WorldWideScience

Sample records for monitor units mus

  1. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  2. Identification of management units using population genetic data

    NARCIS (Netherlands)

    Palsboll, Per J.; Berube, Martine; Allendorf, Fred W.

    The identification of management units (MUs) is central to the management of natural populations and is crucial for monitoring the effects of human activity upon species abundance. Here, we propose that the identification of MUs from population genetic data should be based upon the amount of genetic

  3. Independent calculation of monitor units for VMAT and SPORT

    International Nuclear Information System (INIS)

    Chen, Xin; Bush, Karl; Ding, Aiping; Xing, Lei

    2015-01-01

    Purpose: Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulated arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT). Methods: The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms. Results: For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours

  4. Independent calculation of monitor units for VMAT and SPORT

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xin; Bush, Karl; Ding, Aiping; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States)

    2015-02-15

    Purpose: Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulated arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT). Methods: The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms. Results: For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours

  5. One normal void and residual following MUS surgery is all that is necessary in most patients.

    Science.gov (United States)

    Ballard, Paul; Shawer, Sami; Anderson, Colette; Khunda, Aethele

    2018-04-01

    There is considerable variation worldwide on how the assessment of voiding function is performed following midurethral sling (MUS) surgery. There is potentially a financial cost, and reduction in efficiency when patient discharge is delayed. Using our current practice of two normal void and residual (V&R) readings before discharge, the aim of this retrospective study was to evaluate the likelihood of an abnormal second V&R test if the first V&R test was normal in order to determine if a policy of discharge after only one satisfactory V&R test is reasonable. Data from 400 patients who had had MUS surgery with or without other procedures were collected. Our unit protocol included two consecutive voids of greater than 200 ml with residuals less than 150 ml before discharge. The patients were divided into the following groups: MUS only, MUS plus anterior colporrhaphy (AR) plus any other procedures (MUS/AR), and MUS with any non-AR procedures (MUS+). Complete datasets were available for 335 patients. Once inadequate tests (low volume voids <200 ml) had been excluded (28% overall), the likelihood of an abnormal second V&R test if the first test was normal was 7.1% overall, but 3.6% for MUS, 11.5% for MUS/AR and 8.6% for MUS+. The findings in the MUS-only group indicate that it is probably safe to discharge patients after one satisfactory V&R test, as long as safety measures such as 'open access' are available so that patients have unhindered readmission if problems arise.

  6. Mutations at the mei-41, mus(1)101, mus(1)103, mus(2)205 and mus(3)310 loci of Drosophila exhibit differential UDS responses with different DNA-damaging agents

    International Nuclear Information System (INIS)

    Dusenbery, R.L.

    1987-01-01

    5 mutagen-sensitive mutants of Drosophila melanogaster, reported to perform normal or only slightly reduced excision repair of UV damage, were examined by an unscheduled DNA synthesis (UDS) assay. 2 mutants, classified as completely or partially proficient for both excision and postreplication repair of UV damage, mus(1)103 and mus(2)205, were found to give positive UDS responses only for UV damage. These mutants exhibit no measurable UDS activity following DNA damage by several different alkylating agents and X-rays. 3 mutants, classified as having no defect in excision repair, but measurable defects in postreplication repair of UV damage, exhibit 3 different response patterns. The mutant mei-41 exhibits a highly positive UDS response following damage by all agents, consistent with its prior classification as excision-repair-proficient, but postreplication-repair-deficient for UV damage. The mutant mus(1)101, however, exhibits a strong positive UDS response following only UV damage and appears to be blocked in the excision repair of damage produced by both alkylating agents and X-irradiation. Finally, mus(3)310 exhibits no UDS response to alkylation, X-ray or UV damage. This is not consistent with its previous classification. Results obtained w0272the qualitative in vitro UDS assay are entirely consistent with the results from two separate in vivo measures of excision repair deficiency followign DNA damage, larval hypersensitivity to killing and hypermutability in the sex-linked recessive lethal test. (Auth.)

  7. Repeat associated mechanisms of genome evolution and function revealed by the Mus caroli and Mus pahari genomes

    Science.gov (United States)

    Thybert, David; Roller, Maša; Navarro, Fábio C.P.; Fiddes, Ian; Streeter, Ian; Feig, Christine; Martin-Galvez, David; Kolmogorov, Mikhail; Janoušek, Václav; Akanni, Wasiu; Aken, Bronwen; Aldridge, Sarah; Chakrapani, Varshith; Chow, William; Clarke, Laura; Cummins, Carla; Doran, Anthony; Dunn, Matthew; Goodstadt, Leo; Howe, Kerstin; Howell, Matthew; Josselin, Ambre-Aurore; Karn, Robert C.; Laukaitis, Christina M.; Jingtao, Lilue; Martin, Fergal; Muffato, Matthieu; Nachtweide, Stefanie; Quail, Michael A.; Sisu, Cristina; Stanke, Mario; Stefflova, Klara; Van Oosterhout, Cock; Veyrunes, Frederic; Ward, Ben; Yang, Fengtang; Yazdanifar, Golbahar; Zadissa, Amonida; Adams, David J.; Brazma, Alvis; Gerstein, Mark; Paten, Benedict; Pham, Son; Keane, Thomas M.; Odom, Duncan T.; Flicek, Paul

    2018-01-01

    Understanding the mechanisms driving lineage-specific evolution in both primates and rodents has been hindered by the lack of sister clades with a similar phylogenetic structure having high-quality genome assemblies. Here, we have created chromosome-level assemblies of the Mus caroli and Mus pahari genomes. Together with the Mus musculus and Rattus norvegicus genomes, this set of rodent genomes is similar in divergence times to the Hominidae (human-chimpanzee-gorilla-orangutan). By comparing the evolutionary dynamics between the Muridae and Hominidae, we identified punctate events of chromosome reshuffling that shaped the ancestral karyotype of Mus musculus and Mus caroli between 3 and 6 million yr ago, but that are absent in the Hominidae. Hominidae show between four- and sevenfold lower rates of nucleotide change and feature turnover in both neutral and functional sequences, suggesting an underlying coherence to the Muridae acceleration. Our system of matched, high-quality genome assemblies revealed how specific classes of repeats can play lineage-specific roles in related species. Recent LINE activity has remodeled protein-coding loci to a greater extent across the Muridae than the Hominidae, with functional consequences at the species level such as reproductive isolation. Furthermore, we charted a Muridae-specific retrotransposon expansion at unprecedented resolution, revealing how a single nucleotide mutation transformed a specific SINE element into an active CTCF binding site carrier specifically in Mus caroli, which resulted in thousands of novel, species-specific CTCF binding sites. Our results show that the comparison of matched phylogenetic sets of genomes will be an increasingly powerful strategy for understanding mammalian biology. PMID:29563166

  8. Evolution of major milk proteins in Mus musculus and Mus spretus mouse species: a genoproteomic analysis

    Directory of Open Access Journals (Sweden)

    Panthier Jean-Jacques

    2011-01-01

    Full Text Available Abstract Background Due to their high level of genotypic and phenotypic variability, Mus spretus strains were introduced in laboratories to investigate the genetic determinism of complex phenotypes including quantitative trait loci. Mus spretus diverged from Mus musculus around 2.5 million years ago and exhibits on average a single nucleotide polymorphism (SNP in every 100 base pairs when compared with any of the classical laboratory strains. A genoproteomic approach was used to assess polymorphism of the major milk proteins between SEG/Pas and C57BL/6J, two inbred strains of mice representative of Mus spretus and Mus musculus species, respectively. Results The milk protein concentration was dramatically reduced in the SEG/Pas strain by comparison with the C57BL/6J strain (34 ± 9 g/L vs. 125 ± 12 g/L, respectively. Nine major proteins were identified in both milks using RP-HPLC, bi-dimensional electrophoresis and MALDI-Tof mass spectrometry. Two caseins (β and αs1 and the whey acidic protein (WAP, showed distinct chromatographic and electrophoresis behaviours. These differences were partly explained by the occurrence of amino acid substitutions and splicing variants revealed by cDNA sequencing. A total of 34 SNPs were identified in the coding and 3'untranslated regions of the SEG/Pas Csn1s1 (11, Csn2 (7 and Wap (8 genes. In addition, a 3 nucleotide deletion leading to the loss of a serine residue at position 93 was found in the SEG/Pas Wap gene. Conclusion SNP frequencies found in three milk protein-encoding genes between Mus spretus and Mus musculus is twice the values previously reported at the whole genome level. However, the protein structure and post-translational modifications seem not to be affected by SNPs characterized in our study. Splicing mechanisms (cryptic splice site usage, exon skipping, error-prone junction sequence, already identified in casein genes from other species, likely explain the existence of multiple αs1-casein

  9. Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Kwang-Ho; Kang, Sei-Kwon; Lee, MeYeon; Kim, Su SSan; Park, SoAh; Hwang, Tae-Jin; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik; Suh, Tae-Suk [Department of Radiation Oncology, Hallym University College of Medicine, Seoul, 431070 (Korea, Republic of) and Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of); Department of Radiation Oncology, Hallym University College of Medicine, Seoul 431070 (Korea, Republic of); Department of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul 137701 (Korea, Republic of)

    2010-03-15

    Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

  10. Repeat associated mechanisms of genome evolution and function revealed by the Mus caroli and Mus pahari genomes.

    Science.gov (United States)

    Thybert, David; Roller, Maša; Navarro, Fábio C P; Fiddes, Ian; Streeter, Ian; Feig, Christine; Martin-Galvez, David; Kolmogorov, Mikhail; Janoušek, Václav; Akanni, Wasiu; Aken, Bronwen; Aldridge, Sarah; Chakrapani, Varshith; Chow, William; Clarke, Laura; Cummins, Carla; Doran, Anthony; Dunn, Matthew; Goodstadt, Leo; Howe, Kerstin; Howell, Matthew; Josselin, Ambre-Aurore; Karn, Robert C; Laukaitis, Christina M; Jingtao, Lilue; Martin, Fergal; Muffato, Matthieu; Nachtweide, Stefanie; Quail, Michael A; Sisu, Cristina; Stanke, Mario; Stefflova, Klara; Van Oosterhout, Cock; Veyrunes, Frederic; Ward, Ben; Yang, Fengtang; Yazdanifar, Golbahar; Zadissa, Amonida; Adams, David J; Brazma, Alvis; Gerstein, Mark; Paten, Benedict; Pham, Son; Keane, Thomas M; Odom, Duncan T; Flicek, Paul

    2018-04-01

    Understanding the mechanisms driving lineage-specific evolution in both primates and rodents has been hindered by the lack of sister clades with a similar phylogenetic structure having high-quality genome assemblies. Here, we have created chromosome-level assemblies of the Mus caroli and Mus pahari genomes. Together with the Mus musculus and Rattus norvegicus genomes, this set of rodent genomes is similar in divergence times to the Hominidae (human-chimpanzee-gorilla-orangutan). By comparing the evolutionary dynamics between the Muridae and Hominidae, we identified punctate events of chromosome reshuffling that shaped the ancestral karyotype of Mus musculus and Mus caroli between 3 and 6 million yr ago, but that are absent in the Hominidae. Hominidae show between four- and sevenfold lower rates of nucleotide change and feature turnover in both neutral and functional sequences, suggesting an underlying coherence to the Muridae acceleration. Our system of matched, high-quality genome assemblies revealed how specific classes of repeats can play lineage-specific roles in related species. Recent LINE activity has remodeled protein-coding loci to a greater extent across the Muridae than the Hominidae, with functional consequences at the species level such as reproductive isolation. Furthermore, we charted a Muridae-specific retrotransposon expansion at unprecedented resolution, revealing how a single nucleotide mutation transformed a specific SINE element into an active CTCF binding site carrier specifically in Mus caroli , which resulted in thousands of novel, species-specific CTCF binding sites. Our results show that the comparison of matched phylogenetic sets of genomes will be an increasingly powerful strategy for understanding mammalian biology. © 2018 Thybert et al.; Published by Cold Spring Harbor Laboratory Press.

  11. Detection of Highly-Absorbed X-rays from Nova Mus 2018 with Swift

    Science.gov (United States)

    Nelson, Thomas; Kuin, Paul; Mukai, Koji; Page, Kim; Chomiuk, Laura; Kawash, Adam; Sokoloski, J. L.; Linford, Justin; Rupen, Michael P.; Mioduszewski, Amy

    2018-03-01

    We report the detection of X-rays from Nova Mus 2018 with the Swift XRT instrument. We have been carrying out weekly monitoring of the nova with Swift since its discovery on 2018 Jan 15 (see ATel #11220), and observations up to 2018 Feb 24 yielded X-ray non-detections.

  12. Effects of mutagen-sensitive mus mutations on spontaneous mitotic recombination in Aspergillus.

    Science.gov (United States)

    Zhao, P; Kafer, E

    1992-04-01

    Methyl methane-sulfonate (MMS)-sensitive, radiation-induced mutants of Aspergillus were shown to define nine new DNA repair genes, musK to musS. To test mus mutations for effects on mitotic recombination, intergenic crossing over was assayed between color markers and their centromeres, and intragenic recombination between two distinguishable adE alleles. Of eight mutants analyzed, four showed significant deviations from mus+ controls in both tests. Two mutations, musK and musL, reduced recombination, while musN and musQ caused increases. In contrast, musO diploids produced significantly higher levels only for intragenic recombination. Effects were relatively small, but averages between hypo- and hyperrec mus differed 15-20-fold. In musL diploids, most of the rare color segregants resulted from mitotic malsegregation rather than intergenic crossing over. This indicates that the musL gene product is required for recombination and that DNA lesions lead to chromosome loss when it is deficient. In addition, analysis of the genotypes of intragenic (ad+) recombinants showed that the musL mutation specifically reduced single allele conversion but increased complex conversion types (especially recombinants homozygous for ad+). Similar analysis revealed differences between the effects of two hyperrec mutations; musN apparently caused high levels solely of mitotic crossing over, while musQ increased various conversion types but not reciprocal crossovers. These results suggest that mitotic gene conversion and crossing over, while generally associated, are affected differentially in some of the mus strains of Aspergillus nidulans.

  13. Dosimetric accuracy at low monitor unit setting in electron beams at different dose rates

    International Nuclear Information System (INIS)

    Ravikumar, M.; Ravichandran, R.; Supe, Sanjay S.; Sharma, Anil K.

    1999-01-01

    As electron beam with low monitor unit (LMU) settings are used in some dosimetric studies, better understanding of accuracy in dose delivery at LMU setting is necessary. The dose measurements were carried out with 0.6 cm 3 farmer type ion chamber at d max in a polystyrene phantom. Measurements at different MUs show that the dose linearity ratio (DLR) increases as the MU setting decreases below 20 MU and DLRs are found to increase when the incident electron beams have higher energies. The increase in DLR is minimum for low dose rate setting for all five electron beam energies (6, 9, 12, 16 and 20 MeV). As the variation in dose delivery is machine-specific, a detailed study should be conducted before the low MU setting is implemented. Since errors in dose delivery are high at higher dose rates, low dose rate may be better at low MU unit setting. (author)

  14. Effects of Mutagen-Sensitive Mus Mutations on Spontaneous Mitotic Recombination in Aspergillus

    OpenAIRE

    Zhao, P.; Kafer, E.

    1992-01-01

    Methyl methane-sulfonate (MMS)-sensitive, radiation-induced mutants of Aspergillus were shown to define nine new DNA repair genes, musK to musS. To test mus mutations for effects on mitotic recombination, intergenic crossing over was assayed between color markers and their centromeres, and intragenic recombination between two distinguishable adE alleles. Of eight mutants analyzed, four showed significant deviations from mus(+) controls in both tests. Two mutations, musK and musL, reduced reco...

  15. Phenotypic and epistatic grouping of hypo- and hyper-rec mus mutants in Aspergillus.

    Science.gov (United States)

    Kafer, E; Chae, S K

    1994-03-01

    The mutants musK to musS of Aspergillus nidulans are sensitive to methyl-methanesulfonate (MMS) and several of them are meiotic-defective and alter mitotic recombination frequencies. All were found to be cross-sensitive to 4-nitro-quinoline-N-oxide (4-NQO) but unexpectedly none of them was hypersensitive to gamma-rays and few to UV light. Double mus; uvs mutants were constructed to test for interactions with uvs mutations of the four epistatic groups of Aspergillus, "UvsF", "UvsC", "UvsI", and "UvsB". All meiotic-defective mus mutations caused some lethal interactions, usually with uvsF. None of them showed epistasis with UvsF or UvsB group mutants and one, musO, may represent a new group. Three mus mutations that affect recombination were assigned to the UvsC group, namely musN and K, and also musL which is recombination-defective and closely resembles uvsC. While uvsC mutants are mutators and lack UV-mutagenesis, most mus mutants had no effects on mutation. Only musR, which appeared epistatic with uvsI, showed reduced UV-reversion frequencies similar to uvsI. The recombination-proficient mus mutants appeared to be epistatic with more than one group, but in several cases sensitivities were slight and overlaps insufficient to obtain corroborating results with MMS and 4-NQO.

  16. MUS81 is associated with cell proliferation and cisplatin sensitivity in serous ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Suhong; Zheng, Hui [Department of Clinical Laboratory, Fudan University Shanghai Cancer Center, Shanghai (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai (China); Wen, Xuemei [Department of Oncology, Shanghai Medical College, Fudan University, Shanghai (China); Sun, Jiajun; Wang, Yanchun; Gao, Xiang; Guo, Lin [Department of Clinical Laboratory, Fudan University Shanghai Cancer Center, Shanghai (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai (China); Lu, Renquan, E-mail: lurenquan@126.com [Department of Clinical Laboratory, Fudan University Shanghai Cancer Center, Shanghai (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai (China)

    2016-08-05

    The dysfunction of DNA damage repair (DDR) pathway contributes to tumorigenesis and drug-resistance in cancer. MUS81 is a member of the conserved xeroderma pigmentosum group F (XPF) family protein of endonucleases, which is important to the DDR pathway. However, the role of MUS81 in the development of ovarian cancer remains uncertain. To explore the expression of MUS81 and its association to serous ovarian cancer (SOC), 43 biopsies of SOC patients were detected by qRT-PCR, and 29 specimens were further performed by immunohistochemistry analysis. Here, we observed that MUS81 was over-expressed in SOC tissues at both transcript and protein levels, and the expression level of MUS81 protein in ovarian cancer cell lines was also higher than that in human normal ovarian surface epithelial cell line (HOSEpiC). We also found that down-regulation of MUS81 expression in ovarian cancer cells inhibited cell proliferation and colony formation ability, and influenced cell cycle progression. Moreover, inhibition of MUS81 expression induced cellular senescence and enhanced the antitumor effect of cisplatin. Down-regulation of MUS81 expression could suppress the growth and development of SOC. These results indicate that MUS81 might play important roles in the progression of SOC and influence the antitumor effect of cisplatin. - Highlights: • MUS81 was overexpression in serous ovarian cancer (SOC). • Meanwhile down-regulation of inhibited cell proliferation and influenced cell cycle progression. • Inhibition of MUS81 induced cell cellular senescence and enhanced the antitumor effect of cisplatin. • Down-regulation of MUS81 expression could suppress the growth and development of SOC.

  17. MUS81 is associated with cell proliferation and cisplatin sensitivity in serous ovarian cancer

    International Nuclear Information System (INIS)

    Xie, Suhong; Zheng, Hui; Wen, Xuemei; Sun, Jiajun; Wang, Yanchun; Gao, Xiang; Guo, Lin; Lu, Renquan

    2016-01-01

    The dysfunction of DNA damage repair (DDR) pathway contributes to tumorigenesis and drug-resistance in cancer. MUS81 is a member of the conserved xeroderma pigmentosum group F (XPF) family protein of endonucleases, which is important to the DDR pathway. However, the role of MUS81 in the development of ovarian cancer remains uncertain. To explore the expression of MUS81 and its association to serous ovarian cancer (SOC), 43 biopsies of SOC patients were detected by qRT-PCR, and 29 specimens were further performed by immunohistochemistry analysis. Here, we observed that MUS81 was over-expressed in SOC tissues at both transcript and protein levels, and the expression level of MUS81 protein in ovarian cancer cell lines was also higher than that in human normal ovarian surface epithelial cell line (HOSEpiC). We also found that down-regulation of MUS81 expression in ovarian cancer cells inhibited cell proliferation and colony formation ability, and influenced cell cycle progression. Moreover, inhibition of MUS81 expression induced cellular senescence and enhanced the antitumor effect of cisplatin. Down-regulation of MUS81 expression could suppress the growth and development of SOC. These results indicate that MUS81 might play important roles in the progression of SOC and influence the antitumor effect of cisplatin. - Highlights: • MUS81 was overexpression in serous ovarian cancer (SOC). • Meanwhile down-regulation of inhibited cell proliferation and influenced cell cycle progression. • Inhibition of MUS81 induced cell cellular senescence and enhanced the antitumor effect of cisplatin. • Down-regulation of MUS81 expression could suppress the growth and development of SOC.

  18. Phosphorylation by CK2 regulates MUS81/EME1 in mitosis and after replication stress.

    Science.gov (United States)

    Palma, Anita; Pugliese, Giusj Monia; Murfuni, Ivana; Marabitti, Veronica; Malacaria, Eva; Rinalducci, Sara; Minoprio, Anna; Sanchez, Massimo; Mazzei, Filomena; Zolla, Lello; Franchitto, Annapaola; Pichierri, Pietro

    2018-06-01

    The MUS81 complex is crucial for preserving genome stability through the resolution of branched DNA intermediates in mitosis. However, untimely activation of the MUS81 complex in S-phase is dangerous. Little is known about the regulation of the human MUS81 complex and how deregulated activation affects chromosome integrity. Here, we show that the CK2 kinase phosphorylates MUS81 at Serine 87 in late-G2/mitosis, and upon mild replication stress. Phosphorylated MUS81 interacts with SLX4, and this association promotes the function of the MUS81 complex. In line with a role in mitosis, phosphorylation at Serine 87 is suppressed in S-phase and is mainly detected in the MUS81 molecules associated with EME1. Loss of CK2-dependent MUS81 phosphorylation contributes modestly to chromosome integrity, however, expression of the phosphomimic form induces DSBs accumulation in S-phase, because of unscheduled targeting of HJ-like DNA intermediates, and generates a wide chromosome instability phenotype. Collectively, our findings describe a novel regulatory mechanism controlling the MUS81 complex function in human cells. Furthermore, they indicate that, genome stability depends mainly on the ability of cells to counteract targeting of branched intermediates by the MUS81/EME1 complex in S-phase, rather than on a correct MUS81 function in mitosis.

  19. Rad54 and Mus81 cooperation promotes DNA damage repair and restrains chromosome missegregation

    DEFF Research Database (Denmark)

    Ghamrasni, S El; Cardoso, R; Li, L

    2016-01-01

    . The inefficient repair of DNA double-strand breaks (DSBs) in Rad54(-/-)Mus81(-/-) cells was accompanied by elevated levels of chromosome missegregation and cell death. Perhaps as a consequence, tumor incidence in Rad54(-/-)Mus81(-/-) mice remained comparable to that in Mus81(-/-) mice. Our study highlights...

  20. Le MusVerre, Sars-Poteries, Hauts-de-France

    OpenAIRE

    Schmitt , Daniel

    2017-01-01

    Le MusVerre, inauguré en 2016, présente une collection patrimoniale et contemporaine d'art verrier. Le scénario de la visite propose un parcours en deux temps avec une séquence historique : de l’histoire des « bousillés » à la création du musée avec une galerie technique qui donne un aperçu des gestes de l’art verrier. Puis une séquence contemporaine développe un panorama des collections d’art verrier d’aujourd’hui, dans leur grande richesse et originalité.

  1. INTEGRAL/JEM-X detection of fading emission from GT Mus

    DEFF Research Database (Denmark)

    Fiocchi, M.; Chenevez, J.; Sguera, V.

    2015-01-01

    On November 15th 2015 the MAXI/GSC detected a big flare from the RS CVn star GT Mus with a flux of ~100 mCrab in the 2-20 keV energy band. (ATel #8285). During recent INTEGRAL observations of the Musca region performed between 17 Nov 16:08 and 18 Nov 00:05 (UTC) the source GT Mus was within the f...

  2. Acute MUS81 depletion leads to replication fork slowing and a constitutive DNA damage response

    DEFF Research Database (Denmark)

    Xing, Meichun; Wang, Xiaohui; Palmai-Pallag, Timea

    2015-01-01

    have investigated the role of MUS81 in human cells by acutely depleting the protein using shRNAs. We found that MUS81 depletion from human fibroblasts leads to accumulation of ssDNA and a constitutive DNA damage response that ultimately activates cellular senescence. Moreover, we show that MUS81...

  3. Joint molecule resolution requires the redundant activities of MUS-81 and XPF-1 during Caenorhabditis elegans meiosis.

    Directory of Open Access Journals (Sweden)

    Nigel J O'Neil

    Full Text Available The generation and resolution of joint molecule recombination intermediates is required to ensure bipolar chromosome segregation during meiosis. During wild type meiosis in Caenorhabditis elegans, SPO-11-generated double stranded breaks are resolved to generate a single crossover per bivalent and the remaining recombination intermediates are resolved as noncrossovers. We discovered that early recombination intermediates are limited by the C. elegans BLM ortholog, HIM-6, and in the absence of HIM-6 by the structure specific endonuclease MUS-81. In the absence of both MUS-81 and HIM-6, recombination intermediates persist, leading to chromosome breakage at diakinesis and inviable embryos. MUS-81 has an additional role in resolving late recombination intermediates in C. elegans. mus-81 mutants exhibited reduced crossover recombination frequencies suggesting that MUS-81 is required to generate a subset of meiotic crossovers. Similarly, the Mus81-related endonuclease XPF-1 is also required for a subset of meiotic crossovers. Although C. elegans gen-1 mutants have no detectable meiotic defect either alone or in combination with him-6, mus-81 or xpf-1 mutations, mus-81;xpf-1 double mutants are synthetic lethal. While mus-81;xpf-1 double mutants are proficient for the processing of early recombination intermediates, they exhibit defects in the post-pachytene chromosome reorganization and the asymmetric disassembly of the synaptonemal complex, presumably triggered by crossovers or crossover precursors. Consistent with a defect in resolving late recombination intermediates, mus-81; xpf-1 diakinetic bivalents are aberrant with fine DNA bridges visible between two distinct DAPI staining bodies. We were able to suppress the aberrant bivalent phenotype by microinjection of activated human GEN1 protein, which can cleave Holliday junctions, suggesting that the DNA bridges in mus-81; xpf-1 diakinetic oocytes are unresolved Holliday junctions. We propose that the

  4. Control Of Motor Unit Firing During Step-Like Increases In Voluntary Force

    Directory of Open Access Journals (Sweden)

    Xiaogang eHu

    2014-09-01

    Full Text Available In most skeletal muscles, force is generated by a combination of motor unit (MU recruitment and increases in the firing rate of previously active MUs. Two contrasting patterns of firing rate organization have been reported. In the first pattern, the earliest recruited MUs reach the highest firing rates as force is increased, and later recruited MUs fire at lower rates. When firing rate of multiple MUs are superimposed, these rate trajectories form a concentric layered profile termed ‘onion skin’. In the second pattern, called ‘reverse onion skin’, later recruited MUs reach higher firing rates, and crossing of firing rate trajectories for recorded MUs is common (although such trajectories are assembled routinely from different trials. Our present study examined the firing rate organization of concurrently active MUs of the first dorsal interosseous muscle during serial, step-like increases in isometric abduction forces. We used a surface sensor array coupled with MU discrimination algorithms to characterize MU firing patterns. Our objective was to determine whether ‘onion skin’ profiles are contingent upon the force trajectory of the motor task, examined here using step-like increases of force output, and also whether they are manifested at different force levels.Our results revealed that the overall ‘onion skin’ firing rate profile was retained as the force level increased with each force step up to 15% MVC. However, the distribution of firing rates across MUs was compressed with increasing force, and overlapping firing rate of units were observed. This rate compression was largely due to rate saturation of the relatively high frequency discharging MUs.Our results reflect flexible firing patterns across MUs at different levels of excitation drive. It is also evident that many units did not follow all the step increases consistently. This failure to track firing rate increases at higher forces could be due to an intrinsically

  5. POSSuMUS: a position sensitive scintillating muon SiPM detector

    CERN Document Server

    Ruschke, Alexander

    The development of a modular designed large scale scintillation detector with a two-dimensional position sensitivity is presented in this thesis. This novel POsition Sensitive Scintillating MUon SiPM Detector is named POSSuMUS. The POSSuMUS detector is capable to determine the particle’s position in two space dimensions with a fast trigger capability. Each module is constructed from two trapezoidal shaped plastic scintillators to form one rectangular shaped detector module. Both trapezoids are optically insulated against each other. In both trapezoids the scintillation light is collected by plastic fibers and guided towards silicon photomultipliers (SiPMs). SiPMs are light sensors which are capable to detect even smallest amounts of light. By combining several detector modules, position sensitive areas from 100 cm2 to few m2 are achievable with few readout channels. Therefore, POSSuMUS provides a cost effective detector concept. The position sensitivity along the trapezoidal geometry of one detector module ...

  6. Les sens du musée

    Directory of Open Access Journals (Sweden)

    Laurent Grison

    1999-09-01

    Full Text Available Cet article, fondé sur l'exemple de la National Gallery de Londres, porte sur l'intégration dans le cadre urbain, l'aménagement et les dynamiques spatiales du lieu muséal. Sur le même thème, nous relatons un exercice réalisé avec des lycéens.

  7. Potential of MuS1 Transgenic Tobacco for Phytoremediation of the Urban Soils Contaminated with Cadmium

    Science.gov (United States)

    Kim, K. H.; Kim, Y. N.; Kim, S. H.

    2010-05-01

    Urban soils are prone to contamination by trace elements such as Cd, Cu, Pb and Zn. Phytoremediation is one of the attractive remediation methods for soils contaminated with trace elements due to its non-destructive and environmentally-friendly characteristic. Scientists have tried to find hyper-accumulator plants in nature or to develop transgenic plant through genetic engineering. This study was carried out to identify a potential of MuS1 transgenic tobacco for phytoremediation of the urban soils contaminated with Cd. MuS1 is known as a multiple stress related gene with several lines. The previous study using RT-PCR showed that the expression of MuS1 gene in tobacco plant induced tolerance to Cd stress. For this study, MuS1 transgenic tobacco and wild-type tobacco (control) were cultivated in a hydroponic system treated with Cd (0, 50, 100 and 200μM Cd) for 3 weeks. At harvest, both tobacco and nutrient solution were collected and were analyzed for Cd. Effect of Cd treatment on morphological change of the tobacco leaves was also observed by variable-pressure scanning electron microscopy (VP-SEM). The tolerance of MuS1 transgenic tobacco to Cd stress was better than that of wild-type tobacco at all Cd levels. Especially, wild-type tobacco showed chlorosis and withering with 200μM Cd treatment, whereas MuS1 transgenic tobacco gradually recovered from Cd damage. Wild-type tobacco accumulated more Cd (4.65mg per plant) than MuS1 transgenic tobacco (2.37mg per plant) with 200μM Cd treatment. Cd translocation rate from root to leaves was 81.8 % for wild-type tobacco compared to 37.1 % for MuS1 transgenic tobacco. Result of VP-SEM showed that the number of trichome in the leaves for wild-type tobacco increased in comparison with that for untreated samples after 3 weeks, while that for MuS1 transgenic tobacco was not changed by Cd treatment. Results showed that the mechanism of the recovery of the MuS1 tobacco plant was not by high level of Cd uptake and accumulation

  8. X-RAY DETECTION OF THE CLUSTER CONTAINING THE CEPHEID S MUS

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Karovska, Margarita; DePasquale, Joseph; Tingle, Evan [Smithsonian Astrophysical Observatory, MS 4, 60 Garden Street, Cambridge, MA 02138 (United States); Guinan, Edward; Engle, Scott [Department of Astronomy and Astrophysics, Villanova University, 800 Lancaster Avenue, Villanova, PA 19085 (United States); Bond, Howard E. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Schaefer, Gail H., E-mail: nevans@cfa.harvard.edu [The CHARA Array of Georgia State University, Mount Wilson, CA 91023 (United States)

    2014-04-20

    The galactic Cepheid S Muscae has recently been added to the important list of Cepheids linked to open clusters, in this case the sparse young cluster ASCC 69. Low-mass members of a young cluster are expected to have rapid rotation and X-ray activity, making X-ray emission an excellent way to discriminate them from old field stars. We have made an XMM-Newton observation centered on S Mus and identified a population of X-ray sources whose near-IR Two Micron All Sky Survey counterparts lie at locations in the J, (J – K) color-magnitude diagram consistent with cluster membership at the distance of S Mus. Their median energy and X-ray luminosity are consistent with young cluster members as distinct from field stars. These strengthen the association of S Mus with the young cluster, making it a potential Leavitt law (period-luminosity relation) calibrator.

  9. X-Ray Detection of the Cluster Containing the Cepheid S Mus

    Science.gov (United States)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Guinan, Edward; Engle, Scott; Bond, Howard E.; Schaefer, Gail H.; Karovska, Margarita; DePasquale, Joseph; Tingle, Evan

    2014-04-01

    The galactic Cepheid S Muscae has recently been added to the important list of Cepheids linked to open clusters, in this case the sparse young cluster ASCC 69. Low-mass members of a young cluster are expected to have rapid rotation and X-ray activity, making X-ray emission an excellent way to discriminate them from old field stars. We have made an XMM-Newton observation centered on S Mus and identified a population of X-ray sources whose near-IR Two Micron All Sky Survey counterparts lie at locations in the J, (J - K) color-magnitude diagram consistent with cluster membership at the distance of S Mus. Their median energy and X-ray luminosity are consistent with young cluster members as distinct from field stars. These strengthen the association of S Mus with the young cluster, making it a potential Leavitt law (period-luminosity relation) calibrator.

  10. X-RAY DETECTION OF THE CLUSTER CONTAINING THE CEPHEID S MUS

    International Nuclear Information System (INIS)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Karovska, Margarita; DePasquale, Joseph; Tingle, Evan; Guinan, Edward; Engle, Scott; Bond, Howard E.; Schaefer, Gail H.

    2014-01-01

    The galactic Cepheid S Muscae has recently been added to the important list of Cepheids linked to open clusters, in this case the sparse young cluster ASCC 69. Low-mass members of a young cluster are expected to have rapid rotation and X-ray activity, making X-ray emission an excellent way to discriminate them from old field stars. We have made an XMM-Newton observation centered on S Mus and identified a population of X-ray sources whose near-IR Two Micron All Sky Survey counterparts lie at locations in the J, (J – K) color-magnitude diagram consistent with cluster membership at the distance of S Mus. Their median energy and X-ray luminosity are consistent with young cluster members as distinct from field stars. These strengthen the association of S Mus with the young cluster, making it a potential Leavitt law (period-luminosity relation) calibrator

  11. MOTOR UNIT TERRITORIES AND FIBER TYPES IN RABBIT MASSETER MUSCLE

    NARCIS (Netherlands)

    WEIJS, WA; JUCH, PJW; KWA, SHS; KORFAGE, JAM

    1993-01-01

    The myosin heavy chain (MHC) content and spatial distribution of the fibers of 11 motor units (MUs) of the rabbit masseter muscle were determined. The fibers of single MUs were visualized in whole-muscle serial sections by a negative periodic acid/Schiff reaction for glycogen after they had been

  12. Dbf4-dependent kinase and the Rtt107 scaffold promote Mus81-Mms4 resolvase activation during mitosis.

    Science.gov (United States)

    Princz, Lissa N; Wild, Philipp; Bittmann, Julia; Aguado, F Javier; Blanco, Miguel G; Matos, Joao; Pfander, Boris

    2017-03-01

    DNA repair by homologous recombination is under stringent cell cycle control. This includes the last step of the reaction, disentanglement of DNA joint molecules (JMs). Previous work has established that JM resolving nucleases are activated specifically at the onset of mitosis. In case of budding yeast Mus81-Mms4, this cell cycle stage-specific activation is known to depend on phosphorylation by CDK and Cdc5 kinases. Here, we show that a third cell cycle kinase, Cdc7-Dbf4 (DDK), targets Mus81-Mms4 in conjunction with Cdc5-both kinases bind to as well as phosphorylate Mus81-Mms4 in an interdependent manner. Moreover, DDK-mediated phosphorylation of Mms4 is strictly required for Mus81 activation in mitosis, establishing DDK as a novel regulator of homologous recombination. The scaffold protein Rtt107, which binds the Mus81-Mms4 complex, interacts with Cdc7 and thereby targets DDK and Cdc5 to the complex enabling full Mus81 activation. Therefore, Mus81 activation in mitosis involves at least three cell cycle kinases, CDK, Cdc5 and DDK Furthermore, tethering of the kinases in a stable complex with Mus81 is critical for efficient JM resolution. © 2017 The Authors. Published under the terms of the CC BY NC ND 4.0 license.

  13. Motor units in the human medial gastrocnemius muscle are not spatially localized or functionally grouped.

    Science.gov (United States)

    Héroux, Martin E; Brown, Harrison J; Inglis, J Timothy; Siegmund, Gunter P; Blouin, Jean-Sébastien

    2015-08-15

    Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories or regions, with low-threshold units preferentially located distally. We used intramuscular recordings to measure the territory of muscle fibres from MG MUs and determine whether these MUs are grouped by recruitment threshold or joint action (ankle plantar flexion and knee flexion). The territory of MUs from the MG muscle varied from somewhat localized to highly distributed, with approximately half the MUs spanning at least half the length and width of the muscle. There was also no evidence of regional muscle activity based on MU recruitment thresholds or joint action. The CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories, with low-threshold units preferentially located distally. In this study, subjects (n = 8) performed ramped and sustained isometric contractions (ankle plantar flexion and knee flexion; range: ∼1-40% maximal voluntary contraction) and we measured MU territory size with spike-triggered averages from fine-wire electrodes inserted along the length (seven electrodes) or across the width (five electrodes) of the MG muscle. Of 69 MUs identified along the length of the muscle, 32 spanned at least half the muscle length (≥ 6.9 cm), 11 of which spanned all recording sites (13.6-17.9 cm). Distal fibres had smaller pennation angles (P recruitment threshold or contraction type, nor was there a relationship between MU territory size and recruitment threshold (Spearman's rho = -0.20 and 0.13, P > 0.18). MUs in the human MG have larger territories than previously reported and are not localized based on recruitment threshold or joint action. This indicates that the CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. © 2015 The Authors. The Journal of

  14. Unit Monitors Manchester-Format Data Buses

    Science.gov (United States)

    Amador, Jose J.

    1994-01-01

    Circuit card converts data signals into convenient hexadecimal form for troubleshooting. Bus-monitoring unit converts data signals from Manchester II format used on data bus into hexadecimal format. Monitoring circuit causes hexadecimal words to display on video terminal, where test engineer compares them with hexadecimal records for troubleshooting. Circuit monitors one bus or two buses simultaneously.

  15. Disruption of SLX4-MUS81 Function Increases the Relative Biological Effectiveness of Proton Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qi [Laboratory of Cellular and Molecular Radiation Oncology, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Underwood, Tracy S.A.; Kung, Jong [Division of Radiation Physics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Wang, Meng [Laboratory of Cellular and Molecular Radiation Oncology, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Lu, Hsiao-Ming; Paganetti, Harald [Division of Radiation Physics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Held, Kathryn D.; Hong, Theodore S.; Efstathiou, Jason A. [Laboratory of Cellular and Molecular Radiation Oncology, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Willers, Henning, E-mail: hwillers@mgh.harvard.edu [Laboratory of Cellular and Molecular Radiation Oncology, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2016-05-01

    Purpose: Clinical proton beam therapy has been based on the use of a generic relative biological effectiveness (RBE) of ∼1.1. However, emerging data have suggested that Fanconi anemia (FA) and homologous recombination pathway defects can lead to a variable RBE, at least in vitro. We investigated the role of SLX4 (FANCP), which acts as a docking platform for the assembly of multiple structure-specific endonucleases, in the response to proton irradiation. Methods and Materials: Isogenic cell pairs for the study of SLX4, XPF/ERCC1, MUS81, and SLX1 were irradiated at the mid-spread-out Bragg peak of a clinical proton beam (linear energy transfer 2.5 keV/μm) or with 250 kVp x-rays, and the clonogenic survival fractions were determined. To estimate the RBE of the protons relative to cobalt-60 photons (Co60Eq), we assigned a RBE(Co60Eq) of 1.1 to x-rays to correct the physical dose measured. Standard DNA repair foci assays were used to monitor the damage responses, and the cell cycle distributions were assessed by flow cytometry. The poly(ADP-ribose) polymerase inhibitor olaparib was used for comparison. Results: Loss of SLX4 function resulted in an enhanced proton RBE(Co60Eq) of 1.42 compared with 1.11 for wild-type cells (at a survival fraction of 0.1; P<.05), which correlated with increased persistent DNA double-strand breaks in cells in the S/G{sub 2} phase. Genetic analysis identified the SLX4-binding partner MUS81 as a mediator of resistance to proton radiation. Both proton irradiation and olaparib treatment resulted in a similar prolonged accumulation of RAD51 foci in SLX4/MUS81-deficient cells, suggesting a common defect in the repair of DNA replication fork-associated damage. Conclusions: A defect in the FA pathway at the level of SLX4 results in hypersensitivity to proton radiation, which is, at least in part, due to impaired MUS81-mediated processing of replication forks that stall at clustered DNA damage. In vivo and clinical studies are needed to

  16. Independent verification of monitor unit calculation for radiation treatment planning system.

    Science.gov (United States)

    Chen, Li; Chen, Li-Xin; Huang, Shao-Min; Sun, Wen-Zhao; Sun, Hong-Qiang; Deng, Xiao-Wu

    2010-02-01

    To ensure the accuracy of dose calculation for radiation treatment plans is an important part of quality assurance (QA) procedures for radiotherapy. This study evaluated the Monitor Units (MU) calculation accuracy of a third-party QA software and a 3-dimensional treatment planning system (3D TPS), to investigate the feasibility and reliability of independent verification for radiation treatment planning. Test plans in a homogenous phantom were designed with 3-D TPS, according to the International Atomic Energy Agency (IAEA) Technical Report No. 430, including open, blocked, wedge, and multileaf collimator (MLC) fields. Test plans were delivered and measured in the phantom. The delivered doses were input to the QA software and the independent calculated MUs were compared with delivery. All test plans were verified with independent calculation and phantom measurements separately, and the differences of the two kinds of verification were then compared. The deviation of the independent calculation to the measurements was (0.1 +/- 0.9)%, the biggest difference fell onto the plans that used block and wedge fields (2.0%). The mean MU difference between the TPS and the QA software was (0.6 +/- 1.0)%, ranging from -0.8% to 2.8%. The deviation in dose of the TPS calculation compared to the measurements was (-0.2 +/- 1.7)%, ranging from -3.9% to 2.9%. MU accuracy of the third-party QA software is clinically acceptable. Similar results were achieved with the independent calculations and the phantom measurements for all test plans. The tested independent calculation software can be used as an efficient tool for TPS plan verification.

  17. Changes in contractile properties and action potentials of motor units in the rat medial gastrocnemius muscle during maturation.

    Science.gov (United States)

    Dobrzynska, Z; Celichowski, J

    2016-02-01

    The early phase of development of muscles stops following the disappearance of embryonic and neonatal myosin and the elimination of polyneuronal innervation of muscle fibres with the formation of motor units (MUs), but later the muscle mass still considerably increases. It is unknown whether the three types are visible among newly formed MUs soon after the early postnatal period and whether their proportion is similar to that in adult muscle. Moreover, the processes responsible for MU-force regulation by changes in motoneuronal firing rate as well as properties of motor unit action potentials (MUAPs) during maturation are unknown. Three groups of Wistar rats were investigated - 1 month old, 2 months old and the adult, 9 months old. The basic contractile properties and action potentials of MUs in the medial gastrocnemius (MG) muscle were analysed. The three types of MUs were distinguishable in all age groups, but higher proportion of slow MUs was noticed in young rats (29%, 18% and 11% in 1, 2 and 9 months rats, respectively). The fatigue index for fast fatigable MUs in 1 month old rats was about 2 times higher than in 9 months old rats. The twitch time parameters of fast MUs were shortened during the maturation; for these units, the force-frequency curves in young rats were shifted towards lower frequencies, which suggested that fast motoneurons of young animals generate lower firing rates. Higher twitch-to-tetanus ratios noted for the three MU types in young rats suggested the smaller role of rate coding in force regulation processes, and the higher role of MU recruitment in young rats. No significant differences in MUAP parameters between two groups of young and adult animals were observed. Concluding, the maturation process evokes deeper changes in fast MUs than in slow ones.

  18. Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Sudahar, H.; Kurup, P.G.G.; Murali, V.; Velmurugan, J.

    2012-01-01

    Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuracy Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%. (author)

  19. POSSuMUS. A position sensitive scintillating muon SiPM detector

    International Nuclear Information System (INIS)

    Ruschke, Alexander

    2014-01-01

    The development of a modular designed large scale scintillation detector with a two-dimensional position sensitivity is presented in this thesis. This novel POsition Sensitive Scintillating MUon SiPM Detector is named POSSuMUS. The POSSuMUS detector is capable to determine the particle's position in two space dimensions with a fast trigger capability. Each module is constructed from two trapezoidal shaped plastic scintillators to form one rectangular shaped detector module. Both trapezoids are optically insulated against each other. In both trapezoids the scintillation light is collected by plastic fibers and guided towards silicon photomultipliers (SiPMs). SiPMs are light sensors which are capable to detect even smallest amounts of light. By combining several detector modules, position sensitive areas from 100 cm 2 to few m 2 are achievable with few readout channels. Therefore, POSSuMUS provides a cost effective detector concept. The position sensitivity along the trapezoidal geometry of one detector module is achieved by the path length dependent amount of detected light for crossing particles. The ratio of the light yields in both trapezoids is calculated. This value corresponds to the position of the particle traversing the detector. A spatial resolution in the order of several mm is foreseen. The position sensitivity along the scintillator module is determined by the propagation time of light to the SiPMs located on opposite sides of the detector. A spatial resolution of few cm is expected for this direction. The POSSuMUS detector is applicable as large area trigger detector with a two dimensional position information of crossing particles. This is suitable in detector tests of large area precesion detectors or for measuring the small angle scattering of cosmic muons. At the beginning of this thesis, the determination of important SiPM characteristics like the breakdown voltage is presented. In the course of this work the detector principle is proven by

  20. Population biology of house mice (Mus musculus L.) on sub ...

    African Journals Online (AJOL)

    1993-05-03

    May 3, 1993 ... Studies on the feral house mouse Mus musculus in habitats ranging from deserts ... Previous studies on mice at Marion Island focused on ..... and food availability) may decrease the rate of development .... Wiley, New York.

  1. Host subspecific viral strains in European house mice: Murine cytomegalovirus in the Eastern (Mus musculus musculus) and Western house mouse (Mus musculus domesticus).

    Science.gov (United States)

    Čížková, Dagmar; Baird, Stuart J E; Těšíková, Jana; Voigt, Sebastian; Ľudovít, Ďureje; Piálek, Jaroslav; Goüy de Bellocq, Joëlle

    2018-06-09

    Murine cytomegalovirus (MCMV) has been reported from house mice (Mus musculus) worldwide, but only recently from Eastern house mice (M. m. musculus), of particular interest because they form a semi-permeable species barrier in Europe with Western house mice, M. m. domesticus. Here we report genome sequences of EastMCMV (from Eastern mice), and set these in the context of MCMV genomes from genus Mus hosts. We show EastMCMV and WestMCMV are genetically distinct. Phylogeny splitting analyses show a genome wide (94%) pattern consistent with no West-East introgression, the major exception (3.8%) being a genome-terminal region of duplicated genes involved in host immune system evasion. As expected from its function, this is a region of maintenance of ancestral polymorphism: The lack of clear splitting signal cannot be interpreted as evidence of introgression. The EastMCMV genome sequences reported here can therefore serve as a well-described resource for exploration of murid MCMV diversity. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Nova Mus 2018 (PNV J11261220-6531086) Is Forming Dust

    Science.gov (United States)

    Walter, Frederick M.

    2018-02-01

    Nova Mus 2018 (PNV J11261220-6531086) was discovered by R Kaufman on 2018 Jan 14.486, and reported by P. Schmeer in vsnet-alert 21772. The first detection was 2018 Jan 3.24 (ASAS-SN, reported in the TOCP).

  3. Jaguar surveying and monitoring in the United States

    Science.gov (United States)

    Culver, Melanie

    2016-06-10

    Because of the jaguar’s (Panthera onca) endangered status under the Endangered Species Act (ESA) of 1973 throughout its range (from Arizona in the north to Argentina in the south), jaguar individuals and populations are monitored to varying degrees throughout their range. Knowledge gained from monitoring jaguars is helpful for wildlife managers who are responsible for conserving this species. The University of Arizona (UA) has conducted a multiyear surveying and monitoring effort for jaguars and ocelots in southern Arizona and New Mexico. The purpose of this work was to establish an effective surveying and monitoring system for jaguars along the United States-Mexico border. Surveying and monitoring in this study focused on the United States side of the border, but the methods could also be used in Mexico. The intent was to develop and implement a surveying and monitoring system that would provide the greatest probability of recording jaguar presence in, and passage through, the border area.

  4. Contractile properties of motor units and expression of myosin heavy chain isoforms in rat fast-type muscle after volitional weight-lifting training.

    Science.gov (United States)

    Łochyński, Dawid; Kaczmarek, Dominik; Mrówczyński, Włodzimierz; Warchoł, Wojciech; Majerczak, Joanna; Karasiński, Janusz; Korostyński, Michał; Zoladz, Jerzy A; Celichowski, Jan

    2016-10-01

    Dynamic resistance training increases the force and speed of muscle contraction, but little is known about modifications to the contractile properties of the main physiological types of motor units (MUs) that contribute to these muscle adaptations. Although the contractile profile of MU muscle fibers is tightly coupled to myosin heavy chain (MyHC) protein expression, it is not well understood if MyHC transition is a prerequisite for modifications to the contractile characteristics of MUs. In this study, we examined MU contractile properties, the mRNA expression of MyHC, parvalbumin, and sarcoendoplasmic reticulum Ca 2+ pump isoforms, as well as the MyHC protein content after 5 wk of volitional progressive weight-lifting training in the medial gastrocnemius muscle in rats. The training had no effect on MyHC profiling or Ca 2+ -handling protein gene expression. Maximum force increased in slow (by 49%) and fast (by 21%) MUs. Within fast MUs, the maximum force increased in most fatigue-resistant and intermediate but not most fatigable MUs. Twitch contraction time was shortened in slow and fast fatigue-resistant MUs. Twitch half-relaxation was shortened in fast most fatigue-resistant and intermediate MUs. The force-frequency curve shifted rightward in fast fatigue-resistant MUs. Fast fatigable MUs fatigued less within the initial 15 s while fast fatigue-resistant units increased the ability to potentiate the force within the first minute of the standard fatigue test. In conclusion, at the early stage of resistance training, modifications to the contractile characteristics of MUs appear in the absence of MyHC transition and the upregulation of Ca 2+ -handling genes. Copyright © 2016 the American Physiological Society.

  5. An Approach for Simulation of the Muscle Force Modeling It by Summation of Motor Unit Contraction Forces

    Directory of Open Access Journals (Sweden)

    Rositsa Raikova

    2013-01-01

    Full Text Available Muscle force is due to the cumulative effect of repetitively contracting motor units (MUs. To simulate the contribution of each MU to whole muscle force, an approach implemented in a novel computer program is proposed. The individual contraction of an MU (the twitch is modeled by a 6-parameter analytical function previously proposed; the force of one MU is a sum of its contractions due to an applied stimulation pattern, and the muscle force is the sum of the active MUs. The number of MUs, the number of slow, fast-fatigue-resistant, and fast-fatigable MUs, and their six parameters as well as a file with stimulation patterns for each MU are inputs for the developed software. Different muscles and different firing patterns can be simulated changing the input data. The functionality of the program is illustrated with a model consisting of 30 MUs of rat medial gastrocnemius muscle. The twitches of these MUs were experimentally measured and modeled. The forces of the MUs and of the whole muscle were simulated using different stimulation patterns that included different regular, irregular, synchronous, and asynchronous firing patterns of MUs. The size principle of MUs for recruitment and derecruitment was also demonstrated using different stimulation paradigms.

  6. Mitochondrial DNA in the hybrid zone between Mus musculus musculus and Mus musculus domesticus: a comparison of two transects

    Czech Academy of Sciences Publication Activity Database

    Božíková, Eva; Munclinger, P.; Teeter, K. C.; Tucker, P. K.; Macholán, Miloš; Piálek, Jaroslav

    2005-01-01

    Roč. 84, č. 3 (2005), s. 363-378 ISSN 0024-4066. [The genus Mus as a model for evolutionary studies - a symposium in honour of Louis Thaler. Brno, 28.07.2003-30.07.2003] R&D Projects: GA ČR GA206/03/0205; GA ČR GA206/01/0989 Institutional research plan: CEZ:AV0Z6093917 Keywords : allozyme * gene flow * house mouse Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.261, year: 2005

  7. Covert video monitoring in the assessment of medically unexplained symptoms in children.

    Science.gov (United States)

    Wallace, Dustin P; Sim, Leslie A; Harrison, Tracy E; Bruce, Barbara K; Harbeck-Weber, Cynthia

    2012-04-01

    Diagnosis of medically unexplained symptoms (MUS) occurs after thorough evaluations have failed to identify a physiological cause for symptoms. However, families and providers may wonder if something has been missed, leading to reduced confidence in behavioral treatment. Confidence may be improved through the use of technology such as covert video monitoring to better assess functioning across settings. A 12-year-old male presented with progressive neurological decline, precipitated by chronic pain. After thorough evaluation and the failure of standard treatments (medical, rehabilitative, and psychological) covert video monitoring revealed that the patient demonstrated greater abilities when alone in his room. Negative reinforcement was used to initiate recovery, accompanied by positive reinforcement and a rehabilitative approach. Covert video monitoring assisted in three subsequent cases over the following 3 years. In certain complex cases, video monitoring can inform the assessment and treatment of MUS. Discussion includes ethical and practical considerations.

  8. Stop Stalling: Mus81 Required for Efficient Replication | Center for Cancer Research

    Science.gov (United States)

    DNA replication is precisely controlled to ensure that daughter cells receive intact, accurate genetic information. Each segment of DNA must be copied only once, and the rate of replication coordinated genome-wide. Mild replication stress slows DNA synthesis and activates a pathway involving the Mus81 endonuclease, which generates a series of DNA breaks that are rapidly repaired, allowing the cell to avoid activating the S-phase checkpoint and its potentially damaging outcomes of apoptosis or error-prone repair. Mirit Aladjem, Ph.D., of CCR’s Developmental Therapeutics Branch, and her colleagues wondered whether Mus81 also plays a role in regulating the replication rate during growth in the absence of stress.

  9. RECQ5 Helicase Cooperates with MUS81 Endonuclease in Processing Stalled Replication Forks at Common Fragile Sites during Mitosis

    DEFF Research Database (Denmark)

    Di Marco, Stefano; Hasanova, Zdenka; Kanagaraj, Radhakrishnan

    2017-01-01

    The MUS81-EME1 endonuclease cleaves late replication intermediates at common fragile sites (CFSs) during early mitosis to trigger DNA-repair synthesis that ensures faithful chromosome segregation. Here, we show that these DNA transactions are promoted by RECQ5 DNA helicase in a manner dependent...... on its Ser727 phosphorylation by CDK1. Upon replication stress, RECQ5 associates with CFSs in early mitosis through its physical interaction with MUS81 and promotes MUS81-dependent mitotic DNA synthesis. RECQ5 depletion or mutational inactivation of its ATP-binding site, RAD51-interacting domain...

  10. Comparison of monitor units calculated by radiotherapy treatment planning system and an independent monitor unit verification software.

    Science.gov (United States)

    Sellakumar, P; Arun, C; Sanjay, S S; Ramesh, S B

    2011-01-01

    In radiation therapy, the monitor units (MU) needed to deliver a treatment plan are calculated by treatment planning systems (TPS). The essential part of quality assurance is to verify the MU with independent monitor unit calculation to correct any potential errors prior to the start of treatment. In this study, we have compared the MU calculated by TPS and by independent MU verification software. The MU verification software was commissioned and tested for the data integrity to ensure that the correct beam data was considered for MU calculations. The accuracy of the calculations was tested by creating a series of test plans and comparing them with ion chamber measurements. The results show that there is good agreement between the two. The MU difference (MUdiff) between the monitor unit calculations of TPS and independent MU verification system was calculated for 623 fields from 245 patients and was analyzed by treatment site for head & neck, thorax, breast, abdomen and pelvis. The mean MUdiff of -0.838% with a standard deviation of 3.04% was observed for all 623 fields. The site specific standard deviation of MUdiff was as follows: abdomen and pelvis (<1.75%), head & neck (2.5%), thorax (2.32%) and breast (6.01%). The disparities were analyzed and different correction methods were used to reduce the disparity. © 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. X-ray and UV observations of Nova Mus 2018 with Swift

    Science.gov (United States)

    Nelson, Thomas; Mukai, Koji; Chomiuk, Laura; Li, Kwan-Kok; Kawash, Adam; Sokoloski, J. L.; Rupen, Michael; Linford, Justin; Mioduszewski, Amy

    2018-01-01

    We observed Nova Mus 2018 (PNV J11261220-6531086) with the Neil Gehrels Swift Observatory on 2018 January 21, 18 days after the initial rapid rise to V=8.8 on 2018 January 3.24 (see link below for more details).

  12. Meiosis and speciation: a study in a speciating Mus terricolor complex

    Indian Academy of Sciences (India)

    Unknown

    2000-12-27

    Dec 27, 2000 ... (see reviews by White 1978; King 1981) or would lead to reduced viability of ... Indian pygmy field mice Mus terricolor, vis-à-vis the fixa- tion of autosomal ... plexes (SCs) were prepared and stained with silver nitrate. (Fletcher ...

  13. Effects of whole body vibration on motor unit recruitment and threshold.

    Science.gov (United States)

    Pollock, Ross D; Woledge, Roger C; Martin, Finbarr C; Newham, Di J

    2012-02-01

    Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition.

  14. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem

    OpenAIRE

    Muller , Antoine; Pontonnier , Charles; Dumont , Georges

    2018-01-01

    International audience; The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions – two polynomial criteria and a min/max criterion – were tested on a planar musculoskeletal model. The MusIC method provides a computation frequenc...

  15. Comparison of ghosting effects for three commercial a-Si EPIDs

    International Nuclear Information System (INIS)

    McDermott, L. N.; Nijsten, S. M. J. J. G.; Sonke, J.-J.; Partridge, M.; Herk, M. van; Mijnheer, B. J.

    2006-01-01

    Many studies have reported dosimetric characteristics of amorphous silicon electronic portal imaging devices (EPIDs). Some studies ascribed a non-linear signal to gain ghosting and image lag. Other reports, however, state the effect is negligible. This study compares the signal-to-monitor unit (MU) ratio for three different brands of EPID systems. The signal was measured for a wide range of monitor units (5-1000), dose-rates, and beam energies. All EPIDs exhibited a relative under-response for beams of few MUs; giving 4 to 10% lower signal-to-MU ratios relative to that of 1000 MUs. This under-response is consistent with ghosting effects due to charge trapping

  16. Musée ideale : unistused täiuslikust muuseumist / Mariann Raisma

    Index Scriptorium Estoniae

    Raisma, Mariann, 1974-

    2008-01-01

    18.-19. sajandi unistusi täiuslikust muuseumist kolmel tasandil: vormi ehk arhitektuuri, muuseumikogu terviklikkuse ning pärandi kättesaadavuse kaudu. Pikemalt Napoleon Bonaparte'ile pühendatud Musée Napoleoni kogudest, kontseptsioonist ja koopiamuuseumidest Lääne-Euroopas ning Tartus

  17. Infrared and optical observations of Nova Mus 1983

    International Nuclear Information System (INIS)

    Whitelock, P.A.; Carter, B.S.; Feast, M.W.; Glass, I.S.; Laney, D.; Menzies, J.W.

    1984-01-01

    Extensive optical (UBVRI) and infrared (JHKL) photometry of Nova Mus 1983 obtained over a period of 300 days is tabulated. Infrared and optical spectra are described. Although by classical definition this was a fast nova its later development was slower than for typical objects of this class. Surprisingly the development of infrared thermal dust emission did not occur. Throughout the period covered, the infrared emission was characteristic of a bound-free plus free-free plasma continuum with emission lines. (author)

  18. Automatic Flushing Unit With Cleanliness Monitor

    Science.gov (United States)

    Hildebrandt, N. E.

    1982-01-01

    Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.

  19. A machine learning approach to the accurate prediction of monitor units for a compact proton machine.

    Science.gov (United States)

    Sun, Baozhou; Lam, Dao; Yang, Deshan; Grantham, Kevin; Zhang, Tiezhi; Mutic, Sasa; Zhao, Tianyu

    2018-05-01

    Clinical treatment planning systems for proton therapy currently do not calculate monitor units (MUs) in passive scatter proton therapy due to the complexity of the beam delivery systems. Physical phantom measurements are commonly employed to determine the field-specific output factors (OFs) but are often subject to limited machine time, measurement uncertainties and intensive labor. In this study, a machine learning-based approach was developed to predict output (cGy/MU) and derive MUs, incorporating the dependencies on gantry angle and field size for a single-room proton therapy system. The goal of this study was to develop a secondary check tool for OF measurements and eventually eliminate patient-specific OF measurements. The OFs of 1754 fields previously measured in a water phantom with calibrated ionization chambers and electrometers for patient-specific fields with various range and modulation width combinations for 23 options were included in this study. The training data sets for machine learning models in three different methods (Random Forest, XGBoost and Cubist) included 1431 (~81%) OFs. Ten-fold cross-validation was used to prevent "overfitting" and to validate each model. The remaining 323 (~19%) OFs were used to test the trained models. The difference between the measured and predicted values from machine learning models was analyzed. Model prediction accuracy was also compared with that of the semi-empirical model developed by Kooy (Phys. Med. Biol. 50, 2005). Additionally, gantry angle dependence of OFs was measured for three groups of options categorized on the selection of the second scatters. Field size dependence of OFs was investigated for the measurements with and without patient-specific apertures. All three machine learning methods showed higher accuracy than the semi-empirical model which shows considerably large discrepancy of up to 7.7% for the treatment fields with full range and full modulation width. The Cubist-based solution

  20. On the hazard rate process for imperfectly monitored multi-unit systems

    International Nuclear Information System (INIS)

    Barros, A.; Berenguer, C.; Grall, A.

    2005-01-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies

  1. On the hazard rate process for imperfectly monitored multi-unit systems

    Energy Technology Data Exchange (ETDEWEB)

    Barros, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)]. E-mail: anne.barros@utt.fr; Berenguer, C. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France); Grall, A. [Institut des Sciences et Techonologies de l' Information de Troyes (ISTIT-CNRS), Equipe de Modelisation et Surete des Systemes, Universite de Technologie de Troyes (UTT), 12, rue Marie Curie, BP2060, 10010 Troyes cedex (France)

    2005-12-01

    The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies.

  2. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem.

    Science.gov (United States)

    Muller, A; Pontonnier, C; Dumont, G

    2018-02-01

    The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions - two polynomial criteria and a min/max criterion - were tested on a planar musculoskeletal model. The MusIC method provides a computation frequency approximately 10 times higher compared to a classical optimization problem with a relative mean error of 4% on cost function evaluation.

  3. Localised task-dependent motor-unit recruitment in the masseter.

    Science.gov (United States)

    Schindler, H J; Hellmann, D; Giannakopoulos, N N; Eiglsperger, U; van Dijk, J P; Lapatki, B G

    2014-07-01

    Localised motor-unit (MU) recruitment in the masseter was analysed in this study. We investigated whether differential activation behaviour, which has already been reported for distant masseter regions, can also be detected in small muscle subvolumes at the level of single MUs. Two bipolar fine-wire electrodes and an intra-oral 3D bite-force transmitter were used to record intra-muscular electromyograms (EMG) resulting from controlled bite-forces of 10 healthy human subjects (mean age 24.1 ± 1.2 years). Two-hundred and seventeen decomposed MUs were organised into localised MU task groups with different (P < 0.001) force-direction-specific behaviour. Proportions of MUs involved in one, two, three or four examined tasks were 46%, 31%, 18% and 5%, respectively. This study provides evidence of the ability of the neuromuscular system to modify the mechanical output of small masseter subvolumes by differential control of adjacent MUs belonging to distinct task groups. Localised differential activation behaviour of the masseter may be the crucial factor enabling highly flexible and efficient adjustment of the muscle activity in response to complex local biomechanical needs, for example, continually varying bite-forces during the demanding masticatory process. © 2014 John Wiley & Sons Ltd.

  4. PEMANFAATAN Spirulina platensis SEBAGAI SUPLEMEN PROTEIN SEL TUNGGAL (PST MENCIT (Mus musculus

    Directory of Open Access Journals (Sweden)

    Haryo Kuntoro Adi

    2007-06-01

    Full Text Available The using of Spirulina platensis as Supplement of Single-Celled Protein (SCP to Mice. High protein in Spirulina platensis can be used as a source of Single-Celled Protein. By using mice (Mus musculus as a animal laboratory, the objective of this research is to know the influence of Biomass S. platensis to the increase of body weight of mice. The name of species is Mus musculus, strain is Swiss derivate. Utilized mice were male, 30-50 weighing gram, and 5-7 weeks of age. Treatment group was given by palette and given by biomass of S. Platensis, while control also fed palette but did not give biomass of S. platensis. Yielded biomass was used as food mixed with palette with composition of dry biomass S. platensis with palette was 0%, 10%, 20%, 30%, 40%, and 50%. Data analysis was conducted by using t-tes and analysis of variance. The results showed that by giving of dry biomass of S. platensis affected to the increasement of body weight from the first day until twelfth day of observation, and decrease on the thirteenth and fourteenth day. Pursuant to result of statistic, there is a significant difference (p < 0,05 between before giving and after giving of dry biomass S. platensis during 17 day. By giving dry biomass of S. platensis to mice (Mus musculus at first and second week, it was found the difference of average mice body weight among six concentrations of biomass but did not at the third week. It means that not all concentration of biomass have same effect to the increase of mice body weight as a Single-Celled Protein.

  5. Sleep/wake firing patterns of human genioglossus motor units.

    Science.gov (United States)

    Bailey, E Fiona; Fridel, Keith W; Rice, Amber D

    2007-12-01

    Although studies of the principal tongue protrudor muscle genioglossus (GG) suggest that whole muscle GG electromyographic (EMG) activities are preserved in nonrapid eye movement (NREM) sleep, it is unclear what influence sleep exerts on individual GG motor unit (MU) activities. We characterized the firing patterns of human GG MUs in wakefulness and NREM sleep with the aim of determining 1) whether the range of MU discharge patterns evident in wakefulness is preserved in sleep and 2) what effect the removal of the "wakefulness" input has on the magnitude of the respiratory modulation of MU activities. Microelectrodes inserted into the extrinsic tongue protrudor muscle, the genioglossus, were used to follow the discharge of single MUs. We categorized MU activities on the basis of the temporal relationship between the spike train and the respiration cycle and quantified the magnitude of the respiratory modulation of each MU using the eta (eta(2)) index, in wakefulness and sleep. The majority of MUs exhibited subtle increases or decreases in respiratory modulation but were otherwise unaffected by NREM sleep. In contrast, 30% of MUs exhibited marked sleep-associated changes in discharge frequency and respiratory modulation. We suggest that GG MUs should not be considered exclusively tonic or phasic; rather, the discharge pattern appears to be a flexible feature of GG activities in healthy young adults. Whether such flexibility is important in the response to changes in the chemical and/or mechanical environment and whether it is preserved as a function of aging or in individuals with obstructive sleep apnea are critical questions for future research.

  6. Corrected placement of Mus-Rattus fossil calibration forces precision in the molecular tree of rodents.

    Science.gov (United States)

    Kimura, Yuri; Hawkins, Melissa T R; McDonough, Molly M; Jacobs, Louis L; Flynn, Lawrence J

    2015-09-28

    Time calibration derived from the fossil record is essential for molecular phylogenetic and evolutionary studies. Fossil mice and rats, discovered in the Siwalik Group of Pakistan, have served as one of the best-known fossil calibration points in molecular phylogenic studies. Although these fossils have been widely used as the 12 Ma date for the Mus/Rattus split or a more basal split, conclusive paleontological evidence for the nodal assignments has been absent. This study analyzes newly recognized characters that demonstrate lineage separation in the fossil record of Siwalik murines and examines the most reasonable nodal placement of the diverging lineages in a molecular phylogenetic tree by ancestral state reconstruction. Our specimen-based approach strongly indicates that Siwalik murines of the Karnimata clade are fossil members of the Arvicanthini-Otomyini-Millardini clade, which excludes Rattus and its relatives. Combining the new interpretation with the widely accepted hypothesis that the Progonomys clade includes Mus, the lineage separation event in the Siwalik fossil record represents the Mus/Arvicanthis split. Our test analysis on Bayesian age estimates shows that this new calibration point provides more accurate estimates of murine divergence than previous applications. Thus, we define this fossil calibration point and refine two other fossil-based points for molecular dating.

  7. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.

    Science.gov (United States)

    McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George

    2016-07-01

    The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.

  8. Monitoring water for radioactive releases in the United States

    International Nuclear Information System (INIS)

    Porter, C.R.; Broadway, J.A.; Kahn, B.

    1990-01-01

    The major radiological environmental monitoring programs for water in the United States are described. The applications of these programs for monitoring radioactive fallout, routine discharges from nuclear facilities, and releases due to accidents at such facilities are discussed, and some examples of measurements are presented. The programs monitor rainfall, surface water, and water supplies. Samples are usually collected and analyzed on a monthly or quarterly schedule, but the frequency is increased in response to emergencies. (author)

  9. Results of a 10-year survey of workload for 10 treatment vaults at a high-throughput comprehensive cancer center.

    Science.gov (United States)

    Saleh, Ziad H; Jeong, Jeho; Quinn, Brian; Mechalakos, James; St Germain, Jean; Dauer, Lawrence T

    2017-05-01

    The workload for shielding purposes of modern linear accelerators (linacs) consists of primary and scatter radiation which depends on the dose delivered to isocenter (cGy) and leakage radiation which depends on the monitor units (MUs). In this study, we report on the workload for 10 treatment vaults in terms of dose to isocenter (cGy), monitor units delivered (MUs), number of treatment sessions (Txs), as well as, use factors (U) and modulation factors (CI) for different treatment techniques. The survey was performed for the years between 2006 and 2015 and included 16 treatment machines which represent different generations of Varian linear accelerators (6EX, 600C, 2100C, 2100EX, and TrueBeam) operating at different electron and x-ray energies (6, 9, 12, 16 and 20 MeV electrons and, 6 and 15 MV x-rays). An institutional review board (IRB) approval was acquired to perform this study. Data regarding patient workload, dose to isocenter, number of monitor units delivered, beam energies, gantry angles, and treatment techniques were exported from an ARIA treatment management system (Varian Medical Systems, Palo Alto, Ca.) into Excel spreadsheets and data analysis was performed in Matlab. The average (± std-dev) number of treatment sessions, dose to isocenter, and number of monitor units delivered per week per machine in 2006 was 119 ± 39 Txs, (300 ± 116) × 10 2 cGys, and (78 ± 28) × 10 3 MUs respectively. In contrast, the workload in 2015 was 112 ± 40 Txs, (337 ± 124) × 10 2 cGys, and (111 ± 46) × 10 3 MUs. 60% of the workload (cGy) was delivered using 6 MV and 30% using 15 MV while the remaining 10% was delivered using electron beams. The modulation factors (MU/cGy) for IMRT and VMAT were 5.0 (± 3.4) and 4.6 (± 1.6) respectively. Use factors using 90° gantry angle intervals were equally distributed (~0.25) but varied considerably among different treatment techniques. The workload, in terms of dose to isocenter (cGy) and subsequently monitor units (MUs), has

  10. The role of salivary androgen-binding protein in reproductive isolation between two subspecies of house mouse: Mus musculus musculus and Mus musculus domesticus

    Czech Academy of Sciences Publication Activity Database

    Bímová, Barbora; Karn, R. C.; Piálek, Jaroslav

    2005-01-01

    Roč. 84, č. 3 (2005), s. 349-361 ISSN 0024-4066. [The genus Mus as a model for evolutionary studies - a symposium in honour of Louis Thaler. Brno, 28.07.2003-30.07.2003] R&D Projects: GA AV ČR IAA6093201; GA AV ČR IAA6045902 Grant - others:National Research Council(US) COBASE Institutional research plan: CEZ:AV0Z6093917 Keywords : assortative mating * hybrid zone * sexual selection Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.261, year: 2005

  11. Independent monitor unit calculation for intensity modulated radiotherapy using the MIMiC multileaf collimator

    International Nuclear Information System (INIS)

    Chen Zhe; Xing Lei; Nath, Ravinder

    2002-01-01

    A self-consistent monitor unit (MU) and isocenter point-dose calculation method has been developed that provides an independent verification of the MU for intensity modulated radiotherapy (IMRT) using the MIMiC (Nomos Corporation) multileaf collimator. The method takes into account two unique features of IMRT using the MIMiC: namely the gantry-dynamic arc delivery of intensity modulated photon beams and the slice-by-slice dose delivery for large tumor volumes. The method converts the nonuniform beam intensity planned at discrete gantry angles of 5 deg. or 10 deg. into conventional nonmodulated beam intensity apertures of elemental arc segments of 1 deg. This approach more closely simulates the actual gantry-dynamic arc delivery by MIMiC. Because each elemental arc segment is of uniform intensity, the MU calculation for an IMRT arc is made equivalent to a conventional arc with gantry-angle dependent beam apertures. The dose to the isocenter from each 1 deg. elemental arc segment is calculated by using the Clarkson scatter summation technique based on measured tissue-maximum-ratio and output factors, independent of the dose calculation model used in the IMRT planning system. For treatments requiring multiple treatment slices, the MU for the arc at each treatment slice takes into account the MU, leakage and scatter doses from other slices. This is achieved by solving a set of coupled linear equations for the MUs of all involved treatment slices. All input dosimetry data for the independent MU/isocenter point-dose calculation are measured directly. Comparison of the MU and isocenter point dose calculated by the independent program to those calculated by the Corvus planning system and to direct measurements has shown good agreement with relative difference less than ±3%. The program can be used as an independent initial MU verification for IMRT plans using the MIMiC multileaf collimators

  12. Small vertical changes in jaw relation affect motor unit recruitment in the masseter.

    Science.gov (United States)

    Terebesi, S; Giannakopoulos, N N; Brüstle, F; Hellmann, D; Türp, J C; Schindler, H J

    2016-04-01

    Strategies for recruitment of masseter muscle motor units (MUs), provoked by constant bite force, for different vertical jaw relations have not previously been investigated. The objective of this study was to analyse the effect of small changes in vertical jaw relation on MU recruitment behaviour in different regions of the masseter during feedback-controlled submaximum biting tasks. Twenty healthy subjects (mean age: 24·6 ± 2·4 years) were involved in the investigation. Intra-muscular electromyographic (EMG) activity of the right masseter was recorded in different regions of the muscle. MUs were identified by the use of decomposition software, and root-mean-square (RMS) values were calculated for each experimental condition. Six hundred and eleven decomposed MUs with significantly (P recruitment behaviour were organised into localised MU task groups. MUs with different task specificity in seven examined tasks were observed. The RMS EMG values obtained from the different recording sites were also significantly (P recruitment was significantly (P recruited MUs and the RMS EMG values decreased significantly (P recruitment behaviour in discrete subvolumes of the masseter in response to small changes in vertical jaw relations. These fine-motor skills might be responsible for its excellent functional adaptability and might also explain the successful management of temporomandibular disorder patients by somatic intervention, in particular by the use of oral splints. © 2015 John Wiley & Sons Ltd.

  13. Enhanced dynamic wedge and independent monitor unit verification

    International Nuclear Information System (INIS)

    Howlett, SJ.

    2005-01-01

    Some serious radiation accidents have occurred around the world during the delivery of radiotherapy treatment. The regrettable incident in Panama clearly indicated the need for independent monitor unit (MU) verification. Indeed the International Atomic Energy Agency (IAEA), after investigating the incident, made specific recommendations for radiotherapy centres which included an independent monitor unit check for all treatments. Independent monitor unit verification is practiced in many radiotherapy centres in developed countries around the world. It is mandatory in USA but not yet in Australia. This paper describes development of an independent MU program, concentrating on the implementation of the Enhanced Dynamic Wedge (EDW) component. The difficult case of non centre of field (COF) calculation points under the EDW was studied in some detail. Results of a survey of Australasian centres regarding the use of independent MU check systems is also presented. The system was developed with reference to MU calculations made by Pinnacle 3 D Radiotherapy Treatment Planning (RTP) system (ADAC - Philips) for 4MV, 6MV and 18MV X-ray beams used at the Newcastle Mater Misericordiae Hospital (NMMH) in the clinical environment. A small systematic error was detected in the equation used for the EDW calculations. Results indicate that COF equations may be used in the non COF situation with similar accuracy to that achieved with profile corrected methods. Further collaborative work with other centres is planned to extend these findings

  14. Groundwater Monitoring Plan for the Reactor Technology Complex Operable Unit 2-13

    International Nuclear Information System (INIS)

    Richard P. Wells

    2007-01-01

    This Groundwater Monitoring Plan describes the objectives, activities, and assessments that will be performed to support the on-going groundwater monitoring requirements at the Reactor Technology Complex, formerly the Test Reactor Area (TRA). The requirements for groundwater monitoring were stipulated in the Final Record of Decision for Test Reactor Area, Operable Unit 2-13, signed in December 1997. The monitoring requirements were modified by the First Five-Year Review Report for the Test Reactor Area, Operable Unit 2-13, at the Idaho National Engineering and Environmental Laboratory to focus on those contaminants of concern that warrant continued surveillance, including chromium, tritium, strontium-90, and cobalt-60. Based upon recommendations provided in the Annual Groundwater Monitoring Status Report for 2006, the groundwater monitoring frequency was reduced to annually from twice a year

  15. Teratogenic effect of yogurt in mice fetus (Mus musculus)

    OpenAIRE

    Dwisari Dillasamola; Almahdy A; Amirah Desri; Skunda Diliarosta

    2018-01-01

    Yogurt is one of the dairy products made from lactic acid fermentation by using Lactobacillus bulgaricus and Streptococcus thermophilus. A study on teratogenic effects of yogurt on the white female mice fetus (Mus musculus) has been carried out. Pregnant mice used were 20 which divided into 4 groups : the control group, D1, D2, and D3. The treatments giveThe mice were Distidelled water (control), 0.52 yogurt (D1), 1.04  yogurt (D2), and 2.08 g yogurt (D3). Data were analyzed using one-way ANO...

  16. Acoustic monitoring systems tests at Indian Point Unit 1. Final report

    International Nuclear Information System (INIS)

    Smith, J.R.; Rao, G.V.; Craig, J.

    1979-12-01

    This report describes the results of a program to test acoustic monitoring systems on Indian Point Unit No. 1 under actual plant operating conditions, less the reactor core. The two types of systems evaluated were the monitoring of acoustic emissions generated by growing flaws and the monitoring of acoustic signals from leaks

  17. Developed vibration waveform monitoring unit for CBM

    International Nuclear Information System (INIS)

    Hamada, T.; Hotsuta, K.; Hirose, I.; Morita, E.

    2007-01-01

    In nuclear power plants, many rotating machines such as pumps and fans are in use. Shikoku Research Institute Inc. has recently developed easy-to-use tools to facilitate the maintenance of such equipment. They include a battery-operated vibration waveform monitoring unit which allows unmanned vibration monitoring on a regular basis and data collection even from intermittently operating equipment, a waveform data collector which can be used for easy collection, storage, control, and analysis of raw vibration waveform data during normal operation, and vibration analysis and evaluation tools. A combination of these tools has a high potential for optimization of rotating equipment maintenance. (author)

  18. Emergency radiological monitoring and analysis United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1994-01-01

    The United States Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. Following a major radiological incident the FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC). The FRMAC is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted states and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis and quality assurance. This program includes: (1) Aerial Radiological Monitoring - Fixed Wing and Helicopter, (2) Field Monitoring and Sampling, (3) Radioanalysis - Mobile and Fixed Laboratories, (4) Radiation Detection Instrumentation - Calibration and Maintenance, (5) Environmental Dosimetry, and (6) An integrated program of Quality Assurance. To assure consistency, completeness and the quality of the data produced, a methodology and procedures handbook is being developed. This paper discusses the structure, assets and operations of FRMAC monitoring and analysis and the content and preparation of this handbook

  19. Forest health monitoring in the United States: focus on national reports

    Science.gov (United States)

    Kurt Riitters; Kevin Potter

    2013-01-01

    The health and sustainability of United States forests have been monitored for many years from several different perspectives. The national Forest Health Monitoring (FHM) Program was established in 1990 by Federal and State agencies to develop a national system for monitoring and reporting on the status and trends of forest ecosystem health. We describe and illustrate...

  20. An assessment of the performance of the Monitor for AeRosols and GAses in ambient air (MARGA): a semi-continuous method for soluble compounds

    Science.gov (United States)

    Rumsey, I. C.; Cowen, K. A.; Walker, J. T.; Kelly, T. J.; Hanft, E. A.; Mishoe, K.; Rogers, C.; Proost, R.; Beachley, G. M.; Lear, G.; Frelink, T.; Otjes, R. P.

    2014-06-01

    Ambient air monitoring as part of the US Environmental Protection Agency's (US EPA's) Clean Air Status and Trends Network (CASTNet) currently uses filter packs to measure weekly integrated concentrations. The US EPA is interested in supplementing CASTNet with semi-continuous monitoring systems at select sites to characterize atmospheric chemistry and deposition of nitrogen and sulfur compounds at higher time resolution than the filter pack. The Monitor for AeRosols and GAses in ambient air (MARGA) measures water-soluble gases and aerosols at an hourly temporal resolution. The performance of the MARGA was assessed under the US EPA Environmental Technology Verification (ETV) program. The assessment was conducted in Research Triangle Park, North Carolina, from 8 September to 8 October 2010 and focused on gaseous SO2, HNO3, and NH3 and aerosol SO42-, NO3-, and NH4+. Precision of the MARGA was evaluated by calculating the median absolute relative percent difference (MARPD) between paired hourly results from duplicate MARGA units (MUs), with a performance goal of ≤ 25%. The accuracy of the MARGA was evaluated by calculating the MARPD for each MU relative to the average of the duplicate denuder/filter pack concentrations, with a performance goal of ≤ 40%. Accuracy was also evaluated by using linear regression, where MU concentrations were plotted against the average of the duplicate denuder/filter pack concentrations. From this, a linear least squares line of best fit was applied. The goal was for the slope of the line of best fit to be between 0.8 and 1.2. The MARGA performed well in comparison to the denuder/filter pack for SO2, SO42-, and NH4+, with all three compounds passing the accuracy and precision goals by a significant margin. The performance of the MARGA in measuring NO3- could not be evaluated due to the different sampling efficiency of coarse NO3- by the MUs and the filter pack. Estimates of "fine" NO3- were calculated for the MUs and the filter pack

  1. Hold your horSSEs: controlling structure-selective endonucleases MUS81 and Yen1/GEN1.

    Science.gov (United States)

    Blanco, Miguel G; Matos, Joao

    2015-01-01

    Repair of DNA lesions through homologous recombination promotes the establishment of stable chromosomal interactions. Multiple helicases, topoisomerases and structure-selective endonucleases (SSEs) act upon recombining joint molecules (JMs) to disengage chromosomal connections and safeguard chromosome segregation. Recent studies on two conserved SSEs - MUS81 and Yen1/GEN1- uncovered multiple layers of regulation that operate to carefully tailor JM-processing according to specific cellular needs. Temporal restriction of SSE function imposes a hierarchy in pathway usage that ensures efficient JM-processing while minimizing reciprocal exchanges between the recombining DNAs. Whereas a conserved strategy of fine-tuning SSE functions exists in different model systems, the precise molecular mechanisms to implement it appear to be significantly different. Here, we summarize the current knowledge on the cellular switches that are in place to control MUS81 and Yen1/GEN1 functions.

  2. Genomic resources for wild populations of the house mouse, Mus musculus and its close relative Mus spretus

    Science.gov (United States)

    Harr, Bettina; Karakoc, Emre; Neme, Rafik; Teschke, Meike; Pfeifle, Christine; Pezer, Željka; Babiker, Hiba; Linnenbrink, Miriam; Montero, Inka; Scavetta, Rick; Abai, Mohammad Reza; Molins, Marta Puente; Schlegel, Mathias; Ulrich, Rainer G.; Altmüller, Janine; Franitza, Marek; Büntge, Anna; Künzel, Sven; Tautz, Diethard

    2016-01-01

    Wild populations of the house mouse (Mus musculus) represent the raw genetic material for the classical inbred strains in biomedical research and are a major model system for evolutionary biology. We provide whole genome sequencing data of individuals representing natural populations of M. m. domesticus (24 individuals from 3 populations), M. m. helgolandicus (3 individuals), M. m. musculus (22 individuals from 3 populations) and M. spretus (8 individuals from one population). We use a single pipeline to map and call variants for these individuals and also include 10 additional individuals of M. m. castaneus for which genomic data are publically available. In addition, RNAseq data were obtained from 10 tissues of up to eight adult individuals from each of the three M. m. domesticus populations for which genomic data were collected. Data and analyses are presented via tracks viewable in the UCSC or IGV genome browsers. We also provide information on available outbred stocks and instructions on how to keep them in the laboratory. PMID:27622383

  3. Condition monitoring of primary coolant pump-motor units of Indian PHWR

    International Nuclear Information System (INIS)

    Rshikesan, P.B.; Sharma, S.S.; Mhetre, S.G.

    1994-01-01

    As the primary coolant pump motor units are located in shut down accessible area, their start up, satisfactory operation and shut down are monitored from control room. As unavailability of one pump in standardised 220 MWe station reduces the station power to about 110 MWe, satisfactory operation of the pump is also important from economic considerations. All the critical parameters of pump shaft, mechanical seal, bearing system, motor winding and shaft displacement (vibrations) are monitored/recorded to ensure satisfactory operation of critical, capital intensive pump-motor units. (author). 2 tabs., 1 fig

  4. Efficacy and Palatability of Different Rodenticide Formulations Applied against House Mouse (Mus musculus L. in Plant Storage Facilities

    Directory of Open Access Journals (Sweden)

    Goran Jokić

    2008-01-01

    Full Text Available Palatability (daily intake of different rodenticide formulations based on bromadiolone was compared in experiments with house mouse (Mus musculus L. in agricultural storage facilities, and rodent numbers were assessed at the beginning and end of experiment, as well as rodenticide efficacy. The dynamic of bait intake was monitored for ten days in facilities of the Institute of Animal Husbandry in Zemun and the Agricultural Cooperatives at Starčevo and Omoljica. The experiments complied with the relevant standard method of OEPP/EPPO. Agricultural products were stored either as bulk commodities or in sacs laid on pallete racks in the treated facilities. Baits were laid in boxes on mice routes below palletes holding sacs and on places where significant damage had been observed, at 1-3 m spacing and in 10-20 g portions. Mouse abundance was estimated based on the highest and lowest daily intakes of bait by mice over a period of 10 days, which was divided by the mouse daily feed requirement. The presence of house mouse was also monitored over the next 20 days. The efficacy of test products was computed using Abbott’s formula.

  5. MUS81 promotes common fragile site expression

    DEFF Research Database (Denmark)

    Ying, Songmin; Minocherhomji, Sheroy; Chan, Kok Lung

    2013-01-01

    Fragile sites are chromosomal loci with a propensity to form gaps or breaks during early mitosis, and their instability is implicated as being causative in certain neurological disorders and cancers. Recent work has demonstrated that the so-called common fragile sites (CFSs) often impair the fait......Fragile sites are chromosomal loci with a propensity to form gaps or breaks during early mitosis, and their instability is implicated as being causative in certain neurological disorders and cancers. Recent work has demonstrated that the so-called common fragile sites (CFSs) often impair...... the faithful disjunction of sister chromatids in mitosis. However, the mechanisms by which CFSs express their fragility, and the cellular factors required to suppress CFS instability, remain largely undefined. Here, we report that the DNA structure-specific nuclease MUS81-EME1 localizes to CFS loci in early...

  6. Are ribosomal DNA clusters rearrangement hotspots? A case study in the genus Mus (Rodentia, Muridae

    Directory of Open Access Journals (Sweden)

    Douzery Emmanuel JP

    2011-05-01

    Full Text Available Abstract Background Recent advances in comparative genomics have considerably improved our knowledge of the evolution of mammalian karyotype architecture. One of the breakthroughs was the preferential localization of evolutionary breakpoints in regions enriched in repetitive sequences (segmental duplications, telomeres and centromeres. In this context, we investigated the contribution of ribosomal genes to genome reshuffling since they are generally located in pericentromeric or subtelomeric regions, and form repeat clusters on different chromosomes. The target model was the genus Mus which exhibits a high rate of karyotypic change, a large fraction of which involves centromeres. Results The chromosomal distribution of rDNA clusters was determined by in situ hybridization of mouse probes in 19 species. Using a molecular-based reference tree, the phylogenetic distribution of clusters within the genus was reconstructed, and the temporal association between rDNA clusters, breakpoints and centromeres was tested by maximum likelihood analyses. Our results highlighted the following features of rDNA cluster dynamics in the genus Mus: i rDNA clusters showed extensive diversity in number between species and an almost exclusive pericentromeric location, ii a strong association between rDNA sites and centromeres was retrieved which may be related to their shared constraint of concerted evolution, iii 24% of the observed breakpoints mapped near an rDNA cluster, and iv a substantial rate of rDNA cluster change (insertion, deletion also occurred in the absence of chromosomal rearrangements. Conclusions This study on the dynamics of rDNA clusters within the genus Mus has revealed a strong evolutionary relationship between rDNA clusters and centromeres. Both of these genomic structures coincide with breakpoints in the genus Mus, suggesting that the accumulation of a large number of repeats in the centromeric region may contribute to the high level of chromosome

  7. Portable and fixed monitoring units for tank calibrations and monitoring of process liquids

    International Nuclear Information System (INIS)

    Landat, D.A.; Hunt, B.A.

    1999-01-01

    The development work stems from safeguards support activities carried out at the JRC Ispra, Italy to the inspectorate agencies. A range of measurement equipment covering the needs of the inspector have been designed, developed and tested in both the laboratory and in nuclear facilities. The instruments comprise four units: (1) a portable pressure measurement device, (2) a volume long term monitoring device, (3) an unattended volume measurement system and (4) a level measurement unit. Utilization of the equipment has proven to give independent measurement checks and confirmation of operator's instrumentation and declarations, ensuring continuity of knowledge. (J.P.N.)

  8. Volcano-Monitoring Instrumentation in the United States, 2008

    Science.gov (United States)

    Guffanti, Marianne; Diefenbach, Angela K.; Ewert, John W.; Ramsey, David W.; Cervelli, Peter F.; Schilling, Steven P.

    2010-01-01

    The United States is one of the most volcanically active countries in the world. According to the global volcanism database of the Smithsonian Institution, the United States (including its Commonwealth of the Northern Mariana Islands) is home to about 170 volcanoes that are in an eruptive phase, have erupted in historical time, or have not erupted recently but are young enough (eruptions within the past 10,000 years) to be capable of reawakening. From 1980 through 2008, 30 of these volcanoes erupted, several repeatedly. Volcano monitoring in the United States is carried out by the U.S. Geological Survey (USGS) Volcano Hazards Program, which operates a system of five volcano observatories-Alaska Volcano Observatory (AVO), Cascades Volcano Observatory (CVO), Hawaiian Volcano Observatory (HVO), Long Valley Observatory (LVO), and Yellowstone Volcano Observatory (YVO). The observatories issue public alerts about conditions and hazards at U.S. volcanoes in support of the USGS mandate under P.L. 93-288 (Stafford Act) to provide timely warnings of potential volcanic disasters to the affected populace and civil authorities. To make efficient use of the Nation's scientific resources, the volcano observatories operate in partnership with universities and other governmental agencies through various formal agreements. The Consortium of U.S. Volcano Observatories (CUSVO) was established in 2001 to promote scientific cooperation among the Federal, academic, and State agencies involved in observatory operations. Other groups also contribute to volcano monitoring by sponsoring long-term installation of geophysical instruments at some volcanoes for specific research projects. This report describes a database of information about permanently installed ground-based instruments used by the U.S. volcano observatories to monitor volcanic activity (unrest and eruptions). The purposes of this Volcano-Monitoring Instrumentation Database (VMID) are to (1) document the Nation's existing

  9. Food preferences of wild house-mice (Mus musclus L).

    Science.gov (United States)

    Rowe, F P; Bradfield, A; Redfern, R

    1974-12-01

    The relative acceptance of various plain foods by wild house-mice (Mus musculus L.) was compared in laboratory choice tests. The palatability of glycerine and six oils, each included at 5% in pinhead oatmeal, was compared in a similar manner.The most favoured food was found to be whole canary seed (Phalaris canariensis). Pinhead oatmeal and wheat were also comparatively well accepted. Glycerine, corn oil, arachis oil and mineral oil were more palatable than either olive, linseed or cod-liver oils.The results of the choice tests are considered in relation to the use of poison baits for the control of free-living mice.

  10. Food preferences of wild house-mice (Mus musculus L.)*

    Science.gov (United States)

    Rowe, F. P.; Bradfield, A.; Redfern, R.

    1974-01-01

    The relative acceptance of various plain foods by wild house-mice (Mus musculus L.) was compared in laboratory choice tests. The palatability of glycerine and six oils, each included at 5% in pinhead oatmeal, was compared in a similar manner. The most favoured food was found to be whole canary seed (Phalaris canariensis). Pinhead oatmeal and wheat were also comparatively well accepted. Glycerine, corn oil, arachis oil and mineral oil were more palatable than either olive, linseed or cod-liver oils. The results of the choice tests are considered in relation to the use of poison baits for the control of free-living mice. PMID:4531454

  11. Srs2 and Mus81-Mms4 Prevent Accumulation of Toxic Inter-Homolog Recombination Intermediates.

    Directory of Open Access Journals (Sweden)

    Kenji Keyamura

    2016-07-01

    Full Text Available Homologous recombination is an evolutionally conserved mechanism that promotes genome stability through the faithful repair of double-strand breaks and single-strand gaps in DNA, and the recovery of stalled or collapsed replication forks. Saccharomyces cerevisiae ATP-dependent DNA helicase Srs2 (a member of the highly conserved UvrD family of helicases has multiple roles in regulating homologous recombination. A mutation (srs2K41A resulting in a helicase-dead mutant of Srs2 was found to be lethal in diploid, but not in haploid, cells. In diploid cells, Srs2K41A caused the accumulation of inter-homolog joint molecule intermediates, increased the levels of spontaneous Rad52 foci, and induced gross chromosomal rearrangements. Srs2K41A lethality and accumulation of joint molecules were suppressed by inactivating Rad51 or deleting the Rad51-interaction domain of Srs2, whereas phosphorylation and sumoylation of Srs2 and its interaction with sumoylated proliferating cell nuclear antigen (PCNA were not required for lethality. The structure-specific complex of crossover junction endonucleases Mus81 and Mms4 was also required for viability of diploid, but not haploid, SRS2 deletion mutants (srs2Δ, and diploid srs2Δ mus81Δ mutants accumulated joint molecule intermediates. Our data suggest that Srs2 and Mus81-Mms4 have critical roles in preventing the formation of (or in resolving toxic inter-homolog joint molecules, which could otherwise interfere with chromosome segregation and lead to genetic instability.

  12. A maintenance policy for two-unit parallel systems based on imperfect monitoring information

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Anne [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France)]. E-mail: anne.barros@utt.fr; Berenguer, Christophe [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France); Grall, Antoine [Department Genie des Systems Industiels (GSI), Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes, Cedex (France)

    2006-02-01

    In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model.

  13. A maintenance policy for two-unit parallel systems based on imperfect monitoring information

    International Nuclear Information System (INIS)

    Barros, Anne; Berenguer, Christophe; Grall, Antoine

    2006-01-01

    In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model

  14. Requirements for internal contamination monitoring units

    International Nuclear Information System (INIS)

    Werner, E.; Beyer, D.; Doerfel, H.; Erlenbach, H.; Fischbach, G.; Henrichs, K.; Keller, K.D.; Koenig, K.; Riedel, W.; Scheler, R.; Schieferdecker, H.

    1994-01-01

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [de

  15. 40 CFR 60.1320 - How do I monitor the load of my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... municipal waste combustion unit? 60.1320 Section 60.1320 Protection of Environment ENVIRONMENTAL PROTECTION... of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After... Monitoring Requirements § 60.1320 How do I monitor the load of my municipal waste combustion unit? (a) If...

  16. PyMUS: Python-Based Simulation Software for Virtual Experiments on Motor Unit System.

    Science.gov (United States)

    Kim, Hojeong; Kim, Minjung

    2018-01-01

    We constructed a physiologically plausible computationally efficient model of a motor unit and developed simulation software that allows for integrative investigations of the input-output processing in the motor unit system. The model motor unit was first built by coupling the motoneuron model and muscle unit model to a simplified axon model. To build the motoneuron model, we used a recently reported two-compartment modeling approach that accurately captures the key cell-type-related electrical properties under both passive conditions (somatic input resistance, membrane time constant, and signal attenuation properties between the soma and the dendrites) and active conditions (rheobase current and afterhyperpolarization duration at the soma and plateau behavior at the dendrites). To construct the muscle unit, we used a recently developed muscle modeling approach that reflects the experimentally identified dependencies of muscle activation dynamics on isometric, isokinetic and dynamic variation in muscle length over a full range of stimulation frequencies. Then, we designed the simulation software based on the object-oriented programing paradigm and developed the software using open-source Python language to be fully operational using graphical user interfaces. Using the developed software, separate simulations could be performed for a single motoneuron, muscle unit and motor unit under a wide range of experimental input protocols, and a hierarchical analysis could be performed from a single channel to the entire system behavior. Our model motor unit and simulation software may represent efficient tools not only for researchers studying the neural control of force production from a cellular perspective but also for instructors and students in motor physiology classroom settings.

  17. Zinc injection on the EDF fleet monitoring the injection on 12 units

    International Nuclear Information System (INIS)

    Le-Meur, Gaelle Harmand; Anne-Marie; Stutzmann, Agnes; Taunier, Stephane; Benfarah, Moez; Bretelle, Jean-Luc; Alain, Rocher; Claeys, Myriam; Bonne, Sebastien

    2012-09-01

    After a first implementation of zinc injection at Bugey 2 and Bugey 4, EDF decided to extend the program to other units of its fleet. 14 more reactors from the French fleet of 58 were chosen in order to - Reduce the radiation sources for curative or preventive (after SGR) reasons - Mitigate stress corrosion cracking on nickel alloys and reduce the rate of generalized corrosion - Prevent the risk of CIPS, mainly after a fuel management change. Zinc injection started on 9 new units in 2011, 1 unit in 2012 and will be extended to 4 other units before the end of 2013. To monitor the injection, EDF has defined a complete program concerning chemistry, radiation protection (dose rate and deposited activities measurements), materials (statistical analysis of SG tube cracks), fuel (oxide measurements) and waste (radiochemical characterization of filters). Reference units were chosen for each field because of the size of the fleet. This paper will detail the different monitoring programs on the EDF plants injecting zinc. (authors)

  18. PyMUS: Python-Based Simulation Software for Virtual Experiments on Motor Unit System

    Directory of Open Access Journals (Sweden)

    Hojeong Kim

    2018-04-01

    Full Text Available We constructed a physiologically plausible computationally efficient model of a motor unit and developed simulation software that allows for integrative investigations of the input–output processing in the motor unit system. The model motor unit was first built by coupling the motoneuron model and muscle unit model to a simplified axon model. To build the motoneuron model, we used a recently reported two-compartment modeling approach that accurately captures the key cell-type-related electrical properties under both passive conditions (somatic input resistance, membrane time constant, and signal attenuation properties between the soma and the dendrites and active conditions (rheobase current and afterhyperpolarization duration at the soma and plateau behavior at the dendrites. To construct the muscle unit, we used a recently developed muscle modeling approach that reflects the experimentally identified dependencies of muscle activation dynamics on isometric, isokinetic and dynamic variation in muscle length over a full range of stimulation frequencies. Then, we designed the simulation software based on the object-oriented programing paradigm and developed the software using open-source Python language to be fully operational using graphical user interfaces. Using the developed software, separate simulations could be performed for a single motoneuron, muscle unit and motor unit under a wide range of experimental input protocols, and a hierarchical analysis could be performed from a single channel to the entire system behavior. Our model motor unit and simulation software may represent efficient tools not only for researchers studying the neural control of force production from a cellular perspective but also for instructors and students in motor physiology classroom settings.

  19. SU-E-T-31: Alternative VMAT Technique Reduces Total Monitor Units for Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Happersett, L; Mechalakos, J; Kuo, L; Zhang, P; Rimner, A [Memorial Sloan-Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: To investigate an alternative approach to VMAT optimization for hypofractionation lung treatment which increases average aperture opening and results in lower total Monitor Units (MU) without significantly sacrificing plan quality. Methods: Benchmark Volumetric Modulated Arc Therapy (bVMAT) plans were generated for 10 lung Stereotactic Body radiotherapy (SBRT) cases using Eclipse Version 11.0.42 (Varian Medical Systems) without a maximum MU constraint. Prescriptions ranged from 40 to 54Gy in 3 to 5 fractions. AAA dose calculation and PRO fluence based optimization was utilized. Two comparison VMAT plans were generated for each case, one that forced an initial “open” mlc aperture conformal to the tumor as a starting condition (oVMAT) with similar optimization parameters and arc geometries, and one that repeated the bVMAT optimization but added a maximum MU constraint (muVMAT). All plans used two arcs with lengths between 168 to 230 degrees. PTV D 95% and Dmean, lung V20 Gy, chest wall V30 Gy, average aperture opening and MU's were compared. Statistical significance was evaluated using Wilcoxon signed rank test. Results: Average PTV D(95), PTV mean and lung V20Gy over all plans was 99.2 ± 1.7%, 103.3 ± 0.6% and 7.8 ± 2.4% respectively. The average chest wall V30Gy was 61 ± 61 cc and ranged between 0 to 166 cc. There were no significant differences between the three techniques for the dosimetric quantities. MUs were reduced by 11 ±11% (p<0.01) and 25 ± 5% (p<0.01) and the average aperture size was increased by 13.7 ± 14% (p=0.02) and 35.8 ± 10% (p<0.01) with muVMAT and oVMAT, respectively, compared to bVMAT. Conclusion: oVMAT and muVMAT techniques were both able to increase average aperture size and reduce total MU compared to the benchmark VMAT plan, but the magnitude of the changes observed for oVMAT was larger.

  20. Efficacy of drugs against Giardia muris in mice Mus musculus naturally infected/
    Eficácia de drogas contra Giardia muris em camundongos Mus musculus naturalmente infectados

    OpenAIRE

    Silvia Gonzalez Monteiro; Régis Adriel Zanette; Camila Belmonte Oliveira; Marcos Kipper da Silva; Aleksandro Schafer da Silva

    2008-01-01

    This study aimed to evaluate the efficacy of metronidazole, fenbendazole and secnidazole against Giardia muris in mice naturally infected. Forty mice of the species Mus musculus were divided in four groups of ten each, being group A non treated, the control group and groups B, C and D treated with 4mg/ml of metronidazole, fenbendazole and secnidazole, respectively. Two feces collection, on day 0 and on day 10 after treatment, were done in order to evaluate the efficacy of the drugs. Samples w...

  1. Inferring Pongo conservation units: a perspective based on microsatellite and mitochondrial DNA analyses.

    Science.gov (United States)

    Kanthaswamy, Sreetharan; Kurushima, Jennifer D; Smith, David Glenn

    2006-10-01

    In order to define evolutionarily significant and management units (ESUs and MUs) among subpopulations of Sumatran (Pongo pygmaeus abelii) and Bornean (P. p. pygmaeus) orangutans we determined their genetic relationships. We analyzed partial sequences of four mitochondrial genes and nine autosomal microsatellite loci of 70 orangutans to test two hypotheses regarding the population structure within Borneo and the genetic distinction between Bornean and Sumatran orangutans. Our data show Bornean orangutans consist of two genetic clusters-the western and eastern clades. Each taxon exhibits relatively distinct mtDNA and nuclear genetic distributions that are likely attributable to genetic drift. These groups, however, do not warrant designations as separate conservation MUs because they demonstrate no demographic independence and only moderate genetic differentiation. Our findings also indicate relatively high levels of overall genetic diversity within Borneo, suggesting that observed habitat fragmentation and erosion during the last three decades had limited influence on genetic variability. Because the mtDNA of Bornean and Sumatran orangutans are not strictly reciprocally monophyletic, we recommend treating these populations as separate MUs and discontinuing inter-island translocation of animals unless absolutely necessary.

  2. Methylation patterns of repetitive DNA sequences in germ cells of Mus musculus.

    OpenAIRE

    Sanford, J; Forrester, L; Chapman, V; Chandley, A; Hastie, N

    1984-01-01

    The major and the minor satellite sequences of Mus musculus were undermethylated in both sperm and oocyte DNAs relative to the amount of undermethylation observed in adult somatic tissue DNA. This hypomethylation was specific for satellite sequences in sperm DNA. Dispersed repetitive and low copy sequences show a high degree of methylation in sperm DNA; however, a dispersed repetitive sequence was undermethylated in oocyte DNA. This finding suggests a difference in the amount of total genomic...

  3. Comparison ecological characteristics of mound-building mouse (mus spicilegus in two natural hotbeds of tularemia at North-West coast of the Black sea

    Directory of Open Access Journals (Sweden)

    І. T. Rusev

    2011-03-01

    Full Text Available The analysis of ecology-epizootic monitoring of North-West coast of the Black sea carried out in wintering seasons of 2004, 2005 and 2011 testifies the basic role of the Mound-building mouse (Mus spicilegus Petenyi, 1882 as a carrier of Francisella tularensis. Spatial distribution of the Mound-building mouse strongly dependson a biotope, geographical region and weather conditions of a specific season. Mice nests in the storage mounds are located normally at a depth of 20–40 cm under the food storage chamber. Average number of the mice in storage mounds is 3.08 ± 1.54 in the south of investigated region and 3.88 ± 2.63 – in the NE of the region.

  4. Novel laboratory mouse papillomavirus (MusPV) infection.

    Science.gov (United States)

    Ingle, A; Ghim, S; Joh, J; Chepkoech, I; Bennett Jenson, A; Sundberg, J P

    2011-03-01

    Most papillomaviruses (PVs) are oncogenic. There are at least 100 different human PVs and 65 nonhuman vertebrate hosts, including wild rodents, which have species-specific PV infections. Florid papillomatosis arose in a colony of NMRI-Foxn1(nu)/Foxn1(nu) (nude) mice at the Advanced Centre for Treatment Research and Education in Cancer in India. Lesions appeared at the mucocutaneous junctions of the nose and mouth. Histologically, lesions were classical papillomas with epidermal hyperplasia on thin fibrovascular stalks in a verrucous pattern. Koilocytotic cells were observed in the stratum granulosum of the papillomatous lesions. Immunohistochemically, these abnormal cells were positive for PV group-specific antigens. With transmission electron microscopy, virus particles were observed in crystalline intranuclear inclusions within keratinocytes. The presence of a mouse PV, designated MusPV, was confirmed by amplification of PV DNA with degenerative primers specific for PVs. This report is the first of a PV and its related disease in laboratory mice.

  5. Physiological consequences of doublet discharges on motoneuronal firing and motor unit force

    Directory of Open Access Journals (Sweden)

    Włodzimierz eMrówczyński

    2015-03-01

    Full Text Available The double discharges are observed at the onset of contractions of mammalian motor units (MUs, especially during their recruitment to strong or fast movements. Doublets lead to MU force increase and improve ability of muscles to maintain high force during prolonged contractions. In this review we discuss an ability to produce doublets by fast and slow motoneurons (MNs, their influence on the course of action potential afterhyperpolarization as well as its role in modulation of the initial stage of the firing pattern of MNs. In conclusion, a generation of doublets is an important strategy of motor control, responsible for fitting the motoneuronal firing rate to the optimal for MUs at the start of their contraction, necessary for increment of muscle force.

  6. SU-E-T-551: Monitor Unit Optimization in Stereotactic Body Radiation Therapy for Stage I Lung Cancer

    International Nuclear Information System (INIS)

    Huang, B-T; Lu, J-Y

    2015-01-01

    Purpose: The study aims to reduce the monitor units (MUs) in the stereotactic body radiation therapy (SBRT) treatment for lung cancer by adjusting the optimizing parameters. Methods: Fourteen patients suffered from stage I Non-Small Cell Lung Cancer (NSCLC) were enrolled. Three groups of parameters were adjusted to investigate their effects on MU numbers and organs at risk (OARs) sparing: (1) the upper objective of planning target volume (UOPTV); (2) strength setting in the MU constraining objective; (3) max MU setting in the MU constraining objective. Results: We found that the parameters in the optimizer influenced the MU numbers in a priority, strength and max MU dependent manner. MU numbers showed a decreasing trend with the UOPTV increasing. MU numbers with low, medium and high priority for the UOPTV were 428±54, 312±48 and 258±31 MU/Gy, respectively. High priority for UOPTV also spared the heart, cord and lung while maintaining comparable PTV coverage than the low and medium priority group. It was observed that MU numbers tended to decrease with the strength increasing and max MU setting decreasing. With maximum strength, the MU numbers reached its minimum while maintaining comparable or improved dose to the normal tissues. It was also found that the MU numbers continued to decline at 85% and 75% max MU setting but no longer to decrease at 50% and 25%. Combined with high priority for UOPTV and MU constraining objectives, the MU numbers can be decreased as low as 223±26 MU/Gy. Conclusion:: The priority of UOPTV, MU constraining objective in the optimizer impact on the MU numbers in SBRT treatment for lung cancer. Giving high priority to the UOPTV, setting the strength to maximum value and the max MU to 50% in the MU objective achieves the lowest MU numbers while maintaining comparable or improved OAR sparing

  7. Poster - 21: Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans

    International Nuclear Information System (INIS)

    Kosztyla, Robert; Pierce, Greg; Ploquin, Nicolas; Roumeliotis, Michael; Schinkel, Colleen

    2016-01-01

    Purpose: To determine the source of systematic monitor unit (MU) calculation discrepancies between RadCalc and Eclipse treatment planning software for three-dimensional conformal radiotherapy field-in-field breast treatments. Methods: Data were reviewed for 28 patients treated with a field-in-field breast technique with MU calculations from RadCalc that were larger than MU calculations from Eclipse for at least one field. The distance of the calculation point from the jaws was measured in each field’s beam’s-eye-view and compared with the percentage difference in MU (%ΔMU) between RadCalc and Eclipse. 10×10, 17×13 and 20×20 cm 2 beam profiles were measured using the Profiler 2 diode array for 6-MV photon beams and compared with profiles calculated with Eclipse and RadCalc using a gamma analysis (3%, 3 mm). Results: The mean %ΔMU was 1.3%±0.3%. There was a statistically-significant correlation between %ΔMU and the distance of the calculation point from the Y jaw (r=−0.43, p<0.001). RadCalc profiles differed from measured profiles, especially near the jaws. The gamma pass rate for 6-MV fields of 17×13 cm 2 field size was 95%±1% for Eclipse-generated profiles and 53%±20% for RadCalc-generated profiles (p=0.01). Conclusions: Calculations using RadCalc for field-in-field breast plans resulted in MUs that were larger than expected from previous clinical experience with wedged plans with calculation points far from the jaws due to the position of the calculation point near the jaws in the beam’s-eye-view of each field.

  8. Poster - 21: Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kosztyla, Robert; Pierce, Greg; Ploquin, Nicolas; Roumeliotis, Michael; Schinkel, Colleen [Tom Baker Cancer Centre, Calgary, AB, Tom Baker Cancer Centre, Tom Baker Cancer Centre, Tom Baker Cancer Centre, Calgary, AB, Tom Baker Cancer Centre, Calgary, AB (Canada)

    2016-08-15

    Purpose: To determine the source of systematic monitor unit (MU) calculation discrepancies between RadCalc and Eclipse treatment planning software for three-dimensional conformal radiotherapy field-in-field breast treatments. Methods: Data were reviewed for 28 patients treated with a field-in-field breast technique with MU calculations from RadCalc that were larger than MU calculations from Eclipse for at least one field. The distance of the calculation point from the jaws was measured in each field’s beam’s-eye-view and compared with the percentage difference in MU (%ΔMU) between RadCalc and Eclipse. 10×10, 17×13 and 20×20 cm{sup 2} beam profiles were measured using the Profiler 2 diode array for 6-MV photon beams and compared with profiles calculated with Eclipse and RadCalc using a gamma analysis (3%, 3 mm). Results: The mean %ΔMU was 1.3%±0.3%. There was a statistically-significant correlation between %ΔMU and the distance of the calculation point from the Y jaw (r=−0.43, p<0.001). RadCalc profiles differed from measured profiles, especially near the jaws. The gamma pass rate for 6-MV fields of 17×13 cm{sup 2} field size was 95%±1% for Eclipse-generated profiles and 53%±20% for RadCalc-generated profiles (p=0.01). Conclusions: Calculations using RadCalc for field-in-field breast plans resulted in MUs that were larger than expected from previous clinical experience with wedged plans with calculation points far from the jaws due to the position of the calculation point near the jaws in the beam’s-eye-view of each field.

  9. 40 CFR Table 11 to Subpart G of... - Wastewater-Inspection and Monitoring Requirements for Waste Management Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Wastewater-Inspection and Monitoring Requirements for Waste Management Units 11 Table 11 to Subpart G of Part 63 Protection of Environment... and Monitoring Requirements for Waste Management Units To comply with Inspection or monitoring...

  10. Geographic phenetic variation of two eastern-Mediterranean non-commensal mouse species, Mus macedonicus and M. cypriacus (Rodentia: Muridae) based on traditional and geometric approaches to morphometrics

    Czech Academy of Sciences Publication Activity Database

    Macholán, Miloš; Mikula, Ondřej; Vohralík, V.

    2008-01-01

    Roč. 247, - (2008), s. 67-80 ISSN 0044-5231 R&D Projects: GA AV ČR IAA6045307; GA ČR GA206/06/0707 Grant - others:GA ČR(CZ) GA206/05/2334 Institutional research plan: CEZ:AV0Z50450515 Keywords : Mus macedonicus * Mus cypriacus * phenotypic variation Subject RIV: EG - Zoology Impact factor: 1.319, year: 2008

  11. Chromosomal heterozygosity and fertility in house mice (Mus musculus domesticus) from Northern Italy.

    OpenAIRE

    Hauffe, H C; Searle, J B

    1998-01-01

    Following the discovery of over 40 Robertsonian (Rb) races of Mus musculus domesticus in Europe and North Africa, the house mouse has been studied extensively as an ideal model to determine the chromosomal changes that may cause or accompany speciation. Current models of chromosomal speciation are based on the assumption that heterozygous individuals have a particularly low fertility, although recent studies indicate otherwise. Despite their importance, fertility estimates for the house mouse...

  12. Converter Monitoring Unit for Retrofit of Wind Power Converters

    DEFF Research Database (Denmark)

    Rannestad, Bjorn; Maarbjerg, Anders Eggert; Frederiksen, Kristian

    2018-01-01

    A Converter Monitoring Unit (CMU), which will enable condition monitoring of wind turbine converters is presented in this paper. Reducing the cost of corrective maintenance by means of condition monitoring is a way of lowering Operation & Maintenance (O&M) costs for wind turbine systems....... The CMU must be able to detect a broad range of failure modes related to Insulated Gate Bipolar Transistor (IGBT) power modules and associated gate drives. IGBT collector-emitter on-state voltage (vceon) and current (ic) is sampled in the CMU and used for detection of emerging failures. A new method...... for compensation of unwanted inductive voltage drop in the vceon measurement path is presented, enabling retrofitting of CMUs in existing wind turbines. Finally, experimental results obtained on a prototype CMU are presented. Experimentally the vceon dependency to IGBT junction temperature and deterioration...

  13. Monitor units are not predictive of neutron dose for high-energy IMRT

    Directory of Open Access Journals (Sweden)

    Hälg Roger A

    2012-08-01

    Full Text Available Abstract Background Due to the substantial increase in beam-on time of high energy intensity-modulated radiotherapy (>10 MV techniques to deliver the same target dose compared to conventional treatment techniques, an increased dose of scatter radiation, including neutrons, is delivered to the patient. As a consequence, an increase in second malignancies may be expected in the future with the application of intensity-modulated radiotherapy. It is commonly assumed that the neutron dose equivalent scales with the number of monitor units. Methods Measurements of neutron dose equivalent were performed for an open and an intensity-modulated field at four positions: inside and outside of the treatment field at 0.2 cm and 15 cm depth, respectively. Results It was shown that the neutron dose equivalent, which a patient receives during an intensity-modulated radiotherapy treatment, does not scale with the ratio of applied monitor units relative to an open field irradiation. Outside the treatment volume at larger depth 35% less neutron dose equivalent is delivered than expected. Conclusions The predicted increase of second cancer induction rates from intensity-modulated treatment techniques can be overestimated when the neutron dose is simply scaled with monitor units.

  14. Design and accomplishment for the monitoring unit of the sup 6 sup 0 Co train freight inspection system

    CERN Document Server

    Cong Peng

    2002-01-01

    The sup 6 sup 0 Co railway cargo inspection system has super automaticity. And the monitoring unit is an important part of the automatic control system. The author introduces the idea of designing the monitoring unit in detail and accomplishes a new-style unit which is different from the traditional one. The monitoring unit which is highly integrated, easy to be mounted and debugged and convenient to be operated and maintained has play an excellent role in the work of the whole inspection system

  15. A microcontroller based readout unit for a smart personnel monitoring TLD badge

    International Nuclear Information System (INIS)

    Gaonkar, U.P.; Kulkarni, M.S.; Kannan, S.

    1997-01-01

    An automated TLD personnel monitoring system is under development to cope up with the requirements of personnel monitoring of rapidly growing number of radiation workers. The core of the system is a smart TLD badge incorporating a memory device and a microcontroller based readout unit for reading the memory contents of the badge. The memory is used to store personnel data including the accumulated dose data. The reader unit has a serial RS 232C interface for connection to a PC for entering/modifying data in the memory. A password protected software has also been developed in C for entering/modifying the data in the single memory. 3 figs

  16. Exploding Head Syndrome in the Epilepsy Monitoring Unit: Case Report and Literature Review.

    Science.gov (United States)

    Gillis, Kara; Ng, Marcus C

    2017-01-01

    Diagnosis of paroxysmal events in epilepsy patients is often made through video-telemetry electroencephalography in the epilepsy monitoring unit. This case report describes the first-ever diagnosis of exploding head syndrome in a patient with longstanding epilepsy and novel nocturnal events. In this report, we describe the presentation of exploding head syndrome and its prevalence and risk factors. In addition, the prevalence of newly diagnosed sleep disorders through video-telemetry electroencephalography in the epilepsy monitoring unit is briefly reviewed. This report also illustrates the novel use of clobazam for the treatment of exploding head syndrome.

  17. Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit.

    Science.gov (United States)

    Lilja-Cyron, Alexander; Kelsen, Jesper; Andresen, Morten; Fugleholm, Kåre; Juhler, Marianne

    2018-05-03

    Intracranial pressure (ICP) monitoring is crucial in the management of acute neurosurgical conditions such as traumatic brain injury (TBI). However, pathological ICP may persist beyond the admission to the neuro intensive care unit (NICU). We investigated the feasibility of telemetric ICP monitoring in the NICU, as this technology provides the possibility of long-term ICP assessment beyond NICU discharge. In this prospective investigation, we implanted telemetric ICP sensors (Raumedic Neurovent-P-tel) instead of conventional, cabled ICP sensors in patients undergoing decompressive craniectomy. We recorded ICP curves, duration of ICP monitoring, signal quality, and complications. Seventeen patients were included (median age 55 years) and diagnoses were: severe TBI (8), malignant middle cerebral artery infarction (8), and spontaneous intracerebral hemorrhage (1). In total, 3015 h of ICP monitoring were performed, and the median duration of ICP monitoring was 188 h (interquartile range [IQR] 54-259). The ICP signal was lost 613 times (displacement of the reader unit on the skin) for a median of 1.5 min, corresponding to 0.8% of the total monitoring period. When the signal was lost, it could always be restored by realignment of the reader unit on the skin above the telemetric sensor. Sixteen of 17 patients survived the NICU admission, and ICP gradually decreased from 10.7 mm Hg (IQR 7.5-13.6) during the first postoperative day to 6.3 mm Hg (IQR 4.0-8.3) after 1 week in the NICU. All 17 implanted telemetric sensors functioned throughout the NICU admission, and no wound infections were observed. Therefore, telemetric ICP monitoring in an acute neurosurgical setting is feasible. Signal quality and stability are sufficient for clinical decision making based on mean ICP. The low sampling frequency (5 Hz) does not permit analysis of intracranial pulse wave morphology, but resolution is sufficient for calculation of derived indices such as the pressure reactivity

  18. 76 FR 75523 - Vessel Monitoring Systems; Approved Mobile Transmitting Units and Communications Service...

    Science.gov (United States)

    2011-12-02

    ... Monitoring Systems; Approved Mobile Transmitting Units and Communications Service Providers for Use in... relevant features of the enhanced mobile transmitting unit (E-MTU) VMS and communications service providers... with the Orbcomm mobile communications provider service. Skymate can be reached at 866-SKYMATE and...

  19. An advanced NSSS integrity monitoring system for Shin-Kori nuclear units 3 and 4

    International Nuclear Information System (INIS)

    Oh, Y. G.; Kim, H. B.; Galin, S. R.; Kim, S. H.; Lee, S. J.

    2009-01-01

    The advanced design features of NSSS (Nuclear Steam Supply System) Integrity Monitoring System for Shin-Kori Nuclear Units 3 and 4 are summarized herein. During the overall system design and detailed component design processes, many design improvements have been made for the system. The major design changes are: 1) the application of a common software platform for all subsystems, 2) the implementation of remote access, control and monitoring capabilities, and 3) the equipment redesign and rearrangement that has simplified the system architecture. Changes give an effect on cabinet size, number of cables, cyber-security, graphic user interfaces, and interfaces with other monitoring systems. The system installation and operation for Shin-Kori Nuclear Units 3 and 4 will be more convenient than those for previous Korean nuclear units in view of its remote control capability, automated test functions, improved user interface functions, and much less cabling. (authors)

  20. An Advanced NSSS Integrity Monitoring System for Shin-Kori Nuclear Units 3 and 4

    Science.gov (United States)

    Oh, Yang Gyun; Galin, Scott R.; Lee, Sang Jeong

    2010-12-01

    The advanced design features of NSSS (Nuclear Steam Supply System) Integrity Monitoring System for Shin-Kori Nuclear Units 3 and 4 are summarized herein. During the overall system design and detailed component design processes, many design improvements have been made for the system. The major design changes are: 1) the application of a common software platform for all subsystems, 2) the implementation of remote access, control and monitoring capabilities, and 3) the equipment redesign and rearrangement that has simplified the system architecture. Changes give an effect on cabinet size, number of cables, cyber-security, graphic user interfaces, and interfaces with other monitoring systems. The system installation and operation for Shin-Kori Nuclear Units 3 and 4 will be more convenient than those for previous Korean nuclear units in view of its remote control capability, automated test functions, improved user interface functions, and much less cabling.

  1. Enhanced dynamic wedge and independent monitor unit verification

    International Nuclear Information System (INIS)

    Howlett, S.J.; University of Newcastle, NSW

    2004-01-01

    Full text: Some serious radiation accidents have occurred around the world during the delivery of radiotherapy treatment. The regrettable incident in Panama clearly indicated the need for independent monitor unit (MU) verification. Indeed the International Atomic Energy Agency (IAEA), after investigating the incident, made specific recommendations for radiotherapy centres which included an independent monitor unit check for all treatments. Independent monitor unit verification is practiced in many radiotherapy centres in developed countries around the world. It is mandatory in USA but not yet in Australia. The enhanced dynamic wedge factor (EDWF) presents some significant problems in accurate MU calculation, particularly in the case of non centre of field position (COF). This paper describes development of an independent MU program, concentrating on the implementation of the EDW component. The difficult case of non COF points under the EDW was studied in detail. A survey of Australasian centres regarding the use of independent MU check systems was conducted. The MUCalculator was developed with reference to MU calculations made by Pinnacle 3D RTP system (Philips) for 4MV, 6MV and 18MV X-ray beams from Varian machines used at the Newcastle Mater Misericordiae Hospital (NMMH) in the clinical environment. Ionisation chamber measurements in solid water TM and liquid water were performed based on a published test data set. Published algorithms combined with a depth dependent profile correction were applied in an attempt to match measured data with maximum accuracy. The survey results are presented. Substantial data is presented in tabular form and extensive comparison with published data. Several different methods for calculating EDWF are examined. A small systematic error was detected in the Gibbon equation used for the EDW calculations. Generally, calculations were within +2% of measured values, although some setups exceeded this variation. Results indicate that COF

  2. The extratemporal lobe epilepsies in the epilepsy monitoring unit

    Science.gov (United States)

    Dash, Deepa; Tripathi, Manjari

    2014-01-01

    Extratemporal lobe epilepsies (ETLE) are characterized by the epileptogenic foci outside the temporal lobe. They have a wide spectrum of semiological presentation depending upon the site of origin. They can arise from frontal, parietal, occipital lobes and from hypothalamic hamartoma. We discuss in this review the semiology of different types of ETLE encountered in the epilepsy monitoring unit. PMID:24791090

  3. Adaptation of motor unit contractile properties in rat medial gastrocnemius to treadmill endurance training: Relationship to muscle mitochondrial biogenesis.

    Science.gov (United States)

    Kryściak, Katarzyna; Majerczak, Joanna; Kryściak, Jakub; Łochyński, Dawid; Kaczmarek, Dominik; Drzymała-Celichowska, Hanna; Krutki, Piotr; Gawedzka, Anna; Guzik, Magdalena; Korostynski, Michał; Szkutnik, Zbigniew; Pyza, Elżbieta; Jarmuszkiewicz, Wiesława; Zoladz, Jerzy A; Celichowski, Jan

    2018-01-01

    This study aimed at investigating the effects of 2, 4 and 8 weeks of endurance training on the contractile properties of slow (S), fast fatigue resistant (FR) and fast fatigable (FF) motor units (MUs) in rat medial gastrocnemius (MG) in relation to the changes in muscle mitochondrial biogenesis. The properties of functionally isolated MUs were examined in vivo. Mitochondrial biogenesis was judged based on the changes in mitochondrial DNA copy number (mtDNA), the content of the electron transport chain (ETC) proteins and PGC-1α in the MG. Moreover, the markers of mitochondria remodeling mitofusins (Mfn1, Mfn2) and dynamin-like protein (Opa1) were studied using qPCR. A proportion of FR MUs increased from 37.9% to 50.8% and a proportion of FF units decreased from 44.7% to 26.6% after 8 weeks of training. The increased fatigue resistance, shortened twitch duration, and increased ability to potentiate force were found as early as after 2 weeks of endurance training, predominantly in FR MUs. Moreover, just after 2 weeks of the training an enhancement of the mitochondrial network remodeling was present as judged by an increase in expression of Mfn1, Opa1 and an increase in PGC-1α in the slow part of MG. Interestingly, no signs of intensification of mitochondrial biogenesis assessed by ETC proteins content and mtDNA in slow and fast parts of gastrocnemius were found at this stage of the training. Nevertheless, after 8 weeks of training an increase in the ETC protein content was observed, but mainly in the slow part of gastrocnemius. Concluding, the functional changes in MUs' contractile properties leading to the enhancement of muscle performance accompanied by an activation of signalling that controls the muscle mitochondrial network reorganisation and mitochondrial biogenesis belong to an early muscle adaptive responses that precede an increase in mitochondrial ETC protein content.

  4. A high arctic experience of uniting research and monitoring

    Science.gov (United States)

    Schmidt, Niels Martin; Christensen, Torben R.; Roslin, Tomas

    2017-07-01

    Monitoring is science keeping our thumb on the pulse of the environment to detect any changes of concern for societies. Basic science is the question-driven search for fundamental processes and mechanisms. Given the firm root of monitoring in human interests and needs, basic sciences have often been regarded as scientifically "purer"—particularly within university-based research communities. We argue that the dichotomy between "research" and "monitoring" is an artificial one, and that this artificial split clouds the definition of scientific goals and leads to suboptimal use of resources. We claim that the synergy between the two scientific approaches is well distilled by science conducted under extreme logistic constraints, when scientists are forced to take full advantage of both the data and the infrastructure available. In evidence of this view, we present our experiences from two decades of uniting research and monitoring at the remote research facility Zackenberg in High Arctic Greenland. For this site, we show how the combination of insights from monitoring with the mechanistic understanding obtained from basic research has yielded the most complete understanding of the system—to the benefit of all, and as an example to follow. We therefore urge scientists from across the continuum from monitoring to research to come together, to disregard old division lines, and to work together to expose a comprehensive picture of ecosystem change and its consequences.

  5. 75 FR 63445 - Vessel Monitoring Systems; Approved Mobile Transmitting Units and Communications Service...

    Science.gov (United States)

    2010-10-15

    ... Monitoring Systems; Approved Mobile Transmitting Units and Communications Service Providers for Use in the... features of the VMS. ADDRESSES: To obtain copies of the list of NOAA-approved VMS mobile transmitting units and NOAA-approved VMS communications service providers, please contact the VMS Support Center at...

  6. Spread-out Bragg peak and monitor units calculation with the Monte Carlo Code MCNPX

    International Nuclear Information System (INIS)

    Herault, J.; Iborra, N.; Serrano, B.; Chauvel, P.

    2007-01-01

    The aim of this work was to study the dosimetric potential of the Monte Carlo code MCNPX applied to the protontherapy field. For series of clinical configurations a comparison between simulated and experimental data was carried out, using the proton beam line of the MEDICYC isochronous cyclotron installed in the Centre Antoine Lacassagne in Nice. The dosimetric quantities tested were depth-dose distributions, output factors, and monitor units. For each parameter, the simulation reproduced accurately the experiment, which attests the quality of the choices made both in the geometrical description and in the physics parameters for beam definition. These encouraging results enable us today to consider a simplification of quality control measurements in the future. Monitor Units calculation is planned to be carried out with preestablished Monte Carlo simulation data. The measurement, which was until now our main patient dose calibration system, will be progressively replaced by computation based on the MCNPX code. This determination of Monitor Units will be controlled by an independent semi-empirical calculation

  7. 40 CFR Table 7 to Subpart Ggg of... - Wastewater-Inspection and Monitoring Requirements for Waste Management Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Wastewater-Inspection and Monitoring Requirements for Waste Management Units 7 Table 7 to Subpart GGG of Part 63 Protection of Environment... for Waste Management Units To comply with Inspection or monitoring requirement Frequency of inspection...

  8. Efficacy of drugs against Giardia muris in mice Mus musculus naturally infected/ Eficácia de drogas contra Giardia muris em camundongos Mus musculus naturalmente infectados

    Directory of Open Access Journals (Sweden)

    Silvia Gonzalez Monteiro

    2008-08-01

    Full Text Available This study aimed to evaluate the efficacy of metronidazole, fenbendazole and secnidazole against Giardia muris in mice naturally infected. Forty mice of the species Mus musculus were divided in four groups of ten each, being group A non treated, the control group and groups B, C and D treated with 4mg/ml of metronidazole, fenbendazole and secnidazole, respectively. Two feces collection, on day 0 and on day 10 after treatment, were done in order to evaluate the efficacy of the drugs. Samples were analyzed by the centrifugal-flotation method with zinc sulfate. Efficacy of 97,05% for metronidazole, 98,30% for fenbendazole and 100% for secnidazole were observed in the study. According to the results it was concluded that the tested drugs were effective for the treatment of mice parasitized by Giardia muris.Este estudo visou avaliar a eficácia do metronidazol, fenbendazole e secnidazol contra Giardia muris em camundongos naturalmente infectados. Foram utilizados 40 camundongos da espécie Mus musculus divididos em quatro grupos de 10 animais cada, sendo grupo A, grupo controle, não tratados, e grupos B, C e D tratados com 4mg/ml de metronidazol, fenbendazole e secnidazol, respectivamente. Para avaliar a eficácia dos medicamentos foram realizadas duas coletas de fezes uma no dia zero e outra 10 dias após tratamento. As amostras foram processadas e analisadas a partir do método de centrífugo-flutuação com sulfato de zinco. No estudo observou-se eficácia de 97,05% para metronidazol, 98,30% para fenbendazole e 100% para secnidazol no tratamento de giardiase murina. Com base nos resultados concluí-se que as drogas testadas apresentaram eficácia no tratamento de camundongos parasitados por Giardia muris.

  9. Recruitment order of quadriceps motor units: femoral nerve vs. direct quadriceps stimulation.

    Science.gov (United States)

    Rodriguez-Falces, Javier; Place, Nicolas

    2013-12-01

    To investigate potential differences in the recruitment order of motor units (MUs) in the quadriceps femoris when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. M-waves and mechanical twitches were evoked using femoral nerve stimulation and direct quadriceps stimulation of gradually increasing intensity from 20 young, healthy subjects. Recruitment order was investigated by analysing the time-to-peak twitch and the time interval from the stimulus artefact to the M-wave positive peak (M-wave latency) for the vastus medialis (VM) and vastus lateralis (VL) muscles. During femoral nerve stimulation, time-to-peak twitch and M-wave latency decreased consistently (P  0.05). For the VM muscle, M-wave latency decreased with increasing stimulation level for both femoral nerve and direct quadriceps stimulation, whereas, for the VL muscle, the variation of M-wave latency with stimulus intensity was different for the two stimulation geometries (P recruitment order during direct quadriceps stimulation was more complex, depending ultimately on the architecture of the peripheral nerve and its terminal branches below the stimulating electrodes for each muscle. For the VM, MUs were orderly recruited for both stimulation geometries, whereas, for the VL muscle, MUs were orderly recruited for femoral nerve stimulation, but followed no particular order for direct quadriceps stimulation.

  10. PENGARUH PEMBERIAN “KOMBUCHA” TEH ROSELLA TERHADAP PROFIL DARAH MENCIT (Mus musculus L)

    OpenAIRE

    Mukhani Dwi Hidayanti; Sussi Astuti; Maria Erna Kustyawati

    2015-01-01

    “Kombucha” rosella tea is a functional fermented beverage product solution from the petals of rosella tea and sugar using a microbial starter “Kombucha” (Acetobacter xylinum and several kind of yeast). The objective of the experiment was to determine the effect of “Kombucha” rosella tea on the blood profile of mice (Mus musculus L). The experiment compiled in a completely randomized design with 4 treatments dose “Kombucha” rosella tea was 0,73 ml/20 g BB mice (distilled water) (K), 0,36 ml...

  11. Safety Improvement in Radiotherapy Treatment Plan. Planning vs Redundant Check vs in vivo Dosimetry

    International Nuclear Information System (INIS)

    Torres Diaz, J.; Ascencion Ybarra, Y.; La Fuentes Rosales, L. de; Lara Mas, E.; Larrinaga Cortinas, E.

    2013-01-01

    In Cuba it is mandatory to have an independent monitor units check before any radiotherapy treatment is started. The main objective of this paper is to enhance the safety of the radiotherapy planning by developing and testing a practical tool to double check the monitor units calculation for external beam high energy photon therapy. A software for monitor units (MUs) verification was designed and coded. It considers the common in clinical practice isocentric set-ups. The in vivo dosimetry measurements were done with a silicon diode system for 6 MV photon beams to support the validation of the software. The results show a discrepancy within 5% between the 3 methods which is in accordance with international recommendations. (Author)

  12. Identifying common practices and challenges for local urban tree monitoring programs across the United States

    Science.gov (United States)

    Lara A. Roman; E. Gregory McPherson; Bryant C. Scharenbroch; Julia. Bartens

    2013-01-01

    Urban forest monitoring data are essential to assess the impacts of tree planting campaigns and management programs. Local practitioners have monitoring projects that have not been well documented in the urban forestry literature. To learn more about practitioner-driven monitoring efforts, the authors surveyed 32 local urban forestry organizations across the United...

  13. Re-evaluation of the holotype of Mus ruber Jentink, 1880 (Rodentia: Muridae) from western New Guinea (Irian Jaya)

    NARCIS (Netherlands)

    Calaby, J.H.; Mary Taylor, J.

    1980-01-01

    INTRODUCTION The first rodent from the New Guinea region, now included in the genus Rattus, to be formally named, was Mus ruber Jentink, 1880. The name R. ruber is currently in widespread use (Lidicker, 1968, 1973; Lidicker & Ziegler, 1968; Misonne, 1969; Ziegler, 1971; Bulmer & Menzies, 1972, 1973;

  14. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Teacher's Guide.

    Science.gov (United States)

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  15. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.

    Science.gov (United States)

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  16. Quelques espèces nouvelles d’hispides de Sumatra appartenant au Musée de Leyde

    NARCIS (Netherlands)

    Gestro, R.

    1897-01-01

    Sur le point d’entreprendre l’étude des Hispides recueillies à Sumatra par M. le Doct. E. Modigliani, j’ai demandé à M. Ritsema, le savant conservateur de la collection d’insectes du Musée de Leyde, la communication de quelques espèces dans le but de faciliter mon travail. Mon aimable collègue a

  17. Independent dose per monitor unit review of eight U.S.A. proton treatment facilities

    International Nuclear Information System (INIS)

    Moyers, M. F.; Ibbott, G. S.; Grant, R. L.; Summers, P. A.; Followill, D. S.

    2014-01-01

    Purpose: Compare the dose per monitor unit at different proton treatment facilities using three different dosimetry methods. Methods: Measurements of dose per monitor unit were performed by a single group at eight facilities using 11 test beams and up to six different clinical portal treatment sites. These measurements were compared to the facility reported dose per monitor unit values. Results: Agreement between the measured and reported doses was similar using any of the three dosimetry methods. Use of the ICRU 59 N D,w based method gave results approximately 3% higher than both the ICRU 59 N X and ICRU 78 (TRS-398) N D,w based methods. Conclusions: Any single dosimetry method could be used for multi-institution trials with similar conformity between facilities. A multi-institutional trial could support facilities using both the ICRU 59 N X based and ICRU 78 (TRS-398) N D,w based methods but use of the ICRU 59 N D,w based method should not be allowed simultaneously with the other two until the difference is resolved

  18. Evaluating the Use of Tissue Oximetry to Decrease Intensive Unit Monitoring for Free Flap Breast Reconstruction.

    Science.gov (United States)

    Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T

    2017-07-01

    Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.

  19. Wireless transmission design for health monitoring at neonatal intensive care units

    NARCIS (Netherlands)

    Chen, W.; Nguyen, S.T.; Bambang Oetomo, S.; Feijs, L.M.G.

    2009-01-01

    Health monitoring is crucial for the survival of the ill and fragile infants admitted at the neonatal intensive care unit (NICU) in a hospital. However, the adhesive electrodes and wires cause discomfort to the patients and hamper the parent-child interaction. In this paper, we propose the

  20. The development of the operational program for seismic monitoring system of Uljin Unit 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.R.; Heo, T.Y.; Cho, B.H. [Korea Electric Power Research Institute, Taejeon (Korea, Republic of); Kang, T.G.; Kim, H.M.; Kim, Y.S.; Oh, S.M.; Kang, Y.S. [Korea Electric Power Data Network Co., Seoul (Korea, Republic of)

    1997-12-31

    Due to aging of the imported seismic monitoring system of Uljin of t 1 and 2 units it is difficult for this system to provide enough functions needed for the security of seismic safety and the evaluation of the earthquake data from the seismic instrumentation. For this reason, it is necessary to replace the seismic monitoring system of Uljin 1 and 2 units with a new system which has the localized and upgraded hardware and corresponding software. In the part of standardization of existing seismic monitoring system, furthermore, it is necessary to develop the seismic wave analysis system which incorporate newly developed software and can real-timely analyze the seismic wave. This report is the finial product of research project ``The development of the operational program for seismic monitoring system of Uljin Unit 1 and 2`` which have been performed from June 1996 to June 1997 by KEPRI and KDN. Main accomplishments - Review of regulatory criteria for seismic monitoring system -Analysis and upgrade of hardware system -Analysis and upgrade of software system - Development of seismic wave analysis system. (author). 17 refs., 49 figs., 6 tabs.

  1. Burrow characteristics of the co-existing sibling species Mus booduga and Mus terricolor and the genetic basis of adaptation to hypoxic/hypercapnic stress

    Directory of Open Access Journals (Sweden)

    Narayan Gopeshwar

    2009-04-01

    Full Text Available Abstract Background The co-existing, sibling species Mus booduga and Mus terricolor show a difference in site-preference for burrows. The former build them in flat portion of the fields while the latter make burrows in earthen mounds raised for holding water in cultivated fields. In northern India which experiences great variation in climatic condition between summer and winter, M. booduga burrows have an average depth of 41 cm, as against 30 cm in southern India with less climatic fluctuation. M. terricolor burrows are about 20 cm deep everywhere. The three chromosomal species M. terricolor I, II and III have identical burrows, including location of the nest which is situated at the highest position. In contrast, in M. booduga burrows, the nest is at the lowest position. Results The nest chamber of M. booduga is located at greater depth than the nest chamber of M. terricolor. Also, in the burrows of M. booduga the exchange of air takes place only from one side (top surface in contrast to the burrows of M. terricolor where air exchange is through three sides. Hence, M. booduga lives in relatively more hypoxic and hypercapnic conditions than M. terricolor. We observed the fixation of alternative alleles in M. booduga and M. terricolor at Superoxide dismutase-1 (Sod-1, Transferrin (Trf and Hemoglobin beta chain (Hbb loci. All the three are directly or indirectly dependent on oxygen concentration for function. In addition to these, there are differences in burrow patterns and site-preference for burrows suggesting difference in probable adaptive strategy in these co-existing sibling species. Conclusion The burrow structure and depth of nest of the chromosomal species M. terricolor I, II and III are same everywhere probably due to the recency of their evolutionary divergence. Moreover, there is lack of competition for the well-adapted 'microhabitats' since they are non-overlapping in distribution. However, the co-existing sibling species M. booduga

  2. EFEK ANTIFERTILITAS EKSTRAK AKAR SOM JAWA (Talinum paniculatum Gaertn. PADA MENCIT (Mus musculus L. JANTAN

    Directory of Open Access Journals (Sweden)

    Tetri Widiyani

    2012-10-01

    Full Text Available Talinum paniculatum Gaertn commonly is used as aphrodisiac herb. Phytosterol, saponin, flavonoid and tannin of the herb have a certain bioactivity and may affect to the body system. The objective of this research was to examine the antifertility effects of sam jawa (Talinum paniculatum Gaertn. root extract (SJRE on male mice (Mus musculus L.. Twenty male mice were divided into 4 groups randomly with 5 replications. SJRE was dissolved in aquadest and given orally everyday for 34 days. The treatment dosages were 0 (control, 100,200, and 300 mg/kg BW. At 35th day mice were sacrificed and sectioned to remove testes and epididymis spermatozoas. Testes were sectioned using paraffin method and stained using Haematoxyllin-Eosin. Spermatogenic cells in each seminiferous tubule were counted to investigated spermatogenesis activity of testes. Epididymis sperm suspension was used to investigate sperm quality i.e: morphology, velocity and motility. Quantitatives data were analized using ANOVA and continued DMRT on 5% significance level. The result showed SJRE had antifertility effects on male mice (Mus musculus L. could inhibit spermatogenesis (decrease the spermatogenic cells count and decrease the sperm quality (increase percentage of abnormal sperm, decrease sperm motility and also decrease sperm velocity.

  3. Pan-African phylogeny of Mus (subgenus Nannomys) reveals one of the most successful mammal radiations in Africa

    Czech Academy of Sciences Publication Activity Database

    Bryja, Josef; Mikula, Ondřej; Šumbera, R.; Meheretu, Y.; Aghová, Tatiana; Lavrenchenko, L. A.; Mazoch, Vladimír; Oguge, N.; Mbau, J. S.; Welegerima, K.; Amundala, N.; Colyn, M.; Leirs, H.; Verheyen, E.

    2014-01-01

    Roč. 14, č. 256 (2014), s. 256 ISSN 1471-2148 R&D Projects: GA ČR GAP506/10/0983 Institutional support: RVO:68081766 Keywords : Biogeography * Tropical Africa * Molecular phylogeny * Pygmy mice * Plio-Pleistocene climatic fluctuations * Divergence timing * Muridae (Murinae) * Mus minutoides * Phylogeography * DNA barcoding Subject RIV: EG - Zoology Impact factor: 3.368, year: 2014

  4. GAMBARAN HEMATOLOGI MENCIT (Mus musculus MODEL TOKSISITAS SUBKRONIS

    Directory of Open Access Journals (Sweden)

    Ita Nur Eka Pujiastuti

    2017-06-01

    Full Text Available Garlic commonly is consumed as medicine to prevent or heal illness or to maintain someone's health. Many societies prefer garlic (Allium sativum among other herbal remedies for cholesterol treatment. It consists of several types, and one of them is single bulb garlic used to treat hypertension. There has been, however, no published research reporting the toxicological properties of single bulb garlic. The purpose of this study was to determine subchronic toxic effects of single bulb garlic administered to mice using hematological parameters. The experiment parameters were hemoglobin and hematocrit levels, the number of erythrocytes and leukocytes. Male mice (Mus musculus strain Balb-C were treated with single bulb garlic extract for 28 days with dosage levels of 0% (N , 0.25% (P1 , 0.5% (P2 , 1% (P3 , and 2% (P4 . Single bulb garlic showed no effect on hemoglobin and hematocrit levels but increased the number of erythrocyte and leucocyte. We concluded that single bulb garlic did not cause subchronic toxic effects.

  5. Acoustic emission monitoring of preservice testing at Watts Bar Unit 1 Nuclear Reactor

    International Nuclear Information System (INIS)

    Hutton, P.H.; Pappas, R.A.; Friesel, M.A.

    1985-02-01

    Acoustic emission (AE) monitoring of selected pressure boundary areas at TVA's Watts Bar, Unit 1 Nuclear Plant in the US during hot functional preservice testing is described. Background, methodology, and results are included. The work discussed here is a major milestone in a program supported by the US NRC to develop and demonstrate application of AE monitoring for continuous surveillance of reactor pressure boundaries to detect and evaluate growing flaws. The subject work demonstrated that anticipated problem areas can be overcome. Work is continuing to AE monitoring during reactor operation. 3 refs., 6 figs

  6. Mainstream end-tidal carbon dioxide monitoring in the neonatal intensive care unit.

    Science.gov (United States)

    Rozycki, H J; Sysyn, G D; Marshall, M K; Malloy, R; Wiswell, T E

    1998-04-01

    Continuous noninvasive monitoring of arterial carbon dioxide (CO2) in neonatal intensive care unit (NICU) patients would help clinicians avoid complications of hypocarbia and hypercarbia. End-tidal CO2 monitoring has not been used in this population to date, but recent technical advances and the introduction of surfactant therapy, which improves ventilation-perfusion matching, might improve the clinical utility of end-tidal monitoring. To determine the accuracy and precision of end-tidal CO2 monitoring in NICU patients. Nonrandomized recording of simultaneous end-tidal and arterial CO2 pairs. Two university NICUs. Forty-five newborn infants receiving mechanical ventilation who had indwelling arterial access, and a predefined subsample of infants who were NICU patients is as accurate as capillary or transcutaneous monitoring but less precise than the latter. It may be useful for trending or for screening patients for abnormal arterial CO2 values.

  7. 40 CFR 75.81 - Monitoring of Hg mass emissions and heat input at the unit level.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring of Hg mass emissions and... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Hg Mass Emission Provisions § 75.81 Monitoring of Hg mass emissions and heat input at the unit level. The owner or operator of the...

  8. Transformative Poetry : A Case Study of W.H. Auden's Musée des Beaux Arts And General Conclusions

    NARCIS (Netherlands)

    Sarot, Marcel

    2016-01-01

    This article situates Auden’s poem Musée des Beaux Arts in the process of his conversion to Christianity. The author argues for the layered intertextuality of the poem, in which allusions to Bruegel’s Landscape with the Fall of Icarus, The Census at Jerusalem, and The Massacre of the Innocents can

  9. La stratégie numérique du musée de la Civilisation

    OpenAIRE

    Baz, Ana-Laura

    2016-01-01

    Après une description des orientations déployées dans la mise en œuvre de la stratégie numérique du musée de la Civilisation à Québec, l’auteur dresse un premier bilan de l’opération, de ses succès et de ses échecs, constatant que beaucoup reste à faire pour mesurer les retombées de cette stratégie sur la participation citoyenne et le comportement des internautes.

  10. Corrected placement of Mus-Rattus fossil calibration forces precision in the molecular tree of rodents

    OpenAIRE

    Kimura, Yuri; Hawkins, Melissa T. R.; McDonough, Molly M.; Jacobs, Louis L.; Flynn, Lawrence J.

    2015-01-01

    Time calibration derived from the fossil record is essential for molecular phylogenetic and evolutionary studies. Fossil mice and rats, discovered in the Siwalik Group of Pakistan, have served as one of the best-known fossil calibration points in molecular phylogenic studies. Although these fossils have been widely used as the 12 Ma date for the Mus/Rattus split or a more basal split, conclusive paleontological evidence for the nodal assignments has been absent. This study analyzes newly reco...

  11. The effect of electron beam radiations on testicular damage in mice, Mus musculus

    International Nuclear Information System (INIS)

    Vikram, S.; Nair, Vijay Mala Grover

    2013-01-01

    Adult male Swiss albino mice, Mus musculus (8-10 weeks old) weighing 28±2.5 gm were exposed to varying doses (2-12 Gy) of electron beam radiations and maintained in animal house at 26-28 C. The animals were sacrificed following 35 and 60 days following exposure to electron beam radiations. The LD-50 value, change in the weight and histological details of the testis, sperm count, sperm shape abnormalities and sperm motility were recorded. The data suggests that electron beam radiations is a potential inducer to cause reproductive system dysfunctions which probably may be responsible leading to infertility. (author)

  12. Relation between location of a motor unit in the human biceps brachii and its critical firing levels for different tasks

    NARCIS (Netherlands)

    Gielen, C.C.A.M.; Haar Romeny, B.M. ter; Gon, J.J.D. van der

    1984-01-01

    Critical firing levels (CFLs) of single motor units (MUs) in the long head of the human biceps brachii muscle were determined in combinations of two isometric tasks: flexion of the elbow, supination of the lower arm, and exorotation of the humerus, as well as the corresponding antagonistic tasks.

  13. Electronic monitoring and voice prompts improve hand hygiene and decrease nosocomial infections in an intermediate care unit.

    Science.gov (United States)

    Swoboda, Sandra M; Earsing, Karen; Strauss, Kevin; Lane, Stephen; Lipsett, Pamela A

    2004-02-01

    To determine whether electronic monitoring of hand hygiene and voice prompts can improve hand hygiene and decrease nosocomial infection rates in a surgical intermediate care unit. Three-phase quasi-experimental design. Phase I was electronic monitoring and direct observation; phase II was electronic monitoring and computerized voice prompts for failure to perform hand hygiene on room exit; and phase III was electronic monitoring only. Nine-room, 14-bed intermediate care unit in a university, tertiary-care institution. All patient rooms, utility room, and staff lavatory were monitored electronically. All healthcare personnel including physicians, nurses, nursing support personnel, ancillary staff, all visitors and family members, and any other personnel interacting with patients on the intermediate care unit. All patients with an intermediate care unit length of stay >48 hrs were followed for nosocomial infection. Electronic monitoring during all phases, computerized voice prompts during phase II only. We evaluated a total of 283,488 electronically monitored entries into a patient room with 251,526 exits for 420 days (10,080 hrs and 3,549 patient days). Compared with phase I, hand hygiene compliance in patient rooms improved 37% during phase II (odds ratio, 1.38; 95% confidence interval, 1.04-1.83) and 41% in phase III (odds ratio, 1.41; 95% confidence interval, 1.07-1.84). When adjusting for patient admissions during each phase, point estimates of nosocomial infections decreased by 22% during phase II and 48% during phase III; when adjusting for patient days, the number of infections decreased by 10% during phase II and 40% during phase III. Although the overall rate of nosocomial infections significantly decreased when combining phases II and III, the association between nosocomial infection and individual phase was not significant. Electronic monitoring provided effective ongoing feedback about hand hygiene compliance. During both the voice prompt phase and post

  14. Electrical - light current remote monitoring, control and automation. [Coal mine, United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Collingwood, C H

    1981-06-01

    A brief discussion is given of the application of control monitoring and automation techniques to coal mining in the United Kingdom, especially of the use of microprocessors, for the purpose of enhancing safety and productivity. Lighting systems for the coal mine is similarly discussed.

  15. The Evolving Contingency Contracting Market: Private Sector Self regulation and United States Government Monitoring of Procurement of Stability Operations Services

    Science.gov (United States)

    2016-01-01

    statements of work would be useful in ensuring ethical govern- ment procurement practices. Conclusions The United States conducts diplomatic, defense...THE EVOLVING CONTINGENCY CONTRACTING MARKET: PRIVATE SECTOR SELF-REGULATION AND UNITED STATES GOVERNMENT MONITORING OF PROCUREMENT OF STABILITY...MARKET: PRIVATE SECTOR SELF-REGULATION AND UNITED STATES GOVERNMENT MONITORING OF PROCUREMENT OF STABILITY OPERATIONS SERVICES Whitney Grespin January

  16. Assessing altered motor unit recruitment patterns in paretic muscles of stroke survivors using surface electromyography

    Science.gov (United States)

    Hu, Xiaogang; Suresh, Aneesha K.; Rymer, William Z.; Suresh, Nina L.

    2015-12-01

    Objective. The advancement of surface electromyogram (sEMG) recording and signal processing techniques has allowed us to characterize the recruitment properties of a substantial population of motor units (MUs) non-invasively. Here we seek to determine whether MU recruitment properties are modified in paretic muscles of hemispheric stroke survivors. Approach. Using an advanced EMG sensor array, we recorded sEMG during isometric contractions of the first dorsal interosseous muscle over a range of contraction levels, from 20% to 60% of maximum, in both paretic and contralateral muscles of stroke survivors. Using MU decomposition techniques, MU action potential amplitudes and recruitment thresholds were derived for simultaneously activated MUs in each isometric contraction. Main results. Our results show a significant disruption of recruitment organization in paretic muscles, in that the size principle describing recruitment rank order was materially distorted. MUs were recruited over a very narrow force range with increasing force output, generating a strong clustering effect, when referenced to recruitment force magnitude. Such disturbances in MU properties also correlated well with the impairment of voluntary force generation. Significance. Our findings provide direct evidence regarding MU recruitment modifications in paretic muscles of stroke survivors, and suggest that these modifications may contribute to weakness for voluntary contractions.

  17. Application for verification of monitor units of the treatment planning system

    International Nuclear Information System (INIS)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-01-01

    Current estimates algorithms achieve acceptable degree of accuracy. However, operate on the basis of un intuitive models. It is therefore necessary to verify the calculation of monitor units of the treatment planning system (TPS) with those obtained by other independent formalisms. To this end, we have developed an application based on factorization formalism that automates the calculation of dose.

  18. Measurement of the dosimetric parameters for low monitor units in step-and-shoot IMRT delivered by Siemens Artiste linear accelerators; Medida de los parametros dosimetricos para bajo numero de unidades monitor en IMRT segmentada estatica administrada por aceleradores lineales Siemens Artiste

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Lopez Fernandez, A.; Saez Beltran, M.; Martin Martin, G.; Alonso Iracheta, L.

    2012-07-01

    Absorbed dose linearity and beam stability, both for low monitor units, are important factors for ensuring planned dose delivery in step-and-shoot IMRT. For Siemens Artiste linear accelerators, under IMRT stable irradiation conditions and for a single segment of 20 cm x 20 cm field size, the linearity of the absorbed dose with the monitor units, field flatness and symmetry have been measured for the range between 1 and 10 monitor units. We have found that absorbed dose linearity with monitor units is within 2% down to 2 monitor units and it is about 9% for 1 monitor unit. Flatness and symmetry values show variations within 1% down to 2 monitor units and increase by 9% for lower values. Using our monitor unit distribution per segment in IMRT we estimate that the uncertainty in absorbed dose for a whole treatment due to these factors is less than 1% (k= 3). (Author) 13 refs.

  19. Sampling and Analysis Plan Update for Groundwater Monitoring 1100-EM-1 Operable Unit

    International Nuclear Information System (INIS)

    DR Newcomer

    1999-01-01

    This document updates the sampling and analysis plan (Department of Energy/Richland Operations--95-50) to reflect current groundwater monitoring at the 1100-EM-1Operable Unit. Items requiring updating included sampling and analysis protocol, quality assurance and quality control, groundwater level measurement procedure, and data management. The plan covers groundwater monitoring, as specified in the 1993 Record of Decision, during the 5-year review period from 1995 through 1999. Following the 5-year review period, groundwater-monitoring data will be reviewed by Environmental Protection Agency to evaluate the progress of natural attenuation of trichloroethylene. Monitored natural attenuation and institutional controls for groundwater use at the inactive Horn Rapids Landfill was the selected remedy specified in the Record of Decision

  20. Methylation patterns of repetitive DNA sequences in germ cells of Mus musculus.

    Science.gov (United States)

    Sanford, J; Forrester, L; Chapman, V; Chandley, A; Hastie, N

    1984-03-26

    The major and the minor satellite sequences of Mus musculus were undermethylated in both sperm and oocyte DNAs relative to the amount of undermethylation observed in adult somatic tissue DNA. This hypomethylation was specific for satellite sequences in sperm DNA. Dispersed repetitive and low copy sequences show a high degree of methylation in sperm DNA; however, a dispersed repetitive sequence was undermethylated in oocyte DNA. This finding suggests a difference in the amount of total genomic DNA methylation between sperm and oocyte DNA. The methylation levels of the minor satellite sequences did not change during spermiogenesis, and were not associated with the onset of meiosis or a specific stage in sperm development.

  1. 24 CFR 882.123 - Conversion of Section 23 Units to Section 8 and Section 23 monitoring.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Conversion of Section 23 Units to... Applicability, Scope and Basic Policies § 882.123 Conversion of Section 23 Units to Section 8 and Section 23 monitoring. (a)-(d) [Reserved] (e) Section 23 policies for units planned for conversion on or before...

  2. Current practice and recommendations in UK epilepsy monitoring units. Report of a national survey and workshop.

    Science.gov (United States)

    Hamandi, Khalid; Beniczky, Sandor; Diehl, Beate; Kandler, Rosalind H; Pressler, Ronit M; Sen, Arjune; Solomon, Juliet; Walker, Matthew C; Bagary, Manny

    2017-08-01

    Inpatient video-EEG monitoring (VEM) is an important investigation in patients with seizures or blackouts, and in the pre-surgical workup of patients with epilepsy. There has been an expansion in the number of Epilepsy Monitoring Units (EMU) in the UK offering VEM with a necessary increase in attention on quality and safety. Previous surveys have shown variation across centres on issues including consent and patient monitoring. In an effort to bring together healthcare professionals in the UK managing patients on EMU, we conducted an online survey of current VEM practice and held a one-day workshop convened under the auspices of the British Chapter of the ILAE. The survey and workshop aimed to cover all aspects of VEM, including pre-admission, consent procedures, patient safety, drug reduction and reinstatement, seizure management, staffing levels, ictal testing and good data recording practice. This paper reports on the findings of the survey, the workshop presentations and workshop discussions. 32 centres took part in the survey and there were representatives from 22 centres at the workshop. There was variation in protocols, procedures and consent processes between units, and levels of observation of monitored patients. Nevertheless, the workshop discussion found broad areas of agreement on points. A survey and workshop of UK epilepsy monitoring units found that some variability in practice is inevitable due to different local arrangements and patient groups under investigation. However, there were areas of clear consensus particularly in relation to consent and patient safety that can be applied to most units and form a basis for setting minimum standards. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  3. In-core monitor housing replacement at Fukushima Daiichi Unit No.4

    International Nuclear Information System (INIS)

    Arai, Tomoyuki

    1999-01-01

    The in-core monitor (ICM) housing replacement of a Boiling Water Reactor (BWR) has been completed at Fukushima-Daiichi Unit No. 4 (1F4) of the Tokyo Electric Power Company (TEPCO) in Japan. Since cracking of the inside surface of an ICM housing was found in this unit, the ICM housing was replaced with one made of low-carbon stainless steel (SS) to improve Intergranular Stress Corrosion Cracking (IGSCC) resistance. This project is the first application of the replacement procedure for the ICM housing and employs various advanced technologies. The outline of the ICM housing replacement project and applied technologies are discussed in this paper. (author)

  4. A geometric morphometric analysis of the shape of the first upper molar in mice of the genus Mus (Muridae, Rodentia)

    Czech Academy of Sciences Publication Activity Database

    Macholán, Miloš

    2006-01-01

    Roč. 270, č. 4 (2006), s. 672-681 ISSN 0952-8369 R&D Projects: GA AV ČR IAA6045307 Institutional research plan: CEZ:AV0Z50450515 Keywords : Mus * geometric morphometrics * thin-plate spline Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.413, year: 2006

  5. Teratogenic effect of yogurt in mice fetus (Mus musculus

    Directory of Open Access Journals (Sweden)

    Dwisari Dillasamola

    2018-04-01

    Full Text Available Yogurt is one of the dairy products made from lactic acid fermentation by using Lactobacillus bulgaricus and Streptococcus thermophilus. A study on teratogenic effects of yogurt on the white female mice fetus (Mus musculus has been carried out. Pregnant mice used were 20 which divided into 4 groups : the control group, D1, D2, and D3. The treatments giveThe mice were Distidelled water (control, 0.52 yogurt (D1, 1.04  yogurt (D2, and 2.08 g yogurt (D3. Data were analyzed using one-way ANOVA followed by Duncan multiple range test. Results showed that administration of yogurt during pregnancy could affect mother body weight of mice (P 0,05. Observations with Alizarin solution did not show skeletal defects in comparison to the control group. Observations with Bouin’s solution showed defective visceral cleft palate in fetal mice yogurt group D3. This study conclude that yogurt is safe to consume in groups D1 and D2. Yogurt has the potential to cause fetal teratogenic in group D3

  6. Microcontroller based four-channel current readout unit for beam slit monitor

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    This paper describes the design and development of a microcontroller based four-channel current readout unit for Beam Slit Monitor (BSM) installed in Transport Line-1 of Indus Accelerator Complex. BSM is a diagnostic device consisting of two horizontal and two vertical blades, which can be moved independently in to the beam pipe to cut the beam transversely. The readout unit employs switched integrators with reset, hold and select switches and timing and control unit. It integrates the current output of the four blades of BSM and produces an output corresponding to the beam charge intercepted by the blade. The integrator outputs are then multiplexed and digitized using 12-bit ADC. Acquired digital data from ADC is stored into on-chip RAM of the microcontroller. The readout sequence is synchronized with the Microtron beam-timing signal. The timing of integration, hold and reset cycles is controlled by the microcontroller. The unit is connected on a serial link to the host computer in main control room. This unit has been integrated with the BSM system and is being used to obtain the electron beam profile. (author)

  7. MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT (MCU) GAMMA MONITORS SYSTEM FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Casella, V

    2005-12-15

    The Department of Energy (DOE) selected Caustic-Side Solvent Extraction (CSSX) as the preferred technology for the removal of radioactive cesium from High-Level Waste (HLW) at the Savannah River Site (SRS). Before the full-scale Salt Waste Processing Facility (SWPF) becomes operational, the Closure Business Unit (CBU) plans to process a portion of dissolved saltcake waste through a Modular CSSX Unit (MCU). This work was derived from Technical Task Request SP-TTR-2004-00013, ''Gamma Monitor for MCU''. The deliverables for this task are the hardware and software for the gamma monitors and a report summarizing the testing and acceptance of this equipment for use in the MCU. Gamma-ray monitors are required to: (1) Measure the Cs-137 concentration in the decontaminated salt solution before entering the DSS (Decontaminated Salt Solution) Hold Tank, (2) Measure the Cs-137 concentration in the strip effluent before entering the Strip Effluent Hold Tank, (3) Verify proper operation of the solvent extraction system by verifying material balance within the process (The DSS Hold Tank Cs-137 concentration will be very low and the Cs-137 concentration in the Strip Effluent Hold Tank will be fifteen times higher than the Cs-137 concentration in the Feed Tank.) Sodium iodide monitors are used to measure the Cs-137 concentration in the piping before the DSS Hold tank, while GM monitors are used for Cs-137 measurements before the Strip Effluent Hold Tank. Tungsten shields were designed using Monte Carlo calculations and fabricated to reduce the process background radiation at the detector positions. These monitors were calibrated with NIST traceable standards that were specially made to be the same as the piping being monitored. Since this gamma ray monitoring system is unique, specially designed software was written and acceptance tested by Savannah River National Laboratory personnel. The software is a LabView-based application that serves as a unified

  8. MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT (MCU) GAMMA MONITORS SYSTEM FINAL REPORT

    International Nuclear Information System (INIS)

    Casella, V

    2005-01-01

    The Department of Energy (DOE) selected Caustic-Side Solvent Extraction (CSSX) as the preferred technology for the removal of radioactive cesium from High-Level Waste (HLW) at the Savannah River Site (SRS). Before the full-scale Salt Waste Processing Facility (SWPF) becomes operational, the Closure Business Unit (CBU) plans to process a portion of dissolved saltcake waste through a Modular CSSX Unit (MCU). This work was derived from Technical Task Request SP-TTR-2004-00013, ''Gamma Monitor for MCU''. The deliverables for this task are the hardware and software for the gamma monitors and a report summarizing the testing and acceptance of this equipment for use in the MCU. Gamma-ray monitors are required to: (1) Measure the Cs-137 concentration in the decontaminated salt solution before entering the DSS (Decontaminated Salt Solution) Hold Tank, (2) Measure the Cs-137 concentration in the strip effluent before entering the Strip Effluent Hold Tank, (3) Verify proper operation of the solvent extraction system by verifying material balance within the process (The DSS Hold Tank Cs-137 concentration will be very low and the Cs-137 concentration in the Strip Effluent Hold Tank will be fifteen times higher than the Cs-137 concentration in the Feed Tank.) Sodium iodide monitors are used to measure the Cs-137 concentration in the piping before the DSS Hold tank, while GM monitors are used for Cs-137 measurements before the Strip Effluent Hold Tank. Tungsten shields were designed using Monte Carlo calculations and fabricated to reduce the process background radiation at the detector positions. These monitors were calibrated with NIST traceable standards that were specially made to be the same as the piping being monitored. Since this gamma ray monitoring system is unique, specially designed software was written and acceptance tested by Savannah River National Laboratory personnel. The software is a LabView-based application that serves as a unified interface for controlling

  9. Taming of the monitors: reducing false alarms in intensive care units

    Czech Academy of Sciences Publication Activity Database

    Plešinger, Filip; Klimeš, Petr; Halámek, Josef; Jurák, Pavel

    2016-01-01

    Roč. 37, č. 8 (2016), s. 1313-1325 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2034; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : ECG * critical care * arrhythmia * intensive care unit * ICU monitor * false alarm * beat detection Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 2.058, year: 2016

  10. Motor unit number index (MUNIX) derivation from the relationship between the area and power of surface electromyogram: a computer simulation and clinical study

    Science.gov (United States)

    Miralles, Francesc

    2018-06-01

    Objective. The motor unit number index (MUNIX) is a technique based on the surface electromyogram (sEMG) that is gaining acceptance as a method for monitoring motor neuron loss, because it is reliable and produces less discomfort than other electrodiagnostic techniques having the same intended purpose. MUNIX assumes that the relationship between the area of sEMG obtained at increasing levels of muscle activation and the values of a variable called ‘ideal case motor unit count’ (ICMUC), defined as the product of the ratio between area and power of the compound muscle action potential (CMAP) by that of the sEMG, is described by a decreasing power function. Nevertheless, the reason for this comportment is unknown. The objective of this work is to investigate if the definition of MUNIX could derive from more basic properties of the sEMG. Approach. The CMAP and sEMG epochs obtained at different levels of muscle activation from (1) the abductor pollicis brevis (APB) muscle of persons with and without a carpal tunnel syndrome (CTS) and (2) from a computer model of sEMG generation previously published were analysed. Main results. MUNIX reflects the power relationship existing between the area and power of a sEMG. The exponent of this function was smaller in patients with motor CTS than in the rest of the subjects. The analysis of the relationship between the area and power of a sEMG could aid in distinguishing a MUNIX reduction due to a motoneuron loss from that due to a loss of muscle fibre. Significance. MUNIX is derived from the relationship between the area and power of a sEMG. This relationship changes when there is a loss of motor units (MUs), which partially explains the diagnostic sensibility of MUNIX. Although the reasons for this change are unknown, it could reflect an increase in the proportion of MUs of great amplitude.

  11. Mobile units for monitoring of radiation situation

    International Nuclear Information System (INIS)

    Drabova, D.; Filgas, R.; Cespirova, I.

    1995-01-01

    For the radiation monitoring network of the Czech Republic a prototype of the small system for dose rate measurements and nuclide activity estimates suitable for use in mobile units was designed and tested in National Radiation Protection Institute. The system consists of high purity Ge detector, multichannel analyzer, high pressure ionization chamber or proportional counter and portable computer working in multitask mode for storing and evaluating of the spectra as well as dose rate handling, recording, storing and searching and presentation. The information about actual position is provided by the global positioning system Garmin on-line connected to the computer. This information is used later on to create the maps of contamination using small desktop mapping (GIS) system. The system is designed to be used in measurements on foot, in car, with helicopter or small fixed wing aircraft. (J.K.)

  12. Le corps numérique des données The Digital Body of Data: the Transfer of Artefact Fact Sheets from the Museum of Man to the Musée du quai Branly

    Directory of Open Access Journals (Sweden)

    Tiziana Nicoletta Beltrame

    2012-05-01

    Full Text Available Le transfert des collections extra-européennes du musée de l’Homme au musée du quai Branly implique le déplacement des informations documentaires sur les objets. Des différentes fiches en papier (de collection ou d’inventaire, descriptive de l’objet, méthodique créées et classées au sein des départements du musée de l’Homme, on passe à la fiche informatique « TMS objets » au musée du quai Branly. L’information ne change pas simplement de place et de matière, elle est reconfigurée dans de nouvelles articulations du savoir sur les collections. L’inventaire muséal est ici conçu comme le système qui matérialise un savoir structuré. Pour pouvoir analyser ce système, il faut mettre en relation les propriétés des documents et les modalités de leur classement dans un espace créé ad hoc. La matérialité des supports, les multiples possibilités de rangements et de création de liens (la mise en relations entre rubriques de la fiche informatique agissent sur le contenu des données et ouvrent ainsi de nouvelles voies pour la construction du savoir.The transfer of extra-European collections from the Museum of Man to the Musée du quai Branly involves the displacement of documentary information on the artefacts. The various paper files (on collections or inventory, descriptive of the object, methodological created and classified within different departments of the Museum of Man are being replaced by digital files, or “TMS objects”, at the Musée du quai Branly. The information is not simply changing its location and material, it is being reconfigured within new interconnections of knowledge on the collections. The museum inventory is here conceived as the system that materialises a structured knowledge. To be able to analyse this system, it is necessary to link the documents’ properties to the methods used to classify them in an ad hoc space. The materiality of the media, the multiple possibilities for

  13. Test of Fruit Extract Pare (Momordica charantia L.) to Quality of Ejaculated Spermatozoa Mice (Mus musculus L.)

    Science.gov (United States)

    Fifendy, M.; Indriati, G.

    2018-04-01

    Pare (Momordica charantia L.) can be used in the treatment of various diseases, such as influenza, cancer, anti-inflammatory, anti-HIV, antimitotic and antifertilitas. This study aimed to determine the effect of the herbal bitter (Momordica charantia L.) to ejaculated sperm quality mice (Mus musculus L.). This research was conducted using Completely Randomized Design (CRD) with 4 treatments and 6 replications, water and fed adlibitum. First treatment is given solvent extract. Second treatments extract were given 0.2 gram, third treatment were given 0.4 gram of extracts and fourth treatment were treated exstrac 0.6 gram were orally for 30 days. After the mice decapitated, dissected and take sperm from vas deferens. Then, the sperm preparation determined using the improved Neubauer. Data were analyzed by ANOVA (Analysis of Varians). The results shoured at doses of 0,2 gram, the average sperm count was 19.89. decrease significant when compared with the control in which the average number of sperm 29.13. So with this research the effective doses to decrease sperm count and can be used as a contraception medication dosage was 0,2 gram. It can be conclude that the extract of bitter (Momordica charantia L.) can decrease the quality of the ejaculated sperm of mice (Mus musculus L.)

  14. Development of a unit suitable for corrosion monitoring in district heating systems. Experiences with the LOCOR-cell test method

    DEFF Research Database (Denmark)

    Andersen, Asbjørn; Hilbert, Lisbeth Rischel

    2004-01-01

    A by-pass unit suitable for placement of a number of different probes for corrosion monitoring has been designed. Also measurements of water parameters are allowed in a side stream from the unit. The project is a part of the Nordic Innovation Fund project KORMOF. The by-pass unit has been installed...... in 6 pressurised circulating heating systems and in one cooling system. 7 different corrosion monitoring methods have been used to study corrosion rates and types in dependency of water chemistry. This paper describes the design of the by-pass unit including water analysis methods. It also describes...... the purpose, background and gained results of one of the used monitoring techniques, the crevice corrosion measurements obtained by the LOCOR-Cell„§. The crevice corrosion cell was developed by FORCE Technology in a previous district heating project financed by Nordic Industrial Fund (1)(2). Results from...

  15. Development and verification of an excel program for calculation of monitor units for tangential breast irradiation with external photon beams

    International Nuclear Information System (INIS)

    Woldemariyam, M.G.

    2015-07-01

    The accuracy of MU calculation performed with Prowess Panther TPS (for Co-60) and Oncentra (for 6MV and 15MV x-rays) for tangential breast irradiation was evaluated with measurements made in an anthropomorphic phantom using calibrated Gafchromic EBT2 films. Excel programme which takes in to account external body surface irregularity of an intact breast or chest wall (hence absence of full scatter condition) using Clarkson’s sector summation technique was developed. A single surface contour of the patient obtained in a transverse plane containing the MU calculation point was required for effective implementation of the programme. The outputs of the Excel programme were validated with the respective outputs from the 3D treatment planning systems. The variations between the measured point doses and their calculated counterparts by the TPSs were within the range of -4.74% to 4.52% (mean of -1.33% and SD of 2.69) for the prowess panther TPS and -4.42% to 3.14% (mean of -1.47% and SD of -3.95) for the Oncentra TPS. The observed degree of deviation may be attributed to limitations of the dose calculation algorithm within the TPSs, set up inaccuracies of the phantom during irradiation and inherent uncertainties associated with radiochromic film dosimetry. The percentage deviations between MUs calculated with the two TPSs and the Excel program were within the range of -3.45% and 3.82% (mean of 0.83% and SD of 2.25). The observed percentage deviations are within the 4% action level recommended by TG-114. This indicates that the Excel program can be confidently employed for calculation of MUs for 2D planned tangential breast irradiations or to independently verify MUs calculated with another calculation methods. (au)

  16. The Vibration Monitoring of the Gascompressor Units with Application of Hurst's Statistics

    International Nuclear Information System (INIS)

    Zakharov, O V; Novichkov, S V; Kochetkov, A V

    2016-01-01

    The gascompressor units work in the unsteady regime which depends on many internal and external factors. For the solution of problems of control, management and forecasting the statistical assessment of a condition of object in real time according to noisy observations of one realization of stochastic process is carried out. The traditional spectral analysis on the basis of Fast Fourier Transformation in this case is inefficient if time scale is much less than duration, which is subject to the analysis. Therefore for monitoring of a condition of the equipment it is offered to use Hurst's statistics by means of which it is possible to investigate quantitatively law of development of a vibration signal and unambiguously to analyze a condition of the gascompressor units. Calculation of economic efficiency from introduction of such technology of monitoring will provide decrease on average by 2.5% of a consumption of gas and specific costs of capital repairs of the gascompressor units at the expense of increase in a total operating time by 20%. (paper)

  17. Assessment of volumetric-modulated arc therapy for constant and variable dose rates

    Directory of Open Access Journals (Sweden)

    Mariluz De Ornelas-Couto

    2017-01-01

    Full Text Available Purpose: The aim of this study is to compare the effects of dose rate on volumetric-modulated arc therapy plans to determine optimal dose rates for prostate and head and neck (HN cases. Materials and Methods: Ten prostate and ten HN cases were retrospectively studied. For each case, seven plans were generated: one variable dose rate (VDR and six constant dose rate (CDR (100–600 monitor units [MUs]/min plans. Prescription doses were: 80 Gy to planning target volume (PTV for the prostate cases, and 70, 60, and 54 Gy to PTV1, PTV2, and PTV3, respectively, for HN cases. Plans were normalized to 95% of the PTV and PTV1, respectively, with the prescription dose. Plans were assessed using Dose-Volume-Histogram metrics, homogeneity index, conformity index, MUs, and delivery time. Results: For the prostate cases, significant differences were found for rectum D35 between VDR and all CDR plans, except CDR500. Furthermore, VDR was significantly different than CDR100 and 200 for bladder D50. Delivery time for all CDR plans and MUs for CDR400–600 were significantly higher when compared to VDR. HN cases showed significant differences between VDR and CDR100, 500 and 600 for D2 to the cord and brainstem. Significant differences were found for delivery time and MUs for all CDR plans, except CDR100 for number of MUs. Conclusion: The most significant differences were observed in delivery time and number of MUs. All-in-all, the best CDR for prostate cases was found to be 300 MUs/min and 200 or 300 MUs/min for HN cases. However, VDR plans are still the choice in terms of MU efficiency and plan quality.

  18. Condition based monitoring, diagnosis and maintenance on operating equipments of a hydraulic generator unit

    International Nuclear Information System (INIS)

    Liu, X T; Feng, F Z; Si, A W

    2012-01-01

    According to performance characteristics of operating equipments in a hydraulic generator unit (HGU), the relative techniques on condition monitoring and fault diagnosis (CMFD) are introduced in this paper, especially the key technologies are emphasized, such as equipment monitoring, expert system (ES), intelligent diagnosis and condition based maintenance (CBM). Meanwhile, according to the instructor on CBM proposed by State electric power corporation, based on integrated mode, the main steps on implementation of CBM are discussed in this paper.

  19. Unit-based functional IDDT testing for aging degradation monitoring in a VLIW processor

    NARCIS (Netherlands)

    Zhao, Yong; Kerkhoff, Hans G.

    2015-01-01

    In this paper, functional unit-based IDDT testing has been applied for a 90nm VLIW processor to monitor its aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test-program development based on the

  20. Transformative Poetry. A Case Study of W. H. Auden’s Musée Des Beaux Arts and General Conclusions

    Directory of Open Access Journals (Sweden)

    Sarot Marcel

    2016-10-01

    Full Text Available This article situates Auden’s poem Musée des Beaux Arts in the process of his conversion to Christianity. The author argues for the layered intertextuality of the poem, in which allusions to Bruegel’s Landscape with the Fall of Icarus, The Census at Jerusalem, and The Massacre of the Innocents can be recognised. Moreover, Philippe de Champaigne’s Presentation in the Temple and Peter Paul Rubens’s The Martyrdom of St Livinus (in the same museum in Brussels seem also to have influenced the poem. Finally, there is reason to suppose that John Singer Sargent’s Crashed Aeroplane influenced Auden. In an analysis of the structure of the poem, the author argues that there is a clear structure hidden under the surface of day-to-day language. He connects this hidden structure with Auden’s poem The Hidden Law, and suggests that Auden wished to claim that even though we cannot understand suffering, it has a hidden meaning known only to God. This hidden meaning connects our suffering with the self-emptying of Christ, a connection which the author demonstrates is in fact also made in Musée des Beaux Arts.

  1. Embryo quality of mice (“Mus musculus” fed royal jelly Qualidade embrionária de camundongos ("Mus musculus" suplementados com geléia real

    Directory of Open Access Journals (Sweden)

    Bruno Edésio dos Santos Melo

    2009-03-01

    Full Text Available The study was carried out to verify the effect of feeding royal jelly associated to follicle growth induction on number and quality of mice (Mus musculus embryos. Sixty Swiss females ageing from eight to ten weeks were distributed into three treatments: the first one, composed by animals fed 0.2 mL of physiological solution intraperitoneal (control group, n=20; the second and third ones, composed by females fed 0.5 and 1.0 mg of royal jelly diluted in 0.2 mL of physiological solution (n=20, respectively. Royal jelly was administered during 15 days, followed by the follicular growth induction process. Embryos were collected 68 hours after mating, by uterine flushing. No treatment effects on the number of females that answered to superovulatory process, the number of total recovery structures, the number of viable and non viable structures and the morphological quality of viable embryos (P>0.05 were observed. Therefore, royal jelly doses used were not efficient to increase the number of embryos and to improve the quality recovery from superovulated mice.Objetivou-se verificar a influência da geléia real, associada ao tratamento de indução de crescimento folicular, no número e na qualidade de embriões de camundongos (Mus musculus. Foram utilizadas 60 fêmeas da linhagem Suíço albino com idade entre oito e dez semanas, distribuídas em três tratamentos: o primeiro, composto por animais que receberam 0,2 mL de solução fisiológica, via intraperitonial (grupo controle, n=20; o segundo e terceiro, compostos de fêmeas que receberam 0,5 e 1 mg de geléia real diluídos em 0,2 mL de solução fisiológica via intraperitonial (n=20, respectivamente. Foi administrada geléia real por um período de 15 dias, segundo o processo de indução do crescimento folicular. As coletas dos embriões ocorreram 68 horas após a cobertura, utilizando-se o método da lavagem uterina. Não houve diferença no número de fêmeas que responderam ao tratamento

  2. 2008 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-03-01

    This report presents the 2008 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site during fiscal year 2008. This is the second groundwater monitoring report prepared by DOE-LM for the CNTA.

  3. 2008 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    International Nuclear Information System (INIS)

    2009-01-01

    This report presents the 2008 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site during fiscal year 2008. This is the second groundwater monitoring report prepared by DOE-LM for the CNTA

  4. denV gene of bacteriophage T4 restores DNA excision repair to mei-9 and mus201 mutants of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Banga, S.S.; Boyd, J.B.; Valerie, K.; Harris, P.V.; Kurz, E.M.; de Riel, J.K.

    1989-01-01

    The denV gene of bacteriophage T4 was fused to a Drosophila hsp70 (70-kDa heat shock protein) promoter and introduced into the germ line of Drosophila by P-element-mediated transformation. The protein product of that gene (endonuclease V) was detected in extracts of heat-shocked transformants with both enzymological and immunoblotting procedures. That protein restores both excision repair and UV resistance to mei-9 and mus201 mutants of this organism. These results reveal that the denV gene can compensate for excision-repair defects in two very different eukayotic mutants, in that the mus201 mutants are typical of excision-deficient mutants in other organisms, whereas the mei-9 mutants exhibit a broad pleiotropism that includes a strong meiotic deficiency. This study permits an extension of the molecular analysis of DNA repair to the germ line of higher eukaryotes. It also provides a model system for future investigations of other well-characterized microbial repair genes on DNA damage in the germ line of this metazoan organism

  5. [Musical Inactivity - A Risk Factor? A Short Questionnaire to Assess Musical Activity (MusA)].

    Science.gov (United States)

    Fernholz, Isabel; Menzel, Juliane; Jabusch, Hans-Christian; Gembris, Heiner; Fischer, Felix; Kendel, Friederike; Kreutz, Gunter; Schmidt, Alexander; Willich, Stefan N; Weikert, Cornelia

    2018-02-27

    There is only a limited number of studies on associations between musical activity and health issues. It seems that musical activity has physiological and psychological benefits, as well as effects on the mental capacity, but this has been studied only in a few clinical and epidemiological studies. One reason might be that no appropriate survey instrument assessing musical activity is available. Here we provide an overview of survey instruments that assess musicality and musical activity. One focus is the presentation of a newly developed German questionnaire (MusA), which assesses musical activity (active music making and music reception) and was specifically developed for the "German National Cohort", a German health study. Through literature research, questionnaires were identified that assess musicality and / or musical activity. A new German questionnaire was developed from a panel of experts and tested in a small study (n=121, women and men age 18-70 years). In the literature research, 3 questionnaires were identified which focus on musicality and musical activity with different aspects (Gold-MSI, MUSE, MEQ). All 3 instruments may be characterized as large psychometric scales, which especially assess aspects of musicality in the English language. The Gold-MSI is additionally available in German. None of the existing questionnaires covers musical activities in detail. A new short German questionnaire consisting of 9 questions with a maximum filling time of 3-5 min has been developed. There are few questionnaires available for assessing musicality and musical activity with different aspects. The newly developed MusA in the German language focuses on the assessment of musical activity and is intended to be used in larger, population-based as well as clinical studies, to examine music activities and listening to music as independent factors in connection with prevention and therapy of chronic diseases. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Analysis of the necessity for inserting new surveillance capsule into the Kori Unit 1 RPV to monitor material fracture toughness

    International Nuclear Information System (INIS)

    Song, Taek Ho

    2007-01-01

    In association with monitoring of reactor pressure vessel (RPV) fracture toughness, surveillance capsule test specimens have been used to monitor the material property of nuclear reactor vessel. As far as Kori Unit 1 is concerned, 6 capsules were put into the vessel before commercial operation of the plant. Up to now, all the six capsules have been withdrawn to test and monitor the fracture toughness of RPV material. The last capsule has been withdrawn on June this year, and the Kori unit 1 has been shut downed since July 2007 and will be shut downed until December this year for about 6 months, preparing the life extension of the plant to operate the plant 10 more years. With the situation that all the surveillance capsules have been withdrawn, public ask the following question, 'To extend the life of Kori Unit 1 more than 10 years, is it necessary to insert new surveillance capsules into the Kori Unit 1 to monitor RPV material fracture toughness?' In connection with this issue, planning project have been carried out since spring this year. In this paper, it is described that inserting new surveillance capsule into the Kori Unit 1 RPV has some meaning in some public acceptance point of view and is not necessary in material engineering point of view

  7. First annual report RCRA post-closure monitoring and inspections for the U-3fi waste unit. Final report, July 1995--October 1996

    International Nuclear Information System (INIS)

    Emer, D.F.

    1997-01-01

    This annual Neutron Soil Moisture Monitoring report provides an analysis and summary for site inspections, meteorological information, and neutron soil moisture monitoring data obtained at the U-3fi RCRA Unit, located in Area 3 of the Nevada Site (NTS), Nye County, Nevada during the July 1995 to October 1996 period. Inspections of the U-3fi RCRA Unit are conducted to determine and document the physical condition of the covers, facilities, and any unusual conditions that could impact the proper operation of the waste unit closure. The objective of the neutron logging is to monitor the soil moisture conditions along the 420 ft ER3-3 borehole and detect changes that may be indicative of moisture movement in the regulated interval. This is the first annual report on the U-3fi closure and includes the first year baseline monitoring data as well as one quarter of compliance monitoring data

  8. An assessment of seismic monitoring in the United States; requirement for an Advanced National Seismic System

    Science.gov (United States)

    ,

    1999-01-01

    This report assesses the status, needs, and associated costs of seismic monitoring in the United States. It sets down the requirement for an effective, national seismic monitoring strategy and an advanced system linking national, regional, and urban monitoring networks. Modernized seismic monitoring can provide alerts of imminent strong earthquake shaking; rapid assessment of distribution and severity of earthquake shaking (for use in emergency response); warnings of a possible tsunami from an offshore earthquake; warnings of volcanic eruptions; information for correctly characterizing earthquake hazards and for improving building codes; and data on response of buildings and structures during earthquakes, for safe, cost-effective design, engineering, and construction practices in earthquake-prone regions.

  9. AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques.

    Science.gov (United States)

    Kamaleldin, Maha; Elsherbini, Nader A; Elshemey, Wael M

    2017-09-27

    The aim of this study is to evaluate the impact of anisotropic analytical algorithm (AAA) and 2 reporting systems (AXB-D m and AXB-D w ) of Acuros XB algorithm (AXB) on clinical plans of nasopharyngeal patients using intensity-modulated radiotherapy (IMRT) and RapidArc (RA) techniques. Six plans of different algorithm-technique combinations are performed for 10 patients to calculate dose-volume histogram (DVH) physical parameters for planning target volumes (PTVs) and organs at risk (OARs). The number of monitor units (MUs) and calculation time are also determined. Good coverage is reported for all algorithm-technique combination plans without exceeding the tolerance for OARs. Regardless of the algorithm, RA plans persistently reported higher D 2% values for PTV-70. All IMRT plans reported higher number of MUs (especially with AXB) than did RA plans. AAA-IMRT produced the minimum calculation time of all plans. Major differences between the investigated algorithm-technique combinations are reported only for the number of MUs and calculation time parameters. In terms of these 2 parameters, it is recommended to employ AXB in calculating RA plans and AAA in calculating IMRT plans to achieve minimum calculation times at reduced number of MUs. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  10. INFRARED SPECTROSCOPY OF SYMBIOTIC STARS. XI. ORBITS FOR SOUTHERN S-TYPE SYSTEMS: HEN 3-461, SY MUS, HEN 3-828, AND AR PAV

    International Nuclear Information System (INIS)

    Fekel, Francis C.; Hinkle, Kenneth H.; Joyce, Richard R.; Wood, Peter R.

    2017-01-01

    Employing new infrared radial velocities, we have computed spectroscopic orbits of the cool giants in four southern S-type symbiotic systems. The orbits for two of the systems, Hen 3-461 and Hen 3-828, have been determined for the first time, while orbits of the other two, SY Mus and AR Pav, have previously been determined. For the latter two systems, we compare our results with those in the literature. The low mass of the secondary of SY Mus suggests that it has gone through a common envelope phase. Hen 3-461 has an orbital period of 2271 days, one of the longest currently known for S-type symbiotic systems. That period is very different from the orbital period proposed previously from its photometric variations. The other three binaries have periods between 600 and 700 day, values that are typical for S-type symbiotic orbits. Basic properties of the M giant components and the distance to each system are determined.

  11. Development and implementation of a software for assessment of calculations in radiotherapy monitor units

    International Nuclear Information System (INIS)

    Mueller, Marcio Rogerio; Silva, Marco Antonio da; Rodrigues, Laura Natal

    2005-01-01

    Objective: To develop and implement a software based on the manual calculation algorithm for verification of the calculations in radiotherapy monitor units and to establish acceptance levels as a mechanism of quality assurance. Materials and methods: Data were obtained from Clinac 600C and 2100C Varian linear accelerators and the computerized treatment planning system used was CadPlan TM . Results: For the 6 MV beams the acceptance levels for deviations among the calculations of monitor units, divided by treatment area, were the following: breast (0.0%±1.7%), head and neck (1.5%±0.5%), hypophysis (-1.7%±0.5%), pelvis (2.1%±2.1%) and thorax (0.2%±1.3%). For the 15 MV beams the suggested level for pelvis in all the treatment techniques was (3.2%±1.3%). Conclusion: The present data are sufficient to justify the use of the software in the clinical practice as a tool for the quality assurance program. (author)

  12. Salamander chytrid fungus (Batrachochytrium salamandrivorans) in the United States—Developing research, monitoring, and management strategies

    Science.gov (United States)

    Grant, Evan H. Campbell; Muths, Erin L.; Katz, Rachel A.; Canessa, Stefano; Adams, Michael J.; Ballard, Jennifer R.; Berger, Lee; Briggs, Cheryl J.; Coleman, Jeremy; Gray, Matthew J.; Harris, M. Camille; Harris, Reid N.; Hossack, Blake R.; Huyvaert, Kathryn P.; Kolby, Jonathan E.; Lips, Karen R.; Lovich, Robert E.; McCallum, Hamish I.; Mendelson, Joseph R.; Nanjappa, Priya; Olson, Deanna H.; Powers, Jenny G.; Richgels, Katherine L. D.; Russell, Robin E.; Schmidt, Benedikt R.; Spitzen-van der Sluijs, Annemarieke; Watry, Mary Kay; Woodhams, Douglas C.; White, C. LeAnn

    2016-01-20

    The recently (2013) identified pathogenic chytrid fungus, Batrachochytrium salamandrivorans (Bsal), poses a severe threat to the distribution and abundance of salamanders within the United States and Europe. Development of a response strategy for the potential, and likely, invasion of Bsal into the United States is crucial to protect global salamander biodiversity. A formal working group, led by Amphibian Research and Monitoring Initiative (ARMI) scientists from the U.S. Geological Survey (USGS) Patuxent Wildlife Research Center, Fort Collins Science Center, and Forest and Rangeland Ecosystem Science Center, was held at the USGS Powell Center for Analysis and Synthesis in Fort Collins, Colorado, United States from June 23 to June 25, 2015, to identify crucial Bsal research and monitoring needs that could inform conservation and management strategies for salamanders in the United States. Key findings of the workshop included the following: (1) the introduction of Bsal into the United States is highly probable, if not inevitable, thus requiring development of immediate short-term and long-term intervention strategies to prevent Bsal establishment and biodiversity decline; (2) management actions targeted towards pathogen containment may be ineffective in reducing the long-term spread of Bsal throughout the United States; and (3) early detection of Bsal through surveillance at key amphibian import locations, among high-risk wild populations, and through analysis of archived samples is necessary for developing management responses. Top research priorities during the preinvasion stage included the following: (1) deployment of qualified diagnostic methods for Bsal and establishment of standardized laboratory practices, (2) assessment of susceptibility for amphibian hosts (including anurans), and (3) development and evaluation of short- and long-term pathogen intervention and management strategies. Several outcomes were achieved during the workshop, including development

  13. Portable air quality sensor unit for participatory monitoring: an end-to-end VESNA-AQ based prototype

    Science.gov (United States)

    Vucnik, Matevz; Robinson, Johanna; Smolnikar, Miha; Kocman, David; Horvat, Milena; Mohorcic, Mihael

    2015-04-01

    Key words: portable air quality sensor, CITI-SENSE, participatory monitoring, VESNA-AQ The emergence of low-cost easy to use portable air quality sensors units is opening new possibilities for individuals to assess their exposure to air pollutants at specific place and time, and share this information through the Internet connection. Such portable sensors units are being used in an ongoing citizen science project called CITI-SENSE, which enables citizens to measure and share the data. The project aims through creating citizens observatories' to empower citizens to contribute to and participate in environmental governance, enabling them to support and influence community and societal priorities as well as associated decision making. An air quality measurement system based on VESNA sensor platform was primarily designed within the project for the use as portable sensor unit in selected pilot cities (Belgrade, Ljubljana and Vienna) for monitoring outdoor exposure to pollutants. However, functionally the same unit with different set of sensors could be used for example as an indoor platform. The version designed for the pilot studies was equipped with the following sensors: NO2, O3, CO, temperature, relative humidity, pressure and accelerometer. The personal sensor unit is battery powered and housed in a plastic box. The VESNA-based air quality (AQ) monitoring system comprises the VESNA-AQ portable sensor unit, a smartphone app and the remote server. Personal sensor unit supports wireless connection to an Android smartphone via built-in Wi-Fi. The smartphone in turn serves also as the communication gateway towards the remote server using any of available data connections. Besides the gateway functionality the role of smartphone is to enrich data coming from the personal sensor unit with the GPS location, timestamps and user defined context. This, together with an accelerometer, enables the user to better estimate ones exposure in relation to physical activities, time

  14. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  15. Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)

    International Nuclear Information System (INIS)

    Guan, Huaiqun; Zhu, Yunping

    1998-01-01

    Although electronic portal imaging devices (EPIDs) are efficient tools for radiation therapy verification, they only provide images of overlapped anatomic structures. We investigated using a fluorescent screen/CCD-based EPID, coupled with a novel multi-level scheme algebraic reconstruction technique (MLS-ART), for a feasibility study of portal computed tomography (CT) reconstructions. The CT images might be useful for radiation treatment planning and verification. We used an EPID, set it to work at the linear dynamic range and collimated 6 MV photons from a linear accelerator to a slit beam of 1 cm wide and 25 cm long. We performed scans under a total of ∼200 monitor units (MUs) for several phantoms in which we varied the number of projections and MUs per projection. The reconstructed images demonstrated that using the new MLS-ART technique megavoltage portal CT with a total of 200 MUs can achieve a contrast detectibility of ∼2.5% (object size 5mmx5mm) and a spatial resolution of 2.5 mm. (author)

  16. The Effect of Curry Leaves (Murayya Koenigii L. on Blood Glucose Levels In Alloxan Diabetic Mice (Mus Musculus

    Directory of Open Access Journals (Sweden)

    Fauziah Fauziah

    2014-07-01

    Full Text Available This study was conducted to determine the effect of ethanol extract of curry leaves (Murraya koenigii L. on blood glucose levels in alloxan diabetic mice (Mus musculus. The diabetic conditions were made by giving alloxan 75 mg/kg body weight (BW and the hypoglycemic effects of extract of curry leaves given with various doses.   This study used 24 male mice strain Balb/c in four groups of treatment with six replications, namely the negative control group, the ethanol extract of curry leaf tree 50% mL/10g body weight group, 70% mL/10g body weight group and 90% mL/10g body weight group. The treatment was given orally by using a gastric sonde for 14 days. Blood samples were taken through the sinus caudalis using a scissors. Blood glucose level was measured at 1st , the 8th and the 24th of treatment using blood glucose test strips and Nesco® Multicheck apparatus. Blood glucose data were analyzed by one way ANOVA (Analysis of Variants and followed by Tuckey test at significance level of 5%. The result showed that treatment of ethanol extract of curry leaves (Murraya koenigii at various doses significantly affected the decrease on blood glucose levels of mice (Mus musculus alloxan diabetic.

  17. PRDM9 drives evolutionary erosion of hotspots in Mus musculus through haplotype-specific initiation of meiotic recombination.

    Science.gov (United States)

    Baker, Christopher L; Kajita, Shimpei; Walker, Michael; Saxl, Ruth L; Raghupathy, Narayanan; Choi, Kwangbom; Petkov, Petko M; Paigen, Kenneth

    2015-01-01

    Meiotic recombination generates new genetic variation and assures the proper segregation of chromosomes in gametes. PRDM9, a zinc finger protein with histone methyltransferase activity, initiates meiotic recombination by binding DNA at recombination hotspots and directing the position of DNA double-strand breaks (DSB). The DSB repair mechanism suggests that hotspots should eventually self-destruct, yet genome-wide recombination levels remain constant, a conundrum known as the hotspot paradox. To test if PRDM9 drives this evolutionary erosion, we measured activity of the Prdm9Cst allele in two Mus musculus subspecies, M.m. castaneus, in which Prdm9Cst arose, and M.m. domesticus, into which Prdm9Cst was introduced experimentally. Comparing these two strains, we find that haplotype differences at hotspots lead to qualitative and quantitative changes in PRDM9 binding and activity. Using Mus spretus as an outlier, we found most variants affecting PRDM9Cst binding arose and were fixed in M.m. castaneus, suppressing hotspot activity. Furthermore, M.m. castaneus×M.m. domesticus F1 hybrids exhibit novel hotspots, with large haplotype biases in both PRDM9 binding and chromatin modification. These novel hotspots represent sites of historic evolutionary erosion that become activated in hybrids due to crosstalk between one parent's Prdm9 allele and the opposite parent's chromosome. Together these data support a model where haplotype-specific PRDM9 binding directs biased gene conversion at hotspots, ultimately leading to hotspot erosion.

  18. Adjustment of the Kompleks Titan-2 monitoring computerized system at the Rovno NPP third unit

    International Nuclear Information System (INIS)

    Zigaev, B.P.

    1987-01-01

    Information signal origin and processing processes in the monitoring computerized system 'Komplex Titan-2' at the Rovno NPP third unit are considered. The system exercises control over the following production equipment parameters: the state of keys of control of lock fittings, mechanisms, regulators, reserve mechanism automatic shut-down circuit; the state of lock fittings, mechanisms, regulators, reserve mechanism automated switching on; parameter deviation from permissible values; interlock operation; protection system state; the state of autonomous units and devices

  19. Post-Closure Inspection and Monitoring Report for Corrective Action Unit 110: Area 3 WMD U-3ax/bl Crater, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Bechtel Nevada

    2006-08-01

    This Post-Closure Inspection and Monitoring Report provides the results and inspections and monitoring for Corrective Action Unit 110: Area 3 Waste Management Division U-3ax/bl Crater, Nevada Test Site, Nevada. This report includes an analysis and summary of the site inpsections, repairs and maintenance, meteorological information, and soil moisture monitoring data obtained at Corrective Action Unit 110, for the annual period July 2005 thrugh June 2006.

  20. Development of a reference Phasor Measurement Unit (PMU) for the monitoring and control of grid stability and quality

    Science.gov (United States)

    Ndilimabaka, Hervé; Blanc, Isabelle

    2014-08-01

    This paper discusses the details of the development of a Phasor Measurement Unit regarding the requirements of the IEEE C37.118-2005 synchrophasor standard relative to steady-state conditions on grid monitoring and control. This phasor measurement unit is intended to be used for field tests sooner.

  1. Combinatorial regulation of meiotic holliday junction resolution in C. elegans by HIM-6 (BLM) helicase, SLX-4, and the SLX-1, MUS-81 and XPF-1 nucleases.

    Science.gov (United States)

    Agostinho, Ana; Meier, Bettina; Sonneville, Remi; Jagut, Marlène; Woglar, Alexander; Blow, Julian; Jantsch, Verena; Gartner, Anton

    2013-01-01

    Holliday junctions (HJs) are cruciform DNA structures that are created during recombination events. It is a matter of considerable importance to determine the resolvase(s) that promote resolution of these structures. We previously reported that C. elegans GEN-1 is a symmetrically cleaving HJ resolving enzyme required for recombinational repair, but we could not find an overt role in meiotic recombination. Here we identify C. elegans proteins involved in resolving meiotic HJs. We found no evidence for a redundant meiotic function of GEN-1. In contrast, we discovered two redundant HJ resolution pathways likely coordinated by the SLX-4 scaffold protein and also involving the HIM-6/BLM helicase. SLX-4 associates with the SLX-1, MUS-81 and XPF-1 nucleases and has been implicated in meiotic recombination in C. elegans. We found that C. elegans [mus-81; xpf-1], [slx-1; xpf-1], [mus-81; him-6] and [slx-1; him-6] double mutants showed a similar reduction in survival rates as slx-4. Analysis of meiotic diakinesis chromosomes revealed a distinct phenotype in these double mutants. Instead of wild-type bivalent chromosomes, pairs of "univalents" linked by chromatin bridges occur. These linkages depend on the conserved meiosis-specific transesterase SPO-11 and can be restored by ionizing radiation, suggesting that they represent unresolved meiotic HJs. This suggests the existence of two major resolvase activities, one provided by XPF-1 and HIM-6, the other by SLX-1 and MUS-81. In all double mutants crossover (CO) recombination is reduced but not abolished, indicative of further redundancy in meiotic HJ resolution. Real time imaging revealed extensive chromatin bridges during the first meiotic division that appear to be eventually resolved in meiosis II, suggesting back-up resolution activities acting at or after anaphase I. We also show that in HJ resolution mutants, the restructuring of chromosome arms distal and proximal to the CO still occurs, suggesting that CO initiation

  2. 40 CFR Table 31 to Subpart Uuu of... - Continuous Monitoring Systems for HAP Emissions From Sulfur Recovery Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Monitoring Systems for HAP Emissions From Sulfur Recovery Units 31 Table 31 to Subpart UUU of Part 63 Protection of Environment..., Subpt. UUU, Table 31 Table 31 to Subpart UUU of Part 63—Continuous Monitoring Systems for HAP Emissions...

  3. Model of chromosome associations in Mus domesticus spermatocytes

    Directory of Open Access Journals (Sweden)

    Soledad Berríos

    2010-01-01

    Full Text Available Understanding the spatial organization of the chromosomes in meiotic nuclei is crucial to our knowledge of the genome's functional regulation, stability and evolution. This study examined the nuclear architecture of Mus domesticus 2n=40 pachytene spermatocytes, analyzing the associations among autosomal bivalents via their Centromere Telomere Complexes (CTC. The study developed a nuclear model in which each CTC was represented as a 3D computer object. The probability of a given combination of associations among CTC was estimated by simulating a random distribution of 19 indistinguishable CTC over n indistinguishable "cells" on the nuclear envelope. The estimated association frequencies resulting from this numerical approach were similar to those obtained by quantifying actual associations in pachytene spermatocyte spreads. The nuclear localization and associations of CTC through the meiotic prophase in well-preserved nuclei were also analyzed. We concluded that throughout the meiotic prophase: 1 the CTC of autosomal bivalents are not randomly distributed in the nuclear space; 2 the CTC associate amongst themselves, probably at random, over a small surface of the nuclear envelope, at the beginning of the meiotic prophase; 3 the initial aggregation of centromere regions occurring in lepto-zygotene likely resolves into several smaller aggregates according to patterns of preferential partitioning; 4 these smaller aggregates spread over the inner face of the nuclear envelope, remaining stable until advanced stages of the meiotic prophase or even until the first meiotic division.

  4. Influence of the contractile properties of muscle on motor unit firing rates during a moderate-intensity contraction in vivo.

    Science.gov (United States)

    Trevino, Michael A; Herda, Trent J; Fry, Andrew C; Gallagher, Philip M; Vardiman, John P; Mosier, Eric M; Miller, Jonathan D

    2016-08-01

    It is suggested that firing rate characteristics of motor units (MUs) are influenced by the physical properties of the muscle. However, no study has correlated MU firing rates at recruitment, targeted force, or derecruitment with the contractile properties of the muscle in vivo. Twelve participants (age = 20.67 ± 2.35 yr) performed a 40% isometric maximal voluntary contraction of the leg extensors that included linearly increasing, steady force, and decreasing segments. Muscle biopsies were collected with myosin heavy chain (MHC) content quantified, and surface electromyography (EMG) was recorded from the vastus lateralis. The EMG signal was decomposed into the firing events of single MUs. Slopes and y-intercepts were calculated for 1) firing rates at recruitment vs. recruitment threshold, 2) mean firing rates at steady force vs. recruitment threshold, and 3) firing rates at derecruitment vs. derecruitment threshold relationships for each subject. Correlations among type I %MHC isoform content and the slopes and y-intercepts from the three relationships were examined. Type I %MHC isoform content was correlated with MU firing rates at recruitment (y-intercepts: r = -0.577; slopes: r = 0.741) and targeted force (slopes: r = 0.853) vs. recruitment threshold and MU firing rates at derecruitment (y-intercept: r = -0.597; slopes: r = 0.701) vs. derecruitment threshold relationships. However, the majority of the individual MU firing rates vs. recruitment and derecruitment relationships were not significant (P > 0.05) and, thus, revealed no systematic pattern. In contrast, MU firing rates during the steady force demonstrated a systematic pattern with higher firing rates for the lower- than higher-threshold MUs and were correlated with the physical properties of MUs in vivo. Copyright © 2016 the American Physiological Society.

  5. Development of a reference Phasor Measurement Unit (PMU for the monitoring and control of grid stability and quality

    Directory of Open Access Journals (Sweden)

    Ndilimabaka Hervé

    2014-01-01

    Full Text Available This paper discusses the details of the development of a Phasor Measurement Unit regarding the requirements of the IEEE C37.118-2005 synchrophasor standard relative to steady-state conditions on grid monitoring and control. This phasor measurement unit is intended to be used for field tests sooner.

  6. The screening of parasites and viral pathogens of small mammals from a farm in southern Finland, and genetic identification of the Finnish house mouse, Mus musculus

    Czech Academy of Sciences Publication Activity Database

    Laakkonen, J.; Kallio-Kokko, M.; Vapalahti, O.; Vaheri, A.; Vyskočilová, M.; Munclinger, P.; Macholán, Miloš; Henttonen, H.

    2007-01-01

    Roč. 44, - (2007), s. 202-208 ISSN 0003-455X EU Projects: European Commission(XE) 10284 - EDEN Institutional research plan: CEZ:AV0Z50450515 Keywords : Mus musculus Subject RIV: EG - Zoology Impact factor: 1.537, year: 2007

  7. A General Mathematical Algorithm for Predicting the Course of Unfused Tetanic Contractions of Motor Units in Rat Muscle.

    Directory of Open Access Journals (Sweden)

    Rositsa Raikova

    Full Text Available An unfused tetanus of a motor unit (MU evoked by a train of pulses at variable interpulse intervals is the sum of non-equal twitch-like responses to these stimuli. A tool for a precise prediction of these successive contractions for MUs of different physiological types with different contractile properties is crucial for modeling the whole muscle behavior during various types of activity. The aim of this paper is to develop such a general mathematical algorithm for the MUs of the medial gastrocnemius muscle of rats. For this purpose, tetanic curves recorded for 30 MUs (10 slow, 10 fast fatigue-resistant and 10 fast fatigable were mathematically decomposed into twitch-like contractions. Each contraction was modeled by the previously proposed 6-parameter analytical function, and the analysis of these six parameters allowed us to develop a prediction algorithm based on the following input data: parameters of the initial twitch, the maximum force of a MU and the series of pulses. Linear relationship was found between the normalized amplitudes of the successive contractions and the remainder between the actual force levels at which the contraction started and the maximum tetanic force. The normalization was made according to the amplitude of the first decomposed twitch. However, the respective approximation lines had different specific angles with respect to the ordinate. These angles had different and non-overlapping ranges for slow and fast MUs. A sensitivity analysis concerning this slope was performed and the dependence between the angles and the maximal fused tetanic force normalized to the amplitude of the first contraction was approximated by a power function. The normalized MU contraction and half-relaxation times were approximated by linear functions depending on the normalized actual force levels at which each contraction starts. The normalization was made according to the contraction time of the first contraction. The actual force levels

  8. Parâmetros morfofisiológicos testiculares de camundongos (Mus musculus suplementados com geleia real Morphophysiological parameters of mice (Mus musculus testicles supplemented with royal jelly

    Directory of Open Access Journals (Sweden)

    A.C.T. Morais

    2009-02-01

    Full Text Available Avaliaram-se os efeitos da geleia real sobre os parâmetros morfofisiológicos testiculares de camundongos (Mus musculus. Utilizaram-se 57 machos Swiss, com quatro meses de idade, distribuídos aleatoriamente em seis tratamentos: T1: solução fisiológica, via intraperitoneal; T2: 0,1mg de geleia real, via intraperitoneal; T3: 0,2mg de geleia real, via intraperitoneal; T4: água destilada, via oral; T5: 0,1mg de geleia real, via oral; e T6: 0,2mg de geleia real, via oral. Após 45 dias de suplementação com geleia real, os animais sacrificados e pesados tiveram seus testículos coletados, incluídos em parafina e corados com hematoxilina/eosina. Não houve diferença entre os tratamentos quanto aos: pesos corporal e testicular, índice gonadossomático, diâmetro tubular, altura do epitélio, comprimento total dos túbulos seminíferos, comprimento tubular por grama de testículo, índices tubulossomático e leydigossomático e valores de proporção volumétrica referentes à túnica própria, epitélio seminífero, vaso sanguíneo e vaso linfático. Foi encontrada diferença entre T1 e T3 em relação aos túbulos seminíferos e ao espaço intertubular.The effects of royal jelly on the morphophysiological parameters of mice (Mus musculus testicles were studied. Fifty-eight male Swiss mice were evaluated. They were four-month old and were randomly distributed in six treatments: T1: physiological solution, intraperitonial route; T2: 0.1mg of royal jelly, intraperitonial route; T3: 0.2mg of royal jelly, intraperitonial route; T4: distilled water, orally; T5: 0.1mg of royal jelly, orally; and T6: 0.2mg of royal jelly, orally. After 45 days of supplementation with royal jelly, the animals were weighted, slaughtered, and the testicles collected, included in paraffin, and stained with haematoxylin-eosin. No differences among treatments were observed for: body and testicular weights, gonadossomatic index, tubular diameter, epithelial height, total

  9. Applications of the monitor of loose parts in the cycle 6 of the Laguna Verde Unit 2 power plant

    International Nuclear Information System (INIS)

    Calleros, G.; Mendez, A.; Gomez, R.A.; Castillo, R.; Bravo, J.M.

    2004-01-01

    The monitor of loose parts (Loose Parts Monitoring System) installed in the Unit 2 of the Laguna Verde Central is a tool to detect strange objects or parts loose in the system of refrigeration of the reactor that could be impacted in the walls of the recirculation knots or in the internal of the reactor. In this work two applications are shown carried out with the Monitor of Loose Parts, determining the characteristics of the stable nominal conditions, those which when changing, they are used to diagnose during the Cycle 6 of the Unit 2, failures in the components of the the recirculation circuits or to identify mechanical vibrations of the recirculation knots induced by a flow of recirculation bistable associated to operative conditions of the reactor. (Author)

  10. Successful global assessments and monitoring: The roles of the international community and the United States

    International Nuclear Information System (INIS)

    Lund, H.G.

    1991-01-01

    Successful global assessments and monitoring of natural resources requires teamwork between participating nations and the international communities charged with the responsibility for collecting and disseminating information. In an attempt to identify emerging information needs and to promote coordination, the International Union of Forestry Research Organizations (IUFRO) and other national and international groups held a major conference and workshop in Venice, Italy, on global monitoring last September. The results of the meeting and subsequent events in Montreal indicated a need for more aggressive leadership at the international level and more cooperation at the national level. This paper reports on the outcome of the Venice conference and list some things that the international community and the United States must do to make global assessments and monitoring a reality

  11. Annual Radiological Environmental Monitoring Program Report for the Three Mile Island, Unit 2, Independent Spent Fuel Storage Installation

    International Nuclear Information System (INIS)

    Hall, Gregory Graham

    2002-01-01

    This report presents the results of the 2001 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Three Mile Island, Unit 2, Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the two predominant radiation exposure pathways, potential airborne radioactivity releases and direct radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.

  12. Patterns of motor recruitment can be determined using surface EMG.

    Science.gov (United States)

    Wakeling, James M

    2009-04-01

    Previous studies have reported how different populations of motor units (MUs) can be recruited during dynamic and locomotor tasks. It was hypothesised that the higher-threshold units would contribute higher-frequency components to the sEMG spectra due to their faster conduction velocities, and thus recruitment patterns that increase the proportion of high-threshold units active would lead to higher-frequency elements in the sEMG spectra. This idea was tested by using a model of varying recruitment coupled to a three-layer volume conductor model to generate a series of sEMG signals. The recruitment varied from (A) orderly recruitment where the lowest-threshold MUs were initially activated and higher-threshold MUs were sequentially recruited as the contraction progressed, (B) a recurrent inhibition model that started with orderly recruitment, but as the higher-threshold units were activated they inhibited the lower-threshold MUs (C) nine models with intermediate properties that were graded between these two extremes. The sEMG was processed using wavelet analysis and the spectral properties quantified by their mean frequency, and an angle theta that was determined from the principal components of the spectra. Recruitment strategies that resulted in a greater proportion of faster MUs being active had a significantly lower theta and higher mean frequency.

  13. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  14. SU-E-T-110: An Investigation On Monitor Unit Threshold and Effects On IMPT Delivery in Proton Pencil Beam Planning System

    International Nuclear Information System (INIS)

    Syh, J; Ding, X; Syh, J; Patel, B; Rosen, L; Wu, H

    2015-01-01

    Purpose: An approved proton pencil beam scanning (PBS) treatment plan might not be able to deliver because of existed extremely low monitor unit per beam spot. A dual hybrid plan with higher efficiency of higher spot monitor unit and the efficacy of less number of energy layers were searched and optimized. The range of monitor unit threshold setting was investigated and the plan quality was evaluated by target dose conformity. Methods: Certain limitations and requirements need to be checks and tested before a nominal proton PBS treatment plan can be delivered. The plan needs to be met the machine characterization, specification in record and verification to deliver the beams. Minimal threshold of monitor unit, e.g. 0.02, per spot was set to filter the low counts and plan was re-computed. Further MU threshold increment was tested in sequence without sacrificing the plan quality. The number of energy layer was also alternated due to elimination of low count layer(s). Results: Minimal MU/spot threshold, spot spacing in each energy layer and total number of energy layer and the MU weighting of beam spots of each beam were evaluated. Plan optimization between increases of the spot MU (efficiency) and less energy layers of delivery (efficacy) was adjusted. 5% weighting limit of total monitor unit per beam was feasible. Scarce spreading of beam spots was not discouraging as long as target dose conformity within 3% criteria. Conclusion: Each spot size is equivalent to the relative dose in the beam delivery system. The energy layer is associated with the depth of the targeting tumor. Our work is crucial to maintain the best possible quality plan. To keep integrity of all intrinsic elements such as spot size, spot number, layer number and the carried weighting of spots in each layer is important in this study

  15. Novel arenavirus sequences in Hylomyscus sp. and Mus (Nannomys setulosus from Côte d'Ivoire: implications for evolution of arenaviruses in Africa.

    Directory of Open Access Journals (Sweden)

    David Coulibaly-N'Golo

    Full Text Available This study aimed to identify new arenaviruses and gather insights in the evolution of arenaviruses in Africa. During 2003 through 2005, 1,228 small mammals representing 14 different genera were trapped in 9 villages in south, east, and middle west of Côte d'Ivoire. Specimens were screened by pan-Old World arenavirus RT-PCRs targeting S and L RNA segments as well as immunofluorescence assay. Sequences of two novel tentative species of the family Arenaviridae, Menekre and Gbagroube virus, were detected in Hylomyscus sp. and Mus (Nannomys setulosus, respectively. Arenavirus infection of Mus (Nannomys setulosus was also demonstrated by serological testing. Lassa virus was not found, although 60% of the captured animals were Mastomys natalensis. Complete S RNA and partial L RNA sequences of the novel viruses were recovered from the rodent specimens and subjected to phylogenetic analysis. Gbagroube virus is a closely related sister taxon of Lassa virus, while Menekre virus clusters with the Ippy/Mobala/Mopeia virus complex. Reconstruction of possible virus-host co-phylogeny scenarios suggests that, within the African continent, signatures of co-evolution might have been obliterated by multiple host-switching events.

  16. Reflexões sobre a arte "primitiva": o caso do Musée Branly

    Directory of Open Access Journals (Sweden)

    Ilana Goldstein

    2008-06-01

    Full Text Available Na época das descobertas ultramarinas, os europeus acumulavam fragmentos das novas realidades que encontravam em suas viagens, nos chamados gabinetes de curiosidades. Os colecionadores se especializaram e, a partir do século XVIII, surgiram os primeiros museus científicos. No final do século XIX, as exposições universais expunham a "barbárie" dos povos colonizados. Já as vanguardas do século XX redescobriram a arte "primitiva" enquanto fonte de renovação. Este artigo recupera tais formas de apreensão da cultura material de sociedades tradicionais ao longo do tempo, para chegar à inauguração do Musée Branly, em 2006. A partir desse museu, podem-se repensar algumas questões fundamentais acerca da arte "primitiva", como a dicotomia entre tratar os artefatos como testemunhos etnográficos ou como criações estéticas; as relações de poder envolvidas na aquisição dos objetos; o problema da autenticidade, numa era em que se multiplicam os souvenirs étnicos "neotradicionais".In the epoch of overseas discoveries, Europeans accumulated fragments of the realities they found in cabinets of curiosities. The private collectors specialized in different branches of "natural history" and this led to the emergence of scientific museums in the 18th century. At the end of the 19th century, universal exhibitions displayed "primitive" artifacts side by side with Western technologies, suggesting the "barbarism" of colonized peoples. But, at the beginning of the 20th century, the avant-gardes rediscovered the art nègre, using it as a source of artistic renovation. This article begins by describing these various forms of dealing with the cultural expressions of others, in order to understand the meaning of the recently opened Musée Branly. The French museum, devoted to non-occidental societies, provides an opportunity to reconsider some fundamental issues. Should we exhibit these artifacts as ethnographic testimonies or works of art? Can we

  17. Application of an automated patrol-type monitoring system in the reinforced concrete containment vessel at Kashiwazaki-Kariwa Nuclear Power Plant Units 6 and 7

    International Nuclear Information System (INIS)

    Kimoto, T.; Senoh, M.; Hirakawa, H.; Tanaka, K.; Takahashi, M.

    1996-01-01

    An automated patrol-type monitoring system was applied to the first Advanced Boiling Water Reactor (ABWR) plants in the world, Kashiwazaki-Kariwa Nuclear Power Plant Units 6 and 7. The system consists of two robots traveling along monorail and several ITV systems. This monitoring system is used to watch the operating incident of key components of ABWR, such as water leakage from packing in Fine Motion Control Rod Drive (FM-CRD), Reactor Internal Pump (RIP) etc. which are located in the reinforced concrete containment and usually could not be accessible under operation. The traveling robots are equipped with the three kinds of sensors, an infrared camera, a color TV camera and a microphone, and have a capability to inspect the pre-determined inspection points guided by the monorail. This monitoring system is automatically turned on to start inspection at a scheduled time. For Units 6 and 7, this monitoring system, two robots and several ITV systems, can be controlled from one common control desk and one handy-type remote control panel. Since this monitoring system was installed at Kashiwazaki-Kariwa Nuclear Power Plant Units 6 and 7, this system has been operating successfully. (The installation and testing of the system for Unit 6 was finished completely and the testing the system for Unit 7 has been carrying out.) (author)

  18. A program for monitor unit calculation for high energy photon beams in isocentric condition based on measured data

    International Nuclear Information System (INIS)

    Gesheva-Atanasova, N.

    2008-01-01

    The aim of this study is: 1) to propose a procedure and a program for monitor unit calculation for radiation therapy with high energy photon beams, based on data measured by author; 2) to compare this data with published one and 3) to evaluate the precision of the monitor unit calculation program. From this study it could be concluded that, we reproduced with a good agreement the published data, except the TPR values for dept up to 5 cm. The measured relative weight of upper and lower jaws - parameter A was dramatically different from the published data, but perfectly described the collimator exchange effect for our treatment machine. No difference was found between the head scatter ratios, measured in a mini phantom and those measured with a proper brass buildup cap. Our monitor unit calculation program was found to be reliable and it can be applied for check up of the patient's plans for irradiation with high energy photon beams and for some fast calculations. Because of the identity in the construction, design and characteristics of the Siemens accelerators, and the agreement with the published data for the same beam qualities, we hope that most of our experimental data and this program can be used after verification in other hospitals

  19. Effect of Pasak Bumi (Eurycoma longifolia Jack) Root In Precopulation Stage to the Fertility of Female Mouse (Mus musculus L.)

    OpenAIRE

    Marlinza, Rosa

    2012-01-01

    Pasak Bumi (Eurycoma longifolia Jack) have potency to be used to increase bodyendurance, to cure malaria drug, and to act as afrodisiak. However, the effect of pasak bumi onwomen fertility, especially at pre-copulation stage was not widely known. This research seeks toreveal the effect pasak bumi extract treated at pre-copulation phase on fertility. This experimentemploy mice (Mus Musculus L.) and was undertaken at Biology and Cemistry laboratories PMIPA, andVeterinary laboratory of Jambi Uni...

  20. The Detector Control Unit An ASIC for the monitoring of the CMS silicon tracker

    CERN Document Server

    Magazzù, G; Moreira, P

    2004-01-01

    The Detector Control Unit (DCU) is an ASIC developed as the central building block of a monitoring system for the CMS Tracker. Leakage currents in the Silicon detectors, power supply voltages of the readout electronics and local temperatures will be monitored in order to guarantee safe operating conditions during the 10-years lifetime in the LHC environment. All these measurements can be performed by an A/D converter preceded by an analog multiplexer and properly interfaced to the central control system. The requirements in terms of radiation tolerance, low-power dissipation and integration with the rest of the system led to the design of a custom integrated circuit. Its structure and characteristics are described in this paper. (6 refs).

  1. Enhancement of hand hygiene compliance among health care workers from a hemodialysis unit using video-monitoring feedback.

    Science.gov (United States)

    Sánchez-Carrillo, Laura Arelí; Rodríguez-López, Juan Manuel; Galarza-Delgado, Dionisio Ángel; Baena-Trejo, Laura; Padilla-Orozco, Magaly; Mendoza-Flores, Lidia; Camacho-Ortiz, Adrián

    2016-08-01

    The importance of hand hygiene in the prevention of health care-associated infection is well known. Experience with hand hygiene compliance (HHC) evaluation in hemodialysis units is scarce. This study was a 3-phase, prospective longitudinal intervention study during a 5-month period in a 13-bed hemodialysis unit at a university hospital in Northern Mexico. The unit performs an average of 1,150 hemodialysis procedures per month. Compliance was evaluated by a direct observer and a video assisted observer. Feedback was given to health care workers in the form of educational sessions and confidential reports and video analysis of compliance and noncompliance. A total of 5,402 hand hygiene opportunities were registered; 5,201 during 7,820 minutes of video footage and 201 by direct observation during 1,180 minutes. Lower compliance during the baseline evaluation was observed by video monitoring compared with direct observation (P hand hygiene compliance. Video-assisted monitoring of hand hygiene is an excellent method for the evaluation of HHC in a hemodialysis unit; enhanced HHC can be achieved through a feedback program to the hemodialysis staff that includes video examples and confidential reports. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. PENGARUH TRITERPEN TOTAL PEGAGAN (Centella asiatica (L Urban TERHADAP FUNGSI KOGNITIF BELAJAR DAN MENGINGAT PADA MENCIT JANTAN ALBINO (Mus musculus YANG DIHAMBAT DENGAN SKOPOLAMIN

    Directory of Open Access Journals (Sweden)

    Herlina

    2010-11-01

    Full Text Available Pegagan (Centella asiatica (L Urban has been described to posses CNS effects such as improving cognitive function, learning and memory. The aim of the research was to evaluate the effects of total triterpen’s pegagan extract on cognitive functions as the learning and memory performance in male albino mice (Mus musculus inhibited by scopolamine. The research design was Complete Randomized Design (RAL – factorial on thirty six mice divided into 4 groups. One control group received only aquabidest (negative control. Three treatment groups received total triterpen 16 mg/kg BW, 32 mg/kg BW orally and piracetam 500 mg/kg BW by intra peritoneally (positive control for 21 days. Data indicating learning and memory process of all subjects were obtained from one-trial passive avoidance test. Data were analyzed by two way ANOVA and BNT (p0,05. In conclusion, total triterpen from pegagan (Centella asiatica (L Urban improved learning ability and memory of male albino mice (Mus musculus even though, it was inhibited by scopolamine.

  3. iTRAQ analysis of hepatic proteins in free-living Mus spretus mice to assess the contamination status of areas surrounding Doñana National Park (SW Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Abril, Nieves; Chicano-Gálvez, Eduardo; Michán, Carmen; Pueyo, Carmen; López-Barea, Juan, E-mail: bb1lobaj@uco.es

    2015-08-01

    This work aims to develop and integrate new -omics tools that would be applicable to different ecosystem types for a technological updating of environmental evaluations. We used a 2nd-generation (iTRAQ-8plex) proteomic approach to identify/quantify proteins differentially expressed in the liver of free-living Mus spretus mice from Doñana National Park or its proximities. Mass spectrometry was performed in an LTQ Orbitrap system for iTRAQ reporter ion quantitation and protein identification using a Mus musculus database as reference. A prior IEF step improved the separation of the complex peptide mixture. Over 2000 identified proteins were altered, of which 118 changed by ≥ 2.5-fold in mice from at least two problem sites. Part of the results obtained with the iTRAQ analysis was confirmed by Western blot. Over 75% of the 118 proteins were upregulated in animals captured at polluted sites and only 16 proteins were downregulated. Upregulated proteins were involved in stress response; cell proliferation and apoptosis; signal transduction; metastasis or tumour suppression; xenobiotic export or vesicular trafficking; and metabolism. The downregulated proteins, all potentially harmful, were classified as oncoproteins and proteins favouring genome instability. The iTRAQ results presented here demonstrated that the survival of hepatic cells is compromised in animals living at polluted sites, which showed deep alterations in metabolism and the signalling pathways. The identified proteins may be useful as biomarkers of environmental pollution and provide insight about the metabolic pathways and/or physiological processes affected by pollutants in DNP and its surrounding areas. - Highlights: • iTRAQ quantitation was used for the first time to monitor a wildlife reserve • Over 2,000 proteins with altered expression were identified in problem Doñana sites • Of them, 118 changed over 2.5-fold in, at least, two problem sites • Upregulation of protective proteins

  4. Regional monitoring programs in the United States: Synthesis of four case studies from Pacific, Atlantic, and Gulf Coasts

    Science.gov (United States)

    Tango, Peter J.; Schiff, K.; Trowbridge, P.R.; Sherwood, E.T.; Batiuk, R.A.

    2016-01-01

    Water quality monitoring is a cornerstone of environmental protection and ambient monitoring provides managers with the critical data they need to take informed action. Unlike site-specific monitoring that is at the heart of regulatory permit compliance, regional monitoring can provide an integrated, holistic view of the environment, allowing managers to obtain a more complete picture of natural variability and cumulative impacts, and more effectively prioritize management actions. By reviewing four long-standing regional monitoring programs that cover portions of all three coasts in the United States – Chesapeake Bay, Tampa Bay, Southern California Bight, and San Francisco Bay – important insights can be gleaned about the benefits that regional monitoring provides to managers. These insights include the underlying reasons that make regional monitoring programs successful, the challenges to maintain relevance and viability in the face of ever-changing technology, competing demands and shifting management priorities. The lessons learned can help other managers achieve similar successes as they seek to establish and reinvigorate their own monitoring programs.

  5. 40 CFR Table 17 to Subpart Uuu of... - Continuous Monitoring Systems for Organic HAP Emissions From Catalytic Reforming Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Monitoring Systems for Organic HAP Emissions From Catalytic Reforming Units 17 Table 17 to Subpart UUU of Part 63 Protection of... Organic HAP Emissions From Catalytic Reforming Units As stated in § 63.1566(b)(1), you shall meet each...

  6. 40 CFR Table 10 to Subpart Uuu of... - Continuous Monitoring Systems for Organic HAP Emissions From Catalytic Cracking Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Monitoring Systems for Organic HAP Emissions From Catalytic Cracking Units 10 Table 10 to Subpart UUU of Part 63 Protection of... Organic HAP Emissions From Catalytic Cracking Units As stated in § 63.1565(b)(1), you shall meet each...

  7. Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario

    OpenAIRE

    Mishra, Bibekananda; Selvam, T. Palani; Sharma, P. K. Dash

    2017-01-01

    Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP) Report No. 151 and the other based on the monitor units (MUs) delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP a...

  8. Motor unit firing rate patterns during voluntary muscle force generation: a simulation study

    Science.gov (United States)

    Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.

    2014-04-01

    Objective. Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse ‘onion skin’ profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the ‘onion skin’ profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Approach. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. Main results. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse ‘onion skin’ pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the ‘onion skin’ pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the ‘onion skin’ paradigm than with the reverse ‘onion skin’ firing patterns, but this effect was reversed at high force levels. Significance. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.

  9. SU-F-T-67: Correction Factors for Monitor Unit Verification of Clinical Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Haywood, J [Mercy Health Partners, Muskegon, MI (United States)

    2016-06-15

    Purpose: Monitor units calculated by electron Monte Carlo treatment planning systems are often higher than TG-71 hand calculations for a majority of patients. Here I’ve calculated tables of geometry and heterogeneity correction factors for correcting electron hand calculations. Method: A flat water phantom with spherical volumes having radii ranging from 3 to 15 cm was created. The spheres were centered with respect to the flat water phantom, and all shapes shared a surface at 100 cm SSD. D{sub max} dose at 100 cm SSD was calculated for each cone and energy on the flat phantom and for the spherical volumes in the absence of the flat phantom. The ratio of dose in the sphere to dose in the flat phantom defined the geometrical correction factor. The heterogeneity factors were then calculated from the unrestricted collisional stopping power for tissues encountered in electron beam treatments. These factors were then used in patient second check calculations. Patient curvature was estimated by the largest sphere that aligns to the patient contour, and appropriate tissue density was read from the physical properties provided by the CT. The resulting MU were compared to those calculated by the treatment planning system and TG-71 hand calculations. Results: The geometry and heterogeneity correction factors range from ∼(0.8–1.0) and ∼(0.9–1.01) respectively for the energies and cones presented. Percent differences for TG-71 hand calculations drop from ∼(3–14)% to ∼(0–2)%. Conclusion: Monitor units calculated with the correction factors typically decrease the percent difference to under actionable levels, < 5%. While these correction factors work for a majority of patients, there are some patient anatomies that do not fit the assumptions made. Using these factors in hand calculations is a first step in bringing the verification monitor units into agreement with the treatment planning system MU.

  10. Rendez-vous avec les oeuvres du Musée: le speed dating au MAH : quinze minutes pour convaincre

    OpenAIRE

    Matthey, David

    2015-01-01

    Tiré du site internet du blog des Musées d'art et d'histoire (http://blog.mahgeneve.ch): "Lors des soirées Afterwork tenues au MAH durant les mois d'octobre et de novembre, les séances de speed dating – un commentaire d'une quinzaine de minutes consacré à une oeuvre ou à un ensemble d'oeuvres – ont remporté un franc succès. Cet engouement nous conforte dans l'idée d'en faire le fil rouge de nos futures manifestations de fin de journée ! Mais pourquoi cette formule?".

  11. Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-04-01

    This report presents the 2007 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. Requirements for CAU 443 are specified in the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada and includes groundwater monitoring in support of site closure. This is the first groundwater monitoring report prepared by DOE-LM for the CNTA The CNTA is located north of U.S. Highway 6, approximately 30 miles north of Warm Springs in Nye County, Nevada (Figure 1). Three emplacement boreholes, UC-1, UC-3, and UC-4, were drilled at the CNTA for underground nuclear weapons testing. The initial underground nuclear test, Project Faultless, was conducted in borehole UC-1 at a depth of 3,199 feet (ft) (975 meters) below ground surface on January 19, 1968. The yield of the Project Faultless test was estimated to be 0.2 to 1 megaton (DOE 2004). The test resulted in a down-dropped fault block visible at land surface (Figure 2). No further testing was conducted at the CNTA, and the site was decommissioned as a testing facility in 1973.

  12. ATP bioluminescence: Surface hygiene monitoring in milk preparation room of neonatal intensive care unit

    Science.gov (United States)

    Mohamad, Mahirah; Ishak, Shareena; Jaafar, Rohana; Sani, Norrakiah Abdullah

    2018-04-01

    ATP Bioluminescence application and standard microbiological analyses were used to evaluate the cleanliness of milk contact surfaces and non-milk contact surfaces in milk preparation room of neonatal intensive care unit (NICU) of Universiti Kebangsaan Malaysia Medical Centre (UKMMC). A total of 44 samples including the breast pump, milk bottle, milk bottle screw top and screw ring, teats, measuring cups, waterless warmer, refrigerator, dishwasher and pasteurizer inner wall were tested on May 2017. 3M Clean and Trace Hygiene Monitoring (UXL100 ATP Test swabs) and the bioluminescence reader Clean-Trace NG Luminometer (3M) were used to measure the Relative Light Unit (RLU) and microbiological analysis using 3M Quick Swab and 3MTM PetrifilmTM for enumeration of aerobic count, Staphylococcus aureus, Enterobacteriaceae, coliform and detection of Escherichia coli (CFU /100cm2 or utensil/item). The RLU values were from 11 to 194 and passed the ATP benchmark for intensive care unit (ICU), < 250 RLU as recommended. Aerobic colony count was only found in waterless warmer (0.05±0.01 mean log CFU/warmer). None of S. aureus, Enterobacteriaceae, E. coli and coliform was detected in all samples. A weak correlation was found between bioluminescence measurements RLU and the microbiological analysis (CFU). However, the use of ATP bioluminescence in monitoring milk preparation room cleanliness can be a useful method for assessing rapidly the surface hygiene as well as to verify the Sanitation Standard Operating Procedure (SSOP) prior to implementation of Hazard Analysis and Critical Control Points (HACCP) in milk preparation room.

  13. The design preparation for radiation monitoring system in the frame of completion NPP Mochovce Units 3 and 4

    International Nuclear Information System (INIS)

    Sevecka, S.; Slavik, O.; Kapisovsky, V.

    2009-01-01

    In 1985 a Basic Design of Radiation Monitoring System (RMS) has been elaborated for Mochovce NPP unit 3 and 4 construction. Due to construction interruption in the following years this design solution became obsolete. A new solution of RMS have been developed with conception following that of original Basic Design accommodating also safety measures implemented in RMS of NPP EMO units 1 and 2, and based on modem instrumentation and computer technique. Following the updating of Basic Design documentation the preparation of elaboration of RMS detailed design was carried on. In the frame of this preparation a review of possible suppliers of instrumentation satisfying the conception of radiation monitoring system and the extension of required deliveries has been made. Also criteria on RMS suppliers selection have been determined. The types of monitoring systems and equipment, as well as their quantities, have been specified based on updated Basic Design requirements and production profiles and possibilities of potential suppliers. The required parameters of measurements (including measurement geometry) have been evaluated, as well as requirements of legislation and requirements of proposed RMS architecture. (authors)

  14. Independent calculation of the monitor units and times of treatment in radiotherapy

    International Nuclear Information System (INIS)

    Mueller, Marcio Rogerio

    2005-01-01

    In this work, an independent verification system of calculations in radiotherapy was developed and applied, using Visual Basic TM programming language. The computational program performs calculations of monitor units and treatment time, based on the algorithm of manual calculation. The calculations executed for the independent system had initially been compared with the manual calculations performed by the medical physicists of the Institute of Radiotherapy of the Hospital das Clinicas da Universidade de Sao Paulo. In this step, the results found for more than two hundred fields studied were similar to those found in the literature; deviations larger than +- 1% were found only in five cases involving errors in manual calculation. The application of the independent system, in this stage, could have identified errors up to +- 2,4%. Based on these data, the system was validated for use in clinical routine. In a second step, calculations were compared with calculations realized by the treatment computerized planning system CadPIan TM . When, again, the results were similar to those published in other works allowing to obtain levels of acceptance of the discrepancies between the calculations executed for the independent system and the calculations developed from the planning system, separated by anatomical region, as recommended according by the recent literature. For beams of 6 MV, the levels of acceptance for deviations between the calculations of monitor units, separated by treatment region were the following; breast +- 1.7%, head and neck +2%; hypophysis +- 2.2%; pelvis +- 4 . 1% and thorax +- 1.5%. For beams of 15 MV, the level suggested for pelvis was of +- 4.5%. (author)

  15. Selective fatigue of fast motor units after electrically elicited muscle contractions.

    Science.gov (United States)

    Hamada, Taku; Kimura, Tetsuya; Moritani, Toshio

    2004-10-01

    The aim of the present study was to elucidate the electrophysiological manifestations of selective fast motor unit (MU) activation by electrical stimulation (ES) of knee extensor muscles. In six male subjects, test contraction measurement at 40% maximal voluntary contraction (MVC) was performed before and at every 5 min (5, 10, 15 and 20 min) during 20-min low intensity intermittent exercise of either ES or voluntary contractions (VC) at 10% MVC (5-s isometric contraction and 5-s rest cycles). Both isolated intramuscular MU spikes obtained from three sets of bipolar fine-wire electrodes and surface electromyogram (EMG) were simultaneously recorded and were analyzed by means of a computer-aided intramuscular spike amplitude-frequency analysis and frequency power spectral analysis, respectively. Results indicated that mean MU spike amplitude, particularly those MUs with relatively large amplitude, was significantly reduced while those MUs with small spike amplitude increased their firing rate during the 40% MVC test contraction after the ES. This was accompanied by the increased amplitude of surface EMG (rmsEMG). However, no such significant changes in the intramuscular and surface EMGs were observed after VC. These findings indicated differential MU activation patterns in terms of MU recruitment and rate coding characteristics during ES and VC, respectively. Our data strongly suggest the possibility of "an inverse size principle" of MU recruitment during ES.

  16. REAL-TIME ASSESSMENT OF MICROWAVE ABLATION EFFICACY BY NIR SPECTROSCOPIC TECHNIQUE

    Directory of Open Access Journals (Sweden)

    JINZHE ZHAO

    2014-01-01

    Full Text Available Microwave ablation (MWA status monitoring in real time plays a key role in assessment of therapeutic effectiveness. As a novel real-time assessment method, near infrared spectroscopy (NIRs was used to evaluate the ablation efficacy. MWA experiments were carried out on in vitro porcine livers. An optical measurement system for biological tissue is developed by our lab to monitor reduced scattering coefficient $(\\mu_{s}^{'}$ at 690 nm of the coagulation zones. It is noted that $\\mu_{s}^{'}$ of liver tissue, which increases as the liver tissue being ablated, is clearly related with the coagulation status. $\\mu_{s}^{'}$ of normal tissue and coagulated tissue is 3–5 and 17–19 cm-1, respectively. Continuous changes of $\\mu_{s}^{'}$ demonstrate that optical parameter can be used as an efficacy evaluation factor because it essentially indicates the degree of thermal damage. Compared with temperature, optical parameter is more sensitive and accurate, which is promising for real-time therapeutic efficacy assessment in MWA.

  17. Design description of a microprocessor based Engine Monitoring and Control unit (EMAC) for small turboshaft

    Science.gov (United States)

    Baez, A. N.

    1985-01-01

    Research programs have demonstrated that digital electronic controls are more suitable for advanced aircraft/rotorcraft turbine engine systems than hydromechanical controls. Commercially available microprocessors are believed to have the speed and computational capability required for implementing advanced digital control algorithms. Thus, it is desirable to demonstrate that off-the-shelf microprocessors are indeed capable of performing real time control of advanced gas turbine engines. The engine monitoring and control (EMAC) unit was designed and fabricated specifically to meet the requirements of an advanced gas turbine engine control system. The EMAC unit is fully operational in the Army/NASA small turboshaft engine digital research program.

  18. Application for verification of monitor units of the treatment planning system; Aplicacion para la verificacion de unidades monitor del sistema de planificacion de tratamientos

    Energy Technology Data Exchange (ETDEWEB)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-07-01

    Current estimates algorithms achieve acceptable degree of accuracy. However, operate on the basis of un intuitive models. It is therefore necessary to verify the calculation of monitor units of the treatment planning system (PTS) with those obtained by other independent formalisms. To this end, we have developed an application based on factorization formalism that automates the calculation of dose.

  19. Design of a microprocessor-based Control, Interface and Monitoring (CIM unit for turbine engine controls research

    Science.gov (United States)

    Delaat, J. C.; Soeder, J. F.

    1983-01-01

    High speed minicomputers were used in the past to implement advanced digital control algorithms for turbine engines. These minicomputers are typically large and expensive. It is desirable for a number of reasons to use microprocessor-based systems for future controls research. They are relatively compact, inexpensive, and are representative of the hardware that would be used for actual engine-mounted controls. The Control, Interface, and Monitoring Unit (CIM) contains a microprocessor-based controls computer, necessary interface hardware and a system to monitor while it is running an engine. It is presently being used to evaluate an advanced turbofan engine control algorithm.

  20. Micro-evolutionary divergence patterns of mandible shapes in wild house mouse (Mus musculus populations

    Directory of Open Access Journals (Sweden)

    Tautz Diethard

    2011-10-01

    Full Text Available Abstract Background Insights into the micro-evolutionary patterns of morphological traits require an assessment of the natural variation of the trait within and between populations and closely related species. The mouse mandible is a particularly suitable morphological trait for such an analysis, since it has long been used as a model to study the quantitative genetics of shape. In addition, many distinct populations, sub-species and closely related species are known for the house mouse. However, morphological comparisons among wild caught animals require an assessment in how far environmental and technical factors could interfere with the shape change measurements. Results Using geometric morphometrics, we have surveyed mandible shapes in 15 natural populations of the genus Mus, with a focus on the subspecies Mus musculus domesticus. In parallel we have carefully assessed possibly confounding technical and biological factors. We find that there are distinct differences on average between populations, subspecies and species, but these differences are smaller than differences between individuals within populations. Populations from summer-dry regions, although more ancestral, are less distinct from each other than are populations from the more recently colonized northern areas. Populations with especially distinct shapes occur in an area of sympatry of M. m. domesticus and M. spretus and on recently colonized sub-antarctic islands. We have also studied a number of inbred strains to assess in how far their mandible shapes resemble those from the wild. We find that they fall indeed into the shape space of natural variation between individuals in populations. Conclusions Although mandible shapes in natural populations can be influenced by environmental variables, these influences are insufficient to explain the average extent of shape differences between populations, such that evolutionary processes must be invoked to explain this level of diversity

  1. Evaluation of eleven years of area monitoring in ore treatment unit: I external exposure

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S.; Py Junior, D.A.; Oliveira, S.Q. de; Dantas, M.V.A., E-mail: pereiraws@gmail.com [Industrias Nucleares do Brasil (INB), Pocos de Caldas, MG (Brazil). Unidade de Tratamento de Minerio. Grupo Multidisciplinar de Radioprotecao; Kelecom, A., E-mail: akelecom@id.uff.br [Universidade Federal Fluminense (LARARA-PLS/GETA/UFF), Niteroi, RJ (Brazil). Laboratorio de Radiobiologia e Radiometria Pedro Lopes dos Santos. Grupo de Estudos em Temas Ambientais; Pereira, J.R.S., E-mail: pereirarsj@gmail.com [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil)

    2013-07-01

    The Ore Treatment Unit (OTU) is an uranium mining and milling complex deactivated in 1995 that operated monazite during the years 2004 and 2005 in a plant used especially for that purpose called Chemical Treatment of Monazite (CTM). This study aims to analyze the monitoring of area to exposure rate from 2002 to 2012, comparing periods of suspended operation of OTU and identifying the influences of CTM and of the radioactive waste deposit, from other facilities of OTU. A total of 22,294 samples were analyzed for area dose rates; average values were obtained of 6.74 μSv h{sup -1} with an amplitude from 0 to 420 μSv h{sup -1}. 92% of the monitoring were below the derivative limit for workers, and 1,702 monitoring samples showed values above this limit. Ignoring the monitoring that was realized at CTM and at the deposit of radioactive waste, the number of monitoring samples were reduced to 1,341. In this case, the average reduces to 0.96 μSv h{sup -1}, going from 0 to 25 μSv h{sup -1}, only 15 samples remained above the threshold for workers and 675 samples were below the limit for individual public. It can be concluded that the OTU is an installation with nearly 99% of monitoring area safe for workers and 50% for individual public. The inclusion of new practices (CTM) and the deposit of radioactive waste coming from other facilities alter this picture dramatically, increased the dose rates. (author)

  2. 78 FR 7411 - Vessel Monitoring Systems (VMS); Certification of New VMS Unit for Use in Northeast Fisheries

    Science.gov (United States)

    2013-02-01

    ... Monitoring Systems (VMS); Certification of New VMS Unit for Use in Northeast Fisheries AGENCY: National... used effective January 24, 2013. FOR FURTHER INFORMATION CONTACT: Office of Law Enforcement, Northeast Division, Northeast VMS Team, telephone 978-281-9213. SUPPLEMENTARY INFORMATION: Regulations at 50 CFR 648...

  3. Reassessment of Non-Monosynaptic Excitation from the Motor Cortex to Motoneurons in Single Motor Units of the Human Biceps Brachii.

    Science.gov (United States)

    Nakajima, Tsuyoshi; Tazoe, Toshiki; Sakamoto, Masanori; Endoh, Takashi; Shibuya, Satoshi; Elias, Leonardo A; Mezzarane, Rinaldo A; Komiyama, Tomoyoshi; Ohki, Yukari

    2017-01-01

    Corticospinal excitation is mediated by polysynaptic pathways in several vertebrates, including dexterous monkeys. However, indirect non-monosynaptic excitation has not been clearly observed following transcranial electrical stimulation (TES) or cervicomedullary stimulation (CMS) in humans. The present study evaluated indirect motor pathways in normal human subjects by recording the activities of single motor units (MUs) in the biceps brachii (BB) muscle. The pyramidal tract was stimulated with weak TES, CMS, and transcranial magnetic stimulation (TMS) contralateral to the recording side. During tasks involving weak co-contraction of the BB and hand muscles, all stimulation methods activated MUs with short latencies. Peristimulus time histograms (PSTHs) showed that responses with similar durations were induced by TES (1.9 ± 1.4 ms) and CMS (2.0 ± 1.4 ms), and these responses often showed multiple peaks with the PSTH peak having a long duration (65.3% and 44.9%, respectively). Such long-duration excitatory responses with multiple peaks were rarely observed in the finger muscles following TES or in the BB following stimulation of the Ia fibers. The responses obtained with TES were compared in the same 14 BB MUs during the co-contraction and isolated BB contraction tasks. Eleven and three units, respectively, exhibited activation with multiple peaks during the two tasks. In order to determine the dispersion effects on the axon conduction velocities (CVs) and synaptic noise, a simulation study that was comparable to the TES experiments was performed with a biologically plausible neuromuscular model. When the model included the monosynaptic-pyramidal tract, multiple peaks were obtained in about 34.5% of the motoneurons (MNs). The experimental and simulation results indicated the existence of task-dependent disparate inputs from the pyramidal tract to the MNs of the upper limb. These results suggested that intercalated interneurons are present in the spinal cord and

  4. Reassessment of Non-Monosynaptic Excitation from the Motor Cortex to Motoneurons in Single Motor Units of the Human Biceps Brachii

    Science.gov (United States)

    Nakajima, Tsuyoshi; Tazoe, Toshiki; Sakamoto, Masanori; Endoh, Takashi; Shibuya, Satoshi; Elias, Leonardo A.; Mezzarane, Rinaldo A.; Komiyama, Tomoyoshi; Ohki, Yukari

    2017-01-01

    Corticospinal excitation is mediated by polysynaptic pathways in several vertebrates, including dexterous monkeys. However, indirect non-monosynaptic excitation has not been clearly observed following transcranial electrical stimulation (TES) or cervicomedullary stimulation (CMS) in humans. The present study evaluated indirect motor pathways in normal human subjects by recording the activities of single motor units (MUs) in the biceps brachii (BB) muscle. The pyramidal tract was stimulated with weak TES, CMS, and transcranial magnetic stimulation (TMS) contralateral to the recording side. During tasks involving weak co-contraction of the BB and hand muscles, all stimulation methods activated MUs with short latencies. Peristimulus time histograms (PSTHs) showed that responses with similar durations were induced by TES (1.9 ± 1.4 ms) and CMS (2.0 ± 1.4 ms), and these responses often showed multiple peaks with the PSTH peak having a long duration (65.3% and 44.9%, respectively). Such long-duration excitatory responses with multiple peaks were rarely observed in the finger muscles following TES or in the BB following stimulation of the Ia fibers. The responses obtained with TES were compared in the same 14 BB MUs during the co-contraction and isolated BB contraction tasks. Eleven and three units, respectively, exhibited activation with multiple peaks during the two tasks. In order to determine the dispersion effects on the axon conduction velocities (CVs) and synaptic noise, a simulation study that was comparable to the TES experiments was performed with a biologically plausible neuromuscular model. When the model included the monosynaptic-pyramidal tract, multiple peaks were obtained in about 34.5% of the motoneurons (MNs). The experimental and simulation results indicated the existence of task-dependent disparate inputs from the pyramidal tract to the MNs of the upper limb. These results suggested that intercalated interneurons are present in the spinal cord and

  5. Monitoring of health care personnel employee and occupational health immunization program practices in the United States.

    Science.gov (United States)

    Carrico, Ruth M; Sorrells, Nikka; Westhusing, Kelly; Wiemken, Timothy

    2014-01-01

    Recent studies have identified concerns with various elements of health care personnel immunization programs, including the handling and management of the vaccine. The purpose of this study was to assess monitoring processes that support evaluation of the care of vaccines in health care settings. An 11-question survey instrument was developed for use in scripted telephone surveys. State health departments in all 50 states in the United States and the District of Columbia were the target audience for the surveys. Data from a total of 47 states were obtained and analyzed. No states reported an existing monitoring process for evaluation of health care personnel immunization programs in their states. Our assessment indicates that vaccine evaluation processes for health care facilities are rare to nonexistent in the United States. Identifying existing practice gaps and resultant opportunities for improvements may be an important safety initiative that protects patients and health care personnel. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  6. The Epimed Monitor ICU Database®: a cloud-based national registry for adult intensive care unit patients in Brazil.

    Science.gov (United States)

    Zampieri, Fernando Godinho; Soares, Márcio; Borges, Lunna Perdigão; Salluh, Jorge Ibrain Figueira; Ranzani, Otávio Tavares

    2017-01-01

    To describe the Epimed Monitor Database®, a Brazilian intensive care unit quality improvement database. We described the Epimed Monitor® Database, including its structure and core data. We presented aggregated informative data from intensive care unit admissions from 2010 to 2016 using descriptive statistics. We also described the expansion and growth of the database along with the geographical distribution of participating units in Brazil. The core data from the database includes demographic, administrative and physiological parameters, as well as specific report forms used to gather detailed data regarding the use of intensive care unit resources, infectious episodes, adverse events and checklists for adherence to best clinical practices. As of the end of 2016, 598 adult intensive care units in 318 hospitals totaling 8,160 intensive care unit beds were participating in the database. Most units were located at private hospitals in the southeastern region of the country. The number of yearly admissions rose during this period and included a predominance of medical admissions. The proportion of admissions due to cardiovascular disease declined, while admissions due to sepsis or infections became more common. Illness severity (Simplified Acute Physiology Score - SAPS 3 - 62 points), patient age (mean = 62 years) and hospital mortality (approximately 17%) remained reasonably stable during this time period. A large private database of critically ill patients is feasible and may provide relevant nationwide epidemiological data for quality improvement and benchmarking purposes among the participating intensive care units. This database is useful not only for administrative reasons but also for the improvement of daily care by facilitating the adoption of best practices and use for clinical research.

  7. Recommended methods for range-wide monitoring of prairie dogs in the United States

    Science.gov (United States)

    McDonald, Lyman L.; Stanley, Thomas R.; Otis, David L.; Biggins, Dean E.; Stevens, Patricia D.; Koprowski, John L.; Ballard, Warren

    2011-01-01

    One of the greatest challenges for conserving grassland, prairie scrub, and shrub-steppe ecosystems is maintaining prairie dog populations across the landscape. Of the four species of prairie dogs found in the United States, the Utah prairie dog (Cynomys parvidens) is listed under the Endangered Species Act (ESA) as threatened, the Gunnison's prairie dog (C. gunnisoni) is a candidate for listing in a portion of its range, and the black-tailed prairie dog (C. ludovicianus) and white-tailed prairie dog (C. leucurus) have each been petitioned for listing at least once in recent history. Although the U.S. Fish and Wildlife Service (USFWS) determined listing is not warranted for either the black-tailed prairie dog or white-tailed prairie dog, the petitions and associated reviews demonstrated the need for the States to monitor and manage for self-sustaining populations. In response to these findings, a multi-State conservation effort was initiated for the nonlisted species which included the following proposed actions: (1) completing an assessment of each prairie dog species in each State, (2) developing a range-wide monitoring protocol for each species using a statistically valid sampling procedure that would allow comparable analyses across States, and (3) monitoring prairie dog status every 3-5 years depending upon the species. To date, each State has completed an assessment and currently is monitoring prairie dog status; however, for some species, the inconsistency in survey methodology has made it difficult to compare data year-to-year or State-to-State. At the Prairie Dog Conservation Team meeting held in November 2008, there was discussion regarding the use of different methods to survey prairie dogs. A recommendation from this meeting was to convene a panel in a workshop-type forum and have the panel review the different methods being used and provide recommendations for range-wide monitoring protocols for each species of prairie dog. Consequently, the Western

  8. Development of Product Availability Monitoring System In Production Unit In Automotive Component Industry

    Science.gov (United States)

    Hartono, Rachmad; Raharno, Sri; Yuwana Martawirya, Yatna; Arthaya, Bagus

    2018-03-01

    This paper described a methodology to monitor the availability of products in a production unit in the automotive component industry. Automotive components made are automotive components made through sheet metal working. Raw material coming into production unit in the form of pieces of plates that have a certain size. Raw materials that come stored in the warehouse. Data of raw each material in the warehouse are recorded and stored in a data base system. The material will then undergo several production processes in the production unit. When the material is taken from the warehouse, material data are also recorded and stored in a data base. The data recorded are the amount of material, material type, and date when the material is out of the warehouse. The material coming out of the warehouse is labeled with information related to the production processes that the material must pass. Material out of the warehouse is a product will be made. The products have been completed, are stored in the warehouse products. When the product is entered into the product warehouse, product data is also recorded by scanning the barcode contained on the label. By recording the condition of the product at each stage of production, we can know the availability of the product in a production unit in the form of a raw material, the product being processed and the finished product.

  9. Drosophila mutations at the mei-9 and mus(2)201 loci which block excision of thymine dimers also block induction of unscheluded DNA synthesis by methyl methanesulfonate, ethyl methanesulfonate, N-methyl-N-nitrosourea, UV light and X-rays

    International Nuclear Information System (INIS)

    Dusenbery, R.L.; McCormick, S.C.; Smith, P.D.

    1983-01-01

    The mei-9 and mus(2)201 mutants of Drosophila melanogaster were identified as mutagen-sensitive mutants on the basis of larval hypersensitivity to methyl methanesulfonate and characterized as excision repair-deficient on the basis of a greatly reduced capacity to excise thymine dimers from cellular DNA. The high degree of larval cytotoxicity observed with a variety of other chemical and physical agents indicated that these mutants may be unable to excise other important classes of DNA adducts. We have measured the ability of the single mutants and the double mutant combination mei-9;mus(2)201 to perform the resynthesis step in excision repair by means of an autoradiographic analysis of unscheduled DNA synthesis (UDS) induced in a mixed population of primary cells in culture. The 3 strains exhibit no detectable UDS activity in response to applied doses of 1.5-6.0 mM methyl methanesulfonate, 1.0-4.5 nM N-methyl-N-nitrosourea or 10-40 J/m 2 254-nm UV light, dose ranges in which control cells exhibit a strong dose-dependent UDS response. The mei-9 and mei-9;mus(2)201 mutants also have no detectable UDS response to X-ray doses of 300-1.800 rad, whereas the mus(2)201 mutant exhibits a reduced, but dose-dependent, response over this range. These data correlate well with the degree of larval hypersensitivity of the strains and suggest that mutations at both loci block the excision repair of a wide variety of DNA damage prior to the resynthesis step. (orig.)

  10. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas

    International Nuclear Information System (INIS)

    1990-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1990 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory -- Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release

  11. Development of expert system for fuel monitoring and analysis in WWER-1000 units

    International Nuclear Information System (INIS)

    Likhanskii, V.; Evdokimov, I.; Sorokin, A.; Kanukova, V.; Zborovskii, V.; Aliev, T.; Sokolov, N.; Shishkin, A.

    2011-01-01

    At present, an expert system (software package) for fuel monitoring in WWER units is under development in Russia. It comprises several modules which cover analysis of coolant activity, detection of failures and estimation of failure parameters, predictions of activity level and some aspects of PCI analysis. This paper outlines the current version of the fuel monitoring system, its basic features and user interface. Advances in development of computer modules for PCI analysis are reported. At present two levels of PCI analysis are used. The first is estimation of probability for pellets to get in contact with cladding in fuel rods. Estimations are made with taking into account specifications and tolerances for fuel fabrication as well as fuel operation conditions. The second level of PCI analysis implies a simplified approach for on-line calculations of stresses in cladding depending on power ramping rates. The model for PCI calculations and its application within the computer system is demonstrated. (authors)

  12. Patterns of genetic differentiation at MHC class I genes and microsatellites identify conservation units in the giant panda.

    Science.gov (United States)

    Zhu, Ying; Wan, Qiu-Hong; Yu, Bin; Ge, Yun-Fa; Fang, Sheng-Guo

    2013-10-22

    Evaluating patterns of genetic variation is important to identify conservation units (i.e., evolutionarily significant units [ESUs], management units [MUs], and adaptive units [AUs]) in endangered species. While neutral markers could be used to infer population history, their application in the estimation of adaptive variation is limited. The capacity to adapt to various environments is vital for the long-term survival of endangered species. Hence, analysis of adaptive loci, such as the major histocompatibility complex (MHC) genes, is critical for conservation genetics studies. Here, we investigated 4 classical MHC class I genes (Aime-C, Aime-F, Aime-I, and Aime-L) and 8 microsatellites to infer patterns of genetic variation in the giant panda (Ailuropoda melanoleuca) and to further define conservation units. Overall, we identified 24 haplotypes (9 for Aime-C, 1 for Aime-F, 7 for Aime-I, and 7 for Aime-L) from 218 individuals obtained from 6 populations of giant panda. We found that the Xiaoxiangling population had the highest genetic variation at microsatellites among the 6 giant panda populations and higher genetic variation at Aime-MHC class I genes than other larger populations (Qinling, Qionglai, and Minshan populations). Differentiation index (FST)-based phylogenetic and Bayesian clustering analyses for Aime-MHC-I and microsatellite loci both supported that most populations were highly differentiated. The Qinling population was the most genetically differentiated. The giant panda showed a relatively higher level of genetic diversity at MHC class I genes compared with endangered felids. Using all of the loci, we found that the 6 giant panda populations fell into 2 ESUs: Qinling and non-Qinling populations. We defined 3 MUs based on microsatellites: Qinling, Minshan-Qionglai, and Daxiangling-Xiaoxiangling-Liangshan. We also recommended 3 possible AUs based on MHC loci: Qinling, Minshan-Qionglai, and Daxiangling-Xiaoxiangling-Liangshan. Furthermore, we recommend

  13. Emittance measuring unit for 100% duty factor linac injector beams

    Energy Technology Data Exchange (ETDEWEB)

    Shubaly, M R; Pachner, J Jr; Ormrod, J H; Ungrin, J; Schriber, S O [ed.

    1976-11-01

    A description is given of a system to measure the emittance of a 750 keV 100 mA dc proton beam suitable for injection into a 100% duty factor linear accelerator. A relatively slowly pulsed 45/sup 0/ magnet switches the beam to a beam dump inside the emittance measuring unit for approx. 10 s. A fast pulsed 5/sup 0/ magnet then deflects the beam to a multiple aperture ''pepper-pot'' plate for 300 ..mu..s. Beamlets passing through the plate travel 520 mm and produce a pattern on a scintillator screen. A photograph of the pattern is analyzed to determine beam emittance. Preliminary results on low current beams show a gross increase in the emittance in the horizontal plane.

  14. The Southeastern Asian house mouse (Mus musculus castaneus Linn.) as a new passenger host for Cryptococcus neoformans var. grubii molecular type VNI.

    Science.gov (United States)

    Singh, Karuna; Rani, Jyoti; Neelabh; Rai, Govind Kumar; Singh, Major

    2017-11-01

    We describe Mus musculus castaneus as a new mammalian host for Cryptococcus neoformans var. grubii (VNI). Eighteen apparently healthy adults and pups of the rodent were collected from human dwellings in Varanasi, a city of India. Both clinical and behavioral examinations of the rodents did not reveal any sign of the disease. Among visceral organs, histological examination of only liver exhibited the presence of single celled, encapsulated, Southgate's mucicarmine positive fungal structures consistent with C. neoformans. Nevertheless, culture of tissue homogenates of brain, lungs, liver, and kidneys yielded white colonies on Sabouraud's dextrose agar and brown mucoid colonies of C. neoformans on Staib's and Tobacco agar media. The pathogen was isolated from habitat soil as well as fresh faeces of the animals. All isolates were urease positive, nitrate and canavanine-glycine bromothymol blue negative, exhibited phenoloxidase activity and grew at 37°C. The isolates were identified as C. neoformans var. grubii with ITS primers and unique marker (GACA)4. The pathogen when inoculated in immunosuppressed mice showed low pathogenicity. To our knowledge, we for the first time report case cluster of Mus musculus castaneus as new passenger host for C. neoformans var. grubii (VNI). © The Author 2017. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Peroral Echinococcus multilocularis egg inoculation in Myodes glareolus, Mesocricetus auratus and Mus musculus (CD-1 IGS and C57BL/6j)

    DEFF Research Database (Denmark)

    Woolsey, Ian David; Jensen, Per Moestrup; Deplazes, Peter

    2016-01-01

    Echinococcus multilocularis transmission predominantly occurs in Europe between the red fox (Vulpes vulpes) and various species of rodent intermediate hosts. We infected 3 species of rodent, Myodes glareolus (n = 47), Mesocricetus auratus (n = 11) and outbred Mus musculus (CD-1 IGS) (n = 9...

  16. Changes in motor unit behavior following isometric fatigue of the first dorsal interosseous muscle

    Science.gov (United States)

    Rymer, William Z.; Lowery, Madeleine M.; Suresh, Nina L.

    2015-01-01

    The neuromuscular strategies employed to compensate for fatigue-induced muscle force deficits are not clearly understood. This study utilizes surface electromyography (sEMG) together with recordings of a population of individual motor unit action potentials (MUAPs) to investigate potential compensatory alterations in motor unit (MU) behavior immediately following a sustained fatiguing contraction and after a recovery period. EMG activity was recorded during abduction of the first dorsal interosseous in 12 subjects at 20% maximum voluntary contraction (MVC), before and directly after a 30% MVC fatiguing contraction to task failure, with additional 20% MVC contractions following a 10-min rest. The amplitude, duration and mean firing rate (MFR) of MUAPs extracted with a sEMG decomposition system were analyzed, together with sEMG root-mean-square (RMS) amplitude and median frequency (MPF). MUAP duration and amplitude increased immediately postfatigue and were correlated with changes to sEMG MPF and RMS, respectively. After 10 min, MUAP duration and sEMG MPF recovered to prefatigue values but MUAP amplitude and sEMG RMS remained elevated. MU MFR and recruitment thresholds decreased postfatigue and recovered following rest. The increase in MUAP and sEMG amplitude likely reflects recruitment of larger MUs, while recruitment compression is an additional compensatory strategy directly postfatigue. Recovery of MU MFR in parallel with MUAP duration suggests a possible role for metabolically sensitive afferents in MFR depression postfatigue. This study provides insight into fatigue-induced neuromuscular changes by examining the properties of a large population of concurrently recorded single MUs and outlines possible compensatory strategies involving alterations in MU recruitment and MFR. PMID:25761952

  17. The uncharacterized gene 1700093K21Rik and flanking regions are correlated with reproductive isolation in the house mouse, Mus musculus.

    Science.gov (United States)

    Kass, David H; Janoušek, Václav; Wang, Liuyang; Tucker, Priscilla K

    2014-06-01

    Reproductive barriers exist between the house mouse subspecies, Mus musculus musculus and M. m. domesticus, members of the Mus musculus species complex, primarily as a result of hybrid male infertility, and a hybrid zone exists where their ranges intersect in Europe. Using single nucleotide polymorphisms (SNPs) diagnostic for the two taxa, the extent of introgression across the genome was previously compared in these hybrid populations. Sixty-nine of 1316 autosomal SNPs exhibited reduced introgression in two hybrid zone transects suggesting maladaptive interactions among certain loci. One of these markers is within a region on chromosome 11 that, in other studies, has been associated with hybrid male sterility of these subspecies. We assessed sequence variation in a 20 Mb region on chromosome 11 flanking this marker, and observed its inclusion within a roughly 150 kb stretch of DNA showing elevated sequence differentiation between the two subspecies. Four genes are associated with this genomic subregion, with two entirely encompassed. One of the two genes, the uncharacterized 1700093K21Rik gene, displays distinguishing features consistent with a potential role in reproductive isolation between these subspecies. Along with its expression specifically within spermatogenic cells, we present various sequence analyses that demonstrate a high rate of molecular evolution of this gene, as well as identify a subspecies amino acid variant resulting in a structural difference. Taken together, the data suggest a role for this gene in reproductive isolation.

  18. Importance of scatter compensation algorithm in heterogeneous tissue for the radiation dose calculation of small lung nodules. A clinical study

    International Nuclear Information System (INIS)

    Baba, Yuji; Murakami, Ryuji; Mizukami, Naohisa; Morishita, Shoji; Yamashita, Yasuyuki; Araki, Fujio; Moribe, Nobuyuki; Hirata, Yukinori

    2004-01-01

    The purpose of this study was to compare radiation doses of small lung nodules calculated with beam scattering compensation and those without compensation in heterogeneous tissues. Computed tomography (CT) data of 34 small (1-2 cm: 12 nodules, 2-3 cm 11 nodules, 3-4 cm 11 nodules) lung nodules were used in the radiation dose measurements. Radiation planning for lung nodule was performed with a commercially available unit using two different radiation dose calculation methods: the superposition method (with scatter compensation in heterogeneous tissues), and the Clarkson method (without scatter compensation in heterogeneous tissues). The energy of the linac photon used in this study was 10 MV and 4 MV. Monitor unit (MU) to deliver 10 Gy at the center of the radiation field (center of the nodule) calculated with the two methods were compared. In 1-2 cm nodules, MU calculated by Clarkson method (MUc) was 90.0±1.1% (4 MV photon) and 80.5±2.7% (10 MV photon) compared to MU calculated by superposion method (MUs), in 2-3 cm nodules, MUc was 92.9±1.1% (4 MV photon) and 86.6±2.8% (10 MV photon) compared to MUs, and in 3-4 cm nodules, MUc was 90.5±2.0% (4 MV photon) and 90.1±1.7% (10 MV photon) compared to MUs. In 1-2 cm nodules, MU calculated without lung compensation (MUn) was 120.6±8.3% (4 MV photon) and 95.1±4.1% (10 MV photon) compared to MU calculated by superposion method (MUs), in 2-3 cm nodules, MUc was 120.3±11.5% (4 MV photon) and 100.5±4.6% (10 MV photon) compared to MUs, and in 3-4 cm nodules, MUc was 105.3±9.0% (4 MV photon) and 103.4±4.9% (10 MV photon) compared to MUs. The MU calculated without lung compensation was not significantly different from the MU calculated by superposition method in 2-3 cm nodules. We found that the conventional dose calculation algorithm without scatter compensation in heterogeneous tissues substantially overestimated the radiation dose of small nodules in the lung field. In the calculation of dose distribution of small

  19. Nuclear reactor instrumentation power monitor

    International Nuclear Information System (INIS)

    Suzuki, Shigeru.

    1989-01-01

    The present invention concerns a nuclear reactor instrumentation power monitor that can be used in, for example, BWR type nuclear power plants. Signals from multi-channel detectors disposed on field units are converted respectively by LPRM signal circuits. Then, the converted signals are further converted by a multiplexer into digital signals and transmitted as serial data to a central monitor unit. The thus transmitted serial data are converted into parallel data in the signal processing section of the central monitor unit. Then, LPRM signals are taken out from each of channel detectors to conduct mathematical processing such as trip judgment or averaging. Accordingly, the field unit and the central monitor unit can be connected by way of only one data transmission cable thereby enabling to reduce the number of cables. Further, since the data are transmitted on digital form, it less undergoes effect of noises. (I.S.)

  20. Design of an integrated sensor platform for vital sign monitoring of newborn infants at neonatal intensive care unit

    NARCIS (Netherlands)

    Chen, W.; Bambang Oetomo, S.; Feijs, L.M.G.; Bouwstra, S.; Ayoola, Idowu; Dols, S.A.E.

    2010-01-01

    Continuous health status monitoring and advances in medical treatments have resulted in a significant increase of survival rate in critically ill infants admitted into Neonatal Intensive Care Units (NICUs). The quality of life and long-term health prospects of the neonates depend increasingly on the

  1. Hubungan Hiperglikemia dengan Prothrombin Time pada Mencit (Mus musculus yang Diinduksi Aloksan

    Directory of Open Access Journals (Sweden)

    Muhammad Ibnu Malik

    2015-01-01

    . Endothelial disfungtion can be detected by activated partial thromboplastin time (APTT and prothrombin time (PT. The objective of this studi was to determine the correlation between hyperglycemia and prothrombin time in mice (Mus musculus induced with aloxan. The design of this research was a post test only control group design conducted in October 2013 until February 2014 in Central Laboratory RS Dr. M. Djamil Padang. The subject were white mice (Mus musculus who have met the inclusion and exclusion criteria. The subject were divided as hyperglycemia group (induced with aloxan and control group. After seven days of adaptation, the aloxan was injected and measurenment of blood glucose and body weight had been done, one time in every four days. Then in day 30th the termination of mice had been done to meassure the prothrombin time. The result showed the prothrombin time between group was shortened with the average prothrombin time of the control group was 7,96 second and the hiperglicemia group was 8,12 second. The result showing no correlation between hyperglycemia and prothrombin time with the degree of signification is (p 0,7 (p > 0,05.Keywords: hyperglycemia, diabetes mellitus, prothrombin time,

  2. 1988 Monitoring Activities Review (MAR) of the environmental monitoring program

    International Nuclear Information System (INIS)

    1989-03-01

    The EGandG Idaho Environmental Monitoring (EM) Unit is responsible for coordinating and conducting environmental measurements of radioactive and hazardous contaminants around facilities operated by EGandG Idaho. The EM Unit has several broad program objectives, which include complying with regulatory standards and developing a basis for estimating future impacts of operations at EGandG Idaho facilities. To improve program planning and to provide bases for technical improvement of the monitoring program, the EGandG Environmental Monitoring organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. Previous MAR studies have focused on procedures for all currently monitored media except biota. Biotic monitoring was initiated following the last MAR. This report focuses on all currently monitored media, and includes the first review of biotic monitoring. The review of biotic monitoring has been conducted at a level of detail consistent with initial MAR reports for other parts of the Waste Management Program Facilities Environmental Monitoring Program. The review of the biotic monitoring activities is presented in Section 5.5 of this report. 21 refs., 7 figs., 4 tabs

  3. A new device for monitoring moorings

    Digital Repository Service at National Institute of Oceanography (India)

    Namboothiri, E.G.; Krishnakumar, V.

    A new device - Mooring Monitoring Unit (MMU), which consists of an inwater unit and a deck unit has been designed to monitor mooring in situ. This device helps tracing underwater moorings, once its marker buoy is removed either by accident or theft...

  4. MercNet: A national monitoring network to assess responses to changing mercury emissions in the United States

    Science.gov (United States)

    Schmeltz, D.; Evers, D.C.; Driscoll, C.T.; Artz, R.; Cohen, M.; Gay, D.; Haeuber, R.; Krabbenhoft, D.P.; Mason, R.; Morris, K.; Wiener, J.G.

    2011-01-01

    A partnership of federal and state agencies, tribes, industry, and scientists from academic research and environmental organizations is establishing a national, policy-relevant mercury monitoring network, called MercNet, to address key questions concerning changes in anthropogenic mercury emissions and deposition, associated linkages to ecosystem effects, and recovery from mercury contamination. This network would quantify mercury in the atmosphere, land, water, and biota in terrestrial, freshwater, and coastal ecosystems to provide a national scientific capability for evaluating the benefits and effectiveness of emission controls. Program development began with two workshops, convened to establish network goals, to select key indicators for monitoring, to propose a geographic network of monitoring sites, and to design a monitoring plan. MercNet relies strongly on multi-institutional partnerships to secure the capabilities and comprehensive data that are needed to develop, calibrate, and refine predictive mercury models and to guide effective management. Ongoing collaborative efforts include the: (1) development of regional multi-media databases on mercury in the Laurentian Great Lakes, northeastern United States, and eastern Canada; (2) syntheses and reporting of these data for the scientific and policy communities; and (3) evaluation of potential monitoring sites. The MercNet approach could be applied to the development of other monitoring programs, such as emerging efforts to monitor and assess global mercury emission controls. ?? 2011 Springer Science+Business Media, LLC (outside the USA).

  5. Monitoring of operating processes

    International Nuclear Information System (INIS)

    Barry, R.F.

    1981-01-01

    Apparatus is described for monitoring the processes of a nuclear reactor to detect off-normal operation of any process and for testing the monitoring apparatus. The processes are evaluated by response to their paramters, such as temperature, pressure, etc. The apparatus includes a pair of monitoring paths or signal processing units. Each unit includes facilities for receiving on a time-sharing basis, a status binary word made up of digits each indicating the status of a process, whether normal or off-normal, and test-signal binary words simulating the status binary words. The status words and test words are processed in succession during successive cycles. During each cycle, the two units receive the same status word and the same test word. The test words simulate the status words both when they indicate normal operation and when they indicate off-normal operation. Each signal-processing unit includes a pair of memories. Each memory receives a status word or a test word, as the case may be, and converts the received word into a converted status word or a converted test word. The memories of each monitoring unit operate into a non-coincidence which signals non-coincidence of the converted word out of one memory of a signal-processing unit not identical to the converted word of the other memory of the same unit

  6. Validation of dynamic MLC-controller log files using a two-dimensional diode array

    International Nuclear Information System (INIS)

    Li, Jonathan G.; Dempsey, James F.; Ding Li; Liu, Chihray; Palta, Jatinder R.

    2003-01-01

    Intensity-modulated radiation therapy (IMRT) delivered with multi-leaf collimator (MLC) in the step-and-shoot mode uses multiple static MLC segments to achieve intensity modulation. For typical IMRT treatment plans, significant numbers of segments are delivered with monitor units (MUs) of much less than 10. Verification of the ability of the linear accelerator (linac) to deliver small MU segments accurately is an important step in the IMRT commissioning and quality assurance (QA) process. Recent studies have reported large discrepancies between the intended and delivered segment MUs. These discrepancies could potentially cause large errors in the delivered patient dose. We have undertaken a systematic study to evaluate the accuracy of the dynamic MLC log files, which are created automatically by our commercial MLC workstation after each delivery, in recording the fractional MU delivered in the step-and-shoot mode. Two linac models were evaluated with simple-geometry leaf sequences and delivered with different total MUs and different nominal dose rates. A commercial two-dimensional diode array was used for the measurement. Large discrepancies between the intended and delivered segment MUs were found. The discrepancies were larger for small MU segments at higher dose rate, with some small MU segments completely undelivered. The recorded fractional MUs in the log files were found to agree with what was delivered within the limits of our experimental uncertainty. Our results indicate that it is important to verify the delivery accuracy of small MU segments that could potentially occur in a patient treatment and that the log files are useful in checking the integrity of the linac delivery once validated. Thus validated log files can be used as a QA tool for general IMRT delivery and patient-specific plan verification

  7. Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

    Science.gov (United States)

    Rizos, Timolaos; Güntner, Janina; Jenetzky, Ekkehart; Marquardt, Lars; Reichardt, Christine; Becker, Rüdiger; Reinhardt, Roland; Hepp, Thomas; Kirchhof, Paulus; Aleynichenko, Elena; Ringleb, Peter; Hacke, Werner; Veltkamp, Roland

    2012-10-01

    Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxAF detection. Patients with acute ischemic stroke or transient ischemic attack were prospectively enrolled. After a 12-channel ECG on admission, all patients received 24-hour Holter ECG and CEM. Additionally, ECG monitoring data underwent automated analysis using dedicated software to identify pxAF. Patients with a history of atrial fibrillation or with atrial fibrillation on the admission ECG were excluded. Four hundred ninety-six patients (median age, 69 years; 61.5% male) fulfilled all inclusion criteria (ischemic stroke: 80.4%; transient ischemic attack: 19.6%). Median stroke unit stay lasted 88.8 hours (interquartile range, 65.0-122.0). ECG data for automated CEM analysis were available for a median time of 64.0 hours (43.0-89.8). Paroxysmal AF was documented in 41 of 496 patients (8.3%). Of these, Holter detected pxAF in 34.1%; CEM in 65.9%; and automated CEM in 92.7%. CEM and automated CEM detected significantly more patients with pxAF than Holter (Pstroke on stroke units compared with 24-hour Holter ECG. The comparative usefulness of prolonged or repetitive Holter ECG recordings requires further evaluation.

  8. Requirements for internal contamination monitoring units; Anforderungen an Inkorporationsmessstellen

    Energy Technology Data Exchange (ETDEWEB)

    Werner, E. [GSF, Inst. fuer Biophysikalische Strahlenforschung, Frankfurt am Main (Germany); Beyer, D. [Forschungszentrum Juelich, Abt. ASS (Germany); Doerfel, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany); Erlenbach, H. [Zentralstelle fuer Sicherheitstechnik NRW, Duesseldorf (Germany); Fischbach, G. [Siemens Brennelementewerk, Hanau (Germany); Henrichs, K. [Siemens AG, Muenchen (Germany); Keller, K.D. [Radiologische Universitaetsklinik, Tuebingen (Germany); Koenig, K. [Bundesamt fuer Strahlenschutz, ISH, Neuherberg (Germany); Riedel, W. [Freie Univ. Berlin, Klinikum Steglitz (Germany); Scheler, R. [Bundesamt fuer Strahlenschutz, FB Strahlenschutz, Berlin (Germany); Schieferdecker, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany)

    1994-12-31

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [Deutsch] Zur Ermittlung der Koerperdosen nach Paragraph 63 StrlSchV sind fuer die gemaess Abs. 6 von der zustaendigen Behoerde zu bestimmenden Messstellen in einer Richtlinie einheitliche Anforderungen festzulegen. Diese beziehen sich auf deren Ausstattung, die Durchfuehrung der Messungen, Auswertungen und Qualitaetskontrollen sowie die Aufzeichnung und Uebermittlung der Ergebnisse. Die Aufgaben der Messstellen umfassen die Messungen der Radioaktivitaet im Koerper bzw. in Koerperausscheidungen, die Ermittlung der Zufuhr an Radionukliden sowie der daraus resultierenden Koerperdosis und die Weiterleitung der Ergebnisse an den Auftraggeber, an das zentrale Dosisregister und in bestimmten Faellen an die Behoerde. Zu den von einer Messstelle zu erfuellenden Anforderungen gehoeren eine ausreichende Messeffektivitaet, die Durchfuehrung von Eigenkontrollen

  9. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    Science.gov (United States)

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  10. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  11. Detailed ordering of markers localizing to the Xq26-Xqter region of the human X chromosome by the use of an interspecific Mus spretus mouse cross

    International Nuclear Information System (INIS)

    Avner, P.; Amar, L.; Arnaud, D.; Hanauer, A.; Cambrou, J.

    1987-01-01

    Five probes localizing to the Xq26-Xqter region of the human X chromosome have been genetically mapped on the mouse X chromosome using an interspecific cross involving Mus spretus to a contiguous region lying proximally to the Tabby (Ta) locus. Pedigree and recombinational analysis establish the marker order as being Hprt-FIX-c11-G6PD-St14-1. The size of this contiguous region is such that the X-linked muscular dystrophy (mdx) mouse mutation probably maps within this segment. This in turn suggests that it is highly improbable that the mouse mdx locus represents a model for Duchenne muscular dystrophy (DMD). It is, however, compatible with the idea that this mutation may correspond in man to Emery Dreifuss muscular dystrophy. The high frequency of restriction fragment length polymorphisms found in this interspecific system for all the human cross-reacting probes examined up until now, using only a limited number of restriction enzymes, suggests that the Mus spretus mapping system may be of great potential value for establishing the linkage relationships existing in man when conserved chromosomal regions are concerned and human/mouse cross-reacting probes are available or can be obtained

  12. Alternative Site Technology Deployment-Monitoring System for the U-3ax/bl Disposal Unit at the Nevada Test Site

    International Nuclear Information System (INIS)

    Dixon, J.M.; Levitt, D.G.; Rawlinson, S.E.

    2001-01-01

    In December 2000, a performance monitoring facility was constructed adjacent to the U-3ax/bl mixed waste disposal unit at the Nevada Test Site (NTS). Recent studies conducted in the arid southwestern United States suggest that a vegetated monolayer evapotranspiration (ET) closure cover may be more effective at isolating waste than traditional Resource Conservation and Recovery Act (RCRA) multi-layered designs. The monitoring system deployed next to the U-3ax/bl disposal unit consists of eight drainage lysimeters with three surface treatments: two are left bare; two are revegetated with native species; two are being allowed to revegetate with invader species; and two are reserved for future studies. Soil used in each lysimeter is native alluvium taken from the same location as the soil used for the cover material on U-3ax/bl. The lysimeters were constructed so that any drainage to the bottom can be collected and measured. To provide a detailed evaluation of the cover performance, an ar ray of 16 sensors was installed in each lysimeter to measure soil water content, soil water potential, and soil temperature. Revegetation of the U-3ax/bl closure cover establishes a stable plant community that maximizes water loss through transpiration while at the same time, reduces water and wind erosion and ultimately restores the disposal unit to its surrounding Great Basin Desert environment

  13. Technology monitoring in the CIEMAT

    International Nuclear Information System (INIS)

    Perez-Martinez, M.; Cuesta, M. J.; Crespi, S. N.; Cabrera, J. A.

    2008-01-01

    The CIEMAT Foresight and Technology Monitoring Unit focuses its activities on obtaining strategic information on future developments in the area of energy and environment that can be used for decision making by the centers management. In addition, it provides services to CIEMAT researchers and other external customers. In May 2007, the Asociacion Espanola de Normalizacion y Certificacion AENOR delivered to the CIEMAT the first Technology Monitoring System certificate granted in Spain as per standard UNE 166006:2006. This article describes the Units experience in the implementation process of the Technology Monitoring System and provides several examples of the way in which the Unit graphically represents the information analyzed in its Technology Monitoring Reports. (Author)

  14. Smart textiles in neonatal monitoring : enabling unobtrusive monitoring at the NICU

    NARCIS (Netherlands)

    Seoane, F.; Bouwstra, S.; Marquez, J.; Löfhede, J.; Lindecrantz, K.; Chen, W.; Bambang Oetomo, S.; Feijs, L.M.G.

    2012-01-01

    Prematurely born and critically ill babies admitted to the Neonatal Intensive Care Unit require round-the-clock monitoring of vital signs and in special cases additional parameters such as brain functioning monitoring. Although close monitoring is fundamental for a good developmental outcome, the

  15. Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex

    NARCIS (Netherlands)

    Petoukhova, AL; Steenbergen, W; Morales, F; Graaff, R; de Jong, ED; Elstrodt, JM; de Mul, FFM; Rakhorst, G

    To investigate the feasibility of instrument-independent perfusion units for laser Doppler flowmetry, a comparison was performed of two commercial fiberoptic laser Doppler perfusion monitors measuring the same flux situation for two different types of probes. In vivo measurements were performed on

  16. Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex

    NARCIS (Netherlands)

    Petoukhova, Anna; Steenbergen, Wiendelt; Morales, F.; Graaff, R.; de Jong, Ed; Elstrodt, J.M.; de Mul, F.F.M.; Rakhorst, G.

    2003-01-01

    To investigate the feasibility of instrument-independent perfusion units for laser Doppler flowmetry, a comparison was performed of two commercial fiberoptic laser Doppler perfusion monitors measuring the same flux situation for two different types of probes. In vivo measurements were performed on

  17. Amikacin Dosing and Monitoring in Spinal Cord Injury Patients: Variation in Clinical Practice Between Spinal Injury Units and Differences in Experts' Recommendations

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2006-01-01

    Full Text Available The objective of this article was to determine the current practice on amikacin dosing and monitoring in spinal cord injury patients from spinal cord physicians and experts. Physicians from spinal units and clinical pharmacologists were asked to provide protocol for dosing and monitoring of amikacin therapy in spinal cord injury patients. In a spinal unit in Poland, amikacin is administered usually 0.5 g twice daily. A once-daily regimen of amikacin is never used and amikacin concentrations are not determined. In Belgium, Southport (U.K., Spain, and the VA McGuire Medical Center (Richmond, Virginia, amikacin is given once daily. Whereas peak and trough concentrations are determined in Belgium, only trough concentration is measured in Southport. In both these spinal units, modification of the dose is not routinely done with a nomogram. In Spain and the VA McGuire Medical Center, monitoring of serum amikacin concentration is not done unless a patient has renal impairment. In contrast, the dose/interval of amikacin is adjusted according to pharmacokinetic parameters at the Edward Hines VA Hospital (Hines, Illinois, where amikacin is administered q24h or q48h, depending on creatinine clearance. Spinal cord physicians from Denmark, Germany, and the Kessler Institute for Rehabilitation (West Orange, New Jersey state that they do not use amikacin in spinal injury patients. An expert from Canada does not recommend determining serum concentrations of amikacin, but emphasizes the value of monitoring ototoxicity and nephrotoxicity. Experts from New Zealand recommend amikacin in conventional twice- or thrice-daily dosing because of the theoretical increased risk of neuromuscular blockade and apnea with larger daily doses in spinal cord injury patients. On the contrary, experts from Greece, Israel, and the U.S. recommend once-daily dosing and determining amikacin pharmacokinetic parameters for each patient. As there is considerable variation in clinical

  18. Toxicological Evaluation of Essential Oil From the Leaves of Croton argyrophyllus (Euphorbiaceae) on Aedes aegypti (Diptera: Culicidae) and Mus musculus (Rodentia: Muridae).

    Science.gov (United States)

    Cruz, R C D; Silva, S L C E; Souza, I A; Gualberto, S A; Carvalho, K S; Santos, F R; Carvalho, M G

    2017-07-01

    Plant-derived essential oils can be used as insecticides for vector control. However, to establish their safety, it is necessary to perform toxicological studies. Herein, we evaluated the chemical composition and insecticidal activity of the essential oil from the leaves of Croton argyrophyllus on the third- and fourth-instar larvae and adult Aedes aegypti (L., 1762). We also evaluated the acute toxicity of the essential oil in adult female Mus musculus. The lethal concentration 50 (LC50) and 90 (LC90) of C. argyrophyllus essential oil on larvae of Ae. aegypti were 0.31 and 0.70 mg ml-1, respectively, and 5.92 and 8.94 mg ml-1, respectively, on Ae. aegypti adults. The major components of the essential oil were spathulenol (22.80%), (E)-caryophyllene (15.41%), α-pinene (14.07%), and bicyclogermacrene (10.43%). It also displayed acute toxicity in adults of Mus musculus; the intraperitoneal and oral lethal dose 50 (LD50) were 2,000 mg kg-1 and 2,500 mg kg-1, respectively. The results showed that the essential oil from C. argyrophyllus leaves has insecticidal activity on Ae. aegypti larvae and adults at an average lethal concentration below the median lethal dose needed to cause acute toxicity in the common mouse. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Treatment-Planning Study of Prostate Cancer Intensity-Modulated Radiotherapy With a Varian Clinac Operated Without a Flattening Filter

    International Nuclear Information System (INIS)

    Vassiliev, Oleg N.; Kry, Stephen F.; Kuban, Deborah A.; Salehpour, Mohammad; Mohan, Radhe; Titt, Uwe

    2007-01-01

    Purpose: To assess the feasibility of intensity-modulated radiotherapy for prostate cancer using photon beams from an accelerator operated without a flattening filter; and to determine potential benefits and drawbacks of using unflattened beams for this type of treatment. Methods and Materials: Intensity-modulated radiotherapy plans were generated for 10 patients with early-stage prostate cancer. For each patient, four plans were generated: with and without the flattening filter, at 6 and 18 MV. The prescription dose was 75.6 Gy to 98% of the planning target volume. The number of beams, their orientations, and optimization constraints were the same for all plans. Plans were generated with Eclipse 8.0 (Varian Medical Systems). Results: All the plans developed with unflattened beams were clinically acceptable. In terms of patient dose distributions, plans with unflattened beams were similar to the corresponding plans with flattened beams. Plans with unflattened beams required fewer monitor units (MUs) per plan: on average, by a factor of 2.0 at 6 MV and 2.6 at 18 MV, assuming that removal of the flattening filter was not followed by recalibration of MUs. Conclusions: Clinically acceptable intensity-modulated radiotherapy plans for prostate cancer can be developed with unflattened beams at both 6 and 18 MV. Dosimetrically, flattened and unflattened beams generated similar treatment plans. The plans with unflattened beams required substantially fewer MUs. The reduction in the number of MUs indicates corresponding reduction in beam-on time and in the amount of radiation outside the target

  20. Investment in epilepsy monitoring units improves epilepsy care—experience in a regional neuroscience centre

    LENUS (Irish Health Repository)

    McGinty, RN

    2017-08-01

    An evaluation of the clinical yield of inpatient long-term video-EEG (vEEG) in a new epilepsy monitoring unit (EMU) was undertaken, with findings compared to the centre’s prior method of bedside vEEG recording in a standard neurology ward, as reported in 2004. A retrospective analysis of neurophysiology reports for all adults who underwent elective vEEG monitoring in the EMU at Cork University Hospital between January 2015 and July 2016 was conducted. Of 115 vEEG studies in the EMU, 100 (87.0%) were deemed diagnostically conclusive, 14 (12.2%) failed to catch any clinical events and showed normal EEG throughout, and one (0.9%) captured spells of unclear clinical significance—the corresponding figures reported in 2004 for bedside vEEGs were 21.3%, 77% and 1.6%, respectively. The EMU offers a more effective method of recording inpatient vEEG, which aids decision-making and improves clinical outcomes. Some evidence-based measures which could further enhance diagnostic yield are discussed.

  1. Telephone audit for monitoring stroke unit facilities: a post hoc analysis from PROSIT study.

    Science.gov (United States)

    Candelise, Livia; Gattinoni, Monica; Bersano, Anna

    2015-01-01

    Although several valid approaches exist to measure the number and the quality of acute stroke units, only few studies tested their reliability. This study is aimed at establishing whether the telephone administration of the PROject of Stroke unIt ITaly (PROSIT) audit questionnaire is reliable compared with direct face-to-face interview. Forty-three medical leaders in charge of in-hospital stroke services were interviewed twice using the same PROSIT questionnaire with 2 different modalities. First, the interviewers approached the medical leaders by telephone. Thereafter, they went to the hospital site and performed a direct face-to-face interview. Six independent couples of trained researchers conducted the audit interviews. The degree of intermodality agreement was measured with kappa statistic. We found a perfect agreement for stroke units identification between the 2 different audit modalities (K = 1.00; standard error [SE], 1.525). The agreement was also very good for stroke dedicated beds (K = 1.00; SE, 1.525) and dedicated personnel (K = 1.00; SE, 1.525), which are the 2 components of stroke unit definition. The agreement was lower for declared in use process of care and availability of diagnostic investigations. The telephone audit can be used for monitoring stroke unit structures. It is more rapid, less expensive, and can repeatedly be used at appropriate intervals. However, a reliable description of the process of care and diagnostic investigations indicators should be obtained by either local site audit visit or prospective stroke register based on individual patient data. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  3. Fraksi Heksan dan Fraksi Metanol Ekstrak Biji Pepaya Muda Menghambat Spermatogonia Mencit (Mus Musculus Jantan

    Directory of Open Access Journals (Sweden)

    Bagus Komang Satriyasa

    2010-03-01

    Full Text Available To avoid population booming, family planning program should be maintained in which menand woman have the same rights and obligations. However in execution of family planning the roleof men is still low. Studies about contraception in men are limited. Male contraception that isknown in society are condom and vasectomy. In the recent few years in particular, researcheshave been refocused on investigating traditional plants as anti fertility. In use researches manyplants have been studied, including papaya seed. Some researches on herbal anti fertility propertiesof papaya seed have been carried out including those on the active compounds of anti fertility, onapprolaki-lakite dosage of extract of carica papaya seed by animal experiments. Hexane fraction ofunripe papaya seed extract contains glycosides, alkaloid and triterpenoids, which is assumed hasan antifertility effect, so it can be used as a male contraceptive, although the mechanism of actionis not yet clear. Research is conducted at Animal Laboratory Unit Department of PharmacologyFaculty of Medicine University of Udayana, and Laboratorium Patologi Balai Penyidikan danPengujian Veterian (BPPV Wilayah VI Denpasar Direktorat Jenderal Peternakan, DepartmentPertanian. This study used the pre-test and post-test control group design, using 30 male mice ofbalb C strain, aged 12 weeks, weight 20-22 gram, subsequently grouped by random into 3 groupseach consisting of 10 male mice. One control group (P0 = control group was given double distilledwater, and two treatment groups (P1 = treatment group was given fraction of the hexane extractof young Carica papaya seed 20 mg/20gram Body wieght/day, (P2 = treatment group was givenfraction of the methanol extract of young Carica papaya seed 20 mg/20 gram/day. After 36 days oftreatment, evaluation of the testis, of the male mice was conducted. Data were analysed by normalitytest of Shapiro-will, homogeneity test, and Anova test. This study showed that cells of

  4. La Morue Normande, de la conserverie au musée

    Directory of Open Access Journals (Sweden)

    Florence Levert

    2007-03-01

    Full Text Available L’usine de La Morue Normande de Fécamp est mise en service en 1950. Initialement pensée pour sécher la morue débarquée par centaines de tonnes, elle connaîtra jusqu’à sa fermeture en 1995, une large diversification. Les adaptations successives seront facilitées par la souplesse de la structure poteaux-poutres. La multiplicité des expériences qui s’y sont déroulées paraît aujourd’hui symptomatique du déclin de la pêche industrielle fécampoise. Alors qu’à l’heure actuelle coexistent une industrie de transformation qui a quitté la zone portuaire et une pêche côtière n’entretenant plus aucun lien, l’immeuble désaffecté de La Morue Normande abritera bientôt le nouveau musée de Fécamp.In Fécamp, the factory of La Morue Normande opened in 1950. Initially created to dry cods brought by hundreds of tons, it will undergo many changes until its closing. Thank to its post-beam structure, an easy adaptation is provided. This diversification seems to be symptomatic of the decline of Fécamp industrial fishing. Nowadays, while a processing industry which left the port area a few years ago and the coastal fishing do not relate to each other anymore, the building of La Morue Normande will be soon the location of the new museum of Fécamp.

  5. Nesting behavior of house mice (Mus domesticus) selected for increased wheel-running activity.

    Science.gov (United States)

    Carter, P A; Swallow, J G; Davis, S J; Garland, T

    2000-03-01

    Nest building was measured in "active" (housed with access to running wheels) and "sedentary" (without wheel access) mice (Mus domesticus) from four replicate lines selected for 10 generations for high voluntary wheel-running behavior, and from four randombred control lines. Based on previous studies of mice bidirectionally selected for thermoregulatory nest building, it was hypothesized that nest building would show a negative correlated response to selection on wheel-running. Such a response could constrain the evolution of high voluntary activity because nesting has also been shown to be positively genetically correlated with successful production of weaned pups. With wheel access, selected mice of both sexes built significantly smaller nests than did control mice. Without wheel access, selected females also built significantly smaller nests than did control females, but only when body mass was excluded from the statistical model, suggesting that body mass mediated this correlated response to selection. Total distance run and mean running speed on wheels was significantly higher in selected mice than in controls, but no differences in amount of time spent running were measured, indicating a complex cause of the response of nesting to selection for voluntary wheel running.

  6. A practical approach for electron monitor unit calculation

    International Nuclear Information System (INIS)

    Choi, David; Patyal, Baldev; Cho, Jongmin; Cheng, Ing Y; Nookala, Prashanth

    2009-01-01

    Electron monitor unit (MU) calculation requires measured beam data such as the relative output factor (ROF) of a cone, insert correction factor (ICF) and effective source-to-surface distance (ESD). Measuring the beam data to cover all possible clinical cases is not practical for a busy clinic because it takes tremendous time and labor. In this study, we propose a practical approach to reduce the number of data measurements without affecting accuracy. It is based on two findings of dosimetric properties of electron beams. One is that the output ratio of two inserts is independent of the cone used, and the other is that ESD is a function of field size but independent of cone and jaw opening. For the measurements to prove the findings, a parallel plate ion chamber (Markus, PTW 23343) with an electrometer (Cardinal Health 35040) was used. We measured the outputs to determine ROF, ICF and ESD of different energies (5-21 MeV). Measurements were made in a Plastic Water(TM) phantom or in water. Three linear accelerators were used: Siemens MD2 (S/N 2689), Siemens Primus (S/N 3305) and Varian Clinic 21-EX (S/N 1495). With these findings, the number of data set to be measured can be reduced to less than 20% of the data points. (note)

  7. Evaluation of clinically applied treatment beams with respect to bunker shielding parameters for a Cyberknife M6.

    Science.gov (United States)

    Henzen, Dominik; Schmidhalter, Daniel; Zanella, Claudia Christina; Volken, Werner; Mackeprang, Paul-Henry; Malthaner, Marco; Fix, Michael Karl; Manser, Peter

    2018-01-01

    Compared to a conventional linear accelerator, the Cyberknife (CK) is a unique system with respect to radiation protection shielding and the variety and number of non-coplanar beams are two key components regarding this aspect. In this work, a framework to assess the direction distribution and modulation factor (MF) of clinically applied treatment beams of a CyberKnife M6 is developed. Database filtering options allow studying the influence of different parameters such as collimator types, treatment sites or different bunker sizes. A distribution of monitor units (MU) is generated by projecting treatment beams onto the walls, floor and ceiling of the CyberKnife bunker. This distribution is found to be highly heterogeneous and depending, among other parameters, on the bunker size. For our bunker design, 10%-13% of the MUs are delivered to the right and left wall, each. The floor receives more than 64% of the applied MUs, while the wall behind the patient's head is not hit by primary treatment beams. Between 0% and 5% of the total MUs are delivered to the wall at the patient's feet. This number highly depends on the treatment site, e.g., for extracranial patients no beams hit that wall. Collimator choice was found to have minor influence on the distribution of MUs. On the other hand, the MF depends on the collimator type as well as on the treatment site. The MFs (delivered MU/prescribed dose) for all treatments, all MLC treatments, cranial and extracranial treatments are 8.3, 6.4, 7.7, and 9.9 MU/cGy, respectively. The developed framework allows assessing and monitoring important parameters regarding radiation protection of a CK-M6 using the actually applied treatment beams. Furthermore, it enables evaluating different clinical and constructional situations using the filtering options. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. Diseño de una compañía exportadora de banano y otras musáceas para el mercado ruso

    OpenAIRE

    Játiva Murillo, Henry Isaac

    2013-01-01

    El proyecto tiene la finalidad de mostrar los aspectos legales, estratégicos y comerciales para la exportación de banano al mercado ruso, aprovechando la demanda creciente del país y la gran riqueza de producción de la fruta en el Ecuador. También se analizará agregar otros productos musáceos al mismo mercado ruso, aprovechando las operaciones logísticas y comerciales que la nueva empresa tendrá en el país europeo. Se determinará el nombre de la empresa, los aspectos legales, el capi...

  9. Automated system of monitoring and positioning of functional units of mining technological machines for coal-mining enterprises

    Directory of Open Access Journals (Sweden)

    Meshcheryakov Yaroslav

    2018-01-01

    Full Text Available This article is show to the development of an automated monitoring and positioning system for functional nodes of mining technological machines. It describes the structure, element base, algorithms for identifying the operating states of a walking excavator; various types of errors in the functioning of microelectromechanical gyroscopes and accelerometers, as well as methods for their correction based on the Madgwick fusion filter. The results of industrial tests of an automated monitoring and positioning system for functional units on one of the opencast coal mines of Kuzbass are presented. This work is addressed to specialists working in the fields of the development of embedded systems and control systems, radio electronics, mechatronics, and robotics.

  10. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  11. Sexual selection and the rodent baculum: an intraspecific study in the house mouse (Mus musculus domesticus).

    Science.gov (United States)

    Ramm, Steven A; Khoo, Lin; Stockley, Paula

    2010-01-01

    The rapid divergence of genitalia is a pervasive trend in animal evolution, thought to be due to the action of sexual selection. To test predictions from the sexual selection hypothesis, we here report data on the allometry, variation, plasticity and condition dependence of baculum morphology in the house mouse (Mus musculus domesticus). We find that that baculum size: (a) exhibits no consistent pattern of allometric scaling (baculum size being in most cases unrelated to body size), (b) exhibits low to moderate levels of phenotypic variation, (c) does not exhibit phenotypic plasticity in response to differences in perceived levels of sexual competition and (d) exhibits limited evidence of condition dependence. These patterns provide only limited evidence in support of the sexual selection hypothesis, and no consistent support for any particular sexual selection mechanism; however, more direct measures of how genital morphology influences male fertilization success are required.

  12. Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery

    International Nuclear Information System (INIS)

    Li Kaile; Dai Jianrong; Ma Lijun

    2004-01-01

    Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment between segments. We implemented and demonstrated our method for multiple clinical cases. We compared the results of our method with the results from exhaustive search method. We found that our solution without leaf end abutment produced equivalent results to the unconstrained solutions in terms of minimum total monitor units and minimum number of leaf segments. We conclude that the leaf end abutment fields can be avoided without affecting the efficiency of segmental IMRT delivery. The major strength of our method is its simplicity and high computing speed. This potentially provides a useful means for generating segmental IMRT fields that require high spatial resolution or complex intensity distributions

  13. Performance of risk-adjusted control charts to monitor in-hospital mortality of intensive care unit patients: A simulation study

    NARCIS (Netherlands)

    Koetsier, Antonie; de Keizer, Nicolette F.; de Jonge, Evert; Cook, David A.; Peek, Niels

    2012-01-01

    Objectives: Increases in case-mix adjusted mortality may be indications of decreasing quality of care. Risk-adjusted control charts can be used for in-hospital mortality monitoring in intensive care units by issuing a warning signal when there are more deaths than expected. The aim of this study was

  14. Monitoring eradication of European mouflon sheep from the Kahuku Unit of Hawai‘i Volcanoes National Park

    Science.gov (United States)

    Judge, Seth; Hess, Steven C.; Faford, Jonathan K.; Pacheco, Dexter; Leopold, Christina

    2017-01-01

    European mouflon (Ovis gmelini musimon), the world's smallest wild sheep, have proliferated and degraded fragile native ecosystems in the Hawaiian Islands through browsing, bark stripping, and trampling, including native forests within Hawai‘i Volcanoes National Park (HAVO). HAVO resource managers initiated ungulate control efforts in the 469 km2 Kahuku Unit after it was acquired in 2003. We tracked control effort and used aerial surveys in a 64.7 km2 area from 2004 to 2017 and more intensive ground surveys and camera-trap monitoring to detect the last remaining animals within a 25.9 km2 subunit after it was enclosed by fence in 2012. Aerial shooting yielded the most removals per unit effort (3.2 animals/ hour), resulting in 261 animals. However, ground-based methods yielded 4,607 removals overall, 3,038 of which resulted from assistance of volunteers. Ground shooting with dogs, intensive aerial shooting, ground sweeps, and forward-looking infrared (FLIR)-assisted shooting were necessary to find and remove the last remaining mouflon. The Judas technique, baiting, and trapping were not successful in attracting or detecting small numbers of remaining individuals. Effort expended to remove each mouflon increased nearly 15-fold during the last 3 yr of eradication effort from 2013 to 2016. Complementary active and passive monitoring techniques allowed us to track the effectiveness of control effort and reveal locations of small groups to staff. The effort and variety of methods required to eradicate mouflon from an enclosed unit of moderate size illustrates the difficulty of scaling up to entire populations of wild ungulates from unenclosed areas.

  15. An enhanced ionising radiation monitoring and detecting technique in radiotherapy units of hospitals using wireless sensor networks

    International Nuclear Information System (INIS)

    Ali, Peter

    2017-01-01

    In this paper, a solution of ionising radiation monitoring based on the concept of Wireless Sensor Network (WSN), is presented. Radiation dose rate measured by the sensor node is sent to the monitoring station through ZigBee wireless network operated on 2.4 GHz unlicensed Industrial Scientific Medical (ISM) band. The system is calibrated for use for ionizing radiation dose rate range of between amount of ionising radiation observed in radiotherapy unit of a hospital and 1.02 mSv/h. Power consumption of the sensor node is kept low by operating the node ZigBee radio with low duty cycle: i.e. by keeping the radio awake only during data transmission/reception. Two ATmega8 microcontrollers, one each for sensor node and the monitoring station, are programmed to perform interfacing, data processing, and control functions. The system range of coverage is 124m for outdoor (line of site) deployment and 56.8m for indoor application where 5 brick walls separated the sensor node and the monitoring station. Range of coverage of the system is extendable via the use of ZigBee router (s)

  16. Simplified conversions between specific conductance and salinity units for use with data from monitoring stations

    Science.gov (United States)

    Schemel, Laurence E.

    2001-01-01

    The U.S. Geological Survey, Bureau of Reclamation, and the California Department of Water Resources maintain a large number of monitoring stations that record specific conductance, often referred to as “electrical conductivity,” in San Francisco Bay Estuary and the Sacramento-San Joaquin Delta. Specific conductance units that have been normalized to a standard temperature are useful in fresh waters, but conversion to salinity units has some considerable advantages in brackish waters of the estuary and Delta. For example, salinity is linearly related to the mixing ratio of freshwater and seawater, which is not the case for specific conductance, even when values are normalized to a standard temperature. The Practical Salinity Scale 1978 is based on specific conductance, temperature, and pressure measurements of seawater and freshwater mixtures (Lewis 1980 and references therein). Equations and data that define the scale make possible conversions between specific conductance and salinity values.

  17. THE PATTERN OF THE AGGRESSIVE BEHAVIOR IN THE LABORATORY MOUSE (MUS MUSCULUS

    Directory of Open Access Journals (Sweden)

    Maria BUNEA

    2010-01-01

    Full Text Available Nature has found solutions for decreasing the aggressive impulse, using various inhibitory mechanisms as means of balancing the forces between two fighting individuals, thus avoiding it to lead to the destruction of their own species. These nature's “ pacifyng” solutions are mostly found in animals which are armed with various potentially lethal “weapons”, while in species that live on large territoires and thus have the possibility to avoid conflict, these mechanisms are poorly developed. The purpose of this research is to study the extent of the inhibitory mechanisms against aggression in the laboratory mouse, species in which these mechanisms of diminishing aggression and of avoiding conflicts don't work the same in artificial conditions, where individuals are forced to live in small areas, and to identify the behavioral chains that form the innate manifestations of the aggressive behavior in Mus musculus sp. The results of this study show that in the circumstance of caged individuals, which are crowded so closely together, the intensity of aggression is increasing. The dominance hierarchy is well established after their first fight, but due to the spatial constraint and the fact that there is no place where to flee, the submissive individual oftenly fights back. In every single interraction the aggressive behavior follows a fixed action pattern.

  18. Applications of the monitor of loose parts in the cycle 6 of the Laguna Verde Unit 2 power plant; Aplicaciones del monitor de partes sueltas en el ciclo 6 de la Unidad 2 de la central Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Calleros, G.; Mendez, A.; Gomez, R.A. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Veracruz (Mexico); Castillo, R.; Bravo, J.M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: gcm9acpp@cfe.gob.mx

    2004-07-01

    The monitor of loose parts (Loose Parts Monitoring System) installed in the Unit 2 of the Laguna Verde Central is a tool to detect strange objects or parts loose in the system of refrigeration of the reactor that could be impacted in the walls of the recirculation knots or in the internal of the reactor. In this work two applications are shown carried out with the Monitor of Loose Parts, determining the characteristics of the stable nominal conditions, those which when changing, they are used to diagnose during the Cycle 6 of the Unit 2, failures in the components of the the recirculation circuits or to identify mechanical vibrations of the recirculation knots induced by a flow of recirculation bistable associated to operative conditions of the reactor. (Author)

  19. Validation of a new software version for monitoring of the core of the Unit 2 of the Laguna Verde power plant with ARTS

    International Nuclear Information System (INIS)

    Calleros, G.; Riestra, M.; Ibanez, C.; Lopez, X.; Vargas, A.; Mendez, A.; Gomez, R.

    2005-01-01

    In this work it is intended a methodology to validate a new version of the software used for monitoring the reactor core, which requires of the evaluation of the thermal limits settled down in the Operation Technical Specifications, for the Unit 2 of Laguna Verde with ARTS (improvements to the APRMs, Rod Block Monitor and Technical specifications). According to the proposed methodology, those are shown differences found in the thermal limits determined with the new versions and previous of the core monitoring software. Author)

  20. Microphone variability and degradation: implications for monitoring programs employing autonomous recording units

    Directory of Open Access Journals (Sweden)

    Patrick J. Turgeon

    2017-06-01

    Full Text Available Autonomous recording units (ARUs are emerging as an effective tool for avian population monitoring and research. Although ARU technology is being rapidly adopted, there is a need to establish whether variation in ARU components and their degradation with use might introduce detection biases that would affect long-term monitoring and research projects. We assessed whether microphone sensitivity impacted the probability of detecting bird vocalizations by broadcasting a sequence of 12 calls toward an array of commercially available ARUs equipped with microphones of varying sensitivities under three levels (32 dBA, 42 dBA, and 50 dBA of experimentally induced noise conditions selected to reflect the range of noise levels commonly encountered during avian surveys. We used binomial regression to examine factors influencing probability of detection for each species and used these to examine the impact of microphone sensitivity on the effective detection area (ha for each species. Microphone sensitivity loss reduced detection probability for all species examined, but the magnitude of the effect varied between species and often interacted with distance. Microphone sensitivity loss reduced the effective detection area by an average of 25% for microphones just beyond manufacturer specifications (-5 dBV and by an average of 66% for severely compromised microphones (-20 dBV. Microphone sensitivity loss appeared to be more problematic for low frequency calls where reduction in the effective detection area occurred most rapidly. Microphone degradation poses a source of variation in avian surveys made with ARUs that will require regular measurement of microphone sensitivity and criteria for microphone replacement to ensure scientifically reproducible results. We recommend that research and monitoring projects employing ARUs test their microphones regularly, replace microphones with declining sensitivity, and record sensitivity as a potential covariate in

  1. FBH1 co-operates with MUS81 in inducing DNA double-strand breaks and cell death following replication stress

    DEFF Research Database (Denmark)

    Fugger, Kasper; Chu, Wai Kit; Haahr, Peter

    2013-01-01

    The molecular events occurring following the disruption of DNA replication forks are poorly characterized, despite extensive use of replication inhibitors such as hydroxyurea in the treatment of malignancies. Here, we identify a key role for the FBH1 helicase in mediating DNA double-strand break...... formation following replication inhibition. We show that FBH1-deficient cells are resistant to killing by hydroxyurea, and exhibit impaired activation of the pro-apoptotic factor p53, consistent with decreased DNA double-strand break formation. Similar findings were obtained in murine ES cells carrying...... of replication stress. Our data suggest that FBH1 helicase activity is required to eliminate cells with excessive replication stress through the generation of MUS81-induced DNA double-strand breaks....

  2. Experience of our new monitor for betatron therapy unit

    International Nuclear Information System (INIS)

    Kanno, Takenori; Sato, Hisao; Abe, Shunsuke; Suyama, Sachio.

    1975-01-01

    The amount of high energy electron beams is instable owing to lots of factors. As a matter of course, we should be careful in controling the amount of beams and it is also necessary to improve the beam monitoring apparatuses to make them stable. We have improved a usual monitor and had experiments with it. Here is the report. (1) An ordinary monitor is influenced by humidity, air atmosphere induced noise from an apparatus and so on. We made a new monitor with due regard to these factors. When the count is set to 100 with a usual monitor, the standard dose meter (ionex) indicate is 280 R in 16 MeV and the lowest one is 198 R. Between standard dose meter (ionex) and usual monitor is 82 R. With the trial monitor, the highest integrated dose is 103 R and the lowest one is 89 R. The difference is only 14 R and we are satisfied with the result. We gain this value after 16 months' trial. (2) The chamber is made air tight and has a double structure with a collection electrode sandwiched between high tension charging electrodes. In this way, we can eliminate the influences of humidity and induced noise from an apparatus itself and we can putup ion collection efficiency without widening the distance between the electrodes. As for the indicator circuit, we can get an input signal with a big s/n ratio and so we need not use high impedance resistors in the input circuitry. There is little affect from humidity and induced noise, and the circuit is stable. The indicator circuit has a complete electronic system, therefore counting speed is greatly improved and we can measure a large amount of beams in a short time. The trial monitor has four measuring ranges and so measuring is easily done. Our monitor has a circuit tester, too, and we can test the measuring circuit on occasion. (auth.)

  3. STRUKTUR HISTOLOGI HATI MENCIT(Mus musculus L. SETELAH PEMBERIAN EKSTRAK DAUN EKOR NAGA (Rhapidhophora pinnata Schott

    Directory of Open Access Journals (Sweden)

    Ni Komang Tia Pramesti

    2017-09-01

    Full Text Available ABSTRACT Rhapidhophora pinnata, Schott is a traditional medical plant that has been use remedy for treatment of hypertension, stroke. Aims of  this research is to determine the effect of Rhapidhophora pinnata Schott leaf extract toward  mouse (Mus musculus L liverhistological structure. This research used completely randomized  design with 28 female mice that were divide into 4 groups of  P0 (control received 0,9% NaCl, group P1, P2, and P3 received 50, 100 and 150 mg/kg bw respectively by oral administration. The treatment were given daily for 14 days. All of the mice were sacrificed by ether after 15 days. The liver were examined for their histopathological changes, namely fatty degeneration, hydropic degenaration and necrosis. Results were statistically analised by Kruskal-Wallis method. Treatment groups showed no significant differences with regard of liver histopatological changes, however hemorrhage, sinusoid congestion and inflamatory cell infiltration were found in liver.   Keyword : Rhapidhophora pinnata Schott, liver, mice

  4. Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Elena Bergon-Sendin

    2015-01-01

    Full Text Available Background. Random safety audits (RSAs are a safety tool but have not been widely used in hospitals. Objectives. To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods. A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device. Results. A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12–3.06, p=0.01, and during the late shift (3 pm to 10 pm, OR 1.59 (1.03–2.4, p=0.03. Conclusions. Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.

  5. Habitat use and demography of Mus musculus in a rural landscape of Argentina.

    Science.gov (United States)

    León, Vanina A; Fraschina, Jimena; Guidobono, Juan S; Busch, Maria

    2013-04-01

    The main goal of the paper was to determine the habitat distribution of the house mouse (Mus musculus) within a rural landscape of Buenos Aires province, Argentina. We also studied the seasonal variation in abundance and reproductive activity. The habitats studied were poultry farms, human houses in a small village, cropfields, pastures, cropfield and pasture edges, riparian habitats (streams), railway embankments and woodlots. We captured 817 M. musculus and 690 individuals of 5 native rodent species. M. musculus was captured in poultry farms, houses, riparian habitats, cropfield and borders, but it showed a significantly higher abundance in poultry farms compared to the other habitats. Its presence outside poultry farms was significantly related to the distance to streams and poultry farms. The mean trapping success index of M. musculus did not show significant variations between periods, but the proportion of active males was significantly higher in the spring-summer period than in the autumn-winter period. All captures of M. musculus in cropfields, borders and riparian habitats occurred in the spring-summer period. The capture of M. musculus in many types of habitats suggests that it can disperse outside poultry farms, and streams may be used as corridors. © 2012 Wiley Publishing Asia Pty Ltd, ISZS and IOZ/CAS.

  6. Chromosomal heterozygosity and fertility in house mice (Mus musculus domesticus) from Northern Italy.

    Science.gov (United States)

    Hauffe, H C; Searle, J B

    1998-11-01

    Following the discovery of over 40 Robertsonian (Rb) races of Mus musculus domesticus in Europe and North Africa, the house mouse has been studied extensively as an ideal model to determine the chromosomal changes that may cause or accompany speciation. Current models of chromosomal speciation are based on the assumption that heterozygous individuals have a particularly low fertility, although recent studies indicate otherwise. Despite their importance, fertility estimates for the house mouse are incomplete because traditional measurements, such as anaphase I nondisjunction and germ cell death, are rarely estimated in conjunction with litter size. In an attempt to bridge this gap, we have taken advantage of the house mouse hybrid zone in Upper Valtellina (Lombardy, Italy) in which five Rb races interbreed. We present data on the fertility of naturally occurring ("wild-caught") hybrids and of offspring from laboratory crosses of wild-caught mice ("laboratory-reared"), using various measurements. Wild-caught mice heterozygous for one fusion were more infertile than predicted from past studies, possibly due to genic hybridity; laboratory-reared heterozygotes carrying seven or eight trivalents at meiosis I and heterozygotes carrying one pentavalent also had low fertilities. These low fertilities are especially significant given the probable occurrence of a reinforcement event in Upper Valtellina.

  7. The French Muséum national d'histoire naturelle vascular plant herbarium collection dataset

    Science.gov (United States)

    Le Bras, Gwenaël; Pignal, Marc; Jeanson, Marc L.; Muller, Serge; Aupic, Cécile; Carré, Benoît; Flament, Grégoire; Gaudeul, Myriam; Gonçalves, Claudia; Invernón, Vanessa R.; Jabbour, Florian; Lerat, Elodie; Lowry, Porter P.; Offroy, Bérangère; Pimparé, Eva Pérez; Poncy, Odile; Rouhan, Germinal; Haevermans, Thomas

    2017-02-01

    We provide a quantitative description of the French national herbarium vascular plants collection dataset. Held at the Muséum national d'histoire naturelle, Paris, it currently comprises records for 5,400,000 specimens, representing 90% of the estimated total of specimens. Ninety nine percent of the specimen entries are linked to one or more images and 16% have field-collecting information available. This major botanical collection represents the results of over three centuries of exploration and study. The sources of the collection are global, with a strong representation for France, including overseas territories, and former French colonies. The compilation of this dataset was made possible through numerous national and international projects, the most important of which was linked to the renovation of the herbarium building. The vascular plant collection is actively expanding today, hence the continuous growth exhibited by the dataset, which can be fully accessed through the GBIF portal or the MNHN database portal (available at: https://science.mnhn.fr/institution/mnhn/collection/p/item/search/form). This dataset is a major source of data for systematics, global plants macroecological studies or conservation assessments.

  8. The French Muséum national d’histoire naturelle vascular plant herbarium collection dataset

    Science.gov (United States)

    Le Bras, Gwenaël; Pignal, Marc; Jeanson, Marc L.; Muller, Serge; Aupic, Cécile; Carré, Benoît; Flament, Grégoire; Gaudeul, Myriam; Gonçalves, Claudia; Invernón, Vanessa R.; Jabbour, Florian; Lerat, Elodie; Lowry, Porter P.; Offroy, Bérangère; Pimparé, Eva Pérez; Poncy, Odile; Rouhan, Germinal; Haevermans, Thomas

    2017-01-01

    We provide a quantitative description of the French national herbarium vascular plants collection dataset. Held at the Muséum national d’histoire naturelle, Paris, it currently comprises records for 5,400,000 specimens, representing 90% of the estimated total of specimens. Ninety nine percent of the specimen entries are linked to one or more images and 16% have field-collecting information available. This major botanical collection represents the results of over three centuries of exploration and study. The sources of the collection are global, with a strong representation for France, including overseas territories, and former French colonies. The compilation of this dataset was made possible through numerous national and international projects, the most important of which was linked to the renovation of the herbarium building. The vascular plant collection is actively expanding today, hence the continuous growth exhibited by the dataset, which can be fully accessed through the GBIF portal or the MNHN database portal (available at: https://science.mnhn.fr/institution/mnhn/collection/p/item/search/form). This dataset is a major source of data for systematics, global plants macroecological studies or conservation assessments. PMID:28195585

  9. Penelitian Pendahuluan Pengaruh Daun Manggis sebagai Rodentisida Nabati pada Mencit Mus musculus Strain Balepsi

    Directory of Open Access Journals (Sweden)

    Agus Kardinan

    2000-07-01

    Full Text Available Research has been conducted at Pest and Disease Laboratory, Research Institute for Spices and Medicinal Crops, Bogor, during 1997-1998. The objective was to evaluate the possibility of Mangosteen (Garcinia mangostana leaves to be used as botanical rodenticide which is tested to reproduction ability of mice Mus musculus. Eight to ten weeks old mice with the average weight of 25 gram were obtained from Research Institute for Livestock, Ciawi. Research was arranged at randomized block design, 8 treatments and 4 replications. Data was analyzed by determining the average value and their standard deviation values. Observations were done to the weight of testis, weight of embryo, number of embryo, volume of extracts drank by mice and mice behavior during experiment. Result revealed that there was no indication that the leaves extract affected the weight of testis, but it affected the number and weight of embryo. There was indication that mangosteen leaves acted as antifertility on mice. Giving leaves extract increased the total volume of extract drink. There was no abnormality at the activity of mice during experiment, included sex activity, poisonous symptoms and others.

  10. Design of an Integrated Sensor Platform for Vital Sign Monitoring of Newborn Infants at Neonatal Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2010-01-01

    Full Text Available Continuous health status monitoring and advances in medical treatments have resulted in a significant increase of survival rate in critically ill infants admitted into Neonatal Intensive Care Units (NICUs. The quality of life and long-term health prospects of the neonates depend increasingly on the reliability and comfort of the monitoring systems. In this paper, we present the design work of a smart jacket for vital sign monitoring of neonates at a NICU. The design represents a unique integration of sensor technology, user focus and design aspects. Textile sensors, a reflectance pulse oximeter and a wearable temperature sensor were proposed to be embedded into the smart jacket. Location of the sensor, materials and appearance were designed to optimize the functionality, patient comfort and the possibilities for aesthetic features. Prototypes were built for demonstrating the design concept and experimental results were obtained from tests on premature babies at the NICU of M�xima Medical Centre (MMC in Veldhoven, the Netherlands.

  11. Seven harmonic susceptibility in oxygen and hydrogen loading of sintered YBCO by {mu}s pulsed electrolysis in an aqueous solution at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Tripodi, P.; Di Gioacchino, D.; Celani, F. [Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati

    1996-09-01

    The complex AC susceptibility of high T{sub c} superconducting materials has been described in terms of the first seven harmonic component of Fourier series. Has been measured the {chi}{sub n} (n=1,7) of sintered YBa{sub 2}Cu{sub 3}O{sub 7-x} (YBCO) bulk oxygen and hydrogen loaded samples versus amplitude and frequency of AC magnetic field at fixed temperature. The sample have been loaded by {mu}s current pulses electrolysis in an aqueous solution (0.3N LiOH+H{sub 2}O) at room temperature. In addition to the simplicity of the experimental setup, this procedure allows to obtain extremely high equivalent hydrogen/oxygen gas pressure on the surface of the electrodes. The YBCO electrode is polarized by short pulse width (0.5-10 {mu}s) and high power (120 W) peaks with a variable repetition rate (0.1-10000 Hz). The pulses are obtained by an home.made pulse generator. The difference in the behavior of the susceptibilities harmonic component between the deficiency and oxygen or hydrogen loaded samples give us the possibility to connect the susceptibilities with variations of the flux pinning in respect to normal losses in the superconducting materials. The loading can be a good probe to have information on the mechanism of the processes that sustain the critical current density Jc in this situation these affects appear strongly dependent on the loading conditions. By comparison of this measurements has been observed drastic change in behavior of susceptibility.

  12. Monitor tables for electron beams in radiotherapy

    International Nuclear Information System (INIS)

    Christ, G.; Dohm, O.S.

    2007-01-01

    The application of electron beams in radiotherapy is still based on tables of monitor units, although 3-D treatment planning systems for electron beams are available. This have several reasons: The need for 3-D treatment planning is not recognized; there is no confidence in the calculation algorithm; Monte-Carlo algorithms are too time-consuming; and the effort necessary to measure basic beam data for 3-D planning is considered disproportionate. However, the increasing clinical need for higher dosimetric precision and for more conformal electron beams leads to the requirement for more sophisticated tables of monitor units. The present paper summarizes and discusses the main aspects concerning the preparation of tables of monitor units for electron beams. The measurement equipment and procedures for measuring basic beam data needed for tables of monitor units for electron beams are described for a standard radiation therapy linac. The design of tables of monitor units for standard electron applicators is presented; this design can be extended for individual electron inserts, to variable applicator surface distances, to oblique beam incidence, and the use of bolus material. Typical data of an Elekta linac are presented in various tables. (orig.)

  13. Development of an on-line radon monitoring apparatus and design of the on-line radon monitoring platform based on CAN bus

    International Nuclear Information System (INIS)

    Guo Huiping; Lu Ning; Shang Aiguo; Zhou Chunlin; Chen Yingfen; Yu Hongwei

    2004-12-01

    For actual demand, an idea of 'on-line monitoring' is put forward as a way of radon monitoring, instead of traditional so called 'off-line monitoring'. In this way, the apparatus has some automatic functions such as continuous monitoring, real-time alarm; thereby, there is no need for operators' intervention in each monitoring process. With technique of hardware and software design in automation's field, the authors have successfully developed the prototype and finished the scale of it in a standard radon-chamber. This apparatus is composed of detector part and secondary-instrument. The detector part is made up of a passive diffusion collecting chamber, high voltage static electricity, semiconductor detector, charge-sensitive preamplifier and forming circuit. The secondary-instrument is actually a micro-controller system, which consists of a single-chip micro-controller cored measure-controlling unit, display unit, printing unit and alarming unit. Taking this apparatus as a cell, a 'on-line Radon Monitoring Platform' based on CAN bus has been put forward, which can realize multi-points environmental radioactivity real-time monitoring radioactivity and data process. (authors)

  14. Two genetic determinants acquired late in Mus evolution regulate the inclusion of exon 5, which alters mouse APOBEC3 translation efficiency.

    Directory of Open Access Journals (Sweden)

    Jun Li

    2012-01-01

    Full Text Available Mouse apolipoprotein B mRNA-editing enzyme catalytic polypeptide-like editing complex 3 (mA3, an intracellular antiviral factor, has 2 allelic variations that are linked with different susceptibilities to beta- and gammaretrovirus infections among various mouse strains. In virus-resistant C57BL/6 (B6 mice, mA3 transcripts are more abundant than those in susceptible BALB/c mice both in the spleen and bone marrow. These strains of mice also express mA3 transcripts with different splicing patterns: B6 mice preferentially express exon 5-deficient (Δ5 mA3 mRNA, while BALB/c mice produce exon 5-containing full-length mA3 mRNA as the major transcript. Although the protein product of the Δ5 mRNA exerts stronger antiretroviral activities than the full-length protein, how exon 5 affects mA3 antiviral activity, as well as the genetic mechanisms regulating exon 5 inclusion into the mA3 transcripts, remains largely uncharacterized. Here we show that mA3 exon 5 is indeed a functional element that influences protein synthesis at a post-transcriptional level. We further employed in vitro splicing assays using genomic DNA clones to identify two critical polymorphisms affecting the inclusion of exon 5 into mA3 transcripts: the number of TCCT repeats upstream of exon 5 and the single nucleotide polymorphism within exon 5 located 12 bases upstream of the exon 5/intron 5 boundary. Distribution of the above polymorphisms among different Mus species indicates that the inclusion of exon 5 into mA3 mRNA is a relatively recent event in the evolution of mice. The widespread geographic distribution of this exon 5-including genetic variant suggests that in some Mus populations the cost of maintaining an effective but mutagenic enzyme may outweigh its antiviral function.

  15. Effects of organ motion on IMRT treatments with segments of few monitor units

    International Nuclear Information System (INIS)

    Seco, J.; Sharp, G. C.; Turcotte, J.; Gierga, D.; Bortfeld, T.; Paganetti, H.

    2007-01-01

    Interplay between organ (breathing) motion and leaf motion has been shown in the literature to have a small dosimetric impact for clinical conditions (over a 30 fraction treatment). However, previous studies did not consider the case of treatment beams made up of many few-monitor-unit (MU) segments, where the segment delivery time (1-2 s) is of the order of the breathing period (3-5 s). In this study we assess if breathing compromises the radiotherapy treatment with IMRT segments of low number of MUs. We assess (i) how delivered dose varies, from patient to patient, with the number of MU per segment, (ii) if this delivered dose is identical to the average dose calculated without motion over the path of the motion, and (iii) the impact of the daily variation of the delivered dose as a function of MU per segment. The organ motion was studied along two orthogonal directions, representing the left-right and cranial-caudal directions of organ movement for a patient setup in the supine position. Breathing motion was modeled as sin(x), sin 4 (x), and sin 6 (x), based on functions used in the literature to represent organ motion. Measurements were performed with an ionization chamber and films. For a systematic study of motion effects, a MATLAB simulation was written to model organ movement and dose delivery. In the case of a single beam made up of one single segment, the dose delivered to point in a moving target over 30 fractions can vary up to 20% and 10% for segments of 10 MU and 20 MU, respectively. This dose error occurs because the tumor spends most of the time near the edges of the radiation beam. In the case of a single beam made of multiple segments with low MU, we observed 2.4%, 3.3%, and 4.3% differences, respectively, for sin(x), sin 4 (x), and sin 6 (x) motion, between delivered dose and motion-averaged dose for points in the penumbra region of the beam and over 30 fractions. In approximately 5-10% of the cases, differences between the motion-averaged dose

  16. Examination of muscle composition and motor unit behavior of the first dorsal interosseous of normal and overweight children.

    Science.gov (United States)

    Miller, Jonathan D; Sterczala, Adam J; Trevino, Michael A; Herda, Trent J

    2018-05-01

    We examined differences between normal weight (NW) and overweight (OW) children aged 8-10 yr in strength, muscle composition, and motor unit (MU) behavior of the first dorsal interosseous. Ultrasonography was used to determine muscle cross-sectional area (CSA), subcutaneous fat (sFAT), and echo intensity (EI). MU behavior was assessed during isometric muscle actions at 20% and 50% of maximal voluntary contraction (MVC) by analyzing electromyography amplitude (EMG RMS ) and relationships between mean firing rates (MFR), recruitment thresholds (RT), and MU action potential amplitudes (MUAP size ) and durations (MUAP time ). The OW group had significantly greater EI than the NW group ( P = 0.002; NW, 47.99 ± 6.01 AU; OW, 58.90 ± 10.63 AU, where AU is arbitrary units) with no differences between groups for CSA ( P = 0.688) or MVC force ( P = 0.790). MUAP size was larger for NW than OW in relation to RT ( P = 0.002) and for MUs expressing similar MFRs ( P = 0.011). There were no significant differences ( P = 0.279-0.969) between groups for slopes or y-intercepts from the MFR vs. RT relationships. MUAP time was larger in OW ( P = 0.015) and EMG RMS was attenuated in OW compared with NW ( P = 0.034); however, there were no significant correlations ( P = 0.133-0.164, r = 0.270-0.291) between sFAT and EMG RMS . In a muscle that does not support body mass, the OW children had smaller MUAP size as well as greater EI, although anatomical CSA was similar. This contradicts previous studies examining larger limb muscles. Despite evidence of smaller MUs, the OW children had similar isometric strength compared with NW children. NEW & NOTEWORTHY Ultrasound data and motor unit action potential sizes suggest that overweight children have poorer muscle composition and smaller motor units in the first dorsal interosseous than normal weight children. Evidence is presented that suggests differences in action potential size cannot be explained

  17. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    International Nuclear Information System (INIS)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program

  18. Monitoring the World Health Organization Global Target 2025 for Exclusive Breastfeeding: Experience From the United States.

    Science.gov (United States)

    Gupta, Priya M; Perrine, Cria G; Chen, Jian; Elam-Evans, Laurie D; Flores-Ayala, Rafael

    2017-08-01

    Exclusive breastfeeding under 6 months, calculated from a single 24-hour recall among mothers of children 0 to 5 months of age, is a World Health Organization (WHO) indicator used to monitor progress on the 2025 global breastfeeding target. Many upper-middle-income and high-income countries, including the United States, do not have estimates for this indicator. Research aim: To describe the prevalence of exclusive breastfeeding under 6 months in the United States. We used a single 24-hour dietary recall from the National Health and Nutrition Examination Survey 2009-2012 to calculate the prevalence of exclusive breastfeeding under 6 months. We discuss our results in the context of routine breastfeeding surveillance, which is reported from a national survey with different methodology. Among children younger than 6 months, 24.4%, 95% confidence interval [17.6, 31.1], were exclusively breastfed the previous day. To our knowledge, this is the first estimate of the WHO indicator of exclusive breastfeeding under 6 months for the United States. This study supports the global surveillance and data strategy for reporting to the WHO on the 2025 target for exclusive breastfeeding.

  19. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    International Nuclear Information System (INIS)

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q.

    2015-01-01

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery

  20. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Taoran, E-mail: taoran.li.duke@gmail.com; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q. [Department of Radiation Oncology, Duke University Medical Center Durham, North Carolina 27710 (United States)

    2015-01-15

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery

  1. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.

    Science.gov (United States)

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q

    2015-01-01

    An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system's performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Online adapted plans were

  2. Radiation protection and monitoring

    International Nuclear Information System (INIS)

    Thomas, P.

    1982-01-01

    The present paper deals with the following topics: - Radiological quantities and units - Principles of radiological protection - Limits of doses and activity uptake - Activity discharges and monitoring - Radiation exposure and its calculation - Environmental monitoring - Personnel dosimetry. (orig./RW)

  3. An Improved Calibration Method for Hydrazine Monitors for the United States Air Force

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K

    2003-07-07

    This report documents the results of Phase 1 of the ''Air Force Hydrazine Detector Characterization and Calibration Project''. A method for calibrating model MDA 7100 hydrazine detectors in the United States Air Force (AF) inventory has been developed. The calibration system consists of a Kintek 491 reference gas generation system, a humidifier/mixer system which combines the dry reference hydrazine gas with humidified diluent or carrier gas to generate the required humidified reference for calibrations, and a gas sampling interface. The Kintek reference gas generation system itself is periodically calibrated using an ORNL-constructed coulometric titration system to verify the hydrazine concentration of the sample atmosphere in the interface module. The Kintek reference gas is then used to calibrate the hydrazine monitors. Thus, coulometric titration is only used to periodically assess the performance of the Kintek reference gas generation system, and is not required for hydrazine monitor calibrations. One advantage of using coulometric titration for verifying the concentration of the reference gas is that it is a primary standard (if used for simple solutions), thereby guaranteeing, in principle, that measurements will be traceable to SI units (i.e., to the mole). The effect of humidity of the reference gas was characterized by using the results of concentrations determined by coulometric titration to develop a humidity correction graph for the Kintek 491 reference gas generation system. Using this calibration method, calibration uncertainty has been reduced by 50% compared to the current method used to calibrate hydrazine monitors in the Air Force inventory and calibration time has also been reduced by more than 20%. Significant findings from studies documented in this report are the following: (1) The Kintek 491 reference gas generation system (generator, humidifier and interface module) can be used to calibrate hydrazine detectors. (2) The

  4. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program.

  5. Monitoring Activities Review action report for the Environmental Monitoring Program

    International Nuclear Information System (INIS)

    Wilhelmsen, R.N.; Wright, K.C.

    1990-12-01

    To improve program planning and to provide bases for technical improvement of the monitoring program, the EG ampersand G Environmental Monitoring (EM) organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. An MAR of the Environmental Monitoring Program was conducted in 1988. This action report identifies and discusses the recommendations of this MAR committee. This action report also identifies the actions already taken by the EM Unit in response to these recommendations, as well as the actions and schedules to be taken. 10 refs

  6. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data ...

  7. No evidence for punishment in communally nursing female house mice (Mus musculus domesticus).

    Science.gov (United States)

    Ferrari, Manuela; König, Barbara

    2017-01-01

    Punishment is claimed as an important mechanism to stabilise costly cooperation in humans, but its importance in social animals has been questioned recently due to both conceptual considerations and a lack of empirical evidence (only few published studies). We empirically tested whether there is evidence for punishment in communally nursing house mice (Mus musculus domesticus, direct descendants of "wild" animals). Communally breeding females pool their litters and raise all offspring together, indiscriminately caring for own and other offspring. Such a situation resembles a public good and provides scope for exploitation if females vary in their relative contributions to the joint nest (offspring number). We allowed two females to communally breed and conducted removal experiments both in the presence and absence of pups. We aimed to test whether reduced investment by one of the females (induced through separation from the partner and their combined offspring for 4 or 12 hours) leads to increased aggression by the other female after the reunion. We found no evidence for punishment, on the contrary, females increased socio-positive behaviours. The costs of losing a partner in a communally breeding species might be too high and hinder the evolution of punishment. Our findings add to a growing list of examples questioning the role of punishment in cooperating non-human animals and emphasise the importance of empirical testing of its assumptions and predictions.

  8. Comparison between In-house developed and Diamond commercial software for patient specific independent monitor unit calculation and verification with heterogeneity corrections.

    Science.gov (United States)

    Kuppusamy, Vijayalakshmi; Nagarajan, Vivekanandan; Jeevanandam, Prakash; Murugan, Lavanya

    2016-02-01

    The study was aimed to compare two different monitor unit (MU) or dose verification software in volumetric modulated arc therapy (VMAT) using modified Clarkson's integration technique for 6 MV photons beams. In-house Excel Spreadsheet based monitor unit verification calculation (MUVC) program and PTW's DIAMOND secondary check software (SCS), version-6 were used as a secondary check to verify the monitor unit (MU) or dose calculated by treatment planning system (TPS). In this study 180 patients were grouped into 61 head and neck, 39 thorax and 80 pelvic sites. Verification plans are created using PTW OCTAVIUS-4D phantom and also measured using 729 detector chamber and array with isocentre as the suitable point of measurement for each field. In the analysis of 154 clinically approved VMAT plans with isocentre at a region above -350 HU, using heterogeneity corrections, In-house Spreadsheet based MUVC program and Diamond SCS showed good agreement TPS. The overall percentage average deviations for all sites were (-0.93% + 1.59%) and (1.37% + 2.72%) for In-house Excel Spreadsheet based MUVC program and Diamond SCS respectively. For 26 clinically approved VMAT plans with isocentre at a region below -350 HU showed higher variations for both In-house Spreadsheet based MUVC program and Diamond SCS. It can be concluded that for patient specific quality assurance (QA), the In-house Excel Spreadsheet based MUVC program and Diamond SCS can be used as a simple and fast accompanying to measurement based verification for plans with isocentre at a region above -350 HU. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. POST-CLOSURE INSPECTION AND MONITORING REPORT FOR CORRECTIVE ACTION UNIT 112: AREA 23 HAZARDOUS WASTE TRENCHES, NEVADA TEST SITE, NEVADA; FOR THE PERIOD OCTOBER 2003 - SEPTEMBER 2004

    International Nuclear Information System (INIS)

    BECHTEL NEVADA

    2004-01-01

    Corrective Action Unit (CAU) 112, Area 23 Hazardous Waste Trenches, Nevada Test Site (NTS), Nevada, is a Resource Conservation and Recovery Act (RCRA) unit located in Area 23 of the NTS. This annual Post-Closure Inspection and Monitoring Report provides the results of inspections and monitoring for CAU 112. This report includes a summary and analysis of the site inspections, repair and maintenance, meteorological information, and neutron soil moisture monitoring data obtained at CAU 112 for the current monitoring period, October 2003 through September 2004. Inspections of the CAU 112 RCRA unit were performed quarterly to identify any significant physical changes to the site that could impact the proper operation of the waste unit. The overall condition of the covers and facility was good, and no significant findings were observed. The annual subsidence survey of the elevation markers was conducted on August 23, 2004, and the results indicated that no cover subsidence4 has occurred at any of the markers. The elevations of the markers have been consistent for the past 11 years. The total precipitation for the current reporting period, october 2003 to September 2004, was 14.0 centimeters (cm) (5.5 inches [in]) (National Oceanographic and Atmospheric Administration, Air Resources Laboratory, Special Operations and Research Division, 2004). This is slightly below the average rainfall of 14.7 cm (5.79 in) over the same period from 1972 to 2004. Post-closure monitoring verifies that the CAU 112 trench covers are performing properly and that no water is infiltrating into or out of the waste trenches. Sail moisture measurements are obtained in the soil directly beneath the trenches and compared to baseline conditions for the first year of post-closure monitoring, which began in october 1993. neutron logging was performed twice during this monitoring period along 30 neutron access tubes to obtain soil moisture data and detect any changes that may indicate moisture movement

  10. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1983

    International Nuclear Information System (INIS)

    Patzer, R.G.; Black, S.C.; Grossman, R.F.; Smith, D.D.

    1984-07-01

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with standards, to identify trends in environmental radiation, and to provide such information to the public. It summarizes these activities for calendar year 1983. No radioactivity attributable to NTS activities was detectable offsite by the monitoring networks. Using recorded wind data and Pasquill stability categories, atmospheric dispersion calculations based on reported radionuclide releases yield an estimated dose of 5 x 10 -5 man-rem to the population within 80 km of the Nevada Test Site during 1983. World-wide fallout of Kr-85, Sr-90, Cs-137, and Pu-239 detected by the monitoring networks would cause maximum exposure to an individual of less than 0.2 mrem per year. Plutonium and krypton in air were similar to 1982 levels while cesium and strontium in other samples were near the detection limits. An occasional net exposure to offsite residents has been detected by the TLD network. On investigation, the cause of such net exposures has been due to personal habits or occupational activities, not to NTS activities. 29 references, 35 figures, 30 tables

  11. Monitoring the consistency of the dynalyser output via digital display unit and calculated practical peak voltage

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Muhammad Jamal Mohd Isa; Abdul Aziz Mohd Ramli; Shahrul Azlan Azizan

    2010-01-01

    This study was carried out to ensure the adequacy and accuracy of the Dynalyser Digital Display unit for measuring the true kVp from the invasive kVp meter unit during calibration of non-invasive kVp meters. An invasive high voltage divider (dynalyser) coupled to the x-ray system measures the true kilo voltage supplied to the x-ray tube. The kVp output measured was displayed via its digital display unit while its waveform was acquired using a calibrated oscilloscope. The waveform was used to calculate the Practical Peak Voltage (PPV) using the International Standard method adapted from IEC 61676 and treated as the true kVp value. The kVp output was measured at 9 points ranging between 40 kV-120 kV with interval steps of 10 kV and monitored every day. The test result was evaluated for variation of output, intrinsic error and limit of variation in compliance with the IEC standard. Results showed that kVp output measured by the display unit everyday is consistent with variations of not more than ±0.45 kV, intrinsic error of not more than ±0.009 kV and limits of variation of less than 1% which comply with the IEC standard requirement. The kVp output via digital display unit has a total uncertainty of not more than 2.8 kV (k=2) while the PPV output via oscilloscope has total uncertainty of not more than 0.75 kV (k=2). As a conclusion, the dynalyser digital display unit complies with standard requirement and can be used to measure the true kVp output during the calibration of non-invasive kVp meters. (author)

  12. The Emergency Radiological Monitoring and Analysis Division of the United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    2000-01-01

    The U.S. Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorises the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to co-ordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted States and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for co-ordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. This program includes: 1. Aerial Radiological Monitoring - Fixed-Wing and Helicopter; 2. Field Monitoring and Sampling; 3. Radioanalysis - Mobile and Fixed Laboratories; 4. Radiation Detection Instrumentation - Calibration and Maintenance; 5. Environmental Dosimetry; 6. Integrated program of Quality Assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC Monitoring and Analysis Division and the content and preparation of the manual. (author)

  13. Wireless sensor and data transmission needs and technologies for patient monitoring in the operating room and intensive care unit.

    Science.gov (United States)

    Paksuniemi, M; Sorvoja, H; Alasaarela, E; Myllyla, R

    2005-01-01

    In the intensive care unit, or during anesthesia, patients are attached to monitors by cables. These cables obstruct nursing staff and hinder the patients from moving freely in the hospital. However, rapidly developing wireless technologies are expected to solve these problems. To this end, this study revealed problem areas in current patient monitoring and established the most important medical parameters to monitor. In addition, usable wireless techniques for short-range data transmission were explored and currently employed wireless applications in the hospital environment were studied. The most important parameters measured of the patient include blood pressures, electrocardiography, respiration rate, heart rate and temperature. Currently used wireless techniques in hospitals are based on the WMTS and WLAN standards. There are no viable solutions for short-range data transmission from patient sensors to patient monitors, but potentially usable techniques in the future are based on the WPAN standards. These techniques include Bluetooth, ZigBee and UWB. Other suitable techniques might be based on capacitive or inductive coupling. The establishing of wireless techniques depends on ensuring the reliability of data transmission, eliminating disturbance by other wireless devices, ensuring patient data security and patient safety, and lowering the power consumption and price.

  14. Les vélins du Muséum national d’histoire naturelle : une collection mise en lumière

    OpenAIRE

    Cardinal, Catherine

    2018-01-01

    Une exposition unique au Cabinet d’histoire du Jardin des plantes Très rarement, le public a pu voir la collection d’images de fleurs, de plantes, d’oiseaux et de mammifères, déposée à la bibliothèque centrale du Musée national d’histoire naturelle. La fragilité des peintures sur vélin au contact de l’air humide et de la lumière explique les précautions prises à leur égard. L’exposition d’environ cent cinquante pièces au sein du Cabinet d’histoire, d’octobre 2016 à janvier 2017, a donc consti...

  15. Radioactivity monitoring in Romania

    International Nuclear Information System (INIS)

    Alexandrescu, M.; Milu, C.

    1996-01-01

    Radioactivity monitoring in Romania is based on National Regulations for Radiation Protection enforced in 1976, on other environment protection laws enforced in the last years and on the recommendations of IAEA. Accordingly two systems of radioactive monitoring are to date operational in this field: the first one is the self-control of the radioactive emissions in the environment generated by the own nuclear activities (of nuclear units like the Cernavoda NPP, the Institute of Atomic Physics at Magurele-Bucharest, the Institute for Nuclear Research at Pitesti, the R Plant at Feldioara, Uranium mining units, etc.), while the other is based on two national agencies (the National Network of Environment Radiation Monitoring of the Ministry of Waters, Forests and Environment Protection and the Network of Radiation Hygiene Laboratories of the Health Ministry). The authors review and discuss the radiation protection legislation, the structure and the organizational operations of the national monitoring systems and the co-operation of the national monitoring systems with international authorities or programmes. 3 Figs., 1 tab., 11 refs

  16. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu; Yoshioka, Yuzuru.

    1996-01-01

    The authors have been developing a measurement system for bubbly flow in order to clarify its multi-dimensional flow characteristics and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system combining an ultrasonic velocity profile monitor with a video data processing unit is proposed, which can measure simultaneously velocity profiles in both gas and liquid phases, a void fraction profile for bubbly flow in a channel, and an average bubble diameter and void fraction. Furthermore, the proposed measurement system is applied to measure flow characteristics of a bubbly countercurrent flow in a vertical rectangular channel to verify its capability. (author)

  17. Generalized monitor unit calculation for the Varian enhanced dynamic wedge field

    International Nuclear Information System (INIS)

    Liu Chihray; Kim, Siyong; Kahler, Darren L.; Palta, Jatinder R.

    2003-01-01

    The generalized monitor unit (MU) calculation equation for the Varian enhanced dynamic wedge (EDW) is derived. The assumption of this MU calculation method is that the wedge factor of the EDW at the center of the field is a function of field size, the position of the center of the field in the wedge direction, and the final position of the moving jaw. The wedge factors at the center of the field in both symmetric and asymmetric fields are examined. The difference between calculated and measured wedge factors is within 1.0%. The method developed here is easy to implement. The only datum required in addition to the standard set of conventional physical wedge implementation data is the off-axis output factor for the open field in the reference condition. The off-center point calculation is also examined. For the off-center point calculation, the dose profile in the wedge direction for the largest EDW field is used to obtain the relative off-center ratio in any smaller wedge field. The accuracy of the off-center point calculation decreases when the point of calculation is too close to the field edge

  18. Context dependence of acorn handling by the Algerian mouse (Mus spretus)

    Science.gov (United States)

    Gallego, D.; Morán-López, T.; Torre, I.; Navarro-Castilla, Á.; Barja, I.; Díaz, M.

    2017-10-01

    Perceived predation risk and competition for acorns are expected to affect scatter-hoarding decisions by Algerian mice (Mus spretus). We manipulated both factors by means of predator fecal scents and ungulate exclosures. We hypothesized that high-risk perception and ungulate presence would promote acorn dispersal. In the former case, it would stimulate acorn mobilization to safe microhabitats rather than in situ consumption. In the latter, increased competition for acorns would promote their storage for later consumption. We also expected that mice would adapt their foraging behavior to previous experience modulating the strength of these effects. In the presence of ungulates, mice focused their foraging activities on food acquisition at the expenses of vigilant behaviors. However, a more efficient foraging did not entail enhanced dispersal services. Lack of anti-predatory cover in tree surroundings may have deterred mice from transporting seeds outside canopies. Increased risk interacted with previous experience. In control trees (no predator odor), mice confidence increased throughout the night resulting in decreased vigilance and enhanced acorn mobilization rates. In contrast, in risky conditions (trees with predator odor) mice maintained a base-line vigilant behavior. Contrary to our expectations, increased risk did not result in higher acorn mobilization, but the opposite. Again, the scarcity of safe microhabitats for mobilization may have been the underlying cause of this behavior. Our results show that successful acorn dispersal depends, at least partly, on plant-animal relationships that are beyond the oak-rodent mutualism. Thus, any conservation policy aimed at restoring natural regeneration of oaks should take into account the interaction network in which oak-rodent encounters are embedded. In addition, they suggest that mice incorporate direct and indirect cues of risks (habitat structure) through recent experience. A better understanding of this process

  19. Presencia de los géneros invasores Mus y Rattus en áreas naturales de Chile: un riesgo ambiental y epidemiológico Presence of the invasive genera Mus and Rattus in natural areas in Chile: an environmental and epidemiological risk

    Directory of Open Access Journals (Sweden)

    GABRIEL LOBOS

    2005-03-01

    Full Text Available Realizamos un estudio que incluyó muestreos y prospecciones en un gradiente latitudinal en Chile continental para determinar la presencia y ausencia de roedores murinos introducidos, particularmente Mus musculus, Rattus rattus y R. norvegicus en áreas naturales o silvestres a lo largo de Chile. Además se analizó el riesgo epidemiológico que representan estas especies en el marco de un estudio sobre el virus Hanta. Los resultados mostraron que M. musculus rara vez es recolectado en áreas naturales. Sin embargo, las dos especies de Rattus han invadido ampliamente la región mediterránea chilena. Las regiones desérticas, los ambientes de alturas y las regiones australes, serían biótopos restringidos para estos invasores. Desde una perspectiva epidemiológica, la presencia del virus Hanta (variedades Andes y Seoul en Rattus es un elemento que demuestra que las especies invasoras además de generar impactos ecológicos, pueden ocasionar problemas económicos y de salud pública. La fragilidad de los ecosistemas mediterráneos determina que la presencia de especies exóticas constituya un elemento de alto riesgo para la conservación del patrimonio natural del país. Probablemente, la conservación de áreas naturales constituye la mejor herramienta para enfrentar a estas especies exóticasWe conducted a latitudinal study in natural areas of continental Chile to evaluate the occurrence of the introduced murine rodents Mus musculus, Rattus rattus and R. norvegicus. Furthermore, we evaluated the epidemiological risk of these species as part of an ongoing study on Hantavirus. The results allowed us to conclude that M. musculus occurs rarely in natural environments. However, the two species of Rattus have widely invaded the mediterranean region of Chile. Desert, altitudinal and high latitude regions seem to be restricted areas for these invasive rodents. From an epidemiological perspective, the occurrence of Hantavirus in Rattus (Andes and Seoul

  20. Compact toroid injection system for JFT-2M

    Energy Technology Data Exchange (ETDEWEB)

    Fukumoto, N. [University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan)]. E-mail: fukumotn@eng.u-hyogo.ac.jp; Ogawa, H. [Japan Atomic Energy Agency (JAEA), 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Nagata, M. [University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Uyama, T. [University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Shibata, T. [Japan Atomic Energy Agency (JAEA), 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Kashiwa, Y. [Japan Atomic Energy Agency (JAEA), 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Suzuki, S. [Japan Atomic Energy Agency (JAEA), 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Kusama, Y. [Japan Atomic Energy Agency (JAEA), 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2006-11-15

    The compact toroid (CT) injection system for JFT-2M is composed of a CT injector, a gas delivery and vacuum system, a power supply system, and a diagnostics system. In particular, the power supply system delivers high performance for CT formation and acceleration. The CT formation capacitor bank unit achieved a formation current of 350 kA with a rise time less than 10 {mu}s. Although the CT acceleration bank units are equipped with 14 ignitron switches instead of gap switches to attenuate the discharge noise level, an acceleration current of 400 kA with a short rise time of 9 {mu}s is controlled within a jitter of much less than 1 {mu}s. The resulting CT velocity and mass density satisfy the requirements for CT penetration into the tokamak plasma core at a toroidal field of 1 T. This CT injection system is thus suitable for CT injection in a middle-sized tokamak plasma such as the JFT-2M tokamak.

  1. Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit

    Science.gov (United States)

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations ...

  2. Robotic weed monitoring

    DEFF Research Database (Denmark)

    Bochtis, Dionysis; Sørensen, Claus Aage Grøn; Jørgensen, R N

    2011-01-01

    Abstract: In this paper, an integrated management system for the planning and activation of thefield monitoring task is presented. The architecture of the system is built around a mobile roboticunit. The internet based architecture of the system includes a station unit that works as a mobileon-fa...... of the weed monitoring operation.Key words: autonomous vehicles, farm management, mission planning, route planning,sampling....

  3. Comparative analysis of Homo sapiens and Mus musculus cyclin-dependent kinase (CDK) inhibitor genes p16 (MTS1) and p15 (MTS2).

    Science.gov (United States)

    Jiang, P; Stone, S; Wagner, R; Wang, S; Dayananth, P; Kozak, C A; Wold, B; Kamb, A

    1995-12-01

    Cyclin-dependent kinase inhibitors are a growing family of molecules that regulate important transitions in the cell cycle. At least one of these molecules, p16, has been implicated in human tumorigenesis while its close homolog, p15, is induced by cell contact and transforming growth factor-beta (TGF-beta). To investigate the evolutionary and functional features of p15 and p16, we have isolated mouse (Mus musculus) homologs of each gene. Comparative analysis of these sequences provides evidence that the genes have similar functions in mouse and human. In addition, the comparison suggests that a gene conversion event is part of the evolution of the human p15 and p16 genes.

  4. XY females do better than the XX in the African pygmy mouse, Mus minutoides.

    Science.gov (United States)

    Saunders, Paul A; Perez, Julie; Rahmoun, Massilva; Ronce, Ophélie; Crochet, Pierre-André; Veyrunes, Frédéric

    2014-07-01

    All therian mammals have a similar XY/XX sex-determination system except for a dozen species. The African pygmy mouse, Mus minutoides, harbors an unconventional system in which all males are XY, and there are three types of females: the usual XX but also XX* and X*Y ones (the asterisk designates a sex-reversal mutation on the X chromosome). The long-term evolution of such a system is a paradox, because X*Y females are expected to face high reproductive costs (e.g., meiotic disruption and loss of unviable YY embryos), which should prevent invasion and maintenance of a sex-reversal mutation. Hence, mechanisms for compensating for the costs could have evolved in M. minutoides. Data gathered from our laboratory colony revealed that X*Y females do compensate and even show enhanced reproductive performance in comparison to the XX and XX*; they produce significantly more offspring due to (i) a higher probability of breeding, (ii) an earlier first litter, and (iii) a larger litter size, linked to (iv) a greater ovulation rate. These findings confirm that rare conditions are needed for an atypical sex-determination mechanism to evolve in mammals, and provide valuable insight into understanding modifications of systems with highly heteromorphic sex chromosomes. © 2014 The Author(s). Evolution © 2014 The Society for the Study of Evolution.

  5. NPP Mochovce units 1 and 2 diagnostic systems

    International Nuclear Information System (INIS)

    Heidenreich, S.

    1997-01-01

    In this paper the diagnostic systems (leak detection monitoring, vibration monitoring, lose parts monitoring, fatigue monitoring) of NPP Mochovce units 1 and 2 are presented. All of the designed diagnostic systems are personal computer based systems

  6. System for remote routine monitoring of power equipment at TPP and NPP

    International Nuclear Information System (INIS)

    Kantsedalov, V.G.; Samojlenko, V.P.; Doroshenko, V.A.

    1988-01-01

    A system for remote routine monitoring of TPP and NPP pipeline metals is described. The principal functional unit of the system is the unit of remote routine methods and techniques for studying and monitoring the metal and properties. The system is equipped with 5 types of routine monitoring equipment: robots, remote aggregated complexes, periodical diagnostic monitors, other means of metal diagnostics (endoscopes, introscopes). All current information enters the unit for estimating and forecasting the service life of power unit, where it is compared with the standard indices of reliability, duravility and efficiency. The system considered permits to reduce significantly or minimize the scope of works on metal monitoring during overhauls, increase intermonitoring and interrepairing compaigns to 8 years

  7. Laju peningkatan konsentrasi timbal Pb dalam darah hewan uji mencit Mus musculus di bengkel otomotif

    Directory of Open Access Journals (Sweden)

    Mohammad Razif Sukatma

    2012-02-01

    Full Text Available This research was conducted in automotive workshop of VEDC Malang and the samples were taken at the automotive machineand automotive electric workshops. The parameters which examined were the Pb concentration in the mouse blood (Mus musculus in2 and 3 months years old. The measurement was run for 5 times every 10 days, and the result was mean value of the increasing rate ofPb concentration in the mouse blood. The aim of this research was to determine the increasing rate of Pb concentration in the mouseblood which has the relation with different working area, different age, and also duration of exposure. Based on the data of laboratorytest, research continued by T-test analysis, Simple regression test, and correlation, and also General Linear Model. By doing statisticanalysis with the different working area, duration of explanation, and different age.Result of this research showed that there were the differences of rapid increasing of Pb concentration in both workshop. Generallythe age which influence so much for that (in the mouse body and have the relation with the body stamina. If the mouse body absorbamount of Pb constantly, so the Pb concentration in it will increase more and more and it cause the decreasing of the body height.

  8. Molecular heterogeneity in major urinary proteins of Mus musculus subspecies: potential candidates involved in speciation

    Science.gov (United States)

    Hurst, Jane L.; Beynon, Robert J.; Armstrong, Stuart D.; Davidson, Amanda J.; Roberts, Sarah A.; Gómez-Baena, Guadalupe; Smadja, Carole M.; Ganem, Guila

    2017-01-01

    When hybridisation carries a cost, natural selection is predicted to favour evolution of traits that allow assortative mating (reinforcement). Incipient speciation between the two European house mouse subspecies, Mus musculus domesticus and M.m.musculus, sharing a hybrid zone, provides an opportunity to understand evolution of assortative mating at a molecular level. Mouse urine odours allow subspecific mate discrimination, with assortative preferences evident in the hybrid zone but not in allopatry. Here we assess the potential of MUPs (major urinary proteins) as candidates for signal divergence by comparing MUP expression in urine samples from the Danish hybrid zone border (contact) and from allopatric populations. Mass spectrometric characterisation identified novel MUPs in both subspecies involving mostly new combinations of amino acid changes previously observed in M.m.domesticus. The subspecies expressed distinct MUP signatures, with most MUPs expressed by only one subspecies. Expression of at least eight MUPs showed significant subspecies divergence both in allopatry and contact zone. Another seven MUPs showed divergence in expression between the subspecies only in the contact zone, consistent with divergence by reinforcement. These proteins are candidates for the semiochemical barrier to hybridisation, providing an opportunity to characterise the nature and evolution of a putative species recognition signal. PMID:28337988

  9. Effect of Physalis peruviana "tomatillo" fruit extract in Mus musculus var. swis with induced hyperlipidemi.

    Directory of Open Access Journals (Sweden)

    Julio Campos Florián

    2011-06-01

    Full Text Available The objective of this research was to determine the hypolipidemic activity of the fruit of Physalis peruviana "tomatillo" in a model of acute hyperlipidemia induced by triton. Mus musculus var. swis males as experimental animals. We worked with four groups of mice, the white group received distilled water orally and saline intraperitoneally, the control group received distilled water orally and intraperitoneally triton, the problem group 1 received orally 0.05g/100g Physalis peruviana extract intraperitoneally and triton and the problem group 2 received orally 0.2g/100g extract of Physalis peruviana and triton intraperitoneally. After 24 hours of administering the treatments were performed measurements of serum cholesterol and triglycerides. Mean levels of cholesterol (mg/dL were: 58.87 ± 11.54 (white, 121.71 ± 15.00 (control, 58.08 ± 9.21 (Problem 1 and 66 78 ± 16.77 (Problem 2. Average levels of triglycerides (g /L were: 0.48 ± 0.07 (white, 1.84 ± 0.18 (control, 0.34 ± 0.10 (Problem 1 and 0.94 ± 0.25 (Problem 2. We found significant reductions (p <0.000 concentrations of both cholesterol and triglycerides in relation to those obtained in the group treated only with Triton.

  10. POST-CLOSURE INSPECTION AND MONITORING REPORT FOR CORRECTIVE ACTION UNIT 91: AREA 3 U3 fi INJECTION WELL, NEVADA TEST SITE, NEVADA FOR THE PERIOD NOVEMBER 2003 - OCTOBER 2004

    International Nuclear Information System (INIS)

    2005-01-01

    This Post-Closure Inspection and Monitoring report provides an analysis and summary of inspections, meteorological information, and neutron soil moisture monitoring for Corrective Action Unit (CAU) 91: Area 3 U-3fi Injection Well, Nevada Test Site (NTS), Nevada. This report covers the annual period November 2003 through October 2004. Site inspections of CAU 91 are performed every six months to identify any significant changes that could impact the proper operation of the waste disposal unit. Inspection results for the current period indicate that the overall condition of the concrete pad, perimeter fence, and warning signs is good

  11. Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario.

    Science.gov (United States)

    Mishra, Bibekananda; Selvam, T Palani; Sharma, P K Dash

    2017-01-01

    Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP) Report No. 151 and the other based on the monitor units (MUs) delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  12. Off-site environmental monitoring report: radiation monitoring around United States nuclear test areas, calendar year 1984

    International Nuclear Information System (INIS)

    Potter, G.D.; Black, S.C.; Grossman, R.F.; Patzer, R.G.; Smith, D.D.

    1985-04-01

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with standards, to identify trends in environmental radiation, and to provide such information to the public. It summarizes these activities for calendar year 1984. No radioactivity attributable to NTS activities was detectable offsite by the monitoring networks. Using recorded wind data and Pasquill stability categories, atmospheric dispersion calculations based on reported radionuclides releases yield an estimated dose of 1 x 10 -3 person-rem to the population within 80 km of the Nevada Test Site during 1983. World-wide fallout of Kr-85, Sr-90, Cs-137, and Pu-239 detected by the monitoring networks would cause maximum exposure to an individual of less than 0.6 mrem per year. Plutonium in air was still detectable along with krypton-85, which continued its gradual increase, as has been reported previously. Cesium and strontium in air were near their detection limits. An occasional net exposure to offsite residents has been detected by the TLD network. On investigation, the cause of such net exposures has been due to personal habits or occupational activities, not to NTS activities. 32 refs., 36 figs., 27 tabs

  13. Structural damage monitoring of harbor caissons with interlocking condition

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, Thanh Canh; Lee, So Young; Nauyen, Khac Duy; Kim, Jeong Tae [Pukyong National Univ., Busan (Korea, Republic of)

    2012-12-15

    The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons.

  14. Structural damage monitoring of harbor caissons with interlocking condition

    International Nuclear Information System (INIS)

    Huynh, Thanh Canh; Lee, So Young; Nauyen, Khac Duy; Kim, Jeong Tae

    2012-01-01

    The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons

  15. Technology monitoring; Technologie-Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eicher, H.; Rigassi, R. [Eicher und Pauli AG, Liestal (Switzerland); Ott, W. [Econcept AG, Zuerich (Switzerland)

    2003-07-01

    This study made for the Swiss Federal Office of Energy (SFOE) examines ways of systematically monitoring energy technology development and the cost of such technologies in order to pave the way to a basis for judging the economic development of new energy technologies. Initial results of a survey of the past development of these technologies are presented and estimates are made of future developments in the areas of motor-based combined heat and power systems, fuel-cell heating units for single-family homes and apartment buildings, air/water heat pumps for new housing projects and high-performance thermal insulation. The methodology used for the monitoring and analysis of the various technologies is described. Tables and diagrams illustrate the present situation and development potential of various fields of technology.

  16. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  17. Dynamics of a Tularemia Outbreak in a Closely Monitored Free-Roaming Population of Wild House Mice.

    Science.gov (United States)

    Dobay, Akos; Pilo, Paola; Lindholm, Anna K; Origgi, Francesco; Bagheri, Homayoun C; König, Barbara

    2015-01-01

    Infectious disease outbreaks can be devastating because of their sudden occurrence, as well as the complexity of monitoring and controlling them. Outbreaks in wildlife are even more challenging to observe and describe, especially when small animals or secretive species are involved. Modeling such infectious disease events is relevant to investigating their dynamics and is critical for decision makers to accomplish outbreak management. Tularemia, caused by the bacterium Francisella tularensis, is a potentially lethal zoonosis. Of the few animal outbreaks that have been reported in the literature, only those affecting zoo animals have been closely monitored. Here, we report the first estimation of the basic reproduction number R0 of an outbreak in wildlife caused by F. tularensis using quantitative modeling based on a susceptible-infected-recovered framework. We applied that model to data collected during an extensive investigation of an outbreak of tularemia caused by F. tularensis subsp. holarctica (also designated as type B) in a closely monitored, free-roaming house mouse (Mus musculus domesticus) population in Switzerland. Based on our model and assumptions, the best estimated basic reproduction number R0 of the current outbreak is 1.33. Our results suggest that tularemia can cause severe outbreaks in small rodents. We also concluded that the outbreak self-exhausted in approximately three months without administrating antibiotics.

  18. Dynamics of a Tularemia Outbreak in a Closely Monitored Free-Roaming Population of Wild House Mice.

    Directory of Open Access Journals (Sweden)

    Akos Dobay

    Full Text Available Infectious disease outbreaks can be devastating because of their sudden occurrence, as well as the complexity of monitoring and controlling them. Outbreaks in wildlife are even more challenging to observe and describe, especially when small animals or secretive species are involved. Modeling such infectious disease events is relevant to investigating their dynamics and is critical for decision makers to accomplish outbreak management. Tularemia, caused by the bacterium Francisella tularensis, is a potentially lethal zoonosis. Of the few animal outbreaks that have been reported in the literature, only those affecting zoo animals have been closely monitored. Here, we report the first estimation of the basic reproduction number R0 of an outbreak in wildlife caused by F. tularensis using quantitative modeling based on a susceptible-infected-recovered framework. We applied that model to data collected during an extensive investigation of an outbreak of tularemia caused by F. tularensis subsp. holarctica (also designated as type B in a closely monitored, free-roaming house mouse (Mus musculus domesticus population in Switzerland. Based on our model and assumptions, the best estimated basic reproduction number R0 of the current outbreak is 1.33. Our results suggest that tularemia can cause severe outbreaks in small rodents. We also concluded that the outbreak self-exhausted in approximately three months without administrating antibiotics.

  19. Utilizing Physiological Principles of Motor Unit Recruitment to Reduce Fatigability of Electrically-Evoked Contractions: A Narrative Review.

    Science.gov (United States)

    Barss, Trevor S; Ainsley, Emily N; Claveria-Gonzalez, Francisca C; Luu, M John; Miller, Dylan J; Wiest, Matheus J; Collins, David F

    2018-04-01

    Neuromuscular electrical stimulation (NMES) is used to produce contractions to restore movement and reduce secondary complications for individuals experiencing motor impairment. NMES is conventionally delivered through a single pair of electrodes over a muscle belly or nerve trunk using short pulse durations and frequencies between 20 and 40Hz (conventional NMES). Unfortunately, the benefits and widespread use of conventional NMES are limited by contraction fatigability, which is in large part because of the nonphysiological way that contractions are generated. This review provides a summary of approaches designed to reduce fatigability during NMES, by using physiological principles that help minimize fatigability of voluntary contractions. First, relevant principles of the recruitment and discharge of motor units (MUs) inherent to voluntary contractions and conventional NMES are introduced, and the main mechanisms of fatigability for each contraction type are briefly discussed. A variety of NMES approaches are then described that were designed to reduce fatigability by generating contractions that more closely mimic voluntary contractions. These approaches include altering stimulation parameters, to recruit MUs in their physiological order, and stimulating through multiple electrodes, to reduce MU discharge rates. Although each approach has unique advantages and disadvantages, approaches that minimize MU discharge rates hold the most promise for imminent translation into rehabilitation practice. The way that NMES is currently delivered limits its utility as a rehabilitative tool. Reducing fatigability by delivering NMES in ways that better mimic voluntary contractions holds promise for optimizing the benefits and widespread use of NMES-based programs. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Food preferences and mound-building behaviour of the mound-building mice Mus spicilegus

    Science.gov (United States)

    Hölzl, Michaela; Krištofík, Ján; Darolová, Alžbeta; Hoi, Herbert

    2011-10-01

    Optimal foraging strategies and food choice are influenced by various factors, e.g. availability, size and caloric content of the food type and predation risk. However, food choice criteria may change when food is not eaten immediately but has to be carried to a storage site for later use. For example, handling time in terms of harvesting and transport time should be optimized, particularly when the risk of predation is high. Thus, it is not clear whether food selected by hoarding animals reflects their food preference due to intrinsic features of the food type, e.g. size, caloric or lipid content, or whether the food type selected is a compromise that also considers the handling time required for harvesting and transport. We investigate this question in relation to food hoarding behaviour in mound-building mice. In autumn, mound-building mice Mus spicilegus collect seeds and other plant material and cover it with soil. Such above-ground storage is quite unusual for rodents. Here, we investigated whether there is a relationship between the seed species preferred as building materials and those preferred for food. We conducted a seed preference test using three most collected weed species for mound building. Controlling factors like food availability or predation risk, mice prefer Setaria spp. as food, although Amaranthus spp. and Chenopodium spp. were preferentially harvested and stored. By including the availability of the three species, our experimental results were confirmed, namely, a clear preference for Setaria spp. Also, handling time and seed size revealed to influence plant choice.

  1. Meiotic synapsis of homogeneously staining regions (HSRs) in chromosome 1 of Mus musculus.

    Science.gov (United States)

    Winking, H; Reuter, C; Traut, W

    1993-05-01

    About 50 copies of a long-range repeat DNA family with a repeat size of roughly 100 kb and with sequence homology to mRNAs are clustered in the G-light band D of chromosome 1 of the house mouse, Mus musculus. We studied amplified versions of the cluster which are found in many wild populations of M. musculus. They are cytogenetically conspicuous as one or two C-band positive homogeneously staining regions (single- and double band HSRs) which increase the mitotic length of chromosome 1. The double band HSR was phylogenetically derived from a single band HSR by a paracentric inversion. In homozygous condition, such HSRs contribute, albeit not as much as expected from their mitotic length, to the synaptonemal complex (SC) length of chromosome 1. In HSR heterozygous animals an elongation of the SCs was not noticeable. In single band HSR heterozygous males, synapsis proceeds regularly and continuously from the distal telomere towards the centromeric end without forming buckles. Thus, the single band HSR has no adverse effect on pairing. The same straight pairing behaviour was found in the majority of double band HSR heterozygous spermatocytes. This shows that extensive nonhomologous pairing can take place in the earliest phase of synapsis. Synapsis was discontinuous, leaving the central part of the bivalent 1 asynapsed, in only 14.3% of double band HSR heterozygous cells. In such cells the chromosome 1 SC is completed at a later stage of meiosis. The delay is presumably an effect of the inversion that includes one HSR band and the segment between the two HSR bands.

  2. Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer

    Directory of Open Access Journals (Sweden)

    Fu Yuchuan

    2010-07-01

    Full Text Available Abstract Purpose To study the impacts of multileaf collimators (MLC width [standard MLC width of 10 mm (sMLC and micro-MLC width of 4 mm (mMLC] in the intensity-modulated radiotherapy (IMRT planning for the upper thoracic esophageal cancer (UTEC. Methods and materials 10 patients with UTEC were retrospectively planned with the sMLC and the mMLC. The monitor unites (MUs and dose volume histogram-based parameters [conformity index (CI and homogeneous index (HI] were compared between the IMRT plans with sMLC and with mMLC. Results The IMRT plans with the mMLC were more efficient (average MUs: 703.1 ± 68.3 than plans with the sMLC (average MUs: 833.4 ± 73.8 (p p 5 (3260.3 ± 374.0 vs 3404.5 ± 374.4/gEUD (1815.1 ± 281.7 vs 1849.2 ± 297.6 of the spinal cord, the V10 (33.2 ± 6.5 vs 34.0 ± 6.7, V20 (16.0 ± 4.6 vs 16.6 ± 4.7, MLD (866.2 ± 174.1 vs 887.9 ± 172.1 and gEUD (938.6 ± 175.2 vs 956.8 ± 171.0 of the lungs were observed in the plans with the mMLC, respectively (p Conclusions Comparing to the sMLC, the mMLC not only demonstrated higher efficiencies and more optimal target coverage, but also considerably improved the dose sparing of OARs in the IMRT planning for UTEC.

  3. Intensity modulated radiosurgery for the spine: Dosimetric impact of beamlet size variation in the leaf travel direction

    International Nuclear Information System (INIS)

    Kim, Joo Young; Shin, Hyun Soo; Kim, Ja Young; Park, Hyeli; Kim, Sung Joon

    2011-01-01

    Background and purpose: To investigate the dosimetric impact of beamlet size in the leaf travel direction for the spinal treatment using intensity-modulated radiosurgery (IMRS). Materials and methods: The IMRS plans of ten patients (11 lesions - 6 thoracic, 2 cervical, 3 lumbar) were re-planned using four different beamlet sizes (1, 2, 5, and 10 mm) - in the leaf travel direction, while keeping the Y-dimension by multi-leaf collimator (MLC) width fixed, and compared to the reference plan with beamlet size of 3 mm. To evaluate the beamlet size effect, target volumes (coverage, conformity, and size effect), organ at risks (OARS) (doses to the spinal cord, lung and kidneys), and integral dose, and monitor units (MUs) were calculated. Results: Target coverage and dose conformity for planning target volume (PTV) were not correlated with beamlet size. Maximum (p = 0.000) and mean (p = 0.000) spinal cord doses decreased by 4.0% and 3.4% from 23.4% and 28.6% as beamlet size decreased from 10 to 1 mm. The integral doses, MUs and doses to other organs increased at smaller beamlet sizes. MUs for a beamlet size of 10 mm decreased by 31.4%, as compared with that at the reference beamlet size. Conclusions: Despite no dosimetric benefits with respect to target volume and an MU increase, a definite dose reduction was observed at the spinal cord for smaller beamlet sizes. Treatment with IMRS planning for the spine will benefit from the use of a beamlet size between 2 and 4 mm.

  4. SU-E-T-421: Feasibility Study of Volumetric Modulated Arc Therapy with Constant Dose Rate for Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, R; Wang, J [Peking University Third Hospital, Beijing, Beijing (China)

    2014-06-01

    Purpose: To investigate the feasibility, efficiency, and delivery accuracy of volumetric modulated arc therapy with constant dose rate (VMAT-CDR) for whole-pelvic radiotherapy (WPRT) of endometrial cancer. Methods: The nine-Field intensity-modulated radiotherapy (IMRT), VMAT with variable dose-rate (VMAT-VDR), and VMAT-CDR plans were created for 9 patients with endometrial cancer undergoing WPRT. The dose distribution of planning target volume (PTV), organs at risk (OARs), and normal tissue (NT) were compared. The monitor units (MUs) and treatment delivery time were also evaluated. For each VMAT-CDR plan, a dry Run was performed to assess the dosimetric accuracy with MatriXX from IBA. Results: Compared with IMRT, the VMAT-CDR plans delivered a slightly greater V20 of the bowel, bladder, pelvis bone, and NT, but significantly decreased the dose to the high-dose region of the rectum and pelvis bone. The MUs Decreased from 1105 with IMRT to 628 with VMAT-CDR. The delivery time also decreased from 9.5 to 3.2 minutes. The average gamma pass rate was 95.6% at the 3%/3 mm criteria with MatriXX pretreatment verification for 9 patients. Conclusion: VMAT-CDR can achieve comparable plan quality with significant shorter delivery time and smaller number of MUs compared with IMRT for patients with endometrial cancer undergoing WPRT. It can be accurately delivered and be an alternative to IMRT on the linear accelerator without VDR capability. This work is supported by the grant project, National Natural; Science Foundation of China (No. 81071237)

  5. Early gene expression divergence between allopatric populations of the house mouse (Mus musculus domesticus).

    Science.gov (United States)

    Bryk, Jarosław; Somel, Mehmet; Lorenc, Anna; Teschke, Meike

    2013-03-01

    Divergence of gene expression is known to contribute to the differentiation and separation of populations and species, although the dynamics of this process in early stages of population divergence remains unclear. We analyzed gene expression differences in three organs (brain, liver, and testis) between two natural populations of Mus musculus domesticus that have been separated for at most 3000 years. We used two different microarray platforms to corroborate the results at a large scale and identified hundreds of genes with significant expression differences between the populations. We find that although the three tissues have similar number of differentially expressed genes, brain and liver have more tissue-specific genes than testis. Most genes show changes in a single tissue only, even when expressed in all tissues, supporting the notion that tissue-specific enhancers act as separable targets of evolution. In terms of functional categories, in brain and to a smaller extent in liver, we find transcription factors and their targets to be particularly variable between populations, similar to previous findings in primates. Testis, however, has a different set of differently expressed genes, both with respect to functional categories and overall correlation with the other tissues, the latter indicating that gene expression divergence of potential importance might be present in other datasets where no differences in fraction of differentially expressed genes were reported. Our results show that a significant amount of gene expression divergence quickly accumulates between allopatric populations.

  6. On the Design of a Wireless Multi-antenna Monitoring System

    NARCIS (Netherlands)

    Hofstra, K.L.; Cronie, H.S.

    2004-01-01

    In this paper we investigate the design of a wireless monitoring system. This system consists of several wireless monitoring units, each transmitting data collected from sensors. This data is received and processed at a central control unit. The typical operating environment poses several

  7. The toxicity of brown algae (Sargassum sp extract to mice (Mus muscullus

    Directory of Open Access Journals (Sweden)

    Rahmat Wariz

    2016-08-01

    Full Text Available Indonesian is a country with very large and overflow marine biological resources. Utilization of seaweed has been developed and become a source of revenue for Indonesian who live in coastal areas with high potential for seaweed.The demand of seaweed in the world increases as increasing in the use of seaweed for various purposeamong others in the fields of industry, food, textile, paper, paints, cosmetics, medical and pharmaceutical field. Alginate is one of materials that commonly used in the field of dentistry as printed materials to create study models. Materials in the field of dentistry must be biocompatible to the oral cavity tissues. The materials should be stable, safe, comfortable, and certainly doesn’t have a toxicity character to the oral cavity tissues and other tissues in human body. The purpose of this study is to know the toxicity of extract brown algaeSargassum sp given orally to mice.The research perform experimental laboratory research type withexperimental post-tes-only control group design. The reseach samples applyfemales white mice (Mus muscullus. Research samples divided into 5 groups of 5 female mices for each treatment group. Treatment group 1 was given 500mg/kgBW doses of Sargassum sp, group 2 was given 1000mg/KgBW doses of Sargassum sp, group 3 was given 1500mg/KgBW doses of Sargassum sp, group 4 were 2000mg/KgBW doses of Sargassum sp, and a control group was given only dose of Na CMC. The result of this study isdose in humans are converted into 2000mg/KgBW in mice, is a doses that doesn’t cause the death of whole animals. Based of acute toxicity category, the extracts of Sargassum sp that obtained from Punaga Takalar Regency, South Sulawesi includes in the mild toxic.

  8. Radiation monitoring around United States nuclear test areas, calendar year 1989

    International Nuclear Information System (INIS)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs

  9. Radiation monitoring around United States nuclear test areas, calendar year 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    This report describes the Offsite Radiation Safety Program conducted during 1989 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory-Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels, and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether the testing is in compliance with existing radiation protection standards, and to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of both animals and humans. To implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any release of radioactivity, personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each test. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to NTS activities. Trends were evaluated in the Noble Gas and Tritium, Milk Surveillance, TLD, and PIC networks, and the Long-Term Hydrological Monitoring Program. 35 refs., 68 figs., 32 tabs.

  10. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1997

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency's (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods

  11. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1997

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency`s (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods.

  12. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    International Nuclear Information System (INIS)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G.

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency's (EPA's) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans

  13. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G. [and others

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans.

  14. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  15. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  16. Infrared system for monitoring movement of objects

    Science.gov (United States)

    Valentine, Kenneth H.; Falter, Diedre D.; Falter, Kelly G.

    1991-01-01

    A system for monitoring moving objects, such as the flight of honeybees and other insects, using a pulsed laser light source. This system has a self-powered micro-miniaturized transmitting unit powered, in the preferred embodiment, with an array solar cells. This transmitting unit is attached to the object to be monitored. These solar cells provide current to a storage energy capacitor to produce, for example, five volts for the operation of the transmitter. In the simplest embodiment, the voltage on the capacitor operates a pulse generator to provide a pulsed energizing signal to one or more very small laser diodes. The pulsed light is then received at a receiving base station using substantially standard means which converts the light to an electrical signal for processing in a microprocessor to create the information as to the movement of the object. In the case of a unit for monitoring honeybees and other insects, the transmitting unit weighs less than 50 mg, and has a size no larger than 1.times.3.times.5 millimeters. Also, the preferred embodiment provides for the coding of the light to uniquely identify the particular transmitting unit that is being monitored. A "wake-up" circuit is provided in the preferred embodiment whereby there is no transmission until the voltage on the capacitor has exceeded a pre-set threshold. Various other uses of the motion-detection system are described.

  17. FRAKSI ETANOL 96% BIJI KORO BENGUK (Mucuna pruriens L. SEBAGAI PENINGKAT KUALITAS SPERMATOZOA MENCIT (Mus musculus

    Directory of Open Access Journals (Sweden)

    Sri Winarni

    2012-11-01

    Full Text Available Background: The examination of sperm quality is the main priority for infertility diagnosis. Based on previous study with mice, active ingredient of Mucuna pruriens L. or koro benguk (Papilionaceae, the L-dopa, may affect the quality of spermatozoa.Objective: Research was to study the effect of 96% ethanol fraction Mucuna pruriens seed on spermatozoaquality of mice exposed to 2-Methoxy ethanol. L-dopa in 96% ethanol fraction of M. pruriens seed was 14.7%.Methode: This was an experimental study using complete randomized design. Subjects were BALB/C mice (Mus musculus. Five groups served as control, 3 groups received subcutaneos injection of 2-ME as muchas 100 mg/kg.bw/day for 12 days, followed with 96% ethanol fraction Mucuna pruriens seed starting from14 mg/kg.bw/day, 28 mg/kg.bw/day, and 56 mg/kg.bw/day for 51 days.Result: The 96% ethanol fraction of Mucuna pruriens seeds are significant increase motility (p<0,01 andthe percentage of normal spermatozoa morphology (p= 0,042.Conclusion: 96% ethanol fraction of Mucuna pruriens seeds are able to increase motility and the percentage of normal spermatozoa morphology in mice exposed to 2-ME. Keywords: Mucuna pruriens L., L-dopa, mouse spermatozoa

  18. Spermatogenic structure and fertility of Mus musculus after exposure of mangosteen (Garcinia mangostana L) pericarp extract

    Science.gov (United States)

    Hayati, Alfiah; Agustin, Melia Eka; Rokhimaningrum, Farida Ayu; Adro'i, Hasan; Darmanto, Win

    2016-03-01

    This study aimed to determine the effect of mangosteen (Garcinia mangostana L.) pericarp extract on spermatogenics number, seminiferous tubules sized, profile protein of epididymal and testicular sperm, and fertility of mice (Mus musculus). Fourty two male mice strain BALB/C was divided equally into 7 groups. The control group was given 0.05 ml of 0.05% CMC solution. Three group were given mangosteen pericarp extract at various doses (75, 100 and 150 mg/kg body weight, respectively) for 7 days, while the other three groups were given the same extract dose for 35 days. Parameters evaluated on histological of spermatogonia, spermatocytes, round spermatids, seminiferous tubule diameter, and thickness of germinal epithelium, analysis of testicular and epidydimal protein profile with SDS-Page, and than fertility test on female mice. The results showed that mangosteen pericarp extract at 75 and 100 mg/kg dose for 7 days had no effect on spermatogenics number and seminiferous tubule sizes, but the treatment dose of 150 mg/kg for 7 days and all treatment (doses of 75, 100, and 150 mg/kg) for 35 days led to significant decrease on the number of spermatogenics and seminiferous tubule sizes; effect on protein profiles testicular and epididymal sperm; and lower fertilization.

  19. Comment rester vigilant face à l’oubli ? Le musée de la fonderie à Rosières. How to remain vigilant against forgetting ? Rosières’s foundry museum.

    Directory of Open Access Journals (Sweden)

    Guillaume ETIENNE

    2011-12-01

    Full Text Available La mise en exposition d’objets liés au travail dépasse largement la simple présentation au public d’un savoir-faire ou d’une technique. Dans cette cité ouvrière du département du Cher, dans le centre de la France, les objets exposés au musée de la Fonderie semblent donner au visiteur bien plus qu’une vision générale du travail de la fonte. A travers l’analyse de la création de ce musée, de la mise en place d’un véritable réseau de vigilance contre la perte, et de l’exposition qui laisse transparaitre bien plus que des outils de travail, nous envisagerons ici le musée de la fonderie comme un microcosme d’une vie sociale aujourd’hui révolue, indissociable de l’usine et du paternalisme industriel qui a géré la vie des salariés pendant près d’un siècle et demi.More and more museums are dedicated to local histories of work and labour, displaying industrial artefacts and objects directly taken from the work place. In such museums, the visitors do not only get a chance to discover specific techniques and savoir-faire. The purpose is also to expose them to a much encompassing cultural experience. In the local museum of Rosières, a small industrial town located in the centre of France, the visitors are offered much more than the possibility to get a grasp of the smelting work itself, which we demonstrate through an analysis of the history of this museum, of the content of its permanent exhibition, and of a network of individuals who try to keep the industrial memory of this area alive. This museum indeed appears to function as a microcosm of a social life that no longer exists, and that was strongly connected to the factory life and the industrial plant as well as industrial paternalism that ruled the workers’ lives during almost one and a half century.

  20. Long-term dust climatology in the western United States reconstructed from routine aerosol ground monitoring

    Directory of Open Access Journals (Sweden)

    D. Q. Tong

    2012-06-01

    Full Text Available This study introduces an observation-based dust identification approach and applies it to reconstruct long-term dust climatology in the western United States. Long-term dust climatology is important for quantifying the effects of atmospheric aerosols on regional and global climate. Although many routine aerosol monitoring networks exist, it is often difficult to obtain dust records from these networks, because these monitors are either deployed far away from dust active regions (most likely collocated with dense population or contaminated by anthropogenic sources and other natural sources, such as wildfires and vegetation detritus. Here we propose an approach to identify local dust events relying solely on aerosol mass and composition from general-purpose aerosol measurements. Through analyzing the chemical and physical characteristics of aerosol observations during satellite-detected dust episodes, we select five indicators to be used to identify local dust records: (1 high PM10 concentrations; (2 low PM2.5/PM10 ratio; (3 higher concentrations and percentage of crustal elements; (4 lower percentage of anthropogenic pollutants; and (5 low enrichment factors of anthropogenic elements. After establishing these identification criteria, we conduct hierarchical cluster analysis for all validated aerosol measurement data over 68 IMPROVE sites in the western United States. A total of 182 local dust events were identified over 30 of the 68 locations from 2000 to 2007. These locations are either close to the four US Deserts, namely the Great Basin Desert, the Mojave Desert, the Sonoran Desert, and the Chihuahuan Desert, or in the high wind power region (Colorado. During the eight-year study period, the total number of dust events displays an interesting four-year activity cycle (one in 2000–2003 and the other in 2004–2007. The years of 2003, 2002 and 2007 are the three most active dust periods, with 46, 31 and 24

  1. PENGARUH DOSIS DAN LAMA PERLAKUAN EKSTRAK DAUN KALIANDRA MERAH (Calliandra calothyrsus Meissn. TERHADAP STRUKTUR HISTOLOGI GINJAL MENCIT (Mus musculus L.

    Directory of Open Access Journals (Sweden)

    Nur Assiam

    2014-09-01

    Full Text Available This research aims to determine the effect of red calliandra (Calliandra calothyrsusMeissn. leaf extrac on the histological structure of the kidney of mice (Mus musculus L..Treatment was administered orally with varying doses. This research used a CompletelyRandomized Design in factorial pattern of two factors, doses (0 or control, 2, 4, and 6 mg/kgBW and length of treatment (7, 14, and 21 days, so there are 12 combination groups with 3replications of each. Organ was collected on days 8, 15, and 22 to observe histologicalstructure of the kidney. Renal histological observation of edema, Bowman’s spaceconstriction, and protein deposition, showed no correlation between both factors, but a veryreal correlation occurs in the damage of fatty degeneration, hemorrhage, and nucleuspyknotic. Histological observation of glomerular congestion and infiltration of inflammatorycells did not show any correlation between dose and duration of treatment.Keywords: red calliandra, histopathology of kidney, male mice

  2. Pengaruh Lendir Bekicot (Achatina fulica terhadap Jumlah Sel Fibroblas pada Penyembuhan Luka Sayat Studi Eksperimental pada Kulit Mencit (Mus musculus

    Directory of Open Access Journals (Sweden)

    Perez Wahyu Purnasari

    2012-12-01

    Design and methods: The study is an experimental research with post test only randomized control group design. The subjects were 18 Mus musculus strain mice that were divided into 3 groups. 1st group as a control group of untreated, 2nd group was given povidone iodine 10%, and 3rd group was given land snails’ mucus during 5th days. On the 6th day the mices were killed for histological study. Results: The data showed that average number of fibroblast in 1st group is 93,85; 2nd group is 126,37; and 3rd is group 217,5. The results of one way anova statistical test showed significant difference among the three groups p = 0,000. The results of post hoc test showed significant difference in all groups (p < 0,05. Conclusion: The mucus of land snail is influence the number of fibroblast in healing cuts (Sains Medika, 4(2:195-203.

  3. EXAMINATION OF THE SUNGKAI’S YOUNG LEAF EXTRACT (Peronema canescens AS AN ANTIPIRETIC, IMMUNITY, ANTIPLASMODIUM AND TERATOGENITY IN MICE (Mus.muculus

    Directory of Open Access Journals (Sweden)

    Agus Martono Hadi Putranto

    2014-05-01

    Full Text Available The research of examination extract sungkai’s young leafs as an antipyretic, immunity, anti plasmodium and teratogenity in mice (Mus. Muculus has been done. The aims of this research is examinations in infusa effectiveness extract of the young leafs in mice (Mus. Muculus. The object of this research used 50 males Webster’s species mice has 7 – 8 week olds, averages 30 gram in weight. Mice are divided into 5 groups in examination for antipyretic. Mice has been introduced the DPT-HB fever before. The first group as a negative control treated a pure water, second group as a positive control treated a paracetamol 1.08 mg/Kg w/w and rest of groups treated a young sungkai’s extract leafs in the concentration of 0.186 mg/Kg w/w, 0.375 mg/Kg w/w and 0.5625 mg/Kg w/w respectively. Measurements of the temperature toke in the duration of 30, 60, 90 and 120 minutes. Furthermore, in the immunity examination, mice also divided into 5 groups, first as a negative control treated a pure water, second group as a positive control treated 0.07 mg/Kg imunos w/w and respectively for the rest groups treated with young sungkai’s extract leafs in the concentration of 0.186 mg/Kg w/w, 0.375 mg/Kg w/w and 0.5625 mg/Kg w/w. These treatments held in gavage system with the duration at 24 hours. In examination amount of the leukocyte number, toke from the tail of the mice, has a result the dosage in 0.5625 mg/Kg w/w extract’s young leafs of sungkai could be decrease the temperature 29%, it is better than paracetamol treatment which could be decreased only 26% of temperature. In addition, for the immunity examination, the best dosage of the young sungkai’s extract leafs is 0.567 mg/Kg w/w, which It can increase 36% amount of the leukocyte number. This dosage is better than the positive control by using Imunos, which is can increase only 23% of the temperature.

  4. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  5. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  6. Geothermal resource areas database for monitoring the progress of development in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, J.D.; Lepman, S.R.; Leung, K.; Phillips, S.L.

    1981-01-01

    The Geothermal Resource Areas Database (GRAD) and associated data system provide broad coverage of information on the development of geothermal resources in the United States. The system is designed to serve the information requirements of the National Progress Monitoring System. GRAD covers development from the initial exploratory phase through plant construction and operation. Emphasis is on actual facts or events rather than projections and scenarios. The selection and organization of data are based on a model of geothermal development. Subjects in GRAD include: names and addresses, leases, area descriptions, geothermal wells, power plants, direct use facilities, and environmental and regulatory aspects of development. Data collected in the various subject areas are critically evaluated, and then entered into an on-line interactive computer system. The system is publically available for retrieval and use. The background of the project, conceptual development, software development, and data collection are described here. Appendices describe the structure of the database in detail.

  7. DUCKS: Low cost thermal monitoring units for near-vent deployment

    Science.gov (United States)

    Harris, Andrew; Pirie, Dawn; Horton, Keith; Garbeil, Harold; Pilger, Eric; Ramm, Hans; Hoblitt, Rick; Thornber, Carl; Ripepe, Maurizio; Marchetti, Emanuele; Poggi, Pasquale

    2005-05-01

    During 1999 we designed and tested a thermal monitoring system to provide a cheap, robust, modular, real-time system capable of surviving the hostile conditions encountered proximal to active volcanic vents. In November 2000 the first system was deployed at Pu'u 'O'o (Kilauea, Hawai'i) to target persistently active vents. Aside from some minor problems, such as sensor damage due to tampering, this system remained operational until January 2004. The success of the prototype system led us to use the blueprint for a second installation at Stromboli (Aeolian Islands, Italy). This was deployed, dug into a bomb-proof bunker, during May 2002 and survived the April 2003 paroxysmal eruption despite being located just 250 m from the vent. In both cases, careful waterproofing of connectors and selection of suitable protection has prevented water damage and corrosion in the harsh atmosphere encountered at the crater rim. The Pu'u 'O'o system cost ˜US10,000 and comprises four modules: sensors, transmission and power hub, repeater station and reception site. The sensor component consists of three thermal infrared thermometers housed in Pelican™ cases fitted with Germanium-Arsenide-Selenium windows. Two 1° field of view (FOV) sensors allow specific vents to be targeted and a 60° FOV sensor provides a crater floor overview. A hard wire connection links to a Pelican™-case-housed microprocessor, modem and power module. From here data are transmitted, via a repeater site, to a dedicated PC at the Hawaiian Volcano Observatory. Here data are displayed with a delay of ˜3 s between acquisition and display. The modular design allows for great flexibility. At Stromboli, 1° and 15° FOV sensor modules can be switched depending changes in activity style and crater geometry. In addition a direct line of site to the Stromboli reception center negates the repeater site requirement, reducing the cost to US5500 for a single sensor system. We have also constructed self-contained units

  8. DUCKS: Low cost thermal monitoring units for near-vent deployment

    Science.gov (United States)

    Harris, A.; Pirie, D.; Horton, K.; Garbeil, H.; Pilger, E.; Ramm, H.; Hoblitt, R.; Thornber, C.; Ripepe, M.; Marchetti, E.; Poggi, P.

    2005-01-01

    During 1999 we designed and tested a thermal monitoring system to provide a cheap, robust, modular, real-time system capable of surviving the hostile conditions encountered proximal to active volcanic vents. In November 2000 the first system was deployed at Pu'u 'O'o (Kilauea, Hawai'i) to target persistently active vents. Aside from some minor problems, such as sensor damage due to tampering, this system remained operational until January 2004. The success of the prototype system led us to use the blueprint for a second installation at Stromboli (Aeolian Islands, Italy). This was deployed, dug into a bomb-proof bunker, during May 2002 and survived the April 2003 paroxysmal eruption despite being located just 250 m from the vent. In both cases, careful waterproofing of connectors and selection of suitable protection has prevented water damage and corrosion in the harsh atmosphere encountered at the crater rim. The Pu'u 'O'o system cost ???US$10,000 and comprises four modules: sensors, transmission and power hub, repeater station and reception site. The sensor component consists of three thermal infrared thermometers housed in Pelican??? cases fitted with Germanium-Arsenide-Selenium windows. Two 1?? field of view (FOV) sensors allow specific vents to be targeted and a 60?? FOV sensor provides a crater floor overview. A hard wire connection links to a Pelican???-case-housed microprocessor, modem and power module. From here data are transmitted, via a repeater site, to a dedicated PC at the Hawaiian Volcano Observatory. Here data are displayed with a delay of ???3 s between acquisition and display. The modular design allows for great flexibility. At Stromboli, 1?? and 15?? FOV sensor modules can be switched depending changes in activity style and crater geometry. In addition a direct line of site to the Stromboli reception center negates the repeater site requirement, reducing the cost to US$5500 for a single sensor system. We have also constructed self-contained units

  9. Power consumption monitoring using additional monitoring device

    Energy Technology Data Exchange (ETDEWEB)

    Truşcă, M. R. C., E-mail: radu.trusca@itim-cj.ro; Albert, Ş., E-mail: radu.trusca@itim-cj.ro; Tudoran, C., E-mail: radu.trusca@itim-cj.ro; Soran, M. L., E-mail: radu.trusca@itim-cj.ro; Fărcaş, F., E-mail: radu.trusca@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Abrudean, M. [Technical University of Cluj-Napoca, Cluj-Napoca (Romania)

    2013-11-13

    Today, emphasis is placed on reducing power consumption. Computers are large consumers; therefore it is important to know the total consumption of computing systems. Since their optimal functioning requires quite strict environmental conditions, without much variation in temperature and humidity, reducing energy consumption cannot be made without monitoring environmental parameters. Thus, the present work uses a multifunctional electric meter UPT 210 for power consumption monitoring. Two applications were developed: software which carries meter readings provided by electronic and programming facilitates remote device and a device for temperature monitoring and control. Following temperature variations that occur both in the cooling system, as well as the ambient, can reduce energy consumption. For this purpose, some air conditioning units or some computers are stopped in different time slots. These intervals were set so that the economy is high, but the work's Datacenter is not disturbed.

  10. Use of Internet Search Data to Monitor Rotavirus Vaccine Impact in the United States, United Kingdom, and Mexico.

    Science.gov (United States)

    Shah, Minesh P; Lopman, Benjamin A; Tate, Jacqueline E; Harris, John; Esparza-Aguilar, Marcelino; Sanchez-Uribe, Edgar; Richardson, Vesta; Steiner, Claudia A; Parashar, Umesh D

    2018-02-19

    Previous studies have found a strong correlation between internet search and public health surveillance data. Less is known about how search data respond to public health interventions, such as vaccination, and the consistency of responses in different countries. In this study, we aimed to study the correlation between internet searches for "rotavirus" and rotavirus disease activity in the United States, United Kingdom, and Mexico before and after introduction of rotavirus vaccine. We compared time series of internet searches for "rotavirus" from Google Trends with rotavirus laboratory reports from the United States and United Kingdom and with hospitalizations for acute gastroenteritis in the United States and Mexico. Using time and location parameters, Google quantifies an internet query share (IQS) to measure the relative search volume for specific terms. We analyzed the correlation between IQS and laboratory and hospitalization data before and after national vaccine introductions. There was a strong positive correlation between the rotavirus IQS and laboratory reports in the United States (R2 = 0.79) and United Kingdom (R2 = 0.60) and between the rotavirus IQS and acute gastroenteritis hospitalizations in the United States (R2 = 0.87) and Mexico (R2 = 0.69) (P United States and by 70% (95% CI, 55%-86%) in Mexico. In the United Kingdom, there was a loss of seasonal variation after vaccine introduction. Rotavirus internet search data trends mirrored national rotavirus laboratory trends in the United States and United Kingdom and gastroenteritis-hospitalization data in the United States and Mexico; lower correlations were found after rotavirus vaccine introduction. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  11. Mitochondrial Genetic Diversity and Phylogeography of Mus musculus castaneus in Northern Punjab, Pakistan.

    Science.gov (United States)

    Bibi, Shahnaz; Nadeem, Muhammad Sajid; Wiewel, Andrew Stephen; Beg, Mirza Azhar; Hameed, Khalid; Jabeen, Musarrat; Raja, Ghazala Kaukab

    2017-12-01

    Regions of Iran, Afghanistan, Pakistan and northwestern India have been proposed as the place of origin of Mus musculus castaneus. But despite the fact that Pakistan encompasses an important part of its range, M. m. castaneus populations in Pakistan have not been the subject of intensive genetic and biogeographic studies, except for a very small number of samples included in past studies. We studied genetic variation in M. m. castaneus (CAS) from northern Punjab Province, Pakistan, by using cytochrome b (Cytb) analysis in a sample of 98 individuals. Median-joining network revealed four well differentiated CAS sub-lineages coexisting within a small geographical region; these had previously been thought to have largely non-overlapping geographic distributions. Moreover, haplotypes from Pakistan occupied a central position in the network and all identified global haplotypes were also present in Pakistan. All identified CAS sub-lineages proved to be highly diverse on the basis of haplotype and nucleotide diversity indices. Tajima's D test and Fu's Fs tests of neutrality suggest recent population expansions in all sub-lineages. Expansion times were estimated as 21,760-134,930, 10,800-64,400 and 4950-30,665 ybp using substitution rates of 2.5%, 5% and 11%, respectively. Our results support the hypothesis that northern Punjab Province in Pakistan is the most likely source area for M. m. castaneus, and that the CAS sub-lineages in this region have undergone rapid population expansion events at different time periods, which appear to have benefitted from human-mediated transport, although one of them clearly predates the establishment of human settlements in this region.

  12. Technology monitoring in the CIEMAT; La vigilancia tecnologica en el CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Martinez, M.; Cuesta, M. J.; Crespi, S. N.; Cabrera, J. A.

    2008-07-01

    The CIEMAT Foresight and Technology Monitoring Unit focuses its activities on obtaining strategic information on future developments in the area of energy and environment that can be used for decision making by the centers management. In addition, it provides services to CIEMAT researchers and other external customers. In May 2007, the Asociacion Espanola de Normalizacion y Certificacion AENOR delivered to the CIEMAT the first Technology Monitoring System certificate granted in Spain as per standard UNE 166006:2006. This article describes the Units experience in the implementation process of the Technology Monitoring System and provides several examples of the way in which the Unit graphically represents the information analyzed in its Technology Monitoring Reports. (Author)

  13. Material monitoring

    International Nuclear Information System (INIS)

    Kotter, W.; Zirker, L.; Hancock, J.A.

    1995-01-01

    Waste Reduction Operations Complex (WROC) facilities are located at the Idaho National Engineering Laboratory (INEL). The overall goal for the Pollution Prevention/Waste Minimization Unit is to identify and establish the correct amount of waste generated so that it can be reduced. Quarterly, the INEL Pollution Prevention (P2) Unit compares the projected amount of waste generated per process with the actual amount generated. Examples of waste streams that would be addresses for our facility would include be are not limited to: Maintenance, Upgrades, Office and Scrap Metal. There are three potential sources of this variance: inaccurate identification of those who generate the waste; inaccurate identification of the process that generates the waste; and inaccurate measurement of the actual amount generated. The Materials Monitoring Program was proposed to identify the sources of variance and reduce the variance to an acceptable level. Prior to the implementation of the Material Monitoring Program, all information that was gathered and recorded was done so through an informal estimation of waste generated by various personnel concerned with each processes. Due to the inaccuracy of the prior information gathering system, the Material Monitoring Program was established. The heart of this program consists of two main parts. In the first part potential waste generators provide information on projected waste generation process. In the second part, Maintenance, Office, Scrap Metal and Facility Upgrade wastes from given processes is disposed within the appropriate bin dedicated to that process. The Material Monitoring Program allows for the more accurate gathering of information on the various waste types that are being generated quarterly

  14. Characterizing the Breadth and Depth of Volunteer Water Monitoring Programs in the United States

    Science.gov (United States)

    Stepenuck, Kristine F.; Genskow, Kenneth D.

    2018-01-01

    A survey of 345 volunteer water monitoring programs in the United States was conducted to document their characteristics, and perceived level of support for data to inform natural resource management or policy decisions. The response rate of 86% provided information from 46 states. Programs represented a range of ages, budgets, objectives, scopes, and level of quality assurance, which influenced data uses and perceived support by sponsoring agency administrators and external decision makers. Most programs focused on rivers, streams, and lakes. Programs had not made substantial progress to develop EPA or state-approved quality assurance plans since 1998, with only 48% reporting such plans. Program coordinators reported feeling slightly more support for data to be used for management as compared to policy decisions. Programs with smaller budgets may be at particular risk of being perceived to lack credibility due to failure to develop quality assurance plans. Over half of programs identified as collaborative, in that volunteers assisted scientists in program design, data analysis and/or dissemination of results. Just under a third were contributory, in which volunteers primarily collected data in a scientist-defined program. Recommendations to improve perceived data credibility, and to augment limited budgets include developing quality assurance plans and gaining agency approval, and developing partnerships with other organizations conducting monitoring in the area to share resources and knowledge. Funding agencies should support development of quality assurance plans to help ensure data credibility. Service providers can aid in plan development by providing training to program staff over time to address high staff turnover rates.

  15. Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period.

    Science.gov (United States)

    Helder, Onno K; van Goudoever, Johannes B; Hop, Wim C J; Brug, Johannes; Kornelisse, René F

    2012-10-08

    Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to determine compliance with hand hygiene protocols by direct observation. A one-year observational study was conducted at a 27 bed level III NICU at a university hospital. All healthcare workers employed at the NICU participated in the study. The use of bedside dispensers was continuously monitored and compliance with hand hygiene was determined by random direct observations. A total of 258,436 hand disinfection events were recorded; i.e. a median (interquartile range) of 697 (559-840) per day. The median (interquartile range) number of hand disinfection events performed per healthcare worker during the day, evening, and night shifts was 13.5 (10.8 - 16.7), 19.8 (16.3 - 24.1), and 16.6 (14.2 - 19.3), respectively. In 65.8% of the 1,168 observations of patient contacts requiring hand hygiene, healthcare workers fully complied with the protocol. We conclude that the electronic devices provide useful information on frequency, time, and location of its use, and also reveal trends in hand disinfection events over time. Direct observations offer essential data on compliance with the hand hygiene protocol. In future research, data generated by the electronic devices can be supplementary used to evaluate the effectiveness of hand hygiene promotion campaigns.

  16. Solid Waste Management Units And Areas Of Concern Annual Long-Term Monitoring & Maintenance Report For Calendar Year 2016.

    Energy Technology Data Exchange (ETDEWEB)

    Dotson, Patrick Wells [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Little, Bonnie Colleen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    Long-term controls were maintained at 21 Solid Waste Management Units (SWMUs) and Areas of Concern (AOCs) in accordance with the requirements of the “Long-Term Monitoring and Maintenance Plan for SWMUs and AOCs Granted Corrective Action Complete with Controls” in Attachment M of the Resource Conservation and Recovery Act Facility Operating Permit, which took effect February 26, 2015. Maintenance and controls at these SWMUs and AOCs are described and documented in this report. Conditions requiring maintenance or repair activities were not identified for any of the inspected SWMUs or AOCs. Based upon the inspections performed and site conditions observed, the administrative and physical institutional controls in place at the SWMUs and AOCs are effectively providing continued protection of human health and the environment. This report does not present monitoring and maintenance activities for SWMU 76, the Mixed Waste Landfill; those activities adhere to the approved MWL LTMM Plan, Section 4.8.1 requiring a separate annual report which will be submitted to the NMED by June 30, 2017.

  17. 40 CFR 60.49Da - Emission monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Emission monitoring. 60.49Da Section 60... Generating Units for Which Construction is Commenced After September 18, 1978 § 60.49Da Emission monitoring...). (2) As an alternative to the monitoring requirements in paragraph (a)(1) of this section, an owner or...

  18. The development of web monitoring digital area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su

    2005-01-01

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system

  19. The development of web monitoring digital area monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su [Iljin Radiation Engineering Co., Seoul (Korea, Republic of)

    2005-11-15

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system.

  20. Radioisotope dust pollution monitor

    International Nuclear Information System (INIS)

    Szepke, R.; Harasimczuk, J.; Dobrowiecki, J.

    1990-01-01

    Measuring principles and specification of two dust monitors: station-type AMIZ and portable-type PIK-10 for ambient air pollution are presented. The first one, a fully automatic instrument is destined for permanent monitoring of air pollution in preset sampling time from .25 to 24 hours. The second one was developed as a portable working model. Both instruments display their results in digital form in dust concentration units. (author)

  1. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Newcomer, D.R.; Thornton, E.C.; Hartman, M.J.; Dresel, P.E.

    1999-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954 the Resource Conservation and Recovery Act of 1976 the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The US Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/frequency matrix for the entire site. The objectives of monitoring fall into three general categories plume and trend tracking, treatment/storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  2. EDGAR, a new plant radiation monitoring system

    International Nuclear Information System (INIS)

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  3. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    International Nuclear Information System (INIS)

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  4. Wireless air monitoring network with new AMIZ-2004G dust monitors

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Machaj, B.; Pienkos, P.; Swistowski, E.

    2006-01-01

    The principle of operation of the dust monitors is based on determination of dust mass deposited on air filters from known volumes of air samples. The dust mass is determined from radiation attenuation of a Pm-147 beta source. MIZA and AMIZ monitors produced in the Institute of Nuclear Chemistry and Technology, Warsaw (Poland) additionally measure relative humidity, atmospheric pressure and temperature of the air. In case the measurements are made in a few different places, direct collection of the results requires that personnel of the environment protection units has to go frequently to the monitors and collect the data. To improve the data transmission, a new version of the AMIZ-2004G monitor was developed which is equipped with a GSM modem enabling communication with a central computer. Thanks to the new construction not only a remote wireless communication with AMIZ is possible, but also a monitoring network containing a higher number of dust monitors can be made. The measuring data from all the monitors in the network can now be collected in one central computer equipped with the GSM modem and a proper acquisition program. In 2005, two such monitoring networks were put into operation

  5. Experience with neutron flux monitoring systems qualified for post-accident monitoring

    International Nuclear Information System (INIS)

    Shugars, H.G.; Miller, J.F.

    1995-01-01

    In this paper we discuss the environmental requirements for excore neutron flux monitors that are qualified for use during and after postulated accidents in Pressurized Water Reactors (PWRs). We emphasize PWRs designed in the United States, which are similar to those used also in parts of Western Europe and Eastern Asia. We then discuss design features of the flux monitoring systems necessary to address the environmental, functional, and regulatory requirements, and the experience with these systems. (author). 9 refs, 2 figs

  6. Les Cabinets de curiosités dauphinois dans les origines scientifiques du Muséum d'histoire naturelle de Grenoble (XVIII e -XIX e siècles)

    OpenAIRE

    Rochas , Joëlle

    2008-01-01

    Les actes du colloque de Poitiers concernant les cabinets de curiosités seront déposés sur le site web www.curiositas.org, site européen dédié aux cabinets de curiosités (Université de Poitiers).; Le Cabinet d'histoire naturelle de Grenoble, ancêtre du Muséum actuel, a été créé en 1773. Un premier historique de la fin du XVIIIe siècle mentionne les trois principaux cabinets d'où il était issu : un cabinet dauphinois - celui des Antonins - et deux cabinets grenoblois - celui du négociant greno...

  7. F-Area Seepage Basins groundwater monitoring report

    International Nuclear Information System (INIS)

    1992-09-01

    This progress report from the Savannah River Plant for second quarter 1992 includes discussion on the following topics: description of facilities; hydrostratigraphic units; monitoring well nomenclature; integrity of the monitoring well network; groundwater monitoring data; analytical results exceeding standards; tritium, nitrate, and pH time-trend data; water levels; groundwater flow rates and directions; upgradient versus downgradient results

  8. F-Area Seepage Basins groundwater monitoring report

    International Nuclear Information System (INIS)

    1992-06-01

    This progress report from the Savannah River Plant for first quarter 1992 includes discussion on the following topics: description of facilities; hydrostratigraphic units; monitoring well nomenclature; integrity of the monitoring well network; groundwater monitoring data; analytical results exceeding standards; tritium, nitrate, and pH time-trend data; water levels; groundwater flow rates and directions; upgradient versus downgradient results

  9. Interspecies Variation in the Susceptibility of a Wild-Derived Colony of Mice to Pinworms (Aspiculuris tetraptera).

    Science.gov (United States)

    Curtis, Ryan C; Murray, Jill K; Campbell, Polly; Nagamori, Yoko; Molnar, Adam; Jackson, Todd A

    2017-01-01

    Pinworms are common parasites in wild and laboratory rodents. Despite their relative nonpathogenicity in immunocompetent models, pinworm infections add an unwanted variable and may confound some types of research. For this reason, health monitoring programs and biosecurity measures aim to minimize the spread of pinworm infections into colonies free from the organisms. Wild-derived and laboratory strains of mice have shown varied susceptibility to infection with Aspiculuris tetraptera, the most commonly found murine pinworm. In particular, susceptibility is increased in wild-derived mice, young animals, and males. Routine surveillance at our institution revealed pinworm infection (A. tetraptera only) within a colony of multiple, wild-derived species of Mus, although only specific species showed positive results during initial sampling. To assess whether species-associated differences in susceptibility were present, we analyzed fecal egg counts of A. tetraptera in every cage of the colony. Our results revealed significant differences in susceptibility between various species and subspecies of Mus. Egg counts were significantly higher in Mus spicilegus than Mus m. domesticus (WSB/EiJ) and Mus macedonicus. Mus spretus had higher egg counts than M. m. domesticus (WSB/EiJ), M. m. musculus (PWK/PhJ), and M. macedonicus. Egg counts did not differ in regard to age, sex, or number of mice per cage. As wild-derived mouse models continue to compliment research largely based on laboratory strains, it will be important to understand host-parasite interactions and their effects on research, particularly studies evaluating immune responses, behavior, growth, and other physiologic parameters.

  10. 40 CFR 160.35 - Quality assurance unit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Quality assurance unit. 160.35 Section... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for monitoring each study to assure...

  11. Shutdown risk monitoring in TEPCO

    International Nuclear Information System (INIS)

    Sato, Hiroki; Masuda, Takahiro; Denda, Yasutaka; Yoneyama, Mitsuru; Imai, Shun-ichi; Miyata, Koichi

    2009-01-01

    At present, we are introducing risk monitors into our all three nuclear power stations; Fukushima Daiichi, Fukushima Daini and Kashiwazaki Kariwa, with technical support of TEPSYS. By monitoring shutdown risk of each unit, we are trying to optimize risks during outage inspection, and raising staff's awareness for reactor safety. This paper presents our recent shutdown risk monitoring activities in Fukushima Daiichi NPS. Shutdown risk monitoring has been carried out for the past five outages of Fukushima Daiichi NPS. Daily-changing shutdown risk is evaluated in the form of core damage frequency (CDF [/day/reactor]). We also examine high-risk point of outage plan if CDF is greater than the threshold at anytime of outage. The results are delivered to operational and maintenance staff before outage. The threshold value is set ten times as much as CDF of unit in operation. As CDF exceeds the threshold, we try to either change the system configuration, or let workers pay more attention to their works during the high-risk period. We already have some examples of outage plan modification to reduce CDF using the risk monitoring information. Greater number of station staff tends to pay more attention to shutdown risk thanks to these activities. (author)

  12. Electronic device, system on chip and method for monitoring a data flow

    NARCIS (Netherlands)

    2012-01-01

    An electronic device is provided which comprises a plurality of processing units (IP1-IP6), a network-based inter-connect (N) coupled to the processing units (IP1-IP6) and at least one monitoring unit (P1, P2) for monitoring a data flow of at least one first communication path between the processing

  13. A radiation monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  14. Development and installation of a new on-line plant safety monitoring system for the Paks VVER-440 units

    International Nuclear Information System (INIS)

    Vegh, J.; Major, C.; Buerger, L.; Lipcsei, S.; Horvath, C.; Kapocs, G.; Eiler, J.; Hornaes, A.; Hulsund, J.E.

    2000-01-01

    The paper describes the architecture, modules, algorithms and human-machine interface of a new operator support system (OSS), which is integrated into the new, reconstructed Paks NPP plant computers. The main task of the new OSS is to perform continuous plant safety monitoring and assessment, it has the following basic functions: on-line evaluation and presentation of critical safety function (CSF) status trees, continuous evaluation and presentation of the actual safety status of the plant, displaying and browsing the new symptom-oriented EOPs, automatic displaying of those process signals which are quoted in the EOPs. The first version of the new operator support system was connected to the Paks NPP full scope simulator in October 1999. This configuration was later successfully applied for the simulator testing of the new symptom-oriented EOP set for the Paks NPP in November 1999. The installation process was continued in 2000: the new system started its operation on Unit 2 (June) and on Unit 1 (August), together with the reconstructed, new PCS. (author)

  15. Tissue-Specific Contributions of Paternally Expressed Gene 3 in Lactation and Maternal Care of Mus musculus.

    Directory of Open Access Journals (Sweden)

    Wesley D Frey

    Full Text Available Paternally Expressed Gene 3 (Peg3 is an imprinted gene that controls milk letdown and maternal-caring behaviors. In this study, a conditional knockout allele has been developed in Mus musculus to further characterize these known functions of Peg3 in a tissue-specific manner. The mutant line was first crossed with a germline Cre. The progeny of this cross displayed growth retardation phenotypes. This is consistent with those seen in the previous mutant lines of Peg3, confirming the usefulness of the new mutant allele. The mutant line was subsequently crossed individually with MMTV- and Nkx2.1-Cre lines to test Peg3's roles in the mammary gland and hypothalamus, respectively. According to the results, the milk letdown process was impaired in the nursing females with the Peg3 mutation in the mammary gland, but not in the hypothalamus. This suggests that Peg3's roles in the milk letdown process are more critical in the mammary gland than in the hypothalamus. In contrast, one of the maternal-caring behaviors, nest-building, was interrupted in the females with the mutation in both MMTV- and Nkx2.1-driven lines. Overall, this is the first study to introduce a conditional knockout allele of Peg3 and to further dissect its contribution to mammalian reproduction in a tissue-specific manner.

  16. SU-E-T-125: Application of Jaw-Tracking Function in VMAT for Upper Thoracic Esophageal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W; Chen, J; Zhai, T; Yan, L; Chen, C [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To explore the effect of the Jaw-tracking with RapidArc(JT-RapidArc) plans for upper thoracic esophageal cancer. Methods: Treatment planning was designed by using RapidArc and JT-RapidArc techniques for 11 consecutive patients. The dose-volume histogram parameters of PTV and the organs at risk(OAR), conformity index(CI), heterogeneity index(HI), low dose volume of normal tissue(B-P) and monitor units(MUs) were compared between the different techniques. Results: JT-RapidArc plans provided the better coverage of PTV1(64) D98 and HI(P<0.05), lower MLD, D2 of PTV1(64) and PTV2(54), but no statistically difference in CI(P>0.05), which comparison with RapidArc plans. Plans with JT- RapidArc had lower Lung of V5, V10, V13, V20, V30, MLD(P<0.05); heart of V20, MLD(P<0.05); and B-P of V5, V10, V15, V20, V30(P<0.05); but no significantly different in Spinal cord and SC-PRV as compared with RapidArc plans. JT-RapidArc plans increaseed the MUs by 1%(P>0.05) as compared with RapidArc plans. Conclusion: All of the plans had met the requirements of clinical dosimetry. JT-RapidArc plans as compared with RapidArc plans, showing better part of target coverage, part of OARS(lung and heart) and heart and B-P sparing, which MUs was slightly increased. This work was sponsored by Shantou University Medical College Clinical Research Enhancement Initiative(NO.201424)

  17. A comparison of volumetric modulated arc therapy and sliding-window intensity-modulated radiotherapy in the treatment of Stage I-II nasal natural killer/T-cell lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xianfeng [Department of Radiation Oncology, Chongqing Cancer Institute, Chongqing (China); Yang, Yong [Department of Radiation Oncology, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Jin, Fu; He, Yanan; Zhong, Mingsong; Luo, Huanli; Qiu, Da; Li, Chao; Yang, Han; He, Guanglei [Department of Radiation Oncology, Chongqing Cancer Institute, Chongqing (China); Wang, Ying, E-mail: zjajf@126.com [Department of Radiation Oncology, Chongqing Cancer Institute, Chongqing (China)

    2016-04-01

    This article is aimed to compare the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for Stage I-II nasal natural killer/T-cell lymphoma (NNKTL). Ten patients with Stage I-II NNKTL treated with IMRT were replanned with VMAT (2 arcs). The prescribed dose of the planning target volume (PTV) was 50 Gy in 25 fractions. The VMAT plans with the Anisotropic Analytical Algorithm (Version 8.6.15) were based on an Eclipse treatment planning system; the monitor units (MUs) and treatment time (T) were scored to measure the expected treatment efficiency. All the 10 patients under the study were subject to comparisons regarding the quality of target coverage, the efficiency of delivery, and the exposure of normal adjacent organs at risk (OARs). The study shows that VMAT was associated with a better conformal index (CI) and homogeneity index (HI) (both p < 0.05) but slightly higher dose to OARs than IMRT. The MUs with VMAT (650.80 ± 24.59) were fewer than with IMRT (1300.10 ± 57.12) (relative reduction of 49.94%, p = 0.00) when using 2-Gy dose fractions. The treatment time with VMAT (3.20 ± 0.02 minutes) was shorter than with IMRT (7.38 ± 0.18 minutes) (relative reduction of 56.64%, p = 0.00). We found that VMAT and IMRT both provide satisfactory target dosimetric coverage and OARs sparing clinically. Likely to deliver a bit higher dose to OARs, VMAT in comparison with IMRT, is still a better choice for treatment of patients with Stage I-II NNKTL, thanks to better dose distribution, fewer MUs, and shorter delivery time.

  18. Remote Monitoring Transparency Program

    International Nuclear Information System (INIS)

    Sukhoruchkin, V.K.; Shmelev, V.M.; Roumiantsev, A.N.

    1996-01-01

    The objective of the Remote Monitoring Transparency Program is to evaluate and demonstrate the use of remote monitoring technologies to advance nonproliferation and transparency efforts that are currently being developed by Russia and the United States without compromising the national security to the participating parties. Under a lab-to-lab transparency contract between Sandia National Laboratories (SNL) and the Kurchatov Institute (KI RRC), the Kurchatov Institute will analyze technical and procedural aspects of the application of remote monitoring as a transparency measure to monitor inventories of direct- use HEU and plutonium (e.g., material recovered from dismantled nuclear weapons). A goal of this program is to assist a broad range of political and technical experts in learning more about remote monitoring technologies that could be used to implement nonproliferation, arms control, and other security and confidence building measures. Specifically, this program will: (1) begin integrating Russian technologies into remote monitoring systems; (2) develop remote monitoring procedures that will assist in the application of remote monitoring techniques to monitor inventories of HEU and Pu from dismantled nuclear weapons; and (3) conduct a workshop to review remote monitoring fundamentals, demonstrate an integrated US/Russian remote monitoring system, and discuss the impacts that remote monitoring will have on the national security of participating countries

  19. Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tobler, Matt; Leavitt, Dennis D.; Watson, Gordon

    2004-01-01

    Advances in field-shaping techniques for stereotactic radiosurgery/radiotherapy have allowed dynamic adjustment of field shape with gantry rotation (dynamic conformal arc) in an effort to minimize dose to critical structures. Recent work evaluated the potential for increased sparing of dose to normal tissues when the primary collimator setting is optimized to only the size necessary to cover the largest shape of the dynamic micro multi leaf field. Intensity-modulated radiotherapy (IMRT) is now a treatment option for patients receiving stereotactic radiotherapy treatments. This multisegmentation of the dose delivered through multiple fixed treatment fields provides for delivery of uniform dose to the tumor volume while allowing sparing of critical structures, particularly for patients whose tumor volumes are less suited for rotational treatment. For these segmented fields, the total number of monitor units (MUs) delivered may be much greater than the number of MUs required if dose delivery occurred through an unmodulated treatment field. As a result, undesired dose delivered, as leakage through the leaves to tissues outside the area of interest, will be proportionally increased. This work will evaluate the role of optimization of the primary collimator setting for these IMRT treatment fields, and compare these results to treatment fields where the primary collimator settings have not been optimized

  20. Structural shielding design of a 6 MV flattening filter free linear accelerator: Indian scenario

    Directory of Open Access Journals (Sweden)

    Bibekananda Mishra

    2017-01-01

    Full Text Available Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC operated with flattening filter (FF and flattening filter free (FFF modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP Report No. 151 and the other based on the monitor units (MUs delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  1. Working paper on monitoring strategies in the United Kingdom, Federal Republic of Germany and United States of America

    NARCIS (Netherlands)

    Buring, E.; Lanting, R.

    1989-01-01

    This study is a working paper on monitoring strategies used in the U.K., the FRG and the USA to assess exposure to airborne chemical substances. After a brief description of the basic philosophy on monitoring strategies, the requirements formonitoring from the different legal systems in the three

  2. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Hartman, Mary J.; Dresel, P. Evan; Lindberg, Jon W.; Newcomer, Darrell R.; Thornton, Edward C.

    2000-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954; the Resource Conservation and Recovery Act of 1976; the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The U.S. Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/ frequency matrix for the entire site. The objectives of monitoring fall into three general categories: plume and trend tracking, treatment/ storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  3. Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Revision 1

    International Nuclear Information System (INIS)

    1994-01-01

    This report describes environmental monitoring activities at Hanford Reservation. Attention is focused on effluent monitoring and environmental surveillance. All Hanford contractors reviewed potential sources of contamination. A facility effluent monitoring plan was written for each facility with the potential to release significant quantities of hazardous materials, addressing both radiological and nonradiological effluent monitoring. The environmental surveillance program assesses onsite and offsite environmental impacts and offsite human health exposures. The program monitors air, surface water, sediment, agricultural products, vegetation, soil, and wildlife. In addition, independent onsite surveillance is conducted to evaluate the effectiveness of Hanford Site effluent controls in order to comply with applicable environmental standards and regulations

  4. Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-11-09

    This report describes environmental monitoring activities at Hanford Reservation. Attention is focused on effluent monitoring and environmental surveillance. All Hanford contractors reviewed potential sources of contamination. A facility effluent monitoring plan was written for each facility with the potential to release significant quantities of hazardous materials, addressing both radiological and nonradiological effluent monitoring. The environmental surveillance program assesses onsite and offsite environmental impacts and offsite human health exposures. The program monitors air, surface water, sediment, agricultural products, vegetation, soil, and wildlife. In addition, independent onsite surveillance is conducted to evaluate the effectiveness of Hanford Site effluent controls in order to comply with applicable environmental standards and regulations.

  5. Design and Implementation of the Intensive Care Unit Quality Management Registry: Monitoring Quality and Cost of an Adult Intensive Care Unit in a Greek State Hospital.

    Science.gov (United States)

    Kosmidis, Dimitrios; Koutsouki, Sotiria; Lampiri, Klairi; Nagy, Eva Ottilia; Papaioannou, Vasilios; Pneumatikos, Ioannis; Anastassopoulos, George

    2017-11-01

    Intensive care electronic registries have been instrumental in quality measurement, improvement, and assurance of intensive care. In this article, the development and pilot implementation of the Intensive Care Unit Quality Management Registry are described, with a particular focus on monitoring the quality and operational cost in an adult ICU at a northern Greek state hospital. A relational database was developed for a hospital ICU so that qualitative and financial data are recorded for further analysis needed for planning quality care improvement and enhanced efficiency. Key features of this database registry were low development cost, user friendliness, maximum data security, and interoperability in existing hospital information systems. The database included patient demographics, nursing and medical parameters, and quality and performance indicators as established in many national registries worldwide. Cost recording was based on a mixed approach: at patient level ("bottom-up" method) and at department level ("top-down" method). During the pilot phase of the database operation, regular monitoring of quality and cost data revealed several fields of quality excellence, while indicating room for improvement for others. Parallel recording and trending of multiple parameters showed that the database can be utilized for optimum ICU quality and cost management and also for further research purposes by nurses, physicians, and administrators.

  6. Cod monitoring; results 2015, quarter 3

    NARCIS (Netherlands)

    Reijden, van der K.J.; Machiels, M.A.M.; Trapman, B.K.; Kraan, M.L.

    2015-01-01

    The Cod monitoring program is part of the Dutch cod avoidance plan developed by the Dutch Government together with the Dutch fishing sector. The aim of this cod monitoring program is to provide information on the Catch per Unit Effort (CpUE) in the TR fleet (bottom trawls and seines). This is needed

  7. Cod monitoring : results 2015, quarter 2

    NARCIS (Netherlands)

    Teal, L.R.; Reijden, van der K.J.; Machiels, M.A.M.; Kraan, M.L.

    2015-01-01

    The Cod monitoring program is part of the Dutch cod avoidance plan developed by the Dutch Government together with the Dutch fishing sector. The aim of this cod monitoring program is to provide information on the Catch per Unit Effort (CpUE) in the TR fleet (bottom trawls and seines). This is needed

  8. Linear accelerator calibration monitor with a memory

    International Nuclear Information System (INIS)

    Dixon, R.L.; Ekstrand, K.E.

    1979-01-01

    A calibration monitor has been designed for measuring the constancy of linear accelerator or cobalt unit output between full calibrations. This monitor is battery-operated, light-weight, and slides into the shadow tray attachment on a linear accelerator or cobalt unit for easy setup. It provides a digital readout of the dose delivered, and a consistency check can be made in less than two minutes. The precision of the monitor, determined by cobalt-60 irradiations over a 2 1/2 month period, is +- 0.6% (standard deviation). The monitor also retains the dose reading in a CMOS digital counter indefinitely, hence it can be used in the same fashion as mailed thermoluminescent dosimeters (TLD) for calibration checks at remote facilities without the complicated readout procedures associated with TLD. The monitor can be mailed to a remote facility, positioned without ambiguity, and irradiated; and the reading can be verified on return to the originating center simply by pressing a switch. The monitor can easily be set up to carry out a ''blind'' check in which the reading obtained is not known to the remote facility

  9. Relative contribution of different altered motor unit control to muscle weakness in stroke: a simulation study

    Science.gov (United States)

    Shin, Henry; Suresh, Nina L.; Zev Rymer, William; Hu, Xiaogang

    2018-02-01

    Objective. Chronic muscle weakness impacts the majority of individuals after a stroke. The origins of this hemiparesis is multifaceted, and an altered spinal control of the motor unit (MU) pool can lead to muscle weakness. However, the relative contribution of different MU recruitment and discharge organization is not well understood. In this study, we sought to examine these different effects by utilizing a MU simulation with variations set to mimic the changes of MU control in stroke. Approach. Using a well-established model of the MU pool, this study quantified the changes in force output caused by changes in MU recruitment range and recruitment order, as well as MU firing rate organization at the population level. We additionally expanded the original model to include a fatigue component, which variably decreased the output force with increasing length of contraction. Differences in the force output at both the peak and fatigued time points across different excitation levels were quantified and compared across different sets of MU parameters. Main results. Across the different simulation parameters, we found that the main driving factor of the reduced force output was due to the compressed range of MU recruitment. Recruitment compression caused a decrease in total force across all excitation levels. Additionally, a compression of the range of MU firing rates also demonstrated a decrease in the force output mainly at the higher excitation levels. Lastly, changes to the recruitment order of MUs appeared to minimally impact the force output. Significance. We found that altered control of MUs alone, as simulated in this study, can lead to a substantial reduction in muscle force generation in stroke survivors. These findings may provide valuable insight for both clinicians and researchers in prescribing and developing different types of therapies for the rehabilitation and restoration of lost strength after stroke.

  10. Overview of PAT process analysers applicable in monitoring of film coating unit operations for manufacturing of solid oral dosage forms.

    Science.gov (United States)

    Korasa, Klemen; Vrečer, Franc

    2018-01-01

    Over the last two decades, regulatory agencies have demanded better understanding of pharmaceutical products and processes by implementing new technological approaches, such as process analytical technology (PAT). Process analysers present a key PAT tool, which enables effective process monitoring, and thus improved process control of medicinal product manufacturing. Process analysers applicable in pharmaceutical coating unit operations are comprehensibly described in the present article. The review is focused on monitoring of solid oral dosage forms during film coating in two most commonly used coating systems, i.e. pan and fluid bed coaters. Brief theoretical background and critical overview of process analysers used for real-time or near real-time (in-, on-, at- line) monitoring of critical quality attributes of film coated dosage forms are presented. Besides well recognized spectroscopic methods (NIR and Raman spectroscopy), other techniques, which have made a significant breakthrough in recent years, are discussed (terahertz pulsed imaging (TPI), chord length distribution (CLD) analysis, and image analysis). Last part of the review is dedicated to novel techniques with high potential to become valuable PAT tools in the future (optical coherence tomography (OCT), acoustic emission (AE), microwave resonance (MR), and laser induced breakdown spectroscopy (LIBS)). Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Corrosion strength monitoring of NPP component residual lifetime

    International Nuclear Information System (INIS)

    Denisov, V.G.; Belous, V.N.; Arzhaev, A.I.; Shuvalov, V.A.

    1994-01-01

    Importance of corrosion and fatigue monitoring; types of corrosion determine the NPP equipment life; why automated on-line corrosion and fatigue monitoring is preferable; major stages of lifetime monitoring system development; major groups of sensors for corrosion and strength monitoring system; high temperature on-line monitoring of water chemistry and corrosion; the RBMK-1000 NPP unit automatic water chemistry and corrosion monitoring scheme; examples of pitting, crevice and general corrosion forecast calculations on the basis of corrosion monitoring data; scheme of an experimental facility for water chemistry and corrosion monitoring sensor testing. 2 figs., 4 tabs

  12. X-ray structure of a soluble Rieske-type ferredoxin from Mus musculus

    International Nuclear Information System (INIS)

    Levin, Elena J.; Elsen, Nathaniel L.; Seder, Kory D.; McCoy, Jason G.; Fox, Brian G.; Phillips Jr, George N.

    2008-01-01

    The X-ray crystal structure of a soluble Rieske ferredoxin from M. musculus was solved at 2.07 Å resolution, revealing an iron–sulfur cluster-binding domain with similar architecture to the Rieske-type domains of bacterial aromatic dioxygenases. The ferredoxin was also shown to be capable of accepting electrons from both eukaryotic and prokaryotic oxidoreductases. The 2.07 Å resolution X-ray crystal structure of a soluble Rieske-type ferredoxin from Mus musculus encoded by the gene Mm.266515 is reported. Although they are present as covalent domains in eukaryotic membrane oxidase complexes, soluble Rieske-type ferredoxins have not previously been observed in eukaryotes. The overall structure of the mouse Rieske-type ferredoxin is typical of this class of iron–sulfur proteins and consists of a larger partial β-barrel domain and a smaller domain containing Cys57, His59, Cys80 and His83 that binds the [2Fe–2S] cluster. The S atoms of the cluster are hydrogen-bonded by six backbone amide N atoms in a pattern typical of membrane-bound high-potential eukaryotic respiratory Rieske ferredoxins. However, phylogenetic analysis suggested that the mouse Rieske-type ferredoxin was more closely related to bacterial Rieske-type ferredoxins. Correspondingly, the structure revealed an extended loop most similar to that seen in Rieske-type ferredoxin subunits of bacterial aromatic dioxygenases, including the positioning of an aromatic side chain (Tyr85) between this loop and the [2Fe–2S] cluster. The mouse Rieske-type ferredoxin was shown to be capable of accepting electrons from both eukaryotic and prokaryotic oxidoreductases, although it was unable to serve as an electron donor for a bacterial monooxygenase complex. The human homolog of mouse Rieske-type ferredoxin was also cloned and purified. It behaved identically to mouse Rieske-type ferredoxin in all biochemical characterizations but did not crystallize. Based on its high sequence identity, the structure of the

  13. 40 CFR 60.563 - Monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... input design capacity of less than 150 million Btu/hr, a temperature monitoring device shall be... input design capacity of 150 million Btu/hr or greater, such records to indicate the periods of... monitoring device shall be installed at the outlet of the absorber. (5) If a condenser is the final unit in a...

  14. Study of behaviour of the monitor chambers of a linear accelerator for medical use

    International Nuclear Information System (INIS)

    Brosed, A.; Lopez-Bote, M.A.; Blanco, M.A.; Galvez, M.

    1988-01-01

    An experimental procedure to study the nature and behaviour of the monitor chambers of a linear accelerator for medical use is presented. The procedure has been applied to a Siemens accelerator, Mevatron-77, that has two different types of monitor chambers: sealed for the photon beam and unsealed for the electron ones. As it was expected, no deviations in the dose per monitor unit has been obtained for the photon beam. Variations in the absorbed dose per monitor unit have been observed for the electron beams up to 6% along the working day. Practical solutions compensating this fact are pointed out and the standard recommendations on the control of dose per monitor unit are discussed. (Author)

  15. Radioactive Plumes Monitoring Simulator

    International Nuclear Information System (INIS)

    Kapelushnik, I.; Sheinfeld, M.; Avida, R.; Kadmon, Y.; Ellenbogen, M.; Tirosh, D.

    1999-01-01

    The Airborne Radiation Monitoring System (ARMS) monitors air or ground radioactive contamination. The contamination source can be a radioactive plume or an area contaminated with radionuclides. The system is based on two major parts, an airborne unit carried by a helicopter and a ground station carried by a truck. The system enables real time measurement and analysis of radioactive plumes as well as post flight processing. The Radioactive Plumes Monitoring Simulator purpose is to create a virtual space where the trained operators experience full radiation field conditions, without real radiation hazard. The ARMS is based on a flying platform and hence the simulator allows a significant reduction of flight time costs

  16. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  17. Software structure for tritium-in-air monitoring in classified locations

    International Nuclear Information System (INIS)

    Ionete, Eusebiu Ilarian; Benchea, Dumitru

    2009-01-01

    Full text: In the working areas of heavy water detritiation facilities, were hydrogen gas is generated, the risk of air-hydrogen explosive mixture production is present. This paper gives the description of a software architecture solution for a fixed area tritium-in-air monitoring system suitable to be used in such hazardous locations. Tritium-in-air monitoring system was designed as a distributed system containing a number of fixed tritium in air monitoring units, each of them being composed of an ionisation chamber flow-through type and a fix sampling unit with a number of sample lines and one additional blow line. For each unit, software and hardware architecture structure enable independent performance with a fail-safe concept, remote control operation and data storage in a DCS-DCU module. This software architecture secures the setting possibility of alarm levels for tritium concentration, graphical visualisation and acoustic alarm in the case of level overtaking. The afferent software architecture contains applications in connection with hardware architecture and with a hydrogen detection system: RU-1 software application for control sampling; RU-2 software application for measured values display; RU-3 software application for remote data display; RU-4 software application for SQL conversion server; RU-5 software application for OPC standard conversion. The interconnection of all hardware components, between each PLC and each display unit, between tritium-in-air monitoring units and PLC sampling units will be internally carried out using interfaces. The interconnection between PLCs and tritium-in-air monitoring DCU will be made using a communication network, for instance Ethernet Profibus or RS 485. (authors)

  18. RadNet Radiological Air Monitoring Network

    International Nuclear Information System (INIS)

    Scott Telofski, J.; Askren, D.R.; Petko, Ch.M.; Fraass, R.G.

    2010-01-01

    The United States Environmental Protection Agency operates a national environmental radiation monitoring program called RadNet. RadNet monitors airborne particulates, precipitation, milk, and drinking water for radiation levels. The primary purpose of the original program in the 1950's and 1960's was to collect and analyze samples in various media to assess the effects of radioactive fallout from above-ground nuclear weapon testing. As above-ground testing diminished in the 1970's, the program, especially the air network, became critical in evaluating effects of other types of nuclear incidents, such as the nuclear reactor accident at Chernobyl, as well as monitoring trends in environmental radioactive contamination. The value of rapid data collection subsequent to such incidents led to the consideration of developing air monitors with radiation detectors and telecommunication equipment for real-time radiation measurement. The strengthened United States homeland security posture after 2001 led to production and installation of the current real-time RadNet air monitors. There are now 118 stationary, continuously operating air monitoring stations and 40 mobile air monitors for site specific monitoring. The stationary air monitors include radiation detectors, meteorological sensors, a high-volume air sampler, and communication devices for hourly data transfers. When unusual levels are detected, scientists download a full sodium iodide detector spectrum for analysis. The real-time data collected by RadNet stationary systems permit rapid identification and quantification of airborne nuclides with sufficient sensitivity to provide critical information to help determine protective actions. The data also may help to rapidly refine long-range radioactive plume models and estimate exposure to the population. This paper provides an overview of the airborne particulate monitoring conducted during above-ground nuclear weapon testing, summarizes the uses of data from the program

  19. A Piezoelectric Passive Wireless Sensor for Monitoring Strain

    Science.gov (United States)

    Zou, Xiyue; Ferri, Paul N.; Hogan, Ben; Mazzeo, Aaron D.; Hull. Patrick V.

    2017-01-01

    Interest in passive wireless sensing has grown over the past few decades to meet demands in structural health monitoring.(Deivasigamani et al., 2013; Wilson and Juarez, 2014) This work describes a passive wireless sensor for monitoring strain, which does not have an embedded battery or chip. Without an embedded battery, the passive wireless sensor has the potential to maintain its functionality over long periods in remote/harsh environments. This work also focuses on monitoring small strain (less than 1000 micro-?). The wireless sensing system includes a reader unit, a coil-like transponder, and a sensing unit. It operates in the Megahertz (MHz) frequency range, which allows for a few centimeters of separation between the reader and sensing unit during measurements. The sensing unit is a strain-sensitive piezoelectric resonator that maximizes the energy efficiency at the resonance frequency, so it converts nanoscale mechanical variations to detectable differences in electrical signal. In response to an external loading, the piezoelectric sensor breaks from its original electromechanical equilibrium, and the resonant frequency shifts as the system reaches a new balanced equilibrium. In this work, the fixture of the sensing unit is a small, sticker-like package that converts the surface strain of a test material to measurable shifts in resonant frequencies. Furthermore, electromechanical modeling provides a lumped-parameter model of the system to describe and predict the measured wireless signals of the sensor. Detailed characterization demonstrates how this wireless sensor has resolution comparable to that of conventional wired strain sensors for monitoring small strain.

  20. The United Nations and Its Critics.

    Science.gov (United States)

    Menon, Bhaskar P.

    1989-01-01

    Provides a brief history of the development of the United Nations. Identifies achievements of the United Nations in the promotion of human rights, the translation of the Universal Declaration of Human Rights into binding international covenants, and the establishment of monitoring mechanisms to ensure the protection of human rights. (KO)

  1. Remote Working Level Monitor. Final report

    International Nuclear Information System (INIS)

    1977-01-01

    The Remote Working Level Monitor (RWLM) is an instrument used to remotely monitor the RN-daughter concentrations and the Working Level (WL). It is an ac powered, microprocessor based instrument which multiplexes two independent detector units to a single central processor unit (CPU). The CPU controls the actuation of the detector units and processes and outputs the data received from these remote detector units. The remote detector units are fully automated and require no manual operation once they are set up. They detect and separate the alpha emitters of RaA and RaC' as well as detecting the beta emitters of RaB and RaC. The resultant pulses from these detected radioisotopes are transmitted to the CPU for processing. The programmed microprocessor performs the mathematical manipulations necessary to output accurate Rn-daughter concentrations and the WL. A special subroutine within the program enables the RWLM to run and output a calibration procedure on command. The data resulting from this request can then be processed in a separate program on most computers capable of BASIC programming. The calibration program results in the derivation of coefficients and beta efficiencies which provides calibrated coefficients and beta efficiencies

  2. Praksis Pembelajaran Kewirausahaan pada Unit Produksi Jasa Boga

    Directory of Open Access Journals (Sweden)

    Tuatul Mahfud

    2013-01-01

    Full Text Available Abstrak: Praksis pembelajaran kewirausahaan pada unit produksi jasa boga. Penelitian bertujuan menemukan konsepsi guru tentang pembelajaran kewirausahaan, kompetensi kewirausahaan yang dikembangkan pada unit produksi sekolah dalam bidang jasa boga. Penelitian ini menggunakan metode kualitatif jenis studi kasus. Subjek penelitian adalah kepala sekolah, ketua program studi, kepala unit produksi, dan siswa. Data dikumpulkan melalui wawancara, observasi, dan dokumentasi dan dianalisis menggunakan model interaktif dari Miles dan Huberman yang terdiri dari reduksi data, data display, dan kesimpulan. Hasil penelitian menunjukkan bahwa: (1 belajar kewirausahaan memerlukan kegiatan nyata (hands-on dengan melibatkan siswa pada kegiatan usaha yang nyata dalam unit produksi; (2 kompetensi kewirausahaan dikembangkan melalui unit produksi adalah: pengetahuan tentang kewirausahaan melalui pengetahuan diri dan pengetahuan praktis; sikap kewirausahaan meliputi etos kerja, disiplin, kemandirian, dan kreativitas, keterampilan berkomunikasi, keterampilan konseptual, keterampilan pengambilan keputusan, keterampilan mengatur waktu, keterampilan kepemimpinan. Model pembelajaran kewirausahaan yang dikembangkan melalui unit produksi adalah: produksi luar dan produksi dalam, dan kantin mobil. Evaluasi dan monitoring dilakukan melalui dua cara, dengan monitoring kinerja dan produk. Kata Kunci: pembelajaran, entrepreneurship, unit produksi

  3. Circumpolar Biodiversity Monitoring Programme coastal biodiversity monitoring background paper

    Science.gov (United States)

    McLennan, Donald; Anderson, Rebecca D.; Wegeberg, S.; Pettersvik Arvnes, Maria; Sergienko, Liudmila; Behe, Carolina; Moss-Davies, Pitseolak; Fritz, S.; Markon, Carl J.; Christensen, T.; Barry, T.; Price, C.

    2016-01-01

    In 2014, the United States (U.S.) and Canada agreed to act as co-lead countries for the initial development of the Coastal Expert Monitoring Group (CEMG) as part of the Circumpolar Biodiversity Monitoring Program (CBMP, www. cbmp.is) under the Arctic Council’s Conservation of Arctic Flora and Fauna (CAFF, www.caff.is) working group. The CAFF Management Board approved Terms of Reference for the CEMG in the spring of 2014. The primary goal of the CEMG is to develop a long term, integrated, multi-disciplinary, circumpolar Arctic Coastal Biodiversity Monitoring Plan (the Coastal Plan) that relies on science and Traditional Knowledge, and has direct and relevant application for communities, industry, government decision makers, and other users. In addition to the monitoring plan, the CAFF working group has asked the CBMP, and thus the CEMG, to develop an implementation plan that identifies timeline, costs, organizational structure and partners. This background paper provides a platform for the guidance for the development of the Coastal Plan and is produced by the CEMG with assistance from a number of experts in multiple countries.

  4. Helium gas purity monitor based on low frequency acoustic resonance

    Science.gov (United States)

    Kasthurirengan, S.; Jacob, S.; Karunanithi, R.; Karthikeyan, A.

    1996-05-01

    Monitoring gas purity is an important aspect of gas recovery stations where air is usually one of the major impurities. Purity monitors of Katherometric type are commercially available for this purpose. Alternatively, we discuss here a helium gas purity monitor based on acoustic resonance of a cavity at audio frequencies. It measures the purity by monitoring the resonant frequency of a cylindrical cavity filled with the gas under test and excited by conventional telephone transducers fixed at the ends. The use of the latter simplifies the design considerably. The paper discusses the details of the resonant cavity and the electronic circuit along with temperature compensation. The unit has been calibrated with helium gas of known purities. The unit has a response time of the order of 10 minutes and measures the gas purity to an accuracy of 0.02%. The unit has been installed in our helium recovery system and is found to perform satisfactorily.

  5. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    Science.gov (United States)

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  6. Microcontroller based motion control interface unit for double slit type beam emittance monitor for H- ion source

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Jain, Rahul; Karnewar, A.K.; Sonawane, B.B.; Maurya, N.K.; Puntambekar, T.A.

    2015-01-01

    The Indian Spallation Neutron Source (ISNS), proposed to be developed at RRCAT, will use a 1 GeV H - linac and an accumulator ring to produce high flux of pulsed neutrons via spallation process. The development activity of front end of 1H - linac for ISNS is under progress at RRCAT, for which a pulsed H - ion source of 50 keV energy, 30 mA current with pulse width of 500 μs has been developed at RRCAT. In this paper, we present the design and development of a microcontroller based motion control interface unit for double slit type beam emittance monitor for the H - ion source. This is an interceptive type of beam diagnostic device, which is used for the quantitative measurement of transverse emittance and beam intensity profile

  7. A real-time virtual delivery system for photon radiotherapy delivery monitoring

    Directory of Open Access Journals (Sweden)

    Feng Shi

    2014-03-01

    Full Text Available Purpose: Treatment delivery monitoring is important for radiotherapy, which enables catching dosimetric error at the earliest possible opportunity. This project develops a virtual delivery system to monitor the dose delivery process of photon radiotherapy in real-time using GPU-based Monte Carlo (MC method.Methods: The simulation process consists of 3 parallel CPU threads. A thread T1 is responsible for communication with a linac, which acquires a set of linac status parameters, e.g. gantry angles, MLC configurations, and beam MUs every 20 ms. Since linac vendors currently do not offer interface to acquire data in real time, we mimic this process by fetching information from a linac dynalog file at the set frequency. Instantaneous beam fluence map (FM is calculated based. A FM buffer is also created in T1 and the instantaneous FM is accumulated to it. This process continues, until a ready signal is received from thread T2 on which an in-house developed MC dose engine executes on GPU. At that moment, the accumulated FM is transferred to T2 for dose calculations, and the FM buffer in T1 is cleared. Once the dose calculation finishes, the resulting 3D dose distribution is directed to thread T3, which displays it in three orthogonal planes in color wash overlaid on the CT image. This process continues to monitor the 3D dose distribution in real-time.Results: An IMRT and a VMAT cases used in our patient-specific QA are studied. Maximum dose differences between our system and treatment planning system are 0.98% and 1.58% for the IMRT and VMAT cases, respectively. The update frequency is >10Hz and the relative uncertainty level is 2%.Conclusion: By embedding a GPU-based MC code in a novel data/work flow, it is possible to achieve real-time MC dose calculations to monitor delivery process.------------------------------Cite this article as: Shi F, Gu X, Graves YJ, Jiang S, Jia X. A real-time virtual delivery system for photon radiotherapy delivery

  8. Outcomes of an innovative model of acute delirium care: the Geriatric Monitoring Unit (GMU

    Directory of Open Access Journals (Sweden)

    Chong MS

    2014-04-01

    Full Text Available Mei Sian Chong, Mark Chan, Laura Tay, Yew Yoong Ding Department of Geriatric Medicine, Institute of Geriatrics and Active Ageing, Tan Tock Seng Hospital, Singapore Objective: Delirium is associated with poor outcomes following acute hospitalization. The Geriatric Monitoring Unit (GMU is a specialized five-bedded unit for acute delirium care. It is modeled after the Delirium Room program, with adoption of core interventions from the Hospital Elder Life Program and use of evening light therapy to consolidate circadian rhythms and improve sleep in older inpatients. This study examined whether the GMU program improved outcomes in delirious patients. Method: A total of 320 patients, including 47 pre-GMU, 234 GMU, and 39 concurrent control subjects, were studied. Clinical characteristics, cognitive status, functional status (Modified Barthel Index [MBI], and chemical restraint-use data were obtained. We also looked at in-hospital complications of falls, pressure ulcers, nosocomial infection rate, and discharge destination. Secondary outcomes of family satisfaction (for the GMU subjects were collected. Results: There were no significant demographic differences between the three groups. Pre-GMU subjects had longer duration of delirium and length of stay. MBI improvement was most evident in the GMU compared with pre-GMU and control subjects (19.2±18.3, 7.5±11.2, 15.1±18.0, respectively (P<0.05. The GMU subjects had a zero restraint rate, and pre-GMU subjects had higher antipsychotic dosages. This translated to lower pressure ulcer and nosocomial infection rate in the GMU (4.1% and 10.7%, respectively and control (1.3% and 7.7%, respectively subjects compared with the pre-GMU (9.1% and 23.4%, respectively subjects (P<0.05. No differences were observed in mortality or discharge destination among the three groups. Caregivers of GMU subjects felt the multicomponent intervention to be useful, with scheduled activities voted the most beneficial in patient

  9. Offsite environmental monitoring report; radiation monitoring around United States nuclear test areas, Calendar Year 1996

    International Nuclear Information System (INIS)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Huff, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1997-08-01

    This report describes the Offsite Radiation Safety Program. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs). No nuclear weapons testing was conducted in 1996 due to the continuing nuclear test moratorium. During this period, R and IE personnel maintained readiness capability to provide direct monitoring support if testing were to be resumed and ascertained compliance with applicable EPA, DOE, state, and federal regulations and guidelines. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no airborne radioactivity from diffusion or resuspension detected by the various EPA monitoring networks surrounding the NTS. There was no indication of potential migration of radioactivity to the offsite area through groundwater and no radiation exposure above natural background was received by the offsite population. All evaluated data were consistent with previous data history

  10. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  11. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.

    1994-03-01

    This report presents the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1993. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  12. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1993-03-01

    This report present the results of the NRC Direct Radiation Monitoring Network for the fourth quarter of 1992. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program

  13. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  14. Ethiopia before the United Nations Treaty Monitoring Bodies

    Directory of Open Access Journals (Sweden)

    Eva Brems

    2007-08-01

    Full Text Available Among the many human rights conventions adopted by the UN, seven are known — together with their additional protocols — as the core international human rights instruments: - The International Convention on the Elimination of All Forms of Racial Discrimination; - The International Covenant on Civil and Political Rights; - The International Covenant on Economic, Social and Cultural Rights; - The Convention on the Elimination of all Forms of Discrimination against Women; - The Convention against Torture and other Cruel, Inhuman or Degrading Treatment or Punishment; - The Convention on the Rights of the Child;  - The International Convention on the Protection of the Rights of all Migrant Workers and Members of their Families.  The main international control mechanism under these conventions is what may be considered the standard mechanism in international human rights protection: state reporting before an international committee. An initial report is due usually one year after joining the treaty and afterwards, reports are due periodically (every four or five years. The international committees examine the reports submitted by the state parties. In the course of this examination they include information from other sources, such as the press, other United Nations materials or NGO information. They also hold a meeting with representatives of the state submitting the report. At the end of this process the committee issues 'concluding observations' or 'concluding comments'. This paper focuses on the experience of one state — Ethiopia - with the seven core human rights treaties. This should allow the reader to gain insights both into the human rights situation in Ethiopia and in the functioning of the United Nations human rights protection system. Key Words: United Nations, Human Rights Conventions, State Reporting, Human Rights Situation in Ethiopia

  15. Automated contamination monitoring for hot particles

    International Nuclear Information System (INIS)

    Johnstone, G.; Case, L.

    1987-01-01

    INS Corp., the largest nuclear laundry company in the United States, has recently developed two types of automated contamination monitoring systems: 1) the Automated Laundry Monitor (ALM), which provides quality assurance monitoring for protective clothing contamination and 2) a low-level automated monitoring system for Plastic Volume Reduction Service (PVRS). The presentation details the inaccuracies associated with hand-probe frisking which led to the development of the ALM. The ALM was designed for 100% quality assurance monitoring of garments to the most stringent customer requirements. A review of why the ALM is essential in verifying the absence of hot particles on garments is given. The final topic addresses the expansion of the ALM technology in support of the INS Plastic Volume Reduction Service by monitoring decontaminated plastics to free release levels. This presentation reviews the design and operation of both monitoring systems

  16. Development of a Real-Time Thermal Performance Diagnostic Monitoring system Using Self-Organizing Neural Network for Kori-2 Nuclear Power Unit

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1996-01-01

    In this work, a PC-based thermal performance monitoring system is developed for the nuclear power plants. the system performs real-time thermal performance monitoring and diagnosis during plant operation. Specifically, a prototype for the Kori-2 nuclear power unit is developed and examined is very difficult because the system structure is highly complex and the components are very much inter-related. In this study, some major diagnostic performance parameters are selected in order to represent the thermal cycle effectively and to reduce the computing time. The Fuzzy ARTMAP, a self-organizing neural network, is used to recognize the characteristic pattern change of the performance parameters in abnormal situation. By examination, the algorithm is shown to be ale to detect abnormality and to identify the fault component or the change of system operation condition successfully. For the convenience of operators, a graphical user interface is also constructed in this work. 5 figs., 3 tabs., 11 refs. (Author)

  17. The international remote monitoring project and implication

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    The future of remote monitoring in International Safeguards system is analyzed. Problems of an update on the International Remote Monitoring Project are considered. The Project allows to remotely transmit safeguards-relevant data directly to IAEA from nuclear facilities worldwide. Description of integrated monitoring system (IMS) is given. A key element of state-of-art of IMS is modular nodal system which accepts information from sensors and provides information to both a data storage unit and a transmitter. Remote Monitoring Systems of Australia and Sweden are presented. 3 figs

  18. Increasing use of less-invasive hemodynamic monitoring in 3 specialty surgical intensive care units: a 5-year experience at a tertiary medical center.

    Science.gov (United States)

    Kirton, Orlando C; Calabrese, Rebecca C; Staff, Ilene

    2015-01-01

    Less-invasive hemodynamic monitoring (eg, esophageal doppler monitoring [EDM] and arterial pressure contour analysis, FloTrac) is increasingly used as an alternative to pulmonary artery catheters (PACs) in critically ill intensive care unit (ICU). The decrease in use of PACs is not associated with increased mortality. Five-year retrospective review of 1894 hemodynamically monitored patients admitted to 3 surgical ICUs in a university-affiliate, tertiary care urban hospital. Data included the number of admissions, diagnosis-related group discharge case mix, length of stay, insertion of monitoring devices (PAC, EDM, and FloTrac probes), administered intravenous vasoactive agents (β-predominant agonists--dobutamine, epinephrine, and dopamine; vasopressors--norepinephrine and phenylephrine), and mortality. Data from hospital administrative databases were compiled to create patient characteristic and monitoring variables across a 5-year time period, 2005 to 2009 inclusive. Chi-square for independent proportions, 1-way analysis of variance, and Kruskal-Wallis tests were used; tests for trend were conducted. An α level of .05 was considered significant. Statistical Package for the Social Sciences v14 was used for all statistical testing. There was a significant change in the type of hemodynamic monitors inserted in 2 of the 3 surgical ICUs (in the general surgery and neurointensive care but not in the cardiac ICU) from PACs to less-invasive devices (FloTrac or EDM) during the 5-year study period (P < .001). There was no change in mortality rate over the time period (P = .492). There was an overall increase in the proportion of monitored patients who received intravenous vasoactive agents (P < .001) with a progressive shift from β-agonists to vasopressors (P < .002). Multivariate analyses indicated that age, case mix, and use of vasoactive agents were all independent predictors of inhospital mortality (P = .001) but that type of monitoring was not (P = .638). In a 5

  19. Effect of Electronic Monitoring on Social Welfare Dependence

    DEFF Research Database (Denmark)

    Andersen, Lars Højsgaard; Andersen, Signe Hald

    2014-01-01

    Research Summary We studied the effect on unemployment social welfare dependence of serving a sentence under elec-tronic monitoring rather than in prison, using Danish registry data and two policy shifts that extended the use of electronic monitoring in Denmark. We found electronic monitoring...... to experiences from other contexts. The experiences from Denmark are clear: Electronic monitoring is less harmful than imprisonment to the life course out-comes of offenders. Since electronic monitoring could also very well be less costly for the corrections administrations than imprisonment, efforts to extend...... the use of electronic monitoring in the United States could be accelerated....

  20. FFI: A software tool for ecological monitoring

    Science.gov (United States)

    Duncan C. Lutes; Nathan C. Benson; MaryBeth Keifer; John F. Caratti; S. Austin Streetman

    2009-01-01

    A new monitoring tool called FFI (FEAT/FIREMON Integrated) has been developed to assist managers with collection, storage and analysis of ecological information. The tool was developed through the complementary integration of two fire effects monitoring systems commonly used in the United States: FIREMON and the Fire Ecology Assessment Tool. FFI provides software...

  1. Environmental monitoring systems: a new type of mobile laboratory

    International Nuclear Information System (INIS)

    Bruecher, L.; Langmueller, G.; Tuerschmann, G.

    1999-01-01

    Nuclear facilities are obligated to monitor the environmental radiation in their vicinity, which is often fulfilled by monitoring cars, combined with fixed monitoring stations. The MOLAR Mobile Laboratory for Environmental Radiation Monitoring as described here is being used under normal and accident conditions as a spot check monitoring system or to perform continuous measurements along a driving track. The mobile laboratories are continuously connected with the control centre's CRCS Central Radiological Computer System, where the RIS Radiological Information System provides corresponding evaluation functions. The mobile labs contain measuring and controlling units like γ-dose rate monitors, γ-spectrometer with a HpGe High Purity Germanium detector, a lead shielded measuring cell and MCA Multi-Channel Analyser, portable β-contamination monitor, α/β/γ multipurpose quick measuring unit, aerosol and iodine sampling units. The collected samples are safely stored for the transport to the environmental laboratory for being analysed later. The geographical location of the moving car is continuously determined by the satellite based GPS Global Positioning System and transferred in the on-board rack mounted computer system for being stored and locally displayed. Real-time data transmission via radio and mobile phone is continuously performed to supply the RIS Radiological Information System in the control centre via radio and mobile phone. The latter also serves for voice communication. Currently three MOLAR systems can be operated parallel and independent from the control centre. The system is ready to be extended to more mobile labs. This combination of mobile monitoring, sample analysis and radiological assessment of environmental data in combination with process occurrences has turned out to be a powerful instrument for emergency preparedness and environmental supervising. (orig.) [de

  2. The United Kingdom Acid Waters Monitoring Network: a review of the first 15 years and introduction to the special issue

    International Nuclear Information System (INIS)

    Monteith, D.T.; Evans, C.D.

    2005-01-01

    The United Kingdom Acid Waters Monitoring Network (AWMN) was established in 1988 to determine the ecological impact of acidic emissions control policy on acid-sensitive lakes and streams. AWMN data have been used to explore a range of causal linkages necessary to connect changes in emissions to chemical and, ultimately, biological recovery. Regional scale reductions in sulphur (S) deposition have been found to have had an immediate influence on surface water chemistry, including increases in acid neutralising capacity, pH and alkalinity and declines in aluminium toxicity. These in turn can be linked to changes in the aquatic biota which are consistent with 'recovery' responses. A continuation of the current programme is essential in order to better understand apparent non-linearity between nitrogen (N) in deposition and runoff, the substantial rise in organic acid concentrations, and the likely impacts of forecast climate change and other potential constraints on further biological improvement. - After 15 years of the UK Acid Waters Monitoring Network, we can now draw clear conclusions regarding the impact of emission reductions on acidified UK fresh waters

  3. A Technical Evaluation of Wireless Connectivity from Patient Monitors to an Anesthesia Information Management System During Intensive Care Unit Surgery.

    Science.gov (United States)

    Simpao, Allan F; Galvez, Jorge A; England, W Randall; Wartman, Elicia C; Scott, James H; Hamid, Michael M; Rehman, Mohamed A; Epstein, Richard H

    2016-02-01

    Surgical procedures performed at the bedside in the neonatal intensive care unit (NICU) at The Children's Hospital of Philadelphia were documented using paper anesthesia records in contrast to the operating rooms, where an anesthesia information management system (AIMS) was used for all cases. This was largely because of logistical problems related to connecting cables between the bedside monitors and our portable AIMS workstations. We implemented an AIMS for documentation in the NICU using wireless adapters to transmit data from bedside monitoring equipment to a portable AIMS workstation. Testing of the wireless AIMS during simulation in the presence of an electrosurgical generator showed no evidence of interference with data transmission. Thirty NICU surgical procedures were documented via the wireless AIMS. Two wireless cases exhibited brief periods of data loss; one case had an extended data gap because of adapter power failure. In comparison, in a control group of 30 surgical cases in which wired connections were used, there were no data gaps. The wireless AIMS provided a simple, unobtrusive, portable alternative to paper records for documenting anesthesia records during NICU bedside procedures.

  4. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  5. BIOAKTIFITAS BUNGA SEPATU (Hibiscus rosa-sinensis L. TERHADAP KADAR KOLESTEROL DARAH MENCIT (Mus musculus YANG MENGALAMI HIPERKOLESTEROLEMIA DENGAN DIET TINGGI LEMAK

    Directory of Open Access Journals (Sweden)

    Rinza Rahmawati Samsudin

    2017-12-01

      Tujuan penelitian ini adalah untuk mengetahui pengaruh bioaktifitas ekstrak bunga sepatu (Hibiscus rosa-sinensis l. terhadap  kadar kolesterol darah mencit (Mus musculus yang mengalami hiperkolesterolemia dengan diet tinggi lemak. Penelitian ini merupakan penelitian eksperimental murni, dengan menggunakan rancangan randomized post-test only control group design. Bunga sepatu mengandung pigmen antosianin yang termasuk golongan flavonoid yang berperan sebagai antioksidan. Sebanyak dua puluh delapan mencit dibagi menjadi empat kelompok (K1, K2, K3 dan K4. Kelompok K1 adalah kelompok yang mendapat perlakukan pakan tinggi lemak dan aquadest setelah aklimatasi. Kelompok K2, K3, dan K4 adalah kelompok  terapi yang mendapat perlakukan pakan tinggi lemak, ekstrak bunga septum sebanyak 1 ml dan aquadest setelah aklimatasi. Pemberian pakan tinggi lemak berlangsung selama 28 hari. Selama penelitian berlangsung penimbangan berat badan tikus dilakukan sebanyak lima kali. Hasil penelitian menunjukan bahwa pemberian 1 ml ekstrak bunga sepatu selama dua puluh delapan hari dapat menurunkan kadar kolesterol mencit dimana nilai p<0.05.   Kata kunci: ekstrak bunga sepatu, kadar kolesterol, diet tinggi lemak

  6. Aktivitas Penyembuhan Luka Sediaan Topikal Ekstrak Bawang Merah (Allium cepa terhadap Luka Sayat Kulit Mencit (Mus Musculus (THE ACTIVITY OF TOPICAL EXTRACT OF ONIONS (ALLIUM CEPA ON WOUND HEALING PROCESS IN MICE (MUS MUSCULUS

    Directory of Open Access Journals (Sweden)

    Visa Yunanda

    2017-01-01

    Full Text Available Wound healing is a physiological response of the body to restore continuity, structure and function ofthe injured tissue. Onion is one of the plants that are empirically used by the community to heal wounds.The purpose of this study was to observe the effect of topical extract of onions (Allium cepa on woundhealing process in mice (Mus musculus strain BalbC. This study used the posttest-only control groupdesign with completely randomized design (CRD. The samples were 12 male mice with weight ranged of22-32 g divided into four treatments; i.e.: Vaseline, topical extract of onion 5%, topical extract of onion30% and topical extract of onion 55% with 3 replications. Wound healing evaluated macroscopically toobserve hyperemia, wound contraction, granulation, crusting and pus production; and microscopically bycounting the number of fibroblasts on day 10. Hyperemia, granulation, crusting and pus production wereanalyzed descriptively. Wound contraction and the number of fibroblasts were analyzed using ANOVA(p<0.05 and followed with Duncan’s test (p<0,05. Descriptive observations obtained hyperemia lasteduntil day 3, granulation in wounds used topical extract of onion 30% and 55% were faster than the other,crusting lasted until day 6 and the production of pus was not found in any treatment. Statistical testresults showed that topical extract of onion 55% significantly affected wound contraction and topicalextract of onion 30% and 55% significantly affected maturation, which characterized by the decreasednumber of fibroblasts. The results of this study showed that topical extract of onion had significant effect(p<0.05 on wound healing and the effect was in line with the increased concentration of the onion extract.

  7. Interest of Monitoring Diaphragmatic Electrical Activity in the Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Laurence Ducharme-Crevier

    2013-01-01

    Full Text Available The monitoring of electrical activity of the diaphragm (EAdi is a new minimally invasive bedside technology that was developed for the neurally adjusted ventilatory assist (NAVA mode of ventilation. In addition to its role in NAVA ventilation, this technology provides the clinician with previously unavailable and essential information on diaphragm activity. In this paper, we review the clinical interests of EAdi in the pediatric intensive care setting. Firstly, the monitoring of EAdi allows the clinician to tailor the ventilatory settings on an individual basis, avoiding frequent overassistance leading potentially to diaphragmatic atrophy. Increased inspiratory EAdi levels can also suggest insufficient support, while a strong tonic activity may reflect the patient efforts to increase its lung volume. EAdi monitoring also allows detection of patient-ventilator asynchrony. It can play a role in evaluation of extubation readiness. Finally, EAdi monitoring provides the clinician with better understanding of the ventilatory capacity of patients with acute neuromuscular disease. Further studies are warranted to evaluate the clinical impact of these potential benefits.

  8. ON-BOARD MONITORING OF TECHNICAL STATE FOR POWER UNITS OF WHEELED AND TRACKED VEHICLES

    Directory of Open Access Journals (Sweden)

    Yu. D. Karpievich

    2016-01-01

    Full Text Available The paper considers new methodologies pertaining to on-board diagnosis of wear-out rate for friction linings of a clutch driven disk and friction discs of a hydraulic press clutch of transmission gear boxes which are based on physical process that uses friction work as an integrated indicator. A new methodology in determination of life-span rate for engine oil has been developed in the paper. The paper presents block schematic diagrams for on-board monitoring of technical state for power units of wheeled and tracked vehicles. Usage of friction work as an integrated indicator for determination of wear-out rate for friction linings of clutch driven disk and friction discs of a haydraulic press clutch makes it possible timely at any operational period of wheeled and tracked vehicles to determine their residual operation life and forecast their replacement.While taking volume of the used fuel for determination of engine oil life-span rate it permits quickly and effectively at any operational period of wheeled and tracked vehicles to determine residual useful life of the engine oil and also forecast its replacement.

  9. Monitoring of radon gas in caves of the Yorkshire Dales, United Kingdom

    International Nuclear Information System (INIS)

    Langridge, D; Stokes, R P; Jackson, C P

    2010-01-01

    A number of vocational training courses are held in caves in the Yorkshire Dales region of the United Kingdom. The instructors and students involved in these courses have the potential to be exposed to enhanced levels of radon ( 222 Rn) and its progeny as a result of their occupations. A prior radiological risk assessment for the training courses recommended that an environmental monitoring programme be carried out to establish the radon concentrations in the caves, and that the caving instructors wear personal radon dosemeters. Radon gas concentrations varied seasonally, being at their highest in summer and their lowest in winter. The lowest result was 40 Bq m -3 recorded in Lower Longchurn cave during winter, whilst the highest result was 4440 Bq m -3 recorded in Crackpot cave during the summer. As the individuals involved in the caving are entering atmospheres with radon gas concentrations in excess of 400 Bq m -3 , the Ionising Radiation Regulations 1999 (GB Parliament 2000 Ionising Radiations Regulations 1999 (London: Stationary Office) SI 1999/3232) apply. A system of work is therefore in place to control exposure to radon. This system of work stipulates an initial dose investigation level of 1 mSv, a second dose investigation level of 2 mSv and an annual dose limit of 6 mSv. The highest annual dose recorded to date is 2.2 mSv, although the average (median) annual dose is only 0.5 mSv.

  10. Dust and smoke pollution monitoring in industrial unit

    International Nuclear Information System (INIS)

    Shamsi, S.S.

    1995-01-01

    Dust and smoke are the two most commonly emitted industrial pollutants which are visible to the naked eye. Cement plants and power generation plants, based on coal and fuel oil etc. are the most common examples of industry emitting these pollutants. In this article these pollutants have been briefly described and some monitoring instruments for dust and smoke emissions have been specific. These instruments are especially suitable for power station and the cement industry etc. Automotive in urban areas. However, this paper does not include equipment for automotive exhaust pollution. (author)

  11. NRC TLD Direct Radiation Monitoring Network

    International Nuclear Information System (INIS)

    Struckmeyer, R.; McNamara, N.

    1991-04-01

    This report presents the results of the NRC [Nuclear Regulatory Commission] Direct Radiation Monitoring Network for the fourth quarter of 1990. It provides the ambient radiation levels measured in the vicinity of 75 sites throughout the United States. In addition, it describes the equipment used, monitoring station selection criteria, characterization of the dosimeter response, calibration procedures, statistical methods, intercomparison, and quality assurance program. 3 figs., 4 tabs

  12. Conversion of an Alpha CAM Monitor of Victoreen calibrated of factory for plutonium in a measurement monitor of radon in the atmosphere; Conversion de un monitor Alpha CAM de la Victoreen calibrado de fabrica para plutonio en un monitor para medicion de radon en la atmosfera

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico)

    2004-07-01

    It is presented in this work the conversion of a monitor ALPHA CAM of the monitor Victoreen gauged of it manufactures for plutonium in a monitor for radon mensuration in the atmosphere. Those units in that the radon measures are expressed are: peak curies/unit of volume of air to sampling. This way one has to gauge and to supplement the software and the parts that the old one monitor for plutonium. It requires. This task implies: a) To calibrate and to determine the efficiency of the detector of accustomed to state of 1700 mm{sup 2} for alpha particles coming from the radioactive series of the radon. b) to connect in series and to calibrate a flow measurer of air in it lines with the detector. Measures are presented of the ambient air and other places of the the historical area of the city of Puebla obtained with the team Converted ALPHA-CAM. (Author)

  13. Westinghouse power distribution monitoring experience at Duke Power's McGuire Unit 1

    International Nuclear Information System (INIS)

    Grobmyer, L.R.; Cash, M.T.; Kitlan, M.S.; Impink, A.J. Jr.

    1987-01-01

    In the evolution of the Westinghouse methodology of assuring safe core power distributions, emphasis was placed on analysis and not on continuous detailed core monitoring. Power distribution monitoring is currently achieved by periodic surveillances using the movable in-core detector system (MIDS) and by continuous observations of the two-section excore power range detectors. Control of the power distribution is regulated by limits on the indications from these systems, by limits on control rod insertion, and by operational constraints on the position indication systems. As more plants come on line and as more utilities take over the fuel design function for themselves, the desire for better core monitoring becomes evident. Also, the need and desire by the utilities to have more control over their operating margin has motivated the industry to offer and/or upgrade core monitoring systems. Westinghouse and Duke Power are participants in a joint development program to finalize the development of the core on-line surveillance monitoring and operations system (COSMOS). This final stage of development consists of prototype field trials at the McGuire Nuclear Plant. The purpose of the prototype program is to determine how well the design objectives are met and how to improve the system based on the operating experience at McGuire. Another purpose of this prototype program is to generate the necessary experience and information to develop a topical report for the US Nuclear Regulatory Commission to obtain a licensing basis for technical specification relaxation

  14. Monitoring selected arthropods

    Science.gov (United States)

    R. Chris Stanton; David J. Horn; Foster F. Purrington; John W. Peacock; Eric H. Metzler

    2003-01-01

    Arthropod populations were sampled in four study areas in southern Ohio in 1995 to document patterns of arthropod diversity and establish a baseline dataset for long-term monitoring in mixed-oak forests. Pitfall, Malaise, and blacklight traps were operated in 12 treatment units from May through September. Several insect groups were selected for detailed study due to...

  15. The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy

    International Nuclear Information System (INIS)

    Goo, Jang Hyeon; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Park, Jin Hong

    2014-01-01

    The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with TrueBeam TM STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy

  16. SU-E-T-808: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Early-Stage Nasopharyngeal Carcinoma: A Dosimetric Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J-Y; Huang, B-T; Zhang, W-Z [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for early-stage nasopharyngeal carcinoma. Methods: CT datasets of ten patients with early-stage nasopharyngeal carcinoma were included. Dual-arc VMAT and nine-field IMRT plans were generated for each case, and were then compared in terms of planning-target-volume (PTV) coverage, conformity index (CI) and homogeneity index (HI), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided comparable HI and CI of PTVnx (PTV of primary tumor of nasopharynx), superior CI and inferior HI of PTVnd (PTV of lymph nodes), as well as superior CI and comparable HI of PTV60 (high-risk PTV). The VMAT plans provided better sparing of the spinal cord, oral cavity and normal tissue, but inferior sparing of the brainstem planning OAR volume (PRV), larynx and parotids, as well as comparable sparing of the spinal cord PRV, brainstem, lenses, optic nerves, optic chiasm. Moreover, the average planning time (181.6 ± 36.0 min) for the VMAT plans was 171% more than that of the IMRT plans (68.1 ± 7.6 min). The MUs of the VMAT plans (609 ± 43) were 70% lower than those of the IMRT plans (2071 ± 262), while the average delivery time (2.2 ± 0.1 min) was 66% less than that of the IMRT plans (6.6 ± 0.4 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve similar or slightly superior target dose distribution, with no significant advantages on OAR sparing, and it can achieve significant reductions of MUs and delivery time.

  17. SU-E-T-809: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Locally Advanced Laryngeal Carcinoma: A Dosimetric Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, J-Y; Huang, B-T; Zhang, W-Z; Yan, L-J [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2015-06-15

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for locally advanced laryngeal carcinoma. Methods: CT datasets of eleven patients were included. Dual-arc VMAT and 7-field IMRT plans, which were created based on the Eclipse treatment planning system, were compared in terms of dose-volume parameters, conformity index (CI) and homogeneity index (HI) of planning target volume (PTV), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided lower D2% and better CI/HI for the high-risk PTV (PTV1), and provided better CI and comparable HI for the low-risk PTV (PTV2). Concerning the OAR sparing, the VMAT plans demonstrated significantly lower Dmax of the spinal cord (planning OAR volume, PRV) and brainstem (PRV), as well as lower Dmean and V30Gy of the right parotid. No significant differences were observed between the two plans concerning the doses delivered to the thyroid, carotid, oral cavity and left parotid. Moreover, the VMAT planning (147 ± 18 min) consumed 213% more time than the IMRT planning (48 ± 10 min). The MUs of the VMAT plans (556 ± 52) were 64% less than those of the IMRT plans (1684 ± 409), and the average delivery time (2.1 ± 0.1 min) was 66% less than that of the IMRT plans (6.3 ± 0.7 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve superior target dose distribution and better sparing of the spinal cord, brainstem and right parotid, with less MUs and less delivery time. It is recommended for the radiotherapy of locally advanced laryngeal carcinoma.

  18. SU-E-T-808: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Early-Stage Nasopharyngeal Carcinoma: A Dosimetric Study

    International Nuclear Information System (INIS)

    Lu, J-Y; Huang, B-T; Zhang, W-Z

    2015-01-01

    Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for early-stage nasopharyngeal carcinoma. Methods: CT datasets of ten patients with early-stage nasopharyngeal carcinoma were included. Dual-arc VMAT and nine-field IMRT plans were generated for each case, and were then compared in terms of planning-target-volume (PTV) coverage, conformity index (CI) and homogeneity index (HI), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided comparable HI and CI of PTVnx (PTV of primary tumor of nasopharynx), superior CI and inferior HI of PTVnd (PTV of lymph nodes), as well as superior CI and comparable HI of PTV60 (high-risk PTV). The VMAT plans provided better sparing of the spinal cord, oral cavity and normal tissue, but inferior sparing of the brainstem planning OAR volume (PRV), larynx and parotids, as well as comparable sparing of the spinal cord PRV, brainstem, lenses, optic nerves, optic chiasm. Moreover, the average planning time (181.6 ± 36.0 min) for the VMAT plans was 171% more than that of the IMRT plans (68.1 ± 7.6 min). The MUs of the VMAT plans (609 ± 43) were 70% lower than those of the IMRT plans (2071 ± 262), while the average delivery time (2.2 ± 0.1 min) was 66% less than that of the IMRT plans (6.6 ± 0.4 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve similar or slightly superior target dose distribution, with no significant advantages on OAR sparing, and it can achieve significant reductions of MUs and delivery time

  19. The evaluation of properties for radiation therapy techniques with flattening filter-free beam and usefulness of time and economy to a patient with the radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Jang Hyeon; Won, Hui Su; Hong, Joo Wan; Chang, Nam Jun; Park, Jin Hong [Dept. of Radiation Oncology, Seoul national university Bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    The aim of this study was to appraise properties for radiation therapy techniques and effectiveness of time and economy to a patient in the case of applying flattening filter-free (3F) and flattening filter (2F) beam to the radiation therapy. Alderson rando phantom was scanned for computed tomography image. Treatment plans for intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and stereotactic body radiation therapy (SBRT) with 3F and 2F beam were designed for prostate cancer. To evaluate the differences between the 3F and 2F beam, total monitor units (MUs), beam on time (BOT) and gantry rotation time (GRT) were used and measured with TrueBeam{sup TM} STx and Surveillance And Measurement (SAM) 940 detector was used for photoneutron emitted by using 3F and 2F. To assess temporal and economical aspect for a patient, total treatment periods and medical fees were estimated. In using 3F beam, total MUs in IMRT plan increased the highest up to 34.0% and in the test of BOT, GRT and photoneutron, the values in SBRT plan decreased the lowest 39.8, 38.6 and 48.1%, respectively. In the temporal and economical aspect, there were no differences between 3F and 2F beam in all of plans and the results showed that 10 days and 169,560 won was lowest in SBRT plan. According as the results, total MUs increased by using 3F beam than 2F beam but BOT, GRT and photoneutron decreased. From above the results, using 3F beam can decrease intra-fraction setup error and risk of radiation-induced secondary malignancy. But, using 3F beam did not make the benefits of temporal and economical aspect for a patient with the radiation therapy.

  20. 24 CFR 108.20 - Monitoring office responsibility for monitoring plans and reports.

    Science.gov (United States)

    2010-04-01

    ... documenting the implementation of the AFHM plan, including sales or rental reports, as required by the.... When sales or rental reports show that 20% of the units covered by the AFHM plan have been sold or... for monitoring plans and reports. 108.20 Section 108.20 Housing and Urban Development Regulations...

  1. Spatial distribution of motor units recruited during electrical stimulation of the quadriceps muscle versus the femoral nerve.

    Science.gov (United States)

    Rodriguez-Falces, Javier; Maffiuletti, Nicola A; Place, Nicolas

    2013-11-01

    In this study we investigated differences in the spatial recruitment of motor units (MUs) in the quadriceps when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. M-waves and mechanical twitches were evoked using over-the-quadriceps and femoral nerve stimulation of gradually increasing intensity from 22 young, healthy subjects. Spatial recruitment was investigated using recruitment curves of M-waves recorded from the vastus medialis (VM) and vastus lateralis (VL) and of twitches recorded from the quadriceps. At maximal stimulation intensity (Imax), no differences were found between nerve and over-the-quadriceps stimulation. At submaximal intensities, VL M-wave amplitude was higher for over-the-quadriceps stimulation at 40% Imax, and peak twitch force was greater for nerve stimulation at 60% and 80% Imax. For the VM, MU spatial recruitment during nerve and over-the-quadriceps stimulation of increasing intensity occurred in a similar manner, whereas significant differences were observed for the VL. Copyright © 2013 Wiley Periodicals, Inc.

  2. SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

    Energy Technology Data Exchange (ETDEWEB)

    Chung, J; Kim, J [Seoul National University Bundang Hospital, Seongnam, Kyeonggi-do (Korea, Republic of); Lee, J [Konkuk University Medical Center, Seoul, Seoul (Korea, Republic of); Kim, Y [Choonhae College of Health Sciences, Ulsan (Korea, Republic of)

    2014-06-01

    Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest.

  3. SU-E-T-131: Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam

    International Nuclear Information System (INIS)

    Chung, J; Kim, J; Lee, J; Kim, Y

    2014-01-01

    Purpose: The present study aimed to investigate the dosimetric impacts of the anisotropic analytic algorithm (AAA) and the Acuros XB (AXB) plan for lung stereotactic ablative radiation therapy using flattening filter-free (FFF) beam. We retrospectively analyzed 10 patients. Methods: We retrospectively analyzed 10 patients. The dosimetric parameters for the target and organs at risk (OARs) from the treatment plans calculated with these dose calculation algorithms were compared. The technical parameters, such as the computation times and the total monitor units (MUs), were also evaluated. Results: A comparison of DVHs from AXB and AAA showed that the AXB plan produced a high maximum PTV dose by average 4.40% with a statistical significance but slightly lower mean PTV dose by average 5.20% compared to the AAA plans. The maximum dose to the lung was slightly higher in the AXB compared to the AAA. For both algorithms, the values of V5, V10 and V20 for ipsilateral lung were higher in the AXB plan more than those of AAA. However, these parameters for contralateral lung were comparable. The differences of maximum dose for the spinal cord and heart were also small. The computation time of AXB was found fast with the relative difference of 13.7% than those of AAA. The average of monitor units (MUs) for all patients was higher in AXB plans than in the AAA plans. These results indicated that the difference between AXB and AAA are large in heterogeneous region with low density. Conclusion: The AXB provided the advantages such as the accuracy of calculations and the reduction of the computation time in lung stereotactic ablative radiotherapy (SABR) with using FFF beam, especially for VMAT planning. In dose calculation with the media of different density, therefore, the careful attention should be taken regarding the impacts of different heterogeneity correction algorithms. The authors report no conflicts of interest

  4. Development of a mobile cord-monitoring unit (CMU) for steel cord conveyor belts of RWE Power AG; Entwicklung einer mobilen Zugtraeger-Ueberwachungs-Einrichtung (ZTUe) an Stahlseilfoerdergurten der RWE Power AG

    Energy Technology Data Exchange (ETDEWEB)

    Ebel, Max-Peter Benjamin [RWE Power AG, Technikzentrum Tagebau, Frechen (Germany)

    2009-07-15

    We have succeeded in developing a mobile measuring system suitable for everyday use that has already proven its practical suitability in a wide range of measurements. At present, we are preparing the stationary and permanent installation of aluminium supporting beams in the various conveyor drive stations. Thus, outages for the temporary installation of the supporting beam, which were still few, would no longer be required and the ''measuring crew'' would only have to carry around the handy measurement case and laptop. This considerably simpler application and the positive feedback on the benefits of the system are the main reasons why we will not work on the development of a stationary online system. The remaining additional benefit of such a unit would only be of minor significance. We are currently planning the following additional development steps as far as the ''mobile cord-monitoring unit'' is concerned: Developing a sensor-based belt edge monitoring unit as a modular complement to the system. This unit will monitor both belt edges by means of sensors, record them in the measuring signal and represent them explicitly in the evaluation. Linking the CMU evaluation software with the RegGEA system mentioned in Chapter 7, which has been introduced at RWE Power. This step combines an advanced central maintenance and planning system with an innovative belt damage detection system in a single piece of peripheral equipment, which offers the user much more advantages than the sum of the two individual systems taken alone would have done. Designing an aluminium supporting beam divisible into individual segments. Its handy pallet dimensions will allow the complete system to be transported to any site outside of RWE Power. Even though the system was originally conceived as a development for RWE Power, it has already met with great interest outside of RWE Power AG. (orig.)

  5. Environmental Monitoring Plan United States Department of Energy Richland Operations Office. Revision 2

    International Nuclear Information System (INIS)

    1997-01-01

    This Environmental Monitoring Plan was prepared for the US Department of Energy's (DOE's) Richland Operations Office (RL) to implement the requirements of DOE Order 5400.1. According to the Order, each DOE site, facility, or activity that uses, generates, releases, or manages significant pollutants or hazardous materials shall prepare a written environmental monitoring plan covering two major activities: (1) effluent monitoring and (2) environmental surveillance. The plan is to contain information discussing the rationale and design criteria for the monitoring programs, sampling locations and schedules, quality assurance requirements, program implementation procedures, analytical procedures, and reporting requirements. The plan's purpose is to assist DOE in the management of environmental activities at the Hanford Site and to help ensure that operations on the site are conducted in an environmentally safe and sound manner

  6. Environmental Monitoring Plan United States Department of Energy Richland Operations Office. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-10

    This Environmental Monitoring Plan was prepared for the US Department of Energy`s (DOE`s) Richland Operations Office (RL) to implement the requirements of DOE Order 5400.1. According to the Order, each DOE site, facility, or activity that uses, generates, releases, or manages significant pollutants or hazardous materials shall prepare a written environmental monitoring plan covering two major activities: (1) effluent monitoring and (2) environmental surveillance. The plan is to contain information discussing the rationale and design criteria for the monitoring programs, sampling locations and schedules, quality assurance requirements, program implementation procedures, analytical procedures, and reporting requirements. The plan`s purpose is to assist DOE in the management of environmental activities at the Hanford Site and to help ensure that operations on the site are conducted in an environmentally safe and sound manner.

  7. KOLONISASI Mus musculus albino DI LABORATORIUM LOKA LITBANG P2B2 BANJARNEGARA

    Directory of Open Access Journals (Sweden)

    Dewi Marbawati

    2012-11-01

    Full Text Available The improvement and development of science and technologycal in health area must be followed with improvement of requirement of test animal would especially white mouse (Mus musculus albino/mencit. Usage of white mouse (mencit because of relatively easy in handling, the size relatively small, the price relatively cheap, once birth can reach 16- 18, have similiarity in circulation system of human and doesn't have ability to vomit because having spillway in bouncing up, that is why white mouse used for drug trial research. This research expected to obtain stable white mouse colony in laboratory to fulfill requirement of white mouse as subject for research.Research was started in March-November 2008 in Loka Litbang P2B2 Banjarnegara. This research was elementary research with observational design. Data were collected from white mouse growth observation. Result of observation showed reproduction of white mouse after 5 month, from 6 white mouse increased become 17 (increased 2 times more, with number of deaths 11,76%. This white mouse survive until 12 months, but the average was 6 month. Oldest mencit until research ends (November 2008 ranges from 8 months. Daily observation data showed that white mouse can bear children until 6/pregnance. According to literature study mouse can bear children average 68/pregnance. Generaly baby mouse was around 1 gram, heavily horns depend on type (strain of white mouse. Result of white mouse weight showed increase of white mouse's body weight every 2 weeks was 8,6 grams. Observation data of development white mouse showed after 4 days the white mouse hair was seen, specially moustache that was clearly seen, on 5 day whole body was white. At the age of 10 days ear opened, part of other body like external mamilla and genitals become explains looked to be. At the age of 12 days eye started opens and active walking.

  8. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1982

    International Nuclear Information System (INIS)

    Black, S.C.; Grossman, R.F.; Mullen, A.A.; Potter, G.D.; Smith, D.D.

    1983-07-01

    A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify trends, and to provide information to the public. This report summarizes these activities for CY 1982

  9. High-stable secondary-emission monitor for accelerated electron beam current

    International Nuclear Information System (INIS)

    Prudnikov, I.A.; Saksaganskij, G.L.; Bazhanov, E.B.; Zabrodin, B.V.

    1977-01-01

    A secondary-emission monitor for a 10 to 30 MeV electron beam (beam current is 10 -4 to 10 -2 A) is described. The monitor comprises a measuring electrode unit, titanium discharge-type pump, getter made of porous titanium, all enclosed in a metal casing. The measuring unit comprises three electrodes made of 20 μm aluminium foil. The secondary emission coefficient (5.19%+-0.06% for the electron energy of 20 MeV) is maintained stable for a long time. The monitor detects pulses of up to some nanoseconds duration. It is reliable in operation, and is recommended for a wide practical application

  10. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  11. POST CLOSURE INSPECTION AND MONITORING REPORT FOR CORRECTIVE ACTION UNIT 417: CENTRAL NEVADA TEST AREA - SURFACE, HOT CREEK VALLEY, NEVADA, FOR CALENDAR YEAR 2004

    Energy Technology Data Exchange (ETDEWEB)

    BECHTEL NEVADA; NNSA NEVADA SITE OFFICE

    2005-04-01

    This post-closure inspection and monitoring report has been prepared according to the stipulations laid out in the Closure Report (CR) for Corrective Action Unit (CAU) 417, Central Nevada Test Area (CNTA)--Surface (U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office [NNSA/NV], 2001), and the Federal Facility Agreement and Consent Order (FFACO, 1996). This report provides an analysis and summary of site inspections, subsidence surveys, meteorological information, and soil moisture monitoring data for CAU 417, which is located in Hot Creek Valley, Nye County, Nevada. This report covers Calendar Year 2004. Inspections at CAU 417 are conducted quarterly to document the physical condition of the UC-1, UC-3, and UC-4 soil covers, monuments, signs, fencing, and use restricted areas. The physical condition of fencing, monuments, and signs is noted, and any unusual conditions that could impact the integrity of the covers are reported. The objective of the soil moisture monitoring program is to monitor the stability of soil moisture conditions within the upper 1.2 meters (m) (4 feet [ft]) of the UC-1 Central Mud Pit (CMP) cover and detect changes that may be indicative of moisture movement exceeding the cover design performance expectations.

  12. The potential of biosensor technology in clinical monitoring and experimental research

    NARCIS (Netherlands)

    Leegsma-Vogt, G; Rhemrev-Boom, MM; Tiessen, RG; Venema, K; Korf, J

    2004-01-01

    Glucose or lactate biosensors are very useful for monitoring metabolism. Continuous monitoring of glucose is for example very important in diabetic patients. The measurement of lactate, a marker for oxygen deficiency, is used in the intensive care unit to monitor the patients' condition. In our

  13. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; GUPPY,J.G.

    1998-09-01

    This is the final report on the INSP project entitled, ``Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant.

  14. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    International Nuclear Information System (INIS)

    GREENE, G.A.; GUPPY, J.G.

    1998-01-01

    This is the final report on the INSP project entitled, ''Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant

  15. [Monitoring evaluation system for high-specialty hospitals].

    Science.gov (United States)

    Fajardo Dolci, Germán; Aguirre Gas, Héctor G; Robledo Galván, Héctor

    2011-01-01

    Hospital evaluation is a fundamental process to identify medical units' objective compliance, to analyze efficiency of resource use and allocation, institutional values and mission alignment, patient safety and quality standards, contributions to research and medical education, and the degree of coordination among medical units and the health system as a whole. We propose an evaluation system for highly specialized regional hospitals through the monitoring of performance indicators. The following are established as base thematic elements in the construction of indicators: safe facilities and equipment, financial situation, human resources management, policy management, organizational climate, clinical activity, quality and patient safety, continuity of care, patients' and providers' rights and obligations, teaching, research, social responsibility, coordination mechanisms. Monitoring refers to the planned and systematic evaluation of valid and reliable indicators, aimed at identifying problems and opportunity areas. Moreover, evaluation is a powerful tool to strengthen decision-making and accountability in medical units.

  16. Monitoring And Controlling Hydroponic Flow

    Science.gov (United States)

    Dreschel, Thomas W.

    1992-01-01

    Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.

  17. The influence of the way the muscle force is modeled on the predicted results obtained by solving indeterminate problems for a fast elbow flexion.

    Science.gov (United States)

    Raikova, Rositsa; Aladjov, Hristo

    2003-06-01

    A critical point in models of the human limbs when the aim is to investigate the motor control is the muscle model. More often the mechanical output of a muscle is considered as one musculotendon force that is a design variable in optimization tasks solved predominantly by static optimization. For dynamic conditions, the relationship between the developed force, the length and the contraction velocity of a muscle becomes important and rheological muscle models can be incorporated in the optimization tasks. Here the muscle activation can be a design variable as well. Recently a new muscle model was proposed. A muscle is considered as a mixture of motor units (MUs) with different peculiarities and the muscle force is calculated as a sum of the MUs twitches. The aim of the paper is to compare these three ways for presenting the muscle force. Fast elbow flexion is investigated using a planar model with five muscles. It is concluded that the rheological models are suitable for calculation of the current maximal muscle forces that can be used as weight factors in the objective functions. The model based on MUs has many advantages for precise investigations of motor control. Such muscle presentation can explain the muscle co-contraction and the role of the fast and the slow MUs. The relationship between the MUs activation and the mechanical output is more clear and closer to the reality.

  18. A survey on helminthic infection in mice (Mus musculus and rats (Rattus norvegicus and Rattus rattus in Kermanshah, Iran

    Directory of Open Access Journals (Sweden)

    Norollah Pakdel

    2013-06-01

    Full Text Available Parasitic infections of rodents can compromise scientific research as well as the health of the animals and humans. Based on previous studies, infection rate of parasitic helminths is different in various regions of Iran. The current survey was aimed to determine endoparasitic helminths infection in 138 trapped rodents of Kermanshah county, Iran. Mice and rats were trapped using metal snares from January to October 2011 and euthanized. Rodents included 110 Mus musculus (79.00%, 23 Rattus norvegicus (17.00%, and five Rattus rattus (4.00%. The gastrointestinal and respiratory tracts were removed and examined to identify parasitic helminths. The results indicated that 42.02% of examined rodents were infected with eight helminths species, i.e. Trichuris muris (14.49%, Syphacia obvelata (13.76%, Syphacia muris (2.89%, Aspicularis tetrapetra (5.07%, Heterakis spumosa (5.07%, Capillaria hepatica eggs (3.62%, Hyminolepis diminuta (12.30%, and Cystisercus fasciolaris, the larva of Taenia teanieformis (4.34%. Given the results of this study, we concluded that examined rodents were more infected with nematodes than other helminths. As rodents are usually infected with a number of zoonotic parasites, hence control of these animals has an important role in safeguarding public health.

  19. On the tear proteome of the house mouse (Mus musculus musculus in relation to chemical signalling

    Directory of Open Access Journals (Sweden)

    Romana Stopkova

    2017-07-01

    Full Text Available Mammalian tears are produced by lacrimal glands to protect eyes and may function in chemical communication and immunity. Recent studies on the house mouse chemical signalling revealed that major urinary proteins (MUPs are not individually unique in Mus musculus musculus. This fact stimulated us to look for other sexually dimorphic proteins that may—in combination with MUPs—contribute to a pool of chemical signals in tears. MUPs and other lipocalins including odorant binding proteins (OBPs have the capacity to selectively transport volatile organic compounds (VOCs in their eight-stranded beta barrel, thus we have generated the tear proteome of the house mouse to detect a wider pool of proteins that may be involved in chemical signalling. We have detected significant male-biased (7.8% and female-biased (7% proteins in tears. Those proteins that showed the most elevated sexual dimorphisms were highly expressed and belong to MUP, OBP, ESP (i.e., exocrine gland-secreted peptides, and SCGB/ABP (i.e., secretoglobin families. Thus, tears may have the potential to elicit sex-specific signals in combination by different proteins. Some tear lipocalins are not sexually dimorphic—with MUP20/darcin and OBP6 being good examples—and because all proteins may flow with tears through nasolacrimal ducts to nasal and oral cavities we suggest that their roles are wider than originally thought. Also, we have also detected several sexually dimorphic bactericidal proteins, thus further supporting an idea that males and females may have adopted alternative strategies in controlling microbiota thus yielding different VOC profiles.

  20. Development and implementation of a software for assessment of calculations in radiotherapy monitor units; Elaboracao e implementacao de um programa para verificacao dos calculos das unidades monitoras em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Marcio Rogerio; Silva, Marco Antonio da; Rodrigues, Laura Natal [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Servico de Radioterapia]. E-mail: mrmuller@usp.br

    2005-12-01

    Objective: To develop and implement a software based on the manual calculation algorithm for verification of the calculations in radiotherapy monitor units and to establish acceptance levels as a mechanism of quality assurance. Materials and methods: Data were obtained from Clinac 600C and 2100C Varian linear accelerators and the computerized treatment planning system used was CadPlan{sup TM}. Results: For the 6 MV beams the acceptance levels for deviations among the calculations of monitor units, divided by treatment area, were the following: breast (0.0%{+-}1.7%), head and neck (1.5%{+-}0.5%), hypophysis (-1.7%{+-}0.5%), pelvis (2.1%{+-}2.1%) and thorax (0.2%{+-}1.3%). For the 15 MV beams the suggested level for pelvis in all the treatment techniques was (3.2%{+-}1.3%). Conclusion: The present data are sufficient to justify the use of the software in the clinical practice as a tool for the quality assurance program. (author)