 , HCN, HCl, CH 2 O, organic compounds, SO 2 , NO 2 , (5) gas and petrol: gas-carottage, H 2 S, mercaptans, (6) household, furniture: solvents, clue, organic vapour from furniture, and (7) health care: diagnostics of various diseases. (author)

  3. Power-efficient method for IM-DD optical transmission of multiple OFDM signals.

    Science.gov (United States)

    Effenberger, Frank; Liu, Xiang

    2015-05-18

    We propose a power-efficient method for transmitting multiple frequency-division multiplexed (FDM) orthogonal frequency-division multiplexing (OFDM) signals in intensity-modulation direct-detection (IM-DD) optical systems. This method is based on quadratic soft clipping in combination with odd-only channel mapping. We show, both analytically and experimentally, that the proposed approach is capable of improving the power efficiency by about 3 dB as compared to conventional FDM OFDM signals under practical bias conditions, making it a viable solution in applications such as optical fiber-wireless integrated systems where both IM-DD optical transmission and OFDM signaling are important.

  4. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  5. IMS Learning Design Frequently Asked Questions

    NARCIS (Netherlands)

    Tattersall, Colin; Manderveld, Jocelyn; Hummel, Hans; Sloep, Peter; Koper, Rob; De Vries, Fred

    2004-01-01

    This list of frequently asked questions was composed on the basis of questions asked of the Educational Technology Expertise Centrum. The questions addessed are: Where can I find the IMS Learning Design Specification? What is meant by the phrase “Learning Design”? What is the IMS LD Specification

  6. Analytical evaluation of the operation data from selected PV-demonstration systems in the MuD-programme. Final report; Analytische Auswertung der Messergebnisse von ausgewaehlten PV-Demonstrationsanlagen im MuD-Programm. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Gabler, H. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Heinemann, D. [Oldenburg Univ. (Germany). Fachbereich 8 - Physik; Wiemken, E. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)

    1996-02-01

    From several PV-demonstration programmes, real performance data and the range in utilizing the systems are obtained. Nevertheless, for a particular system, no precise assessment and interpretation of the real system behaviour can be given: The quantification and the separation of the avoidable and of the unavoidable energy losses in the system is not to perform from the monitored data alone. Aim of this project was the interpretation of real operation data of PV-systems, the calculation of all steps of energy conversion and hence the determination of the energy losses in particular PV-systems as well as the presentation of a measure for energy production and system performance. This task includes a brief survey of the optimization potential of the energetic performance. The method choosen was an energy flow analysis, carried out on selected demonstration plants of the MuD-programme. For this reason, detailed simulation models were used. The results of the simulation calculations gives the measure to interprete the monitored system performance. In the course of the project, the analytical evaluation has shown a large ability in the assessment and interpretation of real system perforamances. Since the concept of the evaluation is transferable to many PV-systems, it represents a base for further applications in this field and in the field of the online-system control of PV-plants. (orig.) [Deutsch] In verschiedenen Demonstrationsprogrammen werden aus Langzeitmessungen Groessenordnung und Spannbreite der Nutzungsgrade photovoltaischer Anlagen ermittelt. Fuer eine spezifische Anlage ist damit jedoch keine praezise Einschaetzung bzw. Interpretation des Systemverhaltens moeglich, da die Quantifizierung der unvermeidbaren und der vermeidbaren Energieverluste im System nicht aus den Messdaten allein erfolgen kann. Ziel dieses Projektes war die Interpretation des reellen Betriebs von PV-Anlagen, die Berechnung der Zusammensetzung und der Bandbreite der Energieverluste im

  7. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  8. Data monitoring system of technical diagnosis system for EAST

    International Nuclear Information System (INIS)

    Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong

    2010-01-01

    Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)

  9. The JOYO remote monitoring system

    International Nuclear Information System (INIS)

    Damico, Joseph P.; Hashimoto, Yu

    2000-01-01

    The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)

  10. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  11. Establishing a Dynamic Database of Blue and Fin Whale Locations from Recordings at the IMS CTBTO hydro-acoustic network. The Baleakanta Project

    Science.gov (United States)

    Le Bras, R. J.; Kuzma, H.

    2013-12-01

    Falling as they do into the frequency range of continuously recording hydrophones (15-100Hz), blue and fin whale songs are a significant source of noise on the hydro-acoustic monitoring array of the International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). One researcher's noise, however, can be a very interesting signal in another field of study. The aim of the Baleakanta Project (www.baleakanta.org) is to flag and catalogue these songs, using the azimuth and slowness of the signal measured at multiple hydrophones to solve for the approximate location of singing whales. Applying techniques borrowed from human speaker identification, it may even be possible to recognize the songs of particular individuals. The result will be a dynamic database of whale locations and songs with known individuals noted. This database will be of great value to marine biologists studying cetaceans, as there is no existing dataset which spans the globe over many years (more than 15 years of data have been collected by the IMS). Current whale song datasets from other sources are limited to detections made on small, temporary listening devices. The IMS song catalogue will make it possible to study at least some aspects of the global migration patterns of whales, changes in their songs over time, and the habits of individuals. It is believed that about 10 blue whale 'cultures' exist with distinct vocal patterns; the IMS song catalogue will test that number. Results and a subset of the database (delayed in time to mitigate worries over whaling and harassment of the animals) will be released over the web. A traveling museum exhibit is planned which will not only educate the public about whale songs, but will also make the CTBTO and its achievements more widely known. As a testament to the public's enduring fascination with whales, initial funding for this project has been crowd-sourced through an internet campaign.

  12. Individualisierte Produkte im Fokus der intergrierten Produktentwicklung

    OpenAIRE

    Baumberger, C.;Gahr, A.

    2017-01-01

    Individualisierte Produkte stellen neue Herausforderungen an die Produktentwicklung – vornehmlich im Bereich der Produktstrukturplanung, der kundenindividuellen Produktadaption und dem Zielkostenmanagement. Diese Themen werden am Lehrstuhl für Produktentwicklung im Rahmen des Sonderforschungsbereiches 582 behandelt.

  13. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  14. Geschlechterstereotype im Einsatz

    Directory of Open Access Journals (Sweden)

    Erika Kegyes

    2007-11-01

    Full Text Available Die umfangreiche Monographie gehört zum Forschungsbereich der kritischen angewandten Linguistik (Critical Applied Linguistics und liegt sowohl theoretisch als auch praktisch im Schnittpunkt der gender- und werbesprachlichen Untersuchungen.

  15. Simplified demultiplexing scheme for two PDM-IM/DD systems utilizing a single Stokes analyzer over 25-km SMF.

    Science.gov (United States)

    Pan, Yan; Yan, Lianshan; Yi, Anlin; Jiang, Lin; Pan, Wei; Luo, Bin; Zou, Xihua

    2017-10-15

    We propose a four-linear state of polarization multiplexed intensity modulation and direct detection (IM/DD) scheme based on two orthogonal polarization division multiplexing (PDM) on-off keying systems. We also experimentally demonstrate a simple demultiplexing algorithm for this scheme by utilizing only a single Stokes analyzer. At the rate of 4×10  Gbit/s, the experimental results show that the power penalty of the proposed scheme is about 1.5 dB, compared to the single PDM-IM/DD for back-to-back (B2B) transmission. Compared to B2B, just about 1.7 dB power penalty is required after 25 km Corning LEAF optical fiber transmission. Meanwhile, the performance of the polarization tracking is evaluated, and the results show that the BER fluctuation is less than 0.5 dB with a polarization scrambling rate up to 708.75 deg/s.

  16. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  17. Toward an Intelligent Ion Mobility Spectrometer (IMS)

    International Nuclear Information System (INIS)

    McJunkin, Timothy R.; Scott, Jill R.; Miller, Carla J.

    2003-01-01

    The ultimate goal is to design and build a very smart ion mobility spectrometer (IMS) that can operate autonomously. To accomplish this, software capable of interpreting spectra so that it can be used in control loops for data interpretation as well as adjusting instrument parameters is being developed. Fuzzy logic and fuzzy numbers are used in this IMS spectra classification scheme. Fuzzy logic provides a straight forward method for developing a classification/detection system, whenever rules for classifying the spectra can be described linguistically. Instead of using 'max' and 'min' values, the product of the truth values is used to determine class membership. Using the product allows rule-bases that utilize the AND function to allow each condition to discount truth value in determining membership, while rule-bases with an OR function are allowed to accumulate membership. Fuzzy numbers allow encapsulation of the uncertainties due to ion mobility peak widths as well as measured instrumental parameters, such as pressure and temperature. Associating a peak with a value of uncertainty, in addition to making adjustments to the mobility calculation based on variations in measured parameters, enables unexpected shifts to be more reliably detected and accounted for; thereby, reducing the opportunity for 'false negative' results. The measure of uncertainty is anticipated to serve the additional purpose of diagnosing the operational conditions of the IMS instrument.

  18. Integrated Monitoring AWAReness Environment (IM-AWARE), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — American GNC Corporation (AGNC) and Louisiana Tech University (LaTECH) are proposing a significant breakthrough technology, the Integrated Monitoring AWAReness...

  19. Muriithi, IM

    African Journals Online (AJOL)

    Muriithi, IM. Vol 8, No 2 (2014) - Articles Correlation of magnetic resonance imaging findings with arthroscopy in the evaluation of rotator cuff pathology. Abstract PDF · Vol 8, No 2 (2014) - Articles Patterns of knee, hip and hand osteoarthritis in Kenyatta National Hospital Abstract PDF. ISSN: 1994-1072. AJOL African ...

  20. Effective information rates of single-carrier and multi-carrier modulation schemes for bandwidth constrained IM/DD systems

    KAUST Repository

    Mazahir, Sana

    2017-07-31

    Information-theoretic and signal processing aspects of some modulation schemes designed for intensity modulation/direct detection (IM/DD) optical wireless communication (OWC) systems are studied. Due to the constraints of IM/DD signals (non-negative real and baseband signals), the construction of these signals along with their time and frequency characteristics differ from their RF counterparts. This necessitates a careful study of such schemes under practical constraints. Three schemes are studied in this paper, namely, single carrier pulse amplitude modulation (SC-PAM), asymmetrically clipped optical OFDM (ACO-OFDM), and DC biased optical OFDM (DCO-OFDM). Our aim is to carry out a comparative study of these schemes in the presence of identical constraints on bandwidth and average optical power. The study reveals that the clipping operation required in ACO-OFDM significantly reduces its information rate, and as a result, it is outperformed by SC-PAM. Such a limitation does not apply to DCO-OFDM which has a higher information rate, even though part of the available optical power is expended in the non-information-bearing DC bias.

  1. Requirements for flexible learner monitoring

    NARCIS (Netherlands)

    Glahn, Christian; Specht, Marcus; Koper, Rob

    2007-01-01

    Glahn, C., Specht, M., & Koper, R. (2007). Requirements for flexible learner monitoring. In T. Navarette, J. Blat & R. Koper (Eds.). Proceedings of the 3rd TENCompetence Open Workshop 'Current Research on IMS Learning Design and Lifelong Competence Development Infrastructures' (pp. 89-96). June,

  2. Monitoring of streams: macrozoobenthos and accumulation of heavy metals and radionuclides in bottom sediments

    International Nuclear Information System (INIS)

    Arbaciauskas, K.; Mackeviciene, G.; Striupkuviene, N.; Motiejunas, S; Kreslauskaite, R.

    1998-01-01

    To evaluate the environmental quality of streams in integrated monitoring sites (IMS) and agrostations (AS), the macrozoobenthos communities and accumulation of heavy metals and radionuclides in bottom sediments were studied during 1993-1996. Samples of macrozoobenthos were collected in stream biotopes which were recommended for monitoring. Community biodiversity was assessed by Shannon-Wiener and Simpson indices, and water quality of streams was estimated by Trent and Mean Chandler biotic indices. Heavy metal (Pb, Cd, Cu, Cr, Ni, Mn) concentrations and radionuclide ( 137 Cs, 134 Cs, 40 K, 90 Sr) activity were determined in sediments. Macrozoobenthos communities indicated that the studied streams were clean waters. The heavy metal concentrations in surficial sediments showed annual and seasonal changes and differences between monitoring sites. The Cu concentration in the soft turfy stream sediments at the Aukstaitija IMS was twice as high as that in sediments of other monitoring streams with hard sandy-gravel bottoms. During 1994-1996, the Ni concentration decreased, while levels of Cu, Cd and Cr were relatively stable. The Pb concentrations decreased in all IMS, while those in AS increased. The concentration of 137 Cs was relatively stable in agrostation streams. Compared to levels in 1993, an increase of 137 Cs activity was observed in sediments at the Dzuklija IMS during 1995-1996. 90 Sr activity fluctuated in the monitoring sites from 1.6 to 3.7 Bq/kg dry weight. (author)

  3. Confidence in the use of information management and technology (IM and T) in radiography: Is age a barrier?

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Hywel, E-mail: rogershj1@cf.ac.u [Department of Radiography, School of Healthcare Studies, Cardiff University, Heath Park, Cardiff, CF14 4XN (United Kingdom); Pratt, Shaaron; Brown, Paul; Gambling, Tina [Department of Radiography, School of Healthcare Studies, Cardiff University, Heath Park, Cardiff, CF14 4XN (United Kingdom)

    2010-08-15

    Introduction: Age has been reported as a barrier to the use of Information Management and Technology (IM and T). Radiographers' confidence and ability in IM and T may be related to age and it is the aim of this research to investigate this relationship. Method: An online survey method gathered views from the radiographic population, between 31st August 2008 and 10th October 2008. The questionnaire encompassed IM and T ability, work based IM and T usage, personal IM and T usage, security and governance issues, education and training experience, the future and demographic details. For the purpose of this paper the first three sections and demographic section were considered. Results: Radiographers showed a good level of ability and confidence in the use of IM and T. Some general applications such as word processing showed a decreased confidence with age. Confidence in all radiography specific applications was scored highly although confidence in the use of Hospital Information Systems (HIS) and radiotherapy Treatment Planning Systems (TPS) showed the least confidence. Statistical analysis did not reveal a strong link between age and confidence in all applications. Discussion: While a link between age and confidence was not found in this study, frequency of use and training in IM and T require further investigation in relation to specific roles.

  4. Confidence in the use of information management and technology (IM and T) in radiography: Is age a barrier?

    International Nuclear Information System (INIS)

    Rogers, Hywel; Pratt, Shaaron; Brown, Paul; Gambling, Tina

    2010-01-01

    Introduction: Age has been reported as a barrier to the use of Information Management and Technology (IM and T). Radiographers' confidence and ability in IM and T may be related to age and it is the aim of this research to investigate this relationship. Method: An online survey method gathered views from the radiographic population, between 31st August 2008 and 10th October 2008. The questionnaire encompassed IM and T ability, work based IM and T usage, personal IM and T usage, security and governance issues, education and training experience, the future and demographic details. For the purpose of this paper the first three sections and demographic section were considered. Results: Radiographers showed a good level of ability and confidence in the use of IM and T. Some general applications such as word processing showed a decreased confidence with age. Confidence in all radiography specific applications was scored highly although confidence in the use of Hospital Information Systems (HIS) and radiotherapy Treatment Planning Systems (TPS) showed the least confidence. Statistical analysis did not reveal a strong link between age and confidence in all applications. Discussion: While a link between age and confidence was not found in this study, frequency of use and training in IM and T require further investigation in relation to specific roles.

  5. Bremssysteme im Personenkraftwagen

    Science.gov (United States)

    Reif, Konrad

    Für die ersten drei Punkte ist die Betriebsbremsanlage ("Fußbremse“) zuständig. Der Fahrer aktiviert sie durch Betätigen des Bremspedals. Die Feststellbremsanlage ("Handbremse“) hält das Fahrzeug im Stillstand.

  6. Support interoperability and reusability of emerging forms of assessment: Some issues on integrating IMS LD with IMS QTI

    NARCIS (Netherlands)

    Miao, Yongwu; Boon, Jo; Van der Klink, Marcel; Sloep, Peter; Koper, Rob

    2009-01-01

    Miao, Y., Boon, J., Van der Klink, M., Sloep, P. B., & Koper, R. (2011). Support interoperability and reusability of emerging forms of assessment: Some issues on integrating IMS LD with IMS QTI. In F. Lazarinis, S. Green, & E. Pearson (Eds.), E-Learning Standards and Interoperability: Frameworks

  7. Politische Inhalte im Internet: Angebot und Nachfrage politischer Inhalte im World Wide Web am Beispiel von Volksabstimmungen in der Schweiz

    OpenAIRE

    Rademacher, Patrick Horst Josef

    2010-01-01

    Welche Bedeutung kommt dem Internet in der Politikvermittlung zu? Dieser Frage geht Patrick Rademacher nach, indem er untersucht, welche Anbieter politische Inhalte im Internet zur Verfügung stellen, wie sie dabei vorgehen und wie die Struktur der Inhalte beschaffen ist. Darüber hinaus analysiert er, inwiefern die online angebotenen Inhalte auf eine Nachfrage durch die Bürger treffen. Im Untersuchungskontext von Volksabstimmungen in der Schweiz hat der Autor hierfür im Jahr 2008 umfangreiche ...

  8. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  9. Gruppenbezogene Menschenfeindlichkeit im Sport in Brandenburg

    OpenAIRE

    Delto, Hannes; Tzschoppe, Petra

    2016-01-01

    Mit der Querschnittsstudie "Wir und die Anderen – Gruppenbezogene Menschenfeindlichkeit im organisierten Sport in Brandenburg" wurde das Syndrom Gruppenbezogener Menschenfeindlichkeit im organisierten Sport untersucht. Das Konzept der Gruppenbezogenen Menschenfeindlichkeit – ausgehend von einer Ideologie der Ungleichwertigkeit – wurde von Prof. Wilhelm Heitmeyer (Universität Bielefeld) entwickelt. Die Ergebnisse ermöglichen explizite Aussagen über Ausmaß und Ursachen Gruppenbezogener Menschen...

  10. Verletzungen und Fehlbeanspruchungen im leistungsorientierten Rudersport

    OpenAIRE

    Bussian, Marc Robert

    2004-01-01

    Die Stellung der Breitensportart Rudern als gesundheitsfördernde Sportform ist in der Literatur gleichlautend positiv beschrieben. Im leistungsorientierten Rudersport müssen neben den Verletzungen und Fehlbeanspruchungen der eigentlichen Sportart die unabdingbaren Nebentrainingsformen berücksichtigt werden. In den neunziger Jahren vollzog sich ein trainingsmethodischer Wandel, die Einführung eines erschwinglichen Rudersimulators und eine technische Weiterentwicklung im Boots- und Ruderbau. Ei...

  11. Measurement of peripheral plasma using double probe in TRIAM-IM

    International Nuclear Information System (INIS)

    Yamagami, Masahiro; Kawasaki; Shoji; Jyotaki, Eriko; Fujita, Takaaki; Sakamoto, Mizuki; Nakamura, Kazuo; Nakamura, Yukio; Ito, Satoshi

    1994-01-01

    Behind the poloidal limiter of the TRIAM-IM, the change with time lapse of the electron temperature and the plasma density at the time of OH discharge was examined by using a double probe. Scrape-off plasma parameters, namely the correlations of electron temperature, plasma density and ion flux with main plasma parameters were obtained. It was found that scrape-off density is almost proportional to square of beam average electron density. Further, it was determined by calculation that the density on the outermost shell magnetic surface is about 1.5 x 10 15 /m 2 . In the TRIAM-IM, it is expected that accompanying the increase of plasma current at the time of OH discharge, the effects of thermal load and particle load given to the limiter and the first wall increase, and the increase of the metallic impurities due to sputtering becomes a serious problem. The merits of double probe method are explained. The objective of this experiment is to examine the temperature and density of the plasma that comes in contact with the limiter and the wall by determining the basic parameters of peripheral plasma at the time of OH discharge. In order to heighten the reliability of data, the examination was carried out from both aspects of hardware and software. The TRIAM-IM, double probe measuring system and its theory, applied voltage sweeping part, signal processing system, data processing system, and the experimental results of scrape-off layer parameters are described. (K.I.)

  12. Pengaruh Intensitas Mengakses Twitter Duta Im3 terhadap Kepuasan Pengalaman Adopsi dan Kepuasan Pengalaman Adopsi terhadap Keputusan Penggunaan Program Im3

    OpenAIRE

    Ayu Kinasih, Diyan Hafdinovianti; Pradekso, Tandiyo; Setiabudi, Djoko

    2014-01-01

    Nama : Diyan H Ayu KinasihNIM : D2C009029Judul : Pengaruh Intensitas Mengakses Twitter Duta IM3 terhadapKepuasan Pengalaman Adopsi dan Kepuasan PengalamanAdopsi terhadap Keputusan Penggunaan Program IM3ABSTRAKTwitter sebagai salah satu promotion tools yang digunakan oleh PTIndosat Tbk, diharapkan dapat memperkenalkan program-program serta eventyang dilakukan oleh Indosat. Melalui duta IM3 sebagai brand ambassador, Indosatmencoba meraih pasar anak muda dengan melakukan kegiatan promosi.Tipe pe...

  13. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  14. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  15. The Application of Internal Marketing (IM in a Service Organization

    Directory of Open Access Journals (Sweden)

    R. Sharma

    2013-07-01

    Findings and Strategic Implications. To complement earlier theoretical proposition on IM, the findings indicate that there are several empirical aspects such as “costs, people and concept” which hinder successful implementation of IM. This study proposes several strategic HR recommendations to reduce the “implementation gap” in IM such as to conduct continuous staff training on IM knowledge on regular time intervals, to reduce excessive work load and pressure and engaging staff members in continuous personal development sessions. In addition, the findings reveal that IM training should be given priority to solve “people-oriented” issues.

  16. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  17. A new screening instrument for disability in low-income and middle-income settings: application at the Iganga-Mayuge Demographic Surveillance System (IM-DSS), Uganda.

    Science.gov (United States)

    Bachani, Abdulgafoor M; Galiwango, Edward; Kadobera, Daniel; Bentley, Jacob A; Bishai, David; Wegener, Stephen; Hyder, Adnan A

    2014-12-19

    The measurement of disability in low-income countries is recognised as a major deficiency in health information systems, especially in Africa. The Iganga and Mayuge Demographic Surveillance System (IM-DSS) in Uganda provides a special opportunity to develop population-based data to inform national health policies and evaluate innovations in assessing the burden of disability in Uganda. In this study, we apply a new instrument to screen for physical disabilities at the IM-DSS. The study utilised a modified version of the short set of questions proposed by the Washington Group on Disability Statistics. The instrument was applied at the household level and information was collected on all individuals over the age of 5, who were residents of the IM-DSS. The study was based at the IM-DSS, which covers the parts of Iganga and Mayuge districts in Eastern Uganda. 57,247 individuals were included in the survey, with 51% of the study population being women. Activity limitations The overall prevalence of physical disability at the IM-DSS was 9.4%, with vision being the most common type of difficulty reported in this population, and communication being least prevalent. Disability was less likely to be observed among males than their female counterparts (OR 0.75; 95% CI 0.71 to 0.81; pdisability and increasing age, as well as disability and decreasing household wealth status. This study shows that the modified short set of questions can be readily applied in a DSS setting to obtain estimates on the prevalence and types of disability at the population level. This instrument could be adapted for use to screen for disability in other LMIC settings, providing estimates that are comparable across different global regions and populations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  19. Die Rule of Law im Völker- und im Europarecht – aktuelle Probleme

    Directory of Open Access Journals (Sweden)

    Helmut Tichy

    2015-04-01

    Full Text Available Diese am 5. März 2015 in Graz gehaltene Antrittsvorlesung eines Praxisprofessors, der im Hauptberuf Leiter des Völkerrechtsbüros im österreichischen Außenministerium ist, beschäftigt sich mit dem Begriff der Herrschaft des Rechts in den internationalen Beziehungen (Rule of Law und mit den Möglichkeiten Österreichs, zur Stärkung der Rule of Law und zur Lösung aktueller Probleme beizutragen. Dabei werden insbesondere die Mitwirkung an Kodifikationsbemühungen und an der Verbesserung der Einhaltung des humanitären Völkerrechts, die Umsetzung der Menschenrechte (auch in Österreich und Fragen der internationalen Gerichtsbarkeit angesprochen.

  20. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  1. Gruppenbezogene Menschenfeindlichkeit im Sport in Sachsen

    OpenAIRE

    Delto, Hannes; Tzschoppe, Petra

    2015-01-01

    Mit der Querschnittsstudie „Wir und die Anderen – Gruppenbezogene Menschenfeindlichkeit im organisierten Sport in Sachsen“ wurde erstmals das Syndrom Gruppenbezogener Menschenfeindlichkeit im organisierten Sport untersucht. Das Konzept der Gruppenbezogenen Menschenfeindlichkeit – ausgehend von einer Ideologie der Ungleichwertigkeit – wurde von Prof. Wilhelm Heitmeyer (Universität Bielefeld) entwickelt. Die Ergebnisse ermöglichen explizite Aussagen über Ausmaß und Ursachen Gruppenbezogener Men...

  2. Education and training issues in individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Dimitriou, P.; Kamenopoulou, V.

    2011-01-01

    The present article deals with the education and training (E and T) issues of individual monitoring (IM) of ionising radiation, based on the requirements provided by the Basic Safety Standards EURATOM Directive and the European Commission Technical Recommendations for IM of external radiation. The structure and the objectives of E and T programmes addressed to the staff of dosimetry services, in order to allow the recognition and ensure the continuity of expertise are discussed. The necessity for the establishment of a national strategy for building competence in IM through information, education, training and retraining programmes, addressed to the individually monitored personnel is underlined. The train the trainers' concept is recognised as being an important tool for optimising resources and transferring the skills necessary for building competence. The conditions under which an efficient train the trainers' approach can be established are discussed. Examples of curricula concerning the key persons involved in the provision of E and T in occupational radiation protection are also given. (authors)

  3. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  4. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  5. Anforderungen an ein System zur Dokumentanalyse im Unternehmenskontext : Integration von Datenbeständen, Aufbau- und Ablauforganisation

    OpenAIRE

    Baumann, Stephan; Hadj Ali, Majdi Ben; Lichter, Jürgen; Malburg, Michael; Meyer auf'm Hofe, Harald; Wenzel, Claudia

    1997-01-01

    Workflowmanagementsysteme werden im Bürobereich verstärkt zur effizienten Geschäftsprozeßabwicklung eingesetzt. Das bereits Mitte der 70er Jahre propagierte papierlose Büro bleibt jedoch gegenwärtig immer noch Utopie, da auch durch den allgegenwärtigen Einsatz von Computern im Bürobereich der Durchsatz an Schriftstücken nicht gesenkt wird. Insbesondere die Handhabung von papierintensiven Vorgängen ist in hohem Maße abhängig von einer Identifikation und Aufbereitung der in den Dokumenten e...

  6. NDIA 2018 IM and EM Technology Symposium: Innovative Insensitive Munition Solutions for Enhanced Warfighter Effectiveness

    Science.gov (United States)

    2018-04-26

    2018 IM & EM TECHNOLOGY SYMPOSIUM INNOVATIVE INSENSITIVE MUNITION SOLUTIONS FOR ENHANCED WARFIGHTER EFFECTIVENESS April 23 – 26, 2018 Doubletree by...IM & EM TECHNOLOGY SYMPOSIUM On behalf of the Insensitive Munitions and Energetic Materials Committee and our MSIAC partner, I would like to...welcome you to the 2018 Insensitive Munitions and Energetic Materials Technology Symposium. This international gathering of the top chemists, system

  7. Design and performance investigation of LDPC-coded upstream transmission systems in IM/DD OFDM-PONs

    Science.gov (United States)

    Gong, Xiaoxue; Guo, Lei; Wu, Jingjing; Ning, Zhaolong

    2016-12-01

    In Intensity-Modulation Direct-Detection (IM/DD) Orthogonal Frequency Division Multiplexing Passive Optical Networks (OFDM-PONs), aside from Subcarrier-to-Subcarrier Intermixing Interferences (SSII) induced by square-law detection, the same laser frequency for data sending from Optical Network Units (ONUs) results in ONU-to-ONU Beating Interferences (OOBI) at the receiver. To mitigate those interferences, we design a Low-Density Parity Check (LDPC)-coded and spectrum-efficient upstream transmission system. A theoretical channel model is also derived, in order to analyze the detrimental factors influencing system performances. Simulation results demonstrate that the receiver sensitivity is improved 3.4 dB and 2.5 dB under QPSK and 8QAM, respectively, after 100 km Standard Single-Mode Fiber (SSMF) transmission. Furthermore, the spectrum efficiency can be improved by about 50%.

  8. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  9. Midlatitude magnetometer chains during the IMS

    International Nuclear Information System (INIS)

    Mcpherron, R.L.

    1982-01-01

    The International Magnetospheric Study (IMS) is an international program to study global problems of magnetospheric dynamics. A key element of the U.S. participation in this program was the establishment of a ground magnetometer network. This network included a number of arrays at high and low latitudes. This report describes three chains established at midlatitudes, including the IMS Midlatitude Chain, the AFGL Magnetometer Network, and the Bell Lab Conjugate Array. Descriptions of the type of equipment, station locations, types of data display, and availability of data for each chain are presented in this report. A major problem of the data analysis phase of the IMS will be reducing selected subsets of these data to a common format. Currently, there are no plans to do this in a systematic manner

  10. Dialogic learning and interactive groups: an IMS LD template integrated in runtime systems

    Directory of Open Access Journals (Sweden)

    Mar Pérez-Sanagustín

    2008-07-01

    Full Text Available Dialogic learning and interactive groups have proved to be a useful educational methodological approach in lifelong learning with adults. The principles of this approach stress the importance of dialogue and equal participation in every stage of the learning process – including the design of the training activities. This paper adopts these principles as the basis for a configurable template that can be integrated in runtime systems. The template is formulated as a meta-UoL which can be interpreted by IMS Learning Design players. This template serves as a guide to flexibly select and edit the activities at runtime (on the fly. The meta-UoL has been used successfully by two significant practitioners so as to create a real-life example, with positive and encouraging results.

  11. 20th annual report 2011. Convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. (eds.)

    2011-07-01

    The Integrated Monitoring Programme (ICP IM) is part of the effect-oriented activities under the 1979 Convention on Long-range Transboundary Air Pollution, which covers the region of the United Nations Economic Commission for Europe (UNECE). The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in natural/semi natural ecosystems. This report summarizes the work carried out by the ICP IM Programme Centre and several collaborating institutes. The emphasis of the report is in the work done during the programme year 2010/2011 including: A short summary of previous data assessments, a status report of the ICP IM activities, content of the IM database, and geographical coverage of the monitoring network, a review of published vegetation results from ICP IM and preliminary analyses of collected vegetation data, a report on updated heavy metal budgets and critical loads at ICP IM sites, report on benefits of LTER collaboration (Long Term Ecological Research network, www.lter-europe.net), National Reports on ICP IM activities are presented as annexes. (orig.)

  12. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  13. Implantate im Mittelohrbereich - Teil 2 (Ergänzungen 2007)

    Science.gov (United States)

    Stieve, M.; Lenarz, Thomas

    In Deutschland leben ca. 12 Millionen Menschen, die an einer ein- oder beidseitigen Schwerhörigkeit leiden. Diese kann angeboren oder im Laufe des Lebens erworben sein. Klinisch und therapeutisch wichtig ist die Unterscheidung hinsichtlich des Schädigungsortes im Bereich des Mittelohres, d. h. eine Schalleitungsschwerhörigkeit, oder im Bereich des Innenohres, d. h. eine Schallempfindungsschwerhörigkeit, wobei hier der Schädigungsort auch am Hörnerven oder in den zentralen Hörabschnitten liegen kann. Therapeutisch lassen sich sowohl Schwerhörigkeiten im Bereich des Mittelohres als auch im Innenohr und sogar im Hirnstammbereich (Hirnstammimplantat) behandeln. 1,9 Millionen Schwerhörige haben eine Erkrankung im Mittelohrbereich, d. h. der Schall kann nur ungenügend auf das Innenohr übertragen werden. Die Ursache besteht meist in einer chronischen Mittelohrentzündung, die zu einer Zerstörung des Trommelfells und der Gehörknöchelchenkette geführt haben. Therapeutisch und damit als Prinzip der operativen Hörverbesserung steht primär der Verschluß des Trommelfells oder eine Rekonstruktion der Gehörknöchelchen. Mittelohroperationen werden mikrochirurgisch unter dem Operationsmikroskop durchgeführt, wobei zunächst durch eine sanierende Operation der Entzündungsprozeß entfernt wird und nach einer Ausheilungszeit die Gehörknöchelchenkette durch künstliche Prothesen rekonstruiert werden kann.

  14. Biological monitoring of blood toluene in exposed printing shop workers; Biologisches Monitoring von Toluol am Beispiel belasteter Druckereiarbeiter

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, K.D. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene; Pietsch, S. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene; Pfeiffer, E.H. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene

    1993-11-01

    42 toluene exposed printing workers were monitored and the results compared with those of a control group of 45 blood donors. Monitoring was done by means of blood toluene and hippuric acid excretion measurements. The mean indoor air concentration of toluene amounted to 230 mg/m{sup 3}. The blood toluene averaged up to 830 {mu}g/l. The median of hippuric acid excretion was in the range of 0,405 mg/mg creatinine for the control group and 1,938 mg/mg creatinine for the exposed group respectively. Hippuric acid showed a positive correlation toward ORSA-tube toluene measurements with good significance (p=0,000). Considerable high individual deviations in toluene metabolism occurred, and were discussed as a result of smoking and drinking behavior. (orig.) [Deutsch] 42 Druckereiarbeiter, die einer Raumluft mit einer mittleren Toluolkonzentration von 230 {mu}g/m{sup 3} exponiert waren, wurden untersucht und die Ergebnisse einer unbelasteten Kontrollgruppe bestehend aus 45 Blutspendern gegenuebergestellt. Als Parameter fuer ein biologisches Monitoring wurde die Blut-Toluolkonzentration und die Exkretion von Hippursaeure verwendet. Die Blut-Toluolkonzentration lag im Mittel bei 830 {mu}g/l. Der Mittelwert der Hippursaeure im Urin der unbelasteten Gruppe lag bei 0,405 mg/mg Kreatinin und der belasteten Gruppe bei 1,938 mg/mg Kreatinin. Die Hippursaeureausscheidung war hoch signifikant mit den Werten der ORSA-Roehrchen fuer die Luft-Toluolkonzentration korreliert (p=0,000). Erhebliche individuelle Abweichungen im Toluol-Metabolismus wurden deutlich und anhand von Rauch- und Trinkgewohnheiten diskutiert. (orig.)

  15. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  16. Radiation monitor system for nuclear power plants

    International Nuclear Information System (INIS)

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  17. Minería de imágenes

    OpenAIRE

    Fernández, Jacqueline; Miranda, Natalia Carolina; Guerrero, Roberto A.; Piccoli, María Fabiana

    2006-01-01

    Durante los últimos años, la proliferación de los medios digitales ha creado la necesidad del desarrollo de herramientas para la eficiente representación, acceso y recuperación de información visual. La minería de imágenes se ha convertido en una importante rama de investigación a causa del potencial que posee en descubrir patrones característicos a partir de un importante conjunto de imágenes. No obstante, la minería de imágenes es más que una simple extensión de la minería de datos al domin...

  18. Die Pluralbildung im Deutschen - ein Versuch im Rahmen der Optimalitätstheorie

    Directory of Open Access Journals (Sweden)

    Wegener, Heide

    1999-01-01

    Full Text Available Die Pluralbildung im Deutschen ist nicht chaotisch, aber komplex. Unabhängig davon, ob man für die Pluralbildung Regeln, Schemata oder die Wortstruktur als Erklärungsmodell benutzt, bleibt die Tatsache einer beachtlichen Zahl miteinander konkurrierender Formen zu erklären. Dies gilt schon deshalb, weil die Variation unter den Pluralformen wohl mit dazu beiträgt, dass trotz der Arbeiten von Mugdan 1977 und Köpcke 1987, 1993, der klaren Darstellung des Pluralsystems in vielen Grammatiken, z.B. Eisenberg 1986, 1989, 1998 noch immer bisweilen die Meinung besteht, die Pluralbildung im Deutschen sei arbiträr.Es soll gezeigt werden, dass das Pluralsystem des Deutschen nach Beschränkungen aufgebaut ist, die morphologischer und silbenphonologischer Natur sind und sich im Rahmen der Optimalitätstheorie (OT beschreiben lassen. Die OT nimmt an, dass Wortformen universalen Beschränkungen (Constraints unterliegen, und dass diese prinzipiell verletzbar sind. Ich werde zunächst die für die Pluralbildung relevanten Beschränkungen definieren, dann an heimischen Pluralformen und -varianten ihr Zusammenwirken zeigen und schließlich den Assimilationsprozess von Fremdwörtern mit Hilfe dieser Beschränkungen und der Beschränkungshierarchien zu erklären versuchen. Daran werden schließlich Überlegungen zu Verarbeitung und Lernbarkeit der Pluralformen geknüpft.

  19. How IMS Enables Converged Services for Cable and 3G Technologies: A Survey

    Directory of Open Access Journals (Sweden)

    Noël Crespi

    2008-04-01

    Full Text Available The IP multimedia subsystem (IMS is a service control overlay standardized by the 3GPP. The IMS is based on session initiation protocol (SIP to establish, modify, and terminate the sessions. It provides a clean separation between services, signaling, and media with the potential to enable control and management of services over multiple transport technologies. In the scope of fixed-mobile convergence, this paper is dedicated to presenting a review of how cable networks can be integrated into IMS technology to achieve 3G-cable horizontal convergence. Cable networks, as one of the major fixed broadband access technologies with PacketCable architecture, are able to provide broadband internet access and VoIP in addition to cable TV. In this article, we review the evolution in PacketCable architecture to take up IMS. In this way, we consider the standardization and research activities to address this integration. We review some important challenges such as SIP protocol compatibility, defining unique user profile, required enhancement in authentication process, QoS and charging system.

  20. How IMS Enables Converged Services for Cable and 3G Technologies: A Survey

    Directory of Open Access Journals (Sweden)

    Mani Mehdi

    2008-01-01

    Full Text Available The IP multimedia subsystem (IMS is a service control overlay standardized by the 3GPP. The IMS is based on session initiation protocol (SIP to establish, modify, and terminate the sessions. It provides a clean separation between services, signaling, and media with the potential to enable control and management of services over multiple transport technologies. In the scope of fixed-mobile convergence, this paper is dedicated to presenting a review of how cable networks can be integrated into IMS technology to achieve 3G-cable horizontal convergence. Cable networks, as one of the major fixed broadband access technologies with PacketCable architecture, are able to provide broadband internet access and VoIP in addition to cable TV. In this article, we review the evolution in PacketCable architecture to take up IMS. In this way, we consider the standardization and research activities to address this integration. We review some important challenges such as SIP protocol compatibility, defining unique user profile, required enhancement in authentication process, QoS and charging system.

  1. Medienerziehung im Vorschulbereich - Zum Projekt Mediengarten der Wiener Medienpädagogik

    Directory of Open Access Journals (Sweden)

    Gudrun Kern

    2010-09-01

    Full Text Available Im Zuge des Projekts Mediengarten der Wiener Medienpädagogik wurde in Kooperation mit angehenden KindergartenpädagogInnen eine Medienerziehung im Sinne einer Auseinandersetzung über Medien im Vorschulbereich anhand konkreter Angebote in Kindergärten konzipiert. Im folgenden Artikel werden die Schwerpunktsetzungen dieses Konzepts vorgestellt und durch praktische Beispiele verdeutlicht.

  2. Cyberbullying und Empathie : affektive, kognitive und medienbasierte Empathie im Kontext von Cyberbullying im Kindes- und Jugendalter

    OpenAIRE

    Pfetsch, Jan; Müller, Christin R.; Ittel, Angela

    2014-01-01

    "Bei medial vermittelter Kommunikation sinkt sowohl die Hemmschwelle für aggressive Verhaltensweisen wie Cyberbullying als auch die Wahrscheinlichkeit empathischer Reaktionen. Im Fokus der vorliegenden Studie mit 979 Schülerinnen und Schülern der 4.-8. Klassen (M=12.01, SD=1.68 Jahre, 55% weiblich) stand die Frage, ob Cyberbullies geringere Ausprägungen für affektive, kognitive und medienbasierte Empathie aufweisen als Unbeteiligte. Empathie wurde im Selbst- und Peerbericht erhoben. Hypothese...

  3. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  4. A Grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  5. A grid job monitoring system

    International Nuclear Information System (INIS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  6. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  7. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  8. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  9. GTA Beamloss-Monitor System

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper

  10. GTA beamloss-monitor system

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref

  11. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  12. Instrumentale Spielformeln und Vokale Verzierungen im 16.Jahrhundert

    Directory of Open Access Journals (Sweden)

    Göllner, Theodor

    2001-12-01

    Full Text Available In the music of the 16th century, stereotype four-note formulas are found in the instrumental as well as in the vocal idiom. Although frequently identical in appearance, their functions are very different. While indispensable in the instrumental idiom, particularly in keyboard music, where they represent the very essence of instruction in 15th-century organ treatises and fundamenta, they appear in vocal music only as additions to finished compositions or existing practices. What amounts to an absolute necessity in one case is merely an ornamental supplement in the other. In vocal music it is treated as a matter of performance carried out by a qualified soloist and limited to the musical centers of Italy. The present article raises the question as to how the genuinely instrumental and widely spread keyboard practice made its impact on the vocal ornaments of the singer, whose primary concern is the musical communication of language.

    [de] Die in der Musik des 16. Jahrhunderts im Instrumentalen wie im Vokalen vorkommenden, meist viertönigen, stereotypen Formeln sind zwar in beiden Bereichen weitgehend identisch, doch von höchst unterschiedlicher Funktion. Während sie im Instrumentalen, besonders in der Tastenmusik, unverzichtbar sind und schon im 15. Jahrhundert den Kern der Orgeltraktate und Fundamenta bilden, treten sie im Vokalen zu einer fertigen Komposition oder bestehenden Praxis hinzu. Was im einen Fall eine unbedingte Notwendigkeit ist, wird im anderen zu einem nachträglichen Ornament, das sich oft erst bei der Aufftührung einstellt, den qualifizierten Solosänger voraussetzt und auf die musikalischen Zentren Italiens konzentriert war. Der Artikel versucht zu klären, wie sich das genuin instrumentale, allgemein verbreitete Tastenspiel auf die spezielle Verzierungskunst des Sängers auswirkt, dessen primäre Aufgabe es ist, Sprache musikalisch zu vermitteln.

  13. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  14. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  15. Development of a plug-type IMS-MS instrument and its applications in resolving problems existing in in-situ detection of illicit drugs and explosives by IMS.

    Science.gov (United States)

    Du, Zhenxia; Sun, Tangqiang; Zhao, Jianan; Wang, Di; Zhang, Zhongxia; Yu, Wenlian

    2018-07-01

    Ion mobility spectrometry (IMS) which acts as a rapid analysis technique is widely used in the field detection of illicit drugs and explosives. Due to limited separation abilities of the pint-sized IMS challenges and problems still exist regarding high false positive and false negative responses due to the interference of the matrix. In addition, the gas-phase ion chemistry and special phenomena in the IMS spectra, such one substance showing two peaks, were not identified unambiguously. In order to explain or resolve these questions, in this paper, an ion mobility spectrometry was coupled to a mass spectrometry (IMS-MS). A commercial IMS is embedded in a custom-built ion chamber shell was attached to the mass spectrometer. The faraday plate of IMS was fabricated with a hole for the ions to passing through to the mass spectrometer. The ion transmission efficiency of IMS-MS was optimized by optimizing the various parameters, especially the distance between the faraday plate and the cone of mass spectrum. This design keeps the integrity of the two original instruments and the mass spectrometry still works with multimode ionization source (i.e., IMS-MS, ESI-MS, APCI-MS modes). The illicit drugs and explosive samples were analyzed by the IMS-MS with 63 Ni source. The results showed that the IMS-MS is of high sensitivity. The ionization mechanism of the illicit drug and explosive samples with 63 Ni source were systematically studied. In addition, the interferent which interfered the detection of cocaine was identified as dibutyl phthalate (DBP) by this platform. The reason why the acetone solution of amphetamine showed two peaks was explained. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. A Management Tool for Improvement (Improving) IMS Stations Performance

    International Nuclear Information System (INIS)

    Mohammad, D.; Pantin, A.; Quintana, E.

    2011-01-01

    IMS-Maintenance is a software under development by the personnel of ARN-CTBT office, intended for the technical management of IMS stations under ARN's responsibility. This software integrates the whole control of the equipment in an IMS station, including the management of consumables used in daily or periodic operation. It permits an easy retrieval (access) of the technical features, suppliers, etc. of each item of the equipment, as well as its maintenance history and scheduled task. Although this project is still in a starting phase, a preliminary version of this software is being used in radionuclide station RN01 (Buenos Aires), having already demonstrated its usefulness and potential for the improvement of IMS station management. (authors)

  17. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  18. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  19. Hanger-type laundry monitor system

    International Nuclear Information System (INIS)

    Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro

    1987-01-01

    Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)

  20. Storage monitoring systems for the year 2000

    International Nuclear Information System (INIS)

    Nilsen, C.; Pollock, R.

    1997-01-01

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000

  1. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  2. The future of the IMS Learning Design specification: a critical look

    NARCIS (Netherlands)

    Sloep, Peter

    2009-01-01

    P. B. Sloep (2009). The future of the IMS Learning Design specification: a critical look. Presentation at the IMS Learning Design seminar 'The future of IMS Learning Design'. December, 10, 2009, Wollongong, Australia: University of Wollongong.

  3. Plant-wide integrated equipment monitoring and analysis system

    International Nuclear Information System (INIS)

    Morimoto, C.N.; Hunter, T.A.; Chiang, S.C.

    2004-01-01

    A nuclear power plant equipment monitoring system monitors plant equipment and reports deteriorating equipment conditions. The more advanced equipment monitoring systems can also provide information for understanding the symptoms and diagnosing the root cause of a problem. Maximizing the equipment availability and minimizing or eliminating consequential damages are the ultimate goals of equipment monitoring systems. GE Integrated Equipment Monitoring System (GEIEMS) is designed as an integrated intelligent monitoring and analysis system for plant-wide application for BWR plants. This approach reduces system maintenance efforts and equipment monitoring costs and provides information for integrated planning. This paper describes GEIEMS and how the current system is being upgraded to meet General Electric's vision for plant-wide decision support. (author)

  4. Im Wind / Mari Vallisoo ; tõlk. Gisbert Jänicke

    Index Scriptorium Estoniae

    Vallisoo, Mari, 1950-2013

    2003-01-01

    Sisu: Im Wind = Tuulega ; Zwei Frauen = Kaks naist ; In Gedanken an Aleksander Levin = aleksander Levinile mõteldes ; Jetzt im Dunkel = Nüüd pimedas ; Fragen = Küsimused ; Der Zwillingsbruder = Kaksikvend

  5. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  6. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  7. Utilization scenarios for driving support systems in cargo traffic and their evaluation; Einsatzszenarien fuer Fahrerassistenzsysteme im Gueterverkehr und deren Bewertung

    Energy Technology Data Exchange (ETDEWEB)

    Henning, K.; Preuschoff, E. (eds.)

    2003-07-01

    The report presents a summary of the project of the above title (EFAS project). While earlier projects focused on the technical side, EFAS is the first to present a systematic analysis, presentation and evaluation of the parameters influencing driving support systems. With the aid of a systemic analysis, the key influencing factors are defined and analyzed, and three scenarios are developed which take account of user-oriented, organizational, operational, technical, infrastructural and legal aspects. The scenarios are evaluated with the aid of driving and traffic simulations in the fields of humans, organization and technology, and actions are recommended on this basis for driving support systems in cargo transport. [German] Der Bericht fasst die Ergebnisse des Projektes ''Einsatzszenarien fuer Fahrerassistenzsysteme im Gueterverkehr'' (EFAS) zusammen. Bisher wurde die Thematik Fahrerassistenzsysteme hauptsaechlich auf der Seite der Fahrzeugtechnik vorangetrieben. Das Projekt EFAS stellt nun zum ersten Mal eine umfassende Analyse, Darstellung und Bewertung dar. Mit Hilfe einer systemischen Analyse werden die wesentlichen Einflussfaktoren fuer die Einbindung von Fahrerassistenzsystemen in das Gesamtsystem ''Verkehr'' bestimmt und untersucht. Hieraus werden drei Einsatzszenarien entwickelt, die nutzerbezogene, organisatorische, betriebliche, fahrzeugtechnische, infrastukturelle und rechtliche Aspekte zu Zukunftsbildern zusammenfuegen. Die Szenarien werden mit Hilfe von Fahr- und Verkehrssimulationen in den Bereichen Mensch, Organisation und Technik bewertet. Aus den Ergebnissen werden konkrete Handlungsempfehlungen fuer den Einsatz von Fahrerassistenzsystemen im Strassengueterverkehr abgeleitet. (orig.)

  8. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  9. Unmanned observatory for auroral physics study on the Antarctic Continent-Multipoint ground-based observations during the IMS period (1976-1978-

    Directory of Open Access Journals (Sweden)

    Masaru Ayukawa

    1999-07-01

    Full Text Available The International Magnetospheric Study (IMS was carried out for three years from 1976. The Japanese Antarctic Research Expedition (JARE participated in this IMS project. The main purpose of the IMS project in JARE was the synthetic observation of polar magnetic substorms. In order to study polar magnetic substorms, a multipoint ground observation network was planned around Syowa, including unmanned stations. In the construction of an unmanned observatory system in Antarctica, there have been difficulties, such as insuffcient information about enviromental conditions, the construction support capability, power supply and others. During the IMS period, the U. S. A., former Soviet Union, Australia and the United Kingdom also started to develop unmanned observation systems. In this report, we describe the development of a JARE unmanned observatory for upper atmosphere physics and also the scientific results.

  10. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  11. The trans-unit operation management system of VEAG AG`s power plant in Jaenschwalde; Das werksuebergreifende Betriebsmanagementsystem im Kraftwerk Jaenschwalde der VEAG AG

    Energy Technology Data Exchange (ETDEWEB)

    Weidich, H.; Platzke, R.

    1997-12-31

    Jaenschwalde coal power plant consists of 3 so-called ``modules`` of 2 power blocks each. The new operation management system at Jaenschwalde power plant has greatly improved the temporal availability and quality of process data needed by its various departments. The possibilities of process data analysis and the various optional extensions are capable of integration in various ways and at reasonable cost. At present the operation management system is managed by two employees. As the job does not even fully occupy these two, they are available for other work as well. In earlier times there were instead 6 process computers whose operation and maintenance occupied 30 employees. Beside these tremendous savings in labour the system has also brought about great functional improvements in terms of the supply of process data for the power plant as a whole and also for the entire VEAG network. [Deutsch] Das Braunkohlekraftwerk Jaenschwalde besteht aus insgesamt 6 Kraftwerksbloecken, von denen jeweils 2 Kraftwerksbloecke sogenannte `Module` bilden. Die zeitliche Verfuegbarkeit und die Guete der von den Fachabteilungen benoetigten Prozessdaten ist durch das neue Betriebsmanagementsystem im Kraftwerk Jaenschwalde drastisch erhoeht worden. Die Moeglichkeiten der Prozessdatenanalyse und die individuellen Erweiterungen sind vielseitig und mit einem ueberschaubaren Aufwand integrierbar. Die Pflege des gesamten heutigen Betriebsmanagementsystems wird heute von 2 Personen durchgefuehrt, die nicht einmal 100% ihrer Arbeitszeit dafuer aufzuwenden haben, so dass sie noch Aufgaben aus anderen Bereichen erledigen koennen. Frueher wurden dagegen 30 Personen fuer die Pflege und Wartung der 6 Prozessrechner benoetigt. Neben dem Einsparungspotential wurde eine grosse funktionelle Verbesserung fuer die Bereitstellung der Prozessdaten im gesamten Kraftwerk und darueber hinaus im gesamten VEAG-Netzwerk erreicht. (orig./RHM)

  12. Remote supervision of GIS monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)

    2007-07-01

    Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.

  13. Transplantate und Implantate im Mittelohrbereich - Teil 1 (Stand 2002)

    Science.gov (United States)

    Kempf, Hans-Georg; Lenarz, Thomas; Eckert, Karl-Ludwig

    In Deutschland leben ungefähr 12 Millionen Menschen, die an einer ein- oder beidseitigen Schwerhörigkeit leiden. Diese kann angeboren oder im Laufe des Lebens erworben sein. Klinisch und therapeutisch wichtig ist die Unterscheidung, ob die Ursache der Schwerhörigkeit im Bereich des Mittelohres, d. h. der Schallübertragung, oder im Bereich des Innenohres, der Hörnerven und der zentralen Hörbahnabschnitte, d. h. der Schallempfindung, liegt. 2,5 Millionen Schwerhörige haben dabei das Problem der Schallübertragung, d.h. die Störung liegt im Mittelohrbereich, und hier kann man in der Regel mit operativen, mikrochirurgisch durchgeführten Massnahmen helfen [1, 2]. Im Vordergrund steht als Ursache hier die chronische Mittelohrentzündung, die sich als Perforation des Trommelfells, als Defekt oder Unterbrechung der Gehörknöchelchen oder auch als Cholesteatom, einer sogenannte Knocheneiterung äussern kann [3]. Therapeutisch und damit als Prinzip der operativen Hörverbesserung steht primär der Verschluss des Trommelfells oder eine Rekonstruktion der Gehörknöchelchen an.

  14. System of message for gamma-radiation monitor

    International Nuclear Information System (INIS)

    Bolic, M.D.; Koturovic, A.M.

    2001-01-01

    Paper describes a system of voice messages for gamma-radiation monitor based on PC. The systems reproduces recorded messages that is simpler than the process of their synthesis. Message choice is based on combination of recorded digital results and/or received reference messages or warnings. The system of generation of voice messages applies the Windows based software. The total memory array required to create independent voice system is maximum 1.7 mbyte. The monitor may be used for continuous monitoring of radioactivity level with 5-8 s period of message repetition. Another option of the system operation is based on monitor application for the environment monitoring. Period of messages in this case is equal to 5-30 min [ru

  15. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  16. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  17. Gruppenbezogene Menschenfeindlichkeit im Sport in Sachsen-Anhalt

    OpenAIRE

    Delto, Hannes; Tzschoppe, Petra

    2016-01-01

    Mit der Querschnittsstudie „Wir und die Anderen – Gruppenbezogene Menschenfeindlichkeit im organisierten Sport in Sachsen-Anhalt“ wurde das Syndrom Gruppenbezogener Menschenfeindlichkeit im organisierten Sport untersucht. Das Konzept der Gruppenbezogenen Menschenfeindlichkeit – ausgehend von einer Ideologie der Ungleichwertigkeit – wurde von Prof. Wilhelm Heitmeyer (Universität Bielefeld) entwickelt. Die Ergebnisse ermöglichen explizite Aussagen über Ausmaß und Ursachen Gruppenbezogener Mensc...

  18. Simple routine tests to improve the performance of the DPRSN TLD-based individual monitoring system

    International Nuclear Information System (INIS)

    Alves, J.G.; Batel, V.I.; Silva, P.B.; Roda, A.; Santos, L.

    2002-01-01

    This paper presents some of the results of a simple quality control program developed and implemented at the thermoluminescence sector of the IMS. The European Union (EU) Directive 96/29/EURATOM has not yet been transposed to national legislation and Portuguese law concerning the monitoring of radiation workers still establishes an annual dose limit of 50 mSv. However, new legislation has recently been published with requirements on the performance of dosimetric services. Some of the results of the tests reported herein will show compliance with the above mentioned requirements

  19. Integrated circuit devices in control systems of coal mining complexes

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Systems of automatic monitoring and control of coal mining complexes developed in the 1960's used electromagnetic relays, thyristors, and flip-flops on transistors of varying conductivity. The circuits' designers, devoted much attention to ensuring spark safety, lowering power consumption, and raising noise immunity and repairability of functional devices. The fast development of integrated circuitry led to the use of microelectronic components in most devices of mine automation. An analysis of specifications and experimental research into integrated circuits (IMS) shows that the series K 176 IMS components made by CMOS technology best meet mine conditions of operation. The use of IMS devices under mine conditions has demonstrated their high reliability. Further development of integrated circuitry involve using microprocessors and microcomputers. (SC)

  20. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  1. Freie Lerninhalte im Internet mit Studierenden recherchieren, kommentieren und kompilieren. Zur Gestaltung der online-Selbstlernangebote im hr-Funkkolleg Philosophie

    Directory of Open Access Journals (Sweden)

    Jakob Krebs

    2017-03-01

    Full Text Available Wie lassen sich online frei verfügbare Bildungsinhalte mit Studierenden so zusammenstellen, dass sie als thematisch sortierte Selbstlernmaterialien unkompliziert gefunden werden können – sei es von anderen Studierenden, interessierten Laien oder auch von Lehrkräften in Bildungsinstitutionen? Der vorliegende Werkstattbericht rekonstruiert ein Lernszenario, in dem Studierende vorhandene Materialien im Internet recherchierten, kommentierten und kompilierten, um ein Online-Zusatzangebot zu den Radiosendungen im hr-Funkkolleg Philosophie 2014/15 zu erstellen. Die Rahmenbedingungen dieser ungewöhnlichen universitären Kooperation mit dem Rundfunk werden im ersten Abschnitt vorgestellt. Der zweite Abschnitt skizziert das didaktische Design zusammen mit dem Projektstrukturplan eines produktorientierten kollaborativen Lernsettings mit Wiki-Einsatz. Im dritten Abschnitt werden der Lernerfolg bei den Studierenden sowie einige Herausforderungen benannt, die u. a. in der Abschlussevaluierung zur Sprache kamen. Der vierte Abschnitt macht die Projekterfahrungen für reguläre Lehr- und Lern-Szenarien fruchtbar, in denen nicht nur Studierende mit didaktischen Interessen durch die gemeinsame Gestaltung von Internetangeboten fachlich und methodisch profitieren können. Mit dem Bericht wird somit u. a. veranschaulicht, wie sich Ansätze von Blended, Peer-Assisted und Service Learning produktiv kombinieren lassen.

  2. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  3. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  4. Thermische Verletzungen im Kindesalter: Eine retrospektive Kohortenstudie von 212 Fällen

    OpenAIRE

    Sperling, Patrik Leonhart

    2012-01-01

    Anhand einer retrospektiven Datenanalyse sollen Verteilungsmuster von Verbrennungen und Verbrühungen bezogen auf Alter und Geschlecht untersucht werden. Erfasst wurden 212 Patienten im Alter von 0 bis 16 Jahren betrachtet, die im Zeitraum vom 01.01.2004 bis zum 31.12.2009 auf Grund einer thermischen Verletzung stationär im Universitätsklinikum Würzburg der Julius-Maximilians-Universität Würzburg behandelt wurden. Den größten Anteil thermischer Verletzungen im Kindesalter stellen Verbrühungen ...

  5. Sequence-specific DNA alkylation by tandem Py-Im polyamide conjugates.

    Science.gov (United States)

    Taylor, Rhys Dylan; Kawamoto, Yusuke; Hashiya, Kaori; Bando, Toshikazu; Sugiyama, Hiroshi

    2014-09-01

    Tandem N-methylpyrrole-N-methylimidazole (Py-Im) polyamides with good sequence-specific DNA-alkylating activities have been designed and synthesized. Three alkylating tandem Py-Im polyamides with different linkers, which each contained the same moiety for the recognition of a 10 bp DNA sequence, were evaluated for their reactivity and selectivity by DNA alkylation, using high-resolution denaturing gel electrophoresis. All three conjugates displayed high reactivities for the target sequence. In particular, polyamide 1, which contained a β-alanine linker, displayed the most-selective sequence-specific alkylation towards the target 10 bp DNA sequence. The tandem Py-Im polyamide conjugates displayed greater sequence-specific DNA alkylation than conventional hairpin Py-Im polyamide conjugates (4 and 5). For further research, the design of tandem Py-Im polyamide conjugates could play an important role in targeting specific gene sequences. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Drinking-water monitoring systems

    International Nuclear Information System (INIS)

    1994-01-01

    A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission

  7. Oil spill statistics and oil spill monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Viebahn, C. von [Greifswald Univ. (Germany). Dept. of Geography

    2001-09-01

    The main parts of the report describe the analysis and it's results of German and international oil spill data (North Sea and Baltic Sea). In order to improve the current oil spill monitoring of the Baltic Sea regarding oil spill data, the report proposes the establishment of a combined monitoring system; its suitability is shown on selected examples. This contains today's pollution control aircraft plus in-service aircraft and satellites. (orig.) [German] Der Schwerpunkt der Arbeit liegt in der Analyse von Daten ueber marine Oelschadensfaelle in deutschen und internationalen Gewaessern (Nord- und Ostsee). Um die heutige Ueberwachung der Ostsee im Hinblick auf Oelschadensfaelle zu verbessern, wird die Einrichtung eines kombinierten Ueberwachungssystems vorgeschlagen und dessen Eignung an ausgewaehlten Beispielen dargestellt. Dieses umfasst sowohl die heute eingesetzten Ueberwachungsflugzeuge sowie zusaetzlich Linienflugzeuge und Satelliten. (orig.)

  8. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  9. Design of an online charging system to support IMS-based inter-domain composite services

    NARCIS (Netherlands)

    Le, V.M.; Huitema, G.B.; Rumph, F.J.; Nieuwenhuis, Lambertus Johannes Maria; van Beijnum, Bernhard J.F.; Pfeifer, T.; Bellavista, P.

    2009-01-01

    For service providers online charging of composite services is necessary in order to manage financial risks of service delivery in multi-domain environments. At service level, inter-domain composite services consist of one or more service components, e.g. access service, IMS communication service or

  10. Calibración de imágenes de radares meteorológicos

    Directory of Open Access Journals (Sweden)

    Virgilio Santander Socorras Quintero

    2014-04-01

    Full Text Available En este documento se ilustran las técnicas de fusión de imágenes para complementar y calibrar la información meteorológica presente en imágenes de radares terrestres con el uso de imágenes satelitales meteorológicas. Para realizar la calibración de las imágenes de radares terrestres se implementó un método de fusión de imágenes basado en la herramienta matemática transformada wavelet discreta. Ya que existe una familia de wavelets, es necesario determinar cuál wavelet ofrece el mejor resultado; para esto se determina la correlación existente entre los resultados de fusión de diferentes wavelets y las imágenes uti-lizadas en cada fusión. Se define una metodología para selección de umbral global de segmentación y una metodología para realizar la calibración de las imágenes de radares terrestres. Siguiendo la metodología de calibración de imágenes, se generan algunos resultados y se muestran sus ventajas.

  11. Hybrid intelligent monironing systems for thermal power plant trips

    Science.gov (United States)

    Barsoum, Nader; Ismail, Firas Basim

    2012-11-01

    Steam boiler is one of the main equipment in thermal power plants. If the steam boiler trips it may lead to entire shutdown of the plant, which is economically burdensome. Early boiler trips monitoring is crucial to maintain normal and safe operational conditions. In the present work two artificial intelligent monitoring systems specialized in boiler trips have been proposed and coded within the MATLAB environment. The training and validation of the two systems has been performed using real operational data captured from the plant control system of selected power plant. An integrated plant data preparation framework for seven boiler trips with related operational variables has been proposed for IMSs data analysis. The first IMS represents the use of pure Artificial Neural Network system for boiler trip detection. All seven boiler trips under consideration have been detected by IMSs before or at the same time of the plant control system. The second IMS represents the use of Genetic Algorithms and Artificial Neural Networks as a hybrid intelligent system. A slightly lower root mean square error was observed in the second system which reveals that the hybrid intelligent system performed better than the pure neural network system. Also, the optimal selection of the most influencing variables performed successfully by the hybrid intelligent system.

  12. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  13. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  14. AirNow Information Management System - Global Earth Observation System of Systems Data Processor for Real-Time Air Quality Data Products

    Science.gov (United States)

    Haderman, M.; Dye, T. S.; White, J. E.; Dickerson, P.; Pasch, A. N.; Miller, D. S.; Chan, A. C.

    2012-12-01

    (ASDP) was recently developed to merge PM2.5 estimates from National Aeronautics and Space Administration (NASA) satellite data and AirNow observational data, creating more precise maps and gridded data products for under-monitored areas. The ASDP can easily incorporate other data feeds, including fire and smoke locations, to build enhanced real-time air quality data products. In this presentation, we provide an overview of the features and functions of IMS, an explanation of how data moves through IMS, the rationale of the system architecture, and highlights of the ASDP as an example of the modularity and scalability of IMS.

  15. Critical function monitoring system algorithm development

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1984-01-01

    Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms

  16. 22nd annual report 2013. Convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. (eds.)

    2013-09-01

    The Integrated Monitoring Programme (ICP IM) is part of the effect-oriented activities under the 1979 Convention on Long-range Transboundary Air Pollution, which covers the region of the United Nations Economic Commission for Europe (UNECE). The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in natural/semi natural ecosystems. This report summarizes the work carried out by the ICP IM Programme Centre and several collaborating institutes. The emphasis of the report is in the work done during the programme year 2012/2013 including: A short summary of previous data assessments; A status report of the ICP IM activities, content of the IM database, and geographical coverage of the monitoring network; A final report on relations between vegetation changes and nitrogen Critical Load exceedance; A progress report on base line heavy metal approach, estimation of the extent of metal turnover in European forest catchments over the last decades; A final report on sulphur and nitrogen input-output budgets at ICP IM sites in Europe; National Reports on ICP IM activities are presented as annexes.

  17. Choosing the Right Free IM Providers and Clients for Your Library

    Science.gov (United States)

    Izenstark, Amanda K.

    2009-01-01

    With virtual library services increasing, public services librarians may find themselves with questions such as: What instant messaging services (IM) are available? Which IM service would best suit my patrons' needs? Which IM service best suits my library's technology profile? This column describes the features and functionality of major instant…

  18. World-wide developments in motor vehicle inspection/maintenance (I/M) programs

    Energy Technology Data Exchange (ETDEWEB)

    Klausmeier, R. [Consulting Inc., Austin, TX (United States); Kishan, S. [Radian Corporation, Austin, TX (United States)

    1995-12-31

    Motor vehicles contribute much to urban air pollution. As a result, most governments have enacted emission standards that significantly lower pollutant emission levels from new motor vehicles. For example, vehicles built in the United States emit 95 % fewer pollutants than uncontrolled vehicles when they are new. However, studies indicate that proper maintenance is needed to obtain the full benefit of vehicle emission controls. Furthermore, there is evidence that a significant percentage of the vehicle fleet is not properly maintained. This has led to the creation of motor vehicle Inspection/Maintenance (I/M) Programs. I/M programs inspect vehicles for indications that they are emitting excessive quantities of pollutants. Vehicles that fail the inspection must be repaired in order to comply with program requirements. The first I/M programs were implemented in the United States in the early 1970s. With substantial urging from the federal government, most of the U.S. states with severe air pollution problems have implemented I/M programs. Recently, with the passage of the U.S. Clean Air Act Amendments of 1990, many states have been required to significantly upgrade the performance and coverage of their I/M programs. I/M programs also have been implemented in Europe and recently in Asia. This presentation reviews developments in I/M programs for light-duty gasoline powered vehicles. Developments in I/M programs for diesel powered vehicles are briefly described. (author)

  19. World-wide developments in motor vehicle inspection/maintenance (I/M) programs

    Energy Technology Data Exchange (ETDEWEB)

    Klausmeier, R [Consulting Inc., Austin, TX (United States); Kishan, S [Radian Corporation, Austin, TX (United States)

    1996-12-31

    Motor vehicles contribute much to urban air pollution. As a result, most governments have enacted emission standards that significantly lower pollutant emission levels from new motor vehicles. For example, vehicles built in the United States emit 95 % fewer pollutants than uncontrolled vehicles when they are new. However, studies indicate that proper maintenance is needed to obtain the full benefit of vehicle emission controls. Furthermore, there is evidence that a significant percentage of the vehicle fleet is not properly maintained. This has led to the creation of motor vehicle Inspection/Maintenance (I/M) Programs. I/M programs inspect vehicles for indications that they are emitting excessive quantities of pollutants. Vehicles that fail the inspection must be repaired in order to comply with program requirements. The first I/M programs were implemented in the United States in the early 1970s. With substantial urging from the federal government, most of the U.S. states with severe air pollution problems have implemented I/M programs. Recently, with the passage of the U.S. Clean Air Act Amendments of 1990, many states have been required to significantly upgrade the performance and coverage of their I/M programs. I/M programs also have been implemented in Europe and recently in Asia. This presentation reviews developments in I/M programs for light-duty gasoline powered vehicles. Developments in I/M programs for diesel powered vehicles are briefly described. (author)

  20. Precise outage analysis of mixed RF/unified-FSO DF relaying with HD and 2 IM-DD channel models

    KAUST Repository

    Al-Ebraheemy, Omer Mahmoud S.

    2017-07-20

    This paper derives and analyzes the outage probability of mixed radio frequency (RF)/unified free space optical (FSO) dual-hop decode-and-forward (DF) relaying scheme, where heterodyne detection (HD) and intensity modulation-direct detection (IM-DD) are considered for FSO detection. In doing that, we correctly utilize, for the first time to the best of our knowledge, a precise channel capacity result for the IM-DD channel. Moreover, this is the first time that not only the (IM-DD input-independent) but also the (IM-DD cost-dependent) AWGN channel is considered in such system analysis. This work assumes that the first hop (RF link) follows Naka-gami-m fading, while the second hop (FSO link) follows Málaga (M) turbulence with pointing error. These fading and turbulence models include other ones (such as Rayleigh fading and Gamma-Gamma turbulence) as special cases, so our analysis can be considered as a generalized one from both RF and FSO fading models point of view. Additionally, the system outage probability is investigated asymptotically in high signal-to-noise ratio (SNR) regime, where a new non-reported diversity order and coding gain analysis are shown. Interestingly, we find that in the FSO hop, based on SNR, the HD or IM-DD cost-dependent results in a same diversity order which is twice the one of IM-DD input-independent. However, based on transmitted power all these FSO detectors result in a same diversity order. Furthermore, we offer simulation results which confirm the derived exact and asymptotic expressions.

  1. Precise outage analysis of mixed RF/unified-FSO DF relaying with HD and 2 IM-DD channel models

    KAUST Repository

    Al-Ebraheemy, Omer Mahmoud S.; Salhab, Anas M.; Chaaban, Anas; Zummo, Salam A.; Alouini, Mohamed-Slim

    2017-01-01

    This paper derives and analyzes the outage probability of mixed radio frequency (RF)/unified free space optical (FSO) dual-hop decode-and-forward (DF) relaying scheme, where heterodyne detection (HD) and intensity modulation-direct detection (IM-DD) are considered for FSO detection. In doing that, we correctly utilize, for the first time to the best of our knowledge, a precise channel capacity result for the IM-DD channel. Moreover, this is the first time that not only the (IM-DD input-independent) but also the (IM-DD cost-dependent) AWGN channel is considered in such system analysis. This work assumes that the first hop (RF link) follows Naka-gami-m fading, while the second hop (FSO link) follows Málaga (M) turbulence with pointing error. These fading and turbulence models include other ones (such as Rayleigh fading and Gamma-Gamma turbulence) as special cases, so our analysis can be considered as a generalized one from both RF and FSO fading models point of view. Additionally, the system outage probability is investigated asymptotically in high signal-to-noise ratio (SNR) regime, where a new non-reported diversity order and coding gain analysis are shown. Interestingly, we find that in the FSO hop, based on SNR, the HD or IM-DD cost-dependent results in a same diversity order which is twice the one of IM-DD input-independent. However, based on transmitted power all these FSO detectors result in a same diversity order. Furthermore, we offer simulation results which confirm the derived exact and asymptotic expressions.

  2. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  3. Distributed intelligent urban environment monitoring system

    Science.gov (United States)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  4. Respuestas faciales ante imágenes de advertencia de tabaco

    Directory of Open Access Journals (Sweden)

    M. A. Muñoz

    Full Text Available Resumen En 2003, la Comisión Europea propuso una serie de advertencias visuales para ser incluidas en los embalajes de tabaco, con el objetivo de motivar a los fumadores a dejar de fumar y promover actitudes negativas hacia el tabaco. El objetivo de este estudio fue evaluar el impacto de las advertencias sanitarias mediante autoinformes y medidas psicofisiológicas. Cincuenta sujetos sanos (19-23 años visionaron un conjunto de treinta y seis imágenes de diferente contenido emocional y veinticuatro del banco de imágenes preventivas propuestas por la Comisión Europea. Se registró la actividad eléctrica de los músculos cigomático mayor y corrugador mientras los sujetos visionaban estas imágenes. A continuación, los participantes evaluaban las imágenes en las dimensiones de agradabilidad y activación. Los resultados muestran una mayor actividad eléctrica del musculo corrugador ante la presentación de imágenes desagradables comparadas con advertencias desagradables incluidas en los paquetes de tabaco. Estos resultados sugieren que la campaña preventiva podría beneficiarse de imágenes preventivas más impactantes, promoviendo así la activación del sistema motivacional evitativo/defensivo.

  5. Long-term observations on the influence of groundwater level variations on BTEX concentrations in groundwater; Langzeituntersuchungen zum Einfluss von Grundwasserschwankungen auf die BTEX-Konzentration im Grundwasser

    Energy Technology Data Exchange (ETDEWEB)

    Puettmann, W. [J.W. Goethe-Universitaet Frankfurt a. M., Institut fuer Atmosphaere und Umwelt, AG Umweltanalytik, Frankfurt/Main (Germany); Hettwer, K.; Warrelmann, J. [Universitaet Bremen, Zentrum fuer Umweltforschung und Umwelttechnologie, Bremen (Germany); Gaab, S.

    2007-06-15

    A long-term study on natural attenuation and remediation in soil and groundwater at the former military base Schaeferhof-Sued (Niedersachsen) was performed at a former gasoline filling station. At this locality, a large residual source of benzene, toluene, ethylbenzene, xylenes (BTEX) and additional petroleum hydrocarbons is present in the soil. BTEX-concentrations in the groundwater and their correlation with groundwater level variations were monitored for three years. Within the monitoring period, a very dry summer was recorded, which caused the groundwater level to drop by 1.7 m and the BTEX concentrations to increase from 240 {mu}g/l to 1300 {mu}g/l at the site of contamination. The microbial degradation of BTEX was documented by data on consumption of electron acceptors (oxygen, nitrate or sulphate) and production of reduced products (Fe(II), methane). The degradation is further supported by the detection of metabolites. Therefore, the increasing BTEX concentrations were not a consequence of limited biological degradation. (orig.) [German] Auf dem frueher militaerisch genutzten Gelaende Schaeferhof-Sued (Niedersachsen) wurden im Bereich einer ehemaligen Abfuellstation fuer Kraftstoffe Langzeituntersuchungen zum natuerlichen Schadstoffabbau und -rueckhalt im Boden und Grundwasser durchgefuehrt. Der Standort weist eine hohe Restkontamination der Verbindungen Benzol, Toluol, Ethylbenzol und Xylole (BTEX), sowie Mineraloelkohlenwasserstoffen (MKW) in der ungesaettigten Bodenzone auf. Ueber einen Zeitraum von drei Jahren wurden die BTEX-Konzentrationen im Grundwasser und deren Abhaengigkeit von einer Aenderung des Grundwasserstandes untersucht und eine negative Korrelation der Schadstoffkonzentrationen mit der Hoehe des Grundwasserstandes festgestellt. Im Beobachtungszeitraum lag das sehr trockene Sommerhalbjahr 2003, was im Vergleich zum vorhergehenden Winterhalbjahr eine Absenkung des Grundwasserspiegels um 1,7 m zur Folge hatte und die BTEX-Konzentrationen am

  6. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  7. Online NPP monitoring with neuro-expert system

    International Nuclear Information System (INIS)

    Nabeshima, K.

    2002-01-01

    This study present a hybrid monitoring system for nuclear power plant utilizing neural networks and a rule-based expert system. The whole monitoring system including a data acquisition system and the advisory displays has been tested by an on-line simulator of pressurized water reactor. From the testing results, it was shown that the neural network in the monitoring system successfully modeled the plant dynamics and detected the symptoms of anomalies earlier than the conventional alarm system. The expert system also worked satisfactorily in diagnosing and displaying the system status by using the outputs of neural networks and a priori knowledge base

  8. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  9. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  10. Jung und Alt im Dialog

    Directory of Open Access Journals (Sweden)

    Caroline Baetge

    2012-04-01

    Full Text Available Rezension zu: Kupser, Thomas, und Ida Pöttinger, Hrsg. 2011. Mediale Brücken: Generationen im Dialog durch aktive Medienarbeit. Gesellschaft - Altern - Medien 3. München: kopaed.

  11. Sensorless Control of IM for Limp-Home Mode EV Applications

    DEFF Research Database (Denmark)

    Dehghan-Azad, Ehsan; Gadoue, Shady; Atkinson, David

    2017-01-01

    in electric vehicle (EV) applications. The proposed scheme was experimentally tested on a laboratory dynamometer using a 19-kW IM and a 29-kW controller, which are both currently used in the automotive industry for EV applications. The scheme was also implemented on an electric golf buggy which was equipped......This paper presents a novel speed estimation scheme for induction motors (IMs) based on back electromotive-force model reference adaptive system (back-EMF MRAS). The scheme is employed for the purpose of sensorless fault-Tolerant torque-controlled drives used in a limp-home mode operation...... investigated for vehicle starting from standstill, wide speed range including field weakening region, and hill-starting operations. The proposed scheme is computationally easy to implement, robust against sensitivity to parameters variations, inverter nonlinearity and errors due to digitization in the field...

  12. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  13. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  14. Real-time resource availability signalling in IMS-based networks

    NARCIS (Netherlands)

    Ozcelebi, T.; Radovanovic, I.; Lukkien, J.J.

    2007-01-01

    The emerging converged IP multimedia subsystem (IMS) allows the use of unlicensed, nondedicated and nondeterministic computer access networks for delivering IP multimedia services. To provide end-to-end quality-of-service (QoS) over such networks combined with the IMS core network, for resource

  15. Life Support Systems: Environmental Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...

  16. Acoustic emission leak monitoring system LMS-96

    International Nuclear Information System (INIS)

    Liska, J.; Cvrcek, M.; Mueller, L.

    1997-01-01

    On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)

  17. Adaptively loaded IM/DD optical OFDM based on set-partitioned QAM formats.

    Science.gov (United States)

    Zhao, Jian; Chen, Lian-Kuan

    2017-04-17

    We investigate the constellation design and symbol error rate (SER) of set-partitioned (SP) quadrature amplitude modulation (QAM) formats. Based on the SER analysis, we derive the adaptive bit and power loading algorithm for SP QAM based intensity-modulation direct-detection (IM/DD) orthogonal frequency division multiplexing (OFDM). We experimentally show that the proposed system significantly outperforms the conventional adaptively-loaded IM/DD OFDM and can increase the data rate from 36 Gbit/s to 42 Gbit/s in the presence of severe dispersion-induced spectral nulls after 40-km single-mode fiber. It is also shown that the adaptive algorithm greatly enhances the tolerance to fiber nonlinearity and allows for more power budget.

  18. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  19. Medida Interpessoal de Psicopatia (IM-P: estudo preliminar no contexto brasileiro Interpersonal Measure of Psychopathy (IM-P: preliminary study in the Brazilian context

    Directory of Open Access Journals (Sweden)

    Tárcia Rita Davoglio

    2011-01-01

    Full Text Available INTRODUÇÃO: A observação direta do comportamento interpessoal é um recurso importante na descrição e diagnóstico da personalidade psicopática. A Medida Interpessoal de Psicopatia (Interpersonal Measure of Psychopathy, IM-P é um instrumento psicométrico composto por 21 itens, desenvolvido para ser utilizado em associação com outras escalas de avaliação da psicopatia. Foca-se, especificamente, nos comportamentos interpessoais e aspectos não verbais evidentes na interação do entrevistador com indivíduos que apresentam características psicopáticas. OBJETIVO: Descrever resultados preliminares sobre a investigação de aspectos interpessoais da psicopatia mediante a utilização da IM-P, incluindo as etapas de tradução/adaptação e avaliação de confiabilidade interavaliadores da IM-P, em uma amostra de adolescentes brasileiros. MÉTODO: Trata-se de estudo transversal, descritivo e correlacional realizado com 20 adolescentes masculinos cumprindo medida socioeducativa com privação de liberdade na Região Metropolitana de Porto Alegre (RS. Após os procedimentos de tradução da escala, treinamento dos pesquisadores e teste piloto por meio de uma entrevista semiestruturada, a IM-P foi pontuada por três juízes independentes. RESULTADOS: Os resultados estatísticos, obtidos através do coeficiente de concordância de Kendall, revelaram grau de concordância interavaliadores elevado e satisfatório para os escores totais da IM-P (W = 0,84; p INTRODUCTION: The direct observation of interpersonal behaviors is an important resource in the description and diagnosis of the psychopathic personality. The Interpersonal Measure of Psychopathy (IM-P is a psychometric instrument comprised of 21 items, designed to be applied in association with other instruments that also evaluate psychopaths. It focuses specifically on interpersonal and non-verbal behaviors that become evident during the interaction between the interviewer and individuals

  20. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  1. Big Data solution for CTBT monitoring: CEA-IDC joint global cross correlation project

    Science.gov (United States)

    Bobrov, Dmitry; Bell, Randy; Brachet, Nicolas; Gaillard, Pierre; Kitov, Ivan; Rozhkov, Mikhail

    2014-05-01

    Waveform cross-correlation when applied to historical datasets of seismic records provides dramatic improvements in detection, location, and magnitude estimation of natural and manmade seismic events. With correlation techniques, the amplitude threshold of signal detection can be reduced globally by a factor of 2 to 3 relative to currently standard beamforming and STA/LTA detector. The gain in sensitivity corresponds to a body wave magnitude reduction by 0.3 to 0.4 units and doubles the number of events meeting high quality requirements (e.g. detected by three and more seismic stations of the International Monitoring System (IMS). This gain is crucial for seismic monitoring under the Comprehensive Nuclear-Test-Ban Treaty. The International Data Centre (IDC) dataset includes more than 450,000 seismic events, tens of millions of raw detections and continuous seismic data from the primary IMS stations since 2000. This high-quality dataset is a natural candidate for an extensive cross correlation study and the basis of further enhancements in monitoring capabilities. Without this historical dataset recorded by the permanent IMS Seismic Network any improvements would not be feasible. However, due to the mismatch between the volume of data and the performance of the standard Information Technology infrastructure, it becomes impossible to process all the data within tolerable elapsed time. To tackle this problem known as "BigData", the CEA/DASE is part of the French project "DataScale". One objective is to reanalyze 10 years of waveform data from the IMS network with the cross-correlation technique thanks to a dedicated High Performance Computer (HPC) infrastructure operated by the Centre de Calcul Recherche et Technologie (CCRT) at the CEA of Bruyères-le-Châtel. Within 2 years we are planning to enhance detection and phase association algorithms (also using machine learning and automatic classification) and process about 30 terabytes of data provided by the IDC to

  2. Measurement of anthropogenic radionuclides in the atmosphere with a radionuclide monitoring network for nuclear tests

    International Nuclear Information System (INIS)

    Yonezawa, Chushiro; Yamamoto, Yoichi

    2011-01-01

    A worldwide radionuclide monitoring network for nuclear tests has detected the anthropogenic radioactive materials released in the atmosphere due to the accident of the Fukushima Daiichi Nuclear Power Plant impacted by the Great East Japan Earthquake on March 11, 2011. After four months have passed since the accident occurred, most overseas stations do not detect the radionuclides of Fukushima origin any more. The Takasaki station in Japan, however, is still detecting them every day. This paper describes radionuclide monitoring stations and the network of them as part of the International Monitoring System (IMS) in the Comprehensive Nuclear Test Ban Treaty (CTBT), as well as the measurement results of radionuclide particulates and radioactive isotopes of xenon released from the Fukushima Daiichi Nuclear Power Plant with the monitoring network. (J.P.N.)

  3. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  4. Standard-D hydrogen monitoring system, system design description

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1996-01-01

    During most of the year, it is assumed that the vapor space in the 177 radioactive waste tanks on the Hanford Project site contain a uniform mixture of gases. Several of these waste tanks (currently twenty-five, 6 Double Shell Tanks and 19 Single Shell Tanks) were identified as having the potential for the buildup of gasses to a flammable level. An active ventilation system in the Double Shell Tanks and a passive ventilation system in the Single Shell Tanks provides a method of expelling gasses from the tanks. A gas release from a tank causes a temporary rise in the tank pressure, and a potential for increased concentration of hydrogen gas in the vapor space. The gas is released via the ventilation systems until a uniform gas mixture in the vapor space is once again achieved. The Standard Hydrogen Monitoring System (SHMS) is designed to monitor and quantify the percent hydrogen concentration during these potential gas releases. This document describes the design of the Standard-D Hydrogen Monitoring System, (SHMS-D) and its components as it differs from the original SHMS

  5. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  6. Address Translation Problems in IMS Based Next Generation Networks

    Directory of Open Access Journals (Sweden)

    Balazs Godor

    2006-01-01

    Full Text Available The development of packed based multimedia networks reached a turning point when the ITU-T and the ETSIhave incorporated the IMS to the NGN. With the fast development of mobile communication more and more services andcontent are available. In contrast with fix network telephony both the services and the devices are personalized in the “mobileworld”. Services, known from the Internet - like e-mail, chat, browsing, presence, etc. – are already available via mobiledevices as well. The IMS originally wanted to exploit both the benefits of mobile networks and the fancy services of theInternet. But today it is already more than that. IMS is the core of the next generation telecommunication networks and abasis for fix-mobile convergent services. The fact however that IMS was originally a “mobile” standard, where IPv6 was notoddity generated some problems for the fix networks, where IPv4 is used. In this article I give an overview of these problemsand mention some solutions as well.

  7. FFTF fission gas monitor computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports

  8. Gesundheit und Pflege im Alter

    OpenAIRE

    Pfaff, Martin

    1989-01-01

    Gesundheit und Pflege im Alter : d. Gesundheitsreformgesetz (GRG) ; Möglichkeiten, Grenzen u. weitere Vorschläge / Martin Pfaff ; Klaus Deimer. - In: Expertengespräch "Pflege in der Familie". - Augsburg, 1989. - Getr. Zählung

  9. Components for real-time state monitoring of biological sewage treatment plants; Komponenten zur Echtzeit-Zustandserfassung biologischer Klaeranlagen

    Energy Technology Data Exchange (ETDEWEB)

    Obenaus, F.; Rosenwinkel, K.H. [Hannover Univ. (Germany). Inst. fuer Siedlungswasserwirtschaft und Abfalltechnik

    1999-07-01

    Described is a method for the acquision of comprehensive state monitoring data from a sewage treatment plant's biological stage. The focus is on the measuring point in the effluent from preliminary cleaning. This is the most critical point of the system, its function being safeguarded only if the pollution load induced by the inflow to the biological stage can be exactly monitored. (orig.) [German] Beschrieben wurde eine Methode zum Erhalt umfassender Zustandsinformationen aus der biologischen Reinigungsstufe einer Klaeranlage, wobei der Schwerpunkt der Ausfuehrungen sich der Messstelle im Ablauf der Vorklaerung als kritischstem Punkt des Systems widmete, dessen Funktion nur bei genauer Erfassung der durch den Zulauf zur biologischen Stufe induzierten Belastung gewaehrleistet ist. (orig.)

  10. Digitalisierung im Verteilnetz: Evolution oder Revolution anhand konkreter Beispiele

    Science.gov (United States)

    Krone, Oliver; Bachmann, Maurus

    Durch die Integration der neuen erneuerbaren Energien steht das Stromnetz vor großen Herausforderungen. Das Energiesystem als Gesamtes und die Verteilnetze im Speziellen werden smart. Anhand konkreter Beispiele wird aufgezeigt, wie die Digitalisierung im Elektrizitätsnetz voranschreitet. Diese Entwicklung ist eine Evolution, nicht aber eine Revolution.

  11. Moisture monitoring and control system engineering study

    International Nuclear Information System (INIS)

    Carpenter, K.E.; Fadeff, J.G.

    1995-01-01

    During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria

  12. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  13. THOR Ion Mass Spectrometer instrument - IMS

    Science.gov (United States)

    Retinò, Alessandro; Kucharek, Harald; Saito, Yoshifumi; Fraenz, Markus; Verdeil, Christophe; Leblanc, Frederic; Techer, Jean-Denis; Jeandet, Alexis; Macri, John; Gaidos, John; Granoff, Mark; Yokota, Shoichiro; Fontaine, Dominique; Berthomier, Matthieu; Delcourt, Dominique; Kistler, Lynn; Galvin, Antoniette; Kasahara, Satoshi; Kronberg, Elena

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. Specifically, THOR will study how turbulent fluctuations at kinetic scales heat and accelerate particles in different turbulent environments within the near-Earth space. To achieve this goal, THOR payload is being designed to measure electromagnetic fields and particle distribution functions with unprecedented resolution and accuracy. Here we present the Ion Mass Spectrometer (IMS) instrument that will measure the full three-dimensional distribution functions of near-Earth main ion species (H+, He+, He++ and O+) at high time resolution (~ 150 ms for H+ , ~ 300 ms for He++) with energy resolution down to ~ 10% in the range 10 eV/q to 30 keV/q and angular resolution ~ 10°. Such high time resolution is achieved by mounting multiple sensors around the spacecraft body, in similar fashion to the MMS/FPI instrument. Each sensor combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCP) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification, discrimination and time-to-digital conversion (TDC). IMS is being designed to address many of THOR science requirements, in particular ion heating and acceleration by turbulent fluctuations in foreshock, shock and magnetosheath regions. The IMS instrument is being designed and will be built by an international consortium of scientific institutes with main hardware contributions from France, USA, Japan and Germany.

  14. Ulysses spacecraft control and monitoring system

    Science.gov (United States)

    Hamer, P. A.; Snowden, P. J.

    1991-01-01

    The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

  15. Aggregation und Management von Metadaten im Kontext von Europeana

    Directory of Open Access Journals (Sweden)

    Gerda Koch

    2017-09-01

    Full Text Available Mit dem In-Beziehung-Setzen und Verlinken von Daten im Internet wird der Weg zur Umsetzung des semantischen Webs geebnet. Erst die semantische Verbindung von heterogenen Datenbeständen ermöglicht übergreifende Suchvorgänge und späteres „Machine Learning“. Im Artikel werden die Aktivitäten der Europäischen Digitalen Bibliothek im Bereich des Metadatenmanagements und der semantischen Verlinkung von Daten skizziert. Dabei wird einerseits ein kurzer Überblick zu aktuellen Forschungsschwerpunkten und Umsetzungsstrategien gegeben, und darüber hinaus werden einzelne Projekte und maßgeschneiderte Serviceangebote für naturhistorische Daten, regionale Kultureinrichtungen und Audiosammlungen beschrieben.

  16. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  17. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  18. Bayesian Inference for Signal-Based Seismic Monitoring

    Science.gov (United States)

    Moore, D.

    2015-12-01

    Traditional seismic monitoring systems rely on discrete detections produced by station processing software, discarding significant information present in the original recorded signal. SIG-VISA (Signal-based Vertically Integrated Seismic Analysis) is a system for global seismic monitoring through Bayesian inference on seismic signals. By modeling signals directly, our forward model is able to incorporate a rich representation of the physics underlying the signal generation process, including source mechanisms, wave propagation, and station response. This allows inference in the model to recover the qualitative behavior of recent geophysical methods including waveform matching and double-differencing, all as part of a unified Bayesian monitoring system that simultaneously detects and locates events from a global network of stations. We demonstrate recent progress in scaling up SIG-VISA to efficiently process the data stream of global signals recorded by the International Monitoring System (IMS), including comparisons against existing processing methods that show increased sensitivity from our signal-based model and in particular the ability to locate events (including aftershock sequences that can tax analyst processing) precisely from waveform correlation effects. We also provide a Bayesian analysis of an alleged low-magnitude event near the DPRK test site in May 2010 [1] [2], investigating whether such an event could plausibly be detected through automated processing in a signal-based monitoring system. [1] Zhang, Miao and Wen, Lianxing. "Seismological Evidence for a Low-Yield Nuclear Test on 12 May 2010 in North Korea". Seismological Research Letters, January/February 2015. [2] Richards, Paul. "A Seismic Event in North Korea on 12 May 2010". CTBTO SnT 2015 oral presentation, video at https://video-archive.ctbto.org/index.php/kmc/preview/partner_id/103/uiconf_id/4421629/entry_id/0_ymmtpps0/delivery/http

  19. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  20. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  1. Sexting im Schulumfeld

    Directory of Open Access Journals (Sweden)

    Barbara Buchegger

    2015-03-01

    Full Text Available Wir wollten es einfach wissen. Wie steht es nun mit diesem "Sexting" – also der Übermittlung von Nacktaufnahmen, die Jugendliche untereinander teilen? Stimmt unser Eindruck aus den Workshops in Schulen, dass es bereits ein "übliches Verhalten" der Jugendlichen geworden ist? Saferinternet.at hat im November/Dezember 2014 eine Studie durch das Institut für Jugendkulturforschung rund um das Thema "Sexting" in Auftrag gegeben.

  2. A two-stage extraction procedure for insensitive munition (IM) explosive compounds in soils.

    Science.gov (United States)

    Felt, Deborah; Gurtowski, Luke; Nestler, Catherine C; Johnson, Jared; Larson, Steven

    2016-12-01

    The Department of Defense (DoD) is developing a new category of insensitive munitions (IMs) that are more resistant to detonation or promulgation from external stimuli than traditional munition formulations. The new explosive constituent compounds are 2,4-dinitroanisole (DNAN), nitroguanidine (NQ), and nitrotriazolone (NTO). The production and use of IM formulations may result in interaction of IM component compounds with soil. The chemical properties of these IM compounds present unique challenges for extraction from environmental matrices such as soil. A two-stage extraction procedure was developed and tested using several soil types amended with known concentrations of IM compounds. This procedure incorporates both an acidified phase and an organic phase to account for the chemical properties of the IM compounds. The method detection limits (MDLs) for all IM compounds in all soil types were regulatory risk-based Regional Screening Level (RSL) criteria for soil proposed by the U.S. Army Public Health Center. At defined environmentally relevant concentrations, the average recovery of each IM compound in each soil type was consistent and greater than 85%. The two-stage extraction method decreased the influence of soil composition on IM compound recovery. UV analysis of NTO established an isosbestic point based on varied pH at a detection wavelength of 341 nm. The two-stage soil extraction method is equally effective for traditional munition compounds, a potentially important point when examining soils exposed to both traditional and insensitive munitions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  4. Integrated environmental monitoring and information system

    International Nuclear Information System (INIS)

    Klinda, J.; Lieskovska, Z.

    1998-01-01

    The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included

  5. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  6. Structure health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok

    2003-01-01

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  7. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  8. Structure health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Il Bum; Kim, Chi Yeop; Choi, Man Yong; Lee, Seung Seok [Smart Measurment Group. Korea Resarch Institute of Standards and Science, Saejeon (Korea, Republic of)

    2003-05-15

    Structural health monitoring system should developed to be based on internet and database technology in order to manage efficiently large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconvince.

  9. Structural health monitoring system using internet and database technologies

    International Nuclear Information System (INIS)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok

    2003-01-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.

  10. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  11. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  12. IMPACT OF REALIZED IMS SYSTEM IN PRODUCTION AND DISTRIBUTION OF WATER ON QUALITY OF LIFE

    Directory of Open Access Journals (Sweden)

    Gordana Todorović

    2017-03-01

    Full Text Available In this paper from the assessments: the satisfaction of the citizens with the services PUC "Waterworks and Sewerage" and the total time interruption in water supply, appreciating their importance, we carried out the assessment of the implemented IMS PUC "Waterworks and Sewerage" in Kragujevac.

  13. Modification of GNPS environment radiation monitoring network system

    International Nuclear Information System (INIS)

    Jiang Lili; Cao Chunsheng

    1999-01-01

    GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition

  14. IMS Intra- and Inter Domain End-to-End Resilience Analysis

    DEFF Research Database (Denmark)

    Kamyod, Chayapol; Nielsen, Rasmus Hjorth; Prasad, Neeli R.

    2013-01-01

    This paper evaluated resilience of the reference IMS based network topology in operation through the keys reliability parameters via OPNET. The reliability behaviors of communication within similar and across registered home IMS domains were simulated and compared. Besides, the reliability effects...

  15. EFEKTIVITAS MEDIA PEMBELAJARAN IM3 DITINJAU DARI MOTIVASI BELAJAR

    Directory of Open Access Journals (Sweden)

    J. Handhika

    2012-10-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui perbedaan penggunaan media pembelajaran IM3 berbasis flash dan media MS. Power Point terhadap prestasi belajar IPA-Fisika. Hasil penelitian  menunjukkan bahwa siswa yang diajar menggunakan media IM3 berbasis flash memberikan rata-rata prestasi lebih baik dibandingkan dengan siswa yang diajar menggunakan power point. Siswa dengan motivasi belajar tinggi menghasilkan rata-rata prestasi lebih baik daripada siswa dengan motivasi belajar rendah, serta terdapat interaksi motivasi belajar dengan media pembelajaran terhadap prestasi belajar IPA-Fisika.   This study aims to determine differences in the use of flash-based IM3 learning media and MS media. Power Point to IPA-Physics learning achievement. Results showed that students who were taught using flash-based media IM3 gives an average performance better than students who were taught using the power point. Students with high motivation to learn the average yield better performance than students with low learning motivation, and there is interaction with the medium of learning motivation toward science learning achievement-Physics.

  16. Ausländische Direktinvestitionen und Technologietransfer im angolanischen Energiesektor

    Directory of Open Access Journals (Sweden)

    2016-04-01

    Full Text Available Dem Zusammenhang von ausländischen Direktinvestionen (Foreign Direct Investment, FDI und Technologietransfer wird sowohl in der Forschung als auch in der politischen Analyse große Bedeutung zugeschrieben. Zahlreiche Veröffentlichungen belegen, dass FDI den Transfer von und/oder den Zugang zu Technologien erleichtert. Allerdings gibt es zu wenige empirische Studien, die diesen Zusammenhang in Bezug auf die Wirtschaft afrikanischer Staaten untersuchen. Der Autor will diese Lücke zu einem kleinen Teil schließen, indem er die Bedeutung des Technologietransfers durch den Zufluss von FDI im Energiesektor Angolas ermittelt. Seine Analyse basiert auf qualitativer Forschung in Angola im Jahr 2014. Er zeigt auf, dass sich die Erzeugung von Energie(trägern und die Verteilungsinfrastruktur - maschinelle Ausrüstung und Qualifizierung - durch den Zufluss von FDI erheblich entwickeln konnte. Allerdings gebe es keinen Beleg dafür, dass dieser Zufluss die endogenen wissenschaftlichen und technologischen Forschungspotenziale im angolanischen Energiesektor gefördert hat. Der Autor empfiehlt politische Maßnahmen zur Förderung dieser Fähigkeiten, insbesondere im Bereich der Produktion.

  17. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  18. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  19. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  20. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    Science.gov (United States)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  1. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    International Nuclear Information System (INIS)

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  2. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  3. ifo Konjunkturprognose 2015/2016: Deutsche Wirtschaft im Aufschwung

    OpenAIRE

    Wollmershäuser, Timo; Nierhaus, Wolfgang; Berg, Tim Oliver; Breuer, Christian; Garnitz, Johanna; Grimme, Christian; Henzel, Steffen; Hristov, Atanas; Hristov, Nikolay; Meister, Wolfgang; Schröter, Felix; Steiner, Andreas; Wieland, Elisabeth; Wohlrabe, Klaus; Wolf, Anna

    2015-01-01

    Die deutsche Wirtschaft befindet sich derzeit in einem kräftigen Aufschwung. Das reale Bruttoinlandsprodukt wird in diesem Jahr voraussichtlich um 1,9% expandieren und im kommenden Jahr um 1,8%. Der private Konsum bleibt die Stütze des Aufschwungs, da die Einkommensperspektiven der privaten Haushalte aufgrund der sich weiter verbessernden Arbeitsmarktlage gut sind. Allerdings entfallen allmählich die Kaufkraftgewinne durch den Ölpreisrückgang, so dass sich die Konsumdynamik im Prognosezeitrau...

  4. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  5. Hybrid Wireless Hull Monitoring System for Naval Combat Vessels

    Science.gov (United States)

    2010-03-01

    Payload Data Acquisition System (SPDAS) is designed by the Technology Management Group, Inc. ( TMG ). In its design, the monitoring system is intended...monitoring system custom designed by TMG for the U.S. Navy. The Scientific Payload Data Acquisition System (SPDAS) is a wired hull monitoring system

  6. Effects of Cougar Predation and Nutrition on Mule Deer Population Declines in the IM Province of the Columbia Basin, Annual Report 2002-2003.

    Energy Technology Data Exchange (ETDEWEB)

    Wielgus, Robert; Shipley, Lisa; Myers, Woodrow

    2003-09-01

    Construction of the Grand Coulee and Chief Joseph dams has resulted in inundation and loss of 29,125 total habitat units for mule deer and irrigation agriculture in many parts the Intermountain Province (IM) of the Columbia Basin. Mule deer in the Shrub-Steppe are ranked high priority target species for mitigation and management and are declining in most portions of the sub basins of the IM. Reasons for the decline are unknown but believed to be related to habitat changes resulting from dams and irrigation agriculture. White-tailed deer are believed to be increasing throughout the basin because of habitat changes brought about by the dams and irrigation agriculture. Recent research (1997-2000) in the NE IM and adjacent Canadian portions of the Columbia Basin (conducted by this author and funded by the Columbia Basin Fish & Wildlife Compensation Program B.C.), suggest that the increasing white-tailed deer populations (because of dams and irrigation agriculture) are resulting in increased predation by cougars on mule deer (apparent competition or alternate prey hypothesis). The apparent competition hypothesis predicts that as alternate prey (white-tailed deer) densities increase, so do densities of predators, resulting in increased incidental predation on sympatric native prey (mule deer). Apparent competition can result in population declines and even extirpation of native prey in some cases. Such a phenomenon may account for declines of mule deer in the IM and throughout arid and semi-arid West where irrigation agriculture is practiced. We will test the apparent competition hypothesis by conducting a controlled, replicated 'press' experiment in at least 2 treatment and 2 control areas of the IM sub basins by reducing densities of white-tailed deer and observing any changes in cougar predation on mule deer. Deer densities will be monitored by WADFW personnel using annual aerial surveys and/or other trend indices. Predation rates and population growth rates

  7. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  8. CRISPR/Cas9-mediated targeting of the Rosa26 locus produces Cre reporter rat strains for monitoring Cre-loxP-mediated lineage tracing.

    Science.gov (United States)

    Ma, Yuanwu; Yu, Lei; Pan, Shuo; Gao, Shan; Chen, Wei; Zhang, Xu; Dong, Wei; Li, Jing; Zhou, Rui; Huang, Lan; Han, Yunlin; Bai, Lin; Zhang, Li; Zhang, Lianfeng

    2017-10-01

    The rat is an important laboratory animal for physiological, toxicological and pharmacological studies. Clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated 9 (Cas9) is a simple and efficient tool to generate precise genetic modifications in rats, which will promote the accumulation of genetic resources and enable more precise studies of gene function. To monitor Cre-loxP-mediated excision in vivo, we generated a Cre reporter rat strain (Rosa26-imCherry) by knockin of a Cre reporter cassette at the Rosa26 locus using CRISPR/Cas9. Rosa26-imCherry rats exhibited inducible expression of the mCherry cassette (imCherry) using the Cre-loxP system, whereas normal rats exhibited ubiquitous expression of eGFP but not mCherry in the whole body. Injection of adeno-associated virus serotype 9-Cre into the hippocampus and skeletal muscle resulted in mCherry expression in virus-infected cells. Cre-loxP-mediated mCherry expression was then evaluated by crossing Rosa26-imCherry rats with transgenic rats ubiquitously expressing CAG-Cre, heart-specific α-MHC-Cre transgenic rats and liver-specific Alb-Cre knockin rats. Finally, using the established system the expression pattern of Cre driven by two endogenous gene promoters (Wfs1-Cre knockin rat, FabP2-Cre knockin rat) was traced. In summary, we demonstrated excision of the loxP-flanked allele in Rosa26-imCherry rats via activation of mCherry expression in the presence of Cre recombinase. This newly established Rosa26-imCherry rat strain represents a useful tool to facilitate Cre-expression pattern determination and tracing experiments. © 2017 Federation of European Biochemical Societies.

  9. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  10. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  11. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  12. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  13. Measuring cognitive change with ImPACT: the aggregate baseline approach.

    Science.gov (United States)

    Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul

    2017-11-01

    The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.

  14. ImSET: Impact of Sector Energy Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Roop, Joseph M.; Scott, Michael J.; Schultz, Robert W.

    2005-07-19

    This version of the Impact of Sector Energy Technologies (ImSET) model represents the ''next generation'' of the previously developed Visual Basic model (ImBUILD 2.0) that was developed in 2003 to estimate the macroeconomic impacts of energy-efficient technology in buildings. More specifically, a special-purpose version of the 1997 benchmark national Input-Output (I-O) model was designed specifically to estimate the national employment and income effects of the deployment of Office of Energy Efficiency and Renewable Energy (EERE) -developed energy-saving technologies. In comparison with the previous versions of the model, this version allows for more complete and automated analysis of the essential features of energy efficiency investments in buildings, industry, transportation, and the electric power sectors. This version also incorporates improvements in the treatment of operations and maintenance costs, and improves the treatment of financing of investment options. ImSET is also easier to use than extant macroeconomic simulation models and incorporates information developed by each of the EERE offices as part of the requirements of the Government Performance and Results Act.

  15. Analysis of photovoltaic systems. Leadership/cooperation in Task II of the IEA Implementing Agreements Photovoltaic Power Systems, database operation; Analyse des Betriebsverhaltens von Photovoltaiksystemen. Leitung/Mitarbeit im Task II des IEA Implementing Agreements Photovoltaic Power Systems, Betrieb der Datenbank. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schreitmueller, K.; Niemann, M.; Decker, B.; Jahn, U.; Meyer, H.

    2000-02-01

    In order to state on the operational performance of PV systems and to develop guidelines for sizing and design optimisation, this project has been initiated in 1995 with the general objective to develop a database on PV power systems to provide PV experts and other target groups with suitable information on the operation of PV systems and subsystems. At present the database contains more than 260 systems of different types (grid connected, stand-alone, hybrid) adapted to various applications (power supply, domestic uses, rural electrification, professional applications). Detailed system characteristics of selected PV plants as well as monitored data are stored in the database. The data are made available to the user through internal graphical displays and reports or by exporting the data into a standard spread sheet programme. This tool can also be used to check the operational behaviour of existing PV plants and to get a report on its performance expressed in standard quantities allowing any kind of crossed comparison between systems. The implemented PV systems are located world wide and have been operated under different climatic conditions. A collection of such an amount of various operational data can be considered as a unique tool for PV system performance analysis. The results are very different depending on the type of systems. The analysis has been carried out using quantities such as reference and final yields, system and capture losses and performance ratio linked to the system availability. In the case of stand-alone systems, different factors such as the matching factor (performance ratio x solar fraction) and the usage factor (energy supplied by the PV array/potential PV energy) have been introduced to better quantify the system behaviour in a technical viewpoint and if necessary to define a ranking procedure. This report summarises the most important features and capabilities of the database and related toolbox. The most relevant results drawn from

  16. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  17. Fiber optical measurement systems and their possible uses in final storage; Faseroptische Mess-Systeme und ihre Einsatzmoeglichkeiten im Bereich der Endlagerung

    Energy Technology Data Exchange (ETDEWEB)

    Jobmann, Michael [DBE Technology GmbH, Peine (Germany)

    2002-06-01

    In the operating phase of a repository, surveillance of the underground cavities is indispensable for operational safety. In addition, the data collected in this way can provide reliable information for the long-term safety analysis conducted before commissioning. Fiber optical in-situ surveillance systems represent reliable tools, requiring little maintenance, which can be used to check and monitor underground environmental parameters of a repository over many decades. Since 1995, DBE TECHNOLOGY has been involved in the development and advanced development, respectively, of fiber optical measurement systems with financial assistance by the German Federal Ministry for Education and Research (BMBF). Optical fiber technology offers clear advantages which resulted in the rapid acceptance of this technology in plant surveillance and process control, especially under difficult operating conditions. Optical fibers not only are more resistant to chemical corrosion and high temperature; their ideal electromagnetic compatibility, large bandwidths, and high transmission speeds ensure high reliability and excellent performance characteristics. Moreover, the very good networking capabilities allow large sensor systems to be run effectively, thus obviating the need for sophisticated digitization. The transmitter in this case is reduced to very basic elements - and optical fiber. This makes for low-cost, low-maintenance, reliable solutions. Optical fibers thus are the preferred solution in sensor technology and signal transmission for long-term surveillance jobs, including repositories. (orig.) [German] Waehrend der Betriebsphase eines Endlagers sind aus Gruenden der Betriebssicherheit Ueberwachungsmassnahmen in den untertaegigen Hohlraeumen unumgaenglich. Zudem sind die Daten geeignet, belastbare Angaben fuer die im Vorfeld durchgefuehrte Langzeit-Sicherheitsanalyse zu liefern. Faseroptische in-situ Ueberwachungssysteme stellen dabei ein verlaessliches und wartungsarmes

  18. Radiological diagnostics of malignant tumors of the musculoskeletal system in childhood and adolescence; Radiologische Diagnostik maligner Tumoren des Muskuloskelettalsystems im Kindes- und Adoleszentenalter

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, S.F.; Krestan, C.R. [Medizinische Universitaet Wien, Klinische Abteilung fuer Neuroradiologie und muskuloskelettale Radiologie, Wien (Austria); Hojreh, A.; Hoermann, M. [Medizinische Universitaet Wien, Klinische Abteilung fuer Allgemeine Radiologie und Kinderradiologie, Wien (Austria)

    2008-10-15

    Rhabdomyosarcoma, osteosarcoma and Ewing's sarcoma are the most common malignant tumors of the musculoskeletal system in childhood and adolescence representing about 10% of newly diagnosed cancers in children and adolescents. In the last two decades the prognosis of patients with such malignancies improved significantly. On the one hand because of the advances in chemotherapy and orthopedic surgery, on the other hand also because of the innovations in radiological diagnostics. The precise pre-therapeutical staging of tumors of the musculoskeletal system provides important prognostic information and has impact on the entire therapy management. During respectively after therapy, imaging is extremely important in the follow-up and in diagnosing a possible recurrent disease. Modern imaging diagnostics of musculoskeletal tumors basically consist of conventional X-ray, of computed tomography (CT) and magnetic resonance imaging (MRI), and of modalities of nuclear medicine such as szintigraphy, positron emission tomography (PET) and PET CT. (orig.) [German] Das Rhabdomyosarkom, das Osteosarkom und das Ewing-Sarkom sind die am haeufigsten auftretenden malignen Tumoren des Muskuloskelettalsystems im Kindes- und Adoleszentenalter. Diese Erkrankungen repraesentieren etwa 10% der bei Kindern und Jugendlichen neu diagnostizierten Tumoren. In den letzten beiden Jahrzehnten hat sich insgesamt die Prognose der Patienten mit solchen Malignomen deutlich gebessert. Einerseits aufgrund der Fortschritte in der Chemotherapie und orthopaedischen Tumorchirurgie, andererseits nicht zuletzt aufgrund der zahlreichen Innovationen der radiologischen Diagnostik. Das praezise praetherapeutische Staging von Tumoren des Muskuloskelettalsystems liefert wichtige prognostische Informationen und beeinflusst das gesamte Therapiemanagement. Waehrend bzw. nach erfolgter Therapie ist die Bildgebung ganz entscheidend im Follow-up und bei der Diagnostik einer moeglichen Rezidiverkrankung. Die moderne

  19. Solvation of UCl{sub 6}{sup 2-} anionic complex by MeBu{sub 3}N{sup +}, BuMe{sub 2}Im{sup +} and BuMeIm{sup +} cations

    Energy Technology Data Exchange (ETDEWEB)

    Bosse, Emilie; Den Auwer, Christophe; Berthon, Claude; Guilbaud, Philippe; Moisy, Philippe [CEA Marcoule, DRCP/SCPS, BP 17171, 30207 Bagnols sur Ceze Cedex (France); Grigoriev, Mikhail S. [A.N. Frumkin Institute of Physical Chemistry and Electrochemistry, RAS, Leninskii Prosp. 31, 119991 Moscow (Russian Federation); Nikitenko, Serguei [CNAB, UMR 5084, CNRS - Universite de Bordeaux 1, BP 120 Le Haut Vigneau, 33175 Gradignan Cedex (France); Le Naour, Claire; Cannes, Celine [IPN, UMR 8608, CNRS, Universite Paris-Sud, 91406 Orsay (France)

    2008-07-01

    The complexes [MeBu{sub 3}N]{sub 2}[UCl{sub 6}] and [BuMe{sub 2}Im]{sub 2}[UCl{sub 6}] were characterized in the solid state and in solution of [MeBu{sub 3}N][Tf{sub 2}N], [BuMe{sub 2}Im][Tf{sub 2}N] and [BuMeIm][Tf{sub 2}N] room temperature ionic liquids using single-crystal XRD, EXAFS, electrochemistry, UV-visible absorption spectroscopy and NMR. In the solid and in solution, the existence of hydrogen bonding between the anionic UCl{sub 6}{sup 2-} complex and the ionic liquid cations were revealed by these techniques. The MeBu{sub 3}N{sup +} cation interacts with UCl{sub 6}{sup 2-} via the protons on the alpha carbon atoms of nitrogen. The protons of the imidazolium ring account for the interaction between the BuMe{sub 2}Im+ cation and the UCl{sub 6}{sup 2-} anion. For the BuMeIm{sup +} cation the major interaction was confirmed between the most acidic proton on C(2) and UCl{sub 6}{sup 2-}. The experimental results also show that the intensity of the interaction between the UCl{sub 6}{sup 2-} anion and the cation varies with the ionic liquid cation in the following order: MeBu{sub 3}N{sup +} {approx} BuMe{sub 2}Im{sup +} << BuMeIm{sup +}. (authors)

  20. Monitoring support system for nuclear power plant

    International Nuclear Information System (INIS)

    Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki

    1996-01-01

    The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)

  1. Beacon-Colss core monitoring system application and benefits

    International Nuclear Information System (INIS)

    Boyd, W.A.; Yoon, T.Y.

    2005-01-01

    Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)

  2. Applications for cyber security - System and application monitoring

    International Nuclear Information System (INIS)

    Marron, J. E.

    2006-01-01

    Standard network security measures are adequate for defense against external attacks. However, many experts agree that the greater threat is from internal sources. Insiders with malicious intentions can change controller instructions, change alarm thresholds, and issue commands to equipment which can damage equipment and compromise control system integrity. In addition to strict physical security the state of the system must be continually monitored. System and application monitoring goes beyond the capabilities of network security appliances. It will include active processes, operating system services, files, network adapters and IP addresses. The generation of alarms is a crucial feature of system and application monitoring. The alarms should be integrated to avoid the burden on operators of checking multiple locations for security violations. Tools for system and application monitoring include commercial software, free software, and ad-hoc tools that can be easily created. System and application monitoring is part of a 'defense-in-depth' approach to a control network security plan. Layered security measures prevent an individual security measure failure from being exploited into a successful security breach. Alarming of individual failures is essential for rapid isolation and correction of single failures. System and application monitoring is the innermost layer of this defense strategy. (authors)

  3. Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji

    1981-07-01

    In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)

  4. Analysis of the flow in the exit of propfans; Analyse der raeumlichen Stroemung im Austritt eines Propfans

    Energy Technology Data Exchange (ETDEWEB)

    Maass, M [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Koeln (Germany). Inst. fuer Antriebstechnik

    1997-12-31

    In this work the first rotor of a counterrotating shrouded propfan has been investigated to enable an overview of the complex rotor exit flow, basing on unsteady measurements. For this purpose the accuracy of the high speed probe technique has been improved. In combination with the 3D-Laser-2-Fokus system measurements were carried out in order to show the turbulent behaviour of the rotor exit flow. Though the turbulence models are presently not sufficiently developed, comparisons with results of numerical flow simulations support to interpret some wake details. A further focal point of this work is to determine the local losses for quantifying the isentropic efficiency and the pressure loss distribution. These investigations on the compressor`s exit flow can be used as a base for code validation and as design data for the next stage. (orig.). 95 figs., 2 tabs., 60 refs. [Deutsch] In dieser Arbeit wurde der erste Rotor eines gegenlaeufigen ummantelten Propfans experimentell untersucht. Damit soll ein Einblick in die komplexe Verdichtungsaustrittsstroemung ermoeglicht werden, basierend auf instationaeren Messungen im Nachlaufbereich. Hierzu wurde die Messgenauigkeit der instationaeren Totaldruckmesstechnik verbessert und zusammen mit dem 3D-Laser-2-Fokus-System im Verdichteraustritt angewendet. Mit diesen Messungen wird das turbulente Verhalten der Nachlaufstroemung aufgezeigt. Vergleiche mit Ergebnissen aus Rechnungen helfen trotz der derzeit noch nicht weit genug entwickelten Turbulenzmodelle, Stroemungsphaenomene im Nachlauf zu erklaeren. Ein weiterer Schwerpunkt der Arbeit liegt in der Bestimmung der lokalen Verlustleistung, um den lokalen Wirkungsgrad und damit die lokalen Verluste im Verdichteraustritt quantifizieren zu koennen. Diese Untersuchungen im Verdichteraustritt koennen als Datenbasis fuer Codevalidierung dienen und fuer die Auslegung als Eintrittsgroessen eines nachgeschalteten zweiten Rotors verwendet werden. (orig.)

  5. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  6. A radiation monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  7. Monitoring Distributed Real-Time Systems: A Survey and Future Directions

    Science.gov (United States)

    Goodloe, Alwyn E.; Pike, Lee

    2010-01-01

    Runtime monitors have been proposed as a means to increase the reliability of safety-critical systems. In particular, this report addresses runtime monitors for distributed hard real-time systems. This class of systems has had little attention from the monitoring community. The need for monitors is shown by discussing examples of avionic systems failure. We survey related work in the field of runtime monitoring. Several potential monitoring architectures for distributed real-time systems are presented along with a discussion of how they might be used to monitor properties of interest.

  8. Automated Cryocooler Monitor and Control System Software

    Science.gov (United States)

    Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad

    2011-01-01

    This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

  9. Handover Based IMS Registration Scheme for Next Generation Mobile Networks

    Directory of Open Access Journals (Sweden)

    Shireen Tahira

    2017-01-01

    Full Text Available Next generation mobile networks aim to provide faster speed and more capacity along with energy efficiency to support video streaming and massive data sharing in social and communication networks. In these networks, user equipment has to register with IP Multimedia Subsystem (IMS which promises quality of service to the mobile users that frequently move across different access networks. After each handover caused due to mobility, IMS provides IPSec Security Association establishment and authentication phases. The main issue is that unnecessary reregistration after every handover results in latency and communication overhead. To tackle these issues, this paper presents a lightweight Fast IMS Mobility (FIM registration scheme that avoids unnecessary conventional registration phases such as security associations, authentication, and authorization. FIM maintains a flag to avoid deregistration and sends a subsequent message to provide necessary parameters to IMS servers after mobility. It also handles the change of IP address for user equipment and transferring the security associations from old to new servers. We have validated the performance of FIM by developing a testbed consisting of IMS servers and user equipment. The experimental results demonstrate the performance supremacy of FIM. It reduces media disruption time, number of messages, and packet loss up to 67%, 100%, and 61%, respectively, as compared to preliminaries.

  10. Regelungen im Verkehr mit Lebensmitteln und Bedarfsgegenständen in Deutschland

    Science.gov (United States)

    Thomas, Gundula; Freund, Astrid; Gründig, Friedrich

    Im Zuge der Globalisierung von Produktion und Handel ändert sich auch der Charakter der Vorschriften im Lebensmittelrecht. Zunehmend treten internationale Rechtsbestimmungen, Abkommen, Standards und andere Normen an die Stelle nationaler Regelungen.

  11. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  12. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  13. Propose Reactor Control and Monitoring System for RTP

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha

    2011-01-01

    Reactor control and monitoring system is a one of the important features used in reactor. The control and monitoring must come together to provide safety, excellent performance and reliable in nuclear reactor technology application. Objectives of this technical paper are to design and propose reactor control system and reactor monitoring system in Research Reactor (RTP) for Reactor Upgrading Project. (author)

  14. Water monitoring and its information management system in China; Chugoku ni okeru suishitsu monitoring to joho kanri system

    Energy Technology Data Exchange (ETDEWEB)

    Quan, H.

    1996-01-10

    This paper summarizes the water monitoring system (WMS) in China applied mainly to surface water and operated within the competence of the Environmental Protection Agency. The WMS consists of a national water monitoring network and a water information system that monitors surface water periodically. The WMS comprises water monitoring stations classified from class 1 to class 4, which are located in 2,222 locations. Stations from class 1 to class 3 are operated by using computers, but class 4 stations are still incapable to use floppy disks to perform information transmission. When an information management system is completed at the China-Japan Friendship Environmental Protection Center being constructed by gratis assistance from the Japanese Government, transmission of water quality data will become possible by means of the cable line system in addition to the table system and the floppy system. The water quality data are published to general people in the forms of Chinese gazette for the environmental conditions, the environment yearbook, and the reports on environmental quality. However, the more important is to publish more publications to make people aware of the actual state of water pollution and have them cooperate in environment preservation. 4 refs., 1 fig.

  15. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  16. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  17. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  18. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  19. The implementation of the Plan Esperanza and response to the imPACT Review.

    Science.gov (United States)

    Vidaurre, Tatiana; Santos, Carlos; Gómez, Henry; Sarria, Gustavo; Amorin, Edgar; López, Marga; Regalado, Roxana; Manrique, Javier; Tarco, Duniska; Ayestas, Carlos; Calderón, Mónica; Mas, Luis; Neciosup, Silvia; Salazar, Miriam; Chávez, Juan Carlos; Ubillus, Milward; Limache, Abel; Ubillus, José Carlos; Navarro, Jeannie; Sarwal, Kavita; Sutcliffe, Simon; Gutiérrez-Aguado, Alfonso; Silva, Marianela; Mena, Amalia; Guillén, María Eugenia; Castañeda, Carlos; Abugattas, Julio

    2017-10-01

    Following the implementation of the National Cancer Prevention and Control Results-based Budget Programme (PpR Cancer-024) in 2011, the Peruvian Government approved the Plan Esperanza-a population-based national cancer control plan-in 2012. Legislation that ensured full government-supported funding for people who were otherwise unable to access or afford care and treatment accompanied the Plan. In 2013, the Ministry of Health requested an integrated mission of the Programme of Action for Cancer Therapy (imPACT) report to strengthen cancer control in Peru. The imPACT Review, which was executed in 2014, assessed Peru's achievements in cancer control, and areas for improvement, including cancer control planning, further development of population-based cancer registration, increased prevention, early diagnosis, treatment and palliative care, and the engagement and participation of civil society in the health-care system. This Series paper gives a brief history of the development of the Plan Esperanza, describes the innovative funding model that supports it, and summarises how funds are disseminated on the basis of disease, geography, and demographics. An overview of the imPACT Review, and the government's response in the context of the Plan Esperanza, is provided. The development and execution of the Plan Esperanza and the execution of and response to the imPACT Review demonstrates the Peruvian Government's commitment to fighting cancer across the country, including in remote and urban areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Thermal Degradation Study of IM7/DMBZ-15 High Temperature Composite by TGA/FTIR

    National Research Council Canada - National Science Library

    Nadler, Melvin

    2003-01-01

    (U) High temperature graphite composites such as IM7/8552 epoxy, IM7/5250 BMI, and IM7/DMBZ-15 polyimide show blistering and/or "catastrophic" delamination when rapidly heated to temperatures above...

  1. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  2. [Variation im heutigen Deutsch...] / Laura Tidrike

    Index Scriptorium Estoniae

    Tidrike, Laura

    2008-01-01

    Arvustus: Variation im heutigen Deutsch : Perspektiven für den Sprachunterricht / hrsg. v. Eva Neuland. Frankfurt am Main : Lang, 2006. (Sprache - Kommunikation - Kultur. Soziolinguistische Beiträge ; Vol. 4)

  3. Estudios por imágenes en reumatismo

    Directory of Open Access Journals (Sweden)

    Muñoz Ch. Sara, Dra.

    2012-07-01

    Los grandes avances tecnológicos de la última década han mejorado la calidad y cantidad de información que las distintas técnicas aportan, especialmente la RM; esto hace vislumbrar un cambio significativo en el diagnóstico por imágenes, ya que en el futuro no solo estará basado en los cambios morfológicos en órganos y tejidos; las imágenes obtenidas aportarán información bioquímica, molecular y fisiológica de los procesos patológicos facilitando su diagnóstico aun más precoz.

  4. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  5. A new type gamma-ray spectrum monitoring system

    CERN Document Server

    Cheng Bo; Zhou Jian Bin; Zhang Zhi Ming; Tong Yun Fu

    2002-01-01

    This new radiation monitoring system can be used to monitor the radiation of building materials and the radiation of atmosphere, to explore and evaluate rock for building in the field, and this system can be used to monitor the gamma irradiation near the nuclear establishments in the average situation and in the serious situation of the radiation incident have happened. The control core of this monitoring system is SCM-AT89C52, and gamma-ray sensing head consists of scintillator phi 50 mm x 50 mm NaI(Tl) and PMT GDB44. This system can be used to measure the whole gamma-ray spectrum of 256 channels

  6. Studies of Polar Current Systems Using the IMS Scandinavian Magnetometer Array

    Science.gov (United States)

    Untiedt, J.; Baumjohann, W.

    1993-09-01

    As a contribution to the International Magnetospheric Study (IMS, 1976 1979) a two-dimensional array of 42 temporary magnetometer stations was run in Scandinavia, supplementary to the permanent observatories and concentrated in the northern part of the region. This effort aimed at the time-dependent (periods above about 100 s) determination of the two-dimensional structure of substorm-related magnetic fields at the Earth's surface with highest reasonable spatial resolution (about 100 km, corresponding to the height of the ionosphere) near the footpoints of field-aligned electric currents that couple the disturbed magnetosphere to the ionosphere at auroral latitudes. It has been of particular advantage for cooperative studies that not only simultaneous data were available from all-sky cameras, riometers, balloons, rockets, and satellites, but also from the STARE radar facility yielding colocated two-dimensional ionospheric electric field distributions. In many cases it therefore was possible to infer the three-dimensional regional structure of substorm-related ionospheric current systems. The first part of this review outlines the basic relationships and methods that have been used or have been developed for such studies. The second short part presents typical equivalent current patterns observed by the magnetometer array in the course of substorms. Finally we review main results of studies that have been based on the magnetometer array observations and on additional data, omitting studies on geomagnetic pulsations. These studies contributed to a clarification of the nature of auroral electrojets including the Harang discontinuity and of ionospheric current systems related to auroral features such as the break-up at midnight, the westward traveling surge, eastward drifting omega bands, and spirals.

  7. Smart health monitoring systems: an overview of design and modeling.

    Science.gov (United States)

    Baig, Mirza Mansoor; Gholamhosseini, Hamid

    2013-04-01

    Health monitoring systems have rapidly evolved during the past two decades and have the potential to change the way health care is currently delivered. Although smart health monitoring systems automate patient monitoring tasks and, thereby improve the patient workflow management, their efficiency in clinical settings is still debatable. This paper presents a review of smart health monitoring systems and an overview of their design and modeling. Furthermore, a critical analysis of the efficiency, clinical acceptability, strategies and recommendations on improving current health monitoring systems will be presented. The main aim is to review current state of the art monitoring systems and to perform extensive and an in-depth analysis of the findings in the area of smart health monitoring systems. In order to achieve this, over fifty different monitoring systems have been selected, categorized, classified and compared. Finally, major advances in the system design level have been discussed, current issues facing health care providers, as well as the potential challenges to health monitoring field will be identified and compared to other similar systems.

  8. Using IMS VDEX in Agrega

    Directory of Open Access Journals (Sweden)

    Jose Manuel Canabal

    2009-03-01

    Full Text Available An essential element in a learning object repository is the meta-information associated with the resources housed by the repository, as this is what enables the objects to be retrieved. In many cases, the meta-information which is described consists of the classification of a resource in relation to a taxonomy or thesaurus. Agrega is a network of learning object repositories in which an LOM profile, called LOM-ES, has been used to label the objects. Part of the meta-information described corresponds to the classification of the object with respect to a group of taxonomies and a thesaurus, which have had to be described using the ims vdex standard to enable them to be managed from the federation nodes. This article describes the way in which ims vdex has been used in order to create this description and how these metadata instances are managed.

  9. Combined heat and power generation - a problem of reimbursement? CHP systems still on the march; BHKW - nur eine Frage der angemessenen Verguetung? Kraft-Waerme-Kopplung weiter im Aufwind

    Energy Technology Data Exchange (ETDEWEB)

    Jost, H.

    1996-04-15

    Systems for combined heat and power generation were a widely discussed issue in 1995. On the one hand, an ecological assessment was made by a study of the Eduard-Pestel-Institut fuer Systemforschung, Hanover. On the other hand, the problem of reimbursement for electricity supplied to the public grid is still unsolved. (orig.) [Deutsch] Anlagen zur gekoppelten Erzeugung von Strom (Kraft) und Waerme (KWK) waren im Jahr 1995 Gegenstand einer intensiven Diskussion. Zum einen hat eine Diskussion zur oekologischen Bewertung von KWK-Anlagen stattgefunden, die im wesentlichen von einer Studie des Eduard-Pestel-Instituts fuer Systemforschung in Hannover angestossen wurde. Zum anderen sind die Verguetungen fuer KWK-Strom in das oeffentliche Netz nach wie vor umstritten. (orig.)

  10. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  11. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  12. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  13. Ion mobility spectrometry as a simple and rapid method to measure the plasma propofol concentrations for intravenous anaesthesia monitoring

    Science.gov (United States)

    Wang, Xin; Zhou, Qinghua; Jiang, Dandan; Gong, Yulei; Li, Enyou; Li, Haiyang

    2016-11-01

    The plasma propofol concentration is important information for anaesthetists to monitor and adjust the anaesthesia depth for patients during a surgery operation. In this paper, a stand-alone ion mobility spectrometer (IMS) was constructed for the rapid measurement of the plasma propofol concentrations. Without any sample pre-treatment, the plasma samples were dropped on a piece of glass microfiber paper and then introduced into the IMS cell by the thermal desorption directly. Each individual measurement could be accomplished within 1 min. For the plasma propofol concentrations from 1 to 12 μg mL-1, the IMS response was linear with a correlation coefficient R2 of 0.998, while the limit of detection was evaluated to be 0.1 μg mL-1. These measurement results did meet the clinical application requirements. Furthermore, other clinically-often-used drugs, including remifentanil, flurbiprofen and atracurium, were found no significant interference with the qualitative and quantitative analysis of the plasma propofol. The plasma propofol concentrations measured by IMS were correlated well with those measured by the high performance liquid chromatography (HPLC). The results confirmed an excellent agreement between these two methods. Finally, this method was applied to monitor the plasma propofol concentrations for a patient undergoing surgery, demonstrating its capability of anaesthesia monitoring in real clinical environments.

  14. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  15. Monitoring system for OpenPBS environment

    Energy Technology Data Exchange (ETDEWEB)

    Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)

    2004-11-21

    The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.

  16. Economic analysis of condition monitoring systems for offshore wind turbine sub-systems

    DEFF Research Database (Denmark)

    May, Allan; MacMillan, David; Thöns, Sebastian

    2015-01-01

    The use of condition monitoring systems on offshore wind turbines has increased dramatically in recent times. However, their use is mostly restricted to vibration based monitoring systems for the gearbox, generator and drive train. A survey of commercially available condition monitoring systems...... year life cycle. The model uses Hidden Markov Models to represent both the actual system state and the observed condition monitoring state. The CM systems are modelled to include reduced failure types, false alarms, detection rates and 6 month failure warnings. The costs for system failures are derived...... and their associated costs has been completed for the blades, drive train, tower and foundation. This paper considers what value can be obtained from integrating these additional systems into the maintenance plan. This is achieved by running simulations on an operations and maintenance model for a wind farm over a 20...

  17. PASSIVE SAMPLING OF GROUND WATER MONITORING WELLS WITHOUT PURGING MULTILEVEL WELL CHEMISTRY AND TRACER DISAPPEARANCE

    Science.gov (United States)

    It is essential that the sampling techniques utilized in groundwater monitoring provide data that accurately depicts the water quality of the sampled aquifer in the vicinity of the well. Due to the large amount of monitoring activity currently underway in the U.S.A. it is also im...

  18. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  19. Wide-area, real-time monitoring and visualization system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2013-03-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  20. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  1. RFID and IOT for Attendance Monitoring System

    Directory of Open Access Journals (Sweden)

    Dedy Irawan Joseph

    2018-01-01

    Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.

  2. A New Environmental Monitoring System For Silkworm Incubators

    OpenAIRE

    Alejandra Duque-Torres; Juan Ruiz-Rosero; Gesille Zambrano-Gonzalez; Martha Almanza-Pinzon; Oscar Mauricio Caicedo Rendon; Gustavo Ramirez-Gonzalez

    2018-01-01

    A newly Monitoring Environmental Conditions System is proposed based on Raspberry-Pi. This proposal monitors the temperature, humidity, and luminosity in a silkworm incubator. The monitoring data are collected and save in the cloud for the subsequent analysis. The monitoring environmental system is based on Raspberry Pi due to capabilities, features, and low cost. The preliminary tests were realized in a real scenery and the results demonstrating its reliability.

  3. İletişim Çalışmalarında Yeni Bir Mecra: Finansal İletişim

    Directory of Open Access Journals (Sweden)

    Gökhan Gökgöz

    2013-09-01

    Full Text Available 1970’li yıllar toplumsal ve politik tarih açısından önemli bir uğrağı temsil eder. Bu yılların başında yaşanan kriz, ekonominin işleyiş süreçlerini, devletin yapısını ve toplumsal alanın tasavvur edilme biçimini büyük ölçüde değiştirmiştir. Bu dönemde, finansal sermaye, kapitalizm içerisinde bir hegemonik lider olarak ön plana çıkmış; devlet, bir yandan üretimin çekirdeğinden uzak bir yerde konumlandırılırken diğer yandan paranın dolaşım kanallarının rehabilitasyonu işine odaklanmış; insana ilişkin değerler, kültürel mefhumlar ve toplumsal pratikler ise birer değişken olarak ekonomi-politikanın merkezine taşınmıştır. Kültür ile ekonomi arasındaki geleneksel ilişki bozulmuş; bir ekonomi-politikanın başarısı, toplumsal aktörlere temas etme kabiliyeti ile paralel hale gelmiştir. Finansallaşma sürecinde bu temas, iletişim politikaları vasıtasıyla sağlanır; ekonomi-politika ve bundan sorumlu merkezi kurumlarla toplumsal alan arasındaki bağ, iletişim stratejileri üzerinden kurulur; ekonomik alan ile kültürel alan arasındaki boşluk, iletişim kanalları içerisinden taşınan enformasyon marifetiyle doldurulur; insana ilişkin öngörülemezlikler, iletişim süreçleri vasıtasıyla öngörülebilir kılınır. Bu çalışmada, iletişim çalışmaları içerisinde yeni bir mecra olarak çağrılan “finansal iletişim”in farklı temas noktalarına işaret edilecek ve her bir uğrağın finansal iletişim alanına bağlandığı nokta, modeller üzerinden gösterilecektir. 

  4. Implant Angle Monitor System of MC3-II

    International Nuclear Information System (INIS)

    Sato, Fumiaki; Sano, Makoto; Nakaoka, Hiroaki; Fujii, Yoshito; Kudo, Tetuya; Nakanishi, Makoto; Koike, Masazumi; Fujino, Yasushi

    2008-01-01

    Precise implant angle control is required for the latest generation of ion implanters to meet further shrink semiconductor device requirements. Especially, the highest angle accuracy is required for Halo implant process of Logic devices. The Halo implant angle affects the device performance, because slight differences of beam divergence change the overlap profile towards the extension. Additionally, twist angle accuracy is demanded in case of channeling angle implant. Therefore monitoring beam angles and wafer twist angles is important. A new monitoring system for the MC3-II, SEN Corp.'s single wafer type medium current implanter has been developed. This paper describes the angle control performance and monitoring system of the MC3-II. For the twist angle control, we developed a wafer notch angle monitor. The system monitors the wafer notch image on the platen. And the notch angle variation is calculated by using image processing method. It is also able to adjust the notch angle according to the angle error. For the tilt angle control, we developed a vertical beam profile monitor. The monitor system can detect beam profile of vertical directions with horizontally scanning beam. It also measures beam angles of a tilt direction to a wafer. The system configuration and sample beam data are presented.

  5. A Chinese translation of IMS Learning Design Best Practice and Implementation Guide (draft)

    NARCIS (Netherlands)

    Gong, Yufeng

    2006-01-01

    Many Chinese researchers, system developers and e-learning practitioners have difficulties to understand IMS LD correctly because of language barriers. The main aim of this translation is to help chinese people to overcome the difficulties. It is also expected that this translation can launch into a

  6. Ein Ausblick auf Supply-Chain-Management im Jahr 2016

    DEFF Research Database (Denmark)

    Wieland, Andreas

    2016-01-01

    Wie sieht Supply-Chain-Management im Jahr 2016 aus? Was erwartet uns? Vieles deutet darauf hin, dass SCM in Zukunft sogar noch mehr auf den Kunden gerichtet sein könnte als bisher.......Wie sieht Supply-Chain-Management im Jahr 2016 aus? Was erwartet uns? Vieles deutet darauf hin, dass SCM in Zukunft sogar noch mehr auf den Kunden gerichtet sein könnte als bisher....

  7. ZPR-9 airborne plutonium monitoring system

    International Nuclear Information System (INIS)

    Rusch, G.K.; McDowell, W.P.; Knapp, W.G.

    1975-01-01

    An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved

  8. Report on converging insert moulding with µ-IM

    DEFF Research Database (Denmark)

    Islam, Aminul

    moulding with µ-IM  Task 5.2.1 and COTECH demonstrator: guide line for 5PRC production based on the concept of Task 5.2.1 Information and results provided by this deliverable will be directly used for one of the COTECH demonstrators production which will call for convergent insert moulding with µ......Task 5.2.1 deals with the technical feasibility of converging the state-of-the-art µ IM process with insert moulding to offer a wide range of multi-material µ components. The main objective of this deliverable is to summarize state-of-the-art information and to make the guideline needed...... for the convergence. In particular the following aspects are summed up in the deliverable:  Need for converging insert moulding with µ-IM  Objectives and expected outcome from task 5.2.1  State-of-the-art micro insert moulding and different scenario of micro insert moulding  Challenges ahead of converging insert...

  9. IDEA-system - a new computer based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2005-01-01

    Full text: There is an increasing number of national and international recommendations and guidelines for incorporation monitoring (ICRP Publications, IAEA Safety Reports, ISO Standards, etc.). These recommendations cover different phases of incorporation monitoring and they provide general requirements for the measuring techniques, the monitoring procedures and for the procedures to evaluate intakes and doses from the monitoring results. There is, however, still a strong need for giving guidance to the dosimetrists on how to apply all the regulations properly. Thus, the EU project IDEAS was launched in order to provide general guidelines for the assessment of internal dose from incorporation monitoring data. These guidelines have recently been discussed in a virtual workshop on the internet (www.ideas-workshop.de) and they are being considered by ICRP for possible adoption in the near future. Recently, in the Karlsruhe Research Centre, a computer-based expert system has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for incorporation monitoring and internal dosimetry. The expert system gives guidance to the user with respect to: planning of monitoring (estimation of potential exposures, decision on the requirements of monitoring, definition of optimum measuring techniques and monitoring intervals); performing routine and special monitoring and evaluation of primary monitoring results. The evaluation of primary monitoring results is done according to the IDEAS guidelines in a threestage procedure according to the expected level of exposure (E = committed effective dose): standard evaluation with default or site specific parameter values (E 6 mSv). With these well-defined procedures the expert system follows the aim, that all recommendations and guidelines are applied properly and thus: internal exposures of more than 1 mSv are very likely to be detected in all situations; the results in terms of committed effective

  10. Demonstrating the use of high-volume electronic medical claims data to monitor local and regional influenza activity in the US.

    Directory of Open Access Journals (Sweden)

    Cécile Viboud

    Full Text Available Fine-grained influenza surveillance data are lacking in the US, hampering our ability to monitor disease spread at a local scale. Here we evaluate the performances of high-volume electronic medical claims data to assess local and regional influenza activity.We used electronic medical claims data compiled by IMS Health in 480 US locations to create weekly regional influenza-like-illness (ILI time series during 2003-2010. IMS Health captured 62% of US outpatient visits in 2009. We studied the performances of IMS-ILI indicators against reference influenza surveillance datasets, including CDC-ILI outpatient and laboratory-confirmed influenza data. We estimated correlation in weekly incidences, peak timing and seasonal intensity across datasets, stratified by 10 regions and four age groups (<5, 5-29, 30-59, and 60+ years. To test IMS-Health performances at the city level, we compared IMS-ILI indicators to syndromic surveillance data for New York City. We also used control data on laboratory-confirmed Respiratory Syncytial Virus (RSV activity to test the specificity of IMS-ILI for influenza surveillance.Regional IMS-ILI indicators were highly synchronous with CDC's reference influenza surveillance data (Pearson correlation coefficients rho≥0.89; range across regions, 0.80-0.97, P<0.001. Seasonal intensity estimates were weakly correlated across datasets in all age data (rho≤0.52, moderately correlated among adults (rho≥0.64 and uncorrelated among school-age children. IMS-ILI indicators were more correlated with reference influenza data than control RSV indicators (rho = 0.93 with influenza v. rho = 0.33 with RSV, P<0.05. City-level IMS-ILI indicators were highly consistent with reference syndromic data (rho≥0.86.Medical claims-based ILI indicators accurately capture weekly fluctuations in influenza activity in all US regions during inter-pandemic and pandemic seasons, and can be broken down by age groups and fine geographical areas

  11. Development of the simulation monitoring system

    International Nuclear Information System (INIS)

    Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo

    2001-01-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)

  12. Application of Video Recognition Technology in Landslide Monitoring System

    Directory of Open Access Journals (Sweden)

    Qingjia Meng

    2018-01-01

    Full Text Available The video recognition technology is applied to the landslide emergency remote monitoring system. The trajectories of the landslide are identified by this system in this paper. The system of geological disaster monitoring is applied synthetically to realize the analysis of landslide monitoring data and the combination of video recognition technology. Landslide video monitoring system will video image information, time point, network signal strength, power supply through the 4G network transmission to the server. The data is comprehensively analysed though the remote man-machine interface to conduct to achieve the threshold or manual control to determine the front-end video surveillance system. The system is used to identify the target landslide video for intelligent identification. The algorithm is embedded in the intelligent analysis module, and the video frame is identified, detected, analysed, filtered, and morphological treatment. The algorithm based on artificial intelligence and pattern recognition is used to mark the target landslide in the video screen and confirm whether the landslide is normal. The landslide video monitoring system realizes the remote monitoring and control of the mobile side, and provides a quick and easy monitoring technology.

  13. Corral Monitoring System assessment results

    International Nuclear Information System (INIS)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system

  14. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  15. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  16. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  17. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  18. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  19. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  20. Digital Medien im Naturwissenschaftlichen Unterricht

    CERN Document Server

    Meßinger-Koppelt, Jenny

    2014-01-01

    „Morgens, 8 Uhr: Kurz vor der Schultür werden noch die neuesten Posts auf Facebook geliked, ein Selfie in die Whats-App-Gruppe hochgeladen oder auf YouTube noch ein #LOL-Video gestreamed. Dann klingelt es und die Digital Natives greifen wieder zu Stift, Papier und werden frontal mit Fakten gefüttert“ (A. Spang). Für Schüler sind Internet, Smartphone und Tablet-PC heute selbstverständlicher Teil ihrer Lernwelt. Und auch die Alltags- und Berufswelt ist ohne Informationstechnologien nicht mehr vorstellbar. Doch was bedeutet das für den Schulunterricht, insbesondere für die techniknahen Naturwissenschaften? Wie gelingt im Schulalltag die Balance zwischen Kreidezeit und interaktivem Whiteboard nach mittlerweile 30 Jahren Erfahrung mit Schulcomputern? Der vorliegende Sammelband präsentiert zahlreiche Praxisbeispiele aus dem Schulalltag zum sinnvollen Einsatz digitaler Medien im Biologie-, Chemie- und Physik-Unterricht sowie den aktuellen Stand der fachdidaktischen Forschung. Zu Wort kommen Hochschullehr...

  1. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  2. Upgrade of the monitoring system of LHCb ECAL

    CERN Document Server

    Guz, Iouri; Chernov, Evgeny; Egorychev, Victor; Kandybei, Sergii; Kvaratskheliya, Tengiz; Obraztsov, Vladimir; Perret, Pascal; Philippov, Sergey; Savrina, Daria; Shatalov, Sppavel; Zakoriuchkina, Tatiana; Zhokhov, Anatoli; Zvyagintsev, Serguei

    2016-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.686.24 m2 area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartz fibers. The design of the upgraded version of the LHCb ECAL monitoring system is described here. The usage and performance of the new system for the ECAL calibration during the LHCb Run II are discussed.

  3. System and Method for Monitoring Distributed Asset Data

    Science.gov (United States)

    Gorinevsky, Dimitry (Inventor)

    2015-01-01

    A computer-based monitoring system and monitoring method implemented in computer software for detecting, estimating, and reporting the condition states, their changes, and anomalies for many assets. The assets are of same type, are operated over a period of time, and outfitted with data collection systems. The proposed monitoring method accounts for variability of working conditions for each asset by using regression model that characterizes asset performance. The assets are of the same type but not identical. The proposed monitoring method accounts for asset-to-asset variability; it also accounts for drifts and trends in the asset condition and data. The proposed monitoring system can perform distributed processing of massive amounts of historical data without discarding any useful information where moving all the asset data into one central computing system might be infeasible. The overall processing is includes distributed preprocessing data records from each asset to produce compressed data.

  4. Timing and control monitor system upgrade design document. Version 4

    International Nuclear Information System (INIS)

    Brandt, J.J.

    1984-01-01

    This is a design document for the Timing and Control Monitor System Upgrade Project. This project is intended to provide a replacement system for the existing user Encoder Monitor Systems and Varian 72 Control Room computer systems. All of these systems reside at the Nevada Test Site. The function of the T and C Monitor System is to gather real-time statistics and data on user defined key variables from control, communication, data acquistion systems, and from the monitoring system itself. The control, communication, and data acquisition systems each operate separately from the monitor system. The T and C Monitor System gathers this data in order to verify the readiness of an event to begin countdown. This includes setup, verification, calibration, and peripheral services, report any failures that may occur during the countdown, verify detonation and containment, and assist reentry activities after the event

  5. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  6. Supervisory monitoring system in nuclear power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1997-01-01

    Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs

  7. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  8. Remote monitoring of VRLA batteries for telecommunications systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsujikawa, Tomonobu; Matsushima, Toshio [NTT Facilities Inc., G.H.Y. Building, 2-13-1 Kita-Otsuka, Toshima-ku, Tokyo 170-0004 (Japan)

    2007-05-25

    This paper describes a remote monitoring system that can be set up in an operating center to monitor the state of valve regulated lead acid batteries (VRLA) used as a backup power supply for telecommunications. This system has a battery voltage monitoring function, a lifetime prediction function based on ambient temperature, and a discharge circuit diagnosis function. In addition, the system can be equipped with an internal resistance measurement function and an electrolyte leakage detection function to further insure power-supply reliability. Various states of batteries observed with the system are transmitted to the remote operating center by a remote monitoring function. This function enables obtaining immediate information about the condition of batteries and helps to avoid unexpected failures. (author)

  9. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  10. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  11. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  12. Detection of microbial volatile organic compounds (MVOC) by means of ion mobility spectroscopy (IMS); Detektion leicht fluechtiger organischer Verbindungen mikrobiellen Ursprungs (MVOC) mittels Ionenmobilitaetsspektrometrie (IMS)

    Energy Technology Data Exchange (ETDEWEB)

    Tiebe, Carlo

    2010-07-01

    Traces of microbial volatile organic compounds (MVOCs) can indicate the growth of moulds in the indoor air. The application of ion mobility spectrometry (IMS) is a very promising method for the detection of these MVOCs due to its high sensitivity. A mobile IMS device was tested to use this analytical-chemical method for in situ indoor air diagnostics. The first part of this work describes the test gas generation of 14 MVOCs in the laboratory. The test gases were produced by preparation of permeation procedures. Due to the MVOCs test gases IMS parameters like reduced mobility (K{sub 0}), relative drift time (t{sub rd}), the concentration dependency of MVOCs signals were determined and the limit of detection (LOD) was calculated. The LODs are in the range of 2 to 192 {mu}g m{sup -3} (1 to 51 ppb{sub V}). In the second part of this manuscript seven different mould species were cultivated on nutrient media and their MVOCs emissions were explored. It was found out, that the MVOCs emissions of moulds have a dependency of species and of their cultivation time. These results are confirmed by principal component analysis (PCA). The identification of these MVOCs was performed by test-related GC-MS analysis and approved these results. The MVOCs emissions were explored in the cultivation of mould mixtures on three different building materials. The IMS-results were interpreted chemo metrically by PCA. It was possible to find different emission patterns of cultivated moulds on building materials without an identification of the MVOCs inside the emission chamber. In 27 field trials of different indoor environments (rooms) the IMS was tested to detect MVOCs. In 59 % of the cases a positive correlation is determined between visible mould-infested rooms and the detected MVOCs by IMS. (orig.)

  13. Underground seasonal storage of industrial waste heat; Saisonale Speicherung industrieller Abwaerme im Untergrund

    Energy Technology Data Exchange (ETDEWEB)

    Reuss, M.; Mueller, J. [Bayerische Landesanstalt fuer Landtechnik, TU Muenchen-Weihenstephan, Freising (Germany)

    1998-12-31

    The thermal efficiency of subject systems, especially at higher temperatures is influenced by heat and humidity transport underground. Thermal conductivity and specific thermal capacity depend on the humidity content of the soil. A simulation model was developed that describes the coupled heat and humidity transport in the temperature range up to 90 C. This model will be validated in laboratory and field tests and then be used for designing and analysing underground stores. Pilot plants for the storage of industrial waste heat were designed and planned on the basis of this simulation. In both cases these are cogeneration plants whose waste heat was to be used for space heating and as process energy. Both plants have a very high demand of electric energy which is mostly supplied by the cogeneration plant. The waste heat is put into the store during the summer. In the winter heat is supplied by both the store and the cogeneration plant. In both cases the store has a volume of approx. 15,000 cubic metres with 140 and 210 pits located in a depth of 30 and 40 metres. The plants are used to carry out extensive measurements for the validation of simulation models. (orig.) [Deutsch] Die thermische Leistungsfaehigkeit solcher Systeme wird insbesondere im hoeheren Temperaturbereich durch den Waerme- und Feuchtetransport im Untergrund beeinflusst. Sowohl die Waermeleitfaehigkeit als auch die spezifische Waermekapazitaet sind vom Feuchtegehalt des Bodens abhaengig. Es wurde ein Simulationsmodell entwickelt, das den gekoppelten Waerme- und Feuchtetransport im Temperaturbereich bis 90 C beschreibt. Dieses Modell wird an Labor- und Feldexperimenten validiert und dient dann zur Auslegung und Analyse von Erdwaermesonden-Speichern. Basierend auf diesen theoretischen Grundlagenarbeiten wurden Pilotanlagen zur saisonalen Speicherung industrieller Abwaerme ausgelegt und geplant. In beiden Faellen handelt es sich um Kraft/Waermekopplungsanlagen, deren Abwaerme zur Gebaeudeheizung und

  14. Activity monitoring systems in health care

    NARCIS (Netherlands)

    Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.

    2011-01-01

    This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After

  15. Geological hazard monitoring system in Georgia

    Science.gov (United States)

    Gaprindashvili, George

    2017-04-01

    Georgia belongs to one of world's most complex mountainous regions according to the scale and frequency of Geological processes and damage caused to population, farmlands, and Infrastructure facilities. Geological hazards (landslide, debrisflow/mudflow, rockfall, erosion and etc.) are affecting many populated areas, agricultural fields, roads, oil and gas pipes, high-voltage electric power transmission towers, hydraulic structures, and tourist complexes. Landslides occur almost in all geomorphological zones, resulting in wide differentiation in the failure types and mechanisms and in the size-frequency distribution. In Georgia, geological hazards triggered by: 1. Activation of highly intense earthquakes; 2. Meteorological events provoking the disaster processes on the background of global climatic change; 3. Large-scale Human impact on the environment. The prediction and monitoring of Geological Hazards is a very wide theme, which involves different researchers from different spheres. Geological hazard monitoring is essential to prevent and mitigate these hazards. In past years in Georgia several monitoring system, such as Ground-based geodetic techniques, Debrisflow Early Warning System (EWS) were installed on high sensitive landslide and debrisflow areas. This work presents description of Geological hazard monitoring system in Georgia.

  16. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  17. [Photoionization ion mobility spectrometry (UV-IMS) for the isomeric volatile organic compounds].

    Science.gov (United States)

    Li, Hu; Niu, Wen-qi; Wang, Hong-mei; Huang, Chao-qun; Jiang, Hai-he; Chu, Yan-nan

    2012-01-01

    The construction and performance study is reported for a newly developed ultraviolet photoionization ion mobility spectrometry (UV-IMS). In the present paper, an UV-IMS technique was firstly developed to detect eleven isomeric volatile organic compounds including the differences in the structure of carbon chain, the style of function group and the position of function group. Their reduced mobility values were determined and increased in this order: linears alcohols homemade UV-IMS was around ppb-ppm.

  18. [Einheit und Vielfalt in der Rechtsgeschichte im Ostseeraum] / Marelle Leppik

    Index Scriptorium Estoniae

    Leppik, Marelle

    2013-01-01

    Arvustus: Einheit und Vielfalt in der Rechtsgeschichte im Ostseeraum. Unity and plurality in the legal history of the Baltic Sea area Sechster Rechtshistorikertag im Ostseeraum, 3.-5. Juni 2010 Tartu (Estland) / Riga (Lettland9. Hrsg. von Marju Luts-Sootak, Sanita Osipova und Frank L. Schäfer. (Rechtshistorische Reihe, Bd. 428.) Land. Frankfurt am Main u. a. 2012

  19. Frauen im Netz weltweit – ausgegrenzt und mittendrin

    Directory of Open Access Journals (Sweden)

    Sigrid Peuker

    2003-03-01

    Full Text Available Mit dem Global Center for Women’s Studies and Politics (GLOW ist das Feministische Institut der Heinrich-Böll-Stiftung 1998 online gegangen. Mit diesem Schritt wurden Fragen nach den Möglichkeiten und Grenzen sowie nach den Gestaltungsräumen virtueller Kommunikation für Frauen zentral. Mit feminist_spaces. Frauen im Netz. Diskurse – Communities – Visionen, legt die Heinrich-Böll-Stiftung zusammen mit dem Feministischen Institut Antworten aus internationaler Perspektive vor. Das Buch geht auf die gleichnamige zweitätige Konferenz in Berlin im November 2001 zurück.

  20. Efficient network monitoring for large data acquisition systems

    International Nuclear Information System (INIS)

    Savu, D.O.; Martin, B.; Al-Shabibi, A.; Sjoen, R.; Batraneanu, S.M.; Stancu, S.N.

    2012-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed realtime data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and seamlessly integrates complementary data from auxiliary tools, such as NAGIOS, information services or custom databases. A number of techniques (e.g. normalization, aggregation and data caching) were used in order to improve the user interface response time. The end result is a unified monitoring interface, for fast and uniform access to system statistics, which significantly reduced the time spent by experts for ad-hoc and post-mortem analysis. (authors)

  1. Signal Processing for Indian and Pakistan Nuclear Tests Recorded at IMS Stations Located in Israel

    Science.gov (United States)

    Gitterman, Y.; Pinsky, V.; Hofstetter, R.

    - In compliance with the Comprehensive Nuclear-Test-Ban-Treaty (CTBT) the International Monitoring System (IMS) was designed for detection and location of the clandestine Nuclear Tests (NT). Two auxiliary IMS seismic stations MRNI and EIL, deployed recently, were subjected to detectability, travel-time calibration and discrimination analysis. The study is based on the three recent 1998 underground nuclear explosions: one of India and two of Pakistan, which provided a ground-truth test of the existing IMS. These events, attaining magnitudes of 5.2, 4.8 and 4.6 correspondingly, were registered by many IMS and other seismic stations.The MRNI and EIL broadband (BB) stations are located in Israel at teleseismic distances (from the explosions) of 3600, 2800 and 2700km, respectively, where the signals from the tests are already weak. The Indian and the second Pakistan NT were not detected by the short-period Israel Seismic Network (ISN), using standard STA/LTA triggering. Therefore, for the chosen IMS stations we compare the STA/LTA response to the results of the more sensitive Murdock-Hutt (MH) and the Adaptive Statistically Optimal Detector (OD) that showed triggering for these three events. The second Pakistan NT signal arrived at the ISN and the IMS stations in the coda of a strong Afghanistan earthquake and was further disturbed by a preceding signal from a local earthquake. However, the NT signal was successfully extracted at EIL and MRNI stations using MH and OD procedures. For comparison we provide the signal analysis of the cooperating BB station JER, with considerably worse noise conditions than EIL and MRNI, and show that OD can detect events when the other algorithms fail. Using the most quiet EIL station, the most sensitive OD and different bandpass filters we tried in addition to detect the small Kazakh chemical 100-ton calibration explosion of 1998, with magnitude 3.7 at a distance approaching 4000km. The detector response curve showed uprising in the

  2. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  3. User interface design and system integration aspects of core monitoring systems

    International Nuclear Information System (INIS)

    Berg, O.; Bodal, T.; Hornaes, A.; Porsmyr, J.

    2000-01-01

    The present paper describes our experience with the SCORPIO core monitoring system using generic building blocks for the MMI and system integration. In this context the different layers of the software system are discussed starting with the communication system, interfacing of various modules (e.g. physics codes), administration of several modules and generation of graphical user interfaces for different categories of end-users. A method by which re-use of software components can make the system development and maintenance more efficient is described. Examples are given from different system installation projects. The methodology adopted is considered particularly important in the future, as it is anticipated that core monitoring systems will be expanded with new functions (e.g. information from technical specifications, procedures, noise analysis, etc). Further, efficient coupling of off-line tools for core physics calculations and on-line modules in core monitoring can pave the way for cost savings. (authors)

  4. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  5. 296-B-10 stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1995-01-01

    B Plant Administration Manual, requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with stack 296-B-10 at B Plant. The ventilation system of WESF (Waste Encapsulation and Storage Facility) is designed to provide airflow patterns so that air movement throughout the building is from areas of lesser radioactivity to areas of greater radioactivity. All potentially contaminated areas are maintained at a negative pressure with respect to the atmosphere so that air flows into the building at all times. The exhaust discharging through the 296-B-10 stack is continuously monitored and sampled using a sampling and monitoring probe assembly located approximately 17.4 meters (57 feet) above the base of the stack. The probe assembly consists of 5 nozzles for the sampling probe and 2 nozzles to monitor the flow. The sampling and monitoring system associated with Stack 296-B-10 is functional and performing satisfactorily

  6. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  7. IDEA system - a new computer-based expert system for incorporation monitoring

    International Nuclear Information System (INIS)

    Doerfel, H.

    2007-01-01

    Recently, at the Karlsruhe Research Centre, a computer-based expert system, Internal Dose Equivalent Assessment System (IDEA System), has been developed for assisting dosimetrists in applying the relevant recommendations and guidelines for internal dosimetry. The expert system gives guidance to the user with respect to: (a) planning of monitoring, (b) performing routine and special monitoring, and (c) evaluation of primary monitoring results. The evaluation is done according to the IDEA System guidelines (Doerfel, H. et al., General guidelines for the estimation of committed effective dose from incorporation monitoring data. Research Report FZKA 7243, Research Center Karlsruhe, Karlsruhe (2006). ISSN 0947-8260.) in a three-stage procedure according to the expected level of exposure. At the first level the evaluation is performed with default or site-specific parameter values, at the second level case-specific parameter values are applied and at the third level a special evaluation is performed with individual adjustment of model parameter values. With these well-defined procedures the expert system follows the aim, in which all recommendations and guidelines are applied properly and the results in terms of committed effective and organ doses are close to the best estimate. (author)

  8. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2005-01-01

    Full text: Individual monitoring services in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonization existing in individual monitoring practices in Europe has been achieved mainly thank to documents as standards or international recommendations, which with a different weight, represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonization is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). If used for approval, passing one will not necessarily mean passing all. Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not itself assure that dose results are reliable. This might apply only to ISO/IEC17025 'quality' standard, which represents the best available tool for the quality of laboratory work and somehow include all technical and management requirements. When accredited according to ISO/IEC17025, an Individual Monitoring Service (IMS) fulfils standards. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonization of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. A standard, unlike a textbook or technical publication, does not cover the experience and opinion of one or few individuals only, but the consensus of the entire scientific and technical community concerned. Most of the standards applicable to individual monitoring are published by IEC or ISO, or both together. However, it has to be kept in mind that ISO and IEC standards, for example, are meant for manufactures and industry, which do not

  9. Monitoring solar-thermal systems: An outline of methods and procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, A. [New Mexico State Univ., Las Cruces, NM (United States). Southwest Technology Development Inst.

    1994-04-01

    This manual discusses the technical issues associated with monitoring solar-thermal systems. It discusses some successful monitoring programs that have been implemented in the past. It gives the rationale for selecting a program of monitoring and gives guidelines for the design of new programs. In this report, solar thermal monitoring systems are classified into three levels. For each level, the report discusses the kinds of information obtained by monitoring, the effort needed to support the monitoring program, the hardware required, and the costs involved. Ultimately, all monitoring programs share one common requirement: the collection of accurate data that characterize some aspect or aspects of the system under study. This report addresses most of the issues involved with monitoring solar thermal systems. It does not address such topics as design fundamentals of thermal systems or the relative merits of the many different technologies employed for collection of solar energy.

  10. Best Management Practices Monitoring Guide for Stream Systems

    OpenAIRE

    Mesner, Nancy

    2011-01-01

    Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.

  11. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  12. The design of radiation monitor passageway system

    International Nuclear Information System (INIS)

    Chu Chengsheng

    2006-10-01

    The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)

  13. Associations between United States Medical Licensing Examination (USMLE) and Internal Medicine In-Training Examination (IM-ITE) scores.

    Science.gov (United States)

    McDonald, Furman S; Zeger, Scott L; Kolars, Joseph C

    2008-07-01

    Little is known about the associations of previous standardized examination scores with scores on subsequent standardized examinations used to assess medical knowledge in internal medicine residencies. To examine associations of previous standardized test scores on subsequent standardized test scores. Retrospective cohort study. One hundred ninety-five internal medicine residents. Bivariate associations of United States Medical Licensing Examination (USMLE) Steps and Internal Medicine In-Training Examination (IM-ITE) scores were determined. Random effects analysis adjusting for repeated administrations of the IM-ITE and other variables known or hypothesized to affect IM-ITE score allowed for discrimination of associations of individual USMLE Step scores on IM-ITE scores. In bivariate associations, USMLE scores explained 17% to 27% of the variance in IME-ITE scores, and previous IM-ITE scores explained 66% of the variance in subsequent IM-ITE scores. Regression coefficients (95% CI) for adjusted associations of each USMLE Step with IM-ITE scores were USMLE-1 0.19 (0.12, 0.27), USMLE-2 0.23 (0.17, 0.30), and USMLE-3 0.19 (0.09, 0.29). No single USMLE Step is more strongly associated with IM-ITE scores than the others. Because previous IM-ITE scores are strongly associated with subsequent IM-ITE scores, appropriate modeling, such as random effects methods, should be used to account for previous IM-ITE administrations in studies for which IM-ITE score is an outcome.

  14. Development of distributed plant monitoring and diagnosis system at Monju

    International Nuclear Information System (INIS)

    Okusa, Kyoichi; Tamayama, Kiyoshi; Kitamura, Tomomi

    2003-01-01

    In a nuclear plant, it is required to detect an anomaly as early as possible and to inhibit adverse consequences. This requirement is especially important for a prototype Fast Breeder Reactor Monju. Therefore, a monitoring and diagnosis system is required to be developed for Monju plant equipments. In these days, such a monitoring and diagnosis system can be realized using Web technology with rationalized system resources due to the remarkable progress of computer network technology. Then, we developed a Web based platform for the monitoring and diagnosis system of Monju. Distributed architecture, standardization and highly flexible system structure have been taken account of in the development. This newly developed platform and prototype monitoring and diagnosis systems have been validated. Prototype monitoring and diagnosis systems on the platform acquire Monju plant data and display the data on client computers using Monju intranet with acceptable delay times. The prototype monitoring and diagnosis systems for Monju have been developed on the platform and the whole system has been validated. (author)

  15. Design Of Pump Monitoring Of Primary Cooling System

    International Nuclear Information System (INIS)

    Indrakoesoema, Koes; Sujarwono

    2000-01-01

    Monitoring of 3 primary cooling pumps done visually by operator on the spot. The operator must be check oil in a sight glass, oil leakage during pump operation and water leakage. If reaktor power increase about more than 3 MW, the radiation exposure also increase in the primary cell and that's way the operator can not check the pumps. To continuing monitor all pump without delay, one system has been added I.e Closed Circuit Television (CCTV). This system using 3 video camera to monitor 3 pumps and connected to one receiver video monitor by coaxial cable located in Main Control Room. The sequence monitoring can be done by sequential switcher

  16. Expert systems for real-time monitoring and fault diagnosis

    Science.gov (United States)

    Edwards, S. J.; Caglayan, A. K.

    1989-01-01

    Methods for building real-time onboard expert systems were investigated, and the use of expert systems technology was demonstrated in improving the performance of current real-time onboard monitoring and fault diagnosis applications. The potential applications of the proposed research include an expert system environment allowing the integration of expert systems into conventional time-critical application solutions, a grammar for describing the discrete event behavior of monitoring and fault diagnosis systems, and their applications to new real-time hardware fault diagnosis and monitoring systems for aircraft.

  17. Alpha-monitoring system

    International Nuclear Information System (INIS)

    Dincklage, R.D. von

    1982-01-01

    A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)

  18. Wir und die Anderen: Gruppenbezogene Menschenfeindlichkeit im Sport in Sachsen

    OpenAIRE

    Delto, Hannes; Tzschoppe, Petra

    2015-01-01

    Mit der Querschnittsstudie "Wir und die Anderen – Gruppenbezogene Menschenfeindlichkeit im organisierten Sport in Sachsen" wurde erstmals das Syndrom Gruppenbezogener Menschenfeindlichkeit im organisierten Sport untersucht. Das Konzept der Gruppenbezogenen Menschenfeindlichkeit – ausgehend von einer Ideologie der Ungleichwertigkeit – wurde von Prof. Wilhelm Heitmeyer (Universität Bielefeld) entwickelt. Die Ergebnisse ermöglichen explizite Aussagen über Ausmaß und Ursachen Gruppenbezogener Men...

  19. On the use of multi-agent systems for the monitoring of industrial systems

    Science.gov (United States)

    Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil

    2016-03-01

    The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.

  20. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  1. Automated wireless monitoring system for cable tension using smart sensors

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang

    2013-04-01

    Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.

  2. Design of smart neonatal health monitoring system using SMCC.

    Science.gov (United States)

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  3. Diagnostic and monitoring systems in nuclear power plants

    International Nuclear Information System (INIS)

    Wehling, H.J.; Jax, P.; Streicher, V.

    1987-01-01

    Monitoring systems are important for the availability of nuclear power plants. A survey is given about such systems designed and constructed by the Kraftwerk Union AG Erlangen (Federal Republic of Germany) in order to assure the mechanical integrity of reactor cooling systems. Three monitoring systems based on microprocessors are presented: KUES (acoustic detection of loose parts), SUES (vibration), and FAMOS (fatigue)

  4. Monitoring 'renewables'. Use of renewable raw materials in house building. Fourth progress report; Monitoring 'Nachwachsender Rohstoffe'. Einsatz nachwachsender Rohstoffe im Wohnungsbau. Vierter Sachstandsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Roesch, C.

    1999-07-01

    Erecting or acquiring a house or residential unit is one of the most lasting and incisive investments that a man makes in his lifetime. It is, so to speak, the realization of one's dream of independence and security in old age. Appropriately high are expectations on the construction, design, and materials used. Technically fabricated building materials meet these demands: They stand out by high functionality and effectivenesss, ease of handling and long-term stability as well as a long service-life and low prices. As a result, the formerly wide use of natural raw materials in construction has suffered a great setback. The generally positive basic attitude towards modern products has changed somewhat in recent years, however. Today's builders or redevelopers expect not only precise cost information but also information on energy, ecological aspects and health aspects. In contrast to the formerly often one-sided orientation to the investment phase, it is more and more the complete lifecycle of the building that is taken into account. In this way builders react to topical demands for safeguarding sustainable development also in the building sector. (orig.) [German] Die Errichtung bzw. der Erwerb von Haeusern und Wohnungen ist eine der langfristigsten und einschneidensten Investitionen, die der Mensch in seinem Leben taetig. Es ist gleichermassen die Erfuellung des Traumes von der Unabhaengigkeit und Absicherung fuer das Lebensalter. Dementsprechend hohe Erwartungen werden an die Bauweise, die Konstruktionen und eingesetzten Materialien gestellt. Technisch hergestellte Baustoffe erfuellen diese Erwartungen: Sie zeichnen sich durch eine hohe Funktionalitaet und Leistungsfaehigkeit, eine gute Handhabbarkeit und Dauerbestaendigkeit sowie eine lange Lebensdauer und niedrige Preise aus. Dies fuehrte dazu, dass der im Wohnungsbau frueher sehr verbreitete Einsatz natuerlicher Rohstoffe stark zurueckgedraengt wurde. Die allgemeine positive Grundeinstellung gegenueber

  5. Grand Prix Eurovision: Eine Fankultur im Medienzeitalter

    Directory of Open Access Journals (Sweden)

    Heinz Moser

    2017-06-01

    Full Text Available Der Grand Prix Eurovision ist seit Jahrzehnten eine der bekanntesten Unterhaltungssendungen im europäischen Raum. Dennoch erregte es Verwunderung, wenn der Schreibende Bekannten darüber berichtete, daß dies ein Forschungsgegenstand sei. Wurde von Interviews mit Grand Prix-Fans erzählt, so fielen schnell Aussagen wie: „Wie kann man sich nur für so etwas Abseitiges und Triviales wie den Grand Prix interessieren“. Dennoch bin ich der Meinung, daß Fankulturen für die entstehende Mediengesellschaft ein nicht unwichtiges Forschungsthema darstellen. Zwar geht es nicht um eine medienpädagogische Fragestellung im engeren Sinne; die Fans des Grand Prix Eurovision sind dem Jugendalter längst entwachsen. Dennoch handelt es sich bei Fangemeinschaften um Phänomene, die im Rahmen von Jugend- und Kinderkulturen von besonderer Relevanz sind. So meint Winter (1997, daß jugendliche Fanwelten eine bedeutende Rolle als Kristallisationspunkte kultureller Differenzierung spielen: ,Die Zugehörigkeit zu einer Fan weit ist Teil der jugendlichen Lebensbewältigung in der Postmoderne, denn in der Gemeinschaft der Fans können Jugendliche emotionale Allianzen eingehen, außeralltäglichen Beschäftigungen nachgehen, expressive Identitätsmuster gemeinschaftlich realisieren und sich mit ihrer Lebenssituation als Heranwachsende auseinandersetzen“ (Winter 1997, S. 51f..

  6. Recht und Gewalt im internationalen System. Von G. I. Tunkin. (Veröffentlichungen des Instituts für Internationales Recht an der Universität Kiel, Band 93) / Henn-Jüri Uibopuu

    Index Scriptorium Estoniae

    Uibopuu, Henn-Jüri, 1929-2012

    1989-01-01

    Raamatuarvustus: Tunkin, G. I. Recht und Gewalt im internationalen System. - Berlin : Duncker und Humblot, 1986. - (Veröffentlichungen des Instituts für Internationales Recht an der Universität Kiel ; 93). 213 lk.

  7. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  8. Methods, apparatus, and systems for monitoring transmission systems

    Science.gov (United States)

    Polk, Robert E [Idaho Falls, ID; Svoboda, John M [Idaho Falls, ID; West, Phillip B [Idaho Falls, ID; Heath, Gail L [Iona, ID; Scott, Clark L [Idaho Falls, ID

    2010-08-31

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  9. A monitor system for end cap shower counter of Beijing spectrometer

    International Nuclear Information System (INIS)

    Wang Man; Xia Xiaomi; Lai Yuanfen; Cheng Baosen; Li Jin

    1993-01-01

    To keep a large-scale detector system running in a correct condition and to obtain some correct parameters, it is necessary to have a monitor system monitoring the detector system operation in real time. In the paper, the structure of End Cap Shower Counter monitor system of Beijing Spectrometer is described. Some properties of this monitor system and the real-time monitoring results during operation of Beijing Spectrometer are given

  10. Implementation of medical monitor system based on networks

    Science.gov (United States)

    Yu, Hui; Cao, Yuzhen; Zhang, Lixin; Ding, Mingshi

    2006-11-01

    In this paper, the development trend of medical monitor system is analyzed and portable trend and network function become more and more popular among all kinds of medical monitor devices. The architecture of medical network monitor system solution is provided and design and implementation details of medical monitor terminal, monitor center software, distributed medical database and two kind of medical information terminal are especially discussed. Rabbit3000 system is used in medical monitor terminal to implement security administration of data transfer on network, human-machine interface, power management and DSP interface while DSP chip TMS5402 is used in signal analysis and data compression. Distributed medical database is designed for hospital center according to DICOM information model and HL7 standard. Pocket medical information terminal based on ARM9 embedded platform is also developed to interactive with center database on networks. Two kernels based on WINCE are customized and corresponding terminal software are developed for nurse's routine care and doctor's auxiliary diagnosis. Now invention patent of the monitor terminal is approved and manufacture and clinic test plans are scheduled. Applications for invention patent are also arranged for two medical information terminals.

  11. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  12. Remote monitoring system workshop and technical cooperation

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W.

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person

  13. Research and Implementation of Distributed Database HBase Monitoring System

    Directory of Open Access Journals (Sweden)

    Guo Lisi

    2017-01-01

    Full Text Available With the arrival of large data age, distributed database HBase becomes an important tool for storing data in massive data age. The normal operation of HBase database is an important guarantee to ensure the security of data storage. Therefore designing a reasonable HBase monitoring system is of great significance in practice. In this article, we introduce the solution, which contains the performance monitoring and fault alarm function module, to meet a certain operator’s demand of HBase monitoring database in their actual production projects. We designed a monitoring system which consists of a flexible and extensible monitoring agent, a monitoring server based on SSM architecture, and a concise monitoring display layer. Moreover, in order to deal with the problem that pages renders too slow in the actual operation process, we present a solution: reducing the SQL query. It has been proved that reducing SQL query can effectively improve system performance and user experience. The system work well in monitoring the status of HBase database, flexibly extending the monitoring index, and issuing a warning when a fault occurs, so that it is able to improve the working efficiency of the administrator, and ensure the smooth operation of the project.

  14. PC based vibration monitoring system

    International Nuclear Information System (INIS)

    Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.

    2004-01-01

    Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)

  15. Development of an enhanced loose parts monitoring system (LPMS)

    International Nuclear Information System (INIS)

    Choi, Y. C.; Park, J. H.; Yoon, D. B.; Choi, K. S.; Sohn, C. H.

    2006-01-01

    LPMS (loose parts monitoring system) is one of the most important structural integrity monitoring systems. It is operated for a early detection of the impacts by loosened or detached metallic, objects on the primary pressure boundary in a nuclear power plant. The impacted parts might cause flow blockage in the fuel channel, prevent the control rod from moving properly, damage the pump impeller, and give rise to cracks on the steam generator tube sheet, etc. In Korea, The LPMS is currently operating in all of the nuclear power plants as a subsystem in the NIMS (NSSS Integrity Monitoring System), However the performances are being deteriorated in both the hardware and software since it was designed in 1980's. In particular the system is not capable of promptly responding to the continuously triggered impacts in a short period failing to monitor the real loose parts. Also the diagnostic tools to estimate the location and the mass or energy of the impact source have not been reflected. Therefore, a new loose parts monitoring system has been developed to improve the capabilities of the current one and ultimately to replace it. An enhanced Loose Parts Monitoring System(LPMS) has been developed by KAERI(Korea Atomic Energy Research Inst.), not only to improve the performance of an on-line signal processing for a monitoring system but also to enhance the evaluation technique of the true impact signals by loose parts. This new system has taken into account the state-of-the-art technology to cover the problems with the conventional system. (authors)

  16. Environmental monitoring systems: a new type of mobile laboratory

    International Nuclear Information System (INIS)

    Bruecher, L.; Langmueller, G.; Tuerschmann, G.

    1999-01-01

    Nuclear facilities are obligated to monitor the environmental radiation in their vicinity, which is often fulfilled by monitoring cars, combined with fixed monitoring stations. The MOLAR Mobile Laboratory for Environmental Radiation Monitoring as described here is being used under normal and accident conditions as a spot check monitoring system or to perform continuous measurements along a driving track. The mobile laboratories are continuously connected with the control centre's CRCS Central Radiological Computer System, where the RIS Radiological Information System provides corresponding evaluation functions. The mobile labs contain measuring and controlling units like γ-dose rate monitors, γ-spectrometer with a HpGe High Purity Germanium detector, a lead shielded measuring cell and MCA Multi-Channel Analyser, portable β-contamination monitor, α/β/γ multipurpose quick measuring unit, aerosol and iodine sampling units. The collected samples are safely stored for the transport to the environmental laboratory for being analysed later. The geographical location of the moving car is continuously determined by the satellite based GPS Global Positioning System and transferred in the on-board rack mounted computer system for being stored and locally displayed. Real-time data transmission via radio and mobile phone is continuously performed to supply the RIS Radiological Information System in the control centre via radio and mobile phone. The latter also serves for voice communication. Currently three MOLAR systems can be operated parallel and independent from the control centre. The system is ready to be extended to more mobile labs. This combination of mobile monitoring, sample analysis and radiological assessment of environmental data in combination with process occurrences has turned out to be a powerful instrument for emergency preparedness and environmental supervising. (orig.) [de

  17. Design of multi-channel analyzer's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Yang Tao; Wei Yixiang

    2007-01-01

    A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)

  18. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  19. Study on intermediate frequency power supply automatic monitor system

    International Nuclear Information System (INIS)

    Wang Yuntong; Xu Bin

    2007-06-01

    A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)

  20. Down-conversion IM-DD RF photonic link utilizing MQW MZ modulator.

    Science.gov (United States)

    Xu, Longtao; Jin, Shilei; Li, Yifei

    2016-04-18

    We present the first down-conversion intensity modulated-direct detection (IM-DD) RF photonic link that achieves frequency down-conversion using the nonlinear optical phase modulation inside a Mach-Zehnder (MZ) modulator. The nonlinear phase modulation is very sensitive and it can enable high RF-to-IF conversion efficiency. Furthermore, the link linearity is enhanced by canceling the nonlinear distortions from the nonlinear phase modulation and the MZ interferometer. Proof-of-concept measurement was performed. The down-conversion IM-DD link demonstrated 28dB improvement in distortion levels over that of a conventional IM-DD link using a LiNbO3 MZ modulator.

  1. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  2. Development of a new thin film technology for PV systems: Open-system CCSVT process for production of ZnSe/CuGaSe{sub 2} hetero diodes. Final report; Entwicklung einer neuen Duennschichttechnologie fuer die Photovoltaik: CCSVT-Verfahren im offenen System zur Herstellung von ZnSe/CuGaSe{sub 2}-Heterodioden. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lux-Steiner, M.C.; Jaeger-Waldau, A.

    2000-07-01

    A new technology for fast, large-surface deposition of high-quality semiconducting thin films for PV systems. The new technology, CSVT (close-space vapour transport), is based on a combination of VPE (vapour phase epitaxy) in open systems and CVT (chemical vapour phase transport) in closed systems. The two-source CVD experiments with two different transport gases, i.e. Cu{sub 2}Se with iodine and Ga{sub 2}Se{sub 3} with HCl, enabled controlled variation of the Cu:Ga ratio in the gaseous phase. The solar cells produced had efficiencies of more than 4%. The best solar cell produced had an efficiency of 4.8% and an open terminal voltage of 863 mV. [German] Ziel des Vorhabens war die Entwicklung einer neuen Technologie zur schnellen, grossflaechigen Abscheidung von qualitativ hochstehenden, halbleitenden Duennschichten fuer die Photovoltaik. Das Konzept des neuen Abscheideverfahrens, CSVT (close-space vapour transport) im offenen System, basiert auf einer Kombination der etablierten Methoden VPE (vapour phase epitaxy) im offenen und CVT (chemical vapour phase transport) im geschlossenen System. Die 2-Quellen-CVD-Experimente mit den zwei unterschiedlichen Transportgasen (Cu{sub 2}Se mit Iod; Ga{sub 2}Se{sub 3} mit HCl) ermoeglichten die kontrollierte Variation des Cu:Ga=Verhaeltnisses in der Gasphase. Bisher konnten so Solarzellen mit Wirkungsgraden ueber 4% hergestellt werden, wobei bei der bisher besten Solarzelle ein Wirkungsgrad von {eta}=4.8% und eine offene Klemmenspannung von V{sub oc}=863 mV erreicht wurde. (orig.)

  3. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  4. The Wettzell System Monitoring Concept and First Realizations

    Science.gov (United States)

    Ettl, Martin; Neidhardt, Alexander; Muehlbauer, Matthias; Ploetz, Christian; Beaudoin, Christopher

    2010-01-01

    Automated monitoring of operational system parameters for the geodetic space techniques is becoming more important in order to improve the geodetic data and to ensure the safety and stability of automatic and remote-controlled observations. Therefore, the Wettzell group has developed the system monitoring software, SysMon, which is based on a reliable, remotely-controllable hardware/software realization. A multi-layered data logging system based on a fanless, robust industrial PC with an internal database system is used to collect data from several external, serial, bus, or PCI-based sensors. The internal communication is realized with Remote Procedure Calls (RPC) and uses generative programming with the interface software generator idl2rpc.pl developed at Wettzell. Each data monitoring stream can be configured individually via configuration files to define the logging rates or analog-digital-conversion parameters. First realizations are currently installed at the new laser ranging system at Wettzell to address safety issues and at the VLBI station O Higgins as a meteorological data logger. The system monitoring concept should be realized for the Wettzell radio telescope in the near future.

  5. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  6. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  7. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  8. Results from an Interval Management (IM) Flight Test and Its Potential Benefit to Air Traffic Management Operations

    Science.gov (United States)

    Baxley, Brian; Swieringa, Kurt; Berckefeldt, Rick; Boyle, Dan

    2017-01-01

    NASA's first Air Traffic Management Technology Demonstration (ATD-1) subproject successfully completed a 19-day flight test of an Interval Management (IM) avionics prototype. The prototype was built based on IM standards, integrated into two test aircraft, and then flown in real-world conditions to determine if the goals of improving aircraft efficiency and airport throughput during high-density arrival operations could be met. The ATD-1 concept of operation integrates advanced arrival scheduling, controller decision support tools, and the IM avionics to enable multiple time-based arrival streams into a high-density terminal airspace. IM contributes by calculating airspeeds that enable an aircraft to achieve a spacing interval behind the preceding aircraft. The IM avionics uses its data (route of flight, position, etc.) and Automatic Dependent Surveillance-Broadcast (ADS-B) state data from the Target aircraft to calculate this airspeed. The flight test demonstrated that the IM avionics prototype met the spacing accuracy design goal for three of the four IM operation types tested. The primary issue requiring attention for future IM work is the high rate of IM speed commands and speed reversals. In total, during this flight test, the IM avionics prototype showed significant promise in contributing to the goals of improving aircraft efficiency and airport throughput.

  9. A critical analysis of Sorrell v. IMS Health, Inc.: Pandora's box at best.

    Science.gov (United States)

    Bibet-Kalinyak, Isabelle

    2012-01-01

    Sorrell v. IMS Health, Inc. ("IMS Health"), a remarkable health care case with resounding First Amendment and economic repercussions, features the clashing interests of the State of Vermont and aggressive free market players from the pharmaceutical and data mining industries in a constitutional battle over Free Speech. In 2007, Vermont enacted Act 80, The Confidentiality of Prescription Information Act, prohibiting the sale, disclosure, and use of pharmacy records. Together with two other data miners and PhRMA, an association of brand-name drug manufacturers, IMS Health successfully challenged the constitutionality of Act 80 on First Amendment grounds. This article examines the legal arguments of IMS Health and Act 80 and analyzes why IMS Health stands out for potentially challenging the traditional doctrine of commercial speech and the resulting legal implications. After reviewing the Supreme Court's reasoning, the article concludes that, although the Supreme Court reached the appropriate outcome, it did so by unjustifiably departing from the established legal doctrine of commercial speech and the American tradition of consumer protection. At best, IMS Health's reasoning opens a legal Pandora's Box potentially leading to an onset of new commercial speech challenges; at worst, it manufactured a Trojan Horse aimed at eroding the traditional regulatory safeguards that maintain a balance between the needs of consumers and corporations alike.

  10. A low frequency RFI monitoring system

    Science.gov (United States)

    Amiri, Shahram; Shankar, N. Udaya; Girish, B. S.; Somashekar, R.

    Radio frequency interference (RFI) is a growing problem for research in radio astronomy particularly at wavelengths longer than 2m. For satisfactory operation of a radio telescope, several bands have been protected for radio astronomy observations by the International Telecommunication Union. Since the radiation from cosmic sources are typically 40 to 100 dB below the emission from services operating in unprotected bands, often the out-of-band emission limits the sensitivity of astronomical observations. Moreover, several radio spectral emissions from cosmic sources are present in the frequency range outside the allocated band for radio astronomy. Thus monitoring of RFI is essential before building a receiver system for low frequency radio astronomy. We describe the design and development of an RFI monitoring system operating in the frequency band 30 to 100 MHz. This was designed keeping in view our proposal to extend the frequency of operation of GMRT down to 40 MHz. The monitor is a PC based spectrometer recording the voltage output of a receiver connected to an antenna, capable of digitizing the low frequency RF directly with an 8 bit ADC and sampling bandwidths up to 16 MHz. The system can operate continuously in almost real-time with a loss of only 2% of data. Here we will present the systems design aspects and the results of RFI monitoring carried out at the Raman Research Institute, Bangalore and at the GMRT site in Khodad.

  11. Innovative Techniken und Algorithmen im Bereich Computational-Finance und Risikomanagement

    OpenAIRE

    Liang, Qian

    2012-01-01

    Diese Dissertation besteht aus zwei aktuellen Themen im Bereich Finanzmathematik, die voneinander unabhängig sind. Beim ersten Thema, "Flexible Algorithmen zur Bewertung komplexer Optionen mit mehreren Eigenschaften mittels der funktionalen Programmiersprache Haskell", handelt es sich um ein interdisziplinäres Projekt, in dem eine wissenschaftliche Brücke zwischen der Optionsbewertung und der funktionalen Programmierung geschlagen wurde. Im diesem Projekt wurde eine funktionale Biblio...

  12. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  13. Die Raumdarstellung im erzählenden Werk um 1900

    OpenAIRE

    Lu, Xiaoli

    2011-01-01

    In der Literatur existiert eine eigene Welt, die mit Raum und Zeit verbunden ist. Im 19. Jahrhundert gewinnen beide, Raum und Zeit, an Bedeutung als bewusst eingesetzte Gestaltungselemente. Es bilden sich zwei Grundrichtungen heraus, eine mit dem Erzählgeschehen verknüpfte Semantisierung in der Klassik und in der Romantik und eine betonte Fixierung des Geschehens in der realen Welt durch genaue Zeit- und Ortsangaben im Realismus. Die Semantisierung von Raum und Zeit führt zu einer Bedeutungss...

  14. 296-B-5 Stack monitoring and sampling system annual system assessment report

    International Nuclear Information System (INIS)

    Ridge, T.M.

    1995-02-01

    The B Plant Administration Manual requires an annual system assessment to evaluate and report the present condition of the sampling and monitoring system associated with Stack 296-B-5 at B Plant. The sampling and monitoring system associated with stack 296-B-5 is functional and performing satisfactorily. This document is an annual assessment report of the systems associated with the 296-B-5 stack

  15. [Das Bild und die Wahrnehmung der Stadt und der städtischen Gesellschaft im Hanseraum im Mittelalter und in der frühen Neuzeit] / Juhan Kreem

    Index Scriptorium Estoniae

    Kreem, Juhan

    2009-01-01

    Arvustus: Das Bild und die Wahrnehmung der Stadt und der städtischen Gesellschaft im Hanseraum im Mittelalter und in der frühen Neuzeit. hrsg. v. Roman Czaja. Torun, 2004. Torunis 2002. aastal toimunud konverentsi materjalid. Projekti "Pilt ja linn" raames ilmunud publikatsioonide loendit saab näha aadressil http://www.historiaurbium.org/english/attivita_images_en.html.

  16. EDGAR, a new plant radiation monitoring system

    International Nuclear Information System (INIS)

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  17. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  18. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    Energy Technology Data Exchange (ETDEWEB)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P

    2006-09-15

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO{sub 2} into U-metal. For demonstration of this process, {alpha}-{gamma} type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for {gamma}-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  19. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    International Nuclear Information System (INIS)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-09-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for γ-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration

  20. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  1. Quaternion Based Thermal Condition Monitoring System

    Science.gov (United States)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  2. Integrated monitoring of wind plant systems

    Science.gov (United States)

    Whelan, Matthew J.; Janoyan, Kerop D.; Qiu, Tong

    2008-03-01

    Wind power is a renewable source of energy that is quickly gaining acceptance by many. Advanced sensor technologies have currently focused solely on improving wind turbine rotor aerodynamics and increasing of the efficiency of the blade design and concentration. Alternatively, potential improvements in wind plant efficiency may be realized through reduction of reactionary losses of kinetic energy to the structural and substructural systems supporting the turbine mechanics. Investigation of the complete dynamic structural response of the wind plant is proposed using a large-scale, high-rate wireless sensor network. The wireless network enables sensors to be placed across the sizable structure, including the rotating blades, without consideration of cabling issues and the economic burden associated with large spools of measurement cables. A large array of multi-axis accelerometers is utilized to evaluate the modal properties of the system as well as individual members and would enable long-term structural condition monitoring of the wind turbine as well. Additionally, environmental parameters, including wind speed, temperature, and humidity, are wirelessly collected for correlation. Such a wireless system could be integrated with electrical monitoring sensors and actuators and incorporated into a remote multi-turbine centralized plant monitoring and control system.

  3. Implementation of remove monitoring in facilities under safeguards with unattended systems

    International Nuclear Information System (INIS)

    Beddingfield, David H.; Nordquist, Heather A.; Umebayaashi, Eiji

    2009-01-01

    Remote monitoring is being applied by the International Atomic Energy Agency (IAEA) at nuclear facilities around the world. At the Monju Reactor in Japan we have designed, developed and implemented a remote monitoring approach that can serve as a model for applying remote monitoring to facilities that are already under full-scope safeguards using unattended instrumentation. Remote monitoring implementations have historically relied upon the use of specialized data collection hardware and system design features that integrate remote monitoring into the safeguards data collection system. The integration of remote monitoring and unattended data collection increases the complexity of safeguards data collection systems. This increase in complexity necessarily produces a corresponding reduction of system reliability compared to less-complex unattended monitoring systems. At the Monju facility we have implemented a remote monitoring system that is decoupled from the activity of safeguards data collection. In the completed system the function of remote data transfer is separated from the function of safeguards data collection. As such, a failure of the remote monitoring function cannot produce an associated loss of safeguards data, as is possible with integrated remote-monitoring implementations. Currently, all safeguards data from this facility is available to the IAEA on a 24/7 basis. This facility employs five radiation-based unattended systems, video surveillance and numerous optical seal systems. The implementation of remote monitoring at this facility, while increasing the complexity of the safeguards system, is designed to avoid any corresponding reduction in reliability of the safeguards data collection systems by having decoupled these functions. This design and implementation can serve as a model for implementation of remote monitoring at nuclear facilities that currently employ unattended safeguards systems.

  4. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    OpenAIRE

    Sungjun Kwon; Dongseok Lee; Jeehoon Kim; Youngki Lee; Seungwoo Kang; Sangwon Seo; Kwangsuk Park

    2016-01-01

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user?s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user?s high-level contexts, such as stress and affective state levels. In th...

  5. IMS Mitigation Target Areas - 2010 [ds673

    Data.gov (United States)

    California Natural Resource Agency — Mitigation Target Areas (MTA) were developed by the California Department of Fish and Game for the Interim Mitigation Strategy (IMS). The MTAs are an identification...

  6. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  7. ImNet: a fiber optic network with multistar topology for high-speed data transmission

    Science.gov (United States)

    Vossebuerger, F.; Keizers, Andreas; Soederman, N.; Meyer-Ebrecht, Dietrich

    1993-10-01

    ImNet is a fiber-optic local area network, which has been developed for high speed image communication in Picture Archiving and Communication Systems (PACS). A comprehensive analysis of image communication requirements in hospitals led to the conclusion that there is a need for networks which are optimized for the transmission of large datafiles. ImNet is optimized for this application in contrast to current-state LANs. ImNet consists of two elements: a link module and a switch module. The point-to-point link module can be up to 4 km by using fiber optic cable. For short distances up to 100 m a cheaper module using shielded twisted pair cable is available. The link module works bi-directionally and handles all protocols up to OSI-Level 3. The data rate per link is up to 140 MBit/s (clock rate 175 MHz). The switch module consists of the control unit and the cross-point-switch array. The array has up to fourteen interfaces for link modules. Up to fourteen data transfers each with a maximal transfer rate of 400 MBit/s can be handled at the same time. Thereby the maximal throughput of a switch module is 5.6 GBit/s. Out of these modules a multi-star network can be built i.e., an arbitrary tree structure of stars. This topology allows multiple transmissions at the same time as long as they do not require identical links. Therefore the overall throughput of ImNet can be a multiple of the datarate per link.

  8. MINED GEOLOGIC DISPOSAL SYSTEM (MGDS) MONITORING AND CONTROL SYSTEMS CENTRALIZATION TECHNICAL REPORT

    International Nuclear Information System (INIS)

    M.J. McGrath

    1998-01-01

    The objective of this report is to identify and document Mined Geologic Disposal System (MGDS) requirements for centralized command and control. Additionally, to further develop the MGDS monitoring and control functions. This monitoring and control report provides the following information: (1) Determines the applicable requirements for a monitoring and control system for repository operations and construction (excluding Performance Confirmation). (2) Makes a determination as to whether or not centralized command and control is required

  9. Real time kernel performance monitoring with SystemTap

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    SystemTap is a dynamic method of monitoring and tracing the operation of a running Linux kernel. In this talk I will present a few practical use cases where SystemTap allowed me to turn otherwise complex userland monitoring tasks in simple kernel probes.

  10. Operational experience with two tritium-effluent-monitoring systems

    International Nuclear Information System (INIS)

    Haynie, J.S.; Gutierrez, J.A.

    1982-01-01

    Two new tritium stack monitoring systems were designed and built. The operational experience of a wide-range detector with a useful range of a few μCi/m 3 to 10 8 μCi/m 3 , and a second monitoring system using an improved Kanne chamber and a new electrometer, called a Model 39 Electrometer-Chargemeter are discussed. Both tritium chambers have been designed to have a reduced sensitivity to tritium contamination, a fast response, and an integrating chargemeter with digital readout for easy conversion to microcuries. The calibration of these monitors and advantages of using these chambers over conventional systems are discussed

  11. Quebec firm develops satellite monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2004-09-01

    Satellite-based technology that gives project owners an affordable way to monitor and control wind turbine operation, even in remote sites, is announced. Called Satwind, the system can be adapted to any scale, ranging from simple, low-cost units for small wind turbines to advanced versions designed to handle more complex wind-diesel installations, as well as large turbines used in offshore projects. Current installations include a turbine in the Tunisian desert and two Quebec wind-diesel plants accessible only by helicopter. The system can be operated directly from a cell-phone, in a user-friendly Internet manner, without the need to be connected to a complex centralized wind farm monitoring system.

  12. Performace Of Multi-Probe Corrosion Monitoring Systems At The Hanford Site

    International Nuclear Information System (INIS)

    Carothers, K.D.; Boomer, K.D.; Anda, V.S.; Dahl, M.M.; Edgemon, G.L.

    2010-01-01

    Between 2007 and 2009, several different multi-probe corrosion monitoring systems were designed and installed in high-level nuclear waste tanks at the U.S. Department of Energy's Hanford Site in WaShington State. The probe systems are being monitored to ensure waste tanks operate in regions that minimize localized corrosion (i.e., pitting) and stress corrosion cracking. The corrosion monitoring systems have been installed in wastes with different chemistry types. An ongoing effort during the same time period has generated non-radioactive simulants that are tested in the laboratory to establish baseline corrosion monitoring system performance and characterize data to allow interpretation of readings from the multiple corrosion monitoring systems. Data collection from these monitoring systems has reached the point where the results allow comparison with the laboratory testing. This paper presents analytical results from the corrosion monitoring system development program.

  13. Computerized x-ray dose-monitoring system

    International Nuclear Information System (INIS)

    Hummel, R.H.; Wesenberg, R.L.; Amundson, G.M.

    1985-01-01

    An x-ray dose-monitoring system using a small digital computer is described. Initially, and for every 6 months afterward, the system is calibrated using an exposure meter. For each exposure, the computer receives values of x-ray technique and beam geometry from the x-ray generator through a specially designed electronic interface. Then, by means of calibration data, entrance exposure, area exposure product, and integral dose are obtained and printed for each patient examined. The overall accuracy of the system is better than +/-20%. Operation is semiautomatic, requiring minimum operator intervention. Over 2000 patients have been monitored with the device. Because the system is computer-based, it offers the opportunity for statistical analysis of the data base created, as the results for each patient are stored on computer disk

  14. Background compensation methodologies for contamination monitoring systems

    International Nuclear Information System (INIS)

    Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases

  15. Systems engineering approach towards performance monitoring of emergency diesel generator

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Lee, Y.K.

    2013-01-01

    Full-text: Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort. (author)

  16. G-Cloud Monitor: A Cloud Monitoring System for Factory Automation for Sustainable Green Computing

    Directory of Open Access Journals (Sweden)

    Hwa-Young Jeong

    2014-11-01

    Full Text Available Green and cloud computing (G-cloud are new trends in all areas of computing. The G-cloud provides an efficient function, which enables users to access their programs, systems and platforms at anytime and anyplace. Green computing can also yield greener technology by reducing power consumption for sustainable environments. Furthermore, in order to apply user needs to the system development, the user characteristics are regarded as some of the most important factors to be considered in product industries. In this paper, we propose a cloud monitoring system to observe and manage the manufacturing system/factory automation for sustainable green computing. For monitoring systems, we utilized the resources in the G-cloud environments, and hence, it can reduce the amount of system resources and devices, such as system power and processes. In addition, we propose adding a user profile to the monitoring system in order to provide a user-friendly function. That is, this function allows system configurations to be automatically matched to the individual’s requirements, thus increasing efficiency.

  17. Development of CANDU core monitoring system

    International Nuclear Information System (INIS)

    Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H.

    2003-01-01

    The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1

  18. Development of CANDU core monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, M. Y.; Yeam, C. S.; Kwon, O. H.; Kim, K. H. [Institute for Advanced Engineering, Yongin (Korea, Republic of)

    2003-07-01

    The research was performed to develop a CANDU Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong Nuclear Power Plant(NPP) No. 1. CCMS uses RFSP(Reactor Fueling Simulation Program) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from DCC(Digital Control Computer) for the purpose of producing basic input data. CCMS could be largely divided into two modules; CCMS server program and CCMS client program. CCMS server program plays the role in automatic and continuous RFSP run and management of the past output data resulting from the run using Data Base Management System(DBMS). CCMS client program enables users to monitor current and past core status with GUI(Graphic-User Interface) environment predefined. The effectiveness of CCMS was verified by comparing the data resulted from field-test of the system for about 43 hours with the data used in the field of Wolsong NPP No. 1.

  19. Evaluation of a multiport groundwater monitoring system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.

    1991-03-01

    In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs

  20. Data monitoring system for PV solar generators

    International Nuclear Information System (INIS)

    Stoev, M.; Katerski, A.; Williams, A.

    2000-01-01

    The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created