WorldWideScience

Sample records for monitoring programme lamp

  1. Monitoring programme

    International Nuclear Information System (INIS)

    1994-06-01

    Her Majesty's Inspectorate of Pollution's 1992 report on its programme of monitoring radioactive substances is presented. Site operators' returns are verified and the report provides independent data on the environmental impact of authorized disposal of radioactive wastes. Radiation doses which may have been received by members of the public, fall well below the International Commission for Radiological Protection's (ICRP) recommended annual doses. (UK)

  2. Integrity Monitoring of Mercury Discharge Lamps

    Science.gov (United States)

    Tjoelker, Robert L.

    2010-01-01

    Mercury discharge lamps are critical in many trapped ion frequency standard applications. An integrity monitoring system can be implemented using end-of-life signatures observed in operational mercury discharge lamps, making it possible to forecast imminent failure and to take action to mitigate the consequences (such as switching to a redundant system). Mercury lamps are used as a source of 194-nm ultraviolet radiation for optical pumping and state selection of mercury trapped ion frequency standards. Lamps are typically fabricated using 202Hg distilled into high-purity quartz, or other 194-nm transmitting material (e.g., sapphire). A buffer gas is also placed into the bulb, typically a noble gas such as argon, neon, or krypton. The bulbs are driven by strong RF fields oscillating at .200 MHz. The lamp output may age over time by two internal mechanisms: (1) the darkening of the bulb that attenuates light transmission and (2) the loss of mercury due to migration or chemical interactions with the bulb surface. During fabrication, excess mercury is placed into a bulb, so that the loss rate is compensated with new mercury emanating from a cool tip or adjacent reservoir. The light output is nearly constant or varies slightly at a constant rate for many months/years until the mercury source is depleted. At this point, the vapor pressure abruptly falls and the total light output and atomic clock SNR (signal-to-noise ratio) decrease. After several days to weeks, the light levels decrease to a point where the atomic clock SNR is no longer sufficient to stay in lock, or the lamp self-extinguishes. This signature has been observed in four separate end-of-life lamp failures while operating in the Deep Space Network (DSN). A simple integrator circuit can observe and document steady-state lamp behavior. When the light levels drop over a predetermined time interval by a specified amount (e.g., 20 percent), an alarm is set. For critical operational applications, such as the DSN

  3. Harmonics Monitoring Survey on LED Lamps

    Directory of Open Access Journals (Sweden)

    Abdelrahman Ahmed Akila

    2017-03-01

    Full Text Available Light Emitting Diode (LED lamps are being increasingly used in many applications. These LED lamps operate using a driver, which is a switching device. Hence, LED lamps will be a source of harmonics in the power system. These harmonics if not well treated, may cause severe performance and operational problems. In this paper, harmonics (amplitude and phase angles generated by both LED lamps and conventional fluorescent lamps will be studied practically. Then they will be analyzed and evaluated. Compared to each other harmonics generated by both LED and conventional florescent lamps, self mitigation may occur based on the phase angle of these harmonics. All data will be measured using power analyzer and will be done on a sample of actual lamps.

  4. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  5. Environmental monitoring programme

    International Nuclear Information System (INIS)

    1991-08-01

    During 1989 there were about 1000 premises in England and Wales authorised to discharge radioactive wastes. The majority of these premises consisted of hospitals, universities and industrial, research or manufacturing centres. Discharges from these premises when made in accordance with the strict conditions specified in their authorisations will have been of little radiological significance. In the case of nuclear sites authorisations or approvals are issued jointly by the DoE and the Ministry of Agriculture, Fisheries and Food (MAFF) known collectively as the Authorising Departments. In Wales these functions are undertaken by the Welsh Office with the support of HMIP and MAFF. The Authorising Departments specify numerical limits on the amounts of radioactivity which operators may discharge to the environment. In addition operators are required to demonstrate that the best practicable means (BPM) to minimise discharges is undertaken. Operators are also required to carry out appropriate environmental monitoring to demonstrate the effectiveness of BPM. As part of their regulatory functions the Authorising Departments undertake their own environmental monitoring programmes to act as both a check on site operator's returns and to provide independent data on the exposure of the public. HM Inspectorate of Pollution has monitored levels of radioactivity in drinking water sources for many years and published results annually. MAFF undertakes two programmes to monitor radioactivity in the aquatic environment and in terrestrial foodstuffs and publishes annual reports. Environmental monitoring programmes undertaken by both nuclear site operators and government departments are summarised. (author)

  6. Compact fluorescent lamp phosphors in accidental radiation monitoring

    International Nuclear Information System (INIS)

    Murthy, K. V. R.; Pallavi, S. P.; Ghildiyal, R.; Parmar, M. C.; Patel, Y. S.; Ravi Kumar, V.; Sai Prasad, A. S.; Natarajan, V.; Page, A. G.

    2006-01-01

    The application of lamp phosphors for accidental dosimetry is a new concept. Since the materials used in fluorescent lamps are good photo luminescent materials, if one can either use the inherent defects present in the phosphor or add suitable modifiers to induce thermoluminescence (TL) in these phosphors, then the device (fluorescent lamp) can be used as an accidental dosemeter. In continuation of our search for a suitable phosphor material, which can serve both as an efficient lamp phosphor and as a good radiation monitoring device, detailed examination has been carried out on cerium and terbium-doped lanthanum phosphate material. A 90 Sr beta source with 50 mCi strength (1.85 GBq) was used as the irradiation source for TL studies. The TL response as a function of dose received was examined for all phosphors used and it was observed that the intensity of the TL peak vs. dose received was a linear function in the dose range 0.1-200 Gy in each case. Incidentally LaPO 4 :Ce,Tb is a component of the compact fluorescent lamp marketed recently as an energy bright light source. Besides having very good luminescence efficiency, good dosimetric properties of these phosphors render them useful for their use in accidental dosimetry also. (authors)

  7. Environmental monitoring programme

    International Nuclear Information System (INIS)

    Schroeder, H.J.

    1981-01-01

    The tasks of the radiation protection department at a nuclear power plant are mentioned and described. Special attention is given to the environmental monitoring program. The consequences from regulations, the different items in the program and the results are described. (orig./RW)

  8. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  9. The Danish Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.; Manscher, O. H.

    The Danish Air Quality Monitoring Programme (LMP) was started in 1982 as the first nation-wide urban air pollution monitoring programme in Denmark. The programme has been adjusted to the pollution pattern by two revisions. The present phase (LMP III) was started in 1992. This report presents...... Copenhagen the same program is con-ducted as at the street stations with the inclusion of O3. Only NO, NO2 and O3 are reported from the other rural site. Air quality limit values have been implemented in Den-mark for NO2, SO2, TSP in order to protect human health. All limit values are based on EU limit...

  10. Monitoring and Morphologic Classification of Pediatric Cataract Using Slit-Lamp-Adapted Photography.

    Science.gov (United States)

    Long, Erping; Lin, Zhuoling; Chen, Jingjing; Liu, Zhenzhen; Cao, Qianzhong; Lin, Haotian; Chen, Weirong; Liu, Yizhi

    2017-11-01

    To investigate the feasibility of pediatric cataract monitoring and morphologic classification using slit lamp-adapted anterior segmental photography in a large cohort that included uncooperative children. Patients registered in the Childhood Cataract Program of the Chinese Ministry of Health were prospectively selected. Eligible patients underwent slit-lamp adapted anterior segmental photography to record and monitor the morphology of their cataractous lenses. A set of assistance techniques for slit lamp-adapted photography was developed to instruct the parents of uncooperative children how to help maintain the child's head position and keep the eyes open after sleep aid administration. Briefly, slit lamp-adapted photography was completed for all 438 children, including 260 (59.4%) uncooperative children with our assistance techniques. All 746 images of 438 patients successfully confirmed the diagnoses and classifications. Considering the lesion location, pediatric cataract morphologies could be objectively classified into the seven following types: total; nuclear; polar, including two subtypes (anterior and posterior); lamellar; nuclear combined with cortical, including three subtypes (coral-like, dust-like, and blue-dot); cortical; and Y suture. The top three types of unilateral cataracts were polar (55, 42.3%), total (42, 32.3%), and nuclear (23, 17.7%); and the top three types of bilateral cataracts were nuclear (110, 35.8%), total (102, 33.2%), and lamellar (34, 11.1%). Slit lamp-adapted anterior segmental photography is applicable for monitoring and classifying the morphologies of pediatric cataracts and is even safe and feasible for uncooperative children with assistance techniques and sleep aid administration. This study proposes a novel strategy for the preoperative evaluation and evidence-based management of pediatric ophthalmology (Clinical Trials.gov, NCT02748031).

  11. Monitoring programmes for internal exposure: designing criteria

    International Nuclear Information System (INIS)

    Rojo, Ana M.; Gomez Parada, Ines.

    2007-01-01

    The purpose of this document is to offer guidance for the decision whether a monitoring programme is required and how it should be designed. It can be also used as a tool for making the standing programmes consistent with the most recent publications on internal dosimetry, such as ISO 20553 'Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material', specific publications of the IAEA and ICRP, and including the conclusions of the OMINEX Project ('Optimisation of Monitoring for Internal Exposures') and IDEAS Project. It is established that the general purpose of the monitoring is verify that each worker is protected adequately against risks from radionuclide intakes and document that the protection complies with legal requirements. The criteria for a particular monitoring programme designing is based on the magnitude of the probable intake and the possibility of detecting a significant event when it occurs. So, the risk assessment for each work process must be evaluated and each worker is classified accordingly. This classification implies the acceptance of reference effective dose values (1 y 6 mSv/y ). (author) [es

  12. The Vaalputs radiological environmental monitoring programme

    International Nuclear Information System (INIS)

    Van As, D.; Posnik, S.J.; Bain, C.A.R.

    1986-01-01

    An environmental monitoring programme was initiated two years before radioactive waste was due to be disposed of at the Vaalputs site. During this time a database was established against which future changes in the radiation levels of the environment could be measured. The monitoring network included the measurement of radiation doses, radioactivity levels in soil, vegetation, groundwater, and agricultural produce. A natural radiation dose to the average individual of 2,2 mSv per annum was established. Meteorological parameters were collected and used to assess the potential release and transport of radioactivity through the environment. A survey of the habits of the surrounding population was conducted to identify the principal food chains. In addition to complying with the licensing requirements for the waste disposal site, the environmental monitoring programme is contributing valuable scientific information on evapotranspiration and percolation in semi-arid environments

  13. The Danish Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP) was started in 1982 as the first nation-wide urban air pollution monitoring programme in Denmark. The programme has been adjusted to the pollution pattern by two revisions. The present phase (LMP III) was started in 1992. From 2000 a new phase...... continuously in order to improve the knowledge about the NO, NO2 and O3 problem complex. At the rural site outside Copenhagen the same program is conducted as at the street stations with the inclusion of O3. Only NO, NO2 and O3 are reported from the other rural site. Air quality limit values have been...... and plants. The new EU Directives introduce revised standards for NO2, SO2, particles (PM10) and Pb. They are implemented through the first "daughter" Directive to the Air Quality Framework Directive. It was adopted by the EU council in April 1999. The new limit values shall be in force from January 2001 (18...

  14. Proposed indicators for a monitoring programme. Summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    The report presents proposals for a set of indicators to be used in a coordinated monitoring programme for the North Sea and Skagerrak ecosystems. This report suggests reference values and action thresholds for the indicators and suitable monitoring stations and survey transects, based on existing time series where possible. The relevance of the proposed indicators is also assessed to national and international environmental policy goals. The national targets of Norway's environmental policy and indicators used in the monitoring systems for the other Norwegian open sea areas were taken into account when drawing up the proposals. In the international context, The management plan was also assessed to the Convention on Biological Diversity, the International Council for the Exploration of the Sea (ICES), the Convention for the Protection of the Marine Environment of the North-East Atlantic (the OSPAR Convention) and the EU's Marine Strategy Framework Directive (MSFD).(Author)

  15. Proposed indicators for a monitoring programme. Summary

    International Nuclear Information System (INIS)

    2012-01-01

    The report presents proposals for a set of indicators to be used in a coordinated monitoring programme for the North Sea and Skagerrak ecosystems. This report suggests reference values and action thresholds for the indicators and suitable monitoring stations and survey transects, based on existing time series where possible. The relevance of the proposed indicators is also assessed to national and international environmental policy goals. The national targets of Norway's environmental policy and indicators used in the monitoring systems for the other Norwegian open sea areas were taken into account when drawing up the proposals. In the international context, The management plan was also assessed to the Convention on Biological Diversity, the International Council for the Exploration of the Sea (ICES), the Convention for the Protection of the Marine Environment of the North-East Atlantic (the OSPAR Convention) and the EU's Marine Strategy Framework Directive (MSFD).(Author)

  16. Monitoring programme. Radioactive substances report for 1994

    International Nuclear Information System (INIS)

    1995-09-01

    In the United Kingdom, Her Majesty's Inspectorate of Pollution commissions independent monitoring of radioactive discharges to the environment. This report presents the results of such monitoring for 1994. It covers nuclear sites, two non-nuclear sites which use large amounts of tritium and several landfill sites which receive low-level radioactive waste for controlled burial. The monitoring programme concentrates on activity levels in environmental materials that might result in exposure of the public to radiation from non-food pathways. The results show that exposures from these pathways in 1994 remain similar to those in previous years and in all cases are estimated to have been substantially lower than the International Commission on Radiological Protection's recommended dose limit of 1mSv per year. (6 figures; 20 tables; 29 references) (UK)

  17. A Water Quality Monitoring Programme for Schools and Communities

    Science.gov (United States)

    Spellerberg, Ian; Ward, Jonet; Smith, Fiona

    2004-01-01

    A water quality monitoring programme for schools is described. The purpose of the programme is to introduce school children to the concept of reporting on the "state of the environment" by raising the awareness of water quality issues and providing skills to monitor water quality. The programme is assessed and its relevance in the…

  18. Radioactive substances monitoring programme. Report for 1995

    International Nuclear Information System (INIS)

    1995-01-01

    The Radioactive Substances Act 1993 provides for controls to be exercised over the use and keeping of radioactive materials and the accumulation and disposal of radioactive wastes. The Environment Agency (the Agency) has been responsible for administration and enforcement of the Act in England and Wales since its formation on 1 April 1996. Prior to this date the work was undertaken by Her Majesty's Inspectorate of Pollution (HMIP). In support of its regulatory functions HMIP commissioned independent monitoring. This report presents the results from monitoring undertaken in 1995. The 1995 HMIP programme required operators of certain sites to provide samples of their liquid effluents for independent radiochemical analysis. The results provide checks on site operators' returns and insights into their quality assurance (QA) procedures and analytical techniques. The analyses were undertaken by the Laboratory of the Government Chemist (LGC) at its laboratories in Teddington, Middlesex. The programme also included checks on solid low level radioactive waste destined for land disposal at the site operated by British Nuclear Fuels plc (BNFL) at Drigg in Cumbria. (author)

  19. Monitoring programme. Radioactive substances - report for 1994

    International Nuclear Information System (INIS)

    1995-09-01

    The monitoring of radioactive substances in the vicinity of nuclear sites in the United Kingdom by Her Majesty's Inspectorate of Pollution, acts as an independent check on the operator's returns, on the environmental impact of radioactive waste disposal at authorised sites and on radiation doses to critical groups of the public. In 1994 the programme included the analysis of 160 effluent samples, the analysis of low-level solid radioactive waste destined for the British Nuclear Fuels site at Drigg, and the analysis of a total of 290 environmental samples and direct monitoring at over 150 locations. The materials monitored are those that might result in exposure of the public to radiation by non-food pathways and complements monitoring by the Ministry of Agriculture, Food and Fisheries. Radiation exposures by these pathways which may have been incurred in 1994 are similar to those in previous years and, in all cases, fall substantially below the International Commission on Radiological Protection's recommended principal dose limit of 1mSv per year. (UK)

  20. DANIDA; Air Quality Monitoring Programme. Mission 2 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1996-06-01

    The report deals with the EIMP (Environmental Information and Monitoring Programme for the Arab Republic of Egypt). The programme is funded by Danida which is a cooperation project between Norway and Denmark. The programme covers the monitoring of air pollution, coastal water monitoring, and the monitoring of pollution sources and emissions. This report pays the attention to the Norwegian part of the programme executed by NILU (Norwegian Institute for Air Research) which covers the development air quality monitoring network. 14 refs., 51 figs., 18 tabs.

  1. Survey of environment related monitoring programmes of international organizations and their contribution to international monitoring programmes

    International Nuclear Information System (INIS)

    1986-12-01

    The report is a summary of environment-related monitoring programmes of international governmental organizations and their contribution to international monitoring programmes. it presents the situation as of November 1986: This survey has been prepared by a consultant for the Secretariat as a background document for the second meeting of the Environment Experts, Economic Summit in Munich, November 1986. It serves information purposes only. No claim for completeness is intended. This report may also prove to be helpful for administrators and the scientific community as regards gaining knowledge on present arrangements, approaches and environmental activities in the framework of international organizations. In this light, the present report could facilitate communication and progress in solving pressing environmental problems on the international level. (orig.)

  2. Optimizing study design for multi-species avian monitoring programmes

    Science.gov (United States)

    Jamie S. Sanderlin; William M. Block; Joseph L. Ganey

    2014-01-01

    Many monitoring programmes are successful at monitoring common species, whereas rare species, which are often of highest conservation concern, may be detected infrequently. Study designs that increase the probability of detecting rare species at least once over the study period, while collecting adequate data on common species, strengthen programme ability to address...

  3. Marine fisheries monitoring programmes in South Africa

    Directory of Open Access Journals (Sweden)

    M. Mayekiso

    2010-01-01

    Full Text Available South Africa was an early leader in multidisciplinary studies of marine resources, particularly with the Benguela Ecology Programme in the 1980s and 1990s and catch records are available for some species dating back more than a century. Resources data have focused on trends in catches, fishing effort and changes in distribution and abundance of harvested resources, which often account for a major part of the structure and functioning of marine ecosystems. Data have been collected by means of fishery-dependent and fishery-independent survey techniques appropriate to each particular stock and analysed using traditional single species stock assessment techniques. The data are complemented by comprehensive information on the environment and top predators and have been analysed using trophodynamic models such as Ecopath with Ecosim. Future approaches include a shift to an ecosystem approach to fisheries monitoring and management, in an attempt to reconcile utilisation and biodiversity conservation objectives. Despite these scientific achievements, the single species approach to the management of most resources still persists, with only limited interactions between competing species or predators and prey being formally taken into account when modelling the stock dynamics and providing management advice to the authorities.

  4. Optimisation of internal contamination monitoring programme by integration of uncertainties

    International Nuclear Information System (INIS)

    Davesne, E.; Casanova, P.; Chojnacki, E.; Paquet, F.; Blanchardon, E.

    2011-01-01

    Potential internal contamination of workers is monitored by periodic bioassay measurements interpreted in terms of intake and committed effective dose by the use of biokinetic and dosimetric models. After a prospective evaluation of exposure at a workplace, a suitable monitoring programme can be defined by choosing adequate measurement techniques and frequency. In this study, the sensitivity of a programme is evaluated by the minimum intake and dose, which may be detected with a given level of confidence by taking into account uncertainties on exposure conditions and measurements. This is made for programme optimisation, which is performed by comparing the sensitivities of different alternative programmes. These methods were applied at the AREVA NC reprocessing plant and support the current monitoring programme as the best compromise between the cost of the measurements and the sensitivity of the programme. (authors)

  5. Terrestrial radioactivity monitoring programme (TRAMP) report for 1986

    International Nuclear Information System (INIS)

    1988-01-01

    The Ministry of Agriculture, Fisheries and Food (MAFF) undertakes a comprehensive independent monitoring programme for radioactivity in terrestrial foodstuffs in England and Wales, this report presents the results from the first full year of operation of this programme and complements the data published annually by the Ministry's Directorate of Fisheries Research in respect of the aquatic environment. This work is undertaken in Wales on behalf of the Secretary of State. The Terrestrial Radioactivity Monitoring Programme (TRAMP) concentrates on samples of agricultural produce (milk, crops, meat) collected from the vicinity of the major nuclear sites in England and Wales and is independent of monitoring undertaken for various purposes by site operators. (author)

  6. HMIP Monitoring Programme radioactive substances report for 1990

    International Nuclear Information System (INIS)

    1992-03-01

    The programme of environmental monitoring of radioactive substances in England and Wales during 1990, was completed satisfactorily under the auspices of Her Majesty's Inspectorate of Pollution. The programme concentrates on monitoring activity levels in environmental materials which might result in radiation exposure of the public from non-food pathways. The programme acts as a check on site operator's returns and provides independent data on the environmental impact of authorised disposals of radioactive wastes and on radiation doses to critical groups of the public. This report presents the data from this continuing monitoring programme. The monitoring was carried out at installations controlled by British Nuclear Fuels PLC, Nuclear Electric the United Kingdom Atomic Energy Authority, Amersham International PLC, the Ministry of Defence, at two non-nuclear sites which use tritium, the works of Capper Pass Ltd who carry out lead smelting and at several landfill sites where controlled buried of low-level radioactive wastes is carried out. (Author)

  7. A Peer Review of the RPII Environmental Monitoring Programme

    International Nuclear Information System (INIS)

    Mitchell, P.; Hunt, J.; Ledgerwood, K.; Nielsen, S.; O'Donnell, C

    2009-12-01

    The RPII has since the early 1980s carried out an environmental monitoring programme covering radioactivity in air, food and water. The primary focus of this programme has been the assessment of human exposure and the protection of human health. The programme aims to meet Irish and European Union legal requirements, other national and international commitments and to support the RPII's advisory and information provision functions. In 2009 the RPII had the scope and effectiveness of its monitoring programme reviewed by an international peer group. This report provides the background to the review; an overview of the documents provided to the peer group for conduction of the review; and the comments and recommendations by the peer group. The key objectives of the review was to consider whether the RPII environmental monitoring programme is meeting the stated aims and objectives and to provide recommendations for improvement if required. This exercise is part of a continual process of review and improvement of the RPII's monitoring programme. It addresses both continuous monitoring and project based elements of the programme. It was designed to be conducted at a strategic rather than an operational level

  8. Monitoring and evaluating astronomy outreach programmes: Challenges and solutions

    Directory of Open Access Journals (Sweden)

    Sarah Chapman

    2015-05-01

    Full Text Available A number of tools exist to guide the monitoring and evaluation of science, technology, engineering and mathematics (STEM education and outreach programmes. Fewer tools exist for evaluating astronomy outreach programmes. In this paper we try to overcome this limitation by presenting a monitoring and evaluation framework developed for the International Astronomical Union's Office of Astronomy for Development (OAD. The mandate of the OAD is to stimulate sustainable development at an international level and to expand astronomy education and outreach globally. The broad assumptions of this programme are that astronomy has the potential to contribute to human development by means of the transferable nature of its science discoveries, as well as its potential to activate feelings of wonderment, inspiration and awareness of the universe. As a result, the programme potentially embodies a far broader mix of outcomes than conventionally considered in STEM evaluation approaches. Towards this aim, we operationalise our monitoring and evaluation approach by first outlining programme theories for three key OAD programmes: a programme for universities and research, another one for schools, and one for public outreach. We then identify outcomes, indicators and measures for each one of these programmes. We conclude with suggestions for evaluating the global impact of astronomy for development.

  9. DANIDA; Air Quality Monitoring Programme. Mission 3 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.; Marsteen, L.

    1996-12-31

    In the development of the Environmental Information and Monitoring Programme for the Arab Republic of Egypt (EIMP), NILU is responsible for the establishment of an air pollution monitoring system. This report summarizes the third mission to Egypt and includes meetings and site visit reports. Air quality sites in Alexandria are described and comments are given to earlier selected sites in Cairo

  10. 1988 sheep monitoring programme January - December 1988

    International Nuclear Information System (INIS)

    Colgan, P.A.; Scully, B.J.

    1989-06-01

    This report summarises the work undertaken by the Board during 1988 and includes the results of in vivo farm measurements, slaughterhouse monitoring and butcher's shops surveys relating to sheep and sheepmeat

  11. 1989 sheep monitoring programme January - December 1989

    International Nuclear Information System (INIS)

    Colgan, P.A.; Scully, B.J.

    1990-06-01

    This report details the work undertaken by the Board during 1989 and includes the results of on-farm measurements, slaughterhouse monitoring and butchers' shops surveys relating to sheep and sheepmeat (author)

  12. Sheep monitoring programme January - September 1988

    International Nuclear Information System (INIS)

    Colgan, P.A.; Scully, B.J.

    1989-02-01

    This report summarises the work undertaken by the Board during the first nine months of 1988, and includes the results of in vivo farm measurements, slaughterhouse monitoring and butchers' shops surveys relating to sheep and sheepmeat.(author)

  13. Characteristics of the IAEA correlation monitor material for surveillance programmes

    International Nuclear Information System (INIS)

    Wallin, K.; Valo, M.; Rintamaa, R.; Toerroenen, K.

    1989-08-01

    Within the IAEA Coordinated Research Programme on optimizing of reactor pressure vessel surveillance programmes and their analysis, phase 3, a specially tailored 'radiation sensitive' correlation monitor material has been fabricated. This material will serve as a reference to the IAEA programme for future vessel surveillance programmes throughout the world. An extensive evaluation of the correlation monitor material in the as-received condition has been carried out in Finland and the results are presented here. The mechanical properties measured at different temperatures include Charpy V notch and instrumented precracked Charpy data, and elastic-plastic fracture toughness (J). The specimen size and geometry have been varied in the tests. Correlation between different fracture properties are evaluated and discussed

  14. HMIP monitoring programme: radioactive substances report for 1990

    International Nuclear Information System (INIS)

    1992-03-01

    Discharges of radioactive wastes to the environment can only be made under authorisation from government bodies. The main potential sources of environmental contamination in England are nuclear sites (power stations, fuel fabrication and reprocessing plants), some industrial premises such as metal smelters, and landfill sites. As well as the environmental monitoring programmes undertaken by the operators of such sites various government bodies also undertake monitoring. In January 1988 Her Majesty's Inspectorate of Pollution (HMIP) initiated a programme to monitor exposure of the public from non-food pathways such as could occur from occupation of beaches, river banks etc. Radiation levels and radiochemical and gamma spectra of samples collected at specified locations near nuclear sites and industrial premises have been monitored every quarter since then. The results for 1990 are presented and discussed. (UK)

  15. Programmes and Systems for Source and Environmental Radiation Monitoring

    International Nuclear Information System (INIS)

    2010-01-01

    The discharge of radionuclides to the atmosphere and aquatic environments is a legitimate practice in the nuclear and other industries, hospitals and research. Where appropriate, monitoring of the discharges and of relevant environmental media is an essential regulatory requirement in order to ensure appropriate radiation protection of the public. Such monitoring provides information on the actual amounts of radioactive material discharged and the radionuclide concentrations in the environment, and is needed to demonstrate compliance with authorized limits, to assess the radiation exposure of members of the public and to provide data to aid in the optimization of radiation protection. Uncontrolled releases of radionuclides to the atmosphere and aquatic environments may occur as a result of a nuclear or radiological accident. Again, monitoring at the source of the release and of the environment is necessary. In this case, monitoring is used both to assess the radiation exposure of members of the public and to determine the actions necessary for public protection, including longer term countermeasures. Source and environmental monitoring associated with the release of radionuclides to the environment is the subject of a number of IAEA Safety Standards, particularly IAEA Safety Standard RS-G-1.8 (Environmental and Source Monitoring for Purposes of Radiation Protection). This publication is intended to complement this Safety Guide and, by so doing, replaces Safety Series No. 41 (Objectives and Design of Environmental Monitoring Programmes for Radioactive Contaminants) and Safety Series No. 46 (Monitoring of Airborne and Liquid Radioactive Releases from Nuclear Facilities to the Environment). Like Safety Standard RS-G-1.8, this Safety Report deals with monitoring at the source and in the environment associated with authorized releases of radionuclides to the environment. It also deals with the general issues of emergency monitoring during and in the aftermath of an

  16. DANIDA; Air Quality Monitoring Programme. Mission 4 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1997-12-31

    In the development of the Environmental Information and Monitoring Programme for the Arab Republic of Egypt (EIMP), NILU is responsible for the establishment of an air pollution monitoring system. This report summarizes the fourth mission to Egypt, including planning of the second phase meetings and site visits. Additional air quality sites in Cairo have been described. A project group meeting and a visit to Egypt Meteorological Service have been reported

  17. Real-time monitoring of trace-level VOCs by an ultrasensitive compact lamp-based VUV photoionization mass spectrometer

    Science.gov (United States)

    Sun, W. Q.; Shu, J. N.; Zhang, P.; Li, Z.; Li, N. N.; Liang, M.; Yang, B.

    2015-06-01

    In this study, we report on the development of a compact lamp-based vacuum ultraviolet (VUV) photoionization mass spectrometer (PIMS; hereafter referred to as VUV-PIMS) in our laboratory; it is composed of a radio frequency-powered VUV lamp, a VUV photoionizer, an ion-immigration region, and a reflection time-of-flight mass spectrometer. By utilizing the novel photoionizer consisting of a photoionization cavity and a VUV light baffle, extremely low background noise was obtained. An ultrasensitive detection limit (2σ) of 3 pptv was achieved for benzene after an acquisition time of 10 s. To examine its potential for application in real-time sample monitoring, the developed VUV-PIMS was employed for the continuous measurement of urban air for six days in Beijing, China. Strong signals of trace-level volatile organic compounds such as benzene and its alkylated derivatives were observed in the mass spectra. These initial experimental results reveal that the instrument can be used for the online monitoring of trace-level species in the atmosphere.

  18. Circumpolar Biodiversity Monitoring Programme coastal biodiversity monitoring background paper

    Science.gov (United States)

    McLennan, Donald; Anderson, Rebecca D.; Wegeberg, S.; Pettersvik Arvnes, Maria; Sergienko, Liudmila; Behe, Carolina; Moss-Davies, Pitseolak; Fritz, S.; Markon, Carl J.; Christensen, T.; Barry, T.; Price, C.

    2016-01-01

    In 2014, the United States (U.S.) and Canada agreed to act as co-lead countries for the initial development of the Coastal Expert Monitoring Group (CEMG) as part of the Circumpolar Biodiversity Monitoring Program (CBMP, www. cbmp.is) under the Arctic Council’s Conservation of Arctic Flora and Fauna (CAFF, www.caff.is) working group. The CAFF Management Board approved Terms of Reference for the CEMG in the spring of 2014. The primary goal of the CEMG is to develop a long term, integrated, multi-disciplinary, circumpolar Arctic Coastal Biodiversity Monitoring Plan (the Coastal Plan) that relies on science and Traditional Knowledge, and has direct and relevant application for communities, industry, government decision makers, and other users. In addition to the monitoring plan, the CAFF working group has asked the CBMP, and thus the CEMG, to develop an implementation plan that identifies timeline, costs, organizational structure and partners. This background paper provides a platform for the guidance for the development of the Coastal Plan and is produced by the CEMG with assistance from a number of experts in multiple countries.

  19. CAP vessel monitoring. Programme, measurement and neutron calculation

    International Nuclear Information System (INIS)

    Farrugia, J.M.; Nimal, J.C.; Totth, B.; Lloret, R.; Perdreau, R.

    1982-03-01

    Starting with the design of the CAP (Prototype Advanced NSSS), a programme for pressure vessel monitoring has been prepared, including dosimetry. The dosimetry programme encompasses activation dosimeters (Cu, Nb, Co) and fission dosimeters ( 237 Np, 238 U) installed either inside the pressure vessel with the monitoring test-samples, or in a counting tube outside the pressure vessel. In the first place, a description of the method for neutronic calculation is given; such calculations use the codes ANISN and MERCURE 4 allowing assessment of the neutron spectrum seen by the detectors and the related reaction coefficient. This is followed by a description of the instrumentation. The initial dosimetry results available after the initial operating cycles concur with calculations [fr

  20. Programmable pulse and analog data logger for environmental monitoring

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.

    1983-01-01

    A programmable data logger with 16 analog channels and 8 pulse channels is described to which nuclear radiation detectors, meteorological measuring instruments and transducers were connected for registration of operating data in the course of a research project in which natural and man-made radionuclide concentrations were measured near the ground. The set-up can be modified for other measuring and monitoring tasks. (orig.) [de

  1. Radioactivity monitoring programme of Krsko nuclear power plant

    International Nuclear Information System (INIS)

    Miklavzic, U.; Martincic, R.; Kanduc, M.; Lulic, S.; Kovac, J.; Breznik, B.

    1996-01-01

    As a successor to the preoperational surveillance programme, the regular offsite radioactivity monitoring programme (RMP) of the Krsko Nuclear Power Plant (NPP) was implemented in 1982, when the power plant formally commenced operating. Observations collected during the first years of its operation were later also the basis for setting up the official 'Regulatory guide on monitoring of nuclear installations', issued not earlier than in 1986. The basic criterion which governed the selection of measuring methods, sampling techniques and locations, was the extent to which the data obtained could serve for the realistic assessment of the committed dose to a member of the population, and later on to members of a representative (critical) group. To be able to differentiate the radioactivity released through the liquid and gaseous effluents of the NPP from other radiation sources (natural radioactivity, global contamination), and especially because of the varying radiotoxicity of different radionuclides, in principle monitoring in the environment, as at the source, had to provide activity data for each individual radionuclide appearing in the effluents. Therefore, as early as 1982 the programme attributed the main weight to high resolution gamma spectrometry, combined with specific radiochemical analytical methods (e.g. 90 Sr/ 89 Sr, 3 H, 14 C, alpha spectrometry of Pu isotopes) which together made feasible determination of individual specific activities of the most significant man-made and natural radionuclides. By weighting the specific activities of the radionuclides identified and measured in the media surveyed by dose factors for intake, the quantity 'B' - the so-called 'radiological burden', was calculated and introduced in the yearly-summary tables. Expressed in relative units, from which the committed dose could be readily calculated, the burden B very lucidly disclosed the relative importance of different artificial pollutants and natural radioactivity present in

  2. Development of web based system for internal monitoring programme

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Vanessa R. de; Rodrigues Junior, Orlando; Todo, Alberto S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: vrlima@ipen.br; rodrijr@ipen.br; astodo@ipen.br

    2007-07-01

    The purposes of monitoring in general are to verify and to document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, it forms part of the overall radiation protection programme, which starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  3. Development of Web based system for individual internal monitoring programme

    International Nuclear Information System (INIS)

    Lima, Vanessa Rogeria de

    2007-01-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  4. Marker lamps

    International Nuclear Information System (INIS)

    Watkins, D.V.

    1980-01-01

    A marker lamp is described which consists of a block of transparent plastics material encapsulated in which is a radioactive light source. These lights comprise a small sealed glass capsule, the hollow inside surface of which is coated with phosphor and which contains tritium or similar radioactive gas. The use of such lamps for identification marking of routes, for example roads, and for identification of underwater oil pipelines is envisaged. (U.K.)

  5. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  6. Radiation monitoring programme in a university hot laboratory

    International Nuclear Information System (INIS)

    Tillander, M.; Heinonen, O.J.

    1979-01-01

    The Department of Radiochemistry in the University of Helsinki is the only institute teaching radiochemistry at the university level in Finland. The research programme of the Deparment must therefore include the uses of radiation and radionuclides in many branches of science. The students must receive adequate instruction in radiation protection for safe work in laboratories. This also has the educational benefit that the radiochemists will subsequently be able to observe the necessary safety precautions when employing ionizing radiation professionally. The Department of Radiochemistry consists of the following laboratories: a radiotracer laboratory, a neutron/electron and a gamma irradiation laboratory, an environmental low activity level laboratory, a whole-body counting laboratory, a reactor chemistry laboratory and a waste-treatment facility. The radiation protection organization of the Department is presented. Various methods of monitoring, including advantages and disadvantages are discussed. Emphasis is placed on the reactor chemistry laboratory where transuranic elements are utilized. These elements are highly radiotoxic and their monitoring in most cases requires destructive analysis. Different methods of determining external and internal doses are evaluated with regard to sensitivity and accuracy. Detection limits for radionuclides utilized in the laboratory are presented for different measurement systems, including non-destructive monitoring, spectrometry after chemical analysis, liquid scintillation counting and low-energy gamma spectrometry using a CsI-NaI scintillation detector. The guidelines laid down in the IAEA Safety Series Manuals are discussed in the light of practical experience. (author)

  7. Data acquisition system and analysis programme for environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    Rajaram, S.; Kannan, V.; Hegde, A.G.

    2003-01-01

    Full text: In every Environmental Survey Laboratory (ESL) many nuclear radiation detecting instruments such as low level Gas Flow Beta Counting Systems, Gross Alpha Counting Systems, Gamma Counting Systems (Single Channel Analyser) are in use to detect the environmental radiation level. These instruments give output in terms of number (total pulse event counts), which is further manually converted into activity concentration per unit weight of the environmental samples. There is considerable difficulty and delay in obtaining the data, since calculations are done manually and also it is very difficult to maintain database of these results for future reference. In order to overcome all this difficulties a Data Acquisition System and Analysing Software Programme has been designed and developed. This paper describes the design and development of the Data Acquisition System using PCL-830 Counter Timer add on card, for networking the environmental radioactivity monitoring equipment's, which is under routine operation at ESL Kalpakkam

  8. ANSTO radon monitoring within the WMO global atmosphere watch programme

    International Nuclear Information System (INIS)

    Zahorowski, W.; Chambers, S.; Sisoutham, O.; Werczynski, S.

    2003-01-01

    A brief overview of results from the ANSTO radon programmes at the Cape Grim (Tasmania) and Mauna Loa Observatory (Hawaii), World Meteorological Organisation Global Atmosphere Watch stations it presented. At Cape Grim, a 100 mBq m 3 threshold on radon concentration observations has proven to be a suitable criterion for Baseline monitoring. Furthermore, analysis of the Cape Grim Baseline radon data has enabled the characterisation of the oceanic radon flux over the Southern Ocean Cape Grim fetch region. Radon observations at the Mauna Loa Observatory, in conjunction with back trajectory analysis, have helped to identify the source regions of the most pervasive pollution events in the atmosphere of the Pacific Basin. The seasonal variability in the strength of terrestrial influence on Pacific air masses has also been characterised

  9. The MAFF dry cloth collector programme for monitoring airborne radioactivity

    International Nuclear Information System (INIS)

    McHugh, J.O.; Smith, B.D.; Hunt, G.J.; Thomas, R.E.G.

    1986-01-01

    The history of the MAFF airborne radioactivity monitoring programme and its current operation using dry cloth collectors are described. The detection system has become well established as a sensitive indicator of airborne radioactivity. Details of collector materials, deployment around the major UK nuclear establishments and procedures for radiometric analysis of cloths are given. Typical results for the period 1980-82 show that at most sites only nuclear weapons fallout was detected. The systems's usefulness is exemplified by its response to the release of I-131 from Sellafield in 1981; this release was of negligible radiological significance but was easily detected. The response of dry cloths to various sources of atmospheric radioactivity and factors affecting collection efficiency are discussed. (author)

  10. The Sines industrial complex monitoring programme: A preliminary report.

    Science.gov (United States)

    Jones, M P; Catarino, F M; Sérgio, C; Bento-Pereira, F

    1981-06-01

    It is anticipated that the establishment of the industrial complex at Sines, Alentejo, Portugal, will have some impact on the environment. Details of the methods used in the monitoring programme are provided. Records of the epiphytic lichen vegetation in permanent quadrats have been made and changes shown in selected sites over a three year period are discussed. Material has been collected for analysis for heavy metals and the results discussed. There is considerable variation in replicates and in interspecies values. The problem of age and bio-accumulation is mentioned. Scanning electron microscopy has shown the accumulation of particulates, as yet unidentified, the quantity varying with increase in age and surface texture. A broadly based study of the local epiphytic flora is being carried out to record the present day diversity. There appears, as yet, to be no detectable influence of the industrial complex on the epiphytic flora of the permanent quadrats.

  11. Physical Fault Injection and Monitoring Methods for Programmable Devices

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00510096; Ferencei, Jozef

    A method of detecting faults for evaluating the fault cross section of any field programmable gate array (FPGA) was developed and is described in the thesis. The incidence of single event effects in FPGAs was studied for different probe particles (proton, neutron, gamma) using this method. The existing accelerator infrastructure of the Nuclear Physics Institute in Rez was supplemented by more sensitive beam monitoring system to ensure that the tests are done under well defined beam conditions. The bit cross section of single event effects was measured for different types of configuration memories, clock signal phase and beam energies and intensities. The extended infrastructure served also for radiation testing of components which are planned to be used in the new Inner Tracking System (ITS) detector of the ALICE experiment and for selecting optimal fault mitigation techniques used for securing the design of the FPGA-based ITS readout unit against faults induced by ionizing radiation.

  12. Air quality monitoring programme. Annual summary for 2003

    International Nuclear Information System (INIS)

    Kemp, K.; Palmgren, F.

    2004-06-01

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO 2 , NO x /NO 2 , PM IO , lead, benzene, CO and ozone. Only a PM 10 monitor at an urban background location in Odense is missing. The data sets for year 2003 are almost complete for all stations. The monitoring programme consists of 10 stations plus 2 extra stations under the Municipality of Copenhagen. The limit value of the annual average of NO 2 was in 2003 exceeded at three street stations. At one station (Copenhagen/1103) the limit value + the margin of tolerance (56 μg/m 3 in 2003) was, exceeded. The trend seems to have been constant after several years of decrease. The ozone level was in 2003 - more or less - the same at all rural and urban background stations and no clear trend is observed. The information threshold on 180 μg/m 3 was not exceeded. The target values were not exceeded, but the long-term objectives of max 8 hours on 120 μg/m 3 were exceeded at all urban background and rural stations. The long term objective for AOT40 at 6000 μg/m 3 *hours were exceeded in a few Gases. The limit value of PM 10 on 50 μg/m 3 , not to be exceeded more than 35 times per year and to comply with in 2005, was in 2003 exceeded at 2 out of 4 street stations. At all stations both proposal limits values to be met in 2010 (annual average value on 20 μg/m 3 and 50 μg/m 3 not to be exceeded more than 7 times per year) were exceeded at all stations (including the rural station Keldsnor). PM 10 is 60-70% of TSP. The trend of TSP has been clear decreasing the last 15 years, except at HCAB. The SO 2 and lead levels are still decreasing and far below the limit values. The limit values for benzene and CO are not exceeded and the levels are Glose to the levels in year 2002. Actual data, quarterly reports, annual summaries and summaries over many year are available at the homepage of NERI on 'luft.dmu.dk'. (au)

  13. NOVANA - National Monitoring and Assessment Programme for the Aquatic and Terrestrial Environment

    DEFF Research Database (Denmark)

    Svendsen, L. M.

    This report is Part 1 of the Programme Description of NOVANA - the Nationwide Monitoring and Assessment Programme for the Aquatic and Terrestrial Environments. Part 1 comprises a general description of the background for the programme, including the international obliga-tions and requirements...... for monitoring of nature and the environment. The overall objective and the scientific and strategic background for the priorities upon which NOVANA pro-gramme is based are described, as are the organization of the programme, the overall economy and the technical assumptions made. Finally the scientific content...

  14. The socio-economic monitoring of the Ignalina Nuclear Power Plant region: methodology, programme, implementation

    International Nuclear Information System (INIS)

    Baubinas, R.; Burneika, D.; Daugirdas, V.

    2002-01-01

    The article is devoted to the argumentation of the main principles of socio-economic monitoring of the Ignalina NPP region. The programme and the territorial levels of the monitoring as well as the main results of the trial of the programme are presented. (author)

  15. Monitoring of radioactivity in the UK environment: an annotated bibliography of current programmes

    International Nuclear Information System (INIS)

    Cotter, A.J.R.; Hunt, G.J.

    1992-01-01

    In the UK, many organisations carry out regular radioactivity monitoring programmes, and summaries of these programmes have been published in 1983 and 1988. The number of organisations carrying out radioactivity monitoring has increased rapidly in recent years, particularly in the local authority sector. The present report updates the previous summarises in the form of an annotated bibliography, giving synopses of all regular UK programmes whose results are published in report form. (author)

  16. Marine environmental monitoring programmes in South Africa: a review

    Directory of Open Access Journals (Sweden)

    H. M. Verheye

    2010-01-01

    Full Text Available South Africa uniquely lies at the junction of two major currents, the Agulhas and the Benguela. The waters overlying the continental shelf exhibit exceptionally high short-, medium- and long-term (days to inter-decadal variability compared with most other shelf areas, and strongly contrasting oceanographic conditions are observed on the east and west coasts. South Africa is rich in fisheries resources and associated environmental data collected over more than a century. The South African marine scientific community has a history of multidisciplinary studies of marine foodwebs, from the driving forces such as wind, currents and solar heating, to the top predators, with the development of kelp bed, sub-tidal reefs and estuarine ecosystem studies in the 1970s; the Benguela Ecology Programme, which ran through four successive five-year stages, focused on the pelagic marine resources. Various approaches have been used to observe the continental shelf at different time and space scales, including: macroscale but frequent satellite imagery, mesoscale environmental and fishery surveys, dedicated crossshelf transects in key areas, measurements of dynamic processes, use of moored buoys and coastal weather stations, and integrated monitoring approaches, including modelling and simulation studies. Between 30 and 50 years of comprehensive marine data now exist, which are proving useful in the application of an ecosystem approach to fisheries monitoring and management, as decadal changes become discernible. These observations need to continue; even though the single-species stock assessment and operational management procedures have not yet formally used environmental factors for fisheries management advice, they help us to understand the factors affecting fish population fluctuations and early life histories and to identify large-scale regime shifts where marine trophic structure and functioning alter to a new state.

  17. Slit-lamp management in contact lenses laboratory classes: learning upgrade with monitor visualization of webcam video recordings

    Science.gov (United States)

    Arines, Justo; Gargallo, Ana

    2014-07-01

    The training in the use of the slit lamp has always been difficult for students of the degree in Optics and Optometry. Instruments with associated cameras helps a lot in this task, they allow teachers to observe and control if the students evaluate the eye health appropriately, correct use errors and show them how to do it with a visual demonstration. However, these devices are more expensive than those that do not have an integrated camera connected to a display unit. With the aim to improve students' skills in the management of slit lamp, we have adapted USB HD webcams (Microsoft Lifecam HD-5000) to the objectives of the slit lamps available in our contact lenses laboratory room. The webcams are connected to a PC running Linux Ubuntu 11.0; therefore that is a low-cost device. Our experience shows that single method has several advantages. It allows us to take pictures with a good quality of different conditions of the eye health; we can record videos of eye evaluation and make demonstrations of the instrument. Besides it increases the interactions between students because they could see what their colleagues are doing and take conscious of the mistakes, helping and correcting each others. It is a useful tool in the practical exam too. We think that the method supports the training in optometry practice and increase the students' confidence without a huge outlay.

  18. Policy issues for improving monitoring and evaluation of agricultural extension programmes in Nigeria

    Directory of Open Access Journals (Sweden)

    Akinnagbe O. Matthew

    2016-06-01

    Full Text Available Monitoring and evaluation are important, yet, frequently neglected functions in most organisations. In Nigeria, many programmes have been established over the years but only little monitoring and evaluation have been carried out because of many implementation problems and lack of realistic and/or stable policy framework. This paper was designed to X-ray policy issues for improving monitoring and evaluation of agricultural programmes in Nigeria. Inductive and deductive reasoning through a review of relevant literature was used in this philosophical paper. To improve the performance of agricultural extension programmes in Nigeria, the following policy issues must be addressed: The questions of what should be monitored or evaluated, when should monitoring and/or evaluation be carried out and who should monitor and/or evaluate; and the methodology to be adopted in any project should be included in any agricultural programmes and/or policies. Manpower and financial resources, effective communication and the issue of accountability must be properly considered. The tools for monitoring and evaluation are also very crucial. The paper concluded that planning a good agricultural programme is not a problem in Nigeria but poor implementation is, as a result of poor monitoring and evaluation. Therefore, attention should be on when, how and who should be involved in monitoring and evaluation.

  19. Manual of methods for use in the South African Marine Pollution Monitoring Programme

    CSIR Research Space (South Africa)

    Watling, RJ

    1981-07-01

    Full Text Available Methods used in the South African Marine Pollution Monitoring Programme for the analysis of toxic metals, nutrients, oxygen absorbed, chlorophyll, pesticides and bacteria are described. Sample types include biological material, sediments, estuarine...

  20. ''RESURS'' - The Russian scientific-technical programme for NPP equipment lifetime monitoring, estimation, prediction and management

    International Nuclear Information System (INIS)

    Emelyanov, V.

    1994-01-01

    RESURS programme is described implementation of which will allow to work out regulatory-methodological basis providing legal and technical solution of NPP equipment lifetime management, prediction, monitoring and estimation problems

  1. Ward based community road safety performance benchmarking, monitoring and intervention programmes in the City of Johannesburg

    CSIR Research Space (South Africa)

    Ribbens, H

    2008-07-01

    Full Text Available benchmarking, monitoring and intervention programme. Community road safety needs in the respective wards are articulated through the ward councillor. The rationale is that the community exactly knows where these problem areas are, because they suffer as a...

  2. Annual report on radioactive discharges and monitoring of the environment 1993. V. 2: Certificates of authorisation and environmental monitoring programmes

    International Nuclear Information System (INIS)

    1994-01-01

    British Nuclear Fuels plc's Certificates of Authorisation, under which it operates, are reproduced in the second volume of the 1993 Annual Report on Radioactive Discharges and Monitoring of the Environment. The report also includes environmental monitoring programmes relating to discharge authorisation for each of the Sellafield, Drigg, Chapelcross, Springfields and Capenhurst sites. (UK)

  3. International Cooperative Programme for Assessment and Monitoring of Acidification of Rivers and Lakes. Programme Manual

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, J.; Forsius, M.; Jeffries, D. [and others

    1996-12-31

    The International Cooperative Programme for Assessment of Acidification of Rivers and lakes (ICP Waters) was established in 1985 by the UN/ECE Executive Body for the Convention of Long-Range Transboundary Air Pollution. Achieving the programme objectives requires that both the temporally intensive and regionally extensive data are collected on a continuing basis. To guide the development and harmonization of the various national contributions, a manual was worked out. The present report is an expanded and consolidated revision of that manual. 33 refs., 3 tabs.

  4. Designing a benthic monitoring programme with multiple conflicting objectives

    NARCIS (Netherlands)

    Bijleveld, A.I.; van Gils, J.A.; van der Meer, J.; Dekinga, A.; Kraan, C.; van der Veer, H.W.; Piersma, T.

    2012-01-01

    1. Sound conservation and management advice usually requires spatial data on animal and plant abundances. The expense of programmes to determine species distributions and estimates of population sizes often limits sample size. To maximise effectiveness at minimal costs, optimisations of such

  5. Programme

    OpenAIRE

    Hobday, E, fl. 1905, artist

    2003-01-01

    A photograph of an illustrated programme listing dances. The illustration shows a snake charmer playing to a snake while another man watches. Buildings and trees can be seen behind a wall in the distance. In the lower right-hand corner of the programme is the signature 'E. Hobday'. The programme is almost certainly related to the Punjab Ball, Lahore. It is placed next to the Punjab Ball Menu in the album and the Menu is also illustrated by 'E. Hobday'.

  6. Development and implementation of a monitoring programme for ...

    African Journals Online (AJOL)

    36 of 1998) mandates the Department of Water and Sanitation (DWS) to undertake monitoring for the protection of water resources. ... of estuarine management plans which are a requirement of the Integrated Coastal Management Act (Act No.

  7. Optimising a fall out dust monitoring sampling programme at a ...

    African Journals Online (AJOL)

    GREG

    Key words: Fall out dust monitoring, cement plant, optimising, air pollution sampling, fall out dust sampler locations. .... applied for those areas where controls are in place. Sampling ..... mass balance in the total cement manufacturing process.

  8. The Danish air quality monitoring programme. Annual Summary for 2006

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellemann, T.; Brandt, J.; Christensen, Jesper; Ketzel, M.

    2007-06-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring (LMP) network. The aim has been to monitor the levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the concentration trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2006 the air quality was measured in four Danish cities and at two background sites. Besides this model calculations were carried out to supplement the measurements. NO{sub 2} and PM{sub 10} were at several stations found in concentrations above EU limit values, which the Member States have to comply 2005 and in 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a minor decrease has been observed for NO{sub 2} and O{sub 3}. (au)

  9. Circumpolar Biodiversity Monitoring Programme: Coastal Expert Workshop meeting summary

    Science.gov (United States)

    Thomson, L.; McLennan, Donald; Anderson, Rebecca D.; Wegeberg, S.; Pettersvik Arvnes, Maria; Sergienko, Liudmila; Behe, Carolina; Moss-Davies, Pitseolak; Fritz, S.; Christensen, T.; Price, C.

    2016-01-01

    The Coastal Expert Workshop brought together a diverse group of coastal experts with the common goal of developing a biodiversity monitoring program for coastal ecosystems across the circumpolar Arctic. Meeting participants, including northern residents, industry and Non-Governmental Organization (NGO) representatives, scientists, and government regulators from across the circumpolar Arctic, gathered at the Lord Elgin Hotel in Ottawa from March 1 to 3, 2016, to discuss current biodiversity monitoring efforts, understand key issues facing biodiversity in the Arctic coastal areas and suggest monitoring indicators, or Focal Ecosystem Components, for the program. A Traditional Knowledge Holders meeting was held on February 29, 2016 in conjunction with the workshop. The following document provides a summary of the workshop activities and outcomes, and will be followed by a more complete Workshop Report.

  10. Monitoring of radioactivity in the UK environment. An annotated bibliography of current programmes

    International Nuclear Information System (INIS)

    2001-01-01

    With the continuing use of radioactive materials in industry, research and medicine, the public's awareness about the potential impact on human health and safety of any enhanced levels of radiation in the environment has heightened. All those involved recognise this concern and there has developed over the years a network of comprehensive monitoring systems designed to determine the levels of radiation to which members of the public are exposed. In the UK, many organisations carry out regular radioactivity monitoring programmes, and summaries of these programmes have been published in 1983, 1988 and 1992. The number of organisations carrying out monitoring, particularly in the local authority sector, increased rapidly following the Chernobyl incident in 1986 and later levelled off. This report updates those previous summaries, giving synopses of regular UK programmes whose results are published in report form, and of which the Department of the Environment, Transport and the Regions is currently aware

  11. The Danish air quality monitoring programme. Annual Summary for 2007

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellemann, T.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2008-07-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2007 the air quality was measured in four Danish cities and at two background sites. Model calculations were also carried out to supplement the measurements. At several stations NO{sub 2} and PM{sub 10} were found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. The concentrations for most pollutants have been strongly decreasing since 1982, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (au)

  12. The Danish air quality monitoring programme. Annual summary for 2008

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellemann, T.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2010-06-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2007 the air quality was measured in four Danish cities and at two background sites. Model calculations were also carried out to supplement the measurements. At several stations NO{sub 2} and PM{sub 10} were found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. The concentrations for most pollutants have been strongly decreasing since 1982, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (author)

  13. Monitoring, reporting and verification for national REDD + programmes: two proposals

    International Nuclear Information System (INIS)

    Herold, Martin; Skutsch, Margaret

    2011-01-01

    Different options have been suggested by Parties to the UNFCCC (United Framework Convention on Climate Change) for inclusion in national approaches to REDD and REDD + (reduced deforestation, reduced degradation, enhancement of forest carbon stocks, sustainable management of forest, and conservation of forest carbon stocks). This paper proposes that from the practical and technical points of view of designing action for REDD and REDD + at local and sub-national level, as well as from the point of view of the necessary MRV (monitoring, reporting and verification), these should be grouped into three categories: conservation, which is rewarded on the basis of no changes in forest stock, reduced deforestation, in which lowered rates of forest area loss are rewarded, and positive impacts on carbon stock changes in forests remaining forest, which includes reduced degradation, sustainable management of forest of various kinds, and forest enhancement. Thus we have moved degradation, which conventionally is grouped with deforestation, into the forest management group reported as areas remaining forest land, with which it has, in reality, and particularly as regards MRV, much more in common. Secondly, in the context of the fact that REDD/REDD + is to take the form of a national or near-national approach, we argue that while systematic national monitoring is important, it may not be necessary for REDD/REDD + activities, or for national MRV, to be started at equal levels of intensity all over the country. Rather, areas where interventions seem easiest to start may be targeted, and here data measurements may be more rigorous (Tier 3), for example based on stakeholder self-monitoring with independent verification, while in other, untreated areas, a lower level of monitoring may be pursued, at least in the first instance. Treated areas may be targeted for any of the three groups of activities (conservation, reduced deforestation, and positive impact on carbon stock increases in

  14. Monitoring, reporting and verification for national REDD + programmes: two proposals

    Energy Technology Data Exchange (ETDEWEB)

    Herold, Martin [Center for Geoinformation, Department of Environmental Science, Wageningen University, Droevendaalsesteeg 3, 6708 PB Wageningen (Netherlands); Skutsch, Margaret, E-mail: martin.herold@wur.nl [Centro de Investigaciones en GeografIa Ambiental, UNAM Campus Morelia (Mexico)

    2011-01-15

    Different options have been suggested by Parties to the UNFCCC (United Framework Convention on Climate Change) for inclusion in national approaches to REDD and REDD + (reduced deforestation, reduced degradation, enhancement of forest carbon stocks, sustainable management of forest, and conservation of forest carbon stocks). This paper proposes that from the practical and technical points of view of designing action for REDD and REDD + at local and sub-national level, as well as from the point of view of the necessary MRV (monitoring, reporting and verification), these should be grouped into three categories: conservation, which is rewarded on the basis of no changes in forest stock, reduced deforestation, in which lowered rates of forest area loss are rewarded, and positive impacts on carbon stock changes in forests remaining forest, which includes reduced degradation, sustainable management of forest of various kinds, and forest enhancement. Thus we have moved degradation, which conventionally is grouped with deforestation, into the forest management group reported as areas remaining forest land, with which it has, in reality, and particularly as regards MRV, much more in common. Secondly, in the context of the fact that REDD/REDD + is to take the form of a national or near-national approach, we argue that while systematic national monitoring is important, it may not be necessary for REDD/REDD + activities, or for national MRV, to be started at equal levels of intensity all over the country. Rather, areas where interventions seem easiest to start may be targeted, and here data measurements may be more rigorous (Tier 3), for example based on stakeholder self-monitoring with independent verification, while in other, untreated areas, a lower level of monitoring may be pursued, at least in the first instance. Treated areas may be targeted for any of the three groups of activities (conservation, reduced deforestation, and positive impact on carbon stock increases in

  15. Developing and implementing a monitoring programme: recommendations provided by the MODERN project

    International Nuclear Information System (INIS)

    Mayer, S.; Bergmans, A.; Garcia-Sineriz, J.L.; Breen, B.; Jobmann, M.

    2012-01-01

    Document available in extended abstract form only. The successful implementation of a repository programme relies on both the technical aspects of a sound safety strategy, and scientific and engineering excellence, as well as on social aspects such as public acceptance. Monitoring has the potential to contribute to both of these aspects and thus to play an important role as national radioactive waste disposal programmes move forward towards safe and accepted implementation of geological disposal. The main goal of the 'Monitoring Developments for Safe Repository Operation and staged Closure' (MoDeRn) Project is to take the state-of-the-art of broadly accepted, main monitoring objectives and to develop these to a level of description that is closer to the actual implementation of monitoring during the staged approach of the disposal process. It should be noted that the MoDeRn project recognizes the diversity of monitoring activities that will be required in a repository, in particular related to operational safety, nuclear safeguards and environmental impact assessment. The projects emphasis, however, is on monitoring conducted to verify expected repository system evolutions - i.e. evolutions of the natural environment and the engineered system - during a phase of progressive construction, operation and closure that may last on the order of a century. This serves the purpose of confirming and possibly enhancing the prior license basis for safety and pre-closure management options. Achieving this goal includes analysis of whether the implementation of a realistic monitoring programme is likely to address expert and lay stakeholder expectations (objectives), to provide an understanding of monitoring activities and available technologies that can be implemented in a repository context (feasibility), and to provide recommendations for related, future stakeholder engagement activities (social acceptance). These are carried out by the 18 project partners representing 12

  16. Contract Management Monitoring And Evaluation Of Ghana School Feeding Programme At Atwima Kwanwoma District

    Directory of Open Access Journals (Sweden)

    Andrews Osei Mensah

    2015-08-01

    Full Text Available Ghana School Feeding Programme was introduced at Atwima Kwanwoma District and other parts of the country in 2008 to alleviate hunger and to provide good nutrition for pupils in the public basic schools. Caterers were given contract to provide food to the school pupils on every school-going day under Ghana school feeding programme. Some years have lapsed and there is the need to look back and evaluate this programme taking into consideration the award and management of those contracts. The study also examined how the programme is monitored and evaluated. Data was collected from 80 respondents comprising 29 school pupils and 51 other actors through the use of questionnaire and interview guide It was realised that caterers who are well experience in catering services were awarded contracts based on their past experience and financial abilities through submission of their certificates but not necessarily through bidding. The main component of managing the caterers contract included monitoring payment of debt and problems solving as well as supervision through visiting the schools on quarterly basis. The programme has helped to increase enrolment and retaining pupils in school. It was found out that food giving to the pupils was not served on time not regularly bases and was not sufficient to the pupils as well. The health component of the programme has not been successful as expected. It is recommended that fruits and variety of foods need to be introduced together with de-worming the pupils.

  17. Wood's lamp examination

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003386.htm Wood lamp examination To use the sharing features on this page, please enable JavaScript. A Wood lamp examination is a test that uses ultraviolet ( ...

  18. Wood's lamp illumination (image)

    Science.gov (United States)

    A Wood's lamp emits ultraviolet light and can be a diagnostic aid in determining if someone has a fungal ... is an infection on the area where the Wood's lamp is illuminating, the area will fluoresce. Normally ...

  19. Monitoring and evaluation of sport-based HIV/AIDS awareness programmes: Strengthening outcome indicators

    Directory of Open Access Journals (Sweden)

    Elma Nelisiwe Maleka

    2017-01-01

    Full Text Available There are number of Non-Governmental Organisations (NGOs in South Africa that use sport as a tool to respond to Human Immunodeficiency Virus/Acquired Immunodeficiency Syndrome (HIV/AIDS, however, little is reported about the outcomes and impact of these programmes. The aim of this study is to contribute to a generic monitoring and evaluation framework by improving the options for the use of outcome indicators of sport-based HIV/AIDS awareness programmes of selected NGOs in South Africa. A qualitative method study was carried out with seven employees of five selected NGOs that integrate sport to deliver HIV/AIDS programmes in South Africa. The study further involved six specialists/experts involved in the field of HIV/AIDS and an official from Sport Recreation South Africa (SRSA. Multiple data collection instruments including desktop review, narrative systematic review, document analysis, one-on-one interviews and focus group interview were used to collect information on outcomes and indicators for sport-based HIV/AIDS awareness programmes. The information was classified according to the determinants of HIV/AIDS. The overall findings revealed that the sport-based HIV/AIDS awareness programmes of five selected NGOs examined in this study focus on similar HIV prevention messages within the key priorities highlighted in the current National Strategic Plan for HIV/AIDS, STIs and TB of South Africa. However, monitoring and evaluating outcomes of sport-based HIV/AIDS programmes of the selected NGOs remains a challenge. A need exists for the improvement of the outcome statements and indicators for their sport-based HIV/AIDS awareness programmes. This study proposed a total of 51 generic outcome indicators focusing on measuring change in the knowledge of HIV/AIDS and change in attitude and intention towards HIV risk behaviours. In addition, this study further proposed a total of eight generic outcome indicators to measure predictors of HIV risk behaviour

  20. Monitoring and evaluation of sport-based HIV/AIDS awareness programmes: Strengthening outcome indicators.

    Science.gov (United States)

    Maleka, Elma Nelisiwe

    2017-12-01

    There are number of Non-Governmental Organisations (NGOs) in South Africa that use sport as a tool to respond to Human Immunodeficiency Virus/Acquired Immunodeficiency Syndrome (HIV/AIDS), however, little is reported about the outcomes and impact of these programmes. The aim of this study is to contribute to a generic monitoring and evaluation framework by improving the options for the use of outcome indicators of sport-based HIV/AIDS awareness programmes of selected NGOs in South Africa. A qualitative method study was carried out with seven employees of five selected NGOs that integrate sport to deliver HIV/AIDS programmes in South Africa. The study further involved six specialists/experts involved in the field of HIV/AIDS and an official from Sport Recreation South Africa (SRSA). Multiple data collection instruments including desktop review, narrative systematic review, document analysis, one-on-one interviews and focus group interview were used to collect information on outcomes and indicators for sport-based HIV/AIDS awareness programmes. The information was classified according to the determinants of HIV/AIDS. The overall findings revealed that the sport-based HIV/AIDS awareness programmes of five selected NGOs examined in this study focus on similar HIV prevention messages within the key priorities highlighted in the current National Strategic Plan for HIV/AIDS, STIs and TB of South Africa. However, monitoring and evaluating outcomes of sport-based HIV/AIDS programmes of the selected NGOs remains a challenge. A need exists for the improvement of the outcome statements and indicators for their sport-based HIV/AIDS awareness programmes. This study proposed a total of 51 generic outcome indicators focusing on measuring change in the knowledge of HIV/AIDS and change in attitude and intention towards HIV risk behaviours. In addition, this study further proposed a total of eight generic outcome indicators to measure predictors of HIV risk behaviour. The selected

  1. The Danish air quality monitoring programme. Annual summary for 2012

    Energy Technology Data Exchange (ETDEWEB)

    Ellermann, T.; Klenoe Noejgaard, J.; Nordstroem, C.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Jansen, S.; Massling, A.; Solvang Jensen, S.

    2013-10-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring network. The aim is to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to understand the governing processes that determine the level of air pollution in Denmark. In 2012 the air quality was measured in four Danish cities and at two background sites. In addition model calculations were carried out to supplement the measurements. At one street station (H.C. Andersens Boulevard) in Copenhagen NO{sub 2} was found in concentrations above EU limit values while NO{sub 2} levels in Odense, Aarhus and Aalborg were below the limit value. Model calculations indicate exceedances of NO{sub 2} limit values at several streets in Copenhagen. Annual averages of PM{sub 10} and PM{sub 2.5} were below limit values at all stations. The concentrations for most pollutants have been decreasing during the last decades. (Author)

  2. The Danish air quality monitoring programme. Annual summary for 2011

    Energy Technology Data Exchange (ETDEWEB)

    Ellemann, T.; Klenoe Noejgaard, J.; Nordstroem, C.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2012-10-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring network. The aim is to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to understand the governing processes that determine the level of air pollution in Denmark. In 2011 the air quality was measured in four Danish cities and at two background sites. In addition model calculations were carried out to supplement the measurements. At one street station (H.C. Andersens Boulevard) in Copenhagen NO{sub 2} was found in concentrations above EU limit values while NO{sub 2} levels in Odense, Aarhus and Aalborg were below the limit value. Model calculations indicate exceedances of NO{sub 2} limit values at several streets in Copenhagen. Annual averages of PM{sub 10} and PM{sub 2.5} were below limit values at all stations. However, concentrations levels in Copenhagen exceeded the daily limit value for PM{sub 10}. Winter salting of roads was one of the main reasons for this exceedance. The concentrations for most pollutants have been strongly decreasing during the last decades, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (Author)

  3. The Danish air quality monitoring programme. Annual summary for 2005

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellermann, T.; Palmgren, F.; Waehlin, P.

    2006-06-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2005 the air quality was measured in four Danish cities and at two background sites. NO{sub 2} and PM{sub 10} were at several stations found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a slight decrease has been observed for NO{sub 2}. (au)

  4. The Danish air quality monitoring programme. Annual summary for 2005

    International Nuclear Information System (INIS)

    Kemp, K.; Ellermann, T.; Palmgren, F.; Waehlin, P.

    2006-06-01

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2005 the air quality was measured in four Danish cities and at two background sites. NO 2 and PM 10 were at several stations found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a slight decrease has been observed for NO 2 . (au)

  5. Air quality monitoring programme. Annual summary for 2004

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellermann, T.; Palmgren, F.; Waehlin, P.; Berkowicz, R. Brandt. j.

    2005-07-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2004 the air quality was measured in four Danish cities and at two background sites. NO{sup 2} and PM10 were at several stations found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a slight decrease has been observed for NO{sup 2}. The measurement has been supplemented with dispersion models for a number of streets in Copenhagen and Aalborg. (au)

  6. Monitoring and Evaluation of an Early Childhood Development Programme: Implications for Leadership and Management

    Science.gov (United States)

    Hodgson, Sarah; Papatheodorou, Theodora; James, Mary

    2014-01-01

    The article aims to discuss preliminary findings from a participatory monitoring and evaluation (M&E) framework, used in a community-based early childhood development (ECD) programme in KwaZulu-Natal South Africa, and their implications for leadership and management. The purposes of the M&E were for LETCEE, the implementing organization,…

  7. Lichen elements as pollution indicators: evaluation of methods for large monitoring programmes

    Science.gov (United States)

    Susan Will-Wolf; Sarah Jovan; Michael C. Amacher

    2017-01-01

    Lichen element content is a reliable indicator for relative air pollution load in research and monitoring programmes requiring both efficiency and representation of many sites. We tested the value of costly rigorous field and handling protocols for sample element analysis using five lichen species. No relaxation of rigour was supported; four relaxed protocols generated...

  8. Web system for dosimetric data management of internal monitoring programme at IPEN

    International Nuclear Information System (INIS)

    Lima, Vanesa R. de; Rodriguez Junior, Orlando; Todo, Alberto S.

    2008-01-01

    Full text: The internal monitoring programme are carried out for the occupationally exposed workers that develop activities in the radioisotope production plant, fuel cycle facilities, waste management installations, cyclotron and the reactor facility at Institute of Nuclear Energy and Research (IPEN). According to the National Nuclear Energy Commission (CNEN), Regulation NN-3.01, the dose of each worker should be maintained at least for a period of 30 years. With this purpose, an online system, called 'IntDosWeb', was developed with the objective of the management for data dosimetric of internal monitoring programme. The system IntDosWeb, based on free software, was developed in programming language PHP and environment database PostgreSQL. This system is to be available at the local net, Intranet. The database maintains information about identification of the worker that handles non-sealed radioactive sources, physical and chemical characteristics of the radionuclides, monitoring types, measurement data and the dose. This system is able to generate annual reports of the individuals and the historical dose. Several simulation cases have been put into effect to check the on-line software functional capabilities. The users can access the dosimetric information according to following database field: monitoring period, monitoring type, intake pattern, radionuclide type and monitoring data from a specific installation or from each worker. The system was tested in the routinely service of internal dosimetry at IPEN. The rastreability of the information made in the internal monitoring programme was a success and also guaranteeing the reliability and integrity of the stored information. The IntDosWeb was shown as a helpful tool for analysis of the committed effective dose in the radiation protection programme, besides obeying the legal demands of the Brazilian Regulatory Commission. (author)

  9. Spatial scan statistics to assess sampling strategy of antimicrobial resistance monitoring programme

    DEFF Research Database (Denmark)

    Vieira, Antonio; Houe, Hans; Wegener, Henrik Caspar

    2009-01-01

    Pie collection and analysis of data on antimicrobial resistance in human and animal Populations are important for establishing a baseline of the occurrence of resistance and for determining trends over time. In animals, targeted monitoring with a stratified sampling plan is normally used. However...... sampled by the Danish Integrated Antimicrobial Resistance Monitoring and Research Programme (DANMAP), by identifying spatial Clusters of samples and detecting areas with significantly high or low sampling rates. These analyses were performed for each year and for the total 5-year study period for all...... by an antimicrobial monitoring program....

  10. Optimization of internal contamination monitoring programmes by studying uncertainties linked to dosimetric assessment

    International Nuclear Information System (INIS)

    Davesne, Estelle

    2010-01-01

    To optimise the protection of workers against ionizing radiations, the International Commission on Radiological Protection recommends the use of dose constraint and limits. To verify the compliance of the means of protection with these values when a risk of internal contamination exists, monitoring programmes formed of periodic bioassay measurements are performed. However, uncertainty in the dose evaluation arises from the variability of the activity measurement and from the incomplete knowledge of the exposure conditions. This uncertainty was taken into account by means of classical, Bayesian and possibilist statistics. The developed methodology was applied to the evaluation of the potential exposure during nuclear fuel preparation or mining; and to the analysis of the monitoring programme of workers purifying plutonium in AREVA NC La Hague reprocessing plant. From the measurement decision threshold, the minimum dose detectable (MDD) by the programme with a given confidence level can be calculated through the software OPSCI. It is shown to be a useful support in the optimisation of monitoring programmes when seeking a compromise between their sensitivity and their costs. (author)

  11. Monitoring and evaluation of strategic change programme implementation-Lessons from a case analysis.

    Science.gov (United States)

    Neumann, Jan; Robson, Andrew; Sloan, Diane

    2018-02-01

    This study considered the monitoring and evaluation of a large-scale and domestic and global strategic change programme implementation. It considers the necessary prerequisites to overcome challenges and barriers that prevent systematic and effective monitoring and evaluation to take place alongside its operationalisation. The work involves a case study based on a major industrial company from the energy sector. The change programme makes particular reference to changes in business models, business processes, organisation structures as well as Enterprise Resource Planning infrastructure. The case study focussed on the summative evaluation of the programme post-implementation. This assessment involved 25 semi-structured interviews with employees across a range of managerial strata capturing more than 65 roles within the change programme at both local and global levels. Data relating to their perception of evaluation effectiveness and shortcomings were analysed by means of template analysis. The study identifies responsibilities for executing an evaluation alongside various methods and tools that are appropriate, thereby focussing on the "Who" (roles, responsibility for particular activities) and "How" (methods and tools) rather than "What" to monitor and evaluate. The findings are presented generically so they offer new insights and transferability for practitioners involved in managing strategic change and its associated evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Global ocean monitoring for the World Climate Research Programme.

    Science.gov (United States)

    Revelle, R; Bretherton, F

    1986-07-01

    -"Tropical Oceans and Global Atmosphere (TOGA)"-will be undertaken to sudy the sequence of events of air-sea interactions in the tropical oceans and their impact on climatic variations on land-for example, variations in the strength and location of the Indian Ocean monsoon, droughts in low latitudes, and climatic fluctuations in temperate latitudes.Experimental and continuing time series will be taken at fixed locations to obtain a better picture of the magnitude and causes of ocean climate variability. National and multinational systematic repeated measurements along selected ocean transects or in specific ocean areas will be taken to determine oceanic variability and teleconnections between oceanic and atmospheric processes. Examples are the long Japanese section along the meridian of 137° E and the 'Sections' program of the USSR and several other countries in Energy-Active zones.The results from this wide range of observations and experiments will be used to guide and define mathematical models of the ocean circulation and its interactions with the atmosphere.It can be shown that biogeochemical processes in the ocean play an important role in determining the carbon dioxide content of the atmosphere and thus in causing long-term climatic changes. Variations in the biological productivity of sub-surface waters cause variations in the effectveness of the biological pump which carries organic carbon down into deeper waters where it is oxidized. Studies of ice cores from 20 000 to 30 000 yr before the present indicate that atmospheric carbon dioxide varied by a factor of 2 within times of the order of 100 yr, and these variations were accompanied by large excursions in atmospheric temperature. Thus, ocean climatic monitoring must take into account measurements of both biological and physical variations in the ocean.

  13. Economic comparison of the monitoring programmes for bluetongue vectors in Austria and Switzerland.

    Science.gov (United States)

    Pinior, B; Brugger, K; Köfer, J; Schwermer, H; Stockreiter, S; Loitsch, A; Rubel, F

    2015-05-02

    With the bluetongue virus serotype 8 (BTV-8) outbreak in 2006, vector monitoring programmes (according to EU regulation 1266/2007) were implemented by European countries to obtain information on the spatial distribution of vectors and the vector-free period. This study investigates the vector monitoring programmes in Austria and Switzerland by performing a retrospective cost analysis for the period 2006-2010. Two types of costs were distinguished: costs financed directly via the national bluetongue programmes and costs contributed in-kind by the responsible institutions and agricultural holdings. The total net costs of the monitoring programme in Austria amounted to €1,415,000, whereby in Switzerland the costs were valued at €94,000. Both countries followed the legislation complying with requirements, but differed in regard to sampling frequency, number of trap sites and sampling strategy. Furthermore, the surface area of Austria is twice the area of Switzerland although the number of ruminants is almost the same in both countries. Thus, for comparison, the costs were normalised with regard to the sampling frequency and the number of trap sites. Resulting costs per trap sample comprised €164 for Austria and €48 for Switzerland. In both countries, around 50 per cent of the total costs can be attributed to payments in-kind. The benefit of this study is twofold: first, veterinary authorities may use the results to improve the economic efficiency of future vector monitoring programmes. Second, the analysis of the payment in-kind contribution is of great importance to public authorities as it makes the available resources visible and demonstrates how they have been used. British Veterinary Association.

  14. Monitoring sterile and wild insects in area-wide integrated pest management programmes

    International Nuclear Information System (INIS)

    Vreysen, M.J.B.

    2005-01-01

    Insect pest control programmes, which integrate the release of sterile insects, can be efficient only if the released insects have an optimal biological quality. Frequent monitoring of the quality of reared insects after being released in the field is an important but often neglected component of area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Parameters of sterile insects, which should be monitored regularly, are sexual competitiveness of the released insects, and related components, e.g. survival, mobility, dispersal characteristics, and spatial occupation of the habitat. A well-balanced monitoring programme will, at any given time, provide essential feedback on the progress being made. This information is prerequisite to efficient implementation of the release and cost-efficient use of sterile insects. The type of monitoring to be done will be determined largely by the particular biology of the target insect species. The most important parameter in relation to the release of sterile insects is the rate of sterility induced in the wild insect pest population; it will provide the best evidence that any observed changes, e.g. in the density of the target insect, are caused by the release of sterile insects. (author)

  15. A computer programme to monitor the performance of an X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Simpolo, G.F.

    1985-01-01

    A BASIC computer programme has been developed that measures the long- and short-term stability of an X-ray spectrometer and operational errors (and compares them with the limits specified by the manufacturer) and the dead time of the associated detectors. The programme also carries out checks on the spectrometer with regard to the performance of different combinations of the crystals, the detectors, the collimators, the sin 2 THETA angles, the apertures, the tracking of the sin 2 THETA amplifier, the operation of the second-order spectrum circuits, the operation of the automatic pulse-height analyser, the condition of the detectors, the condition of the X-ray tube, spectral contamination by the tube spectrum, and physical contamination by analytical specimens. Although the measurements take 15 hours, there is no disruption to normal, routine laboratory work since the measurements can be made automatically after routine work has been completed. Only four sample positions are required for this monitoring programme

  16. Quality of care in reproductive health programmes: monitoring and evaluation of quality improvement.

    Science.gov (United States)

    Kwast, B E

    1998-12-01

    As 200 million women become pregnant every year, at least 30 million will develop life-threatening complications requiring emergency treatment at any level of society where they live. But it is a basic human right that pregnancy be made safe for all women as complications are mostly unpredictable. This requires reproductive health programmes which are responsive to women's and their families' needs and expectations on the one hand and enhancement of community participation, high quality obstetric services, and both provider collaboration and satisfaction on the other. Monitoring and evaluation of these facets need to be an integral part of any safe motherhood programme, not only to assess progress, but also to use this information for subsequent planning and implementation cycles of national programmes. Lessons learned from ten years' implementation of Safe Motherhood programmes indicate that process and outcome indicators are more feasible for short-term evaluation purposes than impact indicators, such as maternal mortality reduction. The former are described in this paper with relevant country examples. This is the third, and last, article in a series on quality of care in reproductive health programmes. The first (Kwast 1998a) contains an overview of concepts, assessments, barriers and improvements of quality of care. The second (Kwast 1998b) addresses education issues for quality improvement.

  17. Qualification, monitoring, and integration into a production environment of the world's first fully programmable illuminator

    Science.gov (United States)

    McIntyre, Gregory; Corliss, Daniel; Groenendijk, Remco; Carpaij, Rene; van Niftrik, Ton; Landie, Guillaume; Tamura, Takao; Pepin, Thomas; Waddell, James; Woods, Jerry; Robinson, Chris; Tian, Kehan; Johnson, Richard; Halle, Scott; Kim, Ryoung-Han; Mclellan, Erin; Kato, Hirokazu; Scaduto, Anthony; Maier, Carl; Colburn, Matt

    2011-04-01

    This paper will describe the development, qualification, monitoring, and integration into a production environment of the world's first fully programmable illuminator for optical lithography. FlexRay TM, a programmable illuminator based on a MEMs multi-mirror array that was developed for TWINSCAN XT:19x0i and TWINSCAN NXT series ASML immersion scanners, was first installed in January 2010 at Albany Nanotech, with subsequent tools installed in IBM's East Fishkill Manufacturing facility. After a brief overview of the concept and benefits of FlexRay, this paper will provide a comprehensive assessment of its reliability and imaging performance. A CD-based pupil qualification (CDPQ) procedure will be introduced and shown to be an efficient and effective way to monitor pupil performance. Various CDPQ and in-resist measurement results will be described, offering convincing evidence that FlexRay reliably generates high-quality pupils and is well suited for high volume manufacturing at lithography's leading edge.

  18. Discharge lamp technologies

    Science.gov (United States)

    Dakin, James

    1994-01-01

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advances.

  19. A programmable point-of-care device for external CSF drainage and monitoring.

    Science.gov (United States)

    Simkins, Jeffrey R; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.

  20. Use of a trypanosomal antigen ELISA to monitor tsetse and trypanosomosis control programmes in Kenya

    Energy Technology Data Exchange (ETDEWEB)

    Olaho-Mukani, W; Munga, L K; Nyanga` O, J N.M.; Ouma, J O; Masika, P; Okech, G; Ndungu, J M [Kenya Trypanosomiasis Research Inst., Kikuyu (Kenya)

    1997-02-01

    The capture Antigen-ELISA was used to monitor serum samples originating from three study areas in Kenya. At the Galana ranch the test was used to assess re-invasion of an area previously cleared of Glossina pallidipes. In Busia district the Ag-ELISA is being used to monitor the progress of a tsetse and trypanosomosis control programme. At Taita and Tara ranches the capture Antigen ELISA and the buffy coat technique (BCT) were used to evaluate the efficacy of a commercial Cypermethrin dip for the control of Glossina pallidipes. (author). 3 refs, 4 figs, 2 tabs.

  1. Lamp reliability studies for improved satellite rubidium frequency standard

    Science.gov (United States)

    Frueholz, R. P.; Wun-Fogle, M.; Eckert, H. U.; Volk, C. H.; Jones, P. F.

    1982-01-01

    In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.

  2. Geometric Modelling of Octagonal Lamp Poles

    Science.gov (United States)

    Chan, T. O.; Lichti, D. D.

    2014-06-01

    Lamp poles are one of the most abundant highway and community components in modern cities. Their supporting parts are primarily tapered octagonal cones specifically designed for wind resistance. The geometry and the positions of the lamp poles are important information for various applications. For example, they are important to monitoring deformation of aged lamp poles, maintaining an efficient highway GIS system, and also facilitating possible feature-based calibration of mobile LiDAR systems. In this paper, we present a novel geometric model for octagonal lamp poles. The model consists of seven parameters in which a rotation about the z-axis is included, and points are constrained by the trigonometric property of 2D octagons after applying the rotations. For the geometric fitting of the lamp pole point cloud captured by a terrestrial LiDAR, accurate initial parameter values are essential. They can be estimated by first fitting the points to a circular cone model and this is followed by some basic point cloud processing techniques. The model was verified by fitting both simulated and real data. The real data includes several lamp pole point clouds captured by: (1) Faro Focus 3D and (2) Velodyne HDL-32E. The fitting results using the proposed model are promising, and up to 2.9 mm improvement in fitting accuracy was realized for the real lamp pole point clouds compared to using the conventional circular cone model. The overall result suggests that the proposed model is appropriate and rigorous.

  3. Lamp for sunshine simulation

    DEFF Research Database (Denmark)

    2016-01-01

    A lamp system is provided, comprising a lamp with a lamp housing accommodating a plurality of light sources for emission of visible light, including blue light, a time keeping unit, a light sensor for sensing intensity of light incident upon it, and a light controller configured for controlling...... the plurality of light sources in response to the intensity of light sensed by the light sensor and the time provided by the time keeping unit, characterized in that the lamp emits blue light for a selected time period, wherein the blue light has a luminous flux ranging from 50 lux to 200 lux and, preferably......, an irradiance that is larger than 5 mW/nm/m2 in a selected wavelength range, such as in the wavelength range from 440 nm to 500 nm, as measured at a distance of 3 metres from the lamp....

  4. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Science.gov (United States)

    2010-10-01

    ... Devices, and Electrical Wiring § 393.24 Requirements for head lamps, auxiliary driving lamps and front fog lamps. (a) Headlamps. Every bus, truck and truck tractor shall be equipped with headlamps as required by...

  5. Contaminant monitoring programmes using marine organisms: Quality assurance and good laboratory practice

    International Nuclear Information System (INIS)

    1990-01-01

    This publication provides guidelines for obtaining reliable and relevant data during monitoring programmes in which contaminants are measured in marine organisms. It describes the precautions to be taken in each of the procedural steps from planning and sampling to the publication of data reports. The purpose of this document is to provide general guidance on quality assurance and to outline the approach that could be taken by laboratories to achieve the specific aims(s) for each marine pollution monitoring programme. Since most laboratories are currently focussing on programmes involving marine organisms, this document will be confined to this aspect. Four main aims can be identified for programmes involving the collection and analysis of marine organisms for the three main groups of contaminants (metals, organochlorine compounds and petroleum hydrocarbons), these are: (i) The measurement of contaminant levels in edible marine organisms in relation to public health; (ii) The identification of heavily contaminated areas of the sea (''hot spots'') where levels of contaminants are at least an order of magnitude higher than levels in clean or uncontaminated areas; (iii) The establishment of present levels of contaminants in marine organisms (i.e., a ''baseline''); (iv) The assessment of changes in concentrations of contaminants in organisms over a period of time (trends). The selection of organisms will be dictated by the eating patterns of the population. These can be identified by a survey of the species sold at the market, by obtaining information from colleagues in government departments who deal with such matters or in the absence of such information, by distributing a questionnaire to a representative section of the general public. 9 refs, 4 figs

  6. Capacitive discharge exciplex lamps

    Energy Technology Data Exchange (ETDEWEB)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F [High Current Electronics Institute, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2005-09-07

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications.

  7. Capacitive discharge exciplex lamps

    International Nuclear Information System (INIS)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F

    2005-01-01

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications

  8. Hollow-Core Fiber Lamp

    Science.gov (United States)

    Yi, Lin (Inventor); Tjoelker, Robert L. (Inventor); Burt, Eric A. (Inventor); Huang, Shouhua (Inventor)

    2016-01-01

    Hollow-core capillary discharge lamps on the millimeter or sub-millimeter scale are provided. The hollow-core capillary discharge lamps achieve an increased light intensity ratio between 194 millimeters (useful) and 254 millimeters (useless) light than conventional lamps. The capillary discharge lamps may include a cone to increase light output. Hollow-core photonic crystal fiber (HCPCF) may also be used.

  9. Monitoring Programme of Radionuclide Migration Through Food Chains at Low and Intermediate Level Radioactive Waste Repository in Trgoska Gora Mountain

    International Nuclear Information System (INIS)

    Schaller, A.; Lokner, V.; Kucar Dragicevic, S.; Subasic, D.; Barisic, D.

    2001-01-01

    Full text: Basic objective of the paper is to prepare a comprehensive programme of monitoring at the preferred site for low and intermediate level radioactive waste repository in the region of Trgovska Gora mountain. The programme is based on available information regarding hydrogeology, lithostratigraphy, tectonics, seismotectonics, geomorphology, meteorology, bioecology, demography and other site relevant disciplines. It is supposed to ensure (1) identification of the zero state at the broader region of the Trgovska gora mountain, and (2) to underline activities needed for monitoring of concentrations of expected radionuclides throughout possible pathways (particularly through food chains) that would migrate to the biosphere in the period after start of radioactive waste repository operation. Inventory of radionuclides contained in the radioactive waste to be disposed of at the site is naturally an important element of the programme structure. There should be identified those radionuclides which concentrations require to be monitored. Concentration measuring methods are proposed in the article. In addition, relevant aquatic and terrestrial organisms, serving as bioindicators, are identified. Types, quantities, frequency and methodology of sampling present an important part of the monitoring programme. Determination of monitoring sites for undertaking particular types of sampling (e.g. stream waters, stream sediment, detritus, ichtiofauna, groundwater, terrestrial organisms, honey, etc.), presenting an important aspect of a well-organised monitoring programme, is also included into this presentation. (author)

  10. Monitoring programmes for unrestricted release related to decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    1992-01-01

    Decommissioning of nuclear facilities usually results in a large volume of radioactive and non-radioactive materials. All these materials will have to be segregated as radioactive, non-radioactive and exempt from regulatory control, and then disposed of, reused or recycled. As more and more facilities approach decommissioning, controlling these wastes and setting release criteria and limits for these materials will represent a major task for the regulatory body and the licensee. Efforts are, therefore, under way at the IAEA to help achieve international consensus on the release criteria for decommissioning and a monitoring programme to verify compliance with these criteria. Within the above context, the present report was conceived as a technical document to provide an overview of all the factors to be considered in the development, planning and implementation of a monitoring programme to assure regulatory compliance with criteria for unrestricted release of materials, buildings and sites from decommissioning. The report is intended as a planning document for the owners, operators and regulatory bodies involved in decommissioning. 41 refs, 4 figs, 2 tabs

  11. Post-release monitoring of Antillean manatees: an assessment of the Brazilian rehabilitation and release programme

    Science.gov (United States)

    Normande, Iran C.; Malhado, Ana C. M.; Reid, James P.; Viana Junior, P.C.; Savaget, P. V. S.; Correia, R. A.; Luna, F. O.; R. J. Ladle,

    2016-01-01

    Mammalian reintroduction programmes frequently aim to reconnect isolated sub-populations and restore population viability. However, these long-term objectives are rarely evaluated due to the inadequacy of post-release monitoring. Here, we report the results of a unique long term telemetry-based monitoring programme for rehabilitated Antillean manatees (Trichechus manatus manatus) reintroduced into selected sites in northeast Brazil with the aim of reconnecting isolated relict populations. Twenty-one satellite-tagged rehabilitated manatees, 13 males and 8 females, were released into the wild from two sites between November 2008 and June 2013. Individual accumulation curves were plotted and home ranges were calculated through the fixed kernel method using 95% of the utilization distribution. The number and size of the Centres of Activity (COAs) were calculated using 50% of the utilization distribution. Manatees displayed a dichotomous pattern of movement, with individuals either characterized by sedentary habits or by much more extensive movements. Moreover, home range size was not significantly influenced by gender, age at release or release site. COAs were strongly associated with sheltered conditions within reefs and estuaries, and also by the presence of freshwater and feeding sites. Our data confirm that manatee reintroductions in Brazil have the potential to reconnect distant sub-populations. However, pre-release identification of potential long-distance migrants is currently unfeasible, and further analysis would be required to confirm genetic mixing of distant sub-populations.

  12. Overview of the Belgian programme for the surveillance of the territory and the implications of the international recommendations or directives on the monitoring programme

    International Nuclear Information System (INIS)

    Sombre, L.; Lambotte, J.M.

    2004-01-01

    The Royal Decree of 20 th July has entrusted the Federal Agency for Nuclear Control (FANC) with the task of controlling the territorial radioactivity and the doses received by the population. Within this agenda, a monitoring programme has been developed over many years, in order to follow the main potential exposure pathways of the population. In practice, several potential vectors of contamination are controlled: air (and rain), surface water (including sediments and biota), soils around nuclear installations, food chain, drinking water etc. To carry out such work, the FANC has collaborated with public or private reputable organisations: The Centre of Nuclear Energy Studies of Mol, The National Institute of Radionuclides of Fleurus, and The Louis Pasteur Public Health Institute of Brussels. A synthesis of this monitoring programme will be presented and the most important deductions will be pointed out. For many years, the tendency has been for tighter control of artificial and natural radioactivity in the environment. This has been achieved by increasingly stringent regulations, regarding environmental monitoring efforts, from international organisations (EC, OSPAR, IAEA). In this context, the FANC in Belgium, is involved in a process that will lead to the adaptation of the Belgian monitoring programme. Different aspects of these adaptations and of their consequences will be presented for illustrative purposes

  13. Lamps recycling aiming at the environment preservation

    International Nuclear Information System (INIS)

    Yamachita, Roberto Akira; Gama, Paulo Henrique R. Pereira; Haddad, Jamil; Santos, Afonso H. Moreira; Guardia, Eduardo C.

    1999-01-01

    The article discusses the following issues of lamps recycling in Brazil: mercury lamps recycling, recycling potential, energy conservation and environmental impacts, enterprises lamps recycling, and incentives policy

  14. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  15. The co-ordinated programme for research and monitoring of pollution in the Mediterranean

    International Nuclear Information System (INIS)

    Civili, F.S.; Jeftic, L.

    1987-01-01

    The turnover rate of water in the Mediterranean is explained, and the problem of pollution is identified. The Mediterranean Action Plan which was approved in 1975, has three main elements: environmental legislation, environmental management and environmental assessments. The environmental assessment component is a coordinated programme involving groups and institutions in 16 countries. The longterm objectives are stated and the activities undertaken are given. Four types of monitoring are being carried out - of sources, of coastal areas, of reference areas and of the transport of pollutants to the Mediterranean Sea through the atmosphere. The research activities are outlined and the resulting reports are considered. The state of pollution is assessed and the measures proposed to solve the problems are given. In particular, mercury pollution is explained. (UK)

  16. Eurados self-sustained programme of intercomparisons for individual monitoring services

    International Nuclear Information System (INIS)

    Grimbergen, T. W. M.; Figel, M.; Romero, A. M.; Stadtmann, H.; McWhan, A. F.

    2011-01-01

    Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters. (authors)

  17. Elsam. Offshore Wind Turbines. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2004 - 31. December 2004

    International Nuclear Information System (INIS)

    2005-07-01

    In 2001, the former Ministry of the Environment and Energy granted Elsam A/S and Eltra A.m.b.A. approval to establish a wind farm capable of producing 160 MW of electric power, at Horns Rev, west of Blaevandshuk at the west coast of Jutland. According to the conditions of the approval, Elsam and Eltra were required to monitor the environmental effects of the wind farm by performing monitoring before, during and after construction of the wind farm. The environmental monitoring programme is financed through Public Service Obligation (PSO). Analogue to the Horns Rev wind farm another offshore demonstrational wind farm was established in the Baltic sea south of Lolland by Energi E2 the Nysted 165 MW offshore wind farm. To coordinate the environmental monitoring at the two demonstration wind farms at Nysted and Horns Rev within the framework of the approved budget, the Environmental Group of Danish Offshore Wind Farm Demonstration Projects was set up. The group consists of representatives from the Danish Forest and Nature Agency, the Danish Energy Authority, Elsam and Energi E2. The Environmental Group initiates, monitors and evaluates the environmental programmes continuously with respect to possible improvements and intensifications to ensure that the design of the individual programmes is optimal. After evaluation, the monitoring programmes are proposed by the Environmental Group and carried out after final approval by the Danish Energy Authority. The Environmental Group considers if there is reason to adjust the issues and priorities of the programmes based on previous experience or other inputs eg from the international expert panel, IAPEME (International Advisory Panel of Experts on Marine Ecology). IAPEME evaluates the environmental monitoring programmes and makes valuable suggestions and recommendations to the Environmental Group. The programmes have concentrated on the monitoring of possible impacts before, during and after construction to investigate and

  18. Elsam. Offshore Wind Turbines. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2004 - 31. December 2004

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-15

    In 2001, the former Ministry of the Environment and Energy granted Elsam A/S and Eltra A.m.b.A. approval to establish a wind farm capable of producing 160 MW of electric power, at Horns Rev, west of Blaevandshuk at the west coast of Jutland. According to the conditions of the approval, Elsam and Eltra were required to monitor the environmental effects of the wind farm by performing monitoring before, during and after construction of the wind farm. The environmental monitoring programme is financed through Public Service Obligation (PSO). Analogue to the Horns Rev wind farm another offshore demonstrational wind farm was established in the Baltic sea south of Lolland by Energi E2 the Nysted 165 MW offshore wind farm. To coordinate the environmental monitoring at the two demonstration wind farms at Nysted and Horns Rev within the framework of the approved budget, the Environmental Group of Danish Offshore Wind Farm Demonstration Projects was set up. The group consists of representatives from the Danish Forest and Nature Agency, the Danish Energy Authority, Elsam and Energi E2. The Environmental Group initiates, monitors and evaluates the environmental programmes continuously with respect to possible improvements and intensifications to ensure that the design of the individual programmes is optimal. After evaluation, the monitoring programmes are proposed by the Environmental Group and carried out after final approval by the Danish Energy Authority. The Environmental Group considers if there is reason to adjust the issues and priorities of the programmes based on previous experience or other inputs eg from the international expert panel, IAPEME (International Advisory Panel of Experts on Marine Ecology). IAPEME evaluates the environmental monitoring programmes and makes valuable suggestions and recommendations to the Environmental Group. The programmes have concentrated on the monitoring of possible impacts before, during and after construction to investigate and

  19. Fluorescent discharge lamp

    Science.gov (United States)

    Mukai, E.; Otsuka, H.; Nomi, K.; Honmo, I.

    1982-01-01

    A rapidly illuminating fluorescent lamp 1,200 mm long and 32.5 mm in diameter with an interior conducting strip which is compatible with conventional fixtures and ballasts is described. The fluorescent lamp is composed of a linear glass tube, electrodes sealed at both ends, mercury and raregas sealed in the glass tube, a fluorescent substance clad on the inner walls of the glass tube, and a clad conducting strip extending the entire length of the glass tube in the axial direction on the inner surface of the tube.

  20. Lamps and lighting

    CERN Document Server

    Cayless, MA; Marsden, A M

    2012-01-01

    This book is a comprehensive guide to the theory and practice of lighting. Covering the physics of light production, light sources, circuits and a wide variety of lighting applications, it is both suitable as a detailed textbook and as thoroughly practical guide for practising lighting engineers. This fourth edition of Lamps and Lighting has been completely updated with new chapters on the latest lamp technology and applications. The editors ahve called upon a wide range of expertise and as a result many sections have been broadened to include both European and US practice.The book begins with

  1. The response of the radionuclide monitoring programme for agricultural products in Great Britain to the accident at Chernobyl

    International Nuclear Information System (INIS)

    Morris, J.A.

    1986-01-01

    The overall objective of the radiation monitoring and control programme of the Ministry of Agriculture, Fisheries and Food in Great Britain is to ensure the safety of foodstuffs. The particular responsibility of my department within the Ministry is the analysis of agricultural products for the presence of radionuclides entering the human food chain from atmospheric releases. The Ministry also has a laboratory which monitors the marine environment. This presentation describes the surveillance programme for agricultural foodstuffs and show how it was used to monitor the deposition from the Chernobyl accident, and shows some of the monitoring data obtained and indicate how the information was used in formulating protective measures. It also mentions future plans

  2. The response of the radionuclide monitoring programme for agricultural products in Great Britain to the accident at Chernobyl

    Energy Technology Data Exchange (ETDEWEB)

    Morris, J A [Central Veterinary Laboratory, Weybridge, Surrey (United Kingdom)

    1986-07-01

    The overall objective of the radiation monitoring and control programme of the Ministry of Agriculture, Fisheries and Food in Great Britain is to ensure the safety of foodstuffs. The particular responsibility of my department within the Ministry is the analysis of agricultural products for the presence of radionuclides entering the human food chain from atmospheric releases. The Ministry also has a laboratory which monitors the marine environment. This presentation describes the surveillance programme for agricultural foodstuffs and show how it was used to monitor the deposition from the Chernobyl accident, and shows some of the monitoring data obtained and indicate how the information was used in formulating protective measures. It also mentions future plans.

  3. Design of a Tritium-in-air-monitor using field programmable gate arrays

    International Nuclear Information System (INIS)

    McNelles, Phillip; Lu, Lixuan

    2015-01-01

    Field Programmable Gate Arrays (FPGAs) have recently garnered significant interest for certain applications within the nuclear field. Some applications of these devices include Instrumentation and Control (I and C) systems, pulse measurement systems, particle detectors and health physics purposes. In CANada Deuterium Uranium (CANDU) nuclear power plants, the use of heavy water (D2O) as the moderator leads to the increased production of Tritium, which poses a health risk and must be monitored by Tritium-In-Air Monitors (TAMs). Traditional TAMs are mostly designed using microprocessors. More recent studies show that FPGAs could be a potential alternative to implement the electronic logic used in radiation detectors, such as the TAM, more effectively. In this paper, an FPGA-based TAM is designed and constructed in a laboratory setting using an FPGA-based cRIO system. New functionalities, such as the detection of Carbon-14 and the addition of noble gas compensation are incorporated into a new FPGA-based TAM. Additionally, all of the standard functions included in the original microprocessor-based TAM, such as tritium detection, gamma compensation, pump and air flow control, and background and thermal drift corrections were also implemented. The effectiveness of the new design is demonstrated through simulations as well as laboratory testing on the prototype system. (author)

  4. Zoonoses action plan Salmonella monitoring programme: an investigation of the sampling protocol.

    Science.gov (United States)

    Snary, E L; Munday, D K; Arnold, M E; Cook, A J C

    2010-03-01

    The Zoonoses Action Plan (ZAP) Salmonella Programme was established by the British Pig Executive to monitor Salmonella prevalence in quality-assured British pigs at slaughter by testing a sample of pigs with a meat juice enzyme-linked immunosorbent assay for antibodies against group B and C(1) Salmonella. Farms were assigned a ZAP level (1 to 3) depending on the monitored prevalence, and ZAP 2 or 3 farms were required to act to reduce the prevalence. The ultimate goal was to reduce the risk of human salmonellosis attributable to British pork. A mathematical model has been developed to describe the ZAP sampling protocol. Results show that the probability of assigning a farm the correct ZAP level was high, except for farms that had a seroprevalence close to the cutoff points between different ZAP levels. Sensitivity analyses identified that the probability of assigning a farm to the correct ZAP level was dependent on the sensitivity and specificity of the test, the number of batches taken to slaughter each quarter, and the number of samples taken per batch. The variability of the predicted seroprevalence was reduced as the number of batches or samples increased and, away from the cutoff points, the probability of being assigned the correct ZAP level increased as the number of batches or samples increased. In summary, the model described here provided invaluable insight into the ZAP sampling protocol. Further work is required to understand the impact of the program for Salmonella infection in British pig farms and therefore on human health.

  5. Guide: Monitoring Programme for unannounced inspections undertaken against the National Standards for the Prevention and Control of Healthcare Associated Infections

    OpenAIRE

    2014-01-01

    This is a guide to the Health Information and Quality Authority?s (the Authority) programme of monitoring service providers? compliance with the National Standards for the Prevention and Control of Healthcare Associated Infections (referred to in this guide as the Infection, Prevention and Control Standards). This guide explains the approach that the Authority takes when monitoring the compliance of service providers ? including hospitals ? with the Infection, Prevention and Control Standards...

  6. Report of a three-year monitoring programme at Heshang Cave, Central China

    Directory of Open Access Journals (Sweden)

    Chaoyong Hu

    2008-10-01

    Full Text Available Heshang Cave is situated in central China (30º27’N, 110º25’E; 294 m in the middle reaches of the Yangtze Valley, a region stronglyimpacted by the East Asian Monsoon. It contains large annually-laminated Holocene and late Pleistocene stalagmites which capture pastmonsoon behaviour with seasonal resolution, and could enhance understanding of the amplitude and frequency of monsoon behaviour indifferent climate states. In this paper, we present results of a 3-year monitoring programme at Heshang. T loggers outside the cave agree closely with T data from nearby meteorological stations. T at the site of growth of the largest recovered stalagmite averages 18ºC (identical to mean annual T outside the cave with a seasonal amplitude of 5ºC (about one fifth of the external cycle. Rainfall measurements from a station 3 km from the cave indicate strong summer monsoon rain in 2004 and 2005, but rather weaker summer rain (by ≈30% in 2006.Drip rate at the monitoring site has a base flow of 14 drips/minute and shows a sharp increase to ≈40 drips/minute early in the summerrains of 2004 and 2005, followed by a gradual return to base-flow as the monsoon weakens. This abrupt change presumably representsthreshold behaviour in the hydrological system. This threshold is not passed in 2006 and there is no abrupt increase in drip rate, indicating the sensitivity of this site (and presumably of speleothem chemistry in this cave to monsoon rainfall. Results are also reported from a 10-month deployment of a Stalagmate drip counter, and for CO2 levels in Heshang Cave. Overall, this monitoring work represents an essential dataset for interpretation of the chemistry of drip waters, of carbonates grown on glass slides and, ultimately, of long speleothem records of past climate from Heshang Cave.

  7. Terrestrial radioactivity monitoring programme (TRAMP) report for 1994. Radioactivity in food and agricultural products in England and Wales

    International Nuclear Information System (INIS)

    1995-01-01

    The Ministry of Agriculture and Fisheries monitoring programmes for radioactivity in the terrestrial environment of the United Kingdom during 1994 are described. The results of the analyses performed with a commentary are presented. Two complimentary programmes, TRAMP and FARM, are used to ensure that radiation doses received by the public from the consumption of foodstuffs are controlled ion accordance with national and international guidelines. TRAMP concentrates on the monitoring of agricultural produce from the vicinity of the 23 licensed nuclear sites in England and Wales. The focus of FARM is the safety of the general food supply through natural food monitoring; a representative selection of industrial and landfill sites which provide potential sources of radionuclide contamination of the food chain is also monitored. In addition, monitoring programmes are undertaken for airborne grass and soil contamination in the neighbourhood of 18 nuclear sites. The overall conclusion drawn from the results presented is that public exposure to anthropogenic radioactivity due to the consumption of milk and foodstuffs grown around licensed nuclear sites in 1994 was well within acceptable limits. (67 references; 97 tables). (UK)

  8. Linked symptom monitoring and depression treatment programmes for specialist cancer services: protocol for a mixed-methods implementation study

    Science.gov (United States)

    Walker, Jane; Burke, Katy; Sevdalis, Nick; Richardson, Alison; Mulick, Amy; Frost, Chris; Sharpe, Michael

    2017-01-01

    Introduction There is growing awareness that cancer services need to address patients’ well-being as well as treating their cancer. We developed systematic approaches to (1) monitoring patients’ symptoms including depression using a ‘Symptom Monitoring Service’ and (2) providing treatment for those with major depression using a programme called ‘Depression Care for People with Cancer’. Used together, these two programmes were found to be highly effective and cost-effective in clinical trials. The overall aims of this project are to: (1) study the process of introducing these programmes into routine clinical care in a large cancer service, (2) identify the challenges associated with implementation and how these are overcome, (3) determine their effectiveness in a routine non-research setting and (4) describe patients’ and clinicians’ experience of the programmes. Methods and analysis This is a mixed-methods longitudinal implementation study. We will study the process of implementation in three phases (April 2016–December 2018): ‘Pre-implementation’ (setting up of the new programmes), ‘Early Implementation’ (implementation of the programmes in a small number of clinics) and ‘Implementation and Maintenance’ (implementation in the majority of clinics). We will use the following methods of data collection: (1) contemporaneous logs of the implementation process, (2) interviews with healthcare professionals and managers, (3) interviews with patients and (4) routinely collected clinical data. Ethics and dissemination The study has been reviewed by a joint committee of Oxford University Hospitals National Health Service Foundation Trust Research and Development Department and the University of Oxford’s Clinical Trials and Research Governance Department and judged to be service evaluation, not requiring ethics committee approval. The findings of this study will guide the scaling up implementation of the programmes across the UK and will enable

  9. Linked symptom monitoring and depression treatment programmes for specialist cancer services: protocol for a mixed-methods implementation study.

    Science.gov (United States)

    Wanat, Marta; Walker, Jane; Burke, Katy; Sevdalis, Nick; Richardson, Alison; Mulick, Amy; Frost, Chris; Sharpe, Michael

    2017-07-02

    There is growing awareness that cancer services need to address patients' well-being as well as treating their cancer. We developed systematic approaches to (1) monitoring patients' symptoms including depression using a 'Symptom Monitoring Service' and (2) providing treatment for those with major depression using a programme called 'Depression Care for People with Cancer'. Used together, these two programmes were found to be highly effective and cost-effective in clinical trials. The overall aims of this project are to: (1) study the process of introducing these programmes into routine clinical care in a large cancer service, (2) identify the challenges associated with implementation and how these are overcome, (3) determine their effectiveness in a routine non-research setting and (4) describe patients' and clinicians' experience of the programmes. This is a mixed-methods longitudinal implementation study. We will study the process of implementation in three phases (April 2016-December 2018): 'Pre-implementation' (setting up of the new programmes), 'Early Implementation' (implementation of the programmes in a small number of clinics) and 'Implementation and Maintenance' (implementation in the majority of clinics). We will use the following methods of data collection: (1) contemporaneous logs of the implementation process, (2) interviews with healthcare professionals and managers, (3) interviews with patients and (4) routinely collected clinical data. The study has been reviewed by a joint committee of Oxford University Hospitals National Health Service Foundation Trust Research and Development Department and the University of Oxford's Clinical Trials and Research Governance Department and judged to be service evaluation, not requiring ethics committee approval. The findings of this study will guide the scaling up implementation of the programmes across the UK and will enable us to construct an implementation toolkit. We will disseminate our findings in

  10. Monitoring of long-range transported air pollutants and precipitation. Monitoring programme for forest damage. Abstract of annual reports 1996; Overvaaking av langtransportert forurenset luft og nedboer. Overvaakingsprogram for skogskader. Sammendrag av aarsrapporter 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    This report sums up the results for 1996 of two monitoring programmes: `` Norwegian Monitoring Programme for Long-Range Transported Air Pollutants`` and ``Norwegian forest monitoring programme``. The atmospheric pollution is monitored by measurements of chemical main components in the air and in precipitation. The effects of the pollutants on water quality are followed by monitoring of rivers, lakes and field research areas. The effects on fish are followed by regional investigations on benthic organisms, zooplankton and fish populations in rivers and lakes. Water chemical samples are taken each month from 16 rivers and acid material is monitored at seven field research areas. Samples are also taken from 200 lakes every autumn. The biological monitoring programme comprises fish in lakes and streams and benthic animals in lakes. The monitoring of forest damage uses three nation-wide areas from which registrations have been taken over a period of ten years. 28 figs., 6 tabs.

  11. Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET

    International Nuclear Information System (INIS)

    Boellaard, R.; Lingen, A. van; Balen, S.C.M. van; Hoving, B.G.; Lammertsma, A.A.

    2001-01-01

    The first performance tests of a new fully programmable blood sampling device for monitoring blood radioactivity during positron emission tomography (PET) are described. Blood is withdrawn through 1-mm internal diameter tubing using an infusion pump which can be operated at rates varying from 0 to 600 ml/h. Activity in blood is measured by a 6-cm-thick bismuth germanate crystal connected to a photomultiplier tube and multichannel analyser (MCA) which are positioned within 6 cm lead shielding. Positioning of the tubing is an exact and simple procedure. The minimal readout time of the MCA is 1 s. Two independent energy windows can be set. Operation of the pump and MCA is fully controlled by a PC, i.e. sampling time, interval time and pump rate can be varied at any time during the PET scan by user-defined scripts. A number of characteristics of the new system were studied, such as sensitivity, dead time, linearity, effect of background radiation and pump rate as a function of input pressure. In addition, dispersion was measured as a function of pump rate. Finally, first clinical results were compared with manual samples. The sensitivity equalled 0.7 and 0.2 cps/Bq for 511- and 1022-keV 30% energy windows, respectively, and the system dead time was 500 ns. The system remained linear within 2% with activity concentrations up to 2.5 MBq/cc. Short-term reproducibility was better than 3% for a 1-h period. Long-term reproducibility was about 5% (1SD), which was mainly caused by variation in the diameter of the tubing. If the device was positioned in such a way that maximum shielding was directed towards the patient, the effects of background radiation from the patient on the measured activity concentration for clinically relevant conditions was minimal ( -1 were observed for pump rates higher than 300 ml/h, indicating that the system dispersion is small. Clinical data showed an excellent agreement to within 3% (1SD) between the results obtained with the new system and

  12. Elsam. Offshore Wind Farm. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2001 - 31. December 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-15

    As a result of the Danish Government's Energy Plan 21 a target of 5,500 MW wind power is to be erected in Denmark by 2030. 4,000 MW of these are to be placed offshore in special pointed areas with minimal impacts on the environment. In 1998 the Danish Ministry of Environment and Energy ordered two power companies, Elsam and Energi E2, to establish each a demonstration wind farm at one of the five pointed areas. The intention was to follow the environmental impacts from the wind farm and to evaluate the possibility of setting up about 1,500 MW in each area with as little impact on the environment as possible. In 1999 the two power companies were given approval to begin pre-studies of each of the two wind farms and the work on the site construction as well as the environmental impact assessment related hereto was initiated. The authorities made a number of requirements for the EIA surveys according to the EU-directive for preparation of EIA reports. In the summer of 2000 the EIA report with project description was submitted to the authorities and the project was approved in the spring of 2001. During the summer and autumn of 2001 orders were placed for the components for the wind farm, i.e. foundations, towers, wind turbines, cables etc. After having finalised the EIA, monitoring programmes of the wind farms were initiated on basis of the results of the surveys carried out during the EIA. This means that continuous surveys have been implemented for most of the environmental parameters from 1999 and till today. This annual status report for 2001 is to present the results from the annual environmental monitoring programme (the baseline studies) at Horns Rev, which form part of the monitoring programme set up for the Horns Rev project. To get a complete picture of the Danish monitoring programme for the national demonstration wind farm project it is necessary to see the report for Horns Rev and for Roedsand as a whole. The report comprises a description of the wind

  13. Elsam. Offshore Wind Farm. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2001 - 31. December 2001

    International Nuclear Information System (INIS)

    2002-10-01

    As a result of the Danish Government's Energy Plan 21 a target of 5,500 MW wind power is to be erected in Denmark by 2030. 4,000 MW of these are to be placed offshore in special pointed areas with minimal impacts on the environment. In 1998 the Danish Ministry of Environment and Energy ordered two power companies, Elsam and Energi E2, to establish each a demonstration wind farm at one of the five pointed areas. The intention was to follow the environmental impacts from the wind farm and to evaluate the possibility of setting up about 1,500 MW in each area with as little impact on the environment as possible. In 1999 the two power companies were given approval to begin pre-studies of each of the two wind farms and the work on the site construction as well as the environmental impact assessment related hereto was initiated. The authorities made a number of requirements for the EIA surveys according to the EU-directive for preparation of EIA reports. In the summer of 2000 the EIA report with project description was submitted to the authorities and the project was approved in the spring of 2001. During the summer and autumn of 2001 orders were placed for the components for the wind farm, i.e. foundations, towers, wind turbines, cables etc. After having finalised the EIA, monitoring programmes of the wind farms were initiated on basis of the results of the surveys carried out during the EIA. This means that continuous surveys have been implemented for most of the environmental parameters from 1999 and till today. This annual status report for 2001 is to present the results from the annual environmental monitoring programme (the baseline studies) at Horns Rev, which form part of the monitoring programme set up for the Horns Rev project. To get a complete picture of the Danish monitoring programme for the national demonstration wind farm project it is necessary to see the report for Horns Rev and for Roedsand as a whole. The report comprises a description of the wind farm

  14. Inductive tuners for microwave driven discharge lamps

    Science.gov (United States)

    Simpson, James E.

    1999-01-01

    An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

  15. Radioactivity in the environment. A summary and radiological assessment of the Environment Agency's monitoring programmes; report for 1997

    International Nuclear Information System (INIS)

    1997-01-01

    The Radioactive Substances Act 1993 provides for controls to be exercised over the keeping and use of radioactive materials and, in particular, on the accumulation and disposal of radioactive wastes. The Environment Agency is responsible for administration and enforcement of the Act in England and Wales. In support of these regulatory functions and as part of the UK Government's arrangements for providing information to the European Commission under the Euratom Treaty, the Agency commissions independent monitoring of radioactive waste disposals and their impact on the environment, and monitoring of radioactivity in air, rainwater and drinking water sources. This report presents the data from these monitoring programmes and provides a commentary on their radiological significance. It includes assessments of radiation exposure of members of the public for compliance with the annual dose limit recommended by the International Commission on Radiological Protection. Concentrations of radioactivity in water are also assessed in relation to the guidelines on drinking water quality recommended by the World Health Organisation. This report for 1997 is one of an annual series published by the Agency. It is being distributed to local authorities as part of the arrangements under the Radioactive Substances Act 1993 for provision of access to environmental information. The monitoring programmes and preparation of this report are managed by the Agency's National Compliance Assessment Service. (author)

  16. Radioactivity in the environment. A summary and radiological assessment of the Environment Ageny's monitoring programmes. Report for 1996

    International Nuclear Information System (INIS)

    1996-01-01

    This report presents the results from the Environment Agency's monitoring of radioactivity in the environment during 1996. Monitoring programmes were carried out in support of the Agency's regulatory functions under the Radioactive Substances Act 1993 and as part of the UK Government's obligations under the Euratom Treaty. The programmes included: effluent monitoring; the quality checking of solid waste disposals; environmental monitoring; the monitoring of radioactivity in air and rainwater; the monitoring of radioactivity in drinking water sources. A total of 160 effluent samples were analysed for nearly 900 determinants, two consignments of solid radioactive waste destined for disposal at British Nuclear Fuels' site at Drigg were checked, direct instrumental monitoring was carried out at ISO locations within the vicinity of nuclear sites, and 532 environmental samples were analysed for over 2,000 determinants. Effluent monitoring: The Agency requires operators of certain sites to provide samples of their liquid effluents for independent analysis. The results are compared with reports submitted by site operators. The majority of results showed satisfactory agreement; operators' values were frequently higher than the Agency's measurements indicating that they were not under-reporting. However, some discrepancies were found and are being investigated. Quality checking of solid waste disposals: Consignments of solid low level radioactive waste are seized by inspectors for examination at the Agency's Waste Quality Checking Laboratory. Sophisticated non-destructive and destructive analytical techniques are used at the laboratory to check the radioactive content and description of the wastes. Consignments of waste from the Atomic Weapons Establishment at Aldermaston and Amersham International at Amersham were examined. In both cases the operators reported higher activity than the Agency's laboratory. The consignments also conformed with the operators' disposal

  17. Long-term monitoring programme of the hydrological variability in the Mediterranean Sea: a first overview of the HYDROCHANGES network

    Directory of Open Access Journals (Sweden)

    K. Schroeder

    2013-03-01

    Full Text Available The long-term monitoring of basic hydrological parameters (temperature and salinity, collected as time series with adequate temporal resolution (i.e. with a sampling interval allowing the resolution of all important timescales in key places of the Mediterranean Sea (straits and channels, zones of dense water formation, deep parts of the basins, constitute a priority in the context of global changes. This led CIESM (The Mediterranean Science Commission to support, since 2002, the HYDROCHANGES programme (http//www.ciesm.org/marine/programs/hydrochanges.htm, a network of autonomous conductivity, temperature, and depth (CTD sensors, deployed on mainly short and easily manageable subsurface moorings, within the core of a certain water mass. The HYDROCHANGES strategy is twofold and develops on different scales. To get information about long-term changes of hydrological characteristics, long time series are needed. But before these series are long enough they allow the detection of links between them at shorter timescales that may provide extremely valuable information about the functioning of the Mediterranean Sea. The aim of this paper is to present the history of the programme and the current set-up of the network (monitored sites, involved groups as well as to provide for the first time an overview of all the time series collected under the HYDROCHANGES umbrella, discussing the results obtained thanks to the programme.

  18. FAO UN-REDD- INPE Joint Programme on Forest Monitoring Systems based on RS and GIS techniques

    Science.gov (United States)

    Jonckheere, I. G.; FAO UN-REDD MRV Team

    2010-12-01

    Capacity Development and Training for National Forest Monitoring Systems for Reducing Emissions from Deforestation and Forest Degradation in Developing Countries (REDD+) REDD+, which stands for ’Reducing Emissions from Deforestation and Forest Degradation in Developing Countries’ - is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. The UN-REDD Programme, a collaborative partnership between FAO, UNDP and UNEP launched in September 2008, supports countries to develop capacity to REDD+ and to implement a future REDD+ mechanism in a post-2012 climate regime. The programme works at both the national and global scale, through support mechanisms for country-driven REDD strategies and international consensus-building on REDD+ processes. The UN-REDD Programme gathers technical teams from around the world to develop common approaches, analyses and guidelines on issues such as measurement, reporting and verification (MRV) of carbon emissions and flows, remote sensing, and greenhouse gas inventories. Within the partnership, FAO supports countries on technical issues related to forestry and the development of cost effective and credible MRV processes for emission reductions. While at the international level, it fosters improved guidance on MRV approaches, including consensus on principles and guidelines for MRV and training programmes. It provides guidance on how best to design and implement REDD+, to ensure that forests continue to provide multiple benefits for livelihoods and biodiversity to societies while storing carbon at the same time. Other areas of work include national forest assessments and monitoring of in-country policy and institutional change. FAO and INPE (Brazilian Space Agency) have joint forces through a MoU signed last year in Copenhagen. A major joint programme has been agreed upon to set

  19. Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The lumen depreciation and color shift of 38 different lamps (32 LED, 2 CFL, 1 ceramic metal halide [CMH], 3 halogen) were monitored in a specially developed automated long-term test apparatus (ALTA2) for nearly 14,000 hours. Five samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at a target ambient temperature between 44°C and 45°C.

  20. Key indicators for the monitoring and evaluation of control programmes of human African trypanosomiasis due to Trypanosoma brucei gambiense.

    Science.gov (United States)

    Bouchet, B; Legros, D; Lee, E

    1998-06-01

    Very little research has been devoted to the design of epidemiological tools for the monitoring and evaluation of National Human African Trypanosomiasis (HAT) Control Programmes and daily management decisions are made in the absence of accurate knowledge of the situation. This paper identifies key indicators necessary to make decisions in the field and constantly adjust control activities to changing situations. Examples are derived from the Médecins Sans Frontières (MSF) HAT Control Programme in Adjumani, Uganda. Based on the principles of quality assurance, the focus is placed on process indicators. A conceptual framework derived from a system view/planning cycle perspective is also described for the construction of indicators. Finally, some specific challenging aspects of the epidemiology of HAT are presented and the limitations of the interpretation of the indicators discussed.

  1. Final report on the Risoe monitoring programme after the Chernobyl accident for the period Oct 1, 1986 - Sept 30, 1987

    International Nuclear Information System (INIS)

    Aarkrog, A.; Nielsen, S.P.; Dahlgaard, H.; Lauridsen, B.; Soegaard-Hansen, J.

    1988-01-01

    In cooperation with the National Agency of Environmental Protection in Denmark, Risoe National Laboratory has examined the radioactive contamination from the Chernobyl accident. The programme for these investigations was an expansion of the countrywide monitoring programme operated since 1962 by Risoe National Laboratory. The present report cover the period Oct 1, 1986 to Sept. 30, 1987. All types of environmental samples relevant for radioactive contamination has been analysed. Most samples were collected countrywide and all samples were analysed for radiocaesium ( 134 Cs and 137 Cs). Many samples were furthermore anlaysed for 90 Sr and in a few samples transuranic elements ( 29,240 Pu, 241 Am and 242 Cm) were determined. On the basis of the diet and wholebody measurements of radiocaesium the individual mean dose equivalent commitment from Danish diet consumed in the first two years after the Chernobyl accident was calculated to 27 μ Sv. (author)

  2. Field application of smart SHM using field programmable gate array technology to monitor an RC bridge in New Mexico

    International Nuclear Information System (INIS)

    Azarbayejani, M; Jalalpour, M; Reda Taha, M M; El-Osery, A I

    2011-01-01

    In this paper, an innovative field application of a structural health monitoring (SHM) system using field programmable gate array (FPGA) technology and wireless communication is presented. The new SHM system was installed to monitor a reinforced concrete (RC) bridge on Interstate 40 (I-40) in Tucumcari, New Mexico. This newly installed system allows continuous remote monitoring of this bridge using solar power. Details of the SHM component design and installation are discussed. The integration of FPGA and solar power technologies make it possible to remotely monitor infrastructure with limited access to power. Furthermore, the use of FPGA technology enables smart monitoring where data communication takes place on-need (when damage warning signs are met) and on-demand for periodic monitoring of the bridge. Such a system enables a significant cut in communication cost and power demands which are two challenges during SHM operation. Finally, a three-dimensional finite element (FE) model of the bridge was developed and calibrated using a static loading field test. This model is then used for simulating damage occurrence on the bridge. Using the proposed automation process for SHM will reduce human intervention significantly and can save millions of dollars currently spent on prescheduled inspection of critical infrastructure worldwide

  3. Field application of smart SHM using field programmable gate array technology to monitor an RC bridge in New Mexico

    Science.gov (United States)

    Azarbayejani, M.; Jalalpour, M.; El-Osery, A. I.; Reda Taha, M. M.

    2011-08-01

    In this paper, an innovative field application of a structural health monitoring (SHM) system using field programmable gate array (FPGA) technology and wireless communication is presented. The new SHM system was installed to monitor a reinforced concrete (RC) bridge on Interstate 40 (I-40) in Tucumcari, New Mexico. This newly installed system allows continuous remote monitoring of this bridge using solar power. Details of the SHM component design and installation are discussed. The integration of FPGA and solar power technologies make it possible to remotely monitor infrastructure with limited access to power. Furthermore, the use of FPGA technology enables smart monitoring where data communication takes place on-need (when damage warning signs are met) and on-demand for periodic monitoring of the bridge. Such a system enables a significant cut in communication cost and power demands which are two challenges during SHM operation. Finally, a three-dimensional finite element (FE) model of the bridge was developed and calibrated using a static loading field test. This model is then used for simulating damage occurrence on the bridge. Using the proposed automation process for SHM will reduce human intervention significantly and can save millions of dollars currently spent on prescheduled inspection of critical infrastructure worldwide.

  4. For the verification of National Biodigester Programme Cambodia. Monitoring period I (24/5/2009 - 31/08/2010)

    Energy Technology Data Exchange (ETDEWEB)

    Buysman, E.

    2011-11-15

    The National Biodigester Programme (NBP) Cambodia has executed a monitoring survey for her Voluntary Gold Standard (VGS) project. The VGS project is located in South-East Cambodia and covers 8 provinces. The monitoring activities are executed according to the monitoring plan in the PDD and the Gold Standard Passport, both document are approved by the DOE. The monitoring period I runs from 24-5-2009 to 31-08-2010. The survey population is 8571 biodigesters built as of 31-08-2010. The survey strategy is a stratified sampling approach, where first 12 districts were randomly selected and 120 households were randomly selected of the survey population in these 12 districts. The survey sample of 120 households is based on a confidence interval of 95% and a sampling error of 10%. The survey sample is twice as high as dictated by the used methodology in the PDD. The main findings of the monitoring survey are: (1) The project has an annual per household project emission of 0.512 tCO2 from physical leakage, incomplete combustion and wood fuel for thermal energy; (2) All the biodigester surveyed were in operation, a figure of 99% is adopted to be on the safe side; (3) The annual per household emission reductions are 4.18 tCO2; (4) The total emission reduction for the monitoring period I are 34,112 tCO2.

  5. Transparent ceramic lamp envelope materials

    Energy Technology Data Exchange (ETDEWEB)

    Wei, G C [OSRAM SYLVANIA, 71 Cherry Hill Drive, Beverly, MA 01915 (United States)

    2005-09-07

    Transparent ceramic materials with optical qualities comparable to single crystals of similar compositions have been developed in recent years, as a result of the improved understanding of powder-processing-fabrication- sintering-property inter-relationships. These high-temperature materials with a range of thermal and mechanical properties are candidate envelopes for focused-beam, short-arc lamps containing various fills operating at temperatures higher than quartz. This paper reviews the composition, structure and properties of transparent ceramic lamp envelope materials including sapphire, small-grained polycrystalline alumina, aluminium oxynitride, yttrium aluminate garnet, magnesium aluminate spinel and yttria-lanthana. A satisfactory thermal shock resistance is required for the ceramic tube to withstand the rapid heating and cooling cycles encountered in lamps. Thermophysical properties, along with the geometry, size and thickness of a transparent ceramic tube, are important parameters in the assessment of its resistance to fracture arising from thermal stresses in lamps during service. The corrosive nature of lamp-fill liquid and vapour at high temperatures requires that all lamp components be carefully chosen to meet the target life. The wide range of new transparent ceramics represents flexibility in pushing the limit of envelope materials for improved beamer lamps.

  6. Impact of the application of criteria of internal monitoring in radiological protection programmes in nuclear medicine services

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Juliao, L.Q.C.; Lourenco, M.C.; Melo, D.R.

    2005-01-01

    The manipulation of open sources in Nuclear Medicine services involves risks of external exposure and internal contamination. The radiological protection plan of facilities licensed by CNEN - Brazilian Nuclear Energy Commission - must include the evaluation of such risks and propose a programme of individual monitoring to control exposure and ensure the maintenance of conditions of radiation safety. The IAEA - International Atomic Energy Agency - recommendations presented in the Safety Guide RS-G-1.2 suggest that an internal worker monitoring program be implemented where there is a possibility of internal contamination lead to effective dose committed annual values equal to or greater than 1 mSv. This paper presents the application of such criteria to the radionuclides most frequently used in the field of Nuclear Medicine, taking into account the normal conditions of handling and the ranges of activity authorized by CNEN. It is concluded that iodine 131 manipulation for therapeutic purposes is the practice that presented the greatest risk of internal exposure of workers, requiring the adoption of a programme of internal monitoring of Nuclear Medicine services

  7. A new programme for monitoring the mass loss of the Greenland ice sheet

    DEFF Research Database (Denmark)

    Ahlstrøm, Andreas P.; Gravesen, Peter; Bech Andersen, Signe

    2008-01-01

    ). The Arctic region as a whole is warming up much more rapidly than the globe at large (ACIA 2005) and it is desirable to quantify these changes in order to provide the decision-makers with a firm knowledge base. To cover this need, the Danish Ministry of Climate and Energy has now launched a new Programme...

  8. Comprehensive monitoring system - essential tool to show the results of the energy audit and voluntary agreement programmes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    Without visible results political support to an energy efficiency programme will dissolve in a few years. Therefore high-quality monitoring and reporting systems are essential to maintain a long-term commitment. Both in Finnish Energy Audit Programme (EAP), began in 1992, and in Voluntary Agreement Scheme (VA), began in 1997, bottom-up monitoring systems have been in place almost since the beginning. These policy measures and their monitoring systems are integrated. For the EAP monitoring system data is collected in three phases: subsidies granted; the energy auditing volumes in different sectors submitted EA reports; proposed measures and saving potentials. VA annual reporting; status of implementation of the proposed measures in EA reports and implementing rate for saving potentials. In VA scheme the companies and communities report annually on their energy consumption and on energy efficiency measures they have implemented or have decided to implement. Information on energy savings in energy units and energy costs as well as the required investment is reported in connection to the presented measures. The collected data is based on engineering calculations by the energy auditors. Since the companies have no incentives to submit exaggerated savings, the reported savings are equal to those figures the companies have used as criteria when deciding on the implementation of the measures. By 2005 these two policy measures have generated about 7 TWh annual savings, representing over 2 % of Finland's total energy end-use. In relation to the magnitude of savings brought in daylight, the investment on monitoring has really paid back.

  9. Phase out of incandescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Since early 2007 almost all OECD and many non-OECD governments have announced policies aimed at phasing-out incandescent lighting within their jurisdictions. This study considers the implications of these policy developments in terms of demand for regulatory compliant lamps and the capacity and motivation of the lamp industry to produce efficient lighting products in sufficient volume to meet future demand. To assess these issues, it reviews the historic international screw-based lamp market, describes the status of international phase-out policies and presents projections of anticipated market responses to regulatory requirements to determine future demand for CFLs.

  10. Anu Lamp / [vestelnud Kalju Orro

    Index Scriptorium Estoniae

    Lamp, Anu, 1958-

    2007-01-01

    Lavakunstikooli sisseastumisest, õppimisest, õpetajatest ja õpetamisest. Anu Lamp õppis Lavakunstikoolis 10. lennus (1978-1982). Osalenud samas lavakõne õppejõuna 18.-23. lennu ja erialaõppejõuna 20. lennu töös

  11. Groundwater monitoring programme. A guide for groundwater sampling and analysis. 2. ed.; Grundwasserueberwachungsprogramm. Leitfaden fuer Probenahme und Analytik von Grundwasser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Quality assurance guidelines have been developed and introduced in Baden-Wuerttemberg for groundwater monitoring. The contribution contains the fundamentals and technical guides for sampling and measurement of the Baden-Wuerttemberg groundwater monitoring programme, as well as parameter groups and a preliminary assessment of the methods. [German] Bei der Gewinnung von Umweltdaten sind hohe Anforderungen an die Qualitaet der erhobenen Daten zu stellen. Dies trifft in besonderem Masse gerade auch fuer Grundwasseruntersuchungen zu, da hier haeufig Konzentrationen im Bereich der Nachweisgrenze auftreten. Fuer das Grundwassermessnetz Baden-Wuerttemberg sind qualitaetssichernde Regelungen entwickelt und eingefuehrt worden. In der vorliegenden Zusammenstellung sind die Grundsatzpapiere, bzw. Technischen Anleitungen aus dem Grundwasserueberwachungsprogramm Baden-Wuerttemberg fuer die Grundwasserprobennahme sowie zu Messverfahren, Parametergruppen und zur ersten Beurteilung der Messergebnisse enthalten. (orig.)

  12. Building an industry-wide occupational exposure database for respirable mineral dust - experiences from the IMA dust monitoring programme

    International Nuclear Information System (INIS)

    Houba, Remko; Jongen, Richard; Vlaanderen, Jelle; Kromhout, Hans

    2009-01-01

    Building an industry-wide database with exposure measurements of respirable mineral dust is a challenging operation. The Industrial Minerals Association (IMA-Europe) took the initiative to create an exposure database filled with data from a prospective and ongoing dust monitoring programme that was launched in 2000. More than 20 industrial mineral companies have been collecting exposure data following a common protocol since then. Recently in 2007 ArboUnie and IRAS evaluated the quality of the collected exposure data for data collected up to winter 2005/2006. The data evaluated was collected in 11 sampling campaigns by 24 companies at 84 different worksites and considered about 8,500 respirable dust measurements and 7,500 respirable crystalline silica. In the quality assurance exercise four criteria were used to evaluate the existing measurement data: personal exposure measurements, unique worker identity, sampling duration not longer than one shift and availability of a limit of detection. Review of existing exposure data in the IMA dust monitoring programme database showed that 58% of collected respirable dust measurements and 62% of collected respirable quartz could be regarded as 'good quality data' meeting the four criteria mentioned above. Only one third of the measurement data included repeated measurements (within a sampling campaign) that would allow advanced statistical analysis incorporating estimates of within- and between-worker variability in exposure to respirable mineral dust. This data came from 7 companies comprising measurements from 23 sites. Problematic data was collected in some specific countries and to a large extent this was due to local practices and legislation (e.g. allowing 40-h time weighted averages). It was concluded that the potential of this unique industry-wide exposure database is very high, but that considerable improvements can be made. At the end of 2006 relatively small but essential changes were made in the dust monitoring

  13. Lot quality assurance sampling for monitoring immunization programmes: cost-efficient or quick and dirty?

    Science.gov (United States)

    Sandiford, P

    1993-09-01

    In recent years Lot quality assurance sampling (LQAS), a method derived from production-line industry, has been advocated as an efficient means to evaluate the coverage rates achieved by child immunization programmes. This paper examines the assumptions on which LQAS is based and the effect that these assumptions have on its utility as a management tool. It shows that the attractively low sample sizes used in LQAS are achieved at the expense of specificity unless unrealistic assumptions are made about the distribution of coverage rates amongst the immunization programmes to which the method is applied. Although it is a very sensitive test and its negative predictive value is probably high in most settings, its specificity and positive predictive value are likely to be low. The implications of these strengths and weaknesses with regard to management decision-making are discussed.

  14. Monitoring NSL. Progress of the Dutch National Air Quality Cooperation Programme (NSL). State of affairs 2012; Monitoringsrapportage NSL. Stand van zaken 2012 Nationaal Samenwerkingsprogamma Luchtkwaliteit

    Energy Technology Data Exchange (ETDEWEB)

    Van Zanten, M.C.; Wesseling, J.; Mooibroek, D.; Van Alphen, A.; Nguyen, L. [Rijksinstituut voor Volksgezondheid en Milieu RIVM, Bilthoven (Netherlands); Groot Wassink, H.; Verbeek, C. [InfoMil, Agentschap NL, Den Haag (Netherlands)

    2012-11-15

    The National Air Quality Cooperation Programme (NSL) has been created to facilitate improvements in air quality in the Netherlands and to ensure that the Netherlands meets the respective deadlines set for compliance to EU limit values for particulate matter (PM10) and nitrogen dioxide (NO2). Local, regional and national authorities work together within the framework of this programme to ensure that these goals will be met. A monitoring programme has been put in place to monitor progress and, if necessary, to enable timely modifications to the programme. The annual results of the monitoring programme have been bundled together by the Monitoring Bureau (collaboration between RIVM and the InfoMil Knowledge Centre) into the 2012 progress report [Dutch] Om de luchtkwaliteit te verbeteren is het Nationaal Samenwerkingsprogramma Luchtkwaliteit (NSL) opgezet. Hierin werken de Rijksoverheid en decentrale overheden samen om te zorgen dat Nederland overal tijdig aan de grenswaarden voor fijn stof en stikstofdioxide zal voldoen. Om de voortgang van dit verbeterprogramma te volgen en tijdig eventuele extra maatregelen te kunnen nemen, is aan het NSL een monitoringsprogramma verbonden. De uitvoering van de monitoring is neergelegd bij Bureau Monitoring, een samenwerkingsverband tussen het RIVM en Kenniscentrum InfoMil.

  15. Self-monitoring has potential for home exercise programmes in patients with haemophilia.

    Science.gov (United States)

    Goto, M; Takedani, H; Haga, N; Kubota, M; Ishiyama, M; Ito, S; Nitta, O

    2014-03-01

    Haemophiliacs who have had to keep a physically inactive lifestyle due to bleeding during childhood are likely to have little motivation for exercise. The purpose of this study is to clarify the effectiveness of the self-monitoring of home exercise for haemophiliacs. A randomized controlled trial was conducted with intervention over 8 weeks at four hospitals in Japan. Subjects included 32 male outpatients aged 26-64 years without an inhibitor who were randomly allocated to a self-monitoring group and a control group. Individual exercise guidance with physical activity for improvement of their knee functions was given to both groups. The self-monitoring materials included an activity monitor and a feedback system so that the self-monitoring group could send feedback via the Internet and cellular phone. The self-monitoring was performed by checking exercise adherence and physical activity levels, bleeding history and injection of a coagulation factor. Both groups showed significant improvements in exercise adherence (P self-efficacy (P self-monitoring group compared with those in the control group. No increase in bleeding frequency and pain scale was noted. The self-monitoring of home exercise for haemophilic patients is useful for the improvement of exercise adherence, self-efficacy and knee extension strength. © 2014 John Wiley & Sons Ltd.

  16. Model of discharge lamps with magnetic ballast

    OpenAIRE

    Molina, Julio; Sainz Sapera, Luis; Mesas García, Juan José; Bergas Jané, Joan Gabriel

    2013-01-01

    Magnetic ballast discharge lamp modeling has been extensively studied because these lamps can be an important source of harmonics. Discharge lamp models usually represent the arc voltage by a square waveform. However, this waveform can be far from actual arc voltages, which affects the accuracy of the lamp models. This paper investigates the actual arc voltage behavior of discharge lamps from laboratory measurements and proposes a novel characterization of these voltages to reformulate the co...

  17. The use of algae in monitoring discharges of radionuclides. Experiences from the 1992 and 1993 monitoring programmes at the Swedish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Snoeijs, P. [Uppsala Univ. (Sweden). Dept. of Ecological Botany; Simenstad, P. [Swedish Radiation Protection Inst., Stockholm (Sweden)

    1995-01-01

    All four Swedish nuclear power plants (Forsmark, Oskarshamn, Barsebaeck and Ringhals) use brackish water as coolant (Baltic Sea and Swedish west coast). Radionuclides are discharged together with the cooling water. The gamma spectra of monthly algal samples harvested in 1992 and 1993 close to the discharge points of these power plants were determined within the routine monitoring programmes. The main radionuclides detected in the algal samples were {sup 54}Mn, {sup 58}Co, {sup 60}Co and {sup 137}Cs. Most {sup 137}Cs in the samples from the northern Baltic Sea (Forsmark) still originated from the 1986 Chernobyl accident. Other radionuclides, notably {sup 51}Cr, {sup 65}Zn, {sup 95}Zr, {sup 95}Nb, {sup 110m}Ag, {sup 124}b, {sup 125}Sb and {sup 134}Cs, were regularly detected at s of the sites. Transfer factors from discharge to algae were generally in the order of 0.3-3 Bq kg{sup -1} per MBq discharge. For the major discharged radionuclides, significant linear relationships were in most cases found between discharges and concentrations in algal samples. Differences in transfer factors and regression coefficients were explained by location of the sampling sites and type of radionuclide. It is concluded that algal samples provide useful complements to water and sediment samples in the monitoring programmes since radionuclide concentrations are much higher in algal samples and proportional to the discharges. 21 refs, figs.

  18. Monitoring HIV Prevention Programme Outcomes among Key Populations in Kenya: Findings from a National Survey.

    Directory of Open Access Journals (Sweden)

    Parinita Bhattacharjee

    Full Text Available In preparation for the implementation of the Kenya AIDS Strategic Framework 2014/15-2018/19, the Kenya National AIDS and STI Control Programme facilitated a national polling booth survey as part of a baseline assessment of HIV-related risk behaviours among FSWs, MSM, and PWID, and their utilization of existing preventive interventions, as well as structural factors that may influence KPs' vulnerability to HIV. The survey was conducted among "key populations" (female sex workers, men who have sex with men, and people who inject drugs to understand current HIV risk and prevention behaviours, utilization of existing programmes and services, and experiences of violence. In total, 3,448 female sex workers, 1,308 men who have sex with men, and 690 people who inject drugs were randomly selected to participate in polling booth survey sessions from seven priority sites. Survey responses were aggregated and descriptive statistics derived. In general, reported condom use among all key populations was quite high with paying clients, and lower with regular, non-paying partners. Many participants reported unavailability of condoms or clean injecting equipment within the past month. Exposure to, and utilization of, existing HIV prevention services varied significantly among the groups, and was reported least commonly by female sex workers. Encouragingly, approximately three-quarters of all key population members reported receiving an HIV test in the past three months. All key population groups reported experiencing high levels of physical and sexual violence from partners/clients, and/or arrest and violence by law enforcement officials. Although some of the findings are encouraging, there is room for improvement in HIV prevention programmes and services for key populations across Kenya.

  19. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    Energy Technology Data Exchange (ETDEWEB)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E. [Instituto Tecnologico e Nuclear, Dept. de Proteccao Radiologica e Seguranca Nuclear Estrada Nacional, Sacavem (Portugal)

    2006-07-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  20. Quality assurance and quality control programme in use at the individual monitoring service of ITN-DPRSN

    International Nuclear Information System (INIS)

    Alves, J.G.; Novais, I.; Rangel, S.; Flores, E.

    2006-01-01

    The Individual Monitoring Service (I.M.S.) of the Departamento de Proteccao Radiologica e Seguranca Nuclear (D.P.R.S.N.) at the Instituto Tecnologico e Nuclear (I.T.N.) in Portugal operates a thermoluminescence dosimetry system to monitor approximately 3,000 workers for external radiation exposure on a monthly basis. The workers come from nearly 230 facilities in the medical, research and conventional industry fields of activity and almost 85% of the people monitored in 2005 are from medical facilities. The TLD system in use is based on two Harshaw 6600 automatic readers and on the Harshaw 8814 T.L. card and holder containing two detector elements of LiF:Mg,Ti (TLD-100) for the evaluation of Hp(10) and Hp(0.07). All the workers are monitored on a monthly basis using whole body dosemeters. The I.M.S. has implemented a Quality Assurance and Quality Control (Q.A./Q.C.) programme that covers all the aspects of monitoring, from the monitoring request of a customer to the final issue of a dose report. The main aspects of the Q.A./Q.C. programme implemented at the I.M.S. will be presented in this paper using fluxograms and schemes. Several issues will be addressed, e.g., administrative procedures, technical procedures, dealing with complaints, training of staff, etc. The relationship of the I.M.S. with external entities like the customer, the regulatory authority, the central dose registry, the calibration facility, suppliers, maintenance providers, etc. will be mentioned on the administrative procedures described as well as on the technical procedures where applicable. The main technical procedures will be presented in this paper and references will be made to a TLD Quality Control database internally developed and designed for the storage of important Q.C. parameters like the element correction coefficients, reader calibration factors, electronic quality control data generated on a daily basis, and the study of their evolution with time. (author)

  1. NRPA. Radioactivity in the marine environment 2008 and 2009. Results from the Norwegian national monitoring programme (RAME)

    International Nuclear Information System (INIS)

    Gaefvert, T.; Heldal, H. E.; Brungot, A. L.; Gwynn, J.; Svaeren, I.; Kolstad, A. K.; Moeller, B.; Straalberg, E.; Christensen, G. C.; Drefvelin, J.; Dowdall, M.; Lind, B.; Rudjord, A. L.

    2011-04-01

    The issue of present and potential radioactive contamination in the marine environment has received considerable attention in Norway. In the late 1980s several accidents and incidents involving nuclear-powered submarines,demonstrated that the risk of the release of radionuclides into the Barents Sea should be considered more carefully. In particular, it became evident that better documentation concerning the radioactivity levels in fish and other seafood was important for the seafood export industries. Furthermore, in the early 1990s, information concerning the dumping of nuclear waste emerged through bilateral environmental cooperation between Norway and Russia. In the years that followed, concern grew regarding the safety of military and civil nuclear installations in the northwest of Russia. This concern was associated not only with possible reactor accidents, but also with the prolonged or sudden release of radio-nuclides from radioactive waste facilities.In addition to the potential threats outlined above, radionuclides originating from nuclear weapons fallout, the Chernobyl accident and waste discharged from European reprocessing facilities have been detected in the Norwegian marine environment. In 1994 and 1995, the discharge of 99Tc from the reprocessing facility at Sellafield in the UK increased sharply, and although this discharge has been reduced, it continued at a high level up to 2003. There has been much public concern about the consequences of such kinds of release, as the radionuclides discharged to the Irish Sea are transported by ocean currents via the North Sea into the Norwegian coastal current and to the Barents Sea. In response to this concern, programmes for the monitoring of radioactivity in the marine environment have been established. Due to the economic importance of the fishing industry and its vulnerability to contamination, as well as any rumours of radioactive contamination, one of the main objectives of these programmes is to

  2. Monitoring of tsetse and trypanosomosis control programmes in south easter Uganda

    International Nuclear Information System (INIS)

    Okuna, N.M.; Magona, J.

    1997-01-01

    A total of 3035 cattle, 2733 from a tsetse infested area and 302 from a tsetse free area, were screened for trypanosomosis by the buffy coat technique (BCT). In addition, sample from the tsetse free area were analysed for the presence of trypasonome antigens by antigen ELISA (Ag-ELISA). Using the BCT, trypanosome were detected in 64 cattle from the tsetse infested are and none were detected in the animals from the tsetse free area. However, using the Ag-ELISA, 17(5.6%) of the cattle from the tsetse free area were found positive for T. brucei, one (0.3%) for T. vivax and none for T. congolense. The results indicate that the tsetse and animal trypanosomosis situation has improved markedly since the control programme started in 1990. However both tsetse and animal trypanosomosis still occur particularly in the souther zones of the control area. (author). 5 refs, 1 fig., 4 tabs

  3. Monitoring of tsetse and trypanosomosis control programmes in south easter Uganda

    Energy Technology Data Exchange (ETDEWEB)

    Okuna, N M; Magona, J [Livestock Health Research Inst. (LIRI), Tororo (Uganda)

    1997-02-01

    A total of 3035 cattle, 2733 from a tsetse infested area and 302 from a tsetse free area, were screened for trypanosomosis by the buffy coat technique (BCT). In addition, sample from the tsetse free area were analysed for the presence of trypasonome antigens by antigen ELISA (Ag-ELISA). Using the BCT, trypanosome were detected in 64 cattle from the tsetse infested are and none were detected in the animals from the tsetse free area. However, using the Ag-ELISA, 17(5.6%) of the cattle from the tsetse free area were found positive for T. brucei, one (0.3%) for T. vivax and none for T. congolense. The results indicate that the tsetse and animal trypanosomosis situation has improved markedly since the control programme started in 1990. However both tsetse and animal trypanosomosis still occur particularly in the souther zones of the control area. (author). 5 refs, 1 fig., 4 tabs.

  4. Monitoring and evaluation of corporate social responsibility programmes in South Africa

    Directory of Open Access Journals (Sweden)

    Renitha Rampersad

    2015-12-01

    Full Text Available The South African corporate sector invests millions to support community development and social programs. One of the more fundamental issues about sustainability in a business context is the fact that directors have a fiduciary duty to take into account interests of those stakeholders other than investors/shareholders. This therefore places major importance on sustainability reporting through reports on governance, economic, social and environmental performance and is increasingly being regarded as a key form of stakeholder engagement, and the most accepted formal way of communicating measured outcomes to all stakeholders. A number of methodologies may exist for the development of Corporate Social Responsibility (CSR strategies or “how-to guides” for community engagement and investment, however, it lacks development in the field of CSR Programme Evaluation. Integrated approaches to the measurement thereof are still in expanding stages of development and statistical data and/or empirical evidence is lacking at this point. Trust and relationships take time to build but are valuable assets, therefore a company must show it has listened and acted in response to stakeholder concerns, this means that ongoing communication and reporting back to stakeholders is a very important component in any engagement strategy. It is therefore important for the corporate sector to not only evaluate the effectiveness of their CSR Programmes, but also to measure the impact on both their beneficiary communities and their business and subsequently on the Return on Investment (ROI. This paper will highlight a case of the South African corporate sectors attempts to evaluate its effectiveness and impact on beneficiary communities and how they quantify the impact of the investment through successful CSR interventions.

  5. Peer monitoring, social ties and moral hazard in group lending programmes : evidence from Eritrea

    NARCIS (Netherlands)

    Hermes, C.L.M.; Lensink, B.W.; Mehrteab, H.T.

    2003-01-01

    In this paper, we provide an empirical analysis of the impact of monitoring and social ties within group lending programs on moral hazard behavior of its participants, based on data from an extensive questionnaire held in Eritrea among participants of 102 groups. We find support for the fact that

  6. Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit

    Science.gov (United States)

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations ...

  7. Monitoring programme for the MV2, Part IV : Archeological and palaeontological finds

    NARCIS (Netherlands)

    Borst, W.; Weerts, H.; Vellinga, T.; Otte, A.

    2014-01-01

    This is the fourth and last of a series of articles describing the extensive monitoring related to the construction of Maasvlakte 2, Port of Rotterdam, the Netherlands. As far back as the 1990s during the first studies by the Main Port Rotterdam (PMR) project organisation for Maasvlakte 2 (MV2),

  8. Breast cancer screening programmes: the development of a monitoring and evaluation system.

    OpenAIRE

    Day, N. E.; Williams, D. R.; Khaw, K. T.

    1989-01-01

    It is important that the introduction of breast screening is closely monitored. The anticipated effect on breast cancer mortality will take 10 years or more fully to emerge, and will only occur if a succession of more short-term end points are met. Data from the Swedish two-county randomised trial provide targets that should be achieved, following a logical progression of compliance with the initial invitation, prevalence and stage distribution at the prevalence screen, the rate of interval c...

  9. High-pressure sodium lamp

    NARCIS (Netherlands)

    1996-01-01

    A high pressure sodium lamp of the invention is provided with a discharge vessel (20) which is enclosed with intervening space (1) by an outer bulb (10), which space contains a gas-fill with at least 70 mol. % nitrogen gas. Electrodes (30a, 30b) are positioned in the discharge vessel (20) and are

  10. AC ignition of HID lamps

    NARCIS (Netherlands)

    Sobota, A.; Kanters, J.H.M.; Manders, F.; Veldhuizen, van E.M.; Haverlag, M.

    2010-01-01

    Our aim was to examine the starting behaviour of mid-pressure argon discharges in pin-pin (point-to-point) geometry, typically used in HID lamps. We focused our work on AC ignition of 300 and 700 mbar Ar discharges in Philips 70W standard burners. Frequency was varied between 200 kHz and 1 MHz. In

  11. UV lamp for photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Cardoso, M.J.B.; Landers, R.; Sundaram, V.S.

    1983-01-01

    An UV lamp and a differential pumping system which enables to couple the lamp to an ultra-high vacuum chamber (10 -9 torr) without using windows, are described. The differential between the pressure inside the discharge chamber and the one in de UHV region, which is of 10 8 -10 9 , is achieved with two pumping states separated by pyrex capillaries having an internal diameter of 0.6 mm. In the first stage, a mechanical pump (10 -3 torr) is used; in the second stage, a diffusor pump with a cryogenic trap (N 2 liq - 10 -7 torr) is employed. The lamp produces, when used with high purity He, narrow lines almost clear at 21.2 eV and 40.8 eV, depending on the discharge chamber pressure, thus eliminating the need of a monochromator. As a high voltage source (3 KV), a commercial unit with a good current control was used, ensuring UV beam stability - an essential characteristic for this lamp if it is employed for photoelectron excitation of crystalline samples. (C.L.B.) [pt

  12. 30 CFR 57.17010 - Electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...

  13. 49 CFR 234.221 - Lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be...

  14. Remote monitoring field trial. Application to automated air sampling. Report on Task FIN-E935 of the Finnish Support Programme to IAEA Safeguards

    International Nuclear Information System (INIS)

    Poellaenen, R.; Ilander, T.; Lehtinen, J.; Leppaenen, A.; Nikkinen, M.; Toivonen, H.; Ylaetalo, S.; Smartt, H.; Garcia, R.; Martinez, R.; Glidewell, D.; Krantz, K.

    1999-01-01

    An automated air sampling station has recently been developed by Radiation and Nuclear Safety Authority (STUK). The station is furnished with equipment that allows comprehensive remote monitoring of the station and the data. Under the Finnish Support Programme to IAEA Safeguards, STUK and Sandia National Laboratories (SNL) established a field trial to demonstrate the use of remote monitoring technologies. STUK provided means for real-lime radiation monitoring and sample authentication whereas SNL delivered means for authenticated surveillance of the equipment and its location. The field trial showed that remote monitoring can be carried out using simple means although advanced facilities are needed for comprehensive surveillance. Authenticated measurement data could be reliably transferred from the monitoring site to the headquarters without the presence of authorized personnel in the monitoring site. The operation of the station and the remote monitoring system were reliable. (orig.)

  15. Animal trypanosomosis: Diagnosis and epidemiology. Results of a FAO/IAEA co-ordinated research programme on the use of immunoassay methods for improved diagnosis of trypanosomosis and monitoring tsetse and trypanosomosis control programmes

    International Nuclear Information System (INIS)

    2000-01-01

    One of the tasks of the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture is to promote the use of nuclear techniques for improving disease diagnosis and monitoring disease control programmes in order to optimise animal production in developing countries. An applied research programme was initiated in 1987 with funding from the Government of the Netherlands to validate an ELISA to detect trypanosomal antigens developed by the International Laboratory for Research on Animal Diseases (ILRAD). The test was successfully validated in ten different laboratories in Africa through a Co-ordinated Research Programme (CRP) from 1987-1993 entitled ''Improving the diagnosis and control of trypanosomosis and other vector-borne diseases of African livestock using immunoassay methods''. Results indicated a reasonable, but at times variable sensitivity and specificity (published in IAEA-TECDOC-707). During an additional two-year period (1993-1995) the IAEA Department of Technical Co-operation and the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture provided support for a Regional Technical Co-operation Project (TCP) to strengthen disease diagnostic capabilities in the National Agricultural Research Systems (NARS) with a special emphasis on the diagnosis of trypanosomosis. Results of the TCP were published in IAEA-TECDOC-925 and were encouraging enough to request additional funding from the Government of the Netherlands for a five-year programme to enable application of the assay as a tool for monitoring disease control programmes in Africa. The results of the latter programme are reported in the present publication together with a number of review articles on the diagnostic and epidemiological aspects of the disease in African livestock

  16. Spectroscopy on metal-halide lamps under varying gravity conditions

    NARCIS (Netherlands)

    Flikweert, A.J.

    2008-01-01

    Worldwide, 20% of all electricity is used for lighting. For this reason, efficient lamps are economically and ecologically important. High intensity discharge (HID) lamps are efficient lamps. The most common HID lamp these days is the metal-halide (MH) lamp. MH lamps have a good colour rendering

  17. SW England seismic monitoring for the HDR geothermal programme in Cornwall 1989 to September 1991

    International Nuclear Information System (INIS)

    Walker, A.B.

    1992-01-01

    The potential for earthquakes to be triggered by fluid injected into boreholes has been recognised for 25 years and natural earthquakes in Cornwall have been reported for over 250 years. As a result, the Geothermal Steering Committee advising the Hot Dry Rock project recommended that background seismic monitoring be undertaken around the HDR experimental site at Rosemanowes. A network of seismographs was established for this purpose by the British Geological Survey (BGS) in late 1980 and has been operated continuously through September 1991. The primary aim of the network has been to provide an independent, continuous assessment of all vibrational transients in order to discriminate between those caused by the Hot Dry Rock experiments and those of natural origin or from other man-made sources. In this respect, the work provides an insurance against claims that extraneous seismic activity is related to those experiments. (author)

  18. A modified index for monitoring of radiation protection programmes with special reference to Nuclear Medicine Institute

    International Nuclear Information System (INIS)

    Gupta, M.M.; Nagaratnam, A.

    1988-01-01

    In India, the Institute of Nuclear Medicine and Allied Sciences was established with the main objective of developing radioisotopic methodologies for diagnosis, therapy, biomedical research and training. The steady progress in India's atomic energy program gave impetus to rapid growth in the application of nuclear medicine techniques at the Institute and now it is one of the largest users of unsealed radiation sources in the country. Right from the beginning adequate attention has been devoted to the radiation safety of the staff and personnel management techniques have been successfully employed to assess performance of the radiation protection staff. A significant positive correlation (p 0.02) between performance and job satisfaction of radiation protection personnel of the Institute has been demonstrated. Efforts are also directed to evolve a parameter that may throw light on the effectiveness of radiation protection staff and subsequently that may be helpful to monitor the radiation protection program of other establishments

  19. Breast cancer screening programmes: the development of a monitoring and evaluation system.

    Science.gov (United States)

    Day, N E; Williams, D R; Khaw, K T

    1989-06-01

    It is important that the introduction of breast screening is closely monitored. The anticipated effect on breast cancer mortality will take 10 years or more fully to emerge, and will only occur if a succession of more short-term end points are met. Data from the Swedish two-county randomised trial provide targets that should be achieved, following a logical progression of compliance with the initial invitation, prevalence and stage distribution at the prevalence screen, the rate of interval cancers after the initial screen, the pick-up rate and stage distribution at later screening tests, the rate of interval cancers after later tests, the absolute rate of advanced cancer and finally the breast cancer mortality rate. For evaluation purposes, historical data on stage at diagnosis is desirable; it is suggested that tumour size is probably the most relevant variable available in most cases.

  20. Field Programmable Gate Array (FPGA Respiratory Monitoring System Using a Flow Microsensor and an Accelerometer

    Directory of Open Access Journals (Sweden)

    Mellal Idir

    2017-04-01

    Full Text Available This paper describes a non-invasive system for respiratory monitoring using a Micro Electro Mechanical Systems (MEMS flow sensor and an IMU (Inertial Measurement Unit accelerometer. The designed system is intended to be wearable and used in a hospital or at home to assist people with respiratory disorders. To ensure the accuracy of our system, we proposed a calibration method based on ANN (Artificial Neural Network to compensate the temperature drift of the silicon flow sensor. The sigmoid activation functions used in the ANN model were computed with the CORDIC (COordinate Rotation DIgital Computer algorithm. This algorithm was also used to estimate the tilt angle in body position. The design was implemented on reconfigurable platform FPGA.

  1. Slit lamps and lenses: a potential source of nosocomial infections?

    Science.gov (United States)

    Sobolewska, Bianka; Buhl, Michael; Liese, Jan; Ziemssen, Focke

    2018-01-30

    The aim of the study was to evaluate the bacterial contamination level of contact surfaces on slit lamps and the grip areas of lenses. Within unannounced audits, two regions of the slit lamps (headrest and joystick), indirect ophthalmoscopy devices, and ultrasound probes were obtained with rayon-tipped swab. Non-contact lenses used for indirect fundoscopy were pressed on RODAC (Replicate Organism Detection and Counting) plates. One hundred and eighty-one surfaces were sampled. The total number of colony-forming units was assessed and bacterial species were identified. Spa-typing and antimicrobial susceptibility testing were performed from Staphylococcus aureus isolates. Among the total bacterial isolates from ophthalmological equipment (lenses: 51 of 78, slit lamps: 43 of 88, ophthalmoscopy helmets: 3 of 8, ultrasound probes: 2 of 7), coagulase-negative staphylococci (CNS) was most frequently found, followed by Micrococcus spp. (lenses vs. slit lamps: P lenses (76%) was significantly higher than that of slit lamps (54%) (P lenses from residents vs. from consultants (78% vs. 35%, P = 0.01). A total of seven different spa-types of S. aureus were isolated. No correlation was found between S. aureus contamination of different ophthalmological equipments (Spearman's rank correlation coefficient, ρ = 0.04, P = 0.75). Methicillin-resistant S. aureus was not detected. Bacterial species of the normal skin flora were isolated from the ophthalmological equipment. The bacterial contamination of the portable devices was significantly higher than that of slit lamps. Therefore, proper hygiene of the mobile instruments should be monitored in order to prevent transmission of bacteria in residents and consultants.

  2. Materials for incandescent and fluorescent lamps

    DEFF Research Database (Denmark)

    Thorsen, Knud Aage

    1996-01-01

    The article gives an overview of the materials systems used for incandescent lamps as well as a brief introduction to the systems used for fluorescent lamps. The materials used for incandescent lamps are doped tungsten used for the filaments, metals and alloys used for terminal and support posts......, lead wires and internal reflectors and screens as well as glasses for the envelope. The physics of bulbs and changes in bulbs during use are elucidated. The cost and energy savings and environmental benefits by replacement of incandescent lamps by fluorescent lamps are presented....

  3. Portable Heart Rate Detector Based on Photoplethysmography with Android Programmable Devices for Ubiquitous Health Monitoring System

    Directory of Open Access Journals (Sweden)

    Chi Kin Lao

    2013-01-01

    Full Text Available In this paper, a miniature portable heart rate detector system is implemented by modern hardware ICs and simple sensor circuit with software executable on both PC and Android platform. The biosignal is first extracted via photoplethysmography (PPG principle into electric signal. Then a microprocessor is used to covert biosignal from analog to digital format, suitably for feeding into an RF module (nRF24L01 for RF transmission. On the receiver end, the computer and/or smart phone can analyze the data using a robust algorithm that can detect peaks of the PPG waveform, hence to calculating the heart rate. Some application software running on Windows and Android phone have been developed to display heart rate information and time domain waveform to users for health care monitoring. In the future, pure Bluetooth technology will be used for wireless personal communications instead of RF modules. At the same time, the data can be sent to computer console using existing available networks (3G, 4G, WiFi, etc. for health database logging purpose.

  4. 7th annual report 1998. UN ECE convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. [eds.

    1998-11-01

    The Integrated Monitoring Programme (ICP IM) is part of the Effects Monitoring Strategy under the UN ECE Long-Range Transboundary Air Pollution Convention. The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in the external environment. The monitoring and prediction of complex ecosystem effects on undisturbed reference areas require a continuous effort to improve the collection and assessment of data on the international scale. At the 1997 Task Force meeting it was decided that future annual reports from ICP IM would have a more technical character. The report could include some scientific material but also short technical descriptions of recent national activities and publications. Scientific articles should preferably be published in recognised scientific journals. The responsibility for producing annual reports would still lie on the Programme Centre, but more contributions from National Focal Points were welcomed. The content of the present Annual Report reflects the decisions of the Task Force meeting. The report gives a general overview of the ICP IM activities, the present content of the ICP IM database, and presents results from assessment activities carried out by several collaborating institutes and the ICP IM Programme Centre during the programme year 1997/98. The resources of the Programme Centre have been targeted to the revision of the Programme Manual and the EU/LIFE-project `Development of Assessment and Monitoring Techniques at Integrated Monitoring Sites in Europe`, which has limited the possibilities to carry out additional evaluations of ICP IM data. Section 1 is a short status report of the ICP IM activities, content of the IM database, including the contents of the GIS database, and the present geographical coverage of the monitoring network. Section 2 contains a report on multivariate gradient analysis applied to relate chemical and biological observations (prepared by D. de Zwart, RIVM

  5. Persistent quality of life impairments in differentiated thyroid cancer patients: results from a monitoring programme

    Energy Technology Data Exchange (ETDEWEB)

    Gamper, Eva-Maria [Medical University Innsbruck, Department for Nuclear Medicine, Innsbruck (Austria); Medical University Innsbruck, Department for Psychiatry and Psychotherapy, Innsbruck (Austria); Wintner, Lisa M.; Holzner, Bernhard [Medical University Innsbruck, Department for Psychiatry and Psychotherapy, Innsbruck (Austria); Rodrigues, Margarida; Buxbaum, Sabine; Nilica, Bernhard; Virgolini, Irene [Medical University Innsbruck, Department for Nuclear Medicine, Innsbruck (Austria); Singer, Susanne [University of Mainz, Institute of Medical Biostatistics, Epidemiology, and Informatics, Mainz (Germany); Giesinger, Johannes M. [Netherlands Cancer Institute, Amsterdam (Netherlands)

    2015-07-15

    Health-related quality of life (HRQOL) in differentiated thyroid cancer (DTC) research has so far received little attention and available results are conflicting. We studied the HRQOL of radioiodine-naive DTC patients in comparison with the general population (GP), investigated the course of HRQOL up to 30 months after radioiodine remnant ablation (RAA) and sought to identify patient characteristics associated with HRQOL. We analysed data from routine HRQOL monitoring at a nuclear medicine department. Between 2005 and 2013, a total of 439 thyroid cancer patients (all histologies) completed the EORTC Quality of Life Questionnaire Core-30 (QLQ-C30) at least once during their treatment at the department. We compared patients' baseline HRQOL scores before RAA with scores from age-matched and sex-matched controls from the Austrian GP. We then determined the course of HRQOL over the 30 months after RAA and assessed the impact of the following clinical variables on HRQOL: method of thyroid-stimulating hormone (TSH) stimulation, histology (papillary vs. follicular) and disease stage. A total of 284 patients (mean age 48.3 years, SD 15.0 years; 71.6 % women; 80.7 % papillary type) with a baseline HRQOL assessment before RAA were available. We found clinically meaningful differences in the detriment in patients on almost all domains. These were largest for fatigue (23 points) and role functioning (25 points). Data from 241 patients (mean age 48.6 years, SD 15.9 years; 68.9 % women; 76.3 % papillary type) were included in the longitudinal analysis. Investigating the course of HRQOL, a significant improvement over time was found for role and emotional functioning, fatigue, pain, and dyspnoea. A range of HRQOL scores were improved in patients with exogenous TSH stimulation, but some scores both in patients with exogenous TSH stimulation and in those followed for 30 months, especially fatigue and role functioning, did not reach levels in the GP sample. Our results show that

  6. Persistent quality of life impairments in differentiated thyroid cancer patients: results from a monitoring programme

    International Nuclear Information System (INIS)

    Gamper, Eva-Maria; Wintner, Lisa M.; Holzner, Bernhard; Rodrigues, Margarida; Buxbaum, Sabine; Nilica, Bernhard; Virgolini, Irene; Singer, Susanne; Giesinger, Johannes M.

    2015-01-01

    Health-related quality of life (HRQOL) in differentiated thyroid cancer (DTC) research has so far received little attention and available results are conflicting. We studied the HRQOL of radioiodine-naive DTC patients in comparison with the general population (GP), investigated the course of HRQOL up to 30 months after radioiodine remnant ablation (RAA) and sought to identify patient characteristics associated with HRQOL. We analysed data from routine HRQOL monitoring at a nuclear medicine department. Between 2005 and 2013, a total of 439 thyroid cancer patients (all histologies) completed the EORTC Quality of Life Questionnaire Core-30 (QLQ-C30) at least once during their treatment at the department. We compared patients' baseline HRQOL scores before RAA with scores from age-matched and sex-matched controls from the Austrian GP. We then determined the course of HRQOL over the 30 months after RAA and assessed the impact of the following clinical variables on HRQOL: method of thyroid-stimulating hormone (TSH) stimulation, histology (papillary vs. follicular) and disease stage. A total of 284 patients (mean age 48.3 years, SD 15.0 years; 71.6 % women; 80.7 % papillary type) with a baseline HRQOL assessment before RAA were available. We found clinically meaningful differences in the detriment in patients on almost all domains. These were largest for fatigue (23 points) and role functioning (25 points). Data from 241 patients (mean age 48.6 years, SD 15.9 years; 68.9 % women; 76.3 % papillary type) were included in the longitudinal analysis. Investigating the course of HRQOL, a significant improvement over time was found for role and emotional functioning, fatigue, pain, and dyspnoea. A range of HRQOL scores were improved in patients with exogenous TSH stimulation, but some scores both in patients with exogenous TSH stimulation and in those followed for 30 months, especially fatigue and role functioning, did not reach levels in the GP sample. Our results show that

  7. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    Science.gov (United States)

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  8. CALiPER Retail Lamps Study RRL3.2 Lumen and Chromaticity Maintenance of LED A lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McCullough, Jeffrey J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Joseph C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The lumen depreciation and color shift of 17 different A lamps (15 LED, 1 CFL, 1 halogen) was monitored in the automated long-term test apparatus (ALTA) for more than 7,500 hours. Ten samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at an ambient temperature of 45°C (-1°C). Importantly, the steady-state test conditions were not optimized for inducing catastrophic failure for any of the lamp technologies—to which thermal cycling is a strong contributor— and are not typical of normal use patterns—which usually include off periods where the lamp cools down. Further, the test conditions differ from those used in standardized long-term test methods (i.e., IES LM-80, IES LM-84), so the results should not be directly compared. On the other hand, the test conditions are similar to those used by ENERGY STAR (when elevated temperature testing is called for). Likewise, the conditions and assumptions used by manufacturers to generated lifetime claims may vary; the CALiPER long-term data is informative, but cannot necessarily be used to discredit manufacturer claims. The test method used for this investigation should be interpreted as one more focused on the long-term effects of elevated temperature operation, at an ambient temperature that is not uncommon in luminaires. On average, the lumen maintenance of the LED lamps monitored in the ALTA was better than benchmark lamps, but there was considerable variation from lamp model to lamp model. While three lamp models had average lumen maintenance above 99% at the end of the study period, two products had average lumen maintenance below 65%, constituting a parametric failure. These two products, along with a third, also exhibited substantial color shift, another form of parametric failure. While none of the LED lamps exhibited catastrophic failure—and all of the benchmarks did—the early degradation of performance is concerning, especially with a

  9. Radioactivity in the environment. Report for 1999. A summary and radiological assessment of the Environment Ageny's monitoring programmes

    International Nuclear Information System (INIS)

    1999-01-01

    The Environment Agency has wide-ranging responsibilities and powers to protect and, where necessary, improve the environment in England and Wales. The Agency also has a duty to protect the environment in a way that works towards sustainable development. In 1998, the Oslo and Paris Commission (OSPAR) strategy for radioactive substances was agreed by Ministers at Sintra, Portugal, to prevent pollution of the North East Atlantic maritime area through progressive and substantial reductions in discharges, emissions and losses of radioactive substances. In June 2000, the UK Government published for consultation the draft UK Strategy for Radioactive Discharges 2001-2020 which sets out the UK's plans to implement the OSPAR strategy. The Government will be issuing statutory guidance to the Environment Agency which will provide the vehicle through which the UK Strategy will be implemented. Radiological monitoring programmes are carried out in support of the Agency's regulatory functions under RSA 93 and as part of the UK Government's obligations under the Euratom Treaty. This report presents the results of the Agency's regular monitoring of radioactivity in the environment during 1999 and an assessment of the radiological impact. The main findings of the regular monitoring programme during 1999 were as follows: (i) The majority of operator declarations of the radioactive content of wastes discharges and disposals had been assessed accurately or were over estimated. (ii) Radiation dose-rates above sediments and concentrations of radionuclides in water, sediment, soil and grass were generally consistent with those reported in previous years, with no clear trend over the last 10 years. Enhanced levels of artificial radionuclides continue to be found in coastal sediments in the vicinity of Sellafield, which decline with increasing distance from the site. Radioactivity levels around other major sites were mostly low or not detectable. (iii) As in previous years, concentrations of

  10. Collisional and radiative processes in fluorescent lamps

    International Nuclear Information System (INIS)

    Lister, Graeme G.

    2003-01-01

    Since electrode life is the major limiting factor in operating fluorescent lamps, many lighting companies have introduced 'electrodeless' fluorescent lamps, using inductively coupled discharges. These lamps often operate at much higher power loadings than standard lamps and numerical models have not been successful in reproducing experimental measurements in the parameter ranges of interest. A comprehensive research program was undertaken to study the fundamental physical processes of these discharges, co-funded by the Electric Power Research Institute (EPRI) and OSRAM SYLVANIA under the name of ALITE. The program included experiments and modeling of radiation transport, computations of electron-atom and atom-atom cross sections and the first comprehensive power balance studies of a highly loaded fluorescent lamp. Results from the program and their importance to the understanding of the physics of fluorescent lamps are discussed, with particular emphasis on the important collisional and radiative processes. Comparisons between results of experimental measurements and numerical models are presented

  11. Lamp with a truncated reflector cup

    Science.gov (United States)

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  12. Reduction of operative mortality after implementation of Surgical Outcomes Monitoring and Improvement Programme by Hong Kong Hospital Authority.

    Science.gov (United States)

    Yuen, W C; Wong, K; Cheung, Y S; Lai, P Bs

    2018-04-01

    Since 2008, the Hong Kong Hospital Authority has implemented a Surgical Outcomes Monitoring and Improvement Programme (SOMIP) at 17 public hospitals with surgical departments. This study aimed to assess the change in operative mortality rate after implementation of SOMIP. The SOMIP included all Hospital Authority patients undergoing major/ultra-major procedures in general surgery, urology, plastic surgery, and paediatric surgery. Patients undergoing liver or renal transplantation or who had multiple trauma or massive bowel ischaemia were excluded. In SOMIP, data retrieval from the Hospital Authority patient database was performed by six full-time nurse reviewers following a set of precise data definitions. A total of 230 variables were collected for each patient, on demographics, preoperative and operative variables, laboratory test results, and postoperative complications up to 30 days after surgery. In this study, we used SOMIP cumulative 5-year data to generate risk-adjusted 30-day mortality models by hierarchical logistic regression for both emergency and elective operations. The models expressed overall performance as an annual observed-to-expected mortality ratio. From 2009/2010 to 2015/2016, the overall crude mortality rate decreased from 10.8% to 5.6% for emergency procedures and from 0.9% to 0.4% for elective procedures. From 2011/2012 to 2015/2016, the risk-adjusted observed-to-expected mortality ratios showed a significant downward trend for both emergency and elective operations: from 1.126 to 0.796 and from 1.150 to 0.859, respectively (Mann- Kendall statistic = -0.8; PAuthority's overall crude mortality rates and risk-adjusted observed-to-expected mortality ratios for emergency and elective operations significantly declined after SOMIP was implemented.

  13. Lamp-Ballast Compatibility Index for Efficient Ceramic Metal Halide Lamp Operation

    OpenAIRE

    Sourish Chatterjee

    2013-01-01

    Development of energy efficient products and exploration of energy saving potential are major challenges for present day’s technology. Ceramic Metal Halide lamp is the latest improved version of metal halide lamp that finds its wide applications in indoor commercial lighting especially in retail shop lighting. This lamp shows better performance in terms of higher lumen per watt and colour constancy in comparison to conventional metal halide lamp. The inherent negative incremental impedance of...

  14. VIRTIS-M flight lamps

    International Nuclear Information System (INIS)

    Melchiorri, R.; Piccioni, G.; Mazzoni, A.

    2003-01-01

    VIRTIS-M is a visible-infrared (VIS-IR) image spectrometer designed for the Rosetta mission; it intends to provide detailed informations on the physical, chemical, and mineralogical nature of comets and asteroids. The in-flight performances of VIRTIS-M are expected to be influenced by various disturbances, like the initial strong vibrations of the rocket, the long duration of the experiment (from 2003 to 2010), as well as other possible environmental changes; therefore, an in-flight recalibration procedure is mandatory. Quite often in such kinds of missions, a light emission diode (LED) is employed to calibrate the on-board spectrometers by taking advantage of the relative small dimensions, stability, and hardness of these sources. VIRTIS-M is the first image spectrometer that will use a new generation of lamps for internal calibrations. These new lamps are characterized by a wide spectral range with a blackbody-like emission with an effective temperature of about (2400-2600 K), thereby covering the whole VIRTIS-M's spectral range (0.2-5 μm); i.e., they offer the possibility of a wider spectral calibration in comparison with the quasimonochromatic LED emission. A precise spectral calibration is achieved by adding special filters for visible and infrared ranges in front of the window source, containing many narrow absorption lines. In the present article, we describe the calibration and tests of some flight prototypes of these lamps (VIS and IR), realized by the Officine Galileo and calibrated by the Consiglio Nazionale delle Ricerche-Istituto di Astrofisica Spaziale e Fisica Cosmica

  15. 49 CFR 393.25 - Requirements for lamps other than head lamps.

    Science.gov (United States)

    2010-10-01

    ... listed in paragraph (c) of this section. If motor vehicle equipment (e.g., mirrors, snow plows, wrecker...: J586—Stop Lamps for Use on Motor Vehicles Less Than 2032 mm in Overall Width, March 2000; J2261 Stop Lamps and Front- and Rear-Turn Signal Lamps for Use on Motor Vehicles 2032 mm or More in Overall Width...

  16. Radioactivity in the environment. Report for 2001 : a summary and radiological assessment of the Environment Agency's monitoring programmes

    International Nuclear Information System (INIS)

    2003-01-01

    RSA 93 authorisations. Radiological monitoring programmes are carried out in support of the Agency's regulatory functions under RSA 93 and as part of the UK Government's obligations under the Euratom Treaty. This report presents the results of the Agency's regular monitoring of radioactivity in the environment during 2001 and an assessment of the radiological impact. The main findings of the regular monitoring programme during 2001 were as follows: The majority of operator declarations of the radioactive content of waste discharges and disposals had been assessed accurately or were over-estimate; Radiation dose rates above sediments and concentrations of radionuclides in water, sediment, soil and grass were generally consistent with those reported in previous years. Enhanced levels of artificial radionuclides continue to be found in coastal sediments in the vicinity of Sellafield, which decline with increasing distance from the site. Radioactivity levels around other major sites were mostly low or not detectable; As in previous years, concentrations of radionuclides in samples of airborne dust and rainwater from seven locations in the UK were very low or undetectable; Water from all 31 monitored sources of drinking water in England and Wales, except one in Derbyshire, were consistently below the World Health Organisation (WHO) drinking water screening levels. The enhanced level of uranium in the Derbyshire water is due to the natural levels of uranium in the local geology, and is insignificant from a radiological point of view. Assessments of doses that might be received by members of the public from drinking water and occupation of beaches, inter-tidal areas and river banks around nuclear and major non-nuclear sites were made. In all cases, doses were less than the annual dose limit for members of the public of 1000 microsieverts (1000 μSv). Houseboat dwellers on the Ribble Estuary in Lancashire received the highest total annual dose of 142 μSv. This is due to

  17. Discharge lamp with reflective jacket

    Science.gov (United States)

    MacLennan, Donald A.; Turner, Brian P.; Kipling, Kent

    2001-01-01

    A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

  18. Introduction to the European Monitoring and Evaluation Programme (EMEP and observed atmospheric composition change during 1972–2009

    Directory of Open Access Journals (Sweden)

    K. E. Yttri

    2012-06-01

    Full Text Available European scale harmonized monitoring of atmospheric composition was initiated in the early 1970s, and the activity has generated a comprehensive dataset (available at http://www.emep.int which allows the evaluation of regional and spatial trends of air pollution during a period of nearly 40 yr. Results from the monitoring made within EMEP, the European Monitoring and Evaluation Programme, show large reductions in ambient concentrations and deposition of sulphur species during the last decades. Reductions are in the order of 70–90% since the year 1980, and correspond well with reported emission changes. Also reduction in emissions of nitrogen oxides (NOx are reflected in the measurements, with an average decrease of nitrogen dioxide and nitrate in precipitation by about 23% and 25% respectively since 1990. Only minor reductions are however seen since the late 1990s. The concentrations of total nitrate in air have decreased on average only by 8% since 1990, and fewer sites show a significant trend. A majority of the EMEP sites show a decreasing trend in reduced nitrogen both in air and precipitation on the order of 25% since 1990. Deposition of base cations has decreased during the past 30 yr, and the pH in precipitation has increased across Europe. Large inter annual variations in the particulate matter mass concentrations reflect meteorological variability, but still there is a relatively clear overall decrease at several sites during the last decade. With few observations going back to the 1990s, the observed chemical composition is applied to document a change in particulate matter (PM mass even since 1980. These data indicate an overall reduction of about 5 μg m−3 from sulphate alone. Despite the significant reductions in sulphur emissions, sulphate still remains one of the single most important compounds contributing to regional scale aerosol mass concentration. Long-term ozone trends at EMEP sites show a mixed pattern. The year

  19. Application of mobile-technology for disease and treatment monitoring of malaria in the "Better Border Healthcare Programme"

    Directory of Open Access Journals (Sweden)

    Meankaew Pongthep

    2010-08-01

    Full Text Available Abstract Background The main objective of this study was to assess the effectiveness of integrating the use of cell-phones into a routine malaria prevention and control programme, to improve the management of malaria cases among an under-served population in a border area. The module for disease and treatment monitoring of malaria (DTMM consisted of case investigation and case follow-up for treatment compliance and patients' symptoms. Methods The module combining web-based and mobile technologies was developed as a proof of concept, in an attempt to replace the existing manual, paper-based activities that malaria staff used in treating and caring for malaria patients in the villages for which they were responsible. After a patient was detected and registered onto the system, case-investigation and treatment details were recorded into the malaria database. A follow-up schedule was generated, and the patient's status was updated when the malaria staff conducted their routine home visits, using mobile phones loaded with the follow-up application module. The module also generated text and graph messages for a summary of malaria cases and basic statistics, and automatically fed to predetermined malaria personnel for situation analysis. Following standard public-health practices, access to the patient database was strictly limited to authorized personnel in charge of patient case management. Results The DTMM module was developed and implemented at the trial site in late November 2008, and was fully functioning in 2009. The system captured 534 malaria patients in 2009. Compared to paper-based data in 2004-2008, the mobile-phone-based case follow-up rates by malaria staff improved significantly. The follow-up rates for both Thai and migrant patients were about 94-99% on Day 7 (Plasmodium falciparum and Day 14 (Plasmodium vivax and maintained at 84-93% on Day 90. Adherence to anti-malarial drug therapy, based on self-reporting, showed high completion

  20. Irradiation temperature measurement of the reactor pressure vessel surveillance specimen in the programmes of radiation degradation monitoring

    International Nuclear Information System (INIS)

    Kupca, L.; Stanc, S.; Simor, S.

    2001-01-01

    The information's about the special system of irradiation temperature measurement, used for reactor pressure vessel surveillance specimen, which are placed in reactor thermal shielding canals are presented in the paper. The system was designed and realized in the frame of Extended Surveillance Specimen Programme for NPP V-2 Jaslovske Bohunice and Modern Surveillance Specimen Programme for NPP Mochovce. Base design aspects, technical parameters of realization and results of measurement on the two units in Bohunice and Mochovce NPPs are presented too. (Authors)

  1. Diode-laser-illuminated automotive lamp systems

    Science.gov (United States)

    Marinelli, Michael A.; Remillard, Jeffrey T.

    1998-05-01

    We have utilized the high brightness of state-of-the-art diode laser sources, and a variety of emerging optical technologies to develop a new class of thin, uniquely styled automotive brake and signal lamps. Using optics based on thin (5 mm) plastic sheets, these lamps provide appearance and functional advantages not attainable with traditional automotive lighting systems. The light is coupled into the sheets using a 1 mm diameter glass fiber, and manipulated using refraction and reflection from edges, surfaces, and shaped cut-outs. Light can be extracted with an efficiency of approximately 50% and formed into a luminance distribution that meets the Society of Automotive Engineers (SAE) photometric requirements. Prototype lamps using these optics have been constructed and are less than one inch in thickness. Thin lamps reduce sheet metal costs, complexity, material usage, weight, and allow for increased trunk volume. In addition, these optics enhance lamp design flexibility. When the lamps are not energized, they can appear body colored, and when lighted, the brightness distribution across the lamp can be uniform or structured. A diode laser based brake lamp consumes seven times less electrical power than one using an incandescent source and has instant on capability. Also, diode lasers have the potential to be 10-year/150,000 mile light sources.

  2. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  3. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  4. 20th annual report 2011. Convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. (eds.)

    2011-07-01

    The Integrated Monitoring Programme (ICP IM) is part of the effect-oriented activities under the 1979 Convention on Long-range Transboundary Air Pollution, which covers the region of the United Nations Economic Commission for Europe (UNECE). The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in natural/semi natural ecosystems. This report summarizes the work carried out by the ICP IM Programme Centre and several collaborating institutes. The emphasis of the report is in the work done during the programme year 2010/2011 including: A short summary of previous data assessments, a status report of the ICP IM activities, content of the IM database, and geographical coverage of the monitoring network, a review of published vegetation results from ICP IM and preliminary analyses of collected vegetation data, a report on updated heavy metal budgets and critical loads at ICP IM sites, report on benefits of LTER collaboration (Long Term Ecological Research network, www.lter-europe.net), National Reports on ICP IM activities are presented as annexes. (orig.)

  5. 22nd annual report 2013. Convention on long-range transboundary air pollution. International cooperative programme on integrated monitoring of air pollution effects on ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Kleemola, S.; Forsius, M. (eds.)

    2013-09-01

    The Integrated Monitoring Programme (ICP IM) is part of the effect-oriented activities under the 1979 Convention on Long-range Transboundary Air Pollution, which covers the region of the United Nations Economic Commission for Europe (UNECE). The main aim of ICP IM is to provide a framework to observe and understand the complex changes occurring in natural/semi natural ecosystems. This report summarizes the work carried out by the ICP IM Programme Centre and several collaborating institutes. The emphasis of the report is in the work done during the programme year 2012/2013 including: A short summary of previous data assessments; A status report of the ICP IM activities, content of the IM database, and geographical coverage of the monitoring network; A final report on relations between vegetation changes and nitrogen Critical Load exceedance; A progress report on base line heavy metal approach, estimation of the extent of metal turnover in European forest catchments over the last decades; A final report on sulphur and nitrogen input-output budgets at ICP IM sites in Europe; National Reports on ICP IM activities are presented as annexes.

  6. A study on monitoring methodology for trace elements in the environment through chemical analysis of hair. Part of a coordinated programme on nuclear methods in health-related monitoring of trace element pollutants

    International Nuclear Information System (INIS)

    Fukushima, I.

    1981-06-01

    An attempt was made to monitor community exposure to environmental As, Cd, Cr, Hg, Mn, Pb and Se using hair analysis by instrumental neutron activation analysis and atomic absorption spectroscopy. Hair samples were collected from male and female subjects from six Japanese localities. Samples from each locality were respectively mixed and analysed for elements of interest. The results indicated that this approach was effective in revealing geographical differences of hair elemental levels. The method is suitable for a routine monitoring programme of community exposure to environmental metal pollutants

  7. Desktop mapping using GPS. SAHTI - a software package for environmental monitoring. Report on task JNTB898 on the Finnish support programme to IAEA safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Ilander, T; Kansanaho, A; Toivonen, H

    1996-02-01

    Environmental sampling is the key method of the IAEA in searching signatures of a covert nuclear programme. However, it is not always easy to know the exact location of the sampling site. The satellite navigation system, utilizing a small receiver (GPS) and a PC, allows to have independent positioning data easily. The present task on the Finnish Support Programme was launched to create software to merge information about sampling and positioning. The system is build above a desktop mapping software package. However, the result of the development goes beyond the initial goal: the software can be used to real- time positioning in a mobile unit utilizing maps that can be purchased or produced by the user. In addition, the system can be easily enlarged to visualize data in real time from mobile environmental monitors, such as a Geiger counter, a pressurized ionisation chamber of a gamma-ray spectrometer. (orig.) (7 figs.).

  8. Desktop mapping using GPS. SAHTI - a software package for environmental monitoring. Report on task JNTB898 on the Finnish support programme to IAEA safeguards

    International Nuclear Information System (INIS)

    Ilander, T.; Kansanaho, A.; Toivonen, H.

    1996-02-01

    Environmental sampling is the key method of the IAEA in searching signatures of a covert nuclear programme. However, it is not always easy to know the exact location of the sampling site. The satellite navigation system, utilizing a small receiver (GPS) and a PC, allows to have independent positioning data easily. The present task on the Finnish Support Programme was launched to create software to merge information about sampling and positioning. The system is build above a desktop mapping software package. However, the result of the development goes beyond the initial goal: the software can be used to real- time positioning in a mobile unit utilizing maps that can be purchased or produced by the user. In addition, the system can be easily enlarged to visualize data in real time from mobile environmental monitors, such as a Geiger counter, a pressurized ionisation chamber of a gamma-ray spectrometer. (orig.) (7 figs.)

  9. Results of a monitoring programme in the environs of Berkeley aimed at collecting Chernobyl data for foodchain model validation

    International Nuclear Information System (INIS)

    Nair, S.; Darley, P.J.; Shaer, J.

    1989-03-01

    The results of a fallout measurement programme which was carried out in the environs of Berkeley Nuclear Laboratory in the United Kingdom following the Chernobyl reactor accident in April 1986 are presented in this report. The programme was aimed at establishing a time-dependent data base of concentrations of Chernobyl fallout radionuclides in selected agricultural products. Results were obtained for milk, grass, silage, soil and wheat over an eighteen month period from May 1986. It is intended to use the data to validate the CEGB's dynamic foodchain model, which is incorporated in the FOODWEB module of the NECTAR environmental code. (author)

  10. Development of Web based system for individual internal monitoring programme; Desenvolvimento de um sistema baseado na Web para suporte ao programa de monitoracao individual interna do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Vanessa Rogeria de

    2007-07-01

    The purposes of the internal monitoring, in general, are to verify and document that each worker is protected adequately against risks from radionuclide intakes and the protection complies with legal requirements. Therefore, an overall radiation protection programme, starts with an assessment to identify work situations in which there is a risk of internal contamination of workers and to quantify the likely intake of radioactive material and the resulting committed effective dose. As a part of a continuous improvement of the monitoring programme for occupationally exposed workers at IPEN, it is being developed a Web based system to access the internal dosimetry database. The system was implemented using Hypertext Preprocessor, PHP, and a PostgreSQL database. This system will introduce a new paradigm in the routine of the internal dosimetry service, providing a fast access to the information among the measurement laboratories staff, dose evaluation group and the radiation protection supervisor. The database maintains information about worker identification, physical and chemical characteristics of the radionuclide, type of monitoring, measurement data and the dose. Moreover, this information will be readily available to provide support for regulatory compliance and quality control requirements. (author)

  11. UHP lamp systems for projection applications

    International Nuclear Information System (INIS)

    Derra, Guenther; Moench, Holger; Fischer, Ernst; Giese, Hermann; Hechtfischer, Ulrich; Heusler, Gero; Koerber, Achim; Niemann, Ulrich; Noertemann, Folke-Charlotte; Pekarski, Pavel; Pollmann-Retsch, Jens; Ritz, Arnd; Weichmann, Ulrich

    2005-01-01

    Projection systems have found widespread use in conference rooms and other professional applications during the last decade and are now entering the home TV market at a considerable pace. Projectors as small as about one litre are able to deliver several thousand screen lumens and are, with a system efficacy of over 10 lm W -1 , the most efficient display systems realized today. Short arc lamps are a key component for projection systems of the highest efficiency for small-size projection displays. The introduction of the ultra high performance (UHP) lamp system by Philips in 1995 can be identified as one of the key enablers of the commercial success of projection systems. The UHP lamp concept features outstanding arc luminance, a well suited spectrum, long life and excellent lumen maintenance. For the first time it combines a very high pressure mercury discharge lamp with extremely short and stable arc gap with a regenerative chemical cycle keeping the discharge walls free from blackening, leading to lifetimes of over 10 000 h. Since the introduction of the UHP lamp system, many important new technology improvements have been realized: burner designs for higher lamp power, advanced ignition systems, miniaturized electronic drivers and innovative reflector concepts. These achievements enabled the impressive increase of projector light output, a remarkable reduction in projector size and even higher optical efficiency in projection systems during the last years. In this paper the concept of the UHP lamp system is described, followed by a discussion of the technological evolution the UHP lamp has undergone so far. Last, but not least, the important improvements of the UHP lamp system including the electronic driver and the reflector are discussed. (review article)

  12. Application of Wireless Intelligent Control System for HPS Lamps and LEDs Combined Illumination in Road Tunnel

    Science.gov (United States)

    Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo

    2014-01-01

    Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266

  13. Optimization of loop-mediated isothermal amplification (LAMP) assays for the detection of Leishmania DNA in human blood samples.

    Science.gov (United States)

    Abbasi, Ibrahim; Kirstein, Oscar D; Hailu, Asrat; Warburg, Alon

    2016-10-01

    Visceral leishmaniasis (VL), one of the most important neglected tropical diseases, is caused by Leishmania donovani eukaryotic protozoan parasite of the genus Leishmania, the disease is prevalent mainly in the Indian sub-continent, East Africa and Brazil. VL can be diagnosed by PCR amplifying ITS1 and/or kDNA genes. The current study involved the optimization of Loop-mediated isothermal amplification (LAMP) for the detection of Leishmania DNA in human blood or tissue samples. Three LAMP systems were developed; in two of those the primers were designed based on shared regions of the ITS1 gene among different Leishmania species, while the primers for the third LAMP system were derived from a newly identified repeated region in the Leishmania genome. The LAMP tests were shown to be sufficiently sensitive to detect 0.1pg of DNA from most Leishmania species. The green nucleic acid stain SYTO16, was used here for the first time to allow real-time monitoring of LAMP amplification. The advantage of real time-LAMP using SYTO 16 over end-point LAMP product detection is discussed. The efficacy of the real time-LAMP tests for detecting Leishmania DNA in dried blood samples from volunteers living in endemic areas, was compared with that of qRT-kDNA PCR. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. A pulse generator for xenon lamps

    CERN Document Server

    Janata, E

    2002-01-01

    A pulse generator is described, which enhances the analyzing light emitted from a xenon lamp as used in kinetic photospectrometry experiments. The lamp current is increased to 600 A for a duration of 3 ms; the current is constant within +-0.2% during a time interval of 2 ms. Because of instabilities of the lamp arc during pulsing, the use of the enhanced light source is limited to measuring times up to 500 mu s. The enhancement in light intensity depends on the wavelength and amounts to more than 400-fold in the UV-region.

  15. GPS positioning and desktop mapping. Applications to environmental monitoring. Report on task JNT B898 on the Finnish support programme to IAEA safeguards

    International Nuclear Information System (INIS)

    Kansanaho, A.; Ilander, T.; Toivonen, H.

    1995-10-01

    Satellite navigation has been used for in-field applications by the Finnish Centre for Radiation and Nuclear Safety since 1993. Because of this experience, training in the use of GPS positioning and desktop mapping was chosen as a task under the Finnish Support programme to IAEA safeguards. A lecture and a field experiment was held in the training course on environmental monitoring at the IAEA headquarters in June 1995. Real-time mapping of the co-ordinates and storing information on sampling sites and procedures can make safeguards implementation more efficient and effective. Further software development are needed for these purposes. (author) (6 figs.)

  16. CALiPER Retail Lamps Study 3

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Beeson, Tracy A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-02-01

    The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other

  17. LED lamp power management system and method

    Science.gov (United States)

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

    2013-03-19

    An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

  18. CALiPER Report 20.4: Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-30

    This CALiPER report focuses on lumen maintenance, chromaticity maintenance, and catastrophic failure in 32 of the Series 20 LED PAR38 lamps and 8 benchmark lamps, which were monitored for nearly 14,000 hours at ambient temperatures between 44°C and 45°C.

  19. National Environmental Radiation Warning And Monitoring Network And Proposed Radiation Monitoring Programme For The 1st Nuclear Power Plant Ninth Thuan

    International Nuclear Information System (INIS)

    Vuong Thu Bac

    2011-01-01

    National Environmental Radiation Warning and Monitoring Network has been gradually setting up based on some of legislative documents which have been issued in recent years. Studies and surveys to build an environmental radiation monitoring program for nuclear power plant (NPP) have also been implemented. This paper aims to introduce National Environmental Radiation Warning and Monitoring Network in Vietnam which has been approved by the government, the draft program for environmental radiation monitoring Ninh Thuan NPP and some initial results of research about environmental radiation in the planning area for building first NPP in Vietnam. (author)

  20. Luminescence Studies on Lamp Phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Godbole, S.V.; Varadharajan, G.; Page, A.G

    1998-07-01

    Photoluminescence and thermoluminescence of cerium magnesium aluminate CeMgAl{sub 11}O{sub 17}(Eu,Tb) and calcium halophosphate Ca{sub 5}(PO{sub 4}){sub 3}(F,Cl):Mn,Sb, two fluorescent materials currently in use for the commercial production of lamps in India, have been studied for possible applications in radiation and ultraviolet dosimetry. Cerium magnesium aluminate is highly sensitive to the visible spectral region. It has a linear response to 254 nm UV radiation over a wide range. Its UV sensitivity is significantly higher as compared to that of other known phosphors; however, its UV response is rate-dependent and may not play a significant role in UV dosimetry. Photoluminescence of CeMg aluminate is characteristic of Eu{sup 2+} and Tb{sup 3+} dopants, whereas the thermoluminescence emission of the UV irradiated powder at room temperature is dominated by Eu{sup 2+} dopant. Calcium halophosphate is insensitive to room lights, has a linear gamma response over 0.2-10{sup 2} Gy and may be useful in the case of radiation accidents. (author)

  1. Luminescence Studies on Lamp Phosphors

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Godbole, S.V.; Varadharajan, G.; Page, A.G.

    1998-01-01

    Photoluminescence and thermoluminescence of cerium magnesium aluminate CeMgAl 11 O 17 (Eu,Tb) and calcium halophosphate Ca 5 (PO 4 ) 3 (F,Cl):Mn,Sb, two fluorescent materials currently in use for the commercial production of lamps in India, have been studied for possible applications in radiation and ultraviolet dosimetry. Cerium magnesium aluminate is highly sensitive to the visible spectral region. It has a linear response to 254 nm UV radiation over a wide range. Its UV sensitivity is significantly higher as compared to that of other known phosphors; however, its UV response is rate-dependent and may not play a significant role in UV dosimetry. Photoluminescence of CeMg aluminate is characteristic of Eu 2+ and Tb 3+ dopants, whereas the thermoluminescence emission of the UV irradiated powder at room temperature is dominated by Eu 2+ dopant. Calcium halophosphate is insensitive to room lights, has a linear gamma response over 0.2-10 2 Gy and may be useful in the case of radiation accidents. (author)

  2. Optimized positioning of autonomous surgical lamps

    Science.gov (United States)

    Teuber, Jörn; Weller, Rene; Kikinis, Ron; Oldhafer, Karl-Jürgen; Lipp, Michael J.; Zachmann, Gabriel

    2017-03-01

    We consider the problem of finding automatically optimal positions of surgical lamps throughout the whole surgical procedure, where we assume that future lamps could be robotized. We propose a two-tiered optimization technique for the real-time autonomous positioning of those robotized surgical lamps. Typically, finding optimal positions for surgical lamps is a multi-dimensional problem with several, in part conflicting, objectives, such as optimal lighting conditions at every point in time while minimizing the movement of the lamps in order to avoid distractions of the surgeon. Consequently, we use multi-objective optimization (MOO) to find optimal positions in real-time during the entire surgery. Due to the conflicting objectives, there is usually not a single optimal solution for such kinds of problems, but a set of solutions that realizes a Pareto-front. When our algorithm selects a solution from this set it additionally has to consider the individual preferences of the surgeon. This is a highly non-trivial task because the relationship between the solution and the parameters is not obvious. We have developed a novel meta-optimization that considers exactly this challenge. It delivers an easy to understand set of presets for the parameters and allows a balance between the lamp movement and lamp obstruction. This metaoptimization can be pre-computed for different kinds of operations and it then used by our online optimization for the selection of the appropriate Pareto solution. Both optimization approaches use data obtained by a depth camera that captures the surgical site but also the environment around the operating table. We have evaluated our algorithms with data recorded during a real open abdominal surgery. It is available for use for scientific purposes. The results show that our meta-optimization produces viable parameter sets for different parts of an intervention even when trained on a small portion of it.

  3. Public social monitoring reports and their effect on a policy programme aimed at addressing the social determinants of health to improve health equity in New Zealand.

    Science.gov (United States)

    Pega, Frank; Valentine, Nicole B; Matheson, Don; Rasanathan, Kumanan

    2014-01-01

    The important role that monitoring plays in advancing global health is well established. However, the role of social monitoring as a tool for addressing social determinants of health (SDH) and health equity-focused policies remains under-researched. This paper assesses the extent and ways in which New Zealand's (NZ) Social Reports (SRs) supported a SDH- and health equity-oriented policy programme nationally over the 2000-2008 period by documenting the SRs' history and assessing its impact on policies across sectors in government and civil society. We conducted key-informant interviews with five senior policy-makers and an e-mail survey with 24 government and civil society representatives on SRs' history and policy impact. We identified common themes across these data and classified them accordingly to assess the intensity of the reports' use and their impact on SDH- and health equity-focused policies. Bibliometric analyses of government publications and media items were undertaken to empirically assess SRs' impact on government and civil society. SRs in NZ arose out of the role played by government as the "benevolent social welfare planner" and an understanding of the necessity of economic and social security for "progress". The SRs were linked to establishing a government-wide programme aimed at reducing inequalities. They have been used moderately to highly in central and local government and in civil society, both within and outside the health sector, but have neither entered public treasury and economic development departments nor the commercial sector. The SRs have not reached the more universal status of economic indicators. However, they have had some success at raising awareness of, and have stimulated isolated action on, SDH. The NZ case suggests that national-level social monitoring provides a valuable tool for raising awareness of SDH across government and civil society. A number of strategies could improve social reports' effectiveness in stimulating

  4. Max Tech and Beyond: Fluorescent Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp

  5. Oskarshamn site investigation. Hydrogeochemical monitoring programme for core and percussion drilled boreholes 2009. Summary of ground water chemistry results from spring and autumn sampling

    Energy Technology Data Exchange (ETDEWEB)

    Regander, Claes; Bergman, Bo (Sweco Environment AB (Sweden))

    2010-09-15

    This report summarises the results obtained in 2009 from the hydrogeochemical monitoring programme for core and percussion drilled boreholes. During 2009 groundwater sampling has been performed in monitored (permanently installed) boreholes in two sampling periods, spring (May-June), and autumn (October-November). Both in spring and autumn groundwater sampling was carried out in the following 12 sections; HLX28:2, HLX35:2, HLX37:1, HLX39:1, KLX08:4, KLX10:2, KLX10:5, KLX12A:2, KLX15A:3, KLX15A:6, KLX18A:3, KLX19A:3. The programme started in 2005 and since then water sampling has been performed twice every year. The objective of the hydrogeochemical monitoring programme is to determine the groundwater composition in selected sections chosen for this purpose. In 2009 the sampling of core drilled borehole sections has been conducted in time series, where each borehole section has been sampled at seven occasions. Percussion drilled borehole sections has been sampled at three occasions. The final sample in each section was taken when the electric conductivity had reached a stable level. Obtained results from the activities presented here include groundwater chemistry data in accordance with SKB chemistry class 5 including options and SKB chemistry reduced class 5. SKB chemistry reduced class 5 includes analysis of pH, electric conductivity, alkalinity, density, drill water (uranine), major cations (Chapter 5.4), F-, Br-, Cl-, SO{sub 4}2-, Fe(II)/Fe(tot), HS-, DOC, TOC and the isotopes delta2H, delta18O and 3H. Options for SKB chemistry class 5 include even lanthanoids and other trace elements, As, In, I, environmental metals, NH{sub 4}+, nutrient salts and the isotopes delta34S, delta37Cl, 87Sr/86Sr, 10B/11B, delta13C, 226Ra, 222Rn, 238U, 234U, 230Th and 232Th. All data from the activity are stored in the SICADA database

  6. Elsam. Offshore Wind Farm. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2002 - 31. December 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-04-15

    This annual report, which is a baseline and/or an evaluation of the effects of construction phase, is based on extracts from our consultants' annual reports. These annual reports are individual reports, in which surveys have been made during the year 2002 and reported in the beginning of 2003. Detailed information on methods, programmes and conclusions can be found in these reports. In general it should be noted that apparently the construction phase has not had any unintended effects on the parameters surveyed. Therefore we can also conclude that the protective measures established by Elsam, especially scaring devices/ramp-ups for marine mammals, have had the intended effect. Especially interesting parameters that should be mentioned are: Birds: The seagull species 'Herring Gulls' was found to be attracted by the wind farm during the construction period. The number of Divers has decreased, however statistically this decrease is very small as very few Divers have been observed under the baseline. Porpoises: Porpoises generally stayed away from the construction area during pile driving. This effect was intended and scaring devices were deployed in order to ensure that the animals' hearing was not permanently damaged. Seals: The purpose of the programme has not been to show statistically significant effects during the construction phase. The purpose was to get an idea of their behaviour during the construction phase within the wind farm as well as on the reef. It has been concluded that Horns Rev is not used as a foraging area as much as expected. It is used as transit area for bigger foraging sites in the North Sea. Sand eels and Spisula: A baseline survey of sand eels within the wind farm area has been made. It is shown that sand eels are found in the wind farm area. Spisula have been found in the wind farm area but not in the amount expected. Hard substrate habitat: Baseline surveys on fish have been made during the spring of 2002. The

  7. Elsam. Offshore Wind Farm. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2002 - 31. December 2002

    International Nuclear Information System (INIS)

    2003-04-01

    This annual report, which is a baseline and/or an evaluation of the effects of construction phase, is based on extracts from our consultants' annual reports. These annual reports are individual reports, in which surveys have been made during the year 2002 and reported in the beginning of 2003. Detailed information on methods, programmes and conclusions can be found in these reports. In general it should be noted that apparently the construction phase has not had any unintended effects on the parameters surveyed. Therefore we can also conclude that the protective measures established by Elsam, especially scaring devices/ramp-ups for marine mammals, have had the intended effect. Especially interesting parameters that should be mentioned are: Birds: The seagull species 'Herring Gulls' was found to be attracted by the wind farm during the construction period. The number of Divers has decreased, however statistically this decrease is very small as very few Divers have been observed under the baseline. Porpoises: Porpoises generally stayed away from the construction area during pile driving. This effect was intended and scaring devices were deployed in order to ensure that the animals' hearing was not permanently damaged. Seals: The purpose of the programme has not been to show statistically significant effects during the construction phase. The purpose was to get an idea of their behaviour during the construction phase within the wind farm as well as on the reef. It has been concluded that Horns Rev is not used as a foraging area as much as expected. It is used as transit area for bigger foraging sites in the North Sea. Sand eels and Spisula: A baseline survey of sand eels within the wind farm area has been made. It is shown that sand eels are found in the wind farm area. Spisula have been found in the wind farm area but not in the amount expected. Hard substrate habitat: Baseline surveys on fish have been made during the spring of 2002. The programme regarding the

  8. Use of advanced programmable logic controllers to monitor and control the Elmo Bumpy Torus-proof-of-principle device

    International Nuclear Information System (INIS)

    Boyd, B.A.

    1983-01-01

    The Elmo Bumpy Torus - Proof-of-Principle (EBT-P) device is designed with an instrumentation and control system based upon the use of an advanced Programmable Logic Controller (PLC). The modern PLC incorporates many advanced programming features not available in earlier PLC's intended for application to conventional relay logic replacement. The additional power and flexibility of these modern PLC's is especially applicable to an experimental device such as EBT-P which is made up of several complex interrelated subsystems whose operational characteristics will be evolving throughout the lifetime of the device. The rationale for the selection of advanced PLC's for EBT-P and the approach taken to design of the software developed to control EBT-P are the topics addressed in this paper

  9. Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poplawski, Michael E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Charles C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light output compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one

  10. The Authorities' Control and Monitoring Programme for the Fixed Link across Øresund. Benthic Fauna. Common Mussels

    DEFF Research Database (Denmark)

    Petersen, J. K.; Larsen, M. M.; Loo, L.-O.

    Rapporten er udarbejdet af DMU i samarbejde med Tjärnö Marine Biological Laboratory, udgivet af SEMAC JV (Sound Environmental Monitoring and Control Group) for Miljø- og Energiministeriet og Kontroll- och Styrgruppen för Öresundsförbindelsen, Länstyrelsen, Malmø....

  11. A SAR Ice-Motion Processing Chain in Support of PROMICE (Programme for the Monitoring of the Greenland Ice Sheet)

    DEFF Research Database (Denmark)

    Merryman Boncori, John Peter; Dall, Jørgen; Ahlstrøm, A. P.

    2010-01-01

    This paper reports on the development of a SAR icemotion processing chain developed for the PROMICE project – a long-term program funded by the Danish ministry of Climate and Energy to monitor the mass budget of the Greenland ice sheet. The end goal of the SAR data processing is to output map-pro...

  12. Optical radiation emissions from compact fluorescent lamps

    International Nuclear Information System (INIS)

    Khazova, M.; O'Hagan, J.B.

    2008-01-01

    There is a drive to energy efficiency to mitigate climate change. To meet this challenge, the UK Government has proposed phasing out incandescent lamps by the end of 2011 and replacing them with energy efficient fluorescent lighting, including compact fluorescent lamps (CFLs) with integrated ballasts. This paper presents a summary of an assessment conducted by the Health Protection Agency in March 2008 to evaluate the optical radiation emissions of CFLs currently available in the UK consumer market. The study concluded that the UV emissions from a significant percentage of the tested CFLs with single envelopes may result in foreseeable overexposure of the skin when these lamps are used in desk or task lighting applications. The optical output of all tested CFLs, in addition to high-frequency modulation, had a 100-Hz envelope with modulation in excess of 15%. This degree of modulation may be linked to a number of adverse effects. (authors)

  13. Generation of ion-acoustic waves in an inductively coupled, low-pressure discharge lamp

    International Nuclear Information System (INIS)

    Camparo, J. C.; Klimcak, C. M.

    2006-01-01

    For a number of years it has been known that the alkali rf-discharge lamps used in atomic clocks can exhibit large amplitude intensity oscillations. These oscillations arise from ion-acoustic plasma waves and have typically been associated with erratic clock behavior. Though large amplitude ion-acoustic plasma waves are clearly deleterious for atomic clock operation, it does not follow that small amplitude oscillations have no utility. Here, we demonstrate two easily implemented methods for generating small amplitude ion-acoustic plasma waves in alkali rf-discharge lamps. Furthermore, we demonstrate that the frequency of these waves is proportional to the square root of the rf power driving the lamp and therefore that their examination can provide an easily accessible parameter for monitoring and controlling the lamp's plasma conditions. This has important consequences for precise timekeeping, since the atomic ground-state hyperfine transition, which is the heart of the atomic clock signal, can be significantly perturbed by changes in the lamp's output via the ac-Stark shift

  14. A Field Programmable Gate Array-Based Reconfigurable Smart-Sensor Network for Wireless Monitoring of New Generation Computer Numerically Controlled Machines

    Directory of Open Access Journals (Sweden)

    Ion Stiharu

    2010-08-01

    Full Text Available Computer numerically controlled (CNC machines have evolved to adapt to increasing technological and industrial requirements. To cover these needs, new generation machines have to perform monitoring strategies by incorporating multiple sensors. Since in most of applications the online Processing of the variables is essential, the use of smart sensors is necessary. The contribution of this work is the development of a wireless network platform of reconfigurable smart sensors for CNC machine applications complying with the measurement requirements of new generation CNC machines. Four different smart sensors are put under test in the network and their corresponding signal processing techniques are implemented in a Field Programmable Gate Array (FPGA-based sensor node.

  15. The OECD/NEA programme on radon and thoron dosimetry and monitoring: its contribution to the assessment of public exposure to natural radiation

    International Nuclear Information System (INIS)

    Ilari, O.; Steinhaeusler, F.

    1984-01-01

    Inhalation of radon, thoron and their daughters is recognised to be the most important pathway to exposure of mankind to natural radiation sources. The progressive understanding of the increasing role of this exposure in the overall radiation detriment to the public and the workers produced an increasing concern in several countries about the problems of dosimetry and measurement of these nuclides. This trend was readily appreciated by NEA, which began an active programme in this field in 1976. The effort of NEA focussed on two main areas, namely (a) development of dosimetric models and study of correlation between exposure and dose (Phase I), and (b) review of principles and techniques of metrology and development of guidance on monitoring (Phase II). (author)

  16. A Field Programmable Gate Array-Based Reconfigurable Smart-Sensor Network for Wireless Monitoring of New Generation Computer Numerically Controlled Machines

    Science.gov (United States)

    Moreno-Tapia, Sandra Veronica; Vera-Salas, Luis Alberto; Osornio-Rios, Roque Alfredo; Dominguez-Gonzalez, Aurelio; Stiharu, Ion; de Jesus Romero-Troncoso, Rene

    2010-01-01

    Computer numerically controlled (CNC) machines have evolved to adapt to increasing technological and industrial requirements. To cover these needs, new generation machines have to perform monitoring strategies by incorporating multiple sensors. Since in most of applications the online Processing of the variables is essential, the use of smart sensors is necessary. The contribution of this work is the development of a wireless network platform of reconfigurable smart sensors for CNC machine applications complying with the measurement requirements of new generation CNC machines. Four different smart sensors are put under test in the network and their corresponding signal processing techniques are implemented in a Field Programmable Gate Array (FPGA)-based sensor node. PMID:22163602

  17. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  18. Excimer lamp pumped by a triggered discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G.; Bollanti, S.; Di Lazzaro, P.; Flora, F.; Giordano, G.; Letardi, T.; Renieri, A.; Schina, G. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Clementi, G.; Muzzi, F.; Zheng, C.E. [EL.EN. (Electronic Engineering), Florence (Italy)

    1996-11-01

    Radiation characteristics and discharge performances of an excimer lamp are described. The discharge of the HCl/Xe gas mixture at an atmospheric pressure, occurring near the quartz tube wall, is initiated by a trigger wire. A maximum total UV energy of about 0.4 J in a (0.8-0.9) {mu}s pulse, radiated from a 10 cm discharge length, is obtained with a total discharge input energy of 8 J. Excimer lamps are the preferred choice for medical and material processing irradiations, when the monochromaticity or coherence of UV light is not required, due to their low cost, reliability and easy maintenance.

  19. Use of germicidal lamps in the disinfection of sanitary wastewater

    Directory of Open Access Journals (Sweden)

    Patrícia Bilotta

    2012-04-01

    Full Text Available The objective of this study was to investigate the efficiency of germicidal lamps in the tertiary treatment of sewage to control pathogens. The performance of the photochemical reactor used in the tests was monitored by microbiological analyses to quantify E. coli (bacteria indicator, C. perfringens (protozoa indicator, coliphages (virus indicator. The experiments were performed with effluent from an UASB reactor installed at the WTP- USP São Carlos campus subjected to an aerated submerged biological filter and a photochemical reactor with radiation UV at 254 nm. The results showed that the indicators coliphages and E. coli showed the least resistance to UV radiation reaching removal from 1.70 to 3.90 log and 1.60 to 5.20 log, respectively. On the other hand, the indicator C. perfringens was more resistant to the effect of germicidal lamps reaching values between 0.0 (no inactivation and 1.30 log. For SST concentrations greater than 100.0 mg.L-1, the effect of the germicidal lamps became less pronounced. However, in practice it was possible to notice significant results in tests with TSS concentrations of 135.0 mg.L-1. The experimental approach proved the usefulness of the combined method for inactivating pathogens commonly found in domestic sewage. Besides meeting the standards established by the Brazilian regulation, the final effluent is in agreement with the guidelines defined by WHO. This allows the reuse of the final effluent for unrestricted irrigation, although complementary examination must be performed.

  20. Market research on the use of energy saving lamps in the domestic sector

    Energy Technology Data Exchange (ETDEWEB)

    Kofod, C.; Naser, L.; Rahbar, A.

    1996-06-01

    During the past few years, many campaigns have been carried out to encourage customers to use compact fluorescent lamps (CFLs) instead of incandescent lamps. Information has been retrieved from 26 different programmes carried out in the period 1988-94, including different combinations of direct installations, rebates, give-away, wholesale discounts, and pay-on-the-bill schemes. A very broad range of promotional strategies have been employed including direct mail, give-aways, articles and/or advertisements in newspapers, brochures, TV and/or radio announcements. The percentage of customers who use CFLs in Denmark, Germany and the Netherlands is close to 50%. The use per residence depends firstly on the type, and secondly on the size of the residence and the number of inhabitants. Use of CFLs instead of incandescent lamps gives a favourable Benefit cost Ratio (BCR) for the customer as well as for the society. The main barrier to the procurement of CFLs in the three countries analyzed is that customers find the price of CFLs too high in comparison with incandescent lamps. (EG) 22 refs.

  1. Guide: Monitoring Programme for unannounced inspections undertaken against the National Standards for the Prevention and Control of Healthcare Associated Infections

    LENUS (Irish Health Repository)

    O'Brien, D

    2009-10-01

    All medical doctors have an important role to play in the diagnosis, management and prevention of healthcare-associated infection (HCAI). Strengthening the contribution of medical doctors and medical students to HCAI prevention programmes should include measures that enhance knowledge, improve practice and develop appropriate attitudes to the safety and quality of patient care. The Hospital Infection Society (HIS) funded a review of medical education on HCAI throughout medical schools in the UK and the Republic of Ireland. A questionnaire was drafted and circulated to all medical schools and 31 of 38 (82%) responded. The prevalence and transmission of HCAI were taught by 97% and 100% of medical schools, respectively, but the importance of HCAI as a quality and safety issue was covered in only 60% of medical schools. Multiple choice questions (MCQs) and objective structure clinical examinations (OSCEs) were the most popular methods of assessment. Lectures, discussion of cases and practical demonstrations were considered useful by >90% of respondents and online material and log books by 67% and 60%, respectively. More than 80% were willing to share a common pool of educational resources. An agreed curriculum should be developed for educating medical students in HCAI prevention and control, to outline optimum methods for assessment and develop a shared pool of educational resources.

  2. Laboratory Evaluation of LED T8 Replacement Lamp Products

    Energy Technology Data Exchange (ETDEWEB)

    Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

    2011-05-23

    A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

  3. 21 CFR 866.2600 - Wood's fluorescent lamp.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2600 Wood's fluorescent lamp. (a) Identification. A Wood's fluorescent lamp is a device intended for medical purposes to detect...

  4. Circular, explosion-proof lamp provides uniform illumination

    Science.gov (United States)

    1966-01-01

    Circular explosion-proof fluorescent lamp is fitted around a TV camera lens to provide shadowless illumination with a low radiant heat flux. The lamp is mounted in a transparent acrylic housing sealed with clear silicone rubber.

  5. Measuring hospital-acquired pressure injuries: A surveillance programme for monitoring performance improvement and estimating annual prevalence.

    Science.gov (United States)

    Jull, Andrew; McCall, Elaine; Chappell, Matt; Tobin, Sam

    2016-06-01

    To describe a surveillance approach for monitoring the effect of improvement initiatives on hospital-acquired pressure injuries and findings arising from that surveillance. Random sampling of patients on the same day of each successive month from a campus of child and adult hospitals using a standard audit tool to identify presence of hospital-acquired pressure injury. Where multiple pressure injuries were present, the most severe grade injury contributed to prevalence. Statistical process control charts were used to monitor monthly performance and Maximum Likelihood Estimation to determine timing of step change. 8274 patients were assessed over 3 years from an eligible population of 32,259 hospitalised patients. 517 patients had hospital-acquired pressure injuries giving an overall prevalence of 6.2% (95% CI 5.7-6.8%). Annual prevalence was 8.4% (95% CI 7.4-9.5%) in the first year, falling to 5.6% (95% CI 4.7-6.4%) in the second year and 4.8% (95% CI 4.0-5.6%) in the third year. A step change was signalled with mean prevalence up to July 2013 being 7.9% (95% CI 7.1-8.8%) and mean prevalence thereafter 4.8% (95% CI 4.2-5.4%). Hospital-acquired pressure injuries were found in all age ranges, but were more frequent in children up to 14 years (17.4%) and those aged 75 years or older (38.7%). Monthly random sampling of patients within clinical units can be used to monitor performance improvement. This approach represents a rational alternative to cross-sectional prevalence surveys especially if the focus is on performance improvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. New design for a microwave discharge lamp.

    Science.gov (United States)

    Glangetas, A

    1980-03-01

    A simple discharge lamp with a microwave cavity fitting inside provides an intense source of VUV resonance radiation for photochemical work inside a vacuum chamber. Good coupling and minimum reabsorption result in better efficiency ( greater, similar1%) and more intense output power (up to 2.5x10(16) quanta s(-1)) than have been achieved previously.

  7. Scanning For Hotspots In Lamp Filaments

    Science.gov (United States)

    Powers, Charles E.; Van Sant, Tim; Leidecker, Henning

    1993-01-01

    Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

  8. Breakdown characteristics of xenon HID Lamps

    Science.gov (United States)

    Babaeva, Natalia; Sato, Ayumu; Brates, Nanu; Noro, Koji; Kushner, Mark

    2009-10-01

    The breakdown characteristics of mercury free xenon high intensity discharge (HID) lamps exhibit a large statistical time lag often having a large scatter in breakdown voltages. In this paper, we report on results from a computational investigation of the processes which determine the ignition voltages for positive and negative pulses in commercial HID lamps having fill pressures of up to 20 atm. Steep voltage rise results in higher avalanche electron densities and earlier breakdown times. Circuit characteristics also play a role. Large ballast resistors may limit current to the degree that breakdown is quenched. The breakdown voltage critically depends on cathode charge injection by electric field emission (or other mechanisms) which in large part controls the statistical time lag for breakdown. For symmetric lamps, ionization waves (IWs) simultaneously develop from the bottom and top electrodes. Breakdown typically occurs when the top and bottom IWs converge. Condensed salt layers having small conductivities on the inner walls of HID lamps and on the electrodes can influence the ignition behavior. With these layers, IWs tend to propagate along the inner wall and exhibit a different structure depending on the polarity.

  9. 100 years of Wood's lamp revised

    NARCIS (Netherlands)

    Klatte, J. L.; van der Beek, N.; Kemperman, P. M. J. H.

    2015-01-01

    The Wood's lamp is a diagnostic tool in dermatology. Unfortunately, this useful tool is often overlooked in the busy and hectic outdoor dermatology clinic. To emphasize its value in modern dermatology, we present an updated review of the principles and applications and shed new light on its proper

  10. GeneXpert HIV-1 quant assay, a new tool for scale up of viral load monitoring in the success of ART programme in India.

    Science.gov (United States)

    Kulkarni, Smita; Jadhav, Sushama; Khopkar, Priyanka; Sane, Suvarna; Londhe, Rajkumar; Chimanpure, Vaishali; Dhilpe, Veronica; Ghate, Manisha; Yelagate, Rajendra; Panchal, Narayan; Rahane, Girish; Kadam, Dilip; Gaikwad, Nitin; Rewari, Bharat; Gangakhedkar, Raman

    2017-07-21

    Recent WHO guidelines identify virologic monitoring for diagnosing and confirming ART failure. In view of this, validation and scale up of point of care viral load technologies is essential in resource limited settings. A systematic validation of the GeneXpert® HIV-1 Quant assay (a point-of-care technology) in view of scaling up HIV-1 viral load in India to monitor the success of national ART programme was carried out. Two hundred nineteen plasma specimens falling in nine viral load ranges (5 L copies/ml) were tested by the Abbott m2000rt Real Time and GeneXpert HIV-1 Quant assays. Additionally, 20 seronegative; 16 stored specimens and 10 spiked controls were also tested. Statistical analysis was done using Stata/IC and sensitivity, specificity, PPV, NPV and %misclassification rates were calculated as per DHSs/AISs, WHO, NACO cut-offs for virological failure. The GeneXpert assay compared well with the Abbott assay with a higher sensitivity (97%), specificity (97-100%) and concordance (91.32%). The correlation between two assays (r = 0.886) was statistically significant (p performance and rapidity will aid in timely diagnosis of ART failures, integrated HIV-TB management and will facilitate the UNAIDS 90-90-90 target.

  11. 21 CFR 878.4635 - Ultraviolet lamp for tanning.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultraviolet lamp for tanning. 878.4635 Section 878... tanning. (a) Identification. An ultraviolet lamp for tanning is a device that is a lamp (including a fixture) intended to provide ultraviolet radiation to tan the skin. See § 1040.20 of this chapter. (b...

  12. Demixing in a metal halide lamp, results from modelling

    NARCIS (Netherlands)

    Beks, M.L.; Hartgers, A.; Mullen, van der J.J.A.M.

    2006-01-01

    Convection and diffusion in the discharge region of a metal halide lamp is studied using a computer model built with the plasma modeling package Plasimo. A model lamp contg. mercury and sodium iodide is studied. The effects of the total lamp pressure on the degree of segregation of the light

  13. Influence of Voltage on Main Characteristics of Electric Lighting Lamps

    Directory of Open Access Journals (Sweden)

    V. B. Kozlovskaya

    2009-01-01

    Full Text Available An analysis and systemization of data on influence of voltage value on main lighting engineering, electric and economic characteristics of incandescent lamps, gaseous-discharge lamps of low and high pressure have been made in the paper.Analytical and graphical dependences have been obtained that ensure to evaluate quantitative changes of corresponding lamp characteristics at voltage deviation from nominal value.

  14. Electrodeless discharge lamp is easily started, has high stability

    Science.gov (United States)

    Bell, W. E.; Bloom, A. L.

    1966-01-01

    Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

  15. Definition of a high intensity metal halide discharge reference lamp

    NARCIS (Netherlands)

    Stoffels, W.W.; Baede, A.H.F.M.; Mullen, van der J.J.A.M.; Haverlag, M.; Zissis, G.

    2006-01-01

    The design of a ref. metal halide discharge lamp is presented. This lamp is meant as a common study object for researchers working on metal halide discharge lamps, who by using the same design will be able to compare results between research groups, diagnostic techniques and numerical models. The

  16. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  17. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type where they are exposed to...

  18. Analysis of the performance of domestic lighting lamps

    International Nuclear Information System (INIS)

    Aman, M.M.; Jasmon, G.B.; Mokhlis, H.; Bakar, A.H.A.

    2013-01-01

    The power crisis problem is getting worse in the developing countries. Measures are being taken to overcome the power shortage problem by efficiently utilizing the available power. Replacement of high-power consumption lamps with energy efficient lamps is also among these steps. This paper presents a detailed comparative analysis between domestic lighting lamps (DLLs) use for producing artificial light. DLLs include incandescent lamp (IL), fluorescent lamp (FL) and compact fluorescent lamp (CFL). Light emitting diodes (LED) based lamp technology is relatively new in comparison with conventional incandescent and discharge lamps. However, the present study will also cover the LED lamps. Power quality based experiments have been conducted on DLLs in Power System Laboratory and power consumption based calculations are carried out using the lighting design software DIALux. The result shows that with the current technology, the use of FL and LED lamp is beneficial for utility as well as for consumer. However, with the current pace in the development of LED technology, it is possible LED lamps will lead the lighting market in the near future. The paper has also presented the uncertainties that exist in lighting market and proposed the guidelines that will help in making future energy policy. - Highlights: ► Performances of domestic lighting lamps are compared. ► Power quality and power consumption based case study results are presented. ► For future energy policies, recommendations are also given.

  19. 30 CFR 75.1703 - Portable electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...

  20. 47 CFR 17.54 - Rated lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... voltage. To insure the necessary lumen output by obstruction lights, the rated voltage of incandescent lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  1. Evaluation of three sampling methods to monitor outcomes of antiretroviral treatment programmes in low- and middle-income countries.

    Science.gov (United States)

    Tassie, Jean-Michel; Malateste, Karen; Pujades-Rodríguez, Mar; Poulet, Elisabeth; Bennett, Diane; Harries, Anthony; Mahy, Mary; Schechter, Mauro; Souteyrand, Yves; Dabis, François

    2010-11-10

    Retention of patients on antiretroviral therapy (ART) over time is a proxy for quality of care and an outcome indicator to monitor ART programs. Using existing databases (Antiretroviral in Lower Income Countries of the International Databases to Evaluate AIDS and Médecins Sans Frontières), we evaluated three sampling approaches to simplify the generation of outcome indicators. We used individual patient data from 27 ART sites and included 27,201 ART-naive adults (≥15 years) who initiated ART in 2005. For each site, we generated two outcome indicators at 12 months, retention on ART and proportion of patients lost to follow-up (LFU), first using all patient data and then within a smaller group of patients selected using three sampling methods (random, systematic and consecutive sampling). For each method and each site, 500 samples were generated, and the average result was compared with the unsampled value. The 95% sampling distribution (SD) was expressed as the 2.5(th) and 97.5(th) percentile values from the 500 samples. Overall, retention on ART was 76.5% (range 58.9-88.6) and the proportion of patients LFU, 13.5% (range 0.8-31.9). Estimates of retention from sampling (n = 5696) were 76.5% (SD 75.4-77.7) for random, 76.5% (75.3-77.5) for systematic and 76.0% (74.1-78.2) for the consecutive method. Estimates for the proportion of patients LFU were 13.5% (12.6-14.5), 13.5% (12.6-14.3) and 14.0% (12.5-15.5), respectively. With consecutive sampling, 50% of sites had SD within ±5% of the unsampled site value. Our results suggest that random, systematic or consecutive sampling methods are feasible for monitoring ART indicators at national level. However, sampling may not produce precise estimates in some sites.

  2. NNP Life Management Programmes

    International Nuclear Information System (INIS)

    Hervia Ruperez, F.

    1996-01-01

    Around the world, power station owners are increasingly concerned to optimise Plant Life Management. In response, they are setting up Life Management programmes, of more or less ambitious scope and depth. Strategic, economic and security concerns and the close link between life extension work and the improved maintenance practices that are so important today, will increase and global these programmes for monitoring and conservation or mitigation of ageing. These programmes are all based on knowledge of the precise condition of all components and population with the greatest effect on the economics and safety of the plant, and trends in changes in their condition. (Author)

  3. CALiPER Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-31

    This CALiPER report examines the characteristics of a subset of lamps from CALiPER Retail Lamps Study 3 in more detail. Specifically, it focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers.

  4. Shining a light on LAMP assays--a comparison of LAMP visualization methods including the novel use of berberine.

    Science.gov (United States)

    Fischbach, Jens; Xander, Nina Carolin; Frohme, Marcus; Glökler, Jörn Felix

    2015-04-01

    The need for simple and effective assays for detecting nucleic acids by isothermal amplification reactions has led to a great variety of end point and real-time monitoring methods. Here we tested direct and indirect methods to visualize the amplification of potato spindle tuber viroid (PSTVd) by loop-mediated isothermal amplification (LAMP) and compared features important for one-pot in-field applications. We compared the performance of magnesium pyrophosphate, hydroxynaphthol blue (HNB), calcein, SYBR Green I, EvaGreen, and berberine. All assays could be used to distinguish between positive and negative samples in visible or UV light. Precipitation of magnesium-pyrophosphate resulted in a turbid reaction solution. The use of HNB resulted in a color change from violet to blue, whereas calcein induced a change from orange to yellow-green. We also investigated berberine as a nucleic acid-specific dye that emits a fluorescence signal under UV light after a positive LAMP reaction. It has a comparable sensitivity to SYBR Green I and EvaGreen. Based on our results, an optimal detection method can be chosen easily for isothermal real-time or end point screening applications.

  5. Improvements on an ELISA to detect trypanosomal antigens and its use as a monitoring tool in tsetse and trypanosomosis control programmes

    Energy Technology Data Exchange (ETDEWEB)

    Dwinger, R H; Rebeski, D; Winger, E [Joint FAO/IAEA Div. of Nuclear Techniques in Food and Agriculture, Vienna (Austria). Animal Production and Health Section

    1997-02-01

    Monoclonal antibodies directed at epitopes of Trypanosoma brucei, T. congolense and T. vivax have been used to capture and detect trypanosomal antigens in bovine blood samples using an enzyme-linked immunosorbent assay (ELISA) developed elsewhere. The test has been transformed in a ready-to-use kit format for distribution among a network of 15 African research institutes. The specificity of the test was assessed under experimental and field conditions and found to be 96% ({+-} 2%) for T. brucei, 99.5% ({+-}1%) for T. congolense and 99% ({+-}1%) for T. vivax. Following a validation period under field conditions, adjustments were made to the protocol to increase the sensitivity of the ELISA and to improve the suitability of the test for laboratory use under African conditions. Presently the ag-ELISA is being applied in conjunction with conventional parasitological techniques such as the buffy coat technique (BCT) to monitor progress in various tsetse and trypanosomosis control programmes and in a tsetse eradication effort on the island of Zanzibar. The two tests complement each other; the serological test tends to produce more false negatives during subacute infections, while the parasitological techniques tend to produce more false negatives during chronic infections. Since the sensitivity of the ELISA is not optimal, research efforts at the FAO/IAEA Agriculture and Biotechnology Laboratory will be focused on improving this aspect. However, these efforts are severely hampered by the lack of a diagnostic test that can be used as a ``gold standard``. The use of the polymerase chain reaction for verifying doubtful test results and as a possible candidate for a ``gold standard`` to diagnose trypanosomosis are discussed. Finally, future plans are outlined to initiate the use of geographical information systems to assess the impact of tsetse control and eradication programmes on land use and disease distribution. (author). 8 refs.

  6. Improvements on an ELISA to detect trypanosomal antigens and its use as a monitoring tool in tsetse and trypanosomosis control programmes

    International Nuclear Information System (INIS)

    Dwinger, R.H.; Rebeski, D.; Winger, E.

    1997-01-01

    Monoclonal antibodies directed at epitopes of Trypanosoma brucei, T. congolense and T. vivax have been used to capture and detect trypanosomal antigens in bovine blood samples using an enzyme-linked immunosorbent assay (ELISA) developed elsewhere. The test has been transformed in a ready-to-use kit format for distribution among a network of 15 African research institutes. The specificity of the test was assessed under experimental and field conditions and found to be 96% (± 2%) for T. brucei, 99.5% (±1%) for T. congolense and 99% (±1%) for T. vivax. Following a validation period under field conditions, adjustments were made to the protocol to increase the sensitivity of the ELISA and to improve the suitability of the test for laboratory use under African conditions. Presently the ag-ELISA is being applied in conjunction with conventional parasitological techniques such as the buffy coat technique (BCT) to monitor progress in various tsetse and trypanosomosis control programmes and in a tsetse eradication effort in the United Republic of Tanzania, on the island of Zanzibar. The two tests complement each other, since infections not detected by one test may be detected by the other. In general, the serological test tends to produce more false negatives during subacute infections, while the parasitological techniques tend to produce more false negatives during chronic infections. Since the sensitivity of the ELISA is not optimal, research efforts at the FAO/IAEA Agriculture and Biotechnology Laboratory will be focused on improving this aspect. However, these efforts are severely hampered by the lack of a diagnostic test that can be used as a ''gold standard''. The use of the polymerase chain reaction for verifying doubtful test results and as a possible candidate for a ''gold standard'' to diagnose trypanosomosis are discussed. Finally, future plans are outlined to initiate the use of geographical information systems to assess the impact of tsetse control and

  7. Treating high-mercury-containing lamps using full-scale thermal desorption technology.

    Science.gov (United States)

    Chang, T C; You, S J; Yu, B S; Chen, C M; Chiu, Y C

    2009-03-15

    The mercury content in high-mercury-containing lamps are always between 400 mg/kg and 200,000 mg/kg. This concentration is much higher than the 260 mg/kg lower boundary recommended for the thermal desorption process suggested by the US Resource Conservation and Recovery Act. According to a Taiwan EPA survey, about 4,833,000 cold cathode fluorescent lamps (CCFLs), 486,000 ultraviolet lamps and 25,000 super high pressure mercury lamps (SHPs) have been disposed of in the industrial waste treatment system, producing 80, 92 and 9 kg-mercury/year through domestic treatment, offshore treatment and air emissions, respectively. To deal with this problem we set up a full-scale thermal desorption process to treat and recover the mercury from SHPs, fluorescent tube tailpipes, fluorescent tubes containing mercury-fluorescent powder, and CCFLs containing mercury-fluorescent powder and monitor the use of different pre-heating temperatures and desorption times. The experimental results reveal that the average thermal desorption efficiency of SHPs and fluorescent tube tailpipe were both 99.95%, while the average thermal desorption efficiencies of fluorescent tubes containing mercury-fluorescent powder were between 97% and 99%. In addition, a thermal desorption efficiency of only 69.37-93.39% was obtained after treating the CCFLs containing mercury-fluorescent powder. These differences in thermal desorption efficiency might be due to the complexity of the mercury compounds contained in the lamps. In general, the thermal desorption efficiency of lamps containing mercury-complex compounds increased with higher temperatures.

  8. The high pressure xenon lamp as a source of radiation

    International Nuclear Information System (INIS)

    Heerdt, J.A. ter.

    1979-01-01

    An account is given of an investigation into the radiation properties of a commercially available high pressure xenon lamp (type XBO 900 W) in the spectral range 0.3 to 3 μm. The purpose of the study was to find out whether such a lamp can serve as a (secondary) standard of radiation in spectroscopic and radiometric measurements. The main advantades of the xenon lamp over other secondary standards such as the tungsten strip lamp and the anode of a carbon arc lamp are the high temperature of its discharge and the resulting strong radiation over a broad spectral range. (Auth.)

  9. [Remote Slit Lamp Microscope Consultation System Based on Web].

    Science.gov (United States)

    Chen, Junfa; Zhuo, Yong; Liu, Zuguo; Chen, Yanping

    2015-11-01

    To realize the remote operation of the slit lamp microscope for department of ophthalmology consultation, and visual display the real-time status of remote slit lamp microscope, a remote slit lamp microscope consultation system based on B/S structure is designed and implemented. Through framing the slit lamp microscope on the website system, the realtime acquisition and transmission of remote control and image data is realized. The three dimensional model of the slit lamp microscope is established and rendered on the web by using WebGL technology. The practical application results can well show the real-time interactive of the remote consultation system.

  10. The Video Collaborative Localization of a Miner’s Lamp Based on Wireless Multimedia Sensor Networks for Underground Coal Mines

    Directory of Open Access Journals (Sweden)

    Kaiming You

    2015-09-01

    Full Text Available Based on wireless multimedia sensor networks (WMSNs deployed in an underground coal mine, a miner’s lamp video collaborative localization algorithm was proposed to locate miners in the scene of insufficient illumination and bifurcated structures of underground tunnels. In bifurcation area, several camera nodes are deployed along the longitudinal direction of tunnels, forming a collaborative cluster in wireless way to monitor and locate miners in underground tunnels. Cap-lamps are regarded as the feature of miners in the scene of insufficient illumination of underground tunnels, which means that miners can be identified by detecting their cap-lamps. A miner’s lamp will project mapping points on the imaging plane of collaborative cameras and the coordinates of mapping points are calculated by collaborative cameras. Then, multiple straight lines between the positions of collaborative cameras and their corresponding mapping points are established. To find the three-dimension (3D coordinate location of the miner’s lamp a least square method is proposed to get the optimal intersection of the multiple straight lines. Tests were carried out both in a corridor and a realistic scenario of underground tunnel, which show that the proposed miner’s lamp video collaborative localization algorithm has good effectiveness, robustness and localization accuracy in real world conditions of underground tunnels.

  11. The Video Collaborative Localization of a Miner's Lamp Based on Wireless Multimedia Sensor Networks for Underground Coal Mines.

    Science.gov (United States)

    You, Kaiming; Yang, Wei; Han, Ruisong

    2015-09-29

    Based on wireless multimedia sensor networks (WMSNs) deployed in an underground coal mine, a miner's lamp video collaborative localization algorithm was proposed to locate miners in the scene of insufficient illumination and bifurcated structures of underground tunnels. In bifurcation area, several camera nodes are deployed along the longitudinal direction of tunnels, forming a collaborative cluster in wireless way to monitor and locate miners in underground tunnels. Cap-lamps are regarded as the feature of miners in the scene of insufficient illumination of underground tunnels, which means that miners can be identified by detecting their cap-lamps. A miner's lamp will project mapping points on the imaging plane of collaborative cameras and the coordinates of mapping points are calculated by collaborative cameras. Then, multiple straight lines between the positions of collaborative cameras and their corresponding mapping points are established. To find the three-dimension (3D) coordinate location of the miner's lamp a least square method is proposed to get the optimal intersection of the multiple straight lines. Tests were carried out both in a corridor and a realistic scenario of underground tunnel, which show that the proposed miner's lamp video collaborative localization algorithm has good effectiveness, robustness and localization accuracy in real world conditions of underground tunnels.

  12. The Video Collaborative Localization of a Miner’s Lamp Based on Wireless Multimedia Sensor Networks for Underground Coal Mines

    Science.gov (United States)

    You, Kaiming; Yang, Wei; Han, Ruisong

    2015-01-01

    Based on wireless multimedia sensor networks (WMSNs) deployed in an underground coal mine, a miner’s lamp video collaborative localization algorithm was proposed to locate miners in the scene of insufficient illumination and bifurcated structures of underground tunnels. In bifurcation area, several camera nodes are deployed along the longitudinal direction of tunnels, forming a collaborative cluster in wireless way to monitor and locate miners in underground tunnels. Cap-lamps are regarded as the feature of miners in the scene of insufficient illumination of underground tunnels, which means that miners can be identified by detecting their cap-lamps. A miner’s lamp will project mapping points on the imaging plane of collaborative cameras and the coordinates of mapping points are calculated by collaborative cameras. Then, multiple straight lines between the positions of collaborative cameras and their corresponding mapping points are established. To find the three-dimension (3D) coordinate location of the miner’s lamp a least square method is proposed to get the optimal intersection of the multiple straight lines. Tests were carried out both in a corridor and a realistic scenario of underground tunnel, which show that the proposed miner’s lamp video collaborative localization algorithm has good effectiveness, robustness and localization accuracy in real world conditions of underground tunnels. PMID:26426023

  13. Factors affecting 210Po and 210Pb activity concentrations in mussels and implications for environmental bio-monitoring programmes

    International Nuclear Information System (INIS)

    Carvalho, Fernando P.; Oliveira, Joao M.; Alberto, G.

    2011-01-01

    The activity of 210 Po and 210 Pb was determined in mussels of the same size (3.5-4.0 cm shell length) sampled monthly over a 17-month period at the Atlantic coast of Portugal. Average radionuclide concentration values in mussels were 759 ± 277 Bq kg -1 for 210 Po (range 460-1470 Bq kg -1 dry weight), and 45 ± 19 Bq kg -1 for 210 Pb (range 23-96 Bq kg -1 dry weight). Environmental parameters and mussel biometric parameters were monitored during the same period. Although there was no seasonal variation of radionuclide concentrations in sea water during the study period, the concentration of radionuclide activity in mussels varied seasonally displaying peaks of high concentrations in winter and low concentrations in summer. Analysis of radionuclide data in relation to the physiological Condition Index of mussels revealed that 210 Po and 210 Pb activities in the mussel (average activity per individual) remained nearly constant during the investigation period, while mussel body weight fluctuated due to fat storage/expenditure in the soft tissues. Similar variation of radionuclide concentrations was observed in mussels transplanted from the sea coast into the Tejo Estuary. However, under estuarine environmental conditions and with higher food availability throughout the year, transplanted mussel Condition Index was higher than in coastal mussels and average radionuclide concentrations were 210 ± 75 Bq kg -1 (dry weight) for 210 Po and 10 ± 4 Bq kg -1 (dry weight) for 210 Pb, therefore lower than in coastal mussels with similar shell length. It is concluded that the apparent seasonal fluctuation and inter-site difference of radionuclide concentrations were mostly caused by mussel body weight fluctuation and not by radionuclide body burden fluctuation. This interpretation can be extended to the apparent seasonal fluctuation in concentrations of lipophilic and lipophobic contaminants in mussels, and provides an explanation for occasional high concentrations of 210 Po

  14. GMO detection using a bioluminescent real time reporter (BART of loop mediated isothermal amplification (LAMP suitable for field use

    Directory of Open Access Journals (Sweden)

    Kiddle Guy

    2012-04-01

    Full Text Available Abstract Background There is an increasing need for quantitative technologies suitable for molecular detection in a variety of settings for applications including food traceability and monitoring of genetically modified (GM crops and their products through the food processing chain. Conventional molecular diagnostics utilising real-time polymerase chain reaction (RT-PCR and fluorescence-based determination of amplification require temperature cycling and relatively complex optics. In contrast, isothermal amplification coupled to a bioluminescent output produced in real-time (BART occurs at a constant temperature and only requires a simple light detection and integration device. Results Loop mediated isothermal amplification (LAMP shows robustness to sample-derived inhibitors. Here we show the applicability of coupled LAMP and BART reactions (LAMP-BART for determination of genetically modified (GM maize target DNA at low levels of contamination (0.1-5.0% GM using certified reference material, and compare this to RT-PCR. Results show that conventional DNA extraction methods developed for PCR may not be optimal for LAMP-BART quantification. Additionally, we demonstrate that LAMP is more tolerant to plant sample-derived inhibitors, and show this can be exploited to develop rapid extraction techniques suitable for simple field-based qualitative tests for GM status determination. We also assess the effect of total DNA assay load on LAMP-BART quantitation. Conclusions LAMP-BART is an effective and sensitive technique for GM detection with significant potential for quantification even at low levels of contamination and in samples derived from crops such as maize with a large genome size. The resilience of LAMP-BART to acidic polysaccharides makes it well suited to rapid sample preparation techniques and hence to both high throughput laboratory settings and to portable GM detection applications. The impact of the plant sample matrix and genome loading

  15. Operational feasibility of lot quality assurance sampling (LQAS) as a tool in routine process monitoring of filariasis control programmes.

    Science.gov (United States)

    Vanamail, P; Subramanian, S; Srividya, A; Ravi, R; Krishnamoorthy, K; Das, P K

    2006-08-01

    Lot quality assurance sampling (LQAS) with two-stage sampling plan was applied for rapid monitoring of coverage after every round of mass drug administration (MDA). A Primary Health Centre (PHC) consisting of 29 villages in Thiruvannamalai district, Tamil Nadu was selected as the study area. Two threshold levels of coverage were used: threshold A (maximum: 60%; minimum: 40%) and threshold B (maximum: 80%; minimum: 60%). Based on these thresholds, one sampling plan each for A and B was derived with the necessary sample size and the number of allowable defectives (i.e. defectives mean those who have not received the drug). Using data generated through simple random sampling (SRSI) of 1,750 individuals in the study area, LQAS was validated with the above two sampling plans for its diagnostic and field applicability. Simultaneously, a household survey (SRSH) was conducted for validation and cost-effectiveness analysis. Based on SRSH survey, the estimated coverage was 93.5% (CI: 91.7-95.3%). LQAS with threshold A revealed that by sampling a maximum of 14 individuals and by allowing four defectives, the coverage was >or=60% in >90% of villages at the first stage. Similarly, with threshold B by sampling a maximum of nine individuals and by allowing four defectives, the coverage was >or=80% in >90% of villages at the first stage. These analyses suggest that the sampling plan (14,4,52,25) of threshold A may be adopted in MDA to assess if a minimum coverage of 60% has been achieved. However, to achieve the goal of elimination, the sampling plan (9, 4, 42, 29) of threshold B can identify villages in which the coverage is LQAS are more cost-effective than SRSH to detect a village with a given level of coverage. The cost per village was US dollars 76.18 under SRSH. The cost of LQAS was US dollars 65.81 and 55.63 per village for thresholds A and B respectively. The total financial cost of classifying a village correctly with the given threshold level of LQAS could be reduced by

  16. LED lamp color control system and method

    Science.gov (United States)

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

    2013-02-05

    An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

  17. Monitoring Salmonella, Campylobacter, Escherichia coli and Staphylococcus aureus in traditional free-range 'Label Rouge' broiler production: a 23-year survey programme.

    Science.gov (United States)

    Salvat, G; Guyot, M; Protino, J

    2017-01-01

    'Label Rouge' broiler free-range carcasses have been monitored since 1991, and broiler flocks since 2010, for contamination by the main foodborne zoonotic bacteria. Initially, the monitoring plan mainly focused on the surveillance of Salmonella, and on indicators of the overall microbiological quality of free-range broiler carcasses such as Staphylococcus aureus and coliforms, but was extended in 2007 to include Campylobacter enumeration on carcasses and in 2010, to Salmonella in the environment of live birds. Salmonella contamination of free-range broiler carcasses rose to a peak of 16% in 1994 but less than 1% of carcasses are now regularly found to be positive. Indicators of the overall microbiological quality of carcasses are also improving. These results correlate with the low prevalence of Salmonella in free-range broiler breeding and production flocks, and with the continuous improvement of hazard analysis and critical control points in slaughterhouses, the implementation of a good manufacturing practice guide since 1997 and the application of EU regulations on Salmonella since 1998 in France. Regarding Campylobacter counts on carcasses, the situation has been improving continuously over the last few years, even if 2·5% of the carcasses are still contaminated by more than 1000 Campylobacter per g of skin. Although the current control system focusing on Salmonella is based on firm epidemiologic data and offers effective means of control (e.g. slaughtering of positive breeder flocks), existing information on Campylobacter makes it more difficult to formulate an effective control plan for free-range broilers, due to their particular exposure to environmental contamination. This long-term surveillance programme provided an extended view of the evolution of the contamination of free-range broilers and a direct measurement of the impact of mandatory and profession-driven interventions on the microbiological quality of carcasses. © 2016 The Society for Applied

  18. CALiPER Retail Lamps Study 3

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-02-01

    This is a special CALiPER report on LED lamps available through the retail marketplace and targeted toward general consumers. It follows similar reports published in 2011 and 2012 (products purchased in 2010 and 2011), and is intended as a continuation that identifies long-term trends. For this report, products were selected to investigate specific hypotheses, rather than represent a sample of the increasingly large retail LED market.

  19. UVR: sun, lamps, pigmentation and vitamin D

    DEFF Research Database (Denmark)

    Lerche, C M; Philipsen, P A; Wulf, H C

    2017-01-01

    Exposure to ultraviolet radiation (UVR) has important and significant consequences on human health. Recently, there has been renewed interest in the beneficial effects of UVR. This perspective gives an introduction to the solar spectrum, UV lamps, UV dosimetry, skin pigment and vitamin D....... The health benefits of UVR exposure through vitamin D production or non-vitamin D pathways will be discussed in this themed issue in the following articles....

  20. Rapid instrumental and separation methods for monitoring radionuclides in food and environmental samples. Final report on an IAEA co-ordinated research programme

    International Nuclear Information System (INIS)

    1995-01-01

    The Co-ordinated Research Programme (CRP) on Rapid Instrumental and Separation Methods for Monitoring Radionuclides in Food and Environmental Samples was established by the Agency following a Consultants' Meeting on the same topic, which was held 5-9 September 1988 in Vienna. It was completed in 1992. At various times during its course it encompassed 15 participants from 14 countries. The scope of work and objectives of the CRP were established at the Consultants' Meeting. It was agreed that the CRP should focus on the development of rapid methods for the determination of radionuclides in food and environmental samples during the intermediate and late post-accident phases. The rapid methods developed during the course of the CRP were intended to permit a timely and accurate determination of radionuclides at concentrations at least one order of magnitude below those specified for Derived Intervention Levels (DILs) for food by the WHO/FAO and the IAEA. Research Co-ordination meetings were held in Warsaw, Poland in September 1989 and in Vienna, Austria in 1991. Reports of the meetings are available from the Agency on Request. This document comprises copies of final reports from the participants and selected contributions presented by the participants at the meetings. The contributions were selected on the basis of being able to stand alone, without further explanation. Where there was an overlap in the information presented by a participant at both meetings, the most complete contribution was selected

  1. Rapid instrumental and separation methods for monitoring radionuclides in food and environmental samples. Final report on an IAEA co-ordinated research programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Co-ordinated Research Programme (CRP) on Rapid Instrumental and Separation Methods for Monitoring Radionuclides in Food and Environmental Samples was established by the Agency following a Consultants' Meeting on the same topic, which was held 5-9 September 1988 in Vienna. It was completed in 1992. At various times during its course it encompassed 15 participants from 14 countries. The scope of work and objectives of the CRP were established at the Consultants' Meeting. It was agreed that the CRP should focus on the development of rapid methods for the determination of radionuclides in food and environmental samples during the intermediate and late post-accident phases. The rapid methods developed during the course of the CRP were intended to permit a timely and accurate determination of radionuclides at concentrations at least one order of magnitude below those specified for Derived Intervention Levels (DILs) for food by the WHO/FAO and the IAEA. Research Co-ordination meetings were held in Warsaw, Poland in September 1989 and in Vienna, Austria in 1991. Reports of the meetings are available from the Agency on Request. This document comprises copies of final reports from the participants and selected contributions presented by the participants at the meetings. The contributions were selected on the basis of being able to stand alone, without further explanation. Where there was an overlap in the information presented by a participant at both meetings, the most complete contribution was selected.

  2. Raman lidar characterization using a reference lamp

    Science.gov (United States)

    Landulfo, Eduardo; da Costa, Renata F.; Rodrigues, Patricia F.; da Silva Lopes, Fábio J.

    2014-10-01

    The determination of the amount of water vapor in the atmosphere using lidar is a calibration dependent technique. Different collocated instruments are used for this purpose, like radiossoundings and microwave radiometers. When there are no collocated instruments available, an independente lamp mapping calibration technique can be used. Aiming to stabilish an independ technique for the calibration of the six channels Nd-YAG Raman lidar system located at the Center for Lasers and Applications (CLA), S˜ao Paulo, Brazil, an optical characterization of the system was first performed using a reference tungsten lamp. This characterization is useful to identify any possible distortions in the interference filters, telescope mirror and stray light contamination. In this paper we show three lamp mapping caracterizations (01/16/2014, 01/22/2014, 04/09/2014). The first day is used to demostrate how the tecnique is useful to detect stray light, the second one how it is sensible to the position of the filters and the third one demostrates a well optimized optical system.

  3. Light and Light Sources High-Intensity Discharge Lamps

    CERN Document Server

    Flesch, Peter G

    2006-01-01

    Light and Light Sources gives an introduction to the working principles of high-intensity discharge (HID) lamps and points out challenges and problems associated with the development and operation of HID lamps. The state-of-the-art in electrode and plasma diagnostics as well as numerical methods used for the understanding of HID lamps are described. This volume addresses students as well as scientists and researchers at universities and in industry.

  4. Ultraviolet radiation levels associated with the use of fluorescent general lighting, UV-A and UV-B lamps in the workplace and home

    International Nuclear Information System (INIS)

    Whillock, M.; Clark, I.E.; McKinlay, A.F.; Todd, C.D.; Mundy, S.J.

    1988-09-01

    A detailed programme of measurements was undertaken by NRPB to determine the ultraviolet irradiance levels likely to be encountered in the workplace and in the home, where fluorescent lighting is used. Assessments have been made of the possible potential risk of the induction of acute effects (photokeratitis, erythema) and of inducing malignant melanoma and non-malignant melanoma skin cancers resulting from exposure to commonly used fluorescent lamps. The optical absorption properties of materials commonly used in diffusers and controllers in commercial and domestic lighting units were also measured. Irradiance data, both weighted (for biological effectiveness) and unweighted, for various lamp types are presented in the report, together with some typical spectral output distributions. The results show that at commonly used illumination levels the UVR emissions from general and special fluorescent lamps presented neither an acute nor a significant chronic hazard. High UV-B emission levels were measured from 'UV-B' lamps used in this study, and exposure to these lamps would result in acute injury within a short time. Great care should be taken in the use of these lamps, and advice should be provided to workers to ensure safe working conditions and procedures. (author)

  5. 10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.

    Science.gov (United States)

    2010-01-01

    ... high intensity discharge fixture, the efficiency of a lamp and ballast combination, expressed as a... lamps. Metal halide lamp means a high intensity discharge lamp in which the major portion of the light... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning metal halide lamp ballasts and...

  6. Sa uurisid ekspressionismi 1960ndatel ja 70ndatel... / Ene Lamp

    Index Scriptorium Estoniae

    Lamp, Ene

    2005-01-01

    2004. a. ilmunud raamatu "Ekspressionism" eest Eesti Kultuurkapitali suure kunstipreemia (100000 kr.) saanud Ene Lamp ekspressionismi tähenduse muutumiset, ekspressionismi rollist eesti kunstis, oma tulevikuplaanidest

  7. Promoting Literacy and Protection with Solar Lamps in Yemen

    Directory of Open Access Journals (Sweden)

    Jerry Farrell

    2014-04-01

    Full Text Available By distributing solar lamps to vulnerable rural women in Yemen, we promoted enrollment in literacy programs, as well as reading among their children. We saw a number of secondary benefits as well: safer households where dangerous kerosene lamps were used less frequently in the evening; a number of livelihood activities - cooking, husbandry, handicrafts - continued safely into evening hours; children found it easier to work on their homework using the solar powered lamps; and children found it easier and safer to walk in dark, rural streets in the evening with the solar lamps slung around their necks.

  8. Pulsed operation of high-pressure-sodium discharge lamps

    International Nuclear Information System (INIS)

    Guenther, K.; Kloss, H.G.; Lehmann, T.; Radtke, R.; Serick, F.

    1990-01-01

    Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.)

  9. Pulsed operation of high-pressure-sodium discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, K; Kloss, H G; Lehmann, T [Zentrum fuer Forschung und Technologie, Berlin (Germany, F.R.); Radtke, R; Serick, F [Zentralinstitut fuer Elektronenphysik, Berlin (Germany, F.R.)

    1990-01-01

    Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.).

  10. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    International Nuclear Information System (INIS)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-01-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×10 8 cm −2 s −1 to 10 14 cm −2 s −1 . The 202 Hg(n,γ) 203 Hg nuclear reaction was used for mercury mass evaluation. Activities of 203 Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg 2 Cl 2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps. - Highlights: • Mercury is an essential component of fluorescent lamps. • Fluorescent lamps were irradiated in neutron fields in research reactor. • 203 Hg induced radionuclide activity was measured using gamma spectrometry. • Mercury mass in fluorescent lamps can be measured by neutron activation analysis.

  11. Heat transfer assembly for a fluorescent lamp and fixture

    Science.gov (United States)

    Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

    1992-12-29

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

  12. Persistence of organophosphorus pesticides in aquatic environments. Coordinated programme on isotope-tracer-aided research and monitoring on agricultural residue - biological interactions in aquatic environment

    International Nuclear Information System (INIS)

    Horvath, L.

    1982-08-01

    A radiometric enzymic assay method was developed for quick measuring of organophosphorous insecticides in water samples. All steps of the assay procedure were carried out in scintillation vials. 50 μl enzyme solution (acetylcholinesterase of electric eel) and 50 μl buffer pH 7 were pipetted into the vial followed by 100 μl of water sample or aqueous solution of the insecticide and the mixture was incubated for 60 minutes. 50 μl 3 H-acetylcholine were added to the vial and the enzymic reaction stopped after 10 minutes by adding 200 μl buffer solution pH 2.5. 10 ml scintillation cocktail were then added and after shaking and 30 minutes standing the radioactivity was determined in a liquid scintillation spectrometer. Acetylcholine remained in the water phase while 3 H-acetic acid released in enzymic hydrolysis may be extracted by an organic solvent. By this method, not only the parent compound but also some of its degradation products, which possess some anticholinesteratic activity can be measured. The method is suitable for combination with thin-layer chromatography for identification purposes. Using this method, we studied the degradation of the organophosphorous insecticides malathion, parathion, DDVP and imidan. The degradation in distilled water and natural water was compared. For example, the half-time of malathion in distilled water at room temperature was 6 days while in natural water (Danube river) it was 4 hours. The degradation processes were also studied in model systems containing sediment and water. Degradation was faster in models containing solid particles than in filtered water. The radiometric enzymic method was tested as analytical procedure for residue monitoring. Since 1978 a residue monitoring programme was in progress in the Danube river near Budapest. Occasionally high residue levels were detected in spring and early summer. The radiometric enzymic method has proved to be a useful analytical method for anticholinesterase pesticides in

  13. Modelling the Dynamic Interaction Power System Lamp - Application to High Pressure Mercury Gas Discharge Lamps

    Directory of Open Access Journals (Sweden)

    ZIANE, M.

    2007-11-01

    Full Text Available The aim of this paper is to study the dynamic behaviour of a plant constituted by an electrical power system and a gas discharge lamp, this latter, increasingly used in street lighting, remains a nonlinear load element. Various approaches are used to represent it, one is the approximation of the discharge represented by a hot "channel", which verifies the assumption of local thermodynamic equilibrium [LTE] or the polynomial form of the conductance variation. A calculation procedure, based on "channel" approximation of the high pressure mercury (HPM gas-discharge lamp, is developed to determine the physical and electric magnitudes, which characterize the dynamic behavior of the couple "lamp-electrical power system". The evolution of the lamp properties when principal parameters of the discharge (pressure of mercury, voltage supply, frequency are varying were studied and analyzed. We show the concordance between simulation, calculations and measurements for electric, energetic or irradiative characteristics. The model reproduces well the evolution of properties of the supply when principal parameters of the discharge vary.

  14. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Energy Technology Data Exchange (ETDEWEB)

    Langhans, R.W. [Cornell Univ., Ithaca, NY (United States)

    1994-12-31

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. This report describes the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses. Growth Chambers are small (3m x 4/m and smaller) walk-in or reach-in enclosures with programmable, accurate temperature, relative humidity (RH) and irradiance control over wide ranges. The intent of growth chambers was to replicate sunlight conditions and transfer research results directly to the greenhouse or outside. It was realized that sunlight and outside conditions could not be mimicked. Growth chambers are also used to study irradiance and spectral fluxes. Growth Rooms are usually large rooms (larger than 3m x 4m) with only lamp irradiance, but providing relatively limited ranges of environmental control (i.e., 10 to 30 C temperature, 50 to 90% RH and ambient to 1000 ppm CO{sub 2}), and commonly independent of outside conditions. Irradiance requirements for growth rooms are similar to those of growth chambers. Growth rooms are also used for growing a large number of plants in a uniform standard environment condition and in commercial horticulture for tissue culture, seed germination (plugs) and seedling growth. Greenhouses are designed to allow maximum sunlight penetration through the structure. Initially greenhouses were used to extend the growing season. Then as heating systems, and cooling systems improved, they were used year round. Low light during the winter months reduced plant growth, but with the advent of efficient lamps (HID and fluorescent) it became possible to increase growth to rates close to that in summer months. Supplementary lighting is used during low light periods of the year and anytime to ensure consistent total daily irradiance for research plants.

  15. Reactor as furnace and reactor as lamp

    International Nuclear Information System (INIS)

    Goldanskii, V.I.

    1992-01-01

    There are presented general characteristics of the following ways of transforming of nuclear energy released in reactors into chemical : ordinary way (i.e. trough the heat, mechanical energy and electricity); chemonuclear synthesis ; use of high-temperature fuel elements (reactor as furnace); use of the mixed nγ-radiation of reactors; use of the radiation loops; radiation - photochemical synthesis (reactor as lamp). Advantage and disadvantages of all above variants are compared. The yield of the primary product of fixation of nitrogen (nitric oxide NO) in reactor with the high-temperature (above ca. 1900degC) fuel elements (reactor-furnace) can exceed W ∼ 200 kg per gram of burned uranium. For the latter variant (reactor-lamp) the yield of chemical products can reach W ∼ 60 kg. per gram of uranium. Such values of W are close to or even strongly exceed the yields of chemical products for other abovementioned variants and - what is particularly important - are not connected to the necessity of archscrupulous removal of radioactive contamination of products. (author)

  16. [Near infrared light irradiator using halogen lamp].

    Science.gov (United States)

    Ide, Yasuo

    2012-07-01

    The practical electric light bulb was invented by Thomas Alva Edison in 1879. Halogen lamp is the toughest and brightest electric light bulb. With light filter, it is used as a source of near infrared light. Super Lizer and Alphabeam are made as near infrared light irradiator using halogen lamp. The light emmited by Super Lizer is linear polarized near infrared light. The wave length is from 600 to 1,600 nm and strongest at about 1,000 nm. Concerning Super Lizer, there is evidence of analgesic effects and normalization of the sympathetic nervous system. Super Lizer has four types of probes. SG type is used for stellate ganglion irradiation. B type is used for narrow area irradiation. C and D types are for broad area irradiation. The output of Alphabeam is not polarized. The wave length is from 700 to 1,600 nm and the strongest length is about 1,000nm. Standard attachment is used for spot irradiation. Small attachment is used for stellate ganglion irradiation. Wide attachment is used for broad area irradiation. The effects of Alphabeam are thought to be similar to that of Super Lizer.

  17. Monitor resultaten geluid 2000

    NARCIS (Netherlands)

    Jabben J; Potma CJM; Swart WJR; LLO

    2001-01-01

    As part of an enhanced effort in monitoring the environmental quality in 1999, the RIVM set up a noise monitoring programme. This programme forms part of the project, "Development of a monitoring system for noise and disturbance", which aims at establishing a number of permanent sites for monitoring

  18. A loop-mediated isothermal amplification (LAMP assay for early detection of Schistosoma mansoni in stool samples: a diagnostic approach in a murine model.

    Directory of Open Access Journals (Sweden)

    Pedro Fernández-Soto

    2014-09-01

    Full Text Available Human schistosomiasis, mainly due to Schistosoma mansoni species, is one of the most prevalent parasitic diseases worldwide. To overcome the drawbacks of classical parasitological and serological methods in detecting S. mansoni infections, especially in acute stage of the disease, development of cost-effective, simple and rapid molecular methods is still needed for the diagnosis of schistosomiasis. A promising approach is the loop-mediated isothermal amplification (LAMP technology. Compared to PCR-based assays, LAMP has the advantages of reaction simplicity, rapidity, specificity, cost-effectiveness and higher amplification efficiency. Additionally, as results can be inspected by the naked eye, the technique has great potential for use in low-income countries.A sequence corresponding to a mitochondrial S. mansoni minisatellite DNA region was selected as a target for designing a LAMP-based method to detect S. mansoni DNA in stool samples. We used a S. mansoni murine model to obtain well defined stool and sera samples from infected mice with S. mansoni cercariae. Samples were taken weekly from week 0 to 8 post-infection and the Kato-Katz and ELISA techniques were used for monitoring the infection. Primer set designed were tested using a commercial reaction mixture for LAMP assay and an in house mixture to compare results. Specificity of LAMP was tested using 16 DNA samples from different parasites, including several Schistosoma species, and no cross-reactions were found. The detection limit of our LAMP assay (SmMIT-LAMP was 1 fg of S. mansoni DNA. When testing stool samples from infected mice the SmMIT-LAMP detected S. mansoni DNA as soon as 1 week post-infection.We have developed, for the first time, a cost-effective, easy to perform, specific and sensitive LAMP assay for early detection of S. mansoni in stool samples. The method is potentially and readily adaptable for field diagnosis and disease surveillance in schistosomiasis-endemic areas.

  19. Development of Loop-Mediated Isothermal Amplification (LAMP) assay for rapid detection of Fusarium oxysporum f. sp. ciceris - wilt pathogen of chickpea.

    Science.gov (United States)

    Ghosh, Raju; Nagavardhini, Avuthu; Sengupta, Anindita; Sharma, Mamta

    2015-02-11

    Fusarium oxysporum f. sp. ciceris (Foc), the causal agent of Fusarium wilt is a devastating pathogen of chickpea. In chickpea, various soil borne pathogens produce (s) similar symptoms, therefore cannot be distinguished easily at field level. There is real need for a rapid, inexpensive, and easy to operate and maintain genotyping tool to facilitate accurate disease diagnosis and surveillance for better management of Fusarium wilt outbreaks. In this study, we developed a loop-mediated isothermal amplification (LAMP) assay targeting the elongation factor 1 alpha gene sequence for visual detection of Foc. The LAMP reaction was optimal at 63°C for 60 min. When hydroxynaphthol blue (HNB) was added before amplification, samples with Foc DNA developed a characteristic sky blue colour but those without DNA or with the DNA of six other plant pathogenic fungi did not. Results obtained with LAMP and HNB were confirmed when LAMP products were subjected to gel electrophoresis. The detection limit of this LAMP assay for Foc was 10 fg of genomic DNA per reaction, while that of conventional PCR was 100 pg. In conclusion, it was found that a LAMP assay combined with HNB is simple, rapid, sensitive, and specific. The LAMP assay does not require specialized equipment, hence can be used in the field for the rapid detection of Foc. This is the first report of the use of LAMP assay for the detection of Foc. The presented LAMP method provides a specific, sensitive and rapid diagnostic tool for the distinction of Foc, with the potential to be standardized as a detection method for Foc in endemic areas and will be very useful for monitoring the disease complex in the field further suggesting the management strategies.

  20. Measurement of radionuclides in contaminated environmental matrices: participation in quality assessment programme of U.S. Department of energy's environmental monitoring laboratory

    International Nuclear Information System (INIS)

    SIDDIQUE, N.; Rahman, A.; Waheed, S.; Wasim, M.; Daud, M.; Ahmad, S.

    2006-03-01

    A Quality Assessment Programme (QAP) was initiated by the US, Department of Energy (DOE) in 1998 to establish credibility of radionuclide measurements in contaminated environmental samples, i.e. soil, vegetation and air filters. In this context best-known and pertinent laboratories around the world were identified and invited to participate in this programme. To evaluate the performance of these prestigious laboratories, the Miniature Neutron Source Reactor (MNSR) Neutron Activation Analysis (NAA) Laboratory at NCD, PINSTECH, which is an IAEA declared Regional Resource Unit (IAEA-RRU), along with 76 other laboratories were asked to take part in a regular proficiency exercise. In this report, the performance of the NAA Laboratory throughout the QAP programme (1998-2004) is presented is detail, describing the procedures employed, the problems encountered and the improvement and expertise gained from participating in this assessment programme. (author)

  1. Demixing in a metal halide lamp, results from modeling

    NARCIS (Netherlands)

    Beks, M.L.; Hartgers, A.; Mullen, van der J.J.A.M.; Veldhuizen, van E.M.

    2005-01-01

    Metal Halide (MH) lamps are high pressure discharge devices, containing a complex chemical mixture, to emit light on a broad spectrum while maintaining good efficacies. Lamps of this type were first exhibited by General Electric at the 1964 World Fair in New York [1]. They typically consist of an

  2. 49 CFR 393.11 - Lamps and reflective devices.

    Science.gov (United States)

    2010-10-01

    ... dolly obscures the turn signals at the rear of the towing vehicle. Footnote—6Pole trailers shall be... signals and the two rear signals to flash simultaneously as a vehicular traffic signal warning, required... vehicle, exclusive of the signal lamps, marker lamps, outside rearview mirrors, flexible fender extensions...

  3. High power solid state retrofit lamp thermal characterization and modeling

    NARCIS (Netherlands)

    Jakovenko, J.; Formánek, J.; Vladimír, J.; Husák, M.; Werkhoven, R.J.

    2012-01-01

    Thermal and thermo-mechanical modeling and characterization of solid state lightening (SSL) retrofit LED Lamp are presented in this paper. Paramount Importance is to design SSL lamps for reliability, in which thermal and thermo-mechanical aspects are key points. The main goal is to get a precise 3D

  4. Fluorescent lamp with static magnetic field generating means

    Science.gov (United States)

    Moskowitz, P.E.; Maya, J.

    1987-09-08

    A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

  5. Design of LED lamps | Ashryatov | Journal of Fundamental and ...

    African Journals Online (AJOL)

    Design of LED lamps. ... In this paper, we study the effect of LED high brightness on the brightness of a luminaire. The nomenclature of diffusers used in the production of ... The variant of the lighting system energy efficiency increase with luminaires and linear fluorescent lamps is considered. In the proposed variant, the ...

  6. Luminous flux and colour maintenance investigation of integrated LED lamps

    DEFF Research Database (Denmark)

    Corell, Dennis Dan; Thorseth, Anders; Dam-Hansen, Carsten

    2014-01-01

    This article will present an investigation of the luminous flux and colour maintenance of white LED based retrofit lamps. The study includes 23 different types of integrated LED lamps, covering 18 directional and 5 non-directional. Luminous flux and colour data for operation up to 20000 h has been...

  7. Thermal simulation and validation of 8W LED lamp

    NARCIS (Netherlands)

    Jakovenko, J.; Werkhoven, R.J.; Formánek, J.; Kunen, J.M.G.; Bolt, P.J.; Kulha, P.

    2011-01-01

    This work deals with thermal simulation and characterization of solid state lightening (SSL) LED Lamp in order to get precise 3D thermal models for further lamp thermal optimization. Simulations are performed with ANSYS-CFX and CoventorWare software tools. The simulated thermal distribution has been

  8. A new LED lamp for the collection of nocturnal Lepidoptera and a spectral comparison of light-trapping lamps

    Directory of Open Access Journals (Sweden)

    Gunnar Brehm

    2017-04-01

    Full Text Available Most nocturnal Lepidoptera can be attracted to artificial light sources, particularly to those that emit a high proportion of ultraviolet radiation. Here, I describe a newly developed LED lamp set for the use in the field that is lightweight, handy, robust, and energy efficient. The emitted electromagnetic spectrum corresponds to the peak sensitivity in most Lepidoptera eye receptors (ultraviolet, blue and green. Power LEDs with peaks at 368 nm (ultraviolet, 450 nm (blue, 530 nm (green, and 550 nm (cool white are used. I compared the irradiance (Ee of many commonly used light-trapping lamps at a distance of 50 cm. Between wavelengths of 300 and 1000 nm, irradiance from the new lamp was 1.43 W m-2. The new lamp proved to be the most energy efficient, and it emitted more radiation in the range between 300 and 400 nm than any other lamp tested. Cold cathodes are the second most energy-efficient lamps. Irradiation from fluorescent actinic tubes is higher than from fluorescent blacklight-blue tubes. High-wattage incandescent lamps and self-ballasted mercury vapour lamps have highest irradiance, but they mainly emit in the long wave spectrum. The use of gauze and sheets decreases the proportion of UV radiation and increases the share of blue light, probably due to optical brighteners. Compared with sunlight, UV irradiance is low at a distance of 50 cm from the lamp, but (safety glasses as well as keeping sufficient distance from the lamp are recommended. In field tests, the new LED lamp attracted large numbers of Lepidoptera in both the Italian Alps and in the Peruvian Andes.

  9. Crispv programme

    International Nuclear Information System (INIS)

    Marinkovicj, N.

    CRISPV (Criticality and Spectrum code) is a multigroup neutron spectrum code for homogeneous reactor cores and is actually a somewhat modified version of the original CRISP programme. It is a combination of DATAPREP-II and BIGG-II programmes. It is assumed that the reactor cell is a cylindrical fuel rod in the light or heavy water moderator. DATEPREP-II CODE forms the multigroup data for homogeneous reactor and prepares the input parameters for the BIGG-II code. It has its own nuclear data library on a separate tape in binary mode. BIGG-II code is a multigroup neutron spectrum and criticality code for a homogenized medium. It has as well its own separate data library. In the CRISPV programme the overlay structure enables automatic handling of data calculated in the DATAPREP-II programme and needed in the BIGG-II core. Both programmes are written in FORTRAN for CDC 3600. Using the programme is very efficient and simple

  10. Tanning lamps ultraviolet emissions and compliance with technical standards

    International Nuclear Information System (INIS)

    Bonino, A.; Facta, S.; Saudino, S.; Anglesio, L.; D'Amore, G.

    2009-01-01

    In this work the compliance of tanning lamps with technical standards EN 60335-2-27 'Household and similar electrical appliances-Safety. Part 2: Particular requirements for appliances for skin exposure to ultraviolet and infrared radiation' was analysed. Results of this analysis showed that none of the examined technical documentation produced by the lamps manufacturers is fully compliant with the standard technique. Furthermore data reported in the same manuals, such as effective radiant exposure or irradiance, would indicate that these sources may be the cause of undue exposure to ultraviolet (UV) radiation. For this reason a measurement campaign on UV lamps used in tanning salons was organised. The first results of these measurements seem to confirm the doubts raised from the analysis of the lamp manuals: the use of a tanning lamp can lead to UV radiation exposure levels higher than reference maximum values recommended by EN 60335-2-27. (authors)

  11. Ignition of mercury-free high intensity discharge lamps

    International Nuclear Information System (INIS)

    Czichy, M; Mentel, J; Awakowicz, P; Hartmann, T

    2008-01-01

    To achieve a better understanding of the ignition behaviour of D4 lamps for automotive headlights the ignition of mercury-free metal iodide test lamps characterized by a high xenon pressure, a small electrode distance and small electrode-wall distances is investigated. The ignition of these lamps is dominated by a high voltage requirement. Nevertheless lamps are found that show a surprisingly low ignition voltage. Electrical measurements and simultaneous optical observations of the ultra-fast streamer processes show that the breakdown takes place in two different modes. One of the ignition modes which requires a high ignition voltage is characterized by a breakdown in the volume between the electrode tips. The other mode is characterized by streamer discharges along the wall. In this case the cathode, its base and the wall around is involved in the ignition process and the lamp breaks down at low voltages

  12. Phase-resolved response of a metal-halide lamp

    International Nuclear Information System (INIS)

    Flikweert, A J; Beks, M L; Nimalasuriya, T; Kroesen, G M W; Van der Mullen, J J A M; Stoffels, W W

    2009-01-01

    The metal-halide (MH) lamp sometimes shows unwanted colour segregation, caused by a combination of convection and diffusion. In the past we investigated the lamp, running on a switched dc ballast of 120 Hz, using a dc approximation for the distribution of the radiating species. Here we present phase-resolved intensity measurements to verify this approximation. The MH lamp contains Hg as buffer gas and DyI 3 as salt additive; we measure the light emitted by Dy and by Hg atoms. An intensity fluctuation of ∼25% close to the electrodes is found only. The observed fluctuations are explained by the cataphoresis effect and temperature fluctuations; the time scales are in the same order. Furthermore, measurements at higher gravity in a centrifuge (up to 10g) show that the effect becomes smaller at increasing gravity levels. From these results it is concluded that a dc approximation, which is generally assumed by lamp developers, is allowed for this MH lamp.

  13. Processes and Technologies for the Recycling of Spent Fluorescent Lamps

    Directory of Open Access Journals (Sweden)

    Kujawski Wojciech

    2014-09-01

    Full Text Available The growing industrial application of rare earth metals led to great interest in the new technologies for the recycling and recovery of REEs from diverse sources. This work reviews the various methods for the recycling of spent fluorescent lamps. The spent fluorescent lamps are potential source of important rare earth elements (REEs such as: yttrium, terbium, europium, lanthanum and cerium. The characteristics of REEs properties and construction of typical fl uorescent lamps is described. The work compares also current technologies which can be utilized for an efficient recovery of REEs from phosphors powders coming from spent fluorescent lamps. The work is especially focused on the hydrometallurgical and pyrometallurgical processes. It was concluded that hydrometallurgical processes are especially useful for the recovery of REEs from spent fluorescent lamps. Moreover, the methods used for recycling of REEs are identical or very similar to those utilized for the raw ores processing.

  14. Monitoring community mobilisation and organisational capacity among high-risk groups in a large-scale HIV prevention programme in India: selected findings using a Community Ownership and Preparedness Index.

    Science.gov (United States)

    Narayanan, Pradeep; Moulasha, K; Wheeler, Tisha; Baer, James; Bharadwaj, Sowmyaa; Ramanathan, T V; Thomas, Tom

    2012-10-01

    In a participatory approach to health and development interventions, defining and measuring community mobilisation is important, but it is challenging to do this effectively, especially at scale. A cross-sectional, participatory monitoring tool was administered in 2008-2009 and 2009-2010 across a representative sample of 25 community-based groups (CBGs) formed under the Avahan India AIDS Initiative, to assess their progress in mobilisation, and to inform efforts to strengthen the groups and make them sustainable. The survey used a weighted index to capture both qualitative and quantitative data in numeric form. The index permitted broad, as well as highly detailed, analysis of community mobilisation, relevant at the level of individual groups, as well as state-wide and across the whole programme. The survey demonstrated that leadership and programme management were the strongest areas among the CBGs, confirming the programme's investment in these areas. Discussion of the Round 1 results led to efforts to strengthen governance and democratic decision making in the groups, and progress was reflected in the Round 2 survey results. CBG engagement with state authorities to gain rights and entitlements and securing the long-term financial stability of groups remain a challenge. The survey has proven useful for informing the managers of programmes about what is happening on the ground, and it has opened spaces for discussion within community groups about the nature of leadership, decision making and their goals, which is leading to accelerated progress. The tool provided useful data to manage community mobilisation in Avahan.

  15. Uranium vapor generator: pulsed hollow cathode lamp

    International Nuclear Information System (INIS)

    Carleer, M.; Gagne, J.; Leblanc, B.; Demers, Y.; Mongeau, B.

    1979-01-01

    The production of uranium vapors has been studied in the 5 L 0 6 ground state using a pulsed hollow cathode lamp. The evolution of the 238 U ( 5 L 0 6 ) concentration with time has been studied with Xe and Ar as buffer gases. A density of 2.7 x 10 13 atoms cm -3 was obtained with Xe as a buffer gas. In addition, those measurements, obtained from the absorption of a laser beam tuned to the 5758.143 A ( 5 L 0 6 -17,361 7 L 6 ) transition, allowed the determination of the transition probability A=2.1 x 10 5 sec -1 and of the branching ratio BR=0.08 for this transition

  16. Modelling the Dynamic Interaction Power System Lamp - Application to High Pressure Mercury Gas Discharge Lamps

    OpenAIRE

    ZIANE, M.; MEDLES, K.; ADJOUDJ, M.; MILOUA, F.; DAMELINCOURT, J. J.; TILMATINE, A.

    2007-01-01

    The aim of this paper is to study the dynamic behaviour of a plant constituted by an electrical power system and a gas discharge lamp, this latter, increasingly used in street lighting, remains a nonlinear load element. Various approaches are used to represent it, one is the approximation of the discharge represented by a hot "channel", which verifies the assumption of local thermodynamic equilibrium [LTE] or the polynomial form of the conductance variation. A calculation procedure, based on ...

  17. Application Summary Report 22: LED MR16 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P.

    2014-07-23

    This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens

  18. Ultraviolet radiation levels associated with the use of fluorescent general lighting, UV-A and UV-B lamps in the workplace and home

    CERN Document Server

    Whillock, M; MacKinlay, Alistair F; Mundy, S J; Todd, Carl David

    1988-01-01

    A detailed programme of measurements was undertaken by NRPB to determine the ultraviolet irradiance levels likely to be encountered in the workplace and in the home, where fluorescent lighting is used. Assessments have been made of the possible potential risk of the induction of acute effects (photokeratitis, erythema) and of inducing malignant melanoma and non-malignant melanoma skin cancers resulting from exposure to commonly used fluorescent lamps. The optical absorption properties of materials commonly used in diffusers and controllers in commercial and domestic lighting units were also measured. Irradiance data, both weighted (for biological effectiveness) and unweighted, for various lamp types are presented in the report, together with some typical spectral output distributions. The results show that at commonly used illumination levels the UVR emissions from general and special fluorescent lamps presented neither an acute nor a significant chronic hazard. High UV-B emission levels were measured from 'U...

  19. THE APPARATUS FOR ALIGNMENT OF THE PHOTOMETRIC LAMP FILAMENT

    Directory of Open Access Journals (Sweden)

    V. A. Dlugunovich

    2015-01-01

    Full Text Available During photometric measurements involving the use of photometric lamps it is necessary that the filament of lamp takes a strictly predetermined position with respect to the photodetector and the optical axis of the photometric setup. The errors in positioning of alignment filament with respect to the optical axis of the measuring system lead to increase the uncertainty of measurement of the photometric characteristics of the light sources. A typical method for alignment of filament of photometric lamps is based on the use a diopter tubes (telescopes. Using this method, the mounting of filament to the required position is carried out by successive approximations, which requires special concentration and a lot of time. The aim of this work is to develop an apparatus for alignment which allows simultaneous alignment of the filament of lamps in two mutually perpendicular planes. The method and apparatus for alignment of the photometric lamp filament during measurements of the photometric characteristics of light sources based on two digital video cameras is described in this paper. The apparatus allows to simultaneously displaying the image of lamps filament on the computer screen in two mutually perpendicular planes. The apparatus eliminates a large number of functional units requiring elementwise alignment and reduces the time required to carry out the alignment. The apparatus also provides the imaging of lamps filament with opaque coated on the bulb. The apparatus is used at the National standard of light intensity and illuminance units of the Republic of Belarus. 

  20. Microplasma light tiles: thin sheet lamps for general illumination

    Energy Technology Data Exchange (ETDEWEB)

    Eden, J G; Park, S-J [Laboratory for Optical Physics and Engineering, Department of Electrical and Computer Engineering, University of Illinois, Urbana, IL 61801 (United States); Herring, C M; Bulson, J M [Eden Park Illumination, 903 North Country Fair Drive, Champaign, IL 61821 (United States)

    2011-06-08

    Flat, thin and lightweight lamps providing spatially uniform and dimmable illumination from active areas as large as 400 cm{sup 2} are being developed for general illumination and specialty applications. Comprising an array of low-temperature, nonequilibrium microplasmas driven by a dielectric barrier structure and operating at pressures of typically 400-700 Torr, these lamps have a packaged thickness <4 mm and yet produce luminance values beyond 26 000 cd m{sup -2} with a luminous efficacy approaching 30 lm W{sup -1}. Third generation lamps, presently in limited production, offer a correlated colour temperature in the 3000-4100 K interval and a colour rendering index of 80. Current lamps employ Xe{sub 2} ({lambda} {approx} 172 nm) as the primary emitter photoexciting a mixture of phosphors, and the pressure dependence of the wavelength-integrated fluorescence from the electronically excited dimer has been investigated with a vacuum ultraviolet spectrometer. In contrast to other promising lighting technologies, the decline in luminous efficacy of microplasma lamps with increasing power delivered to the lamp is small. For a 6 x 6 inch{sup 2} ({approx}225 cm{sup 2}) lamp, efficacy falls <16% when the radiant output (luminance) is raised from 2000 cd m{sup -2} to > 10 000 cd m{sup -2}.

  1. Loop-mediated isothermal amplification (LAMP) assay for the identification of Echinococcus multilocularis infections in canine definitive hosts.

    Science.gov (United States)

    Ni, Xingwei; McManus, Donald P; Yan, Hongbin; Yang, Jifei; Lou, Zhongzi; Li, Hongmin; Li, Li; Lei, Mengtong; Cai, Jinzhong; Fan, Yanlei; Li, Chunhua; Liu, Quanyuan; Shi, Wangui; Liu, Xu; Zheng, Yadong; Fu, Baoquan; Yang, Yurong; Jia, Wanzhong

    2014-05-30

    Alveolar echinococcosis, caused by the metacestode larval stage of Echinococcus multilocularis, is a zoonosis of public health significance and is highly prevalent in northwest China. To effectively monitor its transmission, we developed a new rapid and cheap diagnostic assay, based on loop-mediated isothermal amplification (LAMP), to identify canine definitive hosts infected with E. multilocularis. The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. multilocularis and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR assay, using DNA extracted from the feces of dogs experimentally infected with E. multilocularis, on 189 dog fecal samples collected from three E. multilocularis-endemic regions in Qinghai province, the People's Republic of China, and 30 negative control copro-samples from dogs from an area in Gansu province that had been subjected to an intensive de-worming program. Light microscopy was also used to examine the experimentally obtained and field collected dog copro-samples for the presence of E. multilocularis eggs. The E. multilocularis-positivity rates obtained for the field-collected fecal samples were 16.4% and 5.3% by the LAMP and PCR assays, respectively, and all samples obtained from the control dogs were negative. The LAMP assay was able to detect E. multilocularis DNA in the feces of experimentally infected dogs at 12 days post-infection, whereas the PCR assay was positive on the 17th day and eggs were first detectable by light microscopy at day 44 post-challenge. The earlier specific detection of an E. multilocularis infection in dog copro-samples indicates that the LAMP assay we developed is a realistic alternative method for the field surveillance of canines in echinococcosis-endemic areas.

  2. Decolorization of brilliant green dye using immersed lamp sonophotocatalytic reactor

    Science.gov (United States)

    Gole, Vitthal L.; Priya, Astha; Danao, Sanjay P.

    2017-12-01

    The textile and dye industries require an enormous amount of water for processing and produce a large volume of wastewater. Generated wastewater had potential hazards and a threat to the aquatic biota. The present work investigates the decolorization of brilliant green dye using a combination of two advanced oxidation techniques viz sonocatalysis and photocatalysis (immersed lamp) known as sonophotocatalysis (3 L capacity). The efficiency of decolorization is further improved in the presence of various additives viz. copper oxide, zinc oxide, and sodium chloride. The maximum decolorization of brilliant green (BG) (94.8% in 120 min) obtained in the presence of zinc oxide. The total organic carbon of the treated samples was measured to monitor complete mineralization of BG. The sonophotocatalytic process (in the presence of zinc oxide) shows maximum mineralization. Synergic combination of two oxidation processes increased the production of oxidizing radicals. Continuous cleaning of catalyst surface (due to sonolysis effect) improves the activity of the catalyst for photolysis operation. The present work is highly useful for the development of a sonophotocatalytic process.

  3. An ion quencher operated lamp for multiplexed fluorescent bioassays.

    Science.gov (United States)

    Qing, Taiping; Sun, Huanhuan; He, Xiaoxiao; Huang, Xiaoqin; He, Dinggeng; Bu, Hongchang; Qiao, Zhenzhen; Wang, Kemin

    2018-02-01

    A novel and adjustable lamp based on competitive interaction among dsDNA-SYBR Green I (SGI), ion quencher, and analyte was designed for bioanalysis. The "filament" and switch of the lamp could be customized by employing different dsDNA and ion quencher. The poly(AT/TA) dsDNA was successfully screened as the most effective filament of the lamp. Two common ions, Hg 2+ and Fe 3+ , were selected as the model switch, and the corresponding ligand molecules cysteine (Cys) and pyrophosphate ions (PPi) were selected as the targets. When the fluorescence-quenched dsDNA/SGI-ion complex was introduced into a target-containing system, ions could be bound by competitive molecules and separate from the complex, thereby lighting the lamp. However, no light was observed if the biomolecule could not snatch the metal ions from the complex. Under the optimal conditions, sensitive and selective detection of Cys and PPi was achieved by the lamp, with practical applications in fetal bovine serum and human urine. This ion quencher regulated lamp for fluorescent bioassays is simple in design, fast in operation, and is more convenient than other methods. Significantly, as many molecules could form stable complexes with metal ions selectively, this ion quencher operated lamp has potential for the detection of a wide spectrum of analytes. Graphical abstract A novel and adjustable lamp on the basis of competitive interaction among dsDNA-SYBR Green I, ions quencher and analyte was designed for bioanalysis. The filament and switch of lamp could be customized by employing different dsDNA and ions quencher.

  4. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests

    NARCIS (Netherlands)

    Emmerzaal, A.; Wit, de J.J.; Dijkstra, T.; Bakker, D.; Ziiderveld, van F.G.

    2002-01-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the

  5. Radiation exposure and doses resulting from natural radioactivity in the environment and radioactive isotopes in food chains. Part of a coordinated programme on environmental monitoring for radiological protection in Asia and the Far East

    International Nuclear Information System (INIS)

    Rab Molla, M.A.

    1978-11-01

    A coordinated research programme on environmental radioactivity monitoring in Asia and Far East was undertaken. The following studies were carried out: Determination of fallout 137 Cs, 90 Sr and natural radionuclides of 208 Tl and of levels of K and Ca in vegetables and soils; study of the influence of K in the uptake of 137 Cs by vegetable crops from soil in contral fields and pot experiments; survey of background radiation levels in Bangladesh including the monazite-bearing areas of Cox's Bazar

  6. Field Evaluation of Programmable Thermostats

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, O. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Tiefenbeck, V. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Duvier, C. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Qin, A. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Cheney, K. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Akers, C. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States); Roth, K. [Fraunhofer Center for Sustainable Energy Systems (CSE), Cambridge, MA (United States)

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. The Fraunhofer team hypothesized that home occupants with high-usability thermostats would be more likely to use them to save energy than people with a basic thermostats. In this report, the team discusses results of a project in which the team monitored and compared programmable thermostats with basic thermostats in an affordable housing apartment complex.

  7. 78 FR 51463 - Energy Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures

    Science.gov (United States)

    2013-08-20

    ... merging the metal halide lamp fixture and the high-intensity discharge (HID) lamp rulemakings. This NOPR... Conservation Program: Energy Conservation Standards for Metal Halide Lamp Fixtures; Proposed Rule #0;#0;Federal...: Energy Conservation Standards for Metal Halide Lamp Fixtures AGENCY: Office of Energy Efficiency and...

  8. In-situ measurements of material thermal parameters for accurate LED lamp thermal modelling

    NARCIS (Netherlands)

    Vellvehi, M.; Perpina, X.; Jorda, X.; Werkhoven, R.J.; Kunen, J.M.G.; Jakovenko, J.; Bancken, P.; Bolt, P.J.

    2013-01-01

    This work deals with the extraction of key thermal parameters for accurate thermal modelling of LED lamps: air exchange coefficient around the lamp, emissivity and thermal conductivity of all lamp parts. As a case study, an 8W retrofit lamp is presented. To assess simulation results, temperature is

  9. Breast and cervical cancer screening programme implementation in 16 countries

    DEFF Research Database (Denmark)

    Dowling, Emily C; Klabunde, Carrie; Patnick, Julietta

    2010-01-01

    There is a continuing need to monitor and evaluate the impact of organized screening programmes on cancer incidence and mortality. We report results from a programme assessment conducted within the International Cancer Screening Network (ICSN) to understand the characteristics of cervical screening...... programmes within countries that have established population-based breast cancer screening programmes....

  10. Investigation of acoustic resonances in high-power lamps

    International Nuclear Information System (INIS)

    Kettlitz, M; Zalach, J; Rarbach, J

    2011-01-01

    High-power, medium-pressure, mercury-containing lamps are used as UV sources for many industrial applications. Lamps investigated in this paper are driven with an electronic ballast with a non-sinusoidal current waveform at a fixed frequency of 20 kHz and a maximum power output of 35 kW. Instabilities can occur if the input power is reduced below 50%. The reason is identified as acoustic resonances in the lamp. Comparison of calculated and measured resonance frequencies shows a good agreement and explains the observed lamp behaviour. This has led to the development of a new ballast prototype which is able to avoid instabilities by changing the driving frequency dependent on the applied power.

  11. Anti-glare LED lamps with adjustable illumination light field.

    Science.gov (United States)

    Chen, Yung-Sheng; Lin, Chung-Yi; Yeh, Chun-Ming; Kuo, Chie-Tong; Hsu, Chih-Wei; Wang, Hsiang-Chen

    2014-03-10

    We introduce a type of LED light-gauge steel frame lamp with an adjustable illumination light field that does not require a diffusion plate. Base on the Monte Carlo ray tracing method, this lamp has a good glare rating (GR) of 17.5 at 3050 lm. Compared with the traditional LED light-gauge steel frame lamp (without diffusion plate), the new type has low GR. The adjustability of the illumination light field could improve the zebra effect caused by the inadequate illumination light field of the lamp. Meanwhile, we adopt the retinal image analysis to discuss the influence of GR on vision. High GR could reflect stray light on the retinal image, which will reduce vision clarity and hasten the feeling of eye fatigue.

  12. LOOP mediated isothermal AMPlification (LAMP) in diagnosis of ...

    African Journals Online (AJOL)

    2012-02-28

    Feb 28, 2012 ... Due to disadvantages of known ... advantages, as compared to traditional diagnostic methods like ... Products of LAMP reaction are DNA fragments with stemloop ..... "Differentiation of Cryptococcus neoformans varieties and.

  13. Evaluation and improvement of LAMP assays for detection of ...

    African Journals Online (AJOL)

    ... principle of the reaction per- formed by a DNA polymerase with strand displacement ... target sequence in the later stage of the LAMP reaction. Under an isothermal ..... Mutation detec- tion and single-molecule counting using isothermal roll-.

  14. Metal-halide lamp design: atomic and molecular data needed

    International Nuclear Information System (INIS)

    Lapatovich, Walter P

    2009-01-01

    Metal-halide lamps are a subset of high intensity discharge (HID) lamps so named because of their high radiance. These lamps are low temperature (∼0.5 eV), weakly ionized plasmas sustained in refractory but light transmissive envelopes by the passage of electric current through atomic and molecular vapors. For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-780 nm) to permit the light so generated to render colors comparable to natural sunlight. This is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency (efficacy) and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The electrons, atoms and radicals are in local thermodynamic equilibrium (LTE), but not with the radiation field. Strong thermal (10 6 K m -1 ) and density gradients are sustained in the discharge. Atomic radiation produced in the high-temperature core transits through colder gas regions where it interacts with cold atoms and un-dissociated molecules before exiting the lamp. Power balance and spectral output of the lamp are directly affected by the strength of atomic transitions. Attempts to simulate the radiative output of functional metal-halide lamps have been successful only in very simple cases. More data (e.g. the atomic transition probabilities of Ce i) are necessary to improve lamp performance, to select appropriate radiators and in scaling the lamp geometry to various wattages for specific applications.

  15. Determination of line broadening constants in high pressure discharge lamps

    International Nuclear Information System (INIS)

    Weiss, M; Schubert, H; Meier, S; Born, M; Reiter, D; Stroesser, M

    2005-01-01

    A numerical model of the radiative transfer in high pressure metal halide discharge lamps is used to determine line broadening parameters for atomic scandium lines. The determined broadening constants are in qualitative agreement with theoretical estimates in many cases, but significant deviations exist. The data obtained from this paper can, therefore, be used to further improve modelling of radiative contributions to the energy balance in such types of discharge lamps

  16. A gas discharge lamp for the extreme ultraviolet.

    Science.gov (United States)

    Nicholson, A J

    1970-05-01

    A gas discharge lamp is described suitable for producing the many-lined spectrum of hydrogen (85-160 nm) and the Hopfield continuum in helium (60-100 nm). It was designed for use with a window-less monochromator to study photoionization and operates at pressures below 50 Torr. The hydrogen lamp has a mode of operation which concentrates the discharge into the monochromator entrance slit.

  17. Slit-lamp photography and videography with high magnifications

    Science.gov (United States)

    Yuan, Jin; Jiang, Hong; Mao, Xinjie; Ke, Bilian; Yan, Wentao; Liu, Che; Cintrón-Colón, Hector R; Perez, Victor L; Wang, Jianhua

    2015-01-01

    Purpose To demonstrate the use of the slit-lamp photography and videography with extremely high magnifications for visualizing structures of the anterior segment of the eye. Methods A Canon 60D digital camera with Movie Crop Function was adapted into a Nikon FS-2 slit-lamp to capture still images and video clips of the structures of the anterior segment of the eye. Images obtained using the slit-lamp were tested for spatial resolution. The cornea of human eyes was imaged with the slit-lamp and the structures were compared with the pictures captured using the ultra-high resolution optical coherence tomography (UHR-OCT). The central thickness of the corneal epithelium and total cornea was obtained using the slit-lamp and the results were compared with the thickness obtained using UHR-OCT. Results High-quality ocular images and higher spatial resolutions were obtained by using the slit-lamp with extremely high magnifications and Movie Crop Function, rather than the traditional slit-lamp. The structures and characteristics of the cornea, such as the normal epithelium, abnormal epithelium of corneal intraepithelial neoplasia, LASIK interface, and contact lenses, were clearly visualized using this device. These features were confirmed by comparing the obtained images with those acquired using UHR-OCT. Moreover, the tear film debris on the ocular surface and the corneal nerve in the anterior corneal stroma were also visualized. The thicknesses of the corneal epithelium and total cornea were similar to that measured using UHR-OCT (P photography and videography with extremely high magnifications allows better visualization of the anterior segment structures of the eye, especially of the epithelium, when compared with the traditional slit-lamp. PMID:26020484

  18. Critical pathway studies for selected radionuclides. Part of a coordinated programme on environmental monitoring for radiological protection in Asia and the Far East

    International Nuclear Information System (INIS)

    Bhat, I.S.

    1980-04-01

    The programme carried out critical pathway studies for selected radionuclides ( 60 Co, 63 Ni, 59 Fe, 54 Mn, sup(110m)Ag, 106 Ru and 144 Ce) and assessed population exposure in the vicinity of Tarapur Atomic Power Station. The following topics are covered under the programme. (i) Demographic study of dietary habits and consumption data for Tarapur population. (ii) Concentration and accumulation of radionuclides in food products. (iii) Determination of radionuclides in sea water, silt, marine algae and marine organisms at Tarapur Atomic Power Station (TAPS) Site. (iv) Behaviour of radionuclides released to marine environment. (v) Evaluation of critical exposure pathway. (vi) Population exposure in the vicinity of Tarapur Atomic Power Station

  19. Deuterium lamps as transfer standards for spectral radiance measurements

    International Nuclear Information System (INIS)

    Key, P.J.; Nettleton, D.H.

    1985-01-01

    This report describes the work carried out at NPL and PTB to improve the performance of a low pressure deuterium discharge lamp, so that it can be used as a transfer standard in the spectral range 120 to 350 nm. To this end it was necessary: - to replace the original quartz windows by magnesium fluoride single crystal plates, which were cut perpendicular to the c-axis of the crystal and which had to be free of impurities, - to construct the lamps in that way that the directional uniformity of the emitted radiation is within the demands, - to age the lamps and to preselect only those of which the irradiance was stable within ± 1% during a thirty minute period after warm-up, - to improve the commercially available electrical power supply to meet the operational needs of the lamps. Thus, the deuterium lamps drifted by about 3% over a period of 100 h at all wavelengths except at 250 nm, where the ageing increased to 4.5%. A liquid nitrogen trap has been developed which can be installed between the vacuum system and the lamp. This reduced to about 2% the decrease of the window's transmission during the first hour of operation, caused by the deposition of oil from the vacuum system

  20. The instantaneous light-intensity function of a fluorescent lamp

    Energy Technology Data Exchange (ETDEWEB)

    Gluskin, Emanuel [Holon Institute of Technology, 52 Golomb St., Holon 58102 (Israel): Electrical Engineering Department, Ben-Gurion University, Beer-Sheva 84105 (Israel)]. E-mail: gluskin@ee.bgu.ac.il; Topalis, Frangiskos V. [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece); Kateri, Ifigenia [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece); Bisketzis, Nikolas [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece)

    2006-05-08

    Using some simple physics and 'system' considerations, the instantaneous light intensity function {psi}(t) of a fluorescent lamp fed via a regular ballast from the 50-60 Hz line is argued to be {psi}(t)={psi}{sub min}+bp(t), where p(t) is the instantaneous power function of the lamp, and b is a constant, and experiment confirms this formula well. The main frequency of {psi}(t), the very significant singularity of its waveform, and the relative intensity of the ripple, i.e., the depth of the modulation, are the focus. The results are important for research into the vision problem that some humans (autistic, but others, too) experience regarding fluorescent light. The inertia of the processes in the lamp which are responsible for the light emission, provides some nonzero emission at the instants when p(t) has zeros. The smaller the volume of the tube and the mass of the gas are, the more weakly the inertia of the processes is expressed, and the relatively smaller is {psi}{sub min}. However, it should be very difficult to theoretically obtain {psi}(t), in particular {psi}{sub min}, from the very complicated physics of the low-pressure discharge in the tube. We conclude that {psi}{sub min} has to be connected with the (also easily measured) lamp's inductance. The work should attract more attention of the physicists to the properties of the common fluorescent lamps. escent lamps.

  1. Case Study on Justification: High Intensity Discharge Lamps. Annex II

    International Nuclear Information System (INIS)

    2016-01-01

    High intensity discharge lamps produce bright white light of a high intensity in an energy efficient manner. These lamps are typically used in large numbers in public and professional settings such as shops, warehouses, hotels and offices. They are also used in outdoor applications to illuminate streets, buildings, statues, flags and gardens and further as architectural lighting. They also have applications associated with film projection in cinemas, manufacture of semiconductors, fluorescence endoscopy and microscopy, schlieren photography, hologram projection, ultraviolet curing, sky beamers and car headlights. Some types of high intensity discharge lamp, as well as certain other consumer products for lighting, contain radioactive substances for functional reasons. The radionuclides that are typically incorporated into high intensity discharge lamps are 85 Kr and 232 Th. Given the wide range of uses, specific decisions on justification may be required for different applications. A small number of safety assessments for high intensity discharge lamps have been carried out and published. No published decisions at the national level specifically addressing the justification of the use of high intensity discharge lamps have been identified

  2. Development and commercialisation of rechargeable wooden LED lamps

    Directory of Open Access Journals (Sweden)

    Bradley Schultz

    2013-02-01

    Full Text Available The focus of this project was to work with local staff at Kathmandu Alternative Power and Energy Group to commercialise a product which would generate recurring income for the organisation, to enable staff to learn the process of commercialisation and to provide employment and skills in the local community. Rechargeable Light Emitting Diode (LED lamps were deemed suitable for these aims, as they are a simple product, yet one that is urgently required in Nepal due to the prevalence of ‘load-shedding’ – scheduled electrical blackouts. After reviewing the market, it was found that it would be impossible to compete with the price of cheap imported Chinese rechargeable LED lamps, so an alternative approach was taken. This involved sourcing wooden off-cuts from a local furniture factory and transforming them into attractive desk lamps, with the target market being affluent Nepalis, ex-pats living in Nepal and tourists. Successful initial sales were achieved through a Kathmandu-based ex-pat email group, hotel-markets and souvenir stores. KAPEG staff have continued the project, producing variations on the initial design including Himalayan rock salt lamps, employing local people to manufacture lamps and selling them at markets in Kathmandu. Staffing and marketing challenges remain to ensure the lamp manufacture and sales continue.

  3. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    Science.gov (United States)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-11-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×108 cm-2 s-1 to 1014 cm-2 s-1. The 202Hg(n,γ)203Hg nuclear reaction was used for mercury mass evaluation. Activities of 203Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg2Cl2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps.

  4. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  5. The sero-monitoring of rinderpest throughout Africa. Phase two. Results for 1993. Proceedings of a research co-ordination meeting of the FAO/IAEA/SIDA/OAU/IBAR/PARC co-ordinated research programme

    International Nuclear Information System (INIS)

    1994-11-01

    1993 has been a significant year for PARC with the initiation of the Global Rinderpest Eradication Programme (GREP) providing a new emphasis in the drive towards the final elimination of rinderpest and its causative virus. For PARC this has culminated in a declaration by Egypt that it will cease vaccination at the beginning of 1994 and a strong commitment by a number of West African countries that they too will cease vaccination during 1994 and make the OIE Declarations of Provisional Freedom from Rinderpest. These significant steps forward in the eradication process would not have been possible without the information and confidence provided by the PARC sero-monitoring network. But even more important has been the clear demonstration that is possible to maintain the routine operation of an epidemiological network providing reliable results for a number of years in over 20 African countries. Such a system is vital if rinderpest is to be eradicated from the region and the bold move of a number of countries to now cease vaccinating is, in part, a testimony to the success of this network. This publication details the 1993 sero-monitoring results on a country to country basis, provides details of the external quality assurance programme and provides a series of conclusions and recommendations on the way to proceed in the future for this surveillance network. Refs, figs and tabs

  6. Technology Programme

    Energy Technology Data Exchange (ETDEWEB)

    Batistoni, Paola; De Marco, Francesco; Pieroni, Leonardo [ed.

    2005-07-01

    The technology activities carried out by the Euratom-ENEA Association in the framework of the European Fusion Development Agreement concern the Next Step (International Thermonuclear Experimental Reactor - ITER), the Long-Term Programme (breeder blanket, materials, International Fusion Materials Irradiation Facility - IFMIF), Power Plant Conceptual Studies and Socio-Economic Studies. The Underlying Technology Programme was set up to complement the fusion activities as well to develop technologies with a wider range of interest. The Technology Programme mainly involves staff from the Frascati laboratories of the Fusion Technical and Scientific Unit and from the Brasimone laboratories of the Advanced Physics Technologies Unit. Other ENEA units also provide valuable contributions to the programme. ENEA is heavily engaged in component development/testing and in design and safety activities for the European Fusion Technology Programme. Although the work documented in the following covers a large range of topics that differ considerably because they concern the development of extremely complex systems, the high level of integration and coordination ensures the capability to cover the fusion system as a whole. In 2004 the most significant testing activities concerned the ITER primary beryllium-coated first wall. In the field of high-heat-flux components, an important achievement was the qualification of the process for depositing a copper liner on carbon fibre composite (CFC) hollow tiles. This new process, pre-brazed casting (PBC), allows the hot radial pressing (HRP) joining procedure to be used also for CFC-based armour monoblock divertor components. The PBC and HRP processes are candidates for the construction of the ITER divertor. In the materials field an important milestone was the commissioning of a new facility for chemical vapour infiltration/deposition, used for optimising silicon carbide composite (SiCf/SiC) components. Eight patents were deposited during 2004

  7. Technology Programme

    International Nuclear Information System (INIS)

    Batistoni, Paola; De Marco, Francesco; Pieroni, Leonardo

    2005-01-01

    The technology activities carried out by the Euratom-ENEA Association in the framework of the European Fusion Development Agreement concern the Next Step (International Thermonuclear Experimental Reactor - ITER), the Long-Term Programme (breeder blanket, materials, International Fusion Materials Irradiation Facility - IFMIF), Power Plant Conceptual Studies and Socio-Economic Studies. The Underlying Technology Programme was set up to complement the fusion activities as well to develop technologies with a wider range of interest. The Technology Programme mainly involves staff from the Frascati laboratories of the Fusion Technical and Scientific Unit and from the Brasimone laboratories of the Advanced Physics Technologies Unit. Other ENEA units also provide valuable contributions to the programme. ENEA is heavily engaged in component development/testing and in design and safety activities for the European Fusion Technology Programme. Although the work documented in the following covers a large range of topics that differ considerably because they concern the development of extremely complex systems, the high level of integration and coordination ensures the capability to cover the fusion system as a whole. In 2004 the most significant testing activities concerned the ITER primary beryllium-coated first wall. In the field of high-heat-flux components, an important achievement was the qualification of the process for depositing a copper liner on carbon fibre composite (CFC) hollow tiles. This new process, pre-brazed casting (PBC), allows the hot radial pressing (HRP) joining procedure to be used also for CFC-based armour monoblock divertor components. The PBC and HRP processes are candidates for the construction of the ITER divertor. In the materials field an important milestone was the commissioning of a new facility for chemical vapour infiltration/deposition, used for optimising silicon carbide composite (SiCf/SiC) components. Eight patents were deposited during 2004

  8. Lysosome-Associated Membrane Proteins (LAMP Maintain Pancreatic Acinar Cell Homeostasis: LAMP-2–Deficient Mice Develop PancreatitisSummary

    Directory of Open Access Journals (Sweden)

    Olga A. Mareninova

    2015-11-01

    Full Text Available Background & Aims: The pathogenic mechanism of pancreatitis is poorly understood. Recent evidence implicates defective autophagy in pancreatitis responses; however, the pathways mediating impaired autophagy in pancreas remain largely unknown. Here, we investigate the role of lysosome associated membrane proteins (LAMPs in pancreatitis. Methods: We analyzed changes in LAMPs in experimental models and human pancreatitis, and the underlying mechanisms: LAMP deglycosylation and degradation. LAMP cleavage by cathepsin B (CatB was analyzed by mass spectrometry. We used mice deficient in LAMP-2 to assess its role in pancreatitis. Results: Pancreatic levels of LAMP-1 and LAMP-2 greatly decrease across various pancreatitis models and in human disease. Pancreatitis does not trigger the LAMPs’ bulk deglycosylation but induces their degradation via CatB-mediated cleavage of the LAMP molecule close to the boundary between luminal and transmembrane domains. LAMP-2 null mice spontaneously develop pancreatitis that begins with acinar cell vacuolization due to impaired autophagic flux, and progresses to severe pancreas damage characterized by trypsinogen activation, macrophage-driven inflammation, and acinar cell death. LAMP-2 deficiency causes a decrease in pancreatic digestive enzymes content, and stimulates the basal and inhibits cholecystokinin-induced amylase secretion by acinar cells. The effects of LAMP-2 knockout and acute cerulein pancreatitis overlap, which corroborates the pathogenic role of LAMP decrease in experimental pancreatitis models. Conclusions: The results indicate a critical role for LAMPs, particularly LAMP-2, in maintaining pancreatic acinar cell homeostasis and provide evidence that defective lysosomal function, resulting in impaired autophagy, leads to pancreatitis. Mice with LAMP-2 deficiency present a novel genetic model of human pancreatitis caused by lysosomal/autophagic dysfunction. Keywords: Amylase Secretion, Autophagy

  9. Comparison of direct and alternating current vacuum ultraviolet lamps in atmospheric pressure photoionization.

    Science.gov (United States)

    Vaikkinen, Anu; Haapala, Markus; Kersten, Hendrik; Benter, Thorsten; Kostiainen, Risto; Kauppila, Tiina J

    2012-02-07

    A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production. © 2012 American Chemical Society

  10. Implementation of the Preventive Radiation Protection Act; here: Regulation governing ambient radioactivity monitoring subject to the Preventive Radiation Protection Act. Pt. 1. Measuring programme for specified normal operation monitoring (routine measuring programme). BMU circular letter dated 28.07.94 -RS II 6 - 15 603/3

    International Nuclear Information System (INIS)

    1994-01-01

    The regulation addresses the competent Federal and Land authorities responsible for implementation of the Preventive Radiation Protection Act, and the competent highest Land authorities. The regulation defines the scope of obligatory measurement of ambient radioactivity during normal operation of installations and determines the measuring techniques to be applied for this purpose. The programme determines compulsory instructions to be observed in the performance of the routine measuring programme by the competent Federal and Land authorities and thus ensures nationwide application of standard procedures

  11. Physics of mercury-free high-pressure discharge lamps

    International Nuclear Information System (INIS)

    Born, M

    2002-01-01

    This paper gives a summary of recent results about the replacement of mercury in high-pressure discharge lamps by metallic zinc. Actually, this topic is of high relevance for the lighting industry due to the need of more environmentally friendly products. The work presented here is supported by the German government under contract no 13N8072 and 13N8264. Due to upcoming European legislations which are expected for the year 2003, the replacement of mercury in lighting products is a high priority task. For example, mercury-free headlight discharge lamps are requested by the automotive industry. Pure zinc/argon discharges as well as lamps including zinc or mercury and metal halide additives are investigated. Experimental data are compared with model calculations of the energy balance involving the transport of heat and radiation. Since the excitation energies of relevant zinc transitions are lower than for mercury, axis temperatures of pure zinc lamps are about 300 K below the value of mercury arcs. In addition, the thermal conductivity of zinc including the contribution of radiation diffusion is larger than compared to mercury. From lamp voltage measurements it is found that the cross section for elastical electron scattering by zinc atoms is about the same than for mercury. When adding metal halides to a pure zinc discharge with argon as a starting gas, i.e. NaI, TlI, DyI 3 , axis temperatures decrease to about 5100 K due to strong radiation cooling. In order to obtain sufficiently large lamp voltages, wall temperatures of more than 1300 K are adjusted by means of polycrystalline aluminaoxide (Al 2 O 3 ) as a wall material. Electric field strengths of 6.0 and 8.6 V mm -1 are measured for metal halide lamps containing zinc or mercury, respectively. The light technical data of the discharges are very close, since mercury and zinc do not contribute significantly to the radiation in the visible range. Efficacies of up to 93 and 100 lm W -1 are found in metal halide

  12. Selective gettering of hydrogen in high pressure metal iodide lamps

    International Nuclear Information System (INIS)

    Kuus, G.

    1976-01-01

    One of the main problems in the manufacture of high pressure gas discharge lamps is the elimination of gaseous impurities from their arc tubes. Long degassing processes of all the lamp components are necessary in order to produce lamps with a low ignition voltage and good maintenance of the radiation properties. The investigation described deals with a selective getter place in the arc tube which can replace the long degassing process. The getter consists of a piece of yttrium encapsulated in thin tantalum foil. By this way it is possible to use the gettering action of tantalum and yttrium without having reaction between the metal iodide of the arc tube and yttrium. Yttrium is used because this metal can adsorb a large quantity of hydrogen even at a temperature of 1000 0 C. Hydrogen forms the main gaseous impurity in the high pressure metal iodide lamp. For this reason the adsorption properties like adsorption rate and capacity of the tantalum--yttrium getter for hydrogen are examined, and the results obtained from lamp experiments are given

  13. High-frequency cold ignition of fluorescent lamps

    International Nuclear Information System (INIS)

    Haverlag, M.; Sormani, J.; Heuvelmans, J.; Geven, A.; Kaldenhoven, L.; Heijne, G.; Kraus, A.

    2002-01-01

    Experimental and theoretical investigations have been performed on the ignition process of low-pressure mercury-noble gas fluorescent lamps operating on a 50 kHz electronic driver circuit. In case the electrodes of the lamp are not heated prior to the ignition process, the ignition process can, under certain conditions, lead to premature fracture of the coiled-coil electrode, which means that the lamp ceases to operate before the emitter is consumed completely. Experimental studies of this process have shown that the erosion process responsible for this premature end-of-life consists of localized sputtering of the tungsten electrode by energetic ions from the glow discharge that is present during the ignition process. In order to understand the basic process that leads to localized sputtering of the electrodes in a glow discharge, a simple glow-discharge fluid model, in combination with a finite-element model of the heat transport in the electrode, has been built. The model shows that thermionic emission can supply a significant fraction of the electrons already at temperatures far below the normal operating temperature in fluorescent lamps. This thermionic emission is responsible for a contraction process. After the beginning of the discharge contraction it takes typically a few milliseconds before the glow-to-arc transition is observed in the lamp voltage and the normal electrode operating temperature is reached. During this time localized sputtering takes place, which eventually leads to coil fracture. (author)

  14. Monitoring natural phytoplankton communities

    DEFF Research Database (Denmark)

    Haraguchi, L.; Jakobsen, H. H.; Lundholm, Nina

    2017-01-01

    The phytoplankton community can vary within hours (physiology) to years (climatic and anthropogenic responses), and monitoring at different timescales is relevant for understanding community functioning and assessing changes. However, standard techniques used in monitoring programmes are time...

  15. Tracking the career development of scientists in low- and middle-income countries trained through TDR's research capacity strengthening programmes: Learning from monitoring and impact evaluation.

    Science.gov (United States)

    Halpaap, Béatrice; Vahedi, Mahnaz; Certain, Edith; Alvarado, Tini; Saint Martin, Caroline; Merle, Corinne; Mihut, Michael; Launois, Pascal

    2017-12-01

    The Special Programme for Research and Training in Tropical Diseases (TDR) co-sponsored by UNICEF, UNDP, World Bank and WHO has been supporting research capacity strengthening in low- and middle-income countries for over 40 years. In order to assess and continuously optimize its capacity strengthening approaches, an evaluation of the influence of TDR training grants on research career development was undertaken. The assessment was part of a larger evaluation conducted by the European Science Foundation. A comprehensive survey questionnaire was developed and sent to a group of 117 trainees supported by TDR who had completed their degree (masters or PhD) between 2000 and 2012; of these, seventy seven (77) responded. Most of the respondents (80%) rated TDR support as a very important factor that influenced their professional career achievements. The "brain drain" phenomenon towards high-income countries was particularly low amongst TDR grantees: the rate of return to their region of origin upon completion of their degree was 96%. A vast majority of respondents are still working in research (89%), with 81% of respondents having participated in multidisciplinary research activities; women engaged in multidisciplinary collaboration to a higher extent than men. However, only a minority of all have engaged in intersectoral collaboration, an aspect that would require further study. The post-degree career choices made by the respondents were strongly influenced by academic considerations. At the time of the survey, 92% of all respondents hold full-time positions, mainly in the public sector. Almost 25% of the respondents reported that they had influenced policy and practice changes. Some of the challenges and opportunities faced by trainees at various stages of their research career have been identified. Modalities to overcome these will require further investigation. The survey evidenced how TDR's research capacity grant programmes made a difference on researchers' career

  16. Tracking the career development of scientists in low- and middle-income countries trained through TDR's research capacity strengthening programmes: Learning from monitoring and impact evaluation.

    Directory of Open Access Journals (Sweden)

    Béatrice Halpaap

    2017-12-01

    Full Text Available The Special Programme for Research and Training in Tropical Diseases (TDR co-sponsored by UNICEF, UNDP, World Bank and WHO has been supporting research capacity strengthening in low- and middle-income countries for over 40 years. In order to assess and continuously optimize its capacity strengthening approaches, an evaluation of the influence of TDR training grants on research career development was undertaken. The assessment was part of a larger evaluation conducted by the European Science Foundation. A comprehensive survey questionnaire was developed and sent to a group of 117 trainees supported by TDR who had completed their degree (masters or PhD between 2000 and 2012; of these, seventy seven (77 responded. Most of the respondents (80% rated TDR support as a very important factor that influenced their professional career achievements. The "brain drain" phenomenon towards high-income countries was particularly low amongst TDR grantees: the rate of return to their region of origin upon completion of their degree was 96%. A vast majority of respondents are still working in research (89%, with 81% of respondents having participated in multidisciplinary research activities; women engaged in multidisciplinary collaboration to a higher extent than men. However, only a minority of all have engaged in intersectoral collaboration, an aspect that would require further study. The post-degree career choices made by the respondents were strongly influenced by academic considerations. At the time of the survey, 92% of all respondents hold full-time positions, mainly in the public sector. Almost 25% of the respondents reported that they had influenced policy and practice changes. Some of the challenges and opportunities faced by trainees at various stages of their research career have been identified. Modalities to overcome these will require further investigation. The survey evidenced how TDR's research capacity grant programmes made a difference on

  17. The Effects of Lamp Spectral Distribution on Sky Glow over Observatories

    Science.gov (United States)

    2015-01-01

    overhead sky glow as a function of distance up to 300 km, from a variety of lamp types, including common gas discharge lamps and several types of LED...distance up to 300 km, from a variety of lamp types, in- cluding common gas discharge lamps and several types of LED lamps . We conclude for both...MAR 2015 2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE The Effects of Lamp Spectral Distribution on Sky Glow

  18. Detection of early and single infections of Schistosoma japonicum in the intermediate host snail, Oncomelania hupensis, by PCR and loop-mediated isothermal amplification (LAMP) assay.

    Science.gov (United States)

    Kumagai, Takashi; Furushima-Shimogawara, Rieko; Ohmae, Hiroshi; Wang, Tian-Ping; Lu, Shaohong; Chen, Rui; Wen, Liyong; Ohta, Nobuo

    2010-09-01

    Polymerase chain reaction (PCR) with the specific primer set amplifying 28S ribosomal DNA (rDNA) of Schistosoma japonicum was able to detect genomic DNA of S. japonicum, but not S. mansoni, at 100 fg. This procedure enabled us to detect the DNA from a single miracidium and a snail infected with one miracidium at just 1 day after infection. We compared these results with those from loop-mediated isothermal amplification (LAMP) targeting 28S rDNA and found similar results. The LAMP could amplify the specific DNA from a group of 100 normal snails mixed with one infected snail A PCR screening of infected snails from endemic regions in Anhui Province revealed schistosomal DNA even in snails found negative by microscopy. PCR and LAMP show promise for monitoring the early infection rate in snails, and they may be useful for predicting the risk of infection in the endemic places.

  19. ISOLDE PROGRAMME

    CERN Multimedia

    Fedosseev, V; Herfurth, F; Scheidenberger, C; Geppert, C; Gorges, C; Ratajczyk, T; Wiederhold, J C; Vogel, S; Munch, M K; Nieminen, P; Pakarinen, J J A; Lecesne, N; Bouzomita, H; Grinyer, J; Marques moreno, F M; Parlog, M; Blank, B A; Pedroza, J; Ghetta, V; Lozeva, R; Zacarias, S M; Guillemaud mueller, D S; Cottereau, E; Cheikh mhamed, M; Tusseau nenez, S; Tungate, G; Walker, P M; Smith, A G; Fitzpatrick, C; Dominik, W M; Karny, M; Ciemny, A A; Nyman, G H; Thies, R M A; Lindberg, S K G; Langouche, G F; Velten, P; Araujo escalona, V I; Boudreau, M; Domnanich, K A; Richter, D; Lutter, R J; Javaji, A; Engel, R Y; Wiehr, S; Nacher gonzalez, E; Jungclaus, A; Ribeiro jimenez, G; Marroquin alonso, I; Cal gonzalez, J; Paziy, V; Salsac, M; Murphy, C; Podolyak, Z F; Bajoga, A D; Butler, P; Pritchard, A; Colosimo, S J; Steer, A N; Fox, S P; Wadsworth, B A; Truesdale, V L; Al monthery, M; Bracco, A; Guttormsen, M S; Badea, M N; Calinescu, S; Ujeniuc, S; Cederkall, J A; Zemlyanoy, S; Donets, E D; Golovkov, M; Schweitzer, D K; Vranicar, A; Harrichunder, S; Ncube, M; Nannini, A; Strisovska, J; Wolf, E; Gerten, R F; Lehnert, J; Rainovski, G I; Pospisil, S; Datta pramanik, U; Benzoni, G; Fedorov, D; Maier, F M; Bonanni, A; Pfeiffer, B; Griesel, T; Wehner, L W; Mikkelsen, M; Recchia, F; Lenzi, S M; Smith, J F; Kelly, C M; Acosta sanchez, L A; Chavez lomeli, E R; De melo bandeira tavares, P M; Vieira, J M; Martins da silva, M A; Lima lopes, A M; Lopes leal, T J; Mader, J; Kessler, P; Laurent, B G; Schweikhard, L C; Marx, G H; Kulczycka, E; Komorowska, M; Da silva, M F; Goncalves marques, C P; Baptista peres, M A; Welander, J E; Reiter, P; Miller, C; Martin sanchez-cano, D; Wiens, A; Blazhev, A A; Braun, N; Cappellazzo, M V; Birkenbach, B; Gerst, R; Dannhoff, M F; Sithole, M J; Bilgier, B; Nardelli, S; Araujo mendes, C M; Agramunt ros, J; Valencia marin, E; Pantea, E; Hessberger, F P; Leduc, A J; Mitsuoka, S; Carbonari, A W; Buchegger, F J; Garzon camacho, A; Dapo, H; Papka, P; Stachura, M K; Stora, T; Marsh, B A; Thiboud, J A; Heylen, H; Antalic, S; Stahl, C; Bauer, C; Thurauf, M; Maass, B; Sturm, S; Boehm, C; Wolf, N R; Ways, M; Steinsberger, T P; Riisager, K; Ruotsalainen, P A; Bastin, B; Duval, F T; Penessot, G; Flechard, X D; Desrues, P; Giovinazzo, J; Kurtukian nieto, T; Ascher, P E L; Roccia, S; Matea, I; Croizet, H A G; Bonnin, C M; Morfouace, P; Smith, A J; Guin, R; Banerjee, D; Gunnlaugsson, H P; Ohtsubo, T; Zhukov, M V; Tengborn, E A; Welker, A; Giannopoulos, E; Dessagne, P; Juscamaita vivanco, Y; Da costa pereira, L M; Hustings, J; Yu, H; Kruecken, R; Nowak, A K; Jankowski, M; Cano ott, D; Galve lahoz, P; Murphy, A S J; Shand, C M; Jones, G D; Herzberg, R; Ikin, P; Revill, J P; Everett, C; Napoli, D R; Scarel, G; Larsen, A; Tornyi, T G; Pascu, S G; Stroe, L; Toma, S; Jansson, K; Dronjak fahlander, M; Krupko, S; Hurst, A M; Veskovic, M; Nikolov, J; Masenda, H; Sibanda, W N; Rocchini, M; Klimo, J; Deicher, M; Wichert, T; Kronenberg, J; Helmke, A; Meliani, Z; Ivanov, V S; Green, B L; Keatings, J M; Kuti, I; Halasz, Z; Henry, M O; Bras de sequeira amaral, V; Espirito santo, F; Da silva, D J; Rosendahl, S; Vianden, R J; Speidel, K; Agarwal, I; Faul, T; Kownacki, J M; Martins correia, J G; Lorenz, K; Costa miranda, S M; Granadeiro costa, A R; Zyabkin, D; Kotthaus, T; Pfeiffer, M; Gironi, L; Jensen, A; Romstedt, F; Constantino silva furtado, I; Heredia cardona, J A; Jordan martin, M D; Montaner piza, A; Zacate, M O; Plewinski, F; Mesli, A; Akakpo, E H; Pichard, A; Hergemoller, F; Neu, W; Fallis starhunter, J P; Voulot, D; Mrazek, J; Ugryumov, V; Savreux, R P; Kojouharov, I M; Kern, R O; Papst, O; Fitting, J; Lauer, M; Kirsebom, O S; Jensen, K L; Jokinen, A; Rahkila, P J; Hager, U D K; Konki, J P; Dubois, M; Orr, N A; Fabian, X; Huikari, J E; Goigoux, T; Magron, C; Zakari, A A; Maietta, M; Bachelet, C E M; Roussiere, B; Li, R; Canavan, R L; Lorfing, C; Foster, R M; Gislason, H P; Shayestehaminzadeh, S; Qi, B; Mukai, M; Watanabe, Y; Willmann, L; Kurcewicz, W; Wimmer, K; Meisel, Z P; Dorvaux, O; Nowacki, F; Koudriavtsev, I; Lievens, P; Delaure, B J P; Neyens, G; Ceruti, S; Bunka, M; Vermeulen, C; Umbricht, C A; De boer, J; Podadera aliseda, I; Alcorta moreno, M; Pesudo fortes, V; Zielinska, M; Korten, W; Wang, C H; Lotay, G J; Mason, P; Rice, S J; Regan, P H; Willenegger, L M; Andreev, A; Yavuzkanat, N; Hass, M; Kumar, V; Valiente dobon, J J; Crespo campo, L; Zamfir, N - V; Deleanu, D; Clisu, C; Jeppesen, H B; Wu, C; Pain, S D; Stracener, D W; Wuosmaa, A H; Szilner, S; Colovic, P; Matousek, V; Venhart, M; Birova, M; Li, X; Stuchbery, A E; Lellep, G M; Chakraborty, S; Leoni, S; Chupp, T; Yilmaz, C; Severin, G; Garcia ramos, J E; Newton, M E; Hadinia, B; Mc glynn, E; Monteiro de sena silvares de carvalho, I; Friedag, P; Figuera, P; Koos, V; Meot, V H; Pauwels, D B; Jancso, A; Srebrny, J; Alves, E J; David bosne, E; Bengtsson, L; Kalkuehler, M; Albers, M; Bharuth-ram, K; Akkus, B; Hemmingsen, L B S; Pedersen, J T; Dos santos redondo, L M; Rubio barroso, B; Algora, A; Kozlov, V; Mavela, D L; Mokhles gerami, A; Keeley, N; Bernardo da silva, E; Unzueta solozabal, I; Schell, J; Szybowicz, M; Yang, X; Plavec, J; Lassen, J; Johnston, K; Coquard, L; Bloch, T P; Bonig, E S; Stegmann, R; Ignatov, A; Paschalis, S; Fernandez martinez, G; Schilling, M; Habermann, T; Von hahn, R; Minaya ramirez, E E; Moore, I D; Wang, Y; Saastamoinen, A J; Grahn, T; Herzan, A; Stolze, S M; Clement, E; Dijon, A; Shornikov, A; Lienard, E; Gibelin, J D; Pain, C; Canchel, G; Simpson, G S; Latrasse, L P; Huang, W; Forest, D H; Billowes, J; Flanagan, K; Strashnov, I; Binnersley, C L; Sanchez poncela, M; Simpson, J; Morrall, P S; Grant, A F; Charisopoulos, S; Lagogiannis, A; Bhattacharya, C; Olafsson, S; Stepaniuk, M; Tornqvist, H T; Heinz, A M; White iv, E R; Courtin, S; Marechal, F; Da silva fenta, A E; De lemos lima, T A; Stryjczyk, M; Dockx, K; Haller, S; Rizzi, M; Reichert, S B; Bonn, J; Thirolf, P G; Garcia rios, A R; Gugliermina, V M; Cubero campos, M A; Sanchez tembleque, V; Benito garcia, J; Senoville, M; Mountford, D J; Gelletly, W; Alharbi, T S T; Wilson, E; Rigby, S V; Andreoiu, C; Paul, E S; Harkness, L J; Judson, D S; Wraith, C; Van esbroeck, K; Wadsworth, R; Cubiss, J G; Harding, R D; Vaintraub, S; Mandal, S K; Scarpa, D; Hoff, P; Syed naeemul, H; Borcea, R; Balabanski, D L; Marginean, R; Rotaru, F; Rudolph, D; Fahlander, C H; Chudoba, V; Kay, B P; Soic, N; Naidoo, D; Veselsky, M; Kliman, J; Raisanen, J A; Dietrich, M; Maung maung than, M M T; Reed, M W; Danchev, M T; Ray, J; Roy, M; Hammen, M; Capponi, L; Veghne csatlos, M M; Fryar, J; Mirzadeh vaghefi, S P; Trindade pereira, A M; De pinho oliveira, G N; Bakenecker, A; Tramm, C; Germic, V; Morel, P A; Kowalczyk, M; Matejska-minda, M; Wolinska-cichocka, M; Ringvall moberg, A; Mantovan, R; Fransen, C H; Radeck, F; Schneiders, D W; Steinbach, T; Vibenholt, J E; Magnussen, M J; Stevnhoved, H M; Comas lijachev, V; Dasenbrock-gammon, N M; Perkowski, J; O'neill, G G; Matveev, Y; Wegner, M; Liu, Z; Perez alvarez, T; Cerato, L; Radchenko, V; Molholt, T E; Tabares giraldo, J A; Srnka, D; Dlouhy, Z; Beck, D; Werner, V R; Homm, I; Eliseev, S; Blaum, K; Probst, M B; Kaiser, C J; Martin, J A; Refsgaard, J; Peura, P J; Greenlees, P T; Auranen, K; Delahaye, P; Traykov, E K; Perez loureiro, D; Mery, A A; Couratin, C; Tsekhanovich, I; Lunney, D; Gaulard, C V; Mottram, A D; Cullen, D M; Das, S K; Van de walle, J; Mazzocchi, C; Jonson, B N G; Woehr, A; Lesher, S R; Zuber, K T; Filippin, L; De witte, H J; Van den bergh, P A M; Raabe, R; Dirkx, D; Parnefjord gustafsson, F O A; Dunlop, R A; Tarasava, K; Gernhaeuser, R A; Weinzierl, W; Berger, C; Wendt, K; Achtzehn, T; Gottwald, T; Schug, M; Rossel, R E; Dominguez reyes, R R; Fraile prieto, L M; Briz monago, J A; Koester, U H; Bunce, M R; Bowry, M D; Nakhostin, M; Shearman, R; Cresswell, J R; Joss, D T; Gredley, A; Groombridge, D; Laird, A M; Aslanoglou, X; Siem, S; Weterings, J A; Renstrom, T; Szpak, B T; Luczkowski, M J; Ghita, D; Bezbakh, A; Soltz, R A; Bollmann, J; Bhattacharya, P; Roy, S; Rahaman, M A; Wlodarski, T; Carvalho soares, J; Barzakh, A; Schertz, F; Froemmgen, N E; Liberati, V; Foy, B E; Baptista barbosa, M; Weinheimer, C P; Zboril, M; Simon, R E; Popescu, L A; Czosnyka, T; Miranda jana, P A; Leimbach, D; Naskrecki, R; Plociennik, W A; Ruchowska, E E; Chiara, C J; Walters, W; Eberth, J H; Thomas, T; Thole, P; Queiser, M T; Lo bianco, G; D'amico, F; Muller, S; Sanchez alarcon, R M; Tain enriquez, J L; Orrigo, S E A; Orlandi, R; Masango, S; Plazaola muguruza, F C; Lepareur, N G; Fiebig, J M; Ceylan, N; Wildner, E; Kowalska, M; Malbrunot, S; Garcia ruiz, R F; Pallada, S; Slezak, M; Roeckl, E; Schrieder, G H; Ilieva, S K; Koenig, K L; Amoretti, M A; Lommen, J M; Fynbo, H O U; Weyer, G O P; Koldste, G T; Madsboll, K; Jensen, J H; Nieminen, A M; Reponen, M; Villari, A; Thomas, J; Saint-laurent, M; Sorlin, O H; Carniol, B; Pereira lopez, J; Grevy, S; Plaisir, C; Marie-jeanne, M J; Georgiev, G P; Etile, A M; Le blanc, F M; Verney, D; Stefan, G I; Assie, M; Suzuki, D; Guillot, J; Vazquez rodriguez, L; Campbell, P; Deacon, A N; Ware, T; Flueras, A; Xie, L; Banerjee, K; Piersa, M; Galaviz redondo, D; Johansson, H T; Schwarz, S; Toysa, A S; Aumont, J; Van duppen, P L E; Atanasov, D; Zadvornaya, A; Renaud, M A; Xu, Z; Garrett, P E; Rapisarda, E; Reber, J A; Mattolat, C F; Raeder, S; Habs, D; Vidal, M; Perez liva, M; Calvo portela, P; Ulla pedrera, F J; Wood, R T; Lalkovski, S; Page, R; Petri, M; Barton, C J; Nichols, A J; Vermeulen, M J; Bloor, D M; Henderson, J; Wilson, G L; De angelis, G; Buerger, A; Modamio hoybjor, V; Klintefjord, M L; Ingeberg, V W; Fornal, B A; Marginean, R; Sava, T; Kusoglu, A; Suvaila, R; Lica, R; Costache, C; Mihai, R; Ionescu, A; Baeck, T M; Hoffman, C R; Sedlak, M; Koskelo, O K; Kyaw myat, K M; Gladnishki, K A; Ganguly, B; Goncalves marques, J; Cardoso, S; Seliverstov, M; Niessen, B D; Gutt, L E; Chapman, R; Spagnoletti, P N; Lopes, C; De oliveira amorim, C; Batista lopes, C M; Araujo, J; Schielke, S J; Daugas, J R; Gaudefroy, L; Chevrier, R; Szunyogh, D M; Napiorkowski, P J; Wrzosek-lipska, K; Wahl, U; Catarino, N; Pereira carvalho alves de sequeira, M; Hess, H E; Holler, A; Bettermann, L; Geibel, K; Taprogge, J; Lewandowski, L T N; Manchado de sola, F; Cakirli mutlu, R B; Das gupta, S; Thulstrup, P W; Heinz, U; Nogwanya, T; Neidherr, D M; Morales lopez, A I; Gumenyuk, O; Peaker, A R; Wakabayashi, Y; Abrahams, K J; Martin montes, E J; Mach, H A; Souza ribeiro junior, I; He, J; Chalil, A; Xing, R; Dos santos augusto, R M; Giles, T J; Dorsival, A; Trujillo hernandez, J S; Kalaninova, Z; Andel, B; Venos, D; Kraemer, J; Saha, S; Neugart, R; Eronen, T O; Kreim, K D; Heck, M K; Goncharov, M; Karthein, J; Julin, R J; Eleon, C; Achouri, N L; Grinyer, G F; Fontbonne, C M; Alfaurt, P; Lynch, K M; Wilkins, S G; Brown, A R; Imai, N; Pomorski, M J; Janiak, L; Nilsson, T; Stroke, H H; Stanja, J; Dangelser, E; Heenen, P; Godefroid, M; Mallion, S N; Gins, W A M; Stegemann, S T; Koszorus, A; Mcnulty, J F; Lin, P; Ohlert, C M; Schwerdtfeger, W; Tengblad, O; Becerril reyes, A D; Perea martinez, A; Martinez perez, M C; Margerin, V; Rudigier, M; Alexander, T D; Patel, Z V; Hammond, N; Wearing, F; Patel, A; Jenkins, D G; Corradi, L; Galtarossa, F; Debernardi, A; Giacoppo, F; Tveten, G M; Malatji, K L; Krolas, W A; Stanoiu, M A; Rickert, E U; Ter-akopian, G; Cline, D; Riihimaeki, I A; Simon, K D; Wagner, F E; Turker, M; Neef, M H; Coombes, B J; Jakubek, J; Vagena, E; Bottoni, S; Nishimura, K; Correia, J; Rodrigues valdrez, C J; Molkanov, P; Adhikari, R; Ostrowski, A N; Hallmann, O; Scheck, M; Wady, P T; Lane, J; Krasznahorkay, A J; Kunne sohler, D; Meaney, A J; Hochschulz, F; Roig, O; Behan, C C; Kargoll, S; Kemnitz, S; Carvalho teixeira, R C; Redondo cubero, A; Tallarida, G; Kaczarowski, R; Finke, F; Linnemann, A; Altenkirch, R; Saed-samii, N; Ansari, S H; Dlamini, W B; Adoons, V N; Ronning, C R; Wiedeking, M; Herlert, A J; Mehl, C V; Judge, S M; Gaertner, D; Divinskyi, S; Karabasov, M O; Zagoraios, G; Boztosun, I; Van zyl, J J; Catherall, R; Lettry, J; Wenander, F J C; Zakoucky, D; Catchen, G L; Noertershaeuser, W; Kroell, T; Leske, J; Shubina, D; Murray, I M; Pancin, J; Delaunay, F; Poincheval, J J L; Audirac, L L; Gerbaux, M T; Aouadi, M; Sole, P G P; Fallot, M P; Onillon, A; Duchemin, C; Formento cavaier, R; Audi, G; Boukhari, A; Lau, C; Martin, J A; Barre, N H; Berry, T A; Procter, T J; Bladen, L K; Axiotis, M; Muto, S; Jeong, S C; Hirayama, Y; Korgul, A B; Minamisono, K; Bingham, C R; Aprahamian, A; Bucher, B M; Severijns, N; Huyse, M L; Ferrer garcia, R; Verlinde, M N S; Romano, N; Maugeri, E A; Klupp, S C; Dehn, M H; Heinke, R M; Naubereit, P; Maira vidal, A; Vedia fernandez, M V; Ibanez garcia, P B; Bruyneel, B J E; Materna, T; Hadynska-klek, K; Al-dahan, N; Alazemi, N; Carroll, R J; Babcock, C; Patronis, N; Eleme, Z; Dhal, A; Sahin, E; Goergen, A; Maj, A; Bednarczyk, P A; Borcea, C; Negoita, F; Suliman, G; Marginean, N M; Sotty, C O; Negret, A L; Nae, S A; Nita, C; Golubev, P I; Knyazev, A; Jost, C U; Petrik, K; Vaeyrynen, S A; Dracoulis, G D; Uher, J; Fernandez dominguez, B; Chakraborty, P; Avigo, R; Falahat, S; Lekovic, F; Dorrer, H J; Mengoni, D; Derkx, X; Angus, L J; Sandhu, K S; Gregor, E; Kelly, N A; Byrne, D J; Haas, H; Lourenco, A A; Sousa pereira, S M; Sousa, J B; De melo mendonca, T M; Tavares de sousa, C; Guerreiro dos santos oliveira custodio, L M; Da rocha rodrigues, P M; Yamaguchi, T; Thompson, P C; Rosenbusch, M; Wienholtz, F; Fischer, P; Iwanicki, J S; Rusek, K M; Hanstorp, D; Vetter, U; Wolak, J M; Park, S H; Warr, N V; Doornenbal, P C; Imig, A; Seidlitz, M; Moschner, K; Vogt, A; Kaya, L; Martel bravo, I; Orduz, A K; Serot, O; Majola, S N; Litvinov, Y; Bommert, M; Hensel, S; Markevich, V; Nishio, K; Ota, S; Matos, I; Zenkevich, A; Picado sandi, E; Forstner, O; Hu, B; Ntshangase, S S; Sanchez-segovia, J

    2002-01-01

    The experiments aim at a broad exploration of the properties of atomic nuclei far away from the region of beta stability. Furthermore, the unique radioactive beams of over 60~elements produced at the on-line isotope separators ISOLDE-2 and ISOLDE-3 are used in a wide programme of atomic, solid state and surface physics. Around 300 scientists are involved in the project, coming from about 70 laboratories. \\\\ \\\\ The electromagnetic isotope separators are connected on-line with their production targets in the extracted 600 MeV proton or 910~MeV Helium-3 beam of the Synchro-Cyclotron. Secondary beams of radioactive isotopes are available at the facility in intensities of 10$^1

  20. Police Enforcement Policy and Programmes on European Roads (PEPPER). Deliverable 4a: Good practice in data, data collection and data use for monitoring and evaluating Traffic Law Enforcement.

    NARCIS (Netherlands)

    Schagen, I.N.L.G. Bernhoft, I.M. Erke, A. Ewert, U. Kallberg, V.-P. & Skladana, P.

    2008-01-01

    This report is the Deliverable of task 4.3a of the PEPPER project. It describes the good practice requirements regarding data, data collection and data use for monitoring and evaluating Traffic Law Enforcement (TLE). The aim is that, eventually, individual police forces/countries put the identified

  1. Validation and operational measurements with SUSIE – A sar ice motion processing chain developed within promice (Programme for monitoring of Greenland ice-sheet)

    DEFF Research Database (Denmark)

    Merryman Boncori, John Peter; Dall, Jørgen; Ahlstrøm, A. P.

    2010-01-01

    This paper describes the validation of an ice-motion processing chain developed for the PROMICE project – a long-term program funded by the Danish ministry of Climate and Energy to monitor the mass budget of the Greenland ice-sheet. The processor, named SUSIE, (Scripts and Utilities for SAR Ice...

  2. Radiation safety aspects of fluorescent lamp starters incorporating radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Sadagopan, Geetha [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Shukla, V.K. [Environmental Assessment Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2000-05-01

    A fluorescent lamp starter is a switch applies the voltage to the fluorescent tube after sufficient preheating to allow the tube to conduct an electric current. Radioactive substances used in the starters are {sup 85}Kr, {sup 147}Pm, {sup 3}H and {sup 232}Th. In India, fluorescent lamp starters are classified as consumer products and users are outside regulatory control. However, regulatory control is exercised over the manufacturers at the production stage. Tritium activity measured in the lamp starters ranged from 400-4500 Bq with a mean activity of 1.78 kBq. Thorium activity measured varied from 0.44-3.3 mg. The results of radiation safety assessment of the workplace and radioactivity estimation in the starters are discussed in this paper. (author)

  3. Radiation safety aspects of fluorescent lamp starters incorporating radiation source

    International Nuclear Information System (INIS)

    Sadagopan, Geetha; Shukla, V.K.

    2000-01-01

    A fluorescent lamp starter is a switch applies the voltage to the fluorescent tube after sufficient preheating to allow the tube to conduct an electric current. Radioactive substances used in the starters are 85 Kr, 147 Pm, 3 H and 232 Th. In India, fluorescent lamp starters are classified as consumer products and users are outside regulatory control. However, regulatory control is exercised over the manufacturers at the production stage. Tritium activity measured in the lamp starters ranged from 400-4500 Bq with a mean activity of 1.78 kBq. Thorium activity measured varied from 0.44-3.3 mg. The results of radiation safety assessment of the workplace and radioactivity estimation in the starters are discussed in this paper. (author)

  4. Environmental radioactivity surveillance programme 1988-89

    International Nuclear Information System (INIS)

    Sequeira, S.; Pollard, D.; Hayden, E.; Dunne, B.; Colgan, P.A.; Cunningham, J.D.

    1990-06-01

    The Nuclear Energy Board measures radionuclides in air, rainwater, total fallout, drinking water supplies and milk as part of its programme to monitor radioactivity in the Irish environment. The report presents the results of measurements made during 1988 and 1989

  5. How to improve communication for the safe use of medicines?: Discussions on social marketing and patient-tailored approaches at the annual meetings of the WHO Programme for International Drug Monitoring.

    Science.gov (United States)

    Bahri, Priya; Harrison-Woolrych, Mira

    2012-12-01

    Over the past decade, the annual meetings of national centres participating in the WHO Programme for International Drug Monitoring have increasingly included discussions on how to improve communication between national pharmacovigilance centres, patients, healthcare professionals, policy makers and the general public, with the aim of promoting the safe use of medicines. At the most recent meetings, working groups were dedicated to discuss possible applications and implementation of social marketing and patient-tailored approaches. This article provides the history and a summary of the recent discussions and recommendations to support progress in this respect at national and global level. Recommendations are made to investigate and pilot these approaches in small-scale projects at national pharmacovigilance centres. Applying elements from the social marketing and patient-tailored approaches to support behaviours of safe medicines use in patients and healthcare professionals should give the pharmacovigilance community new tools to achieve their goal to minimize risks with medicines and improve patient safety.

  6. Investigating antennas as ignition aid for automotive HID lamps

    International Nuclear Information System (INIS)

    Bergner, A; Engelhardt, M; Bienholz, S; Ruhrmann, C; Hoebing, T; Groeger, S; Mentel, J; Awakowicz, P

    2015-01-01

    This paper considers the ignition of mercury-free high-intensity discharge (HID) lamps for car headlights. Due to safety reasons, these lamps need to have a fast run-up phase which is ensured, amongst other things, by a high Xe pressure of roughly 15 bar (cold) in the discharge vessel. The high Xe pressure causes an increased ignition voltage compared with former mercury-containing automotive HID lamps or low-pressure lamps used for general-lighting applications. The increase in ignition voltage can be limited if the electric field in front of the electrodes is raised by an uplifting of the electrical conductivity along the outer wall of the inner bulb either by a conductive layer on its surface or by a dielectric barrier discharge (DBD) within the outer bulb. This paper considers on the one hand conventional antennas deposited by physical vapour deposition (PVD) and on the other hand a combination of these antennas with a DBD within the outer-bulb operated in 100 mbar Ar as ignition aids. In both cases the antenna potential and antenna width are varied. Additionally, the effects of antenna thickness and antenna material are investigated. The ignition voltage, ignition current and light emission during ignition are measured on a nanosecond timescale. Furthermore, for the very first time, the ignition process is recorded in four consecutive intensified charge-coupled device images using a high-speed camera system with a time resolution in the range of nanoseconds. It was found that antennas strongly reduce the ignition voltage of automotive HID lamps. Active antennas reduce the ignition voltage significantly more than passive antennas, proportional to the conductance of the antenna. Combining conventional antennas with an outer-bulb discharge reduces the ignition voltage from 19 kV without any ignition aid to the intrinsic ignition voltage of the lamp below 10 kV, in the best case. (paper)

  7. A new Cassegrain calibration lamp unit for the Blanco Telescope

    Science.gov (United States)

    Points, S. D.; James, D. J.; Tighe, R.; Montané, A.; David, N.; Martínez, M.

    2016-08-01

    The f/8 RC-Cassegrain Focus of the Blanco Telescope at Cerro Tololo Inter-American Observatory, hosts two new instruments: COSMOS, a multi-object spectrograph in the visible wavelength range (350 - 1030nm), and ARCoIRIS, a NIR cross-dispersed spectrograph featuring 6 spectral orders spanning 0.8 - 2.45μm. Here we describe a calibration lamp unit designed to deliver the required illumination at the telescope focal plane for both instruments. These requirements are: (1) an f/8 beam of light covering a spot of 92mm diameter (or 10 arcmin) for a wavelength range of 0.35μm through 2.5μm and (2) no saturation of flat-field calibrations for the minimal exposure times permitted by each instrument, and (3) few saturated spectral lines when using the wavelength calibration lamps for the instruments. To meet these requirements this unit contains an adjustable quartz halogen lamp for flat-field calibrations, and one hollow cathode lamp and four penray lamps for wavelength calibrations. The wavelength calibration lamps are selected to provide optimal spectral coverage for the instrument mounted and can be used individually or in sets. The device designed is based on an 8-inch diameter integrating sphere, the output of which is optimized to match the f/8 calibration input delivery system which is a refractive system based on fused-silica lenses. We describe the optical design, the opto-mechanical design, the electronic control and give results of the performance of the system.

  8. TELEGRAPHS TO INCANDESCENT LAMPS: A SEQUENTIAL PROCESS OF INNOVATION

    Directory of Open Access Journals (Sweden)

    Laurence J. Malone

    2000-01-01

    Full Text Available This paper outlines a sequential process of technological innovation in the emergence of the electrical industry in the United States from 1830 to 1880. Successive inventions that realize the commercial possibilities of electricity provided the foundation for an industry where technical knowledge, invention and diffusion were ultimately consolidated within the managerial structure of new firms. The genesis of the industry is traced, sequentially, through the development of the telegraph, arc light and incandescent lamp. Exploring the origins of the telegraph and incandescent lamp reveals a process where a series of inventions and firms result from successful efforts touse scientific principles to create new commodities and markets.

  9. Very high efficacy electrodeless high intensity discharge lamps

    Science.gov (United States)

    Johnson, Peter D.

    1987-01-01

    An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

  10. Inventing around Edison’s Incandescent Lamp Patent

    DEFF Research Database (Denmark)

    Howells, John; Katznelson, Ron D.

    ’s ‘898 patent. Third, by analysis of forward citation to these patents we show that regardless of these inventions’ commercial viability in the incandescent lamp market, some became important prior art for new technological fields and some laid the groundwork for the later successful substitute...... for Edison’s carbon filament. Fourthly, we show that the recent view that Edison’s patent gave the patent holder General Electric (GE) a dominant position in the incandescent lamp market is incorrect: we show that besides commercially-successful invention around the claims of this patent, data for GE...

  11. Inventing around Edison’s incandescent lamp patent

    DEFF Research Database (Denmark)

    Howells, John; Ron D, Katznelson

    ’s ‘898 patent. Third, by analysis of forward citation to these patents we show that regardless of these inventions’ commercial viability in the incandescent lamp market, some became important prior art for new technological fields and some laid the groundwork for the later successful substitute...... for Edison’s carbon filament. Fourthly, we show that the recent view that Edison’s patent gave the patent holder General Electric (GE) a dominant position in the incandescent lamp market is incorrect: we show that besides commercially-successful invention around the claims of this patent, data for GE...

  12. Physical aspects of mercury-free high pressure discharge lamps

    International Nuclear Information System (INIS)

    Born, M.

    2002-01-01

    This paper gives a summary of recent results about the replacement of mercury in high pressure discharge lamps by metallic zinc. Actually, this topic is of high relevance for the lighting industry due to the need of more environmentally friendly products. The work presented here is supported by the German government under contract no. 13N8072. Pure zinc/argon discharges as well as lamps including zinc or mercury and metal halide additives are investigated. Experimental data are compared with model calculations of the energy balance involving the transport of heat and radiation. Since the excitation energies of relevant zinc transistions are lower than for mercury, axis temperatures of pure zinc lamps are about 300 K below the value of mercury arcs. In addition, the thermal conductivity of zinc including the contribution of radiation diffusion is larger than compared to mercury. From lamp voltage measurements it is found that the cross section for elastical electron scattering by zinc atoms is about the same as for mercury. When adding metal halides to a pure zinc discharge with argon as a starting gas, i.e. NaI, TlI, DyI3, axis temperatures decrease to about 5100 K due to strong radiation cooling. In order to obtain sufficiently large lamp voltages, wall temperatures of more than 1300 K are adjusted by means of polycrystalline aluminaoxide (Al2O3) as a wall material. Electrical field strenghts of 6.0 V/mm and 8.6 V/mm are measured for metal halide lamps containing zinc or mercury, respectively. The light technical data of the discharges are very close, since mercury and zinc do not contribute significantly to the radiation in the visible range. Efficacies of up to 93 lm/W and 100 lm/W are found in metal halide lamps with zinc and mercury, respectively. Consequently, zinc turns out to be an attractive replacer for mercury in this type of lamp not only from an environmental point of view

  13. Developing human rights based indicators to support country monitoring of rehabilitation services and programmes for people with disabilities: a study protocol.

    Science.gov (United States)

    Skempes, Dimitrios; Bickenbach, Jerome

    2015-09-24

    Rehabilitation care is fundamental to health and human dignity and a human right enshrined in the United Nations Convention on the Rights of Persons with Disabilities. The provision of rehabilitation is important for reducing the need for formal support and enabling persons with disabilities to lead an independent life. Increasingly scholars and advocacy groups voice concerns over the significant barriers facing people with disabilities in accessing appropriate and quality rehabilitation. A growing body of research highlights a "respond-need" gap in the provision of rehabilitation and assistive technologies and underscore the lack of indicators for assessing performance of rehabilitation systems and monitoring States compliance with human rights standards in rehabilitation service planning and programming. While research on human rights and health monitoring has increased exponentially over the last decade far too little attention has been paid to rehabilitation services. The proposed research aims to reduce this knowledge gap by developing a human rights based monitoring framework with indicators to support human rights accountability and performance assessment in rehabilitation. Concept mapping, a stakeholder-driven approach will be used as the core method to identify rights based indicators and develop the rehabilitation services monitoring framework. Concept mapping requires participants from various stakeholders groups to generate a list of the potential indicators through on line brainstorming, sort the indicators for conceptual similarity into clusters and rate them against predefined criteria. Multidimensional scaling and hierarchical cluster data analysis will be performed to develop the monitoring framework while bridging analysis will provide useful insights about patterns of agreement or disagreement among participants views on indicators. This study has the potential to influence future practices on data collection and measurement of compliance with

  14. Lot quality assurance sampling for monitoring coverage and quality of a targeted condom social marketing programme in traditional and non-traditional outlets in India

    OpenAIRE

    Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal

    2010-01-01

    Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in...

  15. The feasibility of measuring and monitoring social determinants of health and the relevance for policy and programme - a qualitative assessment of four countries.

    Science.gov (United States)

    Blas, Erik; Ataguba, John E; Huda, Tanvir M; Bao, Giang Kim; Rasella, Davide; Gerecke, Megan R

    2016-01-01

    Since the publication of the reports by the Commission on Social Determinants of Health (CSDH), many research papers have documented inequities, explaining causal pathways in order to inform policy and programmatic decision-making. At the international level, the sustainable development goals (SDGs) reflect an attempt to bring together these themes and the complexities involved in defining a comprehensive development framework. However, to date, much less has been done to address the monitoring challenges, that is, how data generation, analysis and use are to become routine tasks. To test proposed indicators of social determinants of health (SDH), gender, equity, and human rights with respect to their relevance in tracking progress in universal health coverage and population health (level and distribution). In an attempt to explore these monitoring challenges, indicators covering a wide range of social determinants were tested in four country case studies (Bangladesh, Brazil, South Africa, and Vietnam) for their technical feasibility, reliability, and validity, and their communicability and usefulness to policy-makers. Twelve thematic domains with 20 core indicators covering different aspects of equity, human rights, gender, and SDH were tested through a review of data sources, descriptive analyses, key informant interviews, and focus group discussions. To test the communicability and usefulness of the domains, domain narratives that explained the causal pathways were presented to policy-makers, managers, the media, and civil society leaders. For most countries, monitoring is possible, as some data were available for most of the core indicators. However, a qualitative assessment showed that technical feasibility, reliability, and validity varied across indicators and countries. Producing understandable and useful information proved challenging, and particularly so in translating indicator definitions and data into meaningful lay and managerial narratives, and

  16. The feasibility of measuring and monitoring social determinants of health and the relevance for policy and programme – a qualitative assessment of four countries

    Directory of Open Access Journals (Sweden)

    Erik Blas

    2016-02-01

    Full Text Available Background: Since the publication of the reports by the Commission on Social Determinants of Health (CSDH, many research papers have documented inequities, explaining causal pathways in order to inform policy and programmatic decision-making. At the international level, the sustainable development goals (SDGs reflect an attempt to bring together these themes and the complexities involved in defining a comprehensive development framework. However, to date, much less has been done to address the monitoring challenges, that is, how data generation, analysis and use are to become routine tasks. Objective: To test proposed indicators of social determinants of health (SDH, gender, equity, and human rights with respect to their relevance in tracking progress in universal health coverage and population health (level and distribution. Design: In an attempt to explore these monitoring challenges, indicators covering a wide range of social determinants were tested in four country case studies (Bangladesh, Brazil, South Africa, and Vietnam for their technical feasibility, reliability, and validity, and their communicability and usefulness to policy-makers. Twelve thematic domains with 20 core indicators covering different aspects of equity, human rights, gender, and SDH were tested through a review of data sources, descriptive analyses, key informant interviews, and focus group discussions. To test the communicability and usefulness of the domains, domain narratives that explained the causal pathways were presented to policy-makers, managers, the media, and civil society leaders. Results: For most countries, monitoring is possible, as some data were available for most of the core indicators. However, a qualitative assessment showed that technical feasibility, reliability, and validity varied across indicators and countries. Producing understandable and useful information proved challenging, and particularly so in translating indicator definitions and data

  17. LAVA: An Open-Source Approach To Designing LAMP (Loop-Mediated Isothermal Amplification DNA Signatures

    Directory of Open Access Journals (Sweden)

    Gardner Shea N

    2011-06-01

    Full Text Available Abstract Background We developed an extendable open-source Loop-mediated isothermal AMPlification (LAMP signature design program called LAVA (LAMP Assay Versatile Analysis. LAVA was created in response to limitations of existing LAMP signature programs. Results LAVA identifies combinations of six primer regions for basic LAMP signatures, or combinations of eight primer regions for LAMP signatures with loop primers, which can be used as LAMP signatures. The identified primers are conserved among target organism sequences. Primer combinations are optimized based on lengths, melting temperatures, and spacing among primer sites. We compare LAMP signature candidates for Staphylococcus aureus created both by LAVA and by PrimerExplorer. We also include signatures from a sample run targeting all strains of Mycobacterium tuberculosis. Conclusions We have designed and demonstrated new software for identifying signature candidates appropriate for LAMP assays. The software is available for download at http://lava-dna.googlecode.com/.

  18. NOVANA. National Monitering and Assessment Programme for the Aquatic and Terrestrial Environments

    DEFF Research Database (Denmark)

    Svendsen, L. M.; Bijl, L. van der; Boutrup, S.

    This report is Part 2 of the Programme Description of NOVANA - the National Monitoring and Assessment Programme for the Aquatic and Terrestrial Environments. Part 2 comprises a de-tailed description of the nine NOVANA subprogrammes: Background monitoring of air......This report is Part 2 of the Programme Description of NOVANA - the National Monitoring and Assessment Programme for the Aquatic and Terrestrial Environments. Part 2 comprises a de-tailed description of the nine NOVANA subprogrammes: Background monitoring of air...

  19. Technology programme

    International Nuclear Information System (INIS)

    2007-01-01

    The technology activities carried out by the EURATOM-ENEA Association concern the continuation of the European Fusion Development Agreement (EFDA) as well as the ITER activities coordinated by the ITER International Office and Fusion for Energy. Also included in the activities are design and RD under the Broader Approach Agreement between the EU and Japan. In order to better contribute to the programme a number of consortium agreements among the Associations are being signed. Collaboration with industries in view of their participation in the construction of ITER was further strengthened, mainly in the field of magnet and divertor components. The new European Test Blanket Facility at ENEA Brasimone was completed; the design of the ITER radial neutron camera was optimised and the performance achievable with the in-vessel viewing system was further assessed by experimental trials. Design activities for the JT-60SA magnet and power supply system as well as the design and experimental activities related to the target of the International Fusion Materials Irradiation Facility were continued. Significant work was done to define quality assurance for neutronics analyses. Mockups of the ITER pre-compression ring made in glass fibre epoxy were tested. The activities and results documented in the following illustrate ENEA's efforts to support fusion development

  20. Influence of electrode, buffer gas and control gear on metal halide lamp performance

    International Nuclear Information System (INIS)

    Lamouri, A; Naruka, A; Sulcs, J; Varanasi, C V; Brumleve, T R

    2005-01-01

    In this paper the influence of electrode composition, buffer gas fill pressure and control gear on the performance of metal halide lamps is investigated. It is shown that pure tungsten electrodes improve lumen maintenance and reduce voltage rise over lamp life. An optimum buffer gas fill pressure condition is discovered which allows for reduced electrode erosion during lamp starting as well as under normal operating conditions. Use of electronic control gear is shown to improve the performance of metal halide lamps

  1. Lysosome associated membrane proteins maintain pancreatic acinar cell homeostasis: LAMP-2 deficient mice develop pancreatitis.

    Science.gov (United States)

    Mareninova, Olga A; Sendler, Matthias; Malla, Sudarshan Ravi; Yakubov, Iskandar; French, Samuel W; Tokhtaeva, Elmira; Vagin, Olga; Oorschot, Viola; Lüllmann-Rauch, Renate; Blanz, Judith; Dawson, David; Klumperman, Judith; Lerch, Markus M; Mayerle, Julia; Gukovsky, Ilya; Gukovskaya, Anna S

    2015-11-01

    The pathogenic mechanism of pancreatitis is poorly understood. Recent evidence implicates defective autophagy in pancreatitis responses; however, the pathways mediating impaired autophagy in pancreas remain largely unknown. Here, we investigate the role of lysosome associated membrane proteins (LAMPs) in pancreatitis. We analyzed changes in LAMPs in experimental models and human pancreatitis, and the underlying mechanisms: LAMP de-glycosylation and degradation. LAMP cleavage by cathepsin B (CatB) was analyzed by mass spectrometry. We used mice deficient in LAMP-2 to assess its role in pancreatitis. Pancreatic levels of LAMP-1 and LAMP-2 greatly decrease across various pancreatitis models and in human disease. Pancreatitis does not trigger LAMPs' bulk de-glycosylation, but induces their degradation via CatB-mediated cleavage of LAMP molecule close to the boundary between luminal and transmembrane domains. LAMP-2 null mice spontaneously develop pancreatitis that begins with acinar cell vacuolization due to impaired autophagic flux, and progresses to severe pancreas damage characterized by trypsinogen activation, macrophage-driven inflammation, and acinar cell death. LAMP-2 deficiency causes a decrease in pancreatic digestive enzymes content, stimulates the basal and inhibits CCK-induced amylase secretion by acinar cells. The effects of LAMP-2 knockout and acute cerulein pancreatitis overlap, which corroborates the pathogenic role of LAMP decrease in experimental pancreatitis models. The results indicate a critical role for LAMPs, particularly LAMP-2, in maintaining pancreatic acinar cell homeostasis, and provide evidence that defective lysosomal function, resulting in impaired autophagy, leads to pancreatitis. Mice with LAMP-2 deficiency present a novel genetic model of human pancreatitis caused by lysosomal/autophagic dysfunction.

  2. Development of in-field monitoring techniques. Report on Task FIN A845 on the Finnish Support Programme to IAEA Safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, H; Honkamaa, T; Kansanaho, A; Poellaenen, R [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland). Aerosol Lab.; Aarnio, P; Ala-Heikkilae, J; Nikkinen, M [Helsinki Univ. of Technology, Otaniemi (Finland). Nuclear Engineering Lab.

    1994-12-01

    Several in-field measuring techniques were identified for use in safeguards inspections. The radiation measurements play a major role in seeking environmetal signatures. A high-resolution gamma-ray spectrometer, either in-situ or in sample analysis, gives unequivocal evidence of nuclear activities on the site of interest. Although portable spectrometers are commercially available, hardware development and software tailoring seem to be necessary before efficient mobile measurements can be initiated. To understand trends and pattern of contamination, the results of the measurements have be displayed on digital maps. GPS-integration is an essential requirement for the equipment in environmental monitoring. (orig.) (14 refs., 5 figs., 17 tabs.).

  3. Impacts of pollution on freshwater communities in the border region between Russia and Norway. Results of the 1990-96 monitoring programme

    International Nuclear Information System (INIS)

    Noest, Terje; Lukin, Anatoli; Schartau, Ann Kristin Lien; Kashulin, Nikolai; Berger, Hans Mack; Yakovlev, Valeri; Sharov, Andrey; Dauvalter, Vladimir

    1997-05-01

    This report summarises the results and conclusions of the investigations in the border region between Russia and Norway, primary in selected monitoring lakes during 1990-96. The results of the 1996 investigations are given a more thorough presentation. Results on species composition, abundances and biomasses of phytoplankton, zooplankton, benthos and fish communities, as well as population parameters (length and age distribution) for different fish species are presented. Pathological state and trace metal accumulation in fish are analysed. The biological results are related to analyses of chemical parameters in lake sediments and water. 46 refs., 12 figs., 6 tabs

  4. Development of in-field monitoring techniques. Report on Task FIN A845 on the Finnish Support Programme to IAEA Safeguards

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Kansanaho, A.; Poellaenen, R.; Aarnio, P.; Ala-Heikkilae, J.; Nikkinen, M.

    1994-12-01

    Several in-field measuring techniques were identified for use in safeguards inspections. The radiation measurements play a major role in seeking environmetal signatures. A high-resolution gamma-ray spectrometer, either in-situ or in sample analysis, gives unequivocal evidence of nuclear activities on the site of interest. Although portable spectrometers are commercially available, hardware development and software tailoring seem to be necessary before efficient mobile measurements can be initiated. To understand trends and pattern of contamination, the results of the measurements have be displayed on digital maps. GPS-integration is an essential requirement for the equipment in environmental monitoring. (orig.) (14 refs., 5 figs., 17 tabs.)

  5. Impacts of pollution on freshwater communities in the border region between Russia and Norway. Results of the 1990-96 monitoring programme

    Energy Technology Data Exchange (ETDEWEB)

    Noest, Terje; Lukin, Anatoli; Schartau, Ann Kristin Lien; Kashulin, Nikolai; Berger, Hans Mack; Yakovlev, Valeri; Sharov, Andrey; Dauvalter, Vladimir

    1997-05-01

    This report summarises the results and conclusions of the investigations in the border region between Russia and Norway, primary in selected monitoring lakes during 1990-96. The results of the 1996 investigations are given a more thorough presentation. Results on species composition, abundances and biomasses of phytoplankton, zooplankton, benthos and fish communities, as well as population parameters (length and age distribution) for different fish species are presented. Pathological state and trace metal accumulation in fish are analysed. The biological results are related to analyses of chemical parameters in lake sediments and water. 46 refs., 12 figs., 6 tabs.

  6. Keeleuuendusest sündis diplomilavastus / Anu Lamp

    Index Scriptorium Estoniae

    Lamp, Anu, 1958-

    2006-01-01

    24. märtsil esietendus teatris NO99 lavakunstikooli 22. lennu viimane diplomilavastus "Keeleuuenduse lõpmatu kurv". Lavastaja Anu Lamp räägib, kuidas sündis ja kuidas materjal Johannes Aaviku keeleuuendusest lavale jõudis

  7. Direct-current converter for gas-discharge lamps

    Science.gov (United States)

    Lutus, P.

    1980-01-01

    Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

  8. Thomson scattering measurements on an atmospheric Ar dc discharge lamp

    NARCIS (Netherlands)

    Zhu, Xiao-Yan; Redwitz, M.; Kieft, E.R.; Sande, van de M.J.; Mullen, van der J.J.A.M.

    2004-01-01

    Thomson scattering (TS) experiments have been performed in the region near the electrodes of a dc powered model lamp filled with 1-2 bar argon gas. In order to suppress the false stray light and Rayleigh scattered photons, a triple grating spectrograph was used. In this way the electron density and

  9. Nonlinear behavior in high-intensity discharge lamps

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  10. Anu Lamp õpetab presidendile kõnekunsti peensusi / Kadri Paas

    Index Scriptorium Estoniae

    Paas, Kadri, 1982-

    2007-01-01

    Näitleja Anu Lamp õpetab president Toomas Hendrik Ilvesele kaheksa akadeemilise tunni jooksul kõnelemisoskust. Vt. samas: Martti Kass. Presidendi hiiglaslik vastuvõtutelk võtab ilmet. Tartus hakati Vanemuise teatri külje alla hiigeltelki püstitama. Telgis surub president Toomas Hendrik Ilves 24. veebruaril 2007 kutsutud külaliste kätt

  11. Modeling of Kr-Xe discharge of excimer lamp

    Directory of Open Access Journals (Sweden)

    Belasri A.

    2013-03-01

    Full Text Available This paper reports the numerical simulation of Dielectric Barrier Discharge (DBD for Kr-Xe excilamp. The model of the discharge consists of three main modules: a plasma chemistry module, a circuit module and a Boltzmann equation module. The results predict the optimal operating conditions and describe the electrical and chemical properties of the KrXe* excimer lamp.

  12. CALiPER Special Summary Report: Retail Replacement Lamp Testing

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-04-01

    CALiPER testing has evaluated many products for commercial lighting markets and found some excellent performers. However, many of these are not available on the retail market. This special testing was undertaken to identify and test solid-state lighting (SSL) replacement lamp products that are available to the general public through retail stores and websites.

  13. Loop-mediated isothermal amplification (LAMP) based detection of ...

    African Journals Online (AJOL)

    SAM

    2014-05-07

    May 7, 2014 ... 2 months for growing in a culture. Therefore, to control .... The LAMP reaction is carried out in a 25 µL reaction mixture containing ..... J. Fish Dis. 32(6):491-497. Goto M, Honda E, Ogura A, Nomoto A, Hanaki K (2009). Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy ...

  14. Application of loop-mediated isothermal amplification (LAMP) of the ...

    African Journals Online (AJOL)

    Administrator

    2011-05-23

    May 23, 2011 ... evaluate the RIME - LAMP for the detection of T. evansi in naturally infected camels in Sudan. MATERIALS AND METHODS. Study design. Cross sectional ... from each camel using 5 ml disposable syringe. Three drops of the fresh collected blood were immediately placed in FTA card. (Whatman classic ...

  15. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    Czech Academy of Sciences Publication Activity Database

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, Jan; Koleska, M.; Voljanskij, A.

    2015-01-01

    Roč. 116, NOV (2015), s. 56-59 ISSN 0969-806X R&D Projects: GA TA ČR TA01010237; GA MŠk LM2011019 Institutional support: RVO:61389005 Keywords : fluorescent lamp * mercury measurement * neutron activation analysis * research reactor Subject RIV: BG - Nuclear , Atomic and Molecular Physics, Colliders Impact factor: 1.207, year: 2015

  16. 21 CFR 878.4630 - Ultraviolet lamp for dermatologic disorders.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultraviolet lamp for dermatologic disorders. 878.4630 Section 878.4630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... disorders is a device (including a fixture) intended to provide ultraviolet radiation of the body to...

  17. LOOP mediated isothermal AMPlification (LAMP) in diagnosis of ...

    African Journals Online (AJOL)

    We collected a quantity of 35 serum samples of HIVpositive patients and a number of 107 cerebrospinal fluid (CSF) samples of patients who had shown symptoms of meningitis. We designed target specific primers for PCR and LAMP techniques to trace C. neoformans and C. gattii. From the total 142 clinical specimens, five ...

  18. Nonlinear behavior in high-intensity discharge lamps

    NARCIS (Netherlands)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-01-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the

  19. Harmonics Study of Common Low Wattage LED Lamps

    Directory of Open Access Journals (Sweden)

    Ioan Dragoş Deaconu

    2017-11-01

    Full Text Available This article presents experimental data on Light Emitting Diode (LED lamps of low wattage that are commonly found both in commercial and residential applications. A comparison with the existing regulations is performed. The measurements are performed using power and energy quality analyzer intended also for avionic and military systems.

  20. Optimized elemental analysis of fluorescence lamp shredder waste.

    Science.gov (United States)

    Hobohm, Julia; Kuchta, Kerstin; Krüger, Oliver; van Wasen, Sebastian; Adam, Christian

    2016-01-15

    Fluorescence lamps contain considerable amounts of rare earth elements (REE). Several recycling procedures for REE recovery from spent lamps have been established. However, despite their economic importance, the respective recycling is scarce so far, with an REE recovery rate of less than 1%. A reliable analysis of REE and other relevant metals like Yttrium is crucial for a thorough and complete recovery process. This applies both to the solid matter and aqueous phase, since most of the recycling processes include wet-chemical steps. We tested seven different reagent mixtures for microwave-assisted digestion of fluorescent lamp shredder, including hydrofluoric acid, perchloric acid, and hydrogen peroxide. We determined the concentrations of 25 of the most relevant rare earth and other trace elements (Al, P, Ti, V, Cr, Fe, Ni, Cu, Ga, Ge, As, Y, Ag, Cd, Sn, Sb, La, Ce, Eu, Gd, Tb, W, Au, Hg, and Pb) in the respective dilutions. Two independent digestions, one a mixture of perchlorid/nitric/hydrofluoric acid and the other aqua regia, showed the highest concentrations of 23 of these elements, excluding only Sn and Tb. The REE concentrations in the tested lamp shredder sample (stated in g/kg) were 10.2 (Y), 12.1 (La), 7.77 (Ce), 6.91 (Eu), 1.90 (Gd), and 4.11 (Tb). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Evaluation on Glare from Vehicle Lamps and Effectiveness of Road Components as Glare Barriers

    NARCIS (Netherlands)

    Mangkuto, R.A.; Paripurna, A.; Soelami, F.X.N.

    2009-01-01

    Vehicle lamps are vital components which are required to ensure the driver’s safety, particularly at nighttime. However, vehicle lamps may cause glare which can reduce visibility and create discomfort. The objectives of this research are to evaluate glare from car headlamp and motorcycle lamps; and

  2. On the square arc voltage waveform model in magnetic discharge lamp studies

    OpenAIRE

    Molina, Julio; Sainz Sapera, Luis; Mesas García, Juan José

    2011-01-01

    The current number of magnetic and electronic ballast discharge lamps in power distribution systems is increasing because they perform better than incandescent lamps. This paper studies the magnetic discharge lamp modeling. In particular, the arc voltage waveform is analyzed and the limitations of the square waveform model are revealed from experimental measurements.

  3. 76 FR 70547 - Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Science.gov (United States)

    2011-11-14

    ... the term ``fluorescent lamp,'' which EPCA defines as ``a low pressure mercury electric-discharge... discharge into light,'' and as including the four enumerated types of fluorescent lamps for which EPCA... Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts; Final Rule #0;#0;Federal...

  4. BAD-LAMP defines a subset of early endocytic organelles in subpopulations of cortical projection neurons.

    Science.gov (United States)

    David, Alexandre; Tiveron, Marie-Catherine; Defays, Axel; Beclin, Christophe; Camosseto, Voahirana; Gatti, Evelina; Cremer, Harold; Pierre, Philippe

    2007-01-15

    The brain-associated LAMP-like molecule (BAD-LAMP) is a new member of the family of lysosome associated membrane proteins (LAMPs). In contrast to other LAMPs, which show a widespread expression, BAD-LAMP expression in mice is confined to the postnatal brain and therein to neuronal subpopulations in layers II/III and V of the neocortex. Onset of expression strictly parallels cortical synaptogenesis. In cortical neurons, the protein is found in defined clustered vesicles, which accumulate along neurites where it localizes with phosphorylated epitopes of neurofilament H. In primary neurons, BAD-LAMP is endocytosed, but is not found in classical lysosomal/endosomal compartments. Modification of BAD-LAMP by addition of GFP revealed a cryptic lysosomal retention motif, suggesting that the cytoplasmic tail of BAD-LAMP is actively interacting with, or modified by, molecules that promote its sorting away from lysosomes. Analysis of BAD-LAMP endocytosis in transfected HeLa cells provided evidence that the protein recycles to the plasma membrane through a dynamin/AP2-dependent mechanism. Thus, BAD-LAMP is an unconventional LAMP-like molecule and defines a new endocytic compartment in specific subtypes of cortical projection neurons. The striking correlation between the appearance of BAD-LAMP and cortical synatogenesis points towards a physiological role of this vesicular determinant for neuronal function.

  5. Energy Efficiency Comparison between Compact Fluorescent Lamp and Common Light Bulb

    Science.gov (United States)

    Tanushevsk, Atanas; Rendevski, Stojan

    2016-01-01

    For acquainting the students of applied physics and students of teaching physics with the concept of energy efficiency, electrical and spectral characteristics of two widely used lamps--integrated fluorescence lamp and common light bulb have been investigated. Characterization of the lamps has been done by measuring the spectral irradiance and…

  6. Axial segregation in high intensity discharge lamps measured by laser absorption spectroscopy

    NARCIS (Netherlands)

    Flikweert, A.J.; Nimalasuriya, T.; Groothuis, C.H.J.M.; Kroesen, G.M.W.; Stoffels, W.W.

    2005-01-01

    High intensity discharge lamps have a high efficiency. These lamps contain rare-earth additives (in our case dysprosium iodide) which radiate very efficiently. A problem is color separation in the lamp because of axial segregation of the rare-earth additives, caused by diffusion and convection. Here

  7. 77 FR 21038 - Energy Conservation Program: Test Procedures for Light-Emitting Diode Lamps

    Science.gov (United States)

    2012-04-09

    ... available most commonly in the market. If the LED lamp is not rated for 120 volts, DOE proposes that it..., are available in the market. If such lamps are available, DOE requests comment about whether such... lamp to determine the rated lifetime and the final method in Table III.1 test the LED source to...

  8. The effect of operating lamps on the protected area of a unidirectional down flow (UDF) system

    NARCIS (Netherlands)

    Traversari, A.A.L.; Bottenheft, C.; Louman, R.; Heumen, S.P.M. van; Böggeman, J.

    2016-01-01

    Background: Operating lamps are often seen as the most disruptive factors within the protective area in the operating theater (OT). The effect of the operation lamps (with different shapes) should be demonstrated in an OT by trial, since research on the effects of the lamps is still limited.

  9. 30 CFR 75.518-2 - Incandescent lamps, overload and short circuit protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Incandescent lamps, overload and short circuit...-General § 75.518-2 Incandescent lamps, overload and short circuit protection. Incandescent lamps installed... or direct current feeder circuits, need not be provided with separate short circuit or overload...

  10. Transport phenomena in metal-halide lamps : a poly-diagnostic study

    NARCIS (Netherlands)

    Nimalasuriya, T.

    2007-01-01

    Worldwide about 20% of all electricity is used for lighting. It is therefore of great interest to develop a lamp that has high e±cacy, good colour rendering and long lifetime. The metal-halide lamp is a gas discharge lamp that meets all these demands. Unfortunately there are still issues with this

  11. 21 CFR 1040.30 - High-intensity mercury vapor discharge lamps.

    Science.gov (United States)

    2010-04-01

    ... use. (4) Outer envelope means the lamp element, usually glass, surrounding a high-pressure arc... than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will... unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish...

  12. Antibiotic resistance monitoring: the Spanish programme. The VAV Network. Red de Vigilancia de Resistencias Antibióticas en Bacterias de Origen Veterinario.

    Science.gov (United States)

    Moreno, M A; Domínguez, L; Teshager, T; Herrero, I A; Porrero, M C

    2000-05-01

    Antimicrobial resistance is a problem in modern public health and antimicrobial use and especially misuse, the most important selecting force for bacterial antibiotic resistance. As this resistance must be monitored we have designed the Spanish network 'Red de Vigilancia de Resistencias Antibióticas en Bacterias de Origen Veterinario'. This network covers the three critical points of veterinary responsibility, bacteria from sick animals, bacteria from healthy animals and bacteria from food animals. Key bacteria, antimicrobials and animal species have been defined for each of these groups along with laboratory methods for testing antimicrobial susceptibility and for data analysis and reporting. Surveillance of sick animals was first implemented using Escherichia coli as the sentinel bacterium. Surveillance of E. coli and Enterococcus faecium from healthy pigs was implemented in 1998. In July 1999, data collection on Salmonella spp. was initiated in poultry slaughterhouses. Additionally, the prevalence of vancomycin resistant E. faecium was also monitored. This network has specific topics of interest related to methods of determining resistance, analysis and reporting of data, methods of use for veterinary practitioners and collaboration with public health authorities.

  13. Lot quality assurance sampling for monitoring coverage and quality of a targeted condom social marketing programme in traditional and non-traditional outlets in India.

    Science.gov (United States)

    Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal

    2010-02-01

    This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.

  14. Automatic Lamp and Fan Control Based on Microcontroller

    Science.gov (United States)

    Widyaningrum, V. T.; Pramudita, Y. D.

    2018-01-01

    In general, automation can be described as a process following pre-determined sequential steps with a little or without any human exertion. Automation is provided with the use of various sensors suitable to observe the production processes, actuators and different techniques and devices. In this research, the automation system developed is an automatic lamp and an automatic fan on the smart home. Both of these systems will be processed using an Arduino Mega 2560 microcontroller. A microcontroller is used to obtain values of physical conditions through sensors connected to it. In the automatic lamp system required sensors to detect the light of the LDR (Light Dependent Resistor) sensor. While the automatic fan system required sensors to detect the temperature of the DHT11 sensor. In tests that have been done lamps and fans can work properly. The lamp can turn on automatically when the light begins to darken, and the lamp can also turn off automatically when the light begins to bright again. In addition, it can concluded also that the readings of LDR sensors are placed outside the room is different from the readings of LDR sensors placed in the room. This is because the light intensity received by the existing LDR sensor in the room is blocked by the wall of the house or by other objects. Then for the fan, it can also turn on automatically when the temperature is greater than 25°C, and the fan speed can also be adjusted. The fan may also turn off automatically when the temperature is less than equal to 25°C.

  15. First international collaborative study to evaluate rabies antibody detection method for use in monitoring the effectiveness of oral vaccination programmes in fox and raccoon dog in Europe

    DEFF Research Database (Denmark)

    Wasniewski, M; Almeida, I; Baur, A

    2016-01-01

    The most effective and sustainable method to control and eliminate rabies in wildlife is the oral rabies vaccination (ORV) of target species, namely foxes and raccoon dogs in Europe. According to WHO and OIE, the effectiveness of oral vaccination campaigns should be regularly assessed via disease...... surveillance and ORV antibody monitoring. Rabies antibodies are generally screened for in field animal cadavers, whose body fluids are often of poor quality. Therefore, the use of alternative methods such as the enzyme-linked immunosorbent assay (ELISA) has been proposed to improve reliability of serological...... results obtained on wildlife samples. We undertook an international collaborative study to determine if the commercial BioPro ELISA Rabies Ab kit is a reliable and reproducible tool for rabies serological testing. Our results reveal that the overall specificity evaluated on naive samples reached 96...

  16. New guidelines are needed to manage heat stress in elite sports--The Fédération Internationale de Volleyball (FIVB) Heat Stress Monitoring Programme.

    Science.gov (United States)

    Bahr, Roald; Reeser, Jonathan C

    2012-09-01

    There seems to be a discrepancy between the available heat stress guidelines and the actual risk of heat-related illness among professional beach volleyball players competing under hot and humid conditions. To monitor heat stress and record cases of heat-related medical forfeits on the Swatch FIVB Beach Volleyball World Tour. The FIVB Heat Stress Monitoring Protocol covered events on the FIVB Beach Volleyball World Tour and FIVB Beach Volleyball World Championships during the 2009, 2010 and 2011 seasons (51 events, most of these double gender). The protocol consisted of (1) measuring the Wet Bulb Globe Temperature (WBGT) on centre court prior to the start of every match, and (2) recording any heat-related medical forfeits during the tournament. Data were collected during 48 of 51 events. There were nine events where the peak WBGT exceeded the US Navy Black flag conditions of >32.3°C and an additional two events where the peak WBGT exceeded 31°C, (meeting Red flag conditions.) In two events, the average WBGT equalled at least 31°C. One case of a medical forfeit related to heat stress was recorded over the 3-year surveillance period: an athlete whose fluid balance was compromised from a 3-day bout of acute gastroenteritis. The incidence of significant heat illness among athletes competing on the FIVB Beach Volleyball World Tour appears to be quite low, even though weather conditions frequently result in a WBGT index >32°C. Currently available guidelines appear to be inadequate to fully assess the risk of heat stress and too conservative to inform safety decisions in professional beach volleyball.

  17. Evaluation and monitoring of Research and Development projects and programmes: Experience of the task force on the evaluation of TAFTIE; La valutazione e il monitoraggio dei progetti e dei programmi di R&S: esperienza della Task Force sulla valutazione di TAFTIE

    Energy Technology Data Exchange (ETDEWEB)

    Scarpitti, L [ENEA, Rome (Italy). Funzione Centrale Studi

    1996-08-01

    This paper allows to compare the experiences in the evaluation and monitoring fields among 8 different European agencies (ENEA, Italian National Agency for New Technologies, Energy and the Environment, included) directly involved in technology transfer projects and programmes. In order to compare the different experiences three levels of analysis are used: evaluation methodologies, performance indicators, project characterisation and databases.

  18. Color Degradation of Textiles with Natural Dyes and of Blue Scale Standards Exposed to White LED Lamps:Evaluation of White LED Lamps for Effectiveness as Museum Lighting

    Science.gov (United States)

    Ishii, Mie; Moriyama, Takayoshi; Toda, Masahiro; Kohmoto, Kohtaro; Saito, Masako

    White light-emitting diodes (LED) are well suited for museum lighting because they emit neither UV nor IR radiation, which damage artifacts. The color degradation of natural dyes and blue scale standards (JIS L 0841) by white LED lamps are examined, and the performance of white LED lamps for museum lighting is evaluated. Blue scale standard grades 1-6 and silk fabrics dyed with 22 types of natural dyes classified as mid to highly responsive in a CIE technical report (CIE157:2004) were exposed to five types of white LED lamps using different luminescence methods and color temperatures. Color changes were measured at each 15000 lx·hr (500 lx at fabric surface × 300 hr) interval ten times. The accumulated exposure totaled 150000 lx·hr. The data on conventional white LED lamps and previously reported white fluorescent (W) and museum fluorescent (NU) lamps was evaluated. All the white LED lamps showed lower fading rates compared with a W lamp on a blue scale grade 1. The fading rate of natural dyes in total was the same between an NU lamp (3000 K) and a white LED lamp (2869 K). However, yellow natural dyes showed higher fading rates with the white LED lamp. This tendency is due to the high power characteristic of the LED lamp around 400-500 nm, which possibly contributes to the photo-fading action on the dyes. The most faded yellow dyes were Ukon (Curcuma longa L.) and Kihada (Phellodendron amurense Rupr.), and these are frequently used in historic artifacts such as kimono, wood-block prints, and scrolls. From a conservation point of view, we need to continue research on white LED lamps for use in museum lighting.

  19. CALiPER Retail Lamps Study 3.2: Lumen and Chromaticity Maintenance of LED A Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-31

    This CALiPER report examines lumen depreciation and color shift of 17 different A lamps in steady-state conditions (15 LED, 1 CFL, 1 halogen). The goal of this investigation was to examine the long-term performance of complete LED lamps relative to benchmark halogen and CFL lamps—in this case, A lamps emitting approximately 800 lumens operated continuously at a relatively high ambient temperature of 45°C.

  20. Energy Management Programmes for Industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-05

    The IEA Policy Pathway publications provide details on how to implement specific recommendations drawn from the IEA 25 Energy Efficiency Policy Recommendations. This Policy Pathway, jointly produced by the International Energy Agency and the Institute for Industrial Productivity, develops the critical steps for policy makers implementing energy management programmes for industry. Optimising energy use in industry is essential to improve industrial competitiveness and achieve wider societal goals such as energy security, economic recovery and development, climate change mitigation and environmental protection. While there is significant potential to decrease energy consumption in this sector, opportunities to improve energy efficiency are still under-exploited. Energy management programmes have shown to be instrumental in addressing many of the barriers that inhibit wide-scale uptake of energy management in industry. The Policy Pathway builds on lessons learned from country experiences and provides actionable guidance on how to plan and design, implement, evaluate and monitor energy management programmes for industry.

  1. Loop-mediated isothermal amplification (LAMP) assays for the species-specific detection of Eimeria that infect chickens.

    Science.gov (United States)

    Barkway, Christopher P; Pocock, Rebecca L; Vrba, Vladimir; Blake, Damer P

    2015-02-20

    Eimeria species parasites, protozoa which cause the enteric disease coccidiosis, pose a serious threat to the production and welfare of chickens. In the absence of effective control clinical coccidiosis can be devastating. Resistance to the chemoprophylactics frequently used to control Eimeria is common and sub-clinical infection is widespread, influencing feed conversion ratios and susceptibility to other pathogens such as Clostridium perfringens. Despite the availability of polymerase chain reaction (PCR)-based tools, diagnosis of Eimeria infection still relies almost entirely on traditional approaches such as lesion scoring and oocyst morphology, but neither is straightforward. Limitations of the existing molecular tools include the requirement for specialist equipment and difficulties accessing DNA as template. In response a simple field DNA preparation protocol and a panel of species-specific loop-mediated isothermal amplification (LAMP) assays have been developed for the seven Eimeria recognised to infect the chicken. We now provide a detailed protocol describing the preparation of genomic DNA from intestinal tissue collected post-mortem, followed by setup and readout of the LAMP assays. Eimeria species-specific LAMP can be used to monitor parasite occurrence, assessing the efficacy of a farm's anticoccidial strategy, and to diagnose sub-clinical infection or clinical disease with particular value when expert surveillance is unavailable.

  2. Characterizing risk factors for pediatric lamp oil product exposures.

    Science.gov (United States)

    Sheikh, S; Chang, A; Kieszak, S; Law, R; Bennett, H K W; Ernst, E; Bond, G R; Spiller, H A; Schurz-Rogers, H; Chu, A; Bronstein, A C; Schier, J G

    2013-11-01

    Poisonings from lamp oil ingestion continue to occur worldwide among the pediatric population despite preventive measures such as restricted sale of colored and scented lamp oils. This suggests that optimal prevention practices for unintentional pediatric exposures to lamp oil have yet to be identified and/or properly implemented. To characterize demographic, health data, and potential risk factors associated with reported exposures to lamp oil by callers to poison centers (PCs) in the US and discuss their public health implications. This was a two part study in which the first part included characterizing all exposures to a lamp oil product reported to the National Poison Data System (NPDS) with regard to demographics, exposure, health, and outcome data from 1/1/2000 to 12/31/2010. Regional penetrance was calculated using NPDS data by grouping states into four regions and dividing the number of exposure calls by pediatric population per region (from the 2000 US census). Temporal analyses were performed on NPDS data by comparing number of exposures by season and around the July 4th holiday. Poisson regression was used to model the count of exposures for these analyses. In the second part of this project, in order to identify risk factors we conducted a telephone-based survey to the parents of children from five PCs in five different states. The 10 most recent lamp oil product exposure calls for each poison center were systematically selected for inclusion. Calls in which a parent or guardian witnessed a pediatric lamp oil product ingestion were eligible for inclusion. Data on demographics, exposure information, behavioral traits, and health were collected. A descriptive analysis was performed and Fisher's exact test was used to evaluate associations between variables. All analyses were conducted using SAS v9.3. Among NPDS data, 2 years was the most common patient age reported and states in the Midwestern region had the highest numbers of exposure calls compared to

  3. Ozone measurements 2010. [EMEP Co-operative Programme for Monitoring and Evaluation of the Long-range Transmission of Air Pollutants in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Hjellbrekke, Anne-Gunn; Solberg, Sverre; Fjaeraa, Ann Mari

    2012-07-01

    From the Introduction: Ozone is a natural constituent of the atmosphere and plays a vital role in many atmospheric processes. However, man-made emissions of volatile organic compounds and nitrogen oxides have increased the photochemical formation of ozone in the troposphere. Until the end of the 1960s the problem was basically believed to be one of the big cities and their immediate surroundings. In the 1970s, however, it was found that the problem of photochemical oxidant formation is much more widespread. The ongoing monitoring of ozone at rural sites throughout Europe shows that episodes of high concentrations of ground-level ozone occur over most parts of the continent every summer. During these episodes the ozone concentrations can reach values above ambient air quality standards over large regions and lead to adverse effects for human health and vegetation. Historical records of ozone measurements in Europe and North America indicate that in the last part of the nineteenth century the values were only about half of the average surface ozone concentrations measured in the same regions during the last 10-15 years (Bojkov, 1986; Volz and Kley, 1988).The formation of ozone is due to a large number of photochemical reactions taking place in the atmosphere and depends on the temperature, humidity and solar radiation as well as the primary emissions of nitrogen oxides and volatile organic compounds. Together with the non-linear relationships between the primary emissions and the ozone formation, these effects complicates the abatement strategies for ground-level ozone and makes photochemical models crucial in addition to the monitoring data. The 1999 Gothenburg Protocol is designed for a joint abatement of acidification, eutrophication and ground-level ozone. It has been estimated that once the Protocol is implemented, the number of days with excessive ozone levels will be halved and that the exposure of vegetation to excessive ozone levels will be 44% down on 1990

  4. A comparison of the use, effectiveness and safety of bezafibrate, gemfibrozil and simvastatin in normal clinical practice using the New Zealand Intensive Medicines Monitoring Programme (IMMP)

    Science.gov (United States)

    Beggs, Peter W; Clark, David WJ; Williams, Sheila M; Coulter, David M

    1999-01-01

    Aims Because of the importance of treating dyslipidaemia in the prevention of ischaemic heart disease and because patient selection criteria and outcomes in clinical trials do not necessarily reflect what happens in normal clinical practice, we compared outcomes from bezafibrate, gemfibrozil and simvastatin therapy under conditions of normal use. Methods A random sample of 200 patients was selected from the New Zealand Intensive Medicines Monitoring Programme’s (IMMP) patient cohorts for each drug. Questionnaires sent to prescribers requested information on indications, risk factors for ischaemic heart disease, lipid profiles with changes during treatment and reasons for stopping therapy. Results 80% of prescribers replied and 83% of these contained useful information. The three groups were similar for age, sex and geographical region, but significantly more patients on bezafibrate had diabetes and/or hypertension than those on gemfibrozil or simvastatin. After treatment and taking the initial measure into account, the changes in serum lipid values were consistent with those generally observed, but with gemfibrozil being significantly less effective than expected. More patients (15.8%) stopped gemfibrozil because of an inadequate response compared with bezafibrate (5.4%) and simvastatin (1.6%). Gemfibrozil treatment was also withdrawn significantly more frequently due to a possible adverse reaction compared with the other two drugs. Conclusions In normal clinical practice in New Zealand gemfibrozil appears less effective and more frequently causes adverse effects leading to withdrawal of treatment than either bezafibrate or simvastatin. PMID:10073746

  5. Programmable electronic safety systems

    International Nuclear Information System (INIS)

    Parry, R.R.

    1993-01-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement fail-safe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  6. Programmable Electronic Safety Systems

    International Nuclear Information System (INIS)

    Parry, R.

    1993-05-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement failsafe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  7. National programme: Finland

    International Nuclear Information System (INIS)

    Forsten, J.

    1986-01-01

    Finland's programmes in the field of reactor pressure components are presented in this paper. The following information on each of these programmes is given: the brief description of the programme; the programme's schedule and duration; the name of the project manager

  8. Monitoring of insects with public participation (MIPP; EU LIFE project 11 NAT/IT/000252: overview on a citizen science initiative and a monitoring programme (Insecta: Coleoptera; Lepidoptera; Orthoptera

    Directory of Open Access Journals (Sweden)

    Franco Mason

    2015-06-01

    Full Text Available The LIFE project “MIPP” - Monitoring of Insects with Public Participation (11 NAT/IT/000252 is focused on selected insect species (five Coleoptera, three Lepidoptera, one Orthoptera, all included in the annexes II and IV of the Habitats Directive (HD 92/43/EEC. One important aim is a citizen science initiative where every person may become a citizen scientist and collect faunistic data on the above species throughout Italy. Another objective of the project MIPP is the development of standard methods for monitoring the conserva- tion status of the five target beetle species. One innovative method employed is a sniffer-dog (“Osmodog”, trained to find the rare and endangered hermit beetle, Osmoderma eremita, which lives in veteran, hollow trees. The dog detects the strong smell of mature peach produced by adult males and an odor produced by the larvae. Another objective of the project MIPP is the dissemination of topics such as HD, Natura 2000, importance of dead-wood, Life projects, insect monitoring and conservation.

  9. Electrical Versus Optical: Comparing Methods for Detecting Terahertz Radiation Using Neon Lamps

    Science.gov (United States)

    Slocombe, L. L.; Lewis, R. A.

    2018-05-01

    Terahertz radiation impinging on a lit neon tube causes additional ionization of the encapsulated gas. As a result, the electrical current flowing between the electrodes increases and the glow discharge in the tube brightens. These dual phenomena suggest two distinct modes of terahertz sensing. The electrical mode simply involves measuring the electrical current. The optical mode involves monitoring the brightness of the weakly ionized plasma glow discharge. Here, we directly compare the two detection modes under identical experimental conditions. We measure 0.1-THz radiation modulated at frequencies in the range 0.1-10 kHz, for lamp currents in the range 1-10 mA. We find that electrical detection provides a superior signal-to-noise ratio while optical detection has a faster response. Either method serves as the basis of a compact, robust, and inexpensive room-temperature detector of terahertz radiation.

  10. Assessing temporal trends and source regions of per- and polyfluoroalkyl substances (PFASs) in air under the Arctic Monitoring and Assessment Programme (AMAP)

    Science.gov (United States)

    Wong, Fiona; Shoeib, Mahiba; Katsoyiannis, Athanasios; Eckhardt, Sabine; Stohl, Andreas; Bohlin-Nizzetto, Pernilla; Li, Henrik; Fellin, Phil; Su, Yushan; Hung, Hayley

    2018-01-01

    Long-term Arctic air monitoring of per- and polyfluoroalkyl substances (PFASs) is essential in assessing their long-range transport and for evaluating the effectiveness of chemical control initiatives. We report for the first time temporal trends of neutral and ionic PFASs in air from three arctic stations: Alert (Canada, 2006-2014); Zeppelin (Svalbard, Norway, 2006-2014) and Andøya (Norway, 2010-2014). The most abundant PFASs were the perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), perfluorobutanoic acid (PFBA), and fluorotelomer alcohols (FTOHs). All of these chemicals exhibited increasing trends at Alert with doubling times (t2) of 3.7 years (y) for PFOA, 2.9 y for PFOS, 2.5 y for PFBA, 5.0 y for 8:2 FTOH and 7.0 y for 10:2 FTOH. In contrast, declining or non-changing trends, were observed for PFOA and PFOS at Zeppelin (PFOA, half-life, t1/2 = 7.2 y; PFOS t1/2 = 67 y), and Andøya (PFOA t1/2 = 1.9 y; PFOS t1/2 = 11 y). The differences in air concentrations and in time trends between the three sites may reflect the differences in regional regulations and source regions. We investigate the source region for particle associated compounds using the Lagrangian particle dispersion model FLEXPART. Model results showed that PFOA and PFOS are impacted by air masses originating from the ocean or land. For instance, PFOA at Alert and PFOS at Zeppelin were dominated by oceanic air masses whereas, PFOS at Alert and PFOA at Zeppelin were influenced by air masses transported from land.

  11. Strengthening health systems capacity to monitor and evaluate programmes targeted at reducing abortion-related maternal mortality in Jessore district, Bangladesh.

    Science.gov (United States)

    Huda, Fauzia Akhter; Ahmed, Anisuddin; Ford, Evelyn Rebecca; Johnston, Heidi Bart

    2015-09-28

    Abortion related deaths as a proportion of maternal mortality appears to have fallen dramatically in Bangladesh from 5 % in 2001 to 1 % in 2010. Yet complications from menstrual regulation (MR) and unsafe abortion continue to cause deleterious health, economic and social consequences for women in the country. This quasi experimental design study with a baseline (January to December 2008) and an endline survey (August to October 2009) was conducted in 69 public, private, and NGO sector health facilities in Jessore district of Bangladesh with the objective of adapting and implementing a set of process indicators, specifically to supplement the indicators for monitoring emergency obstetric care interventions. At the baseline, we collected retrospective data from all 69 health facilities that provided MR, legal abortion or post-abortion care (PAC), by reviewing their last one year's records. Three months after introducing the safe menstrual regulation and abortion care (SMRAC) model, endline data was collected. Signal function (critical services that facilities must perform in order to prevent and treat abortion complications) analysis was used to characterize facilities as providing basic care, comprehensive care, or neither. Facility mapping, and records on services provided and complications treated were used to further characterize service availability and to describe service use and quality. No facilities fulfilled criteria for 'comprehensive' care at either the baseline or end line while only one met the 'basic' criteria during the endline of the project. Recommended uterine evacuation technology, manual vacuum aspiration (MVA) was used for 100.0 % of MR clients but only for 8.0 % or fewer PAC patients. MR clients were 37.5 times more likely than PAC patients to leave facilities with a contraceptive method (75.0 % vs. 2.0 %). Persistent use of older uterine evacuation technologies was observed when recommended techniques were widely available in the facilities

  12. Factors affecting {sup 210}Po and {sup 210}Pb activity concentrations in mussels and implications for environmental bio-monitoring programmes

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fernando P., E-mail: carvalho@itn.p [Nuclear and Technological Institute (ITN), Department of Radiological Protection and Nuclear Safety, E.N. 10, 2686-953 Sacavem (Portugal); Oliveira, Joao M.; Alberto, G. [Nuclear and Technological Institute (ITN), Department of Radiological Protection and Nuclear Safety, E.N. 10, 2686-953 Sacavem (Portugal)

    2011-02-15

    The activity of {sup 210}Po and {sup 210}Pb was determined in mussels of the same size (3.5-4.0 cm shell length) sampled monthly over a 17-month period at the Atlantic coast of Portugal. Average radionuclide concentration values in mussels were 759 {+-} 277 Bq kg{sup -1} for {sup 210}Po (range 460-1470 Bq kg{sup -1} dry weight), and 45 {+-} 19 Bq kg{sup -1} for {sup 210}Pb (range 23-96 Bq kg{sup -1} dry weight). Environmental parameters and mussel biometric parameters were monitored during the same period. Although there was no seasonal variation of radionuclide concentrations in sea water during the study period, the concentration of radionuclide activity in mussels varied seasonally displaying peaks of high concentrations in winter and low concentrations in summer. Analysis of radionuclide data in relation to the physiological Condition Index of mussels revealed that {sup 210}Po and {sup 210}Pb activities in the mussel (average activity per individual) remained nearly constant during the investigation period, while mussel body weight fluctuated due to fat storage/expenditure in the soft tissues. Similar variation of radionuclide concentrations was observed in mussels transplanted from the sea coast into the Tejo Estuary. However, under estuarine environmental conditions and with higher food availability throughout the year, transplanted mussel Condition Index was higher than in coastal mussels and average radionuclide concentrations were 210 {+-} 75 Bq kg{sup -1} (dry weight) for {sup 210}Po and 10 {+-} 4 Bq kg{sup -1} (dry weight) for {sup 210}Pb, therefore lower than in coastal mussels with similar shell length. It is concluded that the apparent seasonal fluctuation and inter-site difference of radionuclide concentrations were mostly caused by mussel body weight fluctuation and not by radionuclide body burden fluctuation. This interpretation can be extended to the apparent seasonal fluctuation in concentrations of lipophilic and lipophobic contaminants in

  13. Metal halide arc discharge lamp having short arc length

    Science.gov (United States)

    Muzeroll, Martin E. (Inventor)

    1994-01-01

    A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

  14. Retroactive effects of energy-saving lamps; Netzrueckwirkungen von Energiesparlampen

    Energy Technology Data Exchange (ETDEWEB)

    Duerrenberger, G. [Forschungsstiftung Mobilkommunikation c/o ETH Zuerich (Switzerland); Klaus, G. [Maxwave AG, Zuerich (Switzerland)

    2009-11-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at the repercussions on the power supply network that are caused by energy-saving lamps (ESL). These effects result from the operation of the lamps' electronic ballasts which operate at high frequencies. The most noticeable network repercussions that are caused by the rapid current variations in the ESL are discussed, as are ways of considerably reducing them. As for effects on the grid, the authors state that it is not to be expected that any problematic mains feedback will result in practice, particularly not in the well-dimensioned Swiss electricity grid. The methods used in the analysis and the detailed results obtained are presented in tabular and graphical form and discussed.

  15. Cooling analysis of a light emitting diode automotive fog lamp

    Directory of Open Access Journals (Sweden)

    Zadravec Matej

    2017-01-01

    Full Text Available Efficiency of cooling fins inside of a light emitting diode fog lamp is studied using computational fluid dynamics. Diffusion in heat sink, natural convection and radiation are the main principles of the simulated heat transfer. The Navier-Stokes equations were solved by the computational fluid dynamics code, including Monte Carlo radiation model and no additional turbulence model was needed. The numerical simulation is tested using the existing lamp geometry and temperature measurements. The agreement is excellent inside of few degrees at all measured points. The main objective of the article is to determine the cooling effect of various heat sink parts. Based on performed simulations, some heat sink parts are found to be very ineffective. The geometry and heat sink modifications are proposed. While radiation influence is significant, compressible effects are found to be minor.

  16. Environmental friendly high efficient light source plasma lamp - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Courret, G.; Calame, L. [Haute Ecole d' ingenierie et de gestion du canton de Vaud, Institut de micro et nano techniques, Yverdon-les-Bains (Switzerland); Meyer, A. [Solaronix SA, Aubonne (Switzerland)

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at work done on the development of a sulphur-based plasma lamp. In 2007, the capability of a new modulator has been explored. The most important results are discussed. With the production of a 1.2 cm{sup 3} bulb, the way towards the production of a 100 W lamp has been opened. The authors comment that modulation by impulses increases the luminous efficiency in comparison to modulation using a continuous sinusoidal wave. The report deals with the history of the project, the development of the new modulator, the use of rotational effects and the optimisation of the amount of active substances - tellurium and selenium - in the bulb. The electromagnetic coupling system used is described and discussed.

  17. Waste Disposal: The PRACLAY Programme

    Energy Technology Data Exchange (ETDEWEB)

    De Bruyn, D

    2000-07-01

    Principal achievements in 2000 with regard to the PRACLAY programme are presented. The PRACLAY project has been conceived: (1) to demonstrate the construction and the operation of a gallery for the disposal of HLW in a clay formation; (2) to improve knowledge on deep excavations in clay through modelling and monitoring; (3) to design, install and operate a complementary mock-up test (OPHELIE) on the surface. In 1999, efforts were focussed on the operation of the OPHELIE mock-up and the CLIPEX project to monitor the evolution of hydro-mechanical parameters of the Boom Clay Formation near the face of a gallery during excavation.

  18. Waste Disposal: The PRACLAY Programme

    International Nuclear Information System (INIS)

    De Bruyn, D.

    2000-01-01

    Principal achievements in 2000 with regard to the PRACLAY programme are presented. The PRACLAY project has been conceived: (1) to demonstrate the construction and the operation of a gallery for the disposal of HLW in a clay formation; (2) to improve knowledge on deep excavations in clay through modelling and monitoring; (3) to design, install and operate a complementary mock-up test (OPHELIE) on the surface. In 1999, efforts were focussed on the operation of the OPHELIE mock-up and the CLIPEX project to monitor the evolution of hydro-mechanical parameters of the Boom Clay Formation near the face of a gallery during excavation

  19. Flash lamp annealing of ion implanted boron profiles

    International Nuclear Information System (INIS)

    Wieser, E.; Syhre, H.; Ruedenauer, F.G.; Steiger, W.

    1983-05-01

    The diffusion behaviour of ion implanted boron profiles (5x10E15 B/cm 2 , 50keV) in silicon at 800 0 C and 900 0 C has been compared for samples with and without foregoing flahs - lamp annealing of the radiation damage. The observed differences are discussed with respect to mechanisms of diffusion inhibition in the high concentration region. (Author) [de

  20. Photometric characterization of LED's for optimal design of interior lamps

    International Nuclear Information System (INIS)

    Hernandez, O.; Guerra, H.; Leon, V.; Torres, A. W.; Castannon, H.; Camas, J.

    2012-01-01

    The Tuxtla Gutierrez Technology Institute, and the Innovaluz of Mexico S A of C V company have joined forces to develop LED lighting technology in Chiapas, Mexico. We performed a comprehensive study of power savings for a household using this luminary. The main results of the Lighting are presented exclusively for the ILIGPL153BF24W model, as well as the design features of a functional lamp. (Author)

  1. Numerical Analysis of Thermo Hydraulic Conditions in Car Fog Lamp

    Science.gov (United States)

    Ramšak, M.; Žunič, Z.; Škerget, L.; Jurejevčič, T.

    2009-08-01

    In the article a coupled heat transfer in the solid and fluid inside of a car fog lamp is presented using CFD software CFX [1]. All three basic principles of heat transfer are dealt with: conduction, convection and radiation. Two different approaches to radiation modeling are compared. Laminar and turbulent flow modeling are compared since computed Rayleight number indicates transitional flow regime. Results are in good agreement with the measurements.

  2. Occupational exposure in the fluorescent lamp recycling sector in France

    International Nuclear Information System (INIS)

    Zimmermann, François; Lecler, Marie-Thérèse; Clerc, Frédéric; Chollot, Alain; Silvente, Eric; Grosjean, Jérome

    2014-01-01

    Highlights: • Chemical risks were assessed in the five fluorescent lamp recycling facilities. • The main hazardous agents are mercury vapors and dust containing lead and yttrium. • Exposure and pollutant levels were correlated with steps and processes. • All the stages and processes are concerned by worrying levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m 3 , 15.4 μg/m 3 , 14.0 μg/m 3 , 247.6 μg/m 3 , respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1 mg/m 3 , 9.0 μg/m 3 , 9.0 μg/m 3 , 219.2 μg/m 3 , respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees’ skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures

  3. Occupational exposure in the fluorescent lamp recycling sector in France

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, François, E-mail: francois.zimmermann@inrs.fr; Lecler, Marie-Thérèse; Clerc, Frédéric; Chollot, Alain; Silvente, Eric; Grosjean, Jérome

    2014-07-15

    Highlights: • Chemical risks were assessed in the five fluorescent lamp recycling facilities. • The main hazardous agents are mercury vapors and dust containing lead and yttrium. • Exposure and pollutant levels were correlated with steps and processes. • All the stages and processes are concerned by worrying levels of pollutants. • We suggest recommendations to reduce chemical risk. - Abstract: The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m{sup 3}, 15.4 μg/m{sup 3}, 14.0 μg/m{sup 3}, 247.6 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1 mg/m{sup 3}, 9.0 μg/m{sup 3}, 9.0 μg/m{sup 3}, 219.2 μg/m{sup 3}, respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees’ skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures.

  4. LAM Pilot Study with Imatinib Mesylate (LAMP-1)

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-14-1-0132 TITLE: LAM Pilot Study with Imatinib Mesylate (LAMP-1) PRINCIPAL INVESTIGATOR: Charlie Strange, MD...regarding imatinib mesylate (imatinib) in the treatment of Lymphangioleiomyomatosis ( LAM ) sufficient to power and design a phase 3 imatinib vs. placebo...clinical trial. The hypothesis is that imatinib will be equivalent to rapamycin in short term efficacy and safety. Currently, most LAM patients are

  5. A reassessment of the suspended sediment load in the Madeira River basin from the Andes of Peru and Bolivia to the Amazon River in Brazil, based on 10 years of data from the HYBAM monitoring programme

    Science.gov (United States)

    Vauchel, Philippe; Santini, William; Guyot, Jean Loup; Moquet, Jean Sébastien; Martinez, Jean Michel; Espinoza, Jhan Carlo; Baby, Patrice; Fuertes, Oscar; Noriega, Luis; Puita, Oscar; Sondag, Francis; Fraizy, Pascal; Armijos, Elisa; Cochonneau, Gérard; Timouk, Franck; de Oliveira, Eurides; Filizola, Naziano; Molina, Jorge; Ronchail, Josyane

    2017-10-01

    The Madeira River is the second largest tributary of the Amazon River. It contributes approximately 13% of the Amazon River flow and it may contribute up to 50% of its sediment discharge to the Atlantic Ocean. Until now, the suspended sediment load of the Madeira River was not well known and was estimated in a broad range from 240 to 715 Mt yr-1. Since 2002, the HYBAM international network developed a new monitoring programme specially designed to provide more reliable data than in previous intents. It is based on the continuous monitoring of a set of 11 gauging stations in the Madeira River watershed from the Andes piedmont to the confluence with the Amazon River, and discrete sampling of the suspended sediment concentration every 7 or 10 days. This paper presents the results of the suspended sediment data obtained in the Madeira drainage basin during 2002-2011. The Madeira River suspended sediment load is estimated at 430 Mt yr-1 near its confluence with the Amazon River. The average production of the Madeira River Andean catchment is estimated at 640 Mt yr-1 (±30%), the corresponding sediment yield for the Andes is estimated at 3000 t km-2 yr-1 (±30%), and the average denudation rate is estimated at 1.20 mm yr-1 (±30%). Contrary to previous results that had mentioned high sedimentation rates in the Beni River floodplain, we detected no measurable sedimentation process in this part of the basin. On the Mamoré River basin, we observed heavy sediment deposition of approximately 210 Mt yr-1 that seem to confirm previous studies. But while these studies mentioned heavy sedimentation in the floodplain, we showed that sediment deposition occurred mainly in the Andean piedmont and immediate foreland in rivers (Parapeti, Grande, Pirai, Yapacani, Chimoré, Chaparé, Secure, Maniqui) with discharges that are not sufficiently large to transport their sediment load downstream in the lowlands.

  6. Simulation of pulsed dielectric barrier discharge xenon excimer lamp

    International Nuclear Information System (INIS)

    Bogdanov, E A; Kudryavtsev, A A; Arslanbekov, R R; Kolobov, V I

    2004-01-01

    Recently, it has been shown that the efficiency of excimer lamps can be drastically increased in a pulsed regime. A one-dimensional simulation of pulsed excimer lamps has been performed by Carman and Mildren (2003 J. Phys. D: Appl. Phys. 36 19) (C and M). However, some computational results of the work of C and M are questionable and need to be revisited. In this paper, a dielectric barrier discharge (DBD) in xenon has been simulated for operating conditions similar to those of C and M to better understand plasma dynamics in a pulsed regime. Our simulation results differ considerably from the computational results of C and M. Although these differences do not affect profoundly the plasma macro parameters measured in the C and M experiments, they offer a better understanding of plasma dynamics in pulsed DBDs and form a solid foundation for computational optimization of excimer lamps. It was found that the dynamics of breakdown and the current pulse depend significantly on the initial densities of species after a previous pulse, and so it is important to accurately simulate the plasma evolution in both the afterglow and active stages. It seems possible to modify the power deposition in the plasma by varying external discharge parameters such as the amplitude and the rise time of the applied voltage, and to modify the plasma composition by changing the pulse repetition rate and plasma decay in the afterglow stage

  7. Phototoxic effects of commercial photographic flash lamp on rat eyes.

    Science.gov (United States)

    Inoue, Makoto; Shinoda, Kei; Ohde, Hisao; Tezuka, Keiji; Hida, Tetsuo

    2006-11-01

    To determine whether exposure of the cornea and retina of rats to flashes from a commercial photographic flash lamp is phototoxic. Sprague-Dawley rats were exposed to 10, 100, or 1,000 flashes of the OPTICAM 16M photographic flash lamp (Fujikoeki, Japan) placed 0.1, 1, or 3 m from the eyes. Corneal damage was assessed by a fluorescein staining score, and the retinal damage by eletroretinography (ERG) and histology before and 24 h after exposure. Exposure of the eyes to 1,000 flashes at 0.1 m increased the fluorescein staining score significantly (P = 0.009, the Mann-Whitney test). Scanning electron microscopy (SEM) of the cornea showed a detachment of the epithelial cells from the surface after this exposure. The amplitude of the a-wave was decreased significantly by 23.0% (P = 0.026) of the amplitude before the exposure, and the b-wave by 19.7% (P = 0.0478) following 1,000 flashes at 0.1 m but not by the other exposures. TUNEL-positive cells were present in the outer nuclear layer only after the extreme exposure, but no significant decrease in retinal thickness was seen under any condition. The fluorescein staining score and ERGs recovered to control levels within 1 week. Light exposure to a photographic flash lamp does not induce damage to the cornea and retina except when they are exposed to 1,000 flashes at 0.1 m.

  8. User manual for SPLASH (Single Panel Lamp and Shroud Helper).

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Marvin Elwood

    2006-02-01

    The radiant heat test facility develops test sets providing well-characterized thermal environments, often representing fires. Many of the components and procedures have become standardized to such an extent that the development of a specialized design tool to determine optimal configurations for radiant heat experiments was appropriate. SPLASH (Single Panel Lamp and Shroud Helper) is that tool. SPLASH is implemented as a user-friendly, Windows-based program that allows a designer to describe a test setup in terms of parameters such as number of lamps, power, position, and separation distance. This document is a user manual for that software. Any incidental descriptions of theory are only for the purpose of defining the model inputs. The theory for the underlying model is described in SAND2005-2947 (Ref. [1]). SPLASH provides a graphical user interface to define lamp panel and shroud designs parametrically, solves the resulting radiation enclosure problem for up to 2500 surfaces, and provides post-processing to facilitate understanding and documentation of analyzed designs.

  9. Occupational exposure in the fluorescent lamp recycling sector in France.

    Science.gov (United States)

    Zimmermann, François; Lecler, Marie-Thérèse; Clerc, Frédéric; Chollot, Alain; Silvente, Eric; Grosjean, Jérome

    2014-07-01

    The fluorescent lamp recycling sector is growing considerably in Europe due to increasingly strict regulations aimed at inciting the consumption of low energy light bulbs and their end-of-life management. Chemical risks were assessed in fluorescent lamp recycling facilities by field measurement surveys in France, highlighting that occupational exposure and pollutant levels in the working environment were correlated with the main recycling steps and processes. The mean levels of worker exposure are 4.4 mg/m(3), 15.4 μg/m(3), 14.0 μg/m(3), 247.6 μg/m(3), respectively, for total inhalable dust, mercury, lead and yttrium. The mean levels of airborne pollutants are 3.1mg/m(3), 9.0 μg/m(3), 9.0 μg/m(3), 219.2 μg/m(3), respectively, for total inhalable dust, mercury, lead and yttrium. The ranges are very wide. Surface samples from employees' skin and granulometric analysis were also carried out. The overview shows that all the stages and processes involved in lamp recycling are concerned by the risk of hazardous substances penetrating into the bodies of employees, although exposure of the latter varies depending on the processes and tasks they perform. The conclusion of this study strongly recommends the development of a new generation of processes in parallel with more information sharing and regulatory measures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Identification of ochratoxin A producing Aspergillus carbonarius and A. niger clade isolated from grapes using the loop-mediated isothermal amplification (LAMP) reaction.

    Science.gov (United States)

    Storari, M; von Rohr, R; Pertot, I; Gessler, C; Broggini, G A L

    2013-04-01

    To develop two assays based on the loop-mediated isothermal amplification (LAMP) of DNA for the quick and specific identification of Aspergillus carbonarius and ochratoxigenic strains of the Aspergillus niger clade isolated from grapes. Two sets of primers were designed based on the polyketide synthase genes involved or putatively involved in ochratoxin A (OTA) biosynthesis in A. carbonarius and A. niger clade. Hydroxynaphthol blue was used as indirect method to indicate DNA amplification. The limit of detection of both assays was comparable to that of a PCR reaction. Specificities of the reactions were tested using DNA from different black aspergilli isolated from grapes. The two LAMP assays were then used to identify A. carbonarius and ochratoxigenic A. niger and A. awamori grown in pure cultures without a prior DNA extraction. The two LAMP assays permitted to quickly and specifically identify DNA from OTA-producing black aspergilli, as well as isolates grown in pure culture. Monitoring vineyards for the presence of OTA-producing strains is part of the measures to minimize the occurrence of OTA in grape products. The two LAMP assays developed here could be potentially used to speed the screening process of vineyards for the presence of OTA-producing black aspergilli. © 2013 The Society for Applied Microbiology.

  11. Detection of Cucurbit chlorotic yellows virus from Bemisia tabaci captured on sticky traps using reverse transcription loop-mediated isothermal amplification (RT-LAMP) and simple template preparation.

    Science.gov (United States)

    Okuda, Mitsuru; Okuda, Shiori; Iwai, Hisashi

    2015-09-01

    Cucurbit chlorotic yellows virus (CCYV) of the genus Crinivirus within the family Closteroviridae is an emerging infectious agent of cucurbits leading to severe disease and significant economic losses. Effective detection and identification methods for this virus are urgently required. In this study, a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed to detect CCYV from its vector Bemisia tabaci. LAMP primer sets to detect CCYV were evaluated for their sensitivity and specificity, and a primer set designed from the HSP70h gene with corresponding loop primers were selected. The RT-LAMP assay was applied to detect CCYV from viruliferous B. tabaci trapped on sticky traps. A simple extraction procedure using RNAsecure™ was developed for template preparation. CCYV was detected in all of the B. tabaci 0, 1, 7 and 14 days after they were trapped. Although the rise of turbidity was delayed in reactions using RNA from B. tabaci trapped for 7 and 14 days compared with those from 0 and 1 day, the DNA amplification was sufficient to detect CCYV in all of the samples. These findings therefore present a simple template preparation method and an effective RT-LAMP assay, which can be easily and rapidly performed to monitor CCYV-viruliferous B. tabaci in the field. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Giardia and Cryptosporidium spp. dissemination during wastewater treatment and comparative detection via immunofluorescence assay (IFA), nested polymerase chain reaction (nested PCR) and loop mediated isothermal amplification (LAMP).

    Science.gov (United States)

    Gallas-Lindemann, Carmen; Sotiriadou, Isaia; Plutzer, Judit; Noack, Michael J; Mahmoudi, Mohammad Reza; Karanis, Panagiotis

    2016-06-01

    Environmental water samples from the Lower Rhine area in Germany were investigated via immunofluorescence assays (IFAs), nested polymerase chain reaction (nested PCR) and loop-mediated isothermal amplification (LAMP) to detect the presence of Giardia spp. (n=185) and Cryptosporidium spp. (n=227). The samples were concentrated through filtration or flocculation, and oocysts were purified via centrifugation through a sucrose density gradient. For all samples, IFA was performed first, followed by DNA extraction for the nested PCR and LAMP assays. Giardia cysts were detected in 105 samples (56.8%) by IFA, 62 samples (33.5%) by nested PCR and 79 samples (42.7%) by LAMP. Cryptosporidium spp. were detected in 69 samples (30.4%) by IFA, 95 samples (41.9%) by nested PCR and 99 samples (43.6%) by LAMP. According to these results, the three detection methods are complementary for monitoring Giardia and Cryptosporidium in environmental waters. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A new LED lamp for the collection of nocturnal Lepidoptera and a spectral comparison of light-trapping lamps

    OpenAIRE

    Brehm, Gunnar

    2017-01-01

    Most nocturnal Lepidoptera can be attracted to artificial light sources, particularly to those that emit a high proportion of ultraviolet radiation. Here, I describe a newly developed LED lamp set for the use in the field that is lightweight, handy, robust, and energy efficient. The emitted electromagnetic spectrum corresponds to the peak sensitivity in most Lepidoptera eye receptors (ultraviolet, blue and green). Power LEDs with peaks at 368 nm (ultraviolet), 450 nm (blue), 530 nm (green), a...

  14. Status of the French GCR programmes

    International Nuclear Information System (INIS)

    Bastien, D.

    1991-01-01

    It is reported that France has had no research and development programmes for high temperature gas-cooled reactors (HTGR) since 1979, when the decision was taken to end these studies for budgetary reasons. However, recognizing the value of HTGR technology, the French specialists have been continually monitoring developments in this field throughout the world and obtaining necessary scientific and technical experience implementing the HTGR decommissioning programme, the schedule and technological aspects of which are described

  15. On electrode erosion in fluorescent lamps during instant start

    Energy Technology Data Exchange (ETDEWEB)

    Hadrath, S.

    2006-09-15

    A fluorescent lamp driven with an 'instant start electronic control gear' starts in a glow mode. In the glow mode, which lasts typically for tens of milliseconds, the cathode fall exceeds hundreds of volts. This causes high energy ion bombardment of the electrode which heats the electrode, and induces a transition from glow to arc mode. In the arc mode the electrode emits thermionically and the cathode fall drops to the 12 - 15 V range. Unfortunately, the high energy ion bombardment during the glow mode leads also to intense sputtering of electrode material, including tungsten as well as emitter. Thus, instant started fluorescent lamps often suffer from early failures due to coil fracture. Therefore, the investigation of tungsten erosion during instant start is necessary and was the main goal of this work. The density of neutral atomic tungsten is determined by laser-induced fluorescence (LIF) and optical emission spectroscopy measurements (OES). Investigations are performed on a low-pressure argon dc discharge and on commercial fluorescent lamps. To include the entire temperature profile along the electrode the diffuse and spot operation modes of the dc lamp are studied experimentally and theoretically. The measured dependencies of the cathode temperature along the coil on the discharge and heating parameters are compared with the calculated results. For the first time the tungsten erosion during instant start of commercial fluorescent lamps was experimentally investigated in this work. The erosion process could be related to sputtering. A reconstruction of the temporal evolution of the absolute tungsten population density of the ground state during the glow mode was presented. The sputtered tungsten density increases immediately with the ignition, reaches a maximum where the discharge contracts at the end of the glow mode, and decreases some milliseconds before the glow-to-arc transition takes place. The maximum tungsten density was observed within a

  16. Determining the climate impact of the German government's Integrated Energy and Climate Programme (IEKP) and proposing a plan to continuously monitor its climate impact. Summary; Ermittlung der Klimaschutzwirkung des Integrierten Energie- und Klimaschutzprogramms der Bundesregierung IEKP und Vorschlag fuer ein Konzept zur kontinuierlichen Ueberpruefung der Klimaschutzwirkung des IEKP. Zusammenfassung

    Energy Technology Data Exchange (ETDEWEB)

    Doll, Claus; Eichhammer, Wolfgang; Fleiter, Tobias [Fraunhofer-Institut fuer System- und Innovationsforschung, Karlsruhe (DE)] (and others)

    2012-02-15

    In August 2007, key elements for an Integrated Energy and Climate Programme (IEKP) were adopted in the so-called Meseberg Decisions. This programme will contribute towards reducing greenhouse gas emissions in Germany by 40 % by the year 2020. The Meseberg Decisions were implemented in two packages, which mainly contain legislative amendments and support measures. On 5 December 2007 the German cabinet presented a comprehensive package of 14 laws and regulations which the German Bundestag passed on 6 June 2008 (IEKP I). This is in addition to the measures already in place such as the KfW programme (building refurbishment programme to reduce CO{sub 2}, the ''special energy efficiency programme for SMEs'' etc.). A second package with further legislative proposals (IEKP II) was made public on 18 June 2008. Thus essential elements of the Meseberg Decisions of 2007 are already being implemented. Moreover, there are other measures of the Meseberg programme which are relevant in an EU or in an international framework. What contribution the climate protection instruments enacted under IEKP will really make to this goal must be evaluated on the basis of the concrete design (and in future the concrete implementation), in order to provide policy-makers with decision-making support when further developing climate protection policy. The Integrated Energy and Climate Programme foresees that every two years the federal government should account for the emission reductions achieved thereby and the impacts of the individual measures (programme monitoring). The present research project was conducted in preparation for this objective. Specifically, the project should meet the following goals: 1. To assess how the Meseberg Decisions of August 2007 have been implemented in specific, effective instruments at national or European level (qualitative evaluation of each instrument and the total package). 2. To create a monitoring plan for comprehensive, regular evaluation

  17. Ghana's nuclear programme

    International Nuclear Information System (INIS)

    Ahafia, Albert K.

    1988-01-01

    The Paper gives the purpose of Ghana's Nuclear Programme and describes some specific research activities and peaceful applications of atomic energy in agriculture, medicine and industry. A discussion of some of the problem facing the programme concludes the Paper. (author)

  18. Urine sample used for detection of toxoplasma gondii infection by loop-mediated isothermal amplification (LAMP).

    Science.gov (United States)

    Hu, Xin; Pan, Chang-Wang; Li, Ya-Fei; Wang, Han; Tan, Feng

    2012-02-01

    In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Toxoplasma gondii DNA in mice infected with T. gondii PRU strain. This LAMP assay was based on the sequence of highly repetitive B1 gene. The detection limit of T. gondii LAMP assay was 1 pg of T. gondii DNA, which was evaluated using 10-fold serially diluted DNA of cultured parasites. The LAMP assay was also highly specific for T. gondii and able to detect T. gondii DNA in urine of mice treated with dexamethasone at 90 day post infection (p.i.), although this assay could not detect the DNA in mice urine 2-6 days p.i. These results demonstrated that LAMP is effective for evaluation of therapy effectiveness for T. gondii infection. The established LAMP assay may represent a useful and practical tool for the routine diagnosis and therapeutic evaluation of human toxoplasmosis.

  19. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  20. Fluorescent lamp recycling initiatives in the United States and a recycling proposal based on extended producer responsibility and product stewardship concepts.

    Science.gov (United States)

    Silveira, Geraldo Tr; Chang, Shoou-Yuh

    2011-06-01

    This paper presents an overview of mercury-containing lamp (MCL) recycling initiatives currently available in the world, especially in the United States. The majority of MCLs contain mercury which is a neurotoxin, a persistent pollutant in the environment, and can bioaccumulate in the food chain. Although there are some recycling options in the United States, collection rates are still at 23% of all potential used MCLs. This shows that citizens are either indifferent to or unaware of the recycling alternatives. On the other hand, MCL recycling seems not to be a cost-effective process and, for this reason, in the United States, take-back programmes are still sponsored only by consumers or municipalities. A few retailers have recently initiated limited take-back alternatives and manufacturers have not yet supported financially any consistent recycling alternative in the country. Considering successful experiences, this paper makes a suggestion for an MCL recycling system based on the concepts of extended producer responsibility and product stewardship. A manufacturer-importer advance recycling fee is proposed to finance the collection and recycling system while a MCL-energy recycling fee supported by the energy sector creates a lamp refund process. 'PRO Lamp', a producer responsibility organization, will manage the entire system through a widespread public-private agreement.

  1. NDA National Graduate Programme 'nucleargraduates'

    International Nuclear Information System (INIS)

    Dawson, Carl

    2010-01-01

    The aim of this paper is to outline the NDA National Graduate Programme (nuclear graduates). The NDA has a remit under the Energy Act (2004) 'to maintain and develop the skills for decommissioning and nuclear clean-up'. Although current research is now being reviewed, there is significant evidence to suggest that the age profile in the Site Licence Companies is skewed towards older workers and there is likely to be a skill shortage in 3-5 years. As nuclear clean-up is a national issue; skill shortages also become a national issue in a very real sense. In addition, evidence suggests that the industry needs to be constantly challenged in order to achieve its targets for decommissioning. The NDA has a unique position under the Act. It is both a strategic overseer and direct employer. To this end the 'National Graduate Programme' is aligned to both the NDA's previous succession plans and the needs of the industry. Industry needs leadership that challenges the status quo and moves the UK nuclear industry to become best in class; Industry needs a dedicated to programme to address skills shortages and difficult to recruit areas such as, but not exclusively, estimators, schedulers, contract managers, site engineers, decommissioning technicians, safety monitors; The NDA has indicated a 'commercial and politically savvy' cohort is required to meet its own internal challenges and to ensure sustainability in its own workforce, and to be sensitive to the needs of customers and suppliers alike; Need to create a more diversified workforce in the nuclear industry and also plan for new skills evolving from research and development breakthroughs; Need to ensure that Tier 1, 2, 3 and 4 contractors invest in the leadership and skills for the future. World Class - delivery will be benchmarked against UK based multinational companies who operate in a global graduate attraction and development marketplace. The graduates targeted will be from leading institutions and will have a blend of

  2. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Maya, Jakob

    1987-01-01

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25.degree. C.

  3. High-frequency electrode less lamps for application in atomic absorption analysis

    International Nuclear Information System (INIS)

    Gavare, Z.; Revalde, G.; Skudra, A.; Ganeev, A.; Sholupov, S.

    2004-01-01

    Authors measured and optimised main characteristic of different EDL-s, interesting for their use in atomic absorption spectroscopy: working time, main spectral line intensities and spectral widths, as well as limits of detection for respective elements. In the experiment spectrometer MGA-915 was used. In the table the ultimate limits of detection (LOD) are compered for HF ED lamps and HJC lamps. LOD for HF EDL lamps are 1.5 - 8 times lower than ones for HCL-s

  4. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1987-10-06

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

  5. CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2015-08-31

    This report looks at the photoelectric performance of the same set of lamps assessed in Report 22, using commercially available transformers and dimmers as well as laboratory power supplies providing either AC or DC. The investigation explores several issues related to the testing and use of MR16 lamps in lighting systems and examines the range of performance that is possible for a given lamp model, based on the system to which it is connected.

  6. The Winfrith DSN programme

    International Nuclear Information System (INIS)

    Francescon, S.

    1963-05-01

    The programme, which is written in the Fortran language, solves the Carlson discrete S n approximation to the Boltzmann transport equation in cylindrical geometry. This report describes the input and output facilities of the WINFRITH DSN programme and the associated editing programme WED. (author)

  7. The Winfrith DSN programme

    Energy Technology Data Exchange (ETDEWEB)

    Francescon, S [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-05-15

    The programme, which is written in the Fortran language, solves the Carlson discrete S{sub n} approximation to the Boltzmann transport equation in cylindrical geometry. This report describes the input and output facilities of the WINFRITH DSN programme and the associated editing programme WED. (author)

  8. UNESCO's Ethics Education Programme.

    NARCIS (Netherlands)

    Have, H.A.M.J. ten

    2008-01-01

    Unesco initiated the Ethics Education Programme in 2004 at the request of member states to reinforce and increase the capacities in the area of ethics teaching. The programme is focused on providing detailed information about existing teaching programmes. It also develops and promotes teaching

  9. The Danish Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Ellermann, Thomas; Nøjgaard, Jacob Klenø; Nordstrøm, Claus

    Aarhus University, DCE – Danish Centre for Environment and Energy, 64 pp. Scientific Report from DCE – Danish Centre for Environment and Energy No. 162. http://dce2.au.dk/pub/SR162.pdf......Aarhus University, DCE – Danish Centre for Environment and Energy, 64 pp. Scientific Report from DCE – Danish Centre for Environment and Energy No. 162. http://dce2.au.dk/pub/SR162.pdf...

  10. Monitoring programme of water reservoir Grliste

    International Nuclear Information System (INIS)

    Vuckovic, M; Milenkovic, P.; Lukic, D.

    2002-01-01

    The quality of surface waters is a very important problem incorporated in the environment protection, especially in water resources. The Timok border-land hasn't got sufficient underground and surface waters. This is certificated by the International Association for Water Resource. That was reason for building the water reservoir 'Grliste'. Drinking water from water reservoir 'Grliste' supplies Zajecar and the surroundings. (author)

  11. Application of an antenna excited high pressure microwave discharge to compact discharge lamps

    International Nuclear Information System (INIS)

    Kando, M; Fukaya, T; Ohishi, Y; Mizojiri, T; Morimoto, Y; Shido, M; Serita, T

    2008-01-01

    A novel type of high pressure microwave discharge has been investigated to feed the microwave power at the centre of the compact high pressure discharge lamps using the antenna effect. This method of microwave discharge is named as the antenna excited microwave discharge (AEMD). The 2.45 GHz microwave of around 50 W from the solid state microwave generator can sustain a stable plasma column in the small gap between a couple of antennas fitted on the compact lamp filled with discharge gases at a pressure higher than atmosphere. The AEMD has been applied to a compact metal halide lamp and an extremely high pressure mercury discharge lamp. As a result, the metal halide lamp showed high luminous efficacy of around 130 lm W -1 . The excellent lamp properties obtained here can be explained by the low heating loss at the antennas and the lamp wall. The profiles of the microwave electric field in the lamp and the microwave launcher have been numerically calculated to consider the microwave power supply into the lamp

  12. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Science.gov (United States)

    Langhans, Robert W.

    1994-01-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  13. BAD-LAMP controls TLR9 trafficking and signalling in human plasmacytoid dendritic cells.

    Science.gov (United States)

    Combes, Alexis; Camosseto, Voahirana; N'Guessan, Prudence; Argüello, Rafael J; Mussard, Julie; Caux, Christophe; Bendriss-Vermare, Nathalie; Pierre, Philippe; Gatti, Evelina

    2017-10-13

    Toll-like receptors (TLR) are essential components of the innate immune system. Several accessory proteins, such as UNC93B1, are required for transport and activation of nucleic acid sensing Toll-like receptors in endosomes. Here, we show that BAD-LAMP (LAMP5) controls TLR9 trafficking to LAMP1 + late endosomes in human plasmacytoid dendritic cells (pDC), leading to NF-κB activation and TNF production upon DNA detection. An inducible VAMP3 +/ LAMP2 +/ LAMP1 - endolysosome compartment exists in pDCs from which TLR9 activation triggers type I interferon expression. BAD-LAMP-silencing enhances TLR9 retention in this compartment and consequent downstream signalling events. Conversely, sustained BAD-LAMP expression in pDCs contributes to their lack of type I interferon production after exposure to a TGF-β-positive microenvironment or isolation from human breast tumours. Hence, BAD-LAMP limits interferon expression in pDCs indirectly, by promoting TLR9 sorting to late endosome compartments at steady state and in response to immunomodulatory cues.TLR9 is highly expressed by plasmacytoid dendritic cells and detects nucleic acids, but to discriminate between host and microbial nucleic acids TLR9 is sorted into different endosomal compartments. Here the authors show that BAD-LAMP limits type 1 interferon responses by sorting TLR9 to late endosomal compartments.

  14. There are Many Kinds and Brands of TL Lamp and Ballast Transformer in the Market

    International Nuclear Information System (INIS)

    Koes-Indrakoesoema; Yayan-Andryanto

    2006-01-01

    However, there is still a problem of how to determining the power factor (cos φ) for one of brand of lamp. Lamps with low power factor will consume relatively high reactive power, hence the active power that can be utilized decreases. One of the effort that can be done to improve the level of the lamp's power factor is to install a suitable capacitor with the lamp. The values of the lamp's power factor of a certain brand of lamp will be different if the lamp is connected with different brand of ballast transformer. Therefore, the value of the capacitor that have to be installed to the lamp also must be different depend on the brand of the transformer. This experiment using 2 (two) TL lamp i.e Chiyoda 40 Watt and Philip 36 Watt which has been installed with capacitor 3.6 μF and combination of ballast transformer Philips, National and Siemens and shows that increase the power factor until 0.95. (author)

  15. Loop-mediated isothermal amplification (LAMP) shield for Arduino DNA detection.

    Science.gov (United States)

    Velders, Aldrik H; Schoen, Cor; Saggiomo, Vittorio

    2018-02-01

    Loop-mediated isothermal amplification (LAMP) of DNA is gaining relevance as a method to detect nucleic acids, as it is easier, faster, and more powerful than conventional Polymerase Chain Reaction. However, LAMP is still mostly used in laboratory settings, because of the lack of a cheap and easy, one-button device that can perform LAMP experiments. Here we show how to build and program an Arduino shield for a LAMP and detection of DNA. The here described Arduino Shield is cheap, easy to assemble, to program and use, it is battery operated and the detection of DNA is done by naked-eye so that it can be used in field.

  16. Estimation of mercury amount in the components of spent U-type lamp.

    Science.gov (United States)

    Rhee, Seung-Whee

    2017-05-01

    Spent U-type lamps are strongly encouraged to be separately managed in Korea, because U-type lamps are categorized as a household waste and thereby could not be managed properly. Determination of mercury amount in the components of U-type lamp, such as plastics, glass tube and phosphor powder from 3 U-type lamp manufacturers (A, B and C), is carried out to estimate the mercury content in spent U-type lamps. Regardless of lamp manufacturers, the portion of mercury in phosphor powder was higher than 90%, but that in plastics and others was less than 1%. At an air flow rate of 1.0 L/min, the range of the initial mercury concentration in vapor phase for U-type lamp was between 849 and 2076 µg/m 3 from 3 companies. The estimated mercury amount in vapor phase of U-type lamp was in the range from 0.206 mg for company A to 0.593 mg for company B. And the portion of mercury in vapor phase in the total amount of mercury was estimated in the range from 3.0% for company A to 6.7% for company B. Hence, it is desirable to get rid of mercury from phosphor powder in order to perform U-type lamps recycling.

  17. Which adherence measure - self-report, clinician recorded or pharmacy refill - is best able to predict detectable viral load in a public ART programme without routine plasma viral load monitoring?

    Science.gov (United States)

    Mekuria, Legese A; Prins, Jan M; Yalew, Alemayehu W; Sprangers, Mirjam A G; Nieuwkerk, Pythia T

    2016-07-01

    Combination antiretroviral therapy (cART) suppresses viral replication to an undetectable level if a sufficiently high level of adherence is achieved. We investigated which adherence measurement best distinguishes between patients with and without detectable viral load in a public ART programme without routine plasma viral load monitoring. We randomly selected 870 patients who started cART between May 2009 and April 2012 in 10 healthcare facilities in Addis Ababa, Ethiopia. Six hundred and sixty-four (76.3%) patients who were retained in HIV care and were receiving cART for at least 6 months were included and 642 had their plasma HIV-1 RNA concentration measured. Patients' adherence to cART was assessed according to self-report, clinician recorded and pharmacy refill measures. Multivariate logistic regression model was fitted to identify the predictors of detectable viremia. Model accuracy was evaluated by computing the area under the receiver operating characteristic (ROC) curve. A total of 9.2% and 5.5% of the 642 patients had a detectable viral load of ≥40 and ≥400 RNA copies/ml, respectively. In the multivariate analyses, younger age, lower CD4 cell count at cART initiation, being illiterate and widowed, and each of the adherence measures were significantly and independently predictive of having ≥400 RNA copies/ml. The ROC curve showed that these variables altogether had a likelihood of more than 80% to distinguish patients with a plasma viral load of ≥400 RNA copies/ml from those without. Adherence to cART was remarkably high. Self-report, clinician recorded and pharmacy refill non-adherence were all significantly predictive of detectable viremia. The choice for one of these methods to detect non-adherence and predict a detectable viral load can therefore be based on what is most practical in a particular setting. © 2016 John Wiley & Sons Ltd.

  18. Report of the second research co-ordination meeting on the co-ordinated research programme: rapid instrumental and separation methods for monitoring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    1992-10-01

    The purpose of this Second Research Co-ordinated Meeting (12-16 August 1991) on Rapid Instrumental and Separation Methods for Monitoring Radionuclides in Food and Environmental Samples is to discuss the progress of the programmes since the First Research Co-ordination Meeting, discuss how to validate the methodologies developed (e.g. reference samples, intercomparisons), and outline a schedule for CRP completion by the end of 1992. Radioactive contamination of the environment after a nuclear accident, such as had occurred at Chernobyl, is of serious concern to government officials and members of the general public. In 1990/1991 the Agency was asked to organize the International Chernobyl Project to assess the situation in the USSR. A network of laboratories was organized to carry out the environmental assessment needed for this project. The following recommendations are based on the experience gained by many of the laboratories involved in this project. 1. Maintain a network of analytical laboratories with special skills and experience to provide assessments of radionuclide contamination in the environment in case of a radiological emergency. 2. Methodologies for assessment of contamination in the environment should take into consideration potential trajectories, radioecology, and food chain parameters. 3. Focus on areas of representative sample collection, is situ instrumental and chemical analysis, as well as advanced streamlined laboratory analyses which will facilitate the timeline of an assessment. 4. Conduct intercomparison and testing of technologies, employing standard reference materials and procedures, and field measurements at significantly contaminated area. 5. Conduct training of Member State laboratory personnel through fellowships, special courses, and workshops. 5 refs

  19. Colour-rendition properties of solid-state lamps

    International Nuclear Information System (INIS)

    Zukauskas, A; Vaicekauskas, R; Shur, M S

    2010-01-01

    The applicability of colour-quality metrics to solid-state light sources is validated and the results of the assessment of colour-rendition characteristics of various lamps are presented. The standard colour-rendering index metric or a refined colour-quality scale metric fails to distinguish between two principle colour-rendition properties of illumination: the ability to render object colours with high fidelity and the ability to increase chromatic contrast, especially when the spectra of light sources contain a few narrow-band electroluminescence components. Supplementing these metrics by the known figures of merit that measure the gamut area of a small number of test colour samples does not completely resolve this issue. In contrast, the statistical approach, which is based on sorting a very large number of test colour samples in respect of just-perceivable colour distortions of several kinds, offers a comprehensive assessment of colour-rendition properties of solid-state light sources. In particular, two statistical indices, colour-fidelity index (CFI) and colour-saturation index (CSI), which are the relative numbers of object colours rendered with high fidelity and increased saturation, respectively, are sufficient to reveal and assess three distinct types of solid-state light sources. These are (i) high-fidelity lamps, which cover the entire spectrum with the spectral components present in the wavelength ranges of both 530-610 nm and beyond 610 nm (e.g. trichromatic warm white phosphor-converted (pc) light-emitting diodes (LEDs), red-amber-green-blue LED clusters, complementary clusters of white and coloured LEDs); (ii) colour-saturating lamps, which lack power in the 530-610 nm wavelength range (e.g. red-green-blue or red-cyan-blue LED clusters) and (iii) colour-dulling lamps, which lack power for wavelengths longer than 610 nm (dichromatic daylight pc LEDs and amber-green-blue LED clusters). Owing to a single statistical format, CSI and CFI can be used for

  20. SEM investigation of incandescent lamp mantle structure on durability

    International Nuclear Information System (INIS)

    Gerneke, D.; Lang, C.

    2002-01-01

    Full text: The incandescent mantle as used on pressure and non-pressure liquid fuel lamps has been in use for over 100 years. What remains unexplained is the way in which the resistance to mechanical shock and the decline in tensile strength with usage is experienced. It has been suggested that to improve durability it is necessary to continuously burn a new mantle for the first two to three hours. The known factors in mantle durability and mechanical strength are chemical composition and fabric weave. This study was undertaken to investigate the effects of burning time and temperature on thorium oxide mantles. The operating temperature of mantles on a range of kerosene pressure lamps was measured and found to be between 800 and 1100 deg C. Heat treatments of thorium based Coleman mantles were carried out in a laboratory furnace within these ranges of temperatures for periods ranging from 2 minutes to 2 hours. The mantles were then viewed in a LEO S440 analytical SEM. Results at 800 deg C show a distinct change in surface morphology with increasing exposure time. At the shorter times (2-5 minutes) the surface was relatively smooth. With increased time periods (15 - 120 minutes) the surface was observed to have a large lumpy structure. At 1100 deg C the difference in surface morphology was not apparent between the shortest and longest times. The surface appears much smoother and no lumpy structure was observed. This suggests that when a mantle is operated at the higher temperature of 1100 deg C the structure of the Thorium oxide is quickly transformed into the known stronger amorphous form. This is taken as the observed smooth structure seen in the SEM images of the 1100 deg C samples. Thus the mantle is expected to be more resistant to mechanical shock and have increased durability. Practical field test results confirm these observations. The mantle on a lamp that is operating efficiently, burns brightly, will far outlast a mantle on an inefficient lamp which bums

  1. Colour-rendition properties of solid-state lamps

    Energy Technology Data Exchange (ETDEWEB)

    Zukauskas, A [Institute of Applied Research, Vilnius University, Sauletekio al. 9, bldg. III, Vilnius, LT-10222 (Lithuania); Vaicekauskas, R [Department of Computer Science, Vilnius University, Naugarduko g. 24, Vilnius, LT-03225 (Lithuania); Shur, M S, E-mail: arturas.zukauskas@ff.vu.l [Department of Electrical, Computer, and System Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180 (United States)

    2010-09-08

    The applicability of colour-quality metrics to solid-state light sources is validated and the results of the assessment of colour-rendition characteristics of various lamps are presented. The standard colour-rendering index metric or a refined colour-quality scale metric fails to distinguish between two principle colour-rendition properties of illumination: the ability to render object colours with high fidelity and the ability to increase chromatic contrast, especially when the spectra of light sources contain a few narrow-band electroluminescence components. Supplementing these metrics by the known figures of merit that measure the gamut area of a small number of test colour samples does not completely resolve this issue. In contrast, the statistical approach, which is based on sorting a very large number of test colour samples in respect of just-perceivable colour distortions of several kinds, offers a comprehensive assessment of colour-rendition properties of solid-state light sources. In particular, two statistical indices, colour-fidelity index (CFI) and colour-saturation index (CSI), which are the relative numbers of object colours rendered with high fidelity and increased saturation, respectively, are sufficient to reveal and assess three distinct types of solid-state light sources. These are (i) high-fidelity lamps, which cover the entire spectrum with the spectral components present in the wavelength ranges of both 530-610 nm and beyond 610 nm (e.g. trichromatic warm white phosphor-converted (pc) light-emitting diodes (LEDs), red-amber-green-blue LED clusters, complementary clusters of white and coloured LEDs); (ii) colour-saturating lamps, which lack power in the 530-610 nm wavelength range (e.g. red-green-blue or red-cyan-blue LED clusters) and (iii) colour-dulling lamps, which lack power for wavelengths longer than 610 nm (dichromatic daylight pc LEDs and amber-green-blue LED clusters). Owing to a single statistical format, CSI and CFI can be used for

  2. Glow discharge lamp: a light source for optical emission spectroscopy

    International Nuclear Information System (INIS)

    Vishwanathan, K.S.; Srinivasan, V.; Nalini, S.; Mahalingam, T.R.

    1990-01-01

    A glow discharge lamp based on a modified version of the Grimm design has been fabricated. Its utility as a radiation source for optical emmission spectrography by standardising a method for the analysis of low alloy steels using a set of certified standards from DMRL, Hyderabad, has been demonstrated. A model has been proposed where the sputtering rates of different metals have been correlated with their heats of sublimation, metallic radii and densities. Sputtering rates of ten different metals obtained from literature have been used to test this model, and the correlation appears to be excellent. (author). 19 re fs., 13 figs., 2 tabs

  3. Microstructural analysis of clayey ceramic incorporated with fluorescent lamp glass

    International Nuclear Information System (INIS)

    Morais, A.S.C.; Caldas, T.C.C.; Pereira, P.S.; Monteiro, S.N.; Vieira, C.M.F.

    2011-01-01

    This study aims to evaluate the effect of the incorporation of glass powder fluorescent lamp, from a decontamination process, in the microstructure of clayey ceramic. Formulations were prepared with incorporation of the waste in amounts of up to 10 wt.% into the clayey body. Specimens were prepared by uniaxial mold-press at 20 MPa and then fired at 850 and 1050°C. After firing, the microstructure of the ceramics was evaluated by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the incorporation of glass powder into the clayey body changes the microstructure of the ceramics. (author)

  4. Status quo of ceramic material for metal halide discharge lamps

    International Nuclear Information System (INIS)

    Kappen, Theo G M M

    2005-01-01

    Polycrystalline alumina is an excellent ceramic material for use as the envelope for metal halide discharge lamps. Although this material was introduced in the mid-1960s, and is thus already known for several decades, recent years have seen considerable effort aimed at further development of these ceramic envelope materials. Developments are not only in the field of ceramic shaping technologies, but are also concentrated on the material properties of the ceramic material itself. Optical, mechanical as well as the chemical properties of the ceramic envelope are strongly controlled by the shape as well as the microstructure of the ceramics used

  5. Mercury Flow Through the Mercury-Containing Lamp Sector of the Economy of the United States

    Science.gov (United States)

    Goonan, Thomas G.

    2006-01-01

    Introduction: This Scientific Investigations Report examines the flow of mercury through the mercury-containing lamp sector of the U.S. economy in 2001 from lamp manufacture through disposal or recycling. Mercury-containing lamps illuminate commercial and industrial buildings, outdoor areas, and residences. Mercury is an essential component in fluorescent lamps and high-intensity discharge lamps (high-pressure sodium, mercury-vapor, and metal halide). A typical fluorescent lamp is composed of a phosphor-coated glass tube with electrodes located at either end. Only a very small amount of the mercury is in vapor form. The remainder of the mercury is in the form of either liquid mercury metal or solid mercury oxide (mercury oxidizes over the life of the lamp). When voltage is applied, the electrodes energize the mercury vapor and cause it to emit ultraviolet energy. The phosphor coating absorbs the ultraviolet energy, which causes the phosphor to fluoresce and emit visible light. Mercury-containing lamps provide more lumens per watt than incandescent lamps and, as a result, require from three to four times less energy to operate. Mercury is persistent and toxic within the environment. Mercury-containing lamps are of environmental concern because they are widely distributed throughout the environment and are easily broken in handling. The magnitude of lamp sector mercury emissions, estimated to be 2.9 metric tons per year (t/yr), is small compared with the estimated mercury losses of the U.S. coal-burning and chlor-alkali industries, which are about 70 t/yr and about 90 t/yr, respectively.

  6. Mercury risk from fluorescent lamps in China: current status and future perspective.

    Science.gov (United States)

    Hu, Yuanan; Cheng, Hefa

    2012-09-01

    Energy-efficient lighting is one of the key measures for addressing electric power shortages and climate change mitigation, and fluorescent lamps are expected to dominate the lighting market in China over the next several years. This review presents an overview on the emissions and risk of mercury from fluorescent lamps during production and disposal, and discusses measures for reducing the mercury risk through solid waste management and source reduction. Fluorescent lamps produced in China used to contain relatively large amounts of mercury (up to 40 mg per lamp) due to the prevalence of liquid mercury dosing, which also released significant amounts of mercury to the environment. Upgrade of the mercury dosing technologies and manufacturing facilities had significantly reduced the mercury contents in fluorescent lamps, with most of them containing less than 10 or 5mg per lamp now. Occupational hygiene studies showed that mercury emissions occurred during fluorescent lamp production, particularly in the facilities using liquid mercury dosing, which polluted the environmental media at and surrounding the production sites and posed chronic health risk to the workers by causing neuropsychological and motor impairments. It is estimated that spent fluorescent lamps account for approximately 20% of mercury input in the MSW in China. Even though recycling of fluorescent lamps presents an important opportunity to capture the mercury they contain, it is difficult and not cost-effective at reducing the mercury risk under the broader context of mercury pollution control in China. In light of the significant mercury emissions associated with electricity generation in China, we propose that reduction of mercury emissions and risk associated with fluorescent lamps should be achieved primarily through lowering their mercury contents by the manufacturers while recycling programs should focus on elemental mercury-containing waste products instead of fluorescent lamps to recapture

  7. Photovoltaic programme, edition 2004

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This comprehensive publication issued by the Swiss Federal Office of Energy's Photovoltaics (PV) Programme presents an overview (in English) of activities and projects in the photovoltaics research and pilot and demonstration areas in Switzerland for the year 2003. Progress in future solar cell technologies as well as in the area of modules, building integration and system technologies is summarised. Also, national and international co-operation and multi-national pilot and demonstration projects are commented on. Associated projects such as eco-balances for PV systems, forecasting and modelling tools as well as system monitoring tools are discussed. In the area of pilot and demonstration projects, component development, PV integration in sloping roofs, on flat roofs and on facades as well as further PV plant are looked at. Also, measurement campaigns, studies, statistics and other PV-related topics are summarised. This volume presents a list of 92 projects in the PV area including the appropriate Internet links and is completed with a collection of project abstracts.

  8. Photovoltaic programme, edition 2004

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This comprehensive publication issued by the Swiss Federal Office of Energy's Photovoltaics (PV) Programme presents an overview (in English) of activities and projects in the photovoltaics research and pilot and demonstration areas in Switzerland for the year 2003. Progress in future solar cell technologies as well as in the area of modules, building integration and system technologies is summarised. Also, national and international co-operation and multi-national pilot and demonstration projects are commented on. Associated projects such as eco-balances for PV systems, forecasting and modelling tools as well as system monitoring tools are discussed. In the area of pilot and demonstration projects, component development, PV integration in sloping roofs, on flat roofs and on facades as well as further PV plant are looked at. Also, measurement campaigns, studies, statistics and other PV-related topics are summarised. This volume presents a list of 92 projects in the PV area including the appropriate Internet links and is completed with a collection of project abstracts.

  9. Fabry-Perot measurements of barium temperature in fluorescent lamps

    International Nuclear Information System (INIS)

    Hadrath, S; Garner, R

    2010-01-01

    A scanning Fabry-Perot interferometer (FPI) is used to determine the temperature of barium atoms that are liberated from the electrodes of fluorescent lamps during their steady-state operation. Barium, a constituent of the work function lowering emitter material that is placed on the tungsten coil that forms the electrode, is liberated primarily by evaporation from the hot (∼1300 K) thermionic electrode. However, there may be situations or modes of operation in which barium is, in addition, sputtered, a condition which may lead to increased end-darkening, shortened life and increased mercury consumption in the lamp. Using the FPI diagnostic, the occurrence of sputtering is inferred when barium temperatures are much greater than the electrode temperature. The FPI diagnostic senses resonance radiation (λ = 553 nm) emitted by barium atoms excited in the low pressure discharge environment, and infers temperature from the Doppler broadened linewidth. The diagnostic has proven to be successful in a number of situations. Measurements have been made on rare gas discharges and on Hg-argon discharges for different discharge currents, gas pressures and auxiliary coil currents. Measurements are phase resolved for ac-driven discharges.

  10. Gluing for Raman lidar systems using the lamp mapping technique.

    Science.gov (United States)

    Walker, Monique; Venable, Demetrius; Whiteman, David N

    2014-12-20

    In the context of combined analog and photon counting (PC) data acquisition in a Lidar system, glue coefficients are defined as constants used for converting an analog signal into a virtual PC signal. The coefficients are typically calculated using Lidar profile data taken under clear, nighttime conditions since, in the presence of clouds or high solar background, it is difficult to obtain accurate glue coefficients from Lidar backscattered data. Here we introduce a new method in which we use the lamp mapping technique (LMT) to determine glue coefficients in a manner that does not require atmospheric profiles to be acquired and permits accurate glue coefficients to be calculated when adequate Lidar profile data are not available. The LMT involves scanning a halogen lamp over the aperture of a Lidar receiver telescope such that the optical efficiency of the entire detection system is characterized. The studies shown here involve two Raman lidar systems; the first from Howard University and the second from NASA/Goddard Space Flight Center. The glue coefficients determined using the LMT and the Lidar backscattered method agreed within 1.2% for the water vapor channel and within 2.5% for the nitrogen channel for both Lidar systems. We believe this to be the first instance of the use of laboratory techniques for determining the glue coefficients for Lidar data analysis.

  11. Changing lamp type and position to improve lighting quality

    Science.gov (United States)

    Anizar; Syahputri, K.; Sari, RM; Rizkya, I.; Hardianti, DA

    2018-03-01

    This study investigates the lighting quality on the production floor in a cigarette paper industry by measuring illumination level and luminance. Cigarette paper inspection is performed manually by operators, and the criteria of defects are the cigarette paper has a hole, is rough and dirty. Operators complain that the room is pretty dark, which makes them unable to see clearly the cigarette paper defect. The government of Indonesia Health Ministerial Decree No 1405 The Year 2002 states that illumination level for continuous manual labor is 200 lux. Illumination level is measured for four days at 08.00, 10.00, 12.30, and 14.00 o’clock with 4 in 1 environmental meter. From the measurement result, it is found that using 7 LED lamps of 60 Watts can produce average illumination level of 70 lux. Low illuminance is caused by illumination level that does not meet the need 0f 569.759 lumen. Alternatives that can be used to increase lumen number are changing lamp type and position. One of the possibilities is using 24 LED of 138 Watts set 5.7 meters apart from one another can meet this demand. Another is using 5 LED of 150 Watts installed above the field of work.

  12. Evaluation of European energy behavioural change programmes

    Energy Technology Data Exchange (ETDEWEB)

    Gynther, L.; Mikkonen, I. [Motiva Oy, Urho Kekkosenkatu 4-6 A, 00100 Helsinki (Finland); Smits, A. [NL Agency, Swentiboldstraat 21, 6137 AE Sittard (Netherlands)

    2012-01-15

    This article is based on the findings of the BEHAVE Project (Evaluation of Energy Behavioural Change Programmes) which was supported by the European Commission under the EU Intelligent Energy-Europe (IEE) Programme. The project started with a review of behavioural theories and their applicability in the development and evaluation of energy-related behavioural change programmes, progressed to a case study analysis and finished with a publication of guidelines for programme developers and policy makers. This paper concentrates on the results of the case study analysis and the recommendations arising from it. In the case study analysis, information was collected on almost 100 cases aiming at behavioural change in energy use from 11 European countries. More detailed information was collected on 41 cases which were subject to meta-analysis to identify success factors and weak points and to gather information on the current evaluation practices in such programmes. The meta-analysis was carried out in five phases: context (pre-planning), planning, implementation, monitoring and evaluation. Planning and evaluation were recognised as two of the most critical phases. Many of the programmes operated with quite formal plans but were typically not based on scientific theories or evidence. In many cases, there was lack of market segmentation; the goals were not targeted and the programmes tried to offer 'everything to everybody'. A multitude of ex-post evaluation methods for programme impacts were reported ranging from participant surveys, testing and comparison with control groups to top-down method evaluating the impact of several programmes focusing on the same target group. Process evaluation (25 cases) was slightly less common than impact evaluation (29 cases). Evaluation of the cost-effectiveness of the programmes was a rarity, most likely due to difficulties in quantitative impact evaluation.

  13. Breakthrough of ultraviolet light from various brands of fluorescent lamps: Lethal effects on DNA repair-defective bacteria

    International Nuclear Information System (INIS)

    Hartman, P.E.; Biggley, W.H.

    1996-01-01

    In a comparative study of 17 pairs of 15 W fluorescent lamps intended for use in homes and purchased in local stores, we detect over 10-fold differences in UVB + UVC emissions between various lamps. This breakthrough of ultraviolet (UV) light is in part correlated with ability of lamps to kill DNA repair-defective recA - uvrB - Salmonella. Relative proficiency of lamps in eliciting photoreactivation of UV-induced DNA lesions also plays a prominent role in the relative rates of bacterial inactivation by emissions from different lamps. Lamps made in Chile, such as Phillips brand lamps and one type of General Electric lamp, produce far less UVB + UVC and fail to kill recA - uvrB - bacteria. In contrast, all tested lamps manufactured in the USA, Hungary, and Japan exhibit readily observed deleterious biological effects. When an E. coli recA - uvrB - phr - (photolyase-negative) triple mutant is used for assay, lethal radiations are detected from all lamps, and single-hit exponential inactivation rates rather closely correlate to amount of directly measured UVB + UVC output of each pair of lamps. Although all lamps tested may meet international and Unite States standards for radiation safely, optimal practices in lamp manufacture are clearly capable of decreasing human exposure to indoor UV light. 38 refs., 3 figs., 1 tab

  14. Effect of capacitor loss on discharging characteristics of xenon flash lamp

    International Nuclear Information System (INIS)

    Zhang Chu; Lin Dejiang; Xu Chunmei; Shen Hongbin; Chen Xiaohan

    2012-01-01

    The effect of storage capacitor's loss on the discharging characteristics of the xenon flash lamp was studied, and the xenon flash lamp discharging circuit was analyzed and improved. The capacitor can be equivalent to a series of an ideal capacitor and loss resistance. The improved formula of the xenon lamp discharging characteristics was given when actual capacitance loss is not zero, and the xenon lamp discharging current and discharging power are calculated and analyzed in detail with the increase of the capacitor loss. The results show that the increase of loss will lead to the decrease of xenon lamp discharging current and peak power and the xenon lamp flash time, and influence laser pumping efficiency. The loss will also lead to the capacitor inverse charging in LC discharging circuit; this will influence normal working of the capacitor and decrease the lift of the xenon lamp. The actual energy storage capacitor charging and discharging experiments show that the increase of capacitor loss will lead to the decrease of xenon lamp light-emitting waveform peak, shortening of the flash time and increase of the electrode sputter, thus verity, the reasonableness of theoretical analysis. In addition, the experiments show that environmental factors have very significant impact on the increase of the storage capacitor loss. (authors)

  15. [Study on the discharge properties of xeon flash lamp and experimental measurement].

    Science.gov (United States)

    Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei

    2014-07-01

    The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.

  16. Regulated-current dc power supply for gaseous-discharge lamps

    Science.gov (United States)

    Freeman, W.; Huguenin, D.

    1970-01-01

    Controlled current source having a high output resistance feeds continuous-flow hydrogen lamps in vacuum-ultraviolet photometric equipment. The power supply, also used with low-pressure sealed lamps, has a short recovery time and smooth regulation without overshoot.

  17. Time resolved Thomson scattering measurements on a high pressure mercury lamp

    NARCIS (Netherlands)

    Vries, de N.; Zhu, Xiao-Yan; Kieft, E.R.; Mullen, van der J.J.A.M.

    2005-01-01

    Time resolved Thomson scattering (TS) measurements have been performed on an ac driven high pressure mercury lamp. For this high intensity discharge (HID) lamp, TS is coherent and a coherent fitting routine, including rotational Raman calibration, was used to determine ne and Te from the measured

  18. Analysis of compact and portable goniospectrometer system for test of LED lamps

    DEFF Research Database (Denmark)

    Dam-Hansen, Carsten; Amdemeskel, Mekbib Wubishet; Thorseth, Anders

    2015-01-01

    measurements in a near-field goniophotometer. A collection of six different types of directional and non-directional integrated LED lamps with three samples of each were used as test devices. It is shown that the main uncertainty comes from the inadequate thermal stabilisation of the LED lamps. With pre...

  19. The results of nocturnal visual surveys are influenced by lamp properties

    Science.gov (United States)

    Lardner, B.; Savidge, J.A.; Rodda, G.H.; Reed, R.N.; Adams, A.A.Y.

    2009-01-01

    We conducted standardized visual searches at night for brown treesnakes (Boiga irregularis) and geckos, where we alternated between spotlight and floodlight lamps. Floodlights rendered us 25% more snakes and 71% more geckos than did spotlights. We show data on searcher variability and discuss what might affect the relative benefit of different lamp types. ?? 2009 Brill Academic Publishers.

  20. The evolving price of household LED lamps: Recent trends and historical comparisons for the US market

    Energy Technology Data Exchange (ETDEWEB)

    Gerke, Brian F.; Ngo, Allison T.; Alstone, Andrea L.; Fisseha, Kibret S.

    2014-10-14

    In recent years, household LED light bulbs (LED A lamps) have undergone a dramatic price decline. Since late 2011, we have been collecting data, on a weekly basis, for retail offerings of LED A lamps on the Internet. The resulting data set allows us to track the recent price decline in detail. LED A lamp prices declined roughly exponentially with time in 2011-2014, with decline rates of 28percent to 44percent per year depending on lumen output, and with higher-lumen lamps exhibiting more rapid price declines. By combining the Internet price data with publicly available lamp shipments indices for the US market, it is also possible to correlate LED A lamp prices against cumulative production, yielding an experience curve for LED A lamps. In 2012-2013, LED A lamp prices declined by 20-25percent for each doubling in cumulative shipments. Similar analysis of historical data for other lighting technologies reveals that LED prices have fallen significantly more rapidly with cumulative production than did their technological predecessors, which exhibited a historical decline of 14-15percent per doubling of production.