WorldWideScience

Sample records for monitoring stations included

  1. South Baltic representative coastal field surveys, including monitoring at the Coastal Research Station in Lubiatowo, Poland

    Science.gov (United States)

    Ostrowski, Rafał; Schönhofer, Jan; Szmytkiewicz, Piotr

    2016-10-01

    The paper contains a brief description of selected investigations carried out in the south Baltic coastal zone, with the particular focus on the history and recent activities conducted at the Coastal Research Station in Lubiatowo (CRS Lubiatowo), Poland. These activities comprise field investigations of nearshore hydrodynamic, lithodynamic, and morphodynamic processes. The study area is a sandy multi-bar shore with a mild slope, much exposed to the impact of waves approaching from NW-NE sector. The shore has a dissipative character which means that the wave energy is subject to gradual dissipation in the nearshore zone and only a small part of this energy is reflected by the shore. Due to the big wind fetch in N-NNE direction, the location of CRS Lubiatowo is favourable to registration of the maximum values of parameters of hydrodynamic and morphodynamic processes which occur in the Baltic during extreme storms.

  2. Photochemical Assessment Monitoring Stations (PAMS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Photochemical Assessment Monitoring Stations (PAMS). This file provides information on the numbers and distribution (latitude/longitude) of air monitoring sites...

  3. Air and radiation monitoring stations

    CERN Multimedia

    AUTHOR|(SzGeCERN)582709

    2015-01-01

    CERN has around 100 monitoring stations on and around its sites. New radiation measuring stations, capable of detecting even lower levels of radiation, were installed in 2014. Two members of HE-SEE group (Safety Engineering and Environment group) in front of one of the new monitoring stations.

  4. Mobile environmental radiation monitoring station

    International Nuclear Information System (INIS)

    Assido, H.; Shemesh, Y.; Mazor, T.; Tal, N.; Barak, D.

    1997-01-01

    A mobile environmental radiation monitoring station has been developed and established for the Israeli Ministry of Environment. The radiation monitoring station is ready for immediate placing in any required location, or can be operated from a vehicle. The station collects data Tom the detector and transfers it via cellular communication network to a Computerized Control Center for data storage, processing, and display . The mobile station is fully controlled from the. Routinely, the mobile station responses to the data request accumulated since the last communication session. In case of fault or alarm condition in the mobile station, a local claim is activated and immediately initiates communication with the via cellular communication network. (authors)

  5. GSFC contamination monitors for Space Station

    Science.gov (United States)

    Carosso, P. A.; Tveekrem, J. L.; Coopersmith, J. D.

    1988-01-01

    This paper describes the Work Package 3 activities in the area of neutral contamination monitoring for the Space Station. Goddard Space Flight Center's responsibilities include the development of the Attached Payload Accommodations Equipment (APAE), the Polar Orbiting Platform (POP), and the Flight Telerobotic Servicer (FTS). GSFC will also develop the Customer Servicing Facility (CSF) in Phase 2 of the Space Station.

  6. Monitoring of nuclear power stations

    International Nuclear Information System (INIS)

    Ull, E.; Labudda, H.J.

    1987-01-01

    The purpose of the invention is to create a process for undelayed automated detection and monitoring of accidents in the operation of nuclear power stations. According to the invention, this problem is solved by the relevant local measurements, such as radiation dose, components and type of radiation and additional relevant meteorological parameters being collected by means of wellknown data collection platforms, these being transmitted via transmission channels by means of satellites to suitable worldwide situated receiving stations on the ground, being processed there and being evaluated to recognise accidents. The local data collection platforms are used in the immediate vicinity of the nuclear power station. The use of aircraft, ships and balloons as data collection systems is also intended. (HWJ)

  7. ICUD-0499 Low-cost remotely sensed environmental monitoring stations

    DEFF Research Database (Denmark)

    Nielsen, Rasmus; Thorndahl, Søren Liedtke

    2017-01-01

    This study contributes with extensive research of applying low-cost remotely sensed monitoring stations to an urban environment. Design requirements are scrutinized, including applications for remote data access, hardware design, and monitoring network design. A network of 9 monitoring stations...... measuring stream water level is deployed during July 2017. Data is streamed to a web page using cellular-based data transmission. Monitoring network performance is quantified with respect to local physical and weather conditions....

  8. Atmospheric air contamination monitoring. Monitoring station ASS-500, GIG Katowice

    International Nuclear Information System (INIS)

    Michalik, B.

    1993-01-01

    The results obtained during the period of 1991-1993 in monitoring station ASS-500 working in Katowice have been presented. The concentration of 137 Cs, 226 Ra, 40 K, 7 Be and dustiness in atmospheric air have been shown. Some proposals about the modifications of monitoring station ASS-500 have been introduced. 3 figs, 5 tabs

  9. Urban Noise Recorded by Stationary Monitoring Stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir

    2017-10-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.

  10. Hawaii Munitions Monitoring Station and Natural Laboratory

    Science.gov (United States)

    Edwards, M.; Trimble, A. Z.; Rognstad, M. R.

    2017-12-01

    Hundreds of thousands of tons of conventional munitions were fired into the ocean at military ranges or deliberately disposed at sea during the twentieth century. Potential contaminants from munitions and explosives of concern (MEC) affect virtually every coast in the United States, including Alaska, the Hawaiian Islands, Guam, American Samoa and other U.S. territories as well as inland waterways. It is necessary to develop methods to assess the concentrations of munitions constituents present at a site to address concerns about the presence of environmentally relevant concentrations and their potential impacts. Having a well-characterized site to test instruments and methods is important for continued development and refinement of technology. Most sites are too big to characterize comprehensively in three dimensions over time periods lasting days or longer. We are working to develop a monitoring station and natural laboratory near Oahu, Hawaii to create a cost-effective demonstration and validation natural laboratory where emerging technologies can be evaluated and compared. Ordnance Reef (OR) is an ideal location to establish a munitions monitoring station for historical, logistical and environmental reasons. OR is an area of shallow fringing reef measuring approximately 4.2 km by 2.2 km along the Waianae coast of Oahu that was used as a disposal area for military munitions following World War II. OR has been the subject of multiple investigations including an inventory of munitions conducted by the U.S. Army Corps of Engineers in 2002 and a screening-level risk investigation conducted by the National Oceanic and Atmospheric Administration and the University of Hawaii in 2006. As a result, there are multiple datasets collected over the past fifteen years that can be leveraged to serve as a baseline for the natural laboratory. These extant datasets are being supplemented with data from integrated unmanned systems deployed at OR to characterize and visualize the

  11. Development of the Arctic radionuclide monitoring station

    International Nuclear Information System (INIS)

    King, S.E.; Phillips, G.W.; Aakenes, U.R.

    1996-01-01

    In recent years, the world has learned about the dumping of nuclear reactors and other waste into the Arctic seas by the former Soviet Union. Most of the information on the present levels of radioactivity in the region has been obtained by oceanographic expeditions conducted during the brief Arctic summers. Year-round monitoring of the movement of radio-activity during dynamic seasonal and episodic chances is hampered by the difficulties caused by sea ice, logistics and communication constraints associated with deployment and maintenance of monitoring equipment in this remote region. We have designed an autonomous station to measure the benthic gamma-ray emitting radioactivity for periods of at least one year. The station is capable of detecting a 30 Bq/m 3 increase in the 137 Cs activity in a 24 hour period. After a year-long deployment, the station releases its anchor and rises to the surface to transmit the accumulated spectra and oceanographic data via an Argos satellite link. The design and performance characteristics of the prototype station will be discussed

  12. Development of the Arctic radionuclide monitoring station

    Science.gov (United States)

    King, S. E.; Aakenes, U. R.; McCoy, K.; Phillips, G. W.

    1997-06-01

    The world has learned about the dumping of nuclear reactors and other waste into the Arctic seas by the former Soviet Union. Most of the information on the present levels of radioactivity in the region has been obtained by oceanographic expeditions conducted during the brief Arctic summers. Year-round monitoring of the movement of radioactivity during dynamic seasonal and episodic changes is hampered by the difficulties caused by sea ice, logistics and communication constraints associated with deployment and maintenance of monitoring equipment in this remote region. The authors have designed an autonomous station to measure the benthic gamma-ray emitting radioactivity for periods of at least one year. The station is capable of detecting a 30 Bq/m/sup 3/ increase in the /sup 137/Cs activity in a 24 hour period. After a year-long deployment, the station releases its anchor and rises to the surface to transmit the accumulated spectra and oceanographic data via an Argos satellite link. The design and performance characteristics of the prototype station are discussed.

  13. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  14. The central monitoring station of Indian Environmental Radiation Monitoring Network (IERMON): the architecture and functions

    International Nuclear Information System (INIS)

    Garg, Saurabh; Ratheesh, M.P.; Mukundan, T.; Patel, M.D.; Nair, C.K.G.; Puranik, V.D.

    2010-01-01

    The Indian Environmental Radiation Monitoring Network (IERMON) is being established across the country by the Bhabha Atomic Research Centre, Mumbai. The network consists of stations with automated systems for environmental radiation monitoring with online data communication facility. Currently about 100 stations are operational and additional 500 stations are expected to be installed by March, 2012. The network is established with different objectives, the main objective being the detection and reporting of any nuclear emergency anywhere in the country. The central monitoring station of the network is established in Mumbai. This paper describes the architecture and functions of IERMON Central Station. The Central Station consists of server room for online data collection from remote stations and maintenance of databases for various applications; central monitoring room for user interaction with database and IERMON website maintenance and development room for the development of new applications. The functions of IERMON Central Station include detection and reporting of nuclear emergency, maintenance of remote stations, enhancement of public awareness on environmental radiation through public display systems and website, etc. The details on system layout and data protocols can be found in the paper. (author)

  15. Pilot Water Quality Monitoring Station in Dublin Bay : North Bank Station (NBMS), MATSIS Project Part I

    OpenAIRE

    O'Donnell, Garvan; Joyce, Eileen; Silke, Joe; O'Boyle, Shane; McGovern, Evin

    2008-01-01

    This report describes the pilot development of an autonomous monitoring station in Dublin Bay and validation of the system. It presents results from initial deployments. Sensors were deployed for testing, including an optical sensor for measuring nitrate and sensors for measurement of salinity, temperature, fluorescence and dissolved oxygen. Automated water samplers enabled periodic, remote triggered and event triggered sampling for nutrient and phytoplankton samples.

  16. New Seismic Monitoring Station at Mohawk Ridge, Valles Caldera

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Peter Morse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-20

    Two new broadband digital seismic stations were installed in the Valles Caldera in 2011 and 2012. The first is located on the summit of Cerros del Abrigo (station code CDAB) and the second is located on the flanks of San Antonio Mountain (station code SAMT). Seismic monitoring stations in the caldera serve multiple purposes. These stations augment and expand the current coverage of the Los Alamos Seismic Network (LASN), which is operated to support seismic and volcanic hazards studies for LANL and northern New Mexico (Figure 1). They also provide unique continuous seismic data within the caldera that can be used for scientific studies of the caldera’s substructure and detection of very small seismic signals that may indicate changes in the current and evolving state of remnant magma that is known to exist beneath the caldera. Since the installation of CDAB and SAMT, several very small earthquakes have already been detected near San Antonio Mountain just west of SAMT (Figure 2). These are the first events to be seen in that area. Caldera stations also improve the detection and epicenter determination quality for larger local earthquakes on the Pajarito Fault System east of the Preserve and the Nacimiento Uplift to the west. These larger earthquakes are a concern to LANL Seismic Hazards assessments and seismic monitoring of the Los Alamos region, including the VCNP, is a DOE requirement. Currently the next closest seismic stations to the caldera are on Pipeline Road (PPR) just west of Los Alamos, and Peralta Ridge (PER) south of the caldera. There is no station coverage near the resurgent dome, Redondo Peak, in the center of the caldera. Filling this “hole” is the highest priority for the next new LASN station. We propose to install this station in 2018 on Mohawk Ridge just east of Redondito, in the same area already occupied by other scientific installations, such as the MCON flux tower operated by UNM.

  17. A report on upgraded seismic monitoring stations in Myanmar: Station performance and site response

    Science.gov (United States)

    Thiam, Hrin Nei; Min Htwe, Yin Myo; Kyaw, Tun Lin; Tun, Pa Pa; Min, Zaw; Htwe, Sun Hninn; Aung, Tin Myo; Lin, Kyaw Kyaw; Aung, Myat Min; De Cristofaro, Jason; Franke, Mathias; Radman, Stefan; Lepiten, Elouie; Wolin, Emily; Hough, Susan E.

    2017-01-01

    Myanmar is in a tectonically complex region between the eastern edge of the Himalayan collision zone and the northern end of the Sunda megathrust. Until recently, earthquake monitoring and research efforts have been hampered by a lack of modern instrumentation and communication infrastructure. In January 2016, a major upgrade of the Myanmar National Seismic Network (MNSN; network code MM) was undertaken to improve earthquake monitoring capability. We installed five permanent broadband and strong‐motion seismic stations and real‐time data telemetry using newly improved cellular networks. Data are telemetered to the MNSN hub in Nay Pyi Taw and archived at the Incorporated Research Institutions for Seismology Data Management Center. We analyzed station noise characteristics and site response using noise and events recorded over the first six months of station operation. Background noise characteristics vary across the array, but indicate that the new stations are performing well. MM stations recorded more than 20 earthquakes of M≥4.5 within Myanmar and its immediate surroundings, including an M 6.8 earthquake located northwest of Mandalay on 13 April 2016 and the Mw 6.8 Chauk event on 24 August 2016. We use this new dataset to calculate horizontal‐to‐vertical spectral ratios, which provide a preliminary characterization of site response of the upgraded MM stations.

  18. Seabrook Station Level 2 PRA Update to Include Accident Management

    International Nuclear Information System (INIS)

    Lutz, Robert; Lucci, Melissa; Kiper, Kenneth; Henry, Robert

    2006-01-01

    A ground-breaking study was recently completed as part of the Seabrook Level 2 PRA update. This study updates the post-core damage phenomena to be consistent with the most recent information and includes accident management activities that should be modeled in the Level 2 PRA. Overall, the result is a Level 2 PRA that fully meets the requirements of the ASME PRA Standard with respect to modeling accident management in the LERF assessment and NRC requirements in Regulatory Guide 1.174 for considering late containment failures. This technical paper deals only with the incorporation of operator actions into the Level 2 PRA based on a comprehensive study of the Seabrook Station accident response procedures and guidance. The paper describes the process used to identify the key operator actions that can influence the Level 2 PRA results and the development of success criteria for these key operator actions. This addresses a key requirement of the ASME PRA Standard for considering SAMG. An important benefit of this assessment was the identification of Seabrook specific accident management insights that can be fed back into the Seabrook Station accident management procedures and guidance or the training provided to plant personnel for these procedures and guidance. (authors)

  19. Atmosphere composition monitor for space station and advanced missions application

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Powell, F.T.

    1987-01-01

    Long-term human occupation of extraterrestrial locations may soon become a reality. The National Aeronautics and Space Administration (NASA) has recently completed the definition and preliminary design of the low earth orbit (LEO) space station. They are now currently moving into the detailed design and fabrication phase of this space station and are also beginning to analyze the requirements of several future missions that have been identified. These missions include, for example, Lunar and Mars sorties, outposts, bases, and settlements. A requirement of both the LEO space station and future missions are environmental control and life support systems (ECLSS), which provide a comfortable environment for humans to live and work. The ECLSS consists of several major systems, including atmosphere revitalization system (ARS), atmosphere pressure and composition control system, temperature and humidity control system, water reclamation system, and waste management system. Each of these major systems is broken down into subsystems, assemblies, units, and instruments. Many requirements and design drivers are different for the ECLSS of the LEO space station and the identified advanced missions (e.g., longer mission duration). This paper discusses one of the ARS assemblies, the atmosphere composition monitor assembly (ACMA), being developed for the LEO space station and addresses differences that will exist for the ACMA of future missions

  20. Status of radionuclide monitoring stations in Australia

    International Nuclear Information System (INIS)

    Burns, P.A.

    2001-01-01

    The Australian Radiation Protection and Nuclear Safety Agency (ANSTO) first became involved in the monitoring of radionuclides in the environment in 1955 when assessing the effects on the Australian population of the radioactive releases associated with the atmospheric testing of nuclear weapons. (At that time ARPANSA was known as the Commonwealth X-ray and Radium Laboratory). The United Kingdom had tested weapons in Australia in 1952 and 1953 and in August 1954 entered into an agreement with the Australian Government to establish a test range at Maralinga in South Australia. The government established a Maralinga Safety Committee and through this Committee ARPANSA became involved in the surveillance of radioactive fallout over Australia. The primary function of this surveillance was to ensure that the nuclear trials would not adversely effect the health of the Australian population. A program was established to reliably assess the deposition of radioactive fallout over Australia so that exposure to the population could be estimated. This task was performed in conjunction with the Bureau of Meteorology and the Department of Supply. Measurements were made on daily samples of fallout dawn from 10 centres throughout Australia. A low level radiochemical facility was established in 1961 for the measurement of 90 Sr and 137 Cs in environmental samples so that the long term distribution of fallout could be tracked. In the 1960s the program was extended to measure fresh fission products reaching Australia from atmospheric testing in other countries, usually originating from test sites in the northern hemisphere. The sampling program that was established was designed so that it could be rapidly expanded when a new testing program started. At this time a permanent fallout monitoring network was established around Australia using high volume air samplers capable of sampling up to 10000 m 3 per week. Approximately six stations have been operated at any one time but the

  1. Variability of road traffic noise recorded by stationary monitoring stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek

    2017-11-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads out of the town in the direction of Kraków and Warszawa. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The coefficient of variation and positional variation were proposed for performing comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes. The differences concerned the values of coefficients of variation of the equivalent sound levels.

  2. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  3. Environmental radiation monitoring system in nuclear power station

    International Nuclear Information System (INIS)

    Matsuoka, Sadazumi; Tadachi, Katsuo; Endo, Mamoru; Yuya, Hiroshi

    1983-01-01

    At the time of the construction of nuclear power stations, prior to their start of operation, the state of environmental radiation must be grasped. After the start of the power stations, based on those data, the system of environmental radiation monitoring is established. Along with the construction of Kashiwazaki-Kariwa Nuclear Power Station, The Tokyo Electric Power Co., Inc. jointly with Fujitsu Ltd. has developed a high-reliability, environmental radiation monitoring system, and adopted ''optical data highways'' using optical fiber cables for communication. It consists of a central monitoring station and 11 telemeter observation points, for collecting both radiation and meteorological data. The data sent to the central station through the highways are then outputted on a monitoring panel. They are analyzed with a central processor, and the results are printed out. (Mori, K.)

  4. Monitoring of Electromagnetic Radiation from Cellular Base Stations in Kuwait

    International Nuclear Information System (INIS)

    Al-Otaibi, A.H.; Al-Ajmi, D.; Williams, T.; McGee, D.; Dennis, J.A.; Beg, M.U.

    1998-01-01

    A survey of the radio frequency electromagnetic environment in Kuwait was carried out. The primary purpose of this survey was to monitor electromagnetic radiation (EMR) field strength levels emitted by cellular base stations installed and operated by the Kuwait Mobile Telecommunications Company (MTC). Measurements were made at 26 cellular-phone base stations, chosen as a representative sample to include 14 school sites, 2 residential sites, 2 hospital sites, 3 ministerial building sites, 3 commercial sites and 1 typical stand-alone site. On all the selected sites measurements were made with a spectrum analyser to determine the emission level in the frequency bands used by the base station transmitters (917-960 MHz). The results indicated that total field strength, specifically due to the MTC base stations, found in public access areas, varied generally between 0.05 and 1.13 V.m -1 . These values are in the order of between 40 and 800 times lower than the new pan-European CENELEC pre-standard ENV 50166-2 'Human Exposure to Electromagnetic Fields'. In terms of power density the highest observed value (0.34 μW.m -2 ) was more than a thousand times below the prescribed standards. (author)

  5. Slope Monitoring using Total Station: What are the Challenges and ...

    African Journals Online (AJOL)

    ... survey perspective on the typical problems that can be expected during slope monitoring using total station (also known as prism monitoring) and second, to suggest ways of mitigating such problems. The aim is to create awareness of the implications of incorrect use or negligence during slope monitoring surveys utilising ...

  6. Emergency protection and nuclear power station remote monitoring

    International Nuclear Information System (INIS)

    Nowak, K.; Wolf, H.

    1986-01-01

    The States of the Federal Republic of Germany are planning emergency protection measures for the environment of nuclear power stations based on their statutory duty of care. In this connection the paper explains to what extent remote monitoring of nuclear power stations practised by the Federal Supervisory Authorities may support the design and implementation of emergency protection measures. (orig.) [de

  7. Benzene monitoring at CPPI service stations

    International Nuclear Information System (INIS)

    Davis, C.S.

    1996-01-01

    A study was conducted in which ambient airborne concentration levels of benzene were measured at a representative set of gasoline service stations in Toronto and Vancouver. Benzene is considered to be toxic under the Canadian Environmental Protection Act (CEPA). It is a component in gasoline (0.1 to 4.7 per cent by volume) and is present in vehicle evaporative and exhaust emissions. Measurements were made every 18 days at each station for one year. The objective of the study was to assess the ambient and employee exposure levels of benzene at service stations and to determine whether the levels were typical of those published in the literature. In a 1986 PACE (Petroleum Association for Conservation of the Canadian Environment) survey of exposure to gasoline hydrocarbon vapours at Canadian service stations, airborne benzene concentration data was inconsistent with similar ambient and personal exposure data in the international literature. It was concluded that both the mean ambient benzene concentration and the personal exposure level measurements in this study were generally lower than similar measurements made in other countries. The same observation was made with respect to ambient and personal exposure levels measured in this study vis-a-vis those measured during the PACE study conducted in 1985/86. . 31 refs., 24 tabs., 5 figs

  8. Establishing a mobile automatic monitoring station for emergency response

    International Nuclear Information System (INIS)

    Fang, Hsin-Fa

    2008-01-01

    Full text: A radiological/nuclear emergency event may cause environmental contamination. The emergency response works always need to plan an environmental survey programme incorporating the assessment results to see what is happening. The places where are assessed to have the highest radioactive contamination/radiation dose will catch more concern and need continuous monitoring. It will cause unnecessary dangers and dose to command that personnel conduct surveying in such places when the radiological/nuclear accident become more severe. A mobile automatic monitoring station has been established for emergency response by INER (Institute of Nuclear Energy Research) to solve the problem practically. The monitoring station involves a HPIC to monitor radiation dose, an anemometer to monitor wind speed and direction, a GPS to get position data, a GPRS/3G communication module to send monitoring and positioning data to the monitoring centre where can show the monitoring result directly on a map shown on the computer. These instruments are integrated in a trailer easy to be towed to the place need to be monitored. The electric power of the station is supplied by s a solar power energy system. It can supply the station working at least 10 days without extra electric power supply designed based on the expected time length of a nuclear power plant event. The HPIC is very sensitive and stable that can discriminate a 10 nSv/hr increasing of dose rate with the monitoring time period every ten seconds. Where the radiological dispersion device events happened is not predictable, it is difficult to get suitable wind monitoring data to assess the result of radiological dispersion device events. The anemometer added on the station can provide the real time wind monitoring data to help assessment works. (author)

  9. 2. All-Polish Seminar: Monitoring of Radioactive Environment Contamination Using ASS-500 and PMS Stations

    International Nuclear Information System (INIS)

    1998-01-01

    During last 10 years the modern system of radiological pollution monitoring has been developed in Poland. At the beginning it was composed of ASS-500 stations. At the end of 1995 five automatic PMS stations have been installed as the result of the collaboration between Polish and Danish governments. Several stations of both types were include later. The system is coordinated by Central Laboratory for Radiological Protection. The report reviews the meeting dedicated to problems and future developments of the system

  10. Trends of chemical monitoring in power stations

    International Nuclear Information System (INIS)

    Winkler, R.; Venz, H.

    1983-01-01

    Frequently, the state-of-the-art of chemical monitoring in power plants is still determined by conservative methods. A thorough rationalization requires not only modern analytical procedures, but also the consideration of chemically affected processes in complex process analyses and the combination of automatic analyzers with available process computers. Using some examples, ways of reducing monitoring efforts without impairing safety and economy of nuclear power plant operation are pointed out. (author)

  11. Slope Monitoring using Total Station: What are the Challenges and ...

    African Journals Online (AJOL)

    Afeni

    implications of incorrect use or negligence during slope monitoring surveys ... Data collection, processing and the presentation of results in a concise format ..... There are several software packages on the market for total station error propagation, ..... Thomas, H.G., 2011, Slope stability prism monitoring: A guide for practising ...

  12. Low-cost automatic station for compost temperature monitoring

    Directory of Open Access Journals (Sweden)

    Marcelo D. L. Jordão

    Full Text Available ABSTRACT Temperature monitoring is an important procedure to control the composting process. Due to cost limitation, temperature monitoring is manual and with daily sampling resolution. The objective of this study was to develop an automatic station with US$ 150 dollars, able to monitor air temperature at two different points in a compost pile, with a 5-min time resolution. In the calibration test, the sensors showed an estimated uncertainty from ± 1 to ± 1.9 ºC. In the field validation test, the station guaranteed secure autonomy for seven days and endured high humidity and extreme temperature (> 70 °C.

  13. Locations of Sampling Stations for Water Quality Monitoring in Water Distribution Networks.

    Science.gov (United States)

    Rathi, Shweta; Gupta, Rajesh

    2014-04-01

    Water quality is required to be monitored in the water distribution networks (WDNs) at salient locations to assure the safe quality of water supplied to the consumers. Such monitoring stations (MSs) provide warning against any accidental contaminations. Various objectives like demand coverage, time for detection, volume of water contaminated before detection, extent of contamination, expected population affected prior to detection, detection likelihood and others, have been independently or jointly considered in determining optimal number and location of MSs in WDNs. "Demand coverage" defined as the percentage of network demand monitored by a particular monitoring station is a simple measure to locate MSs. Several methods based on formulation of coverage matrix using pre-specified coverage criteria and optimization have been suggested. Coverage criteria is defined as some minimum percentage of total flow received at the monitoring stations that passed through any upstream node included then as covered node of the monitoring station. Number of monitoring stations increases with the increase in the value of coverage criteria. Thus, the design of monitoring station becomes subjective. A simple methodology is proposed herein which priority wise iteratively selects MSs to achieve targeted demand coverage. The proposed methodology provided the same number and location of MSs for illustrative network as an optimization method did. Further, the proposed method is simple and avoids subjectivity that could arise from the consideration of coverage criteria. The application of methodology is also shown on a WDN of Dharampeth zone (Nagpur city WDN in Maharashtra, India) having 285 nodes and 367 pipes.

  14. Environmental radiation monitoring data for Point Lepreau Generating Station, 1988. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1989-01-01

    Annual report presenting a compilation of the 1988 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,700 analyses were made on 1,200 samples to monitor environmental radiation, including air filters, airborne water vapour, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops and lichen. Background radiation is measured by thermoluminescence dosimetry.

  15. Environmental radiation monitoring data for Point Lepreau Generating Station, 1987. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1988-01-01

    Annual report presenting a compilation of the 1987 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,800 analyses were made on 1,300 samples to monitor environmental radiation, including air filters, airborne water vapour, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops and periwinkles. Background radiation is measured by thermoluminescence dosimetry.

  16. Space Station Environmental Health System water quality monitoring

    Science.gov (United States)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  17. International Remote Monitoring Project Embalse Nuclear Power Station, Argentina Embalse Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, Sigfried L.; Glidewell, Donnie D.; Bonino, Anibal; Bosler, Gene; Mercer, David; Maxey, Curt; Vones, Jaromir; Martelle, Guy; Busse, James; Kadner, Steve; White, Mike; Rovere, Luis

    1999-01-01

    The Autoridad Regulatoria Nuclear of Argentina (ARN), the International Atomic Energy Agency (IAEA), ABACC, the US Department of Energy, and the US Support Program POTAS, cooperated in the development of a Remote Monitoring System for nuclear nonproliferation efforts. This system was installed at the Embalse Nuclear Power Station last year to evaluate the feasibility of using radiation sensors in monitoring the transfer of spent fuel from the spent fuel pond to dry storage. The key element in this process is to maintain continuity of knowledge throughout the entire transfer process. This project evaluated the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguard efficiency. New technology has been developed to enhance the design of the system to include storage capability on board sensor platforms. This evaluation has led to design enhancements that will assure that no data loss will occur during loss of RF transmission of the sensors

  18. Atmosphere and water quality monitoring on Space Station Freedom

    Science.gov (United States)

    Niu, William

    1990-01-01

    In Space Station Freedom air and water will be supplied in closed loop systems. The monitoring of air and water qualities will ensure the crew health for the long mission duration. The Atmosphere Composition Monitor consists of the following major instruments: (1) a single focusing mass spectrometer to monitor major air constituents and control the oxygen/nitrogen addition for the Space Station; (2) a gas chromatograph/mass spectrometer to detect trace contaminants; (3) a non-dispersive infrared spectrometer to determine carbon monoxide concentration; and (4) a laser particle counter for measuring particulates in the air. An overview of the design and development concepts for the air and water quality monitors is presented.

  19. Type of equipment in an air monitoring station

    International Nuclear Information System (INIS)

    Levy, F.

    1999-01-01

    This poster communication presents a general view of the station, the different materials used for the air and precipitations monitoring. The methods for gas measurements (tritium, krypton, iodine) are given. The collecting of dusts, dust and tritium mixed together, or rainwater and pluviometry are reviewed and the measurement of ambient radioactivity is made by beacon. (N.C.)

  20. An analysis of spatial representativeness of air temperature monitoring stations

    Science.gov (United States)

    Liu, Suhua; Su, Hongbo; Tian, Jing; Wang, Weizhen

    2018-05-01

    Surface air temperature is an essential variable for monitoring the atmosphere, and it is generally acquired at meteorological stations that can provide information about only a small area within an r m radius ( r-neighborhood) of the station, which is called the representable radius. In studies on a local scale, ground-based observations of surface air temperatures obtained from scattered stations are usually interpolated using a variety of methods without ascertaining their effectiveness. Thus, it is necessary to evaluate the spatial representativeness of ground-based observations of surface air temperature before conducting studies on a local scale. The present study used remote sensing data to estimate the spatial distribution of surface air temperature using the advection-energy balance for air temperature (ADEBAT) model. Two target stations in the study area were selected to conduct an analysis of spatial representativeness. The results showed that one station (AWS 7) had a representable radius of about 400 m with a possible error of less than 1 K, while the other station (AWS 16) had the radius of about 250 m. The representable radius was large when the heterogeneity of land cover around the station was small.

  1. Real-time trend monitoring of gas compressor stations

    Energy Technology Data Exchange (ETDEWEB)

    Van Hardeveld, T. (Nova, an Alberta Corp., AB (Canada))

    1991-02-01

    The authors' company has developed a machinery health monitoring system (MHealth) for short-term and long-term historical trending and analysis of data from its 40 gas compressor stations. The author discusses the benefits of real-time trending in troubleshooting operations, in preventative maintenance scheduling and cites specific applications in the startup operations of several new gas compressor/centrifugal compressor units.

  2. Monitoring Method and Apparatus Using Asynchronous, One-Way Transmission from Sensor to Base Station

    Science.gov (United States)

    Jensen, Scott L. (Inventor); Drouant, George J. (Inventor)

    2013-01-01

    A monitoring system is disclosed, which includes a base station and at least one sensor unit that is separate from the base station. The at least one sensor unit resides in a dormant state until it is awakened by the triggering of a vibration-sensitive switch. Once awakened, the sensor may take a measurement, and then transmit to the base station the measurement. Once data is transmitted from the sensor to the base station, the sensor may return to its dormant state. There may be various sensors for each base station and the various sensors may optionally measure different quantities, such as current, voltage, single-axis and/or three-axis magnetic fields.

  3. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    K. Sujatha

    2012-05-01

    Full Text Available Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2, excess oxygen (O2, Nitrogen dioxide (NOx, Sulphur dioxide (SOx and Carbon monoxide (CO emissions plus the flame temperature at the core of the fire ball, air/fuel ratio and the combustion quality. Higher the quality of combustion less will be the flue gases at the exhaust. The flame video was captured using an infrared camera. The flame video is then split up into the frames for further analysis. The video splitter is used for progressive extraction of the flame images from the video. The images of the flame are then pre-processed to reduce noise. The conventional classification and clustering techniques include the Euclidean distance classifier (L2 norm classifier. The intelligent classifier includes the Radial Basis Function Network (RBF, Back Propagation Algorithm (BPA and parallel architecture with RBF and BPA (PRBFBPA. The results of the validation are supported with the above mentioned performance measures whose values are in the optimal range. The values of the temperatures, combustion quality, SOx, NOx, CO, CO2 concentrations, air and fuel supplied corresponding to the images were obtained thereby indicating the necessary control action taken to increase or decrease the air supply so as to ensure complete combustion. In this work, by continuously monitoring the flame images, combustion quality was inferred (complete/partial/incomplete combustion and the air/fuel ratio can be automatically varied. Moreover in the existing set-up, measurements like NOx, CO and CO2 are inferred from the samples that are collected periodically or by

  4. Environmental radiation monitoring data for Point Lepreau Generating Station, 1990. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1991-01-01

    Annual report presenting a compilation of the 1990 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,500 analyses were made on 1,100 samples to monitor environmental radiation, including air particulates, airborne water vapour, carbon dioxide in air, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops, periwinkles, sea plants and lichen. Background radiation is measured by thermoluminescence dosimetry. Radon is not assessed.

  5. Mobile and modular. BGR develops seismological monitoring stations for universal applications

    International Nuclear Information System (INIS)

    Hinz, Erwin; Hanneken, Mark

    2016-01-01

    BGR seismologists often set up monitoring stations for testing purposes. The engineers from the Central Seismological Observatory have now developed a new type of mobile monitoring station which can be remotely controlled.

  6. Energy Management for Automatic Monitoring Stations in Arctic Regions

    Science.gov (United States)

    Pimentel, Demian

    Automatic weather monitoring stations deployed in arctic regions are usually installed in hard to reach locations. Most of the time they run unsupervised and they face severe environmental conditions: very low temperatures, ice riming, etc. It is usual practice to use a local energy source to power the equipment. There are three main ways to achieve this: (1) a generator whose fuel has to be transported to the location at regular intervals (2) a battery and (3) an energy harvesting generator that exploits a local energy source. Hybrid systems are very common. Polar nights and long winters are typical of arctic regions. Solar radiation reaching the ground during this season is very low or non-existent, depending on the geographical location. Therefore, solar power generation is not very effective. One straightforward, but expensive and inefficient solution is the use of a large bank of batteries that is recharged during sunny months and discharged during the winter. The main purpose of the monitoring stations is to collect meteorological data at regular intervals; interruptions due to a lack of electrical energy can be prevented with the use of an energy management subsystem. Keeping a balance between incoming and outgoing energy flows, while assuring the continuous operation of the station, is the delicate task of energy management strategies. This doctoral thesis explores alternate power generation solutions and intelligent energy management techniques for equipment deployed in the arctic. For instance, harvesting energy from the wind to complement solar generation is studied. Nevertheless, harvested energy is a scarce resource and needs to be used efficiently. Genetic algorithms, fuzzy logic, and common sense are used to efficiently manage energy flows within a simulated arctic weather station.

  7. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Science.gov (United States)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-09-01

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS's) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS's. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS).

  8. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-01-01

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  9. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kheliewi, Abdullah S. [National Center for Radiation Protection, King Abdulaziz City for Science and Technology, 11442 Riyadh (Saudi Arabia); Holzheimer, Clous [ENVINET GmbH, Environmental Radiation Detection, Hans-Pinsel-Straße 4, 85540 Haar (Munich) (Germany)

    2014-09-30

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  10. Personal exposure versus monitoring station data for respirable particles

    Energy Technology Data Exchange (ETDEWEB)

    Sega, K; Fugas, M

    1982-01-01

    Personal exposure to respirable particles of 12 subjects working at the same location, but living in various parts of Zagreb, was monitored for 7 consecutive days and compared with simultaneously obtained data from the outdoor network station nearest to subject's home. Although personal exposure is related to the outdoor pollution, other sources play a considerable role. Indoor exposure takes, on the average, more than 80% of the total time. The ratio between average personal exposure and respirable particle levels in the outdoor air decreases with the increased outdoor concentration (r = -0.93), indicating that this relationship might serve as a basis for a rough estimate of possible personal exposure.

  11. Monitoring and optimization of energy consumption of base transceiver stations

    International Nuclear Information System (INIS)

    Spagnuolo, Antonio; Petraglia, Antonio; Vetromile, Carmela; Formosi, Roberto; Lubritto, Carmine

    2015-01-01

    The growth and development of the mobile phone network has led to an increased demand for energy by the telecommunications sector, with a noticeable impact on the environment. Monitoring of energy consumption is a great tool for understanding how to better manage this consumption and find the best strategy to adopt in order to maximize reduction of unnecessary usage of electricity. This paper reports on a monitoring campaign performed on six BSs (Base Transceiver Stations) located central Italy, with different technology, typology and technical characteristics. The study focuses on monitoring energy consumption and environmental parameters (temperature, noise, and global radiation), linking energy consumption with the load of telephone traffic and with the air conditioning functions used to cool the transmission equipment. Moreover, using experimental data collected, it is shown, with a Monte Carlo simulation based on power saving features, how the BS monitored could save energy. - Highlights: • Energy consumption and environmental parameters of a base transceiver system have been monitored. • Energy consumption is related to the air conditioning functions and to the load of telephone traffic. • Energy saving can be obtained by careful choice of cooling parameters and by turn off BS transceivers. • Energy saving parameters can be estimated by a simulation Monte Carlo method

  12. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  13. 40 CFR 52.1080 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.1080 Section 52.1080 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1080 Photochemical Assessment Monitoring Stations (PAMS) Program. On March 24, 1994 Maryland's... Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as required by...

  14. 40 CFR 52.2426 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2426 Section 52.2426 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2426 Photochemical Assessment Monitoring Stations (PAMS) Program. On November 23, 1994 Virginia's... Photochemical Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as...

  15. Monitoring the Dead Sea Region by Multi-Parameter Stations

    Science.gov (United States)

    Mohsen, A.; Weber, M. H.; Kottmeier, C.; Asch, G.

    2015-12-01

    The Dead Sea Region is an exceptional ecosystem whose seismic activity has influenced all facets of the development, from ground water availability to human evolution. Israelis, Palestinians and Jordanians living in the Dead Sea region are exposed to severe earthquake hazard. Repeatedly large earthquakes (e.g. 1927, magnitude 6.0; (Ambraseys, 2009)) shook the whole Dead Sea region proving that earthquake hazard knows no borders and damaging seismic events can strike anytime. Combined with the high vulnerability of cities in the region and with the enormous concentration of historical values this natural hazard results in an extreme earthquake risk. Thus, an integration of earthquake parameters at all scales (size and time) and their combination with data of infrastructure are needed with the specific aim of providing a state-of-the-art seismic hazard assessment for the Dead Sea region as well as a first quantitative estimate of vulnerability and risk. A strong motivation for our research is the lack of reliable multi-parameter ground-based geophysical information on earthquakes in the Dead Sea region. The proposed set up of a number of observatories with on-line data access will enable to derive the present-day seismicity and deformation pattern in the Dead Sea region. The first multi-parameter stations were installed in Jordan, Israel and Palestine for long-time monitoring. All partners will jointly use these locations. All stations will have an open data policy, with the Deutsches GeoForschungsZentrum (GFZ, Potsdam, Germany) providing the hard and software for real-time data transmission via satellite to Germany, where all partners can access the data via standard data protocols.

  16. Welding station condition monitoring using bluetooth enabled sensors and intelligent data management

    Energy Technology Data Exchange (ETDEWEB)

    Eyers, D R; Grosvenor, R I; Prickett, P W [Intelligent Process Monitoring and Management (IPMM) Group, Cardiff School of Engineering, Cardiff University, Wales (United Kingdom)

    2005-01-01

    This paper reports on the first phase deployment of bluetooth enabled condition monitoring systems at a large multinational engineering company. The radio networking of sensor signals is a fast developing area and the facilities afforded by the Wisnet device were used in the monitoring of a welding station. This and any of the planned further monitoring systems had to comply to a carefully managed IT information plan at the company. For the example application, the development and testing of microcontoller-based pre-processing of data is reported. This includes further development of the Petri Net approach to provide event-based monitoring as a sensible alternative to the continuous transmission of the sensory data.

  17. Analysis of time series exposure rates obtained at a monitoring station around nuclear power stations

    International Nuclear Information System (INIS)

    Urabe, I.; Ogawa, Y.; Kimura, Y.; Honda, Y.; Nakashima, Y.; Yoshimoto, T.; Tsujimoto, T.

    1991-01-01

    From the investigation on the variation of AAD rates monitored in the natural environment around nuclear power station, it may be concluded; (1) Differences between monthly averaged air absorbed dose rates (AAD rates) given by all data obtained and those obtained in fine weather become larger in winter (from Dec. to Feb.) (2) Cummulative frequency distributions of AAD rates are very different among four seasons. Remarkably high AAD rates are observed by heavy rains in summer and snow falls or rains in winter. (3) Though the hypothesis that the frequency distribution of AAD rates fit to the lognormal distribution can not be accepted by chi-square test, higher part of the frequency distribution of AAD rates agree approximately with the lognormal one. (4) Identification of AAD rates due to plume exposure may be possible by statistical analysis assuming lognormal distribution of AAD rates as well as the discrimination method based on the reference standard using mean values and standard deviations of the data obtained in fine weather. (author)

  18. High-Speed Monitoring of Multiple Grid-Connected Photovoltaic Array Configurations and Supplementary Weather Station.

    Science.gov (United States)

    Boyd, Matthew T

    2017-06-01

    Three grid-connected monocrystalline silicon photovoltaic arrays have been instrumented with research-grade sensors on the Gaithersburg, MD campus of the National Institute of Standards and Technology (NIST). These arrays range from 73 kW to 271 kW and have different tilts, orientations, and configurations. Irradiance, temperature, wind, and electrical measurements at the arrays are recorded, and images are taken of the arrays to monitor shading and capture any anomalies. A weather station has also been constructed that includes research-grade instrumentation to measure all standard meteorological quantities plus additional solar irradiance spectral bands, full spectrum curves, and directional components using multiple irradiance sensor technologies. Reference photovoltaic (PV) modules are also monitored to provide comprehensive baseline measurements for the PV arrays. Images of the whole sky are captured, along with images of the instrumentation and reference modules to document any obstructions or anomalies. Nearly, all measurements at the arrays and weather station are sampled and saved every 1s, with monitoring having started on Aug. 1, 2014. This report describes the instrumentation approach used to monitor the performance of these photovoltaic systems, measure the meteorological quantities, and acquire the images for use in PV performance and weather monitoring and computer model validation.

  19. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  20. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  1. Fort Calhoun Station, Unit 1. Annual operation report: January-December 1977 (including environmental report)

    International Nuclear Information System (INIS)

    1978-02-01

    Net electrical energy generated in 1977 was 2,922,683.7 MWH with the generator on line 6,959.8 hours. Information is presented concerning operations, power generation, shutdowns, maintenance, changes, tests, experiments, occupational personnel radiation exposures, and primary coolant chemistry. Data on radioactive effluent releases, meteorology, environmental monitoring, and potential radiation doses to individuals for July 7, 1977 to December 31, 1977 are also included

  2. Design and implementation of data acquisition, communication and monitoring system for photovoltaic power station in microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Wei; Pei, Wei; Qi, Zhiping; Kong, Li [Institute of Electrical Engineering, CAS, Beijing (China)

    2008-07-01

    This paper presents the design and realization of data acquisition, communication and monitoring system for photovoltaic power station. The data acquisition module including filter algorithm and signal modulation circuit uses the digital signal processor (DSP) as the main processor, it can realize accurate real-time data acquisition; The data communication module uses Ethernet as communication network between PV system and MicroGrid. The gateway using ARM microprocessor can realize protocol conversion and bidirectional communication between CAN Bus and Ethernet; The monitoring unit with friendly human-machine interface keeps real-time performance monitoring of PV system to realize automation control. The results of experiment show that the system is practicable and effective. (orig.)

  3. Recent developments in water quality monitoring for Space Station reclaimed wastewaters

    Science.gov (United States)

    Small, John W.; Verostko, Charles E.; Linton, Arthur T.; Burchett, Ray

    1987-01-01

    This paper discusses the recent developments in water quality monitoring for Space Station reclaimed wastewaters. A preprototype unit that contains an ultraviolet absorbance organic carbon monitor integrated with pH and conductivity sensors is presented. The preprototype has provisions for automated operation and is a reagentless flow-through system without any gas/liquid interfaces. The organic carbon monitor detects by utraviolet absorbance the organic impurities in reclaimed wastewater which may be correlated to the organic carbon content of the water. A comparison of the preprototype organic carbon detection values with actual total organic carbon measurements is presented. The electrolyte double junction concept for the pH sensor and fixed electrodes for both the pH and conductivity sensors are discussed. In addition, the development of a reagentless organic carbon analyzer that incorporates ultraviolet oxidation and infrared detection is presented. Detection sensitivities, hardware development, and operation are included.

  4. Local seismic activity monitored at King Sejong Station, Antarctica

    OpenAIRE

    Lee,Duk Kee; Kim,Yea Dong; Nam,Sang Heon; Jin,Young Keun

    1998-01-01

    Source location estimation from single station earthquake data collected at King Sejong Station (62°13'3l"N, 58°47'07"W) from 1995 to 1996 provides seismic activity around King Sejong Station. Analysis of local events, less than 1.5°in angular epicentral distance, finds epicenters located near the Shackleton Fracture Zone, the South Shetland Platform, Deception Island, and North Bransfield Basin. Estimated magnitudes range from 2.2 to 4.5 on the Richter scale, averaging 4.0 in North Bransfiel...

  5. Analysis of the thermal monitoring data collected at the Peach Bottom Atomic Power Station

    International Nuclear Information System (INIS)

    Witten, A.J.; Gray, D.D.

    1977-01-01

    A comprehensive study of the data collected as part of the environmental technical specifications program for Units 2 and 3 of the Peach Bottom Atomic Power Station was conducted for the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The study included an analysis of both the hydrothermal and ecological data collected from 1967 through 1976. This paper presents the details of the hydrothermal analysis performed under this program. The two primary methods used for temperature monitoring, during both the preoperational and operational periods of the program, are a fixed thermograph network and boat survey measurements. Analysis of the boat survey data provides a fine resolution demonstrating variations in ambient temperature in Conowingo Pond, as well as providing a qualitative picture of the thermal plume produced by the Peach Bottom thermal discharge. The data from 18 thermograph stations was used for a quantitative probability analysis

  6. 13th Workshop on Radiation Monitoring for the International Space Station - Final Program

    International Nuclear Information System (INIS)

    2008-01-01

    The Workshop on Radiation Monitoring for the International Space Station (WRMISS) has been held annually since 1996. The major purpose of WRMISS is to provide a forum for discussion of technical issues concerning radiation dosimetry aboard the International Space Station. This includes discussion of new results, improved instrumentation, detector calibration, and radiation environment and transport models. The goal of WRMISS is to enhance international efforts to provide the best information on the space radiation environment in low-Earth orbit and on the exposure of astronauts and cosmonauts in order to optimize the radiation safety of the ISS crew. During the 13 th Annual WRMISS, held in the Institute of Nuclear Physics (Krakow, Poland) on 8-10 September 2008, participants presented 47 lectures

  7. Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations

    International Nuclear Information System (INIS)

    Huang Naiming; Chen Zhidong; Song Haiqing; Deng Fei; Lin Qing; Huang Nairong; Zhou Ruidong; Mo Guanghua; Li Lingjuan; Liu Ying; Li Qiaoqin; Lai Liming; Zhou Xue

    2004-01-01

    This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) 110m Ag could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m 3 , annual average of 110m Ag in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The 110m Ag concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed and cuttlefish were 2.2, 1.7 and 5.8 Bq/kg (fresh) respectively. It has significantly decreased with decreasing discharge from the stations since 1997. (3) 137 Cs could be detected in almost all seawater samples in the West Daya Bay and the concentration were relatively higher from 1994-1998. The maximum annual average was laid in 1995 and it was 4.6 Bq/m 3 . After 1999, its concentration ranged in the background level. The concentrations in other marine samples were extremely low and changed in the range of the background. (4) 3 H in seawater in the West Daya Bay would go up as a pulse soon after 3 H discharge from the station and would go down to the background after 3-5 days. The annual average of monitoring results were between 0.8-3.4 Bq/L

  8. Directory of Solar-Terrestrial Physics Monitoring Stations.

    Science.gov (United States)

    1984-09-06

    5/-- ---- I sources Toc ated.ADDRE SO , ip j NFUAkTION A0/IT STATIO N . Space Environment Services Center EATA ROU TINIL P/BLISHED N............. O N...SENT TO ARC-C---- ------ DAA oEN TOC _a-A- - - - - - - - - - - - - - - - - - -DATA ARILARLE ON REQUEST--------- YES DATA -EN To-W...FOR INFORMATIOM ABOUT STATION --- N UOSI Dept of Con e Direction d Control de Oeratio Wal Field Station de Sistemas Redioelectritcos P.O. Box S8

  9. Mobile and modular. BGR develops seismological monitoring stations for universal applications; Mobil und modular. BGR entwickelt universell einsetzbare seismologische Messstationen

    Energy Technology Data Exchange (ETDEWEB)

    Hinz, Erwin; Hanneken, Mark [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany). Fachbereich ' ' Seismologisches Zentralobservatorium, Kernwaffenteststopp' '

    2016-05-15

    BGR seismologists often set up monitoring stations for testing purposes. The engineers from the Central Seismological Observatory have now developed a new type of mobile monitoring station which can be remotely controlled.

  10. Preliminary Design of Monitoring and Control Subsystem for GNSS Ground Station

    Directory of Open Access Journals (Sweden)

    Seongkyun Jeong

    2008-06-01

    Full Text Available GNSS (Global Navigation Satellite System Ground Station monitors navigation satellite signal, analyzes navigation result, and uploads correction information to satellite. GNSS Ground Station is considered as a main object for constructing GNSS infra-structure and applied in various fields. ETRI (Electronics and Telecommunications Research Institute is developing Monitoring and Control subsystem, which is subsystem of GNSS Ground Station. Monitoring and Control subsystem acquires GPS and Galileo satellite signal and provides signal monitoring data to GNSS control center. In this paper, the configurations of GNSS Ground Station and Monitoring and Control subsystem are introduced and the preliminary design of Monitoring and Control subsystem is performed. Monitoring and Control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation solution determination module, independent quality monitoring module, and system operation and maintenance module. The design process uses UML (Unified Modeling Language method which is a standard for developing software and consists of use-case modeling, domain design, software structure design, and user interface structure design. The preliminary design of Monitoring and Control subsystem enhances operation capability of GNSS Ground Station and is used as basic material for detail design of Monitoring and Control subsystem.

  11. Proposed Construction of Boulder Seismic Station Monitoring Sites, Boulder, Wyoming. Environmental Assessment

    Science.gov (United States)

    2009-02-01

    boreholes at the Boulder Seismic Station for research, development, test, and evaluation (RDT&E) as part of the U.S. Nuclear Treaty monitoring...14 LIST OF FIGURES Figure 1. Location of the proposed Boulder Seismic Station, borehole locations and associated buffers...juncture of Spring Creek and Scab Creek Road (Figure 1). Currently, the Boulder Seismic Station has a 13-element array of seismometers on the property

  12. Monitoring the Performance of the Pedestrian Transfer Function of Train Stations Using Automatic Fare Collection Data

    NARCIS (Netherlands)

    Van den Heuvel, J.P.A.; Hoogenraad, J.H.

    2014-01-01

    Over the last years all train stations in The Netherlands have been equipped with automatic fare collection gates and/or validators. All public transport passengers use a smart card to pay their fare. In this paper we present a monitor for the performance of the pedestrian function of train stations

  13. 40 CFR 52.2035 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2035 Section 52.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Pennsylvania § 52.2035 Photochemical Assessment Monitoring Stations (PAMS) Program. On September 23, 1994... (PAMS) Program as a state implementation plan (SIP) revision, as required by section 182(c)(1) of the...

  14. Air pollution assessment in the Slovak Republic in 2005. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2006-05-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2005' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  15. Air pollution assessment in the Slovak Republic in 2004. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2005-07-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2004' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  16. Meteorological and hydrographic monitoring data collected at Dauphin Island Station in Alabama from 1999-11-06 to 2001-03-01 (NODC Accession 0122658)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Meteorological and hydrographic data were collected from a monitoring station on Dauphin Island from Nov 1999 to Feb 2001. Variables measured include air...

  17. Monitoring system including an electronic sensor platform and an interrogation transceiver

    Science.gov (United States)

    Kinzel, Robert L.; Sheets, Larry R.

    2003-09-23

    A wireless monitoring system suitable for a wide range of remote data collection applications. The system includes at least one Electronic Sensor Platform (ESP), an Interrogator Transceiver (IT) and a general purpose host computer. The ESP functions as a remote data collector from a number of digital and analog sensors located therein. The host computer provides for data logging, testing, demonstration, installation checkout, and troubleshooting of the system. The IT transmits signals from one or more ESP's to the host computer to the ESP's. The IT host computer may be powered by a common power supply, and each ESP is individually powered by a battery. This monitoring system has an extremely low power consumption which allows remote operation of the ESP for long periods; provides authenticated message traffic over a wireless network; utilizes state-of-health and tamper sensors to ensure that the ESP is secure and undamaged; has robust housing of the ESP suitable for use in radiation environments; and is low in cost. With one base station (host computer and interrogator transceiver), multiple ESP's may be controlled at a single monitoring site.

  18. Monitoring and managing component fatigue at Point Lepreau Generating Station

    International Nuclear Information System (INIS)

    Stevens, G.L.; Yetisir, M.; Scovil, A.; Slade, J.

    2008-01-01

    Many CANDU plants are now approaching the end of their design lives and are being considered for extended operation beyond their design life. The Canadian Nuclear Safety Commission (CNSC) has asked utilities to address component fatigue issues in plant life extension (PLEX) applications. In particular, environmental effects on fatigue was identified as an issue that needs to be addressed, similar to being addressed for license renewal for U.S. nuclear power plants. To address CNSC concerns, the CANDU Owners Group (COG) has initiated a program to help utilities develop component fatigue management programs for PLEX operation. A summary of a pilot study that was conducted at the Point Lepreau Generating Station (PLGS) is provided below: A plant-specific Recommendation Study provided a comprehensive review of the existing plant-specific systems, cycle counting procedures, and other fatigue-related requirements, and made some general recommendations on how best to implement a fatigue management system for PLEX. The plant-specific study determined that only 10 to 15% of the design transients have been used after 25 effective full power years (EFPY) of operation. Hence, a significant amount of original design margin for fatigue usage margin remains available for PLEX operation. Environmental fatigue considerations in heavy water (D 2 O) were included in the plant-specific assessment. Only warm-up transients were assessed to have dissolved oxygen concentrations that can result in a significant environmental effect for the ferritic steels used in the CANDU primary systems. Due to the low accumulation of transients and the absence of known thermal stratification mechanisms, thermal fatigue is not as significant an issue in CANDU plants as in pressurized water reactor (PWR) and boiling water reactor (BWR) plants. The needs for implementing a comprehensive Fatigue Management Program for PLGS to satisfy PLEX requirements were defined, and specific direction and strategy for

  19. Continuous atmospheric monitoring of the injected CO2 behavior over geological storage sites using flux stations: latest technologies and resources

    Science.gov (United States)

    Burba, George; Madsen, Rodney; Feese, Kristin

    2014-05-01

    Flux stations have been widely used to monitor emission rates of CO2 from various ecosystems for climate research for over 30 years [1]. The stations provide accurate and continuous measurements of CO2 emissions with high temporal resolution. Time scales range from 20 times per second for gas concentrations, to 15-minute, hourly, daily, and multi-year periods. The emissions are measured from the upwind area ranging from thousands of square meters to multiple square kilometers, depending on the measurement height. The stations can nearly instantaneously detect rapid changes in emissions due to weather events, as well as changes caused by variations in human-triggered events (pressure leaks, control releases, etc.). Stations can also detect any slow changes related to seasonal dynamics and human-triggered low-frequency processes (leakage diffusion, etc.). In the past, station configuration, data collection and processing were highly-customized, site-specific and greatly dependent on "school-of-thought" practiced by a particular research group. In the last 3-5 years, due to significant efforts of global and regional CO2 monitoring networks (e.g., FluxNet, Ameriflux, Carbo-Europe, ICOS, etc.) and technological developments, the flux station methodology became fairly standardized and processing protocols became quite uniform [1]. A majority of current stations compute CO2 emission rates using the eddy covariance method, one of the most direct and defensible micrometeorological techniques [1]. Presently, over 600 such flux stations are in operation in over 120 countries, using permanent and mobile towers or moving platforms (e.g., automobiles, helicopters, and airplanes). Atmospheric monitoring of emission rates using such stations is now recognized as an effective method in regulatory and industrial applications, including carbon storage [2-8]. Emerging projects utilize flux stations to continuously monitor large areas before and after the injections, to locate and

  20. Trends in Surface-Water Quality at Selected Ambient-Monitoring Network Stations in Kentucky, 1979-2004

    Science.gov (United States)

    Crain, Angela S.; Martin, Gary R.

    2009-01-01

    Increasingly complex water-management decisions require water-quality monitoring programs that provide data for multiple purposes, including trend analyses, to detect improvement or deterioration in water quality with time. Understanding surface-water-quality trends assists resource managers in identifying emerging water-quality concerns, planning remediation efforts, and evaluating the effectiveness of the remediation. This report presents the results of a study conducted by the U.S. Geological Survey, in cooperation with the Kentucky Energy and Environment Cabinet-Kentucky Division of Water, to analyze and summarize long-term water-quality trends of selected properties and water-quality constituents in selected streams in Kentucky's ambient stream water-quality monitoring network. Trends in surface-water quality for 15 properties and water-quality constituents were analyzed at 37 stations with drainage basins ranging in size from 62 to 6,431 square miles. Analyses of selected physical properties (temperature, specific conductance, pH, dissolved oxygen, hardness, and suspended solids), for major ions (chloride and sulfate), for selected metals (iron and manganese), for nutrients (total phosphorus, total nitrogen, total Kjeldahl nitrogen, nitrite plus nitrate), and for fecal coliform were compiled from the Commonwealth's ambient water-quality monitoring network. Trend analyses were completed using the S-Plus statistical software program S-Estimate Trend (S-ESTREND), which detects trends in water-quality data. The trend-detection techniques supplied by this software include the Seasonal Kendall nonparametric methods for use with uncensored data or data censored with only one reporting limit and the Tobit-regression parametric method for use with data censored with multiple reporting limits. One of these tests was selected for each property and water-quality constituent and applied to all station records so that results of the trend procedure could be compared among

  1. Research on the optimization of air quality monitoring station layout based on spatial grid statistical analysis method.

    Science.gov (United States)

    Li, Tianxin; Zhou, Xing Chen; Ikhumhen, Harrison Odion; Difei, An

    2018-05-01

    In recent years, with the significant increase in urban development, it has become necessary to optimize the current air monitoring stations to reflect the quality of air in the environment. Highlighting the spatial representation of some air monitoring stations using Beijing's regional air monitoring station data from 2012 to 2014, the monthly mean particulate matter concentration (PM10) in the region was calculated and through the IDW interpolation method and spatial grid statistical method using GIS, the spatial distribution of PM10 concentration in the whole region was deduced. The spatial distribution variation of districts in Beijing using the gridding model was performed, and through the 3-year spatial analysis, PM10 concentration data including the variation and spatial overlay (1.5 km × 1.5 km cell resolution grid), the spatial distribution result obtained showed that the total PM10 concentration frequency variation exceeded the standard. It is very important to optimize the layout of the existing air monitoring stations by combining the concentration distribution of air pollutants with the spatial region using GIS.

  2. Establishment of a Background Environmental Monitoring Station for the PNNL Campus

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Sandra F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barnett, J. Matthew [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bisping, Lynn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rishel, Jeremy P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The environmental surveillance of background levels of radionuclides and, in particular, the siting of a background environmental surveillance (monitoring) station are examined. Many published works identify and stress the need for background monitoring; however, little definitive and comprehensive information for siting a station exists. A definition of an ideal background monitoring location and the generic criteria recommended for use in establishing such a background monitoring location are proposed. There are seven primary (mandatory) criteria described with two additional, optional criteria. The criteria are applied to the Richland, Washington (WA), Pacific Northwest National Laboratory (PNNL) Campus, which currently uses background monitoring data from the nearby Hanford Site. Eleven potential background monitoring sites were identified, with one location in Benton City, WA found to meet all of the mandatory and optional criteria. It is expected that the new sampler will be installed and operating by the end of June, 2015.

  3. Vibration monitoring of large vertical pumps via a remote satellite station

    International Nuclear Information System (INIS)

    Cook, S.A.; Crowe, R.D.; Roblyer, S.P.; Toffer, H.

    1985-01-01

    The Hanford N Reactor is operated by UNC Nuclear Industries for the Department of Energy for the production of special isotopes and electric energy. The reactor has a unique design in which the equipment such as pumps, turbines, generators and diesel engines are located in separate buildings. This equipment arrangement has led to the conclusion that the most cost-effective implementation of a dedicated vibration monitoring system would be to install a computerized network system in lieu of a single analyzing station. In this approach, semi-autonomous micro processor based data collection stations referred to as satellite stations are located near each concentration of machinery to be monitored. The satellite stations provide near continuous monitoring of the machinery. They are linked to a minicomputer using voice grade telephone circuits and hardware and software specifically designed for network communications. The communications link between the satellite stations and the minicomputer permits data and programs to be transmitted between the units. This paper will describe the satellite station associated with large vertical pumps vibration monitoring. The reactor has four of these pumps to supply tertiary cooling to reactor systems. 4 figs

  4. GULF OF MEXICO SEAFLOOR STABILITY AND GAS HYDRATE MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas M. McGee; Robin C. Buchannon

    2004-11-01

    The gas hydrates research Consortium (HRC), established and administered at the University if Mississippi's Center for Marine Research and Environmental Technology (CMRET) has been active on many fronts in FY 03. Extension of the original contract through March 2004, has allowed completion of many projects that were incomplete at the end of the original project period due, primarily, to severe weather and difficulties in rescheduling test cruises. The primary objective of the Consortium, to design and emplace a remote sea floor station for the monitoring of gas hydrates in the Gulf of Mexico by the year 2005 remains intact. However, the possibility of levering HRC research off of the Joint Industries Program (JIP) became a possibility that has demanded reevaluation of some of the fundamental assumptions of the station format. These provisions are discussed in Appendix A. Landmark achievements of FY03 include: (1) Continuation of Consortium development with new researchers and additional areas of research contribution being incorporated into the project. During this period, NOAA's National Undersea Research Program's (NURP) National Institute for Undersea Science and Technology (NIUST) became a Consortium funding partner, joining DOE and Minerals Management Service (MMS); (2) Very successful annual and semiannual meetings in Oxford Mississippi in February and September, 2003; (3) Collection of piston cores from MC798 in support of the effort to evaluate the site for possible monitoring station installation; (4) Completion of the site evaluation effort including reports of all localities in the northern Gulf of Mexico where hydrates have been documented or are strongly suspected to exist on the sea floor or in the shallow subsurface; (5) Collection and preliminary evaluation of vent gases and core samples of hydrate from sites in Green Canyon and Mississippi Canyon, northern Gulf of Mexico; (6) Monitoring of gas activity on the sea floor, acoustically

  5. Masters of convenience: competition, including a rising star from Quebec, improves the service station breed

    Energy Technology Data Exchange (ETDEWEB)

    Laverty Wilson, K.

    2002-06-03

    After a decade of extensive dismantling and reconstruction, changes in the downstream refining and marketing side of the petroleum industry have progressed to the point where downstream assets are once again considered to be among the strongest and most vital parts of the industry. Merchandising has become a way of life in gasoline service stations to the point where the service station of the 21. century will likely carry mass-consumption items from panty hose to sandwiches in addition to gasoline. Petro-Canada is in the forefront of rolling out the new-image service stations, while high traffic Esso locations are adding cafes serving doughnuts, muffins, bagels, soup and sandwiches in partnership with the Tim Horton's chain. In Canada, Quebec is way ahead of the other provinces in setting the high tone in the business of catering to consumers on wheels as demonstrated by the 1,932 retail sites of 'Couche-Tard', a name synonymous with gas pumps, fresh coffee and the myriad items offered in traditional convenience stores. With a total of 1,693 stores in Canada, 239 in the United States, 13,000 plus employees and more than 800 gas pumps (80 of them branded to in-house gasoline) Couche-Tard is the ninth largest convenience retailer in North America. The article describes the rise to prominence of the Couche-Tard empire, explains why circumstances in Quebec were ripe for this type of development, and offers a glimpse into the future of the likely further development of the retail gasoline market in the rest of Canada.

  6. Operability test procedure for the TK-900 effluent monitoring station

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    This procedure will verify that the 221-B liquid effluent monitoring system, installed near the east end of the 6-in. chemical sewer header, functions as intended by design. TK-900B was installed near stairwell 3 in the 221-B electrical gallery by Project W-007H. The system is part of BAT/AKART for the BCE liquid effluent system

  7. Pilot Water Quality Monitoring Station in Dublin Bay North Bank Monitoring Station (NBMS): MATSIS Project Part I

    OpenAIRE

    O Donnell, G.; Joyce, E.; O Boyle, S.; McGovern, E.

    2008-01-01

    The lack of short-term temporal resolution associated with traditional spot sampling for monitoring water quality of dynamic coastal and estuarine waters has meant that many organisations are interesting in autonomous monitoring technologies to provide near real-time semi-continuous data. Such approaches enable capturing short term episodic events (which may be missed or alternatively skew datasets when using spot samples) and provide early warning of water quality problems. New policy driver...

  8. Radioactive aerosol detection station for near real-time atmospheric monitoring

    International Nuclear Information System (INIS)

    Mason, L.R.; Bohner, John D.

    1997-01-01

    A radionuclide aerosol detection station has been developed to measure radioactivity in the environment. The objective is to monitor the atmosphere for anthropogenic radioactivity that could be indicative of nuclear weapons tests to verify the Comprehensive Nuclear Test Ban Treaty. Eighty stations will form the backbone of the International Monitoring System in which stations are linked to a central analysis facility called the International Data Centre. Data are transmitted to this centre in near real-time to facilitate rapid detection. Principal process of the field measurement are collection, separation, and assay. Collection of airborne radioactivity is achieved through high-volume air sampling. Aerosols separation is accomplished by high-efficiency particulate filtration. Radionuclides assay is achieved by in-situ high resolution gamma spectrometry. These modules are integrated into a unit that provides power, control, and communication support subsystems. Station operation is semi-automatic requiring only minimal human interaction. (author). 6 refs., 3 figs., 3 tabs

  9. Monitoring of radioactivity in the environs of Finnish nuclear power stations in 1986

    International Nuclear Information System (INIS)

    Ilus, E.; Sjoeblom, K.L.; Aaltonen, H.; Klemola, S.; Arvela, H.

    1987-06-01

    Results of the environmental programmes monitoring radioactivity around the Finnish nuclear power stations in 1986 are reported. After the end of April the fallout nuclides from the Chernobyl accident predominated in all samples taken from the environs of the two power stations Loviisa and Olkiluoto. Radionuclides originating from the Finnish power stations were detected mainly in samples taken from the aquatic environment. The concentrations of the locally discharged nuclides were very low in comparison with the fallout nuclides and their impact on the radiation doses of the population was insignificant. Both nuclear power stations are situated in the main fallout area in Finland. The results of these large monitoring programmes give a good picture of the behaviour of the Chernobyl fallout in the specific areas in Finland

  10. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of the Mariana Archipelago since 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  11. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of the Hawaiian Archipelago since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  12. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of American Samoa in 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  13. Dynamic characteristics of background seismic noise according to records of nuclear monitoring seismic stations in Kazakstan

    International Nuclear Information System (INIS)

    Belyashova, N.N.; Sinyova, Z.I.; Komarov, I.I.; Mikhailova, N.N.

    1998-01-01

    The seismic stations of Kazakstan, included into nuclear monitoring network (see fig.1) are equipped with broad hand seismometers; seismic data are recorded in digital format. All this allows to investigate spectral and time characteristics of seismic background noise in very large frequency diapason (more than 3-5 orders), for all three components of oscillation vector. The spectral density of background seismic noise for vertical and both horizontal components (fig.2) was calculated for all of the observation points. The regular features of structure of noise spectra, inherent for all of the studied observation points, as well as some features, specific for studied places were found. The curves of spectral noise density were compared with global noise model, determined by the data of Global Seismological Network (GSN)

  14. Association between air pollution and hospital admission: Case study at three monitoring stations in Malaysia

    Science.gov (United States)

    Zahari, Marina; Zin@Ibrahim, Wan Zawiah Wan; Ismail, Noriszura; Ni, Tan Hui

    2014-06-01

    The relationships between the exposure of pollutants towards hospitalized admission and mortality have been identified in several studies on Asian cities such as Taipei, Bangkok and Tokyo. In Malaysia, evidence on the health risks associated with exposure to pollutants is limited. In this study, daily time-series data were analysed to estimate risks of cardiovascular and respiratory hospitalized admissions associated with particulate matter ≤ 10 μm (PM10), carbon monoxide (CO), nitrogen dioxide, sulphur dioxide, and ozone concentrations in Klang Valley during 2004-2009. Daily counts of hospital admissions for cardiovascular and respiratory outcomes were obtained from eleven hospitals while pollutants data were taken from several air quality monitoring stations located nearest to the hospitals. These data were fitted with Generalised Additive Poisson regression models. Additionally, temperature, humidity, and time data were also included to allow for potential effect of weather and time-varying influences on hospital admissions. CO showed the most significant (P Malaysia.

  15. The Rover Environmental Monitoring Station Ground Temperature Sensor: A Pyrometer for Measuring Ground Temperature on Mars

    Directory of Open Access Journals (Sweden)

    Miguel Ramos

    2010-10-01

    Full Text Available We describe the parameters that drive the design and modeling of the Rover Environmental Monitoring Station (REMS Ground Temperature Sensor (GTS, an instrument aboard NASA’s Mars Science Laboratory, and report preliminary test results. REMS GTS is a lightweight, low-power, and low cost pyrometer for measuring the Martian surface kinematic temperature. The sensor’s main feature is its innovative design, based on a simple mechanical structure with no moving parts. It includes an in-flight calibration system that permits sensor recalibration when sensor sensitivity has been degraded by deposition of dust over the optics. This paper provides the first results of a GTS engineering model working in a Martian-like, extreme environment.

  16. Environmental monitoring report for the Point Lepreau, New Brunswick nuclear generating station 1984

    International Nuclear Information System (INIS)

    Nelson, R.W.P.; Ellis, K.M.; Smith, J.N.

    1986-07-01

    The Point Lepreau Environmental Monitoring Program (PLEMP) has been established within the Department of Fisheries and Oceans to assess the environmental impact of radioactive, thermal, and chemical releases from the Point Lepreau, N.B. Nuclear Generating Station (NGS) located on the Bay of Fundy. This report contains the results for the second year of the operational phase of the monitoring program. Emphasis has been placed on those areas where effects from the NGS operation were expected to be observed. Further studies were carried out on the characterization of the thermal plume during several pre-arranged tritium releases. Attention was given to tritium levels at the outfall, in the atmosphere and in biological samples. An initial attempt was made to relate the distribution of tritium in the Point Lepreau area in various phases to local meteorological conditions. Radionuclide levels in lichen, including, for the first time, aerial lichen on a regular basis, an efficient accumulator of atmospheric particulates were monitored. In addition, radionuclide measurements were made on samples collected during the pre-operational phase from the major environmental reservoirs and these radioactivity levels were compared to previous measurements to assess the impact of the operation of the NGS. The purpose of this program is to provide government with a comprehensive scientific basis upon which to assess the environmental implications of the operation of nuclear reactors in coastal regions

  17. Monitoring of atmospheric 3H around Narora Atomic Power Station

    International Nuclear Information System (INIS)

    Gautam, Y.P.; Sharma, A.K.; Sharma, S.; Rao, K.S.; Kumar, J.; Kumar, V.; Singh, B.; Kumar, A.; Hedge, A.G.

    2010-01-01

    Atmospheric tritium activity is measured regularly around Narora Atomic Power Station (NAPS) since gaseous waste, which contains tritium, is being released through a 145 m high stack at NAPS site. Atmospheric data collected during 2004-2008 shows a large variation of 3 H concentration in air, fluctuating in the range of ≤0.2-91.6 Bq m -3 . Significantly, higher tritium levels were measured in samples near the site boundary (1.6 km) of NAPS compared to off-site locations. The atmospheric dilution factor was found to be in the range of 1.1 x 10 -7 -7.3 x 10 -7 s m -3 . The scavenging ratio of NAPS site was found to be varying from 0.2 x 10 4 to 14.1 x 10 4 (Bq m -3 rain water per Bq m -3 air). The inhalation dose to a member of general public at different distances (1.6-30 km) from NAPS site was found to be ranged from 0.08-0.21 μSv year -1 . (author)

  18. Spectral characteristics of seismic noise using data of Kazakhstan monitoring stations

    International Nuclear Information System (INIS)

    Mikhajlova, N.N.; Komarov, I.I.

    2006-01-01

    Spectral specifications of seismic noise research for PS23-Makanchi, Karatau, Akbulak, AS057-Borovoye and new three-component station AS059-Aktyubinsk was done. Spectral noise density models were obtained for day and night time and spectral density values variation. Noise close to low-level universal noise model is peculiar for all stations, which provides their high efficiency while seismic monitoring. Noise parameters dependence on seismic receivers installation conditions was investigated separately. Based on three stations (Makanchi, Borovoye, and Aktyubinsk), spectral density change features are shown after borehole equipment installation. (author)

  19. Comprehensive Test Ban Treaty (CTBT) monitoring station operating regime influence on radionuclide detection sensitivity

    International Nuclear Information System (INIS)

    Williams, D.L.

    1999-01-01

    International Monitoring System (IMS) stations are being deployed worldwide in support of the Comprehensive [Nuclear] Test Ban Treaty (CTBT). The highly sensitive radionuclide monitoring stations regularly sample airborne radionuclide particulates to determine whether fission products are present in the atmosphere that may be indicative of a nuclear weapons test. Standards have been set for these stations regarding their operation regime and the minimum detectable concentrations (MDCs) for specific radionuclides likely to be present after a nuclear weapons test. This study uses actual CTBT monitoring data to relate a subset of the specified operational standards with the listed MDC limits. It is determined that a relationship exists between the specified operational regime and the MDC values. Since the background radioactivity is largely a function of the radon and thoron progeny, longer decay operational regimes allow for a reduction in the background. For longer lived radionuclides, this corresponds to a reduction in MDC. (author)

  20. Identification of Homogeneous Stations for Quality Monitoring Network of Mashhad Aquifer Based on Nitrate Pollution

    Directory of Open Access Journals (Sweden)

    Moslem Akbarzadeh

    2017-01-01

    Full Text Available Introduction: For water resources monitoring, Evaluation of groundwater quality obtained via detailed analysis of pollution data. The most fundamental analysis is to identify the exact measurement of dangerous zones and homogenous station identification in terms of pollution. In case of quality evaluation, the monitoring improvement could be achieved via identifying homogenous wells in terms of pollution. Presenting a method for clustering is essential in large amounts of quality data for aquifer monitoring and quality evaluation, including identification of homogeneous stations of monitoring network and their clustering based on pollution. In this study, with the purpose of Mashhad aquifer quality evaluation, clustering have been studied based on Euclidean distance and Entropy criteria. Cluster analysis is the task of grouping a set of objects in such a way that objects in the same group (called a cluster are more similar (in some sense or another to each other than to those in other groups (clusters. SNI as a combined entropy measure for clustering calculated from dividing mutual information of two values (pollution index values to the joint entropy. These measures apply as similar distance criteria for monitoring stations clustering. Materials and Methods: First, nitrate data (as pollution index and electrical conductivity (EC (as covariate collected from the related locational situation of 287 wells in statistical period 2002 to 2011. Having identified the outlying data and estimating non-observed points by spatial-temporal Kriging method and then standardizes them, the clustering process was carried out. A similar distance of wells calculated through a clustering process based on Euclidean distance and Entropy (SNI criteria. This difference explained by characteristics such as the location of wells (longitude & latitude and the pollution index (nitrate. Having obtained a similar distance of each well to others, the hierarchical clustering

  1. Deformation integrity monitoring for GNSS positioning services including local, regional and large scale hazard monitoring - the Karlsruhe approach and software(MONIKA)

    Science.gov (United States)

    Jaeger, R.

    2007-05-01

    GNSS-positioning services like SAPOS/ascos in Germany and many others in Europe, America and worldwide, usually yield in a short time their interdisciplinary and country-wide use for precise geo-referencing, replacing traditional low order geodetic networks. So it becomes necessary that possible changes of the reference stations' coordinates are detected ad hoc. The GNSS-reference-station MONitoring by the KArlsruhe approach and software (MONIKA) are designed for that task. The developments at Karlsruhe University of Applied Sciences in cooperation with the State Survey of Baden-Württemberg are further motivated by a the official resolution of the German state survey departments' association (Arbeitsgemeinschaft der Vermessungsverwaltungen Deutschland (AdV)) 2006 on coordinate monitoring as a quality-control duty of the GNSS-positioning service provider. The presented approach can - besides the coordinate control of GNSS-positioning services - also be used to set up any GNSS-service for the tasks of an area-wide geodynamical and natural disaster-prevention service. The mathematical model of approach, which enables a multivariate and multi-epochal design approach, is based on the GNSS-observations input of the RINEX-data of the GNSS service, followed by fully automatic processing of baselines and/or session, and a near-online setting up of epoch-state vectors and their covariance-matrices in a rigorous 3D network adjustment. In case of large scale and long-term monitoring situations, geodynamical standard trends (datum-drift, plate-movements etc.) are accordingly considered and included in the mathematical model of MONIKA. The coordinate-based deformation monitoring approach, as third step of the stepwise adjustments, is based on the above epoch-state vectors, and - splitting off geodynamics trends - hereby on a multivariate and multi-epochal congruency testing. So far, that no other information exists, all points are assumed as being stable and congruent reference

  2. Designing monitoring programs for chemicals of emerging concern in potable reuse ⋯ What to include and what not to include?

    KAUST Repository

    Drewes, Jorg; Anderson, Paul D.; Denslow, Nancy D.; Olivieri, Adam W.; Schlenk, Daniel K.; Snyder, Shane A.; Maruya, Keith

    2012-01-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than '1' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound. © IWA Publishing 2013.

  3. Designing monitoring programs for chemicals of emerging concern in potable reuse--what to include and what not to include?

    Science.gov (United States)

    Drewes, J E; Anderson, P; Denslow, N; Olivieri, A; Schlenk, D; Snyder, S A; Maruya, K A

    2013-01-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than '1' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound.

  4. Designing monitoring programs for chemicals of emerging concern in potable reuse ⋯ What to include and what not to include?

    KAUST Repository

    Drewes, Jorg

    2012-11-01

    This study discussed a proposed process to prioritize chemicals for reclaimed water monitoring programs, selection of analytical methods required for their quantification, toxicological relevance of chemicals of emerging concern regarding human health, and related issues. Given that thousands of chemicals are potentially present in reclaimed water and that information about those chemicals is rapidly evolving, a transparent, science-based framework was developed to guide prioritization of which compounds of emerging concern (CECs) should be included in reclaimed water monitoring programs. The recommended framework includes four steps: (1) compile environmental concentrations (e.g., measured environmental concentration or MEC) of CECs in the source water for reuse projects; (2) develop a monitoring trigger level (MTL) for each of these compounds (or groups thereof) based on toxicological relevance; (3) compare the environmental concentration (e.g., MEC) to the MTL; CECs with a MEC/MTL ratio greater than 1 should be prioritized for monitoring, compounds with a ratio less than \\'1\\' should only be considered if they represent viable treatment process performance indicators; and (4) screen the priority list to ensure that a commercially available robust analytical method is available for that compound. © IWA Publishing 2013.

  5. CONCEPTUAL DESIGN OF MONITORING AND CONTROL SUBSYSTEM FOR GNSS GROUND STATION

    Directory of Open Access Journals (Sweden)

    Seongkyun Jeong

    2007-12-01

    Full Text Available The Global Navigation Satellite System (GNSS becomes more important and is applied to various systems. Recently, the Galileo navigation system is being developed in Europe. Also, other countries like China, Japan and India are developing the global/regional navigation satellite system. As various global/regional navigation satellite systems are used, the navigation ground system gets more important for using the navigation system reasonably and efficiently. According to this trend, the technology of GNSS Ground Station (GGS is developing in many fields. The one of purposes for this study is to develop the high precision receiver for GNSS sensor station and to provide ground infrastructure for better performance services on navigation system. In this study, we consider the configuration of GNSS Ground Station and analyze function of Monitoring and Control subsystem which is a part of GNSS Ground Station. We propose Monitoring and Control subsystem which contains the navigation software for GNSS Ground System to monitor and control equipments in GNSS Ground Station, to spread the applied field of navigation system, and to provide improved navigation information to user.

  6. The computerized management for individual monitoring data in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Lin Shumou; Yang Xiaochen

    1995-01-01

    The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE

  7. Setting up a station to monitor the background radiation

    International Nuclear Information System (INIS)

    Douglas, J.A.

    1980-12-01

    This paper gives a brief review of the sources of external background from nuclear radiations and presents methods of measurement that can be conveniently used to determine the components. The methods of calibration are considered in detail and some discussion of meteorological effects is included. (author)

  8. Technical memorandum - Aamjiwnaang First Nation community air monitoring station - results for September 2008 to August 2009

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-01-15

    In 2008, the provincial and federal governments, working with the Aamjiwnaang First Nation, established the Aamjiwnaang First Nation community air monitoring station. The station's purpose was to monitor a series of contaminants produced by local industry. In addition, through the collection and analysis of air quality information, the station provided useful input to air quality studies and community health assessments. This report presents the results from analysis of air quality information between September 1, 2008 and August 31, 2009. Overall the report finds that the local air quality is similar to that in surrounding communities during this period and there were no exceedances of any ministry standard or guideline recorded concerning the expectations for particulate matter and ozone. It will be possible in the future to use this air quality information for comparison and correlation with known point sources or modeled results.

  9. 40 CFR 52.430 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.430 Section 52.430 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Natural Resources & Environmental Control submitted a plan for the establishment and implementation of a...

  10. Radioactivity in the vicinity of Sizewell nuclear power station: marine environmental monitoring, 1983

    International Nuclear Information System (INIS)

    Hunt, G.J.

    1984-01-01

    Regular monitoring of radioactivity in the aquatic environment of the British Isles has continued. A report presents the results of this program in relation to the Sizewell nuclear power station for 1983, so as to supplement the most recently available full report which is for 1982. (author)

  11. 40 CFR 52.480 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... of Columbia's Department of Consumer and Regulatory Affairs submitted a plan for the establishment... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.480 Section 52.480 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  12. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis; Bob A. Hardage; Jeffrey Chanton; Rudy Rogers

    2006-03-01

    The Gulf of Mexico Hydrates Research Consortium was established in 1999 to assemble leaders in gas hydrates research. The group is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station has always included the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. This possibility has recently received increased attention and the group of researchers working on the station has expanded to include several microbial biologists. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments are planned for fall 2005 and center about the use of the vessel M/V Ocean Quest and its two manned submersibles. The subs will be used to effect bottom surveys, emplace sensors and sea floor experiments and make connections between sensor data loggers and the integrated data power unit (IDP). Station/observatory completion is anticipated for 2007 following the

  13. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  14. Retrofitting of an improved stack monitoring system in Rajasthan atomic power station

    International Nuclear Information System (INIS)

    Natarajan, K.

    1985-01-01

    The problems encountered in the measurement of inert gas activities, iodine activity and tritium activity released through the stack in RAPS are described and the considerations for the development of improved instruments outlined. The new approach provides for better accuracy of measurement of all the relevant radioactive parameters in the stack at one centralised place. The construction work in the station for the newly conceived stack activity monitoring system is completed and the earlier equipment used is installed in the room temporarily. Development prototypes of stack inert gas monitoring system and iodine monitoring system as described in Section 5 are made and evaluated. Fabrication of new equipment for retrofitting in RAPS is in progress and these will replace the equipment temporarily installed in the station

  15. Optimum Layout for Water Quality Monitoring Stations through Ant Colony Algorithm

    Directory of Open Access Journals (Sweden)

    Amin Afshar

    2006-09-01

    Full Text Available Due to the high cost of monitoring systems, budget limitations, and high priority given to water quality control in municipal networks, especially for unexpected events, optimum location of monitoring stations has received considerable attention during the last decade. An optimization model needs to be developed for the desirable location of monitoring stations. This research attempts to develop such a model using Ant Colony Optimization (ACO algorithm and tires to verify it through a bench-mark classical example used in previous researches. Selection of ACO as optimizer was fully justified due to discrete decision space and extensive number of binary variables in modeling system. Diversity of the policies derived from ACO may facilitate the process of decision making considering the social, physical, and economical conditions.

  16. Transformation of Air Quality Monitor Data from the International Space Station into Toxicological Effect Groups

    Science.gov (United States)

    James, John T.; Zalesak, Selina M.

    2011-01-01

    The primary reason for monitoring air quality aboard the International Space Station (ISS) is to determine whether air pollutants have collectively reached a concentration where the crew could experience adverse health effects. These effects could be near-real-time (e.g. headache, respiratory irritation) or occur late in the mission or even years later (e.g. cancer, liver toxicity). Secondary purposes for monitoring include discovery that a potentially harmful compound has leaked into the atmosphere or that air revitalization system performance has diminished. Typical ISS atmospheric trace pollutants consist of alcohols, aldehydes, aromatic compounds, halo-carbons, siloxanes, and silanols. Rarely, sulfur-containing compounds and alkanes are found at trace levels. Spacecraft Maximum Allowable Concentrations (SMACs) have been set in cooperation with a subcommittee of the National Research Council Committee on Toxicology. For each compound and time of exposure, the limiting adverse effect(s) has been identified. By factoring the analytical data from the Air Quality Monitor (AQM), which is in use as a prototype instrument aboard the ISS, through the array of compounds and SMACs, the risk of 16 specific adverse effects can be estimated. Within each adverse-effect group, we have used an additive model proportioned to each applicable 180-day SMAC to estimate risk. In the recent past this conversion has been performed using archival data, which can be delayed for months after an air sample is taken because it must be returned to earth for analysis. But with the AQM gathering in situ data each week, NASA is in a position to follow toxic-effect groups and correlate these with any reported crew symptoms. The AQM data are supplemented with data from real-time CO2 instruments aboard the ISS and from archival measurements of formaldehyde, which the AQM cannot detect.

  17. Monitoring of the operation of a nuclear power station with design problems in an importing country: The Almaraz power station

    International Nuclear Information System (INIS)

    Reig, J.

    1984-01-01

    The purpose of this paper is to describe the regulatory activities carried out in Spain as a result of the design problem occurring in the steam generators during operation of Unit I of the Almaraz nuclear power station. First, a brief introduction is given to the operating history and characteristics of Unit I of Almaraz. Particular attention is paid to the specific licences issued subsequent to commercial operation which place limitations on the operation of the station and to the operational incidents of which the Nuclear Safety Council (CSN) has been notified. Next, a description is provided of the safety evaluation carried out by the CSN. Three aspects merit particular attention: methodology, evaluation and conclusions. The methodology applied by an importing country is normally based on that of the country of origin of the design, so that the overall evaluation by the NRC has been considered sufficiently representative of aspects specific to the Almaraz power station. In this regard the importance of international collaboration is clearly seen as a principal instrument for performing the evaluation. In the evaluation a distinction is made between general and specific aspects and between inspection programmes and quality assurance requirements. In addition, the conclusions leading to the requirement of the imposition of additional limitations on the operating licence are stated. Apart from the safety evaluation carried out by the CSN, other regulatory activities have been performed over this two-year period. These activities, which include site inspections, audits of the principal supplier company, other independent calculations and so on, are described. Lastly, the paper refers to the lessons learned from the operation of the above-mentioned unit, which are immediately applicable to other Spanish nuclear power stations. (author)

  18. Hierarchical control of a photovoltaic/battery based DC microgrid including electric vehicle wireless charging station

    DEFF Research Database (Denmark)

    Xiao, Zhao xia; Fan, Haodong; Guerrero, Josep M.

    2017-01-01

    In this paper, the hierarchical control strategy of a photovoltaic/battery based dc microgrid is presented for electric vehicle (EV) wireless charging. Considering irradiance variations, battery charging/discharging requirements, wireless power transmission characteristics, and onboard battery...... coils, receiving coils and compensation capacitors, the wireless power transmission system is designed to be resonant when it is operating at the rated power, with the aim to achieve the optimum transmission system efficiency. Simulation and experimental results of the hierarchical control...... charging power change and other factors, the possible operation states are obtained. A hierarchical control strategy is established, which includes central and local controllers. The central controller is responsible for the selection and transfer of operation states and the management of the local...

  19. Performance Evaluation of wastewater treatment plant of Noosh Azar company by online monitoring station

    Directory of Open Access Journals (Sweden)

    leila haddadi

    2018-02-01

    Full Text Available Background& Objective: One of the reuses of wastewater in industries is irrigation of green space. Therefore, with proper treatment and reduction of environmental pollution of wastewater and in compliance with environmental standards, it can be used for irrigation purposes. The present study was aimed to evaluate the performance of Noosh Azar Wastewater Treatment Plant by the online monitoring station in 2016.   Materials and Methods: This descriptive cross-sectional study was performed at Noosh Azar Waste Water Treatment Plant (WWTP in Tehran. The effluent outlet parameters include COD, BOD, TSS, TOC, Turbidity, pH and temperature which were measured 12 times/day by the online monitoring station of the refinery according to the standard methods (the Examinations of Water and Wastewater, and reported at the end of each month. Data were entered into SPSS software and analyzed using statistical indices including mean and standard deviation. Results: The average total of BOD/COD ratio in the wastewater was 0.8. The results of the study showed that the average concentration of COD, BOD and TSS of the wastewater was 1624.91 ±134.85, 1310±75.38 and 283.58± 39.76 mg/L, respectively. The average of total outlet parameters of turbidity, COD, BOD, TSS and TOC were 12.78±2.21, 83.73±12.90, 41.26±6.65, 6.70±2.14, 46.03±7.08 mg/L, and pH=7.80±0.35. The total average of removal efficiencies of COD, BOD and TSS were 93.92±3.62, 96.57±1.002 and 97.57±0.936, respectively. Conclusion: Regarding the proper performance of the activated sludge system of Noosh Azar Company, the effluent  parameters such as COD, BOD, TSS, TOC, turbidity and pH, were in accordance with the standard of the Iranian Environmental Protection Agency for irrigation use. However in order to ensure the quality of the wastewater for reuse, the microbial parameters should also be considered.

  20. Surface wave site characterization at 27 locations near Boston, Massachusetts, including 2 strong-motion stations

    Science.gov (United States)

    Thompson, Eric M.; Carkin, Bradley A.; Baise, Laurie G.; Kayen, Robert E.

    2014-01-01

    The geotechnical properties of the soils in and around Boston, Massachusetts, have been extensively studied. This is partly due to the importance of the Boston Blue Clay and the extent of landfill in the Boston area. Although New England is not a region that is typically associated with seismic hazards, there have been several historical earthquakes that have caused significant ground shaking (for example, see Street and Lacroix, 1979; Ebel, 1996; Ebel, 2006). The possibility of strong ground shaking, along with heightened vulnerability from unreinforced masonry buildings, motivates further investigation of seismic hazards throughout New England. Important studies that are pertinent to seismic hazards in New England include source-parameter studies (Somerville and others, 1987; Boore and others, 2010), wave-propagation studies (Frankel, 1991; Viegas and others, 2010), empirical ground-motion prediction equations (GMPE) for computing ground-motion intensity (Tavakoli and Pezeshk, 2005; Atkinson and Boore, 2006), site-response studies (Hayles and others, 2001; Ebel and Kim, 2006), and liquefaction studies (Brankman and Baise, 2008). The shear-wave velocity (VS) profiles collected for this report are pertinent to the GMPE, site response, and liquefaction aspects of seismic hazards in the greater Boston area. Besides the application of these data for the Boston region, the data may be applicable throughout New England, through correlations with geologic units (similar to Ebel and Kim, 2006) or correlations with topographic slope (Wald and Allen, 2007), because few VS measurements are available in stable tectonic regions.Ebel and Hart (2001) used felt earthquake reports to infer amplification patterns throughout the greater Boston region and noted spatial correspondence with the dominant period and amplification factors obtained from ambient noise (horizontal-to-vertical ratios) by Kummer (1998). Britton (2003) compiled geotechnical borings in the area and produced a

  1. Monitoring and studies of environmental cumulative dose of Guangdong Da Ya Bay nuclear-power station by thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Wan Yusong; Li Shili; Yang Lin; Feng Zhanglin; Kong Lingfeng; Yu Jinglan

    1999-01-01

    The author presents the environmental γ radiation routine monitoring by TLD in Guangdong Da Ya Bay Nuclear Power Station and its peripheral 50 km area, which has been put into commercial operation since 1994. The year's monitoring result indicates that there is no obvious change of the total environmental γ radiation in Da Ya Bay Nuclear Power Station and its peripheral 50 km area. But the influence of gas release γ radiation was monitored in 1995 at the monitoring points in the area of 0∼1 km from the nuclear power station

  2. The Antarctic permafrost as a testbed for REMS (Rover Environmental Monitoring Station-Mars Science Laboratory)

    Science.gov (United States)

    Esteban, B.; Ramos, M.; Sebastián, E.; Armiens, C.; Gómez-Elvira, J.; Cabos, W.; de Pablo, M. A.

    2009-04-01

    The present climatic characteristics of Mars favor the presence of extense permafrost areas in this lonely planet. Therefore environmental parameters that are included in Martian Rover missions are also used for monitoring thermal soil surface evolution in order to study the permafrost active layer thickness and the energy balance in the soil-atmosphere boundary limit layer. The REMS (Rover Environmental Monitoring Station) is an environmental station designed by the Centro de Astrobiología (CAB- Spain) with the collaboration of national and international partners (CRISA/EADS, UPC and FMI), which is part of the payload of the MSL (Mars Science Laboratory) NASA mission to Mars (http://mars.jpl.nasa.gov/msl/overview/). This mission is expected to be launched in the final months of 2009, and mainly consists of a Rover, with a complete set of scientific instruments; the Rover will carry the biggest, most advanced suite of instruments for scientific studies ever sent to the Martian surface. Five sensors compose the REMS instrument: ground (GT-REMS) and air temperatures, wind speed and direction, pressure, humidity and ultraviolet radiation (UV-REMS). A simplified setup of the REMS was deployed on Antarctica in the surroundings of the Spanish Antarctic Stations on Livingston and Deception Islands (Maritime Antarctica), where the permafrost distribution is well-known. The aim of the experiment was to check REMS's sensors response against hard environmental conditions and calibrates their measures with standard Antarctic devices. The experimental apparatuses included some standard meteorological and thermopiles sensors corresponding to the REMS. All the sensors are mounted in a 1.8 m mast and include a Pt100 air temperature sensor with shield solar protection on the mast top, a Kipp and Zonnen CNR1 net radiometer for measuring infrared (5-50 μm) and short wave solar (305-2800 nm) radiation at 1.5 m high, GT-REMS sensor and its amplification box at 0.7 m high and finally

  3. Report on radioactive discharges and environmental monitoring at nuclear power stations during 1991

    International Nuclear Information System (INIS)

    Hurst, M.J.; Thomas, D.W.

    1992-09-01

    This report presents the details for 1991 of radioactive discharges and environmental monitoring at Nuclear Electric sites. In addition to the main section which summarises the discharges and monitoring at the Company's nuclear sites as a whole, appendices are presented covering the data in detail for individual sites. In each case the radiological impact on the general public has been estimated. Discharges generally were not substantially different from those of recent years. All radioactive effluent discharges from power stations were within authorised limits. Radiation doses to members of the public resulting from these discharges, and from direct radiation from the Stations, were in all cases less than the limit of 1 mSv per year which has been recommended by ICRP since 1985. (Author)

  4. Indicators for monitoring of safety operation and condition of nuclear power stations

    International Nuclear Information System (INIS)

    Manova, D.

    2001-01-01

    A common goal of all employees in the nuclear power field is safety operation of nuclear power stations. The evaluation and control of NPP safety operation are a part of the elements of safety management. The present report is related only to a part of the total assessment and control of the plant safety operation, namely - the indicator system for monitoring of Kozloduy NPP operation and condition. (author)

  5. Position monitor of SR beam on XAFS experimental station in BSRF

    International Nuclear Information System (INIS)

    Chen Xianneng; Xie Yaning; Hu Tiandou; Jin Yalan; Huang Daxian

    1995-01-01

    A monitor of density and position of SR (Synchrotron Radiation) beam is built on XAFS (X-ray Absorption Fine Structure) experimental station in BSRF (Beijing Synchrotron Radiation Facility). It is composed of the beam slit and its drivers, weak current amplifiers, computing amplifier for coordinate of the beam position and display with RS-232 interface. The equipment can be used for other measurement fields related with current and voltage

  6. Evaluation of the Air Quality Monitor's Performance on the International Space Station

    Science.gov (United States)

    Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara

    2010-01-01

    The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.

  7. Rapid Monitoring of Bacteria and Fungi aboard the International Space Station (ISS)

    Science.gov (United States)

    Gunter, D.; Flores, G.; Effinger, M.; Maule, J.; Wainwright, N.; Steele, A.; Damon, M.; Wells, M.; Williams, S.; Morris, H.; hide

    2009-01-01

    Microorganisms within spacecraft have traditionally been monitored with culture-based techniques. These techniques involve growth of environmental samples (cabin water, air or surfaces) on agar-type media for several days, followed by visualization of resulting colonies or return of samples to Earth for ground-based analysis. Data obtained over the past 4 decades have enhanced our understanding of the microbial ecology within space stations. However, the approach has been limited by the following factors: i) Many microorganisms (estimated > 95%) in the environment cannot grow on conventional growth media; ii) Significant time lags (3-5 days for incubation and up to several months to return samples to ground); iii) Condensation in contact slides hinders colony counting by crew; and iv) Growth of potentially harmful microorganisms, which must then be disposed of safely. This report describes the operation of a new culture-independent technique onboard the ISS for rapid analysis (within minutes) of endotoxin and beta-1, 3-glucan, found in the cell walls of gramnegative bacteria and fungi, respectively. The technique involves analysis of environmental samples with the Limulus Amebocyte Lysate (LAL) assay in a handheld device, known as the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS). LOCADPTS was launched to the ISS in December 2006, and here we present data obtained from Mach 2007 until the present day. These data include a comparative study between LOCADPTS analysis and existing culture-based methods; and an exploratory survey of surface endotoxin and beta-1, 3-glucan throughout the ISS. While a general correlation between LOCAD-PTS and traditional culture-based methods should not be expected, we will suggest new requirements for microbial monitoring based upon culture-independent parameters measured by LOCAD-PTS.

  8. A design proposal of real-time monitoring stations: implementation and performance in contrasting environmental conditions

    Directory of Open Access Journals (Sweden)

    Jose González

    2012-09-01

    Full Text Available With the aim of creating a real-time monitoring network for both oceanographic and meteorological data, a monitoring station conceptual design was developed. A common framework for software and electronics was adapted to different environmental conditions using two buoy approaches: one intended for oceanic waters, to be moored up to 30-40 m depth, where waves are the critical design factor, and one for continental waters (rivers, lakes and the inner part of estuaries, where currents are the critical design factor. When structures such as bridges are present in the area, the monitoring station can be installed on these structures, thus reducing its impact and increasing safety. In this paper, the design, implementation, operation and performance of these stations are described. A reliability index is calculated for the longest time series of the three related deployment options on the Galician coast: Cíes (oceanic buoy in front of the Ría de Vigo, Catoira (continental buoy in the Ulla river and Cortegada (installation in a bed in the Ría de Arousa.

  9. Water shortage and drought monitoring in Bačka region (Vojvodina, North Serbia: Setting-up measurement stations network

    Directory of Open Access Journals (Sweden)

    Jovanović Mlađen

    2013-01-01

    Full Text Available Water shortage and drought, as the most important hydro-climatic hazards, cause significant damages in case of most continents including SE Europe. An experimental field established in Bačka region (Vojvodina Autonomous Province, North Serbia for the purpose of droughts/water shortage monitoring and remote sensing under ongoing IPA project 'Water shortage hazard and adaptive water management strategies in the Hungarian-Serbian cross-border region' (WAHASTRAT. The main objective of this project is to determine water shortage con­flicts on a local and regional level, and to reveal the frequency, extent and severity of future hydro-cli­matic hazards. The locations of eight measurement stations selected on the principle of representativeness in term of terrain configuration and soil cover. An area in which measurement stations were placed, covers about 1000 km2 (12% of total area of Bačka and includes geomorphic units which reliable represent the relief of the whole Bačka region. Measurement stations were placed on 4 out of 5 most common soil types in the Bačka and Vojvodina: chernozem, alluvial soils, smonitza and saline and alkali soils. A measurement equipment system was constructed for the requirements of the WAHASTRAT project. The aim was to design a user-friendly and affordable IT solution, which would enable continuous re­mote monitoring of meteorological parameters and soil moisture. Independent solar-powered meas­urement stations are able to automatically measure air temperature, air humidity, wind speed, wind di­rection, precipitation and soil moisture.

  10. Improving the monitoring of quantitative conditions of peacetime fuel stocks at pumping stations

    Directory of Open Access Journals (Sweden)

    Slaviša M. Ilić

    2011-04-01

    Full Text Available The paper has solved the problem of optimizing the existing inefficient and irrational system of the quantitative monitoring of the situation in peacetime fuel supplies at the pumping stations in the Army of Serbia. A study of existing organizational forms, military pumping stations as well as civilian ones, was carried out. Based on the completion of the survey by competent persons in the military, the methods of expert evaluation and the obtained quantitative indicator of the tested models, a multicriteria optimization was performed in order to select the optimal model. The optimization of the existing models, in terms of efficiency and economy, would be the rationalization and modernization - automation of military capacity and greater reliance on automated civilian pumping stations. Introduction Within the framework of the undergoing reform of the Serbian Army and in order to reduce the total costs, it is necessary to optimize the existing supply system that is technologically outdated, inefficient and uneconomic. The problem of research in this paper is reduced to the selection of an optimal model of the quantitative monitoring of the state of peacetime stocks of fuel at the pumping stations in the Serbian Army, in order to ensure economical operation and efficient monitoring of available and issued quantities, aiming at better decision making and management in the supply system as well as at achieving faster system response, with greater reliance on government logistics. Organization of work and monitoring the fuel quantitative status at pumping stations The existing system of monitoring the quantitative state of fuel pumping stations in the Army of Serbia has the following disadvantages: getting unreliable data, due to outdated equipment for fuel handling and measuring equipment, and manual collection of data; creation of unauthorized shortages (due to subjective human error or deception; inadequate engagement of respective material and

  11. Lunar Atmosphere Probe Station: A Proof-of-Concept Instrument Package for Monitoring the Lunar Atmosphere

    Science.gov (United States)

    Lazio, J.; Jones, D. L.; MacDowall, R. J.; Stewart, K. P.; Burns, J. O.; Farrell, W. M.; Giersch, L.; O'Dwyer, I. J.; Hicks, B. C.; Polisensky, E. J.; Hartman, J. M.; Nesnas, I.; Weiler, K.; Kasper, J. C.

    2013-12-01

    The lunar exosphere is the exemplar of a plasma near the surface of an airless body. Exposed to both the solar and interstellar radiation fields, the lunar exosphere is mostly ionized, and enduring questions regarding its properties include its density and vertical extent, the extent of contributions from volatile outgassing from the Moon, and its behavior over time, including response to the solar wind and modification by landers. Relative ionospheric measurements (riometry) are based on the simple physical principle that electromagnetic waves cannot propagate through a partially or fully ionized medium below the plasma frequency, and riometers have been deployed on the Earth in numerous remote and hostile environments. A multi-frequency riometer on the lunar surface would be able to monitor, *in situ*, the vertical extent of the lunar exosphere over time. We provide an update on a concept for a riometer implemented as a secondary science payload on future lunar landers, such as those recommended in the recent Planetary Sciences Decadal Survey report or commercial ventures. The instrument concept is simple, consisting of an antenna implemented as a metal deposited on polyimide film and receiver. We illustrate various deployment mechanisms and performance of a prototype in increasing lunar analog conditions. While the prime mission of such a riometer would be probing the lunar exosphere, our concept would also be capable to measuring the properties of dust impactors. The Lunar University Network for Astrophysical Research consortium is funded by the NASA Lunar Science Institute to investigate concepts for astrophysical observatories on the Moon. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with NASA. Artist's impression of the Lunar Atmosphere Probe Station.

  12. ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

    Science.gov (United States)

    Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.; hide

    2009-01-01

    ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

  13. Mini neutron monitor measurements at the Neumayer III station and on the German research vessel Polarstern

    Science.gov (United States)

    Heber, B.; Galsdorf, D.; Herbst, K.; Gieseler, J.; Labrenz, J.; Schwerdt, C.; Walter, M.; Benadé, G.; Fuchs, R.; Krüger, H.; Moraal, H.

    2015-08-01

    Neutron monitors (NMs) are ground-based devices to measure the variation of cosmic ray intensities, and although being reliable they have two disadvantages: their size as well as their weight. As consequence, [1] suggested the development of a portable, and thus much smaller and lighter, calibration neutron monitor that can be carried to any existing station around the world [see 2; 3]. But this mini neutron monitor, moreover, can also be installed as an autonomous station at any location that provides ’’office” conditions such as a) temperatures within the range of around 0 to less than 40 degree C as well as b) internet and c) power supply. However, the best location is when the material above the NM is minimized. In 2011 a mini Neutron Monitor was installed at the Neumayer III station in Antarctica as well as the German research vessel Polarstern, providing scientific data since January 2014 and October 2012, respectively. The Polarstern, which is in the possession of the Federal Republic of Germany represented by the Ministry of Education and Research and operated by the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research and managed by the shipping company Laeisz, was specially designed for working in the polar seas and is currently one of the most sophisticated polar research vessels worldwide. It spends almost 310 days a year at sea usually being located in the waters of Antarctica between November and March while spending the northern summer months in Arctic waters. Therefore, the vessel scans the rigidity range below the atmospheric threshold and above 10 GV twice a year. In contrast to spacecraft measurements NM data are influenced by variations of the geomagnetic field as well as the atmospheric conditions. Thus, in order to interpret the data a detailed knowledge of the instrument sensitivity with geomagnetic latitude (rigidity) and atmospheric pressure is essential. In order to determine the atmospheric response data from the

  14. Mini neutron monitor measurements at the Neumayer III station and on the German research vessel Polarstern

    International Nuclear Information System (INIS)

    Heber, B; Galsdorf, D; Herbst, K; Gieseler, J; Labrenz, J; Schwerdt, C; Walter, M; Benadé, G; Fuchs, R; Krüger, H; Moraal, H

    2015-01-01

    Neutron monitors (NMs) are ground-based devices to measure the variation of cosmic ray intensities, and although being reliable they have two disadvantages: their size as well as their weight. As consequence, [1] suggested the development of a portable, and thus much smaller and lighter, calibration neutron monitor that can be carried to any existing station around the world [see 2; 3]. But this mini neutron monitor, moreover, can also be installed as an autonomous station at any location that provides ’’office” conditions such as a) temperatures within the range of around 0 to less than 40 degree C as well as b) internet and c) power supply. However, the best location is when the material above the NM is minimized. In 2011 a mini Neutron Monitor was installed at the Neumayer III station in Antarctica as well as the German research vessel Polarstern, providing scientific data since January 2014 and October 2012, respectively. The Polarstern, which is in the possession of the Federal Republic of Germany represented by the Ministry of Education and Research and operated by the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research and managed by the shipping company Laeisz, was specially designed for working in the polar seas and is currently one of the most sophisticated polar research vessels worldwide. It spends almost 310 days a year at sea usually being located in the waters of Antarctica between November and March while spending the northern summer months in Arctic waters. Therefore, the vessel scans the rigidity range below the atmospheric threshold and above 10 GV twice a year. In contrast to spacecraft measurements NM data are influenced by variations of the geomagnetic field as well as the atmospheric conditions. Thus, in order to interpret the data a detailed knowledge of the instrument sensitivity with geomagnetic latitude (rigidity) and atmospheric pressure is essential. In order to determine the atmospheric response data from the

  15. Microseismic monitoring of columnar jointed basalt fracture activity: a trial at the Baihetan Hydropower Station, China

    Science.gov (United States)

    Chen, Bing-Rui; Li, Qing-Peng; Feng, Xia-Ting; Xiao, Ya-Xun; Feng, Guang-Liang; Hu, Lian-Xing

    2014-10-01

    Severe stress release has occurred to the surrounding rocks of the typically columnar jointed basalt after excavation at the Baihetan Hydropower Station, Jinsha River, China, where cracking, collapse, and other types of failure may take place occasionally due to relaxation fracture. In order to understand the relaxation fracture characteristics of the columnar jointed basalt in the entire excavation process at the diversion tunnel of the Baihetan Hydropower Station, real-time microseismic monitoring tests were performed. First, the applicability of a geophone and accelerometer was analyzed in the columnar jointed basalt tunnel, and the results show that the accelerometer was more applicable to the cracking monitoring of the columnar jointed basalt. Next, the waveform characteristics of the microseismic signals were analyzed, and the microseismic signals were identified as follows: rock fracture signal, drilling signal, electrical signal, heavy vehicle passing signal, and blast signal. Then, the attenuation characteristics of the microseismic signals in the columnar jointed basalt tunnel were studied, as well as the types and characteristics of the columnar jointed basalt fracture. Finally, location analysis was conducted on the strong rock fracture events, in which four or more sensors were triggered, to obtain the temporal and spatial evolution characteristics and laws of the columnar jointed basalt relaxation fracture after excavation. The test results are not only of important reference value to the excavation and support of diversion tunnel at the Baihetan Hydropower Station, but also of great referential significance and value to the conduction of similar tests.

  16. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Tom McGee; Carol Lutken; Elizabeth Stidham

    2006-06-01

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort was made to locate and retain the services of a suitable vessel and submersibles or Remotely Operated Vehicles (ROVs) following the storms and the loss of the contracted vessel

  17. Geo-enviromental monitoring system of the oil storages on petrol stations

    Directory of Open Access Journals (Sweden)

    Shimenkova Anastasiya Anatol'evna

    2014-03-01

    Full Text Available In large cities, fuel consumption is growing rapidly, and therefore the number of filling stations. And they are a source of anthropogenic impact on the environment and represent current scientific and practical task, because recently no research was conducted into the optimization of monitoring systems in the construction of gas station storage tanks, and no activity on replacing the obsolete design with new storage tanks. In this regard, much attention should be paid to the creation of geo-environmental systems integrated assessment of the environment, as well as modeling and forecasting various negative situations. In the modern world, the creation of such systems is possible with the help of modern computer tools such as geographic information systems.

  18. Linking cluster analysis with synoptic meteorology to characterise chemical climates at six north-west European monitoring stations

    Energy Technology Data Exchange (ETDEWEB)

    Dorling, S.R.; Davies, T.D. [Univ. of East Anglia, Norwich (United Kingdom)

    1994-12-31

    Synoptic scale atmospheric circulation patterns are often good surrogates for the transport pathway to an individual monitoring station. Davies et al. (1990) supported this idea by showing that the chemistry of precipitation samples collected at United Kingdom monitoring stations were strongly related to the Lamb weather type index, a daily classification of the synoptic circulation influencing United Kingdom weather. Such a classification does not, however, optimise the distinction between airflow from different directions and thus over different pollution source regions.

  19. Using a noise monitoring station in a small quarry located in an urban area.

    Science.gov (United States)

    Wichers, Michiel; Iramina, Wilson Siguemasa; de Eston, Sérgio Médici; Ayres da Silva, Anna Luiza Marques

    2017-12-22

    Mining plays an important role in Brazilian exports. On the other hand, large urban centers like São Paulo, with approximately 21 million inhabitants, also demand an increasing domestic consumption of natural resources, such as construction aggregate. There are many quarries located in the surroundings of urban centers in Brazil, competing with the growth of urbanized areas. Such proximity leads to a series of conflicts involving quarries and surrounding communities, where the increase in noise levels is highlighted. Operations in quarries, in general, are intermittent. Noisier equipment, such as drilling rigs and primary crushers, operates only a few hours during the day, while other operations, such as screening and secondary and tertiary crushing, are more constant. This paper presents a study carried out in a quarry located near São Paulo, where in addition to conventional short term noise measurements at surrounding receptors, one noise monitoring station was installed, allowing to identify the noisiest moments during the quarry operating time. Through data transmitted by wireless technology, it was possible to follow the noise variations emitted from mining activities in real time and observe the noisiest events that were recorded for events that exceeded the established standards. A mobile application associated to this monitoring station facilitated the quarry's manager and employees to access immediately the monitoring information. Therefore, by using this system, it was possible to evaluate the effectiveness of noise reduction measures already taken and indicate what steps still need to be held.

  20. Development of low cost wireless radiation monitoring station using GSM network

    International Nuclear Information System (INIS)

    Nur Aira Abd Rahman; Mohd Ashhar Khalid; Nor Arymaswati Abdullah; Roslan Md Dan

    2006-01-01

    SMS or Short Message Service is a mean of GSM wireless communication that allow text messages to be sent to and from mobile cell phones. While SMS communication is mainly utilized at personal level or person to person basis; the usage of SMS can be extended into nuclear application specifically in radiation monitoring. This paper explains the development of a wireless station assembled by using a recycled Siemens M50 cell phone as substitutes to GSM modem, a PIC micro controller, and MINT-ISG home made digital survey meter at the remote transmitting site. While at the receiving end; an online monitoring system is set-up by using a Bluetooth enabled cell phone, a Bluetooth dongle, and a PC with Labview 8.0 software written as the Data logger which also served as the PC-Bluetooth interface platform. Wireless station at the remote area operates by continuously sending SMS in every 3 minutes to a predefined cellular number located at the monitoring system. The SMS consists of 6 data which individually is a survey meter readings recorded at each 30 seconds duration. At the receiver, Data logger program will retrieve the SMS from the cell phone via Bluetooth and extract the original 6 readings to be displayed on PC. The system has been successfully tested to detect and log radiation data for extended period of time. (Author)

  1. 25 years of monitoring the Waste Management Center of the Almirante Alvaro Alberto Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, O.C; Barboza, E.; Cardoso, S.N.M., E-mail: landocf@eletronuclear.gov.br, E-mail: barboza@eletronuclear.gov.br, E-mail: sergion@eletronuclear.gov.br [Eletrobras Eletronuclear S.A (ELETONUCLEAR), Paraty, RJ (Brazil). Lab. de Monitoracao Ambiental

    2013-07-01

    The goal of this paper is to present an assessment of 25 years of monitoring of the environment around the Waste Management Center (WMC) of the Almirante Alvaro Alberto Nuclear Power Station (AAANPS) since 1986 until 2011. The Environmental Monitoring Laboratory (EML) has, for purposes, to monitor the environment around the station to verify if there's a potential impact caused by the operation of the two units and to verify the dose rate levels around the waste deposits. The WMC is located in an area belonging to the AAANPS and receive solid waste of low and medium activities from Angra 1 NPP. The waste generated from Angra 2 NPP is stored inside the unit. The EML monitors the environment around the WMC to determine the environmental dose rate. The monitoring is made by direct measurement of the radiation using thermoluminescent dosimeters (TLD). Nowadays, the TLD are installed, at this time, in 6 points at the boundaries of WMC and are changed monthly. The locations of these points were already changed several times to allow the construction of new buildings. The constitution of the TLD are 4 crystals, being 3 crystals of Calcium Sulphate doped with Thulium (CaSO{sub 4}:Tm) with 3 shields and 1 crystal of Lithium Borate doped with Copper (Li{sub 2}B{sub 4}O{sub 7}:Cu) without shield. The results of the TLD measurements are normalized to a period of 30 days to compensate accidental statistical variations of the dose rates. The results, in these 25 years, show that the external area of the WMC is a supervised area, following the Norm CNEN-NN-3.01 - 'Diretrizes Basicas de Protecao Radiologica' - with access permitted only for authorized people. (author)

  2. 25 years of monitoring the Waste Management Center of the Almirante Alvaro Alberto Nuclear Power Station

    International Nuclear Information System (INIS)

    Ferreira, O.C; Barboza, E.; Cardoso, S.N.M.

    2013-01-01

    The goal of this paper is to present an assessment of 25 years of monitoring of the environment around the Waste Management Center (WMC) of the Almirante Alvaro Alberto Nuclear Power Station (AAANPS) since 1986 until 2011. The Environmental Monitoring Laboratory (EML) has, for purposes, to monitor the environment around the station to verify if there's a potential impact caused by the operation of the two units and to verify the dose rate levels around the waste deposits. The WMC is located in an area belonging to the AAANPS and receive solid waste of low and medium activities from Angra 1 NPP. The waste generated from Angra 2 NPP is stored inside the unit. The EML monitors the environment around the WMC to determine the environmental dose rate. The monitoring is made by direct measurement of the radiation using thermoluminescent dosimeters (TLD). Nowadays, the TLD are installed, at this time, in 6 points at the boundaries of WMC and are changed monthly. The locations of these points were already changed several times to allow the construction of new buildings. The constitution of the TLD are 4 crystals, being 3 crystals of Calcium Sulphate doped with Thulium (CaSO 4 :Tm) with 3 shields and 1 crystal of Lithium Borate doped with Copper (Li 2 B 4 O 7 :Cu) without shield. The results of the TLD measurements are normalized to a period of 30 days to compensate accidental statistical variations of the dose rates. The results, in these 25 years, show that the external area of the WMC is a supervised area, following the Norm CNEN-NN-3.01 - 'Diretrizes Basicas de Protecao Radiologica' - with access permitted only for authorized people. (author)

  3. On-line gamma spectroscopy measuring station for cover gas monitoring at KNK II

    International Nuclear Information System (INIS)

    Hoffmann, G.; Letz, K.D.

    1980-02-01

    An automated Ge-γ-spectrometer was developed for cover gas monitoring at KNK II which, by the gamma spectra measured, is to allow the following statements to be made on fuel cladding failure: Type, size, variation with time and subsequent development of the failure. In this report the hardware and software will be explained. Besides, an instruction manual was written for the measuring station, which allows to operate it without detailed knowledge of the manuals for the individual hardware components. (orig.) 891 HP/orig. 892 MKO [de

  4. A portable meteorological station plus nuclear radiation monitoring system using a basic-8052 micro-controller

    International Nuclear Information System (INIS)

    Al-Mohamad, A.; Aghabi, S.; Weiss, C.

    2002-01-01

    a portable meteorology station capable of measuring various atmospheric parameters (mainly ambient temperature, relative humidity, atmospheric pressure, wind speed and direction) was designed and built. The physical quantities were converted to electrical signals using suitable sensors. These signals were then processed and transferred to digital values to be stored in suitable memories. A nuclear radiation alarm system was also built, on the main board, to monitor the nuclear radiation releases levels. The system consists of three main parts: control board, data acquisition board and signals conditioning board. the overall system is controlled by a BASIC-8052 micro-controller. (authors)

  5. The replacement gag vibration monitoring system for Hinkley Point 'B' power station

    International Nuclear Information System (INIS)

    Bagwell, T.; Morrish, M.F.G.

    1985-01-01

    The original computerised system for monitoring the vibration of gags in each reactor channel of the Hinkley Point 'B' AGR Power Station did not meet the specification for a more stringent safety requirement. This paper describes the replacement of that original single processor system with an enhanced dual processor/multiple scanner computer system used to satisfy this new safety and reliability need. The specification and installation of the new hardware and software are discussed, and some of the problems encountered and their solutions are highlighted. (author)

  6. A low cost micro-station to monitor soil water potential for irrigation management

    Science.gov (United States)

    Vannutelli, Edoardo; Masseroni, Daniele; Facchi, Arianna; Gandolfi, Claudio; Renga, Filippo

    2014-05-01

    The RISPArMiA project (which stands for "reduction of water wastage through the continuous monitoring of agri-environmental parameters") won in 2013 the contest called "LINFAS - The New Ideas Make Sustainable Agriculture" and sponsored by two Italian Foundations (Fondazione Italiana Accenture and Fondazione Collegio Università Milanesi). The objective of the RISPArMiA project is to improve the irrigation efficiency at the farm scale, by providing the farmer with a valuable decision support system for the management of irrigation through the use of low-cost sensors and technologies that can easily be interfaced with Mobile devices. Through the installation of tensiometric sensors within the cropped field, the soil water potential can be continuously monitored. Using open hardware electronic platforms, a data-logger for storing the measured data will be built. Data will be then processed through a software that will allow the conversion of the monitored information into an irrigation advice. This will be notified to the farmer if the measured soil water potential exceed literature crop-specific tensiometric thresholds. Through an extrapolation conducted on the most recent monitored data, it will be also possible to obtain a simple soil water potential prevision in absence of rain events. All the information will be sent directly to a virtual server and successively on the farmer Mobile devices. Each micro-station is completely autonomous from the energy point of view, since it is powered by batteries recharged by a solar panel. The transmission modulus consists of a GSM apparatus with a SIM card. The use of free platforms (Arduino) and low cost sensors (Watermark 200SS tensiometers and soil thermocouples) will significantly reduce the costs of construction of the micro-station which are expected to be considerably lower than those required for similar instruments on the market today . Six prototype micro-stations are actually under construction. Their field testing

  7. Long open-path TDL based system for monitoring background concentration for deployment at Jungfraujoch High Altitude Research Station- Switzerland

    Science.gov (United States)

    Simeonov, Valentin; van den Bergh, Hubert; Parlange, Marc

    2010-05-01

    A new, long open-path instrument for monitoring of path-averaged methane and water vapor concentrations will be presented. The instrument is built on the monostatic scheme (transceiver - distant retroreflector). A VCSEL tunable diode laser (TDL) with a central wavelength of 1654 nm is used as a light source. A specially designed, single-cell, hollow-cube retroreflector with 150 mm aperture will be installed at 1200 m from the transceiver in the final deployment at Jungfraujjoch and 100 mm retroreflectors will be used in the other applications. The receiver is built around a 20 cm Newtonian telescope. To avoid distortions in the shape of a methane line, caused by atmospheric turbulences, the line is scanned within 1 µs. Fast InGaAs photodiodes and 200 MHz are used to achieve this scanning rate. The expected concentration resolution for the above mentioned path lengths is of the order of 2 ppb. The instrument is developed at the Swiss Federal Institute of Technology - Lausanne (EPFL) Switzerland and will be used within the GAW+ CH program for long-term monitoring of background methane concentration in the Swiss Alps. After completing the initial tests at EPFL the instrument will be installed in 2012 at the High Altitude Research Station Jungfraujoch (HARSJ) located at 3580 m ASL. The HARSJ is one of the 24 global GAW stations and carries on continuous observations of a number of trace gasses, including methane. One of the goals of the project is to compare path-averaged to ongoing point measurements of methane in order to identify possible influence of the station. Future deployments of a copy of the instrument include the Colombian part of Amazonia and Siberian wetlands.

  8. FY 1994 ambient air monitoring report for McMurdo Station, Antarctica

    International Nuclear Information System (INIS)

    Lugar, R.M.

    1994-12-01

    This report presents the results of ambient air monitoring performed during the 1994 fiscal year (FY 1994) in the vicinity of McMurdo Station, Antarctica. Routine monitoring was performed during the 1993-1994 austral summer at three locations for airborne particulate matter less than 10 micrometers (PM-10) and at two locations for carbon monoxide (CO), sulfur dioxide (SO 2 ), and nitrogen oxides (NO, NO 2 , and NO x ). Selected PM-10 filters were analyzed for arsenic, beryllium, cadmium, chromium, lead, mercury, and nickel. Additional air samples were collected at three McMurdo area locations and at Black Island for determination of the airborne concentration of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). Sampling site selection, sampling procedures, and quality assurance procedures used were consistent with US Environmental Protection Agency guidance for local ambient air quality networks

  9. The monitoring of the terrestrial environment around Almirante Alvaro Alberto nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, P.G.; Souza, R.F.; Cardoso, S.N.M., E-mail: pgtares@eletronuclear.gov.b, E-mail: rfsouza@eletronuclear.gov.b, E-mail: sergion@eletronuclear.gov.b [ELETROBRAS Eletronuclear S.A., Paraty, RJ (Brazil). Lab. de Monitoracao Ambiental

    2011-07-01

    The goal of this paper is to evaluate the environmental monitoring around Almirante Alvaro Alberto Nuclear Power Station after the beginning the operation of Unit II, in July 2000. The Environmental Monitoring Laboratory (EML) has, for purpose, to monitor the environment around the station to verify if there is a potential impact caused by the operation of the units. The EML collects several environmental samples and analyses radiometrically to determine the presence of artificial radionuclides. The types of the samples are marine samples (sea water, fish, algae, beach sand and sediments), terrestrial (milk, banana, soil, grass, superficial and underground water and river water and sediment) and aerial samples (rain water, airborne for iodine and particulate). This paper only describes the monitoring of terrestrial samples. At the EML, the samples are prepared and analysed following international procedures. The samples of milk, banana, soil, grass, surface and underground water, river water and river sediment are analysed by gamma spectrometry in a multi-channel analyser GENIE-2000 System with High-purity Germanium (HpGe) detectors to determine the activities of the detectable radionuclides. The EML also analyses tritium in surface water by liquid scintillation counting. In addition, analysis of {sup 89}Sr/{sup 90}Sr, by beta counting and {sup 131}I by gamma spectrometry are performed in the processed milk. The results are, then, compared with those obtained in pre-operational time of Angra 1 (1978 - 1982) and those obtained in operational time of the units until 2010. The results show us that, from 1982 until now, there is no impact in terrestrial environment caused by the operation neither of Angra 1 nor both Angra 1 and Angra 2. (author)

  10. The monitoring of the terrestrial environment around Almirante Alvaro Alberto nuclear power station

    International Nuclear Information System (INIS)

    Tavares, P.G.; Souza, R.F.; Cardoso, S.N.M.

    2011-01-01

    The goal of this paper is to evaluate the environmental monitoring around Almirante Alvaro Alberto Nuclear Power Station after the beginning the operation of Unit II, in July 2000. The Environmental Monitoring Laboratory (EML) has, for purpose, to monitor the environment around the station to verify if there is a potential impact caused by the operation of the units. The EML collects several environmental samples and analyses radiometrically to determine the presence of artificial radionuclides. The types of the samples are marine samples (sea water, fish, algae, beach sand and sediments), terrestrial (milk, banana, soil, grass, superficial and underground water and river water and sediment) and aerial samples (rain water, airborne for iodine and particulate). This paper only describes the monitoring of terrestrial samples. At the EML, the samples are prepared and analysed following international procedures. The samples of milk, banana, soil, grass, surface and underground water, river water and river sediment are analysed by gamma spectrometry in a multi-channel analyser GENIE-2000 System with High-purity Germanium (HpGe) detectors to determine the activities of the detectable radionuclides. The EML also analyses tritium in surface water by liquid scintillation counting. In addition, analysis of 89 Sr/ 9 0 Sr, by beta counting and 131 I by gamma spectrometry are performed in the processed milk. The results are, then, compared with those obtained in pre-operational time of Angra 1 (1978 - 1982) and those obtained in operational time of the units until 2010. The results show us that, from 1982 until now, there is no impact in terrestrial environment caused by the operation neither of Angra 1 nor both Angra 1 and Angra 2. (author)

  11. Construction of research wind-solar monitoring station 'North-East Bulgaria'

    International Nuclear Information System (INIS)

    Mateeva, Z.; Filipov, A.; Filipov, V.

    2008-01-01

    The rising energy prices, the lack of conventional energy sources, as well as the growing ecological problems, imposing the development of a new energy strategy of Bulgaria, are the prerequisites for the thorough researches in the field of wind-solar resources and the construction of experimental bases with modern equipment for the detailed investigations on the specificities of these resources with the view of their optimal utilization. The lack of homogenous covering of the territory of the country with meteorological stations, as well as the rather specific microclimatic conditions in the diverse physical-geographic localities in the country make the necessity of building experimental stations for meteo-monitoring under specific local conditions still more indispensable. This work presents the monitoring parameters of wind-solar resources in a real physical-geographic environment, for carrying out scientific-research, applied-practical and educational-training activity. A broad spectrum of scientific methods and approaches - instrumental, topographic, terrain, mathematical-statistical, numerical modeling, cartographic, educational and team-working, are envisaged for attaining the set objective. (author)

  12. Microseismic Monitoring of Strainburst Activities in Deep Tunnels at the Jinping II Hydropower Station, China

    Science.gov (United States)

    Xu, N. W.; Li, T. B.; Dai, F.; Zhang, R.; Tang, C. A.; Tang, L. X.

    2016-03-01

    Rockbursts were frequently encountered during the construction of deep tunnels at the Jinping II hydropower station, Southwest China. Investigations of the possibility of rockbursts during tunnel boring machine (TBM) and drilling and blasting (D&B) advancement are necessary to guide the construction of tunnels and to protect personnel and TBM equipment from strainburst-related accidents. A real-time, movable microseismic monitoring system was installed to forecast strainburst locations ahead of the tunnel faces. The spatiotemporal distribution evolution of microseismic events prior to and during strainbursts was recorded and analysed. The concentration of microseismic events prior to the occurrence of strainbursts was found to be a significant precursor to strainbursts in deep rock tunnelling. During a 2-year microseismic investigation of strainbursts in the deep tunnels at the Jinping II hydropower station, a total of 2240 strainburst location forecasts were issued, with 63 % correctly forecasting the locations of strainbursts. The successful forecasting of strainburst locations proved that microseismic monitoring is essential for the assessment and mitigation of strainburst hazards, and can be used to minimise damage to equipment and personnel. The results of the current study may be valuable for the construction management and safety assessment of similar underground rock structures under high in situ stress.

  13. Metropolitan garbage dumps: possible winter migratory raptor monitoring stations in peninsular India

    Directory of Open Access Journals (Sweden)

    S. Pande

    2010-09-01

    Full Text Available Winter raptor migration and movement is poorly documented for peninsular India, mainly due to the lack of geographical bottlenecks. We describe, for the first time, the use of a garbage dump in a metropolitan city as an alternative visual winter raptor monitoring station. The daily count, adult to juvenile ratios and species composition of three migratory raptor species, Steppe Eagle Aquila nipalensis, Black-eared Kite Milvus migrans lineatus and Tawny Eagle Aquila rapax are presented. Ground temperatures at the garbage dump site and surrounding area, and the wing beat rate of migratory raptors before and after arrival in the early morning were measured. A total of 355 raptors migrating over a period of six observation days with 250 adults and 105 juveniles were recorded. The temperature of the garbage dump was significantly higher than the surrounding area, while the wing flapping rate was significantly lower over the garbage dump area. It is possible that migrating raptors use garbage dump thermals in the early morning to save energy with soaring and gliding flight (versus flapping flight. We propose that such sites may be used as visual winter migration monitoring stations in metropolitan cities in peninsular India.

  14. Project of a Near-Real-Time Sismo-acoustic Submarine Station for offshore monitoring (NRTSSS)

    Science.gov (United States)

    D'Anna, G.; Calore, D.; Mangano, G.; D'Alessandro, A.; Favali, P.

    2011-12-01

    The INGV seismic network ensures reliable and continuous monitoring of the Italian territory. However, the peculiarity of the Italian peninsula, characterised by an intense offshore geodynamic and seismic activity, requires the extension of the seismic monitoring to the sea. The aim of this project is: - to identify bottleneck is related to the construction, installation and use of underwater seismic station; - to define the most appropriate and low-cost architecture to guarantee the minimum functionality required for a seismic station. In order to obtain reliable seafloor seismic signals integrated to land-based network, the requirements to be fulfill are: - an acceptable coupling with the seabed; - the orientation of the components with respect to the magnetic North and to the verticality; - the correct time stamp of the data; - the data transfer to the land for the integration. Currently, the optimal solution for offshore seismic station is a cable connection to power and real-time data transfer, like the case of Western Ionian Sea cabled observatory, one of the operative node of the EMSO research infrastructure (European Multidisciplinary Seafloor and water column Observatory, http://emso-eu.org). But in the Mediterranean many seismic areas are located a few tens-hundreds of miles from the coast and cabled solutions are not feasible essentially for economic reasons. For this kind of installations EMSO research infrastructure foresees no-cabled solution, that requires a surface buoy deployed in the vicinity seafloor modules.This project plans to develop a surface buoy equipped with autonomous power supply system to power also the seafloor platforms and two-way communication system enabling the data transfer through latest generation of broadband radio communication or satellite link (Fig. 1). All the components of the prototype system are described.

  15. Radiation monitoring using manned helicopter around the nuclear power station in the fiscal year 2015 (Contract research)

    International Nuclear Information System (INIS)

    Sanada, Yukihisa; Munakata, Masahiro; Mori, Airi; Ishizaki, Azusa; Shimada, Kazumasa; Hirouchi, Jun; Urabe, Yoshimi; Nakanishi, Chika; Yamada, Tsutomu; Iwai, Takeyuki; Matsunaga, Yuki; Toyoda, Masayuki; Tobita, Shinichiro; Nishizawa, Yukiyasu; Ishida, Mutsushi; Sato, Yoshiharu; Sasaki, Miyuki; Hirayama, Hirokatsu; Takamura, Yoshihide; Nishihara, Katsuya; Imura, Mitsuo; Miyamoto, Kenji; Kudo, Tamotsu; Nakayama, Shinichi

    2016-10-01

    By the nuclear disaster of Fukushima Daiichi Nuclear Power Station (FDNPS), Tokyo Electric Power Company (TEPCO), caused by the East Japan earthquake and the following tsunami occurred on March 11, 2011, a large amount of radioactive materials was released from the NPS. After the nuclear disaster, airborne radiation monitoring using manned helicopter was conducted around FDNPS. In addition, background dose rate monitoring was conducted around the Sendai Nuclear Power Station. These results of the aerial radiation monitoring using the manned helicopter in the fiscal 2015 were summarized in the report. In addition, we developed the discrimination technique of the Rn-progenies and the evaluation of radiation attenuation by snow. (author)

  16. Monitoring equipment environment during nuclear plant operation at Salem and Hope Creek generating stations

    International Nuclear Information System (INIS)

    Blum, A.; Smith, R.J.

    1991-01-01

    Monitoring of environmental parameters has become a significant issue for operating nuclear power plants. While the long-term benefits of plant life extension programs are being pursued with comprehensive environmental monitoring programs, the potential effect of local hot spots at various plant locations needs to be evaluated for its effect on equipment degradation and shortening of equipment qualified life. A significant benefit can be experienced from temperature monitoring when a margin exists between the design versus actual operating temperature. This margin can be translated into longer equipment qualified life and significant reduction in maintenance activities. At PSE and G, the immediate need for monitoring environmental parameters is being accomplished via the use of a Logic Beach Bitlogger. The Bitlogger is a portable data loggings system consisting of a system base, input modules and a communication software package. Thermocouples are installed on selected electrical equipment and cables are run from the thermocouples to the input module of the Bitlogger. Temperature readings are taken at selected intervals, stored in memory, and downloaded periodically to a PC software program, i.e., Lotus. The data is formatted into tabular or graphical documents. Because of their versatility, Bitloggers are being used differently at the authors Nuclear facility. At the Salem Station (2 Units-4 loop Westinghouse PWR), a battery powered, fully portable, calibrated Bitlogger is located in an accessible area inside Containment where it monitors the temperature of various electrical equipment within the Pressurizer Enclosure. It is planned that close monitoring of the local hot spot temperatures in this area will allow them to adjust and reconcile the environmental qualification of the equipment

  17. Setup and Calibration of SLAC's Peripheral Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, C.

    2004-09-03

    The goals of this project were to troubleshoot, repair, calibrate, and establish documentation regarding SLAC's (Stanford Linear Accelerator Center's) PMS (Peripheral Monitoring Station) system. The PMS system consists of seven PMSs that continuously monitor skyshine (neutron and photon) radiation levels in SLAC's environment. Each PMS consists of a boron trifluoride (BF{sub 3}) neutron detector (model RS-P1-0802-104 or NW-G-20-12) and a Geiger Moeller (GM) gamma ray detector (model TGM N107 or LND 719) together with their respective electronics. Electronics for each detector are housed in Nuclear Instrument Modules (NIMs) and are plugged into a NIM bin in the station. All communication lines from the stations to the Main Control Center (MCC) were tested prior to troubleshooting. To test communication with MCC, a pulse generator (Systron Donner model 100C) was connected to each channel in the PMS and data at MCC was checked for consistency. If MCC displayed no data, the communication cables to MCC or the CAMAC (Computer Automated Measurement and Control) crates were in need of repair. If MCC did display data, then it was known that the communication lines were intact. All electronics from each station were brought into the lab for troubleshooting. Troubleshooting usually consisted of connecting an oscilloscope or scaler (Ortec model 871 or 775) at different points in the circuit of each detector to record simulated pulses produced by a pulse generator; the input and output pulses were compared to establish the location of any problems in the circuit. Once any problems were isolated, repairs were done accordingly. The detectors and electronics were then calibrated in the field using radioactive sources. Calibration is a process that determines the response of the detector. Detector response is defined as the ratio of the number of counts per minute interpreted by the detector to the amount of dose equivalent rate (in mrem per hour, either calculated

  18. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas M. McGee; Carol Blanton Lutken; Elizabeth Stidham

    2007-03-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 (MC118) in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. These delays caused scheduling and deployments difficulties but many

  19. Global Monitoring of Mountain Glaciers Using High-Resolution Spotlight Imaging from the International Space Station

    Science.gov (United States)

    Donnellan, A.; Green, J. J.; Bills, B. G.; Goguen, J.; Ansar, A.; Knight, R. L.; Hallet, B.; Scambos, T. A.; Thompson, L. G.; Morin, P. J.

    2013-12-01

    Mountain glaciers around the world are retreating rapidly, contributing about 20% to present-day sea level rise. Numerous studies have shown that mountain glaciers are sensitive to global environmental change. Temperate-latitude glaciers and snowpack provide water for over 1 billion people. Glaciers are a resource for irrigation and hydroelectric power, but also pose flood and avalanche hazards. Accurate mass balance assessments have been made for only 280 glaciers, yet there are over 130,000 in the World Glacier Inventory. The rate of glacier retreat or advance can be highly variable, is poorly sampled, and inadequately understood. Liquid water from ice front lakes, rain, melt, or sea water and debris from rocks, dust, or pollution interact with glacier ice often leading to an amplification of warming and further melting. Many mountain glaciers undergo rapid and episodic events that greatly change their mass balance or extent but are sparsely documented. Events include calving, outburst floods, opening of crevasses, or iceberg motion. Spaceborne high-resolution spotlight optical imaging provides a means of clarifying the relationship between the health of mountain glaciers and global environmental change. Digital elevation models (DEMs) can be constructed from a series of images from a range of perspectives collected by staring at a target during a satellite overpass. It is possible to collect imagery for 1800 targets per month in the ×56° latitude range, construct high-resolution DEMs, and monitor changes in high detail over time with a high-resolution optical telescope mounted on the International Space Station (ISS). Snow and ice type, age, and maturity can be inferred from different color bands as well as distribution of liquid water. Texture, roughness, albedo, and debris distribution can be estimated by measuring bidirectional reflectance distribution functions (BRDF) and reflectance intensity as a function of viewing angle. The non-sun-synchronous orbit

  20. Experience with the TUeV pipe monitoring system at the Grohnde nuclear power station

    International Nuclear Information System (INIS)

    Dittmar, H.; Hofstoetter, P.

    1995-01-01

    A special pipe monitoring system has been developed by TUeV Rheinland during the construction, commissioning and operation of the Grohnde nuclear power station. On the basis of measurements during construction and commissioning a basic monitoring system has been developed, using not only a system of sophisticated sensors that had been permanently installed from the beginning but also a large number of quite simple additional sensors. Measurements were taken before, during and after inspections and led to the discovery of unexpected and high stresses during service as well as to long-term changes over a period of years.Special measurements were taken with high temperature strain gauges and thermocouples to identify problems such as temperature layering. A special on-line measuring device was developed and used for the continuous monitoring of temperatures during operation.All these measurements help to identify out areas with high stresses or service conditions giving rise to high loads, in order on the one hand to prevent damage and on the other hand to prove that the pipes are functioning within their design parameters without problems. ((orig.))

  1. Monitoring the Microgravity Environment Quality On-Board the International Space Station Using Soft Computing Techniques

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.

    2001-01-01

    This paper presents an artificial intelligence monitoring system developed by the NASA Glenn Principal Investigator Microgravity Services project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment in time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a graphical display, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, platform structural modes, etc., and decide whether or not to run their experiments based on the acceleration environment associated with a specific event. This monitoring system is focused primarily on detecting the vibratory disturbance sources, but could be used as well to detect some of the transient disturbance sources, depending on the events duration. The system has built-in capability to detect both known and unknown vibratory disturbance sources. Several soft computing techniques such as Kohonen's Self-Organizing Feature Map, Learning Vector Quantization, Back-Propagation Neural Networks, and Fuzzy Logic were used to design the system.

  2. The JPL Electronic Nose: Monitoring Air in the US Lab on the International Space Station

    Science.gov (United States)

    Ryan, M. A.; Manatt, K. S.; Gluck, S.; Shevade, A. V.; Kisor, A. K.; Zhou, H.; Lara, L. M.; Homer, M. L.

    2010-01-01

    An electronic nose with a sensor array of 32 conductometric sensors has been developed at the Jet Propulsion Laboratory (JPL) to monitor breathing air in spacecraft habitat. The Third Generation ENose is designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 oC, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The monitoring targets are anomalous events such as leaks and spills of solvents, coolants or other fluids. The JPL ENose operated as a technology demonstration for seven months in the U.S. Laboratory Destiny during 2008-2009. Analysis of ENose monitoring data shows that there was regular, periodic rise and fall of humidity and occasional releases of Freon 218 (perfluoropropane), formaldehyde, methanol and ethanol. There were also several events of unknown origin, half of them from the same source. Each event lasted from 20 to 100 minutes, consistent with the air replacement time in the US Lab.

  3. The development of on-line thermal performance monitors in Nuclear Electric Company's stations

    International Nuclear Information System (INIS)

    Conner, A.S.

    1992-01-01

    The paper examines the economic benefits of using on-line monitoring techniques in assisting Station Staff with the task of optimising the efficient use of reactor fuel. The role of thermal performance monitoring for detecting changes in plant condition is also examined and the way in which the data can be used by engineers to assist with the preparation of operating and maintenance programmes. To enable genuine gradual changes in plant performance to be detected when operating against a background of changing plant signal accuracy conditions, plant transducers have to be calibrated on a regular basis. This can be both costly and labour intensive. To reduce this requirement for regular calibrations, an automatic software signal verification program has been developed for use in on-line monitoring schemes. It forms part of the total unit performance calculation package and uses a whole plant model to verify plant signals. All plant signals used to calculate unit heat rate are verified typically every 15 minutes with signals going outside predetermined limits being automatically reported to the user. The program is interactive allowing the user to interrogate the condition of the signal, with respect to both its error magnitude and rate of drift outside signal limits. The program runs in real time mode on a Workstation connected directly to the plant

  4. Monitoring biofouling in the seawater tunnel of a coastal power station

    International Nuclear Information System (INIS)

    Sasikumar, N.

    1994-01-01

    Water level difference (head loss) between the seawater intake and the forebay was used to determine the biofouling growth in the cooling-water tunnel of Madras atomic power station, India. During 1986-87, due to biofouling growth in the tunnel, the head loss dropped beyond the permissible limits required for operation of the power plant. The head loss showed an improvement during 1988 and 1989, after exomotive chlorination was adopted instead of shock chlorination. Fouling biomass estimated from the head loss showed a heavy biomass build-up of 535.52 ± 102 tonnes in the tunnel during 1992. The head loss showed a seasonal pattern, very similar to the settlement pattern of foulants in the coastal waters, with maximum values during summer months. On the basis of head-loss data, a suitable chlorination practice has been recommended to the power station. The experience suggested that a continuous monitoring of head loss is a simple and reliable method of estimating and controlling biofouling in power-plant cooling-water tunnels. (author)

  5. [Space-time water monitoring system at the Iriklinsk hydroelectric power station].

    Science.gov (United States)

    Deriabin, D G; Poliakov, E G; Priakhina, A A; Karimov, I F

    2002-01-01

    The Microbiosensor B 17677 F test system was applied to make a space-time monitoring of the biotoxicity of water used for production and everyday purposes at the Iriklinsk hydroelectric power station (IHEPS) and to identify the leading causes determining the biotoxicity of tested samples. There were seasonal variations in the biotoxicity with the maximum in spring and with minimum in winter and spring and a relationship of the spring rise in the biotoxicity to water pH changes. There was also an association of the certain values of the biotoxicity of industrial water with the concentration of petroleum products that are major pollutants at the IHEPS. The datum points that characterize the maximum level of technogenic exposure were identified.

  6. Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002

    International Nuclear Information System (INIS)

    Ouyang Junjie; Chen Yue

    2004-01-01

    This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10 4 , noble gas 2.03 x 10 4 , halogen 0.13, aerosol 7.57 x 10 -3 . For 110m Ag, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997

  7. Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

    Directory of Open Access Journals (Sweden)

    Uk-Won Nam

    2013-06-01

    Full Text Available Tissue equivalent proportional counter (TEPC can measure the Linear Energy Transfer (LET spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS. The prototype TEPC which can simulate a 2 μm of the site diameter for micro-dosimetry has been tested with a standard alpha source (241Am, 5.5 MeV. Also, the calibration of the TEPC was performed by the 252Cf neutron standard source in Korea Research Institute of Standards and Science (KRISS. The determined calibration factor was kf = 3.59×10-7 mSv/R.

  8. Simplified conversions between specific conductance and salinity units for use with data from monitoring stations

    Science.gov (United States)

    Schemel, Laurence E.

    2001-01-01

    The U.S. Geological Survey, Bureau of Reclamation, and the California Department of Water Resources maintain a large number of monitoring stations that record specific conductance, often referred to as “electrical conductivity,” in San Francisco Bay Estuary and the Sacramento-San Joaquin Delta. Specific conductance units that have been normalized to a standard temperature are useful in fresh waters, but conversion to salinity units has some considerable advantages in brackish waters of the estuary and Delta. For example, salinity is linearly related to the mixing ratio of freshwater and seawater, which is not the case for specific conductance, even when values are normalized to a standard temperature. The Practical Salinity Scale 1978 is based on specific conductance, temperature, and pressure measurements of seawater and freshwater mixtures (Lewis 1980 and references therein). Equations and data that define the scale make possible conversions between specific conductance and salinity values.

  9. Development of ICT for Leaching Monitoring in Taiwan Agricultural LTER Stations

    Directory of Open Access Journals (Sweden)

    Yankuang Chan

    2017-06-01

    Full Text Available In order to study the groundwater subsidy from different cropping systems, leaching monitoring in Taiwan started in 2008 and implemented agricultural long-term ecological research (LTER stations. Initially, leaching data was received by lysimeters, and then collected manually by laborers in the field twice per month. The cost of data collection and transmission is high, real-time monitoring is not possible, and maintenance of instruments is inefficient. In this study, the goal is to develop a data transmission path. ICT (Information and Communication Technology with different data transmission schemes was applied to improve the efficiency and immediacy of data transfer from the field to the databases in labs. Between 2010 and 2017, four versions of ICT have been developed and applied in LTER stations. WiFi, 2.5G (General Packet Radio Service, GPRS, 3G/4G network transmission, and Arduino cores are applied in different ICT versions. The first version of data transmission used data loggers, developed by the original factory, with a lower cost of renovation of instruments. However, complicated transmission paths, diverse instruments, poor weather resistance, and lack of wireless functionality are the limitations of the first version. Those limitations had been overcome by the second and third versions by using 2.5G (GPRS and 3G/4G network transmission, respectively. Nevertheless, these versions are limited to the processes of data compression and encryption transmission which were developed by the system vendors. In addition, data can only be collected through the webpage provided by the vendors, instead of being received directly from the database using SQL (Structured Query Language. This is inappropriate for advanced data treatment, organization, and analysis. Finally, the fourth version of data transmission has been developed using Arduino. This system allows redesigning of the data loggers and transmission instrument with more feasibility and

  10. Using a neural network approach and time series data from an international monitoring station in the Yellow Sea for modeling marine ecosystems.

    Science.gov (United States)

    Zhang, Yingying; Wang, Juncheng; Vorontsov, A M; Hou, Guangli; Nikanorova, M N; Wang, Hongliang

    2014-01-01

    The international marine ecological safety monitoring demonstration station in the Yellow Sea was developed as a collaborative project between China and Russia. It is a nonprofit technical workstation designed as a facility for marine scientific research for public welfare. By undertaking long-term monitoring of the marine environment and automatic data collection, this station will provide valuable information for marine ecological protection and disaster prevention and reduction. The results of some initial research by scientists at the research station into predictive modeling of marine ecological environments and early warning are described in this paper. Marine ecological processes are influenced by many factors including hydrological and meteorological conditions, biological factors, and human activities. Consequently, it is very difficult to incorporate all these influences and their interactions in a deterministic or analysis model. A prediction model integrating a time series prediction approach with neural network nonlinear modeling is proposed for marine ecological parameters. The model explores the natural fluctuations in marine ecological parameters by learning from the latest observed data automatically, and then predicting future values of the parameter. The model is updated in a "rolling" fashion with new observed data from the monitoring station. Prediction experiments results showed that the neural network prediction model based on time series data is effective for marine ecological prediction and can be used for the development of early warning systems.

  11. Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

    Science.gov (United States)

    Pilgrim, Jeffrey S.; Wood, William R.; Casias, Miguel E.; Vakhtin, Andrei B,; Johnson, Michael D.; Mudgett, Paul D.

    2014-01-01

    There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC

  12. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-08-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. A year into the life of this cooperative agreement, we note the following achievements: (1) Progress on the vertical line array (VLA) of sensors: (A) Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, (B) Cabling upgrade to allow installation of positioning sensors, (C) Adaptation of SDI's Angulate program to use acoustic slant ranges and DGPS data to compute and map the bottom location of the vertical array, (D) Progress in T''0'' delay and timing issues for improved control in data recording, (E) Successful deployment and recovery of the VLA twice during an October, 2003 cruise, once in 830m water, once in 1305m water, (F) Data collection and recovery from the DATS

  13. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-09-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements six months into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: Analysis and repair attempts of the VLA used in the deep water deployment during October 2003 have been completed; Definition of an interface protocol for the VLA DATS to the SFO has been established; Design modifications to allow integration of the VLA to the SFO have been made; Experience gained in the deployments of the first VLA is being applied to the design of the next VLAs; One of the two planned new VLAs being modified to serve as an Oceanographic Line Array (OLA). (2) Progress on the Sea Floor Probe: The decision to replace the Sea Floor Probe technology with the borehole emplacement of a geophysical array was reversed due to the 1300m water depth at the

  14. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    Carol Lutken

    2006-09-30

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The CMRET has conducted several research cruises during this reporting period

  15. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-11-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2

  16. Migration of carbon dioxide included micro-nano bubble water in porous media and its monitoring

    Science.gov (United States)

    Takemura, T.; Hamamoto, S.; Suzuki, K.; Koichi, O.

    2017-12-01

    The distributed CO2 storage is the small scale storage and its located near the emission areas. In the distributed CO2 storage, the CO2 is neutralized by sediment and underground water in the subsurface region (300-500m depth). Carbon dioxide (CO2) included micro-nano bubbles is one approach in neutralizing CO2 and sediments by increasing CO2 volume per unit volume of water and accelerating the chemical reaction. In order to design underground treatment for CO2 gas in the subsurface, it is required to elucidate the behavior of CO2 included micro-nano bubbles in the water. In this study, we carried out laboratory experiment using the soil tank, and measure the amount of leakage of CO2 gas at the surface. In addition, the process of migration of carbon dioxide included micro-nano bubble was monitored by the nondestructive method, wave velocity and resistivity.

  17. Development and radiation evaluation of mobile station for personnel monitoring system based on indigenous plastic scintillator sensor rods

    International Nuclear Information System (INIS)

    Chaudhary, H.S.; Parihar, A.; Senwar, K.R.; Prakash, V.; Rathore, A.S.

    2018-01-01

    The Mobile Station for Personnel Monitoring (MSPM) system has been designed and developed for rapid screening of personnel with respect to radiation contamination during nuclear or radiological emergency; it can also be used for prevention of illicit movement of radioactive sources. The objective was to develop a modular, transportable and easily deployable gamma portal monitoring system based on indigenous DLJ developed plastic scintillator sensors. The Gamma radiation response of the system is presented here

  18. Impacts on particles and ozone by transport processes recorded at urban and high-altitude monitoring stations

    Energy Technology Data Exchange (ETDEWEB)

    Nicolás, J.F., E-mail: j.nicolas@umh.es [Laboratory of Atmospheric Pollution (LCA), Miguel Hernández University, Av. de la Universidad s/n, Edif. Alcudia, 03202 Elche (Spain); Crespo, J.; Yubero, E.; Soler, R. [Laboratory of Atmospheric Pollution (LCA), Miguel Hernández University, Av. de la Universidad s/n, Edif. Alcudia, 03202 Elche (Spain); Carratalá, A. [Department of Chemical Engineering, University of Alicante, P.O. Box 99, 03080 Alicante (Spain); Mantilla, E. [Instituto Universitario CEAM-UMH, Parque Tecnológico, C/Charles R. Darwin 14, E-46980 Paterna (Spain)

    2014-01-01

    In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25–1 μm) at the mountain site, 55.0 ± 3.0 cm{sup − 3}, was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm{sup − 3}). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5–2 μm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1 cm{sup − 3} at the urban site and 0.9 ± 0.1 cm{sup − 3} at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of > 4.0 cm{sup − 3}, than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O{sub 3} levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3–17%) with respect to its mean

  19. Impacts on particles and ozone by transport processes recorded at urban and high-altitude monitoring stations

    International Nuclear Information System (INIS)

    Nicolás, J.F.; Crespo, J.; Yubero, E.; Soler, R.; Carratalá, A.; Mantilla, E.

    2014-01-01

    In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25–1 μm) at the mountain site, 55.0 ± 3.0 cm − 3 , was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm − 3 ). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5–2 μm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1 cm − 3 at the urban site and 0.9 ± 0.1 cm − 3 at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of > 4.0 cm − 3 , than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O 3 levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3–17%) with respect to its mean value. - Highlights:

  20. An automated DICOM database capable of arbitrary data mining (including radiation dose indicators) for quality monitoring.

    Science.gov (United States)

    Wang, Shanshan; Pavlicek, William; Roberts, Catherine C; Langer, Steve G; Zhang, Muhong; Hu, Mengqi; Morin, Richard L; Schueler, Beth A; Wellnitz, Clinton V; Wu, Teresa

    2011-04-01

    The U.S. National Press has brought to full public discussion concerns regarding the use of medical radiation, specifically x-ray computed tomography (CT), in diagnosis. A need exists for developing methods whereby assurance is given that all diagnostic medical radiation use is properly prescribed, and all patients' radiation exposure is monitored. The "DICOM Index Tracker©" (DIT) transparently captures desired digital imaging and communications in medicine (DICOM) tags from CT, nuclear imaging equipment, and other DICOM devices across an enterprise. Its initial use is recording, monitoring, and providing automatic alerts to medical professionals of excursions beyond internally determined trigger action levels of radiation. A flexible knowledge base, aware of equipment in use, enables automatic alerts to system administrators of newly identified equipment models or software versions so that DIT can be adapted to the new equipment or software. A dosimetry module accepts mammography breast organ dose, skin air kerma values from XA modalities, exposure indices from computed radiography, etc. upon receipt. The American Association of Physicists in Medicine recommended a methodology for effective dose calculations which are performed with CT units having DICOM structured dose reports. Web interface reporting is provided for accessing the database in real-time. DIT is DICOM-compliant and, thus, is standardized for international comparisons. Automatic alerts currently in use include: email, cell phone text message, and internal pager text messaging. This system extends the utility of DICOM for standardizing the capturing and computing of radiation dose as well as other quality measures.

  1. European experience on air and water pollution control: monitoring network and warning station

    Energy Technology Data Exchange (ETDEWEB)

    Aflalo, Sergio S. [Groupe Environnement S.A., Poissy (France)

    1993-12-31

    After a review of the energy consumption and pollutants emitted in the European Community, especially those concerning the `green house effect`, the author proceeded a summary of the actual legislation and Europeans directives, and also, the Best Available Technology for reducing air pollution is discussed. Original Air Quality monitoring networks performed by Environnement SA are described including measurements obtained around Paris and other areas of France. 7 refs., 11 figs.

  2. European experience on air and water pollution control: monitoring network and warning station

    Energy Technology Data Exchange (ETDEWEB)

    Aflalo, Sergio S [Groupe Environnement S.A., Poissy (France)

    1994-12-31

    After a review of the energy consumption and pollutants emitted in the European Community, especially those concerning the `green house effect`, the author proceeded a summary of the actual legislation and Europeans directives, and also, the Best Available Technology for reducing air pollution is discussed. Original Air Quality monitoring networks performed by Environnement SA are described including measurements obtained around Paris and other areas of France. 7 refs., 11 figs.

  3. The development of a volatile organics concentrator for use in monitoring Space Station water quality

    Science.gov (United States)

    Bodek, Itamar; Ehntholt, Daniel J.; Stolki, Thomas J.; Valentine, James R.; Trabanino, Rudy; Webb, Johanna V.; Sauer, Richard L.

    1991-01-01

    A breadboard concept of a volatile organics concentrator (VOC) is manufactured and tested for optimized water-quality analysis in a space environment. The VOC system is attached to a gas chromatograph/mass spectrometer to analyze the volatile chemicals relevant to the operation of Space Station Freedom. The preliminary tests include: (1) comparisons with analyses based on direct on-column injections of standards; (2) analyses of iodinated volatile organics; (3) comparisons of nitrogen vs helium as the chromatography carrier gas; and (4) measurements of collection efficiency. The VOC can analyze EPA method-624 analytes at comparable detection using flame-ionization detection and can analyze volatile iodinated compounds. The breadboard has good reproducibility and can use nitrogen as a carrier gas; good results are noted for the collection and concentration levels and for water removal.

  4. DOPA, a Digital Observatory for Protected Areas including Monitoring and Forecasting Services

    Science.gov (United States)

    Dubois, Gregoire; Hartley, Andrew; Peedell, Stephen; de Jesus, Jorge; Ó Tuama, Éamonn; Cottam, Andrew; May, Ian; Fisher, Ian; Nativi, Stefano; Bertrand, Francis

    2010-05-01

    The Digital Observatory for Protected Areas (DOPA) is a biodiversity information system currently developed as an interoperable web service at the Joint Research Centre of the European Commission in collaboration with other international organizations, including GBIF, UNEP-WCMC, Birdlife International and RSPB. DOPA is designed to assess the state and pressure of Protected Areas (PAs) and to prioritize them accordingly, in order to support decision making and fund allocation processes. To become an operational web service allowing the automatic monitoring of protected areas, DOPA needs to be able to capture the dynamics of spatio-temporal changes in habitats and anthropogenic pressure on PAs as well as the changes in the species distributions. Because some of the most valuable natural ecosystems and species on the planet cover large areas making field monitoring methods very difficult for a large scale assessment, the automatic collection and processing of remote sensing data are processes at the heart of the problem. To further be able to forecast changes due to climate change, DOPA has to rely on an architecture that enables it to communicate with the appropriate modeling web services. The purpose of this presentation is to present the architecture of the DOPA with special attention to e-Habitat, its web processing service designed for assessing the irreplaceability of habitats as well as for the modeling of habitats under different climate change scenarios. The use of open standards for spatial data and of open source programming languages for the development of the core functionalities of the system are expected to encourage the participation of the scientific community beyond the current partnerships and to favour the sharing of such an observatory which could be installed at any other location. Acknowledgement: Part of this work is funded under the 7th Framework Programme by the EuroGEOSS (www.eurogeoss.eu) project of the European Commission. The views

  5. New seismic monitoring observation system and data accessibility at Syowa Station

    Directory of Open Access Journals (Sweden)

    Masaki Kanao

    1999-03-01

    Full Text Available The seismic observation system at Syowa Station, East Antarctica was fully replaced in the wintering season of the 38th Japanese Antarctic Research Expedition (JARE-38 in 1996-1998. The old seismographic vault constructed in 1970 was closed at the end of JARE-38 because of cumulative damage to the inner side of the vault by continuous flowing in of water from walls in summer and its freezing in winter. All the seismometers were moved to a new seismographic hut (69°00′24.0″S, 39°35′06.0″E and 20m above mean sea level in April 1997. Seismic signals of the short-period (HES and broadband (STS-1 seismometers in the new hut are transmitted to the Earth Science Laboratory (ESL via analog cable 600m in length. The new acquisition system was installed in the ESL with 6-channel 24-bit A/D converters for both sensor signals. All digitized data are automatically transmitted from the A/D converter to a workstation via TCP/IP protocol. After parallel observations with the old acquisition system by personal computers and the new system during the wintering season of JARE-38,the main system was changed to the new one, which has some advantages for both the reduction of daily maintenance efforts and the data transport/communication processes via Internet by use of LAN at the station. In this report, details of the new seismographic hut and the recording system are described. Additionally, the seismic data accessibility for public use, including Internet service, is described.

  6. Elemental composition of aerosol particles from two atmospheric monitoring stations in the Amazon Basin

    International Nuclear Information System (INIS)

    Artaxo, P.; Gerab, F.; Rabello, M.L.C.

    1993-01-01

    One key region for the study of processes that are changing the composition of the global atmosphere is the Amazon Basin tropical rain forest. The high rate of deforestation and biomass burning is emitting large amounts of gases and fine-mode aerosol particles to the global atmosphere. Two background monitoring stations are operating continuously measuring aerosol composition, at Cuiaba, and Serra do Navio. Fine- and coarse-mode aerosol particles are being collected using stacked filter units. Particle induced X-ray emission (PIXE) was used to measure concentrations of up to 21 elements: Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr, Zr, and Pb. The elemental composition was measured at the new PIXE facility from the University of Sao Paulo, using a dedicated 5SDH tandem Pelletron nuclear accelerator. Absolute principal factor analysis (APFA) has derived absolute elemental source profiles. At the Serra do Navio sampling site a very clean background aerosol is being observed. Biogenic aerosol dominates the fine-mode mass concentration, with the presence of K, P, S, Cl, Zn, Br, and FPM. Three components dominate the aerosol composition: Soil dust particles, the natural biogenic release by the forest, and a marine aerosol component. At the Cuiaba site, during the dry season, a strong component of biomass burning is observed. An aerosol mass concentration up to 120 μg/m 3 was measured. APFA showed three components: Soil dust (Al, Ca, Ti, Mn, Fe), biomass burning (soot, FPM, K, Cl) and natural biogenic particles (K, S, Ca, Mn, Zn). The fine-mode biogenic component of both sites shows remarkable similarities, although the two sampling sites are 3000 km apart. Several essential plant nutrients like P, K, S, Ca, Ni and others are transported in the atmosphere as a result of biomass burning processes. (orig.)

  7. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  8. Thermal monitoring of hydrothermal activity by permanent infrared automatic stations: Results obtained at Solfatara di Pozzuoli, Campi Flegrei (Italy)

    Science.gov (United States)

    Chiodini, G.; Vilardo, G.; Augusti, V.; Granieri, D.; Caliro, S.; Minopoli, C.; Terranova, C.

    2007-12-01

    A permanent automatic infrared (IR) station was installed at Solfatara crater, the most active zone of Campi Flegrei caldera. After a positive in situ calibration of the IR camera, we analyze 2175 thermal IR images of the same scene from 2004 to 2007. The scene includes a portion of the steam heated hot soils of Solfatara. The experiment was initiated to detect and quantify temperature changes of the shallow thermal structure of a quiescent volcano such as Solfatara over long periods. Ambient temperature is the main parameter affecting IR temperatures, while air humidity and rain control image quality. A geometric correction of the images was necessary to remove the effects of slow movement of the camera. After a suitable correction the images give a reliable and detailed picture of the temperature changes, over the period October 2004 to January 2007, which suggests that origin of the changes were linked to anthropogenic activity, vegetation growth, and the increase of the flux of hydrothermal fluids in the area of the hottest fumaroles. Two positive temperature anomalies were registered after the occurrence of two seismic swarms which affected the hydrothermal system of Solfatara in October 2005 and October 2006. It is worth noting that these signs were detected in a system characterized by a low level of activity with respect to systems affected by real volcanic crisis where more spectacular results will be expected. Results of the experiment show that this kind of monitoring system can be a suitable tool for volcanic surveillance.

  9. Lymph node metastasis of carcinomas of transverse colon including flexures. Consideration of the extramesocolic lymph node stations.

    Science.gov (United States)

    Perrakis, Aristotelis; Weber, Klaus; Merkel, Susanne; Matzel, Klaus; Agaimy, Abbas; Gebbert, Carol; Hohenberger, Werner

    2014-10-01

    Complete mesocolic excision (CME) is nowadays state of the art in the treatment of colon cancer. In cases of carcinoma of transverse colon and of both flexures an extramesocolic lymph node metastasis can be found in the infrapancreatic lymph node region (ILR) and across the gastroepiploic arcade (GLR). These direct metastatic routes were not previously systematically considered. In order to validate our hypothesis of these direct metastatic pathways and to obtain evidence of our approach of including dissection of these areas as part of CME, we initiated a prospective study evaluating these lymph node regions during surgery. Forty-five consecutive patients with primary tumour manifestation in transverse colon and both flexures between May 2010 and January 2013 were prospectively analyzed. Patients were followed up for at least 6 months. Mode of surgery, histopathology, morbidity and mortality were evaluated. Twenty-six patients had a carcinoma of transverse colon, 16 patients one of hepatic flexure and four patients one of splenic flexure. The median lymph node yield was 40. Occurrence of lymph node metastasis in ILR was registered in five patients and in GLR in four patients. The mean lymph node ratio was 0.085. Postoperative complications occurred in nine patients, and postoperative mortality was 2 %. We were able to demonstrate this novel metastatic route of carcinomas of the transverse colon and of both flexures in ILR and GLR. These could be considered as regional lymph node regions and have to be included into surgery for cancer of the transverse colon including both flexures.

  10. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across American Samoa in 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across American Samoa in...

  11. IEEE Std 1205-1993: IEEE guide for assessing, monitoring, and mitigating aging effects on Class 1E equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The guidelines are provided for assessing, monitoring, and mitigating degradation of Class 1E equipment used in nuclear power generating stations due to aging. The methods described can be used to identify the performance capability of Class 1E equipment beyond its qualified life. A discussion of stressors and aging mechanisms is included. If aging considerations have been satisfactorily addressed through other means (e.g., equipment qualification), then use of this guide may not be warranted. For some equipment, only partial application of this guide may be warranted

  12. Present day geodynamics in Iceland monitored by a permanent network of continuous GPS stations

    Science.gov (United States)

    Völksen, Christof; Árnadóttir, Thóra; Geirsson, Halldór; Valsson, Guðmundur

    2009-12-01

    Iceland is located on the Mid-Atlantic Ridge and thereby offers a rare opportunity to study crustal movements at a divergent plate boundary. Iceland is not only characterized by the divergence of the Eurasian and North American Plates, as several active volcanoes are located on the island. Moderate size earthquakes occur in the transform zones, causing measurable crustal deformation. In 1999 the installation of a permanent network of continuous GPS stations (ISGPS) was initiated in order to observe deformation due to unrest in the Hengill volcanic system and at the Katla volcano. The ISGPS network has been enlarged over the years and consists today of more than 25 CGPS stations. Most of the stations are located along the plate boundary, where most of the active deformation takes place. Uplift due to post-glacial rebound due to the melting of the largest glacier in Europe, Vatnajökull, is also detected by the ISGPS network. This study presents results from analysis of 9 years of data from the ISGPS network, in the global reference frame PDR05, which has been evaluated by the Potsdam-Dresden-Reprocessing group with reprocessed GPS data only. We thus determine subsidence or land uplift in a global frame. The horizontal station velocities clearly show spreading across the plate boundary of about 20 mm/a. Stations in the vicinity of the glacier Vatnajökull indicate uplift in the range of 12 mm/a, while a station in the central part of Iceland shows uplift rates of about 25 mm/a. Tide gauge readings in Reykjavik and current subsidence rates observed with CGPS agree also quite well.

  13. Numerical modeling and monitoring analysis of Heroísmo station, Metro do Porto

    DEFF Research Database (Denmark)

    Ferreira, P.; Sousa, T.; Silva, P.

    2007-01-01

    Metro do Porto is a major light rail infrastructure built in the city of Porto and surrounding municipalities. In Porto's downtown, classified by UNESCO as World Heritage, the metro was built underground. From a technical point of view, one of the most challenging underground metro stations due t...

  14. CO2 Monitoring and Background Mole Fraction at Zhongshan Station, Antarctica

    Directory of Open Access Journals (Sweden)

    Yulong Sun

    2014-09-01

    Full Text Available Background CO2 mole fraction and seasonal variations, measured at Zhongshan station, Antarctica, for 2010 through 2013, exhibit the expected lowest mole fraction in March with a peak in November. Irrespective of wind direction, the mole fraction of CO2 distributes evenly after polluted air from station operations is removed from the data sets. The daily range of average CO2 mole fraction in all four seasons is small. The monthly mean CO2 mole fraction at Zhongshan station is similar to that of other stations in Antarctica, with seasonal CO2 amplitudes in the order of 384–392 µmol∙mol−1. The annual increase in recent years is about 2 µmol∙mol−1∙yr−1. There is no appreciable difference between CO2 mole fractions around the coast of Antarctica and in the interior, showing that CO2 observed in Antarctica has been fully mixed in the atmosphere as it moves from the north through the southern hemisphere.

  15. Characterization of selected volatile organic compounds, polycyclic aromatic hydrocarbons and carbonyl compounds at a roadside monitoring station

    Science.gov (United States)

    Ho, K. F.; Lee, S. C.; Chiu, Gloria M. Y.

    Volatile organic compounds (VOCs), PAHs and carbonyl compounds are the major toxic components in Hong Kong. Emissions from motor vehicles have been one of the primary pollution sources in the metropolitan areas throughout Hong Kong for a long time. A 1-yr monitoring program for VOCs, PAHs and carbonyl compounds had been performed at a roadside urban station at Hong Kong Polytechnic University in order to determine the variations and correlations of each selected species (VOCs, PAHs and carbonyl compounds). This study is aimed to analyze toxic volatile organic compounds (benzene, toluene, ethylbenzene and xylene), two carbonyl compounds (formaldehyde, acetaldehyde), and selective polycyclic aromatic hydrocarbons. The monitoring program started from 16 April 1999 to 30 March 2000. Ambient VOC concentrations, many of which originate from the same sources as particulate PAHs and carbonyls compounds, show significant quantities of benzene, toluene and xylenes. Correlations and multivariate analysis of selected gaseous and particulate phase organic pollutants were performed. Source identification by principle component analysis and hierarchical cluster analysis allowed the identification of four sources (factors) for the roadside monitoring station. Factor 1 represents the effect of diesel vehicle exhaust. Factor 2 shows the contribution of aromatic compounds. Factor 3 explains photochemical products—formaldehyde and acetaldehyde. Factor 4 explains the effect of gasoline vehicle exhaust.

  16. Radioactivity monitoring by the official monitoring stations in North-Rhine Westphalia and the Juelich Nuclear Research Centre after the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    1986-01-01

    This official report presents a governmental declaration of the prime minister of NRW, Mr. Rau, concerning the reactor accident at Chernobyl, and a joint declaration of ministers of NRW, concerning the impact of the accident on the Land NRW. These statements are completed by six official reports on radioactivity measurements carried out by the official monitoring stations of the Land and by the KFA Juelich. These reports inform about methods, scope, and results of the measuring campaigns accomplished by the Zentralstelle fuer Sicherheitstechnik (ZFS), the public materials testing office (MPA), the Chemisches Untersuchungsamt, the Landesamt fuer Wasser und Abfall, and the KFA Juelich. (DG) [de

  17. Environmental Radiation Surveillance Results from over the Last Decade of Operational Experience at the Regional Radiation Monitoring Stations(RRMS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hae Young [Daegu Regional Radiation Monitoring Station, Daegu (Korea, Republic of); Yoo, Dong Han [Ulsan Regional Radiation Monitoring Station, Ulsan (Korea, Republic of); Lee, Sang Hoon [Kyungpook National University, Daegu (Korea, Republic of)

    2015-10-15

    The objectives of the current program are to monitor environmental radiation/radioactivity level in Korea and to provide the base-line data on environmental radiation/radioactivity which will be useful in the case of radiological emergency situations. This program plays an important role in the view of protecting the public health against the potential hazards of radiation and maintaining a clean environment. This paper describes an introduction to the Regional Radiation Monitoring Stations (RRMS), and also presents some results of recent years (2001-2014). The environmental radiation surveillance results of years 2001-2014 have been described. It indicates normal levels of radiation in the past years. These kinds of studies are very important in providing references in understanding the environmental radioactivity level in a particular region.

  18. Condition monitoring and signature analysis techniques as applied to Madras Atomic Power Station (MAPS) [Paper No.: VIA - 1

    International Nuclear Information System (INIS)

    Rangarajan, V.; Suryanarayana, L.

    1981-01-01

    The technique of vibration signature analysis for identifying the machine troubles in their early stages is explained. The advantage is that a timely corrective action can be planned to avoid breakdowns and unplanned shutdowns. At the Madras Atomic Power Station (MAPS), this technique is applied to regularly monitor vibrations of equipment and thus is serving as a tool for doing corrective maintenance of equipment. Case studies of application of this technique to main boiler feed pumps, moderation pump motors, centrifugal chiller, ventilation system fans, thermal shield ventilation fans, filtered water pumps, emergency process sea water pumps, and antifriction bearings of MAPS are presented. Condition monitoring during commissioning and subsequent operation could indicate defects. Corrective actions which were taken are described. (M.G.B.)

  19. The capacity of radar, crowdsourced personal weather stations and commercial microwave links to monitor small scale urban rainfall

    Science.gov (United States)

    Uijlenhoet, R.; de Vos, L. W.; Leijnse, H.; Overeem, A.; Raupach, T. H.; Berne, A.

    2017-12-01

    For the purpose of urban rainfall monitoring high resolution rainfall measurements are desirable. Typically C-band radar can provide rainfall intensities at km grid cells every 5 minutes. Opportunistic sensing with commercial microwave links yields rainfall intensities over link paths within cities. Additionally, recent developments have made it possible to obtain large amounts of urban in situ measurements from weather amateurs in near real-time. With a known high resolution simulated rainfall event the accuracy of these three techniques is evaluated, taking into account their respective existing layouts and sampling methods. Under ideal measurement conditions, the weather station networks proves to be most promising. For accurate estimation with radar, an appropriate choice for Z-R relationship is vital. Though both the microwave links and the weather station networks are quite dense, both techniques will underestimate rainfall if not at least one link path / station captures the high intensity rainfall peak. The accuracy of each technique improves when considering rainfall at larger scales, especially by increasing time intervals, with the steepest improvements found in microwave links.

  20. Application of Terrestrial Ecosystem Monitoring under the CAFF Circumpolar Biodiversity Monitoring Program: Designing and Implementing Terrestrial Monitoring to Establish the Canadian High Arctic Research Station as a Flagship Arctic Environmental Monitoring Site

    Science.gov (United States)

    McLennan, D.; Kehler, D.

    2016-12-01

    The Canadian High Arctic Research Station (CHARS) is scheduled for completion in July 2017 and is the northern science component of Polar Knowledge Canada (POLAR). A mandated goal for POLAR is to establish the adjacent Experimental and Reference Area (ERA) as an Arctic Flagship monitoring site that will track change in Arctic terrestrial, freshwater and marine ecosystems. Situated in the community of Cambridge Bay, CHARS provides the opportunity to draw on the Indigenous Knowledge of local residents to help design and conduct the monitoring, and to operate 12 months a year. Monitoring at CHARS will be linked to networks nationally and internationally, and is being designed so that change in key indicators can be understood in terms of drivers and processes, modeled and scaled up regionally, and used to predict important changes in critical indicators. As a partner in the Circumpolar Biodiversity Monitoring Program (CBMP), the monitoring design for terrestrial ecosystems follows approaches outlined by the CBMP Terrestrial Expert Monitoring Group, who have listed key monitoring questions and identified a list of important Focal Ecosystem Components (FECs). To link drivers to FECs we are proposing a multi-scaled approach: 1) an Intensive Monitoring Area to establish replicated monitoring plots that track change in snow depth and condition, active layer depth, soil temperature, soil moisture, and soil solution chemistry that are spatially and temporally linked to changes in microbiological activity, CO2/CH4 net ecosystem flux, vegetation relative frequency, species composition, growth and foliar nutrient concentration, arthropod abundance, lemming abundance and health, and shorebird/songbird abundance and productivity. 2) These intensive observations are supported by watershed scale measures that will monitor, during the growing season, lemming winter nest abundance, songbird, shorebird and waterfowl staging and nesting, and other observations; in the winter we will

  1. EPA Office of Water (OW): STORET Water Quality Monitoring Stations NHDPlus Indexed Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  2. Detection of Atmospheric Explosions at IMS Monitoring Stations using Infrasound Techniques

    National Research Council Canada - National Science Library

    Christie, Douglas R; Kennett, Brian L; Tarlowski, Chris

    2006-01-01

    Work is continuing on the development of infrasound techniques that can be used to improve detection, location and discrimination capability for atmospheric nuclear explosions at International Monitoring System (IMS...

  3. EPA Office of Water (OW): STORET Water Quality Monitoring Stations Source Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  4. Monitoring surface-water quality in Arizona: the fixed-station network

    Science.gov (United States)

    Tadayon, Saeid

    2000-01-01

    Arizona is an arid State in which economic development is influenced largely by the quantity and quality of water and the location of adequate water supplies. In 1995, surface water supplied about 58 percent of total withdrawals in Arizona. Of the total amount of surface water used in 1995, about 89 percent was for agriculture, 10 percent for public supply, and 1 percent for industrial supply (including mining and thermoelectric; Solley and others, 1998). As a result of rapid population growth in Arizona, historic agricultural lands in the Phoenix (Maricopa County) and Tucson (Pima County) areas are now being developed for residential and commercial use; thus, the amount of water used for public supply is increasing. The Clean Water Act was established by U.S. Congress (1972) in response to public concern about water-pollution control. The act defines a process by which the United States Congress and the citizens are informed of the Nation’s progress in restoring and maintaining the quality of our waters. The Arizona Department of Environmental Quality (ADEQ) is the State-designated agency for this process and, as a result, has developed a monitoring program to assess water quality in Arizona. The ADEQ is required to submit a water-quality assessment report to the United States Environmental Protection Agency (USEPA) every 2 years. The USEPA summarizes the reports from each State and submits a report to the Congress characterizing water quality in the United States. These reports serve to inform Congress and the public of the Nation’s progress toward the restoration and maintenance of water quality in the United States (Arizona Department of Environmental Quality, 1998).

  5. Monitoring of the Crab Nebula with Chandra and Other Observatories Including HST

    Science.gov (United States)

    Weisskopf, Martin C.

    2014-01-01

    Subsequent to the detections AGILE and Fermi/LAT of the gamma-ray flares from the Crab Nebula in the fall of 2010, this team has been monitoring the X-Ray emission from the Crab on a regular basis. X-Ray observations have taken place typically once per month when viewing constraints allow and more recently four times per year. There have been notable exceptions, e.g. in April of 2011 and March 2013 when we initiated a set of Chandra Target of opportunity observations in conjunction with bright gamma-ray flares. For much of the time regular HST observations were made in conjunction with the Chandra observations. The aim of this program to further characterize, in depth, the X-Ray and optical variations that take place in the nebula, and by so doing determine the regions which contribute to the harder X-ray variations and, if possible, determine the precise location within the Nebula of the origin of the gamma-ray flares. As part of this project members of the team have developed Singular Value Decomposition techniques to sequences of images in order to more accurately characterize features. The current status of the project will be presented highlighting studies of the inner knot and possible correlations with the flares.

  6. Support of Gulf of Mexico Hydrate Research Consortium: Activities of Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas McGee; Carol Lutken

    2008-05-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research that shared the need for a way to conduct investigations of gas hydrates and their stability zone in the Gulf of Mexico in situ on a more-or-less continuous basis. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (SFO) on the sea floor in the northern Gulf of Mexico, in an area where gas hydrates are known to be present at, or just below, the sea floor and to discover the configuration and composition of the subsurface pathways or 'plumbing' through which fluids migrate into and out of the hydrate stability zone (HSZ) to the sediment-water interface. Monitoring changes in this zone and linking them to coincident and perhaps consequent events at the seafloor and within the water column is the eventual goal of the Consortium. This mission includes investigations of the physical, chemical and biological components of the gas hydrate stability zone - the sea-floor/sediment-water interface, the near-sea-floor water column, and the shallow subsurface sediments. The eventual goal is to monitor changes in the hydrate stability zone over time. Establishment of the Consortium succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among those involved in gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative methods and construct necessary instrumentation. Following extensive investigation into candidate sites, Mississippi Canyon 118 (MC118) was chosen by consensus of the Consortium at their fall, 2004, meeting as the site most likely to satisfy all criteria established by the group. Much of the preliminary work preceding the establishment of the site - sensor development and testing, geophysical surveys, and laboratory studies - has been reported in

  7. Long-term monitoring of persistent organic pollutants (POPs) at the Norwegian Troll station in Dronning Maud Land, Antarctica

    Science.gov (United States)

    Kallenborn, R.; Breivik, K.; Eckhardt, S.; Lunder, C. R.; Manø, S.; Schlabach, M.; Stohl, A.

    2013-07-01

    A first long-term monitoring of selected persistent organic pollutants (POPs) in Antarctic air has been conducted at the Norwegian research station Troll (Dronning Maud Land). As target contaminants 32 PCB congeners, α- and γ-hexachlorocyclohexane (HCH), trans- and cis-chlordane, trans- and cis-nonachlor, p,p'- and o,p-DDT, DDD, DDE as well as hexachlorobenzene (HCB) were selected. The monitoring program with weekly samples taken during the period 2007-2010 was coordinated with the parallel program at the Norwegian Arctic monitoring site (Zeppelin mountain, Ny-Ålesund, Svalbard) in terms of priority compounds, sampling schedule as well as analytical methods. The POP concentration levels found in Antarctica were considerably lower than Arctic atmospheric background concentrations. Similar to observations for Arctic samples, HCB is the predominant POP compound, with levels of around 22 pg m-3 throughout the entire monitoring period. In general, the following concentration distribution was found for the Troll samples analyzed: HCB > Sum HCH > Sum PCB > Sum DDT > Sum chlordanes. Atmospheric long-range transport was identified as a major contamination source for POPs in Antarctic environments. Several long-range transport events with elevated levels of pesticides and/or compounds with industrial sources were identified based on retroplume calculations with a Lagrangian particle dispersion model (FLEXPART).

  8. Long-term monitoring of persistent organic pollutants (POPs at the Norwegian Troll station in Dronning Maud Land, Antarctica

    Directory of Open Access Journals (Sweden)

    R. Kallenborn

    2013-07-01

    Full Text Available A first long-term monitoring of selected persistent organic pollutants (POPs in Antarctic air has been conducted at the Norwegian research station Troll (Dronning Maud Land. As target contaminants 32 PCB congeners, α- and γ-hexachlorocyclohexane (HCH, trans- and cis-chlordane, trans- and cis-nonachlor, p,p'- and o,p-DDT, DDD, DDE as well as hexachlorobenzene (HCB were selected. The monitoring program with weekly samples taken during the period 2007–2010 was coordinated with the parallel program at the Norwegian Arctic monitoring site (Zeppelin mountain, Ny-Ålesund, Svalbard in terms of priority compounds, sampling schedule as well as analytical methods. The POP concentration levels found in Antarctica were considerably lower than Arctic atmospheric background concentrations. Similar to observations for Arctic samples, HCB is the predominant POP compound, with levels of around 22 pg m−3 throughout the entire monitoring period. In general, the following concentration distribution was found for the Troll samples analyzed: HCB > Sum HCH > Sum PCB > Sum DDT > Sum chlordanes. Atmospheric long-range transport was identified as a major contamination source for POPs in Antarctic environments. Several long-range transport events with elevated levels of pesticides and/or compounds with industrial sources were identified based on retroplume calculations with a Lagrangian particle dispersion model (FLEXPART.

  9. Predictive monitoring and diagnosis of periodic air pollution in a subway station.

    Science.gov (United States)

    Kim, YongSu; Kim, MinJung; Lim, JungJin; Kim, Jeong Tai; Yoo, ChangKyoo

    2010-11-15

    The purpose of this study was to develop a predictive monitoring and diagnosis system for the air pollutants in a subway system using a lifting technique with a multiway principal component analysis (MPCA) which monitors the periodic patterns of the air pollutants and diagnoses the sources of the contamination. The basic purpose of this lifting technique was to capture the multivariate and periodic characteristics of all of the indoor air samples collected during each day. These characteristics could then be used to improve the handling of strong periodic fluctuations in the air quality environment in subway systems and will allow important changes in the indoor air quality to be quickly detected. The predictive monitoring approach was applied to a real indoor air quality dataset collected by telemonitoring systems (TMS) that indicated some periodic variations in the air pollutants and multivariate relationships between the measured variables. Two monitoring models--global and seasonal--were developed to study climate change in Korea. The proposed predictive monitoring method using the lifted model resulted in fewer false alarms and missed faults due to non-stationary behavior than that were experienced with the conventional methods. This method could be used to identify the contributions of various pollution sources. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. A microcontroller-based data-acquisition system for meteorological station monitoring

    International Nuclear Information System (INIS)

    Rosiek, S.; Batlles, F.J.

    2008-01-01

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out

  11. A microcontroller-based data-acquisition system for meteorological station monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, S.; Batlles, F.J. [Dpto. Fisica Aplicada, Universidad de Almeria, 04120 Almeria (Spain)

    2008-12-15

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from the University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out. (author)

  12. Evaluation of available analytical techniques for monitoring the quality of space station potable water

    Science.gov (United States)

    Geer, Richard D.

    1989-01-01

    To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

  13. Universal chitosan-assisted synthesis of Ag-including heterostructured nanocrystals for label-free in situ SERS monitoring.

    Science.gov (United States)

    Cai, Kai; Xiao, Xiaoyan; Zhang, Huan; Lu, Zhicheng; Liu, Jiawei; Li, Qin; Liu, Chen; Foda, Mohamed F; Han, Heyou

    2015-12-07

    A universal chitosan-assisted method was developed to synthesize various Ag-including heterostructured nanocrystals, in which chelation probably plays a vital role. The as-prepared Ag/Pd heterostructured nanocrystals show outstanding properties when used as bifunctional nanocomposites in label-free in situ SERS monitoring of Pd-catalyzed reaction.

  14. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    Science.gov (United States)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.

  15. Monitoring for vertical creep in concrete in two silos at Wivenhoe pumped storage hydro power station

    Energy Technology Data Exchange (ETDEWEB)

    Harris, M W [Queensland Univ. of Technology, Brisbane (Australia). School of Surveying

    1997-12-31

    The need for structural monitoring is generated by expected or unexpected (newly discovered in the life of the structure) behaviour. Due to the long vertical driveshafts involved at Wivenhoe the phenomenon of `concrete creep` which, if it is occurring, could contribute to shaft misalignment and unscheduled bearing wear or failure, was used as a motivation to establish a vertical monitoring system. The particular system developed for this site is traceable, replaceable, expandable and inexpensive. Measurements are obtained by precise levelling and the use of specially calibrated vertically suspended tapes. The analysis of the vertical loops is performed using constrained variance estimation and `robust` inter-epoch comparison. (orig.)

  16. Hydrogeological monitoring (0-15 km of the Chernobyl' station affected zone)

    International Nuclear Information System (INIS)

    Sitnikov, A.B.; Dzheko, S.P.

    1992-01-01

    Hydrogeological monitoring (HM) is aimed at finding out the regularities of formation of subsurface water, as well as unfavorable phenomena and parameters used for forecasts. To the main objects of HM belong: surface storm run-off; soil moisture of the aeration zone; underground water; water-bearing horizons in Buchak and Senomazh depositions. Criteria for grounding the system of monitoring and control are presented. The elements of the system for tracking local HM in 10-15 km zone are given. Potential centres of unfavorable phenomena, as well as the objects to be protected are noted. 3 figs

  17. Monitoring for vertical creep in concrete in two silos at Wivenhoe pumped storage hydro power station

    Energy Technology Data Exchange (ETDEWEB)

    Harris, M.W. [Queensland Univ. of Technology, Brisbane (Australia). School of Surveying

    1996-12-31

    The need for structural monitoring is generated by expected or unexpected (newly discovered in the life of the structure) behaviour. Due to the long vertical driveshafts involved at Wivenhoe the phenomenon of `concrete creep` which, if it is occurring, could contribute to shaft misalignment and unscheduled bearing wear or failure, was used as a motivation to establish a vertical monitoring system. The particular system developed for this site is traceable, replaceable, expandable and inexpensive. Measurements are obtained by precise levelling and the use of specially calibrated vertically suspended tapes. The analysis of the vertical loops is performed using constrained variance estimation and `robust` inter-epoch comparison. (orig.)

  18. Long-term trends in airborne SO2 in an air quality monitoring station in Seoul, Korea, from 1987 to 2013.

    Science.gov (United States)

    Khan, Azmatullah; Kim, Ki-Hyun; Szulejko, Jan E; Brown, Richard J C; Jeon, Eui-Chan; Oh, Jong-Min; Shin, Yong Soon; Adelodun, Adedeji A

    2017-08-01

    Atmospheric concentration of sulfur dioxide (SO 2 ) was intermittently measured at an air quality monitoring (AQM) station in the Yong-san district of Seoul, Korea, between 1987 and 2013. The SO 2 level was compared with other important pollutants concurrently measured, including methane (CH 4 ), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ), ozone (O 3 ), and particulate matter (PM 10 ). If split into three different periods (period 1, 1987-1988, period 2, 1999-2000, and period 3, 2004-2013), the respective mean [SO 2 ] values (6.57 ± 4.29, 6.30 ± 2.44, and 5.29 ± 0.63 ppb) showed a slight reduction across the entire study period. The concentrations of SO 2 are found to be strongly correlated with other pollutants such as CO (r = 0.614, p = 0.02), which tracked reductions in reported emissions due to tighter emissions standards enacted by the South Korean government. There was also a clear seasonal trend in the SO 2 level, especially in periods 2 and 3, reflecting the combined effects of domestic heating by coal briquettes and meteorological conditions. Although only a 16% concentration reduction was achieved during the 27-year study duration, this is significant if one considers rapid urbanization, an 83.2% increase in population, and rapid industrialization that took place during that period. Since 1970, a network of air quality monitoring (AQM) stations has been operated by the Korean Ministry of Environment (KMOE) for routine nationwide monitoring of air pollutant concentrations in urban/suburban areas. To date, the information obtained from these stations has provided a platform for analyzing long-term trends of major pollutant species. In this study, we examined the long-term trends of SO 2 levels and relevant environmental parameters monitored continuously in the Yong-san district of Seoul between 1987 and 2013. The data were analyzed over various time scales (i.e., monthly, seasonal, and annual intervals). The results obtained from

  19. Monitoring and conservation of power station components; Ueberwachung der Konservierung von Kraftwerkskomponenten

    Energy Technology Data Exchange (ETDEWEB)

    Weber, R.; Mohr, G. [Allianz-Zentrum fuer Technik GmbH (AZT), Ismaning (Germany)

    2000-07-01

    There are very many reasons why power station components should be treated and conserved as high-value industrial goods. Various considerations, such as transport type and distance and storage duration and location, then become important. This article deals with the special problems and considers the corresponding fundamentals on the basis of a specific example. Emphasis is given to the effects of atmosphere and climate but also to various corrosive mechanisms and to packing and conservation. (orig.) [German] Als hochwertige Industriegueter muessen Kraftwerkskomponenten aus unterschiedlichsten Gruenden konserviert werden. Dabei sind verschiedenerlei Gesichtspunkte massgeblich, wie Transportart und -weg sowie Lagerungsdauer und -ort. Hier wird anhand eines konkreten Beispiels ueber diese spezielle Problematik und die entsprechenden Grundlagen berichtet. Im Vordergrund stehen Einfluesse von Atmosphaere und Klima, aber auch diverse Korrosionsmechanismen sowie Verpackung und Konservierung. (orig.)

  20. Operation and maintenance of thermal power stations best practices and health monitoring

    CERN Document Server

    Chanda, Pradip

    2016-01-01

    This book illustrates operation and maintenance practices/guidelines for economic generation and managing health of a thermal power generator beyond its regulatory life. The book provides knowledge for professionals managing power station operations, through its unique approach to chemical analysis of water, steam, oil etc. to identify malfunctioning/defects in equipment/systems much before the physical manifestation of the problem. The book also contains a detailed procedure for conducting performance evaluation tests on different equipment, and for analyzing test results for predicting maintenance requirements, which has lent a new dimension to power systems operation and maintenance practices. A number of real life case studies also enrich the book. This book will prove particularly useful to power systems operations professionals in the developing economies, and also to researchers and students involved in studying power systems operations and control. .

  1. Monitoring the risk of loss of heat sink during plant shutdowns at Bruce Generating Station 'A'

    International Nuclear Information System (INIS)

    Krishnan, K.S.; Mancuso, F.; Vecchiarelli, D.

    1996-01-01

    A relatively simple loss of shutdown heat sink fault tree model has been developed and used during unit outages at Bruce Nuclear Generation Station 'A' to assess, from a risk and reliability perspective, alternative heat sink strategies and to aid in decisions on allowable outage configurations. The model is adjusted to reflect the various unit configurations planned during a specific outage, and identifies events and event combinations leading to loss of fuel cooling. The calculated failure frequencies are compared to the limits consistent with corporate and international public safety goals. The importance measures generated by the interrogation of the fault tree model for each outage configuration are also used to reschedule configurations with high fuel damage frequency later into the outage and to control the configurations with relatively high probability of fuel damage to short intervals at the most appropriate time into the outage. (author)

  2. Monitoring of radionuclides in the environs of the Finnish nuclear power stations in 1988

    International Nuclear Information System (INIS)

    Klemola, S.; Ilus, E.; Sjoeblom, K.L.; Arvela, H.; Blomqvist, L.

    1991-03-01

    Monitoring of radionuclides around Finnish nuclear power plants continued in 1988 with the regular programmes. About 1000 samples were analysed from both terrestrial and aquatic environments.The dominant artificial radioactive substances in the vicinity of power plants were still the fallout nuclides from the Chernobyl accident, but the concentrations in all the objects monitored are lower than in the previous year. Trace amounts of activation products originating from the airborne releases of local power plants were detected in some air and deposition samples. Discharged nuclides were more abundant in the aquatic environment, especially in samples of indicator organisms. However, their contribution to the radiation doses received by the the public was very small. (orig.)

  3. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance of Climate Stations at Wake Island from 2014-03-16 to 2014-03-20 (NCEI Accession 0159160)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  4. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    June, 1999. The chief aims of such experiments are to allow the participants to check their home calibrations of their detectors and to compare the responses of the individual environmental radiation measurement systems used in the different EU member states and making a link between the different...... a simulation of a radioactive plume passing over the monitors during a certain time was made using a specially designed source set up in the field that was able to vary the air kerma rate from low activity Cs-137 sources additional to the natural air kerma rate. It is demonstrated that a typical environmental...

  5. Hydrate research activities that both support and derive from the monitoring station/sea-floor Observatory, Mississippi Canyon 118, northern Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Lutken, Carol [Univ. of Mississippi, Oxford, MS (United States). Center for Marine Resources and Environmental Technology (CMRET)

    2013-07-31

    A permanent observatory has been installed on the seafloor at Federal Lease Block, Mississippi Canyon 118 (MC118), northern Gulf of Mexico. Researched and designed by the Gulf of Mexico Hydrates Research Consortium (GOM-HRC) with the geological, geophysical, geochemical and biological characterization of in situ gas hydrates systems as the research goal, the site has been designated by the Bureau of Ocean Energy Management as a permanent Research Reserve where studies of hydrates and related ocean systems may take place continuously and cooperatively into the foreseeable future. The predominant seafloor feature at MC118 is a carbonate-hydrate complex, officially named Woolsey Mound for the founder of both the GOM-HRC and the concept of the permanent seafloor hydrates research facility, the late James Robert “Bob” Woolsey. As primary investigator of the overall project until his death in mid-2008, Woolsey provided key scientific input and served as chief administrator for the Monitoring Station/ Seafloor Observatory (MS-SFO). This final technical report presents highlights of research and accomplishments to date. Although not all projects reached the status originally envisioned, they are all either complete or positioned for completion at the earliest opportunity. All Department of Energy funds have been exhausted in this effort but, in addition, leveraged to great advantage with additional federal input to the project and matched efforts and resources. This report contains final reports on all subcontracts issued by the University of Mississippi, Administrators of the project, Hydrate research activities that both support and derive from the monitoring station/sea-floor Observatory, Mississippi Canyon 118, northern Gulf of Mexico, as well as status reports on the major components of the project. All subcontractors have fulfilled their primary obligations. Without continued funds designated for further project development, the Monitoring Station

  6. Impact of secondary inorganic aerosol and road traffic at a suburban air quality monitoring station.

    Science.gov (United States)

    Megido, L; Negral, L; Castrillón, L; Fernández-Nava, Y; Suárez-Peña, B; Marañón, E

    2017-03-15

    PM10 from a suburban site in the northwest of Spain was assessed using data from chemical determinations, meteorological parameters, aerosol maps and five-day back trajectories of air masses. Temporal variations in the chemical composition of PM10 were subsequently related to stationary/mobile local sources and long-range transport stemming from Europe and North Africa. The presence of secondary inorganic species (sulphates, nitrates and ammonium) in airborne particulate matter constituted one of the main focuses of this study. These chemical species formed 16.5% of PM10 on average, in line with other suburban background sites in Europe. However, a maximum of 47.8% of PM10 were recorded after several days under the influence of European air masses. Furthermore, the highest values of these three chemical species coincided with episodes of poor air circulation and influxes of air masses from Europe. The relationship between SO 4 2- and NH 4 + (R 2  = 0.57, p-valueforest fires. On isolated days, combustion was estimated to contribute up to 21.0 μg PM/m 3 (50.8% of PM10). The contribution from industrial processes to this source is also worth highlighting given the presence of Ni and Co in its profile. Furthermore, African dust outbreaks at the sampling site, characterised by an arc through the Atlantic Ocean, were usually associated with a higher concentration of Al 2 O 3 in PM10. Results evidenced the relevance of stationary (i.e., steelworks and thermal power station) and mobile sources in the air quality at the suburban site under study, with important apportionments of particulate matter coming from road traffic and as consequence of releasing precursor gases of secondary particles to the atmosphere. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Hybrid radiation background monitoring in operational control and forecasting of environmental contamination by nuclear power station discharges

    International Nuclear Information System (INIS)

    Ermeev, I.S.; Eremenko, V.A.; Makarov, Y.A.; Matueev, V.V.; Zhernov, V.S.

    1986-01-01

    Rapid developments in nuclear power have stimulated research on monitoring and forecasting environmental radiation pollution (ERP), and in particular the amounts, compositions, and distributions of radionuclides in the environment. A conceptual model is presented for hybrid environmental radiation pollution monitoring. When there is an emergency, the model operates in a fashion most closely corresponding to the actual meteorological conditions, and the ERP data given by the model enable one to distinguish changes due to the man-made component from random fluctuations in the natural background. The measurement system in general includes mobile and stationary data-acquisition facilities linked by wire or radio to the central point. The system also accumulates and stores data on the radiation environment, which are edited on the basis of radioactive, chemical, and other transformations. The purpose of hybrid monitoring is ultimately to analyze trends in order to detect elevated discharges and thus to output data to the regional monitoring system

  8. Electric Power Plants and Generation Stations, Power Plants - is a seperate layer, however, we have them included in local building layer as well, Published in 2010, 1:2400 (1in=200ft) scale, Effingham County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Power Plants and Generation Stations dataset current as of 2010. Power Plants - is a seperate layer, however, we have them included in local building layer...

  9. Monitoring of radioactivity in the environs of Finnish nuclear power stations in 1987

    International Nuclear Information System (INIS)

    Sjoeblom, K.-L.; Klemola, S.; Ilus, E.; Arvela, H.; Blomqvist, L.

    1989-06-01

    Results of the environmental programmes for monitoring radioactive contamination around Finnish nuclear power plants in 1987 are reported. Fallout from the Chernobyl accident, which took place in April 1986, was still dominating the artificial radiation situation in Finland. Thus, large amounts of 137 Cs and other long-lived fallout nuclides predominated in the environmental samples taken in the vicinity of nuclear power plants. The extremely small airborne releases from Finnish nuclear power plants were almost totally covered by fallout nuclides. The somewhat higher aquatic releases were easier to distinguish, and it was possible to follow their spread in the marine environment. The contribution of locally discharged nuclides to radiation doses of the population was insignificant

  10. Sensing loop performance monitoring in the safety systems of nuclear power stations

    International Nuclear Information System (INIS)

    Colley, R.C.; Widmeyer, M.; Weiss, J.H.; Wiegle, H.R.

    1991-01-01

    This paper reports on plant technical specifications and NRC regulatory guides which require testing of sensing loops to detect degradation and failure. Industry efforts have focused on specific manual testing to detect individual failure modes such as increased response time and calibration drift. Recent work performed by EPRI and by others using instrument loop data, failure modes, and effects analyses (FMEAs), and experience with utility on-line sensor health monitoring programs has established qualitative physical models of the sensing loop. This methodology has demonstrated that sensing loop cross comparison techniques can provide equivalent indication of sensing loop performance. It also provides more frequent sensing loop health indication than manual testing and reduces the requirement for manual testing

  11. Understanding the Effect of Stratification on Vertical and Temporal Heterogenieties of Cyanobacteria Blooms in Lakes Using a Long Term in-situ Monitoring Station

    Science.gov (United States)

    Wilkinson, A.; Guala, M.; Hondzo, M.

    2017-12-01

    Harmful Algal Blooms (HAB) are made up of potentially toxic freshwater microorganisms called cyanobacteria, because of this they are a ecological and public health hazard. The occurrences of toxic HAB are unpredictable and highly spatially and temporary variable in freshwater ecosystems. To study the abiotic drivers for toxic HAB, a floating research station has been deployed in a hyper-eutrophic lake in Madison Lake, Minnesota, from June-October 2016. This research station provides full depth water quality (hourly) and meteorological monitoring (5 minutes). Water quality monitoring is performed by an autonomously traversed water quality sonde that provides chemical, physical and biological measurements; including phycocyanin, a photosynthetic pigment distinct to cyanobacteria. A bloom of cyanobacteria recorded in the epiliminion in mid-July was driven by prolonged strong thermal stratification in the water column, high surface water temperatures and high phosphate concentrations in the epiliminion. The high biovolume (BV) persisted until late September and was sustained below the surface after stratification weakened, when the thermocline did not confine cyanobacteria-rich layers any more, and cyanobacteria vertical heterogeneities decayed in the water column. High correlations among BV stratification, surface water temperature, and stratification stability informed the development of a quantitative relationship to determine how BV heterogeneities vary with thermal structure in the water column. The BV heterogeneity decreased with thermal stratification stability and surface water temperature, and the dynamic lake stability described by the Lake Number. Finally the location of maximum BV accumulation showed diurnal patterns ie. BV peaks were observed at 1 m depth during the day and deeper layers during the night, which followed patterns in light penetration and thermocline depth. These findings capture cyanobacteria vertical and temporal heterogeneities on a on

  12. Evaluation of 25 Y of environmental monitoring data around Madras atomic power station (MAPS), Kalpakkam (India)

    International Nuclear Information System (INIS)

    Rajaram, S.; Brindha, J. T.; Sreedevi, K. R.; Manu, A.; Thilakavathi, A.; Ramkumar, S.; Santhanakrishnan, V.; Balagurunathan, M. R.; Jesan, T.; Kannan, V.; Hegde, A. G.

    2010-01-01

    The Environmental Survey Laboratory at Kalpakkam (India) carries out elaborate monitoring programme involving atmospheric, terrestrial and aquatic samples for radioactivity to evaluate the impact of operating two pressurised heavy water reactors. This paper presents the evaluation of 25 y (1983-2008) data. Statistical analysis of the environmental data for different radionuclides showed that the data best fits log-normal distribution. The data analysed showed that fission products such as 137 Cs, 90 Sr and 131 I were due to global fallout only. A ratio of 0.2 was obtained for 90 Sr to 137 Cs in air filter samples, only during Chernobyl accident period. The transfer factor of 137 Cs and 90 Sr for rice was computed to be 0.23 and 0.03 and vegetables 0.25 and 0.10, respectively. Activation products 3 H and 41 Ar are the only radionuclides that are related to MAPS operation. A strong correlation (r = 0.9) was observed between 3 H activity in air and 3 H discharged to the atmosphere. A similar correlation (r = 0.8) was observed in 3 H concentration in seawater and 3 H discharged in the liquid waste. The annual internal dose due to 3 H and annual external dose due to 41 Ar evaluated in the last 25 y show that the members of the public received less than 2% of the dose limit (1 mSv y -1 ) set by ICRP 72. (authors)

  13. The use of cadmium telluride γ spectrometers in monitoring activity deposited in nuclear power stations

    International Nuclear Information System (INIS)

    Jones, L.T.

    1977-01-01

    The ability to inspect and test key components and when necessary repair or replace them is a significant factor in the safety case submitted before consent is given for construction of a nuclear reactor. A knowledge of the probable rate of deposition and isotopic composition of radioactive contamination in these areas is necessary and since it is not always practicable to take samples away to the laboratory for analysis, direct gamma ray spectroscopy in the contaminated environment is sometimes used. The experience of direct monitoring with a cadmium telluride spectrometer in two such reactor situations is reported. In the first situation, a remotely cooled intrinsic Germanium spectrometer was used in equivalent positions and spectra from both systems are presented. The relative merits of the two systems are discussed. In the second situation, measurements were made in an environment at 70 deg C in radiation levels of 10Rh -1 . An improvised cooling system was used to maintain the Cadmium Telluride at about 20 deg C and Pile-up Rejection was used to enable count rates of about 10 5 s -1 to be handled. It is noted that the usually quoted detector parameters, resolution and crystal volume, are not necessarily the most important in practical spectrometry of mixed isotopes. As with germanium detectors, the most useful parameter is probably the Peak-to-Compton ratio

  14. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    International Nuclear Information System (INIS)

    Stellwag, B.; Aaltonen, P.; Hickling, J.

    1997-01-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ''on-line'' and ''in-situ'' characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. For confirmation, a complete set of sensors

  15. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Stellwag, B [Siemens AG Unternehmensbereich KWU, Erlangen (Germany); Aaltonen, P [Technical Research Centre of Finland, Espoo (Finland); Hickling, J [CML GmbH, Erlangen (Germany)

    1997-02-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ``on-line`` and ``in-situ`` characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. (Abstract Truncated)

  16. MONITORING AND CONTROLLING ON SURFACE SETTLEMENT IN SAND AND GRAVEL STRATA CAUSED BY SUBWAY STATION CONSTRUCTION APPLYING PIPE-ROOF PRE-CONSTRUCTION METHOD (PPM

    Directory of Open Access Journals (Sweden)

    Xian Yang

    2017-07-01

    Full Text Available Pipe-roof Pre-construction Method (PPM is regarded as a safer method to construct underground space, especially suitable for the construction sites with dense surface buildings, underground pipelines and complicated geological conditions. Xinleyizhi Station of Shenyang Metro constructed by PPM. In order to ensure safety in construction, the whole construction process was closely monitored. In this paper, monitoring results of surface settlement in PPM is analyzed. According to the monitoring results, the most serious settlement occurred in pipes jacking, which was the first and the most crucial step in PPM. The settlement reasons in each step are discussed, and controlling methods of surface settlement in each step are elaborated. Through close monitoring and timely control, the construction of Xinleyizhi Station completed smoothly. Because of the obvious advantages of PPM, the method will be used more widely in construction of shallow buried excavation under complicated surrounding and geological conditions.

  17. Safety analysis report: A comparison of incidents from Safety Years 2006 through 2010, USDA Forest Service, Rocky Mountain Research Station Inventory and Monitoring Program

    Science.gov (United States)

    Devon Donahue

    2012-01-01

    This paper is an analysis of 5 years of accident data for the USDA Forest Service, Rocky Mountain Research Station (RMRS) Inventory and Monitoring (IM) Program that identifies past trends, allows for standardized self-comparison, and increases our understanding of the true costs of injuries and accidents. Measuring safety is a difficult task. While most agree that...

  18. Expert Water Quality Panel Review of Responses to the NASA Request for Information for the International Space Station On-Board Environmental Monitoring System

    Science.gov (United States)

    Fishman, Julianna L.; Mudgett, Paul D.; Packham, Nigel J.; Schultz, John R.; Straub, John E., II

    2005-01-01

    On August 9, 2003, NASA, with the cooperative support of the Vehicle Office of the International Space Station Program, the Advanced Human Support Technology Program, and the Johnson Space Center Habitability and Environmental Factors Office released a Request for Information, or RFI, to identify next-generation environmental monitoring systems that have demonstrated ability or the potential to meet defined requirements for monitoring air and water quality onboard the International Space Station. This report summarizes the review and analysis of the proposed solutions submitted to meet the water quality monitoring requirements. Proposals were to improve upon the functionality of the existing Space Station Total Organic Carbon Analyzer (TOCA) and monitor additional contaminants in water samples. The TOCA is responsible for in-flight measurement of total organic carbon, total inorganic carbon, total carbon, pH, and conductivity in the Space Station potable water supplies. The current TOCA requires hazardous reagents to accomplish the carbon analyses. NASA is using the request for information process to investigate new technologies that may improve upon existing capabilities, as well as reduce or eliminate the need for hazardous reagents. Ideally, a replacement for the TOCA would be deployed in conjunction with the delivery of the Node 3 water recovery system currently scheduled for November 2007.

  19. A volatile organics concentrator for use in monitoring Space Station water quality

    Science.gov (United States)

    Ehntholt, Daniel J.; Bodek, Itamar; Valentine, James R.; Trabanino, Rudy; Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    The process used to identify, select, and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is discerned. The trade analysis leading to the recommended volatile organics concentrator (VOC) concept to be tested in a breadboard device is presented. The system covers the areas of gases, volatile separation from water, and water removal/gas chromatograph/mass spectrometer interface. Five options for potential use in the VOC and GC/MS system are identified and ranked, and also nine options are presented for separation of volatiles from the water phase. Seven options for use in the water removal/GC column and MS interface are also identified and included in the overall considerations. A final overall recommendation for breadboard VOC testing is given.

  20. Analysis of technological innovation in Danish wind turbine industry - including the Test Station for Windturbines dual roll as research institution and certification authority

    International Nuclear Information System (INIS)

    Dannemand Andersen, P.

    1993-01-01

    The overall aim of this thesis is to examine the interactions between the Danish wind turbine industry and the Test Station for Wind Turbines. Because these interactions are concerning technological innovation, it follows that the innovation processes within the enterprises must be analyzed and modelled. The study is carried out as an iterative model-developing process using case study methods. The findings from some less structured interviews are discussed with literature and forms a basis for models and new interviews. The thesis is based on interviews with 20 R and D engineers in the Danish wind turbine industry, 7 engineers at The Test Station and 7 people involved in wind power abroad (American and British). The theoretical frame for this thesis is sociology/organizational theory and industrial engineering. The thesis consists of five main sections, dealing with technology and knowledge, innovation processes, organizational culture, innovation and interaction between the Test Station's research activities and the companies' innovation processes, and finally interaction through the Test Stations certification activity. First a taxonomy for technology and knowledge is established in order to clarify what kind of technology the interactions are all about, and what kind of knowledge is transferred during the interactions. This part of the thesis also contains an analysis of the patents drawn by the Danish wind turbine industry. The analysis shows that the Danish wind turbine industry do not use patents. Instead the nature of the technology and the speed of innovation are used to protect the industry's knowledge. (EG) (192 refs.)

  1. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS

    Directory of Open Access Journals (Sweden)

    Berger Thomas

    2016-01-01

    Full Text Available The radiation environment encountered in space differs in nature from that on Earth, consisting mostly of highly energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones present on Earth for occupational radiation workers. Since the beginning of the space era, the radiation exposure during space missions has been monitored with various active and passive radiation instruments. Also onboard the International Space Station (ISS, a number of area monitoring devices provide data related to the spatial and temporal variation of the radiation field in and outside the ISS. The aim of the DOSIS (2009–2011 and the DOSIS 3D (2012–ongoing experiments was and is to measure the radiation environment within the European Columbus Laboratory of the ISS. These measurements are, on the one hand, performed with passive radiation detectors mounted at 11 locations within Columbus for the determination of the spatial distribution of the radiation field parameters and, on the other, with two active radiation detectors mounted at a fixed position inside Columbus for the determination of the temporal variation of the radiation field parameters. Data measured with passive radiation detectors showed that the absorbed dose values inside the Columbus Laboratory follow a pattern, based on the local shielding configuration of the radiation detectors, with minimum dose values observed in the year 2010 of 195–270 μGy/day and maximum values observed in the year 2012 with values ranging from 260 to 360 μGy/day. The absorbed dose is modulated by (a the variation in solar activity and (b the changes in ISS altitude.

  2. Fisheries research and monitoring activities of the Lake Erie Biological Station, 2014

    Science.gov (United States)

    Bodamer Scarbro, Betsy L.; Edwards, William; Gawne, Carrie; Kocovsky, Patrick M.; Kraus, Richard T.; Rogers, Mark W.; Stewart, Taylor

    2015-01-01

    In 2014, the USGS LEBS successfully completed large vessel surveys in all three of Lake Erie’s basins. Lake Erie Biological Station’s primary vessel surveys included the Western Basin Forage Fish Assessment and East Harbor Forage Fish Assessment as well as contributing to the cooperative multi-agency Central Basin Hydroacoustics Assessment, the Eastern Basin Coldwater Community Assessment, and LTLA (see FTG, CWTG, and FTG reports, respectively). Results from the surveys contribute to Lake Erie Committee Task Group data needs and analyses of trends in Lake Erie’s fish communities. The cruise survey schedule in 2014 was greatly increased by LEBS’s participation in the Lake Erie CSMI, which consisted of up-to two weeks of additional sampling per month from April to October. CSMI is a bi-national effort that occurs at Lake Erie every five years with the purpose of addressing data and knowledge gaps necessary to management agencies and the Lake Erie LaMP. LEBS deepwater science capabilities also provided a platform for data collection by Lake Erie investigators from multiple agencies and universities including: the USGS GLSC, ODW, KSU, OSU, UM, PU, UT, and the USNRL. Samples from this survey are being processed and a separate report of the findings will be made available in a separate document. Our 2014 vessel operations were initiated in mid-April, as soon after ice-out as possible, and continued into early December. During this time, crews of the R/V Muskie and R/V Bowfin deployed 196 bottom trawls covering 48.5 km of lake-bottom, nearly 6 km of gillnet, collected data from 60 hydroacoustics transects, 285 lower trophic (i.e., zooplankton and benthos) samples, and 330 water quality measures (e.g., temperature profiles, water samples). Thus, 2014 was an intensive year of field activity. Our June and September bottom trawl surveys in the Western Basin were numerically dominated by Emerald Shiner, White Perch, and Yellow Perch; however, Freshwater Drum were

  3. A system for radiation monitoring at the site for emergency planning and response in a nuclear station potentialities and prospects

    International Nuclear Information System (INIS)

    Novakov, V.; Moskovska, N.; Madzharov, M.; Angelov, V.

    1993-01-01

    The paper describes the existing system for radiation monitoring of the NPP region. The location of the devices puts a number of problems as maintenance of the radiometric equipment and urgent collecting and processing of the measuring data. Undeniably, to get an effective and timely decision, it is necessary to have on hand information as complete and prompt as possible, about the radiological situation in the regions, towns, villages and sites. As a result of daily observation and registration, an amount of enough in volume data could be accumulated. This data may be used as a base in case of a sudden change of the radiological situation and/or in case of arising of some local contaminations as a result of a volley type of emission, accidents at the nuclear power stations and releases fractions of radioactive and rare gases. The data obtained for a comparatively large region (about 700 square kilometers) with a high degree of gamma detectors distribution density are discussed. In the conditions of a progressively complicating radiological situation, they allow to determine the possible directions of the emission and also to undertake some response actions for protection of the population in time. (author)

  4. OLDES - an on-line dose evaluation system that can be integrated into the remote monitoring system of nuclear power stations for additional monitoring and prognostic assessment in case of major accidental activity release

    International Nuclear Information System (INIS)

    Witt, H. de; Brenk, H.D.; Kruschel, K.P.; Knaup, A.G.

    1986-01-01

    Remote monitoring systems are an inherent part of the environmental surveillance installations of most commercial LWR power plants in the FRG. The systems are designed to cover routine and accident situations. They provide meteorological data, gross effluent dose rates, and dose measurements at approximately 25 locations in the vicinity of the plant in time steps of 10 minutes. Based on such a network, an attempt has been made to develop an on-line dose evaluation system (OLDES) as a tool to aid decision making processes in case of major accidental releases. On-line, here means that the software package directly includes the measurements at the monitoring stations in order to adjust the dose computations to the measurements in time steps of 10 minutes. In this way the system yields the best possible bases, both for actual diagnosis of radiation exposure, and for dose projections. The software package uses a Gaussian puff trajectory model to simulate atmospheric dispersion and deposition of radionuclides. It includes 'cloud- and ground-shine irradiation' and allows for changing weather conditions without exceeding the limits of real time calculation. Preliminary tests of the software package revealed reasonable semioperational performance. (orig.)

  5. Simulations of the neutron energy-spectra at the Olympus Gate Environmental Monitoring Station due to historical Bevatron operations

    International Nuclear Information System (INIS)

    Donahue, R.J.; Thomas, R.H.; Zeman, G.H.

    2001-01-01

    Offsite neutron fluences resulting from Bevatron operations reached a maximum in 1959, prior to the addition of a permanent concrete roof shield, which was constructed in 1962. From the first operation of the Bevatron measurements of neutron fluence were made at locations around the perimeter of the Lawrence Berkeley National Laboratory (LBNL) campus. Since the late 1950's measurements made at several locations, and particularly at the site of what is now called the Olympus Gate Environmental Monitoring Station, have been routinely reported and published. Early measurements were used to establish the shape of the neutron-energy spectrum from which an energy-averaged fluence-to-dose equivalent conversion coefficient could be derived. This conversion coefficient was then applied to a measured total neutron fluence to obtain the appropriate dose equivalent quantity required by regulation. Recent work by Thomas et al. (2000) have compared the early conversion coefficients used in the sixties with those accepted today and suggest suggested that ''the dose equivalents reported in the late fifties and early sixties were conservative by factors between two and four. In any current review of the historical data, therefore it would be prudent to reduce the reported dose equivalents by at least a factor of two.'' However, that analysis was based on the ''state of the art'' neutron energy-spectra of the '60s. This paper provides a detailed knowledge of the neutron energy spectrum at the site boundary paper thus removing any uncertainty in the analysis of Thomas et al., which might be caused by the use of the early neutron energy-spectra. Detailed Monte Carlo analyses of the interactions of 6.2 GeV protons in thick, medium-A targets are described. In the computer simulations, neutrons produced were allowed to scatter in the atmosphere. Detailed neutron energy spectra were calculated at a distance and elevation corresponding to the location of the Olympus Gate EMS. Both older

  6. Long open-path TDL based system for monitoring the background concentration for deployment at Jungfraujoch High Altitude Research Station- Switzerland

    Science.gov (United States)

    Simeonov, V.; van den Bergh, H.; Parlange, M. B.

    2009-12-01

    A new long-open-path instrument developed at EPFL for methane and water vapor observation will be presented. The instrument is developed and will be used within the GAW+ CH program and aims at long-term monitoring of background methane concentration at the High Altitude Research Station Jungfraujoch (3580 mASL). The instrument is built on the monostatic scheme (transceiver -distant retroreflector) using a 1.65 nm tunable diode laser (TDL) and a retroreflector at 1200 m from the transceiver. The data will be compared with in-situ measurements to evaluate the effect of the station on the in-situ data.

  7. Contaminants and nutrients in variable sea areas (Canvas). Application of automatic monitoring stations in the German marine environment

    International Nuclear Information System (INIS)

    Nies, H.; Bruegge, B.; Sterzenbach, D.; Knauth, H.D.; Schroeder, F.

    1999-01-01

    Permanent observation of parameters at sea stations can only be obtained by automatic sampling. The MERMAID technique developed in former projects provides a possibility to run automatic stations within the German MARNET measuring stations to obtain data on nutrients concentration on line and to collect organic micropollutants and the radionuclide 137 Cs by solid phase extraction from seawater and subsequent analysis in the laboratory. The BSH MARNET consists of ten stations located in the German Bight sector of the North Sea and the western Baltic. First results from the time series of nutrient and organic micropollutant concentrations has been presented

  8. Monitoring of volatile organic compounds (VOCs) from an oil and gas station in northwest China for 1 year

    Science.gov (United States)

    Zheng, Huang; Kong, Shaofei; Xing, Xinli; Mao, Yao; Hu, Tianpeng; Ding, Yang; Li, Gang; Liu, Dantong; Li, Shuanglin; Qi, Shihua

    2018-04-01

    Oil and natural gas are important for energy supply around the world. The exploring, drilling, transportation and processing in oil and gas regions can release a lot of volatile organic compounds (VOCs). To understand the VOC levels, compositions and sources in such regions, an oil and gas station in northwest China was chosen as the research site and 57 VOCs designated as the photochemical precursors were continuously measured for an entire year (September 2014-August 2015) using an online monitoring system. The average concentration of total VOCs was 297 ± 372 ppbv and the main contributor was alkanes, accounting for 87.5 % of the total VOCs. According to the propylene-equivalent concentration and maximum incremental reactivity methods, alkanes were identified as the most important VOC groups for the ozone formation potential. Positive matrix factorization (PMF) analysis showed that the annual average contributions from natural gas, fuel evaporation, combustion sources, oil refining processes and asphalt (anthropogenic and natural sources) to the total VOCs were 62.6 ± 3.04, 21.5 ± .99, 10.9 ± 1.57, 3.8 ± 0.50 and 1.3 ± 0.69 %, respectively. The five identified VOC sources exhibited various diurnal patterns due to their different emission patterns and the impact of meteorological parameters. Potential source contribution function (PSCF) and concentration-weighted trajectory (CWT) models based on backward trajectory analysis indicated that the five identified sources had similar geographic origins. Raster analysis based on CWT analysis indicated that the local emissions contributed 48.4-74.6 % to the total VOCs. Based on the high-resolution observation data, this study clearly described and analyzed the temporal variation in VOC emission characteristics at a typical oil and gas field, which exhibited different VOC levels, compositions and origins compared with those in urban and industrial areas.

  9. Human factors issues and approaches in the spatial layout of a space station control room, including the use of virtual reality as a design analysis tool

    Science.gov (United States)

    Hale, Joseph P., II

    1994-01-01

    Human Factors Engineering support was provided for the 30% design review of the late Space Station Freedom Payload Control Area (PCA). The PCA was to be the payload operations control room, analogous to the Spacelab Payload Operations Control Center (POCC). This effort began with a systematic collection and refinement of the relevant requirements driving the spatial layout of the consoles and PCA. This information was used as input for specialized human factors analytical tools and techniques in the design and design analysis activities. Design concepts and configuration options were developed and reviewed using sketches, 2-D Computer-Aided Design (CAD) drawings, and immersive Virtual Reality (VR) mockups.

  10. Study of the Cherokee Nuclear Station: projected impacts, monitoring plan, and mitigation options for Cherokee County, South Carolina

    International Nuclear Information System (INIS)

    Peelle, E.; Schweitzer, M.; Scharre, P.; Pressman, B.

    1979-07-01

    This report inventories Cherokee County's capabilities and CNS project characteristics, projects expected impacts from the interaction of the two defines four options for Cherokee County decision makers, and presents a range of possible mitigation and monitoring plans for dealing with the problems identified. The four options and general implementation guidelines for each are presented after reviewing pertinent features of other mitigation and monitoring plans. The four options include (1) no action, (2) preventing impacts by preventing growth, (3) selective growth in designated areas as services can be supplied, and (4) maximum growth designed to attract as many in-movers as possible through a major program of capital investiments in public and private services. With the exception of the no action option, all plans deal with impacts according to some strategy determined by how the County wishes to manage growth. Solutions for impact problems depend on which growth strategy is selected and what additional resources are secured during the impact period. A monitoring program deals with the problems of data and projections uncertainty, while direct action is proposed to deal with the institutional problems of delay of the needed access road, timeing and location problems from the tax base mismatch, and lack of local planning capability

  11. Study of the Cherokee Nuclear Station: projected impacts, monitoring plan, and mitigation options for Cherokee County, South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Peelle, E.; Schweitzer, M.; Scharre, P.; Pressman, B.

    1979-07-01

    This report inventories Cherokee County's capabilities and CNS project characteristics, projects expected impacts from the interaction of the two defines four options for Cherokee County decision makers, and presents a range of possible mitigation and monitoring plans for dealing with the problems identified. The four options and general implementation guidelines for each are presented after reviewing pertinent features of other mitigation and monitoring plans. The four options include (1) no action, (2) preventing impacts by preventing growth, (3) selective growth in designated areas as services can be supplied, and (4) maximum growth designed to attract as many in-movers as possible through a major program of capital investiments in public and private services. With the exception of the no action option, all plans deal with impacts according to some strategy determined by how the County wishes to manage growth. Solutions for impact problems depend on which growth strategy is selected and what additional resources are secured during the impact period. A monitoring program deals with the problems of data and projections uncertainty, while direct action is proposed to deal with the institutional problems of delay of the needed access road, timeing and location problems from the tax base mismatch, and lack of local planning capability.

  12. External gamma radiation monitoring in the environs of Kaiga Generating Station (KGS), using thermoluminescent dosimeters, during the period 1989-2003

    International Nuclear Information System (INIS)

    Basu, A.S.; Chougaonkar, M.P.; Mayya, Y.S.; Puranik, V.D.; Reji, T.K.; Ravi, P.M.; Hegde, A.G.

    2005-05-01

    This publication reports the results of external gamma radiation monitoring using Thermoluminescent Dosimeters (TLDs), in the environs of Kaiga Generating Station (KGS) during its preoperational survey between October 1989 and June 1998. The report also presents quarterly and annual values of air dose during the operational phase of the station between July 1998 and Dec. 2003 around the environmcnt of KGS. The results of TLD analysis, during the period October 1989-June 1998, indicate that the average annual air dose for the locations monitored, was 502± 91 μGy/a. The general background of the environs around Kaiga during the operational period, i.e. July 1998 and Dec. 2003, between 2.3 km. to 32km. has been found to be 509±74 μGy/a. The report discusses the methodology and different analyses carried out. (author)

  13. The NRPI multi-purpose on-line monitoring station for measurement of natural radioactivity in the ambient atmosphere and in the soil

    International Nuclear Information System (INIS)

    Jilek, K.; Slezakova, M.; Fronka, A.; Prokop, T.; Neubauer, L.

    2017-01-01

    During years 2010 12 an automated, on-line and wireless outdoor measurement station of atmospheric radon, gamma dose rate and meteorological parameters was realised at the National Radiation Protection Institute (NRPI) in Prague. At the turn of the year 2013 an expansion of the existing station was completed. Under the project funded by the Czech Technological Agency a new updated station was established, additionally equipped with modules for measurement of atmospheric radon/thoron short-lived decay products, radon in water and soil and radon exhalation rate from soil. After the introduction of the station updated key detection parameters and benefits, its use for atmospheric modelling and monitoring is demonstrated. There are summarised results from the 3-year measurement period in the NRPI outdoor area in Prague and from simultaneous annual measurement performed by another similar station located near uranium mud fields in DIAMO, state enterprise, Straz pod Ralskem. Observed seasonal and diurnal variations of atmospheric radon concentrations and variability of the equilibrium factor, F, are illustrated and compared. (authors)

  14. Technical evaluation report on the monitoring of electric power to the reactor-protection system for the Pilgrim Nuclear Power Station

    International Nuclear Information System (INIS)

    Selan, J.C.

    1982-01-01

    This report documents the technical evaluation of the monitoring of electric power to the reactor protection system (RPS) at the Pilgrim Nuclear Power Station. The evaluation is to determine if the proposed design modification will protect the RPS from abnormal voltage and frequency conditions which could be supplied from the power supplies and will meet certain requirements set forth by the Nuclear Regulatory Commission. The proposed design modifications will protect the RPS from sustained abnormal voltage and frequency conditions from the supplying sources

  15. Monitoring the Microgravity Environment Quality On-board the International Space Station Using Soft Computing Techniques. Part 2; Preliminary System Performance Results

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.; Weiss, Daniel S.

    2002-01-01

    This paper presents the preliminary performance results of the artificial intelligence monitoring system in full operational mode using near real time acceleration data downlinked from the International Space Station. Preliminary microgravity environment characterization analysis result for the International Space Station (Increment-2), using the monitoring system is presented. Also, comparison between the system predicted performance based on ground test data for the US laboratory "Destiny" module and actual on-orbit performance, using measured acceleration data from the U.S. laboratory module of the International Space Station is presented. Finally, preliminary on-orbit disturbance magnitude levels are presented for the Experiment of Physics of Colloids in Space, which are compared with on ground test data. The ground test data for the Experiment of Physics of Colloids in Space were acquired from the Microgravity Emission Laboratory, located at the NASA Glenn Research Center, Cleveland, Ohio. The artificial intelligence was developed by the NASA Glenn Principal Investigator Microgravity Services Project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment of time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a dynamic graphical display, implemented in Java, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, structural modes, etc., and decide whether or not to run their experiments, whenever that is an option, based on the acceleration magnitude and frequency sensitivity associated with that experiment. This monitoring system detects primarily the vibratory disturbance sources. The system has built-in capability to detect both known

  16. Proceedings of the international symposium on environmental monitoring and dose estimation of residents after accident of TEPCO's Fukushima Daiichi Nuclear Power Stations

    International Nuclear Information System (INIS)

    Takahashi, Sentaro; Yamana, Hajimu; Takahashi, Tomoyuki; Takamiya, Koichi; Fukutani, Satoshi; Sato, Nobuhiro; Nakatani, Maki

    2013-02-01

    In March 2011, a massive earthquake and the resulting tsunami struck the Tohoku area in Japan, causing serious damages to TEPCO's Fukushima Daiichi nuclear plant and the release of a significant quantity of radionuclides into the surrounding environment. This accident underlined the necessity of establishing new and comprehensive scientific research for promoting safety in nuclear technology. With this aim, the Kyoto University Research Reactor Institute (KURRI) developed a new research program called the “KUR Research Program for Scientific Basis of Nuclear Safety” from this year. In this program, we are planning to hold an annual series of international symposiums along with many other research activities. The first in this series of symposiums, entitled “The International Symposium on Environmental Monitoring and Dose Estimation of Residents after Accident of TEPCO's Fukushima Daiichi Nuclear Power Station,” deals with the radiological effect of the March 2011 accident in Fukushima Daiichi NPP on the public. The purpose of this symposium is to collate data on environmental radioactivity anadiation dose in residents, discuss and verify these data, and clarify the actual situation of environmental contamination anesultant radiation exposed to the residents. We believe that an accurate estimation of the radiation dose is quite essential for planning for the healthy life and mental contentment of the residents, and we hope that many researchers who are studying the radiological effects of the accident will join us for these purposes. The environmental monitoring data are important for the dose assessment for residents. However, the monitoring data in the early stage are not sufficient for dose assessment, particularly near the NPP site, because of the confusion and blackout caused by the earthquake. However, many researchers and organizations in Japan and other countries have independently carried out radiation monitoring. We believe that the publication and

  17. One Year of Monthly N and O Isotope Measurements in Nitrate from 18 Streamwater Monitoring Stations Within the Predominantly Pastoral Upper Manawatu Catchment, New Zealand

    Science.gov (United States)

    Baisden, W. T.; Douence, C.

    2010-12-01

    New Zealand's intensive pastoral agricultural systems have a significant impact on water quality due to nitrogen loading in rivers. A research programme has been designed to develop indicators of the sources and denitrification losses of nitrate in streamwater. This work describes the results of one year of monthly measurements at ~18 monitoring locations in the 1260 square km upper Manawatu River catchment. The catchment was chosen for study because it is among the most pastoral catchments in New Zealand, with little non-pastoral agriculture and limited forest area outside of the Tararua mountain range on the west side of the catchment. The use of N and O isotope ratios in nitrate has considerable potential to elucidate the sources and fate of nitrate with greater precision than in most other nations due to the lack of nitrate in atmospheric deposition and the lack of nitrates used as fertilizer. We measured N and O isotope ratios in nitrate plus nitrite using cadmium and azide chemical denitrification method, and refer to the results as nitrate for brevity due to low nitrite concentrations. When examined as annual averages at each monitoring site, we found the lowest N and O isotope ratios in our only site draining native forest. All agricultural monitoring sites sit approximately on a 1:1 line, enriched in N-15 and O-18 by 2-6 per mil relative to the native forest subcatchment. The three main effluent point sources in the catchment demonstrated unexpected variability in isotope ratios. Two modern sewage treatment ponds had N and O isotope ratios close to those found in agricultural catchments, while a closed meat freezing factory effluent pond had isotope ratios strongly enriched in N-15 and O-18. The lack of summer low flows during monitoring period, combined with the variability in isotope ratios from point source, appeared to be responsible for our inability to clearly detect the effect of point sources in the isotope data from stations upstream and

  18. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Hawaiian Archipelago since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Hawaiian...

  19. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Mariana Archipelago in 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Mariana...

  20. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Mariana Archipelago in 2014 (NCEI Accession 0157759)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Mariana...

  1. The new Mediterranean background monitoring station of Ersa, Cape Corsica: A long term Observatory component of the Chemistry-Aerosol Mediterranean Experiment (ChArMEx)

    Science.gov (United States)

    Dulac, Francois

    2013-04-01

    The Chemistry-Aerosol Mediterranean Experiment (ChArMEx, http://charmex.lsce.ipsl.fr/) is a French initiative supported by the MISTRALS program (Mediterranean Integrated Studies at Regional And Locals Scales, http://www.mistrals-home.org). It aims at a scientific assessment of the present and future state of the atmospheric environment in the Mediterranean Basin, and of its impacts on the regional climate, air quality, and marine biogeochemistry. The major stake is an understanding of the future of the Mediterranean region in a context of strong regional anthropogenic and climatic pressures. The target of ChArMEx is short-lived particulate and gaseous tropospheric trace species which are the cause of poor air quality events, have two-way interactions with climate, or impact the marine biogeochemistry. In order to fulfill these objectives, important efforts have been put in 2012 in order to implement the infrastructure and instrumentation for a fully equipped background monitoring station at Ersa, Cape Corsica, a key location at the crossroads of dusty southerly air masses and polluted outflows from the European continent. The observations at this station began in June 2012 (in the context of the EMEP / ACTRIS / PEGASOS / ChArMEx campaigns). A broad spectrum of aerosol properties is also measured at the station, from the chemical composition (off-line daily filter sampling in PM2.5/PM10, on-line Aerosol Chemical Speciation Monitor), ground optical properties (extinction/absorption/light scattering coeff. with 1-? CAPS PMex monitor, 7-? Aethalometer, 3-? Nephelometer), integrated and vertically resolved optical properties (4-? Cimel sunphotometer and LIDAR, respective), size distribution properties (N-AIS, SMPS, APS, and OPS instruments), mass (PM1/PM10 by TEOM/TEOM-FDMS), hygroscopicity (CCN), as well as total insoluble deposition. So far, real-time measurement of reactive gases (O3, CO, NO, NO2), and off-line VOC measurements (cylinders, cartridges) are also

  2. Development of elements of the condition monitoring system of turbo generators of thermal power stations and nuclear power plants

    Science.gov (United States)

    Kumenko, A. I.; Kostyukov, V. N.; Kuz'minykh, N. Yu.; Boichenko, S. N.; Timin, A. V.

    2017-08-01

    The rationale is given for the improvement of the regulatory framework for the use of shaft sensors for the in-service condition monitoring of turbo generators and the development of control systems of shaft surfacing and misalignments of supports. A modern concept and a set of methods are proposed for the condition monitoring of the "shaft line-thrust bearing oil film-turbo generator supports" system elements based on the domestic COMPACS® technology. The system raw data are design, technology, installation, and operating parameters of the turbo generator as well as measured parameters of the absolute vibration of supports and mechanical quantities, relative displacements and relative vibration of the rotor teeth in accordance with GOST R 55263-2012. The precalculated shaft line assembly line in the cold state, the nominal parameters of rotor teeth positions on the dynamic equilibrium curve, the static and dynamic characteristics of the oil film of thrust bearings, and the shaft line stiffness matrix of unit support displacements have been introduced into the system. Using the COMPACS-T system, it is planned to measure positions and oscillations of rotor teeth, to count corresponding static and dynamic characteristics of the oil film, and the static and dynamic loads in the supports in real time. Using the obtained data, the system must determine the misalignments of supports and corrective alignments of rotors of coupling halves, voltages in rotor teeth, welds, and bolts of the coupling halves, and provide automatic conclusion if condition monitoring parameters correspond to standard values. A part of the methodological support for the proposed system is presented, including methods for determining static reactions of supports under load, the method for determining shaft line stiffness matrices, and the method for solving the inverse problem, i.e., the determination of the misalignments of the supports by measurements of rotor teeth relative positions in bearing

  3. A luciferase-based assay for rapid assessment of drug activity against Mycobacterium tuberculosis including monitoring of macrophage viability.

    Science.gov (United States)

    Larsson, Marie C; Lerm, Maria; Ängeby, Kristian; Nordvall, Michaela; Juréen, Pontus; Schön, Thomas

    2014-11-01

    The intracellular (IC) effect of drugs against Mycobacterium tuberculosis (Mtb) is not well established but increasingly important to consider when combining current and future multidrug regimens into the best possible treatment strategies. For this purpose, we developed an IC model based on a genetically modified Mtb H37Rv strain, expressing the Vibrio harvei luciferase (H37Rv-lux) infecting the human macrophage like cell line THP-1. Cells were infected at a low multiplicity of infection (1:1) and subsequently exposed to isoniazid (INH), ethambutol (EMB), amikacin (AMI) or levofloxacin (LEV) for 5days in a 96-well format. Cell viability was evaluated by Calcein AM and was maintained throughout the experiment. The number of viable H37Rv-lux was determined by luminescence and verified by a colony forming unit analysis. The results were compared to the effects of the same drugs in broth cultures. AMI, EMB and LEV were significantly less effective intracellularly (MIC90: >4mg/L, 8mg/L and 2mg/L, respectively) compared to extracellularly (MIC90: 0.5mg/L for AMI and EMB; 0.25mg/L for LEV). The reverse was the case for INH (IC: 0.064mg/L vs EC: 0.25mg/L). In conclusion, this luciferase based method, in which monitoring of cell viability is included, has the potential to become a useful tool while evaluating the intracellular effects of anti-mycobacterial drugs. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Assessment of wind speed and wind power through three stations in Egypt, including air density variation and analysis results with rough set theory

    International Nuclear Information System (INIS)

    Essa, K.S.M.; Embaby, M.; Marrouf, A.A.; Koza, A.M.; Abd El-Monsef, M.E.

    2007-01-01

    It is well known that the wind energy potential is proportional to both air density and the third power of the wind speed average over a suitable time period. The wind speed and air density have random variables depending on both time and location. The main objective of this work is to derive the most general wind energy potential of the wind formulation putting into consideration the time variable in both wind speed and air density. The correction factor is derived explicitly in terms of the cross-correlation and the coefficients of variation.The application is performed for environmental and wind speed measurements at the Cairo Airport, Kosseir and Hurguada, Egypt. Comparisons are made between Weibull, Rayleigh, and actual data distributions of wind speed and wind power of one year 2005. A Weibull distribution is the best match to the actual probability distribution of wind speed data for most stations. The maximum wind energy potential was 373 W/m 2 in June at Hurguada (Red Sea coast) where the annual mean value was 207 W/m 2 . By Using Rough Set Theory, We Find That the Wind Power Depends on the Wind Speed with greater than air density

  5. Guidelines for Learning Stations.

    Science.gov (United States)

    Fehrle, Carl C.; Schulz, Jolene

    Guidelines for designing and planning learning stations for pupils at the elementary grade level include suggestions on how to develop a station that will be successful in meeting the learners' needs. Instructions for the use of tapes at a station and matching pupils with stations are given, as are guidelines on classroom arrangement and record…

  6. A home monitoring program including real-time wireless home spirometry in idiopathic pulmonary fibrosis: a pilot study on experiences and barriers.

    Science.gov (United States)

    Moor, C C; Wapenaar, M; Miedema, J R; Geelhoed, J J M; Chandoesing, P P; Wijsenbeek, M S

    2018-05-29

    In idiopathic pulmonary fibrosis (IPF), home monitoring experiences are limited, not yet real-time available nor implemented in daily care. We evaluated feasibility and potential barriers of a new home monitoring program with real-time wireless home spirometry in IPF. Ten patients with IPF were asked to test this home monitoring program, including daily home spirometry, for four weeks. Measurements of home and hospital spirometry showed good agreement. All patients considered real-time wireless spirometry useful and highly feasible. Both patients and researchers suggested relatively easy solutions for the identified potential barriers regarding real-time home monitoring in IPF.

  7. Microbial Monitoring from the Frontlines to Space: Department of Defense Small Business Innovation Research Technology Aboard the International Space Station

    Science.gov (United States)

    Oubre, Cherie M.; Khodadad, Christina L.; Castro, Victoria A.; Ott, C. Mark; Flint, Stephanie; Pollack, Lawrence P.; Roman, Monserrate C.

    2017-01-01

    The RAZOR (trademark) EX, a quantitative Polymerase Chain Reaction (qPCR) instrument, is a portable, ruggedized unit that was designed for the Department of Defense (DoD) with its reagent chemistries traceable to a Small Business Innovation Research (SBIR) contract beginning in 2002. The PCR instrument's primary function post 9/11 was to enable frontline soldiers and first responders to detect biological threat agents and bioterrorism activities in remote locations to include field environments. With its success for DoD, the instrument has also been employed by other governmental agencies including Department of Homeland Security (DHS). The RAZOR (Trademark) EX underwent stringent testing by the vendor, as well as through the DoD, and was certified in 2005. In addition, the RAZOR (trademark) EX passed DHS security sponsored Stakeholder Panel on Agent Detection Assays (SPADA) rigorous evaluation in 2011. The identification and quantitation of microbial pathogens is necessary both on the ground as well as during spaceflight to maintain the health of astronauts and to prevent biofouling of equipment. Currently, culture-based monitoring technology has been adequate for short-term spaceflight missions but may not be robust enough to meet the requirements for long-duration missions. During a NASA-sponsored workshop in 2011, it was determined that the more traditional culture-based method should be replaced or supplemented with more robust technologies. NASA scientists began investigating innovative molecular technologies for future space exploration and as a result, PCR was recommended. Shortly after, NASA sponsored market research in 2012 to identify and review current, commercial, cutting edge PCR technologies for potential applicability to spaceflight operations. Scientists identified and extensively evaluated three candidate technologies with the potential to function in microgravity. After a thorough voice-of-the-customer trade study and extensive functional and

  8. Practical experience with own monitoring of clay sealings on dumps for brown coal-fired power station residues. Erfahrungen mit der Eigenueberwachung an Tonabdichtungen der Deponien fuer Braunkohlenkraftwerksrueckstaende

    Energy Technology Data Exchange (ETDEWEB)

    Winter, K

    1989-07-01

    In order to dispose of power station residues Rheinbraun erects dumps which are encased by a clay sealing. For the Fortuna dump 10 hectares sealing area, with a permeability that is lower than the required limit value of k = 5x10{sup -10} m/s, have so far been constructed. The quality of the sealing is monitored and ensured by graded checking. The practical experience gained so far with own monitoring (selection of material, supervision of construction site and own checking) on the finished clay sealings is discussed in the present paper. The system of testing the sealings has proved very satisfactory. The results of the tests carried out in the course of own monitoring show that processing work in the laboratory can be reduced by systematic selection of material and intensive expert supervision of the construction site. (orig.).

  9. Pilot monitoring program: geologic input for the hillslope component (includes a discussion of Caspar Creek geology and geomorphology)

    Science.gov (United States)

    T. E. Spittler

    1995-01-01

    The California Department of Conservation, Division of Mines and Geology (DMG) is submitting this report and accompanying maps to the California Department of Forestry and Fire Protection (CDF) to fulfill Interagency Agreement number 8CA38400, Pilot Monitoring Program -- Geologic Input for the Hillslope Component. Under this agreement, DMG has assisted CDF in the...

  10. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)

    Czech Academy of Sciences Publication Activity Database

    Berger, T.; Przybyla, B.; Matthia, D.; Reitz, G.; Burmeister, S.; Labrenz, J.; Bilski, P.; Horwacik, T.; Twardak, A.; Hajek, M.; Fugger, M.; Hofstatter, C.; Sihver, L.; Palfalvi, J. K.; Szabó, J.; Stradi, A.; Ambrožová, Iva; Kubančák, Ján; Brabcová, Kateřina; Vanhavere, F.; Cauwels, V.; Van Hoey, O.; Schoonjans, W.; Parisi, A.; Gaza, R.; Semones, E.; Yukihara, E.; Benton, E.; Doull, B. A.; Uchihori, Y.; Kodaira, S.; Kitamura, H.; Böhme, M.

    2016-01-01

    Roč. 6, NOV (2016), č. článku A39. ISSN 2115-7251 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : International Space Station * Columbus * space radiation * DOSIS * DOSIS 3D Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 2.446, year: 2016

  11. Ozone Laminae and Their Entrainment Into a Valley Boundary Layer, as Observed From a Mountaintop Monitoring Station, Ozonesondes, and Aircraft Over California's San Joaquin Valley

    Science.gov (United States)

    Faloona, I. C.; Conley, S. A.; Caputi, D.; Trousdell, J.; Chiao, S.; Eiserloh, A. J., Jr.; Clark, J.; Iraci, L. T.; Yates, E. L.; Marrero, J. E.; Ryoo, J. M.; McNamara, M. E.

    2016-12-01

    The San Joaquin Valley of California is wide ( 75 km) and long ( 400 km), and is situated under strong atmospheric subsidence due, in part, to the proximity of the midlatitude anticyclone of the Pacific High. The capping effect of this subsidence is especially prominent during the warm season when ground level ozone is a serious air quality concern across the region. While relatively clean marine boundary layer air is primarily funneled into the valley below the strong subsidence inversion at significant gaps in the upwind Coast Range mountains, airflow aloft also spills over these barriers and mixes into the valley from above. Because this transmountain flow occurs under the influence of synoptic subsidence it tends to present discrete, laminar sheets of differing air composition above the valley boundary layer. Meanwhile, although the boundary layers tend to remain shallow due to the prevailing subsidence, orographic and anabatic venting of valley boundary layer air around the basin whips up a complex admixture of regional air masses into a "buffer layer" just above the boundary layer (zi) and below the lower free troposphere. We present scalar data of widely varying lifetimes including ozone, methane, NOx, and thermodynamic observations from upwind and within the San Joaquin Valley to better explain this layering and its subsequent erosion into the valley boundary layer via entrainment. Data collected at a mountaintop monitoring station on Chews Ridge in the Coast Range, by coastal ozonesondes, and aircraft are analyzed to document the dynamic layering processes around the complex terrain surrounding the valley. Particular emphasis will be made on observational methods whereby distal ozone can be distinguished from the regional ozone to better understand the influence of exogenous sources on air quality in the valley.

  12. Space Station personal hygiene study

    Science.gov (United States)

    Prejean, Stephen E.; Booher, Cletis R.

    1986-01-01

    A personal hygiene system is currently under development for Space Station application that will provide capabilities equivalent to those found on earth. This paper addresses the study approach for specifying both primary and contingency personal hygiene systems and provisions for specified growth. Topics covered are system definition and subsystem descriptions. Subsystem interfaces are explored to determine which concurrent NASA study efforts must be monitored during future design phases to stay up-to-date on critical Space Station parameters. A design concept for a three (3) compartment personal hygiene facility is included as a baseline for planned test and verification activities.

  13. Technical evaluation report on the monitoring of electric power to the reactor protection system for the Nine Mile Point Nuclear Station, Unit 1 (Docket No. 50-220)

    International Nuclear Information System (INIS)

    Selan, J.C.

    1984-01-01

    This report documents the technical evaluation of the monitoring of electric power to the reactor protection system (RPS) at the Nine Mile Point Nuclear Station, Unit 1. The evaluation is to determine if the proposed design modification will protect the RPS from abnormal voltage and frequency conditions which could be supplied from the power supplies and will meet certain requirements set forth by the Nuclear Regulatory Commission. The proposed design modifications will protect the RPS from sustained abnormal voltage and frequency conditions from the supplying sources

  14. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  15. The use of total susceptibility in the analysis of long term PM10 (PM2.5) collected at Hungarian air quality monitoring stations

    Science.gov (United States)

    Márton, Emö; Domján, Ádám; Lautner, Péter; Szentmarjay, Tibor; Uram, János

    2013-04-01

    Air monitoring stations in Hungary are operated by Environmental, Nature Conservancy and Water Pollution Inspectorates, according to the CEN/TC 264 European Union standards. PM10 samples are collected on a 24-hour basis, for two weeks in February, in May, in August and in November. About 720m3 air is pumped through quartz filters daily. Mass measurements and toxic metal analysis (As, Pb, Cd, Ni) are made on each filter (Whatmann DHA-80 PAH, 150 mm diameter) by the inspectorates. We have carried out low field magnetic susceptibility measurements using a KLY-2 instrument on all PM10 samples collected at 9 stations from 2009 on (a total of more than 2000 filters). One station, located far from direct sources, monitors background pollution. Here PM2.5 was also collected in two-week runs, seven times during the period of 2009-2012 and made available for the non-destructive magnetic susceptibility measurements. Due to the rather weak magnetic signal, the susceptibility of each PM-10 sample was computed from 10, that of each PM2.5 sample from 20 measurements. Corrections were made for the susceptibility of the sample holder, for the unpolluted filter (provided with each of the two-week runs), and for the plastic bag containing the samples. The susceptibilities of the PM10 samples were analyzed from different aspects, like the degree of magnetic pollution at different stations, daily and seasonal variations of the total and mass susceptibilities compared to the mass of the pollutants and in relation to the concentrations of the toxic elements. As expected, the lowest total and mass susceptibilities characterize the background station (pollution arrives mostly from distant sources, Vienna, Bratislava or even the Sudeten), while the highest values were measured for an industrial town with heavy traffic. At the background station the mass of the PM10 and PM2.5, respectively for the same period are quite similar, while the magnetic susceptibilities are usually higher in the

  16. Base Station Performance Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  17. The Remote Monitoring of Earth’s Atmosphere Based on Operative Processing GNSS Data in the UA-EUPOS/ZAKPOS Network of Active Reference Stations

    Directory of Open Access Journals (Sweden)

    Nataliya Kablak

    2016-04-01

    Full Text Available The system of remote monitoring of atmosphere is designed to obtain information about the state of atmosphere. The principle of the remote monitoring of atmosphere is based on registering and processing GLONASS/GPS radio signals. Modern networks of active reference stations allow us to solve both practical problems of geodesy, navigation, and purely scientific problems that are important in all geosciences. The paper investigates a spatiotemporal instability in the atmosphere, based on 845 temporal measurements of tropospheric delay over the territory covered by 20 active reference stations of the UA-EUPOS/ZAKPOS network. The method elaborated by the authors for the determination of tropospheric delay in the UA-EUPOS/ZAKPOS network in real time takes relief of the region into account. The results are very good, since mapping tropospheric delay can be made with an average RMSE of 1.5 mm. The method developed in this research can be used to improve the quality of weather forecasts and the prevention of natural disasters.

  18. In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

    Science.gov (United States)

    Gazda, Daniel B.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2011-01-01

    The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

  19. Ecosystem monitoring of radiocesium redistribution dynamics in a forested catchment in Fukushima after the nuclear power station accident in March 2011

    Science.gov (United States)

    Ohte, N.; Endo, I.; Ohashi, M.; Murakami, M.; Oda, T.; Hotta, N.; Yamanishi, R.; Sugiyama, Y.; Tanoi, K.; Kobayashi, N. I.; Ishii, N.

    2016-12-01

    The accident at the Fukushima Daiichi Nuclear Power Station (F1NPS) in March 2011 emitted 1.2 × 1016 Bq of cesium-137 (137Cs) into the surrounding environment. Radioactive substances, including 137Cs, were deposited onto forested areas in the northeastern region of Japan. To clarify the mechanisms of dispersion and export of 137Cs, within and from a forest ecosystem, we have conducted intensive field observations on hydrological processes and the 137Cs movement and storage in a forested headwater catchment in an area 50 km from F1NNS. Two major pathways of 137Cs transport were focused: 1) through the hydrological processes with dissolved and particulate or colloidal forms, and 2) by dispersion through the food web in the forest-stream ecological continuum. The 137Cs concentrations of stream waters were monitored. Various aquatic and terrestrial organisms were periodically sampled to measure their 137Cs concentrations. The results indicate that the major form of exported 137Cs is via suspended solid in the streamflow. Thus, high flows generated by a storm event accelerated strongly the transportation of 137Cs from the forested catchments. Estimation of 137Cs export from the forested catchments requires precise evaluation of the high water flow during storm events. On the other hand, dissolved form, especially mineral ion form of 137Cs were dominant in througfall and stemflow. Because the biggest pool of 137Cs in the forested ecosystem was the accumulated litters and detritus on the forest floor, 137Cs dispersion through food web was quicker through the detritus food chain than through the grazing food chain. 137Cs concentration of leaves (1.1k Bq/kg), barks (4.4-22.5 kBq/kg) woods (0.1-0.6 kBq/kg) and litters (1.3 kBq/kg) of a dominant deciduous tree (Quercus serrata) suggested that internal cyccling of 137Cs have aready occurred between surface soils including litter layer and plants.

  20. Evaluation of Seismic Response Trends from Long-Term Monitoring of Two Instrumented RC Buildings Including Soil-Structure Interaction

    Directory of Open Access Journals (Sweden)

    Faheem Butt

    2012-01-01

    Full Text Available This paper presents analyses of the seismic responses of two reinforced concrete buildings monitored for a period of more than two years. One of the structures was a three-storey reinforced concrete (RC frame building with a shear core, while the other was a three-storey RC frame building without a core. Both buildings are part of the same large complex but are seismically separated from the rest of it. Statistical analysis of the relationships between maximum free field accelerations and responses at different points on the buildings was conducted and demonstrated strong correlation between those. System identification studies using recorded accelerations were undertaken and revealed that natural frequencies and damping ratios of the building structures vary during different earthquake excitations. This variation was statistically examined and relationships between identified natural frequencies and damping ratios, and the peak response acceleration at the roof level were developed. A general trend of decreasing modal frequencies and increasing damping ratios was observed with increased level of shaking and response. Moreover, the influence of soil structure interaction (SSI on the modal characteristics was evaluated. SSI effects decreased the modal frequencies and increased some of the damping ratios.

  1. On-line vibration and loose parts monitoring of nuclear power stations as a preventive maintenance tool

    International Nuclear Information System (INIS)

    An equipment for on-line monitoring of vibrations and loose parts of nuclear power plants is described. The unit consists of piezoelectric transducers, preamplifiers, a data processor, and peripherals. It secures on-line measurement without interfering with the operation of the power plant. A diagram is given showing the monitor of vibrations and loose parts for pressurized water reactors and the Spectra-Scan equipment for the automatic recording and computer processing of noise signals is described. A survey is given of diagnostic methods for internal vibrations, noise and oscillations and procedures for the analysis of recordings are described. The experiences of Atomica International with the observation of vibrations in nuclear power plants are described and an economic assessment is presented of the efficiency of on-line monitoring of these vibrations. A cost-benefit analysis is made of such equipment which justifies their introduction. (B.S.)

  2. An assessment of invasive plant species monitored by the Northern Research Station Forest Inventory and Analysis Program, 2005 through 2010

    Science.gov (United States)

    Cassandra M. Kurtz

    2013-01-01

    Invasive plant species are a worldwide concern due to the high ecological and economic costs associated with their presence. This document describes the plant characteristics and regional distribution of the 50 invasive plant species monitored from 2005 through 2010 on forested Phase 2 (P2) Forest Inventory and Analysis (FIA) plots in the 24 states of the Northern...

  3. Worker-specific exposure monitor and method for surveillance of workers

    International Nuclear Information System (INIS)

    Lovejoy, M.L.; Peeters, J.P.; Johnson, A.W.

    2000-01-01

    This invention relates to a person-specific monitor that provides sensor information regarding hazards to which the person is exposed and means to geolocate the person at the time of the exposure. The monitor also includes means to communicate with a remote base station. Information from the monitor can be downloaded at the base station for long term storage and analysis. The base station can also include means to recharge the monitor

  4. Monitoring and assessment of health issues at energy plant and gas station Pak steel bin Qasim Karachi

    International Nuclear Information System (INIS)

    Memon, Z.

    2005-01-01

    No doubt Environmental and health safety issues in big cities of Pakistan are developing havoc problems due to mechanized operations by emitting flue gases, effluent and acoustic noise, which it is my topic to discuss in detail. Acoustic noise is one of the major environmental problems in Industrial Plants. The noise study under taken in detail at feed pumps, super heater, exhausters and accumulators of Energy plant (E.P) as the regulators, control room etc. of Gas station (G.S) Pak Steel Bin Qasim Karachi. In light of permissible occupational noise exposure limits, as allowed by the ISO,EEC and other National Standards, some recommendations have been made to provide safety measures for workers against high level noise health hazards like head ache, hearing problem, Irritation, accidents at work, tension, disturbance to work and so many physiological and psychological effects, along with guidelines to overcome the break downs an improve efficiency of the plants. (Orig./A.B.)

  5. Trace elements in aerosols from background air pollution monitoring stations in the Amazon Basin using nuclear-related techniques

    International Nuclear Information System (INIS)

    Artaxo, P.; Martins, J.V.; Yamasoe, M.A.; Gerab, F.; Kocinas, S.

    1994-01-01

    In order to study the natural release of aerosol particles by the Amazon Basin tropical rain forest, the composition and size distribution of biogenic aerosol particles were analyzed. The role of the atmospheric emissions from the Amazon Basin rain forest in the global atmosphere will be investigated. The atmosphere was studied in long-term sampling stations in three different locations. The elemental composition of aerosol particles released during biomass burning was also measured in several different ecosystems, from primary forest to Savannah. One of the main focuses was to identify and quantify important physical and chemical processes in the generation, transformation and deposition of aerosol particles. Also important was to obtain a better understanding of natural aerosol sources concerning identification, their characteristics and strength, to be able to understand the natural chemistry in the atmosphere on a global scale. 36 refs, 3 figs, 3 tabs

  6. Structure of carbon monoxide time variations in the atmospheric thickness over Central Eurasia (Issyk Kul Monitoring Station)

    Science.gov (United States)

    Aref'ev, V. N.; Kashin, F. V.; Orozaliev, M. D.; Sizov, N. I.; Sinyakov, V. P.; Sorokina, L. I.

    2013-03-01

    The results of measurements of the CO content in the atmospheric thickness by the method of solar molecular-absorption spectroscopy are presented. Over 87 months of observations, the annual mean CO content decreased by ˜19% at a mean rate of changes equal to -(0.14 ± 0.02) atm cm per year. Maxima and minima of seasonal variations most often fall on February and September, respectively. The mean overall amplitude of changes in the CO content during the annual cycle is about 50% of the mean value. The Fourier analysis revealed variations in the CO composition with periods from 3 to 84 months. A simple statistical model satisfactorily describes time changes in the CO content in the atmospheric thickness. The results of measurements of the CO content in the atmospheric thickness are compared with the data of CO measurements in samples of surface air at stations of the Global Atmospheric Watch.

  7. The development and testing of a volatile organics concentrator for use in monitoring Space Station water quality

    Science.gov (United States)

    Bodek, Itamar; Ehntholt, Daniel J.; Stolki, Thomas J.; Trabanino, Rudy; Hinsdale, Lloyd; Webb, Johanna; Sauer, Richard L.

    1992-01-01

    The Volatile Organics Concentrator (VOC) system, designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for the analyses of volatile organic compounds in water on Space Station Freedom, is described. Organic volatiles are collected and concentrated in the VOC by means of two primary solid sorbent tubes and desorbed into the GC/MS system. The paper describes the results of testing the VOC breadboard using a GC/MS system. Evaluations performed on 39 organic compounds recovered from water samples were compared with data for these compounds using direct injection/GC/MS and purge and trap/GC/MS procedures. The results demonstrate that the VOC/GC/MS system's detection limits for the 39 compounds analyzed are comparable to those of the EPA Method 524.2, and for many compounds reaching a factor of 5 lower.

  8. A real-time monitoring and assessment method for calculation of total amounts of indoor air pollutants emitted in subway stations.

    Science.gov (United States)

    Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai

    2012-05-01

    Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in

  9. Transparencies used in describing the CTBT verification regime and its four monitoring technologies

    International Nuclear Information System (INIS)

    Basham, P.

    1999-01-01

    This presentation includes description of the CTBT verification regime and its four monitoring technologies, (namely, seismic monitoring, hydro acoustic monitoring, infrasound monitoring and radionuclides monitoring) CTBT global verification system, sequence of steps needed for installing an international monitoring system station which includes: site survey, site preparation and construction, equipment procurement and installation, final tests and certification

  10. Age correction in monitoring audiometry: method to update OSHA age-correction tables to include older workers.

    Science.gov (United States)

    Dobie, Robert A; Wojcik, Nancy C

    2015-07-13

    The US Occupational Safety and Health Administration (OSHA) Noise Standard provides the option for employers to apply age corrections to employee audiograms to consider the contribution of ageing when determining whether a standard threshold shift has occurred. Current OSHA age-correction tables are based on 40-year-old data, with small samples and an upper age limit of 60 years. By comparison, recent data (1999-2006) show that hearing thresholds in the US population have improved. Because hearing thresholds have improved, and because older people are increasingly represented in noisy occupations, the OSHA tables no longer represent the current US workforce. This paper presents 2 options for updating the age-correction tables and extending values to age 75 years using recent population-based hearing survey data from the US National Health and Nutrition Examination Survey (NHANES). Both options provide scientifically derived age-correction values that can be easily adopted by OSHA to expand their regulatory guidance to include older workers. Regression analysis was used to derive new age-correction values using audiometric data from the 1999-2006 US NHANES. Using the NHANES median, better-ear thresholds fit to simple polynomial equations, new age-correction values were generated for both men and women for ages 20-75 years. The new age-correction values are presented as 2 options. The preferred option is to replace the current OSHA tables with the values derived from the NHANES median better-ear thresholds for ages 20-75 years. The alternative option is to retain the current OSHA age-correction values up to age 60 years and use the NHANES-based values for ages 61-75 years. Recent NHANES data offer a simple solution to the need for updated, population-based, age-correction tables for OSHA. The options presented here provide scientifically valid and relevant age-correction values which can be easily adopted by OSHA to expand their regulatory guidance to

  11. Innovation in monitoring: The U.S. Geological Survey Sacramento–San Joaquin River Delta, California, flow-station network

    Science.gov (United States)

    Burau, Jon; Ruhl, Cathy; Work, Paul A.

    2016-01-29

    The U.S. Geological Survey (USGS) installed the first gage to measure the flow of water into California’s Sacramento–San Joaquin River Delta from the Sacramento River in the late 1800s. Today, a network of 35 hydro-acoustic meters measure flow throughout the delta. This region is a critical part of California’s freshwater supply and conveyance system. With the data provided by this flow-station network—sampled every 15 minutes and updated to the web every hour—state and federal water managers make daily decisions about how much freshwater can be pumped for human use, at which locations, and when. Fish and wildlife scientists, working with water managers, also use this information to protect fish species affected by pumping and loss of habitat. The data are also used to help determine the success or failure of efforts to restore ecosystem processes in what has been called the “most managed and highly altered” watershed in the country.

  12. On the problems of monitoring the total alpha acitivity concentration of the air in the vicinity of nuclear power stations

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.

    1983-01-01

    The immission measurement of alpha rays as an environmental monitoring programme is necessary for the production and processing of fuel elements and the WAA. Keeping within the dose limits according to Strl Sch V can only be achieved, if the important radio nuclides are detected with a detection limit, which corresponds to 1130 of the dose limits. For Pu 239/240, this is 3.7 x 10 -6 Bg/m 3 (0.1 f Cu/m 3 ). These detection limits can be achieved by analysis of individual nuclides. (DG) [de

  13. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations.

    Science.gov (United States)

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-10-22

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric (137)Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12-23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric (137)Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models.

  14. La mappa acustica dinamica di Milano da un numero limitato di punti di monitoraggio. Primi risultati - Milan dynamic noise mapping from few monitoring stations. First results

    Directory of Open Access Journals (Sweden)

    Giovanni Zambon

    2016-10-01

    Full Text Available Il questa memoria sono riportati i primi risultati del progetto Dynamap relativi all’area pilota di Milano. Il progetto sviluppa un approccio alla rappresentazione del rumore derivante da traffico stradale che consenta una mappatura acustica dinamica attraverso la scalatura di mappe precalcolate mediante un collegamento diretto con un numero limitato di stazioni di monitoraggio. La possibilità di controllare la mappa acustica di una rete stradale estesa mediante pochi punti di controllo si attua mediante una necessaria aggregazione degli archi stradali in gruppi omogenei. ------ This memory reports the first results of Dynamap project related to the Milan pilot area. The project develops an approach to represent road traffic noise with the outcome of a dynamic noise mapping achieved through the scaling of precalculated maps; scaling is based upon a direct connection to a limited number of noise monitoring stations. The possibility of controlling the acoustic map of an extended road network by means of a few monitoring sites is implemented through a preliminary aggregation of road stretches into homogeneous groups.

  15. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations

    Science.gov (United States)

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-01-01

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric 137Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12–23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric 137Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models. PMID:25335435

  16. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen

  17. Natural Radioactivity Accumulated in the Arctic from Long-range Atmospheric Transport - Observations in Canadian Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jing; Zhang, Weihua [Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa K1A 1C1 (Canada)

    2014-07-01

    In the environment, the main sources of naturally occurring radionuclides come from radionuclides in the uranium decay series. Activity concentrations of uranium decay series radionuclides may vary considerably from place to place depending on the geological characteristics at the location. Their releases to the atmosphere are mainly through radon ({sup 222}Rn), a radioactive noble gas occurring naturally as an indirect decay product of uranium in soils and rocks. Due to the abundance of uranium, radon continuously emanates from continental land masses. With radon as the main source of naturally occurring radioactivity in the environment, one would think that the Arctic should be an area of low background radiation, because a considerable area of the Arctic is covered by glaciers and permafrost, and radon emanation rate has been reported to be negligible from those glacier and permafrost areas. However, available data have shown the opposite. The elevated level of naturally occurring radioactivity in the Arctic is due to natural sources outside of the Arctic, mainly through long-range atmospheric transport of radon and radon progeny. In some cases, natural radioactivity can accumulate to relatively high levels and become a health concern or a limiting factor of country food consumption. By definition, contaminants are undesirable substances which can cause harm to the environment, the biota, and humans. We can call these naturally accumulating radiological burdens to the Arctic 'natural contaminants' to distinguish them from the traditional meaning of contamination, the 'artificial contaminants' which are attributable to industrial or man-made sources. This paper reviews information available in the literature, analyses long-term atmospheric monitoring data in the Canadian high Arctic, sub-Arctic and mid-latitude sites, and provides discussion on research needed to address questions, such as how heavily the Arctic has been impacted by the

  18. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  19. National Seismic Station

    International Nuclear Information System (INIS)

    Stokes, P.A.

    1982-06-01

    The National Seismic Station was developed to meet the needs of regional or worldwide seismic monitoring of underground nuclear explosions to verify compliance with a nuclear test ban treaty. The Station acquires broadband seismic data and transmits it via satellite to a data center. It is capable of unattended operation for periods of at least a year, and will detect any tampering that could result in the transmission of unauthentic seismic data

  20. The Investigation of Hourly,Daily and Seasonal Changes of Duzce Air Quality Monitoring Station 2014 Data

    Directory of Open Access Journals (Sweden)

    Filiz Bolu

    2015-10-01

    Full Text Available Aim: To evaluate data of air quality in the year 2004 in Duzce by days, hours and seasons. Method: In this study, sulfur dioxide, particulate matter levels, wind speed and wind direction values of Duzce city center obtained from the web page of Ministry of Envoriment and Planning between 1 January -31 December 2014 were studied. Data were examined by on the time of hours, days, days of the week, months and seasons. Results: Annual average PM10 was 106,42+/-102 and #956;g/m3 , SO2 concentration was 6,15+/-5,39 and #956;g/m3. Winter PM10 and SO2 measurements were significantly higher than summer season. Wind speed in the summer season had a higher average than the winter season. Highest average PM10 was at November 189,4 +/- 171,8 and #956;g/m3. The lowest PM10 was at June 58,0+/-24,5 and #956;g/m3. The highest average wind speed was at June, the lowest average wind speed is at December. PM10 and SO2 measurements were positively correlated with wind direction, shows a negative correlation with wind speed. The highest PM10 measurements in the summer season were on Thursdays, in the winter season on Wednesdays. The lowest PM10 measurements both in two seasons were on Sundays. Average PM10 was significantly higher on weekdays than weekends. The highest PM10 value of 146,6 +/- 131,3 and #956;g/m3 was measured at 23.00. The lowest PM10 value of 73,8+/-55,9 and #956;g/m3 was measured at 15.00. Conclusion: There is air pollution in Duzce both in the summer and winter. Continuous monitoring of the emissions of existing establishments in the industrial pollution control should be provided. The high PM10 measurements in the evening may be due to traffic during the day and fuel use for heating purposes. Widespread use of natural gas and creating socially conscious individual measures can be effective in reducing air pollution. [TAF Prev Med Bull 2015; 14(5.000: 387-393

  1. Microbial Monitoring from the Frontlines to Space: A Successful Validation of a Department of Defense (DoD) Funded Small Business Innovation Research (SBIR) Technology on Board the International Space Station (ISS)

    Science.gov (United States)

    Oubre, Cherie; Khodadad, Christina; Castro, Victoria; Ott, Mark; Pollack, Lawrence; Roman, Monsi

    2017-01-01

    The RAZOR EX (Registered Trademark) PCR unit was initially developed by the DoD as part of an SBIR project to detect and identify biothreats during field deployment. The system was evaluated by NASA as a commercial technology for future microbial monitoring requirements and has been successfully demonstrated in microgravity on-board the International Space Station.

  2. INTERACT Station Catalogue - 2015

    DEFF Research Database (Denmark)

    INTERACT stations are located in all major environmental envelopes of the Arctic providing an ideal platform for studying climate change and its impact on the environment and local communities. Since alpine environments face similar changes and challenges as the Arctic, the INTERACT network also ...... catalogue includes descriptions of 73 research stations included in the network at the time of printing....

  3. Allaying public concern regarding CO{sub 2} geological sequestration through the development of automated stations for the continuous geochemical monitoring of gases in the near surface environment

    Energy Technology Data Exchange (ETDEWEB)

    Annunziatellis, A.; Beaubien, S.E.; Ciotoli, G.; Lombardi, S. [La Sapienza Univ., Rome (Italy). Dept. of Earth Sciences

    2005-07-01

    Several carbon dioxide (CO{sub 2}) enhanced oil recovery projects conducted in North America have demonstrated that the deep, onshore geological sequestration of anthropogenic CO{sub 2} is technically feasible. However, the technology has yet to be proven to regulators and the general public. It must be demonstrated that carbon sequestration will result in the long-term isolation of the injected CO{sub 2} and that there is no health risk for local residents due to the leakage of CO{sub 2} at surface. It was suggested that in order to alleviate these concerns, low-cost, early warning systems should be installed to monitor gas compositions and concentrations in the soil gas and groundwater. Doing so, would trigger a warning if any increased concentrations of CO{sub 2} or other associated gases were noted in these phases, and allow for early examination of the cause of the anomalous value. In addition, since gas flow is typically along natural faults or abandoned bore holes, installation of monitoring stations around these higher risk sites would help maximize efficiency while minimizing costs. In this study, gas permeable tubing was used to sample soil gas or gases dissolved in groundwater via diffusion. In the case of equilibration with a gas phase the gas concentration within the tubing will eventually match that of the surrounding environment, whereas in the aqueous phase the internal volume of the tube will represent a head space where equilibrium concentrations will be governed by Henry's Constant. CO{sub 2}, hydrogen and hydrogen sulphide from either soil-gas or groundwater were analyzed with low cost infra-red electrochemical detectors. The data was processed with an integrated computer and the results were sent automatically via modem to a central laboratory. The prototype was installed in the San Vittorino Plain in central Italy where it has collected over 5 months of continuous CO{sub 2} data in an area susceptible to sinkhole formation caused by the

  4. Feasibility of estimate sediment yield in the non-sediment monitoring station area - A case study of Alishan River watershed,Taiwan

    Science.gov (United States)

    Chang, ChiaChi; Chan, HsunChuan; Jia, YaFei; Zhang, YaoXin

    2017-04-01

    Due to the steep topography, frail geology and concentrated rainfall in wet season, slope disaster occurred frequently in Taiwan. In addition, heavy rainfall induced landslides in upper watersheds. The sediment yield on the slopeland affects the sediment transport in the river. Sediment deposits on the river bed reduce the river cross section and change the flow direction. Furthermore, it generates risks to residents' lives and property in the downstream. The Taiwanese government has been devoting increasing efforts on the sedimentary management issues and on reduction in disaster occurrence. However, due to the limited information on the environmental conditions in the upper stream, it is difficult to set up the sedimentary monitoring equipment. This study used the upper stream of the Qingshuei River, the Alishan River, as a study area. In August 2009, Typhoon Morakot caused the sedimentation of midstream and downstream river courses in the Alishan River. Because there is no any sediment monitoring stations within the Alishan River watershed, the sediment yield values are hard to determine. The objective of this study is to establish a method to analyze the event-landslide sediment transport in the river on the upper watershed. This study numerically investigated the sediment transport in the Alishan River by using the KINEROS 2 model developed by the United States Department of Agriculture and the CCHE1D model developed by the National Center for Computational Hydroscience and Engineering. The simulated results represent the morphology changes in the Alishan River during the typhoon events. The results consist of a critical strategy reference for the sedimentary management for the Alishan River watershed.

  5. Behaviour of suspended particulate matter (SPM and selected trace metals during the 2002 summer flood in the River Elbe (Germany at Magdeburg monitoring station

    Directory of Open Access Journals (Sweden)

    M. Baborowski

    2004-01-01

    Full Text Available In August 2002, in the worst flooding in more than 100 years, the River Elbe destroyed built-up areas and caused widespread erosion and the relocation of soils and river sediments. To assess the pollutants entering the water, surveys of dissolved constituents and suspended particulate matter (SPM were carried out daily during the flood at a monitoring station near Magdeburg. The sampling point is part of the network of the International Commission for the Protection of the Elbe (ICPE. The results were compared with those of previous flood studies which used the same sampling strategy. Unlike past floods, the 2002 flood was characterised by the transport of relatively fine suspended material with a low mass concentration. Owing to different input sources, the maxima of dry weight and of particle number concentration occurred at different times. Hg, Fe, Mn, Zn, Cu, Ni and Cr showed a maximum concentration concurrent with the dry weight of the SPM, whereas the maximum concentrations of As, Pb, and Cd coincided with the particle number concentration peak. The concentration of particulate matter decreased rapidly, unlike the concentrations of dissolved substances such as DOC and trace metals, as well as the values of UV extinction, all of which remained high for a longer period. Comparing the results of the 2002 flood with the winter floods in 1995, 1999 and 2000, revealed increased values of As and Pb as well as higher concentrations of dissolved compounds. Keywords: river, flood, transport, suspended particulate matter, trace metals, dissolved compounds, Elbe

  6. Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin

    2009-01-01

    Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

  7. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  8. Fire Stations, LAGIC is consulting with local parish GIS departments to create spatially accurate point and polygons data sets including the locations and building footprints of schools, churches, government buildings, law enforcement and emergency response offices, pha, Published in 2011, 1:12000 (1in=1000ft) scale, LSU Louisiana Geographic Information Center (LAGIC).

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Fire Stations dataset current as of 2011. LAGIC is consulting with local parish GIS departments to create spatially accurate point and polygons data sets including...

  9. Amtrak Stations

    Data.gov (United States)

    Department of Homeland Security — Updated database of the Federal Railroad Administration's (FRA) Amtrak Station database. This database is a geographic data set containing Amtrak intercity railroad...

  10. Characterization of a gamma spectrometry monitor LaBr{sub 3} automatic stations for environmental monitoring; Caracterizacion de un monitor de espectrometria gamma de LaBr{sub 3} para las estaciones automaticas de vigilancia ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, A.; Salvador-Castineria, P.; Roig, M.; Fernandez-Varea, J. M.; Padro, A.

    2011-07-01

    The Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya (UPC) is collaborating with the German Radiation Protection (BfS) in order to characterize LaBr{sub 3} detector developed by the BfS for future installation of monitoring networks automatic. This paper presents the results obtained with the monitor installed on the roof of the premises of INTE South Campus located in Barcelona and Monte Carlo simulations that complement its characterization.

  11. Integron, Plasmid and Host Strain Characteristics of Escherichia coli from Humans and Food Included in the Norwegian Antimicrobial Resistance Monitoring Programs.

    Science.gov (United States)

    Sunde, Marianne; Simonsen, Gunnar Skov; Slettemeås, Jannice Schau; Böckerman, Inger; Norström, Madelaine

    2015-01-01

    Antimicrobial resistant Escherichia coli (n=331) isolates from humans with bloodstream infections were investigated for the presence of class 1 and class 2 integrons. The integron cassettes arrays were characterized and the findings were compared with data from similar investigations on resistant E. coli from meat and meat products (n=241) produced during the same time period. All isolates were obtained from the Norwegian monitoring programs for antimicrobial resistance in human pathogens and in the veterinary sector. Methods used included PCR, sequencing, conjugation experiments, plasmid replicon typing and subtyping, pulsed-field-gel-electrophoresis and serotyping. Integrons of class 1 and 2 occurred significantly more frequently among human isolates; 45.4% (95% CI: 39.9-50.9) than among isolates from meat; 18% (95% CI: 13.2 -23.3), (pfood source and from a human clinical sample highlights the possible role of meat as a source of resistance elements for pathogenic bacteria.

  12. Beaver Valley Power Station and Shippingport Atomic Power Station. 1977 annual environmental report: radiological. Volume 2

    International Nuclear Information System (INIS)

    1978-01-01

    The environmental monitoring conducted during 1977 in the vicinity of the Beaver Valley Power Station and the Shippingport Atomic Power Station is described. The environmental monitoring program consists of onsite sampling of water, gaseous, and air effluents, as well as offsite monitoring of water, air, river sediments, and radiation levels in the vicinity of the site. The report discusses releases of small quantities of radioactivity to the Ohio River from the Beaver Valley Power Station and Shippingport Atomic Power Station during 1977

  13. Weigh-in-Motion Stations

    Data.gov (United States)

    Department of Homeland Security — The data included in the GIS Traffic Stations Version database have been assimilated from station description files provided by FHWA for Weigh-in-Motion (WIM), and...

  14. Automatic Traffic Recorder (ATR) Stations

    Data.gov (United States)

    Department of Homeland Security — The data included in the GIS Traffic Stations Version database have been assimilated from station description files provided by FHWA for Weigh-in-Motion (WIM), and...

  15. Robotic weed monitoring

    DEFF Research Database (Denmark)

    Bochtis, Dionysis; Sørensen, Claus Aage Grøn; Jørgensen, R N

    2011-01-01

    Abstract: In this paper, an integrated management system for the planning and activation of thefield monitoring task is presented. The architecture of the system is built around a mobile roboticunit. The internet based architecture of the system includes a station unit that works as a mobileon-fa...... of the weed monitoring operation.Key words: autonomous vehicles, farm management, mission planning, route planning,sampling....

  16. A new watershed assessment framework for Nova Scotia: A high-level, integrated approach for regions without a dense network of monitoring stations

    Science.gov (United States)

    Sterling, Shannon M.; Garroway, Kevin; Guan, Yue; Ambrose, Sarah M.; Horne, Peter; Kennedy, Gavin W.

    2014-11-01

    High-level, integrated watershed assessments are a basic requirement for freshwater planning, as they create regional summaries of multiple environmental stressors for the prioritization of watershed conservation, restoration, monitoring, and mitigation. There is a heightened need for a high-level, integrated watershed assessment in Nova Scotia as it faces pressing watershed issues relating to acidification, soil erosion, acid rock drainage, eutrophication, and water withdrawals related to potential shale gas development. But because of the relative sparseness of the on-the-ground effects-based data, for example on water quality or fish assemblages, previously created approaches for integrated watershed assessment cannot be used. In a government/university collaboration, we developed a new approach that relies solely on easier-to-collect and more available exposure-based variables to perform the first high-level watershed assessment in Nova Scotia. In this assessment, a total of 295 watershed units were studied. We used Geographic Information Systems (GIS) to map and analyze 13 stressor variables that represent risks to aquatic environment (e.g., road/stream crossing density, acid rock drainage risk, surface water withdrawals, human land use, and dam density). We developed a model to link stressors with impacts to aquatic systems to serve as a basis for a watershed threat ranking system. Resource management activities performed by government and other stakeholders were also included in this analysis. Our assessment identifies the most threatened watersheds, enables informed comparisons among watersheds, and indicates where to focus resource management and monitoring efforts. Stakeholder communication tools produced by the NSWAP include a watershed atlas to communicate the assessment results to a broader audience, including policy makers and public stakeholders. This new framework for high-level watershed assessments provides a resource for other regions that also

  17. Waste Transfer Stations

    DEFF Research Database (Denmark)

    Christensen, Thomas Højlund

    2011-01-01

    tion and transport is usually the most costly part of any waste management system; and when waste is transported over a considerable distance or for a long time, transferring the waste from the collection vehicles to more efficient transportation may be economically beneficial. This involves...... a transfer station where the transfer takes place. These stations may also be accessible by private people, offering flexibility to the waste system, including facilities for bulky waste, household hazardous waste and recyclables. Waste transfer may also take place on the collection route from small...... describes the main features of waste transfer stations, including some considerations about the economical aspects on when transfer is advisable....

  18. Rf Station For Ion Beam Staking In Hirfl-csr

    CERN Document Server

    Arbuzov, V S; Bushuev, A A; Dranichnikov, A N; Gorniker, E I; Kendjebulatov, E K; Kondakov, A A; Kondaurov, M; Kruchkov, Ya G; Krutikhin, S A; Kurkin, G Ya; Mironenko, L A; Motygin, S V; Osipov, V N; Petrov, V M; Pilan, Andrey M; Popov, A M; Rashenko, V V; Selivanov, A N; Shteinke, A R; Vajenin, N F

    2004-01-01

    BINP has developed and produced the RF station for Institute of Modern Physics (IMP), Lanzhou, China, for multipurpose accelerator complex with electron cooling. The RF station will be used for accumulation of ion beams in the main ring of the system. It was successfully tested in IMP and installed into the main accelerator ring of the complex. The RF station includes accelerating RF cavity and RF power generator with power supplies. The station works within frequency range 6.0 - 14.0 MHz, maximum voltage across the accelerating gap of the RF cavity - 20 kV. In the RF cavity the 200 VNP ferrite is utilized. A residual gas pressure in vacuum chamber does not exceed 2,5E-11 mbar. Maximum output power of the RF generator 25 kW. The data acquisition and control of the RF station is based on COMPACT - PCI bus and provides all functions of monitoring and control.

  19. National Coral Reef Monitoring Program: benthic images collected from climate stations across the Hawaiian Archipelago from 2016-07-16 to 2016-09-21 (NCEI Accession 0164296)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Hawaiian...

  20. National Coral Reef Monitoring Program: Benthic Percent Cover Derived from Analysis of Benthic Images Collected for Climate Stations across the Hawaiian Archipelago since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  1. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across Wake Island from 2014-03-16 to 2014-03-19 (NCEI Accession 0159139)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Pacific Remote...

  2. National Coral Reef Monitoring Program: Benthic Percent Cover Derived from Analysis of Benthic Images Collected for Climate Stations across American Samoa in 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  3. National Coral Reef Monitoring Program: Benthic Cover Derived from Analysis of Benthic Images Collected for Climate Stations across American Samoa in 2015 (NCEI Accession 0157753)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  4. National Coral Reef Monitoring Program: Benthic Percent Cover Derived from Analysis of Benthic Images Collected for Climate Stations across the Mariana Archipelago in 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  5. National Coral Reef Monitoring Program: Benthic Percent Cover Derived from Analysis of Benthic Images Collected for Climate Stations across the Pacific Remote Island Areas since 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  6. Space Station fluid management logistics

    Science.gov (United States)

    Dominick, Sam M.

    1990-01-01

    Viewgraphs and discussion on space station fluid management logistics are presented. Topics covered include: fluid management logistics - issues for Space Station Freedom evolution; current fluid logistics approach; evolution of Space Station Freedom fluid resupply; launch vehicle evolution; ELV logistics system approach; logistics carrier configuration; expendable fluid/propellant carrier description; fluid carrier design concept; logistics carrier orbital operations; carrier operations at space station; summary/status of orbital fluid transfer techniques; Soviet progress tanker system; and Soviet propellant resupply system observations.

  7. Police Stations, City of Wichita Police Department substation locations. Cover is derived from Emergency Facilities (scEfac) cover. Used for Public Safety map rolls. Primary attributes include station number, address, mailing city, type, and name., Published in 2008, 1:1200 (1in=100ft) scale, Sedgwick County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Police Stations dataset current as of 2008. City of Wichita Police Department substation locations. Cover is derived from Emergency Facilities (scEfac) cover. Used...

  8. Airborne monitoring system

    International Nuclear Information System (INIS)

    Kadmon, Y.; Gabovitch, A.; Tirosh, D.; Ellenbogen, M.; Mazor, T.; Barak, D.

    1997-01-01

    A complete system for tracking, mapping, and performing a composition analysis of a radioactive plume and contaminated area was developed at the NRCN. The system includes two major units : An airborne unit for monitoring and a ground station for analyzing. The airborne unit is mounted on a helicopter and includes file following. Four radiation sensor, two 2'' x 2'' Nal (Tl) sensors horizontally separated by lead shield for mapping and spectroscopy, and two Geiger Mueller (GM) tubes as part of the safety system. A multichannel analyzer card is used for spectroscopy. A navigation system, based on GPS and a barometric altitude meter, is used to locate the plume or ground data. The telemetry system, consisting of a transceiver and a modem, transfers all the data in real time to the ground station. An industrial PC (Field Works) runs a dedicated C++ Windows application to manage the acquired data. An independent microprocessor based backup system includes a recorder, display, and key pad. The ground station is based on an industrial PC, a telemetry system, a color printer and a modem to communicate with automatic meteorology stations in the relevant area. A special software controls the ground station. Measurement results are analyzed in the ground station to estimate plume parameters including motion, location, size, velocity, and perform risk assessment. (authors)

  9. Development of method for detecting signs deterioration in insulator of high-voltage motors. 2. Test Results of a new on-line partial discharge monitor for high-voltage motors in nuclear power stations

    International Nuclear Information System (INIS)

    Tochio, Atsushi; Kaneda, Yoshiharu; Urakawa, Nobuo

    2000-01-01

    For the purpose of early detection of deterioration of insulators in high-voltage motors which are widely utilized in nuclear power stations, a new on-line partial discharge (PD) monitor was developed and was tested for sixteen motors which were practically running in nuclear power stations. From the test results, it is seen that (1) good signal to noise ratio is obtained by adopting a two frequency correlation method, (2) a resistance temperature detector (RTD) in a motor has sufficient sensitivity to detect PD, (3) when RTD is not installed or is unable to use for this purpose, a radio frequency current transformer (RFCT) can be utilized, although its sensitivity is about 1/10 of that of the RTD monitor. Finally we found a good correlation between the results of this on-line method and the conventional off-line method in which the insulator resistance of a concerned motor was measured during its shut-down, and thereby we demonstrated that this method could be applicable to the on-line test of high-voltage motors in nuclear power stations. (author)

  10. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    the probability of conflicts and the minimum headway times into account. The last method analyzes how optimal platform tracks are used by examining the arrival and departure pattern of the trains. The developed methods can either be used separately to analyze specific characteristics of the capacity of a station......Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore...... for platform tracks and the probability that arriving trains will not get a platform track immediately at arrival. The third method is a scalable method that analyzes the conflicts in the switch zone(s). In its simplest stage, the method just analyzes the track layout while the more advanced stages also take...

  11. The nuclear power station

    International Nuclear Information System (INIS)

    Plettner, B.

    1987-04-01

    The processes taking place in a nuclear power plant and the dangers arising from a nuclear power station are described. The means and methods of controlling, monitoring, and protecting the plant and things that can go wrong are presented. There is also a short discourse on the research carried out in the USA and Germany, aimed at assessing the risks of utilising nuclear energy by means of the incident tree analysis and probability calculations. (DG) [de

  12. Space Station Engineering Design Issues

    Science.gov (United States)

    Mcruer, Duane T.; Boehm, Barry W.; Debra, Daniel B.; Green, C. Cordell; Henry, Richard C.; Maycock, Paul D.; Mcelroy, John H.; Pierce, Chester M.; Stafford, Thomas P.; Young, Laurence R.

    1989-01-01

    Space Station Freedom topics addressed include: general design issues; issues related to utilization and operations; issues related to systems requirements and design; and management issues relevant to design.

  13. Monitoring Regional Forest Disturbances across the US with Near Real Time MODIS NDVI Products included in the ForWarn Forest Threat Early Warning System

    Science.gov (United States)

    Spruce, Joseph; Hargrove, William W.; Gasser, Gerald; Norman, Steve

    2013-01-01

    U.S. forests occupy approx.1/3 of total land area (approx. 304 million ha). Since 2000, a growing number of regionally evident forest disturbances have occurred due to abiotic and biotic agents. Regional forest disturbances can threaten human life and property, bio-diversity and water supplies. Timely regional forest disturbance monitoring products are needed to aid forest health management work. Near Real Time (NRT) twice daily MODIS NDVI data provide a means to monitor U.S. regional forest disturbances every 8 days. Since 2010, these NRT forest change products have been produced and posted on the US Forest Service ForWarn Early Warning System for Forest Threats.

  14. Systems and method for lagrangian monitoring of flooding conditions

    KAUST Repository

    Claudel, Christian G.; Shamim, Atif; Farooqui, Muhammad Fahad

    2015-01-01

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do

  15. Programmatic environmental impact statement related to decontamination and disposal of radioactive wastes resulting from March 28, 1979 accident, Three Mile Island Nuclear Station, Unit 2 (Docket No. 50-320): Draft supplement dealing with post-defueling monitored storage and subsequent cleanup

    International Nuclear Information System (INIS)

    1988-04-01

    In accordance with the National Environmental Policy Act, the Commission's implementing regulations, and its April 27, 1981,Statement of Policy, the Programmatic environmental impact statement related to decontamination and disposal of radioactive wastes resulting from March 28, 1979 accident Three Mile Island Nuclear Station, Unit 2, NUREG-0683 (PEIS) is being supplemented. This draft supplement updates the enviromental evaluation of cleanup alternatives published in the PEIS, utilizing more complete and current information. Also, the draft supplement includes a specific environmental evaluation of the licensee's recently submitted proposal for post-defueling monitored storage. The NRC staff has concluded that the licensee's proposal to place the facility in a monitored storage configuration will not significantly affect the quality of the human environment. Further, any impacts from the long-term storage of the facility are outweighed by its benefits. 63 refs., 23 figs., 65 tabs

  16. Rapid analysis of U isotopes in vegetables using ICP-MS. Application to the emergency U monitoring after the nuclear accident at TEPCO's Fukushima Dai-ichi power station

    International Nuclear Information System (INIS)

    Jian Zheng; Keiko Tagami; Shigeo Uchida

    2012-01-01

    After the nuclear accident at TEPCO's Fukushima Dai-ichi power station in March, hydrogen explosions and reactor building explosion resulted in releases of radionuclides in the environment. Severe radioactive cesium and iodine contaminations have been observed in fallout deposition samples and soils in the East Japan. Radioactive cesium, iodine, uranium, and transuranic radionuclides were set as the monitoring targets in food safety tests. However, so far, only radioactive cesium and iodine were daily measured and reported by the Ministry of Health, Labour, and Welfare. The tedious and time consuming conventional alpha spectrometric method hampered the emergency monitoring U contamination in foods. In this work, we propose a simple and rapid analytical method for 238 U and 235 U/ 238 U isotope ratio analysis in fresh vegetables. This method was applied to the emergency monitoring of radioactive contamination after the nuclear accident at TEPCO's Fukushima Dai-ichi power station. The results showed no U contamination in fresh vegetables collected in Chiba and Ibaraki prefectures in April and May, 2011. (author)

  17. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  18. Real-time monitoring of radiofrequency ablation of liver tumors using thermal-dose calculation by MR temperature imaging: initial results in nine patients, including follow-up

    International Nuclear Information System (INIS)

    Lepetit-Coiffe, Matthieu; Quesson, Bruno; Moonen, Chrit T.W.; Laumonier, Herve; Trillaud, Herve; Seror, Olivier; Sesay, Musa-Bahazid; Grenier, Nicolas

    2010-01-01

    To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas and one colorectal metastasis), were treated by 12-min RF ablation using a 1.5-T closed magnet for real-time temperature monitoring. The clinical monopolar RF device was filtered at 64 MHz to avoid electromagnetic interference. Real-time computation of thermal-dose (TD) maps, based on Sapareto and Dewey's equation, was studied to determine its ability to provide a clear end-point of the RF procedure. Absence of local recurrence on follow-up MR images obtained 45 days after the RF ablation was used to assess the apoptotic and necrotic prediction obtained by real-time TD maps. Seven out of nine tumours were completely ablated according to the real-time TD maps. Compared with 45-day follow-up MR images, TD maps accurately predicted two primary treatment failures, but were not relevant in the later progression of one case of secondary local tumour. The real-time TD concept is a feasible and promising monitoring method for the RF ablation of liver tumours. (orig.)

  19. Real-time monitoring of radiofrequency ablation of liver tumors using thermal-dose calculation by MR temperature imaging: initial results in nine patients, including follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Lepetit-Coiffe, Matthieu; Quesson, Bruno; Moonen, Chrit T.W. [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Laumonier, Herve; Trillaud, Herve [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service de Radiologie, Hopital Saint-Andre, CHU Bordeaux, Bordeaux (France); Seror, Olivier [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service de Radiologie, Hopital Jean Verdier, Bondy (France); Sesay, Musa-Bahazid [Service d' Anesthesie Reanimation III, Hopital Pellegrin, CHU Bordeaux, Bordeaux (France); Grenier, Nicolas [Universite Victor Segalen Bordeaux 2, Laboratoire Imagerie Moleculaire et Fonctionnelle: de la physiologie a la therapie CNRS UMR 5231, Bordeaux Cedex (France); Service d' Imagerie Diagnostique et Therapeutique de l' Adulte, Hopital Pellegrin, CHU Bordeaux, Bordeaux (France)

    2010-01-15

    To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas and one colorectal metastasis), were treated by 12-min RF ablation using a 1.5-T closed magnet for real-time temperature monitoring. The clinical monopolar RF device was filtered at 64 MHz to avoid electromagnetic interference. Real-time computation of thermal-dose (TD) maps, based on Sapareto and Dewey's equation, was studied to determine its ability to provide a clear end-point of the RF procedure. Absence of local recurrence on follow-up MR images obtained 45 days after the RF ablation was used to assess the apoptotic and necrotic prediction obtained by real-time TD maps. Seven out of nine tumours were completely ablated according to the real-time TD maps. Compared with 45-day follow-up MR images, TD maps accurately predicted two primary treatment failures, but were not relevant in the later progression of one case of secondary local tumour. The real-time TD concept is a feasible and promising monitoring method for the RF ablation of liver tumours. (orig.)

  20. Power stations

    International Nuclear Information System (INIS)

    Cawte, H.; Philpott, E.F.

    1980-01-01

    The object is to provide a method of operating a dual purpose power station so that the steam supply system is operated at a high load factor. The available steam not required for electricity generation is used to provide process heat and the new feature is that the process plant capacity is determined to make the most economic use of the steam supply system, and not to match the passout capacity of the turbine of the turbogenerator. The product of the process plant should, therefore, be capable of being stored. A dual-purpose power station with a nuclear-powered steam source, turbogenerating means connected to the steam source and steam-powered process plant susceptible to wide variation in its rate of operation is described. (U.K.)

  1. The Princess Elisabeth Station

    Science.gov (United States)

    Berte, Johan

    2012-01-01

    Aware of the increasing impact of human activities on the Earth system, Belgian Science Policy Office (Belspo) launched in 1997 a research programme in support of a sustainable development policy. This umbrella programme included the Belgian Scientific Programme on Antarctic Research. The International Polar Foundation, an organization led by the civil engineer and explorer Alain Hubert, was commissioned by the Belgian Federal government in 2004 to design, construct and operate a new Belgian Antarctic Research Station as an element under this umbrella programme. The station was to be designed as a central location for investigating the characteristic sequence of Antarctic geographical regions (polynia, coast, ice shelf, ice sheet, marginal mountain area and dry valleys, inland plateau) within a radius of 200 kilometers (approx.124 miles) of a selected site. The station was also to be designed as "state of the art" with respect to sustainable development, energy consumption, and waste disposal, with a minimum lifetime of 25 years. The goal of the project was to build a station and enable science. So first we needed some basic requirements, which I have listed here; plus we had to finance the station ourselves. Our most important requirement was that we decided to make it a zero emissions station. This was both a philosophical choice as we thought it more consistent with Antarctic Treaty obligations and it was also a logistical advantage. If you are using renewable energy sources, you do not have to bring in all the fuel.

  2. Preliminary comparative assessment of PM10 hourly measurement results from new monitoring stations type using stochastic and exploratory methodology and models

    Science.gov (United States)

    Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł

    2018-01-01

    The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.

  3. Solar Weather Ice Monitoring Station (SWIMS). A low cost, extreme/harsh environment, solar powered, autonomous sensor data gathering and transmission system

    Science.gov (United States)

    Chetty, S.; Field, L. A.

    2013-12-01

    The Arctic ocean's continuing decrease of summer-time ice is related to rapidly diminishing multi-year ice due to the effects of climate change. Ice911 Research aims to develop environmentally respectful materials that when deployed will increase the albedo, enhancing the formation and/preservation of multi-year ice. Small scale deployments using various materials have been done in Canada, California's Sierra Nevada Mountains and a pond in Minnesota to test the albedo performance and environmental characteristics of these materials. SWIMS is a sophisticated autonomous sensor system being developed to measure the albedo, weather, water temperature and other environmental parameters. The system (SWIMS) employs low cost, high accuracy/precision sensors, high resolution cameras, and an extreme environment command and data handling computer system using satellite and terrestrial wireless communication. The entire system is solar powered with redundant battery backup on a floating buoy platform engineered for low temperature (-40C) and high wind conditions. The system also incorporates tilt sensors, sonar based ice thickness sensors and a weather station. To keep the costs low, each SWIMS unit measures incoming and reflected radiation from the four quadrants around the buoy. This allows data from four sets of sensors, cameras, weather station, water temperature probe to be collected and transmitted by a single on-board solar powered computer. This presentation covers the technical, logistical and cost challenges in designing, developing and deploying these stations in remote, extreme environments. Image captured by camera #3 of setting sun on the SWIMS station One of the images captured by SWIMS Camera #4

  4. Ecosystem monitoring on dispersion and export dynamics of ¹³⁷Cs deposited on the forested area in Fukushima after the nuclear power stations accident in March 2011

    Energy Technology Data Exchange (ETDEWEB)

    Ohte, Nobuhito; Endo, Izuki; Iseda, Kohei; Tanoi, Keitaro [University of Tokyo, Bunkyo-ku, Tokyo, 113-8657 (Japan); Murakami, Masashi [Chiba University, Inage-ku, Chiba, 263-8522 (Japan); Ishii, Nobuyoshi [National Institute of Radiological Sciences, Inage-ku, Chiba, 263-8555 (Japan)

    2014-07-01

    The accident of the Fukushima Daiichi Nuclear Power Stations in March 2011 emitted 1.5x10¹⁷ Bq of ¹³¹I, 1.2x10¹⁶ Bq of ¹³⁷Cs into the surrounding environment. Those radioactive substances including ¹³⁷Cs deposited onto the forest areas of the northeastern region of the Honshu Island, Japan. Forests of these regions are especially important for the people not only for their forest production industry, but also for the source areas of drinking water. The first phase of the governmental survey and investigations showed that major portion of deposited ¹³⁷Cs is trapped on the canopies and litter layers of soil surface. As ¹³⁷Cs is easily adsorbed onto clay minerals in soil, major portion of those can be transported by eroded soils and particulate organic matters through the hydrological pathways. Dissolved ¹³⁷Cs which is relatively free from soil adsorption can be taken up by microbes, algae and plants in soil and aquatic systems. Then, those ¹³⁷Cs are eventually introduced into soil insects, worms, aquatic insects, fishes and birds through the food web. To clarify the mechanisms of dispersion and export of ¹³⁷Cs within and from a forested ecosystem, we started intensive field observations and samplings in a small catchment including forests and farmlands in the area ~50 km distant from the Nuclear Power Station. The study is conducted at the Kami-Oguni River catchment in the northern part of Fukushima Prefecture. Major land uses of the catchment are forests and paddy fields. Expected two major pathways of ¹³⁷Cs diffusion and export are investigated; 1) transportation by water movement with dissolved and particulate or colloidal forms through the hydrological processes, 2) dispersion through the food web including both detritus food chains based upon plant litters and grazing food chains based upon living plant leaves in the forest-stream ecological continuum. The ¹³⁷Cs concentrations of stream waters at several sampling

  5. Integrated architecture of monitoring, supervisory and automatic control for optimization of the operations in the natural gas turbo compressor station at Guamare - state of Rio Grande do Norte - Brazil

    International Nuclear Information System (INIS)

    Nascimento Filho, Epitacio

    2000-01-01

    This paper presents the conception and the benefits of the integrated supervisory control architecture for performance, aero thermodynamic and mechanical monitoring of the Ubarana Phase V Turbo compressor Station in Guamare-Rn. The compression station has four gas turbines, each one developing 6.640 kW ( 9.600 rpm - ISO power), driving four centrifugal compressors, each one with unitary capacity of 850.000 m 3 /d, arranged in parallel. The integrated architecture allows the continuous tele monitoring of a large range of mechanical and process parameters. Other resources are real time identification of deterioration signs or performance decaying of each machine in service, serving as a precious tool for the operation and maintenance decisions like wash application intervals and partial or general equipment revision. Just for the sake of operational cost impacts: a small increase of 1% in overall thermal efficiency represents a reduction of US$ 60,000 in annual operational cost, since the annual fuel consume nears US$ 6 million (considering 20 MW with 8,000 h). (author)

  6. A comparative study of night-time enhancement of TEC at a low latitude station on storm and quiet nights including the local time, seasonal and solar activity dependence

    Directory of Open Access Journals (Sweden)

    K. Unnikrishnan

    Full Text Available The main characteristics of night-time enhancements in TEC during magnetic storms are compared with those during quiet nights for different seasons and solar activity conditions at Palehua, a low latitude station during the period 1980–1989. We find that the mean amplitude has both a seasonal and solar activity dependence: in winter, the values are higher for weak storms as compared to those during quiet nights and increase with an increase in solar activity. In summer, the mean amplitude values during weak storms and quiet nights are almost equal. But during equinox, the mean amplitude values for quiet nights are greater than those during weak storms. The mean half-amplitude duration is higher during weak storms as compared to that during quiet nights in summer. However, during winter and equinox, the durations are almost equal for both quiet and weak storm nights. For the mean half-amplitude duration, the quiet night values for all the seasons and equinoctial weak storm values increase with an increase in solar activity. The occurrence frequency (in percent of TEC enhancement during weak storms is greater than during quiet nights for all seasons. The mean amplitude, the mean half-amplitude duration and the occurrence frequency (in percent of TEC enhancement values are higher during major storms as compared to those during quiet nights. The above parameters have their highest values during pre-midnight hours. From the data analysed, this behaviour is true in the case of major storms also.

    Key words. Ionosphere (ionospheric disturbances; plasma convection Magnetospheric physics (storms and substorms

  7. Radiation monitoring network in Poland

    International Nuclear Information System (INIS)

    Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Smagala, G.; Swietochowska, J.

    2001-01-01

    In Poland the radioactive contamination of the environment and food has been controlled since the early sixties by the Service for Measurements of Radioactive Contamination (SPSP). The service comprises a network of measuring stations and the Centre of Radioactive Contamination Measurements (COPSP). Actually, there are 100 measurement stations. The main task of such station is systematic measurement of radioactivity level in samples of environment components and food. Nine stations of SPSP acting within meteorological stations, ten stations of low level air radioactivity measurements (Aerosols Sampling Stations-500) and eleven permanent monitoring stations (PMS) form the radiation monitoring warning system in Poland. (author)

  8. Hydrogen Fuelling Stations

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus Damgaard

    . A system consisting of one high pressure storage tank is used to investigate the thermodynamics of fuelling a hydrogen vehicle. The results show that the decisive parameter for how the fuelling proceeds is the pressure loss in the vehicle. The single tank fuelling system is compared to a cascade fuelling......This thesis concerns hydrogen fuelling stations from an overall system perspective. The study investigates thermodynamics and energy consumption of hydrogen fuelling stations for fuelling vehicles for personal transportation. For the study a library concerning the components in a hydrogen fuelling...... station has been developed in Dymola. The models include the fuelling protocol (J2601) for hydrogen vehicles made by Society of Automotive Engineers (SAE) and the thermodynamic property library CoolProp is used for retrieving state point. The components in the hydrogen fuelling library are building up...

  9. Support and Maintenance of the International Monitoring System network

    Science.gov (United States)

    Pereira, Jose; Bazarragchaa, Sergelen; Kilgour, Owen; Pretorius, Jacques; Werzi, Robert; Beziat, Guillaume; Hamani, Wacel; Mohammad, Walid; Brely, Natalie

    2014-05-01

    The Monitoring Facilities Support Section of the Provisional Technical Secretariat (PTS) has as its main task to ensure optimal support and maintenance of an array of 321 monitoring stations and 16 radionuclide laboratories distributed worldwide. Raw seismic, infrasonic, hydroacoustic and radionuclide data from these facilities constitutes the basic product delivered by the International Monitoring System (IMS). In the process of maintaining such a wide array of stations of different technologies, the Support Section contributes to ensuring station mission capability. Mission capable data availability according to the IMS requirements should be at least 98% annually (no more than 7 days down time per year per waveform stations - 14 continuous for radionuclide stations) for continuous data sending stations. In this presentation, we will present our case regarding our intervention at stations to address equipment supportability and maintainability, as these are particularly large activities requiring the removal of a substantial part of the station equipment and installation of new equipment. The objective is always to plan these activities while minimizing downtime and continuing to meet all IMS requirements, including those of data availability mentioned above. We postulate that these objectives are better achieved by planning and making use of preventive maintenance, as opposed to "run-to-failure" with associated corrective maintenance. We use two recently upgraded Infrasound Stations (IS39 Palau and IS52 BIOT) as a case study and establish a comparison between these results and several other stations where corrective maintenance was performed, to demonstrate our hypothesis.

  10. Ambulatory blood pressure monitoring and development of cardiovascular events in high-risk patients included in the Spanish ABPM registry: the CARDIORISC Event study.

    Science.gov (United States)

    de la Sierra, Alejandro; Banegas, José R; Segura, Julián; Gorostidi, Manuel; Ruilope, Luis M

    2012-04-01

    Ambulatory blood pressure monitoring (ABPM) is superior to conventional BP measurement in predicting outcome, with baseline 24-h, daytime and night-time absolute values, as well as relative nocturnal decline, as powerful determinants of prognosis. We aimed to evaluate ABPM estimates on the appearance of cardiovascular events and mortality in a cohort of high-risk treated hypertensive patients. A total of 2115 treated hypertensive patients with high or very high added risk were evaluated by means of office and 24-h ABPM. Cardiovascular events and mortality were assessed after a median follow-up of 4 years. Two hundred and sixty-eight patients (12.7%) experienced a primary event (nonfatal coronary or cerebrovascular event, heart failure hospitalization or cardiovascular death) and 114 died (45 from cardiovascular causes). In a multiple Cox regression model, and after adjusting for baseline cardiovascular risk and office BP, night-time SBP predicted cardiovascular events [hazard ratio for each SD increase: 1.45; 95% confidence interval (CI) 1.29-1.59]. Values above 130 mmHg increased the risk by 52% in comparison to values less than 115 mmHg. In addition to clinical determinants of cardiovascular risk and conventional BP, ABPM performed during treatment adds prognostic significance on the development of cardiovascular events in high-risk hypertensive patients. Among different ABPM-derived values, night-time SBP is the most potent predictor of outcome.

  11. Monitoring of the spatial and temporal dynamics of BER/SSBR pathway proteins, including MYH, UNG2, MPG, NTH1 and NEIL1-3, during DNA replication.

    Science.gov (United States)

    Bj Rås, Karine Ø; Sousa, Mirta M L; Sharma, Animesh; Fonseca, Davi M; S Gaard, Caroline K; Bj Rås, Magnar; Otterlei, Marit

    2017-08-21

    Base lesions in DNA can stall the replication machinery or induce mutations if bypassed. Consequently, lesions must be repaired before replication or in a post-replicative process to maintain genomic stability. Base excision repair (BER) is the main pathway for repair of base lesions and is known to be associated with DNA replication, but how BER is organized during replication is unclear. Here we coupled the iPOND (isolation of proteins on nascent DNA) technique with targeted mass-spectrometry analysis, which enabled us to detect all proteins required for BER on nascent DNA and to monitor their spatiotemporal orchestration at replication forks. We demonstrate that XRCC1 and other BER/single-strand break repair (SSBR) proteins are enriched in replisomes in unstressed cells, supporting a cellular capacity of post-replicative BER/SSBR. Importantly, we identify for the first time the DNA glycosylases MYH, UNG2, MPG, NTH1, NEIL1, 2 and 3 on nascent DNA. Our findings suggest that a broad spectrum of DNA base lesions are recognized and repaired by BER in a post-replicative process. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. [The significance of enviromental and biological monitoring in workers employed in service stations after the elimitation of tetraethyl lead from gasoline].

    Science.gov (United States)

    Ghittori, S; Ferrari, M; Maestri, L; Negri, S; Zadra, P; Gremita, C; Imbriani, M

    2005-01-01

    The chemical risk in service stations may be due to toxic compounds present in fuel (particularly benzene and additives) and to the emission of exhausts and fine particulate from vehicles. Owing to the elimination of lead (Pb) from fuel and to the necessity of lowering CO emission, several oxygenated additives have been added to fuel, in particular methyl-tert-butyl-ether (MTBE), whose toxic properties are at present under investigation. The introduction of reformulated gasoline (RFG) and the use of catalytic converters (with possible release of platinum (Pt) in the environment) may have modified the risks for workers employed in service stations. The paper shows data collected from 26 subjects (divided into three specific tasks, namely: fuel dispenser, "self-service" attendant and controller, and cashier) to estimate the actual chemical risk and to compare it with the previous data taken from literature. For this purpose, besides performing the usual medical surveillance, we measured the environmental concentrations of benzene, MTBE and formaldehyde, the urinary levels of benzene metabolites S-phenylmercapturic acid (S-PMA) and t,t-muconic acid (MA) and of unmodified MTBE, and the blood concentrations of Pb and Pt for each subject. Mean values of these compounds were, respectively: 38.81 microg/m3; 174.04 microg/m3; 10.38 microg/m3; 2.36 microg/g creatinine; 96.57 microg/g creatinine; 1.41 microg/L; 7.00 microg/100 mL; 0.0738 ng/ml. The above values were much lower than the corresponding limit values reported by ACGIH and DFG. In particular, after the introduction of vapour recycle systems and the widespread use of "self-service" systems, airborne benzene concentration dropped from 300/400 microg/m3 to lower than 100 microg/m3, without noticeable increasing of exposure to formaldehyde. The disappearing of Pb from gasoline leads to a progressive lowering of its blood levels, while the possible risks due to the very low amounts of Pt released from catalytic

  13. QUALITY ASSURANCE PERFORMANCE AUDIT REPORT FOR THE SECRETARIA DEL MEDIO AMBIENTE CIUDAD DE MEXICO, DF, MEXICO RED AUTOMATICA DE MONITOREO ATMOSFERICO (RAMA) AIR QUALITY MONITORING STATIONS

    Science.gov (United States)

    The United States Environmental Protection Agency (U.S. EPA) conducted this evaluation of the air monitoring network, known as RAM (Red Automatica de Monitoreo Atmosferico) at the request of the Mexico City Secretariat of the Environment on October 16-27, 2000. This evaluation...

  14. Computer based training simulator for Hunterston Nuclear Power Station

    International Nuclear Information System (INIS)

    Bowden, R.S.M.; Hacking, D.

    1978-01-01

    For reasons which are stated, the Hunterston-B nuclear power station automatic control system includes a manual over-ride facility. It is therefore essential for the station engineers to be trained to recognise and control all feasible modes of plant and logic malfunction. A training simulator has been built which consists of a replica of the shutdown monitoring panel in the Central Control Room and is controlled by a mini-computer. This paper highlights the computer aspects of the simulator and relevant derived experience, under the following headings: engineering background; shutdown sequence equipment; simulator equipment; features; software; testing; maintenance. (U.K.)

  15. MifM monitors total YidC activities of Bacillus subtilis, including that of YidC2, the target of regulation.

    Science.gov (United States)

    Chiba, Shinobu; Ito, Koreaki

    2015-01-01

    The YidC/Oxa1/Alb3 family proteins are involved in membrane protein biogenesis in bacteria, mitochondria, and chloroplasts. Recent studies show that YidC uses a channel-independent mechanism to insert a class of membrane proteins into the membrane. Bacillus subtilis has two YidC homologs, SpoIIIJ (YidC1) and YidC2 (YqjG); the former is expressed constitutively, while the latter is induced when the SpoIIIJ activity is compromised. MifM is a substrate of SpoIIIJ, and its failure in membrane insertion is accompanied by stable ribosome stalling on the mifM-yidC2 mRNA, which ultimately facilitates yidC2 translation. While mutational inactivation of SpoIIIJ has been known to induce yidC2 expression, here, we show that the level of this induction is lower than that observed when the membrane insertion signal of MifM is defective. Moreover, this partial induction of YidC2 translation is lowered further when YidC2 is overexpressed in trans. These results suggest that YidC2 is able to insert MifM into the membrane and to release its translation arrest. Thus, under SpoIIIJ-deficient conditions, YidC2 expression is subject to MifM-mediated autogenous feedback repression. Our results show that YidC2 uses a mechanism that is virtually identical to that used by SpoIIIJ; Arg75 of YidC2 in its intramembrane yet hydrophilic cavity is functionally indispensable and requires negatively charged residues of MifM as an insertion substrate. From these results, we conclude that MifM monitors the total activities of the SpoIIIJ and the YidC2 pathways to control the synthesis of YidC2 and to maintain the cellular capability of the YidC mode of membrane protein biogenesis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. Analysis and detection of functional outliers in water quality parameters from different automated monitoring stations in the Nalón river basin (Northern Spain).

    Science.gov (United States)

    Piñeiro Di Blasi, J I; Martínez Torres, J; García Nieto, P J; Alonso Fernández, J R; Díaz Muñiz, C; Taboada, J

    2015-01-01

    The purposes and intent of the authorities in establishing water quality standards are to provide enhancement of water quality and prevention of pollution to protect the public health or welfare in accordance with the public interest for drinking water supplies, conservation of fish, wildlife and other beneficial aquatic life, and agricultural, industrial, recreational, and other reasonable and necessary uses as well as to maintain and improve the biological integrity of the waters. In this way, water quality controls involve a large number of variables and observations, often subject to some outliers. An outlier is an observation that is numerically distant from the rest of the data or that appears to deviate markedly from other members of the sample in which it occurs. An interesting analysis is to find those observations that produce measurements that are different from the pattern established in the sample. Therefore, identification of atypical observations is an important concern in water quality monitoring and a difficult task because of the multivariate nature of water quality data. Our study provides a new method for detecting outliers in water quality monitoring parameters, using turbidity, conductivity and ammonium ion as indicator variables. Until now, methods were based on considering the different parameters as a vector whose components were their concentration values. This innovative approach lies in considering water quality monitoring over time as continuous curves instead of discrete points, that is to say, the dataset of the problem are considered as a time-dependent function and not as a set of discrete values in different time instants. This new methodology, which is based on the concept of functional depth, was applied to the detection of outliers in water quality monitoring samples in the Nalón river basin with success. Results of this study were discussed here in terms of origin, causes, etc. Finally, the conclusions as well as advantages of

  17. RadNet Air Quality (Fixed Station) Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet is a national network of monitoring stations that regularly collect air for analysis of radioactivity. The RadNet network, which has stations in each State,...

  18. Next Generation Hydrogen Station Composite Data Products: Retail Stations, Data through Quarter 4 of 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Sam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-31

    This publication includes 86 composite data products (CDPs) produced for next generation hydrogen stations, with data through the fourth quarter of 2016. These CDPs include data from retail stations only.

  19. Next Generation Hydrogen Station Composite Data Products: Retail Stations, Data through Quarter 2 of 2017

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Samuel [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer M [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Christopher D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael C. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-12-05

    This publication includes 92 composite data products (CDPs) produced for next generation hydrogen stations, with data through the second quarter of 2017. These CDPs include data from retail stations only.

  20. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Hvitved-Jacobsen, T.

    This report for the 2000 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unique basis for projects dealin...

  1. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Schaarup-Jensen, Kjeld

    This report for the 1999 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unigue basis for projects dealin...

  2. Operational radio interferometry observation network (ORION) mobile VLBI station. [for NASA Crustal Dynamics Project

    Science.gov (United States)

    Renzetti, N. A.; Vegos, C. J.; Parks, G. S.; Sniffin, R. W.; Gannon, D. L.; Nishimura, H. G.; Clements, P. A.; Mckinney, R. P.; Menninger, F. J.; Vandenberg, N. R.

    1983-01-01

    The design and current status of the ORION mobile VLBI station is described. The station consists of a five-meter antenna, a receiving and recording system installed in a mobile antenna transporter, and an electronics transporter. The station is designed for field operation by a two-person crew at the rate of two sites per week. The various subsystems are described in detail, including the antenna, housing facilities for electronics and crew, microwave equipment, receiver, data acquisition subsystem, frequency and timing subsystem, phase calibration, monitoring and control, water vapor radiometer, and communications.

  3. Beaver Valley Power Station and Shippingport Atomic Power Station. 1984 Annual environmental report, radiological. Volume 2

    International Nuclear Information System (INIS)

    1985-01-01

    This report describes the Radiological Environmental Monitoring Program conducted during 1984 in the vicinity of the Beaver Valley Power Station and the Shippingport Atomic Power Station. The Radiological Environmental Program consists of on-site sampling of water and gaseous effluents and off-site monitoring of water, air, river sediments, soils, food pathway samples, and radiation levels in the vicinity of the site. This report discusses the results of this monitoring during 1984. The environmental program outlined in the Beaver Valley Power Station Technical Specifications was followed throughout 1984. The results of this environmental monitoring program show that Shippingport Atomic Power Station and Beaver Valley Power Station operations have not adversely affected the surrounding environment. 23 figs., 18 tabs

  4. Interior Alaska Gravity Station Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The gravity station data total 9416 records. This data base was received in March 1997. Principal gravity parameters include Free-air Anomalies which have been...

  5. Gravity Station Data for Spain

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The gravity station data total 28493 records. This data base was received in April 1997. Principal gravity parameters include Free-air Anomalies which have been...

  6. Gravity Station Data for Portugal

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The gravity station data total 3064 records. This data base was received in April 1997. Principal gravity parameters include Free-air Anomalies which have been...

  7. 47 CFR 80.123 - Service to stations on land.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Service to stations on land. 80.123 Section 80... STATIONS IN THE MARITIME SERVICES Operating Requirements and Procedures Special Procedures-Public Coast Stations § 80.123 Service to stations on land. Marine VHF public coast stations, including AMTS coast...

  8. Review of freeboard: Grand Rapids Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Groeneveld, J.L.; Harding, W.B.; Bonin, D.V.; Fuchs, D.M. [Acres Manitoba Ltd., Winnipeg, MB (Canada); Warner, B.J. [Manitoba Hydro, Winnipeg, MB (Canada)

    2001-10-01

    Constructed during the period 1960-1965, the Grand Rapids Generating Station is a 472 MW hydroelectric station located approximately 400 kilometres northwest of Winnipeg, Manitoba, on the Saskatchewan River. An intake structure, four penstocks, a four-unit plus house unit powerhouse, wing walls, extensive dyke structures and a four-bay spillway are the components of the generating station. A little over ten years ago, the Manitoba Hydro Dam Safety Program was initiated. The program included a detailed dam safety review of the Grand rapids Generating Station. A potential deficiency in the freeboard allowance for several of the earthen dykes was revealed by the review process. The dam safety guidelines sponsored by the Canadian Dam Association were not met. The occurrence of a 1:1000 year wind event from the critical direction when the reservoir was at or near its full supply level was compounded by the analysis. The establishment of a wind and wave monitoring program was included in the deficiency studies commissioned. The objective was to confirm the empirical estimates concerning wave height, the development and usage of a two dimensional numerical wave model, and additional freeboard analyses to refine estimates of the recurrence interval of the current level of protection. A statistical Monte Carlo analysis was performed in the case of the estimates of the recurrence interval to determine the joint probabilities of seasonal variations in wind direction, wind speed, and reservoir level. The estimate of the actual risk of overtopping was therefore refined, and the details pertaining to the methodology and the conclusions of the analysis are all included in the paper. 15 refs., 4 tabs., 9 figs.

  9. Project authorization process in the thermal power stations vs in the hydroelectric power stations: two weights, two measurements?

    International Nuclear Information System (INIS)

    Comtois, Y.

    2004-01-01

    Key topics include the long tendering process, a comparison of two projects: thermal station vs. hydroelectrical station, and the solutions towards reducing the delay in obtaining authorization. (author)

  10. Nuclear power plant remote monitoring system of Hessen (KFUe Hessen) now fully available

    International Nuclear Information System (INIS)

    Lettmann, W.; Merkel, M.

    1991-01-01

    The remote monitoring system for the Biblis nuclear power station has commenced operation in 1990. It is intended to provide the radiological data and other information required by the supervisory Land authority for performing its supervisory functions in accordance with the Atomic Energy Act. The monitoring station records and reports emissions of the reactor station during specified normal operation and as a result of incidents or accidents, measures local dose rates at four measuring stations at the power plant fence, and records the meteorological conditions. The system is explained in detail, including illustration and graphs. (BBR) [de

  11. Elements of an advanced integrated operator control station

    International Nuclear Information System (INIS)

    Clarke, M.M.; Kreifeldt, J.G.

    1984-01-01

    One of the critical determinants of performance for any remotely operated maintenance system is the compatibility achieved between elements of the man/machine interface (e.g., master manipulator controller, controls, displays) and the human operator. In the remote control engineering task of the Consolidated Fuel Reprocessing Program, considerable attention has been devoted to optimizing the man/machine interface of the operator control station. This system must be considered an integral element of the overall maintenance work system which includes transporters, manipulators, remote viewing, and other parts. The control station must reflect the integration of the operator team, control/display panels, manipulator master controllers, and remote viewing monitors. Human factors principles and experimentation have been used in the development of an advanced integrated operator control station designed for the advance servomanipulator. Key features of this next-generation design are summarized in this presentation. 7 references, 4 figures

  12. Elements of an advanced integrated operator control station

    International Nuclear Information System (INIS)

    Clarke, M.M.; Kreifeldt, J.G.

    1984-01-01

    One of the critical determinants of peformance for any remotely operated maintenance system is the compatibility achieved between elements of the man/machine interface (e.g., master manipulator controller, controls, displays, etc.) and the human operator. In the Remote Control Engineering task of the Consolidated Fuel Reprocessing Program, considerable attention has been devoted to optimizing the man/machine interface of the operator control station. This system must be considered an integral element of the overall maintenance work system which includes transporters, manipulators, remote viewing, and other parts. The control station must reflect the integration of the operator team, control/display panels, manipulator master controllers, and remote viewing monitors. Human factors principles and experimentation have been used in the development of an advanced integrated operator control station designed for the advance servomanipulator. Key features of this next-generation design are summarized in this presentation. 7 references, 4 figures

  13. Variability of benzene exposure among filling station attendants

    International Nuclear Information System (INIS)

    Carere, A.; Iacovella, N.; Turrio Baldassarri, L.; Fuselli, S.; Iavarone, I.; Lagorio, S.; Proietto, A.R.

    1996-12-01

    A monitoring survey of filling station attendants aimed at identifying sources of variability of exposure to benzene and other aromatics was carried out. Concurrent samples of the worker's breathing zone air, atmospheric air in the service station proximity, and gasoline were collected, along with information about daily workloads and other exposure-related factors. Benzene personal exposure was characterised by a small between-worker variability and a predominant within-worker variance component. Such elevated day-to-day variability yields to imprecise estimates of mean personal exposure. Almost 70% of the overall personal exposure variance was explained by a model including daily benzene from dispensed fuel, presence of a shelter over the refueling area, amount of fuel supplied to the station if a delivery occurred, and background atmospheric benzene concentration

  14. Monitoring and diagnosis of condensation systems in thermoelectric power stations: behavior indicators; Monitoreo y diagnostico de sistemas de condensacion en centrales termoelectricas: indicadores de comportamiento

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Martinez, Hugo; Sanchez Sanchez, Ramon [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2009-07-01

    In this article are described the basic characteristics, capacities and benefits of a computer system for the monitoring and operation diagnosis of the main equipment of a condensation system of thermoelectric power plants. The system monitors the process variables in real time and, with base in these variables, it can realize a diagnosis of the cooling tower, the condenser, the circulation water and the circulating water pumps, deducting the possible problems (deficiency causes) and raising alternatives to improve the system performance or to solve the problem. It is important to mention that with base in the raised alternatives, the user can take decisions to diminish or eliminate the problem. The essential content of the article focuses in the description of the basic procedures for the calculation of the performance and diagnosis indicators of the condensation system of the equipment. The equipment evaluation is carried out by means of the comparison between the indicators values and the expected ones, whereas the diagnosis is realized by means of an expert system. [Spanish] En este articulo se describen las caracteristicas principales, capacidades y beneficios de un sistema computacional para el monitoreo y diagnostico del funcionamiento de los equipos principales de un sistema de condensacion de plantas termoelectricas. El sistema monitorea las variables del proceso en tiempo real y, con base en dichas variables, puede realizar un diagnostico de la torre de enfriamiento, el condensador y las bombas de agua de circulacion, deduciendo los posibles problemas (causas de las deficiencias) y planteando alternativas para mejorar el desempeno del sistema o solucionar el problema. Es importante mencionar que con base en las alternativas planteadas, el usuario puede tomar decisiones para reducir o eliminar el problema. El contenido esencial del articulo se enfoca en la descripcion de los procedimientos basicos para el calculo de los indicadores de desempeno y

  15. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; GUPPY,J.G.

    1998-09-01

    This is the final report on the INSP project entitled, ``Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant.

  16. Monitoring the residual life of atomic power station equipment based on the indices of stress-corrosion strength of constructional materials

    International Nuclear Information System (INIS)

    Stepanov, I.A.

    1994-01-01

    The properties of a constructional material determining life are strength, plasticity, and crack resistance. Loss of properties occurs as the result of corrosion, temperature action, actual and residual stresses, and neutron and gamma-radiation. Corrosion leads to a decrease in thickness, loss of density, changes in the composition and structure of the surface layers, and a reduction in strength, plasticity, and crack resistance of constructional materials. The influence of temperature on the loss of properties of materials is revealed as possible phase and structural transformations of the metal and the surface layers and a reduction in the stress-rupture, plastic, and thermal-fatigue properties. The actual and residual stresses not only strengthen the influence of corrosive media but also directly determine the stress-rupture strength and cyclic life. The influence of neutron and gamma-radiation is based o the change in composition of the corrosive medium (radiolysis), radiation embrittlement of the material, and the change in properties of the surface and oxide layers. The authors discuss the concepts and design of automated monitoring systems for determining the fitness of the components of on atomic power plant

  17. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    International Nuclear Information System (INIS)

    GREENE, G.A.; GUPPY, J.G.

    1998-01-01

    This is the final report on the INSP project entitled, ''Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant

  18. Modular integrated video system (MIVS) review station

    International Nuclear Information System (INIS)

    Garcia, M.L.

    1988-01-01

    An unattended video surveillance unit, the Modular Integrated Video System (MIVS), has been developed by Sandia National Laboratories for International Safeguards use. An important support element of this system is a semi-automatic Review Station. Four component modules, including an 8 mm video tape recorder, a 4-inch video monitor, a power supply and control electronics utilizing a liquid crystal display (LCD) are mounted in a suitcase for probability. The unit communicates through the interactive, menu-driven LCD and may be operated on facility power through the world. During surveillance, the MIVS records video information at specified time intervals, while also inserting consecutive scene numbers and tamper event information. Using either of two available modes of operation, the Review Station reads the inserted information and counts the number of missed scenes and/or tamper events encountered on the tapes, and reports this to the user on the LCD. At the end of a review session, the system will summarize the results of the review, stop the recorder, and advise the user of the completion of the review. In addition, the Review Station will check for any video loss on the tape

  19. Study of the active layer at the Spanish Antarctic station “Gabriel de Castilla”, Deception Island, Antarctica

    International Nuclear Information System (INIS)

    Pablo, M.A. de; Molina, A.; Recio, C.; Ramos, M.; Goyanes, G.; Ropero, M.A.

    2017-01-01

    The degradation of permanent frozen ground (permafrost) and the increase in the thickness of the active layer may be caused both by natural processes (such as global climate change) and by anthropic activity, which changes the natural environmental conditions that allow its existence, as has been widely reported to occur in the northern polar and subpolar regions. In the case of Antarctica, some scientific research stations are located in areas with permafrost, such as the Spanish Antarctic station “Gabriel de Castilla” on Deception Island. In the place where the station is located, an important increase in erosion has been observed in recent years, including the excavation of new gullies and the erosion of the coastal cliffs. In order to develop an initial analysis of the possible effects of the station on the permafrost degradation, ground temperature has been monitored since 2012 and the thickness and of the active layer and the temperature, both inside and beneath the station, have also been sporadically measured. Here we show the results and discuss how the station reduces the freezing of the ground during the winter when the station is closed and facilitates the warming of the ground during the living periods of the station in the Antarctic summer. Those initial results and conclusions make necessary to continue the study of the permafrost and the active layer in the station site by systematic monitoring of the ground temperature and the thickness of the active layer. [es

  20. Development and application of a low-cost, portable DOAS system for stratospheric composition monitoring over the Argentinean Patagonia and Antarctic stations.

    Science.gov (United States)

    Raponi, Marcelo; Jiménez, Rodrigo; Ristori, Pablo; Wolfram, Elian; Tocho, Jorge; Quel, Eduardo

    2010-05-01

    A significant fraction of the Argentinean population is seasonally exposed to elevated UV radiation, particularly during severe stratospheric ozone destruction episodes in Antarctica. In order to provide early alert, global monitoring and to improve our understanding of these phenomena, various Argentinean and international organizations maintain stratospheric composition remote sensing sites from the southern tip of Argentina (Patagonia) to Antarctica. The understating of the ozone destruction dynamics will be significantly improved if more sites were available. For instance, the Laser and Applications Research Center, CEILAP (CITEFA-CONICET, Argentina) carries out systematic measurements of stratospheric ozone and tropospheric water vapor profiles at Rio Gallego (51° 36' S, 69° 19' W, 15 m asl) by means of LIDAR systems. Besides the active systems, the site possesses different passive instruments (GUV-541, UV-B and UV-A radiometers, SAOZ spectrometer, CIMEL sunphotometer) all of them working in synergy. The goal of this work is to present the design and development of a new compact atmospheric remote sensing system, able to determine the vertical column concentration in column (VCD) of multiple trace gases. We have developed a low-cost, portable passive DOAS system, ERO-DOAS, wich circumvents the cost limitations associated with new fixed monitoring sites. It is composed of commercial spectrophotometer (HR4000, Ocean Optics), a 400-μm core, 6-m long optic fiber, and a home-made automatic external shutter. We have developed a LabVIEW® based software for spectrometer/shutter control and data acquisition, and a MATLAB® based software for spectral data reduction. In the work we highlight the main characteristics of the system's components and we describe the visual interface implemented to controls the operation of the whole system, and the calculation algorithms to process the measured zenithal spectra, postulating the strategies implemented to solve the

  1. Wind turbine power stations

    International Nuclear Information System (INIS)

    Anon.

    1992-11-01

    The Countryside Council for Wales (CCW's) policy on wind turbine power stations needs to be read in the context of CCW's document Energy:Policy and perspectives for the Welsh countryside. This identifies four levels of action aimed at reducing emission of gases which contribute towards the risk of global warming and gases which cause acid deposition. These are: the need for investment in energy efficiency; the need for investment in conventional power generation in order to meet the highest environmental standards; the need for investment in renewable energy; and the need to use land use transportation policies and decisions to ensure energy efficiency and energy conservation. CCW views wind turbine power stations, along with other renewable energy systems, within this framework. CCW's policy is to welcome the exploitation of renewable energy sources as an element in a complete and environmentally sensitive energy policy, subject to the Environmental Assessment of individual schemes and monitoring of the long-term impact of the various technologies involved. (Author)

  2. Chilean Antarctic Stations on King George Island

    Directory of Open Access Journals (Sweden)

    Katsutada Kaminuma

    2000-07-01

    Full Text Available The purpose of my visit to Chilean Antarctic Stations was to assess the present status of geophysical observations and research, as the South Shetland Island, West Antarctica, where the stations are located, are one of the most active tectonic regions on the Antarctic plate. The Instituto Antartico Chileno (INACH kindly gave me a chance to stay in Frei/Escudero Bases as an exchange scientist under the Antarctic Treaty for two weeks in January 2000. I stayed in Frei Base as a member of a geological survey group named "Tectonic Evolution of the Antarctic Peninsula" which was organized by Prof. F. Herve, University of Chile, from January 05 to 19,2000. All my activity in the Antarctic was organized by INACH. During my stay in Frei Base, I also visited Bellingshausen (Russian, Great Wall (China and Artigas (Uruguay stations. All these stations are located within walking distance of Frei Base. King Sejong Station (Korea, located 10km east from Frei Base, and Jubany Base (Argentine, another 6km south-east from King Sejong Station, were also visited with the aid of a zodiac boat that was kindly operated for us by King Sejong Station. All stations except Escudero Base carry out meteorological observations. The seismological observations in Frei Base are operated by Washington State University of the U. S. monitoring of earthquake activity and three-component geomagnetic observations are done at King Sejong and Great Wall stations. Earth tide is monitored at Artigas Base. Continuous monitoring of GPS and gravity change are planned at King Sejong Station in the near future. Scientific research activities of each country in the area in the 1999/2000 Antarctic summer season were studied and the logistic ability of all stations was also assessed for our future international cooperation.

  3. BIOLOGICAL AND ENVIRONMENTAL RADIATION EXPERIENCE AT INDIAN POINT STATION

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, H. F.

    1963-09-15

    The environs monitoring program at Indian Point Station is presented. Thirty sampling stations within a circle of approximately 10 miles of the station are used for the collection of samples of air, water, vegetation, and soil that are then analyzed for gross beta-gamma activity. Data are tabulated. (P.C.H.)

  4. Fortaleza Station Report for 2012

    Science.gov (United States)

    Kaufmann, Pierre; Pereira de Lucena, A. Macilio; Sombra da Silva, Adeildo

    2013-01-01

    This is a brief report about the activities carried out at the Fortaleza geodetic VLBI station (ROEN: R´adio Observat´orio Espacial do Nordeste), located in Eus´ebio, CE, Brazil, during the period from January until December 2012. The observing activities were resumed in May after the major maintenance that comprised the azimuth bearing replacement. The total observational experiments consisted of 103 VLBI sessions and continuous GPS monitoring recordings.

  5. Proton irradiation experiment for x-ray charge-coupled devices of the monitor of all-sky x-ray image mission onboard the international space station. 2. Degradation of dark current and identification of electron trap level

    CERN Document Server

    Miyata, E; Kamiyama, D

    2003-01-01

    We have investigated the radiation damage effects on a charge-coupled device (CCD) to be used for the Japanese X-ray mission, the monitor of all-sky X-ray image (MAXI), onboard the international space station (ISS). A temperature dependence of the dark current as a function of incremental dose is studied. We found that the protons having energy of >292 keV seriously increased the dark current of the devices. In order to improve the radiation tolerance of the devices, we have developed various device architectures to minimize the radiation damage in orbit. Among them, nitride oxide enables us to reduce the dark current significantly and therefore we adopted nitride oxide for the flight devices. We also compared the dark current of a device in operation and that out of operation during the proton irradiation. The dark current of the device in operation became twofold that out of operation, and we thus determined that devices would be turned off during the passage of the radiation belt. The temperature dependenc...

  6. The use of vertical and horizontal surface displacements at EPOS GNSS stations in Greenland to study ice sheet mass balance

    DEFF Research Database (Denmark)

    Khan, Shfaqat Abbas

    2014-01-01

    The European Plate Observing System (EPOS) includes e.g. seismic and geodetic permanent national monitoring networks on a European scale. The main purpose is to create data platforms for monitoring and study geophysics processes like earthquakes, volcanoes, surface dynamics and tectonics. Here we...... present data from arctic GNSS stations included in the EPOS network. The arctic EPOS GNSS network consists of 16 continuous GPS stations spread across Greenland. This network is able to map the velocity fields associated with, plate motion, postglacial rebound and improve our understanding of tectonic...

  7. Arduino adventures escape from Gemini station

    CERN Document Server

    Kelly, James Floyd

    2013-01-01

    Arduino Adventures: Escape from Gemini Station provides a fun introduction to the Arduino microcontroller by putting you (the reader) into the action of a science fiction adventure story.  You'll find yourself following along as Cade and Elle explore Gemini Station-an orbiting museum dedicated to preserving and sharing technology throughout the centuries. Trouble ensues. The station is evacuated, including Cade and Elle's class that was visiting the station on a field trip. Cade and Elle don't make it aboard their shuttle and are trapped on the station along with a friendly artificial intellig

  8. Radiation monitoring around accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Shinichi [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan)

    2000-07-01

    The present status of a network of radiation monitors (NORM) working at KEK is described in detail. NORM consists of there parts; stand-alone radiation monitors (SARM), local-monitoring stations (STATION) and a central data-handling system (CENTER). NORM has developed to a large-scaled monitoring system in which more than 250 SARMs are under operation for monitoring the radiation fields and radioactivities around accelerators in KEK. (author)

  9. PlayStation purpura.

    Science.gov (United States)

    Robertson, Susan J; Leonard, Jane; Chamberlain, Alex J

    2010-08-01

    A 16-year-old boy presented with a number of asymptomatic pigmented macules on the volar aspect of his index fingers. Dermoscopy of each macule revealed a parallel ridge pattern of homogenous reddish-brown pigment. We propose that these lesions were induced by repetitive trauma from a Sony PlayStation 3 (Sony Corporation, Tokyo, Japan) vibration feedback controller. The lesions completely resolved following abstinence from gaming over a number of weeks. Although the parallel ridge pattern is typically the hallmark for early acral lentiginous melanoma, it may be observed in a limited number of benign entities, including subcorneal haematoma.

  10. Reevaluation of air surveillance station siting

    International Nuclear Information System (INIS)

    Abbott, K.; Jannik, T.

    2016-01-01

    DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

  11. Reevaluation of air surveillance station siting

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jannik, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-07-06

    DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

  12. The Trencin water power station

    International Nuclear Information System (INIS)

    2005-01-01

    This leaflet describes the Trencin water power station. The Trencin water power station was built seven years after the Dubnica nad Vahom water power station started its operation and was the last stage of the first and the oldest derived cascade of water power stations on the Vah River. After completing water power stations at Ladce (1936), Ilava (1946) and Dubnica nad Vahom (1949) and before constructing the Trencin water power station, the whole second derived cascade of water power stations including water power stations at Kostolna, Nove Mesto nad Vahom and Horna Streda was built as soon as possible mainly because the need to get compensation for discontinued electricity supplies as well as energetic coal from the Czech Republic. Hereby, experiences from the construction of previous grades were used, mainly as far as the dimensioning was concerned, as the fi rst installed power stations had, in comparison with the growing requirements on the electricity supplies, very low absorption capacity - only 150 m 3 .s -1 . Thus the Trencin power station (original name was the Skalka power station) was already dimensioned for the same absorption capacity as the cascade located downstream the river, that is 180 m 3 .s -1 . That was related also to growing demands on electricity supplies during the peaks in the daily electric system load diagram, and thus to the transfer from continuous operation of the water power station to semi-peak or even peak performance. According to the standards of power station classification, the Trencin water power station is a medium size, low pressure, channel power station with two units equipped by Kaplan turbines and synchronous hydro-alternators. The water power station installed capacity is 16.1 MW in total and its designed annual production of electrical energy for medium water year is 85,000 MWh, while the average annual production during the last 30 years is 86,252 MWh. Installed unit has a four-blade Kaplan turbine with the diameter

  13. Evaluating the radiation environment around a nuclear power station with unmonitored radionuclide release

    International Nuclear Information System (INIS)

    Bondarev, A.A.; Dibobes, I.K.; Pyuskyulan, K.I.

    1986-01-01

    This paper describes the radiation monitoring system at (RMS) at the Armenian nuclear power station; the environmental monitoring program includes measuring the gamma radiation around the station, determining radionuclide contents in air and fallout, and also in surface water and ground water, in water plants and bottom sediments, in soil and plants and also in local agricultural products. The RMS monitors gas-aerosol releases and effluents from the station. The radius of the monitored zone is 25 km. The gamma radiation is measured by IKS dosemeters and SRP-68-01 portable instruments. The air is monitored by six stationary aspriation systems at distances of 1, 5, 6, 11, 14, 15 and 50 km and 28 planchette cells. The RMS records virtually all the mean monthly and mean annual fluctuations in the global background. In seven years of operation at the Armenian station, only Ca 137 and Sr 90 from global fallout together with Be 7 of cosmogenic origin have been observed in air apart from two cases. In 1981, air samples taken with the aspirators and combined over a quarter showed Ce 141, Ce 144, Ru 106, Ru 103, Nb 95 and Zr 95. The concentrations of these are presented

  14. NASA space station automation: AI-based technology review

    Science.gov (United States)

    Firschein, O.; Georgeff, M. P.; Park, W.; Neumann, P.; Kautz, W. H.; Levitt, K. N.; Rom, R. J.; Poggio, A. A.

    1985-01-01

    Research and Development projects in automation for the Space Station are discussed. Artificial Intelligence (AI) based automation technologies are planned to enhance crew safety through reduced need for EVA, increase crew productivity through the reduction of routine operations, increase space station autonomy, and augment space station capability through the use of teleoperation and robotics. AI technology will also be developed for the servicing of satellites at the Space Station, system monitoring and diagnosis, space manufacturing, and the assembly of large space structures.

  15. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  16. Hydrogen Station Cost Estimates: Comparing Hydrogen Station Cost Calculator Results with other Recent Estimates

    Energy Technology Data Exchange (ETDEWEB)

    Melaina, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Penev, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-09-01

    This report compares hydrogen station cost estimates conveyed by expert stakeholders through the Hydrogen Station Cost Calculation (HSCC) to a select number of other cost estimates. These other cost estimates include projections based upon cost models and costs associated with recently funded stations.

  17. R2 Water Quality Portal Monitoring Stations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on...

  18. Reconfigurable assembly work station

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yhu-Tin; Abell, Jeffrey A.; Spicer, John Patrick

    2017-11-14

    A reconfigurable autonomous workstation includes a multi-faced superstructure including a horizontally-arranged frame section supported on a plurality of posts. The posts form a plurality of vertical faces arranged between adjacent pairs of the posts, the faces including first and second faces and a power distribution and position reference face. A controllable robotic arm suspends from the rectangular frame section, and a work table fixedly couples to the power distribution and position reference face. A plurality of conveyor tables are fixedly coupled to the work table including a first conveyor table through the first face and a second conveyor table through the second face. A vision system monitors the work table and each of the conveyor tables. A programmable controller monitors signal inputs from the vision system to identify and determine orientation of the component on the first conveyor table and control the robotic arm to execute an assembly task.

  19. Environmental monitoring networks in Spain; Redes de vigilancia radiologica ambiental en Espana

    Energy Technology Data Exchange (ETDEWEB)

    Luque Heredia, S.; Martin Matarranz, J. L.; Marugan Tovar, I.; Rey del Castillo, C.; Salas Collantes, R.; Sterling Carmona, A.; Ramos Salvador, L. M.

    2011-07-01

    Environmental monitoring in Spain is carried out by several networks with different objectives and scope, a monitoring network in the vicinity of nuclear facilities and radioactive nuclear fuel cycle and various monitoring networks nationally funded and managed by agencies public. The aim of this paper is to present a summary of all monitoring networks, including a series of figures with the stations that are, their geographical distribution and the programs in them.

  20. Reference Climatological Stations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Reference Climatological Stations (RCS) network represents the first effort by NOAA to create and maintain a nationwide network of stations located only in areas...

  1. Streamflow Gaging Stations

    Data.gov (United States)

    Department of Homeland Security — This map layer shows selected streamflow gaging stations of the United States, Puerto Rico, and the U.S. Virgin Islands, in 2013. Gaging stations, or gages, measure...

  2. Fire Stations - 2007

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Station Locations in Kansas Any location where fire fighters are stationed at or based out of, or where equipment that such personnel use in carrying out their...

  3. Hammond Bay Biological Station

    Data.gov (United States)

    Federal Laboratory Consortium — Hammond Bay Biological Station (HBBS), located near Millersburg, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). HBBS was established by...

  4. Water Level Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Images contain station history information for 175 stations in the National Water Level Observation Network (NWLON). The NWLON is a network of long-term,...

  5. Weather Radar Stations

    Data.gov (United States)

    Department of Homeland Security — These data represent Next-Generation Radar (NEXRAD) and Terminal Doppler Weather Radar (TDWR) weather radar stations within the US. The NEXRAD radar stations are...

  6. Big Game Reporting Stations

    Data.gov (United States)

    Vermont Center for Geographic Information — Point locations of big game reporting stations. Big game reporting stations are places where hunters can legally report harvested deer, bear, or turkey. These are...

  7. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  8. Fire Stations - 2009

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Stations in Kansas Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their jobs is...

  9. Newport Research Station

    Data.gov (United States)

    Federal Laboratory Consortium — The Newport Research Station is the Center's only ocean-port research facility. This station is located at Oregon State University's Hatfield Marine Science Center,...

  10. Intertidal ecology of the sea shore near Tarapur Atomic Power Station

    International Nuclear Information System (INIS)

    Balani, M.C.

    1975-01-01

    Surveys were carried out between March 1969 and August 1970 to study the fauna and flora in the littoral zone of the sea shore near the Tarapur Atomic Power Station. The beach adjacent to the Station is rocky with a number of tidal pools inhabited by a variety of organisms whereas the beach to the south is mostly sandy and barren except for a small rocky stretch. The tidal range is 6 m and over a mile of beach is exposed during low tide. The near shore currents are very strong and have a clear northsouth oscillation with the changing tides. Less Atherina sp. fry were available near the Power Station in March 1970 than during the previous year. Possible reasons for these differences are discussed, including the effect of heated discharges on biota. The need is also emphasized to monitor the biota (Plankton, Nekton and Benthos) systematically for content of fission products released by the Power Station. (auth.)

  11. Design and Implementation of a Smart Weather Station Based on Internet of Things

    Directory of Open Access Journals (Sweden)

    Mahmoud Shaker Nasr

    2017-08-01

    Full Text Available Real-time monitoring has become a crucial thing in light of a huge growing in the number of plants and cars in Iraqi cities including the city of Babylon which leading to increase the air pollution that leads to growing the number of people suffering from cancer and other diseases. Therefore, The Weather Station is proposed to monitor specific environmental elements in the Babylon city. A number of Internet of Things (IoT technologies have been used to form the proposed system. Wireless Sensor Network (WSN and Ethernet are the main technologies that are utilized with the proposed station. The design of the Weather Station consists of three parts: Hardware, Software and Web application. The Web APP is designed using JavaScript, AJAX, PHP, HTML, CSS, and MYSQL. This Web app has been shared on the public server to be accessed by authorized persons from anywhere around the world.

  12. Extending the GEMINI advanced review station development

    International Nuclear Information System (INIS)

    Kadner, S.; Spahn, W.; Pepper, S.

    1999-01-01

    Recent changes in the objectives of arms control agreements will have a dramatic impact on the nuclear non-proliferation regime. Meeting the demands of the nuclear non-proliferation regime will require the utilisation of the best available technological means for verification. The following discussion focuses on the increasing demands for safeguards with a view towards the possible technological solutions available to meet these demands. Based on the assumption that the gap between the international nonproliferation verification agenda and the available financial means can only be bridged via technology, the following discussion hopes to offer a compelling argument for the adoption of remote monitoring technologies in safeguards applications, specifically, data collection and review. The GEMINI Advanced Review Station (GARS) was developed with initial support from USPOTAS. This poster presentation presents the latest developments in GARS, including its extension to other surveillance systems under IAEA consideration, NDA applications, and networked safeguards. (author)

  13. Core exit thermocouple upgrade at Zion station

    International Nuclear Information System (INIS)

    Ulinski, T.M.; Ferg, D.A.

    1989-01-01

    Following the Three Mile Island accident, the ability of the core exit thermocouple (CET) system to monitor reactor core conditions and core cooling status became a requirement of the U.S. Nuclear Regulatory Commission (NRC). Since the thermocouple system at Zion station was not originally required for postaccident monitoring, Commonwealth Edison Company (CECo) committed to upgrading the CET system and to installing a subcooling margin monitoring (SMM) system. The significance of this commitment was that CECo proposed to accomplish the upgrade effort using internal resources and by developing the required in-house expertise instead of procuring integrated packages from several nuclear steam supply system vendors. The result was that CECo was able to demonstrate a number of new capabilities and unique design features with a significant cost savings. These included a qualified connector with an integral thermocouple cold-reference junction temperature compensation; the design, assembly, testing, and installation of a seismically qualified class 1E microprocessor; a commercial-grade dedication/upgrade process for safety-related hardware; a human factors review capability, and a verification and validation program for safety-related software. A discussion of these new capabilities and details of the design features is presented in this paper

  14. CDIP Station Data Collection - All Stations

    Data.gov (United States)

    Scripps Institution of Oceanography, UC San Diego — The Coastal Data Information Program's station data collection consists of all publicly-released coastal environment measurements taken over the program's history, a...

  15. A study of wet deposition of atmospheric tritium releases at the Ontario Power Generation, Pickering Nuclear Generating Station

    International Nuclear Information System (INIS)

    Crooks, G.; DeWilde, J.; Yu, L.

    2001-01-01

    The Ontario Power Generation,Pickering Nuclear Generating Station (PNGS) has been investigating deposition of atmospheric releases of tritium on their site. This study has included numerical dispersion modelling studies conducted over the past three years, as well as an ongoing field monitoring study. The following paper will present results of the field monitoring study and make comparisons to the numerical modelling. The results of this study could be of potential use to nuclear stations in quantifying tritium deposition in near field regions where building wake effects dominate pollutant dispersion

  16. Monitoring large rotating machines at EDF

    International Nuclear Information System (INIS)

    Chevalier, R.; Bourgeois, P.; Le Reverend, D.

    1992-09-01

    At Electricite de France (EDF), since 1978, the operating instruments which ensure the DETECTION function, have been completed on turbogenerators by a specialized ''off-line'' vibration monitoring system, which allows a posteriori DIAGNOSIS analysis. However because of a need of a real time and more elaborated DETECTION function, the concept of the Monitoring and Diagnosis Aid Station (Poste de Surveillance et d'Aide au Diagnostic: PSAD) has been developed. It federates the processing of monitoring, organized into several functions, and includes the monitoring of turbogenerators (TGS) and reactor coolant pumps (RCP). The purpose of this paper is to present, on the one hand, the monitoring functions of TGS and RCP and on the other, the first experimental results on the behaviour of three RCP, obtained through a SAMT (Surveillance Automatisee des Machines Tournantes - Automatic monitoring of rotating machines) prototype. (authors). 2 figs., 4 tabs., 4 refs

  17. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley Low-Level Waste Collection and Transfer System upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-10-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements. Portions of the LLW system are several decades old, or older, and do not comply with current environmental protection regulations. Several subsystems of the LLW system have been designated to receive a state-of-the-art replacement and refurbishment. One such subsystem serves Building 2026, the High Radiation Level Analytical Laboratory. This assessment focuses on the scope of work for the Building 2026 replacement LLW Collection and Transfer System, including the provision of a new Monitoring and Control Station (Building 2099) to receive, store, and treat (adjust pH) low level radioactive waste

  18. "Artificial intelligence" at streamgaging stations

    Science.gov (United States)

    R. B. Thomas

    1985-01-01

    Two types of problems are related to collecting hydrologic data at stream gaging stations. One includes the technical/logistical questions associated with measuring and transferring data for processing. Effort spent on these problems ranges from improving devices for sensing data to using electronic data loggers.

  19. Performance of Existing Hydrogen Stations

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Samuel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurtz, Jennifer M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ainscough, Christopher D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Peters, Michael C [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-01

    In this presentation, the National Renewable Energy Laboratory presented aggregated analysis results on the performance of existing hydrogen stations, including performance, operation, utilization, maintenance, safety, hydrogen quality, and cost. The U.S. Department of Energy funds technology validation work at NREL through its National Fuel Cell Technology Evaluation Center (NFCTEC).

  20. Bradwell Nuclear Power Station

    International Nuclear Information System (INIS)

    1987-01-01

    When built, the Magnox reactors were expected to have operating lifetimes of 20-25 years. In order to satisfy the licensing authorities of their continued safety, long term safety reviews (LTSRs) are being carried out as the reactors reach 20 years of operation. This is the Nuclear Installations Inspectorate's (NII) summary report on Bradwell nuclear power station. The objectives of the LTSR are stated. A description of the plant is followed by an explanation of the statutory position on licensing. The responsibilities of the Central Electricity Generating Board (CEGB) and the NII are defined. From the examination of the CEGB's LTSR it is concluded that this generally confirms the validity of the existing safety case for present operation. However, some recommendations are made as to work required for reactor operation up to 1992. A summary of the NII findings is presented. This includes the reactor pressure circuit integrity, effects of ageing and in-service wear and radiation doses. (U.K.)

  1. Shippingport Station decommissioning project overview

    International Nuclear Information System (INIS)

    Schreiber, J.J.

    1985-01-01

    The U.S. Department of Energy is in the process of decommissioning the Shippingport Atomic Power Station located on the Ohio River, 30 miles northwest of Pittsburgh, Pennsylvania. The Shippingport Station is the first commercial size nuclear power plant to undergo decommissioning in the United Staes. The plant is located on approximately 7 acres of land owned by the Duquesne Light Company (DLC) and leased to the U.S. Government. DLC operates two nuclear power plants, Beaver Valley 1 and 2, located immediately adjacent to the site and the Bruce Mansfield coal-fired power plant is also within the immediate area. The Station was shutdown in October, 1982. Defueling operations began in 1983 and were completed by September, 1984. The Shippingport Station consists of a 275' x 60' fuel handling building containing the reactor containment chamber, the service building, the turbine building, the radioactive waste processing building, the administration building and other smaller support buildings. The Station has four coolant loops and most of the containment structures are located below grade. Structures owned by the U.S. Government including the fuel handling building, service building, contaminated equipment room, the boiler chambers, the radioactive waste processing building and the decontamination and laydown buildings will be dismantled and removed to 3 feet below grade. The area will then be filled with clean soil and graded. The turbine building, testing and training building and the administration building are owned by DLC and will remain

  2. Non-Coop Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Station history documentation for stations outside the US Cooperative Observer network. Primarily National Weather Service stations assigned WBAN station IDs. Other...

  3. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  4. National Coral Reef Monitoring Program: Benthic Cover Derived from Analysis of Benthic Images Collected for Climate Stations across the Hawaiian Archipelago from 2013-07-12 to 2013-10-30 (NCEI Accession 0157720)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  5. National Coral Reef Monitoring Program: Benthic Cover Derived from Analysis of Benthic Images Collected for Climate Stations across Wake Island from 2014-03-16 to 2014-03-19 (NCEI Accession 0159145)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  6. Oceanographic Station Data and temperature profiles from bottle and XBT casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1975-08-31 to 1975-09-19 (NODC Accession 7600375)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station Data and temperature profiles were collected from bottle and XBT casts from the DOLPHIN from 31 August 1975 to 19 September 1975. Data were...

  7. Oceanographic Station Data and temperature profiles from bottle and XBT casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1975-04-17 to 1976-02-07 (NODC Accession 7600888)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station Data and temperature profiles were collected from bottle and XBT casts from the DOLPHIN from 17 April 1975 to 07 February 1976. Data were...

  8. Oceanographic Station Data and temperature profiles from bottle and XBT casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1977-01-18 to 1977-05-22 (NODC Accession 7800595)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station Data and temperature profiles were collected from bottle and XBT casts from the DOLPHIN from 18 January 1977 to 22 May 1977. Data were...

  9. Oceanographic station, temperature profiles, meteorological, and other data from bottle and XBT from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) project from 1974-01-09 to 1974-01-12 (NODC Accession 7400287)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic station, temperature profiles, meteorological, and other data were collected from bottle and XBT casts from the DOLPHIN from 09 January 1974 to 12...

  10. Oceanographic Station, temperature profiles, and other data from XBT and bottle casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1973-02-12 to 1973-03-23 (NODC Accession 7300813)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station,temperature profiles, and other data were collected from XBT and bottle casts from the DOLPHIN from 12 February 1973 to 23 March 1973. Data...

  11. Oceanographic Station, temperature profiles, and other data from XBT and bottle casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1975-01-17 to 1975-04-10 (NODC Accession 7500672)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station, temperature profiles, and other data were collected from XBT and bottle casts from the DOLPHIN from 17 January 1975 to 10 April 1975. Data...

  12. Oceanographic Station, temperature profiles, and other data from bottle and XBT casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1974-08-13 to 1974-09-18 (NODC Accession 7400814)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station, temperature profiles, and other data were collected from bottle and XBT casts from the DOLPHIN from 13 August 1974 to 18 September 1974. Data...

  13. Oceanographic Station Data and temperature profiles from XBT and bottle casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1975-12-03 to 1975-12-06 (NODC Accession 7600754)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station Data and temperature profiles were collected from XBT and bottle casts from the DOLPHIN from 03 December 1975 to 06 December 1975. Data were...

  14. Oceanographic Station, temperature profiles, and other data from XBT and bottle casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1974-04-01 to 1974-05-09 (NODC Accession 7400626)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station, temperature profiles, and other data were collected from XBT and bottle casts from the DOLPHIN from 01 April 1974 to 09 May 1974. Data were...

  15. HECO annually conducts and reports results of a biological monitoring program for waters receiving effluent from the Kahe Generating Station, O'ahu, Hawai'i from 1977 to 1996 (NODC Accession 9900012)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The volume of sand and silt entrained and circulated by operation of the Kahe Generating Station is an environmental parameter of considerable geological and...

  16. National Coral Reef Monitoring Program: Benthic Cover Derived from Analysis of Benthic Images Collected for Climate Stations across the Pacific Remote Island Areas from 2015-01-26 to 2015-04-27 (NCEI Accession 0159152)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  17. National Coral Reef Monitoring Program: benthic cover derived from analysis of benthic images collected for climate stations across the Hawaiian Archipelago from 2016-07-17 to 2016-09-21 (NCEI Accession 0164294)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data described here result from benthic photo-quadrat surveys conducted along transects at climate stations and permanent sites identified by the Ocean and...

  18. Oceanographic Station Data and temperature profiles from XBT and bottle casts from the DOLPHIN as part of the Marine Resources Monitoring, Assessment and Prediction (MARMAP) from 1976-08-28 to 1976-09-21 (NODC Accession 7700036)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Oceanographic Station Data and temperature profiles were collected from XBT and bottle casts from the DOLPHIN from 28 August 1976 to 21 September 1976. Data were...

  19. 47 CFR 32.2311 - Station apparatus.

    Science.gov (United States)

    2010-10-01

    ... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2311 Station apparatus... company shall prepare a list of station apparatus which shall be used as its list of disposition units for... technicians, and others, shall be included in Account 2114, Tools and other work equipment, Account 2220...

  20. Amtrak Rail Stations (National)

    Data.gov (United States)

    Department of Transportation — Updated database of the Federal Railroad Administration's (FRA) Amtrak Station database. This database is a geographic data set containing Amtrak intercity railroad...

  1. Cooperative Station History Forms

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Various forms, photographs and correspondence documenting the history of Cooperative station instrumentation, location changes, inspections, and...

  2. Design and engineering of a gas-engine driven heat pump heating station including heat distribution system and utilization of waste heat from an ice rink for the residential area Dorsten - Maria Lindenhof. Planung eines Gasmotor-Waermepumpenheizwerkes mit angeschlossenem Waermeverteilungsnetz und Abwaermenutzung einer Eisenbahn fuer das zentralstaedtische Gebiet 'Maria-Lindenhof' in Dorsten

    Energy Technology Data Exchange (ETDEWEB)

    Huelsemann, R.

    1984-05-01

    A gas-engine driven heat pump heating station including the required heat destribution system and utilization of waste heat from an ice rink to be realized in the residential area Dorsten - Maria Lindenhof. The total heat capacity was to be reached in two stages, corresponding to the progress of the building and housing structure in this specific area: First stage of construction 5,6 MW, final stage of construction 7,6 MW. With regard to the final stage of construction only a relatively small part of the buildings is provided with heating systems designed for supply and return temperatures of 90/70/sup 0/C respectively. The old people's home built in 1980 was already equipped with low temperature heating systems and all buildings still to be built shall be provided with low-temperature systems. As far as old heating systems are concerned, the required measures must be taken to reduce the temperature in the return lines.

  3. NOAA/EcoFOCI Chukchi Sea mooring time-series data, stations C1, C2, and C3, 2010-08-29 to 2012-08-21, including currents, temperature, salinity, oxygen, chlorophyll a, and nitrate data (NCEI Accession 0157701)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These EcoFOCI mooring time-series datasets consist of RCM-9 current data, Ecofluorometer, Seacat and nitrate data from moored instruments at 3 stations in the...

  4. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  5. Seismometer array station processors

    International Nuclear Information System (INIS)

    Key, F.A.; Lea, T.G.; Douglas, A.

    1977-01-01

    A description is given of the design, construction and initial testing of two types of Seismometer Array Station Processor (SASP), one to work with data stored on magnetic tape in analogue form, the other with data in digital form. The purpose of a SASP is to detect the short period P waves recorded by a UK-type array of 20 seismometers and to edit these on to a a digital library tape or disc. The edited data are then processed to obtain a rough location for the source and to produce seismograms (after optimum processing) for analysis by a seismologist. SASPs are an important component in the scheme for monitoring underground explosions advocated by the UK in the Conference of the Committee on Disarmament. With digital input a SASP can operate at 30 times real time using a linear detection process and at 20 times real time using the log detector of Weichert. Although the log detector is slower, it has the advantage over the linear detector that signals with lower signal-to-noise ratio can be detected and spurious large amplitudes are less likely to produce a detection. It is recommended, therefore, that where possible array data should be recorded in digital form for input to a SASP and that the log detector of Weichert be used. Trial runs show that a SASP is capable of detecting signals down to signal-to-noise ratios of about two with very few false detections, and at mid-continental array sites it should be capable of detecting most, if not all, the signals with magnitude above msub(b) 4.5; the UK argues that, given a suitable network, it is realistic to hope that sources of this magnitude and above can be detected and identified by seismological means alone. (author)

  6. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of American Samoa from 2015-02-15 to 2015-03-26 (NCEI Accession 0159143)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at National Coral Reef Monitoring Program (NCRMP)...

  7. Secure base stations

    NARCIS (Netherlands)

    Bosch, Peter; Brusilovsky, Alec; McLellan, Rae; Mullender, Sape J.; Polakos, Paul

    2009-01-01

    With the introduction of the third generation (3G) Universal Mobile Telecommunications System (UMTS) base station router (BSR) and fourth generation (4G) base stations, such as the 3rd Generation Partnership Project (3GPP) Long Term Evolution (LTE) Evolved Node B (eNB), it has become important to

  8. Meyrin Petrol Station

    CERN Multimedia

    2006-01-01

    Please note that the Meyrin petrol station will be closed for maintenance work on Tuesday 19 and Wednesday 20 December 2006. If you require petrol during this period we invite you to use the Prévessin petrol station, which will remain open. TS-IC-LO Section Tel.: 77039 - 73793

  9. Nuclear power stations licensing

    International Nuclear Information System (INIS)

    Solito, J.

    1978-04-01

    The judicial aspects of nuclear stations licensing are presented. The licensing systems of the United States, Spain, France and Federal Republic of Germany are focused. The decree n 0 60.824 from July 7 sup(th), 1967 and the following legislation which define the systematic and area of competence in nuclear stations licensing are analysed [pt

  10. SPS rectifier stations

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The first of the twelves SPS rectifier stations for the bending magnets arrived at CERN at the end of the year. The photograph shows a station with the rectifiers on the left and in the other three cubicles the chokes, capacitors and resistor of the passive filter.

  11. Ondergronds Station Blijdorp, Rotterdam

    NARCIS (Netherlands)

    Hijma, M.P.|info:eu-repo/dai/nl/266562426; Cohen, K.M.|info:eu-repo/dai/nl/185633374

    2014-01-01

    Het is in de herfst van 2005. Een lief meisje, Marieke, rijdt op haar vouwfiets door Rotterdam. Bij het Centraal Station is het al tijden een grote bouwplaats. Onder de nieuwe hal komt een veel groter metrostation en ook onder de Statenweg in Blijdorp is een grote bouwput voor een nieuw station.

  12. NNSS Soils Monitoring: Plutonium Valley (CAU 366) FY2015

    Energy Technology Data Exchange (ETDEWEB)

    Nikolich, George [Desert Research Inst. (DRI), Las Vegas, NV (United States); Mizell, Steve [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Reno, NV (United States); Campbell, Scott [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-02-01

    Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil transport from the Plutonium Valley Contamination Area (CA) as a result of wind transport and storm runoff in support of National Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the contamination areas. The DRI work is intended to confirm the likely mechanism(s) of transport and determine the meteorological conditions that might cause movement of contaminated soils. The emphasis of the work is on collecting sediment transported by channelized storm runoff at the Plutonium Valley investigation sites. These data will inform closure plans that are being developed, which will facilitate the appropriate closure design and post-closure monitoring. In 2011, DRI installed two meteorological monitoring stations south (station #1) and north (station #2) of the Plutonium Valley CA and a runoff sediment sampling station within the CA. Temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and airborne particulate concentration are collected at both meteorological stations. The maximum, minimum, and average or total (as appropriate) for each of these parameters are recorded for each 10-minute interval. The sediment sampling station includes an automatically activated ISCO sampling pump with collection bottles for suspended sediment, which is activated when sufficient flow is present in the channel, and passive traps for bedload material that is transported down the channel during runoff events. This report presents data collected from these stations during fiscal year (FY) 2015.

  13. Vessel Monitoring Systems Study. Volume I - Technical Analysis.

    Science.gov (United States)

    1980-09-01

    In the Port and Tanker Safety Act of 1978 the U.S. Conress directed the Department of Transportation to performa a study on the desirability and feasibility of a shore-station system for monitoring vessels (including fishing vessels)offshore within t...

  14. Results of Monitoring at Olkiluoto in 2010. Rock Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Lahti, M [ed.; Siren, T

    2011-12-15

    The rock mechanical monitoring at Olkiluoto concentrates on the assessment of potential tectonic movements and stability of the bedrock. The construction of ONKALO is not expected to induce large-scale movements of the rock blocks or affect the rate of isostatic uplift but the evaluation of any tectonic events is important for the safety assessment. The monitoring consists of seismic measurements, GPS measurements and precise levelling campaigns at Olkiluoto and vicinity and extensometer and convergence measurements carried out in ONKALO. Posiva established a local seismic network of six stations on the island of Olkiluoto in 2002. After that the number of seismic stations has increased gradually. In 2010 the permanent seismic network consists of 15 seismic stations and 20 triaxial sensors. The purpose of the microearthquake measurements at Olkiluoto is to improve understanding of the structure, behaviour and long term stability of the bedrock. The investigation area includes two target areas. The larger target area, called seismic semiregional area, covers the Olkiluoto Island and its surroundings. The purpose is to monitor explosions and tectonic earthquakes in regional scale inside that area. The smaller target area is called the seismic ONKALO block, which is a 2 km *2 km *2 km cube surrounding the ONKALO. It is assumed that all the expected excavation induced events occur within this volume. At the moment the seismic ONKALO block includes ten seismic stations. An additional task of monitoring is related to safeguarding of the ONKALO. This report gives the results of microseismic monitoring during 2010.

  15. Results of Monitoring at Olkiluoto in 2010. Rock Mechanics

    International Nuclear Information System (INIS)

    Lahti, M.; Siren, T.

    2011-12-01

    The rock mechanical monitoring at Olkiluoto concentrates on the assessment of potential tectonic movements and stability of the bedrock. The construction of ONKALO is not expected to induce large-scale movements of the rock blocks or affect the rate of isostatic uplift but the evaluation of any tectonic events is important for the safety assessment. The monitoring consists of seismic measurements, GPS measurements and precise levelling campaigns at Olkiluoto and vicinity and extensometer and convergence measurements carried out in ONKALO. Posiva established a local seismic network of six stations on the island of Olkiluoto in 2002. After that the number of seismic stations has increased gradually. In 2010 the permanent seismic network consists of 15 seismic stations and 20 triaxial sensors. The purpose of the microearthquake measurements at Olkiluoto is to improve understanding of the structure, behaviour and long term stability of the bedrock. The investigation area includes two target areas. The larger target area, called seismic semiregional area, covers the Olkiluoto Island and its surroundings. The purpose is to monitor explosions and tectonic earthquakes in regional scale inside that area. The smaller target area is called the seismic ONKALO block, which is a 2 km *2 km *2 km cube surrounding the ONKALO. It is assumed that all the expected excavation induced events occur within this volume. At the moment the seismic ONKALO block includes ten seismic stations. An additional task of monitoring is related to safeguarding of the ONKALO. This report gives the results of microseismic monitoring during 2010

  16. Establishment of Karadeniz Technical University Permanent GNSS Station as Reactivated of TRAB IGS Station

    Directory of Open Access Journals (Sweden)

    Kazancı Selma Zengin

    2017-12-01

    Full Text Available In recent years, Global Navigation Satellite Systems (GNSS have gained great importance in terms of the benefi ts it provides such as precise geodetic point positioning, determining crustal deformations, navigation, vehicle monitoring systems and meteorological applications etc. As in Turkey, for this purpose, each country has set up its own GNSS station networks like Turkish National Permanent RTK Network analyzed precise station coordinates and velocities together with the International GNSS Service, Turkish National Fundamental GPS Network and Turkish National Permanent GNSS Network (TNPGN stations not only are utilized as precise positioning but also GNSS meteorology studies so total number of stations are increased. This work is related to the reactivated of the TRAB IGS station which was established in Karadeniz Technical University, Department of Geomatics Engineering. Within the COST ES1206 Action (GNSS4SWEC KTU analysis center was established and Trop-NET system developed by Geodetic Observatory Pecny (GOP, RIGTC in order to troposphere monitoring. The project titled “Using Regional GNSS Networks to Strengthen Severe Weather Prediction” was accepted to the scientifi c and technological research council of Turkey (TUBITAK. With this project, we will design 2 new constructed GNSS reference station network. Using observation data of network, we will compare water vapor distribution derived by GNSS Meteorology and GNSS Tomography. At this time, KTU AC was accepted as E-GVAP Analysis Centre in December 2016. KTU reference station is aimed to be a member of the EUREF network with these studies.

  17. Establishment of Karadeniz Technical University Permanent GNSS Station as Reactivated of TRAB IGS Station

    Science.gov (United States)

    Kazancı, Selma Zengin; Kayıkçı, Emine Tanır

    2017-12-01

    In recent years, Global Navigation Satellite Systems (GNSS) have gained great importance in terms of the benefi ts it provides such as precise geodetic point positioning, determining crustal deformations, navigation, vehicle monitoring systems and meteorological applications etc. As in Turkey, for this purpose, each country has set up its own GNSS station networks like Turkish National Permanent RTK Network analyzed precise station coordinates and velocities together with the International GNSS Service, Turkish National Fundamental GPS Network and Turkish National Permanent GNSS Network (TNPGN) stations not only are utilized as precise positioning but also GNSS meteorology studies so total number of stations are increased. This work is related to the reactivated of the TRAB IGS station which was established in Karadeniz Technical University, Department of Geomatics Engineering. Within the COST ES1206 Action (GNSS4SWEC) KTU analysis center was established and Trop-NET system developed by Geodetic Observatory Pecny (GOP, RIGTC) in order to troposphere monitoring. The project titled "Using Regional GNSS Networks to Strengthen Severe Weather Prediction" was accepted to the scientifi c and technological research council of Turkey (TUBITAK). With this project, we will design 2 new constructed GNSS reference station network. Using observation data of network, we will compare water vapor distribution derived by GNSS Meteorology and GNSS Tomography. At this time, KTU AC was accepted as E-GVAP Analysis Centre in December 2016. KTU reference station is aimed to be a member of the EUREF network with these studies.

  18. [STEM on Station Education

    Science.gov (United States)

    Lundebjerg, Kristen

    2016-01-01

    The STEM on Station team is part of Education which is part of the External Relations organization (ERO). ERO has traditional goals based around BHAG (Big Hairy Audacious Goal). The BHAG model is simplified to a saying: Everything we do stimulates actions by others to advance human space exploration. The STEM on Station education initiate is a project focused on bringing off the earth research and learning into classrooms. Educational resources such as lesson plans, activities to connect with the space station and STEM related contests are available and hosted by the STEM on Station team along with their partners such as Texas Instruments. These educational activities engage teachers and students in the current happenings aboard the international space station, inspiring the next generation of space explorers.

  19. Central Station Design Options

    DEFF Research Database (Denmark)

    2011-01-01

    . The work identifies the architecture, sizing and siting of prospective Central Stations in Denmark, which can be located at shopping centers, large car parking lots or gas stations. Central Stations are planned to be integrated in the Danish distribution grid. The Danish island of Bornholm, where a high...... overloading, more reference points might be necessary to represent various transformer loading levels. The subject of safety in Central Station is also addressed. A number of safety rules based on European standards apply to AC charging equipment up to 44 kW. The connection interlock and the automatic de......-energization are identified as fundamental requirements for safety in such a charging station. The connection interlock is a solution which ensures that no power is applied to the DC cable when the EV connector is not connected. The automatic de-energization device ensures that whenever a strain on the cable is detected, e...

  20. User Context Aware Base Station Power Flow Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  1. 2002 Status of coral reefs on the main volcanic islands of American Samoa: a resurvey of long term monitoring sites including benthic communities, fish communities, and key macroinvertebrates (NODC Accession 0001976)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This study demonstrates the important role that long term monitoring programs can play in understanding the natural variability and long term trends in the coral...

  2. Year 2000 status of coral reefs on the main volcanic islands of American Samoa: a resurvey of long term monitoring sites including benthic communities, fish communities, and key micro invertebrates (NODC Accession 0001976)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This study demonstrates the important role that long term monitoring programs can play in understanding the natural variability and long term trends in the coral...

  3. Community Radiation Monitoring Program

    International Nuclear Information System (INIS)

    Lucas, R.P. Jr.; Cooper, E.N.; McArthur, R.D.

    1990-05-01

    The Community Radiation Monitoring Program began its ninth year in the summer of 1989, continuing as an essential portion of the Environmental Protection Agency's long-standing off-site monitoring effort. It is a cooperative venture between the Department of Energy (DOE), the Environmental Protection Agency (EPA), the University of Utah (U of U), and the Desert Research Institute (DRI) of the University of Nevada System. The objectives of the program include enhancing and augmenting the collection of environmental radiation data at selected sites around the Nevada Test Site (NTS), increasing public awareness of that effort, and involving, in as many ways as possible, the residents of the off-site area in these and other areas related to testing nuclear weapons. This understanding and improved communication is fostered by hiring residents of the communities where the monitoring stations are located as program representatives, presenting public education forums in those and other communities, disseminating information on radiation monitoring and related subjects, and developing and maintaining contacts with local citizens and elected officials in the off-site areas. 8 refs., 4 figs., 4 tabs

  4. Water Quality Monitoring Manual.

    Science.gov (United States)

    Mason, Fred J.; Houdart, Joseph F.

    This manual is designed for students involved in environmental education programs dealing with water pollution problems. By establishing a network of Environmental Monitoring Stations within the educational system, four steps toward the prevention, control, and abatement of water pollution are proposed. (1) Train students to recognize, monitor,…

  5. Antarctic station life: The first 15 years of mixed expeditions to the Antarctic

    Science.gov (United States)

    Sarris, Aspa

    2017-02-01

    This study examined the experiences of women who lived and worked on remote and isolated Antarctic stations for up to 15 months at a time. The study employed purposeful sampling and a longitudinal - processual approach to study women's experiences over the first 15 years of mixed gender Antarctic expeditions. The retrospective analysis was based on a semi-structured interview administered to 14 women upon their return to Australia. The results showed that women referred to the natural physical Antarctic environment as one of the best aspects of their experience and the reason they would recommend the Antarctic to their friends as a good place to work. In describing the worst aspect of their experience, women referred to aspects of Antarctic station life, including: (i) the male dominated nature of station culture; (ii) the impact of interpersonal conflict, including gender based conflict and friction between scientists and trades workers; and (iii) the lack of anonymity associated with living and working with the same group of individuals, mainly men, for up to 12 months or more. The results are discussed within the context of the evolution of Antarctic station culture and recommendations are made in terms of the demography of expeditions, expeditioner selection and recruitment and the ongoing monitoring of Antarctic station culture. The study presents a framework that can be applied to groups and teams living and working in analogous isolated, confined and extreme work environments, including outer space missions.

  6. 46 CFR 131.350 - Station bill.

    Science.gov (United States)

    2010-10-01

    ... work of the member. The duties must include at least the following and should comprise any other duties... their immersion suits and lifejackets; and (ii) Directing them to their appointed stations. ...

  7. Space station operations management

    Science.gov (United States)

    Cannon, Kathleen V.

    1989-01-01

    Space Station Freedom operations management concepts must be responsive to the unique challenges presented by the permanently manned international laboratory. Space Station Freedom will be assembled over a three year period where the operational environment will change as significant capability plateaus are reached. First Element Launch, Man-Tended Capability, and Permanent Manned Capability, represent milestones in operational capability that is increasing toward mature operations capability. Operations management concepts are being developed to accomodate the varying operational capabilities during assembly, as well as the mature operational environment. This paper describes operations management concepts designed to accomodate the uniqueness of Space Station Freedoom, utilizing tools and processes that seek to control operations costs.

  8. Central station market development strategies for photovoltaics

    Science.gov (United States)

    1980-01-01

    Federal market development strategies designed to accelerate the market penetration of central station applications of photovoltaic energy system are analyzed. Since no specific goals were set for the commercialization of central station applications, strategic principles are explored which, when coupled with specific objectives for central stations, can produce a market development implementation plan. The study includes (1) background information on the National Photovoltaic Program, photovoltaic technology, and central stations; (2) a brief market assessment; (3) a discussion of the viewpoints of the electric utility industry with respect to solar energy; (4) a discussion of commercialization issues; and (5) strategy principles. It is recommended that a set of specific goals and objectives be defined for the photovoltaic central station program, and that these goals and objectives evolve into an implementation plan that identifies the appropriate federal role.

  9. Controversial power station

    International Nuclear Information System (INIS)

    Marcan, P.

    2008-01-01

    When information on plans to build a power station in Trebisov first appeared reactions differed. A 40-billion investment in a town with more than 20% unemployment seemed attractive. But some people did not like the idea of having a power plant located in the town. Around one year after the investment was officially announced TREND returned to Trebisov. In the meantime the investor has managed to overcome one of the biggest obstacles on its way to building a new power plant. The ministry responsible gave the environmental study a positive rating. But objectors are still not sure that everything is fine. They claim that the study misinterprets data and that the ministry did not show expertise when evaluating it. 'Is it possible that a coal power plant located in a town would have twice as many positive effects on peoples' health than negative ones? Why don't we build them everywhere?'asked the chairman of the civic society, Trebisov nahlas, Gejza Gore. The developer of the project, Ceskoslovenska energeticka spolocnost (CES), Kosice is fighting back and claims that their counterpart lacks professional arguments. In the meantime it is preparing for area management proceedings. Trebisov is also involved in the discussion and claims that the town planning scheme does not include such a project. The Ministry of Construction has a different opinion. In the opinion of the Ministry the town planning scheme allows a 885-megawatt power plant to be built only a few hundred meters away from housing estates. (author)

  10. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-01-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr 3 (Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  11. "Central Station" Londonis

    Index Scriptorium Estoniae

    2000-01-01

    Londoni galeriis Milch seitsme läti, leedu ja eesti kunstniku projekt "Central Station". Kuraatorid Lisa Panting, Sally Tallant. Eestist osalevad Hanno Soans (Catarina Campinoga koostöös valminud video), Kiwa, Kai Kaljo

  12. Materials Test Station

    Data.gov (United States)

    Federal Laboratory Consortium — When completed, the Materials Test Station at the Los Alamos Neutron Science Center will meet mission need. MTS will provide the only fast-reactor-like irradiation...

  13. Shippingport Station Decommissioning Project

    International Nuclear Information System (INIS)

    McKernan, M.L.

    1989-01-01

    The Shippingport Atomic Power Station was located on the Ohio River in Shippingport Borough (Beaver County), Pennsylvania, USA. The US Atomic Energy Commission (AEC) constructed the plant in the mid-1950s on a seven and half acre parcel of land leased from Duquesne Light Company (DLC). The purposes were to demonstrate and to develop Pressurized Water Recovery technology and to generate electricity. DLC operated the Shippingport plant under supervision of (the successor to AEC) the Department of Energy (DOE)-Naval Reactors (NR) until operations were terminated on October 1, 1982. NR concluded end-of-life testing and defueling in 1984 and transferred the Station's responsibility to DOE Richland Operations Office (RL), Surplus Facility Management Program Office (SFMPO5) on September 5, 1984. SFMPO subsequently established the Shippingport Station Decommissioning Project and selected General Electric (GE) as the Decommissioning Operations Contractor. This report is intended to provide an overview of the Shippingport Station Decommissioning Project

  14. Active Marine Station Metadata

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Active Marine Station Metadata is a daily metadata report for active marine bouy and C-MAN (Coastal Marine Automated Network) platforms from the National Data...

  15. Electrostatic pickup station

    CERN Multimedia

    CERN PhotoLab

    1982-01-01

    Electrostatic pickup station, with 4 interleaved electrodes, to measure beam position in the horizontal and vertical plane. This type is used in the transfer lines leaving the PS (TT2, TT70, TTL2). See also 7904075.

  16. Public Transit Stations

    Data.gov (United States)

    Department of Homeland Security — fixed rail transit stations within the Continental United States, Alaska, Hawaii, the District of Columbia, and Puerto Rico. The modes of transit that are serviced...

  17. Mukilteo Research Station

    Data.gov (United States)

    Federal Laboratory Consortium — Research at the Mukilteo Research Station focuses on understanding the life cycle of marine species and the impacts of ecosystem stressors on anadromous and marine...

  18. Maine Field Station

    Data.gov (United States)

    Federal Laboratory Consortium — In 2000 NOAA's National Marine Fisheries Service established the Maine Field Station in Orono, ME to have more direct involvement in the conservation of the living...

  19. FEMA DFIRM Station Start

    Data.gov (United States)

    Minnesota Department of Natural Resources — This table contains information about station starting locations. These locations indicate the reference point that was used as the origin for distance measurements...

  20. Natural Weathering Exposure Station

    Data.gov (United States)

    Federal Laboratory Consortium — The Corps of Engineers' Treat Island Natural Weathering Exposure Station is a long-term natural weathering facility used to study concrete durability. Located on the...

  1. Routes and Stations

    Data.gov (United States)

    Department of Homeland Security — he Routes_Stations table is composed of fixed rail transit systems within the Continental United States, Alaska, Hawaii, the District of Columbia, and Puerto Rico....

  2. USRCRN Station Information

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Documentation of United States Regional Climate Reference Network (USRCRN) installations in 2009. Installations documented are for USRCRN pilot project stations in...

  3. Gas Stations, US, 2010, NAVTEQ

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Gas_Stations dataset is derived from the Navteq 'AUTOSVC' SDC layer (FAC_TYPE=5540) and contains gas stations and petrol stations. This NAVTEQ dataset is...

  4. Enhanced Master Station History Report

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Enhanced Master Station History Report (EMSHR) is a compiled list of basic, historical information for every station in the station history database, beginning...

  5. Tobruk power station

    Energy Technology Data Exchange (ETDEWEB)

    Boergardts, B

    1978-01-01

    In February of 1975, the Electricity Corporation Benghazi (ECB) awarded a contract for the construction of a turnkey power station and seawater desalination plant in Tobruk, Libya to a consortium under the leadership of BBC Mannheim. This power station has an output of 129 MW and supplies about 24,000 m/sup 3/ of drinking water daily. It went into operation in 1977, two and a half years after the contract was awarded.

  6. Space Station galley design

    Science.gov (United States)

    Trabanino, Rudy; Murphy, George L.; Yakut, M. M.

    1986-01-01

    An Advanced Food Hardware System galley for the initial operating capability (IOC) Space Station is discussed. Space Station will employ food hardware items that have never been flown in space, such as a dishwasher, microwave oven, blender/mixer, bulk food and beverage dispensers, automated food inventory management, a trash compactor, and an advanced technology refrigerator/freezer. These new technologies and designs are described and the trades, design, development, and testing associated with each are summarized.

  7. Leadership at Antarctic Stations.

    Science.gov (United States)

    1987-03-01

    Claseification 6. No. Pegees LEADERSHIP AT ANTARTIC STATIONS hxIs i4 5, C =r~eta(C), 17 Rfs~W (R, Udusiied U)J 7. No Refs 8. Author(s) Edocumesnt I...whether there is a "best" approach to leadership at an Antartic Station and what leadership style may have the most to offer. 3~~ __ ___ Tipesis to be

  8. Data communications method for mobile network in fourth generation communications system, involves delivering decoded data to mobile station from relay station, where mobile station receives data from both relay and base stations

    DEFF Research Database (Denmark)

    2008-01-01

    The method involves utilizing a base station (BS) (100) to transmit data to a relay station (RS) (110) and a mobile station (MS) (120), where the data includes two messages. The BS is utilized to transmit the two messages by utilizing a linear combination method, and the data is received in the RS...

  9. Continuous environmental radiation monitoring network at Kalpakkam

    International Nuclear Information System (INIS)

    Somayaji, K.M.; Mathiyarasu, R.; Prakash, G.S.; Meenakshisundaram, V.; Rajagopal, V.

    1997-01-01

    The report highlights our experience in the design and installation of monitoring stations as part of continuous environmental radiation monitoring network around the periphery of the nuclear complex at Kalpakkam. Five monitoring stations, one each in south-west sector (Main Gate I) and south-south west (Main Gate II) and the others in North sector (HASL and ESG) and in north-west section (WIP) have been set up. Two independent detector systems, based on high pressure ionisation chamber (HPIC) and energy compensated GM have been installed at each of these locations and the data has been logged continuously using a data logger. The data so gathered at each monitoring station is retrieved every week by means of a hand held terminal (HHT) with a built-in non-volatile memory and transferred to an IBM PC-AT for data analysis and archival. The report discusses in depth the design and developmental efforts undertaken to set up the network, starting from the basic detectors. The work involved the design of suitable electrometer circuits for measuring the low levels of current from HPICs, and the subsequent study of the performance of the highly sensitive preamplifier under diurnal variations of ambient conditions. The report includes, in detail the design aspects and fabrication details of low current measuring electrometer circuits

  10. Surry Power Station, Units 1 and 2. Semiannual operating report, July--December 1974

    International Nuclear Information System (INIS)

    1974-01-01

    Net electric power generated by Surry Unit 1 was 6,930,353 MWH with the generator on line for 10,417.7 hours. Net electric power generated by Unit 2 was 5,699,299 MWH with the generator on line for 8,384.2 hours. Information is presented concerning operation, radioactive effluent releases, solid radioactive wastes, fuel shipments, occurrences in which temperature limitations on the condenser cooling water discharge were exceeded, changes in station organization, occupational personnel radiation exposure, nonradiological monitoring including thermal, physical, and biological programs, and the radiological environmental monitoring program. (U.S.)

  11. The Community Environmental Monitoring Program in the 21st Century: The Evolution of a Monitoring Network

    International Nuclear Information System (INIS)

    Hartwell, W.T.; Tappen, J.; Karr, L.

    2007-01-01

    This paper focuses on the evolution of the various operational aspects of the Community Environmental Monitoring Program (CEMP) network following the transfer of program administration from the U.S. Environmental Protection Agency (EPA) to the Desert Research Institute (DRI) of the Nevada System of Higher Education in 1999-2000. The CEMP consists of a network of 29 fixed radiation and weather monitoring stations located in Nevada, Utah, and California. Its mission is to involve stakeholders directly in monitoring for airborne radiological releases to the off site environment as a result of past or ongoing activities on the Nevada Test Site (NTS) and to make data as transparent and accessible to the general public as feasible. At its inception in 1981, the CEMP was a cooperative project of the U.S. Department of Energy (DOE), DRI, and EPA. In 1999-2000, technical administration of the CEMP transitioned from EPA to DRI. Concurrent with and subsequent to this transition, station and program operations underwent significant enhancements that furthered the mission of the program. These enhancements included the addition of a full suite of meteorological instrumentation, state-of-the-art electronic data collectors, on-site displays, and communications hardware. A public website was developed. Finally, the DRI developed a mobile monitoring station that can be operated entirely on solar power in conjunction with a deep-cell battery, and includes all meteorological sensors and a pressurized ion chamber for detecting background gamma radiation. Final station configurations have resulted in the creation of a platform that is well suited for use as an in-field multi-environment test-bed for prototype environmental sensors and in interfacing with other scientific and educational programs. Recent and near-future collaborators have included federal, state, and local agencies in both the government and private sectors. The CEMP also serves as a model for other programs wishing to

  12. Pickering Nuclear site wide groundwater monitoring system

    International Nuclear Information System (INIS)

    DeWilde, J.; Chin-Cheong, D.; Lledo, C.; Wootton, R.; Belanger, D.; Hansen, K.

    2001-01-01

    Ontario Power Generation Inc. (OPG) is continuing its efforts to understand the chemical and physical characteristics of the groundwater flow systems beneath the Pickering Nuclear Generating Station (PNGS). To this end, OPG constructed a site-wide Groundwater Monitoring System (GMS) at the PNGS to provide support to other ongoing environmental investigations and to provide a means to monitor current and future groundwater environmental issues. This paper will present the results of this work, including the development of a state-of-the-art data management system for storage and retrieval of environmental data for the site, which has applications for other power generation facilities. (author)

  13. Environmental radiation monitoring technology: Capabilities and needs

    International Nuclear Information System (INIS)

    Hofstetter, K.J.

    1994-01-01

    Radiation monitoring in the Savannah River Site (SRS) environment is conducted by a combination of automated, remote sampling and/or analysis systems, and manual sampling operations. This program provides early detection of radionuclide releases, minimizes the consequences, and assesses the impact on the public. Instrumentation installed at the release points monitor the atmospheric and aqueous releases from SRS operations. Ground water and air monitoring stations are strategically located throughout the site for radionuclide migration studies. The environmental radiological monitoring program at SRS includes: fixed monitoring stations for atmospheric radionuclide concentrations, aqueous monitors for surface water measurements, mobile laboratory operations for real-time, in-field measurements, aerial scanning for wide area contamination surveillance, and hand-held instruments for radionuclide-specific measurements. Rigorous environmentnal sampling surveillance coupled with laboratory analyses provide confirmatory results for all in-field measurements. Gaps in the technologies and development projects at SRS to fill these deficiencies are discussed in the context of customer needs and regulatory requirements

  14. Space Station tethered elevator system

    Science.gov (United States)

    Haddock, Michael H.; Anderson, Loren A.; Hosterman, K.; Decresie, E.; Miranda, P.; Hamilton, R.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The tethered elevator is an unmanned, mobile structure which operates on a ten-kilometer tether spanning the distance between Space Station Freedom and a platform. Its capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The report discusses the potential uses, parameters, and evolution of the spacecraft design. Emphasis is placed on the elevator's structural configuration and three major subsystem designs. First, the design of elevator robotics used to aid in elevator operations and tethered experimentation is presented. Second, the design of drive mechanisms used to propel the vehicle is discussed. Third, the design of an onboard self-sufficient power generation and transmission system is addressed.

  15. Camelias: a tool for the management of a complex set of γ spectrometry stations for the on-line monitoring of a reactor severe accident simulation in the framework of the Phebus FP programme

    International Nuclear Information System (INIS)

    Pantera, L.; Cornu, B.

    2003-01-01

    During a PHEBUS PF experiment, the on-line fission product release measurement is carried out by a set of seven γ stations supervised by a computer network. These stations generate about 20000 spectra for each experiment. These spectra are obtained under complex experimental conditions (high count rate, constrained nuclear environment and large diversity of configuration). The objective is to perform a quantitative γ-spectrometry analysis. The possibly complex use of self-attenuation models as well as the large volume of data to be treated led its to consider a flexible and generic method to manage the whole set of stations. The γ station calibration is carried out on-site. For each case, the developed methodology strictly uses the same approach for collecting data during the calibration phase, for calculations and for the software environment: that is the CAMELIAS application. The on-site calibration methodology is based on the use of a linear reference source allowing to reduce the 3D calculations to 2D calculations to obtain the reference efficiency function and the collimation function. Additional calculations then allow computing the efficiency function associated with the actual source. To centralize and to guarantee the coherence of the large volume of data collected during the calibration phase, we use a relational database management system. The computation of the self-attenuation coefficients associated with the actual source is performed by considering a simple model of self-attenuation along a straight line. The method, which can be generalized, is further applied to the delayed analysis of samplings and experimental devices of all the programs managed by the laboratory. (authors)

  16. The Need and Opportunity for an Integrated Research, Development and Testing Station in the Alaskan High Arctic

    Science.gov (United States)

    Hardesty, J. O.; Ivey, M.; Helsel, F.; Dexheimer, D.; Cahill, C. F.; Bendure, A.; Lucero, D. A.; Roesler, E. L.

    2016-12-01

    This presentation will make the case for development of a permanent integrated research and testing station at Oliktok Point, Alaska; taking advantage of existing assets and infrastructure, controlled airspace, an active UAS program and local partnerships. Arctic research stations provide critical monitoring and research on climate change for conditions and trends in the Arctic. The US Chair of the Arctic Council has increased awareness of gaps in our understanding of Artic systems, scarce monitoring, lack of infrastructure and readiness for emergency response. Less sea ice brings competition for commercial shipping and resource extraction. Search and rescue, pollution mitigation and safe navigation need real-time, wide-area monitoring to respond to events. Multi-national responses for international traffic will drive a greater security presence to protect citizens and sovereign interests. To address research and technology gaps, there is a national need for a High Arctic Station with an approach that partners stakeholders from science, safety and security to develop comprehensive solutions. The Station should offer year-round use, logistic support and access to varied ecological settings; phased adaptation to changing needs; and support testing of technologies such as multiple autonomous platforms, renewable energies and microgrids, and sensors in Arctic settings. We propose an Arctic Station at Oliktok Point, Alaska. Combined with the Toolik Field Station and Barrow Environmental Observatory, they form a US network of Arctic Stations. An Oliktok Point Station can provide complementary and unique assets that include: ocean access, and coastal and terrestrial systems; road access; controlled airspaces on land and ocean; nearby air facilities, medical and logistic support; atmospheric observations from an adjacent ARM facility; connections to Barrow and Toolik; fiber-optic communications; University of Alaska Fairbanks UAS Test Facility partnership; and an airstrip

  17. MHD power station with coal gasification

    International Nuclear Information System (INIS)

    Brzozowski, W.S.; Dul, J.; Pudlik, W.

    1976-01-01

    A description is given of the proposed operating method of a MHD-power station including a complete coal gasification into lean gas with a simultaneous partial gas production for the use of outside consumers. A comparison with coal gasification methods actually being used and full capabilities of power stations heated with coal-derived gas shows distinct advantages resulting from applying the method of coal gasification with waste heat from MHD generators working within the boundaries of the thermal-electric power station. (author)

  18. UMTS Network Stations

    Science.gov (United States)

    Hernandez, C.

    2010-09-01

    The weakness of small island electrical grids implies a handicap for the electrical generation with renewable energy sources. With the intention of maximizing the installation of photovoltaic generators in the Canary Islands, arises the need to develop a solar forecasting system that allows knowing in advance the amount of PV generated electricity that will be going into the grid, from the installed PV power plants installed in the island. The forecasting tools need to get feedback from real weather data in "real time" from remote weather stations. Nevertheless, the transference of this data to the calculation computer servers is very complicated with the old point to point telecommunication systems that, neither allow the transfer of data from several remote weather stations simultaneously nor high frequency of sampling of weather parameters due to slowness of the connection. This one project has developed a telecommunications infrastructure that allows sensorizadas remote stations, to send data of its sensors, once every minute and simultaneously, to the calculation server running the solar forecasting numerical models. For it, the Canary Islands Institute of Technology has added a sophisticated communications network to its 30 weather stations measuring irradiation at strategic sites, areas with high penetration of photovoltaic generation or that have potential to host in the future photovoltaic power plants connected to the grid. In each one of the stations, irradiance and temperature measurement instruments have been installed, over inclined silicon cell, global radiation on horizontal surface and room temperature. Mobile telephone devices have been installed and programmed in each one of the weather stations, which allow the transfer of their data taking advantage of the UMTS service offered by the local telephone operator. Every minute the computer server running the numerical weather forecasting models receives data inputs from 120 instruments distributed

  19. Seismic Calibration of Group 1 IMS Stations in Eastern Asia for Improved IDC Event Location

    National Research Council Canada - National Science Library

    Murphy, J. R; Rodi, W. L; Johnson, M; Sultanov, J. D; Bennett, T. J; Toksoz, M. N; Ovtchinnikov, V; Barker, B. W; Rosca, A. M; Shchukin, Y

    2006-01-01

    .... In order to establish a robust nuclear test monitoring capability, it is necessary to calibrate the IMS seismic stations used in monitoring, to account for systematic deviations from the nominal travel time curves...

  20. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)