WorldWideScience

Sample records for monitor test status

  1. Status of Wakefield Monitor Experiments at the CLIC Test Facility

    CERN Document Server

    Lillestøl, Reidar; Aftab, Namra; Corsini, Roberto; Döbert, Steffen; Farabolini, Wilfrid; Grudiev, Alexej; Javeed, Sumera; Pfingstner, Juergen; Wuensch, Walter

    2016-01-01

    For the very low emittance beams in CLIC, it is vital to mitigate emittance growth which leads to reduced luminosity in the detectors. One factor that leads to emittance growth is transverse wakefields in the accelerating structures. In order to combat this the structures must be aligned with a precision of a few um. For achieving this tolerance, accelerating structures are equipped with wakefield monitors that measure higher-order dipole modes excited by the beam when offset from the structure axis. We report on such measurements, performed using prototype CLIC accelerating structures which are part of the module installed in the CLIC Test Facility 3 (CTF3) at CERN. Measurements with and without the drive beam that feeds rf power to the structures are compared. Improvements to the experimental setup are discussed, and finally remaining measurements that should be performed before the completion of the program are summarized.

  2. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  3. Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.

    Directory of Open Access Journals (Sweden)

    Ioana Nicolau

    Full Text Available BACKGROUND: Poor adherence to isoniazid (INH preventive therapy (IPT is an impediment to effective control of latent tuberculosis (TB infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK, two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. METHODOLOGY/PRINCIPAL FINDINGS: 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2 and specificity of 98.7% (94.8, 99.8. IsoScreen had intra-rater agreement (kappa of 0.75 (0.48, 0.94 and inter-rater agreement of 0.61 (0.27, 0.90. SmokeScreen had a sensitivity of 69.2% (56.4, 79.8, specificity of 81.6% (73.0, 88.0, intra-rater agreement of 0.77 (0.56, 0.94, and inter-rater agreement of 0.66 (0.42, 0.88. False-positive SmokeScreen tests were strongly associated with INH treatment. CONCLUSIONS: IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive Smoke

  4. Detection of acute deterioration in health status visit among COPD patients by monitoring COPD assessment test score

    Directory of Open Access Journals (Sweden)

    Pothirat C

    2015-02-01

    Full Text Available Chaicharn Pothirat, Warawut Chaiwong, Atikun Limsukon, Athavudh Deesomchok, Chalerm Liwsrisakun, Chaiwat Bumroongkit, Theerakorn Theerakittikul, Nittaya PhetsukDivision of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, ThailandBackground: The Chronic Obstructive Pulmonary Disease Assessment Test (CAT could play a role in detecting acute deterioration in health status during monitoring visits in routine clinical practice.Objective: To evaluate the discriminative property of a change in CAT score from a stable baseline visit for detecting acute deterioration in health status visits of chronic obstructive pulmonary disease (COPD patients.Methods: The CAT questionnaire was administered to stable COPD patients routinely attending the chest clinic of Chiang Mai University Hospital who were monitored using the CAT score every 1–3 months for 15 months. Acute deterioration in health status was defined as worsening or exacerbation. CAT scores at baseline, and subsequent visits with acute deterioration in health status were analyzed using the t-test. The receiver operating characteristic curve was performed to evaluate the discriminative property of change in CAT score for detecting acute deterioration during a health status visit.Results: A total of 354 follow-up visits were made by 140 patients, aged 71.1±8.4 years, with a forced expiratory volume in 1 second of 47.49%±18.2% predicted, who were monitored for 15 months. The mean CAT score change between stable baseline visits, by patients’ and physicians’ global assessments, were 0.05 (95% confidence interval [CI], -0.37–0.46 and 0.18 (95% CI, -0.23–0.60, respectively. At worsening visits, as assessed by patients, there was significant increase in CAT score (6.07; 95% CI, 4.95–7.19. There were also significant increases in CAT scores at visits with mild and moderate exacerbation (5.51 [95% CI, 4.39–6

  5. Status of the flora and fauna on the Nevada Test Site, 1992. Results of continuing basic environmental monitoring, January through December 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1994-03-01

    This report documents changes in the populations of plants and animals on the Nevada Test Site (NTS) for calendar year 1992. It is part of a Department of Energy (DOE) program (Basic Environmental Compliance and Monitoring Program -- BECAMP) that also includes monitoring DOE compliance with the Endangered Species Act, the Historic Preservation Act, and the American Indian Freedom of Religion Act. Ecological studies were to comply with the National Environmental Policy Act and DOE Order 5400.1, ``General Environmental Protection Program.`` These studies focused on the following: status of ephemeral plants on the Nevada Test Site, 1992; status of reptile and amphibian populations on the Nevada Test Site, 1992; trends in small mammal populations on the Nevada Test Site, 1992; status of large mammals and birds at Nevada Test Site, 1992; and status of perennial plants on the Nevada Test Site, 1992.

  6. Status and test report on the LANL-Boeing APLE/HPO flying-wire beam-profile monitor. Status report

    Energy Technology Data Exchange (ETDEWEB)

    Wilke, M.; Barlow, D.; Fortgang, C.; Gilpatrick, J.; Meyer, R.; Rendon, A.; Warren, D. [Los Alamos National Lab., NM (United States); Greegor, R. [Boeing Co., Seattle, WA (United States)

    1994-07-01

    The High-Power Oscillator (HPO) demonstration of the Average Power Laser Experiment (APLE) is a collaboration by Los Alamos National Laboratory and Boeing to demonstrate a 10 kW average power, 10 {mu}m free electron laser (FEL). As part of the collaboration, Los Alamos National Laboratory (LANL) is responsible for many of the electron beam diagnostics in the linac, transport, and laser sections. Because of the high duty factor and power of the electron beam, special diagnostics are required. This report describes the flying wire diagnostic required to monitor the beam profile during high-power, high-duty operation. The authors describe the diagnostic and prototype tests on the Los Alamos APLE Prototype Experiment (APEX) FEL. They also describe the current status of the flying wires being built for APLE.

  7. Advanced Subsystems Status Monitor.

    Science.gov (United States)

    1980-04-01

    algorithms in a fashion analogous to human learning , by monitoring the consistency and effec- tiveness of the human operator’s responses. In view of...ou ill t wX Converer O~t~t133 Itectite.-Ot TABLE 16. CONTINUED. PAIM4(IN PSIONIIS MISSION PHASE ENVIROMENT OISPLAV FOWtAl ram AC toad Meter ff DC toad...annoying, or distracting during NOE flight? Eng./X4SN instnuments in new A/C. f, , tic marks difficult and time consuming to Interpret. Electrical

  8. Status on contamination monitoring in China

    Energy Technology Data Exchange (ETDEWEB)

    Gou Quanlu [China Institute for Radiation Protection, Taiyuan (China)

    1997-06-01

    The air contaminated by radioactive materials in nuclear enterprises and radioactive workplaces and forming radioactive aerosol and the leakage of radioactive materials in operation cause internal exposure damage in workers. It is necessary and important to monitor air and surface contaminations for the health of public and workers, and for protecting environment. At present, many institutes engage in the studies on surface contamination monitoring in China, and the government has formulated the control limits of surface contamination in the Regulations of Radiation Protection. The monitors for surface contamination monitoring are almost home-made. The methods being used often are smear test and placing surface sample test. Scintillation counters, semiconductor detectors and G-M counters have been used for detecting alpha surface contamination. Plastic scintillator meters and thin wall/window G-M counters are used for beta surface contamination. Special detectors have been designed for monitoring low energy nuclides. The status of airborne contamination monitoring in China is reported. As the studies for future, the development of the surface contamination monitor for low energy beta nuclides, especially H-3, the monitoring methods for the special shapes of surfaces, the technology of decontamination and the calibration method and device for on-line radioactive aerosol continuous monitors are taken up. (K.I.)

  9. TESLA Test Facility. Status

    Energy Technology Data Exchange (ETDEWEB)

    Aune, B. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); TESLA Collaboration

    1996-01-01

    The TESLA Test Facility (TTF), under construction at DESY by an international collaboration, is an R and D test bed for the superconducting option for future linear e+/e-colliders. It consists of an infrastructure to process and test the cavities and of a 500 MeV linac. The infrastructure has been installed and is fully operational. It includes a complex of clean rooms, an ultra-clean water plant, a chemical etching installation and an ultra-high vacuum furnace. The linac will consist of four cryo-modules, each containing eight 1 meter long nine-cell cavities operated at 1.3 GHz. The base accelerating field is 15 MV/m. A first injector will deliver a low charge per bunch beam, with the full average current (8 mA in pulses of 800 {mu}s). A more powerful injector based on RF gun technology will ultimately deliver a beam with high charge and low emittance to allow measurements necessary to qualify the TESLA option and to demonstrate the possibility of operating a free electron laser based on the Self-Amplified-Spontaneous-Emission principle. Overview and status of the facility will be given. Plans for the future use of the linac are presented. (R.P.). 19 refs.

  10. Human Factors Evaluation of the Hidalgo Equivital EQ-02 Physiological Status Monitoring System

    Science.gov (United States)

    2013-10-11

    Equivital™ EQ-02 physiological status monitoring ( PSM ) system. The usability and acceptability of this system has been tested previously and generally...under CBRNE- PPE provided utility and was comfortable to wear. Thermal strain; CBRNE; PPE; physiological status monitoring; PSM ; human factors; chem...real-time physiological monitoring. The Hidalgo, Ltd. (Cambridge, UK) Equivital™ EQ-02 physiological status monitoring ( PSM ) system is a typical

  11. Status of the flora and fauna on the Nevada Test Site, 1988. Results of continuing basic environmental monitoring, January--December 1988

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1992-06-01

    In 1987 the US Department of Energy (DOE) initiated a program to monitor the health of the Nevada Test Site (NTS) plants and animals in support of the National Environmental Protection Act. The program, part of DOE`s Basic Environmental Compliance and Monitoring Program (BECAMP), monitors perennial and ephemeral plants, the more common species of rodents and lizards, and the horses, deer, raptors and other large animals on the NTS. This is a report of data collected on these flora and fauna for the year 1988, the second year of monitoring.

  12. Status of the flora and fauna on the Nevada Test Site, 1994: Results of continuing Basic Environmental Monitoring January through December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1995-09-01

    This is the final progress report of a Department of Energy (DOE), Nevada operations Office (NV), program to monitor the ecology of the Nevada Test Site (NTS). The eight-year Basic Environmental Compliance and Monitoring Program (BECAMP) included meeting goals of understanding the spatial and temporal changes of plants and animals on the NTS, and determining the effects of DOE operations on those plants and animals. Determination of the changes was addressed through monitoring the most common plant and animal species at undisturbed (baseline) plots located in the major NTS valleys and mesas. One plot in Yucca Flat, the site of most nuclear weapons tests, was monitored annually, while other baseline plots were censused on a three- or four-year cycle. Effects of DOE operations were examined at sites of major disturbances, related to both DOE operations and natural disturbance mechanisms, censused on a three-year cycle. This report concentrates on work completed in 1994.

  13. Physiologic Status Monitoring via the Gastrointestinal Tract.

    Science.gov (United States)

    Traverso, G; Ciccarelli, G; Schwartz, S; Hughes, T; Boettcher, T; Barman, R; Langer, R; Swiston, A

    2015-01-01

    Reliable, real-time heart and respiratory rates are key vital signs used in evaluating the physiological status in many clinical and non-clinical settings. Measuring these vital signs generally requires superficial attachment of physically or logistically obtrusive sensors to subjects that may result in skin irritation or adversely influence subject performance. Given the broad acceptance of ingestible electronics, we developed an approach that enables vital sign monitoring internally from the gastrointestinal tract. Here we report initial proof-of-concept large animal (porcine) experiments and a robust processing algorithm that demonstrates the feasibility of this approach. Implementing vital sign monitoring as a stand-alone technology or in conjunction with other ingestible devices has the capacity to significantly aid telemedicine, optimize performance monitoring of athletes, military service members, and first-responders, as well as provide a facile method for rapid clinical evaluation and triage.

  14. The need for monitoring metabolic status

    Science.gov (United States)

    Vanderveen, John E.

    2005-05-01

    Modern military operations utilize complex technologies that require high levels of readiness and sustained cognitive and physical performance of combat military combat personnel. These military operations often depend on weapon systems that use advanced computer technology coupled with an array of sensors that provide continuous information on the battlefield environment and on equipment function. However there is a lack of real-time information on status of the personnel who control these systems and who are vital to mission success. Failure of the human element renders the weapon system useless so it is important to know if an individual is physically and cognitively fit to perform his or her task. Based on the premise that status of metabolic processes provide an early indication of a change in an individuals physiological status, monitoring of selective biomarkers of metabolism and organ function can provide insight on the individual"s ability to perform mission tasks. During combat individuals may not be aware that they have reached a compromised physiological condition due to dehydration, physical exertion, stress, fatigue, sleep deprivation, exposure to toxins or other condition that may affect physical and cognitive performance and health. Systems that can provide the individual or his or her commander with information about significant changes in one or more metabolic functions could permit timely intervention to correct the condition. In the event that serious injury has already occurred to an individual, metabolic monitoring can provide valuable intelligence needed for decisions on achieving mission objectives.

  15. Status of the flora and fauna on the Nevada Test Site, 1993. Results of continuing basic environmental monitoring, January through December 1993

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1994-09-01

    This report provides the results of monitoring of plants and animals on the Nevada Test Site during calendar year 1993. Monitoring was accomplished under the Department of Energy`s Basic Environmental Compliance and Monitoring Program, initiated in 1987. The program looks at both baseline study areas, chosen to represent undisturbed conditions as much as possible, and areas disturbed by Department of energy (DOE) activities or natural phenomena. DOE disturbances studied include areas blasted by above-ground nuclear tests before 1962, subsidence craters created by underground nuclear tests, road maintenance activities, areas cleared for drilling, and influences of man-made water sources. Natural phenomena studied include recovery from range fires, effects of introduced species, damage to plants by insect outbreaks, and effects of weather fluctuations. In 1993 disturbances examined included several burned areas and roadsides, a drill pad on Pahute Mesa, introduced grasses and shrub removal effects on ephemeral plants, and effects on pine trees of an infestation of pinyon needle scale insects.

  16. HEART RATE DURING SLEEP: IMPLICATIONS FOR MONITORING TRAINING STATUS

    Directory of Open Access Journals (Sweden)

    Miriam R. Waldeck

    2003-12-01

    Full Text Available Resting heart rate has sometimes been used as a marker of training status. It is reasonable to assume that the relationship between heart rate and training status should be more evident during sleep when extraneous factors that may influence heart rate are reduced. Therefore the aim of the study was to assess the repeatability of monitoring heart rate during sleep when training status remained unchanged, to determine if this measurement had sufficient precision to be used as a marker of training status. The heart rate of ten female subjects was monitored for 24 hours on three occasions over three weeks whilst training status remained unchanged. Average, minimum and maximum heart rate during sleep was calculated. The average heart rate of the group during sleep was similar on each of the three tests (65 ± 9, 63 ± 6 and 67 ± 7 beats·min-1 respectively. The range in minimum heart rate variation during sleep for all subjects over the three testing sessions was from 0 to 10 beats·min-1 (mean = 5 ± 3 beats·min-1 and for maximum heart rate variation was 2 to 31 beats·min-1 (mean = 13 ± 9 beats·min-1. In summary it was found that on an individual basis the minimum heart rate during sleep varied by about 8 beats·min-1. This amount of intrinsic day-to-day variation needs to be considered when changes in heart rate that may occur with changes in training status are interpreted

  17. Application of fuzzy logic in automated cow status monitoring.

    Science.gov (United States)

    de Mol, R M; Woldt, W E

    2001-02-01

    Sensors that measure yield, temperature, electrical conductivity of milk, and animal activity can be used for automated cow status monitoring. The occurrence of false-positive alerts, generated by a detection model, creates problems in practice. We used fuzzy logic to classify mastitis and estrus alerts; our objective was to reduce the number of false-positive alerts and not to change the level of detected cases of mastitis and estrus. Inputs for the fuzzy logic model were alerts from the detection model and additional information, such as the reproductive status. The output was a classification, true or false, of each alert. Only alerts that were classified true should be presented to the herd manager. Additional information was used to check whether deviating sensor measurements were caused by mastitis or estrus, or by other influences. A fuzzy logic model for the classification of mastitis alerts was tested on a data set from cows milked in an automatic milking system. All clinical cases without measurement errors were classified correctly. The number of false-positive alerts over time from a subset of 25 cows was reduced from 1266 to 64 by applying the fuzzy logic model. A fuzzy logic model for the classification of estrus alerts was tested on two data sets. The number of detected cases decreased slightly after classification, and the number of false-positive alerts decreased considerably. Classification by a fuzzy logic model proved to be very useful in increasing the applicability of automated cow status monitoring.

  18. Comparative testing of slurry monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hylton, T.D.; Bayne, C.K. [Oak Ridge National Lab., TN (United States); Anderson, M.S. [Ames Lab., IA (United States); Van Essen, D.C. [Advanced Integrated Management Services, Inc., Oak Ridge, TN (United States)

    1998-05-01

    The US Department of Energy (DOE) has millions of gallons of radioactive liquid and sludge wastes that must be retrieved from underground storage tanks, transferred to treatment facilities, and processed to a final waste form. The wastes will be removed from the current storage tanks by mobilizing the sludge wastes and mixing them with the liquid wastes to create slurries. Each slurry would then be transferred by pipeline to the desired destination. To reduce the risk of plugging a pipeline, the transport properties (e.g., density, suspended solids concentration, viscosity, particle size range) of the slurry should be determined to be within acceptable limits prior to transfer. These properties should also be monitored and controlled within specified limits while the slurry transfer is in progress. The DOE issued a call for proposals for developing on-line instrumentation to measure the transport properties of slurries. In response to the call for proposals, several researchers submitted proposals and were funded to develop slurry monitoring instruments. These newly developed DOE instruments are currently in the prototype stage. Before the instruments were installed in a radioactive application, the DOE wanted to evaluate them under nonradioactive conditions to determine if they were accurate, reliable, and dependable. The goal of this project was to test the performance of the newly developed DOE instruments along with several commercially available instruments. The baseline method for comparison utilized the results from grab-sample analyses.

  19. The status on contamination monitoring in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sinakhom, Fookiat [Office of Atomic Energy for Peace, Bangkok (Thailand)

    1997-06-01

    Thailand has embarked upon the development of nuclear energy for peaceful utilizations since 1961 when the Atomic Energy for Peace Act was enacted. The Atomic Energy Commission (Thai AEC) was established under section 5 of this Act having power and duty of carrying out matters concerning atomic energy for peace. The applications of nuclear energy in Thailand, at present are exclusively in medicine, education, research and industry. In this paper, the following items are described on contamination monitoring: controllable monitoring, uncontrollable monitoring, standardization of monitoring instruments, and decontamination and waste management. (G.K.)

  20. Operator coil monitoring Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Erhart, M.F.

    1995-05-16

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring and control of the Programmable Logic Controller (PLC) abort coils from the Master and RSS stations will be systematically tested during performance of this procedure. It should be noted that these are not physical abort coils but software coils controlled by the software`s ladder logic. The readiness of the DACS to properly interface with the ENRAF wire level gauge installed in the SY-101 storage tank will also be tested. During this test, a verification of all abort coil indications will be conducted at the DACS Development Facility in the 306E Building by injecting an input signal for each DACS sensor that has an associated abort coil until the abort coil actuates, and then ensuring that the status of the abort coil indicated at the Master and RSS stations is correct. Each abort coil will also be tested to ensure that the ``ENABLE`` and ``DISABLE`` controls from the Master and RSS stations function correctly, and only with the use of proper passwords.

  1. French Flight Test Program LEA Status

    Science.gov (United States)

    2010-09-01

    reusable . French Flight Test Program LEA Status RTO-EN-AVT-185 17 - 5 Figure 4: CAD view of LEA vehicle. The test principle consists in...Figure 8: CLEA model under test at ONERA test facility. Some parametric studies related to forebody have been carried out in order to determine a...PROPULSION: ENGINE DESIGN – INTEGRATION AND THERMAL MANAGEMENT” is focused on the French flight experiment program called “LEA”. French R&T effort

  2. Status of contamination monitoring in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Begum, Aleya [Institute of Nuclear Science and Technology, Savar, Dacca (Bangladesh)

    1997-06-01

    The applications of radioisotopes and radiation sources to the research and development in medicine, food agriculture, industries and others are rapidly increasing in Bangladesh. The existing major nuclear facilites and allied laboratories of the country include 3 MW TRIGA Mark-2 research reactor for training, research and radioisotope production, 14 MeV neutron generator for nuclear data measurement and elemental analysis via neutron activation, 3 MeV Van de Graaff accelerator for the research and application of nuclear physics, and 50,000 Ci and 5,000 Ci Co-60 irradiators. About 10 Co-60 and Cs-137 teletherapy units are in operation in hospitals. The radioactive contamination of working areas, equipment, protective clothing and skin may result from normal operation and accidents, and contamination monitoring and decontamination are the essential part of radiation protection program. Surface contamination is monitored with Berthold survey meters. Hand and foot monitors have been used. Routine systematic search, continuous air monitoring, the examination of silt movement in Chittagong harbor using Sc-46 tracer and the measurement of tritium contamination for the neutron generator are reported. (K.I.)

  3. CURRENT STATUS OF INDIVIDUAL DOSIMETRIC MONITORING IN UKRAINE.

    Science.gov (United States)

    Chumak, V; Deniachenko, N; Makarovska, O; Mihailescu, L-C; Prykhodko, A; Voloskyi, V; Vanhavere, F

    2016-09-01

    About 50 000 workers are being occupationally exposed to radiation in Ukraine. Individual dosimetric monitoring (IDM) is provided by 77 dosimetry services and laboratories of very different scale with a number of monitored workers ranging from several persons to ∼9000. In the present work, the current status of personal dosimetry in Ukraine was studied. The First National Intercomparison (FNI) of the IDM labs was accompanied by a survey of the laboratory operation in terms of coverage, types of dosimetry provided, instrumentation and methodologies used, metrological support, data recording, etc. Totally, 34 laboratories responded to the FNI call, and 18 services with 19 different personal dosimetry systems took part in the intercomparison exercise providing 24 dosimeters each for blind irradiation to photons of 6 different qualities (ISO N-series X-rays, S-Cs and S-Co sources) in a dose range of 5-60 mSv. Performance of the dosimetry labs was evaluated according to ISO 14146 criteria of matching trumpet curves with H0 = 0.2 mSv. The test revealed that 8 of the 19 systems meet ISO 14146 criteria in full, 5 other labs show marginal performance and 6 laboratories demonstrated catastrophic quality of dosimetric results. Altogether, 18 participating labs provide dosimetric monitoring to 37 477 workers (about three-fourths of all occupationally exposed workers), usually on monthly (nuclear industry) or quarterly (rest of applications) basis. Of this number, 20 664 persons (55 %) receive completely adequate individual monitoring, and the number of personnel receiving IDM of inadequate quality counts 3054 persons.

  4. Physiologic Status Monitoring via the Gastrointestinal Tract

    Science.gov (United States)

    2015-11-18

    and lungs , we suspect these sites were too distant from the heart and lungs for the sensitivity of the particular microphone chosen (-45dB ±4dB...Monitoring System with Scintigraphy for Measuring Whole Gut Transit. Digestive Diseases and Sciences 54: 2167-2174. 19. Rabiner LR, Schafer RW (2011...chest just above the heart, are also sending data to the A/D converter. The final result is perfectly time-registered data streams for heart and lung

  5. Wide Area Wind Field Monitoring Status & Results

    Energy Technology Data Exchange (ETDEWEB)

    Alan Marchant; Jed Simmons

    2011-09-30

    Volume-scanning elastic has been investigated as a means to derive 3D dynamic wind fields for characterization and monitoring of wind energy sites. An eye-safe volume-scanning lidar system was adapted for volume imaging of aerosol concentrations out to a range of 300m. Reformatting of the lidar data as dynamic volume images was successfully demonstrated. A practical method for deriving 3D wind fields from dynamic volume imagery was identified and demonstrated. However, the natural phenomenology was found to provide insufficient aerosol features for reliable wind sensing. The results of this study may be applicable to wind field measurement using injected aerosol tracers.

  6. NASA/RAE cooperation on a knowlede based flight status monitor

    Science.gov (United States)

    Butler, G. F.; Duke, E. L.

    1989-01-01

    As part of a US/UK cooperative aeronautical research pragram, a joint activity between the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) and the Royal Aerospace Establishment (RAE) on Knowledge Based Systems was established. Under the agreement, a Flight Status Monitor Knowledge base developed at Ames-Dryden was implemented using the real-time IKBS toolkit, MUSE, which was developed in the UK under RAE sponsorship. The Flight Status Monitor is designed to provide on-line aid to the flight test engineer in the interpretation of system health and status by storing expert knowledge of system behavior in an easily accessible form. The background to the cooperation is described and the details of the Flight Status Monitor, the MUSE implementation are presented.

  7. Comparative testing of slurry monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hylton, T.D.; Bayne, C.K. [Oak Ridge National Lab., TN (United States); Anderson, M.S. [Ames Lab., IA (United States); Van Essen, D.C. [Advanced Integrated Management Services, Inc., Oak Ridge, TN (United States)

    1997-12-31

    The U.S. Department of Energy (DOE) has millions of gallons of radioactive liquid and sludge wastes stored in underground tanks. These wastes must be retrieved, transferred to treatment facilities, and processed for disposal. Before removal from the storage tanks, the sludge and liquid wastes will typically be combined to create a mixture of suspended solids, generally referred to as a slurry; the slurry is then pumped from the tank to the treatment facilities by pipelines. Since the wastes are radioactive, it is critically important that the slurries are transported safely and successfully. The consequences of pipeline plugging are unacceptable from the perspectives of schedule, cost, and safety. The baseline method of ensuring that the transport properties of the slurries are correct is to sample the slurry in the tank and analyze the sample in the laboratory. This method has some problems. First, there is a delay between the time that the sample is taken and the time that the analytical results are reported. For some types of analysis, this delay could be from 24 to 48 hours. Second, although the tank is being mixed to keep tile solids in suspension during this period, there is no way to determine whether the contents of the tank are homogenous unless multiple samples are collected at various depths and locations. Therefore, an on-line system that monitors slurry transport properties in real time is needed to evaluate the slurry prior to and during transfer.

  8. Performance, requirements and testing in individual monitoring

    DEFF Research Database (Denmark)

    Julius, H.W.; Christensen, P.; Marshall, T.O.

    1990-01-01

    monitoring, and in particular of those related to the energy and angular dependences of the dosemeters. These data are important for the testing of the dosimetry systems. Finally testing programmes in individual monitoring are discussed and four categories of testing are proposed.......For implementation of the ICRP requirements in practical routine monitoring, a specification is needed with respect to specific performance criteria of the dosimetry system. This includes the dosemeters, and procedures for initial and on-going testing of the dosimetry systems to ensure...... that the specified criteria are continuously met. Methods are here specified for establishing performance criteria, and satisfying the ICRP overall accuracy requirements for individual monitoring. Furthermore, procedures are given for obtaining numerical values of the uncertainties connected with individual...

  9. Forest health monitoring: national status, trends, and analysis 2016

    Science.gov (United States)

    Kevin M. Potter; Barbara L. Conkling

    2017-01-01

    The annual national report of the Forest Health Monitoring (FHM) Program of the Forest Service, U.S. Department of Agriculture, presents forest health status and trends from a national or multi-State regional perspective using a variety of sources, introducesnew techniques for analyzing forest health data, and summarizes results of recently completed...

  10. Client-Server Connection Status Monitoring Using Ajax Push Technology

    Science.gov (United States)

    Lamongie, Julien R.

    2008-01-01

    This paper describes how simple client-server connection status monitoring can be implemented using Ajax (Asynchronous JavaScript and XML), JSF (Java Server Faces) and ICEfaces technologies. This functionality is required for NASA LCS (Launch Control System) displays used in the firing room for the Constellation project. Two separate implementations based on two distinct approaches are detailed and analyzed.

  11. Monitored Geologic Repository Test Evaluation Plan

    Energy Technology Data Exchange (ETDEWEB)

    M.B. Skorska

    2002-01-02

    The Monitored Geologic Repository test & evaluation program will specify tests, demonstrations, examinations, and analyses, and describe procedures to conduct and document testing necessary to verify meeting Monitored Geologic Repository requirements for a safe and effective geologic repository for radioactive waste. This test program will provide assurance that the repository is performing as designed, and that the barriers perform as expected; it will also develop supporting documentation to support the licensing process and to demonstrate compliance with codes, standards, and regulations. This comprehensive program addresses all aspects of verification from the development of test requirements to the performance of tests and reporting of the test results. The ''Monitored Geologic Repository Test & Evaluation Plan'' provides a detailed description of the test program approach necessary to achieve the above test program objectives. This test plan incorporates a set of test phases focused on ensuring repository safety and operational readiness and implements a project-wide integrated product management team approach to facilitate test program planning, analysis, and implementation. The following sections provide a description of the individual test phases, the methodology for test program planning and analyses, and the management approach for implementing these activities.

  12. Monitoring of biogas test plants

    DEFF Research Database (Denmark)

    Holm-Nielsen, Jens Bo; Esbensen, Kim H.

    2011-01-01

    -scale biogas test plant implementation of process analytical technologies (PAT) to develop multivariate calibration/prediction models for anaerobic digestion (AD) processes. A 150 L bioreactor was fitted with a recurrent loop at which NIR spectroscopy and attendant reference sampling were carried out. In all...... NIR spectra to laboratory VFA reference concentrations at the experimental locality Bygholm, it was possible to develop calibration models by partial least squares (PLS) regression, which displayed acceptable to very good prediction performances for total VFA as well as for three other essential...

  13. Test Results of a Phi Monitoring System

    CERN Document Server

    Figueroa, Carlos; Burgos, C; Ferrrando, A; Matorras, Francisco; Molinero, Antonio; Rodriguo, T; Shvachkin, V

    1997-01-01

    The development and tests of a Phi monitoring system prototype designed for the CMS Muon Spectrometer alignment are described. The system, using a sweeping laser beam, defines a light reference plane to be used for the continuous monitoring of the Muon detectors. The performance of the system in the Laboratory was satisfactory. It showed good stability and linearity response behaviour. With the appropriate selection of components it can monitor large range position shifts ( up to 1-2 cm) with good accuracy at long distances ( ~ 60 mu accuracy at 10 m).

  14. Testing integrated sensors for cooperative remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Smith, T.E.; Albano, R.K.; Andersen, M.K. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Lucero, R.L.; Tolk, K.M.; Andrews, N.S. [Sandia National Lab., Albuquerque, NM (United States)

    1996-12-31

    The Modular Integrated Monitoring System (MIMS) program, with Sandia National Laboratory (SNL) as the lead lab, was devised to furnish sensors and integrated multi-sensor systems for cooperative remote monitoring. The Idaho National Engineering Laboratory (INEL), via the Center for Integrated Monitoring and Control (CIMC), provides realistic field tests of the sensors and sensor-integration approach for the MIMS, and for other similar programs. This has two important goals: it helps insure that these systems are truly read for use, and provides a platform so they can be demonstrated for potential users. A remote monitoring test/demonstration has been initiated at the Idaho Chemical Processing Plant (ICPP) to track the movement of spent nuclear fuel from one storage location to another, using a straddle carrier and shielded cask combination. Radiation monitors, motion sensors, videocameras, and other devices from several US Department of Energy (DOE) labs and commercial vendors were linked on the network. Currently, project personnel are collecting raw data from this large array of sensors, without trying to program any special network activities or other responses. These data will be used to determine which devices can actually provide useful information for a cooperative monitoring situation, versus those that may be redundant.

  15. Status of radiation detector and neutron monitor technology

    CERN Document Server

    Kim, Y K; Ha, J H; Han, S H; Hong, S B; Hwang, I K; Lee, W G; Moon, B S; Park, S H; Song, M H

    2002-01-01

    In this report, we describe the current states of the radiation detection technology, detectors for industrial application, and neutron monitors. We also survey the new technologies being applied to this field. The method to detect radiation is the measurement of the observable secondary effect from the interaction between incident radiation and detector material, such as ionization, excitation, fluorescence, and chemical reaction. The radiation detectors can be categorized into gas detectors, scintillation detectors, and semiconductor detectors according to major effects and main applications. This report contains the current status and operational principles of these detectors. The application fields of radiation detectors are industrial measurement system, in-core neutron monitor, medical radiation diagnostic device, nondestructive inspection device, environmental radiation monitoring, cosmic-ray measurement, security system, fundamental science experiment, and radiation measurement standardization. The st...

  16. Implementation of a System for Physiological Status Monitoring by using Tactical Military Networks

    Directory of Open Access Journals (Sweden)

    Goce Stevanoski

    2016-09-01

    Full Text Available E-health sensors are continuing to become more advanced and more reliable in monitoring the human physiological status. There is a continuous scope for improvement in their implementation in different emergency situations. Military organisations can take an advantage of this technology for applying physiological status monitoring on personnel engaged in military operations. This implementation is driven by continuous enhancements of existing communication equipment that produces more data capable radio networks in military environment. Based on these technologies we are proposing system communication architecture for applying real-time physiological status monitoring for personnel engaged in military operations. To examine the proposed architecture, a laboratory testing was performed. The laboratory work included a definition of military communication equipment, testing the received data with custom developed algorithm based on Markov decision process for automating the medical emergency protocol (MDP-AMEP and implementation of adequate data protocols for data transmitting. Obtained results showed that physiological status of the military personnel can be successfully monitored by using tactical military network.

  17. Sequential monitoring with conditional randomization tests

    CERN Document Server

    Plamadeala, Victoria; 10.1214/11-AOS941

    2012-01-01

    Sequential monitoring in clinical trials is often employed to allow for early stopping and other interim decisions, while maintaining the type I error rate. However, sequential monitoring is typically described only in the context of a population model. We describe a computational method to implement sequential monitoring in a randomization-based context. In particular, we discuss a new technique for the computation of approximate conditional tests following restricted randomization procedures and then apply this technique to approximate the joint distribution of sequentially computed conditional randomization tests. We also describe the computation of a randomization-based analog of the information fraction. We apply these techniques to a restricted randomization procedure, Efron's [Biometrika 58 (1971) 403--417] biased coin design. These techniques require derivation of certain conditional probabilities and conditional covariances of the randomization procedure. We employ combinatoric techniques to derive t...

  18. KSC inventor tests cabin pressure monitor

    Science.gov (United States)

    2000-01-01

    Jan Zysko (left) and Rich Mizell (right) test a Personal Cabin Pressure Altitude Monitor in an altitude chamber at Tyndall Air Force Base in Florida. Zysko invented the pager-sized monitor that alerts wearers of a potentially dangerous or deteriorating cabin pressure altitude condition, which can lead to life- threatening hypoxia. Zysko is chief of the KSC Spaceport Engineering and Technology directorate's data and electronic systems branch. Mizell is a Shuttle processing engineer. The monitor, which has drawn the interest of such organizations as the Federal Aviation Administration for use in commercial airliners and private aircraft, was originally designed to offer Space Shuttle and Space Station crew members added independent notification about any depressurization.

  19. Monitor for displaying the status of Real-Time simulation.

    OpenAIRE

    2014-01-01

    This paper presents a design and implementation of a monitor to display the status of real-time simulation and modelling for discrete event dynamic systems, DEDS. The modelling and simulation of DEDS in this thesis are implemented using two kinds tools called Petri net and GpenSIM. Petri Nets are tools that are widely used now a day to model and simulate discrete events of concurrent and dynamic systems. [1] Petri net has a graphical formalism that is getting popularity in recent years as a t...

  20. Implementing and Innovating Marine Monitoring Approaches for Assessing Marine Environmental Status

    KAUST Repository

    Danovaro, Roberto

    2016-11-23

    Marine environmental monitoring has tended to focus on site-specific methods of investigation. These traditional methods have low spatial and temporal resolution and are relatively labor intensive per unit area/time that they cover. To implement the Marine Strategy Framework Directive (MSFD), European Member States are required to improve marine monitoring and design monitoring networks. This can be achieved by developing and testing innovative and cost-effective monitoring systems, as well as indicators of environmental status. Here, we present several recently developed methodologies and technologies to improve marine biodiversity indicators and monitoring methods. The innovative tools are discussed concerning the technologies presently utilized as well as the advantages and disadvantages of their use in routine monitoring. In particular, the present analysis focuses on: (i) molecular approaches, including microarray, Real Time quantitative PCR (qPCR), and metagenetic (metabarcoding) tools; (ii) optical (remote) sensing and acoustic methods; and (iii) in situ monitoring instruments. We also discuss their applications in marine monitoring within the MSFD through the analysis of case studies in order to evaluate their potential utilization in future routine marine monitoring. We show that these recently-developed technologies can present clear advantages in accuracy, efficiency and cost.

  1. Implementing and innovating marine monitoring approaches for assessing marine environmental status

    Directory of Open Access Journals (Sweden)

    Roberto Danovaro

    2016-11-01

    Full Text Available Marine environmental monitoring has tended to focus on site-specific methods of investigation. These traditional methods have low spatial and temporal resolution and are relatively labour intensive per unit area/time that they cover. To implement the Marine Strategy Framework Directive (MSFD, European Member States are required to improve marine monitoring and design monitoring networks. This can be achieved by developing and testing innovative and cost-effective monitoring systems, as well as indicators of environmental status. Here, we present several recently developed methodologies and technologies to improve marine biodiversity indicators and monitoring methods. The innovative tools are discussed concerning the technologies presently utilized as well as the advantages and disadvantages of their use in routine monitoring. In particular, the present analysis focuses on: (i molecular approaches, including microarray, Real Time quantitative PCR (qPCR, and metagenetic (metabarcoding tools; (ii optical (remote sensing and acoustic methods; and (iii in situ monitoring instruments. We also discuss their applications in marine monitoring within the MSFD through the analysis of case studies in order to evaluate their potential utilization in future routine marine monitoring. We show that these recently-developed technologies can present clear advantages in accuracy, efficiency and cost.

  2. Silicon Carbide Temperature Monitor Processing Improvements. Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Unruh, Troy Casey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Daw, Joshua Earl [Idaho National Lab. (INL), Idaho Falls, ID (United States); Al Rashdan, Ahamad [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-01-29

    Silicon carbide (SiC) temperature monitors are used as temperature sensors in Advanced Test Reactor (ATR) irradiations at the Idaho National Laboratory (INL). Although thermocouples are typically used to provide real-time temperature indication in instrumented lead tests, other indicators, such as melt wires, are also often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires as a post-irradiation technique for peak temperature indication. Melt wires are limited in that they can only detect whether a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that occurred during irradiation. As part of the process initiated to make SiC temperature monitors available at the ATR, post-irradiation evaluations of these monitors have been previously completed at the High Temperature Test Laboratory (HTTL). INL selected the resistance measurement approach for determining irradiation temperature from SiC temperature monitors because it is considered to be the most accurate measurement. The current process involves the repeated annealing of the SiC monitors at incrementally increasing temperature, with resistivity measurements made between annealing steps. The process is time consuming and requires the nearly constant attention of a trained staff member. In addition to the expensive and lengthy post analysis required, the current process adds many potential sources of error in the measurement, as the sensor must be repeatedly moved from furnace to test fixture. This time-consuming post irradiation analysis is a significant portion of the total cost of using these otherwise inexpensive sensors. An additional consideration of this research is that, if the SiC post processing can be automated, it

  3. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  4. Monitoring training status with HR measures: do all roads lead to Rome?

    Directory of Open Access Journals (Sweden)

    Martin eBuchheit

    2014-02-01

    Full Text Available Monitoring an athlete's physiological status in response to various types and volumes of (aerobic-oriented training can provide useful information for optimizing training programs. Measures of resting, exercise and recovery heart rate (HR are receiving increasing interest for monitoring fatigue, fitness and endurance performance responses, which has direct implications for adjusting training load 1 daily during specific training blocks and 2 throughout the competitive season. These measures are still not widely implemented to monitor athletes’ responses to training load, probably because of apparent contradictory findings in the literature. In this review I contend that most of the contradictory findings are related to methodological inconsistencies and/or misinterpretation of the data rather than to limitations of heart rate measures to accurately inform on training status. I also provide evidence that measures derived from 5-min (almost daily recordings of resting (indices capturing beat-to-beat changes in HR, reflecting parasympathetic activity and submaximal exercise (30- to 60-s average HR are likely the most useful monitoring tools. For appropriate interpretation at the individual level, changes in a given measure should be interpreted by taking into account the error of measurement and the smallest important change of the measure, as well as the training context (training phase, load and intensity distribution. The decision to use a given measure should be based upon the level of information that is required by the athlete, the marker’s sensitivity to changes in training status and the practical constrains required for the measurements. However, measures of HR cannot inform on all aspects of wellness, fatigue and performance, so their use in combination with daily training logs, psychometric questionnaires and non-invasive, cost-effective performance tests such as a countermovement jump may offer a complete solution to monitor

  5. Laser Wire and Beam Position Monitor tests

    CERN Document Server

    Boogert, S T; Lyapin, A; Nevay, L; Snuverink, J

    2013-01-01

    This subtask involved two main activities; Firstly the development and subsequent usage of high resolution beam position monitors (BPM) for the International Linear Collider (ILC) and Compact Linear Collider projects (CLIC); and secondly the development of a laser-wire (LW) transverse beam size measurement systems. This report describes the technical progress achieved at a large-scale test ILC compatible BPM system installed at the Accelerator Test Facility 2 (ATF2). The ATF2 is an energy-scaled demonstration system for the final focus systems required to deliver the particle beams to collision at the ILC and CLIC. The ATF2 cavity beam position monitor system is one of the largest of its kind and rivals systems used at free electron lasers. The ATF2 cavity beam position system has achieved a position resolutionof 250 nm (with signal attuenation) and 27 nm (without attenuation). The BPM system has been used routinely for lattice diagnostics, beam based alignment and wakefield measurements. Extensive experience...

  6. Biological Status Monitoring of European Fresh Water with Sentinel-2

    Science.gov (United States)

    Serra, Romain; Mangin, Antoine; Fanton d'Andon, Odile Hembise; Lauters, Francois; Thomasset, Franck; Martin-Lauzer, Francois-Regis

    2016-08-01

    Thanks to a widening range of sensors available, the observation of continental water quality for lakes and reservoirs is gaining more and more consistency and accuracy.Consistency because back in 2012, the only free sensor with a sufficient resolution (30m) was Landsat-7 which has truncated data since 2003 and a 16-day revisit time. But today, Landsat-8 and Sentinel-2A are now operating so depending on the latitude of interest, the combined revisit time dropped to 2 to 4 days which is more appropriate for such a monitoring (especially considering the cloud cover).Accuracy because Landsat-7 has a poor contrast over water whereas Landsat-8 and Sentinel-2A have a better radiometric sensitivity (more bit) and moreover Sentinel-2 offers additional spectral bands in the visible which are helpful for Chlorophyll-A concentration assessment. To sum up, with Sentinel-2, continental water quality monitoring capabilities are making a giant leap and it is important to exploit this potential the sooner. ACRI-HE has already built a strong basis to prepare Sentinel-2 by using Landsat data.Indeed, more than 600 lakes are already constantly monitored using Landsat data and their biological statuses are available on EyeOnWater (see eyeonwater.eu). Chlorophyll-A retrieval from (fresh) water leaving reflectances is the result of research activities conducted by ACRI-HE in parallel with EDF (Electricité de France) to respond to an emerging very demanding environmental monitoring through European regulations (typically the Water Framework Directive). Two parallel and complementary algorithms have thus been derived for Chlorophyll-a retrieval.Upstream of Eyeonwater, there is a complex and complete system automatically collecting images, extracting areas of interest around lakes, applying atmospheric correction (very sensitive part as atmosphere can contribute to 90% of the signal at sensor level) and then algorithms to retrieve water transparency (Secchi disk), turbidity and Chlorophyll

  7. Terahertz time domain spectroscopy allows contactless monitoring of grapevine water status

    Directory of Open Access Journals (Sweden)

    Luis Gonzaga Santesteban

    2015-06-01

    Full Text Available Agriculture is the sector with the greatest water consumption, since food production is frequently based on crop irrigation. Proper irrigation management requires reliable information on plant water status, but all the plant-based methods to determine it suffer from several inconveniences, mainly caused by the necessity of destructive sampling or of alteration of the plant organ due to contact installation. The aim of this work is to test if THz time domain reflectance measurements made on the grapevine trunk allows contactless monitoring of plant status. The experiments were performed on a potted 14-years old plant, using a general purpose THz emitter receiver head.Trunk THz time-domain reflection signal proved to be very sensitive to changes in plant water availability, as its pattern follows the trend of soil water content and trunk growth variations. Therefore, it could be used to contactless monitor plant water status. Apart from that, THz reflection signal was observed to respond to light conditions which, according to a specifically designed girdling experiment, was caused by changes in the phloem. This latter results opens a promising field of research for contactless monitoring of phloem activity.

  8. Status of the delta synchrotron light-monitoring-system

    CERN Document Server

    Berges, U

    2000-01-01

    A synchrotron radiation source like DELTA needs an optical monitoring system to measure the beam size at different points of the ring with high resolution and accuracy. The measurements with the present synchrotron light monitors show that beam sizes larger than 250 μm can be measured. The measured emittance is of the order of the theoretical values of the optics and goes down to 8 nm rad. The magnification of the system can simply be increased by adding another lens to measure smaller emittances and beamsizes down to 100 μm. In this case you still have an optical image of the beam available, but sometimes the position of the camera has to be adapted due to the great magnification of the optical system. The image processing system which is based on a VME Framegrabber makes a two dimensional gaussian fit to the images from different synchrotron light-monitors. First tests with monochromatic components of the synchrotron radiation (500 nm and 550 nm) and with short time cameras (shutter time...

  9. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    Energy Technology Data Exchange (ETDEWEB)

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it shows that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.

  10. Status of the Flooding Fragility Testing Development

    Energy Technology Data Exchange (ETDEWEB)

    Pope, C. L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Savage, B. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bhandari, B. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kamerman, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Muchmore, C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Roberts, G. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ryan, E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Suresh, S. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tahhan, A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wells, A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Smith, C. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-06-01

    This report provides an update on research addressing nuclear power plant component reliability under flooding conditions. The research includes use of the Component Flooding Evaluation Laboratory (CFEL) where individual components and component subassemblies will be tested to failure under various flooding conditions. The resulting component reliability data can then be incorporated with risk simulation strategies to provide a more thorough representation of overall plant risk. The CFEL development strategy consists of four interleaved phases. Phase 1 addresses design and application of CFEL with water rise and water spray capabilities allowing testing of passive and active components including fully electrified components. Phase 2 addresses research into wave generation techniques followed by the design and addition of the wave generation capability to CFEL. Phase 3 addresses methodology development activities including small scale component testing, development of full scale component testing protocol, and simulation techniques including Smoothed Particle Hydrodynamic (SPH) based computer codes. Phase 4 involves full scale component testing including work on full scale component testing in a surrogate CFEL testing apparatus.

  11. DNA Sequencing as a Tool to Monitor Marine Ecological Status

    Directory of Open Access Journals (Sweden)

    Kelly D. Goodwin

    2017-05-01

    Full Text Available Many ocean policies mandate integrated, ecosystem-based approaches to marine monitoring, driving a global need for efficient, low-cost bioindicators of marine ecological quality. Most traditional methods to assess biological quality rely on specialized expertise to provide visual identification of a limited set of specific taxonomic groups, a time-consuming process that can provide a narrow view of ecological status. In addition, microbial assemblages drive food webs but are not amenable to visual inspection and thus are largely excluded from detailed inventory. Molecular-based assessments of biodiversity and ecosystem function offer advantages over traditional methods and are increasingly being generated for a suite of taxa using a “microbes to mammals” or “barcodes to biomes” approach. Progress in these efforts coupled with continued improvements in high-throughput sequencing and bioinformatics pave the way for sequence data to be employed in formal integrated ecosystem evaluation, including food web assessments, as called for in the European Union Marine Strategy Framework Directive. DNA sequencing of bioindicators, both traditional (e.g., benthic macroinvertebrates, ichthyoplankton and emerging (e.g., microbial assemblages, fish via eDNA, promises to improve assessment of marine biological quality by increasing the breadth, depth, and throughput of information and by reducing costs and reliance on specialized taxonomic expertise.

  12. Real time monitoring of coating status for microsphere target with digital image difference method

    Institute of Scientific and Technical Information of China (English)

    Baixuan Shi(施柏煊); Xiao Huang(黄晓); Caifeng Li(李彩凤)

    2003-01-01

    Digital image difference method monitorring coating status of microsphere targets automatically is sug-gested. A CCD micro-imaging system is developed for monitoring the status of bouncing and adherencebetween microspheres and the bouncing pan. A new bouncing pan with multiple holes is adopted formicrosphere coating to enhance the microsphere coating efficiency.

  13. Monitoring of a Full-Scale Wing Fatigue Test

    NARCIS (Netherlands)

    Heida, Jaap; Hwang, Jason

    2014-01-01

    A wing of a decommissioned aircraft of the Royal Netherlands Air Force (RNLAF) was fatigue tested to more than two times the design life. Part of the test was the evaluation of load monitoring and Structural Health Monitoring (SHM) techniques. For load monitoring the data of conventional resistance

  14. Basic biochemical, hematological and hormonal parameters for monitoring the health and nutritional status in athletes

    Directory of Open Access Journals (Sweden)

    Aritz Urdampilleta

    2014-09-01

    Full Text Available Sporting competitions are becoming more demanding in terms of intensity of effort, and this means controlling all aspects that affect athletic performance. Food, hydration and supplementation, before, during and after training or competition directly affect health, body composition, performance and recovery of the athlete. The assessment of nutritional status is required for proper advising of the athlete, through blood tests to control the process of adaptation to training. The aim of this paper is to provide practical tools for dietitiansnutritionists to control the health and nutritional status of athletes, as well as monitoring their adaptation to workloads and competition periods. Performing analytical tests to control of protein metabolism, lipid profile, ions, blood tests and iron metabolism, in addition to review some hormonal parameters, may be of interest in order to observe the potential existence of overtraining states. The correct understanding and interpretation of laboratory tests (under sports doctor’s supervision will be most important and useful for dietitiansnutritionists, performing dietary and nutritional advice to athletes, because it will determine the status of the athlete and propose different individual feeding strategies depending on the training phase and response.

  15. Individual Monitoring and Occupational Dose Record Management in China: History, Current Status and Perspectives.

    Science.gov (United States)

    Wang, Hong-Bo; Yu, Hai-Tao; Sun, Quan-Fu

    2016-06-03

    This review paper presents an overview of individual monitoring, as well as the national dose register and dose record management of radiation workers in China. Progress has recently been made on the individual monitoring of radiation workers. A critical analysis of current status and problems in individual monitoring is also presented and necessary future research on individual monitoring, such as the monitoring technology in the form of the ring dosimeters and eye lens dosimeters, is suggested.

  16. Dual-wavelength photoacoustic technique for monitoring tissue status during thermal treatments

    Science.gov (United States)

    Hsiao, Yi-Sing; Wang, Xueding; Deng, Cheri X.

    2013-06-01

    Photoacoustic (PA) techniques have been exploited for monitoring thermal treatments. However, PA signals depend not only on tissue temperature but also on tissue optical properties which indicate tissue status (e.g., native or coagulated). The changes in temperature and tissue status often occur simultaneously during thermal treatments, so both effects cause changes to PA signals. A new dual-wavelength PA technique to monitor tissue status independent of temperature is performed. By dividing the PA signal intensities obtained at two wavelengths at the same temperature, a ratio, which only depends on tissue optical properties, is obtained. Experiments were performed with two experimental groups, one with untreated tissue samples and the other with high-intensity focused ultrasound treated tissue samples including thermal coagulated lesion, using ex vivo porcine myocardium specimens to test the technique. The ratio of PA signal intensities obtained at 700 and 800 nm was constant for both groups from 25 to 43°C, but with distinct values for the two groups. Tissue alteration during thermal treatment was then studied using water bath heating of tissue samples from 35 to 60°C. We found that the ratio stayed constant before it exhibited a marked increase at around 55°C, indicating tissue changes at this temperature.

  17. Monitoring Fatigue Status in Elite Team Sport Athletes: Implications for Practice.

    Science.gov (United States)

    Thorpe, Robin T; Atkinson, Greg; Drust, Barry; Gregson, Warren

    2017-01-17

    The increase in competition demands in elite team sports over recent years has prompted much attention from researchers and practitioners into the monitoring of adaptation and fatigue in athletes. Monitoring of fatigue and gaining an understanding of athlete status may also provide insights and beneficial information pertaining to player availability, injury and illness risk. Traditional methods used to quantify recovery and fatigue in team sports such as maximal physical performance assessments may not be feasible in order to detect variations in fatigue status throughout competitive periods. The implementation of more quick, simple and non-exhaustive tests such as athlete self-report measures (ASRM), autonomic nervous system (ANS) response via heart rate derived indices and to a lesser extent jump protocols may serve as promising tools to quantify and establish fatigue status in elite team sport athletes. The robust rationalization and precise detection of a meaningful fluctuation in these measures are of paramount importance for practitioners working alongside athletes and coaches on a daily basis. There are various methods for arriving at a minimal clinically important difference (MCID), but these have been rarely adopted by sports scientists and practitioners. The implementation of appropriate, reliable and sensitive measures of fatigue can provide important information to key stakeholders within team sport environments. Future research is required to investigate the sensitivity of these tools to fundamental indicators such as performance, injury and illness.

  18. LWRS ATR Irradiation Testing Readiness Status

    Energy Technology Data Exchange (ETDEWEB)

    Kristine Barrett

    2012-09-01

    The Light Water Reactor Sustainability (LWRS) Program was established by the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the life of the current reactors. The LWRS Program is divided into four R&D Pathways: (1) Materials Aging and Degradation; (2) Advanced Light Water Reactor Nuclear Fuels; (3) Advanced Instrumentation, Information and Control Systems; and (4) Risk-Informed Safety Margin Characterization. This report describes an irradiation testing readiness analysis in preparation of LWRS experiments for irradiation testing at the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) under Pathway (2). The focus of the Advanced LWR Nuclear Fuels Pathway is to improve the scientific knowledge basis for understanding and predicting fundamental performance of advanced nuclear fuel and cladding in nuclear power plants during both nominal and off-nominal conditions. This information will be applied in the design and development of high-performance, high burn-up fuels with improved safety, cladding integrity, and improved nuclear fuel cycle economics

  19. 9 CFR 147.14 - Procedures to determine status and effectiveness of sanitation monitored program.

    Science.gov (United States)

    2010-01-01

    ... effectiveness of sanitation monitored program. 147.14 Section 147.14 Animals and Animal Products ANIMAL AND... status and effectiveness of sanitation monitored program. The following monitoring procedures 10 may be... sanitation program. (1) Culture the surface of cased eggs periodically for fecal contaminating organisms...

  20. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    DeAnn Long; Michael Murphy

    2008-07-01

    Prior to April 2007, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site (NTS) was performed by the Radiological Health Instrumentation department. Calibration and performance testing on the PM-700 personnel portal monitor was performed, but there was no test program for the VM-250 vehicle portal monitor. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no performance test program. In April of 2007, the Material Control and Accountability Manager volunteered to take over performance testing of all SNM portal monitors at NTS in order to strengthen the program and meet U.S. Department of Energy Order requirements. This paper will discuss the following activities associated with developing a performance testing program: changing the culture, learning the systems, developing and implementing procedures, troubleshooting and repair, validating the process, physical control of equipment, acquisition of new systems, and implementing the performance test program.

  1. 40 CFR 146.68 - Testing and monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... to provide other site specific data; (iii) Periodic monitoring of the ground water quality in the first aquifer overlying the injection zone; (iv) Periodic monitoring of the ground water quality in the... Applicable to Class I Hazardous Waste Injection Wells § 146.68 Testing and monitoring requirements....

  2. Status of Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Chance, K.; Liu, X.; Suleiman, R. M.; Flittner, D. E.; Al-Saadi, J. A.; Janz, S. J.

    2016-12-01

    TEMPO is now in the Assembly, Integration and Test (AI&T) phase, having passed its Key Decision Point C, Critical Design Reviews (CDRs) for the instrument and the ground systems, and the Test Readiness Review (TRR). The TEMPO instrument is scheduled for delivery in August 2017. The request for proposals to host TEMPO on a commercial geostationary satellite is scheduled for release by May 2017, with host selection hopefully completed by the end of calendar 2017. TEMPO is thus on schedule to measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City and Cuba to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution. It provides a measurement suite that includes the key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the high variability in the diurnal cycle of emissions and chemistry. The small spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies.TEMPO takes advantage of a GEO host spacecraft to provide a mission that measures the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available.TEMPO provides much of the atmospheric measurement capability recommended for GEO-CAPE in the 2007 National Research Council Decadal Survey, Earth Science and Applications from Space

  3. Seismic monitoring at Cascade Volcanic Centers, 2004?status and recommendations

    Science.gov (United States)

    Moran, Seth C.

    2004-01-01

    The purpose of this report is to assess the current (May, 2004) status of seismic monitoring networks at the 13 major Cascade volcanic centers. Included in this assessment are descriptions of each network, analyses of the ability of each network to detect and to locate seismic activity, identification of specific weaknesses in each network, and a prioritized list of those networks that are most in need of additional seismic stations. At the outset it should be recognized that no Cascade volcanic center currently has an adequate seismic network relative to modern-day networks at Usu Volcano (Japan) or Etna and Stromboli volcanoes (Italy). For a system the size of Three Sisters, for example, a modern-day, cutting-edge seismic network would ideally consist of a minimum of 10 to 12 short-period three-component seismometers (for determining particle motions, reliable S-wave picks, moment tensor inversions, fault-plane solutions, and other important seismic parameters) and 7 to 10 broadband sensors (which, amongst other considerations, enable detection and location of very long period (VLP) and other low-frequency events, moment tensor inversions, and, because of their wide dynamic range, on-scale recording of large-amplitude events). Such a dense, multi component seismic network would give the ability to, for example, detect in near-real-time earthquake migrations over a distance of ~0.5km or less, locate tremor sources, determine the nature of a seismic source (that is, pure shear, implosive, explosive), provide on-scale recordings of very small and very large-amplitude seismic signals, and detect localized changes in seismic stress tensor orientations caused by movement of magma bodies. However, given that programmatic resources are currently limited, installation of such networks at this time is unrealistic. Instead, this report focuses on identifying what additional stations are needed to guarantee that anomalous seismicity associated with volcanic unrest will be

  4. Space Station thermal test bed status and plans

    Science.gov (United States)

    Brady, Timothy K.

    1988-01-01

    The accomplishments, current status, and future plans of the thermal test bed program for Space Station thermal management are discussed. This program is intended to support the design and development of the thermal control systems for the Space Station. The topics discussed include heat pipe radiator evaluation, modular panel tests, two-phase heat transport, and testing of thermal buses using ammonia as the working fluid.

  5. Special Tests for Monitoring Fetal Health

    Science.gov (United States)

    ... growth problems, Rh sensitization , or high blood pressure • Decreased movement of the fetus • Pregnancy that goes past ... on how far along you are in your pregnancy, you may have another BPP within the next ... BPP performed? The fetal heart rate is monitored in the same way it is ...

  6. Intelligent Monitoring of Rocket Test Systems

    Science.gov (United States)

    Duran, Esteban; Rocha, Stephanie; Figueroa, Fernando

    2016-01-01

    Stephanie Rocha is an undergraduate student pursuing a degree in Mechanical Engineering. Esteban Duran is pursuing a degree in Computer Science. Our mentor is Fernando Figueroa. Our project involved developing Intelligent Health Monitoring at the High Pressure Gas Facility (HPGF) utilizing the software GensymG2.

  7. Stormwater and Wastewater Infrastructure Monitoring Test Bed

    Science.gov (United States)

    The growing application of stormwater and wastewater management in urban and urbanizing environments is increasing the demand for monitoring technologies and systems that can provide reliable performance data, in real-time or near real-time, for operation and maintenance decision...

  8. Job monitoring on the WLCG scope: Current status and new strategy

    CERN Document Server

    Andreeva, J; Belov, S; Casey, J; Dvorak, F; Gaidioz, B; Karavakis, E; Kodolova, O; Kokoszkiewicz, L; Krenek, A; Lanciotti, E; Maier, J; Mulac, M; Rocha Da Cunha Rodrigues, D F; Rocha, R; Saiz, P; Sidorova, I; Sitera, J; Tikhonenko, E; Vaibhav, K; Vocu, M

    2010-01-01

    Job processing and data transfer are the main computing activities on the WLCG infrastructure. Reliable monitoring of the job processing on the WLCG scope is a complicated task due to the complexity of the infrastructure itself and the diversity of the currently used job submission methods. The paper will describe current status and the new strategy for the job monitoring on the WLCG scope, covering primary information sources, job status changes publishing, transport mechanism and visualization.

  9. High Temperature Gas-Cooled Test Reactor Options Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    Preliminary scoping calculations are being performed for a 100 MWt gas-cooled test reactor. The initial design uses standard prismatic blocks and 15.5% enriched UCO fuel. Reactor physics and thermal-hydraulics simulations have been performed to identify some reactor design features to investigate further. Current status of the effort is described.

  10. Interim-status groundwater monitoring plan for the 216-B-63 trench

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, M.D.

    1995-02-09

    This document outlines the groundwater monitoring plan, under RCRA regulations in 40 CFR 265 Subpart F and WAC173-300-400, for the 216-B-63 Trench. This interim status facility is being sampled under detection monitoring criteria and this plan provides current program conditions and requirements.

  11. FBG-Based Monitoring of Geohazards: Current Status and Trends.

    Science.gov (United States)

    Zhu, Hong-Hu; Shi, Bin; Zhang, Cheng-Cheng

    2017-02-24

    In recent years, natural and anthropogenic geohazards have occured frequently all over the world, and field monitoring is becoming an increasingly important task to mitigate these risks. However, conventional geotechnical instrumentations for monitoring geohazards have a number of weaknesses, such as low accuracy, poor durability, and high sensitivity to environmental interferences. In this aspect, fiber Bragg grating (FBG), as a popular fiber optic sensing technology, has gained an explosive amount of attention. Based on this technology, quasi-distributed sensing systems have been established to perform real-time monitoring and early warning of landslides, debris flows, land subsidence, earth fissures and so on. In this paper, the recent research and development activities of applying FBG systems to monitor different types of geohazards, especially those triggered by human activities, are critically reviewed. The working principles of newly developed FBG sensors are briefly introduced, and their features are summarized. This is followed by a discussion of recent case studies and lessons learned, and some critical problems associated with field implementation of FBG-based monitoring systems. Finally the challenges and future trends in this research area are presented.

  12. Status and perspectives of the “Specially Monitored Track”

    Science.gov (United States)

    Asmussen, B.; Onnich, H.; Strube, R.; Greven, L. M.; Schröder, S.; Jäger, K.; Degen, K. G.

    2006-06-01

    Deutsche Bahn AG has developed and continuously improved over the last decade a system called "Specially Monitored Track". It is based on the fact that the noise emission from railways can be reduced by rail grinding and has been confirmed officially in 1998 by the German Federal Railway Office (EBA) as a noise reduction system with an effectiveness of -3 dB(A). Meanwhile almost 1000 km of DB's network are specially monitored. In order to comply with this legislation, intensive grinding and monitoring is required. The latter is done by a dedicated monitoring car and supplemented by roughness measurements using a modified roughness-measuring device in connection with a newly developed algorithm for data analysis, enabling a prediction of the noise emission on the basis of roughness measurements. Future developments will aim at increasing the performance of the system "Specially Monitored Track". This will particularly include grinding at high working speeds ("High Speed Grinding") with two targets: (1) reducing costs for rail grinding and (2) merging rail grinding for acoustic reasons with grinding for regular track maintenance.

  13. FBG-Based Monitoring of Geohazards: Current Status and Trends

    Directory of Open Access Journals (Sweden)

    Hong-Hu Zhu

    2017-02-01

    Full Text Available In recent years, natural and anthropogenic geohazards have occured frequently all over the world, and field monitoring is becoming an increasingly important task to mitigate these risks. However, conventional geotechnical instrumentations for monitoring geohazards have a number of weaknesses, such as low accuracy, poor durability, and high sensitivity to environmental interferences. In this aspect, fiber Bragg grating (FBG, as a popular fiber optic sensing technology, has gained an explosive amount of attention. Based on this technology, quasi-distributed sensing systems have been established to perform real-time monitoring and early warning of landslides, debris flows, land subsidence, earth fissures and so on. In this paper, the recent research and development activities of applying FBG systems to monitor different types of geohazards, especially those triggered by human activities, are critically reviewed. The working principles of newly developed FBG sensors are briefly introduced, and their features are summarized. This is followed by a discussion of recent case studies and lessons learned, and some critical problems associated with field implementation of FBG-based monitoring systems. Finally the challenges and future trends in this research area are presented.

  14. Monitoring and assessment of conservation status of the Eurasian Otter (Lutra lutra) in Denmark

    DEFF Research Database (Denmark)

    Søgaard, Bjarne; Madsen, Aksel Bo; Elmeros, Morten

    Monitoring and assessment of conservation status of the Eurasian Otter Lutra lutra in Denmark Søgaard B. ¹, Madsen A.B.¹, Elmeros M.¹ ¹Institute of Bioscience - Kaloe, Aarhus University. Keywords: Eurasian Otter; Monitoring; Conservation status According to the EU Habitats Directive Denmark has...... initiated systematic monitoring of species in the Annex II and IV of the Directive – including the Eurasian Otter (Lutra lutra). The program focuses on monitoring distribution and range of the otter population in order to provide an assessment of its conservation status. The otter Lutra lutra suffered...... serious declines in Denmark during the 1960s and 1970s. A series of conservation and management projects were initiated to protect the remnant population, including national surveys and the development of a management plan for the otter in Denmark in 1996. The recovery of the otter in Denmark...

  15. The effects of test interpretation styles and the status of tests in career counseling

    Directory of Open Access Journals (Sweden)

    Nelia Frade

    2007-03-01

    Full Text Available The effects of two styles of test interpretation, namely directive and collaborative, and clients’ perceptions of the technical status of tests, namely high and low, were compared for 32 postgraduate psychology students who served as career counseling clients. Clients who received a collaborative interpretation perceived their counselor as more attractive and trustworthy than did clients who received a directive test interpretation. Interpretation style did not have an effect on session impact. Clients’ perceptions of test status had a noticeable, but statistically non-significant effect on counselor evaluations and session impact. Implications for test-interpretation practice are discussed.

  16. Cow status monitoring (health and oestrus) using detection sensors

    NARCIS (Netherlands)

    Maatje, K.; Mol, de R.M.; Rossing, W.

    1997-01-01

    In-line sensors were used to measure quarter milk conductivity and milk temperature in the milking claw for monitoring mastitis in dairy cows. In a preliminary experiment, sensor data were used to develop algorithms and threshold values for the detection of mastitis. In a later experiment, these thr

  17. Cow status monitoring (health and oestrus) using detection sensors

    NARCIS (Netherlands)

    Maatje, K.; Mol, de R.M.; Rossing, W.

    1997-01-01

    In-line sensors were used to measure quarter milk conductivity and milk temperature in the milking claw for monitoring mastitis in dairy cows. In a preliminary experiment, sensor data were used to develop algorithms and threshold values for the detection of mastitis. In a later experiment, these

  18. The development of android - based children's nutritional status monitoring system

    Science.gov (United States)

    Suryanto, Agus; Paramita, Octavianti; Pribadi, Feddy Setio

    2017-03-01

    The calculation of BMI (Body Mass Index) is one of the methods to calculate the nutritional status of a person. The BMI calculation has not yet widely understood and known by the public. In addition, people should know the importance of progress in the development of child nutrition each month. Therefore, an application to determine the nutritional status of children based on Android was developed in this study. This study restricted the calculation for children with the age of 0-60 months. The application can run on a smartphone or tablet PC with android operating system due to the rapid development of a smartphone or tablet PC with android operating system and many people own and use it. The aim of this study was to produce a android app to calculate of nutritional status of children. This study was Research and Development (R & D), with a design approach using experimental studies. The steps in this study included analyzing the formula of the Body Mass Index (BMI) and developing the initial application with the help of a computer that includes the design and manufacture of display using Eclipse software. This study resulted in android application that can be used to calculate the nutritional status of children with the age 0-60 months. The results of MES or the error calculation analysis using body mass index formula was 0. In addition, the results of MAPE percentage was 0%. It shows that there is no error in the calculation of the application based on the BMI formula. The smaller value of MSE and MAPE leads to higher level of accuracy.

  19. Mechanisms Engineering Test Loop - Phase 1 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Kultgen, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Hvasta, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Lisowski, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Toter, W. [Argonne National Lab. (ANL), Argonne, IL (United States); Borowski, A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    This report documents the current status of the Mechanisms Engineering Test Loop (METL) as of the end of FY2016. Currently, METL is in Phase I of its design and construction. Once operational, the METL facility will test small to intermediate-scale components and systems in order to develop advanced liquid metal technologies. Testing different components in METL is essential for the future of advanced fast reactors as it will provide invaluable performance data and reduce the risk of failures during plant operation.

  20. Monitoring fluid status at the outpatient level: the need for more precision.

    LENUS (Irish Health Repository)

    McDonald, Ken

    2012-02-01

    Accurate determination of fluid status in patients with heart failure is a critical aspect of care of this population. Early detection of emerging fluid overload would allow for prompt intervention, potentially aborting clinical deterioration and avoiding hospitalization. While many strategies are available to determine fluid status of patients, all areas are compromised by less-than-optimal sensitivity and specificity. Recent work on the role of bioimpedance as a means of assessing a patient\\'s fluid status indicates that this parameter may have a role in monitoring patients with heart failure. This article reviews present techniques available for assessment of fluid status and focuses on the additional information provided by bioimpedance assessment.

  1. Monitoring fluid status at the outpatient level: the need for more precision.

    LENUS (Irish Health Repository)

    McDonald, Ken

    2010-07-01

    Accurate determination of fluid status in patients with heart failure is a critical aspect of care of this population. Early detection of emerging fluid overload would allow for prompt intervention, potentially aborting clinical deterioration and avoiding hospitalization. While many strategies are available to determine fluid status of patients, all areas are compromised by less-than-optimal sensitivity and specificity. Recent work on the role of bioimpedance as a means of assessing a patient\\'s fluid status indicates that this parameter may have a role in monitoring patients with heart failure. This article reviews present techniques available for assessment of fluid status and focuses on the additional information provided by bioimpedance assessment.

  2. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  3. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging the Phase I achievements of the Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) including its software toolsets and system building...

  4. Distributed Rocket Engine Testing Health Monitoring System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The on-ground and Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) provides a system architecture and software tools for performing diagnostics...

  5. Beta Testing of Persistent Passive Acoustic Monitors

    Science.gov (United States)

    2012-10-01

    solution. This translates into longer deployments on platforms such as gliders with limited hotel load. 2. the DMON is specifically designed for low...filter or filter bank may improve performance • Glider and Profiler motors and pumps are noisy , however duty cycle of noise is low. Therefore they are...power making it ideal for low hotel load autonomous vehicles like gliders. The format shown here was provided to beta-test clients working on gliders and

  6. Medication monitoring and drug testing ethics project.

    Science.gov (United States)

    Payne, Richard; Moe, Jeffrey L; Sevier, Catherine Harvey; Sevier, David; Waitzkin, Michael

    2015-01-01

    In 2012, Duke University initiated a research project, funded by an unrestricted research grant from Millennium Laboratories, a drug testing company. The project focused on assessing the frequency and nature of questionable, unethical, and illegal business practices in the clinical drug testing industry and assessing the potential for establishing a business code of ethics. Laboratory leaders, clinicians, industry attorneys, ethicists, and consultants participated in the survey, were interviewed, and attended two face-to-face meetings to discuss a way forward. The study demonstrated broad acknowledgment of variations in the legal and regulatory environment, resulting in inconsistent enforcement of industry practices. Study participants expressed agreement that overtly illegal practices sometimes exist, particularly when laboratory representatives and clinicians discuss reimbursement, extent of testing, and potential business incentives with medical practitioners. Most respondents reported directly observing probable violations involving marketing materials, contracts, or, in the case of some individuals, directly soliciting people with offers of clinical supplies and other "freebies." While many study respondents were skeptical that voluntary standards alone would eliminate questionable business practices, most viewed ethics codes and credentialing as an important first step that could potentially mitigate uneven enforcement, while improving quality of care and facilitating preferred payment options for credentialed parties. Many were willing to participate in future discussions and industry-wide initiatives to improve the environment.

  7. US national breastfeeding monitoring and surveillance: current status and recommendations.

    Science.gov (United States)

    Chapman, Donna J; Pérez-Escamilla, Rafael

    2009-05-01

    Eleven federally funded datasets assessing breastfeeding behaviors in the United States (Early Childhood Longitudinal Survey, Infant Feeding Practices Survey II, National Health and Nutrition Examination Survey, National Immunization Survey, National Survey of Children's Health, National Survey of Early Childhood Health, National Survey of Family Growth, Pediatric Nutrition Surveillance System, Pregnancy Nutrition Surveillance System, Pregnancy Risk Assessment Monitoring Survey, and WIC Participant and Program Characteristics) were reviewed to evaluate breastfeeding variables (initiation, duration and exclusivity) and determine whether relevant breastfeeding determinants were collected to evaluate breastfeeding practices from a health disparities perspective. The datasets used inconsistent breastfeeding definitions, limited ethnic descriptors, and varied regarding availability of relevant determinants. Multiple datasets collect breastfeeding data, but a coordinated US breastfeeding monitoring and surveillance system does not exist. Suggestions to improve this system include: standardizing breastfeeding definitions, expanding ethnic/racial descriptors, collecting additional relevant variables, and reducing recall periods.

  8. Lumped Parameter Modeling as a Predictive Tool for a Battery Status Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; Chester G. Motloch; Chinh D. Ho; John L. Morrison; Ronald C. Fenton; Vincent S. Battaglia; Tien Q. Duong

    2003-10-01

    The Advanced Technology Development Program is currently evaluating the performance of the second generation of lithium-ion cells (i.e., Gen 2 cells). Both the Gen 2 Baseline and Variant C cells are tested in accordance with the cell-specific test plan, and are removed at roughly equal power fade increments and sent for destructive diagnostic analysis. The diagnostic laboratories did not need all test cells for analysis, and returned five spare cells to the Idaho National Engineering and Environmental Laboratory (INEEL). INEEL used these cells for special pulse testing at various duty cycles, amplitudes, and durations to investigate the usefulness of the lumped parameter model (LPM) as a predictive tool in a battery status monitor (BSM). The LPM is a simplified linear model that accurately predicts the voltage response during certain pulse conditions. A database of parameter trends should enable dynamic predictions of state-of-charge and state-of-health conditions during in-vehicle pulsing. This information could be used by the BSM to provide accurate information to the vehicle control system.

  9. Status of the flora and fauna on the Nevada Test Site, 1989--1991

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1994-03-01

    This volume includes six reports of monitoring work to determine the status of and trends in flora and fauna populations on the Nevada Test Site (NTS) from 1989 through 1991. The Nevada Operations Office of the US Department of Energy supported monitoring under its Basic Environmental Compliance and Monitoring Program (BECAMP) since 1987. Under this program several undisturbed baseline plots, and numerous plots in disturbed areas, are sampled on annual or three-year cycles. Perennial plant populations, ephemeral plants, small mammals, reptiles, birds, and large mammals were monitored. Monitoring results are reported for five baseline sites, one from each major landform on the NTS (Jackass Flats, Frenchman Flat, Yucca Flat, Pahute Mesa, and Rainier Mesa), and for areas cleared of vegetation by fires, atmospheric nuclear weapons tests, construction, and gophers. Roadside flora and fauna were studied at two locations, and several historical study plots around the NTS were recensused to determine vegetation changes over long time spans. Three subsidence craters resulting from below-ground nuclear weapons tests were also studied. A major influence on plants and animals during the report period was a severe drought during 1989 and 1990, followed by more moderate drought in 1991.

  10. Status and applications of echinoid (phylum echinodermata) toxicity test methods

    Energy Technology Data Exchange (ETDEWEB)

    Bay, S.; Burgess, R.; Nacci, D.

    1993-01-01

    The use of echinoderms for toxicity testing has focused primarily on sea urchins and sand dollars (Strongylocentrotus purpuratus, Arbacia punctulata, Lytechinus pictus, and Dendraster excentricus, for example). The status and relative sensitivity of various test methods are described. The most frequently used test methods consist of short-term exposures of sea urchin sperm or embryos; these tests can be easily conducted at all times of the year by using species with complementary spawning cycles or laboratory conditioned populations of a single species. Data from reference toxicant and effluent toxicity tests are summarized. Information on the precision and sensitivity of echinoid test methods are limited and preclude rigorous comparisons with other test methods. The available data indicate that the sensitivity and precision of these methods are comparable to short-term chronic methods for other marine invertebrates and fish. Recent application of the sperm test in toxicity identification evaluations (TIEs) and studies of effluent toxicity decay and sediment toxicity illustrate the versatility of this rapid (10 to 60 min exposure) test method. Embryo tests typically use a 48 to 96 h exposure period and measure the occurrence of embryo malformations. Most recent applications of the embryo test have been for the assessment of sediment elutriate toxicity. Adult echinoderms are not frequently used to assess effluent or receiving water toxicity. Recent studies have had success in using the adult life stage of urchins and sand dollars to assess the effects of contaminated sediment on growth, behavior, and bioaccumulation.

  11. ISTAR: Project Status and Ground Test Engine Design

    Science.gov (United States)

    Quinn, Jason Eugene

    2003-01-01

    Review of the current technical and programmatic status of the Integrated System Test of an Airbreathing Rocket (ISTAR) project. November 2002 completed Phase 1 of this project: which worked the conceptual design of the X-43B demonstrator vehicle and Flight Test Engine (FTE) order to develop realistic requirements for the Ground Test Engine (GTE). The latest conceptual FTE and X-43B configuration is briefly reviewed. The project plan is to reduce risk to the GTE and FTE concepts through several tests: thruster, fuel endothermic characterization, engine structure/heat exchanger, injection characterization rig, and full scale direct connect combustion rig. Each of these will be discussed along with the project schedule. This discussion is limited due to ITAR restrictions on open literature papers.

  12. Therapeutic drug monitoring for imatinib: Current status and Indian experience.

    Science.gov (United States)

    Arora, Brijesh; Gota, Vikram; Menon, Hari; Sengar, Manju; Nair, Reena; Patial, Pankaj; Banavali, S D

    2013-07-01

    Imatinib is the current gold standard for treatment of chronic myeloid leukemia (CML). Recent pharmacokinetic studies have shown considerable variability in trough concentrations of imatinib due to variations in its metabolism, poor compliance, or drug-drug interactions and highlighted its impact on clinical response. A trough level close to 1000 ng/mL, appears to be correlated with better cytogenetic and molecular responses. Therapeutic Drug Monitoring (TDM) for imatinib may provide useful added information on efficacy, safety and compliance than clinical assessment alone and help in clinical decision making. It may be particularly helpful in patients with suboptimal response to treatment or treatment failure, severe or rare adverse events, possible drug interactions, or suspected nonadherence. Further prospective studies are needed to confirm relationship between imatinib plasma concentrations with response, and to define effective plasma concentrations in different patient populations.

  13. Isothermal test as a WLR monitor for Cu interconnects

    Science.gov (United States)

    Marathe, Amit P.; Pham, Van; Chan, Jay; Weidner, Jorg-Oliver; Heinig, Volker; Thierbach, Steffi

    2000-08-01

    The need for higher interconnect current densities has been increasing rapidly for advanced integrated circuits. Cu interconnects have emerged as viable candidates to replace Aluminium due to the lower sheet resistivity and increased electro migration lifetime of Cu. Previously, we had reported the use of the isothermal test as a WLR monitor for detecting process defects such as voids in the Aluminium interconnects. This paper further extends the application of the isothermal test methodology for detecting and characterizing process defects in Cu interconnect technology. Package electro migration test are time consuming and may be impractical in detecting process defects in a timely manner. Isothermal test, on the other hand, can be effectively used as a fast WLR process monitor. This paper reports the influence of direction of test current as well as different types of test structures, such as a single level NIST structure and a via chain structure and a via chain structure, on the isothermal test results for Cu interconnects. The isothermal test data has been shown to be helpful in evaluating the location and severity of the process defects through a proper choice of test structures. Joule heating due to high current density is found to be the major driving force for the sensitivity of isothermal test failures. A good correlation is also seen with the package electro migration data. A simple wafer level isothermal test has thus been successfully demonstrated as a reliability tool for process monitoring in Cu VLSI interconnects.

  14. METHOD OF ESTIMATION FREQUENCY PROPERTIES OF THE PREINSULATED PIPES FOR MONITORING THE STATUS OF HEATING NETWORKS

    Directory of Open Access Journals (Sweden)

    E. N. Taletskiy

    2014-01-01

    Full Text Available Proposed approximate method for the preliminary assessment of the frequency properties unadapted guiding system for monitoring the status of the organization of preinsulated pipes. Guide system elements  formed  tubes  placed  in  a  lossy  medium  (soil.  A  theoretical  analysis  shows  the  frequency dependence of the propagation constant components: the damping coefficient and the phase coefficient, take advantage of these characteristics of the system for monitoring the status heating networks.

  15. Current Status of Neuromuscular Reversal and Monitoring: Challenges and Opportunities.

    Science.gov (United States)

    Brull, Sorin J; Kopman, Aaron F

    2017-01-01

    Postoperative residual neuromuscular block has been recognized as a potential problem for decades, and it remains so today. Traditional pharmacologic antagonists (anticholinesterases) are ineffective in reversing profound and deep levels of neuromuscular block; at the opposite end of the recovery curve close to full recovery, anticholinesterases may induce paradoxical muscle weakness. The new selective relaxant-binding agent sugammadex can reverse any depth of block from aminosteroid (but not benzylisoquinolinium) relaxants; however, the effective dose to be administered should be chosen based on objective monitoring of the depth of neuromuscular block.To guide appropriate perioperative management, neuromuscular function assessment with a peripheral nerve stimulator is mandatory. Although in many settings, subjective (visual and tactile) evaluation of muscle responses is used, such evaluation has had limited success in preventing the occurrence of residual paralysis. Clinical evaluations of return of muscle strength (head lift and grip strength) or respiratory parameters (tidal volume and vital capacity) are equally insensitive at detecting neuromuscular weakness. Objective measurement (a train-of-four ratio greater than 0.90) is the only method to determine appropriate timing of tracheal extubation and ensure normal muscle function and patient safety.

  16. Monitoring of metabolic profiling and water status of Hayward kiwifruits by nuclear magnetic resonance.

    Science.gov (United States)

    Capitani, D; Mannina, L; Proietti, N; Sobolev, A P; Tomassini, A; Miccheli, A; Di Cocco, M E; Capuani, G; De Salvador, R; Delfini, M

    2010-10-15

    The metabolic profiling of kiwifruit (Actinidia deliciosa, Hayward cultivar) aqueous extracts and the water status of entire kiwifruits were monitored over the season (June-December) using nuclear magnetic resonance (NMR) methodologies. The metabolic profiling of aqueous kiwifruit extracts was investigated by means of high field NMR spectroscopy. A large number of water-soluble metabolites were assigned by means of 1D and 2D NMR experiments. The change in the metabolic profiles monitored over the season allowed the kiwifruit development to be investigated. Specific temporal trends of aminoacids, sugars, organic acids and other metabolites were observed. The water status of kiwifruits was monitored directly on the intact fruit measuring the T(2) spin-spin relaxation time by means of a portable unilateral NMR instrument, fully non-invasive. Again, clear trends of the relaxation time were observed during the monitoring period. The results show that the monitoring of the metabolic profiling and the monitoring of the water status are two complementary means suitable to have a complete view of the investigated fruit.

  17. Integrated Status and Effectiveness Monitoring Program, Entiat River Status and Trend Snorkel Surveys and Rotary Smolt Trap Operations in Nason Creek, March 2007 through March 2008.

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Matthew; Jorgensen, John; Murdock, Keely

    2008-03-10

    The Integrated Status and Effectiveness Monitoring Program (ISEMP-BPA project No.2003-0017) has been created as a cost effective means of developing protocols and new technologies, novel indicators, sample designs, analytical, data management and communication tools and skills, and restoration experiments that support the development of a region-wide Research, Monitoring and Evaluation (RME) program to assess the status of anadromous salmonid populations, their tributary habitat and restoration and management actions. The most straightforward approach to developing a regional-scale monitoring and evaluation program would be to increase standardization among status and trend monitoring programs. However, the diversity of species and their habitat, as well as the overwhelming uncertainty surrounding indicators, metrics, and data interpretation methods, requires the testing of multiple approaches. Thus, the approach ISEMP has adopted is to develop a broad template that may differ in the details among subbasins, but one that will ultimately lead to the formation of a unified RME process for the management of anadromous salmonid populations and habitat across the Columbia River Basin. ISEMP has been initiated in three pilot subbasins, the Wenatchee/Entiat, John Day, and Salmon. To balance replicating experimental approaches with the goal of developing monitoring and evaluation tools that apply as broadly as possible across the Pacific Northwest, these subbasins were chosen as representative of a wide range of potential challenges and conditions, e.g., differing fish species composition and life histories, ecoregions, institutional settings, and existing data. ISEMP has constructed a framework that builds on current status and trend monitoring infrastructures in these pilot subbasins, but challenges current programs by testing alternative monitoring approaches. In addition, the ISEMP is: (1) Collecting information over a hierarchy of spatial scales, allowing for a

  18. NUTRITIONAL STATUS AND BODY COMPOSITION IN PERITONEAL DIALYSIS PATIENTS: RELEVANCE OF BIOIMPEDANCEMETRY (BCM® FOR LONGITUDINAL MONITORING

    Directory of Open Access Journals (Sweden)

    Céline Nodimar

    2012-06-01

    We confirm that PD is associated with changes in BC, whether for incident or prevalent patients. The BCM®, a simple, reproducible and inexpensive technique, could be proposed in the systematic nutritional monitoring of PD patients, in order to detect early modification of nutritional status in those patients and then to adapt clinical management.

  19. Perceived Socio-Economic Status and Social Inclusion in School: Parental Monitoring and Support as Mediators

    Science.gov (United States)

    Veland, Jarmund; Bru, Edvin; Idsøe, Thormod

    2015-01-01

    The roles of parental monitoring and support (parenting styles) as mediators of the relationship between socio-economic status (SES) and perceived inclusion in school were studied in a sample of 7137 Norwegian primary and secondary school pupils aged between 10 and 16 years. To study whether additional social disadvantages moderated the…

  20. Perceived Socio-Economic Status and Social Inclusion in School: Parental Monitoring and Support as Mediators

    Science.gov (United States)

    Veland, Jarmund; Bru, Edvin; Idsøe, Thormod

    2015-01-01

    The roles of parental monitoring and support (parenting styles) as mediators of the relationship between socio-economic status (SES) and perceived inclusion in school were studied in a sample of 7137 Norwegian primary and secondary school pupils aged between 10 and 16 years. To study whether additional social disadvantages moderated the…

  1. Effect of nutritive status on Mytilus galloprovincialis pollution biomarkers: Implications for large-scale monitoring programs.

    Science.gov (United States)

    González-Fernández, Carmen; Albentosa, Marina; Campillo, Juan A; Viñas, Lucía; Romero, Diego; Franco, Angeles; Bellas, Juan

    2015-10-01

    Biomarkers have been extensively used in monitoring programs with the aim of assessing the biological effects of pollutants on marine organisms and determining environmental status. Data obtained from these programs are sometimes difficult to interpret due to the large amount of natural variables affecting biological processes, which could act as confounding factors on biomarker responses. The main aim of this work was to identify the effect of one of these variables, the food availability, and consequently, the mussel nutritive status, on biomarker responses. For that purpose, mussels (Mytilus galloprovincialis) were conditioned to three different food rations for 2 months in order to create three mussel nutritive statuses and afterwards, each status was exposed to three nominal concentrations of fluoranthene (FLU) for 3 weeks. A battery of biomarkers was considered in this study to cover a wide range of organism responses, both physiological (scope for growth - SFG) and biochemical (superoxide dismutase - SOD, catalase - CAT, glutathione reductase - GR, glutathione peroxidase - GPx, glutathione-S-transferase - GST and phenoloxidase - PO activities, and lipid membrane peroxidation - LPO). The results obtained, evidenced that most of the studied biomarkers (SFG, SOD, CAT, GPx, and PO) were strongly affected by mussel nutritive status, showing higher values at lower status, whereas the effect of toxicant was not always evident, masked by the nutritive status effect. This paper demonstrates that toxicants are not the only source of variability modulating pollution biomarkers, and confirms nutritive status as a major factor altering biochemical and physiological biomarkers.

  2. Status of computerized cognitive testing in aging: a systematic review.

    Science.gov (United States)

    Wild, Katherine; Howieson, Diane; Webbe, Frank; Seelye, Adriana; Kaye, Jeffrey

    2008-11-01

    Early detection of cognitive decline in the elderly has become of heightened importance in parallel with the recent advances in therapeutics. Computerized assessment might be uniquely suited to early detection of changes in cognition in the elderly. We present here a systematic review of the status of computer-based cognitive testing, focusing on detection of cognitive decline in the aging population. All studies purporting to assess or detect age-related changes in cognition or early dementia/mild cognitive impairment by means of computerized testing were included. Each test battery was rated on availability of normative data, level of evidence for test validity and reliability, comprehensiveness, and usability. All published studies relevant to a particular computerized test were read by a minimum of two reviewers, who completed rating forms containing the above mentioned criteria. Of the 18 test batteries identified from the initial search, 11 were appropriate to cognitive testing in the elderly and were subjected to systematic review. Of those 11, five were either developed specifically for application with the elderly or have been used extensively with that population. Even within the computerized testing genre, great variability existed in manner of administration, ranging from fully examiner-administered to fully self-administered. All tests had at least minimal reliability and validity data, commonly reported in peer-reviewed articles. However, level of rigor of validity testing varied widely. All test batteries exhibited some of the strengths of computerized cognitive testing: standardization of administration and stimulus presentation, accurate measures of response latencies, automated comparison in real time with an individual's prior performance as well as with age-related norms, and efficiencies of staffing and cost. Some, such as the Mild Cognitive Impairment Screen, adapted complicated scoring algorithms to enhance the information gathered from

  3. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J.; Dicey, B.B.; Mullen, A.A.; Neale, A.C.; Sparks, A.R.; Fontana, C.A.; Carroll, L.D.; Phillips, W.G.; Smith, D.D.; Thome, D.J.

    1992-01-01

    This report describes the Offsite Radiation Safety Program conducted during 1991 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory-Las Vegas. This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ion chambers (PICs); and by biological monitoring of animals, food crops, and humans. Personnel with mobile monitoring equipment are placed in areas downwind from the test site prior to each nuclear weapons test to implement protective actions, provide immediate radiation monitoring, and obtain environmental samples rapidly after any occurrence of radioactivity release. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no radioactivity detected offsite by the various EPA monitoring networks and no exposure above natural background to the population living in the vicinity of the NTS that could be attributed to current NTS activities. Annual and long-term trends were evaluated in the Noble Gas, Tritium, Milk Surveillance, Biomonitoring, TLD, PIC networks, and the Long-Term Hydrological Monitoring Program.

  4. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    BARNES, D.A.

    2000-06-01

    The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  5. Field test of a post-closure radiation monitor

    Energy Technology Data Exchange (ETDEWEB)

    Reed, S.E. [Babcock & Wilcox, Alliance, OH (United States); Christy, C.E. [Department of Energy, Morgantown, WV (United States); Heath, R.E. [FERMCO, Cincinnati, OH (United States)

    1995-10-01

    The DOE is conducting remedial actions at many sites contaminated with radioactive materials. After closure of these sites, long-term subsurface monitoring is typically required by law. This monitoring is generally labor intensive and expensive using conventional sampling and analysis techniques. The U.S. Department of Energy`s Morgantown Energy Technology Center (METC) has contracted with Babcock and Wilcox to develop a Long-Term Post-Closure Radiation Monitoring System (LPRMS) to reduce these monitoring costs. The system designed in Phase I of this development program monitors gamma radiation using a subsurface cesium iodide scintillator coupled to above-ground detection electronics using optical waveguide. The radiation probe can be installed to depths up to 50 meters using cone penetrometer techniques, and requires no downhole electrical power. Multiplexing, data logging and analysis are performed at a central location. A prototype LPRMS probe was built, and B&W and FERMCO field tested this monitoring probe at the Fernald Environmental Management Project in the fall of 1994 with funding from the DOE`s Office of Technology Development (EM-50) through METC. The system was used measure soil and water with known uranium contamination levels, both in drums and in situ depths up to 3 meters. For comparison purposes measurements were also performed using a more conventional survey probe with a sodium iodide scintillator directly butt-coupled to detection electronics.

  6. Development and testing of a transparent membrane biofouling monitor

    KAUST Repository

    Dreszer, C.

    2014-01-02

    A modified version of the membrane fouling simulator (MFS) was developed for assessment of (i) hydraulic biofilm resistance, (ii) performance parameters feed-channel pressure drop and transmembrane pressure drop, and (iii) in situ spatial visual and optical observations of the biofilm in the transparent monitor, e.g. using optical coherence tomography. The flow channel height equals the feed spacer thickness enabling operation with and without feed spacer. The effective membrane surface area was enlarged from 80 to 200 cm2 by increasing the monitor width compared to the standard MFS, resulting in larger biomass amounts for analysis. By use of a microfiltration membrane (pore size 0.05 μm) in the monitor salt concentration polarization is avoided, allowing operation at low pressures enabling accurate measurement of the intrinsic hydraulic biofilm resistance. Validation tests on e.g. hydrodynamic behavior, flow field distribution, and reproducibility showed that the small-sized monitor was a representative tool for membranes used in practice under the same operating conditions, such as spiral-wound nanofiltration and reverse osmosis membranes. Monitor studies with and without feed spacer use at a flux of 20 L m-2 h-1 and a cross-flow velocity of 0.1 m s-1 clearly showed the suitability of the monitor to determine hydraulic biofilm resistance and for controlled biofouling studies. © 2013 Balaban Desalination Publications. All rights reserved.

  7. Hanford coring bit temperature monitor development testing results report

    Energy Technology Data Exchange (ETDEWEB)

    Rey, D.

    1995-05-01

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks.

  8. [History and present status of butterfly monitoring in Europe and related development strategies for China].

    Science.gov (United States)

    Fang, Li-Jun; Xu, Hai-Gen; Guan, Jian-Ling

    2013-09-01

    Butterfly is an important bio-indicator for biodiversity monitoring and ecological environment assessment. In Europe, the species composition, population dynamics, and distribution pattern of butterfly have been monitored for decades, and many long-term monitoring schemes with international effects have been implemented. These schemes are aimed to assess the regional and national variation trends of butterfly species abundance, and to analyze the relationships of this species abundance with habitat, climate change, and other environmental factors, providing basic data for researching, protecting, and utilizing butterfly resources and predicting environmental changes, and playing important roles in the division of butterfly' s threatened level, the formulation of related protection measures, and the protection and management of ecological environment. This paper reviewed the history and present status of butterfly monitoring in Europe, with the focus on the well-known long-term monitoring programs, e. g. , the UK Butterfly Monitoring Scheme and the Germany and European Union Butterfly Monitoring Scheme. Some specific proposals for conducting butterflies monitoring in China were suggested.

  9. Continuous EEG monitoring in the evaluation of non-convulsive seizures and status epilepticus

    Directory of Open Access Journals (Sweden)

    Murthy J

    2004-10-01

    Full Text Available Non-convulsive seizures (NCSzs and non-convulsive status epilepticus (NCSE occur in a substantial proportion of patients with acute brain injury. These acute seizure disorders are often unrecognized and under-diagnosed. Seizure semiology of NCSz is too subtle clinically to be noticed. Most often, mental status impairment is the presenting feature. Changes in the functions of the thalamo-cortical system in patients with impaired consciousness can be detected by continuous EEG (cEEG monitoring. cEEG monitoring allows detection of the changes at a reversible stage, often when there are no clinical indications of such phenomena. In addition EEG provides reasonable spatial resolution and excellent temporal resolution. This makes cEEG an excellent method for supplementing single or serial recordings in the detection of NCSzs and NCSE. Recent advances in digital EEG have made cEEG monitoring in the neurological intensive care unit (NICU technically feasible. Current evidence suggests that the common clinical denominator associated with electrographic seizures or NCSzs is mental status impairment. In NCSE, the duration of ictal activity and the time of delay to diagnosis are independent predictors of poor outcome. It will be prudent to do cEEG monitoring in any patient with impaired consciousness either in the setting of acute brain injury or with no clear explanation to detect NCSzs/NCSE. Early recognition and timely intervention is likely to be associated with good outcomes.

  10. USE OF SILICON CARBIDE MONITORS IN ATR IRRADIATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    K. L. Davis; B. Chase; T. Unruh; D. Knudson; J. L. Rempe

    2012-07-01

    In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, the ATR will support basic and applied nuclear research and development and help address the nation's energy security needs. In support of this new program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance sensors provided in irradiation locations where instrumentation leads cannot be included, such as drop-in capsule and Hydraulic Shuttle Irradiation System (HSIS) or 'rabbit' locations. For example, silicon carbide (SiC) monitors are now available to detect peak irradiation temperatures between 200°C and 800°C. Using a resistance measurement approach, specialized equipment installed at INL's High Temperature Test Laboratory (HTTL) and specialized procedures were developed to ensure that accurate peak irradiation temperature measurements are inferred from SiC monitors irradiated at the ATR. Comparison examinations were completed by INL to demonstrate this capability, and several programs currently rely on SiC monitors for peak temperature detection. This paper discusses the use of SiC monitors at the ATR, the process used to evaluate them at the HTTL, and presents representative measurements taken using SiC monitors.

  11. Tank Monitoring and Control Sys (TMACS) Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    WANDLING, R.R.

    1999-11-08

    The purpose of this document is to describe tests performed to validate Revision 11.2 of the TMACS Monitor and Control System (TMCACS) and verify that the software functions as intended by design. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  12. Microbial monitoring of crewed habitats in space-current status and future perspectives.

    Science.gov (United States)

    Yamaguchi, Nobuyasu; Roberts, Michael; Castro, Sarah; Oubre, Cherie; Makimura, Koichi; Leys, Natalie; Grohmann, Elisabeth; Sugita, Takashi; Ichijo, Tomoaki; Nasu, Masao

    2014-09-17

    Previous space research conducted during short-term flight experiments and long-term environmental monitoring on board orbiting space stations suggests that the relationship between humans and microbes is altered in the crewed habitat in space. Both human physiology and microbial communities adapt to spaceflight. Microbial monitoring is critical to crew safety in long-duration space habitation and the sustained operation of life support systems on space transit vehicles, space stations, and surface habitats. To address this critical need, space agencies including NASA (National Aeronautics and Space Administration), ESA (European Space Agency), and JAXA (Japan Aerospace Exploration Agency) are working together to develop and implement specific measures to monitor, control, and counteract biological contamination in closed-environment systems. In this review, the current status of microbial monitoring conducted in the International Space Station (ISS) as well as the results of recent microbial spaceflight experiments have been summarized and future perspectives are discussed.

  13. PIP-II Injector Test: Challenges and Status

    Energy Technology Data Exchange (ETDEWEB)

    Derwent, P. F. [Fermilab; Carneiro, J. P. [Fermilab; Edelen, J. [Fermilab; Lebedev, V. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Shemyakin, A. [Fermilab; Steimel, J. [Fermilab

    2016-10-04

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H- superconducting RF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the Injector Test warm front end, including results of the beam commissioning through the installed components, and progress with SRF cryomodules and other systems.

  14. Offsite environmental monitoring report. Radiation monitoring around United States nuclear test areas, calendar year 1982

    Energy Technology Data Exchange (ETDEWEB)

    Black, S. C.; Grossman, R. F.; Mullen, A. A.; Potter, G. D.; Smith, D. D. [comps.

    1983-07-01

    A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify trends, and to provide information to the public. This report summarizes these activities for CY 1982.

  15. Assessing crop N status of fertigated vegetable crops using plant and soil monitoring techniques.

    Science.gov (United States)

    Peña-Fleitas, M T; Gallardo, M; Thompson, R B; Farneselli, M; Padilla, F M

    2015-11-01

    Evaluation of crop N status will assist optimal N management of intensive vegetable production. Simple procedures for monitoring crop N status such as petiole sap [NO 3(-)-N], leaf N content and soil solution [NO 3(-)] were evaluated with indeterminate tomato and muskmelon. Their sensitivity to assess crop N status throughout each crop was evaluated using linear regression analysis against nitrogen nutrition index (NNI) and crop N content. NNI is the ratio between the actual and the critical crop N contents (critical N content is the minimum N content necessary to achieve maximum growth), and is an established indicator of crop N status. Nutrient solutions with four different N concentrations (treatments N1-N4) were applied throughout each crop. Average applied N concentrations were 1, 5, 13 and 22 mmol L(-1) in tomato, and 2, 7, 13 and 21 mmol L(-1) in muskmelon. Respective rates of N were 23, 147, 421 and 672 kg N ha(-1) in tomato, and 28, 124, 245 and 380 kg N ha(-1) in muskmelon. For each N treatment in each crop, petiole sap [NO 3(-)-N] was relatively constant throughout the crop. During both crops, there were very significant (P 1. Relationships between petiole sap [NO 3(-)-N] with crop N content, and leaf N content with both NNI and crop N content had variable slopes and intercept values during the indeterminate tomato and the muskmelon crops. Soil solution [NO 3(-)] in the root zone was not a sensitive indicator of crop N status. Of the three systems examined for monitoring crop/soil N status, petiole sap [NO 3(-)-N] is suggested to be the most useful because of its sensitivity to crop N status and because it can be rapidly analysed on the farm.

  16. [Interventional neuroradiology. Drug treatment, monitoring and function tests].

    Science.gov (United States)

    Laurent, A; Gobin, Y P; Launay, F; Aymard, A; Casasco, A; Merland, J J

    1994-04-23

    Specialized monitoring as well as function tests and drug therapy play an ever growing role in neuroradiological procedures. The particular route of administration and the territories involved in neuroradiology require special precautions. Anaesthesia must enable the operators to monitor the central nervous system since the patients must remain totally immobilized for several hours. Catheterization is made safe by careful asepsia and antibiotic prophylaxis and by preventing embolic events, particularly in neuro-cervico-facial interventions where an anticoagulant protocol is important. Arterial spasms can be prevented or cured with calcium inhibitors. The safety of the procedure itself is guaranteed by various function tests including sensitivity to ischaemia using anaesthetic barbiturates, controlled clampings or the lidocaine test. Undesirable effects of both emboli (e.g. toxicity of cyanoacrylate glue) and embolization (e.g. subsequent venous thrombosis) can be prevented by adapted anti-inflammatory drugs. Herein, we describe the routine monitoring conditions, drugs prescribed and function tests performed at the Therapeutic Angiography Department of the Lariboisière Hospital, Paris.

  17. Multiple criteria analysis of remotely piloted aircraft systems for monitoring the crops vegetation status

    Science.gov (United States)

    Cristea, L.; Luculescu, M. C.; Zamfira, S. C.; Boer, A. L.; Pop, S.

    2016-08-01

    The paper presents an analysis of Remotely Piloted Aircraft Systems (RPAS) used for monitoring the crops vegetation status. The study focuses on two types of RPAS, namely the flying wing and the multi-copter. The following criteria were taken into account: technical characteristics, power consumption, flight autonomy, flight conditions, costs, data acquisition systems used for monitoring, crops area and so on. Based on this analysis, advantages and disadvantages are emphasized offering a useful tool for choosing the proper solution according to the specific application conditions.

  18. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  19. Status of the OPAL microvertex detector and new radiation monitoring and beam dump system

    Science.gov (United States)

    Jong, Sijbrand de

    1998-11-01

    The status of the OPAL Phase III microvertex detector is discussed briefly. This is followed by a more detailed description of the OPAL microvertex detector radiation monitoring and beam dump system. This system measures AC currents induced by radiation on each passing of the beams in silicon diodes mounted close to the microvertex detector front-end electronics. Examples are shown for incidents leading to a beam dump trigger. The integrated radiation dose is also discussed.

  20. Forest health monitoring: national status, trends, and analysis 2015

    Science.gov (United States)

    Kevin M. Potter; Barbara L. Conkling

    2016-01-01

    The annual national report of the Forest Health Monitoring (FHM) Program of the Forest Service, U.S. Department of Agriculture, presents forest health status and trends from a national or multi- State regional perspective using a variety of sources, introduces new techniques for analyzing forest health data, and summarizes results of recently completed Evaluation...

  1. Soil Water Balance and Recharge Monitoring at the Hanford Site - FY09 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Rockhold, Mark L.; Saunders, Danielle L.; Strickland, Christopher E.; Waichler, Scott R.; Clayton, Ray E.

    2009-09-28

    Recharge provides the primary driving force for transporting contaminants from the vadose zone to underlying aquifer systems. Quantification of recharge rates is important for assessing contaminant transport and fate and for evaluating remediation alternatives. This report describes the status of soil water balance and recharge monitoring performed by Pacific Northwest National Laboratory at the Hanford Site for Fiscal Year 2009. Previously reported data for Fiscal Years 2004 - 2008 are updated with data collected in Fiscal Year 2009 and summarized.

  2. Cyber security Considerations for Real Time Physiological Status Monitoring: Threats, Goals, and Use Cases

    Science.gov (United States)

    2016-11-01

    Cyber - security Considerations for Real-Time Physiological Status Monitoring: Threats, Goals, and Use Cases John Holliman, Michael Zhivich, Roger...Spins: Security protocols for sensor networks,” Secaucus, NJ, USA, pp. 521– 534, Sep. 2002. [8] DoD, Resilient Military Systems and the Advanced Cyber ...2012. [10] W. Trappe, R. Howard, and R. S. Moore, “Low-energy security : Limits and opportunities in the internet of things,” IEEE Security Privacy, vol

  3. Design, test, and calibration of an electrostatic beam position monitor

    OpenAIRE

    Maurice Cohen-Solal

    2010-01-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerato...

  4. Current status of radon and radium monitoring at the Federal University of Technology (UTFPR), PR, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Schelin, Hugo R.; Denyak, Valeriy; Barbosa, Laercio; Perna, Allan F.N. [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil)

    2011-07-01

    Numerous and systematic studies performed in different countries for many decades resulted in the explicit conclusion that radon exposure, as well as its progeny, is the main cause of lung cancer among non-smokers. All three natural radon isotopes ({sup 222}Rn, {sup 220}Rn and {sup 219}Rn) are produced in the three principal natural radioactive decay chains. Specifically, the {sup 222}Rn is produced by the decay series of {sup 238}U and proceeded from {alpha}-decay of {sup 226}Ra. Current work describes the present status and obtained results concerning indoor radon survey in dwellings, radon in water supply and soil gas tests performed by the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR) within Curitiba urban area. For radon in air activity measurements, it was used polycarbonate etched track detectors such as LEXAN (GE) and CR-39, mounted in diffusion chambers. For soil gas measurements, the experimental setup was based on the Professional Radon Monitor (AlphaGUARD, Genitron/SAPHYMO) connected to the air pump with filter vessels and to specially developed in our Laboratory the Soil Gas Probe. In the case of radon tests in drinking water, the experimental setup was based on the AlphaGUARD Radon monitor and Electronic radon detector RAD7 (Durridge Company, Inc.) connected to special kit of glass vessels through the air pump. Obtained results permitted to identify few dwellings where radon concentration in air was found bigger than 600 Bq/m{sup 3} which is considered as the action level by most of the European Community and the World Health Organization (WHO). In the case of studied artesian wells, collected samples of water presented the average {sup 222}Rn activity about 60 Bq/L which is 6 times bigger than maximum level recommended by USEPA. Some artesian wells presented the radon activity of almost 200 Bq/L. More over, it was identified the radioactivity of radium ({sup 226}Ra) salts which are soluble in water and almost

  5. Fabrication and testing of a prototype handheld electrochemical CO monitor

    Science.gov (United States)

    Rupich, M. W.; Holleck, G. L.; Wise, H. F.; Hachey, J. P.; Dekermendjian, R. L.

    1985-08-01

    A portable carbon monoxide monitoring instrument was developed for use by the gas utility service industry. A promising instrument was designed and tested under laboratory conditions. The instrument uses a stripping voltammetry technique to measure carbon monoxide. Prototype electrochemical sensors were fabricated and tested under a variety of environmental conditions. The sensor can measure carbon monoxide concentrations of greater than 10 ppm in both ambient air and directly in flue gases. A microprocessor based electronic circuitry was designed to allow totally automated operation of the instrument.

  6. Interim-status groundwater monitoring plan for the 216-B-63 trench. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, M.D.

    1995-06-13

    This document outlines the groundwater monitoring plan for interim-status detection-level monitoring of the 216-B-63 Trench. This is a revision of the initial groundwater monitoring plan prepared for Westinghouse Hanford Company (WHC) by Bjornstad and Dudziak (1989). The 216-B-63 Trench, located at the Hanford Site in south-central Washington State, is an open, unlined, earthern trench approximately 1.2 m (4 ft) wide at the bottom, 427 m (1400 ft) long, and 3 m (10 ft) deep that received wastewater containing hazardous waste and radioactive materials from B Plant, located in the 200 East Area. Liquid effluent discharge to the 216-B-63 Trench began in March 1970 and ceased in February 1992. The trench is now managed by Waste Tank Operations.

  7. A brief status on condition monitoring and fault diagnosis in wind energy conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Amirat, Y. [University of Brest, EA 4325 LBMS, 29238 Brest (France); University of Annaba, Electrical Engineering Department, 23000 Annaba (Algeria); Benbouzid, M.E.H.; Turri, S. [University of Brest, EA 4325 LBMS, 29238 Brest (France); Al-Ahmar, E. [University of Brest, EA 4325 LBMS, 29238 Brest (France); Holy Spirit University of Kaslik, Faculty of Sciences and Computer Engineering, BP 446 Jounieh (Lebanon); Bensaker, B. [University of Annaba, Electrical Engineering Department, 23000 Annaba (Algeria)

    2009-12-15

    There is a constant need for the reduction of operational and maintenance costs of Wind Energy Conversion Systems (WECSs). The most efficient way of reducing these costs would be to continuously monitor the condition of these systems. This allows for early detection of the degeneration of the generator health, facilitating a proactive response, minimizing downtime, and maximizing productivity. Wind generators are also inaccessible since they are situated on extremely high towers, which are normally 20 m or more in height. There are also plans to increase the number of offshore sites increasing the need for a remote means of WECS monitoring that eliminates some of the difficulties faced due to accessibility problems. Therefore and due to the importance of condition monitoring and fault diagnosis in WECS (blades, drive trains, and generators), and keeping in mind the need for future research, this paper is intended as a brief status describing different types of faults, their generated signatures, and their diagnostic schemes. (author)

  8. Performance testing of multi-metal continuous emissions monitors

    Energy Technology Data Exchange (ETDEWEB)

    Haas, W.J. [Ames Lab., IA (United States); French, N.B. [Sky+, Inc. (United States); Brown, C.H. [Oak Ridge National Lab., TN (United States); Burns, D.B. [Westinghouse Savannah River Co., Aiken, SC (United States); Lemieux, P.M.; Ryan, J.V. [National Risk Management Research Lab., Research Triangle Park, NC (United States); Priebe, S.J. [Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States); Waterland, L.R. [Acurex Environmental Corp. (United States)

    1997-11-17

    Three prototype multi-metals continuous emissions monitors (CEMs) were tested in April 1996 at the Rotary Kiln Incinerator Simulator facility at the US Environmental Protection Agency (EPA) National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The CEM instruments were: Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES); Laser Induced Breakdown Spectrometry-Atomic Emission Spectroscopy (LIBS); and Laser Spark Spectrometry, another LIBS instrument. The three CEMs were tested simultaneously during test periods in which low, medium, and high concentration levels of seven toxic metals -- antimony, arsenic, beryllium, cadmium, chromium, lead, and mercury -- were maintained under carefully controlled conditions. Two methods were used to introduce the test metals into the flue gas: (1) solution atomization, introducing metal-containing aerosol directly into the secondary combustion burner, and (2) injection of fly ash particulates. The testing addressed four measures of CEM performance: relative accuracy (RA), calibration drift, zero drift, and response time. These were accomplished by comparing the toxic metal analyte concentrations reported by the CEMs to the concentrations measured using the EPA reference method (RM) for the same analytes. Overall, the test results showed the prototype nature of the test CEMs and the clear need for further development. None of the CEMs tested consistently achieved RA values of 20% or less as required by the EPA draft performance specification. Instrument size reduction and automation will also likely need additional attention before multi-metal CEMs systems become commercially available for service as envisioned by regulators and citizens.

  9. Interim Status Groundwater Monitoring Plan for Low-Level Waste Management Areas 1 to 4, RCRA Facilities, Hanford,Washington

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, P Evan

    2004-10-25

    This document describes the monitoring plan to meet the requirements for interim status groundwater monitoring at Hanford Site low-level waste burial grounds as specified by 40 CFR 265, incorporated by reference in WAC 173-303-400. The monitoring will take place at four separate low-level waste management areas in the 200-West and 200-East Areas, in the central part of the site. This plan replaces the previous monitoring plan.

  10. Status of the irradiation test vehicle for testing fusion materials in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H.; Gomes, I.C.; Smith, D.L. [Argonne National Lab., IL (United States); Palmer, A.J.; Ingram, F.W. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Wiffen, F.W. [Dept. of Energy, Germantown, MD (United States). Office of Fusion Energy

    1998-09-01

    The design of the irradiation test vehicle (ITV) for the Advanced Test Reactor (ATR) has been completed. The main application for the ITV is irradiation testing of candidate fusion structural materials, including vanadium-base alloys, silicon carbide composites, and low-activation steels. Construction of the vehicle is underway at the Lockheed Martin Idaho Technology Company (LMITCO). Dummy test trains are being built for system checkout and fine-tuning. Reactor insertion of the ITV with the dummy test trains is scheduled for fall 1998. Barring unexpected difficulties, the ITV will be available for experiments in early 1999.

  11. Testing and monitoring as basis of the dielectric diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Gockenbach, E. [University of Hannover (Germany). Schering Institute of High Voltage Technique and Engineering

    1999-07-01

    The behaviour of the electrical insulating is the main parameter of the maintenance and life time estimation. The diagnostic is based on the knowledge of the insulating material, the measuring technique, the apparatus and the system and asset management. Tests have a defined purpose under given requirements with a clear decision and may be used as a reference for the later diagnostic. Monitoring is the recording of the relevant parameter under service conditions with requirements given by the character of the recorded signal. Diagnostic is the evaluation of the signals, continuously recorded by a monitoring system, based on the knowledge of the reference value and the influence of the recorded parameters on the electrical insulating material. The weighting and judging of the parameters with mathematical algorithms allow to create a self-learning system which can be used for maintenance and life time estimation. (author)

  12. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1993

    Energy Technology Data Exchange (ETDEWEB)

    Chaloud, D.J; Daigler, D.M.; Davis, M.G. [and others

    1996-06-01

    This report describes the Offsite Radiation Safety Program conducted during 1993 by the Environmental Protection Agency`s (EPA`s) Environmental Monitoring Systems Laboratory - Las Vegas (EMSL-LV). This laboratory operates an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs) and using pressurized ionization chambers (PICs); by biological monitoring of foodstuffs including animal tissues and food crops; and by measurement of radioactive material deposited in humans.

  13. Offsite environmental monitoring report: Radiation monitoring around United States nuclear test areas, calendar year 1997

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Hennessey, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1999-01-01

    This report describes the Offsite Radiological Environmental Monitoring Program (OREMP) conducted during 1997 by the US Environmental Protection Agency`s (EPAs), Radiation and Indoor Environments National Laboratory, Las Vegas, Nevada. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling and analyzing milk, water, and air; by deploying and reading thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs) to measure ambient gamma exposure rates with a sensitivity capable of detecting low level exposures not detected by other monitoring methods.

  14. Offsite environmental monitoring report; radiation monitoring around United States nuclear test areas, Calendar Year 1996

    Energy Technology Data Exchange (ETDEWEB)

    Davis, M.G.; Flotard, R.D.; Fontana, C.A.; Huff, P.A.; Maunu, H.K.; Mouck, T.L.; Mullen, A.A.; Sells, M.D.

    1997-08-01

    This report describes the Offsite Radiation Safety Program. This laboratory operated an environmental radiation monitoring program in the region surrounding the Nevada Test Site (NTS) and at former test sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The surveillance program is designed to measure levels and trends of radioactivity, if present, in the environment surrounding testing areas to ascertain whether current radiation levels and associated doses to the general public are in compliance with existing radiation protection standards. The surveillance program additionally has the responsibility to take action to protect the health and well being of the public in the event of any accidental release of radioactive contaminants. Offsite levels of radiation and radioactivity are assessed by sampling milk, water, and air; by deploying thermoluminescent dosimeters (TLDs); and using pressurized ionization chambers (PICs). No nuclear weapons testing was conducted in 1996 due to the continuing nuclear test moratorium. During this period, R and IE personnel maintained readiness capability to provide direct monitoring support if testing were to be resumed and ascertained compliance with applicable EPA, DOE, state, and federal regulations and guidelines. Comparison of the measurements and sample analysis results with background levels and with appropriate standards and regulations indicated that there was no airborne radioactivity from diffusion or resuspension detected by the various EPA monitoring networks surrounding the NTS. There was no indication of potential migration of radioactivity to the offsite area through groundwater and no radiation exposure above natural background was received by the offsite population. All evaluated data were consistent with previous data history.

  15. Hepatitis C Virus Core Antigen Test in Monitoring of Dialysis Patients

    Directory of Open Access Journals (Sweden)

    Gioacchino Li Cavoli

    2012-01-01

    Full Text Available Hepatitis C virus infection is a persistent worldwide public health concern. The prevalence of HCV infection is much higher in patients on chronic haemodialysis (HD than in the general population. HCV infection can detrimentally affect patients throughout the spectrum of chronic kidney disease. Despite the control of blood products, hepatitis C virus transmission is still being observed among patients undergoing dialysis. Detection systems for serum HCV antibodies are insensitive in the acute phase because of the long serological window. Direct detection of HCV depends on PCR test but this test is not suitable for routine screening. Recent studies have highlighted the importance of HCV core antigen detection as an alternative to PCR. Few studies exist about the efficacy of HCV core antigen test in dialysis population. We studied the utility of HCV core antigen test in routine monitoring of virological status of dialysis patients. We screened 92 patients on long-term dialysis both by PCR HCV-RNA and HCV core antigen test. The sensitivity of HCVcAg test was 90%, the specificity 100%, the positive predictive power 100%, the negative predictive power 97%, and the accuracy 97%. We think serological detection of HCV core antigen may be an alternative to NAT techniques for routine monitoring of patients on chronic dialysis.

  16. [Research and implementation of a real-time monitoring system for running status of medical monitors based on the internet of things].

    Science.gov (United States)

    Li, Yiming; Qian, Mingli; Li, Long; Li, Bin

    2014-07-01

    This paper proposed a real-time monitoring system for running status of medical monitors based on the internet of things. In the aspect of hardware, a solution of ZigBee networks plus 470 MHz networks is proposed. In the aspect of software, graphical display of monitoring interface and real-time equipment failure alarm is implemented. The system has the function of remote equipment failure detection and wireless localization, which provides a practical and effective method for medical equipment management.

  17. 1997 Performance Testing of Multi-Metal Continuous Emissions Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Sky +, Inc.

    1998-09-01

    Five prototype and two commercially available multi-metals continuous emissions monitors (CEMs) were tested in September 1997 at the Rotary Kiln Incinerator Simulator facility at the EPA National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The seven CEMs were tested side by side in a long section of duct following the secondary combustion chamber of the RKIS. Two different concentrations of six toxic metals were introduced into the incinerator-approximately 15 and 75 µg/dscm of arsenic, beryllium, cadmium, chromium, lead, and mercury (We also tested for antimony but we are not reporting on it here because EPA recently dropped antimony from the list of metals addressed by the draft MACT rule). These concentrations were chosen to be close to emission standards in the draft MACT rule and the estimated Method Detection Limit (MDL) required of a CEM for regulatory compliance purposes. Results from this test show that no CEMs currently meet the performance specifications in the EPA draft MACT rule for hazardous waste incinerators. Only one of the CEMs tested was able to measure all six metals at the concentrations tested. Even so, the relative accuracy of this CEM varied between 35% and 100%, not 20% or less as required in the EPA performance specification. As a result, we conclude that no CEM is ready for long-term performance validation for compliance monitoring applications. Because sampling and measuring Hg is a recurring problem for multi-metal CEMs as well as Hg CEMs, we recommended that developers participate in a 1998 DOE-sponsored workshop to solve these and other common CEM measurement issues.

  18. Can clinical tests help monitor human papillomavirus vaccine impact?

    Science.gov (United States)

    Meites, Elissa; Lin, Carol; Unger, Elizabeth R; Steinau, Martin; Patel, Sonya; Markowitz, Lauri E; Hariri, Susan

    2013-09-01

    As immunization programs for human papillomavirus (HPV) are implemented more widely around the world, interest is increasing in measuring their impact. One early measurable impact of HPV vaccine is on the prevalence of specific HPV types in a population. In low-resource settings, a potentially attractive strategy would be to monitor HPV prevalence using clinical cervical cancer screening test results to triage specimens for HPV typing. We assessed this approach in a nationally representative population of U.S. females aged 14-59 years. Using self-collected cervico-vaginal swab specimens from 4,150 women participating in the National Health and Nutrition Examination Survey during 2003-2006, we evaluated type-specific HPV prevalence detected by the Roche linear array (LA) research test on all specimens, compared with type-specific HPV prevalence detected by LA conducted only on specimens positive by the digene hybrid capture 2 (HC-2) clinical test. We calculated weighted prevalence estimates and their 95% confidence intervals (CIs), and examined relative type-specific HPV prevalence according to the two testing approaches. The population prevalence of oncogenic HPV vaccine types 16/18 was 6.2% (CI:5.4-7.1) by LA if all specimens were tested, and 2.4% (CI:1.9-3.0) if restricted to positive HC-2. Relative prevalence of individual HPV types was similar for both approaches. Compared with typing all specimens, a triage approach would require testing fewer specimens, but a greater reduction in HPV prevalence or a larger group of specimens would be needed to detect vaccine impact. Further investigation is warranted to inform type-specific HPV monitoring approaches around the world.

  19. Risk and monitoring based indicators of receiving water status: alternative or complementary elements in IWRM?

    Science.gov (United States)

    Völker, J; Richter, S; Borchardt, D; Mohaupt, V

    2013-01-01

    The European Water Framework Directive (WFD) was enacted in the year 2000 with a stepwise approach. After legal implementation in the various member states large efforts were undertaken for the initial characterization of water bodies, risk assessment, to implement extensive monitoring schemes and to develop management plans at different aggregation levels by the year 2010. The initial characterization process and risk assessment had to be finalized by 2004 and delineated water bodies including a typological classification and identified the significant pressures and impacts in a screening procedure. In parallel, monitoring programmes and new biological indicator systems were developed in order to proof and refine the results of the risk assessment with an ecological indicator based assessment in a subsequent step which was finalized in 2009. Although the risk assessment for Germany was based on existing data that were originally collected for other purposes and came from a large variety of environmental or economical sectors, the results differ only slightly from the monitoring and indicator based information with respect to classifications of the 'ecological status' and 'chemical status'. From this result we conclude that a risk assessment based on a careful application and intelligent combination of existing data sources with proven quality allows the recognition of trends and the identification of priorities for action of measures already at an early stage of a management process. However, monitoring schemes and advanced sets of ecological indicators are essential in later management steps both for narrowing uncertainties remaining from the risk assessment and to allow for effect controls of implemented measures. Moreover, these monitoring indicators should differentiate the effects of multiple stressors more factor specific and with respect to ecosystem states and functions. In conclusion, we see risk and indicator based assessments as complementary elements

  20. Fixed-Level Frequency Threshold Testing for Ototoxicity Monitoring.

    Science.gov (United States)

    Rieke, Catherine C; Clavier, Odile H; Allen, Lindsay V; Anderson, Allison P; Brooks, Chris A; Fellows, Abigail M; Brungart, Douglas S; Buckey, Jay C

    2017-03-30

    Hearing loss from ototoxicity is often most pronounced at high frequencies. To improve patient monitoring and compliance, high-frequency testing methods should be short and easy to administer. We evaluated the repeatability and accuracy of a Békésy-like, fixed-level frequency threshold (FLFT) technique. This test takes less than a minute and could provide a rapid and effective way to determine the highest audible frequency. We hypothesized the FLFT test would be repeatable in normal-hearing subjects, and accurate when compared with Békésy fixed-frequency audiometry in the sensitive region for ototoxicity (SRO). Twenty-nine normal-hearing subjects (20 females, 9 males) performed 2 different automated audiometry tests at least 4 times over a period of no less than 3 weeks. Ages ranged from 23 to 35 years (average = 28 years). Subjects completed testing under Sennheiser HDA-200 headsets. Initial fixed-frequency audiometry thresholds were obtained at frequencies ranging from 0.5 to 20 kHz to identify each subject's highest audible frequency, which was used to determine the SRO. The SRO was defined as the seven frequencies at and below the highest audible frequency in 1/6-octave steps. These frequencies were monitored with fixed-frequency audiometry. At each session, the FLFT test was administered at 80 dB SPL. Subjects used a Békésy-style tracking method to determine the frequency threshold. All testing was completed in a sound booth (single wall, Industrial Acoustics Company) using a computerized, laptop-based, system. FLFT repeatability was calculated as the root mean square difference from the first test session. FLFT accuracy was calculated as the difference from the highest audible frequency determined from fixed-frequency audiometry interpolated to 80 dB SPL level. The FLFT average RMSD for intersession variability was 0.05 ± 0.05 octaves. The test showed no learning effect [F(3,78) = 0.7; p = 0.6]. The overall intersession variability for SRO fixed

  1. [Non-invasive assessment used to evaluate the nasal and oral mucosal cytological status in sociohygienic monitoring].

    Science.gov (United States)

    Beliaeva, N N; Ponomareva, O Iu; Aleksandrova, V P; Olesinov, A A; Budarina, O V; Gasimova, Z M

    2009-01-01

    By analyzing their own studies and the results of other studies by other investigators, the authors provide evidence that the noninvasive evaluation of the nasal and oral cytological status is one of techniques for assessing the health status and reflects the organism's state varying with environmental pollution, which enables it to be recommended for sociohygienic monitoring.

  2. Practical tests for monitoring performance, fatigue and recovery in triathletes.

    Science.gov (United States)

    Coutts, Aaron J; Slattery, Katie M; Wallace, Lee K

    2007-12-01

    Few studies have described simple tests which can be used to provide an early warning of overreaching. The purpose of this study was to examine selected practical tests for monitoring changes in performance, fatigue and recovery of endurance athletes. Sixteen male triathletes were randomly assigned into matched groups. The normal training (NT) and intensified training (IT) groups completed 4 weeks of training followed by a 2-week taper. Physiological measures were taken pre- and post-overload and post-taper periods during an incremental treadmill test to exhaustion. Performance was assessed weekly using a 3-km run time trial (3 kmTT). Five-bound jump for distance (5BT) and submaximal running heart rate (HR(submax)) test were measured twice weekly and the Daily Analyses of Life Demands for Athletes (DALDA) were recorded. During the overload training period, the IT group completed approximately 290% more training load than the NT group (ptaper, the IT group improved 3 kmTT. In contrast, the performance, physiological and psychological markers of NT group remained relatively unchanged throughout the 6-week training period. There were weak significant correlations between weekly changes in 3 kmTT and 5BT (r=-0.37, p<0.01). The DALDA and 5BT may be practical tests for assessing changes in performance, fatigue and recovery of endurance athletes.

  3. Test of GBAS Integrity Monitoring System Using GPS Simulator

    Institute of Scientific and Technical Information of China (English)

    Yun Young-sun; Park Sung-min; Kee Chang-don

    2003-01-01

    In recent years, many countries are developing aircraft navigation systems using GNSS(Global Navigation Satellite System),because GNSS has many technical and economic benefits. International organizations as ICAO(International Civil Aviation Organization) and RTCA(Radio Technical Commission for Aeronautics) set up international standards of GBAS(Ground Based Augmentation System)using GNSS and recommend countries to develop GBAS that is based on the standards. To go with the international stream, Korea Airport Cooperation has also developed GBAS. For evaluating the system,KAC and Seoul National University have performed flight tests of the developed GBAS several times and have concluded that the system has good accuracy enough to be used in aircrafts. At that time, the purpose of tests was focused on accuracy of GBAS. But integrity of the system which is important for safety of aircrafts was not tested sufficiently,because it is impossible to make erroneous situations of real GPS signals. So, at this time, we used GPS simulator which can generate GPS signals with satellite failure scenarios. The GPS simulator used in this test generates GPS signals by the scenarios organized in advance.The scenarios can include pseudorange and carrier phase error, parity error and etc. So we organized several scenarios which can includes potential errors of GPS signals and many possible cases for testing the system effectively and accurately. And we tested integrity function of the GBAS system by using GPS signals generated by the simulator.This paper introduces the implemented integrity monitoring system and algorithms used in the tests. And it describes the scenarios of satellite failure. Finally, this paper shows the results of tests.

  4. Annual Report of the Integrated Status and Effectiveness Monitoring Program: Fiscal Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Terraqua, Inc. (Wauconda, WA)

    2009-07-20

    This document was created as an annual report detailing the accomplishments of the Integrated Status and Effectiveness Monitoring Program (ISEMP) in the Upper Columbia Basin in fiscal year 2008. The report consists of sub-chapters that reflect the various components of the program. Chapter 1 presents a report on programmatic coordination and accomplishments, and Chapters 2 through 4 provide a review of how ISEMP has progressed during the 2008 fiscal year in each of the pilot project subbasins: the John Day (Chapter 2), Wenatchee/Entiat (Chapter 3) and Salmon River (Chapter 4). Chapter 5 presents a report on the data management accomplishments in 2008.

  5. Crack propagation monitoring in a full-scale aircraft fatigue test based on guided wave-Gaussian mixture model

    Science.gov (United States)

    Qiu, Lei; Yuan, Shenfang; Bao, Qiao; Mei, Hanfei; Ren, Yuanqiang

    2016-05-01

    For aerospace application of structural health monitoring (SHM) technology, the problem of reliable damage monitoring under time-varying conditions must be addressed and the SHM technology has to be fully validated on real aircraft structures under realistic load conditions on ground before it can reach the status of flight test. In this paper, the guided wave (GW) based SHM method is applied to a full-scale aircraft fatigue test which is one of the most similar test status to the flight test. To deal with the time-varying problem, a GW-Gaussian mixture model (GW-GMM) is proposed. The probability characteristic of GW features, which is introduced by time-varying conditions is modeled by GW-GMM. The weak cumulative variation trend of the crack propagation, which is mixed in time-varying influence can be tracked by the GW-GMM migration during on-line damage monitoring process. A best match based Kullback-Leibler divergence is proposed to measure the GW-GMM migration degree to reveal the crack propagation. The method is validated in the full-scale aircraft fatigue test. The validation results indicate that the reliable crack propagation monitoring of the left landing gear spar and the right wing panel under realistic load conditions are achieved.

  6. Integrated Status and Effectiveness Monitoring Program - Entiat River Snorkel Surveys and Rotary Screw Trap, 2007.

    Energy Technology Data Exchange (ETDEWEB)

    Nelle, R.D.

    2008-01-01

    The USFWS Mid-Columbia River Fishery Resource Office conducted snorkel surveys at 24 sites during the summer and fall periods of 2006 survey periods as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. A total of 37,938 fish from 15 species/genera and an unknown category were enumerated. Chinook salmon were the overall most common fish observed and comprised 15% of fish enumerated followed by rainbow trout (10%) and mountain whitefish (7%). Day surveys were conducted during the summer period 2007 (August), while night surveys were conducted during the fall 2007 (October) surveys. The USFWS Mid-Columbia River Fishery Resource Office (MCFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program (ISEMP) program from August through November of 2007. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 999 wild Oncorhynchus mykiss and 5,107 wild run O. tshawytscha were PIT tagged during the study period. Rotary screw trap efficiencies averaged 22.3% for juvenile O. tshawytscha and 9.0% for juvenile O. mykiss. Rotary screw traps operated 7 days a week and remote capture operations were conducted when flow and temperature regimes permitted. This is third annual progress report to Bonneville Power Administration for the snorkel surveys conducted in the Entiat River as related to long-term effectiveness monitoring of restoration programs in this watershed. The objective of this study is to monitor the fish habitat utilization of planned in-stream restoration efforts in the Entiat River by conducting pre- and post-construction snorkel surveys at selected treatment and control sites.

  7. Structural monitoring via microwave tomography-enhanced GPR: the Montagnole test site

    Science.gov (United States)

    Catapano, Ilaria; Di Napoli, Rosario; Soldovieri, Francesco; Bavusi, Massimo; Loperte, Antonio; Dumoulin, Jean

    2012-08-01

    Structural integrity assessment and monitoring of infrastructures are key factors to prevent and manage crisis events (natural disasters, terrorist attacks and so on) and ensure urban safety. This necessity motivates huge interest towards design, optimization and integration of non-invasive remote and in situ diagnostic techniques. In this framework, ground penetrating radar (GPR) is a well-assessed instrumentation, which allows one to attain information on the inner status of man-made structures while avoiding invasive tests. However, despite its potential, a more widespread use of GPR is actually affected by the difficulties in providing highly informative and easily interpretable images as an outcome of the overall diagnostics procedure. This drawback can be mitigated thanks to the use of microwave tomography (MT) as a data processing tool able to enhance the achievable reconstruction capabilities, and several proofs of its effectiveness have been already shown. In this paper, the potential of the MT approach is investigated in the framework of structural monitoring by an experiment carried out in the Montagnole test site in the French Alps, where the progressive damage of a one-scale concrete beam has been monitored thanks to the integration of several electromagnetic sensing techniques. In this framework, the capability of the MT-enhanced GPR strategy is examined with respect to the possibility of providing information about the damage of the rebar grid of the beam.

  8. Fetal acoustic stimulation test for early intrapartum fetal monitoring.

    Science.gov (United States)

    Goonewardene, M; Hanwellage, K

    2011-03-01

    The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p fetal well being in early labour. It complements the NST and is better than the NST alone.

  9. Status of the NGNP Fuel Experiment AGR-2 Irradiated in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blaine Grover

    2012-10-01

    The United States Department of Energy’s Next Generation Nuclear Plant (NGNP) Advanced Gas Reactor (AGR) Fuel Development and Qualification Program will be irradiating up to seven separate low enriched uranium (LEU) tri-isotopic (TRISO) particle fuel (in compact form) experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). These irradiations and fuel development are being accomplished to support development of the next generation reactors in the United States, and will be irradiated over the next several years to demonstrate and qualify new TRISO coated particle fuel for use in high temperature gas reactors. The goals of the irradiation experiments are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post irradiation examination (PIE) and safety testing. The experiments, which will each consist of at least six separate capsules, will be irradiated in an inert sweep gas atmosphere with individual on-line temperature monitoring and control of each capsule. The sweep gas will also have on-line fission product monitoring on its effluent to track performance of the fuel in each individual capsule during irradiation. The first experiment (designated AGR-1) started irradiation in December 2006 and was completed in November 2009. The second experiment (AGR-2), which utilized the same experiment design as well as control and monitoring systems as AGR-1, started irradiation in June 2010 and is currently scheduled to be completed in April 2013. The design of this experiment and support systems will be briefly discussed, followed by the progress and status of the experiment to date.

  10. Use of a Digital Camera to Monitor the Growth and Nitrogen Status of Cotton

    Directory of Open Access Journals (Sweden)

    Biao Jia

    2014-01-01

    Full Text Available The main objective of this study was to develop a nondestructive method for monitoring cotton growth and N status using a digital camera. Digital images were taken of the cotton canopies between emergence and full bloom. The green and red values were extracted from the digital images and then used to calculate canopy cover. The values of canopy cover were closely correlated with the normalized difference vegetation index and the ratio vegetation index and were measured using a GreenSeeker handheld sensor. Models were calibrated to describe the relationship between canopy cover and three growth properties of the cotton crop (i.e., aboveground total N content, LAI, and aboveground biomass. There were close, exponential relationships between canopy cover and three growth properties. And the relationships for estimating cotton aboveground total N content were most precise, the coefficients of determination (R2 value was 0.978, and the root mean square error (RMSE value was 1.479 g m−2. Moreover, the models were validated in three fields of high-yield cotton. The result indicated that the best relationship between canopy cover and aboveground total N content had an R2 value of 0.926 and an RMSE value of 1.631 g m−2. In conclusion, as a near-ground remote assessment tool, digital cameras have good potential for monitoring cotton growth and N status.

  11. Nutritional status and food security: winter nutrition monitoring in Sarajevo 1993-1994.

    Science.gov (United States)

    Watson, F; Kulenovic, I; Vespa, J

    1995-10-01

    To monitor nutritional status and food security throughout the winter of 1993-1994 in order to provide early warning of any deterioration, identify the nutritionally vulnerable and so enable humanitarian agencies to respond appropriately. Four different household groups were prospectively followed: residents, refugees in collective centres, refugees in private accommodation and elderly living alone (either residents or refugees). Four local communities were purposively selected and two collective centres were randomly selected. Households were randomly selected within each community and collective centre. An additional sample of all elderly inhabitants of the old people's home were nutritionally assessed only. Monitoring was implemented in the besieged city of Sarajevo. 143 households with 90 children (children (six months to 12 years) and body mass index (BMI) in adults and the elderly were calculated. While the nutritional status of adults and children consistently remained normal, high levels of undernutrition were detected among the elderly ranging from 16% to 21% (BMI disaster in Sarajevo over the winter 1993-1994, there were signs that capacity to cope was weakening in some groups. The elderly were identified as the most nutritionally vulnerable due to sickness, cold, stress and problems related to food preparation. The most food insecure group were refugees in collective centres who were highly dependent on food aid, were less likely to have relatives outside Sarajevo to support them, had fewer possessions to sell and were least likely to have gardens.

  12. Forest ecosystem monitoring in Tuscany (Italy: past activities, present status and future perspectives

    Directory of Open Access Journals (Sweden)

    Claudio LEONZIO

    2002-09-01

    Full Text Available Since 1987 the Region of Tuscany has been actively monitoring crown status in its forests, in order to protect them from atmospheric pollution, biotic factors and environmental change. Over this period the Region has performed periodical inventories on crown condition in publicly-owned forests (Level I network and established a network of permanent plots (MON.I.TO., Level II – III to study long-term changes occurring in forest ecosystems. Some of these permanent plots were later included in the national programme CONECOFOR, managed by the Ministry for Policy in Agriculture and Forest. Currently a further development of MON.I.TO. is being implemented, called MONITO III – TOpModel, the aim of which is to broaden the information potential of the monitoring system to include carbon stocks and biodiversity evaluation. This paper provides an up-to-date report on the status of the various surveys and recommends a closer connection between MON.I.TO. and the other regional information systems, especially the Regional Forest Inventory, in order to produce information that may be useful in forest planning and in Sustainable Forest Management.

  13. Distortion-Product Otoacoustic Emission Test Performance for Ototoxicity Monitoring

    Science.gov (United States)

    Reavis, Kelly M.; McMillan, Garnett; Austin, Donald; Gallun, Frederick; Fausti, Stephen A.; Gordon, Jane S.; Helt, Wendy J.; Konrad-Martin, Dawn

    2017-01-01

    Introduction A nonbehavioral method for monitoring ototoxicity in patients treated with cisplatin is needed because patients enduring chemotherapy may not be well or cooperative enough to undergo repeated hearing tests. Distortion-product otoacoustic emissions (DPOAEs) provide a nonbehavioral measure of auditory function that is sensitive to cisplatin exposure. However, interpreting DPOAE findings in the context of ototoxicity monitoring requires that their accuracy be determined in relation to a clinically accepted gold standard test. Objectives Among patients receiving cisplatin for the treatment of cancer, we sought to (1) identify the combination of DPOAE metrics and ototoxicity risk factors that best classified ears with and without ototoxic-induced hearing changes; and (2) evaluate the test performance achieved by the composite measure as well as by DPOAEs alone. Design Odds of experiencing hearing changes at a given patient visit were determined using data collected prospectively from 24 Veterans receiving cisplatin. Pure-tone thresholds were examined within an octave of each subject’s high-frequency hearing limit. DPOAE were collected as a set of four response growth (input/output) functions near the highest f2 frequency that yielded a robust response at L2 = L1 = 65 dB SPL. Logistic regression modeled the risk of hearing change using several DPOAE metrics, drug treatment factors, and other patient factors as independent variables. An optimal discriminant function was derived by reducing the model so that only statistically significant variables were included. Receiver operating characteristic curve analyses were used to evaluate test performance. Results At higher cisplatin doses, ears with better hearing at baseline were more likely to exhibit ototoxic hearing changes than those with poorer hearing. Measures of pre-exposure hearing, cumulative drug dose, and DPOAEs generated a highly accurate discriminant function with a cross-validated area under the

  14. Reliability Tests of the LHC Beam Loss Monitoring FPGA Firmware

    CERN Document Server

    Hajdu, C F; Dehning, B; Jackson, S

    2010-01-01

    The LHC Beam Loss Monitoring (BLM) system is one of the most complex instrumentation systems deployed in the LHC. In addition to protecting the collider, the system also needs to provide a means of diagnosing machine faults and deliver a feedback of losses to the control room as well as to several systems for their setup and analysis. It has to transmit and process signals from almost 4’000 monitors, and has nearly 3 million configurable parameters. In a system of such complexity, firmware reliability is a critical issue. The integrity of the signal chain of the LHC BLM system and its ability to correctly detect unwanted scenarios and thus provide the required protection level must be ensured. In order to analyze the reliability and functionality, an advanced verification environment has been developed to evaluate the performance and response of the FPGA-based data analysis firmware. This paper will report on the numerous tests that have been performed and on how the results are used to quantify the reliabi...

  15. Modular Integrated Monitoring System (MIMS) field test installations

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, R.L.; Waymire, D.R. [Sandia National Labs., Albuquerque, NM (United States); Fuess, D.A. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-07-01

    The MIMS program is funded by the Department of Energy under the Office of Nonproliferation and National Security. The program objective is to develop cost effective, modular, multi-sensor monitoring systems. Both in-plant and ground based sensors are envisioned. It is also desirable to develop sensors/systems that can be fielded/deployed in a rapid fashion. A MIMS architecture was selected to allow modular integration of sensors and systems and is based on LonWorks technology, commercially developed by Echelon Corporation. The first MIMS fieldable hardware was demonstrated at Lawrence Livermore National Laboratory. The field test, known within the DOE as the Item Tracking and Transparency (IT&I) demonstration, involved the collaboration and cooperation of five DOE laboratories (Sandia (SNL), Lawrence Livermore (LLNL), Pacific Northwest (PNL), Los Alamos (LANL), and Oak Ridge (ORNL)). The IT&T demonstration involved the monitoring of special nuclear material as it was transported around the facility utilizing sensors from the participating labs. The scenario was programmed to ignore normal activity in the facility until entry into the room where the material was stored. A second demonstration, which involved three separate scenarios, was conducted at Idaho National Engineering Laboratory (INEL). The participants included representatives from SNL, LLNL, PNL, and INEL. DOE has selected INEL as the long term testbed for MIMS developed sensors, systems, and scenarios. This paper will describe the installation, intended purpose, and results of the field demonstrations at LLNL and INEL under the MIMS program.

  16. The Savannah River Technology Center environmental monitoring field test platform

    Energy Technology Data Exchange (ETDEWEB)

    Rossabi, J.

    1993-03-05

    Nearly all industrial facilities have been responsible for introducing synthetic chemicals into the environment. The Savannah River Site is no exception. Several areas at the site have been contaminated by chlorinated volatile organic chemicals. Because of the persistence and refractory nature of these contaminants, a complete clean up of the site will take many years. A major focus of the mission of the Environmental Sciences Section of the Savannah River Technology Center is to develop better, faster, and less expensive methods for characterizing, monitoring, and remediating the subsurface. These new methods can then be applied directly at the Savannah River Site and at other contaminated areas in the United States and throughout the world. The Environmental Sciences Section has hosted field testing of many different monitoring technologies over the past two years primarily as a result of the Integrated Demonstration Program sponsored by the Department of Energy`s Office of Technology Development. This paper provides an overview of some of the technologies that have been demonstrated at the site and briefly discusses the applicability of these techniques.

  17. Design, test, and calibration of an electrostatic beam position monitor

    Directory of Open Access Journals (Sweden)

    Maurice Cohen-Solal

    2010-03-01

    Full Text Available The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  18. Design, test, and calibration of an electrostatic beam position monitor

    Science.gov (United States)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  19. GROUNDWATER MONITORING: Statistical Methods for Testing Special Background Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Charissa J.

    2004-04-28

    This chapter illustrates application of a powerful intra-well testing method referred as the combined Shewhart-CUSUM control chart approach, which can detect abrupt and gradual changes in groundwater parameter concentrations. This method is broadly applicable to groundwater monitoring situations where there is no clearly defined upgradient well or wells, where spatial variability exists in parameter concentrations, or when groundwater flow rate is extremely slow. Procedures for determining the minimum time needed to acquire independent groundwater samples and useful transformations for obtaining normally distributed data are also provided. The control chart method will be insensitive to detect real changes if a preexisting trend is observed in the background data set. A method and a case study describing how a trend observed in a background data set can be removed using a transformation suggested by Gibbons (1994) are presented to illustrate treatment of a preexisting trend.

  20. Academe defends its role in Test Ban Treaty monitoring

    Science.gov (United States)

    Wakefield, J.

    Recent jockeying for control of congressional seismic research funds has left the U.S. scientific research community uneasy about future cooperation with the federal government in the development of comprehensive nuclear test ban monitoring systems.Even though the language in a Defense authorization bill for fiscal year 1995, which cleared the Senate June 30, will likely be toned down in the House and Senate conference, the “aggressive” maneuvering that ensued to tentatively dispose the bulk of power over the interagency seismic network to the Defense Department, critics say, raises new questions about how science policy decisions are made in the United States and how committed the Congress and some federal agencies are to “reinventing” government under the Clinton-Gore plan. And for now, a hefty chunk of funding for academic seismic research is no longer a sure thing.

  1. Rapid microbiological testing: monitoring the development of bacterial stress.

    Directory of Open Access Journals (Sweden)

    Boris Zavizion

    Full Text Available The ability to respond to adverse environments effectively along with the ability to reproduce are sine qua non conditions for all sustainable cellular forms of life. Given the availability of an appropriate sensing modality, the ubiquity and immediacy of the stress response could form the basis for a new approach for rapid biological testing. We have found that measuring the dielectric permittivity of a cellular suspension, an easily measurable electronic property, is an effective way to monitor the response of bacterial cells to adverse conditions continuously. The dielectric permittivity of susceptible and resistant strains of Escherichia coli and Staphylococcus aureus, treated with gentamicin and vancomycin, were measured directly using differential impedance sensing methods and expressed as the Normalized Impedance Response (NIR. These same strains were also heat-shocked and chemically stressed with Triton X-100 or H(2O(2. The NIR profiles obtained for antibiotic-treated susceptible organisms showed a strong and continuous decrease in value. In addition, the intensity of the NIR value decrease for susceptible cells varied in proportion to the amount of antibiotic added. Qualitatively similar profiles were found for the chemically treated and heat-shocked bacteria. In contrast, antibiotic-resistant cells showed no change in the NIR values in the presence of the drug to which it is resistant. The data presented here show that changes in the dielectric permittivity of a cell suspension are directly correlated with the development of a stress response as well as bacterial recovery from stressful conditions. The availability of a practical sensing modality capable of monitoring changes in the dielectric properties of stressed cells could have wide applications in areas ranging from the detection of bacterial infections in clinical specimens to antibiotic susceptibility testing and drug discovery.

  2. CDC's Prevention Status Reports: Monitoring the Status of Public Health Policies and Practices for Improved Performance and Accountability.

    Science.gov (United States)

    Young, Andrea C; Lowry, Garry; Mumford, Karen; Graaf, Christine

    2017-02-03

    Increasing the adoption and implementation of evidence-based policies and practices is a key strategy for improving public health. Although there is widespread agreement about the importance of implementing evidence-based public health policies and practices, there are gaps between what has been shown to be effective and what is implemented at the state level. The Centers for Disease Control and Prevention (CDC) developed the Prevention Status Reports (PSRs), a performance measurement system, to highlight evidence-based public health policies and practices and catalyze state performance and quality improvement efforts across the nation. CDC selected a set of 10 topics representing some of the most important public health challenges in the nation. Stakeholders, including state health departments and other partners, helped conceptualize the PSRs and informed the development of the PSR framework, which provides an organizational structure for the system. CDC subject matter experts developed criteria for selecting policies and practices, indicators for each policy and practice, and a criteria-based rating system for each indicator. The PSRs were developed for all 50 states and the District of Columbia. The PSRs were developed and serve as a performance measurement system for monitoring the adoption, reach, and implementation fidelity of evidence-based public health policies and practices nationwide. The PSRs include 33 policy and practice indicators across the 10 health topics. They use a simple 3-level rating system-green, yellow, and red-to report the extent to which each state (and the District of Columbia) has implemented the policy or practice in accordance with supporting evidence or expert recommendations. Results from aggregate analyses show positive change or improvement. The PSRs are a unique part of CDC's work to improve the performance and accountability of the public health system, serving as both a monitoring tool and a call to action to improve health

  3. Status of the Stripline Beam Position Monitor developement for the CLIC Drive Beam

    CERN Document Server

    Benot-Morell, A; Wendt, M; Faus-Golfe, A; Nappa, J M; Vilalte, S; Smith, S

    2013-01-01

    In collaboration with SLAC, LAPP and IFIC, a first prototype of a stripline Beam Position Monitor (BPM) for the CLIC Drive Beam and its associated readout electronics has been successfully tested in the CLIC Test Facility linac (CTF3) at CERN. In addition, a modified prototype with downstream terminated striplines is under development to improve the suppression of unwanted RF signal interference. This paper presents the results of the beam tests, and the most relevant aspects for the modified stripline BPM design and its expected improvements.

  4. Integrated Status and Effectiveness Monitoring Program - Entiat River Snorkel Surveys, 2006-2007.

    Energy Technology Data Exchange (ETDEWEB)

    Nelle, R.D.

    2007-10-01

    The USFWS Mid-Columbia River Fishery Resource Office conducted snorkel surveys at 11 sites during the summer 2006 survey period and at 15 sites during fall 2006 and winter 2007 survey periods as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. A total of 39,898 fish from 14 species/genera and an unknown category were enumerated. Chinook salmon were the overall most common fish observed and comprised 19% of fish enumerated followed by mountain whitefish (18%) and rainbow trout (14%). Day and night surveys were conducted during the summer 2006 period (August), while night surveys were conducted during the fall 2006 (October) and winter 2007 (February/March) surveys. This is second annual progress report to Bonneville Power Administration for the snorkel surveys conducted in the Entiat River as related to long-term effectiveness monitoring of restoration programs in this watershed. The objective of this study is to monitor the fish habitat utilization of planned in-stream restoration efforts in the Entiat River by conducting pre- and post-construction snorkel surveys at selected treatment and control sites.

  5. The CTBT's International Monitoring System and On-Site Inspection Capabilities: a Status Report

    Science.gov (United States)

    Zerbo, Lassina

    2017-01-01

    At its 20th anniversary the Comprehensive Nuclear-Test-Ban Treaty has now gathered 183 State Signatories, of which 166 have ratified. But 8 States remain to ratify before we reach entry into force. In the meantime the CTBT verification regime has accumulated two decades worth of experience, and has achieved proven results. The regime includes a global system for monitoring the earth, the oceans and the atmosphere and an on-site inspection (OSI) capability. It uses seismic, hydroacoustic, infrasound and radionuclide technologies to do so. More than 90% of the 337 facilities of the International Monitoring System (IMS) have been installed and are sending data to the International Data Centre (IDC) in Vienna, Austria for processing. These IMS data along with IDC processed and reviewed products are available to all States that have signed the Treaty. The monitoring system has been put to test and demonstrated its effectiveness by detecting, locating and reporting on the DPRK announced nuclear tests in 2006, 2009, 2013 and twice in 2016. In addition to detecting radioxenon consistent with the nuclear tests in 2006 and 2013 the IMS radionuclide network also added value in the response to the tragic events in Fukushima in 2011. We continue to find new civil and scientific applications of the IMS that are made available to the international community to deal with major societal issues such as sustainable development, disaster risk reduction and climate change. OSI capabilities continue to be developed and tested. The Integrated Field Exercise in Jordan in 2014 demonstrated that they have reached a high level of operational readiness. The CTBT has been a catalyst for the development of new scientific fields in particular in the noble gas monitoring technology. CTBTO seeks to continuously improve its technologies and methods through interaction with the scientific community.

  6. Facility effluent monitoring plan for the fast flux test facility

    Energy Technology Data Exchange (ETDEWEB)

    Nickels, J M; Dahl, N R

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in US Department of Energy Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A Facility Effluent Monitoring Plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements.

  7. National status of testing for hypothyroidism during pregnancy and postpartum.

    Science.gov (United States)

    Blatt, Amy J; Nakamoto, Jon M; Kaufman, Harvey W

    2012-03-01

    Hypothyroidism, overt or subclinical, is associated with adverse outcomes for pregnant women and their offspring. Knowledge of current national thyroid testing rates and positivity during pregnancy is limited. The aim of the study was to estimate thyroid testing rate and positivity during pregnancy and postpartum, including testing and positivity rates of thyroperoxidase antibody (TPO Ab) and free T(4) tests in pregnant women with elevated TSH levels (hypothyroid), and in pregnant women having TSH within range (euthyroid). Records from a large, national sample of pregnant women screened from June 2005 through May 2008 were examined. The study included 502,036 pregnant women, for whom gestational age information was available. Testing rates and the prevalence of hypothyroidism during pregnancy and postpartum were measured using assay-specific, trimester-specific reference intervals. Screening and positivity rates of TPO Ab and free T(4) tests were also measured. Of women ages 18 to 40 yr, 23% (117,892 of 502,036) were tested for gestational hypothyroidism (defined as both subclinical and overt hypothyroidism). Of these, 15.5% (18,291 of 117,892) tested positive for gestational hypothyroidism. Twenty-four percent (22,650 of 93,312) of women with TSH within range and 33% (6,072 of 18,291) of women with elevated TSH were also tested for gestational hypothyroxinemia. Gestational hypothyroxinemia was seen in 0.2% (47 of 22,650) of the tested women with TSH within range and was seen in 2.4% (144 of 6,072) of the tested women having elevated TSH; 0.3% (276 of 93,312) of women with TSH within range received a TPO Ab test, and of these, 15% (41 of 276) tested positive; 0.66% (120 of 18,291) of women with elevated TSH received a TPO Ab test, and of these, 65% (78 of 120) tested positive. Only 20.7% (1873 of 9063) of hypothyroid women received thyroid screening within 6 months postpartum; of these, 11.5% (215 of 1873) were diagnosed with postpartum hypothyroidism. Gestational

  8. Status and challenges of residential and industrial non-intrusive load monitoring

    DEFF Research Database (Denmark)

    Adabi, Ali; Mantey, Patrick; Holmegaard, Emil

    2015-01-01

    Non-Intrusive Load Monitoring (NILM) is the process of identification of loads from an aggregate power interface using disaggregation algorithms. This paper identifies the current status, methodologies and challenges of NILM in residential and industrial settings. NILM has advanced substantially...... in recent years due to improvement in algorithms and methodologies. Currently, the important challenges facing residential NILM are inaccessibility of electricity meter high sampling data, and lack of reliable high resolution datasets. For industrial NILM the identification is more challenging due...... to increased number of loads and the variability of equipment type, temporal patterns and industrial secrecy. From our examination of data and its use in NILM, we observe that the number of devices that can be recognized and the training period required to achiever recognition is not only a function...

  9. Image Theory's Compatibility Test and Evaluations of the Status Quo.

    Science.gov (United States)

    Richmond; Bissell; Beach

    1998-01-01

    The research on image theory's concept of progress decisions about either (1) the acceptability of the status quo vis a desired state or (2) the acceptability of movement toward a desired state has been limited to the laboratory. To demonstrate the feasibility of research on nonlaboratory, job-related progress decisions and to develop methods for doing it with minimal intrusion on participant work time, two experiments examined evaluations of the status quo vis a desired state in the context of three organizations: a controller's office, a pretrial services office, and a chain of fast food restaurants. Experiment 1 used fairly elaborate, time consuming methods in the controller's office and pretrial services office to measure the compatibility between participants' images of desirable supervision and their images of current supervision as well as their satisfaction with both supervision and with the organization. In both cases, as compatibility decreased, satisfaction decreased, but satisfaction with the organization appeared to derive from satisfaction with supervision rather than directly from compatibility. Experiment 2 measured the same concepts in the fast food chain using simple, single-item methods, obtaining roughly the same results as Experiment 1, except that it also demonstrated that hope for change can mitigate the effects of incompatibility on satisfaction. These results provide evidence for the role of compatibility in decision making and for the feasibility of using simple methods of measuring compatibility, acceptability, and hope in nonlaboratory research. Copyright 1998 Academic Press.

  10. Recommendations for Optimizing Tuberculosis Treatment: Therapeutic Drug Monitoring, Pharmacogenetics, and Nutritional Status Considerations.

    Science.gov (United States)

    Choi, Rihwa; Jeong, Byeong Ho; Koh, Won Jung; Lee, Soo Youn

    2017-03-01

    Although tuberculosis is largely a curable disease, it remains a major cause of morbidity and mortality worldwide. Although the standard 6-month treatment regimen is highly effective for drug-susceptible tuberculosis, the use of multiple drugs over long periods of time can cause frequent adverse drug reactions. In addition, some patients with drug-susceptible tuberculosis do not respond adequately to treatment and develop treatment failure and drug resistance. Response to tuberculosis treatment could be affected by multiple factors associated with the host-pathogen interaction including genetic factors and the nutritional status of the host. These factors should be considered for effective tuberculosis control. Therefore, therapeutic drug monitoring (TDM), which is individualized drug dosing guided by serum drug concentrations during treatment, and pharmacogenetics-based personalized dosing guidelines of anti-tuberculosis drugs could reduce the incidence of adverse drug reactions and increase the likelihood of successful treatment outcomes. Moreover, assessment and management of comorbid conditions including nutritional status could improve anti-tuberculosis treatment response.

  11. Status Report on the NBME's Computer-Based Testing.

    Science.gov (United States)

    Clyman, Stephen G.; Orr, Nancy A.

    1990-01-01

    The process proposed for the development and use of computer-based testing, including simulation and multiple-choice questions, as part of the National Board of Medical Examiners' certification sequence is outlined. Summary reports of first-phase pilot testing in six medical schools are appended. (MSE)

  12. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  13. Data mining spacecraft telemetry: towards generic solutions to automatic health monitoring and status characterisation

    Science.gov (United States)

    Royer, P.; De Ridder, J.; Vandenbussche, B.; Regibo, S.; Huygen, R.; De Meester, W.; Evans, D. J.; Martinez, J.; Korte-Stapff, M.

    2016-07-01

    We present the first results of a study aimed at finding new and efficient ways to automatically process spacecraft telemetry for automatic health monitoring. The goal is to reduce the load on the flight control team while extending the "checkability" to the entire telemetry database, and provide efficient, robust and more accurate detection of anomalies in near real time. We present a set of effective methods to (a) detect outliers in the telemetry or in its statistical properties, (b) uncover and visualise special properties of the telemetry and (c) detect new behavior. Our results are structured around two main families of solutions. For parameters visiting a restricted set of signal values, i.e. all status parameters and about one third of all the others, we focus on a transition analysis, exploiting properties of Poincare plots. For parameters with an arbitrarily high number of possible signal values, we describe the statistical properties of the signal via its Kernel Density Estimate. We demonstrate that this allows for a generic and dynamic approach of the soft-limit definition. Thanks to a much more accurate description of the signal and of its time evolution, we are more sensitive and more responsive to outliers than the traditional checks against hard limits. Our methods were validated on two years of Venus Express telemetry. They are generic for assisting in health monitoring of any complex system with large amounts of diagnostic sensor data. Not only spacecraft systems but also present-day astronomical observatories can benefit from them.

  14. Molecular Testing of Lymphoproliferative Disorders: Current Status and Perspectives

    Directory of Open Access Journals (Sweden)

    Yoon Kyung Jeon

    2017-05-01

    Full Text Available Molecular pathologic testing plays an important role for the diagnosis, prognostication and decision of treatment strategy in lymphoproliferative disease. Here, we briefly review the molecular tests currently used for lymphoproliferative disease and those which will be implicated in clinical practice in the near future. Specifically, this guideline addresses the clonality test for B- and T-cell proliferative lesions, molecular cytogenetic tests for malignant lymphoma, determination of cell-of-origin in diffuse large B-cell lymphoma, and molecular genetic alterations incorporated in the 2016 revision of the World Health Organization classification of lymphoid neoplasms. Finally, a new perspective on the next-generation sequencing for diagnostic, prognostic, and therapeutic purpose in malignant lymphoma will be summarized.

  15. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring.

    Science.gov (United States)

    Peletz, Rachel; Kumpel, Emily; Bonham, Mateyo; Rahman, Zarah; Khush, Ranjiv

    2016-03-02

    Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies) across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO) Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies), served larger populations, operated in urban settings, and had higher water quality budgets (all p water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety.

  16. To What Extent is Drinking Water Tested in Sub-Saharan Africa? A Comparative Analysis of Regulated Water Quality Monitoring

    Directory of Open Access Journals (Sweden)

    Rachel Peletz

    2016-03-01

    Full Text Available Water quality information is important for guiding water safety management and preventing water-related diseases. To assess the current status of regulated water quality monitoring in sub-Saharan Africa, we evaluated testing programs for fecal contamination in 72 institutions (water suppliers and public health agencies across 10 countries. Data were collected through written surveys, in-person interviews, and analysis of microbial water quality testing levels. Though most institutions did not achieve the testing levels specified by applicable standards or World Health Organization (WHO Guidelines, 85% of institutions had conducted some microbial water testing in the previous year. Institutions were more likely to meet testing targets if they were suppliers (as compared to surveillance agencies, served larger populations, operated in urban settings, and had higher water quality budgets (all p < 0.05. Our results indicate that smaller water providers and rural public health offices will require greater attention and additional resources to achieve regulatory compliance for water quality monitoring in sub-Saharan Africa. The cost-effectiveness of water quality monitoring should be improved by the application of risk-based water management approaches. Efforts to strengthen monitoring capacity should pay greater attention to program sustainability and institutional commitment to water safety.

  17. Status of coal ash corrosion resistant materials test program

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, D.K.; Meisenhelter, D.K.; Sikka, V.K.

    1999-07-01

    In November of 1998, Babcock and Wilcox (B and W) began development of a system to permit testing of several advanced tube materials at metal temperatures typical of advanced supercritical steam conditions of 1100 F and higher in a boiler exhibiting coal ash corrosive conditions. The U.S. Department of Energy (DOE), the Ohio Coal Development Office (OCDO), B and W, and First Energy's Ohio Edison jointly fund the project. CONSOL Energy Company is also participating as an advisor. Several materials producers including Oak Ridge National Laboratory (ORNL) contributed advanced materials to the project. The coal-ash corrosion resistant materials test program will provide full scale, in-situ testing of recently developed boiler superheater and reheater tube materials. These newer materials may be capable of operating at higher steam temperatures while resisting external/fire-side corrosion. For high sulfur coal applications, this is a key issue for advanced cycle pulverized coal-fired plants. Fireside corrosion is also a critical issue for many existing plants. Previous testing of high temperature materials in the United States has been based primarily on using laboratory test coupons. The test coupons did not operate at conditions representative of a high sulfur coal-fired boiler. Testing outside of the United States has been with low sulfur coal or natural gas firing and has not addressed corrosion issues. This test program takes place in an actual operating boiler and is expected to confirm the performance of these materials with high sulfur coal. The system consists of three identical sections, each containing multiple pieces of twelve different materials. They are cooled by reheater steam, and are located just above the furnace exit in Ohio Edison's Niles Unit No.1, a 110 MWe unit firing high sulfur Ohio coal. After one year of operation, the first section will be removed for thorough metallurgical evaluation. The second and third sections will operate for

  18. An objective framework to test the quality of candidate indicators of good environmental status

    Directory of Open Access Journals (Sweden)

    Ana M Queiros

    2016-05-01

    Full Text Available Large efforts are on-going within the EU to prepare the Marine Strategy Framework Directive’s (MSFD assessment of the environmental status of the European seas. This assessment will only be as good as the indicators chosen to monitor the eleven descriptors of good environmental status (GEnS. An objective and transparent framework to determine whether chosen indicators actually support the aims of this policy is, however, not yet in place. Such frameworks are needed to ensure that the limited resources available to this assessment optimize the likelihood of achieving GEnS within collaborating states. Here, we developed a hypothesis-based protocol to evaluate whether candidate indicators meet quality criteria explicit to the MSFD, which the assessment community aspires to. Eight quality criteria are distilled from existing initiatives, and a testing and scoring protocol for each of them is presented. We exemplify its application in three worked examples, covering indicators for three GEnS descriptors (1, 5 and 6, various habitat components (seaweeds, seagrasses, benthic macrofauna and plankton, and assessment regions (Danish, Lithuanian and UK waters. We argue that this framework provides a necessary, transparent and standardized structure to support the comparison of candidate indicators, and the decision-making process leading to indicator selection. Its application could help identify potential limitations in currently available candidate metrics and, in such cases, help focus the development of more adequate indicators. Use of such standardized approaches will facilitate the sharing of knowledge gained across the MSFD parties despite context-specificity across assessment regions, and support the evidence-based management of European seas.

  19. Condition Monitoring under In-situ Lubrication Status of Bearing Using Infrared Thermography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Yeon; Hong, Dong Pyo; Yu, Chung Hwan [Chonbuk National University, Jeonju (Korea, Republic of); Kim, Won Tae [Kongju National University, Kongju (Korea, Republic of)

    2010-04-15

    The infrared thermography technology rather than traditional nondestructive methods has benefits with non-contact and non-destructive testings in measuring for the fault diagnosis of the rotating machine. In this work, condition monitoring measurements using this advantage of thermography were proposed. From this study, the novel approach for the damage detection of a rotating machine was conducted based on the spectrum analysis. As results, by adopting the ball bearing used in the rotating machine applied extensively, an spectrum analysis with thermal imaging experiment was performed. Also, as analysing the temperature characteristics obtained from the infrared thermography for in-situ rotating ball bearing under the lubrication condition, it was concluded that infrared thermography for condition monitoring in the rotating machine at real time could be utilized in many industrial fields

  20. The status and prospects of the irradiation tests at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Choo, Kee Nam; Yang, Seong Woo; Park, Sang Jun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The integrity assessment of NPP and the extension of lifetime are being considered as important issue, and so the irradiation tests for the structural materials and fuels of NPP should necessarily be conducted. And, the capability of irradiation test is important because Korea participates in developing SFR and VHTR while the development of future nuclear systems is going on to obtain new energy sources all over the world. To effectively support the R and D for new nuclear systems at HANARO, the advanced irradiation technologies such as high-temperature irradiation, instrumentation, and long-term irradiation are being developed. In addition, the researches on the irradiation characteristics of super-conductor materials and new chemical materials are being progressed as a part of fundamental research. Korea is conducting R and D programs relevant to new nuclear systems including research reactor, future nuclear system such as VHTR, SFR and fusion reactor system. In addition, research on the irradiation characteristics of super-conductor materials and new electronic materials is being conducted as a part of fundamental research. Irradiation tests in HANARO are mostly related to the R and D relevant to the ageing management and safety evaluation of NPP and development of the future nuclear system and production of design data of research reactor. The HANARO irradiation capsule system has been developed and actively utilized for the irradiation testing of fuels and materials. The irradiation tests of materials up to the present have been performed usually at temperatures below 300 .deg. C, at which the RPV of PWR materials is being operated. As the irradiation tests of the materials and fuels for a Gen-IV nuclear system are recently required and the development of new research reactors is going on, the capsules for high- and low-temperature irradiation are being developed at HANARO.

  1. Status of the Combined Third and Fourth NGNP Fuel Irradiations In the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    S. Blaine Grover; David A. Petti; Michael E. Davenport

    2013-07-01

    The United States Department of Energy’s Next Generation Nuclear Plant (NGNP) Advanced Gas Reactor (AGR) Fuel Development and Qualification Program is irradiating up to seven low enriched uranium (LEU) tri-isotopic (TRISO) particle fuel (in compact form) experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). These irradiations and fuel development are being accomplished to support development of the next generation reactors in the United States. The experiments will be irradiated over the next several years to demonstrate and qualify new TRISO coated particle fuel for use in high temperature gas reactors. The goals of the experiments are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post irradiation examination (PIE) and safety testing. The experiments, which will each consist of several independent capsules, will be irradiated in an inert sweep gas atmosphere with individual on-line temperature monitoring and control of each capsule. The sweep gas will also have on-line fission product monitoring on its effluent to track performance of the fuel in each individual capsule during irradiation. The first experiment (designated AGR-1) started irradiation in December 2006 and was completed in November 2009. The second experiment (AGR-2) started irradiation in June 2010 and is currently scheduled to be completed in September 2013. The third and fourth experiments have been combined into a single experiment designated (AGR-3/4), which started its irradiation in December 2011 and is currently scheduled to be completed in April 2014. Since the purpose of this combined experiment is to provide data on fission product migration and retention in the NGNP reactor, the design of this experiment is

  2. Drones for aerodynamic and structural testing /DAST/ - A status report

    Science.gov (United States)

    Murrow, H. N.; Eckstrom, C. V.

    1978-01-01

    A program for providing research data on aerodynamic loads and active control systems on wings with supercritical airfoils in the transonic speed range is described. Analytical development, wind tunnel tests, and flight tests are included. A Firebee II target drone vehicle has been modified for use as a flight test facility. The program currently includes flight experiments on two aeroelastic research wings. The primary purpose of the first flight experiment is to demonstrate an active control system for flutter suppression on a transport-type wing. Design and fabrication of the wing are complete and after installing research instrumentation and the flutter suppression system, flight testing is expected to begin in early 1979. The experiment on the second research wing - a fuel-conservative transport type - is to demonstrate multiple active control systems including flutter suppression, maneuver load alleviation, gust load alleviation, and reduce static stability. Of special importance for this second experiment is the development and validation of integrated design methods which include the benefits of active controls in the structural design.

  3. APALS program status: preproduction flight test results and production implementation

    Science.gov (United States)

    Hvizd, James J.; Dieffenbach, Otto W.

    1996-05-01

    The APALS system is a precision approach and landing system designed to enable low visibility landings at many more airports than now possible. Engineering development of the APALS system began October 1992 culminating in the pre- production Advanced Development Model (ADM) system currently undergoing flight testing. The paper focuses on the Cat III accuracy and integrity requirements defined by ICAO, Annex 10 and the required navigation performance (RNP) tunnel concept. The resulting ADM architecture developed to meet them is described. The primary measurement is made with the aircraft's weather radar and provides range and range rate information to the ADM necessary to update the precision navigation state vector. The system uses stored terrain map data as references for map matching with synthetic aperture radar with synthetic aperture radar maps. A description of the pre-production flight test program is included. Testing is being conducted at six different airports around the country demonstrating system performance in various environmental conditions (precipitation, heavy foliage, sparse terrain, over water and turbulence). ADM flight test results of 131 successful CAT II hand-flown approaches at ALbuquerque, NM and Richmond, VA are presented. Detailed statistical analysis of these results indicate that the APALS system meets the RNP for Cat III.

  4. Monitoring intakes of Pu/Am by external counting. Current status in India

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, R.C.; Surendran, T.; Haridasan, T.K. [Internal Dosimetry Division, Bhabha Atomic Reserch Centre, Mumbai (India)

    2000-05-01

    This paper describes the current status of the direct methods of monitoring intakes of actinides, Pu/Am, by external counting techniques in India. It begins with the brief descriptions of the in vivo monitoring facilities established and a variety of optimised radiation detectors being operated inside the graded lined steel room chamber. Two types of phoswich detectors (200 mm dia) differing in the thicknesses of their primary detectors, are operated with pulse shape discrimination electronics based on pulse shape analyser (ORTEC model 458). The other detection systems are : 51 mm dia coaxial HPGe low energy photon spectrometer, a miniature CdTe and a twin thin NaI(Tl). Over the past several years, these facilities have been rationally utilized for conducting various types of internal monitoring programmes for workers handing Pu/Am. Due emphasis has been given to the Quality Assurance (QA) programmes and thus the accuracy of internal exposure evaluations has been ensured by participating in the international intercomparison studies. These included: a) In vivo calibration experiments based on inhalation of mock Pu i.e. polystyrene particles labelled with {sup 103}Pd - {sup 51}Cr, by human volunteers; b) Calibration measurements on Lawrence Livermore National Laboratory's (LLNL) realistic thorax phantom representing a Caucasian man, under an IAEA-CRP and c) By participating in yet another IAEA-CRP on the calibration of in vivo counting systems for actinides (Pu, Am, U, Th) using a Reference Asian phantom whose physique represented an Asian man of Japanese origin. As both, ICRP and BSS of IAEA recommend the use of latest dose coefficients, the current methodology of evaluating internal exposures to actinides (Pu/Am) is based on the new (ICRP-66) model of the human respiratory tract. For this purpose, the software package LUDEP 2.05 (Lung Dose Evaluation Program) has been standardised for routine use. The use of LUDEP 2.05 for calculating intakes and committed

  5. Status of the Dual-Axis Radiographic Hydrodynamics Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Burns, M.J.; Allison, P.W.; Carlson, R.L.; Downing, J.N.; Moir, D.C.; Shurter, R.P.

    1996-09-01

    The Dual-Axis Radiographic Hydrodynamics Test (DARHT) Facility will employ two electron linear induction accelerators to produce intense, bremsstrahlung x-ray pulses for flash radiography with sub-millimeter spatial resolution of very dense (attentuations>10{sup 5}), dynamic objects. We will produce an intense x-ray pulse using a 19.75-MeV, 3.5-4 kA, 60-ns flattop electron beam focused on a tungsten target. A 3.75-MeV injector with either a cold velvet cathode or a laser-driven photocathode will produce a beam to be accelerated through a series of 64 ferrite-loaded induction cells with solenoid focusing. Accelerator technology demonstrations have been underway for several years at the DARHT Integrated Test Stand and results including beam energy, emittance, and beam breakup measurements are discussed.

  6. Skin prick test reactivity to aeroallergens by filaggrin mutation status

    DEFF Research Database (Denmark)

    Hougaard, M G; Johansen, J D; Linneberg, A

    2014-01-01

    BACKGROUND: Studies have shown that filaggrin gene (FLG) mutations are positively associated with sensitization to aero allergens. We hypothesized that FLG mutations would also have an effect on the mean size of positive skin prick test (SPT) reactions as well as the number of positive reactions...... mutations alone are insufficient to cause secondary sensitization to allergens. The positive association seen in patients must be explained by a combination of further barrier abnormality caused by dermatitis as well as increased allergen exposure....

  7. [Pulmonary function testing in Japan: present status and new developments].

    Science.gov (United States)

    Tojo, Naoko

    2012-09-01

    In 2004, the Japanese Respiratory Society issued an initial set of recommendations on the standardized measurement of the most frequently used tests for pulmonary function, i.e., tests to assess slow vital capacity, forced vital capacity, and single-breath carbon monoxide diffusing capacity. This statement has not been updated, and the prediction equations for pulmonary function testing are not fully established. Thus, the guidelines will need to be periodically updated in accordance with new developments in this rapidly evolving field. Nitric oxide (NO) is now recognized as a biological mediator in animals and humans. The human lung produces NO and exhales it in breath. The fractional nitric oxide (NO) concentration in exhaled breath (FE(NO)) can be quantitatively measured by a simple, safe, and noninvasive procedure as a complementary tool for assessing airway inflammation in airway diseases such as asthma. While the measurement of exhaled NO is standardized for clinical use, FE(NO) measurement is not approved or covered under the public health insurance system in Japan.

  8. Monitoring crop health status at greenhouse scale on the basis of volatiles emitted from the plants: a review

    NARCIS (Netherlands)

    Jansen, R.M.C.; Takayama, K.; Wildt, J.; Hofstee, J.W.; Bouwmeester, H.J.; Henten, van E.J.

    2009-01-01

    This review focuses on the monitoring of crop health status at greenhouse scale, based on the measurement of volatile organic compounds (VOCs) emitted from the plants. The review includes the most important factors that affect the emission of these VOCs from greenhouse crops. Since both, stress

  9. Physical quality status analysis for hypertensive crowd detected in Shanghai national physique monitoring

    Directory of Open Access Journals (Sweden)

    LI He

    2014-04-01

    Full Text Available The aim of this study is to analyze the physical fitness of hypertension group for 20-69 years old hypertension crowd that were checked through Shanghai national physique monitoring in 2010,and to provide scientific basis for making exercise health promotion plans for them.Index test methods are based on “2010 China National Physique Monitoring Handbook” issued by the State Sports General Administration.Overall the detection rate of mild hypertension was 16.8%,moderate to severe hypertension was 4.5%.The excellent and good rate in the national physique monitoring was different between different groups,the rate of normotensive group was the highest,then was the mild hypertensive group,the smallest was the severe hypertensive group.With the increase of blood pressure levels,morphological indexes were increased,and the difference was significant.With the increase of blood pressure,the quiet pulse significantly increased,vital capacity and step index decreased significantly,diathesis indexes were significant difference except for back strength,females′ grip strength and men's pushups.The hypertensive group has obvious physical characteristics and obesity morphology,most of them have abdominal obesity,their performance indicators and some quality parameters are significantly lower than normotensive group.

  10. Acoustic monitoring systems tests at Indian Point Unit 1. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.R.; Rao, G.V.; Craig, J.

    1979-12-01

    This report describes the results of a program to test acoustic monitoring systems on Indian Point Unit No. 1 under actual plant operating conditions, less the reactor core. The two types of systems evaluated were the monitoring of acoustic emissions generated by growing flaws and the monitoring of acoustic signals from leaks.

  11. PC and monitor night status: Power management enabling and manual turn-off

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Bruce; Meier, Alan; Piette, Mary Ann

    1998-07-30

    While office equipment accounts for about 7 percent of commercial building energy use, this reflects considerable energy savings from the use of automatic power management. Most of these savings were gained through the use of low-power modes that meet the criteria of the U.S. EPA's Energy Star program. Despite this success, there are large amounts of additional savings that could be gained if all equipment capable of power management use were enabled and functioning. A considerable portion of equipment is not enabled for power management at all, enabled only partially, or is enabled but prevented from functioning. Additional savings could be gained if more equipment were turned off at night manually. We compiled results from 17 studies from the office equipment literature addressing PCs and monitors. Some factors important for annual energy use, such as power levels, have been documented elsewhere and are not covered. We review methods for estimating office equipment use patterns and energy use, and present findings on night status--power management and manual turn-off rates. In early studies, PC power management was often found to function in 25 percent or less of the Energy Star compliant units (10 percent of all PCs). However, recent assessments have found higher rates, and we estimate that for Energy Star models, 35 percent of PC CPUs and 65 percent of PC monitors are enabled for power management. While the data lack statistical rigor, they can be used to estimate the magnitude of current and potential power management savings, which we did for major types of office equipment. The data also make clear that the topic of enabling rates, and the factors which influence them, deserve greater scrutiny.

  12. Alternatives to animal testing: current status and future perspectives.

    Science.gov (United States)

    Liebsch, Manfred; Grune, Barbara; Seiler, Andrea; Butzke, Daniel; Oelgeschläger, Michael; Pirow, Ralph; Adler, Sarah; Riebeling, Christian; Luch, Andreas

    2011-08-01

    On the occasion of the 20th anniversary of the Center for Alternative Methods to Animal Experiments (ZEBET), an international symposium was held at the German Federal Institute for Risk Assessment (BfR) in Berlin. At the same time, this symposium was meant to celebrate the 50th anniversary of the publication of the book "The Principles of Humane Experimental Technique" by Russell and Burch in 1959 in which the 3Rs principle (that is, Replacement, Reduction, and Refinement) has been coined and introduced to foster the development of alternative methods to animal testing. Another topic addressed by the symposium was the new vision on "Toxicology in the twenty-first Century", as proposed by the US-National Research Council, which aims at using human cells and tissues for toxicity testing in vitro rather than live animals. An overview of the achievements and current tasks, as well as a vision of the future to be addressed by ZEBET@BfR in the years to come is outlined in the present paper.

  13. Current status and opportunities for therapeutic drug monitoring in the treatment of tuberculosis.

    Science.gov (United States)

    Zuur, Marlanka A; Bolhuis, Mathieu S; Anthony, Richard; den Hertog, Alice; van der Laan, Tridia; Wilffert, Bob; de Lange, Wiel; van Soolingen, Dick; Alffenaar, Jan-Willem C

    2016-05-01

    Tuberculosis remains a global health problem and pharmacokinetic variability has been postulated as one of the causes of treatment failure and acquired drug resistance. New developments enable implementation of therapeutic drug monitoring, a strategy to evaluate drug exposure in order to tailor the dose to the individual patient, in tuberculosis treatment. Literature on pharmacokinetics and pharmacodynamics of anti-tuberculosis drugs was explored to evaluate the effect of drug exposure in relation to drug susceptibility, toxicity and efficacy. New, down-sized strategies, like dried blood spot analysis and limited sampling strategies are reviewed. In addition, molecular resistance testing of Mycobacteria tuberculosis, combining a short turn-around time with relevant information on drug susceptibility of the causative pathogen was explored. Newly emerging host biomarkers provide information on the response to treatment. Therapeutic drug monitoring can minimize toxicity and increase efficacy of tuberculosis treatment and prevent the development of resistance. Dried blood spot analysis and limited sampling strategies, can be combined to provide us with a more patient friendly approach. Furthermore, rapid information on drug susceptibility by molecular testing, and information from host biomarkers on the bacteriological response, can be used to further optimize tuberculosis treatment.

  14. Standard-C hydrogen monitoring system acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1994-09-02

    The primary function of the standard-C hydrogen monitoring system (SHMS) is to monitor specifically for hydrogen in the waste tank atmosphere which may also contain (but not be limited to) unknown quantities of air, nitrous oxide, ammonia, water vapor, carbon dioxide, carbon monoxide, and other gaseous constituents. The SHMS will consist of hydrogen specific monitors, a grab sampler to collect samples for laboratory analysis, a gas chromatograph, and the gas sample collection system necessary to support the operation of the instrumentation. This system will be located in a cabinet placed at the tank of interest. The purpose of this document is to demonstrate that the SHMS is constructed as intended by design.

  15. Extraction of Sensitive Bands for Monitoring the Winter Wheat (Triticum aestivum) Growth Status and Yields Based on the Spectral Reflectance

    Science.gov (United States)

    Wang, Chao; Feng, Meichen; Yang, Wude; Ding, Guangwei; Xiao, Lujie; Li, Guangxin; Liu, Tingting

    2017-01-01

    To extract the sensitive bands for estimating the winter wheat growth status and yields, field experiments were conducted. The crop variables including aboveground biomass (AGB), soil and plant analyzer development (SPAD) value, yield, and canopy spectra were determined. Statistical methods of correlation analysis, partial least squares (PLS), and stepwise multiple linear regression (SMLR) were used to extract sensitive bands and estimate the crop variables with calibration set. The predictive model based on the selected bands was tested with validation set. The results showed that the crop variables were significantly correlated with spectral reflectance. The major spectral regions were selected with the B-coefficient and variable importance on projection (VIP) parameter derived from the PLS analysis. The calibrated SMLR model based on the selected wavelengths demonstrated an excellent performance as the R2, TC, and RMSE were 0.634, 0.055, and 843.392 for yield; 0.671, 0.017, and 1.798 for SPAD; and 0.760, 0.081, and 1.164 for AGB. These models also performed accurately and robustly by using the field validation data set. It indicated that these wavelengths retained in models were important. The determined wavelengths for yield, SPAD, and AGB were 350, 410, 730, 1015, 1185 and 1245 nm; 355, 400, 515, 705, 935, 1090, and 1365 nm; and 470, 570, 895, 1170, 1285, and 1355 nm, respectively. This study illustrated that it was feasible to predict the crop variables by using the multivariate method. The step-by-step procedure to select the significant bands and optimize the prediction model of crop variables may serve as a valuable approach. The findings of this study may provide a theoretical and practical reference for rapidly and accurately monitoring the crop growth status and predicting the yield of winter wheat. PMID:28060827

  16. Extraction of Sensitive Bands for Monitoring the Winter Wheat (Triticum aestivum) Growth Status and Yields Based on the Spectral Reflectance.

    Science.gov (United States)

    Wang, Chao; Feng, Meichen; Yang, Wude; Ding, Guangwei; Xiao, Lujie; Li, Guangxin; Liu, Tingting

    2017-01-01

    To extract the sensitive bands for estimating the winter wheat growth status and yields, field experiments were conducted. The crop variables including aboveground biomass (AGB), soil and plant analyzer development (SPAD) value, yield, and canopy spectra were determined. Statistical methods of correlation analysis, partial least squares (PLS), and stepwise multiple linear regression (SMLR) were used to extract sensitive bands and estimate the crop variables with calibration set. The predictive model based on the selected bands was tested with validation set. The results showed that the crop variables were significantly correlated with spectral reflectance. The major spectral regions were selected with the B-coefficient and variable importance on projection (VIP) parameter derived from the PLS analysis. The calibrated SMLR model based on the selected wavelengths demonstrated an excellent performance as the R2, TC, and RMSE were 0.634, 0.055, and 843.392 for yield; 0.671, 0.017, and 1.798 for SPAD; and 0.760, 0.081, and 1.164 for AGB. These models also performed accurately and robustly by using the field validation data set. It indicated that these wavelengths retained in models were important. The determined wavelengths for yield, SPAD, and AGB were 350, 410, 730, 1015, 1185 and 1245 nm; 355, 400, 515, 705, 935, 1090, and 1365 nm; and 470, 570, 895, 1170, 1285, and 1355 nm, respectively. This study illustrated that it was feasible to predict the crop variables by using the multivariate method. The step-by-step procedure to select the significant bands and optimize the prediction model of crop variables may serve as a valuable approach. The findings of this study may provide a theoretical and practical reference for rapidly and accurately monitoring the crop growth status and predicting the yield of winter wheat.

  17. Dose monitoring in radiology departments. Status quo and future perspectives; Dosismonitoring in der Radiologie. Status quo und Zukunftsperspektiven

    Energy Technology Data Exchange (ETDEWEB)

    Boos, J. [Harvard Medical School, Boston, MA (United States). Dept. of Radiology; Duesseldorf Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Meineke, A. [Cerner Healthcare Services, Idstein (Germany); Bethge, O.T.; Antoch, G.; Kroepil, P. [Duesseldorf Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2016-05-15

    The number of computed tomography examinations has continuously increased over the last decades and accounts for a major part of the collective radiation dose from medical investigations. For purposes of quality assurance in modern radiology a systematic monitoring and analysis of dose related data from radiological examinations is mandatory. Various ways of collecting dose data are available today, for example the Digital Imaging and Communication in Medicine - Structured Report (DICOM-SR), optical character recognition and DICOM-modality performed procedure steps (MPPS). The DICOM-SR is part of the DICOM-standard and provides the DICOM-Radiation Dose Structured Report, which is an easily applicable and comprehensive solution to collect radiation dose parameters. This standard simplifies the process of data collection and enables comprehensive dose monitoring. Various commercial dose monitoring software devices with varying characteristics are available today. In this article, we discuss legal obligations, various ways to monitor dose data, current dose monitoring software solutions and future perspectives in regard to the EU Council Directive 2013/59/EURATOM.

  18. Status of the EU test blanket systems safety studies

    Energy Technology Data Exchange (ETDEWEB)

    Panayotov, Dobromir, E-mail: dobromir.panayotov@f4e.europa.eu; Poitevin, Yves; Ricapito, Italo; Zmitko, Milan

    2015-10-15

    Highlights: • TBS safety demonstration files. • Safety functions and related design features – detailed TBS components classifications. • Nuclear analyses, radiation shielding and protection. • TBS radiological waste management strategy and categorization. • Selection and definition of reference accidents scenarios and accidents analyses. - Abstract: The European joint undertaking for ITER and the development of fusion energy (‘Fusion for Energy’ – F4E) provides the European contributions to the ITER international fusion energy research project. Among others it includes also the development, design, technological demonstration and implementation of the European test blanket systems (TBS) in ITER. Currently two EU TBS designs are in the phase of conceptual design – helium-cooled lithium-lead (HCLL) and helium-cooled pebble-bed (HCPB). Safety demonstration is an important part of the work devoted to the achievement of the next key project milestone the conceptual design review. The paper reveals the details of the work on EU TBS safety performed in the last couple of years: update of the TBS safety demonstration files; safety functions and related design features; detailed TBS components classifications; nuclear analyses, radiation shielding and protection; TBS radiological waste management strategy and categorization; selection and definition of reference accidents scenarios, and accidents analyses. Finally the authors share the information on on-going and planned future EU TBS safety activities.

  19. Socioeconomic Status of Parents and the Achievement of Children on Readiness for School Tests

    Directory of Open Access Journals (Sweden)

    Anela Hasanagic

    2015-07-01

    Full Text Available Socioeconomic status is often determined like the academic background of parents, and it can be determined like the place of living, village or town, city, as well. Socioeconomic status is an important factor in many aspects of living as in academic achievement as well. Problem in this research paper was to examine whether there are differences between children from different socio-economic status (level of education of parents and between children from villages and towns, on Readiness for school tests. The sample was constituted 296 kids, half from villages, and half from towns in Bosnia and Herzegovina. Tests that were used are: Differences test, Similarities test, Numerical test, Trace test, Knowledge Test, Questionnaire for measuring socio-emotional maturity, and Goodenough's Draw-a-Man Test. Results show that there are statistically significant differences between children from different socio-economic background. Children whose parents are low educated have lower results on Readiness for school test, comparing with children whose parents have finished high school or university level. There were differences between village and town children only on Goodenough's Draw-a-Man Test and on Similarity test, while on other instruments place of living was not important factor for achievement on Readiness for School Test.

  20. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    NARCIS (Netherlands)

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human

  1. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    NARCIS (Netherlands)

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human sk

  2. Comparison of a monoclonal antigen stool test (Hp StAR) with the 13C-urea breath test in monitoring Helicobacter pylori eradication therapy

    Institute of Scientific and Technical Information of China (English)

    Francesco Perri; Michele Quitadamo; Rosalba Ricciardi; Ada Piepoli; Rosa Cotugno; Annamaria Gentile; Alberto Pilotto; Angelo Andriulli

    2005-01-01

    AIM: To evaluate the agreement between a mAb-based stool test (HP StAR) and the urea breath test (UBT) in monitoring (H pylori) infection after eradication therapy.METHODS: Patients with discordant results on UBT and Hp StAR underwent endoscopy with biopsies for rapid urease test, culture, and histology to confirm H pylori status.RESULTS: Among 250 patients (50±14 years), 240 (96.0%) had concordant UBT and Hp StAR tests with a significant correlation between DOB and A values (R = 0.87; P<0.0001).The remaining 10 (4.0%) patients had discordant tests (positive Hp StAR and negative UBT) with the Hp StAR inaccurate in five cases (false positive) and UBT inaccurate in the other five cases (false negative). The "maximal expected" sensitivity, specificity, +PV, -PV, +LR, and -LR were 91%, 100%, 100%, 97.4%, ∞, and 8.2 respectively,for the UBT, and 100%, 97.4%, 91%, 100%, 38.8, and 0,respectively, for the Hp StAR. Overall accuracy for both tests was 98%.CONCLUSION: Both the UBT and the Hp StAR are equally accurate in monitoring H pylori infection. Nowadays,the choice of the "best" non-invasive H pylori test in the post-treatment setting should be done not only in terms of diagnostic accuracy but also in view of cost and local facilities.

  3. Status of the cold test facility for the JT-60SA tokamak toroidal field coils

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Maksoud, Walid, E-mail: walid.abdelmaksoud@cea.fr; Bargueden, Patrick; Bouty, André; Dispau, Gilles; Donati, André; Eppelle, Dominique; Genini, Laurent; Guiho, Patrice; Guihard, Quentin; Joubert, Jean-Michel; Kuster, Olivier; Médioni, Damien; Molinié, Frédéric; Sinanna, Armand; Solenne, Nicolas; Somson, Sébastien; Vieillard, Laurence

    2015-10-15

    Highlights: • The 5 K cryogenic loop includes a 500 W refrigerator and a She cold pump. • The coils are energized thanks to a 25.7 kA power supply and HTS current leads. • Temperature margin tests between 5 K and 7.5 K will be made on each coil. • A magnet safety system protects each double pancake of the coil in case of quench. • Instrumentation is monitored on a 1 Hz to 10 kHz fast acquisition system. - Abstract: JT-60SA is a fusion experiment which is jointly constructed by Japan and Europe and which shall contribute to the early realization of fusion energy, by providing support to the operation of ITER, and by addressing key physics issues for ITER and DEMO. In order to achieve these goals, the existing JT-60U experiment will be upgraded to JT-60SA by using superconducting coils. The 18 TF coils of the JT-60SA device will be provided by European industry and tested in a Cold Test Facility (CTF) at CEA Saclay. The coils will be tested at the nominal current of 25.7 kA and will be cooled with supercritical helium between 5 K and 7.5 K to check the temperature margin against a quench. The main objective of these tests is to check the TF coils performance and hence mitigate the fabrication risks. The most important components of the facility are: a 11.5 m × 6.5 m large cryostat in which the TF coils will be thermally insulated by vacuum; a 500 W helium refrigerator and a valve box to cool the coils down to 5 K and circulate 24 g/s of supercritical helium through the winding pack and through the casing; a power supply and HTS current leads to energize the coil; the control and instrumentation equipment (sensors, PLC's, supervision system, fast data acquisition system, etc.) and the Magnet Safety System (MSS) that protects the coils in case of quench. The paper will give an overview of the design of this large facility and the status of its realization.

  4. Bayesian-based Project Monitoring: Framework Development and Model Testing

    Directory of Open Access Journals (Sweden)

    Budi Hartono

    2015-12-01

    Full Text Available During project implementation, risk becomes an integral part of project monitoring. Therefore. a tool that could dynamically include elements of risk in project progress monitoring is needed. This objective of this study is to develop a general framework that addresses such a concern. The developed framework consists of three interrelated major building blocks, namely: Risk Register (RR, Bayesian Network (BN, and Project Time Networks (PTN for dynamic project monitoring. RR is used to list and to categorize identified project risks. PTN is utilized for modeling the relationship between project activities. BN is used to reflect the interdependence among risk factors and to bridge RR and PTN. A residential development project is chosen as a working example and the result shows that the proposed framework has been successfully applied. The specific model of the development project is also successfully developed and is used to monitor the project progress. It is shown in this study that the proposed BN-based model provides superior performance in terms of forecast accuracy compared to the extant models.

  5. Data acquisition for low-temperature geothermal well tests and long-term monitoring. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  6. Data acquisition for low-temperature geothermal well tests and long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  7. Data Acquisition for Low-Temperature Geothermal Well Tests and Long-Term Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-03-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  8. On-line monitoring of milk electrical conductivity by fuzzy logic technology to characterise health status in dairy goats

    Directory of Open Access Journals (Sweden)

    Mauro Zaninelli

    2014-04-01

    Full Text Available Intramammary infection affects the quality and quantity of dairy goat milk. Health status (HS and milk quality can be monitored by electrical conductivity (EC. The aim of the study was to determine the detection potential of EC when measured on-line on a daily basis and compared with readings from previous milkings. Milk yields (MYs were investigated with the same approach. To evaluate these relative traits, a multivariate model based on fuzzy logic technology – which provided interesting results in cows – was used. Two foremilk samples from 8 healthy Saanen goats were measured daily over the course of six months. Bacteriological tests and somatic cells counts were used to define the HS. On-line EC measurements for each gland and MYs were also considered. Predicted deviations of EC and MY were calculated using a moving-average model and entered in the fuzzy logic model. The reported accuracy has a sensitivity of 81% and a specificity of 69%. Conclusions show that fuzzy logic is an interesting approach for dairy goats, since it offered better accuracy than other methods previously published. Nevertheless, specificity was lower than in dairy cows, probably due to the lack of a significant decrease of MY in diseased glands. Still, results show that the detection of the HS characteristics with EC is improved, when measured on-line, daily and compared with the readings from previous milkings.

  9. Initial operation and current status of the Fermilab DZero VMEbus-based hardware control and monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Goodwin, R.; Florian, R.; Johnson, M.; Jones, A.; Shea, M.

    1989-11-01

    DZero is a large colliding beams detector at Fermilab. The control system for this detector includes twenty-five VMEbus-based 68020 computers interconnected using the IEEE-802.5 Token Ring local area network. In operation, the system will monitor about fifteen thousand analog channels and several thousand digital status bits, interfaced to the 68020 computers by the MIL-1553 multiplexed data bus. In addition, the VMEbus control system uses a memory-mapped multi-VMEbus interconnect to download parameters to more than one hundred VMEbus data crates in the experiment. Remote host computers can then read and set memory in the detector crates over the network by accessing memory in the control crates. This is an extremely useful feature during the construction phase, because low level diagnostics and testing of all the detector electronics can be done over the Token Ring network using either IBM-PC compatible computers or the laboratory-wide VAX system. The VMEbus control system hardware is now being installed in the DZero movable counting house. Installation is expected to be complete later this year. 4 refs., 2 figs.

  10. Monitoring stanja kroz testove analize ulja / Condition monitoring through oil analysis tests

    Directory of Open Access Journals (Sweden)

    Sreten R. Perić

    2010-10-01

    . It is inevitable to use an oil analysis programme in the case of motor oils, which provides several advantages: reduction of unscheduled vehicle downtime, improvement of vehicle reliability, help in organizing effectiveness of maintenance schedules, extension of engine life, optimization of oil change intervals and reduction of cost of vehicle maintenance. The paper also gives the results of the experimental research of physical- chemical characteristics of the motor oils sampled from the engines of Mercedes OM 345 vehicles in operational use. It was shown that there is a change in physical-chemical properties of lubrication oils. These changes are in a direct correlation with the state of all the elements of the tribomechanical motor system, i.e. with their functional characteristics. The conclusion based on the realized testing comes at the end of the paper. Introduction As a contact element of the tribomechanical system, lubricant is a carrier of information about the state of the whole system, from the aspect of tribological as well as other ageing processes. Therefore, an analysis of oils, based on a properly defined program, represents a very effective method for monitoring the state of technical systems, which ensures early warning signals of potential problems that could lead to failure and break down of technical systems. Using Oil Analysis programs for engine oils has several benefits: reduction of unscheduled vehicle downtime, improvement of vehicle reliability, help in organizing effectiveness of maintenance schedules, extension of engine life, optimization of oil change intervals and reduction of vehicle maintenance costs. Physico-chemical characteristics of lubricating oils Basic physico-chemical characteristics which determine the quality of oil are: a physical characteristics: viscosity, density, flash point, cloud Point, pour point, volatillity, emulsibillity, deemulsibillity, foaming, air release, viscosity index, etc. b chemical characteristics

  11. Machine Learning and Data Mining for Comprehensive Test Ban Treaty Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S; Vaidya, S

    2009-07-30

    The Comprehensive Test Ban Treaty (CTBT) is gaining renewed attention in light of growing worldwide interest in mitigating risks of nuclear weapons proliferation and testing. Since the International Monitoring System (IMS) installed the first suite of sensors in the late 1990's, the IMS network has steadily progressed, providing valuable support for event diagnostics. This progress was highlighted at the recent International Scientific Studies (ISS) Conference in Vienna in June 2009, where scientists and domain experts met with policy makers to assess the current status of the CTBT Verification System. A strategic theme within the ISS Conference centered on exploring opportunities for further enhancing the detection and localization accuracy of low magnitude events by drawing upon modern tools and techniques for machine learning and large-scale data analysis. Several promising approaches for data exploitation were presented at the Conference. These are summarized in a companion report. In this paper, we introduce essential concepts in machine learning and assess techniques which could provide both incremental and comprehensive value for event discrimination by increasing the accuracy of the final data product, refining On-Site-Inspection (OSI) conclusions, and potentially reducing the cost of future network operations.

  12. The HIE-ISOLDE alignment and monitoring system software and test mock up

    CERN Document Server

    Kautzmann, G; Kadi, Y; Leclercq, Y; Waniorek, S; Williams, L

    2012-01-01

    For the HIE Isolde project a superconducting linac will be built at CERN in the Isolde facility area. The linac will be based on the creation and installation of 2 high- β and 4 low- β cryomodules containing respectively 5 high-β superconducting cavities and 1 superconducting solenoid for the two first ones, 6 low-β superconducting cavities and 2 superconducting solenoids for the four other ones. An alignment and monitoring system of the RF cavities and solenoids placed inside the cryomodules is needed to reach the optimum linac working conditions. The alignment system is based on opto-electronics, optics and precise mechanical instrumentation. The geometrical frame configuration, the data acquisition and the 3D adjustment will be managed using a dedicated software application. In parallel to the software development, an alignment system test mock-up has been built for software validation and dimensional tests. This paper will present the software concept and the development status, and then will describe...

  13. Monitoring protocol for field testing. Monitoring of heating techniques under practical conditions; Monitoringsprotocol voor veldtesten. Monitoring van warmtetechnieken onder praktijkomstandigheden

    Energy Technology Data Exchange (ETDEWEB)

    Fennema, E.; Jansen, C.

    2009-12-15

    Incentivisation of renewable energy requires large-scale implementation of technologies such as heat-cold storage, heat pumps, cogeneration, solar boilers and waste heat utilization. In practice, the performances of such systems often turn out to deviate from the manufacturer's specifications. Therefore it is important to obtain objective data from practice to gain insight in the differences between theoretical and practical performances and items for improvement of various technologies. The aim of monitoring practice is formulated as: 'gaining insight in the energetic performances of heating techniques under practical circumstances by means of monitoring'. Large-scale measuring in a uniform manner requires a monitoring protocol. Such a protocol safeguards the quality, objectivity, uniformity and hence the reliability of the measuring data. [Dutch] Stimulering van duurzame energie vraagt om grootschalige toepassingen van technologieen zoals warmte-koude opslag, warmtepompen, warmtekracht, zonneboilers en restwarmtebenutting. Het blijkt dat de prestaties van dergelijke systemen in de praktijk vaak afwijken van de fabrikantspecificaties. Daarom is het van belang om objectieve praktijkgegevens te verkrijgen waarmee inzicht wordt verkregen in het verschil tussen theoretische en praktische prestaties, en de verbeterpunten van verschillende technologieen. Het doel van praktijkmonitoring is als volgt geformuleerd: via monitoring het inzicht te verkrijgen in de energetische prestaties van warmtetechnieken onder praktijkomstandigheden. Het uitvoeren van grootschalige metingen op een uniforme wijze vereist een monitoring protocol. Zo'n protocol waarborgt de kwaliteit, objectiviteit, uniformiteit en daarmee de betrouwbaarheid van de meetdata.

  14. Development of structural health monitoring techniques using dynamics testing

    Energy Technology Data Exchange (ETDEWEB)

    James, G.H. III [Sandia National Labs., Albuquerque, NM (United States). Experimental Structural Dynamics Dept.

    1996-03-01

    Today`s society depends upon many structures (such as aircraft, bridges, wind turbines, offshore platforms, buildings, and nuclear weapons) which are nearing the end of their design lifetime. Since these structures cannot be economically replaced, techniques for structural health monitoring must be developed and implemented. Modal and structural dynamics measurements hold promise for the global non-destructive inspection of a variety of structures since surface measurements of a vibrating structure can provide information about the health of the internal members without costly (or impossible) dismantling of the structure. In order to develop structural health monitoring for application to operational structures, developments in four areas have been undertaken within this project: operational evaluation, diagnostic measurements, information condensation, and damage identification. The developments in each of these four aspects of structural health monitoring have been exercised on a broad range of experimental data. This experimental data has been extracted from structures from several application areas which include aging aircraft, wind energy, aging bridges, offshore structures, structural supports, and mechanical parts. As a result of these advances, Sandia National Laboratories is in a position to perform further advanced development, operational implementation, and technical consulting for a broad class of the nation`s aging infrastructure problems.

  15. Status of the first NASA EV-I Project, Tropospheric Emissions: Monitoring of Pollution (TEMPO)

    Science.gov (United States)

    Chance, K.; Liu, X.; Suleiman, R. M.; Flittner, D. E.; Al-Saadi, J. A.; Janz, S. J.

    2013-12-01

    TEMPO is the first NASA Earth Venture Instrument. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City to the Canadian tar sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (2 km N/S × 4.5 km E/W at the center of its field of regard). The status of TEMPO including progress in instrument definition and implementation of the ground system will be presented. TEMPO provides a minimally-redundant measurement suite that includes all key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the inherent high variability in the diurnal cycle of emissions and chemistry. The small spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO will be delivered in 2017 for integration onto a NASA-selected GEO host spacecraft for launch as early as 2018. It will provide the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available. Additional gases not central to air quality, including BrO, OClO, and IO will also be measured. TEMPO and its Asian (GEMS) and European (Sentinel-4) constellation partners make the first tropospheric trace gas measurements from GEO, building on the heritage of six spectrometers flown in low-earth-orbit (LEO). These LEO instruments measure the needed

  16. Status report on a real time Engine Diagnostics Console for rocket engine exhaust plume monitoring

    Science.gov (United States)

    Bircher, F. E.; Gardner, D. G.; Vandyke, D. B.; Harris, A. B.; Chenevert, D. J.

    1990-01-01

    This paper describes the work done on the Engine Diagnostics Console during the past year of development at Stennis Space Center. The Engine Diagnostics Console (EDC) is a hardware and software package which provides near real time monitoring of rocket engine exhaust plume emissions during ground testing. The long range goal of the EDC development program is to develop an instrument that can detect engine degradation leading to catastrophic failure, and respond by taking preventative measures. The immediate goal for the past year's effort is the ability to process spectral data, taken from a rocket engine's exhaust plume, and to identify in an automated and high speed manner, the elemental species and multielemental materials that are present in the exhaust plume.

  17. Intelligent system for pilot and astronaut Psychophysiological status monitoring and recuperating.

    Science.gov (United States)

    Janicki, Andrzej; -Bogumila Pecyna, S. Maria

    called intelligent computations, and their methodology is called “computational intelligence”. The absence of gravity which causes significant physiological stress with broad biomedical changes generated key problems for researchers and practitioners of aviations and space flight. Following previous experiences we had on the matter, some current results achieved on the bases of FlexComp Infinity/Biograph Infiniti, V6.1™ of Thought Technology ltd. [Janicki, Pecyna, 2014] are underlined. A particular emphasis has been placed on the ability of the distributed parallel computations connected with the sophisticated application of the NASA Autogenic Feedback Training AFTE [PS Cowings, 2011] method combined biofeedback and Autogenic Therapy exercises [WIML-NASA, 2011]. The present paper reports on the results of a serious preliminary experiments addressed especially to space disorientation and/or awareness of reality problem. Keywords: pilot’s decision making process; intelligent a agent; coherency; psychophysiological pilot status; remote monitoring; remote training; synthetic indicators; scientific information system; three-factor utility function; space disorientation;Near-Infrared Hemoencephalography; References: A.Janicki “three-factor utility function” in LabTSI™ Modeling and Simulation Platform, KUL Univ. publication 2011 - in polish, page 95-103 M.B. Pecyna and M. Pokorski "Near-Infrared Hemoencephalography for Monitoring Blood Oxygenation in Prefrontal Cortical Areas in diagnosis and Therapy of Developmental Dyslexia" in "Neurobiology of Respiration" Springer Science+Business Media Dordrecht 2013 page 175 - 180. NASA-WIML Workshop on 2011, Psychophysiological Aspects of Flight Safety In Aerospace Operations, WIML 2011

  18. Monitoring plant water status and rooting depth for precision irrigation in the vineyards of Classic Karst

    Science.gov (United States)

    Savi, Tadeja; Moretti, Elisa; Dal Borgo, Anna; Petruzzellis, Francesco; Stenni, Barbara; Bertoncin, Paolo; Dreossi, Giuliano; Zini, Luca; Martellos, Stefano; Nardini, Andrea

    2017-04-01

    The extreme summer drought and heat waves that occurred in South-Europe in 2003 and 2012 have led to the loss of more than 50% of winery production in the Classic Karst (NE Italy). The irrigation of vineyards in this area is not appropriately developed and, when used, it does not consider the actual water status and needs of plants, posing risks of inappropriate or useless usage of large water volumes. The predicted future increase in frequency and severity of extreme climate events poses at serious risk the local agriculture based on wine business. We monitored seasonal trends of pre-dawn (Ψpd) and minimum (Ψmin) leaf water potential, and stomatal conductance (gL) of 'Malvasia' grapevine in one mature (MV, both in 2015 and 2016) and one young vineyard (YV, in 2016). Moreover, we extracted xylem sap form plant stems and soil water from samples collected in nearby caves, by cryo-vacuum distillation. We also collected precipitation and irrigation water in different months. Oxygen isotope composition (δ18O) of atmospheric, plant, soil and irrigation water was analyzed to get information about rooting depth. In 2015, at the peak of summer aridity, two irrigation treatments were applied according to traditional management practices. The treatments were performed in a sub-area of the MV, followed by physiological analysis and yield measurements at grape harvest. In 2016, the soil water potential (Ψsoil) at 50 cm depth was also monitored throughout the season. Under harsh environmental conditions the apparently deep root system ensured relatively favorable plant water status in both MV and YV and during both growing seasons. The Ψsoil at 50 cm depth gradually decreased as drought progressed, reaching a minimum value of about -1.7 MPa, far more negative than Ψpd recorded in plants (about -0.5 MPa). In July, significant stomatal closure was observed, but Ψmin never surpassed the critical threshold of -1.3 MPa, indicating that irrigation was not needed. The xylem sap

  19. The Status of Honey Bee Health in Italy: Results from the Nationwide Bee Monitoring Network.

    Science.gov (United States)

    Porrini, Claudio; Mutinelli, Franco; Bortolotti, Laura; Granato, Anna; Laurenson, Lynn; Roberts, Katherine; Gallina, Albino; Silvester, Nicholas; Medrzycki, Piotr; Renzi, Teresa; Sgolastra, Fabio; Lodesani, Marco

    2016-01-01

    In Italy a nation-wide monitoring network was established in 2009 in response to significant honey bee colony mortality reported during 2008. The network comprised of approximately 100 apiaries located across Italy. Colonies were sampled four times per year, in order to assess the health status and to collect samples for pathogen, chemical and pollen analyses. The prevalence of Nosema ceranae ranged, on average, from 47-69% in 2009 and from 30-60% in 2010, with strong seasonal variation. Virus prevalence was higher in 2010 than in 2009. The most widespread viruses were BQCV, DWV and SBV. The most frequent pesticides in all hive contents were organophosphates and pyrethroids such as coumaphos and tau-fluvalinate. Beeswax was the most frequently contaminated hive product, with 40% of samples positive and 13% having multiple residues, while 27% of bee-bread and 12% of honey bee samples were contaminated. Colony losses in 2009/10 were on average 19%, with no major differences between regions of Italy. In 2009, the presence of DWV in autumn was positively correlated with colony losses. Similarly, hive mortality was higher in BQCV infected colonies in the first and second visits of the year. In 2010, colony losses were significantly related to the presence of pesticides in honey bees during the second sampling period. Honey bee exposure to poisons in spring could have a negative impact at the colony level, contributing to increase colony mortality during the beekeeping season. In both 2009 and 2010, colony mortality rates were positively related to the percentage of agricultural land surrounding apiaries, supporting the importance of land use for honey bee health.

  20. Circulating tumor cell status monitors the treatment responses in breast cancer patients: a meta-analysis

    Science.gov (United States)

    Yan, Wen-Ting; Cui, Xiang; Chen, Qing; Li, Ya-Fei; Cui, You-Hong; Wang, Yan; Jiang, Jun

    2017-01-01

    Whether circulating tumor cells (CTCs) can be used as an indicator of treatment response in breast cancer (BC) needs to be clarified. We addressed this issue by a meta-analysis. PubMed, EMBase and Cochrane library databases were searched in June 2016. Effect measures were estimated as pooled risk ratio (RR), odds ratio (OR) or mean difference by fixed- or random-effect models, according to heterogeneity of included studies. In total, 50 studies with 6712 patients were recruited. Overall analysis showed that there was a significant reduction of CTC-positive rate (RR = 0.68, 95% CI: 0.61–0.76, P < 0.00001) after treatment. Subgroup analyses revealed that neoadjuvant treatment, adjuvant treatment, metastatic treatment or combination therapy could reduce the CTC-positive rate, but surgery could not; moreover, the reduction was only found in HER2+ or HER2- patients but not in the triple-negative ones. Reduction of CTC-positive rate was associated with lower probability of disease progression (OR = 0.54, 95% CI: 0.33–0.89, P = 0.01) and longer overall survival period (mean difference = 11.61 months, 95% CI: 8.63–14.59, P < 0.00001) as well as longer progression-free survival period (mean difference = 5.07 months, 95% CI: 2.70–7.44, P < 0.0001). These results demonstrate that CTC status can serve as an indicator to monitor the effectiveness of treatments and guide subsequent therapies in BC. PMID:28337998

  1. The Status of Honey Bee Health in Italy: Results from the Nationwide Bee Monitoring Network.

    Directory of Open Access Journals (Sweden)

    Claudio Porrini

    Full Text Available In Italy a nation-wide monitoring network was established in 2009 in response to significant honey bee colony mortality reported during 2008. The network comprised of approximately 100 apiaries located across Italy. Colonies were sampled four times per year, in order to assess the health status and to collect samples for pathogen, chemical and pollen analyses. The prevalence of Nosema ceranae ranged, on average, from 47-69% in 2009 and from 30-60% in 2010, with strong seasonal variation. Virus prevalence was higher in 2010 than in 2009. The most widespread viruses were BQCV, DWV and SBV. The most frequent pesticides in all hive contents were organophosphates and pyrethroids such as coumaphos and tau-fluvalinate. Beeswax was the most frequently contaminated hive product, with 40% of samples positive and 13% having multiple residues, while 27% of bee-bread and 12% of honey bee samples were contaminated. Colony losses in 2009/10 were on average 19%, with no major differences between regions of Italy. In 2009, the presence of DWV in autumn was positively correlated with colony losses. Similarly, hive mortality was higher in BQCV infected colonies in the first and second visits of the year. In 2010, colony losses were significantly related to the presence of pesticides in honey bees during the second sampling period. Honey bee exposure to poisons in spring could have a negative impact at the colony level, contributing to increase colony mortality during the beekeeping season. In both 2009 and 2010, colony mortality rates were positively related to the percentage of agricultural land surrounding apiaries, supporting the importance of land use for honey bee health.

  2. The Status of Honey Bee Health in Italy: Results from the Nationwide Bee Monitoring Network

    Science.gov (United States)

    Bortolotti, Laura; Granato, Anna; Laurenson, Lynn; Roberts, Katherine; Gallina, Albino; Silvester, Nicholas; Medrzycki, Piotr; Renzi, Teresa; Sgolastra, Fabio; Lodesani, Marco

    2016-01-01

    In Italy a nation-wide monitoring network was established in 2009 in response to significant honey bee colony mortality reported during 2008. The network comprised of approximately 100 apiaries located across Italy. Colonies were sampled four times per year, in order to assess the health status and to collect samples for pathogen, chemical and pollen analyses. The prevalence of Nosema ceranae ranged, on average, from 47–69% in 2009 and from 30–60% in 2010, with strong seasonal variation. Virus prevalence was higher in 2010 than in 2009. The most widespread viruses were BQCV, DWV and SBV. The most frequent pesticides in all hive contents were organophosphates and pyrethroids such as coumaphos and tau-fluvalinate. Beeswax was the most frequently contaminated hive product, with 40% of samples positive and 13% having multiple residues, while 27% of bee-bread and 12% of honey bee samples were contaminated. Colony losses in 2009/10 were on average 19%, with no major differences between regions of Italy. In 2009, the presence of DWV in autumn was positively correlated with colony losses. Similarly, hive mortality was higher in BQCV infected colonies in the first and second visits of the year. In 2010, colony losses were significantly related to the presence of pesticides in honey bees during the second sampling period. Honey bee exposure to poisons in spring could have a negative impact at the colony level, contributing to increase colony mortality during the beekeeping season. In both 2009 and 2010, colony mortality rates were positively related to the percentage of agricultural land surrounding apiaries, supporting the importance of land use for honey bee health. PMID:27182604

  3. The SCMC test: a reliable monitor for antispermatozoal antibodies.

    Science.gov (United States)

    Franken, D R; Grobler, S; Pretorius, E

    1988-07-01

    Seventeen couples (13%) were selected from a group of 129 infertile patients according to the following criteria: (i) unexplained infertility for 3 years and (ii) greater than 50% shaking spermatozoa during SCMC testing. The couples were tested for sperm antibodies after a complete diagnostic work-up schedule. Post-coital tests were performed during the first menstrual cycle of the wife, followed by SCMC and sperm antibody titre testing. Ten males and seven females were thus treated with 96 mg methylprednisolone. Nine (52%) of the 17 with sperm antibodies achieved a pregnancy. The results of the SCMC test were in all the cases indicative of the actual sperm antibody titre. Reduction of the antibody titre and a decrease in the percentage of shaking spermatozoa as detected by the SCMC test correlated well with the pregnancy rate amongst the patients.

  4. Psychometric testing of the Duke Activity Status Index in patients with heart failure.

    Science.gov (United States)

    Fan, Xiuzhen; Lee, Kyoung Suk; Frazier, Susan K; Lennie, Terry A; Moser, Debra K

    2015-06-01

    Patients with heart failure (HF) experience difficulty performing activities of daily living. As impaired functional status is adversely associated with outcomes, it is important to accurately evaluate patient functional status. The Duke Activity Status Index (DASI) is a 12-item, self-administered questionnaire to measure functional status. However, its psychometric properties have not been determined in patients with HF. The purpose of this study was to examine the psychometric properties of the DASI in patients with HF. We used data from 297 patients with a diagnosis of HF (age 61±11 years, 31% female) for psychometric testing. Internal consistency reliability of the DASI was high (Cronbach's alpha=0.86). Criterion-related validity was supported by significantly different DASI scores for each New York Heart Association classification. Construct validity was supported by significant correlation of DASI scores with health-related quality of life (r = -0.64), depressive symptoms (r = -0.44), and N-terminal B-type natriuretic peptide (r = -0.14). Our data support the psychometric properties of the DASI as a measure of functional status in patients with HF. This instrument can be used to evaluate functional status and enhance health care provider understanding of functional status related to daily living from the patient perspective. © The European Society of Cardiology 2014.

  5. Distributed Monitoring and Control System of Bearing Test and Inspection Center

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Distributed bearing test center monitoring and controlsystem based on CAN bus is designed in this paper. It canmonitor bearing test process, collect test data, analyze vibrationsignals, extract features of bearing failure and diagnose bearingfaults. The system has been used in a bearing test and inspec-tion center of a bearing plant successfully.

  6. PENERAPAN SISTEM ERP DALAM MEMBUAT PROJECT FEASIBILITY, PROJECT STATUS DAN PROJECT MONITORING PADA PERUSAHAAN DI BIDANG KONTRAKTOR

    Directory of Open Access Journals (Sweden)

    Hendra Alianto

    2013-11-01

    cost reduction, and improvement of business processes, which will result in an increase in the work (productivity to become more efficient and effective. However, practically some organizations have problems on running ERP system, some even fail. Therefore, a strategy is needed to help the information systems project. Making project feasibility, project status and project monitoring ERP system can be used as a guide in the design of the ERP program applications to become more user-friendly and suitable for the organization needs. The ERP system applied to a contracting company will increase productivity and achieve the level of effectiveness and efficiency of the company's operations. Through strategies in making project feasibility, and status monitoring with ERP system will provide a positive contribution to the development and objectives of the company, so as to improve the effectiveness and efficiency in the processing operations.

  7. Test of the LHC DIAMOND Beam Loss Monitors

    CERN Document Server

    Dehning, B; Effinger, E; Pernegger, H; Griesmayer, E

    2011-01-01

    Chemical Vapour Deposition(CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-­radiation environment. Four detectors were configured with fast, radiation-­hard pre-amplifiers with a bandwidth of 2GHz. The readout was via an oscilloscope with a bandwidth of 1GHz and a sampling rate of 5 GSPS. Despite the 250m cable run from the detectors to the oscilloscope, particle losses were resolved with a 2ns rise time, a pulse width of 10ns and a time resolution of 615ps. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2us. Measurements during the LHC start-­up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the LHC RF freq...

  8. The Integrated Status and Effectiveness Monitoring Program : Expansion of Existing Smolt Trapping Program and Steelhead Spawner Surveys : March 1st, 2008 - February 28th, 2009.

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Todd; Tonseth, Michael

    2009-01-01

    The Integrated Status and Effectiveness Monitoring Program (ISEMP - BPA project No.2003-0017) has been created as a cost effective means of developing protocols and new technologies, novel indicators, sample designs, analytical, data management and communication tools and skills, and restoration experiments that support the development of a region-wide Research, Monitoring and Evaluation (RME) program to assess the status of anadromous salmonid populations, their tributary habitat and restoration and management actions. The most straightforward approach to developing a regional-scale monitoring and evaluation program would be to increase standardization among status and trend monitoring programs. However, the diversity of species and their habitat, as well as the overwhelming uncertainty surrounding indicators, metrics, and data interpretation methods, requires the testing of multiple approaches. Thus, the approach ISEMP has adopted is to develop a broad template that may differ in the details among subbasins, but one that will ultimately lead to the formation of a unified RME process for the management of anadromous salmonid populations and habitat across the Columbia River Basin. ISEMP has been initiated in three pilot subbasins, the Wenatchee/Entiat, John Day, and Salmon. To balance replicating experimental approaches with the goal of developing monitoring and evaluation tools that apply as broadly as possible across the Pacific Northwest, these subbasins were chosen as representative of a wide range of potential challenges and conditions, e.g., differing fish species composition and life histories, ecoregions, institutional settings, and existing data. ISEMP has constructed a framework that builds on current status and trend monitoring infrastructures in these pilot subbasins, but challenges current programs by testing alternative monitoring approaches. In addition, the ISEMP is: (1) Collecting information over a hierarchy of spatial scales, allowing for a

  9. An assessment of nondestructive testing technologies for chemical weapons monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T.T.

    1993-05-01

    The US Department of Energy (DOE), with the US Army Chemical Research, Development and Engineering Center (CRDEC) under the sponsorship of the Defense Nuclear Agency (DNA), completed testing of Nondestructive Evaluation (NDE) technology on live agent systems. The tests were conducted at Tooele Army Depot during August 1992. The Nondestructive Evaluation systems were tested for potential use in verifying chemical treaty requirements. Five technologies, two neutron and three acoustic, were developed at DOE laboratories. Two systems from the United Kingdom (one neutron and one acoustic) were also included in the field trials. All systems tested showed the ability to distinguish among the VX, GB, and Mustard. Three of the systems (two acoustic and one neutron) were used by On-Site Inspection Agency (OSIA) personnel.

  10. Testing the seismology-based landquake monitoring system

    Science.gov (United States)

    Chao, Wei-An

    2016-04-01

    I have developed a real-time landquake monitoring system (RLMs), which monitor large-scale landquake activities in the Taiwan using real-time seismic network of Broadband Array in Taiwan for Seismology (BATS). The RLM system applies a grid-based general source inversion (GSI) technique to obtain the preliminary source location and force mechanism. A 2-D virtual source-grid on the Taiwan Island is created with an interval of 0.2° in both latitude and longitude. The depth of each grid point is fixed on the free surface topography. A database is stored on the hard disk for the synthetics, which are obtained using Green's functions computed by the propagator matrix approach for 1-D average velocity model, at all stations from each virtual source-grid due to nine elementary source components: six elementary moment tensors and three orthogonal (north, east and vertical) single-forces. Offline RLM system was carried out for events detected in previous studies. An important aspect of the RLM system is the implementation of GSI approach for different source types (e.g., full moment tensor, double couple faulting, and explosion source) by the grid search through the 2-D virtual source to automatically identify landquake event based on the improvement in waveform fitness and evaluate the best-fit solution in the monitoring area. With this approach, not only the force mechanisms but also the event occurrence time and location can be obtained simultaneously about 6-8 min after an occurrence of an event. To improve the insufficient accuracy of GSI-determined lotion, I further conduct a landquake epicenter determination (LED) method that maximizes the coherency of the high-frequency (1-3 Hz) horizontal envelope functions to determine the final source location. With good knowledge about the source location, I perform landquake force history (LFH) inversion to investigate the source dynamics (e.g., trajectory) for the relatively large-sized landquake event. With providing

  11. Effects of L1 Definitions and Cognate Status of Test Items on the Vocabulary Size Test

    Science.gov (United States)

    Elgort, Irina

    2013-01-01

    This study examines the development and evaluation of a bilingual Vocabulary Size Test (VST, Nation, 2006). A bilingual (English-Russian) test was developed and administered to 121 intermediate proficiency EFL learners (native speakers of Russian), alongside the original monolingual (English-only) version of the test. A comparison of the bilingual…

  12. Monitoring Composites under Bending Tests with Infrared Thermography

    Directory of Open Access Journals (Sweden)

    Carosena Meola

    2012-01-01

    Full Text Available The attention of the present paper is focused on the use of an infrared imaging device to monitor the thermal response of composite materials under cyclic bending. Three types of composites are considered including an epoxy matrix reinforced with either carbon fibres (CFRP or glass fibres (GFRP and a hybrid composite involving glass fibres and aluminium layers (FRML. The specimen surface, under bending, displays temperature variations pursuing the load variations with cooling down under tension and warming up under compression; such temperature variations are in agreement with the bending moment. It has been observed that the amplitude of temperature variations over the specimen surface depends on the material characteristics. In particular, the presence of a defect inside the material affects the temperature distribution with deviation from the usual bending moment trend.

  13. Fast Flux Test Facility Performance Monitoring Management Information August 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1989-09-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate provide one means of monitoring overall plant performance. Overall performance indicators are listed in Table 1. The ``other`` performance indicators, listed in Table 2, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. 27 figs., 2 tabs.

  14. Fast Flux Test Facility Performance Monitoring Management Information April 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D. J.

    1989-05-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the result for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. Overall performance indicators are listed. The ``other`` performance indicators, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. 26 figs., 2 tabs.

  15. Fast flux test facility performance monitoring management information; June 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1989-07-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement.

  16. Fast Flux Test Facility Performance Monitoring Management Information March 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D. J.

    1989-04-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other.`` The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. This report must be reviewed with the understanding that both the design and the mission are different for FFTF compared to commercial power reactors.

  17. Variation in serum biomarkers with sex and female hormonal status: Implications for clinical tests

    NARCIS (Netherlands)

    J.M. Ramsey (Jordan); J.D. Cooper (Jason); B.W.J.H. Penninx (Brenda); S. Bahn (Sabine)

    2016-01-01

    textabstractFew serum biomarker tests are implemented in clinical practice and recent reports raise concerns about poor reproducibility of biomarker studies. Here, we investigated the potential role of sex and female hormonal status in this widespread irreproducibility. We examined 171 serum protein

  18. A Wireless Monitoring Sub-nA Resolution Test Platform for Nanostructure Sensors

    Directory of Open Access Journals (Sweden)

    Young Min Jhon

    2013-06-01

    Full Text Available We have constructed a wireless monitoring test platform with a sub-nA resolution signal amplification/processing circuit (SAPC and a wireless communication network to test the real-time remote monitoring of the signals from carbon nanotube (CNT sensors. The operation characteristics of the CNT sensors can also be measured by the ISD-VSD curve with the SAPC. The SAPC signals are transmitted to a personal computer by Bluetooth communication and the signals from the computer are transmitted to smart phones by Wi-Fi communication, in such a way that the signals from the sensors can be remotely monitored through a web browser. Successful remote monitoring of signals from a CNT sensor was achieved with the wireless monitoring test platform for detection of 0.15% methanol vapor with 0.5 nA resolution and 7 Hz sampling rate.

  19. Marital status, nation marital status composition, and self-assessed health: A multilevel test of four hypotheses in 29 European countries

    NARCIS (Netherlands)

    Huijts, T.H.M.; Kraaykamp, G.L.M.

    2011-01-01

    This study examines to what extent the often found association between marital status and self-assessed health is influenced by the marital composition of the country people live in. Four hypotheses explaining why the national marital status composition may be influential are derived and tested. Whe

  20. Monitoring and modeling water temperature and trophic status of a shallow Mediterranean lake

    Science.gov (United States)

    Giadrossich, Filippo; Bueche, Thomas; Pulina, Silvia; Marrosu, Roberto; Padedda, Bachisio Mario; Mariani, Maria Antonietta; Vetter, Mark; Cohen, Denis; Pirastru, Mario; Niedda, Marcello; Lugliè, Antonella

    2017-04-01

    Lakes are sensitive to changes in climate and human activities. Over the last few decades, Mediterranean lakes have experienced various problems due to the current climate change (drought, flood, warming, salt accumulation, water quality changes, etc.), often amplified by water use, intensification of land use activities, and pollution. The overall impact of these changes on water resources is still an open question. In this study we monitor the trophic status and the dynamics of water temperature of Lake Baratz, the only natural lake in Sardinia, Italy, characterized by high salinity and shallow depth. We extend the research carried out in the past 8 years by integrating new physical, chemical and biological data using a multidisciplinary approach that combines hydrological and biological dynamics. In particular, the lake water balance and the thermal and hydrochemical regime are studied with a lake dynamic model (the General Lake Model or GLM) which combine the energy budget method for estimating lake evaporation, and a physically-based rainfall-runoff simulator for estimating lake inflow, calibrated with measurements at the cross section of the main inlet stream. The trophic state of the lake was evaluated applying the OCDE Probability Distribution Diagrams method, which requires nutrient concentrations in the lake (total phosphorus), phytoplankton chlorophyll a and Secchi disk transparency data. We collected field data from a raft station and a land station, measuring net solar radiation, air temperature and relative humidity, precipitation, wind velocity, atmospheric pressure, and temperature from thermistors submerged in the uppermost three centimeters of water and beneath the lake surface at depths of 1, 2, 3, 4, 5, 6, and 8 m. Samples for nutrients and chlorophyll a analyses were collected at the same above mentioned depths close to the raft station using a Niskin bottle. Temperature, salinity, pH, and dissolved oxygen were measured using a multi

  1. The functional status of the professional football players during functional testing procedure

    Directory of Open Access Journals (Sweden)

    Pavlichenko P.P.

    2015-11-01

    Full Text Available The purpose of the investigation was the analysis of the functional status of professional football players during the special functional testing procedure (shuttle test. We used different testing methods such as an ergometry, gas analyzing, pulsemetry, and biochemical blood lactate level measuring for checking up physical conditioning. The technique “PHAZAGRAF” was used for assessment of the functional status of players by measuring the ІТ -index of symmetry of T-wave in standard ECG and for testing of vegetative system tonus. We used mathematic methods for data processing. The test of physical readiness showed 11 players with high level capacity to aerobic work with the result of more than 885 seconds. Low result was fixed when the player`s run-time was less than 820 seconds. The findings showed that functional status failures are attendant with ІТ -increasing and lowering of total aerobic readiness. This is revealed in lowering of the maximum oxygen consumption that showed lowering of total aerobic capacity. There was also found that increasing of the standard deviation of ІТ -index could accompany lowering of the running time in the shuttle test. Therewith, vegetative tonus failures in the form of prevailing of sympathetic system activity are not obligatory followed with failures of special or total capacity to work.

  2. Nationwide survey for current clinical status of amniocentesis and maternal serum marker test in Japan.

    Science.gov (United States)

    Miyake, Hidehiko; Yamada, Shigehito; Fujii, Yosuke; Sawai, Hideaki; Arimori, Naoko; Yamanouchi, Yasuko; Ozasa, Yuka; Kanai, Makoto; Sago, Haruhiko; Sekizawa, Akihiko; Takada, Fumio; Masuzaki, Hideaki; Matsubara, Yoichi; Hirahara, Fumiki; Kugu, Koji

    2016-10-01

    Prenatal testing has been provided in Japan over the past several decades. However, it is difficult to assess the clinical status of amniocentesis (AC) and maternal serum markers (MSM) because obstetricians can perform these tests without registration. This study aims to investigate the current clinical status of AC and MSM in Japan. We conducted a questionnaire study that was intended for a total of 5622 Japanese obstetrics/gynecology facilities during October 2013 to January 2014. The response rate was 40.8% (2295/5622). Of the 2295 facilities, 864 performed MSM (37.7%), 619 performed AC (27.0%) and 412 performed both (18.0%). The average number of MSM tests was 2.0 per month (range 0-52), and the average number of AC tests was 2.4 per month (range 0-30). Involvement of genetic professionals, such as clinical geneticists (CGs) and certified genetic counselors (CGCs), contribute to a content-rich explanation and management of difficult issues and lengthened the explanation time. Nevertheless, relatively few facilities employed these specialists (MSM: 96/864 and AC: 128/619). This is the first study to highlight the current clinical status of AC and MSM tests in Japan. Active involvement of CGs and CGCs can provide more appropriate genetic counseling for prenatal tests.

  3. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  4. Fast Flux Test Facility performance monitoring management information, October 1988

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1988-11-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. Overall performance indicators are listed in Table 1. The ``other`` performance indicators, listed in Table 2, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. Any concerns regarding the accuracy or analysis of the specific indicator should be addressed to the responsible manager identified on the figure. This report must be reviewed with the understanding that both the design and the mission are different for FFTF compared to commercial power reactors. 26 figs.

  5. Monitoring and data analysis for the Vadose Zone Monitoring System (VZMS), McClellan AFB. Quarterly status report

    Energy Technology Data Exchange (ETDEWEB)

    Zawislanski, P.T.; Salve, R.; Freifeld, B. [and others

    1997-05-28

    This report contains information on field and laboratory work performed between January and May 15th 1997 at site S-7 in IC 34, at McClellan AFB. At this location, a Vadose Zone Monitoring System (VZMS) is currently being used to collect subsurface data including hydraulic potential, soil gas pressure, moisture content, water chemistry, gas chemistry, and temperature. Due to delays in the completion of the above-ground installations, data collection did not commence until mid-February. As a result, the data presented in this report is preliminary.

  6. Artificial intelligence techniques for ground test monitoring of rocket engines

    Science.gov (United States)

    Ali, Moonis; Gupta, U. K.

    1990-01-01

    An expert system is being developed which can detect anomalies in Space Shuttle Main Engine (SSME) sensor data significantly earlier than the redline algorithm currently in use. The training of such an expert system focuses on two approaches which are based on low frequency and high frequency analyses of sensor data. Both approaches are being tested on data from SSME tests and their results compared with the findings of NASA and Rocketdyne experts. Prototype implementations have detected the presence of anomalies earlier than the redline algorithms that are in use currently. It therefore appears that these approaches have the potential of detecting anomalies early eneough to shut down the engine or take other corrective action before severe damage to the engine occurs.

  7. Monitoring of aquifer pump tests with Magnetic Resonance Sounding (MRS)

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, Esben; Bauer-Gottwein, Peter

    2009-01-01

    Magnetic Resonance Sounding (MRS) can provide valuable data to constrain and calibrate groundwater flow and transport models. With this non-invasive geophysical technique, field measurements of water content and hydraulic conductivities can be obtained. We developed a hydrogeophyiscal forward met...... to pump tests in which a partially penetrating pumping well is used, because the limited drawdown around the extraction well causes smaller changes in received signal compared to a fully penetrating well....... method, which calculates the MRS-signal generated by an aquifer pump test. A synthetic MRS-dataset was subsequently used to determine the hydrogeological parameters in an inverse parameter estimation approach. This was done for a pump test with a partially and fully penetrating well. With the MRS data we...... were able to retrieve the hydrogeological parameters of the aquifer. However, the differences in MRS signal in time, when the instrument is positioned on top of the extraction well, were small compared to the electromagnetic noise. This could especially limit the applicability of the MRS technique...

  8. The integrated Status and Effectiveness Monitoring Program : U.S. Forest Service Fish Abundance and Steelhead Redd Surveys Annual Report : January 1 - December 31, 2008.

    Energy Technology Data Exchange (ETDEWEB)

    Call, Justin

    2008-12-08

    This contract report is one of a series of reports that document implementation components of the Bonneville Power Administration's (BPA) funded project: Integrated Status and Effectiveness Monitoring Program (ISEMP - BPA project No.2003-017-00, Chris Jordan, NOAA-NWFSC project sponsor). Other components of the project are separately reported, as explained below. The ISEMP project has been created as a cost effective means of developing protocols and new technologies, novel indicators, sample designs, analytical data management, communication tools and skills, and restoration experiments that support the development of a region-wide Research, Monitoring, and Evaluation (RME) program to assess the status of anadromous salmonids populations, their tributary habitat and restoration and management actions. The most straightforward approach to developing a regional-scale monitoring and evaluation program would be to increase standardization among status and trend monitoring programs. However, the diversity of species and their habitat, as well as the overwhelming uncertainty surrounding indicators, metrics, and data interpretation methods requires the testing of multiple approaches. Thus, ISEMP has adopted an approach to develop a broad template that may differ in the details among subbasins, but one that will ultimately lead to the formation of a unified RME process for the management of anadromous salmonid populations and habitat across the Columbia River Basin. ISEMP has been initiated in three pilot areas, the Wenatchee/Entiat, John Day, and Salmon. To balance replicating experimental approaches with the goal of developing monitoring and evaluation tools that apply as broadly as possible across the Pacific Northwest, these subbasins were chosen as representative of a wide range of potential challenges and conditions, e.g., differing fish species composition and life histories, ecoregions, institutional settings, and existing data. ISEMP has constructed a

  9. Parameters monitoring and control for flueric actuators testing syste

    Directory of Open Access Journals (Sweden)

    Tiberiu Adrian SALAORU

    2014-04-01

    Full Text Available A wide range of air supply parameters is needed for the flueric actuators testing in order to find their optimum working regime. A system for conditioning these parameters, namely pressure, temperature, mass and volume flow rate has been built for this purpose. The measured values are continuously stored on the PC hard drive and are checked automatically for keeping them in the normal operating range. In case any of them are going out of this range, this system warns the operator and performs automatic actions for limiting or partially or totally shutting down the system.

  10. Fast Flux Test Facility performance monitoring management information, January 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D. J.

    1989-02-01

    The plant operated at full power for about half the month of January. Two test outages accounted for the remaining time, during which MOTA-1F, FSP-1, PO-4 and PO-5 were removed from the reactor. One automatic scram occurred while adjusting nuclear instruments at 15% power. Most performance indicators reflect excellent FFTF operation in spite of staff shortages and high workloads. No lost work day injuries occurred in January, and none have occurred for twelve straight months. Slight rises in maintenance backlog indicators reinforce the need for continued concentrated effort to keep backlogs within parameters that compare favorably with the best commercial nuclear plants.

  11. Long-term Monitoring Plan for the Central Nevada Test Area

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Ahmed E

    2004-01-01

    This report discusses the long-term monitoring strategy developed for the Central Nevada Test Area (CNTA), where the Faultless underground nuclear test was conducted. It includes a thorough literature review of monitoring well network design. A multi-staged approach for development of the long-term monitoring well network for CNTA is proposed, incorporating a number of issues, including uncertainty of the subsurface environment, cost, selection of well locations, etc. The first stage is to use hydrogeologic expertise combined with model simulations and probability based approaches to select the first set of monitoring wells. The second stage will be based on an optimum design methodology that uses a suitable statistical approach, combined with an optimization approach, to augment the initial set of wells and develop the final long-term monitoring network.

  12. 40 CFR 265 interim status indicator-evaluation ground-water monitoring plan for the 216-B-63 trench

    Energy Technology Data Exchange (ETDEWEB)

    Bjornstad, B.N.; Dudziak, S.

    1989-03-01

    This document outlines a ground-water monitoring plan for the 216-B-63 trench located in the northeast corner of the 200-East Area on the Hanford Site in southeastern Washington State. It has been determined that hazardous materials (corrosives) were disposed of to the trench during past operations. Installation of an interim-status ground-water monitoring system is required to determine whether hazardous chemicals are leaching to the ground water from beneath the trench. This document summarizes the existing data that are available from near the 216-B-63 trench and presents a plan to determine the extent of ground-water contamination, if any, derived from the trench. The plan calls for the installation of four new monitoring wells located near the west end of the trench. These wells will be used to monitor ground-water levels and water quality immediately adjacent to the trench. Two existing RCRA monitoring wells, which are located near the trench and hydraulically upgradient of it, will be used as background wells. 46 refs., 15 figs., 12 tabs.

  13. Monitoring System for Storm Readiness and Recovery of Test Facilities: Integrated System Health Management (ISHM) Approach

    Science.gov (United States)

    Figueroa, Fernando; Morris, Jon; Turowski, Mark; Franzl, Richard; Walker, Mark; Kapadia, Ravi; Venkatesh, Meera; Schmalzel, John

    2010-01-01

    Severe weather events are likely occurrences on the Mississippi Gulf Coast. It is important to rapidly diagnose and mitigate the effects of storms on Stennis Space Center's rocket engine test complex to avoid delays to critical test article programs, reduce costs, and maintain safety. An Integrated Systems Health Management (ISHM) approach and technologies are employed to integrate environmental (weather) monitoring, structural modeling, and the suite of available facility instrumentation to provide information for readiness before storms, rapid initial damage assessment to guide mitigation planning, and then support on-going assurance as repairs are effected and finally support recertification. The system is denominated Katrina Storm Monitoring System (KStorMS). Integrated Systems Health Management (ISHM) describes a comprehensive set of capabilities that provide insight into the behavior the health of a system. Knowing the status of a system allows decision makers to effectively plan and execute their mission. For example, early insight into component degradation and impending failures provides more time to develop work around strategies and more effectively plan for maintenance. Failures of system elements generally occur over time. Information extracted from sensor data, combined with system-wide knowledge bases and methods for information extraction and fusion, inference, and decision making, can be used to detect incipient failures. If failures do occur, it is critical to detect and isolate them, and suggest an appropriate course of action. ISHM enables determining the condition (health) of every element in a complex system-of-systems or SoS (detect anomalies, diagnose causes, predict future anomalies), and provide data, information, and knowledge (DIaK) to control systems for safe and effective operation. ISHM capability is achieved by using a wide range of technologies that enable anomaly detection, diagnostics, prognostics, and advise for control: (1

  14. Development and testing of a prototype tool for integrated assessment of chemical status in marine environments.

    Science.gov (United States)

    Andersen, Jesper H; Murray, Ciarán; Larsen, Martin M; Green, Norman; Høgåsen, Tore; Dahlgren, Elin; Garnaga-Budrė, Galina; Gustavson, Kim; Haarich, Michael; Kallenbach, Emilie M F; Mannio, Jaakko; Strand, Jakob; Korpinen, Samuli

    2016-02-01

    We report the development and application of a prototype tool for integrated assessment of chemical status in aquatic environments based on substance- and matrix-specific environmental assessment criteria (thresholds). The Chemical Status Assessment Tool (CHASE) integrates data on hazardous substances in water, sediments and biota as well as bio-effect indicators and is based on a substance- or bio-effect-specific calculation of a 'contamination ratio' being the ratio between an observed concentration and a threshold value. Values 1.0 indicate areas potentially 'affected'. These ratios are combined within matrices, i.e. for water, sediment and biota and for biological effects. The overall assessment used a 'one out, all out principle' with regard to each matrix. The CHASE tool was tested in the Baltic Sea and the North Sea in 376 assessment units. In the former, the chemical status was >1.0 in practically all areas indicating that all areas assessed were potentially affected. The North Sea included areas classified as unaffected or affected. The CHASE tool can in combination with temporal trend assessments of individual substances be advantageous for use in remedial action plans and, in particular, for the science-based evaluation of the status and for determining which specific substances are responsible for a status as potentially affected.

  15. Integrated Status and Effectiveness Monitoring Program - Entiat River Rotary Screw Traps, Snorkel Surveys, and Steelhead Redd Surveys, 2008-2009.

    Energy Technology Data Exchange (ETDEWEB)

    Nelle, R.D.; Desgroseillier, Tom; Cotter, Michael [U.S. Fish and Wildlife Service

    2009-04-14

    The USFWS Mid-Columbia River Fishery Resource Office (MCRFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program from March through November of 2008. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 16,782 wild salmonids were PIT tagged during the study period. Of this, 3,961(23.6%) were wild Oncorhynchus mykiss, 6,987 (41.6%) were wild spring run O. tshawytscha, and 5,591 (33.3%) were identified as wild O. tshawytscha of unknown run. Rotary screw trap efficiencies averaged 40.3% at the upper (Rkm 11.0) trap and 7.8% for the lower (Rkm 2.0) trap. These efficiencies were pooled for emigrant O. tshawytscha and O. mykiss. The MCRFRO conducted effectiveness monitoring snorkel surveys at 24 sites during the winter period and 30 sites during the summer and fall periods of 2008 as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. The 2008 steelhead spawning grounds surveys were conducted weekly in the main Entiat River from rkm 1.1 to 44.2. A total of 222 steelhead redds were identified over the period from February 28 to June 16 2008 with April being the peak spawning month. Approximately 80% of the steelhead redds were located downstream of the rkm 26.

  16. Integrated Status and Effectiveness Monitoring Program - Entiat River Rotary Screw Traps,Snorkel Surveys, and Steelhead Redd Surveys, 2008.

    Energy Technology Data Exchange (ETDEWEB)

    Nelle, R.D.; Desgroseiller, Tom; Cotter, Michael (U.S. Fish and Wildlife Service)

    2009-02-17

    The USFWS Mid-Columbia River Fishery Resource Office (MCRFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program from March through November of 2008. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 16,782 wild salmonids were PIT tagged during the study period. Of this, 3,961(23.6%) were wild Oncorhynchus mykiss, 6,987 (41.6%) were wild spring run O. tshawytscha, and 5,591 (33.3%) were identified as wild O. tshawytscha of unknown run. Rotary screw trap efficiencies averaged 40.3% at the upper (Rkm 11.0) trap and 7.8% for the lower (Rkm 2.0) trap. These efficiencies were pooled for emigrant O. tshawytscha and O. mykiss. The MCRFRO conducted effectiveness monitoring snorkel surveys at 24 sites during the winter period and 30 sites during the summer and fall periods of 2008 as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. The 2008 steelhead spawning grounds surveys were conducted weekly in the main Entiat River from rkm 1.1 to 44.2. A total of 222 steelhead redds were identified over the period from February 28 to June 16 2008 with April being the peak spawning month. Approximately 80% of the steelhead redds were located downstream of the rkm 26.

  17. Status of advanced airfoil tests in the Langley 0.3-meter transonic cryogenic tunnel

    Science.gov (United States)

    Ladson, C. L.; Ray, E. J.

    1984-01-01

    A joint NASA/U.S. industry program to test advanced technology airfoils in the Langley 0.3-meter Transonic Tunnel (TCT) was formulated under the Langley ACEE Project Office. The objectives include providing U.S. industry an opportunity to compare their most advanced airfoils to the latest NASA designs by means of high Reynolds number tests in the same facility. At the same time, industry would again experience in the design and construction of cryogenic test techniques. The status and details of the test program are presented. Typical aerodynamic results obtained, to date, are presented at chord Reynolds number up to 45 x 10(6) and are compared to results from other facilities and theory. Details of a joint agreement between NASA and the Deutsche Forschungs- und Versuchsantalt fur Luft- and Raumfahrt e.V. (DFVLR) for tests of two airfoils are also included. Results of these tests will be made available as soon as practical.

  18. Community monitoring for youth violence surveillance: testing a prediction model.

    Science.gov (United States)

    Henry, David B; Dymnicki, Allison; Kane, Candice; Quintana, Elena; Cartland, Jenifer; Bromann, Kimberly; Bhatia, Shaun; Wisnieski, Elise

    2014-08-01

    Predictive epidemiology is an embryonic field that involves developing informative signatures for disorder and tracking them using surveillance methods. Through such efforts assistance can be provided to the planning and implementation of preventive interventions. Believing that certain minor crimes indicative of gang activity are informative signatures for the emergence of serious youth violence in communities, in this study we aim to predict outbreaks of violence in neighborhoods from pre-existing levels and changes in reports of minor offenses. We develop a prediction equation that uses publicly available neighborhood-level data on disorderly conduct, vandalism, and weapons violations to predict neighborhoods likely to have increases in serious violent crime. Data for this study were taken from the Chicago Police Department ClearMap reporting system, which provided data on index and non-index crimes for each of the 844 Chicago census tracts. Data were available in three month segments for a single year (fall 2009, winter, spring, and summer 2010). Predicted change in aggravated battery and overall violent crime correlated significantly with actual change. The model was evaluated by comparing alternative models using randomly selected training and test samples, producing favorable results with reference to overfitting, seasonal variation, and spatial autocorrelation. A prediction equation based on winter and spring levels of the predictors had area under the curve ranging from .65 to .71 for aggravated battery, and .58 to .69 for overall violent crime. We discuss future development of such a model and its potential usefulness in violence prevention and community policing.

  19. Narrative psychological content analysis as a tool for psychological status monitoring of crews in isolated, confined and extreme settings

    Science.gov (United States)

    Ehmann, B.; Balázs, L.; Fülöp, É.; Hargitai, R.; Kabai, P.; Péley, B.; Pólya, T.; Vargha, A.; László, J.

    2011-05-01

    This paper is about a pilot application of narrative psychological content analysis in the psychological status monitoring of Crew 71 of a space analog simulation environment, the Mars Desert Research Station (MDRS). Both the method and its theoretical framework, Scientific Narrative Psychology, are original developments by Hungarian psychologists [5] (László, 2008). The software was NooJ, a multilingual linguistic development environment [11] (Silberztein, 2008). Three measures were conceptualized and assessed: emotional status, team spirit and subjective physical comfort. The results showed the patterns of these three measures on a daily basis at group level, and allowed for detecting individual differences as well. The method is adaptable to languages involved in space psychology, e.g. Russian, French and German in addition to English.

  20. Strengthening HIV Test Access and Treatment Uptake Study (Project STATUS): A Randomized Trial of HIV Testing and Counseling Interventions

    Science.gov (United States)

    McNaghten, A. D.; Mneimneh, Allison Schilsky; Farirai, Thato; Wamai, Nafuna; Ntiro, Marylad; Sabatier, Jennifer; Makhunga-Ramfolo, Nondumiso; Mwanasalli, Salli; Awor, Anna; Moore, Jan

    2016-01-01

    Objective To determine which of 3 HIV testing and counseling (HTC) models in outpatient departments (OPDs) increases HIV testing and entry of newly identified HIV-infected patients into care. Design Randomized trial of HTC interventions. Methods Thirty-six OPDs in South Africa, Tanzania, and Uganda were randomly assigned to 3 different HTC models: (A) health care providers referred eligible patients (aged 18–49, not tested in the past year, not known HIV positive) to on-site voluntary counseling and testing for HTC offered and provided by voluntary counseling and testing counselors after clinical consultation; (B) health care providers offered and provided HTC to eligible patients during clinical consultation; and (C) nurse or lay counselors offered and provided HTC to eligible patients before clinical consultation. Data were collected from October 2011 to September 2012. We describe testing eligibility and acceptance, HIV prevalence, and referral and entry into care. Chi-square analyses were conducted to examine differences by model. Results Of 79,910 patients, 45% were age eligible and 16,099 (45%) age eligibles were tested. Ten percent tested HIV positive. Significant differences were found in percent tested by model. The proportion of age eligible patients tested by Project STATUS was highest for model C (54.1%, 95% confidence interval [CI]: 42.4 to 65.9), followed by model A (41.7%, 95% CI: 30.7 to 52.8), and then model B (33.9%, 95% CI: 25.7 to 42.1). Of the 1596 newly identified HIV positive patients, 94% were referred to care (96.1% in model A, 94.7% in model B, and 94.9% in model C), and 58% entered on-site care (74.4% in model A, 54.8% in model B, and 55.6% in model C) with no significant differences in referrals or care entry by model. Conclusions Model C resulted in the highest proportion of all age-eligible patients receiving a test. Although 94% of STATUS patients with a positive test result were referred to care, only 58% entered care. We found no

  1. Review of present groundwater monitoring programs at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Hershey, R.L.; Gillespie, D.

    1993-09-01

    Groundwater monitoring at the Nevada Test Site (NTS) is conducted to detect the presence of radionuclides produced by underground nuclear testing and to verify the quality and safety of groundwater supplies as required by the State of Nevada and federal regulations, and by U.S. Department of Energy (DOE) Orders. Groundwater is monitored at water-supply wells and at other boreholes and wells not specifically designed or located for traditional groundwater monitoring objectives. Different groundwater monitoring programs at the NTS are conducted by several DOE Nevada Operations Office (DOE/NV) contractors. Presently, these individual groundwater monitoring programs have not been assessed or administered under a comprehensive planning approach. Redundancy exists among the programs in both the sampling locations and the constituents analyzed. Also, sampling for certain radionuclides is conducted more frequently than required. The purpose of this report is to review the existing NTS groundwater monitoring programs and make recommendations for modifying the programs so a coordinated, streamlined, and comprehensive monitoring effort may be achieved by DOE/NV. This review will be accomplished in several steps. These include: summarizing the present knowledge of the hydrogeology of the NTS and the potential radionuclide source areas for groundwater contamination; reviewing the existing groundwater monitoring programs at the NTS; examining the rationale for monitoring and the constituents analyzed; reviewing the analytical methods used to quantify tritium activity; discussing monitoring network design criteria; and synthesizing the information presented and making recommendations based on the synthesis. This scope of work was requested by the DOE/NV Hydrologic Resources Management Program (HRMP) and satisfies the 1993 (fiscal year) HRMP Groundwater Monitoring Program Review task.

  2. Present status of contamination monitoring at the Dalat Nuclear Research Institute (DNRI)

    Energy Technology Data Exchange (ETDEWEB)

    Hoang Van Nguyen [Dalat Nuclear Research Inst. (Viet Nam)

    1997-06-01

    The Dalat nuclear research reactor was renovated and upgraded from the previous TRIGA reactor. In Vietnam, it is a unique nuclear device having suitable neutron flux for the radioisotope production and neutron activation analysis. Soon after the reactor reached its initial criticality in November 1983, a programme has been formed to develop the application of nuclear techniques in various fields. In addition, the use of radioisotopes for diagnostic, therapeutic and other research purposes has been in progress. In order to support these activities, the radiation protection, especially the radiation contamination monitoring has been properly paid attention to. In DNRI, the Radiation Protection Department is responsible for controlling and supervising radiation and working safety for all activities. In this paper, the following items are described on radiation contamination monitoring: controlled area, surface contamination monitoring, and airborne concentration monitoring. (G.K.)

  3. Application of structural health monitoring technologies to bio-systems: current status and path forward

    Science.gov (United States)

    Bhalla, Suresh; Srivastava, Shashank; Suresh, Rupali; Moharana, Sumedha; Kaur, Naveet; Gupta, Ashok

    2015-03-01

    This paper presents a case for extension of structural health monitoring (SHM) technologies to offer solutions for biomedical problems. SHM research has made remarkable progress during the last two/ three decades. These technologies are now being extended for possible applications in the bio-medical field. Especially, smart materials, such as piezoelectric ceramic (PZT) patches and fibre-Bragg grating (FBG) sensors, offer a new set of possibilities to the bio-medical community to augment their conventional set of sensors, tools and equipment. The paper presents some of the recent extensions of SHM, such as condition monitoring of bones, monitoring of dental implant post surgery and foot pressure measurement. Latest developments, such as non-bonded configuration of PZT patches for monitoring bones and possible applications in osteoporosis detection, are also discussed. In essence, there is a whole new gamut of new possibilities for SHM technologies making their foray into the bi-medical sector.

  4. Comparison of Wired and Wireless Bio-Electrical Impedance Fluid Status Monitoring Devices and Validation to Body Mass and Urine Specific Gravity Changes Following Mild Dehydration

    Science.gov (United States)

    2008-01-18

    status assessment method, ZOE2, is FDA approved for fluid status monitoring. The ZOE2 measures thoracic bio -electrical impedance. A new wireless version...impedance as a valid measure of hydration status in clinical or controlled settings. However, there is speculation as to the utility of bio -electrical...no significant differences were detected between pre- to post-practice for the ZOE2 or ZOEW device. Bio -electrical impedance, as measured by the ZOEW

  5. The SUCIMA project: A status report on high granularity dosimetry and proton beam monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Caccia, M. [Dipartimento di Scienze CC.FF.MM., Universita dell' Insubria, Como (Italy)]. E-mail: Massimo.Caccia@uninsubria.it; Badano, L. [Fondazione per Adroterapia Oncologica, Novara (Italy); Berst, D. [Laboratoire d' Electronique et de Physique des Systemes Instrumentaux, Universite Luis Pasteur, Strasbourg (France); Centre National de la Recherce Scientifique/IN2P3 - Paris (France)] (and others)

    2006-05-01

    The SUCIMA collaboration has been developing instruments and methods for real-time, high granularity imaging of extended electron sources. In particular, dosimetry of intravascular brachytherapy {beta} sources has been intensively studied, together with monitoring of hadrontherapy beams by imaging of secondary electrons emitted by a non-disruptive target. The paper reports the latest results on absolute dosimetry with a large-area silicon strip detectors and on beam monitoring with a hybrid pad sensor.

  6. TRUEX Radiolysis Testing Using the INL Radiolysis Test Loop: FY-2012 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Dean R. Peterman; Lonnie G. Olson; Richard D. Tillotson; Rocklan G. McDowell; Jack D. Law

    2012-09-01

    The INL radiolysis test loop has been used to evaluate the affect of radiolytic degradation upon the efficacy of the strip section of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. The nominal composition of the TRUEX solvent used in this study is 0.2 M CMPO and 1.4 M TBP dissolved in n-dodecane and the nominal composition of the TRUEX strip solution is 1.5 M lactic acid and 0.050 M diethylenetriaminepentaacetic acid. Gamma irradiation of a mixture of TRUEX process solvent and stripping solution in the test loop does not adversely impact flowsheet performance as measured by stripping americium ratios. The observed increase in americium stripping distribution ratios with increasing absorbed dose indicates the radiolytic production of organic soluble degradation compounds.

  7. Cascade testing for carrier status in cystic fibrosis in a large family.

    Science.gov (United States)

    Turner, G; Meagher, W; Willis, C; Colley, P

    1993-08-02

    The offer to determine carrier status for cystic fibrosis (CF) was made to the 230 descendants of a couple who were presumed to carry the delta F508 mutation. "Cascade testing" was employed, in which the mutation is followed from the oldest generation down. Compliance was over 75% and family members were relieved of the anxiety engendered by uncertainty. In one couple considering having a family, both partners were found to be carriers.

  8. Compact mobile-reader system for two-way wireless communication, tracking and status monitoring for transport safety and security

    Science.gov (United States)

    Tsai, Han-Chung; Liu, Yung Y.; Lee, Hok L.; Craig, Brian; Byrne, Kevin; Mittal, Ketan; Scherer, Justin C.

    2016-12-06

    A system for monitoring a plurality radio frequency identification tags is described. The system uses at least one set of radio frequency identification tags. Each tag is attached to a container and includes several sensors for detecting physical conditions of said container. The system includes at least one autonomous intermediate reader in wireless communication with the frequency identification tags. The intermediate reader includes external wireless communication system, intermediate reader logic controller, and a self-contained rechargeable power supply. The system uses a central status reporting system in communication the intermediate reader.

  9. [Monitoring of environmental pollution in Armenia and certain issues on reproductive health and cytogenetic status of organism].

    Science.gov (United States)

    Tadevosian, N S; Muradian, S A; Tadevosian, A E; Khachatrian, B G; Dzhandzhapanian, A N; Parsadanian, G G; Pogosian, S B; Gevorkian, N B; Guloian, A A

    2012-01-01

    Investigations aimed at the study on the state of environment from the point of pollution by organochlorine pesticides and their metabolites (HCH, DDT, DDE and DDD), as well as on possible unfavorable impact due to carriage of mentioned persistent organic pollutants (POPs) towards reproductive health and cytogenetic status of organism were done. In parallel, monitoring of possible mutagenic components of the environment was also conducted. As to obtained data, residues of organochlorine pesticides are continually determined with high frequency both in environmental media, agricultural foodstuffs and biomedia of rural population of observed region (Aragatsotn marz, Armenia). No changes in mutagenic background were registered. The represented results of the study make fragment of complex social-hygienic, monitoring investigations on environmental quality that would further serve as a platform for working out the recommendations on reduction of environmental pollution and improvement of health protection issues in Armenia.

  10. Status and plans for a SRF accelerator test faciliy at Fermilab

    CERN Document Server

    Leibfritz, J; Carlson, K; Chase, B; Church, M; Harms, E; Klebaner, A; Kucera, M; Lackey, S; Martinez, A; Nagaitsev, S; Nobrega, L; Piot, P; Reid, J; Wendt, M; Wesseln, S

    2012-01-01

    A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. Expansion plans of the facility are underway that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. In addition to testing accelerator components, this facility will be used to test RF power equipment, instrumentation, LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  11. Standard-B auto grab sampler hydrogen monitoring system, Acceptance Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Lott, D.T.

    1995-05-18

    Project W-369, Watch List Tank Hydrogen Monitors, installed a Standard-C Hydrogen Monitoring System (SHMS) on the Flammable gas waste tank AN-104. General Support Projects (8K510) was support by Test Engineering (7CH30) in the performance of the Acceptance Test Procedures (ATP) to qualify the SHMS cabinets on the waste tank. The ATP`s performance was controlled by Tank Farm work package. This completed ATP is transmitted by EDT-601748 as an Acceptance Test Report (ATR) in accordance with WHC-6-1, EP 4.2 and EP 1.12.

  12. Wind Turbine Drivetrain Condition Monitoring During GRC Phase 1 and Phase 2 Testing

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, S.; Link, H.; LaCava, W.; van Dam, J.; McNiff, B.; Veers, P.; Keller, J.; Butterfield, S.; Oyague, F.

    2011-10-01

    This report will present the wind turbine drivetrain condition monitoring (CM) research conducted under the phase 1 and phase 2 Gearbox Reliability Collaborative (GRC) tests. The rationale and approach for this drivetrain CM research, investigated CM systems, test configuration and results, and a discussion on challenges in wind turbine drivetrain CM and future research and development areas, will be presented.

  13. Testing and Monitoring E-Business using the Event-driven Test Scripting Language

    Energy Technology Data Exchange (ETDEWEB)

    Durand, Jacques [Fujitsu Software; Kulvatunyou, Boonserm [ORNL; Woo, Jungyub [Pohang University of Science and Technology (POSTECH), Korea; Monica, Martin [Sun Microsystems, Inc.

    2007-01-01

    This paper addresses challenges associated with conformance and interoperability testing of today's e-business technologies and proposes a new approach that improves on existing test scripting languages and operation modes. A test model and scripting are described, namely, the Event-driven Test Scripting Language (eTSL). We contrasted this new approach with existing testing technologies and provide examples that illustrate the use of both the model and the language.

  14. Status of MICROSCOPE, a mission to test the Equivalence Principle in space

    CERN Document Server

    Bergé, Joel; Rodrigues, Manuel

    2015-01-01

    MICROSCOPE is a French Space Agency mission that aims to test the Weak Equivalence Principle in space down to an accuracy of $10^{-15}$. This is two orders of magnitude better than the current constraints, which will allow us to test General Relativity as well as theories beyond General Relativity which predict a possible Weak Equivalence Principle violation below $10^{-13}$. In this communication, we describe the MICROSCOPE mission, its measurement principle and instrument, and we give an update on its status. After a successful instrument's commissioning, MICROSCOPE is on track for on-schedule launch, expected in 2016.

  15. Monitoring of small heat pumps using standardised tests in 2009; Monitoring von Klein-Waermepumpen mittels Normpruefungen 2009 - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Eschmann, M.

    2010-02-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the monitoring in 2009 of small heat pumps with heating powers up to 100 kW using standardised tests. The authors note that, in 2009, more heat pump tests were carried out than in the years before as a result of improved facilities and procedures. Also, after initial improvement in previous years, Coefficient of Performance (COP) values have deteriorated. This is, according to the authors, due to lower prices on the market. This means that heat pumps are built cost-optimised and are not developed to reach the maximum energetic efficiency. The tests carried out are listed and the results obtained are presented in graphical form and commented on. The EHPA/DACH quality label and the required COP values are reviewed.

  16. A SysML Test Model and Test Suite for the ETCS Ceiling Speed Monitor

    DEFF Research Database (Denmark)

    Braunstein, Cécile; Peleska, Jan; Schulze, Uwe

    2014-01-01

    In this technical report a detailed model description of a train control system application is given. The application consists of the ceiling speed monitoring (CSM) function for the European Vital Computer which is the main onboard controller for trains conforming to the European Train Control Sy...

  17. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    KINKEL, C.C.

    1999-12-14

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected to the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).

  18. 105KE Basin Area Radiation Monitor System (ARMS) Acceptance Test Procedure

    CERN Document Server

    Kinkel, C C

    1999-01-01

    This procedure is intended for the Area Radiation Monitoring System, ARMS, that is replacing the existing Programmable Input-Output Processing System, PIOPS, radiation monitoring system in the 105KE basin. The new system will be referred to as the 105KE ARMS, 105KE Area Radiation Monitoring System. This ATP will ensure calibration integrity of the 105KE radiation detector loops. Also, this ATP will test and document the display, printing, alarm output, alarm acknowledgement, upscale check, and security functions. This ATP test is to be performed after completion of the 105KE ARMS installation. The alarm outputs of the 105KE ARMS will be connected to the basin detector alarms, basin annunciator system, and security Alarm Monitoring System, AMS, located in the 200 area Central Alarm Station (CAS).

  19. Monitoring nutritional status accurately and reliably in adolescents with anorexia nervosa.

    Science.gov (United States)

    Martin, Andrew C; Pascoe, Elaine M; Forbes, David A

    2009-01-01

    Accurate assessment of nutritional status is a vital aspect of caring for individuals with anorexia nervosa (AN) and body mass index (BMI) is considered an appropriate and easy to use tool. Because of the intense fear of weight gain, some individuals may attempt to mislead the physician. Mid-upper arm circumference (MUAC) is a simple, objective method of assessing nutritional status. The setting is an eating disorders clinic in a tertiary paediatric hospital in Western Australia. The aim of this study is to evaluate how well MUAC correlates with BMI in adolescents with AN. Prospective observational study to evaluate nutritional status in adolescents with AN. Fifty-five adolescents aged 12-17 years with AN were assessed between January 1, 2004 and January 1, 2006. MUAC was highly correlated with BMI (r = 0.79, P or=20 cm rarely required hospitalisation (negative predictive value 93%). MUAC reflects nutritional status as defined by BMI in adolescents with AN. Lack of consistency between longitudinal measurements of BMI and MUAC should be viewed suspiciously and prompt a more detailed nutritional assessment.

  20. A systematic review on heart-rate recovery to monitor changes in training status in athletes

    NARCIS (Netherlands)

    Daanen, H.A.M.; Lamberts, R.P.; Kallen, V.L.; Jin, A.; Meeteren, N.L.U.

    2012-01-01

    Heart-rate recovery (HRR) has been proposed as a marker of autonomic function and training status in athletes. The authors performed a systematic review of studies that examined HRR after training. Five cross-sectional studies and 8 studies investigating changes over time (longitudinal) met our

  1. A systematic review on heart-rate recovery to monitor changes in training status in athletes

    NARCIS (Netherlands)

    Daanen, H.A.M.; Lamberts, R.P.; Kallen, V.L.; Jin, A.; Van Meeteren, N.L.U.

    2012-01-01

    Heart-rate recovery (HRR) has been proposed as a marker of autonomic function and training status in athletes. The authors performed a systematic review of studies that examined HRR after training. Five cross-sectional studies and 8 studies investigating changes over time (longitudinal) met our crit

  2. A low-cost microcontroller-based system to monitor crop temperature and water status

    Science.gov (United States)

    A prototype microcontroller-based system was developed to automate the measurement and recording of soil-moisture status and canopy-, air-, and soil-temperature levels in cropped fields. Measurements of these conditions within the cropping system are often used to assess plant stress, and can assis...

  3. Understanding controls on biotic assemblages and ecological status in Zambian rivers for the development of sustainable monitoring protocols

    Science.gov (United States)

    Kennedy, Michael; Gibbins, Chris; Lowe, Steven; Dallas, Helen; Taylor, Jonathan; Lang, Pauline; Saili, Kothelani; Sichingabula, Henry; Murphy, Kevin

    2014-05-01

    The water resources of Zambia are likely to experience increasing multiple pressures in the future as a result of very high predicted population growth, industrial development, land use change, and potentially, altered regional rainfall patterns. It is well known that rivers in tropical regions typically have a rich biodiversity, controlled in part by inter-annual variability in climate and discharge, and in part by local catchment conditions. However, till recently little country-wide work had had been carried out on the biota of Zambian rivers, and little was therefore known about the ecological status, or degree of catchment alteration of many of the rivers. To underpin sustainable water management, protocols have been developed to assess the ecological status of Zambian rivers. This paper describes the development of the protocols and their application to provide the first extensive assessment of the ecological status of rivers in the country. The protocols were designed to be simple, and hence rapid, easy and relatively inexpensive to apply. Status scores were derived for individual sites using sensitivity weightings from 3 major groups (macrophytes, diatoms and macroinvertebrates). The general approach was based on schemes used successfully elsewhere, with species and family sensitivity weightings modified so as be appropriate to Zambia. Modifications were based on a survey of 140 Zambian rivers, incorporating data on species distributions, physical habitat conditions and water quality. Analysis of historical data suggests that established Freshwater Ecoregions reflect hydro-climatic variability across Zambia. Survey data indicate that most of the spatial variation in biological assemblages across the country reflects these same hydro-climatic gradients, in addition to hydrochemical differences linked to geology. Site status scores suggest that rivers are generally in good health, although exceptions occur in some large urban areas and a small number of

  4. Deep Vadose Zone Treatability Test for the Hanford Central Plateau. Interim Post-Desiccation Monitoring Results, Fiscal Year 2015

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Strickland, Christopher E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Oostrom, Martinus [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Christian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tartakovsky, Guzel D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Timothy C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Ray E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chronister, Glen B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    A field test of desiccation is being conducted as an element of the Deep Vadose Zone Treatability Test Program. The active desiccation portion of the test has been completed. Monitoring data have been collected at the field test site during the post-desiccation period and are reported herein. This is an interim data summary report that includes about 4 years of post-desiccation monitoring data. The DOE field test plan proscribes a total of 5 years of post-desiccation monitoring.

  5. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Science.gov (United States)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-09-01

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS's) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS's. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS).

  6. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kheliewi, Abdullah S. [National Center for Radiation Protection, King Abdulaziz City for Science and Technology, 11442 Riyadh (Saudi Arabia); Holzheimer, Clous [ENVINET GmbH, Environmental Radiation Detection, Hans-Pinsel-Straße 4, 85540 Haar (Munich) (Germany)

    2014-09-30

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  7. Optimizing urine drug testing for monitoring medication compliance in pain management.

    Science.gov (United States)

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were testing from our panel. We also lowered the screening cutoff for cocaine to meet the clinical needs of the pain management center. In addition, we changed our testing algorithm for 6-acetylmorphine, benzodiazepines, and methadone. For example, due the high rate of false negative results using our immunoassay-based benzodiazepine screen, we removed the screening portion of the algorithm and now perform benzodiazepine confirmation up front in all specimens by liquid chromatography-tandem mass spectrometry. Conducting an interdisciplinary quality improvement project allowed us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  8. Acoustic emission monitoring of hot functional testing: Watts Bar Unit 1 Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, P.H.; Dawson, J.F.; Friesel, M.A.; Harris, J.C.; Pappas, R.A.

    1984-06-01

    Acoustic emission (AE) monitoring of selected pressure boundary areas at TVA's Watts Bar, Unit 1 Nuclear Power Plant during hot functional preservice testing is described in this report. The report deals with background, methodology, and results. The work discussed here is a major milestone in a program supported by NRC to develop and demonstrate application of AE monitoring for continuous surveillance of reactor pressure boundaries to detect and evaluate growing flaws. The subject work demonstrated that anticipated problem areas can be overcome. Work is continuing toward AE monitoring during reactor operation.

  9. In vitro tests for teratogens: desirable endpoints, test batteries and current status of the micromass teratogen test.

    Science.gov (United States)

    Flint, O P

    1993-01-01

    Information from in vitro tests can be usefully used as a component of the risk/hazard assessment process. In vivo studies will be required to confirm the in vitro data. If the in vitro test system is designed around endpoints that reflect changes following in vivo toxic insult then it may be possible to modify the in vitro system to account for some of the discrepancies observed between in vivo and in vitro outcomes. When the discrepancy can be accounted for by low bioavailability in vivo, pharmacokinetic studies may be required to determine the relevance of the in vitro toxic concentrations. Reproductive hazard, especially teratogenicity, has been the subject of intensive in vitro test development. The observation of teratogenicity may affect the development of new products more significantly than any other type or category of reproductive toxicity. The micromass test, involving culture of differentiating rat embryo limb and midbrain cells exposed to test agents, may be useful as part of a battery of in vitro tests for teratogens. The most recent protocol for the micromass test is described, followed by a summary of validation and mechanistic studies confirming its usefulness. The test is robust in its transfer to new laboratories. Interlaboratory variability is small.

  10. The Status of Energy Monitoring in Science and Industry by the Example of Material Handling Processes

    Directory of Open Access Journals (Sweden)

    Patrick Fekete

    2014-06-01

    Full Text Available Global mega trends attract increased resource preservation as well as system efficiency and arouse growing scientific, industrial and public attention, whereas process and technologic developments still lack realisation due to inaccurate knowledge of real process energy demand, associated possible savings and a low inducement for investment. This investigation develops a generally applicable process for energy data collection focussing on material handling systems based on a predefined target model for energy monitoring in order to generate a valid reference model. The introduction of Standardised Energy Consuming Activities (SECA model enables the development of energy based process functions as reference for its implementation to energetic investigations in various industrial applications. Analysing current and target state of energy monitoring in scientific and industrial investigations for logistics shows the developmental deficit of standardisation and realisation in energy monitoring.

  11. On0Line Fuel Failure Monitor for Fuel Testing and Monitoring of Gas Cooled Very High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ayman I. Hawari; Mohamed A. Bourham

    2010-04-22

    IVery High Temperature Reactors (VHTR) utilize the TRISO microsphere as the fundamental fuel unit in the core. The TRISO microsphere (~ 1- mm diameter) is composed of a UO2 kernel surrounded by a porous pyrolytic graphite buffer, an inner pyrolytic graphite layer, a silicon carbide (SiC) coating, and an outer pyrolytic graphite layer. The U-235 enrichment of the fuel is expected to range from 4% – 10% (higher enrichments are also being considered). The layer/coating system that surrounds the UO2 kernel acts as the containment and main barrier against the environmental release of radioactivity. To understand better the behavior of this fuel under in-core conditions (e.g., high temperature, intense fast neutron flux, etc.), the US Department of Energy (DOE) is launching a fuel testing program that will take place at the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL). During this project North Carolina State University (NCSU) researchers will collaborate with INL staff for establishing an optimized system for fuel monitoring for the ATR tests. In addition, it is expected that the developed system and methods will be of general use for fuel failure monitoring in gas cooled VHTRs.

  12. Intimate partner violence, consenting to HIV testing and HIV status among Zambian women.

    Science.gov (United States)

    Nelson, Kara A; Ferrance, Jacquelyn L; Masho, Saba W

    2016-09-01

    Sub-Saharan African countries are heavily burdened with HIV, which disproportionately affects women of reproductive age. Extant literature is inconsistent regarding the link between intimate partner violence and HIV. Data from the 2007 Zambian Demographic Health Survey of women aged 15-49 (n = 5014) were analysed. The influence of abuse by a current or former husband on consent to HIV testing and HIV positivity were evaluated. The unadjusted analysis showed a statistically significant association between intimate partner violence and consent to testing for HIV. Stratified analysis showed that there was a statistically significant association between intimate partner violence and HIV testing in rural areas but not in urban areas. However, the association lost its significance when adjusted for confounding factors. No statistically significant association was found between intimate partner violence and HIV-positive status. It is encouraging that women who experienced intimate partner were testing for HIV. Prevention efforts should continue addressing the needs of this population.

  13. Status of Testing and Characterization of CMS Alloy 617 and Alloy 230

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Weiju [ORNL; Santella, Michael L [ORNL; Battiste, Rick [ORNL; Terry, Totemeier [Idaho National Laboratory (INL); Denis, Clark [Idaho National Laboratory (INL)

    2006-08-01

    Status and progress in testing and characterizing CMS Alloy 617 and Alloy 230 tasks in FY06 at ORNL and INL are described. ORNL research has focused on CMS Alloy 617 development and creep and tensile properties of both alloys. In addition to refurbishing facilities to conduct tests, a significant amount of creep and tensile data on Alloy 230, worth several years of research funds and time, has been located and collected from private enterprise. INL research has focused on the creep-fatigue behavior of standard chemistry Alloy 617 base metal and fusion weldments. Creep-fatigue tests have been performed in air, vacuum, and purified Ar environments at 800 and 1000 C. Initial characterization and high-temperature joining work has also been performed on Alloy 230 and CCA Alloy 617 in preparation for creep-fatigue testing.

  14. Present status and future perspectives of research and test reactor in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Yoshihiko [Atomic Energy Research Laboratory, Musashi Institute of Technology, Kawasaki, Kanagawa (Japan); Kaieda, Keisuke [Department of Research Reactor, Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    2000-10-01

    Since 1957, Japan Atomic Energy Research Institute (JAERI) has constructed several research and test reactors to fulfill a major role in the study of nuclear energy and fundamental research. At present four reactors, the Japan Research Reactor No. 3 and No. 4 (JRR-3M and JRR-4 respectively), the Japan Materials Testing Reactor (JMTR) and the Nuclear Safety Research Reactor (NSRR) are in operation, and a new High Temperature Engineering Test Reactor (HTTR) has recently reached first criticality and now in the power up test. In 1966, the Kyoto University built the Kyoto University Reactor (KUR) and started its operation for joint use program of the Japanese universities. This paper introduces these reactors and describes their present operational status and also efforts for aging management. The recent tendency of utilization and future perspectives is also reported. (author)

  15. Moscow State University near-Earth radiation monitoring satellite system: current status and development

    Science.gov (United States)

    Panasyuk, Mikhail

    2016-07-01

    Radiation measurements using instruments have been designed and manufacturing in the Skobeltsyn Institute of Nuclear Physics of Lomonosov Moscow State University and installed onboard different satellites,i.e. LEO -"Meteor", ISS, GPS - GLONASS, GEO - "Electro" are presented as a basis of radiation monitoring system for control of radiation condition with a goal for to decrease radiation risk of spacecraft's damage on different orbits. Development of this system including radiation measurements onboard "Lomonosov"(LEO) satellite will be presented as well together with future project of multispacecraft LEO system for radiation monitoring.

  16. Using Non-Destructive Test Methods to Monitor Flaw Behavior in a Real· Time Test Environment

    Science.gov (United States)

    Springer, K. Q.; Kersker, K.; Miller, K.; Teles, S.

    2017-01-01

    Accurate modeling of flaw behavior in both propellant-liner-insulation and insulation-to-insulation interfaces is required for flight certification of NASA's Space Launch System solid rocket booster. In-situ monitoring of the flaw propagation using nondestructive test methods such as X-ray and ultrasonic testing allows pressure and volumetric flow data to be correlated with the time of flaw propagation during pressurization. The use of X-ray and ultrasonic test inspection allowed physical flaw growth to be tracked continuously throughout testing, overcoming a limitation in previous model validation techniques. The techniques used are capable of corroborating model predictions as well as validating simpler test methodologies for past and future testing efforts.

  17. Online fault diagnostics and testing of area gamma radiation monitor using wireless network

    Science.gov (United States)

    Reddy, Padi Srinivas; Kumar, R. Amudhu Ramesh; Mathews, M. Geo; Amarendra, G.

    2017-07-01

    Periodical surveillance, checking, testing, and calibration of the installed Area Gamma Radiation Monitors (AGRM) in the nuclear plants are mandatory. The functionality of AGRM counting electronics and Geiger-Muller (GM) tube is to be monitored periodically. The present paper describes the development of online electronic calibration and testing of the GM tube from the control room. Two electronic circuits were developed, one for AGRM electronic test and another for AGRM detector test. A dedicated radiation data acquisition system was developed using an open platform communication server and data acquisition software. The Modbus RTU protocol on ZigBee based wireless communication was used for online monitoring and testing. The AGRM electronic test helps to carry out the three-point electronic calibration and verification of accuracy. The AGRM detector test is used to verify the GM threshold voltage and the plateau slope of the GM tube in-situ. The real-time trend graphs generated during these tests clearly identified the state of health of AGRM electronics and GM tube on go/no-go basis. This method reduces the radiation exposures received by the maintenance crew and facilitates quick testing with minimum downtime of the instrument.

  18. First Operating Experiences of Beam Position Monitors in the TESLA Test Facility Linac

    Science.gov (United States)

    Lorenz, R.; Sachwitz, M.; Schreiber, H. J.; Tonisch, F.; Castellano, M.; Patteri, P.; Tazzioli, F.; Catani, L.

    1997-05-01

    Different types of monitors where installed in the TESLA Test Facility Linac to measure the beam position. At each superconducting quadrupole, the transverse beam position will be measured with a resolution of better than 10 μm, using a cylindrical cavity excited in the TM_110-mode by an off-center beam. In addition, two 'warm' cavities working at room temperature were built for the Injector I and the Bunch Compressor. The amplitude of the TM_110-mode and its phase are measured in a homodyne receiver. For the experimental area, stripline monitors having a resolution of better than 100 μm were built, tested and installed. The averaged position of the whole bunch train of Injector I is measured in a narrowband receiver using the amplitude-to-phase conversion. This paper summarizes the designs, cold tests and first operating experiences of both monitor types.

  19. THE TASK OF CONTINUING AIRWORTHINESS ON THE BASIS OF MONITORING RESOURCE STATUS

    Directory of Open Access Journals (Sweden)

    Yuriy M. Chinyuchin

    2017-01-01

    Full Text Available This article is devoted to basic statements according to scientific researches carried out in the area of airworthiness maintenance and aimed at creation of monitoring system of the aircraft equipment resource condition for the purpose of its resource and service life parameters control.The term monitoring is used here as consecutive process of obtaining, processing and analyzing the information on resources and aircraft equipment service life (planes, helicopters, aircraft engines and their accessories with the further use of this information for the problems solution of its own air fleet structure management, its updating and forecasting indica- tors of its operation processes efficiency.The most important and complex components of monitoring system and aircraft equipment resource condition, in particular are noted: the personified approach to the definition of aircraft equipment rational resources and service life; models of forecasting and aircraft resources processing management; decision-making models on increase of long life air- craft parameters taking into account maintenance cost; justification of expediency of aeronautical products retrofit by way of increasing their resource characteristics; definition methods of resource products necessary quantity by using of statisti- cal model; assessment methods of aviation components authenticity value; models of technical and economic efficiency of works on increase in individual resources of removable parts.Certain components of monitoring system are considered in more detail with the references indication.

  20. Current status and opportunities for therapeutic drug monitoring in the treatment of tuberculosis

    NARCIS (Netherlands)

    Zuur, Marlanka A.; Bolhuis, Mathieu S.; Anthony, Richard; den Hertog, Alice; van der Laan, Tridia; Wilffert, Bob; Lange, de Wiel; van Soolingen, Dick; Alffenaar, Jan-Willem C.

    Introduction: Tuberculosis remains a global health problem and pharmacokinetic variability has been postulated as one of the causes of treatment failure and acquired drug resistance. New developments enable implementation of therapeutic drug monitoring, a strategy to evaluate drug exposure in order

  1. Infauna monitoring Horns Rev offshore wind farm. Annual status report 2003

    Energy Technology Data Exchange (ETDEWEB)

    Bech, M.; Leonhars, S.B.; Pedersen, John

    2004-05-15

    ELSAM and ELTRA have established an offshore wind farm with an output of 160 MW in the waters of Horns Rev 1420 km off Blaevands Huk, which is the most westerly point of Denmark. The first phase of construction of the wind farm started in spring 2002. Before the construction activities took place, a baseline description of the benthos was conducted as a part of an environmental monitoring programme for the establishment of the Horns Rev Offshore Wind Farm. The baseline surveys for the present monitoring programme were conducted in the wind farm area on three occasions: spring 1999, spring 2001 and September 2001. In designated reference areas, surveys were conducted in spring 1999 and September 2001. The reference areas in 1999 and September 2001 were placed at two different geographical locations because the survey in September 2001 was planned to be a part of a fish monitoring programme. A comparison between the baseline study in spring 2001 and the baseline study in autumn 2001 clearly revealed that the biomass of most species increased considerably from spring to September. Despite the increase in biomass, the overall distribution of the species and their relative abundance did not change. In order to use the baseline data to investigate a possible impact after the construction of the wind farm, it was essential to arrange the monitoring programme either in spring or in September 2003, because the baseline studies were conducted in these periods. The monitoring programme was conducted in September 2003 after the wind farm had become operational, parallel with the survey on hard bottom substrates. The impacts of the wind farm on the benthic fauna (infauna) in the area were mainly expected to be due to the alteration of the local currents. As the changes in the currents are only minor, impacts on the water chemistry and on the benthic fauna resulting from hydrodynamic causes were expected to be limited or non-existent. The main objective of the present monitoring

  2. Moisture Monitoring at Area G, Technical Area 54, Los Alamos National Laboratory, 2016 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Levitt, Daniel Glenn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jennings, Terry L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-17

    Hydrological characterization and moisture monitoring activities provide data required for evaluating the transport of subsurface contaminants in the unsaturated and saturated zones beneath Area G, and for the Area G Performance Assessment and Composite Analysis. These activities have been ongoing at Area G, Technical Area 54 of the Los Alamos National Laboratory since waste disposal operations began in 1957. This report summarizes the hydrological characterization and moisture monitoring activities conducted at Area G. It includes moisture monitoring data collected from 1986 through 2016 from numerous boreholes and access tubes with neutron moisture meters, as well as data collected by automated dataloggers for water content measurement sensors installed in a waste disposal pit cover, and buried beneath the floor of a waste disposal pit. This report is an update of a nearly identical report by Levitt et al., (2015) that summarized data collected through early 2015; this report includes additional moisture monitoring data collected at Pit 31 and the Pit 38 extension through December, 2016. It also includes information from the Jennings and French (2009) moisture monitoring report and includes all data from Jennings and French (2009) and the Draft 2010 Addendum moisture monitoring report (Jennings and French, 2010). For the 2015 version of this report, all neutron logging data, including neutron probe calibrations, were investigated for quality and pedigree. Some data were recalculated using more defensible calibration data. Therefore, some water content profiles are different from those in the Jennings and French (2009) report. All of that information is repeated in this report for completeness. Monitoring and characterization data generally indicate that some areas of the Area G vadose zone are consistent with undisturbed conditions, with water contents of less than five percent by volume in the top two layers of the Bandelier tuff at Area G. These data also

  3. 40 CFR 63.2161 - What performance tests and other procedures must I use if I monitor brew ethanol?

    Science.gov (United States)

    2010-07-01

    ... procedures must I use if I monitor brew ethanol? 63.2161 Section 63.2161 Protection of Environment... and other procedures must I use if I monitor brew ethanol? (a) You must conduct each performance test... performance test simultaneously with brew ethanol monitoring to establish a brew-to-exhaust...

  4. The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases

    OpenAIRE

    2014-01-01

    Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance ve...

  5. Magnet tests and status of the superconducting electron cyclotron resonance source SERSE

    Energy Technology Data Exchange (ETDEWEB)

    Ciavola, G.; Gammino, S.; Cafici, M.; Castro, M.; Chines, F.; Marletta, S. [INFN-Laboratorio Nazionale del Sud, Via S. Sofia 44, 95123 Catania (Italy); Alessandria, F. [INFN-LASA, Via F.lli Cervi 201, 20090 Segrate (Midway Islands) (Italy); Bourg, F.; Briand, P.; Melin, G.; Lagnier, R.; Seyfert, P. [CEA-Departement de Recherche Fondamentale sur la Matiere Condensee, Centre detudes Nucleaires de Grenoble, 38054 Grenoble Cedex 9 (France); Gaggero, G.; Losasso, M.; Penco, R. [ANSALDO-GIE, Via N. Lorenzi 8, 16152 Genova (Italy)

    1996-03-01

    At Laboratorio Nazionale del Sud a superconducting 14.5 GHz electron cyclotron resonance (ECR) source will be used as injector for the K-800 superconducting cyclotron. The original project of its magnetic system has been upgraded by taking into account the results of the high B mode operation of the 6.4 GHz SC-ECRIS at MSU-NSCL and now the mirror field may achieve 2.7 T, which is much higher than the confining field of any other ECR source. The magnet design will allow us to operate in a wide range of magnetic configurations making it easy to tune the source. The status of the project will be outlined and the preliminary results of the tests of the superconducting magnets will be described. A brief description of the tests to be carried out on the source during the first period of operation on the test bench in Grenoble follows. {copyright} {ital 1996 American Institute of Physics.}

  6. Status and Plans for an SRF Accelerator Test Facility at Fermilab

    CERN Document Server

    Church, M; Nagaitsev, S

    2012-01-01

    A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. The facility can accommodate up to 6 cryomodules for a total beam energy of 1.5 GeV. This facility will be used to test SRF cryomodules under high intensity beam conditions, RF power equipment, instrumentation, and LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  7. Addendum to Environmental Monitoring Plan, Nevada Test Site and Support Facilities; Addendum 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-11-01

    This 1993 Addendum to the ``Environmental Monitoring Plan Nevada Test Site and Support Facilities -- 1991,`` Report No. DOE/NV/10630-28 (EMP) applies to the US Department of Energy`s (DOE`s) operations on the Continental US (including Amchitka Island, Alaska) that are under the purview of the DOE Nevada Operations Office (DOE/NV). The primary purpose of these operations is the conduct of the nuclear weapons testing program for the DOE and the Department of Defense. Since 1951, these tests have been conducted principally at the Nevada Test Site (NTS), which is located approximately 100 miles northwest of Las Vegas, Nevada. In accordance with DOE Order 5400.1, this 1993 Addendum to the EMP brings together, in one document, updated information and/or new sections to the description of the environmental activities conducted at the NTS by user organizations, operations support contractors, and the US Environmental Protection Agency (EPA) originally published in the EMP. The EPA conducts both the offsite environmental monitoring program around the NTS and post-operational monitoring efforts at non-NTS test locations used between 1961 and 1973 in other parts of the continental US. All of these monitoring activities are conducted under the auspices of the DOE/NV, which has the stated policy of conducting its operations in compliance with both the letter and the spirit of applicable environmental statutes, regulations, and standards.

  8. Performance Test of Core Protection and Monitoring Algorithm with DLL for SMART Simulator Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Bonseung; Hwang, Daehyun; Kim, Keungkoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A multi-purpose best-estimate simulator for SMART is being established, which is intended to be used as a tool to evaluate the impacts of design changes on the safety performance, and to improve and/or optimize the operating procedure of SMART. In keeping with these intentions, a real-time model of the digital core protection and monitoring systems was developed and the real-time performance of the models was verified for various simulation scenarios. In this paper, a performance test of the core protection and monitoring algorithm with a DLL file for the SMART simulator implementation was performed. A DLL file of the simulator application code was made and several real-time evaluation tests were conducted for the steady-state and transient conditions with simulated system variables. A performance test of the core protection and monitoring algorithms for the SMART simulator was performed. A DLL file of the simulator version code was made and several real-time evaluation tests were conducted for various scenarios with a DLL file and simulated system variables. The results of all test cases showed good agreement with the reference results and some features caused by algorithm change were properly reflected to the DLL results. Therefore, it was concluded that the SCOPS{sub S}SIM and SCOMS{sub S}SIM algorithms and calculational capabilities are appropriate for the core protection and monitoring program in the SMART simulator.

  9. Getting the Biggest Bang for Your Buck: Wildlife Monitoring on Shrublands of the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Derek B. [NSTec; Greger, Paul D. [NSTec

    2011-08-30

    The Nevada Test Site (NTS) covers 3,561 km2 and extends over portions of both the Mojave and Great Basin Deserts. The resulting diverse and complex flora and fauna exhibit elements of both deserts. There are 20 vegetation associations, composed primarily of shrubs, nested within 10 vegetation alliances. Of the more than 1,200 invertebrate and 339 vertebrate species found in these shrubland habitats, 267 are considered sensitive or protected/regulated by federal or state laws. Wildlife and wildlife habitat monitoring ensures NTS activities comply with all federal and state laws enacted for the protection of these valuable biological resources and provides ecological information that can be used to predict and evaluate the potential impacts of proposed projects and current activities on these resources. This paper describes the monitoring approach used at this large site. Monitoring strategies include conducting preactivity surveys, proactively monitoring sensitive species, monitoring long-term population trends, and collaborating with other agencies and biologists. Ways to make monitoring more efficient and examples of successful monitoring and collaborations are discussed.

  10. Development and Field Testing of a Multi- Antenna GPS System for Deformation Monitoring

    Institute of Scientific and Technical Information of China (English)

    Ding Xiao-li; Huang Ding-fa; Yin Jian-hua; Chen Yong-qi; C. K. Lau; Yang Yu-wen; Sun Yong-rong; Chen Wu; He Xiu-feng

    2003-01-01

    GPS has become an important technology for monitoring deformations of structures and the crust of the Earth. A limiting factor for large-scale use of GPS in such applications is however its high hardware cost. For automatic monitoring of deformations, each point to be monitored needs equipped with a set of GPS instruments. This makes many applications such as routine monitoring of landslides too expensive in most cases. A multi-antenna GPS system has been developed and tested aiming at significantly reducing the cost of GPS when used for monitoring deformations of objects such as slopes. The system uses special hardware and software to allow one GPS receiver to be used with a number of GPS antennas. One set of such equipment can therefore be used to monitor a number of points. The system normally reduces the cost of GPS hardware by a number of folds. Besides, such a system design also eases the tasks of data communication, management and system control. This paper describes the design and system configurations of the multi-antenna GPS system that has been developed by the research team. The system consists of integrated hardware and software components for data acquisition, transmission, processing, analysis and visualization. Integration of the GPS system with conventional slope monitoring systems will also be discussed in brief.

  11. Soil Water Balance and Recharge Monitoring at the Hanford Site – FY 2010 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Fayer, Michael J.; Saunders, Danielle L.; Herrington, Ricky S.; Felmy, Diana

    2010-10-27

    This report summarizes the recharge data collected in FY 2010 at five locations on the Hanford Site in southeastern Washington State. Average monthly precipitation and temperature conditions in FY 2010 were near normal and did not present an opportunity for increased recharge. The recharge monitoring data confirmed those conditions, showing normal behavior in water content, matric head, and recharge rates. Also provided in this report is a strategy for recharge estimation for the next 5 years.

  12. TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    J.E. Daw; J.L. Rempe; D.L. Knudson; T. Unruh; B.M. Chase; K.L Davis

    2012-03-01

    As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten

  13. Status monitoring and health assessment of Luhuitou fringing reef of Sanya,Hainan, China

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qiaomin; SHI Qi; CHEN Gang; FONG T C W; WONG D C C; HUANG Hui; WANG Hankui; ZHAO Meixia

    2006-01-01

    The monitoring survey and health assessment for benthic community were carried out in Luhuitou fringing reef of Sanya, Hainan, China in 2002. Monitoring survey included manta tow, line intercept transect, video transect and digital photograph. The mean live coral cover was 23.40%. Comparison of used monitoring methods showed that video transect can replace line intercept transect, and 50 m transect is better than 20 m transect in uneven coral region. Survey data and comparison with previous research work showed that Luhuitou fringing reef has been damaged severely and has a general declining trend with live coral cover from about 85% in the 1960s down to 20% in 2004,but it still has quite high biodiversity and therefore has special protection value. Main factors of Luhuitou fringing reef declining were human activities including reef rock digging and curios collecting, destructive fishing, sediment and pollutant from coastal land, and recent marine aquaculture. Only strengthening integrated management can reach improvement and restoration of Luhuitou declining coral reef ecosystem.

  14. DEVELOPMENT OF A SENSOR NETWORK TEST BED FOR ISD MATERIALS AND STRUCUTRAL CONDITION MONITORING

    Energy Technology Data Exchange (ETDEWEB)

    Zeigler, K.; Ferguson, B.; Karapatakis, D.; Herbst, C.; Stripling, C.

    2011-07-06

    The P Reactor at the Savannah River Site is one of the first reactor facilities in the US DOE complex that has been placed in its end state through in situ decommissioning (ISD). The ISD end state consists of a grout-filled concrete civil structure within the concrete frame of the original building. To evaluate the feasibility and utility of remote sensors to provide verification of ISD system conditions and performance characteristics, an ISD Sensor Network Test Bed has been designed and deployed at the Savannah River National Laboratory. The test bed addresses the DOE-EM Technology Need to develop a remote monitoring system to determine and verify ISD system performance. Commercial off-the-shelf sensors have been installed on concrete blocks taken from walls of the P Reactor Building. Deployment of this low-cost structural monitoring system provides hands-on experience with sensor networks. The initial sensor system consists of: (1) Groutable thermistors for temperature and moisture monitoring; (2) Strain gauges for crack growth monitoring; (3) Tiltmeters for settlement monitoring; and (4) A communication system for data collection. Preliminary baseline data and lessons learned from system design and installation and initial field testing will be utilized for future ISD sensor network development and deployment.

  15. Plasma paraoxonase, oxidative status level, and their relationship with asthma control test in children with asthma.

    Science.gov (United States)

    Emin, O; Hasan, A; Rusen, D M

    2015-01-01

    Assessment of asthma with a control test has been suggested as a relevant approach in recent years. However, no biomarker of systemic inflammation has been included in the assessment of asthma control. To evaluate plasma paraoxonase (PON1), total oxidant status (TOS), and total antioxidant status (TAS) levels in children with asthma according to the disease control, and the performance in the identification of uncontrolled patients. Stable asthmatic children (n=85) and healthy controls (n=55) were recruited for this study. Blood samples were collected for plasma PON1, TOS, and TAS measurements. Any contributing factors that may affect plasma PON1, TAS, and TOS levels were excluded from both groups. The diagnostic potential of these measures was evaluated using receiver operating characteristic (ROC) analysis. Comparing the asthmatic children with the control group, plasma TAS and TOS levels were significantly higher (TAS; 6.9 ± 2.1, 1.05 ± 0.32, Pasthma, respectively. Asthma Control Test (ACT) presented an AUC of 0.972 for the identification of uncontrolled asthma. PON1 and TOS levels may be systemic markers of uncontrolled asthma in children. Combined use of these two biomarkers with asthma control test may identify patients with uncontrolled asthma in children. Copyright © 2014 SEICAP. Published by Elsevier Espana. All rights reserved.

  16. Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-04-01

    This report presents the 2007 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. Requirements for CAU 443 are specified in the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada and includes groundwater monitoring in support of site closure. This is the first groundwater monitoring report prepared by DOE-LM for the CNTA The CNTA is located north of U.S. Highway 6, approximately 30 miles north of Warm Springs in Nye County, Nevada (Figure 1). Three emplacement boreholes, UC-1, UC-3, and UC-4, were drilled at the CNTA for underground nuclear weapons testing. The initial underground nuclear test, Project Faultless, was conducted in borehole UC-1 at a depth of 3,199 feet (ft) (975 meters) below ground surface on January 19, 1968. The yield of the Project Faultless test was estimated to be 0.2 to 1 megaton (DOE 2004). The test resulted in a down-dropped fault block visible at land surface (Figure 2). No further testing was conducted at the CNTA, and the site was decommissioned as a testing facility in 1973.

  17. Tonopah Test Range Air Monitoring: CY2013 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A [DRI; Nikolich, George [DRI; Shadel, Craig [DRI; McCurdy, Greg [DRI; Etyemezian, Vicken [DRI; Miller, Julianne J [DRI

    2014-10-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This test resulted in radionuclide-contaminated soils at Clean Slate I, II, and III. This report documents observations made during on-going monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III and at the TTR Range Operations Control center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soils beyond both the physical and administrative boundaries of the sites. Results for the calendar year (CY) 2013 monitoring include: (1) the gross alpha and gross beta values from the monitoring stations are approximately equivalent to the highest values observed during the CY2012 reporting at the surrounding Community Environmental Monitoring Program (CEMP) stations (this was the latest documented data available at the time of this writing); (2) only naturally occurring radionuclides were identified in the gamma spectral analyses; (3) the ambient gamma radiation measurements indicate that the average annual gamma exposure is similar at all three monitoring stations and periodic intervals of increased gamma values appear to be associated with storm fronts passing through the area; and (4) the concentrations of both resuspended dust and saltated sand particles generally increase with increasing wind speed. However, differences in the observed dust concentrations are likely due to differences in the soil characteristics immediately adjacent to the monitoring stations. Neither the resuspended particulate radiological analyses nor the ambient gamma radiation measurements suggest wind transport of radionuclide-contaminated soils.

  18. Tonopah Test Range Air Monitoring. CY2014 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Nikoloch, George [Desert Research Inst. (DRI), Las Vegas, NV (United States); Shadel, Craig [Desert Research Inst. (DRI), Las Vegas, NV (United States); Chapman, Jenny [Desert Research Inst. (DRI), Las Vegas, NV (United States); Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Etyemezian, Vicken [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2015-10-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This test resulted in radionuclide-contaminated soils at Clean Slate I, II, and III. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III and at the TTR Range Operations Control center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soils beyond both the physical and administrative boundaries of the sites. Results for the calendar year (CY) 2014 monitoring are: (1) the gross alpha and gross beta values from the monitoring stations are approximately equivalent to the highest values observed during the CY2014 reporting at the surrounding Community Environmental Monitoring Program (CEMP) stations; (2) only naturally occurring radionuclides were identified in the gamma spectral analyses; (3) the ambient gamma radiation measurements indicate that the average annual gamma exposure is similar at all three monitoring stations and periodic intervals of increased gamma values appear to be associated with storm fronts passing through the area; and (4) the concentrations of both resuspended dust and saltated sand particles generally increase with increasing wind speed. Differences in the observed dust concentrations are likely the result of differences in the soil characteristics immediately adjacent to the monitoring stations. Neither the resuspended particulate radiological analyses nor the ambient gamma radiation measurements suggest wind transport of radionuclide-contaminated soils.

  19. Complete Model-Based Equivalence Class Testing for the ETCS Ceiling Speed Monitor

    DEFF Research Database (Denmark)

    Braunstein, Cécile; Haxthausen, Anne Elisabeth; Huang, Wen-ling

    2014-01-01

    In this paper we present a new test model written in SysML and an associated blackbox test suite for the Ceiling Speed Monitor (CSM) of the European Train Control System (ETCS). The model is publicly available and intended to serve as a novel benchmark for investigating new testing theories......_nite cardinality of the input domains { is capable to produce _nite test suites that are complete (i.e. sound and exhaustive) for a given fault model. In this paper, an overview of the model and the equivalence class testing strategy is given, and tool-based evaluation results are presented. For the technical...... and comparing the capabilities of modelbased test automation tools. The CSM application inputs velocity values from a domain which could not be completely enumerated for test purposes with reasonable e_ort. We therefore apply a novel method for equivalence class testing that { despite the conceptually in...

  20. Tank Monitor and Control System sensor acceptance test procedure. Revision 5

    Energy Technology Data Exchange (ETDEWEB)

    Scaief, C.C. III

    1994-09-26

    The purpose of this acceptance test procedure (ATP) is to verify the correct reading of sensor elements connected to the Tank Monitor and Control System (TMACS). This ATP is intended to be used for testing of the connection of existing temperature sensors, new temperature sensors, pressure sensing equipment, new Engraf level gauges, sensors that generate a current output, and discrete (on/off) inputs. It is intended that this ATP will be used each time sensors are added to the system. As a result, the data sheets have been designed to be generic. The TMACS has been designed in response to recommendations from the Defense Nuclear Facilities Safety Board primarily for improved monitoring of waste tank temperatures. The system has been designed with the capability to monitor other types of sensor input as well.

  1. Infrared thermography: A potential noninvasive tool to monitor udder health status in dairy cows

    Directory of Open Access Journals (Sweden)

    M. Sathiyabarathi

    2016-10-01

    Full Text Available The animal husbandry and livestock sectors play a major role in the rural economy, especially for the small and marginal farmers. India has the largest livestock population in the world and ranks first in the milk production. Mastitis is the most common and expensive infectious disease in dairy cattle. The global economic losses per year due to mastitis amounts to USD 35 billion and for Indian dairy industry INR 6000 crores per year. Early detection of mastitis is very important to reduce the economic loss to the dairy farmers and dairy industry. Automated methods for early and reliable detection of mastitis are currently in focus under precision dairying. Skin surface temperature is an important indicator for the diagnosis of cow’s illnesses and for the estimation of their physiological status. Infrared thermography (IRT is a simple, effective, on-site, and noninvasive method that detects surface heat, which is emitted as infrared radiation and generates pictorial images without causing radiation exposure. In human and bovine medicine, IRT is used as a diagnostic tool for assessment of normal and physiological status.

  2. Infrared thermography: A potential noninvasive tool to monitor udder health status in dairy cows.

    Science.gov (United States)

    Sathiyabarathi, M; Jeyakumar, S; Manimaran, A; Jayaprakash, G; Pushpadass, Heartwin A; Sivaram, M; Ramesha, K P; Das, D N; Kataktalware, Mukund A; Prakash, M Arul; Kumar, R Dhinesh

    2016-10-01

    The animal husbandry and livestock sectors play a major role in the rural economy, especially for the small and marginal farmers. India has the largest livestock population in the world and ranks first in the milk production. Mastitis is the most common and expensive infectious disease in dairy cattle. The global economic losses per year due to mastitis amounts to USD 35 billion and for Indian dairy industry ₹6000 crores per year. Early detection of mastitis is very important to reduce the economic loss to the dairy farmers and dairy industry. Automated methods for early and reliable detection of mastitis are currently in focus under precision dairying. Skin surface temperature is an important indicator for the diagnosis of cow's illnesses and for the estimation of their physiological status. Infrared thermography (IRT) is a simple, effective, on-site, and noninvasive method that detects surface heat, which is emitted as infrared radiation and generates pictorial images without causing radiation exposure. In human and bovine medicine, IRT is used as a diagnostic tool for assessment of normal and physiological status.

  3. Non-invasive monitoring of endocrine status in laboratory primates: methods, guidelines and applications

    Science.gov (United States)

    Heistermann, M.

    2010-11-01

    During the past three decades, non-invasive methods for assessing physiological, in particular endocrine, status have revolutionized almost all areas of primatology, including behavioural ecology, reproductive biology, stress research, conservation and last but not least management of primates in captivity where the technology plays an integral role in assisting the husbandry, breeding and welfare of many species. Non-invasive endocrine methods make use of the fact that hormones circulating in blood are secreted into saliva or deposited in hair and are eliminated from the body via urinary and faecal excretion. The choice of which matrix to use for hormonal assessment depends on a range of factors, including the type of information required, the measurement techniques involved, species differences in hormone metabolism and route of excretion and the practicality of sample collection. However, although sample collection is usually relatively easy, analysing hormones from these non-invasively collected samples is not as easy as many people think, particularly not when dealing with a new species. In this respect, the importance of a careful validation of each technique is essential in order to generate meaningful and accurate results. This paper aims to provide an overview of the available non-invasive endocrine-based methodologies, their relative merits and their potential areas of application for assessing endocrine status in primates, with special reference to captive environments. In addition, general information is given about the most important aspects and caveats researchers have to be aware of when using these methodologies.

  4. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    BACKGROUND: Physical exercise is generally recommended as part of life style changes post stroke. Monitoring cardiovascular effects may help motivate patients for further exercise, and can be an instrument to assess intervention effects in clinical trials. In 1 of 4 stroke patients, the heart rat...

  5. Tank Monitor and Control System (TMACS) Rev 11.0 Acceptance Test Review

    Energy Technology Data Exchange (ETDEWEB)

    HOLM, M.J.

    1999-08-25

    The purpose of this document is to describe tests performed to validate Revision 11 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  6. Behavioral measures and EEG monitoring using the Brain Symmetry Index during the Wada test in children

    NARCIS (Netherlands)

    Peters, Jurriaan M.; Tomas-Fernandez, Meritxell; Putten, van Michel J.A.M.; Loddenkemper, Tobias

    2012-01-01

    EEG monitoring is used routinely during the Wada test in children. We quantified EEG asymmetry using the Brain Symmetry Index (BSI) to reduce subjectivity of EEG interpretation. Clinical and procedural variables were obtained and EEG data were retrieved from 46 patients with a total of 89 injections

  7. What Constrains the Accuracy of Metacomprehension Judgments? Testing the Transfer-Appropriate-Monitoring and Accessibility Hypotheses

    Science.gov (United States)

    Dunlosky, J.; Rawson, K.A.; Middleton, E.L.

    2005-01-01

    We evaluated two hypotheses-transfer appropriate monitoring (TAM) and the accessibility hypothesis-that explain why the accuracy of metacomprehension judgments is commonly low. In 2 experiments, participants read six expository texts, made global judgments about how well they would perform on a test over each text, and made term-specific judgments…

  8. Out-of-Pile Thermal Simulation Test of Temperature Monitors Used in CEFR

    Institute of Scientific and Technical Information of China (English)

    HUANG; Chen; SU; Yan-jing; CUI; Chao

    2012-01-01

    <正>Eutectic alloys are often used for passive temperature monitoring of irradiation experiments. The irradiation temperature is estimated according to the melting state of the eutectic alloys. The temperature range of materials irradiation test in China Experimental Fast Reactor (CEFR) is around 450-650 ℃. The alloys used

  9. Monitoring and analysis of bovine spongiform encephalopathy (BSE) testing in Denmark using statistical models

    DEFF Research Database (Denmark)

    Paisley, Larry

    2002-01-01

    The evolution of monitoring and surveillance for bovine spongiform encephalopathy (BSE) from the phase of passive surveillance that began in the United Kingdom in 1988 until the present is described. Currently, surveillance for BSE in Europe consists of mass testing of cattle slaughtered for human...

  10. Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Leibfritz, J.; Andrews, R.; Baffes, C.M.; Carlson, K.; Chase, B.; Church, M.D.; Harms, E.R.; Klebaner, A.L.; Kucera, M.; Martinez, A.; Nagaitsev, S.; /Fermilab

    2012-05-01

    The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  11. Induced plant volatiles allow sensitive monitoring of plant health status in greenhouses.

    Science.gov (United States)

    Jansen, Roel M C; Hofstee, Jan W; Wildt, Jürgen; Verstappen, Francel W A; Bouwmeester, Harro J; van Henten, Eldert J

    2009-09-01

    A novel approach to support the inspection of greenhouse crops is based on the measurement of volatile organic compounds emitted by unhealthy plants. This approach has attracted some serious interest over the last decade. In pursuit of this interest, we performed several experiments at the laboratory-scale to pinpoint marker volatiles that can be used to indicate certain health problems. In addition to these laboratory experiments, pilot and model studies were performed in order to verify the validity of these marker volatiles under real-world conditions. This paper provides an overview of results and gives an outlook on the use of plant volatiles for plant health monitoring.

  12. Status of GRB Observations with the Suzaku Wideband All-sky Monitor

    CERN Document Server

    Tashiro, M S; Urata, Y; Onda, K; Kodaka, N; Endo, A; Suzuki, M; Morigami, K; Yamaoka, K; Nakagawa, Y E; Sugita, S; Fukazawa, Y; Ohno, M; Takahashi, T; Kira, C; Uehara, T; Tamagawa, T; Enoto, T; Miyawaki, R; Nakazawa, K; Makishima, K; Sonoda, E; Yamauchi, M; Maeno, S; Tanaka, H; Hara, R; Suzuki, M; Kokubun, M; Takahashi, T; Hong, S J; Murakami, T; Tajima, H

    2008-01-01

    The Wide-band All-sky Monitor (WAM) is a function of the large lateral BGO shield of the Hard X-ray Detector (HXD) onboard Suzaku. Its large geometrical area of 800 cm^2 per side, the large stopping power for the hard X-rays and the wide-field of view make the WAM an ideal detector for gamma-ray bursts (GRBs) observations in the energy range of 50-5000 keV. In fact, the WAM has observed 288 GRBs confirmed by other satellites, till the end of May 2007.

  13. Immunoassay-Based Drug Tests Are Inadequately Sensitive for Medication Compliance Monitoring in Patients Treated for Chronic Pain.

    Science.gov (United States)

    Snyder, Marion L; Fantz, Corrine R; Melanson, Stacy

    2017-02-01

    Enzyme immunoassays (EIA) have notable limitations for monitoring therapeutic compliance in pain management. Chromatography coupled with mass spectrometry provides definitive results and superior sensitivity and specificity over traditional EIA testing. To analyze and compare the sensitivity of EIA results together with known prescriptions to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for monitoring drug use (and abuse) in patients treated for chronic pain. A total of 530 urine samples from patients being treated for chronic pain were studied. Pain management clinic in the United States. The samples were tested for a profile of chronic pain medications and illicit drugs with commercially available EIA kits followed by analysis with Agilent LC-MS/MS system. The EIAs exhibited poor sensitivity and high rates of false negative results in the pain management setting. For example, 21% of EIA for opiates show false negative results. Mass spectrometry methods were more sensitive, detected a broader range of drugs and metabolites, and could detect non-prescribed drug use and simulations in compliance. Patients do not always accurately report drug use information, and some drugs do not have EIA methods available for comparative purposes. Mass spectrometry is a more robust and reliable method for detection of drugs used in the pain management setting. Due to the extent of undisclosed use and abuse of medications and illicit drugs, LC-MS/MS testing is necessary for adequate and accurate drug detection. In addition, LC-MS/MS methods are superior in terms of sensitivity and number of compounds that can be screened, making this a better method for use in pain management. Key words: Pain management, enzyme immunoassays, mass spectrometry, urine drug testing, prescription status, compliance.

  14. Confidence judgments in real classroom settings: monitoring performance in different types of tests.

    Science.gov (United States)

    de Carvalho Filho, Moisés Kirk

    2009-04-01

    During testing, students have a valuable opportunity to exercise and improve their self-regulatory skills. However, the extent to which they profit from those experiences may vary according to some personal, test-related, and environmental factors. This study investigated the effects of metacognitive skills and test types on students' test performances, confidence judgments, and on the accuracy of those judgments. A sample of 129 psychology undergraduate students (50 men and 79 women, mean age = 18.9 years) were categorized according to their metacognitive skills (high vs average vs low) and had their test performances and monitoring processes in two different types of tests (i.e., multiple-choice and short-answer tests) compared throughout one academic term. Their test preparation practices, along with their attributional and regulatory processes during test-taking, were also compared by using open-ended questions. The results showed that: (1) high-metacognitive students presented more effective test preparation practices, better test performances, and superior attributional, regulatory, and monitoring processes than their counterparts; (2) differences in performance and judgment accuracy were significantly larger in the short-answer tests than in the multiple-choice tests; and (3) over time, students' performances and confidence levels varied in specific patterns according to the type of test being taken. The results are discussed, focusing on the educational implications of the interactions observed and on how they may determine what students can learn from test-taking experiences. In addition, based on the results obtained, specific suggestions on how to increase the metacognitive awareness of university students through instruction and on how to improve their academic assessment are provided.

  15. Training status (endurance or sprint) and catecholamine response to the Wingate-test in women.

    Science.gov (United States)

    Jacob, C; Zouhal, H; Vincent, S; Gratas-Delamarche, A; Berthon, P M; Bentué-Ferrer, D; Delamarche, P

    2002-07-01

    The aim of this study was to verify if, as for men, training status induces different catecholamine responses to exercise. To do this, we investigated the effect of training status (sprint or endurance) on plasma catecholamine response to a supramaximal exercise in women. Nineteen subjects took part in our study: six untrained subjects (UT), seven endurance trained subjects (ET) and six sprint trained ones (ST). The trained subjects (ET and ST) were all competing at a high national level. The maximal power (W max ) and the mean power (W) were determined from the Wingate-test. Blood lactate, adrenaline (A) and noradrenaline (NA) were analysed at rest (La 0, A 0 and NA 0 ), immediately at the end of the exercise (A max and NA max ) and after 5 min recovery (La max [3 min in arterialized blood], A 5 and NA 5 ). The disappearance of A and NA was judged by the ratio (A max -A 5 )/A max and (NA max -NA 5 )/NA 5. The ratio A max /NA max was considered as an index of the adrenal medulla responsiveness to the sympathetic nervous activity. As expected, during the Wingate-test ST exhibited significantly higher performances compared to UT and ET. But in contrast to the men's data no difference was observed between the three groups both for La max (13.1 +/- 0.8 mmol x L (-1); 14.8 +/- 1.0 mmol x L (-1) and 11.2 +/- 0.5 mmol x L (-1) respectively for ET, ST and UT), NA max (22.1 +/- 1.2 nmol x L (-1); 13.1 +/- 2.4 nmol x L (-1) and 20.2 +/- 7 nmol x L (-1)respectively for ET, ST and UT) and A max (4.1 +/- 0.8 nmol x L (-1); 2.6 +/- 0.6 nmol x L (-1); 13.1 +/- 0.6 nmol x L (-1) respectively for ET, ST and UT). Consequently the ratio A max /NA max was similar in UT, ET and ST (respectively 0.2 +/- 0.03; 0.2 +/- 0.04; 0.17 +/- 0.04), These results indicated, in contrast to the men's data, that the catecholamine response to the Wingate-test did not differ between female subjects of different status of training. In conclusion this study did not find any significant effect of training

  16. Integrating monitor alarms with laboratory test results to enhance patient deterioration prediction.

    Science.gov (United States)

    Bai, Yong; Do, Duc H; Harris, Patricia Rae Eileen; Schindler, Daniel; Boyle, Noel G; Drew, Barbara J; Hu, Xiao

    2015-02-01

    Patient monitors in modern hospitals have become ubiquitous but they generate an excessive number of false alarms causing alarm fatigue. Our previous work showed that combinations of frequently co-occurring monitor alarms, called SuperAlarm patterns, were capable of predicting in-hospital code blue events at a lower alarm frequency. In the present study, we extend the conceptual domain of a SuperAlarm to incorporate laboratory test results along with monitor alarms so as to build an integrated data set to mine SuperAlarm patterns. We propose two approaches to integrate monitor alarms with laboratory test results and use a maximal frequent itemsets mining algorithm to find SuperAlarm patterns. Under an acceptable false positive rate FPRmax, optimal parameters including the minimum support threshold and the length of time window for the algorithm to find the combinations of monitor alarms and laboratory test results are determined based on a 10-fold cross-validation set. SuperAlarm candidates are generated under these optimal parameters. The final SuperAlarm patterns are obtained by further removing the candidates with false positive rate>FPRmax. The performance of SuperAlarm patterns are assessed using an independent test data set. First, we calculate the sensitivity with respect to prediction window and the sensitivity with respect to lead time. Second, we calculate the false SuperAlarm ratio (ratio of the hourly number of SuperAlarm triggers for control patients to that of the monitor alarms, or that of regular monitor alarms plus laboratory test results if the SuperAlarm patterns contain laboratory test results) and the work-up to detection ratio, WDR (ratio of the number of patients triggering any SuperAlarm patterns to that of code blue patients triggering any SuperAlarm patterns). The experiment results demonstrate that when varying FPRmax between 0.02 and 0.15, the SuperAlarm patterns composed of monitor alarms along with the last two laboratory test results

  17. North American Land Change Monitoring System: Current Status and Future Development

    Science.gov (United States)

    Pouliot, D.; Homer, C.; Ressl, R.; Takaki, F.; Meneses, C.; Latifovic, R.; Giri, C.; Colditz, R.; Jimenez, F.; Orozco, R.; Hossain, N.; Lopez, G.; Palafox, R.; Díaz, P.

    2009-05-01

    At the Land Cover Summit meeting held in Washington, DC in September 2006 the North American Land Change Monitoring System (NLCMS) project was initiated between representatives from the US Geological Survey (USGS), the National Institute of Geographic Statistics and Information of Mexico (INEGI) and the Canada Centre for Remote Sensing (CCRS). The objective of the NALCMS is a joint effort to create a harmonized system for multi-scale and multi-temporal monitoring and reporting of North American land cover change. The proposed system couples 250m and 30m resolutions, offering products relevant at both spatial scales. The two spatial resolutions will provide users with investigation, confirmation, calibration, and assessment of 250m change products with 30m product support. This combination of spatial resolutions offers a valuable increase in temporal frequency, context, and strategic prioritization for 30m products. In due course these land change products can provide continental, national, and regional consistency to land cover and land cover change analysis.

  18. Status of contamination monitoring in radiation activities of National Atomic Energy Agency (NAEA) in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Suhariyono, Gatot [National Atomic Energy Agency, Jakarta (Indonesia)

    1997-06-01

    National Atomic Energy Agency (NAEA) or Badan Tenaga Atom Nasional (BATAN) is a non departmental governmental agency, headed by a Director General who is directly responsible to the President. Center for Standardization and Radiation Safety Research (CSRSR) is one of the research centers within the deputy for the assessment of nuclear science and technology of the NAEA. The main task of the CSRSR is to implement research and development program, development and services in the field of radiation safety, standardization, dosimetry, radiation health as well as the application of nuclear techniques in medicine, according to the policy confirmed by the director general of BATAN. Task of radiation protection division is to set up programs and to develop radiation protection, personal monitoring system and radiation level of the working areas and their surroundings as well as dose limitation system, to carry out technical up grading of radiation protection officials skill and to help coping with radiation accident. The key factor on contamination monitoring is to reduce human error and mechanical failures. These problems can be achieved to the highest degree by developing knowledge and skill of staffs via trainings or courses on contamination and decontamination, so that they are hoped to become trained and qualified staffs. (G.K.)

  19. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.

    Science.gov (United States)

    Khalil, Sami F; Mohktar, Mas S; Ibrahim, Fatimah

    2014-06-19

    Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.

  20. The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status Monitoring and Diagnosis of Diseases

    Directory of Open Access Journals (Sweden)

    Sami F. Khalil

    2014-06-01

    Full Text Available Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.

  1. Monitoring of iodine intake and thyroid status of pregnant women in Saratov region from 1999 till 2008

    Directory of Open Access Journals (Sweden)

    Naumova Yu.V.

    2011-03-01

    Full Text Available The article presents the results of monitoring of iodine intake and thyroid status in pregnant women in Saratov region according to the two cross-sectional studies in 1999 and 2008. The study involved 229 pregnant women. It has been established that there is a decrease in frequency of endemic goiter in pregnant women from 52,8 to 23,6% and increase in median urinary ioduria from 33,0 to 115,5 ug/l. However, iodine intake in pregnancy remains insufficient, as currently the median urinary ioduria is 150-249 ug/l (WHO, 2007. The frequency of maternal hypothyroxinemia, the most significant iodine deficiency disorders in pregnant women, has not changed in a 10-year period (1999 - 46,3%; in 2008 - 55,7%; p>0,1. The research has not obtained significant differences in the frequency of interrelated with pregnancy and delivery complications within two groups of patients

  2. Changing pattern of agitated impaired mental status in patients with advanced cancer: association with cognitive monitoring, hydration, and opioid rotation.

    Science.gov (United States)

    Bruera, E; Franco, J J; Maltoni, M; Watanabe, S; Suarez-Almazor, M

    1995-05-01

    In late 1990, it became standard practice at the palliative care unit of the Edmonton General Hospital to regularly administer the Mini-Mental State Questionnaire (MMSQ) and to undertake opioid rotation and hydration upon detection of cognitive failure. We retrospectively reviewed the charts of 117 and 162 patients admitted in 1988-1989 and 1991-1992, respectively, to assess the impact of these maneuvers on the prevalence of agitated impaired mental status (IMS). All patients underwent regular cognitive assessment in 1991-1992 versus none in 1988-1989. Seventy-three percent of patients received hydration in the second period versus 32% in the first (P prescriptions per patient, P monitoring, opioid rotation, and hydration may reduce the incidence of agitated IMS in terminal cancer patients.

  3. Testing of In-Line Slurry Monitors and Pulsair Mixers with Radioactive Slurries

    Energy Technology Data Exchange (ETDEWEB)

    Hylton, T.D.; Bayne, C.K.

    1999-08-01

    Three in-line slurry monitoring instruments were demonstrated, tested, and evaluated for their capability to determine the transport properties of radioactive slurries. The instruments included the Endress + Hauser Promass 63M Coriolis meter for measuring density, the Lasentec M600P for measuring particle size distribution, and a prototype ultrasonic monitor that was developed by Argonne National Laboratory for measuring suspended solids concentration. In addition, the power consumption of the recirculation pump was monitored to determine whether this parameter could be used as a tool for in-line slurry monitoring. The Promass 63M and the M600P were also evaluated as potential indicators of suspended solids concentration. In order to use the Promass 63M as a suspended solids monitor, the densities of the fluid phase and the dry solid particle phase must be known. In addition, the fluid phase density and the dry solids density must remain constant, as any change will affect the correlation between the slurry density and the suspended solids concentration. For the M600P, the particle size distribution would need to remain relatively constant. These instruments were demonstrated and tested at the Gunite and Associated Tanks Remediation Project at the Oak Ridge National Laboratory. The testing of the instruments was conducted in parallel with the testing of a Pulsair mixing system, which was used to mix the contents of the selected tank. A total of six tests were performed. A submersible pump was positioned at two depths, while the Pulsair system was operated at three mixing rates.

  4. Alternative (non-animal) methods for cosmetics testing: current status and future prospects-2010

    DEFF Research Database (Denmark)

    Adler, Sarah; Basketter, David; Creton, Stuart

    2011-01-01

    The 7th amendment to the EU Cosmetics Directive prohibits to put animal-tested cosmetics on the market in Europe after 2013. In that context, the European Commission invited stakeholder bodies (industry, non-governmental organisations, EU Member States, and the Commission's Scientific Committee...... methods would not be available in time. The selected experts were asked to analyse the status and prospects of alternative methods and to provide a scientifically sound estimate of the time necessary to achieve full replacement of animal testing. In summary, the experts confirmed that it will take...... on Consumer Safety) to identify scientific experts in five toxicological areas, i.e. toxicokinetics, repeated dose toxicity, carcinogenicity, skin sensitisation, and reproductive toxicity for which the Directive foresees that the 2013 deadline could be further extended in case alternative and validated...

  5. Tritium processing for the European test blanket systems: current status of the design and development strategy

    Energy Technology Data Exchange (ETDEWEB)

    Ricapito, I.; Calderoni, P.; Poitevin, Y. [Fusion for Energy, Barcelona (Spain); Aiello, A.; Utili, M. [ENEA, Camugnano (Italy); Demange, D. [Karlsruhe Institute of Technology - KIT, Karlsruhe (Germany)

    2015-03-15

    Tritium processing technologies of the two European Test Blanket Systems (TBS), HCLL (Helium Cooled Lithium Lead) and HCPB (Helium Cooled Pebble Bed), play an essential role in meeting the main objectives of the TBS experimental campaign in ITER. The compliancy with the ITER interface requirements, in terms of space availability, service fluids, limits on tritium release, constraints on maintenance, is driving the design of the TBS tritium processing systems. Other requirements come from the characteristics of the relevant test blanket module and the scientific programme that has to be developed and implemented. This paper identifies the main requirements for the design of the TBS tritium systems and equipment and, at the same time, provides an updated overview on the current design status, mainly focusing onto the tritium extractor from Pb-16Li and TBS tritium accountancy. Considerations are also given on the possible extrapolation to DEMO breeding blanket. (authors)

  6. Physics Goals and Status of JEM-EUSO and its Test Experiments

    CERN Document Server

    Haungs, Andreas

    2015-01-01

    The JEM-EUSO mission aims to explore the origin of the extreme energy cosmic rays (EECRs) through the observation of air-shower fluorescence light from space. The superwide-field telescope looks down from the International Space Station onto the night sky to detect UV photons (fluorescence and Cherenkov photons) emitted from air showers. Such a space detector offers the remarkable opportunity to observe a huge volume of atmosphere at once and will achieve an unprecedented statistics within a few years of operation. Several test experiments are currently in operation: e.g., one to observe the fluorescence background from the edge of the Atmosphere (EUSO-Balloon), or another to demonstrate on ground the capability of detecting air showers with a EUSO-type telescope (EUSO-TA). In this contribution a short review on the scientific objectives of the mission and an update of the instrument definition, performances and status, as well as status of the test experiments will be given.

  7. Status of JEM-EUSO and its test experiments EUSO-Balloon and TA-EUSO

    Directory of Open Access Journals (Sweden)

    Haungs Andreas

    2013-06-01

    Full Text Available The JEM-EUSO mission will explore the origin of the extreme energy cosmic rays (EECRs through the observation of their arrival directions and energies. The super-wide-field telescope looks down from the International Space Station onto the night sky to detect UV photons fluorescence and Cherenkov photons emitted from air showers generated by EECRs in the Atmosphere. Such a space detector offers the opportunity to observe a huge volume of atmosphere at once and will achieve unprecedented statistical accuracy within a few years of operation. The JEM-EUSO mission will be installed on the Japanese module of the International Space Station. Two test experiments are currently prepared; one to observe the fluorescence background from the edge of the Atmosphere (EUSO-Balloon, and the other to demonstrate, on ground, the capability of all sub-systems of the EUSO instrument (TA-EUSO. In this paper a short review on the scientific objectives and an update of the instrument definition, performances and status of the mission, as well as of the status of the two preceded test experiments will be given.

  8. The status of computerized cognitive testing in aging: A systematic review

    Science.gov (United States)

    Wild, Katherine; Howieson, Diane; Webbe, Frank; Seelye, Adriana; Kaye, Jeffrey

    2008-01-01

    Background Early detection of cognitive decline in the elderly has become of heightened importance in parallel with the recent advances in therapeutics. Computerized assessment may be uniquely suited to early detection of changes in cognition in the elderly. We present here a systematic review of the status of computer-based cognitive testing focusing on detection of cognitive decline in the aging population. Methods All studies purporting to assess or detect age-related changes in cognition or early dementia/mild cognitive impairment (MCI) by means of computerized testing were included. Each test battery was rated on availability of normative data, level of evidence for test validity and reliability, comprehensiveness, and usability. All published studies relevant to a particular computerized test were read by a minimum of two reviewers, who completed rating forms containing the above-mentioned criteria. Results Of the 18 test batteries identified from the initial search, eleven were appropriate to cognitive testing in the elderly and were subjected to systematic review. Of those 11, five were either developed specifically for application with the elderly or have been used extensively with that population. Even within the computerized testing genre, great variability existed in manner of administration, ranging from fully examiner administered to fully self-administered. All tests had at least minimal reliability and validity data, commonly reported in peer-reviewed articles. However, level of rigor of validity testing varied widely. Conclusion All test batteries exhibited some of the strengths of computerized cognitive testing: standardization of administration and stimulus presentation, accurate measures of response latencies, automated comparison in real-time with an individual’s prior performance as well as with age-related norms, and efficiencies of staffing and cost. Some, such as the MCIS, adapted complicated scoring algorithms to enhance the information

  9. Monitoring Cerebral and Renal Oxygenation Status during Neonatal Digestive Surgeries Using Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jonathan Beck

    2017-06-01

    Full Text Available BackgroundDepending on the initial pathology, hypovolemia, intra-abdominal hypertension, and sepsis are often encountered in neonatal digestive surgery. Accurate newborn monitoring during and after surgery is essential to adapt resuscitation protocols. Near infrared spectroscopy (NIRS is non-invasive and can detect hypoperfusion which indicates a low circulatory blood flow, regardless of the cause.ObjectiveEvaluating changes in cerebral and renal regional oxygen saturation during neonatal digestive surgeries, conducted according to normal practices, with commonly used monitoring parameters. Analyzing retrospectively the inter-relationships between NIRS values and mean arterial pressure (MAP values as well as pre-ductal SpO2.MethodsProspective, descriptive, monocentric study. All neonates referred for surgery were included. NIRS allows the measurement of cerebral and renal oxygenation fluctuations, as well as calculating difference in intraoperative and postoperative values.ResultsNineteen patients were included. Cerebral regional oxygen saturation (C rSO2 values were stable while renal regional oxygen saturation (R rSO2 values tended to decrease with time during surgery. Indeed, 72% of rSO2 decline episodes occurred after the first 30 min of surgery, without any significant statistical differences for the next 90 min of surgery. After surgery, the lowest average C and R rSO2 values were evidenced during the first 6 h, with 60% of C rSO2 and R rSO2 anomalies occurring in that time frame. There was no significant statistical difference observed in the following 18 h. There was a significant correlation between R rSO2 and SpO2 values (p < 0.01, but not with C rSO2 values. There was no correlation with the MAP either for the C rSO2 values or R rSO2 ones.ConclusionNIRS is a promising non-invasive bedside tool to monitor cerebral and tissue perfusion, analyzing tissue microcirculation. NIRS has its interest to guide neonatal digestive

  10. 2012 Groundwater Monitoring Report Central Nevada Test Area, Subsurface Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-04-01

    The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring are conducted as part of the subsurface corrective action strategy. The site is currently in the fourth year of the 5-year proof-of-concept period that is intended to validate the compliance boundary. Analytical results from the 2012 monitoring are consistent with those of previous years. Tritium remains at levels below the laboratory minimum detectable concentration in all wells in the monitoring network. Samples collected from reentry well UC-1-P-2SR, which is not in the monitoring network but was sampled as part of supplemental activities conducted during the 2012 monitoring, indicate concentrations of tritium that are consistent with previous sampling results. This well was drilled into the chimney shortly after the detonation, and water levels continue to rise, demonstrating the very low permeability of the volcanic rocks. Water level data from new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels have not yet recovered from the 2011 sampling event during which several thousand gallons of water were purged. It has been recommended that a low-flow sampling method be adopted for these wells to allow head levels to recover to steady-state conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from alluvial wells installed in 2009 continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to groundwater flow at the site.

  11. Design and Status of the NGNP Fuel Experiment AGR-3/4 Irradiated in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blaine Grover

    2012-10-01

    The United States Department of Energy’s Next Generation Nuclear Plant (NGNP) Advanced Gas Reactor (AGR) Fuel Development and Qualification Program will be irradiating up to seven separate low enriched uranium (LEU) tri-isotopic (TRISO) particle fuel (in compact form) experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). These irradiations and fuel development are being accomplished to support development of the next generation reactors in the United States, and will be irradiated over the next several years to demonstrate and qualify new TRISO coated particle fuel for use in high temperature gas reactors. The goals of the irradiation experiments are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post irradiation examination (PIE) and safety testing. The experiments, which will each consist of at least six separate capsules, will be irradiated in an inert sweep gas atmosphere with individual on-line temperature monitoring and control of each capsule. The sweep gas will also have on-line fission product monitoring on its effluent to track performance of the fuel in each individual capsule during irradiation. The first experiment (designated AGR-1) started irradiation in December 2006 and was completed in November 2009. The second experiment (AGR-2) started irradiation in June 2010 and is currently scheduled to be completed in April 2013. The third and fourth experiments have been combined into a single experiment designated AGR-3/4, which started its irradiation in December 2011 and is currently scheduled to be completed in November 2013. Since the purpose of this experiment is to provide data on fission product migration and retention in the NGNP reactor, the design of this experiment is

  12. A Description of the Development, Capabilities, and Operational Status of the Test SLATE Data Acquisition System at the National Transonic Facility

    Science.gov (United States)

    Cramer, Christopher J.; Wright, James D.; Simmons, Scott A.; Bobbitt, Lynn E.; DeMoss, Joshua A.

    2015-01-01

    The paper will present a brief background of the previous data acquisition system at the National Transonic Facility (NTF) and the reasoning and goals behind the upgrade to the current Test SLATE (Test Software Laboratory and Automated Testing Environments) data acquisition system. The components, performance characteristics, and layout of the Test SLATE system within the NTF control room will be discussed. The development, testing, and integration of Test SLATE within NTF operations will be detailed. The operational capabilities of the system will be outlined including: test setup, instrumentation calibration, automatic test sequencer setup, data recording, communication between data and facility control systems, real time display monitoring, and data reduction. The current operational status of the Test SLATE system and its performance during recent NTF testing will be highlighted including high-speed, frame-by-frame data acquisition with conditional sampling post-processing applied. The paper concludes with current development work on the system including the capability for real-time conditional sampling during data acquisition and further efficiency enhancements to the wind tunnel testing process.

  13. Visualization of morphological categories of colonies for monitoring of effect on induced pluripotent stem cell culture status

    Directory of Open Access Journals (Sweden)

    Risako Nagasaka

    2017-06-01

    Full Text Available From the recent advances, there are growing expectations toward the mass production of induced pluripotent stem cells (iPSCs for varieties of applications. For such type of industrial cell manufacturing, the technology which can stabilize the production efficiency is strongly required. Since the present iPSC culture is covered by delicate manual operations, there are still quality differences in produced cells from same culture protocols. To monitor the culture process of iPSCs with the quantified data to evaluate the culture status, we here introduce image-based visualization method of morphological diversity of iPSC colonies. We have set three types of experiments to evaluate the influential factors in iPSC culture technique that may disturb the undifferentiation status of iPSC colonies: (Exp. 1 technical differences in passage skills, (Exp. 2 technical differences in feeder cell preparation, and (Exp. 3 technical differences in maintenance skills (medium exchange frequency with the combination of manual removal of morphologically irregular colonies. By measuring the all existing colonies from real-time microscopic images, the heterogenous change of colony morphologies in the culture vessel was visualized. By such visualization with morphologically categorized Manhattan chart, the difference between technical skills could be compared for evaluating appropriate cell processing.

  14. Status of series production and test of the HTS current leads for Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Heller, Reinhard, E-mail: reinhard.heller@kit.edu [Karlsruhe Institute of Technology, Karlsruhe (Germany); Buscher, Klaus-Peter [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Greifswald (Germany); Drotziger, Sandra; Fietz, Walter H.; Kienzler, Andreas; Lietzow, Ralph [Karlsruhe Institute of Technology, Karlsruhe (Germany); Mönnich, Thomas [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Greifswald (Germany); Richter, Thomas [Karlsruhe Institute of Technology, Karlsruhe (Germany); Rummel, Thomas [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Greifswald (Germany); Urbach, Elisabeth [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2013-10-15

    Highlights: ► KIT is responsible for design, production and test of the HTS current leads for W7-X. In total 14 current leads with a max. current of 18.2 kA are required. ► Final acceptance test of the current leads performed at KIT using a test cryostat connected to the main vacuum vessel of the TOSKA facility. ► In general the performance of the leads is excellent and reproducible. ► Problems during series production and test related to electrical insulation, leak tightness, contact resistance between current lead and bus bar joint box. -- Abstract: The Karlsruhe Institute of Technology (KIT) is responsible for design, production and test of the High Temperature Superconductor (HTS) current leads for the stellarator Wendelstein 7-X (W7-X). In total 14 current leads with a maximum current of 18.2 kA are required. Special feature is the upside-down orientation of the current leads because of the location of the power supplies in the basement of the experimental area of W7-X. One further important requirement is the Paschen tight electrical insulation of current leads and the connection to the bus bar system. Due to some very specific manufacturing steps, budget and time restrictions, it has been mutually decided between the project partners to manufacture most of the components in house, except the HTS stacks which have been produced and delivered by industry. As the semi-finished parts were manufactured in the central workshop of KIT, the assembly of the current leads was performed in the ITEP (Institute for Technical Physics). The final acceptance test of the current leads is performed at KIT, using a dedicated test cryostat assembled beside and connected to the main vacuum vessel of the TOSKA facility. The paper describes the status of the manufacturing of the current leads. In addition attention is given to specific problems that occurred during the manufacturing and testing.

  15. Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests

    Science.gov (United States)

    Naseri, Mandana; Khayat, Akbar; Zamaheni, Sara; Shojaeian, Shiva

    2017-01-01

    Introduction: The purpose of this study was to assess the accuracy of sensibility tests by correlating it with histologic pulp condition. Methods and Materials: Assessment of clinical signs and symptoms were performed on 65 permanent teeth that were scheduled to be extracted for periodontal, prosthodontic or orthodontic reasons. The normal pulp and reversible pulpitis were considered as treatable tooth conditions while irreversible pulpitis and necrosis were considered as untreatable conditions. The teeth were then extracted and sectioned for histological analysis of dental pulp. Histologic status and classification corresponded to the treatable or untreatable pulp condition. Comparisons between histological treatable and untreatable pulp condition were performed with chi-square analysis for sensibility test responses. The positive predictive value (PPV), negative predictive value (NPV) and accuracy to detect untreatable from treatable pulp condition were calculated for each test. Results: A significant difference was detected in the normal and a sharp lingered response to heat and cold tests. There was significant difference in the negative response to EPT between histological groups. The kappa agreement coefficient between clinical and histological diagnosis of pulp condition was about 0.843 (P<0.001). The accuracy of cold and heat tests and EPT to detect treatable pulp or untreatable pulp states were 78, 74 and 62%, respectively. The sensibility tests diagnosed untreatable pulpitis with a higher probability (NPV=63%-67% -54%, PPV=83%-91% -95% for heat, cold and EPT, respectively). Conclusion: Sensibility test results were more likely to diagnose pulpal disease or untreatable pulp conditions. However, to increase the diagnostic accuracy patient history, clinical signs and symptoms and also radiographic findings in conjunction with sensibility tests must be used. The result of this small study demonstrated a good agreement between clinical and histological pulp

  16. HIE ISOLDE Alignment and monitoring system technical design and project status

    CERN Document Server

    Gayde, J C; Kautzmann, G; Leclercq, Y; Waniorek, S; Williams, L

    2012-01-01

    In the frame of the HIE ISOLDE project most of the existing ISOLDE REX line will be replaced by a superconducting linac in order to upgrade the energy and intensity of the REX ISOLDE facility at CERN. Beam-physics simulations show that the optimum linac working conditions are obtained when the main axes of the active components, RF cavities and solenoid placed inside the cryostats, are aligned and permanently monitored on the REX Nominal Beam Line (NBL) within a precision of 0.3 mm for the cavities and 0.15 mm for the solenoids at one sigma level along directions perpendicular to the beam axis. This paper presents the proposed adjustment and alignment system based on opto-electronic sensors, optics and precise mechanic elements which are used, for some of them, in various non-standard environmental conditions such as high vacuum, cryogenic temperatures.

  17. Tropospheric Emissions: Monitoring of Pollution (TEMPO) - Status and Potential Science Studies

    Science.gov (United States)

    Chance, Kelly

    2016-05-01

    TEMPO is the first NASA Earth Venture Instrument, to launch between 2019 and 2021. It measures atmospheric pollution from Mexico City and Cuba to the Canadian oil sands, and from the Atlantic to the Pacific, hourly at high spatial resolution, ~ 10 km2. It measures the key elements of air pollution chemistry. Geostationary (GEO) measurements capture the variability in the diurnal cycle of emissions and chemistry at sub-urban scale to improve emission inventories, monitor population exposure, and enable emission-control strategies. TEMPO measures the UV/visible spectra to retrieve O3, NO2, SO2, H2 CO, C2 H2 O2, H2 O, aerosols, cloud parameters, and UVB radiation. It tracks aerosol loading. It provides near-real-time air quality products. TEMPO is the North American component of the global geostationary constellation for pollution monitoring, with the European Sentinel-4 and the Korean GEMS. TEMPO studies may include: Solar-induced fluorescence from chlorophyll over land and in the ocean to study tropical dynamics, primary productivity, carbon uptake, to detect red tides, and to study phytoplankton; Measurements of stratospheric intrusions that cause air quality exceedances; Measurements at peaks in vehicle travel to capture the variability in emissions from mobile sources; Measurements of thunderstorm activity, including outflow regions to better quantify lightning NOx and O3 production; Cropland measurements follow the temporal evolution of emissions after fertilizer application and from rain-induced emissions from semi-arid soils; Measurements investigate the chemical processing of primary fire emissions and the secondary formation of VOCs and ozone; Measurements examine ocean halogen emissions and their impact on the oxidizing capacity of coastal environments; Spectra of nighttime lights are markers for human activity, energy conservation, and compliance with outdoor lighting standards intended to reduce light pollution.

  18. Hard bottom substrate monitoring Horns Rev offshore wind farm. Annual status report. 2004

    Energy Technology Data Exchange (ETDEWEB)

    Leonhard, S.B.; Pedersen, John

    2005-05-15

    Elsam and Eltra have built the offshore demonstration wind farm at Horns Rev in the North Sea. Elsam is the owner and is responsible for the operation of the wind farm. Eltra is responsible for the connection of the wind farm to the national onshore grid. In the summer months of 2002, Elsam constructed the world's largest offshore wind farm at the Danish west coast. The wind farm is located 14-20 km into the North Sea, west of Blaevands Huk. The first wind turbine foundation was in place in March 2002 and the last mono-pile was in place in August 2002 for a total of 80. The construction work was completed with the last connecting cables sluiced down in September 2002. All the wind turbines were in production in December 2002. The expected impact from the wind farm will primarily be an alternation of habitats due to the introduction of hard bottom substrates as wind mono-piles and scour protections. A continuous development in the epifouling communities will be expected together with an introduction of new or alien species in the area. The indigenous benthic community in the area of Horn Rev can be characterised by infauna species belonging to the Goniadella-Spisula community. This community is typical of sandbanks in the North Sea area, although communities in such areas are very variable and site specific. Character species used as indicators for environmental changes in the Horns Rev area are the bristle worms Goniadella bobretzkii, Ophelia borealis, Psione remota and Orbinia sertulata and the mussels Goodallia triangularis and Spisula solida. In connection with the implementation of the monitoring programme concerning the ecological impact of the introduction of hard substrate related to the Horns Rev Wind Farm, surveys on hard bottom substrates were initialised in March 2003 with monitoring conducted in September 2003 and March and September 2004. This report describes the results from surveys on hard substrates in 2004. (au)

  19. Fiber Bragg Grating-Based Performance Monitoring of Piles Fiber in a Geotechnical Centrifugal Model Test

    Directory of Open Access Journals (Sweden)

    Xiaolin Weng

    2014-01-01

    Full Text Available In centrifugal tests, conventional sensors can hardly capture the performance of reinforcement in small-scale models. However, recent advances in fiber optic sensing technologies enable the accurate and reliable monitoring of strain and temperature in laboratory geotechnical tests. This paper outlines a centrifugal model test, performed using a 60 g ton geocentrifuge, to investigate the performance of pipe piles used to reinforce the loess foundation below a widened embankment. Prior to the test, quasidistributed fiber Bragg grating (FBG strain sensors were attached to the surface of the pipe piles to measure the lateral friction resistance in real time. Via the centrifuge actuator, the driving of pipe piles was simulated. During testing, the variations of skin friction distribution along the pipe piles were measured automatically using an optical fiber interrogator. This paper represents the presentation and detailed analysis of monitoring results. Herein, we verify the reliability of the fiber optic sensors in monitoring the model piles without affecting the integrity of the centrifugal model. This paper, furthermore, shows that lateral friction resistance developed in stages with the pipe piles being pressed in and that this sometimes may become negative.

  20. The ISRM suggested methods for rock characterization, testing and monitoring 2007-2014

    CERN Document Server

    2015-01-01

    This book is a collection of ISRM suggested methods for testing or measuring properties of rocks and rock masses both in the laboratory and in situ, as well as for monitoring the performance of rock engineering structures. The first collection (Yellow Book) has been published in 1981. In order to provide access to all the Suggested Methods in one volume, the ISRM Blue Book was published in 2007 (by the ISRM via the Turkish National Group) and contains the complete set of Suggested Methods from 1974 to 2006 inclusive. The papers in this most recent volume have been published during the last seven years in international journals, mainly in Rock Mechanics and Rock Engineering. They offer guidance for rock characterization procedures and laboratory and field testing and monitoring in rock engineering. These methods provide a definitive procedure for the identification, measurement and evaluation of one or more qualities, characteristics, or properties of rocks or rock systems that produces a test result.

  1. Test and assessment method of Automotive Safety Systems (SSB) particularly to monitor traffic incidents

    Science.gov (United States)

    Pijanowski, B.; Łukjanow, S.; Burliński, R.

    2016-09-01

    The rapid development of telematics, particularly mobile telephony (GSM), wireless data transmission (GPRS) and satellite positioning (GPS) noticeable in the last decade, resulted in an almost unlimited growth of the possibilities for monitoring of mobile objects. These solutions are already widely used in the so-called “Intelligent Transport Systems” - ITS and affect a significant increase for road safety. The article describes a method of testing and evaluation of Car Safety Systems (Polish abbreviation - SSB) especially for monitoring traffic incidents, such as collisions and accidents. The algorithm of SSB testing process is also presented. Tests are performed on the dynamic test bench, part of which is movable platform with car security system mounted on it. Crash tests with a rigid obstacle are carried out instead of destructive attempts to crash test of the entire vehicle which is expensive. The tested system, depending on the simulated traffic conditions, is mounted in such a position and with the use of components, indicated by the manufacturer for the automotive safety system installation in a vehicle, for which it is intended. Then, the tests and assessments are carried out.

  2. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  3. Epilepsy as a pyridoxine-dependent condition: quantified urinary biomarkers for status evaluation and monitoring antiepileptic treatment.

    Science.gov (United States)

    Dolina, Svetlana; Margalit, Dov; Malitsky, Sergey; Pressman, Eugeny; Rabinkov, Aharon

    2012-08-01

    The study testifies an assumption on epilepsy as an inborn error of pyridoxine metabolism and suggests non-invasive quantitative biomarkers for clarified evaluation of clinical status and monitoring an individual treatment by antiepileptic drugs. Urinary parameters of pyridoxal-phosphate (PLP)-dependent tryptophan degradation and the level of 4-pyridoxic acid, the end product of pyridoxine metabolism, were measured by HPLC method with simultaneous ultraviolet and fluorimetric detection in children with different forms of epilepsy and matched healthy controls. The concentrations of compounds formed or metabolized in the course of tryptophan degradation (kynurenines, indoxyl-sulfate) along with correlations between them turned out to be quantitative biomarkers useful for both clarifying patient's clinical state and monitoring antiepileptic treatment. In particular, the value of the ratio of 4-pyridoxic acid to kynurenine appears to be an index of an experienced seizure attack, while the ratio of 3-hydroxyanthranilic acid to 3-hydroxykynurenine reflects activity of kynureninase, the enzyme of critical sensitivity to PLP supply. Growing progressively worse, epilepsy is accompanied by aggravation of PLP-dependent disturbances of tryptophan metabolism and expanding inhibition of kynureninase. The affected pyridoxine metabolism is discussed as an inborn genetic trait in epilepsy in general, rather than a specific sign of pyridoxine-dependent epilepsy solely.

  4. Implementation Method of Non-Intrusive Monitoring Mechanism for Web Services Testing

    Institute of Scientific and Technical Information of China (English)

    Lun Cai; Jing-Ling Liu; Xi Wang

    2009-01-01

    In web services testing, accessing the interactive contents of measured services and the information of service condition accurately are the key issues of system design and realization. A non-intrusive solution based on axis2 is presented to overcome the difficulty of the information retrieval in web service testing. It can be plugged in server side or client side freely to test pre-deployed or deployed web services. Moreover, it provides a monitoring interface and the corresponding subscription publication mechanism for users based on web services to support the quality assurance grounded on service-oriented architecture (SOA) application service.

  5. Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Mayhorn, Ebony T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sullivan, Greg P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Petersen, Joseph M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Baechler, Michael C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-29

    This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

  6. Use of Electrical Coductivity Sensors to monitor Health Status and Quality of Milk in Dairy Goats

    Directory of Open Access Journals (Sweden)

    Mauro Zaninelli

    2015-11-01

    Full Text Available Intramammary infection (IMI can adversely affect, in dairy goats, milk quality and milk yield leading to high economical losses. Although somatic cell count (SCC and microbiological tests could be valid approaches to detect IMI, other methods of IMI early detection may be useful to detect infected animals and to improve milk quality.The aim of this study was to test a new multivariate model developed with the fuzzy logic technology and based on the milk EC - acquired on-line for each gland by dedicated sensors - and on new qualitative and quantitative indexes derived from the spectrum of the recorded signals.Results obtained showed that the fuzzy logic model tested could achive better results than those already reached in dairy goat research. Nevertheless, further experiment and more field data could be useful to reach the best possible accuracy that this multivariate approach could show.

  7. Elsam. Offshore Wind Farm. Horns Rev. Annual status report for the environmental monitoring programme 1. January 2001 - 31. December 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-15

    As a result of the Danish Government's Energy Plan 21 a target of 5,500 MW wind power is to be erected in Denmark by 2030. 4,000 MW of these are to be placed offshore in special pointed areas with minimal impacts on the environment. In 1998 the Danish Ministry of Environment and Energy ordered two power companies, Elsam and Energi E2, to establish each a demonstration wind farm at one of the five pointed areas. The intention was to follow the environmental impacts from the wind farm and to evaluate the possibility of setting up about 1,500 MW in each area with as little impact on the environment as possible. In 1999 the two power companies were given approval to begin pre-studies of each of the two wind farms and the work on the site construction as well as the environmental impact assessment related hereto was initiated. The authorities made a number of requirements for the EIA surveys according to the EU-directive for preparation of EIA reports. In the summer of 2000 the EIA report with project description was submitted to the authorities and the project was approved in the spring of 2001. During the summer and autumn of 2001 orders were placed for the components for the wind farm, i.e. foundations, towers, wind turbines, cables etc. After having finalised the EIA, monitoring programmes of the wind farms were initiated on basis of the results of the surveys carried out during the EIA. This means that continuous surveys have been implemented for most of the environmental parameters from 1999 and till today. This annual status report for 2001 is to present the results from the annual environmental monitoring programme (the baseline studies) at Horns Rev, which form part of the monitoring programme set up for the Horns Rev project. To get a complete picture of the Danish monitoring programme for the national demonstration wind farm project it is necessary to see the report for Horns Rev and for Roedsand as a whole. The report comprises a description of the wind

  8. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sojeong, E-mail: sojung8681@postech.ac.kr; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-11

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  9. Disulfide-Linked Dinitroxides for Monitoring Cellular Thiol Redox Status through Electron Paramagnetic Resonance Spectroscopy.

    Science.gov (United States)

    Legenzov, Eric A; Sims, Stephen J; Dirda, Nathaniel D A; Rosen, Gerald M; Kao, Joseph P Y

    2015-12-01

    Intracellular thiol-disulfide redox balance is crucial to cell health, and may be a key determinant of a cancer's response to chemotherapy and radiation therapy. The ability to assess intracellular thiol-disulfide balance may thus be useful not only in predicting responsiveness of cancers to therapy, but in assessing predisposition to disease. Assays of thiols in biology have relied on colorimetry or fluorimetry, both of which require UV-visible photons, which do not penetrate the body. Low-frequency electron paramagnetic resonance imaging (EPRI) is an emerging magnetic imaging technique that uses radio waves, which penetrate the body well. Therefore, in combination with tailored imaging agents, EPRI affords the opportunity to image physiology within the body. In this study, we have prepared water-soluble and membrane-permeant disulfide-linked dinitroxides, at natural isotopic abundance, and with D,(15)N-substitution. Thiols such as glutathione cleave the disulfides, with simple bimolecular kinetics, to yield the monomeric nitroxide species, with distinctive changes in the EPR spectrum. Using the D,(15)N-substituted disulfide-dinitroxide and EPR spectroscopy, we have obtained quantitative estimates of accessible intracellular thiol in cultured human lymphocytes. Our estimates are in good agreement with published measurements. This suggests that in vivo EPRI of thiol-disulfide balance is feasible. Finally, we discuss the constraints on the design of probe molecules that would be useful for in vivo EPRI of thiol redox status.

  10. Field tests of Fibre Bragg Grating sensors incorporated into CFRP for Railway Bridge strengthening condition monitoring

    DEFF Research Database (Denmark)

    Täljsten, Björn; Kerrouche, Abdelfathe; Leighton, J

    2008-01-01

    This paper reports results obtained from an unusual situation in structural monitoring – a ‘test-to-destruction’, measuring strain using a series of fibre Bragg gratings (FBG) sensors on a decommissioned concrete Railway Bridge in Örnsköldsvik, Sweden. The study formed part of the FP6 EU funded...... the study, the FBG sensors were continuously monitored, allowing the incremental increases in the strain to be seen and through the yield point of the carbon composite reinforcement. The sensors were able to follow the resulting induced changes in strain of over a range in excess of 4000µε. The measurements...... reinforcements used in remedial repair and for monitoring better the performance of existing bridge structures....

  11. 2008 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-03-01

    This report presents the 2008 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site during fiscal year 2008. This is the second groundwater monitoring report prepared by DOE-LM for the CNTA.

  12. The World Radiation Monitoring Center of the Baseline Surface Radiation Network: Status 2017

    Science.gov (United States)

    Driemel, Amelie; König-Langlo, Gert; Sieger, Rainer; Long, Charles N.

    2017-04-01

    The World Radiation Monitoring Center (WRMC) is the central archive of the Baseline Surface Radiation Network (BSRN). The BSRN was initiated by the World Climate Research Programme (WCRP) Working Group on Radiative Fluxes and began operations in 1992. One of its aims is to provide short and long-wave surface radiation fluxes of the best possible quality to support the research projects of the WCRP and other scientific projects. The high quality, uniform and consistent measurements of the BSRN network can be used to monitor the short- and long-wave radiative components and their changes with the best methods currently available, to validate and evaluate satellite-based estimates of the surface radiative fluxes, and to verify the results of global climate models. In 1992 the BSRN/WRMC started at ETH Zurich, Switzerland with 9 stations. Since 2007 the archive is hosted by the Alfred-Wegener-Institut (AWI) in Bremerhaven, Germany (http://www.bsrn.awi.de/) and comprises a network of currently 59 stations in contrasting climatic zones, covering a latitude range from 80°N to 90°S. Of the 59 stations, 23 offer the complete radiation budget (down- and upwelling short- and long-wave data). In addition to the ftp-service access instituted at ETH Zurich, the archive at AWI offers data access via PANGAEA - Data Publisher for Earth & Environmental Science (https://www.pangaea.de). PANGAEA guarantees the long-term availability of its content through a commitment of the operating institutions. Within PANGAEA, the metadata of the stations are freely available. To access the data itself an account is required. If the scientist accepts to follow the data release guidelines of the archive (http://bsrn.awi.de/data/conditions-of-data-release/) he or she can get an account from amelie.driemel@awi.de. Currently, more than 9,400 station months (>780 years) are available for interested scientists (see also https://dataportals.pangaea.de/bsrn/?q=LR0100 for an overview on available data

  13. The status of the SNS external antenna ion source and spare RFQ test facility

    Energy Technology Data Exchange (ETDEWEB)

    Welton, R. F., E-mail: welton@ornl.gov; Aleksandrov, A. V.; Han, B. X.; Kang, Y.; Murray, S. N.; Pennisi, T. R.; Piller, C.; Santana, M.; Stockli, M. P. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, Tennessee 37830-6471 (United States); Dudnikov, V. G. [Muons, Inc., 552 N. Batavia Avenue, Batavia, Illinois 60510 (United States)

    2016-02-15

    The Oak Ridge National Laboratory operates the Spallation Neutron Source, consisting of a H{sup −} ion source, a 1 GeV linac and an accumulator ring. The accumulated <1 μs-long, ∼35 A beam pulses are extracted from the ring at 60 Hz and directed onto a liquid Hg target. Spalled neutrons are directed to ∼20 world class instruments. Currently, the facility operates routinely with ∼1.2 MW of average beam power, which soon will be raised to 1.4 MW. A future upgrade with a second target station calls for raising the power to 2.8 MW. This paper describes the status of two accelerator components expected to play important roles in achieving these goals: a recently acquired RFQ accelerator and the external antenna ion source. Currently, the RFQ is being conditioned in a newly constructed 2.5 MeV Integrated Test Facility (ITF) and the external antenna source is also being tested on a separate test stand. This paper presents the results of experiments and the testing of these systems.

  14. Development of an In-Situ Decommissioning Sensor Network Test Bed for Structural Condition Monitoring - 12156

    Energy Technology Data Exchange (ETDEWEB)

    Zeigler, Kristine E.; Ferguson, Blythe A. [Savannah River National Laboratory, Aiken, South Carolina 29808 (United States)

    2012-07-01

    The Savannah River National Laboratory (SRNL) has established an In Situ Decommissioning (ISD) Sensor Network Test Bed, a unique, small scale, configurable environment, for the assessment of prospective sensors on actual ISD system material, at minimal cost. The Department of Energy (DOE) is presently implementing permanent entombment of contaminated, large nuclear structures via ISD. The ISD end state consists of a grout-filled concrete civil structure within the concrete frame of the original building. Validation of ISD system performance models and verification of actual system conditions can be achieved through the development a system of sensors to monitor the materials and condition of the structure. The ISD Sensor Network Test Bed has been designed and deployed to addresses the DOE-Environmental Management Technology Need to develop a remote monitoring system to determine and verify ISD system performance. Commercial off-the-shelf sensors have been installed on concrete blocks taken from walls of the P Reactor Building at the Savannah River Site. Deployment of this low-cost structural monitoring system provides hands-on experience with sensor networks. The initial sensor system consists of groutable thermistors for temperature and moisture monitoring, strain gauges for crack growth monitoring, tilt-meters for settlement monitoring, and a communication system for data collection. Baseline data and lessons learned from system design and installation and initial field testing will be utilized for future ISD sensor network development and deployment. The Sensor Network Test Bed at SRNL uses COTS sensors on concrete blocks from the outer wall of the P Reactor Building to measure conditions expected to occur in ISD structures. Knowledge and lessons learned gained from installation, testing, and monitoring of the equipment will be applied to sensor installation in a meso-scale test bed at FIU and in future ISD structures. The initial data collected from the sensors

  15. Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

    Science.gov (United States)

    Seaman, Calvin H.; Brower, David V.; Le, Suy Q.; Tang, Henry H.

    2015-01-01

    This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

  16. Propulsion health monitoring of a turbine engine disk using spin test data

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark; Oza, Nikunj; Matthews, Bryan; Baakilini, George

    2010-03-01

    On line detection techniques to monitor the health of rotating engine components are becoming increasingly attractive options to aircraft engine companies in order to increase safety of operation and lower maintenance costs. Health monitoring remains a challenging feature to easily implement, especially, in the presence of scattered loading conditions, crack size, component geometry and materials properties. The current trend, however, is to utilize noninvasive types of health monitoring or nondestructive techniques to detect hidden flaws and mini cracks before any catastrophic event occurs. These techniques go further to evaluate materials' discontinuities and other anomalies that have grown to the level of critical defects which can lead to failure. Generally, health monitoring is highly dependent on sensor systems that are capable of performing in various engine environmental conditions and able to transmit a signal upon a predetermined crack length, while acting in a neutral form upon the overall performance of the engine system. Efforts are under way at NASA Glenn Research Center through support of the Intelligent Vehicle Health Management Project (IVHM) to develop and implement such sensor technology for a wide variety of applications. These efforts are focused on developing high temperature, wireless, low cost and durable products. Therefore, in an effort to address the technical issues concerning health monitoring of a rotor disk, this paper considers data collected from an experimental study using high frequency capacitive sensor technology to capture blade tip clearance and tip timing measurements in a rotating engine-like-disk-to predict the disk faults and assess its structural integrity. The experimental results collected at a range of rotational speeds from tests conducted at the NASA Glenn Research Center's Rotordynamics Laboratory will be evaluated using multiple data-driven anomaly detection techniques to identify anomalies in the disk. This study

  17. [Blood pressure monitoring - Status quo and future : A contribution to the personalized medicine].

    Science.gov (United States)

    Engelmann, L; Kunig, S; Kunig, H

    2016-10-01

    Sustainment of life demands that the heart create sufficient pressure to maintain enough flow to keep the body healthy and oxygenated. Blood pressures can be easily measured, while volume measurements required additional invasive procedures. In analogy to volumetrically determined ejection fraction, a pressure ejection fraction EF(P) may be calculated. When standardized to heart rate and body surface area, a new, effective performance metric may be defined. These metrics enable the long-term monitoring of the critically ill patient. When presented in a performance diagram, the metrics contain prognostic implications and enable a real-time evaluation of the efficacy of therapeutic measures. Until now, pressure-related prognostic statements were based on statistical averages, which by definition apply to groups. With this new analytical approach, we have the ability to provide patient-specific therapeutics in an area of medicine that requires individualized treatment. Here, we show preliminary results of applying a mathematical risk analysis to blood pressure metrics to assess therapeutic risk.

  18. Monitoring fatigue status with HRV measures in elite athletes: an avenue beyond RMSSD?

    Directory of Open Access Journals (Sweden)

    Laurent eSchmitt

    2015-11-01

    Full Text Available Among the tools proposed to assess the athlete’s ‘fatigue’, the analysis of heart rate variability (HRV provides an indirect evaluation of the settings of autonomic control of heart activity. HRV analysis is performed through assessment of time-domain indices, the square root of the mean of the sum of the squares of differences between adjacent normal R-R intervals (RMSSD measured during short (5 min recordings in supine position upon awakening in the morning and particularly the logarithm of RMSSD (LnRMSSD has been proposed as the most useful resting HRV indicator. However, if RMSSD can help the practitioner to identify a global ‘fatigue’ level, it does not allow discriminating different types of fatigue. Recent results using spectral HRV analysis highlighted firstly that HRV profiles assessed in supine and standing positions are independent and complementary; and secondly that using these postural profiles allows the clustering of distinct sub-categories of ‘fatigue’. Since cardiovascular control settings are different in standing and lying posture, using the HRV figures of both postures to cluster fatigue state embeds information on the dynamics of control responses. Such HRV spectral analysis appears more sensitive and enlightening than time-domain HRV indices. The wealthier information provided by this spectral analysis should improve the monitoring of the adaptive training-recovery process in athletes.

  19. Test-retest of computerized health status questionnaires frequently used in the monitoring of knee osteoarthritis

    DEFF Research Database (Denmark)

    Gudbergsen, Henrik; Bartels, Else M.; Krusager, Peter

    2011-01-01

    .99. Analysis revealed a statistically significant difference between versions of the ADL Taxonomy, but not for the remaining questionnaires. Age, computer experience or education-level had no significant impact on the results. The computerized questionnaires were reported to be easier to use. CONCLUSION......ABSTRACT: BACKGROUND: To compare data based on touch screen to data based on traditional paper versions of questionnaires frequently used to examine patient reported outcomes in knee osteoarthritis patients and to examine the impact of patient characteristics on this comparison METHODS...... subgroups, completing either the paper or touch screen version first. Mean, mean differences (95% CI), median, median differences and Intraclass Correlation Coefficients (ICCs) were calculated for all questionnaires. RESULTS: ICCs between data based on computerized and paper versions ranged from 0.86 to 0...

  20. Testing an innovative framework for flood forecasting, monitoring and mapping in Europe

    Science.gov (United States)

    Dottori, Francesco; Kalas, Milan; Lorini, Valerio; Wania, Annett; Pappenberger, Florian; Salamon, Peter; Ramos, Maria Helena; Cloke, Hannah; Castillo, Carlos

    2017-04-01

    Between May and June 2016, France was hit by severe floods, particularly in the Loire and Seine river basins. In this work, we use this case study to test an innovative framework for flood forecasting, mapping and monitoring. More in detail, the system integrates in real-time two components of the Copernicus Emergency mapping services, namely the European Flood Awareness System and the satellite-based Rapid Mapping, with new procedures for rapid risk assessment and social media and news monitoring. We explore in detail the performance of each component of the system, demonstrating the improvements in respect to stand-alone flood forecasting and monitoring systems. We show how the performances of the forecasting component can be refined using the real-time feedback from social media monitoring to identify which areas were flooded, to evaluate the flood intensity, and therefore to correct impact estimations. Moreover, we show how the integration with impact forecast and social media monitoring can improve the timeliness and efficiency of satellite based emergency mapping, and reduce the chances of missing areas where flooding is already happening. These results illustrate how the new integrated approach leads to a better and earlier decision making and a timely evaluation of impacts.

  1. Current status of technology development for fabrication of Indian Test Blanket Module (TBM) of ITER

    Energy Technology Data Exchange (ETDEWEB)

    Jayakumar, T., E-mail: tjk@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam 603102 (India); Rajendra Kumar, E. [TBM Division, Institute for Plasma Research (IPR), Bhat, Gandhinagar 382428 (India)

    2014-10-15

    Highlights: • Status of technology developments for Indian TBM to be installed in ITER is presented. • Procedure development for EB, laser and laser-hybrid welding of RAFM steel presented. • Filler wires for RAFM steel for TIG, NG-TIG and laser-hybrid welding have been developed. • Feasibility of production of channel plate by HIP technology has been demonstrated. - Abstract: Ever since India decided to install its Lead-Lithium Ceramic Breeder (LLCB) TBM in ITER, various technologies for fabrication of Indian TBM are being pursued by IPR and IGCAR, in collaboration with various research laboratories in India. Welding consumables for joining India specific RAFM steels (IN-RAFMS), procedures for hot isostatic pressing, electron beam welding, laser and laser-hybrid welding have been developed. Considering the complex nature and limited access available for inspection, innovative inspection procedures that involved use of phased array ultrasonic and C-scan imaging are also being pursued. This paper presents the current status of these developments and provides a roadmap for the future activities planned in realizing Indian TBM for testing in ITER.

  2. Oxygen challenge test in septic shock patients: prognostic value and influence of respiratory status.

    Science.gov (United States)

    Mari, Arnaud; Vallée, Fabrice; Bedel, Jérome; Riu, Béatrice; Ruiz, Jean; Sanchez-Verlaan, Pascale; Geeraerts, Thomas; Génestal, Michèle; Silva, Stein; Fourcade, Olivier

    2014-06-01

    Transcutaneous oxygen pressure (PtcO2) value in response to an increase of FiO2 or oxygen challenge test (OCT) in ventilated patients has been reported to be related to peripheral perfusion and outcome during septic shock. However, patients with sepsis-related acute respiratory distress syndrome could demonstrate compromised arterial oxygenation with OCT impairment decoupled to circulatory failure. The aims of this study were to confirm the prognostic value of OCT and to explore the influence of respiratory status on OCT results. This was a prospective study set in an intensive care unit of a tertiary teaching hospital. Fifty-six mechanically ventilated patients with septic shock criteria were studied. Transcutaneous oxygen pressure was measured at baseline and after OCT, at intensive care unit admittance (T0), and 24 h later (T24). Survival at day 28 and hemodynamic and respiratory parameters were analyzed and compared according to outcome and respiratory status. Central hemodynamic parameters or static transcutaneous data did not differ between survivors and nonsurvivors at enrollment. The OCT was statistically different at T24 according to outcome (P < 0.001), but sensitivity was low (53%). Moreover, patients with low OCT results at T24 exhibited more severe respiratory failure (P < 0.01). The OCT at T24 is related to outcome but is influenced by the severity of respiratory failure. Our results suggest considering with caution hemodynamic management based on OCT in septic shock patients with altered pulmonary function.

  3. Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Nikolich, George [Nevada University, Reno, NV (United States). Desert Research Inst.; Shadel, Craig [Nevada University, Reno, NV (United States). Desert Research Inst.; Chapman, Jenny [Nevada University, Reno, NV (United States). Desert Research Inst.; McCurdy, Greg [Nevada University, Reno, NV (United States). Desert Research Inst.; Etyemezian, Vicken [Nevada University, Reno, NV (United States). Desert Research Inst.; Miller, Julianne J. [Nevada University, Reno, NV (United States). Desert Research Inst.; Mizell, Steve [Nevada University, Reno, NV (United States). Desert Research Inst.

    2016-09-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. Radionuclide assessment of airborne particulates in 2015 found the gross alpha and gross beta values of dust collected from the filters at the monitoring stations are consistent with background conditions. The meteorological and particle monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites and that, although the transport of radionuclide-contaminated soil by suspension has not been detected, movement by saltation is occurring.

  4. The design of an intelligent human-computer interface for the test, control and monitor system

    Science.gov (United States)

    Shoaff, William D.

    1988-01-01

    The graphical intelligence and assistance capabilities of a human-computer interface for the Test, Control, and Monitor System at Kennedy Space Center are explored. The report focuses on how a particular commercial off-the-shelf graphical software package, Data Views, can be used to produce tools that build widgets such as menus, text panels, graphs, icons, windows, and ultimately complete interfaces for monitoring data from an application; controlling an application by providing input data to it; and testing an application by both monitoring and controlling it. A complete set of tools for building interfaces is described in a manual for the TCMS toolkit. Simple tools create primitive widgets such as lines, rectangles and text strings. Intermediate level tools create pictographs from primitive widgets, and connect processes to either text strings or pictographs. Other tools create input objects; Data Views supports output objects directly, thus output objects are not considered. Finally, a set of utilities for executing, monitoring use, editing, and displaying the content of interfaces is included in the toolkit.

  5. Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

    Science.gov (United States)

    Zuniga, David; Hornung, Steven D.; Haas, Jon P.; Graf, John C.

    2009-01-01

    Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

  6. Hard bottom substrate monitoring Horns Rev offshore wind farm. Annual status report 2003

    Energy Technology Data Exchange (ETDEWEB)

    Leonhard, S.B.; Pedersen, John

    2004-05-15

    Elsam and Eltra built the offshore demonstration wind farm at Horns Rev in the North Sea. Elsam is the owner and is responsible for the operation of the wind farm. Eltra is responsible for the connection of the wind farm to the national onshore grid. In the summer months of 2002, Elsam constructed the world's largest offshore wind farm off the Danish west coast. The wind farm is sited 14-20 km into the North Sea, west of Blaevands Huk. The first wind turbine was erected in May 2002 and the last wind turbine tower of a total of 80 was in place by August 2002. The construction work was completed with the last connecting cables sluiced down in September 2002. All the wind turbines were in production by December 2002. The expected impact of the wind farm will primarily be an alternation of habitats due to the introduction of hard bottom substrates as wind turbine towers and scour protections. A continuous development in the epifouling communities will be expected together with an introduction of new or alien species in the area. The indigenous benthic community in the area of Horns Rev can be characterised by infauna species belonging to the Goniadella-Spisula community. This community is typical of sandbanks in the North Sea area, although communities in such areas are very variable and site-specific. Character species used as indicators for environmental changes in the Horns Rev area are the bristle worms Goniadella bobretzkii, Ophelia borealis, Psione remota and Orbinia sertulata and the mussels Goodallia triangularis and Spisula solida. In connection with the implementation of the monitoring programme concerning the ecological impact of the introduction of hard substrate related to the Horns Rev Wind Farm, surveys on hard bottom substrate was conducted in March 2003 and in September 2003. This report describes the first year results of surveys on hard substrate after the completion of the offshore wind farm at Horns Rev. (au)

  7. Monitoring the status of forests and rangelands in the Western United States using ecosystem performance anomalies

    Science.gov (United States)

    Rigge, Matthew B.; Wylie, Bruce; Gu, Yingxin; Belnap, Jayne; Phuyal, Khem P.; Tieszen, Larry

    2013-01-01

    The effects of land management and disturbance on ecosystem performance (i.e. biomass production) are often confounded by those of weather and site potential. The current study overcomes this issue by calculating the difference between actual and expected ecosystem performance (EEP) to generate ecosystem performance anomalies (EPA). This study aims to delineate and quantify average EPA from 2000–2009 within the Greater Platte and Upper Colorado River Basins, USA. Moderate Resolution Imaging Spectroradiometer (MODIS) normalized difference vegetation index (NDVI) images averaged over the growing season (GSN) served as a proxy of actual ecosystem performance. Yearly EEP was determined with rule-based piecewise regression tree models of abiotic data (climate, soils, elevation, etc.), independently created for each land cover. EPA were calculated as the residuals of the EEP to GSN relationship, and characterized as normal performing, underperforming, and overperforming at the 90% confidence level. Validation revealed that EPA values were related to biomass production (R2 = 0.56, P = 0.02) and likely to the proportion of biomass removed by livestock in the Nebraska Sandhills. Overall, 60.6% of the study area was (normal) performing near its EEP, 3.0% was severely underperforming, 5.0% was highly overperforming, and the remainder was slightly underperforming or overperforming. Generally, disturbances such as fires, floods, and insect damage, in addition to high grazing intensity, result in a negative EPA. Conversely, mature stands and appropriate management often result in positive EPA values. This method provides information critical to land managers to evaluate the appropriateness of previous management practices and restoration efforts and quantify disturbance impacts. Results are at a scale sufficient for many of the large management units of the region and for locating areas needing further investigation. Applications of EPA data to monitoring invasive species

  8. Monitoring and adaptive resistance management in Australia for Bt-cotton: current status and future challenges.

    Science.gov (United States)

    Downes, Sharon; Mahon, Rod; Olsen, Karen

    2007-07-01

    In the mid-1990 s the Australian Cotton industry adopted an insect-resistant variety of cotton (Ingard) which expresses the Bt toxin Cry1Ac that is specific to a group of insects including the target Helicoverpa armigera. A conservative resistance management plan (RMP), that restricted the area planted to Ingard, was implemented to preserve the efficacy of Cry1Ac until two-gene transgenic cotton was available. In 2004/05 Bollgard II replaced Ingard as the transgenic cotton available in Australia. It improves on Ingard by incorporating an additional insecticidal protein (Cry2Ab). If an appropriate refuge is grown, there is no restriction on the area planted to Bollgard II. In 2004/05 and 2005/06 the Bollgard II acreage represented approximately 80 of the total area planted to cotton in Australia. The sensitivity of field-collected populations of H. armigera to Bt products was assayed before and subsequent to the widespread deployment of Ingard cotton. In 2002 screens against Cry2Ab were developed in preparation for replacement of Ingard with Bollgard II. There have been no reported field failures of Bollgard II due to resistance. However, while alleles that confer resistance to H. armigera in the field are rare for Cry1Ac, they are surprisingly common for Cry2Ab. We present an overview of the current approach adopted in Australia to monitor and adaptively manage resistance to Bt-cotton in field populations of H. armigera and discuss the implications of our findings to date. We also highlight future challenges for resistance management in Australia, many of which extend to other Bt-crop and pest systems.

  9. A Method to Derive Monitoring Variables for a Cyber Security Test-bed of I and C System

    Energy Technology Data Exchange (ETDEWEB)

    Han, Kyung Soo; Song, Jae Gu; Lee, Joung Woon; Lee, Cheol Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In the IT field, monitoring techniques have been developed to protect the systems connected by networks from cyber attacks and incidents. For the development of monitoring systems for I and C cyber security, it is necessary to review the monitoring systems in the IT field and derive cyber security-related monitoring variables among the proprietary operating information about the I and C systems. Tests for the development and application of these monitoring systems may cause adverse effects on the I and C systems. To analyze influences on the system and safely intended variables, the construction of an I and C system Test-bed should be preceded. This article proposes a method of deriving variables that should be monitored through a monitoring system for cyber security as a part of I and C Test-bed. The surveillance features and the monitored variables of NMS(Network Management System), a monitoring technique in the IT field, were reviewed in section 2. In Section 3, the monitoring variables for an I and C cyber security were derived by the of NMS and the investigation for information used for hacking techniques that can be practiced against I and C systems. The monitoring variables of NMS in the IT field and the information about the malicious behaviors used for hacking were derived as expected variables to be monitored for an I and C cyber security research. The derived monitoring variables were classified into the five functions of NMS for efficient management. For the cyber security of I and C systems, the vulnerabilities should be understood through a penetration test etc. and an assessment of influences on the actual system should be carried out. Thus, constructing a test-bed of I and C systems is necessary for the safety system in operation. In the future, it will be necessary to develop a logging and monitoring system for studies on the vulnerabilities of I and C systems with test-beds.

  10. [Current status of the predictive genetic testing for hereditary neurological diseases in Shinshu University Hospital].

    Science.gov (United States)

    Tanaka, Keiko; Sekijima, Yoshiki; Yoshida, Kunihiro; Mizuuchi, Asako; Yamashita, Hiromi; Tamai, Mariko; Ikeda, Shu-ichi; Fukushima, Yoshimitsu

    2013-01-01

    The current status of predictive genetic testing for late-onset hereditary neurological diseases in Japan is largely unknown. In this study, we analyzed data from 73 clients who visited the Division of Clinical and Molecular Genetics, Shinshu University Hospital, for the purpose of predictive genetic testing. The clients consisted of individuals with family histories of familial amyloid polyneuropathy (FAP; n=30), Huntington's disease (HD; n=16), spinocerebellar degeneration (SCD; n=14), myotonic dystrophy type 1 (DM1; n=9), familial amyotrophic lateral sclerosis type 1 (ALS1; n=3), and Alzheimer's disease (AD; n=1). Forty-nine of the 73 (67.1%) clients were in their twenties or thirties. Twenty-seven of the 73 (37.0%) clients visited a medical institution within 3 months after becoming aware of predictive genetic testing. The most common reason for requesting predictive genetic testing was a need for certainty or to reduce uncertainty and anxiety. The decision-making about marriage and having a child was also a main reason in clients in the twenties and thirties. The numbers of clients who actually underwent predictive genetic testing was 22 of 30 (73.3%) in FAP, 3 of 16 (18.8%) in HD, 6 of 10 (60.0%) in SCD, 7 of 9 (77.8%) in DM1, and 0 of 3 (0%) in ALS1 (responsible gene of the disease was unknown in 4 SCD patients and an AD patient). The percentage of test usage was lower in untreatable diseases such as HD and SCD than that in FAP, suggesting that many clients changed their way of thinking on the significance of testing through multiple genetic counseling sessions. In addition, it was obvious that existence of disease-modifying therapy promoted usage of predictive genetic testing in FAP. Improvement of genetic counseling system to manage predictive genetic testing is necessary, as consultation concerning predictive genetic testing is the main motivation to visit genetic counseling clinic in many at-risk clients.

  11. GSETT 3: a test of an experimental international seismic monitoring system

    Directory of Open Access Journals (Sweden)

    F. Ringdal

    1994-06-01

    Full Text Available The UN Conference on Disarmament's Group of Scientific Experts (GSE was established in 1976 to consider international co operative measures to detect and identify seismic events. Over the years, the GSE has developed and tested several concepts for an International Seismic Monitoring System (ISMS for the purpose of assisting in the verification of a potential comprehensive test ban treaty. The GSE is now planning its third global technical test. (GSETT 3 in order to test new and revisled concepts for an ISMS. GSETT 3 wili be an unprecedented global effort to conduct an operationally realistic test of rapid collection, distribution and processing of seismie data. A global network of seismograph stations will provide data to an International Data Center, where the data will be processed an results made available to participants. The full scaIe phase of GSETT 3 is scheduled to begin in January 1995.

  12. The effects of monitoring and ability to achieve cognitive structure on the psychological distress during HIV testing.

    Science.gov (United States)

    Delaney, Eileen; O'Brien, William H

    2009-10-01

    Many people undergoing HIV testing experience substantial psychological distress. The psychological distress associated with testing may be influenced by monitoring. Monitoring refers to a strategy wherein a person tends to seek out information concerning threatening events. Furthermore, the ability to achieve cognitive structure (AACS) may influence the relationship between monitoring and psychological distress. The present study examined individuals who were undergoing HIV testing. Specifically, the researchers examined the association among monitoring and AACS on psychological distress during HIV testing. Results indicated that there was no interaction between monitoring and AACS on psychological distress. It was found that AACS was related to participants' level of psychological distress. However, the level of monitoring was not related to participants' psychological distress. Limitations of the study, clinical implications and suggestions for future research are also discussed.

  13. Concepts for Multi-Speed Rotorcraft Drive System - Status of Design and Testing at NASA GRC

    Science.gov (United States)

    Stevens, Mark A.; Lewicki, David G.; Handschuh, Robert F.

    2015-01-01

    In several studies and on-going developments for advanced rotorcraft, the need for variable/multi-speed capable rotors has been raised. Speed changes of up to 50 percent have been proposed for future rotorcraft to improve vehicle performance. A rotor speed change during operation not only requires a rotor that can perform effectively over the operating speed/load range, but also requires a propulsion system possessing these same capabilities. A study was completed investigating possible drive system arrangements that can accommodate up to a 50 percent speed change. Key drivers were identified from which simplicity and weight were judged as central. This paper presents the current status of two gear train concepts coupled with the first of two clutch types developed and tested thus far with focus on design lessons learned and areas requiring development. Also, a third concept is presented, a dual input planetary differential as leveraged from a simple planetary with fixed carrier.

  14. Radiation monitoring for the HTTR rise-to-power test (1) and (2)'

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji; Ashikagaya, Yoshinobu; Kikuchi, Toshiki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2001-02-01

    The High Temperature Engineering Test Reactor (HTTR) is the first high temperature gas-cooled research reactor in Japan. This reactor is a helium-gas-cooled and graphite-moderated reactor with a thermal output of 30 MW. The rated operation temperature of the outlet coolant is 850degC. (During high temperature test operation, this reaches 950degC). The first criticality of the HTTR was attained in November 1998. The single loaded, parallel loaded operation with a thermal output of 9 MW (called the HTTR Rise-to-Power Test (1)) was completed between September 16, 1999 and July 8, 2000. The single loaded, parallel loaded continuous operation with a thermal output of 20 MW (called the HTTR Rise-to-Power Test (2)) has also been carried out, but it was shutdown at the halfway stage by a single from the reactor, when the thermal output was 16.5 MW and the reactor outlet coolant temperature was 500degC. This report describes the radiation monitoring carried out during the HTTR Rise-to-Power Tests (1) and (2)'. The data measured by the various radiation monitors is also reported. These data will be used for the estimation of radiation levels (such as the radiation dose equivalent rate, the radioactive concentration in effluents, etc.) for the next HTTR Rise-to-Power Test, and for periodic inspections. (author)

  15. Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Scarpelli, Andrea [Univ. of Ferrara (Italy)

    2016-01-01

    Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

  16. Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Nikolich, George [Nevada University, Reno, NV (United States). Desert Research Inst.; Shadel, Craig [Nevada University, Reno, NV (United States). Desert Research Inst.; Chapman, Jenny [Nevada University, Reno, NV (United States). Desert Research Inst.; McCurdy, Greg [Nevada University, Reno, NV (United States). Desert Research Inst.; Etyemezian, Vicken [Nevada University, Reno, NV (United States). Desert Research Inst.; Miller, Julianne J. [Nevada University, Reno, NV (United States). Desert Research Inst.; Mizell, Steve [Nevada University, Reno, NV (United States). Desert Research Inst.

    2016-09-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites.

  17. Test Status for Proposed Coupling of a Gravitational Force to Extreme Type II YBCO Ceramic Superconductors

    Science.gov (United States)

    Noever, David; Li, Ning; Robertson, Tony; Koczor, Ron; Brantley, Whitt

    1999-01-01

    As a Bose condensate, superconductors provide novel conditions for revisiting previously proposed couplings between electromagnetism and gravity. Strong variations in Cooper pair electron density, large conductivity and low magnetic permeability define superconductive and degenerate condensates without the traditional density limits imposed by the Fermi energy (about 10-6 g/cu cm). Recent experiments have reported anomalous weight loss for a test mass suspended above a rotating Type II, YBCO superconductor, with the percentage change (0.05-2.1%) independent of the test mass' chemical composition and diamagnetic properties. A variation of 5 parts per 10(exp 4) was reported above a stationary (non-rotating) superconductor. In the present experiments reported using a sensitive gravimeter (resolution superconductors were stably levitated in a DC magnetic field (0.6 Tesla) subject to lateral AC fields (60 Gauss at 60 Hz) and rotation. With magnetic shielding, thermal control and buoyancy compensation, changes in acceleration were measured to be less than 2 parts in 10(exp 8) of the normal gravitational acceleration. This result puts new limits on the strength and range of the proposed coupling between high-Tc superconductors and gravity. Latest test results will be reported, along with status for future improvements and prospects.

  18. Test Status for Proposed Coupling of a Gravitational Force to Extreme Type II YBCO Ceramic Superconductors

    Science.gov (United States)

    Noever, David; Li, Ning; Robertson, Tony; Koczor, Ron; Brantley, Whitt

    1999-01-01

    As a Bose condensate, superconductors provide novel conditions for revisiting previously proposed couplings between electromagnetism and gravity. Strong variations in Cooper pair electron density, large conductivity and low magnetic permeability define superconductive and degenerate condensates without the traditional density limits imposed by the Fermi energy (about 10-6 g/cu cm). Recent experiments have reported anomalous weight loss for a test mass suspended above a rotating Type II, YBCO superconductor, with the percentage change (0.05-2.1%) independent of the test mass' chemical composition and diamagnetic properties. A variation of 5 parts per 10(exp 4) was reported above a stationary (non-rotating) superconductor. In the present experiments reported using a sensitive gravimeter (resolution YBCO superconductors were stably levitated in a DC magnetic field (0.6 Tesla) subject to lateral AC fields (60 Gauss at 60 Hz) and rotation. With magnetic shielding, thermal control and buoyancy compensation, changes in acceleration were measured to be less than 2 parts in 10(exp 8) of the normal gravitational acceleration. This result puts new limits on the strength and range of the proposed coupling between high-Tc superconductors and gravity. Latest test results will be reported, along with status for future improvements and prospects.

  19. On the development and testing of a guided ultrasonic wave array for structural integrity monitoring

    OpenAIRE

    Fromme, P.; Wilcox, P. D.; Lowe, M. J. S.; Canvley, P.

    2006-01-01

    The prototype of a guided ultrasonic wave array for the structural integrity monitoring of large, plate-like structures has been designed, built, and tested. The development of suitably small transducers for the excitation and measurement of the first antisymmetric Lamb wave mode A(0) is described. The array design consists of a ring of 32 transducers, permanently bonded to the structure with a protective membrane, in a compact housing with the necessary multiplexing electronics. Using a phas...

  20. Real-Time Physiological and Psycho-Physiological Status Monitoring (Suivi en Temps reel de l’Etat Physiologique et Psycho-Physiologique)

    Science.gov (United States)

    2010-07-01

    implemented in only several sensors and parameters : ECG , heart rate, body temperature and actigraphy . Sensors are placed in the chest belt. 4.4.2...Characteristics of Real-Time Physiological Status Monitoring Systems 1-1 1.3 Sensors: Key Physiological Parameters to Monitor 1-2 1.4 Networks 1-2 1.5 Psycho...3-4-3 3-4.4.2 Questionnaires 3-4-3 3-4.4.3 Actigraphy 3-4-4 3-4.5 Conclusions 3-4-4 3-4.6 References 3-4-4 Chapter 3-5 – Monitoring of Heart

  1. FY15 Status Report: CIRFT Testing of Spent Nuclear Fuel Rods from Boiler Water Reactor Limerick

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jiang, Hao [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-06-01

    from 1.22 10⁵ to 4.70 10⁶, when the amplitude varied from 15.2 to 7.6 N·m. The measurements at the interrupts indicated a range of flexural rigidity from 30 to 50 Nm². The on-line monitoring revealed that the flexural rigidity was a little lower due to the high level of loading, from 25 to 42 Nm². Generally, no substantial change of rigidity was observed based on on-line monitoring during the cyclic fatigue testing process. Overall, the decreasing trend of lifetime with the increasing amplitude is well defined.

  2. Performance Studies of the Vibration Wire Monitor on the Test Stand with Low Energy Electron Beam

    Science.gov (United States)

    Okabe, Kota; Yoshimoto, Masahiro; Kinsho, Michikazu

    In the high intensity proton accelerator as the Japan Proton Accelerator Research Complex (J-PARC) accelerators, serious radiation and residual dose is induced by a small beam loss such a beam halo. Therefore, diagnostics of the beam halo formation is one of the most important issues to control the beam loss. For the beam halo monitor, the vibration wire monitor (VWM) has a potential for investigating the beam halo and weak beam scanning. The VWM has a wide dynamic range, high resolution and the VWM is not susceptible to secondary electrons and electric noises. We have studied the VWM features as a new beam-halo monitor on the test stand with low energy electron gun. The frequency shift of the irradiated vibration wire was confirmed about wire material and the electron beam profile measured by using the VWM was consistent with the results of the Faraday cup measurement. Also we calculated a temperature distribution on the vibration wire which is irradiated by the electron beam with the numerical simulation. The simulations have been fairly successful in reproducing the transient of the irradiated vibration wire frequency measured by test stand experiments. In this paper, we will report a result of performance evaluation for the VWM on the test stands and discuss the VWM for beam halo diagnostic

  3. Application of Pressure Pulse Test Analysis in CO2 Leakage Detection and Monitoring

    Science.gov (United States)

    Shakiba, M.; Hosseini, S. A.

    2015-12-01

    Over the past decade, numerous research and industrial projects have been devoted to investigate the feasibility and efficiency of carbon dioxide capture, storage, and utilization. Besides the studies over the characteristics of candidate formations for CO2 injection, much attention has been paid to answer the environmental concerns regarding the CO2 leak to overlying formations. To first detect and then track a possible CO2 leak, different techniques have been proposed in the literature; however, most of them examine only a small portion of the formation and have a low resolution for early leak detection. To further increase the extent of the investigation zone and to monitor a large section of the formation in more detail, multi-well testing techniques have received a significant attention. Pressure pulse testing is a multi-well test technique in which a pressure signal generated by periods of injection and shut-in from a pulser well is propagated inside the formation, and the corresponding response is recorded at the observer wells. The recorded pressure response is then analyzed to measure the rock and fluid properties and to monitor the possible changes over the time. In this research study, we have applied frequency methods as well as superposition principle to interpret the pressure pulse test data and monitor the changes in transmissibility and storativity of the formation between the well pairs. We have used synthetic reservoir models and numerical reservoir simulations to produce the pressure pulse test data. The analysis of the simulation results indicated that even a small amount of CO2 leak in the investigation zone can have a measurable effect on the calculated storativity and transmissibility factors. This can be of a great importance when an early leak detection is of interest. Moreover, when multiple wells are available in the formation, the distribution of the calculated parameters can visualize the extent of CO2 leak, which has a great

  4. Characterization of Material Response During Arc-Jet Testing with Optical Methods Status and Perspectives

    Science.gov (United States)

    Winter, Michael

    2012-01-01

    The characterization of ablation and recession of heat shield materials during arc jet testing is an important step towards understanding the governing processes during these tests and therefore for a successful extrapolation of ground test data to flight. The behavior of ablative heat shield materials in a ground-based arc jet facility is usually monitored through measurement of temperature distributions (across the surface and in-depth), and through measurement of the final surface recession. These measurements are then used to calibrate/validate materials thermal response codes, which have mathematical models with reasonably good fidelity to the physics and chemistry of ablation, and codes thus calibrated are used for predicting material behavior in flight environments. However, these thermal measurements only indirectly characterize the pyrolysis processes within an ablative material pyrolysis is the main effect during ablation. Quantification of pyrolysis chemistry would therefore provide more definitive and useful data for validation of the material response codes. Information of the chemical products of ablation, to various levels of detail, can be obtained using optical methods. Suitable optical methods to measure the shape and composition of these layers (with emphasis on the blowing layer) during arc jet testing are: 1) optical emission spectroscopy (OES) 2) filtered imaging 3) laser induced fluorescence (LIF) and 4) absorption spectroscopy. Several attempts have been made to optically measure the material response of ablative materials during arc-jet testing. Most recently, NH and OH have been identified in the boundary layer of a PICA ablator. These species are suitable candidates for a detection through PLIF which would enable a spatially-resolved characterization of the blowing layer in terms of both its shape and composition. The recent emission spectroscopy data will be presented and future experiments for a qualitative and quantitative

  5. Tracking working status of HIV/AIDS-trained service providers by means of a training information monitoring system in Ethiopia

    Directory of Open Access Journals (Sweden)

    Nadew Mesrak

    2009-04-01

    Full Text Available Abstract Background The Federal Ministry of Health of Ethiopia is implementing an ambitious and rapid scale-up of health care services for the prevention, care and treatment of HIV/AIDS in public facilities. With support from the United States President's Emergency Plan for AIDS Relief, 38 830 service providers were trained, from early 2005 until December 2007, in HIV-related topics. Anecdotal evidence suggested high attrition rates of providers, but reliable quantitative data have been limited. Methods With that funding, Jhpiego supports a Training Information Monitoring System, which stores training information for all HIV/AIDS training events supported by the same funding source. Data forms were developed to capture information on providers' working status and were given to eight partners who collected data during routine site visits on individual providers about working status; if not working at the facility, date of and reason for leaving; and source of information. Results Data were collected on 1744 providers (59% males in 53 hospitals and 45 health centres in 10 regional and administrative states. The project found that 32.6% of the providers were no longer at the site, 57.6% are still working on HIV/AIDS services at the same facility where they were trained and 10.4% are at the facility, but not providing HIV/AIDS services. Of the providers not at the facility, the two largest groups were those who had left for further study (27.6% and those who had gone to another public facility (17.6%. Of all physicians trained, 49.2% had left the facility. Regional and cadre variation was found, for example Gambella had the highest percent of providers no longer at the site (53.7% while Harari had the highest percentage of providers still working on HIV/AIDS (71.6%. Conclusion Overall, the project found that the information in the Training Information Monitoring System can be used to track the working status of trained providers. Data generated from

  6. FY 2016 Status Report: CIRFT Testing Data Analyses and Updated Curvature Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-08-01

    ) (10 tests) SNF samples. These CIRFT tests were completed in FY14 and FY15. Specifically, the data sets obtained from measurement and monitoring were processed and analyzed. The fatigue life of rods has been characterized in terms of moment, curvature, and equivalent stress and strain..

  7. FY 2016 Status Report: CIRFT Testing Data Analyses and Updated Curvature Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-08-01

    tests) SNF samples. These CIRFT tests were completed in FY14 and FY15. Specifically, the data sets obtained from measurement and monitoring were processed and analyzed. The fatigue life of rods has been characterized in terms of moment, curvature, and equivalent stress and strain..

  8. Status and future plans of the Drones for Aerodynamic and Structural Testing (DAST) program. [Aeroelastic Research Wing (ARW)

    Science.gov (United States)

    Murrow, H. N.

    1981-01-01

    Results from flight tests of the ARW-1 research wing are presented. Preliminary loads data and experiences with the active control system for flutter suppression are included along with comparative results of test and prediction for the flutter boundary of the supercritical research wing and on performance of the flutter suppression system. The status of the ARW-2 research wing is given.

  9. Production and test of monitored drift tubes for the muon spectrometer of the ATLAS experiment

    CERN Document Server

    Aprile, A; Campagna, A; Capua, M; Cuce, D; Ferraro, E; Lamanna, E; La Rotonda, L; Meoni, E; Pellegrino, F; Romano, V; Schioppa, M; Susinno, G; Turco, R P; Vena, R

    2002-01-01

    ATLAS is one of the two general-purpose experiments being built for the Large Hadron Collider at CERN. Its muon spectrometer consists of very high-precision chambers made of drift tubes. Up to now, more than 5000 monitored drift tubes (MDTs) have been constructed and tested at the University of Calabria, Italy, for ATLAS barrel system chambers of the muon detector. This paper reports the critical MDT assembly techniques in detail, including the automatic electronics system and data acquisition system. The extensive tests performed on individual drift tubes and the first results and experience are also reported. (5 refs).

  10. Propulsion Health Monitoring of a Turbine Engine Disk Using Spin Test Data

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark R.; Oza, Nikunj; Matthews, Bryan; Baaklini, George Y.

    2010-01-01

    This paper considers data collected from an experimental study using high frequency capacitive sensor technology to capture blade tip clearance and tip timing measurements in a rotating turbine engine-like-disk-to predict the disk faults and assess its structural integrity. The experimental results collected at a range of rotational speeds from tests conducted at the NASA Glenn Research Center s Rotordynamics Laboratory are evaluated using multiple data-driven anomaly detection techniques to identify abnormalities in the disk. Further, this study presents a select evaluation of an online health monitoring scheme of a rotating disk using high caliber sensors and test the capability of the in-house spin system.

  11. Air Monitoring Network at Tonopah Test Range: Network Description and Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Tappen; George Nikolich; Ken Giles; David Shafer; Tammy Kluesner

    2010-05-18

    During the period April to June 2008, at the behest of the U.S. Department of Energy (DOE) National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Sub-Project. The TTR is located within the boundaries of the Nevada Test and Training Range (NTTR) near the northern edge, and covers an area of approximately 725.20 km2 (179,200 acres). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is wind transport of radiological contaminants from one of the three Soil Sub-Project Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.

  12. First test results of a high-speed beam conditions monitor for the ATLAS experiment

    CERN Document Server

    Pernegger, Heinz

    2004-01-01

    The paper presents the design and first test results of the high- speed beam conditions monitor (BCM) for the ATLAS experiment at the large hadron collider (LHC). The goal of the BCM is to monitor instantaneous rates of collision and background and detect signs of beam instabilities. The detector is based on polycrystalline chemical-vapor-deposition (pCVD) diamond as active sensor material. We have chosen this detector material for its proven radiation hardness and fast signal properties. For the readout of the diamonds we developed front-end readout electronics based on high-bandwidth RF amplifiers. The signal response of the amplifier has been optimized for the ionization current signal of pCVD diamond in order to achieve a signal risetime of test results which were obtained on prototype assemblies in source tests and test beam. The obtained results demonstrate the feasibility of such a detector system for the ATLAS BCM. The tests yield BCM signals w...

  13. Air Monitoring Network at Tonopah Test Range: Network Description, Capabilities, and Analytical Results

    Energy Technology Data Exchange (ETDEWEB)

    Hartwell, William T.; Daniels, Jeffrey; Nikolich, George; Shadel, Craig; Giles, Ken; Karr, Lynn; Kluesner, Tammy

    2012-01-01

    During the period April to June 2008, at the behest of the Department of Energy (DOE), National Nuclear Security Administration, Nevada Site Office (NNSA/NSO); the Desert Research Institute (DRI) constructed and deployed two portable environmental monitoring stations at the Tonopah Test Range (TTR) as part of the Environmental Restoration Project Soils Activity. DRI has operated these stations since that time. A third station was deployed in the period May to September 2011. The TTR is located within the northwest corner of the Nevada Test and Training Range (NTTR), and covers an area of approximately 725.20 km2 (280 mi2). The primary objective of the monitoring stations is to evaluate whether and under what conditions there is wind transport of radiological contaminants from Soils Corrective Action Units (CAUs) associated with Operation Roller Coaster on TTR. Operation Roller Coaster was a series of tests, conducted in 1963, designed to examine the stability and dispersal of plutonium in storage and transportation accidents. These tests did not result in any nuclear explosive yield. However, the tests did result in the dispersal of plutonium and contamination of surface soils in the surrounding area.

  14. TREADMILL AND CYCLE ERGOMETER TESTS ARE INTERCHANGEABLE TO MONITOR TRIATHLETES ANNUAL TRAINING

    Directory of Open Access Journals (Sweden)

    Fabien A. Basset

    2003-09-01

    Full Text Available The purpose of this study was to verify the use of a single test to obtain annual training guidelines applicable to multiple modes of training. Eight triathletes (4 females, 4 males were tested 3 times during their training year (Phase I; Phase II; Phase III on a treadmill and cycle ergometer. Cardio-respiratory variables were calculated at standardized percentages of maximal oxygen uptake (VO2max; 50-100%. VO2max differences between tests reached 6% in every testing session (p 0.01. VO2max was stable for both tests throughout the season. The ANOVA (3 phases x 2 tests x 6 intensities demonstrated that there was a significant difference for heart rate (HRs; p 0.05 between tests in Phase I only. However, the nonparametric sign test did not show any significant differences in any phase. These results demonstrated that triathletes could use the relationship between HR and % VO2max collected during a treadmill or a cycle ergometer test to obtain interchangeable reference HRs for monitoring their running and cycling training bouts in high volume and/or high intensity phases of their training year.

  15. Measured Test-Driven Development: Using Measures to Monitor and Control the Unit Development

    Directory of Open Access Journals (Sweden)

    Y. Dubinsky

    2007-01-01

    Full Text Available We analyze Test Driven Development (TDD from cognitive and social perspectives. Based on our analysis, we suggest a technique for controlling and monitoring the TDD process by examining measures that relate to the size and complexity of both code and tests. We call this approach Measured TDD. The motivation for TDD arose from practitioners' tendency to rush into code production, skipping the required testing needed to manufacture quality products. The motivation for Measured TDD is based on difficulties encountered by practitioners in applying TDD. Specifically, with the need to frequently refactor the unit, after every few test and code steps have been performed. We found that the suggested technique enables developers to gain better control over the development process.

  16. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C.; Bresson, J.; Chiffot, T.; Guillot, L. [Centre d`Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L`Energie Atomique, Tille (France)

    1997-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  17. 3D Case Studies of Monitoring Dynamic Structural Tests using Long Exposure Imagery

    Science.gov (United States)

    McCarthy, D. M. J.; Chandler, J. H.; Palmeri, A.

    2014-06-01

    Structural health monitoring uses non-destructive testing programmes to detect long-term degradation phenomena in civil engineering structures. Structural testing may also be carried out to assess a structure's integrity following a potentially damaging event. Such investigations are increasingly carried out with vibration techniques, in which the structural response to artificial or natural excitations is recorded and analysed from a number of monitoring locations. Photogrammetry is of particular interest here since a very high number of monitoring locations can be measured using just a few images. To achieve the necessary imaging frequency to capture the vibration, it has been necessary to reduce the image resolution at the cost of spatial measurement accuracy. Even specialist sensors are limited by a compromise between sensor resolution and imaging frequency. To alleviate this compromise, a different approach has been developed and is described in this paper. Instead of using high-speed imaging to capture the instantaneous position at each epoch, long-exposure images are instead used, in which the localised image of the object becomes blurred. The approach has been extended to create 3D displacement vectors for each target point via multiple camera locations, which allows the simultaneous detection of transverse and torsional mode shapes. The proposed approach is frequency invariant allowing monitoring of higher modal frequencies irrespective of a sampling frequency. Since there is no requirement for imaging frequency, a higher image resolution is possible for the most accurate spatial measurement. The results of a small scale laboratory test using off-the-shelf consumer cameras are demonstrated. A larger experiment also demonstrates the scalability of the approach.

  18. 2009 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-09-01

    This report presents the 2009 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of CNTA was transferred from the DOE Office of Environmental Management to LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site from October 2008 through December 2009. It also represents the first year of the enhanced monitoring network and begins the new 5-year proof-of-concept monitoring period that is intended to validate the compliance boundary

  19. 2010 Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-02-01

    This report presents the 2010 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Subsurface Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of CNTA was transferred from the DOE Office of Environmental Management to LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order entered into by DOE, the U.S. Department of Defense, and the State of Nevada. The corrective action strategy for the site includes proof-of-concept monitoring in support of site closure. This report summarizes investigation activities associated with CAU 443 that were conducted at the site from December 2009 through December 2010. It also represents the second year of the enhanced monitoring network and the 5-year proof-of-concept monitoring period that is intended to validate the compliance boundary

  20. The Health Monitoring Method of Concrete Dams Based on Ambient Vibration Testing and Kernel Principle Analysis

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2015-01-01

    Full Text Available The ambient vibration testing (AVT measurement of concrete dams on full-scale can show the practical dynamic properties of structure in the operation state. For most current researches, the AVT data is generally analyzed to identify the structural vibration characteristics, that is, modal parameters. The identified modal parameters, which can provide the global damage information or the damage location information of structure, can be used as the basis of structure health monitoring. Therefore, in this paper, the health monitoring method of concrete dams based on the AVT is studied. The kernel principle analysis (KPCA based method is adopted to eliminate the effect of environmental variables and monitor the health of dam under varying environments. By taking full advantage of the AVT data obtained from vibration observation system of dam, the identification capabilities and the warning capabilities of structural damage can be improved. With the simulated AVT data of the numerical model of a concrete gravity dam and the measured AVT data of a practical engineering, the performance of the dam health monitoring method proposed in this paper is verified.

  1. Pendulum support of the W7-X plasma vessel: Design, tests, manufacturing, assembly, critical aspects, status

    Energy Technology Data Exchange (ETDEWEB)

    Missal, B., E-mail: bernd.missal@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Leher, F.; Schiller, T. [MAN Diesel and Turbo SE, Werftstraße 17, 94469 Deggendorf (Germany); Friedrich, P. [Universität Rostock, FB Maschinenbau und Schiffstechnik, Albert-Einsteins-Straße 2, 18051 Rostock (Germany); Capriccioli, A. [ENEA Frascati, Fusion Technology Unit, Frascati (Italy)

    2014-10-15

    Highlights: • Plasma vessel support has to allow vertical adjustment and horizontal passive movement. • Planar sliding tables with PTFE do not fulfill all requirements. • Pendulums can fulfill all requirements. • Geometry and material of spherical bearings had to be optimized in calculations and tests. • Optimized pendulums were manufactured and assembled. - Abstract: The superconducting helical advanced stellarator Wendelstein 7-X (W7-X) is under construction at the Max-Planck-Institut für Plasmaphysik (IPP) in Greifswald, Germany. The three dimensional shape of plasma will be generated by 50 non-planar magnetic coils. The plasma vessel geometry follows exactly this three dimensional shape of plasma. To ensure the superconductivity of coils a cryo vacuum has to be generated. Therefore the coils and their support structure are enclosed within the outer vessel. Plasma vessel, coil structures and outer vessel have to be supported separately. This paper will describe the vertical supports of plasma vessel which have to fulfill two special requirements, vertical adjustability and horizontal mobility. These two tasks will be carried out by plasma vessel supports (PVS) with hydraulic cylinders, special sliding tables during assembly and pendulum supports during operating phase. The paper will give an overview of design, calculation, tests, fabrication, assembly, critical aspects and status of PVS.

  2. Hyperoxia Improves Hemodynamic Status During Head-up Tilt Testing in Healthy Volunteers: A Randomized Study.

    Science.gov (United States)

    Fromonot, Julien; Chaumet, Guillaume; Gavarry, Olivier; Rostain, Jean-Claude; Lucciano, Michel; Joulia, Fabrice; Brignole, Michele; Deharo, Jean-Claude; Guieu, Regis; Boussuges, Alain

    2016-02-01

    Head-up tilt test is useful for exploring neurally mediated syncope. Adenosine is an ATP derivative implicated in cardiovascular disturbances that occur during head-up tilt test. The aim of the present study was to investigate the impact of hyperoxia on adenosine plasma level and on hemodynamic changes induced by head-up tilt testing.Seventeen healthy male volunteers (mean age 35 ± 11 years) were included in the study. The experiment consisted of 2 head-up tilt tests, 1 session with subjects breathing, through a mask, medical air (FiO2 = 21%) and 1 session with administration of pure oxygen (FiO2 = 100%) in double-blind manner. Investigations included continuous monitoring of hemodynamic data and measurement of plasma adenosine levels.No presyncope or syncope was found in 15 of the 17 volunteers. In these subjects, a slight decrease in systolic blood pressure was recorded during orthostatic stress performed under medical air exposure. In contrast, hyperoxia led to increased systolic blood pressure during orthostatic stress when compared with medical air. Furthermore, mean adenosine plasma levels decreased during hyperoxic exposure before (0.31 ± 0.08 μM) and during head-up tilt test (0.33 ± 0.09 μM) when compared with baseline (0.6 ± 0.1 μM). Adenosine plasma level was unchanged during medical air exposure at rest (0.6 ± 0.1 μM), and slightly decreased during orthostatic stress. In 2 volunteers, the head-up tilt test induced a loss of consciousness when breathing air. In these subjects, adenosine plasma level increased during orthostatic stress. In contrast, during hyperoxic exposure, the head-up tilt test did not induce presyncope or syncope. In these 2 volunteers, biological study demonstrated a decrease in adenosine plasma level at both baseline and during orthostatic stress for hyperoxic exposure compared with medical air.These results suggest that hyperoxia was able to increase blood pressure during head-up tilt

  3. Turbine Engine Disk Rotor Health Monitoring Assessment Using Spin Tests Data

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark; Baalini, George; Bodis, James R.

    2012-01-01

    Detecting rotating engine component malfunctions and structural anomalies is increasingly becoming a crucial key feature that will help boost safety and lower maintenance cost. However, achievement of such technology, which can be referred to as a health monitoring remains somewhat challenging to implement. This is mostly due to presence of scattered loading conditions, crack sizes, component geometry and material properties that hinders the simplicity of imposing such application. Different approaches are being considered to assist in developing other means of health monitoring or nondestructive techniques to detect hidden flaws and mini cracks before any catastrophic events occur. These methods extend further to assess material discontinuities and other defects that have matured to the level where a failure is very likely. This paper is focused on presenting data obtained from spin test experiments of a turbine engine like rotor disk and their correlation to the development of a structural health monitoring and fault detection system. The data collected includes blade tip clearance, blade tip timing measurements and shaft displacements. The experimental results are collected at rotational speeds up to 10,000 Rpm and tests are conducted at the NASA Glenn Research Center s Rotordynamics Laboratory via a high precision spin system. Additionally, this study offers a closer glance at a selective online evaluation of a rotating disk using advanced capacitive, microwave and eddy current sensor technology.

  4. Phase II: Field Detector Development For Undeclared/Declared Nuclear Testing For Treaty Verfiation Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kriz, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hunter, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-02

    Radioactive xenon isotopes are a critical part of the Comprehensive Nuclear Test Ban Treaty (CTBT) for the detection or confirmation of nuclear weapons tests as well as on-site treaty verification monitoring. On-site monitoring is not currently conducted because there are no commercially available small/robust field detector devices to measure the radioactive xenon isotopes. Xenon is an ideal signature to detect clandestine nuclear events since they are difficult to contain and can diffuse and migrate through soils due to their inert nature. There are four key radioxenon isotopes used in monitoring: 135Xe (9 hour half-life), 133mXe (2 day half-life), 133Xe (5 day half-life) and 131mXe (12 day half-life) that decay through beta emission and gamma emission. Savannah River National Laboratory (SRNL) is a leader in the field of gas collections and has developed highly selective molecular sieves that allow for the collection of xenon gas directly from air. Phase I assessed the development of a small, robust beta-gamma coincidence counting system, that combines collection and in situ detection methodologies. Phase II of the project began development of the custom electronics enabling 2D beta-gamma coincidence analysis in a field portable system. This will be a significant advancement for field detection/quantification of short-lived xenon isotopes that would not survive transport time for laboratory analysis.

  5. Noninvasive cerebral blood oxygenation monitoring: clinical test of multiwavelength optoacoustic system

    Science.gov (United States)

    Petrov, Y. Y.; Prough, D. S.; Petrova, I.; Patrikeev, I. A.; Cicenaite, I.; Esenaliev, R. O.

    2007-02-01

    Continuous monitoring of cerebral blood oxygenation is critically important for treatment of patients with life-threatening conditions like severe brain injury or during cardiac surgery. We designed and built a novel multiwavelength optoacoustic system for noninvasive, continuous, and accurate monitoring of cerebral blood oxygenation. We use an Optical Parametric Oscillator as a light source. We successfully tested the system in vitro as well as in vivo in large animals (sheep) through thick tissues overlying blood vessels which drain venous blood out of the brain (e.g., superior sagittal sinus or jugular vein). Here we present the results of clinical tests of the system for continuous noninvasive cerebral blood oxygenation monitoring in the internal jugular vein of healthy volunteers. We applied our custom-built optoacoustic probe (which incorporated a wide-band acoustic transducer and an optical fiber) to the neck area overlying the internal jugular vein. We performed measurements with volunteers at 18 wavelengths in the near-infrared spectral range. Despite a thick layer of overlying connective tissue and low energy used in the experiments, we recorded signals with high signal-to-noise ratios for all volunteers. We found that the temporal (independent of signal amplitude) parameters of recorded profiles for different levels of blood oxygenation correlated well with the spectrum of effective attenuation coefficients of blood.

  6. Turbine engine rotor health monitoring evaluation by means of finite element analyses and spin tests data

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark R.; Clem, Michelle; Baaklini, George Y.

    2014-04-01

    Generally, rotating engine components undergo high centrifugal loading environment which subject them to various types of failure initiation mechanisms. Health monitoring of these components is a necessity and is often challenging to implement. This is primarily due to numerous factors including the presence of scattered loading conditions, flaw sizes, component geometry and materials properties, all which hinder the simplicity of applying health monitoring applications. This paper represents a summary work of combined experimental and analytical modeling that included data collection from a spin test experiment of a rotor disk addressing the aforementioned durability issues. It further covers presentation of results obtained from a finite element modeling study to characterize the structural durability of a cracked rotor as it relates to the experimental findings. The experimental data include blade tip clearance, blade tip timing and shaft displacement measurements. The tests were conducted at the NASA Glenn Research Center's Rotordynamics Laboratory, a high precision spin rig. The results are evaluated and examined to determine their significance on the development of a health monitoring system to pre-predict cracks and other anomalies and to assist in initiating a supplemental physics based fault prediction analytical model.

  7. Turbine engine disk rotor health monitoring assessment using spin tests data

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark; Baaklini, George; Bodis, James R.

    2012-04-01

    Detecting rotating engine component malfunctions and structural anomalies is increasingly becoming a crucial key feature that will help boost safety and lower maintenance cost. However, achievement of such technology, which can be referred to as a health monitoring remains somewhat challenging to implement. This is mostly due to presence of scattered loading conditions, crack sizes, component geometry and material properties that hinders the simplicity of imposing such application. Different approaches are being considered to assist in developing other means of health monitoring or nondestructive techniques to detect hidden flaws and mini cracks before any catastrophic events occur. These methods extend further to assess material discontinuities and other defects that have matured to the level where a failure is very likely. This paper is focused on presenting data obtained from spin test experiments of a turbine engine like rotor disk and their correlation to the development of a structural health monitoring and fault detection system. The data collected includes blade tip clearance, blade tip timing measurements and shaft displacements. The experimental results are collected at rotational speeds up to 10,000 Rpm and tests are conducted at the NASA Glenn Research Center's Rotordynamics Laboratory via a high precision spin system. Additionally, this study offers a closer glance at a selective online evaluation of a rotating disk using advanced capacitive, microwave and eddy current sensor technology.

  8. Monitoring dental-unit-water-line output water by current in-office test kits.

    Science.gov (United States)

    Lal, Sham; Singhrao, Sim K; Bricknell, Matt; Pearce, Mark; Morton, L H Glyn; Ahmed, Waqar; Crean, St John

    2014-08-01

    The importance of monitoring contamination levels in the output water of dental-unit-water-lines (DUWLs) is essential as they are prone to developing biofilms that may contaminate water that is used to treat patients, with opportunistic pathogens such as species of Legionella, Pseudomonas and others. Dentists and practice staff are also at risk of being infected by means of cross-infection due to aerosols generated from DUWL water. The unit of measurement for the microbial contamination of water by aerobic mesophilic heterotrophic bacteria is the colony-forming unit per millilitre (cfu/ml) of water. The UK has its own guidelines set by the Department of Health for water discharged from DUWL to be between 100 and 200 cfu/ml of water. The benchmark or accepted standard laboratory test is by microbiological culture on R2A agar plates. However, this is costly and not convenient for routine testing in dental practices. A number of commercial indicator tests are used in dental surgeries, but they were not developed for the dental market and serve only to indicate gross levels of contamination when used outside of the manufacturer's recommended incubation period. The aim of this article is to briefly review the universal problem of DUWL contamination with microbial biofilms and to update dental professionals on the availability of currently available commercial in-office monitoring systems for aerobic mesophilic heterotrophic bacteria and to discuss their limitations for testing water samples in assuring compliance with recommended guidelines.

  9. Redesign of genetically encoded biosensors for monitoring mitochondrial redox status in a broad range of model eukaryotes.

    Science.gov (United States)

    Albrecht, Simone C; Sobotta, Mirko C; Bausewein, Daniela; Aller, Isabel; Hell, Rüdiger; Dick, Tobias P; Meyer, Andreas J

    2014-03-01

    The development of genetically encoded redox biosensors has paved the way toward chemically specific, quantitative, dynamic, and compartment-specific redox measurements in cells and organisms. In particular, redox-sensitive green fluorescent proteins (roGFPs) have attracted major interest as tools to monitor biological redox changes in real time and in vivo. Most recently, the engineering of a redox relay that combines glutaredoxin (Grx) with roGFP2 as a translational fusion (Grx1-roGFP2) led to a biosensor for the glutathione redox potential (EGSH ). The expression of this probe in mitochondria is of particular interest as mitochondria are the major source of oxidants, and their redox status is closely connected to cell fate decisions. While Grx1-roGFP2 can be expressed in mammalian mitochondria, it fails to enter mitochondria in various nonmammalian model organisms. Here we report that inversion of domain order from Grx1-roGFP2 to roGFP2-Grx1 yields a biosensor with perfect mitochondrial targeting while fully maintaining its biosensor capabilities. The redesigned probe thus allows extending in vivo observations of mitochondrial redox homeostasis to important nonmammalian model organisms, particularly plants and insects.

  10. Transport infrastructure monitoring: Testing of the NIODIM optical displacement monitoring system at the Sihlhochstrasse bridge in Zürich, Switzerland.

    Science.gov (United States)

    Hagene, J. K.

    2012-04-01

    A gound based optical displacement monitoring system, "NIODIM", is being developed by Norsk Elektro Optikk in the framework of the activities of the European project "Integrated System for Transport Infrastructure surveillance and Monitoring by Electromagnetic Sensing" (ISTIMES), funded in the 7th Framework Programme (FP7/2007-2013). The optical displacement monitoring system has now participated in two real life field campaigns one in Switzerland and one in Italy. The test campaign in Switzerland during a week in May 2011 will be presented below. The NIODIM system is based on a camera part mounted on firm ground and this camera is imaging a reference point, normally a light emitting diode (LED) which is supposed to be mounted on an object susceptible to move or oscillate. A microprocessor based unit is processing the acquired images and is calculating the displacement. The Sihlhochstrasse bridge is placed on concrete pillars in the river Sihl in Zürich and the motorway is one of the entrance routes to the city. A site visit had been performed in advance and it had been decided to mount the camera part as well as the processing unit at the lower part of the pillar above the relatively dry riverbed. The reference point in form of a light emitting diode was to be mounted below the bridge deck. However, due to practical access limitations it was not possible to place the reference LED in the middle between pillar pairs, but the LED had to be placed closer to next pair of the pillars downstream the river thus increasing the distance and possibly reducing the potential displacement. A lower signal due to reduced sensitivity (length) and due to lower deflection (better support from the pillar) had to be expected. The system would be powered by a generator placed on the riverbed. Arriving at the river front the fist day of the field trials was a surprise to most the campaign members. Due to heavy rain the week before, and in particular up in the mountains, the water

  11. A Novel Computerized Test for Detecting and Monitoring Visual Attentional Deficits and Delirium in the ICU.

    Science.gov (United States)

    Green, Cameron; Hendry, Kirsty; Wilson, Elizabeth S; Walsh, Timothy; Allerhand, Mike; MacLullich, Alasdair M J; Tieges, Zoë

    2017-07-01

    Delirium in the ICU is associated with poor outcomes but is under-detected. Here we evaluated performance of a novel, graded test for objectively detecting inattention in delirium, implemented on a custom-built computerized device (Edinburgh Delirium Test Box-ICU). A pilot study was conducted, followed by a prospective case-control study. Royal Infirmary of Edinburgh General ICU. A pilot study was conducted in an opportunistic sample of 20 patients. This was followed by a validation study in 30 selected patients with and without delirium (median age, 63 yr; range, 23-84) who were assessed with the Edinburgh Delirium Test Box-ICU on up to 5 separate days. Presence of delirium was assessed using the Confusion Assessment Method for the ICU. The Edinburgh Delirium Test Box-ICU involves a behavioral assessment and a computerized test of attention, requiring patients to count slowly presented lights. Thirty patients were assessed a total of 79 times (n = 31, 23, 15, 8, and 2 for subsequent assessments; 38% delirious). Edinburgh Delirium Test Box-ICU scores (range, 0-11) were lower for patients with delirium than those without at the first (median, 0 vs 9.5), second (median, 3.5 vs 9), and third (median, 0 vs 10.5) assessments (all p Delirium Test Box-ICU score less than or equal to 5 was 100% sensitive and 92% specific to delirium across assessments. Longitudinally, participants' Edinburgh Delirium Test Box-ICU performance was associated with delirium status. These findings suggest that the Edinburgh Delirium Test Box-ICU has diagnostic utility in detecting ICU delirium in patients with Richmond Agitation and Sedation Scale Score greater than -3. The Edinburgh Delirium Test Box-ICU has potential additional value in longitudinally tracking attentional deficits because it provides a range of scores and is sensitive to change.

  12. Surface stabilization and revegetation test plots. Fiscal year 1993 status report

    Energy Technology Data Exchange (ETDEWEB)

    Sackschewsky, M.R.; Kemp, C.J.; Hayward, W.M.

    1993-09-01

    Westinghouse Hanford Company Decommissioning and Decontamination Engineering Group and Environmental Technology and Assessment Groups are developing new technologies to improve revegetation techniques for interim stabilization control over underground waste sites within the Radiation Area Remedial Action Program. Successful revegetation is an integral aspect of waste isolation strategy. Unfortunately, revegetation can be very difficult to achieve on the Hanford Site due to several factors: low annual precipitation, unpredictable timing of precipitation, low fertility of available soils, and coarse physical texture of soils covering waste sites. The tests in this report were performed during fiscal years 1992 and 1993 and include the use of two soil sealants in combination with bare soil and a soil/compost mixture and a comparison of a wheatgrass mixture and a native seed mixture. Hydroprobe access ports were placed in one-half of the test plots and moisture data was collected. Soil fertility and plant community characteristics were monitored during the two years of the test. During the first year all sites with compost provided additional fertility and retained greater amounts of soil moisture than noncomposted sites. The use of Enduraseal soil fixative provided greater soil moisture than the use of Aerospray-77 soil fixative. During the second year the use of compost and soil fixative`s had a lesser effect on soil moisture. During late summer periods all treatments had very similar soil moisture profiles. The use of compost greatly increased vegetative cover and soil fertility in comparison to sites that had no compost added. Testing of the seed mixtures found that Siberian wheatgrass and Sandberg`s bluegrass were the most dominant of the seeded species observed. All plots exhibited a dominant plant cover of volunteer cheatgrass. Biomass production was significantly greater on plots with compost than on the noncomposted plots.

  13. Development and testing of fiber beam monitors for the Muon g-2 experiment

    Science.gov (United States)

    Bjorkquist, Robin; Diamond, Edward; Martinez, Benjamin; Sblendorio, Alec; Gray, Frederick; Muon g-2 Collaboration

    2017-01-01

    The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion. Careful characterization of the stored muon beam will be crucial for the experiment, because several beam-related systematic effects must be taken into account. The fiber beam monitors will provide a direct measurement of the spatial, temporal and momentum distributions and betatron oscillations of the stored muon beam. These detectors were originally built by KEK for the previous Muon g-2 experiment at Brookhaven National Lab, but have been repaired and refurbished for the upcoming experiment, including new scintillating fibers and upgraded SiPM-based readout electronics. We present the final design of the fiber beam monitor system and the results of a recent beam test performed at SLAC.

  14. Comprehensive test ban treaty international monitoring system security threats and proposed security attributes

    Energy Technology Data Exchange (ETDEWEB)

    Draelos, T.J.; Craft, R.L.

    1996-03-01

    To monitor compliance with a Comprehensive Test Ban Treaty (CTBT), a sensing network, referred to as the International Monitoring System (IMS), is being deployed. Success of the IMS depends on both its ability to preform its function and the international community`s confidence in the system. To ensure these goals, steps must be taken to secure the system against attacks that would undermine it; however, it is not clear that consensus exists with respect to the security requirements that should be levied on the IMS design. In addition, CTBT has not clearly articulated what threats it wishes to address. This paper proposes four system-level threats that should drive IMS design considerations, identifies potential threat agents, and collects into one place the security requirements that have been suggested by various elements of the IMS community. For each such requirement, issues associated with the requirement are identified and rationale for the requirement is discussed.

  15. Lessons from five years of vegetation monitoring on the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B.

    1992-10-01

    In 1987 the US Department of Energy funded a formal, extensive monitoring program for the flora and fauna on the Nevada Test Site. The goal was to understand and record changes with time In the distribution and abundance of the plants and animals. The need to detect changes, rather than do a one-time characterization, required careful selection of parameters and the use of permanent plots to distinguish spatial from temporal variability. Repeated measurements of the same plots revealed errors and imprecision which required changes in training and data collection techniques. Interpretation of trends after several years suggested it will be important to monitor not only changes, but causes of change, such as soil moisture and herbivory. Finally, the requirement for records to be available over long periods of time poses problems of archiving and publication. This report consists of viewgraphs presenting the findings of the study.

  16. Proceedings of the Numerical Modeling for Underground Nuclear Test Monitoring Symposium

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.R.; Kamm, J.R. [eds.

    1993-11-01

    The purpose of the meeting was to discuss the state-of-the-art in numerical simulations of nuclear explosion phenomenology with applications to test ban monitoring. We focused on the uniqueness of model fits to data, the measurement and characterization of material response models, advanced modeling techniques, and applications of modeling to monitoring problems. The second goal of the symposium was to establish a dialogue between seismologists and explosion-source code calculators. The meeting was divided into five main sessions: explosion source phenomenology, material response modeling, numerical simulations, the seismic source, and phenomenology from near source to far field. We feel the symposium reached many of its goals. Individual papers submitted at the conference are indexed separately on the data base.

  17. The use of laboratory tests in diagnosis and monitoring of systemic lupus erythematosus.

    Science.gov (United States)

    Sinico, Renato Alberto; Bollini, Bruna; Sabadini, Ettore; Di Toma, Luca; Radice, Antonella

    2002-01-01

    Clinical immunology laboratories play an essential role in diagnosis and monitoring of systemic lupus erythematosus (SLE). To obtain the best results in terms of diagnostic performance and clinical usefulness, the following recommendations should be fulfilled: Indirect immunofluorescence on Hep-2 cells remains the method of choice for the detection of anti-nuclear antibodies (ANA). The sensitivity of ANA test for SLE is very high (almost 100%) but its specificity low since ANA can be present in a number of different clinical conditions and even in normal controls. Anti-dsDNA antibodies are highly specific for SLE and present in a high proportion of SLE patients (40-80%). The method of choice for anti-ds DNA is the Farr assay; however, the necessity of using radioactive material decreases its applicability. As an alternative, immunofluorescence on Crithidia Luciliae can be used in the diagnostic phase for its high specificity. It is not advisable to use ELISA, in the diagnostic phase, due to its low specificity. The quantitative determination of anti-dsDNA is useful for monitoring patients, in particular in the presence of nephritis. For monitoring, a quantitative method should be used (Farr assay or ELISA). The detection of antibodies to extractable nuclear antigens (ENA) and to phospholipids (Lupus anticoagulant and anti-cardiolipin antibodies with a beta2 glycoprotein I-dependent method) are useful to identify subgroups of patients at risk for some clinical manifestations (i.e. anti-phospholipid syndrome). New assays (anti-C1q and anti-nucleosome antibodies) have been recently proposed for diagnosis (anti-nucleosome) and monitoring SLE patients (anti-C1q and anti-nucleosome antibodies), with promising results. Among biological parameters, urinary levels of monocyte chemoattranct protein 1 (MCP1) seem to be the most useful to monitor nephritis activity in lupus patients.

  18. Alternative (non-animal) methods for cosmetics testing: current status and future prospects-2010.

    Science.gov (United States)

    Adler, Sarah; Basketter, David; Creton, Stuart; Pelkonen, Olavi; van Benthem, Jan; Zuang, Valérie; Andersen, Klaus Ejner; Angers-Loustau, Alexandre; Aptula, Aynur; Bal-Price, Anna; Benfenati, Emilio; Bernauer, Ulrike; Bessems, Jos; Bois, Frederic Y; Boobis, Alan; Brandon, Esther; Bremer, Susanne; Broschard, Thomas; Casati, Silvia; Coecke, Sandra; Corvi, Raffaella; Cronin, Mark; Daston, George; Dekant, Wolfgang; Felter, Susan; Grignard, Elise; Gundert-Remy, Ursula; Heinonen, Tuula; Kimber, Ian; Kleinjans, Jos; Komulainen, Hannu; Kreiling, Reinhard; Kreysa, Joachim; Leite, Sofia Batista; Loizou, George; Maxwell, Gavin; Mazzatorta, Paolo; Munn, Sharon; Pfuhler, Stefan; Phrakonkham, Pascal; Piersma, Aldert; Poth, Albrecht; Prieto, Pilar; Repetto, Guillermo; Rogiers, Vera; Schoeters, Greet; Schwarz, Michael; Serafimova, Rositsa; Tähti, Hanna; Testai, Emanuela; van Delft, Joost; van Loveren, Henk; Vinken, Mathieu; Worth, Andrew; Zaldivar, José-Manuel

    2011-05-01

    The 7th amendment to the EU Cosmetics Directive prohibits to put animal-tested cosmetics on the market in Europe after 2013. In that context, the European Commission invited stakeholder bodies (industry, non-governmental organisations, EU Member States, and the Commission's Scientific Committee on Consumer Safety) to identify scientific experts in five toxicological areas, i.e. toxicokinetics, repeated dose toxicity, carcinogenicity, skin sensitisation, and reproductive toxicity for which the Directive foresees that the 2013 deadline could be further extended in case alternative and validated methods would not be available in time. The selected experts were asked to analyse the status and prospects of alternative methods and to provide a scientifically sound estimate of the time necessary to achieve full replacement of animal testing. In summary, the experts confirmed that it will take at least another 7-9 years for the replacement of the current in vivo animal tests used for the safety assessment of cosmetic ingredients for skin sensitisation. However, the experts were also of the opinion that alternative methods may be able to give hazard information, i.e. to differentiate between sensitisers and non-sensitisers, ahead of 2017. This would, however, not provide the complete picture of what is a safe exposure because the relative potency of a sensitiser would not be known. For toxicokinetics, the timeframe was 5-7 years to develop the models still lacking to predict lung absorption and renal/biliary excretion, and even longer to integrate the methods to fully replace the animal toxicokinetic models. For the systemic toxicological endpoints of repeated dose toxicity, carcinogenicity and reproductive toxicity, the time horizon for full replacement could not be estimated.

  19. Quality assurance for HIV point-of-care testing and treatment monitoring assays

    Directory of Open Access Journals (Sweden)

    Adrienne F.A. Meyers

    2016-10-01

    Full Text Available In 2015, UNAIDS launched the 90-90-90 targets aimed at increasing the number of peopleinfected with HIV to become aware of their status, access antiretroviral therapies and ultimatelybe virally suppressed. To achieve these goals, countries may need to scale up point-of-care (POC testing in addition to strengthening central laboratory services. While decentralisingtesting increases patient access to diagnostics, it presents many challenges with regard totraining and assuring the quality of tests and testing. To ensure synergies, the London Schoolof Hygiene & Tropical Medicine held a series of consultations with countries with an interestin quality assurance and their implementing partners, and agreed on an external qualityassessment (EQA programme to ensure reliable results so that the results lead to the bestpossible care for HIV patients. As a result of the consultations, EQA International wasestablished, bringing together EQA providers and implementers to develop a strategic planfor countries to establish national POC EQA programmes and to estimate the cost of setting upand maintaining the programme. With the dramatic increase in the number of proficiencytesting panels required for thousands of POC testing sites across Africa, it is important tofacilitate technology transfer from global EQA providers to a network of regional EQA centresin Africa for regional proficiency testing panel production. EQA International will continue toidentify robust and cost-effective EQA technologies for quality POC testing, integrating noveltechnologies to support sustainable country-owned EQA programmes in Africa.

  20. Development and Testing of Web GUI Application for the LHCb VELO Data Quality Monitoring System

    CERN Document Server

    Prykhodko, Pavlo; Collins, Paula

    A great interest of IT engineers at CERN is to simplify the access to the Data Quality Monitoring (DQM) applications that usually lay behind several layers of security firewalls. In order to make it simple and thus help to save time for the scientists who rely on this data, additional application for the Web had to be developed and tested. The goal of this thesis work was to develop such a Web DQM application for CERN. First, a Web Graphical User Interface (GUI) was developed. In parallel, an Apache server was installed and configured for testing. Moreover, software program called ROOTJS that processes and displays CERN data files on the Web was presented. Through this thesis project, new functionalities were developed to meet the requirements. Furthermore, the ROOTJS program was merged with the Web GUI application and series of tests were performed to showcase the capabilities of the application which was developed through this thesis work.

  1. Turbine rotor disk health monitoring assessment based on sensor technology and spin tests data.

    Science.gov (United States)

    Abdul-Aziz, Ali; Woike, Mark

    2013-01-01

    The paper focuses on presenting data obtained from spin test experiments of a turbine engine like rotor disk and assessing their correlation to the development of a structural health monitoring and fault detection system. The data were obtained under various operating conditions such as the rotor disk being artificially induced with and without a notch and rotated at a rotational speed of up to 10,000 rpm under balanced and imbalanced state. The data collected included blade tip clearance, blade tip timing measurements, and shaft displacements. Two different sensor technologies were employed in the testing: microwave and capacitive sensors, respectively. The experimental tests were conducted at the NASA Glenn Research Center's Rotordynamics Laboratory using a high precision spin system. Disk flaw observations and related assessments from the collected data for both sensors are reported and discussed.

  2. Testing the efficiency of temperate benthic biotic indices in assessing the ecological status of a tropical ecosystem.

    Science.gov (United States)

    Sivadas, Sanitha K; Nagesh, Rahul; Gupta, G V M; Gaonkar, Udaykumar; Mukherjee, Indranil; Ramteke, Darwin; Ingole, Baban S

    2016-05-15

    The objectives of the present study were to evaluate the ecological status of tropical coastal waters using the temperate benthic indices and examine the effect of seasonal variability on the performance of benthic indices. Macrobenthic samples were collected from northwest to southeast coast of India during 2003-2012 and we tested different univariate indices, ecological strategies, indicator species and multimetric indices. AMBI and multimetric indices performed satisfactorily in evaluating the ecological status. Seasonal variability on the biotic indices was observed during the southwest monsoon and fall intermonsoon period due to recruitment. Therefore, we recommended the non-monsoon period (January-May) as a suitable time of the year to use the indices for effective assessment of the Indian coastal waters. Results show that, the temperate benthic indices are efficient in assessing the tropical environmental status. However, complementary use of different indices is suggested for accurate assessment of the environmental status.

  3. Re-testing theories on the correlations of health status, life satisfaction and happiness

    OpenAIRE

    Paul Andrew Bourne; Chloe Morris; Denise Eldemire-Shearer

    2010-01-01

    Background : Empirical evidences have shown that happiness, life satisfaction and health status are strongly correlated with each other. In Jamaica, we continue to collect data on health status to guide policies and intervention programs, but are these wise? Aims: The current study aims to fill the gap in the literature by examining life satisfaction, health status, and happiness in order to ascertain whether they are equivalent concepts in Jamaica as well as the coverage of the estimates. Ma...

  4. Automated tests for diagnosing and monitoring cognitive impairment: a diagnostic accuracy review.

    Science.gov (United States)

    Aslam, Rabeea'h W; Bates, Vickie; Dundar, Yenal; Hounsome, Juliet; Richardson, Marty; Krishan, Ashma; Dickson, Rumona; Boland, Angela; Kotas, Eleanor; Fisher, Joanne; Sikdar, Sudip; Robinson, Louise

    2016-01-01

    BACKGROUND Cognitive impairment is a growing public health concern, and is one of the most distinctive characteristics of all dementias. The timely recognition of dementia syndromes can be beneficial, as some causes of dementia are treatable and are fully or partially reversible. Several automated cognitive assessment tools for assessing mild cognitive impairment (MCI) and early dementia are now available. Proponents of these tests cite as benefits the tests' repeatability and robustness and the saving of clinicians' time. However, the use of these tools to diagnose and/or monitor progressive cognitive impairment or response to treatment has not yet been evaluated. OBJECTIVES The aim of this review was to determine whether or not automated computerised tests could accurately identify patients with progressive cognitive impairment in MCI and dementia and, if so, to investigate their role in monitoring disease progression and/or response to treatment. DATA SOURCES Five electronic databases (MEDLINE, EMBASE, The Cochrane Library, ISI Web of Science and PsycINFO), plus ProQuest, were searched from 2005 to August 2015. The bibliographies of retrieved citations were also examined. Trial and research registers were searched for ongoing studies and reviews. A second search was run to identify individual test costs and acquisition costs for the various tools identified in the review. REVIEW METHODS Two reviewers independently screened all titles and abstracts to identify potentially relevant studies for inclusion in the review. Full-text copies were assessed independently by two reviewers. Data were extracted and assessed for risk of bias by one reviewer and independently checked for accuracy by a second. The results of the data extraction and quality assessment for each study are presented in structured tables and as a narrative summary. RESULTS The electronic searching of databases, including ProQuest, resulted in 13,542 unique citations. The titles and abstracts of these

  5. Automated tests for diagnosing and monitoring cognitive impairment: a diagnostic accuracy review.

    Science.gov (United States)

    Aslam, Rabeea'h W; Bates, Vickie; Dundar, Yenal; Hounsome, Juliet; Richardson, Marty; Krishan, Ashma; Dickson, Rumona; Boland, Angela; Kotas, Eleanor; Fisher, Joanne; Sikdar, Sudip; Robinson, Louise

    2016-10-01

    Cognitive impairment is a growing public health concern, and is one of the most distinctive characteristics of all dementias. The timely recognition of dementia syndromes can be beneficial, as some causes of dementia are treatable and are fully or partially reversible. Several automated cognitive assessment tools for assessing mild cognitive impairment (MCI) and early dementia are now available. Proponents of these tests cite as benefits the tests' repeatability and robustness and the saving of clinicians' time. However, the use of these tools to diagnose and/or monitor progressive cognitive impairment or response to treatment has not yet been evaluated. The aim of this review was to determine whether or not automated computerised tests could accurately identify patients with progressive cognitive impairment in MCI and dementia and, if so, to investigate their role in monitoring disease progression and/or response to treatment. Five electronic databases (MEDLINE, EMBASE, The Cochrane Library, ISI Web of Science and PsycINFO), plus ProQuest, were searched from 2005 to August 2015. The bibliographies of retrieved citations were also examined. Trial and research registers were searched for ongoing studies and reviews. A second search was run to identify individual test costs and acquisition costs for the various tools identified in the review. Two reviewers independently screened all titles and abstracts to identify potentially relevant studies for inclusion in the review. Full-text copies were assessed independently by two reviewers. Data were extracted and assessed for risk of bias by one reviewer and independently checked for accuracy by a second. The results of the data extraction and quality assessment for each study are presented in structured tables and as a narrative summary. The electronic searching of databases, including ProQuest, resulted in 13,542 unique citations. The titles and abstracts of these were screened and 399 articles were shortlisted for full

  6. Study and Test of a New Bundle-Structure Riser Stress Monitoring Sensor Based on FBG.

    Science.gov (United States)

    Xu, Jian; Yang, Dexing; Qin, Chuan; Jiang, Yajun; Sheng, Leixiang; Jia, Xiangyun; Bai, Yang; Shen, Xiaohong; Wang, Haiyan; Deng, Xin; Xu, Liangbin; Jiang, Shiquan

    2015-11-24

    To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG)-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the "HYSY-981" ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC) mechanical simulation results.

  7. Study and Test of a New Bundle-Structure Riser Stress Monitoring Sensor Based on FBG

    Directory of Open Access Journals (Sweden)

    Jian Xu

    2015-11-01

    Full Text Available To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the “HYSY-981” ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC mechanical simulation results.

  8. Tools for in service monitoring and testing of riser to prevent failure and extend service life

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Haakon; Bondevik, Jon Olav; Skjerve, Haavard; Tveit, Oeyvind [SeaFlex AS, Asker (Norway)

    2005-07-01

    Exploration and development of new oil and gas fields is heavily dependant on use of flexible pipes and many field developments would not have been possible without them. The number of flexible risers in service is constantly increasing since relatively few offshore projects have reached the estimated operational life and the operational lifetime of several fields in-service has been extended due to new and improved technology. Many risers have been in service over a large number of years. Some risers have been operated under demanding conditions such as severe dynamic loads, high pressure and temperatures. One may in some cases find that risers actually have shorter service life than estimated in the design phase due to the severe operational conditions. In order to extend the use of the riser, some risers may have to be modified and re-terminated and prepared for a new and less demanding application. In order to operate risers safely, it is important to re-assess the fatigue life in order to prevent potential riser failure. The operator should implement methods and tools for in-service monitoring and testing. This paper addresses efficient and reliable methods and tools for monitoring of critical operational parameters as well as in-service riser testing. A brief description of structural failure modes will also be given in order to understand how to interpret test results in view of potential failure modes. (author)

  9. Monitoring

    Science.gov (United States)

    ... a sample of how to record your hourly activities, eating and medication so you can see patterns based on your tests – ... a Diabetes Educator Diabetes Goal Tracker App Tip Sheets and Handouts AADE7 Self-Care ...

  10. NASA Prototype All Composite Tank Cryogenic Pressure Tests to Failure with Structural Health Monitoring

    Science.gov (United States)

    Werlink, Rudolph J.; Pena, Francisco

    2015-01-01

    This Paper will describe the results of pressurization to failure of 100 gallon composite tanks using liquid nitrogen. Advanced methods of health monitoring will be compared as will the experimental data to a finite element model. The testing is wholly under NASA including unique PZT (Lead Zirconate Titanate) based active vibration technology. Other technologies include fiber optics strain based systems including NASA AFRC technology, Acoustic Emission, Acellent smart sensor, this work is expected to lead to a practical in-Sutu system for composite tanks.

  11. Noncontact laser sensing technology for structural health monitoring and nondestructive testing (presentation video)

    Science.gov (United States)

    Sohn, Hoon

    2014-03-01

    Noncontact sensing techniques is gaining prominence for structural health monitoring (SHM) and nondestructive testing (NDT) due to (1) their noncontact and nonintrusive natures, (2) their spatial resolution much higher than conventional discrete sensors can achieve, (3) their less dependency on baseline data obtained from the pristine condition of a target structure (reference-free diagnosis), (4) cost and labor reduction in sensor installation and maintenance. In this talk, a suite of noncontact sensing techniques particularly based on laser technology will be presented for SHM and NDT of aircraft, wind turbine blades, high-speed trains, nuclear power plants, bridges, automobile manufacturing facilities and semiconductors.

  12. Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

    Science.gov (United States)

    Cojocariu, L. N.; Placinta, V. M.; Dumitru, L.

    2016-03-01

    A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

  13. On the possibility of using biological toxicity tests to monitor the work of wastewater treatment plants

    Directory of Open Access Journals (Sweden)

    Zorić Jelena

    2008-01-01

    Full Text Available The aim of this study was to ascertain the possibility of using biological toxicity tests to monitor influent and effluent wastewaters of wastewater treatment plants. The information obtained through these tests is used to prevent toxic pollutants from entering wastewater treatment plants and discharge of toxic pollutants into the recipient. Samples of wastewaters from the wastewater treatment plants of Kragujevac and Gornji Milanovac, as well as from the Lepenica and Despotovica Rivers immediately before and after the influx of wastewaters from the plants, were collected between October 2004 and June 2005. Used as the test organism in these tests was the zebrafish Brachydanio rerio Hamilton - Buchanon (Cyprinidae. The acute toxicity test of 96/h duration showed that the tested samples had a slight acutely toxic effect on B. rerio, except for the sample of influent wastewater into the Cvetojevac wastewater treatment plant, which had moderately acute toxicity, indicating that such water should be prevented from entering the system in order to eliminate its detrimental effect on the purification process.

  14. The Memory Alteration Test Discriminates between Cognitively Healthy Status, Mild Cognitive Impairment and Alzheimer's Disease

    Science.gov (United States)

    Custodio, Nilton; Lira, David; Herrera-Perez, Eder; Nuñez del Prado, Liza; Parodi, José; Guevara-Silva, Erik; Castro-Suarez, Sheila; Montesinos, Rosa; Cortijo, Patricia

    2014-01-01

    Background/Aims Dementia is a worldwide public health problem and there are several diagnostic tools for its assessment. The aim of this study was to evaluate the performance of the Memory Alteration Test (M@T) to discriminate between patients with early Alzheimer's disease (AD), patients with amnestic mild cognitive impairment (a-MCI), and subjects with a cognitively healthy status (CHS). Methods The discriminative validity was assessed in a sample of 90 patients with AD, 45 patients with a-MCI, and 180 subjects with CHS. Clinical, functional, and cognitive studies were independently performed in a blinded fashion and the gold standard diagnosis was established by consensus on the basis of these results. The test performance was assessed by means of a receiver operating characteristic curve analysis as area under the curve (AUC). Results M@T mean scores were 17.7 (SD = 5.7) in AD, 30.8 (SD = 2.3) in a-MCI, and 44.5 (SD = 3.1) in CHS. A cutoff score of 37 points had a sensitivity of 98.3% and a specificity of 97.8% to differentiate a-MCI from CHS (AUC = 0.999). A cutoff score of 27 points had a sensitivity of 100% and a specificity of 98.9% to differentiate mild AD from a-MCI and from CHS (AUC = 1.000). Conclusions The M@T had a high performance in the discrimination between early AD, a-MCI and CHS. PMID:25298775

  15. Performance of low-cost GNSS receiver for landslides monitoring: test and results

    Directory of Open Access Journals (Sweden)

    Alberto Cina

    2015-07-01

    Full Text Available Italy is deeply afflicted by geo-hydrological risk, where a predominant part of its area is under risk.Recently, advanced research and sensors have played an important role in realizing automatic systems for landslide monitoring and to alerting. The cost of these systems, considering all parts, limits their use and the cost of each sensor influences the investment. Geodetic global navigation satellite system (GNSS receivers, which are commonly used to realize these activities, are an appropriate example; however, their costs are quite high.The aim of this research was to test the actual performance of a mass-market GNSS receiver, with the purpose of verifying if such type of sensors can be used for landslide monitoring. In particular, the benefits due to the coupling between mass-market receivers and products offered by a network of GNSS permanent stations (e.g. Virtual RINEX have been investigated.To verify the capability of these sensors to detect a deformation, under the minimum deformation detectable point of view, a special slide was built, in order to conduct a dedicated test. The support was moved both in horizontal and vertical directions with high precision, with purpose to detect correctly a three-dimensional movement.Tests were carried out considering the dependence of some factors: the most important are the acquisition time and the distance from the GNSS reference station. Interesting is the use of virtual reference station based on GNSS network, as a reference station: the performance achieved using Virtual RINEX for the control of movements and deformations are analysed. The accuracy and precision of movement determination were evaluated and compared, for each test, considering the different factors. The tests and results are described in this contribution.

  16. Introduction of Pack Test for Participative Environmental Monitoring and Environmental Education for Sustainability in Malaysia

    Directory of Open Access Journals (Sweden)

    Muhammad Faiz Bin Abd Rahman

    2011-06-01

    Full Text Available Pack Test which provided by Kyoritsu Chemical-Check Lab. Corporation has been assumed as a professional easy-to-use onsite water quality checker. The aim of this study is to examine the possibility of application of Pack Test in Malaysia, and to assess the required matters during introduction processes. Two workshops were sampled to prove the potential function of Pack Test in environmental education and participative environmental monitoring. Two hours lecture of Universiti Teknologi Malaysia (UTM was facilitated as a workshop by author on September 23, 2010, and then the author has assisted a workshop in Putrajaya on October 9, 2010. Questionnaire forms were applied to test as if peoples feeling are positive or not towards Pack Test as preliminary research. Water quality parameters were simultaneously measured by Pack Test, such as, COD, NO3-, CI-, and NH4+ in UTM, pH and NO3- were measured in Putrajaya workshop, respectively. Participant�s feeling in the both workshops showed strong positive potential for Pack Test. Results of water qualities from UTM workshop had big variation in COD and NO3-. Considering the reason, the UTM workshop was conducted without proper support for both facilitator and participant. Participants were able to classify the water quality level in a short time. As for the Putrajaya workshop, with deep support and well skilled instruction by facilitator team, the data showed small variation i.e. good and consistent water quality result. It was obvious that Pack Test was always applicable to assess water environment and it was well functioned as user friendly easy-to-use water quality checker. Thereby the role of Pack Test was segregated from conventional standard methods. The participant�s feeling to Pack Test was strong positive for implementation and to improve public environmental awareness. Simultaneously, they were feeling that peoples can participate more effectively in water environment issues by Pack Test. It

  17. Thyroid gland status among population living around the semipalatinsk nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Zhumadilov, Z. [Semipalatinsk State Medical Academy (Kazakstan); Land, C.; Hartshorne, M. [and others

    2000-05-01

    From 1949-1962, regions of Kazakstan near the Semipalatinsk Nuclear Test Site (SNTS) were contaminated with high levels of radioactive fallout from atomic bomb tests carried out at the SNTS. The effective-dose is a principal criterion for the evaluation of the effect of radioactive fallout upon population. Thyroid disease prevalence may be ascertained, as a biomarker of radiation exposure and because it is of interest in itself. Some features from three studies of thyroid gland status among population living around SNTS will be reported. The first study is a case review of pathological findings of 7,271 patients from three regions adjacent to the SNTS, who were surgically treated during 1966-96; the second is a thyroid screening study of a cohort of 3000 village residents who were <20 years of age at the time of major fallout events in the Semipalatinsk region; the third is a complex molecular, morphological investigation and some approaches to rehabilitation of patients with thyroid abnormalities. Our first study revealed that there is a significant trend for the proportion of thyroid cancer to increase over time in the Semipalatinsk region of Kazakstan 20-29 years after onset of testing in 1949, which might be related to radiation exposure. There are many ethnic groups in this region. Our research among two main ethnic groups (native Kazakh and European extraction) detected that the initial level of thyroid abnormalities and thyroid cancer was higher among residents of European extraction. The total number of surgical cases increased among both ethnic groups over the years, but the numbers of cases with Hashimoto's thyroiditis and thyroid cancer increased dramatically among ethnic Kazakhs. Overall, papillary and follicular cancers predominated, but it should be noted the relatively high percentage of follicular cancers after 1982 in the Semipalatinsk region. The primary screening outcome measure was the prevaleance of thyroid nodules as determined by

  18. SisLeish: A multi-country standardized information system to monitor the status of Leishmaniasis in the Americas.

    Science.gov (United States)

    Maia-Elkhoury, Ana N S; O B Valadas, Samantha Y; Puppim-Buzanovsky, Lia; Rocha, Felipe; Sanchez-Vazquez, Manuel J

    2017-09-01

    In the Americas, leishmaniasis is endemic in 18 countries, and from 2001 through 2015, 17 countries reported 843,931 cases of cutaneous and mucocutaneous leishmaniasis, and 12 countries reported 52,176 cases of visceral leishmaniasis. A Regional Information System (SisLeish) was created in order to provide knowledge of the distribution and tendency of this disease to analyze and monitor the leishmaniasis status. This article analyses the performance and progress of SisLeish from 2012-2015. The performance of SisLeish was evaluated by country adhesion, data completeness and delay in entering the data, and also by the SWOT technique. Furthermore, we outlined the structure and modus operandi of the system and indicators utilized. In 2012, only 18% of the countries entered the data in SisLeish before the deadline, where 66.7% and 50% of the countries with autochthonous CL/ML and VL reported their cases to the system, respectively. Whereas in 2015, 59% of the countries reached the deadline, where 94.4% and 58.3% of the countries reported their CL/ML and VL data, respectively. Regarding data completeness, there was great progress for different variables since its launch, such as gender, which had an approximately 100% improvement from 2012 to 2015. The SWOT analysis of SisLeish showed 12 strengths, 11 opportunities, seven weaknesses and six threats. From 2012-2015 there has been an improvement in the adhesion, quality and data completeness, showing the effort of the majority of the countries to enhance their national database. The SWOT analysis demonstrated that strengths and opportunities exceed weaknesses and threats; however, it highlighted the system frailties and challenges that need to be addressed. Furthermore, it has stimulated several National Programs to advance their surveillance system. Therefore, SisLeish has become an essential tool to prioritize areas, assist in decision-making processes, and to guide surveillance and control actions.

  19. SisLeish: A multi-country standardized information system to monitor the status of Leishmaniasis in the Americas

    Science.gov (United States)

    Rocha, Felipe

    2017-01-01

    Background In the Americas, leishmaniasis is endemic in 18 countries, and from 2001 through 2015, 17 countries reported 843,931 cases of cutaneous and mucocutaneous leishmaniasis, and 12 countries reported 52,176 cases of visceral leishmaniasis. A Regional Information System (SisLeish) was created in order to provide knowledge of the distribution and tendency of this disease to analyze and monitor the leishmaniasis status. This article analyses the performance and progress of SisLeish from 2012–2015. Methodology The performance of SisLeish was evaluated by country adhesion, data completeness and delay in entering the data, and also by the SWOT technique. Furthermore, we outlined the structure and modus operandi of the system and indicators utilized. Results In 2012, only 18% of the countries entered the data in SisLeish before the deadline, where 66.7% and 50% of the countries with autochthonous CL/ML and VL reported their cases to the system, respectively. Whereas in 2015, 59% of the countries reached the deadline, where 94.4% and 58.3% of the countries reported their CL/ML and VL data, respectively. Regarding data completeness, there was great progress for different variables since its launch, such as gender, which had an approximately 100% improvement from 2012 to 2015. The SWOT analysis of SisLeish showed 12 strengths, 11 opportunities, seven weaknesses and six threats. Conclusions From 2012–2015 there has been an improvement in the adhesion, quality and data completeness, showing the effort of the majority of the countries to enhance their national database. The SWOT analysis demonstrated that strengths and opportunities exceed weaknesses and threats; however, it highlighted the system frailties and challenges that need to be addressed. Furthermore, it has stimulated several National Programs to advance their surveillance system. Therefore, SisLeish has become an essential tool to prioritize areas, assist in decision-making processes, and to guide

  20. The application of strength and power related field tests in older adults : criteria, current status and a future perspective

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Morat, Tobias; Folkersma, Marjanne; Zijlstra, Wiebren

    2015-01-01

    Leg muscle strength (LMS) and leg muscle power (LMP) are determinants of aspects of functional status and important parameters for measuring intervention effects in older adults. Field tests are often used for the evaluation of LMS and LMP in older persons. However, criteria important for the applic

  1. Parental Socioeconomic Status, Communication, and Children's Vocabulary Development: A Third-Generation Test of the Family Investment Model

    Science.gov (United States)

    Sohr-Preston, Sara L.; Scaramella, Laura V.; Martin, Monica J.; Neppl, Tricia K.; Ontai, Lenna; Conger, Rand

    2013-01-01

    This third-generation, longitudinal study evaluated a family investment perspective on family socioeconomic status (SES), parental investments in children, and child development. The theoretical framework was tested for first-generation parents (G1), their children (G2), and the children of the second generation (G3). G1 SES was expected to…

  2. The application of strength and power related field tests in older adults : criteria, current status and a future perspective

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Morat, Tobias; Folkersma, Marjanne; Zijlstra, Wiebren

    2015-01-01

    Leg muscle strength (LMS) and leg muscle power (LMP) are determinants of aspects of functional status and important parameters for measuring intervention effects in older adults. Field tests are often used for the evaluation of LMS and LMP in older persons. However, criteria important for the applic

  3. Socioeconomic Status Effects on Using the Naglieri Nonverbal Ability Test (NNAT) to Identify the Gifted/Talented

    Science.gov (United States)

    Carman, Carol A.; Taylor, Debra K.

    2010-01-01

    The Naglieri Nonverbal Ability Test (NNAT) is said to be a culturally neutral measure of ability that assesses both majority and minority students equally. Although research has examined the effects of ethnicity and gender on NNAT performance, little published research has examined the relationship between socioeconomic status (SES) and NNAT…

  4. Testing, Modeling, and Monitoring to Enable Simpler, Cheaper, Longer-Lived Surface Caps

    Energy Technology Data Exchange (ETDEWEB)

    Piet, Steven James; Breckenridge, Robert Paul; Burns, Douglas Edward

    2003-02-01

    Society has and will continue to generate hazardous wastes whose risks must be managed. For exceptionally toxic, long-lived, and feared waste, the solution is deep burial, e.g., deep geological disposal at Yucca Mtn. For some waste, recycle or destruction/treatment is possible. The alternative for other wastes is storage at or near the ground level (in someone’s back yard); most of these storage sites include a surface barrier (cap) to prevent downward water migration. Some of the hazards will persist indefinitely. As society and regulators have demanded additional proof that caps are robust against more threats and for longer time periods, the caps have become increasingly complex and expensive. As in other industries, increased complexity will eventually increase the difficulty in estimating performance, in monitoring system/component performance, and in repairing or upgrading barriers as risks are managed. An approach leading to simpler, less expensive, longer-lived, more manageable caps is needed. Our project, which started in April 2002, aims to catalyze a Barrier Improvement Cycle (iterative learning and application) and thus enable Remediation System Performance Management (doing the right maintenance neither too early nor too late). The knowledge gained and the capabilities built will help verify the adequacy of past remedial decisions, improve barrier management, and enable improved solutions for future decisions. We believe it will be possible to develop simpler, longer-lived, less expensive caps that are easier to monitor, manage, and repair. The project is planned to: a) improve the knowledge of degradation mechanisms in times shorter than service life; b) improve modeling of barrier degradation dynamics; c) develop sensor systems to identify early degradation; and d) provide a better basis for developing and testing of new barrier systems. This project combines selected exploratory studies (benchtop and field scale), coupled effects accelerated aging

  5. Testing, Modeling, and Monitoring to Enable Simpler, Cheaper, Longer-lived Surface Caps

    Energy Technology Data Exchange (ETDEWEB)

    Piet, S. J.; Breckenridge, R. P.; Burns, D. E.

    2003-02-25

    Society has and will continue to generate hazardous wastes whose risks must be managed. For exceptionally toxic, long-lived, and feared waste, the solution is deep burial, e.g., deep geological disposal at Yucca Mtn. For some waste, recycle or destruction/treatment is possible. The alternative for other wastes is storage at or near the ground level (in someone's back yard); most of these storage sites include a surface barrier (cap) to prevent downward water migration. Some of the hazards will persist indefinitely. As society and regulators have demanded additional proof that caps are robust against more threats and for longer time periods, the caps have become increasingly complex and expensive. As in other industries, increased complexity will eventually increase the difficulty in estimating performance, in monitoring system/component performance, and in repairing or upgrading barriers as risks are managed. An approach leading to simpler, less expensive, longer-lived, more manageable caps is needed. Our project, which started in April 2002, aims to catalyze a Barrier Improvement Cycle (iterative learning and application) and thus enable Remediation System Performance Management (doing the right maintenance neither too early nor too late). The knowledge gained and the capabilities built will help verify the adequacy of past remedial decisions, improve barrier management, and enable improved solutions for future decisions. We believe it will be possible to develop simpler, longer-lived, less expensive caps that are easier to monitor, manage, and repair. The project is planned to: (a) improve the knowledge of degradation mechanisms in times shorter than service life; (b) improve modeling of barrier degradation dynamics; (c) develop sensor systems to identify early degradation; and (d) provide a better basis for developing and testing of new barrier systems. This project combines selected exploratory studies (benchtop and field scale), coupled effects

  6. Testing and monitoring plan for the permanent isolation surface barrier prototype

    Energy Technology Data Exchange (ETDEWEB)

    Gee, G.W.; Cadwell, L.L.; Freeman, H.D.; Ligotke, M.W.; Link, S.O.; Romine, R.A.; Walters, W.H. Jr.

    1993-06-01

    This document is a testing and monitoring plan for a prototype barrier to be constructed at the Hanford Site in 1993. The prototype barrier is an aboveground structure engineered to demonstrate the basic features of an earthen cover system, designed to permanently isolate waste from the biosphere. These features include multiple layers of soil and rock materials and a low-permeability asphalt sublayer. The surface of the barrier consists of silt loam soil, vegetated with plants. The barrier sides are reinforced with rock or coarse earthen-fill to protect against wind and water erosion. The sublayers inhibit plant and animal intrusion and percolation of water. A series of tests will be conducted on the prototype over the next several years to evaluate barrier performance under extreme climatic conditions.

  7. Application of column tests and electrical resistivity methods for leachate transport monitoring

    Directory of Open Access Journals (Sweden)

    Wychowaniak Dorota

    2015-09-01

    Full Text Available Development of the human civilization leads to the pollution of environment. One of the contamination which are a real threat to soil and groundwater are leachates from landfills. In this paper the solute transport through soil was considered. For this purpose, the laboratory column tests of chlorides tracer and leachates transport on two soil samples have been carried out. Furthermore, the electrical resistivity method was applied as auxiliary tool to follow the movements of solute through the soil column what allowed to compare between the results obtained with column test method and electrical resistivity measurements. Breakthrough curves obtained by conductivity and resistivity methods represents similar trends which leads to the conclusion about the suitability of electrical resistivity methods for contamination transport monitoring in soil-water systems.

  8. Development And Testing Unmanned Aerial Systems To Study And Monitoring Volcanoes: INGV Experience Since 2004

    Science.gov (United States)

    Buongiorno, M. F.; Amici, S.; Doumaz, F.; Diaz, J. A.; Silvestri, M.; Musacchio, M.; Pieri, D. C.; Marotta, E.; Wright, K. C.; Sansivero, F.; Caliro, S.; Falcone, S.; Giulietti, F.

    2016-12-01

    Monitoring natural hazards such as active volcanoes requires specific instruments to measure many parameters (gas emissions, surface temperatures, surface deformation etc.) to determine the activity level of the volcano. Volcanoes in most cases present difficult and dangerous environment for scientists who need to take in situ measurements but also for manned aircrafts. Remote Sensing systems on board of satellite permit to measure a large number of parameters especially during the eruptive events but still show large limits to monitor volcanic precursors and phenomena at local scale (gas species emitted by fumarole or summit craters degassing plumes and surface thermal changes of few degrees). Since 2004 INGV started the analysis of unmanned Aerial Systems (UAV) to explore the operational aspects of UAV deployments. In 2006, INGV in partnership with department of Aerospace Division at University of Bologna, stared the development of a UAV system named RAVEN-INGV. The project was anticipated by a flight test on 2004. In the last years the large diffusion of smaller UAVS and drones opened new opportunities to perform the monitoring of volcanic areas. INGV teams developed strong collaboration with Jet Propulsion Laboratory (JPL) and University of Costa Rica (UCR) to cooperate in testing both UAV and miniaturized instruments to measures gas species and surface temperatures in volcanic environment. Between 2014 and 2015 specific campaigns has been performed in the active volcanoes in Italy (Campi Flegrei and Vulcano Island). The field and airborne acquisitions have also permitted the calibration and validation of Satellite data as ASTER and LANDSAT8 (in collaboration with USGS). We hope that the rapid increasing of technology developments will permit the use UAV systems to integrate geophysical measurements and contribute to the necessary calibration and validation of current and future satellite missions dedicated to the measurements of surface temperatures and gas

  9. Smart monitoring system based on adaptive current control for superconducting cable test

    Energy Technology Data Exchange (ETDEWEB)

    Arpaia, Pasquale [Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Napoli (Italy); Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Ballarino, Amalia; Montenero, Giuseppe [Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Daponte, Vincenzo [Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Department of Electronics, Information, and Bioengineering, Polytechnic of Milan, 20133 Milano (Italy); Svelto, Cesare [Department of Electronics, Information, and Bioengineering, Polytechnic of Milan, 20133 Milano (Italy)

    2014-12-15

    A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, “Performance improvement of a measurement station for superconducting cable test,” Rev. Sci. Instrum.83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

  10. Smart monitoring system based on adaptive current control for superconducting cable test.

    Science.gov (United States)

    Arpaia, Pasquale; Ballarino, Amalia; Daponte, Vincenzo; Montenero, Giuseppe; Svelto, Cesare

    2014-12-01

    A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, "Performance improvement of a measurement station for superconducting cable test," Rev. Sci. Instrum. 83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

  11. Design of a Loose Part Monitoring System Test-bed using CompactRIO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min-seok; Lee, Kwang-Dae; Lee, Eui-Jong [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    A loose part monitoring system (LPMS) is included in the NSSS integrity monitoring system (NIMS), which serves to detect loose parts in reactor coolant systems (RCS). LPMSs at Nuclear Power Plants (NPPs) in Korea follow the ASME OM standard and acquire data from 18 sensors simultaneously. Data acquisition requires a sampling rate of more than 50KHz along with a 12bit A/D converter. Existing LPMS equipment is composed of several different platforms, such as a digital signal processor (DSP), a field-programmable gate array (FPGA), a micro control unit (MCU), and electric circuit cards. These systems have vulnerabilities, such as discontinuance due to aging and incompatibility issues between different pieces of equipment. This paper suggests CompactRIO as a new platform. We devised a Test-bed using CompactRIO and demonstrate that the proposed method meets the criteria required by the standard. The LPMS provides an alert when an impact event occurs and provides information with which to analyze the location, energy, and mass of the loose parts. LPMSs in NPPs in Korea operate on a variety of platforms. Thus, these systems are vulnerable to discontinuances due to aging and incompatibilities arising from the use of different type of equipment. In order to solve these problems, this paper suggests CompactRIO as a new platform. It is a rugged, reconfigurable, high-performance industrial embedded system. The results of performance tests meet the criteria set by the current standard.

  12. A Low Cost System for Testing and Monitoring the Performance of Photovoltaic Module

    Directory of Open Access Journals (Sweden)

    POPESCU, V.

    2013-11-01

    Full Text Available The purpose of this paper is to develop a low cost system for testing and monitoring the performance of PV modules in outdoor conditions. In order to do this, we improved and adapted another measuring system. This system was developed by us and enables us to ensure the performance of the PV module through testing and monitoring, as well as saving collected data to a database. This database can be accessed through a graphical interface on a laptop connected to the system using serial interface. The error sources of this system are reduced to minimum because of human operators interfering with the system only through the graphical user interface. The Two Diode Model with series and parallel resistances was used to estimate the parameters of the electrical equivalent circuit for the PV module. This model will be simulated in CASPOC 2009. The performances of PV module were obtained in outdoor conditions and were saved to the database. They will be compared with the performances obtained through simulation, to prove the efficiency of the model.

  13. Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams

    Science.gov (United States)

    Solevi, Paola; Muñoz, Enrique; Solaz, Carles; Trovato, Marco; Dendooven, Peter; Gillam, John E.; Lacasta, Carlos; Oliver, Josep F.; Rafecas, Magdalena; Torres-Espallardo, Irene; Llosá, Gabriela

    2016-07-01

    In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector concepts proposed, Compton cameras are employed to detect prompt gammas and represent a valid candidate for real-time range verification. We present the first on-beam test of MACACO, a Compton telescope (multi-layer Compton camera) based on lanthanum bromide crystals and silicon photo-multipliers. The Compton telescope was first characterized through measurements and Monte Carlo simulations. The detector linearity was measured employing 22Na and Am-Be sources, obtaining about 10% deviation from linearity at 3.44 MeV. A spectral image reconstruction algorithm was tested on synthetic data. Point-like sources emitting gamma rays with energy between 2 and 7 MeV were reconstructed with 3-5 mm resolution. The two-layer Compton telescope was employed to measure radiation emitted from a beam of 150 MeV protons impinging on a cylindrical PMMA target. Bragg-peak shifts were achieved via adjustment of the PMMA target location and the resulting measurements used during image reconstruction. Reconstructed Bragg peak profiles proved sufficient to observe peak-location differences within 10 mm demonstrating the potential of the MACACO Compton Telescope as a monitoring device for ion-beam therapy.

  14. A new improved multicopter chassis structure tested on slope stability monitoring

    Science.gov (United States)

    Rossi, Guglielmo; Tanteri, Luca; Salvatici, Teresa; Scaduto, Gabriele; Tacconi Stefanelli, Carlo; Casagli, Nicola; Moretti, Sandro

    2017-04-01

    The multicopter has an increasing role in remote sensing and aerial photography. The piloting ease and the mechanical simplicity are the main reasons for drone diffusion as a hobby and for professional use. Usually multicopters have a "spider" structure with a central body and many radial arms that support the propulsion device. To improve the structure of the existing multicopter, the Department of Earth Sciences of Florence (DST) has developed and patented a new type of chassis structure that allows us to overcome some critical issues for scientific and heavy payload or long flight applications. The drone has an innovative perimetric chassis that fully supports flight dynamics. The new structure allows us to obtain high flight performance combined with low vibration transmission to the carried instruments. The new patented structure is implemented in two new prototypes of high performance drones completely developed by the Department of Earth Sciences of Florence: Saturn 2 and Saturn mini X-21. Saturn 2 is a high performance multi-role drone capable of carrying up to 14 kg of scientific instruments. Saturn Mini X-21 is a high performance drone, entirely 3D printed and specialized for digital and 3D rapid mapping. The Saturn mini X-21 was especially developed to obtain for the first time, by a drone, a 3D high resolution digital model for slope monitoring purposes of the Stromboli Sciara del Fuoco, a large inaccessible area that presents harsh flight conditions such as high persistent wind, rotors, volcanic ash and saltiness. The Saturn drones are mainly developed and tested, all around software and hardware, on slope stability monitoring. Four test cases are proposed, which were performed during the development and testing phase: a large area 3D survey (Scillato - Sicily), a harsh condition 3D survey (Stromboli -Sicily), a multitemporal 3D survey (Ricasoli - Tuscany) and the testing phase of measurement performed by onboard radar equipment.

  15. An ecosystem report on the Panama Canal: Monitoring the status of the forest communities and the watershed

    Science.gov (United States)

    Ibanez, R.; Condit, R.; Angehr, G.; Aguilar, S.; Garcia, T.; Martinez, R.; Sanjur, A.; Stallard, R.; Wright, S.J.; Rand, A.S.; Heckadon, S.

    2002-01-01

    In 1996, the Smithsonian Tropical Research Institute and the Republic of Panama's Environmental Authority, with support from the United States Agency for International Development, undertook a comprehensive program to monitor the ecosystem of the Panama Canal watershed. The goals were to establish baseline indicators for the integrity of forest communities and rivers. Based on satellite image classification and ground surveys, the 2790 km2 watershed had 1570 km2 of forest in 1997, 1080 km2 of which was in national parks and nature monuments. Most of the 490 km2 of forest not currently in protected areas lies along the west bank of the Canal, and its management status after the year 2000 turnover of the Canal from the U.S. to Panama remains uncertain. In forest plots designed to monitor forest diversity and change, a total of 963 woody plant species were identified and mapped. We estimate there are a total of 850-1000 woody species in forests of the Canal corridor. Forests of the wetter upper reaches of the watershed are distinct in species composition from the Canal corridor, and have considerably higher diversity and many unknown species. These remote areas are extensively forested, poorly explored, and harbor an estimated 1400-2200 woody species. Vertebrate monitoring programs were also initiated, focusing on species threatened by hunting and forest fragmentation. Large mammals are heavily hunted in most forests of Canal corridor, and there was clear evidence that mammal density is greatly reduced in hunted areas and that this affects seed predation and dispersal. The human population of the watershed was 113 000 in 1990, and grew by nearly 4% per year from 1980 to 1990. Much of this growth was in a small region of the watershed on the outskirts of Panama City, but even rural areas, including villages near and within national parks, grew by 2% per year. There is no sewage treatment in the watershed, and many towns have no trash collection, thus streams near large

  16. 对我国环境监测管理制度的思考%Status of Environmental Monitoring Management System in China

    Institute of Scientific and Technical Information of China (English)

    林建清; 洪华生

    2000-01-01

    分析了我国环境监测管理制度的现状及存在的问题,提出了改革和完善我国环境监测管理制度的思路。%This paper discusses the status of the environmental monitoring management system in China,analyses its difficulties ,and proposes some thoughts on reforming and improving the system.

  17. Test report on the machine-mounted continuous respirable dust monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kissell, F.N.; Thimons, E.D. [Pittsburgh Research Laboratory, Pittsburgh, PA (USA). National Institute for Occupational Safety and Health

    2001-07-01

    The machine-mounted continuous respirable dust monitor (MMCRDM) is a fixed-location area sampling device developed for possible use at the working face of an underground coal mine. This device, based on proprietary technology known as the tapered element oscillating microbalance, has evolved over the past eight years through a cooperative effort of the former Bureau of Mines, MSHA, and the Rupprecht & Patashnick Company in Albany, NY. The capability to measure respirable coal mine dust levels on a continuous basis, rather than depending solely on periodic samples obtained from the traditional coal mine dust samplers, has been a goal in the mining industry for nearly two decades. Recently, an extensive series of laboratory and underground tests was conducted by NIOSH with the cooperation of MSHA and coal operators to test the performance of the MMCRDM. In preliminary laboratory testing, the MMCRDM seemed to work well. However, in every underground test, when compared to reference samplers placed close to the inlet, the MMCRDM failed to meet the 25% accuracy criterion specified in the contract under which it was developed. Two reasons explain this failure: first, in most tests the bias (the relative discrepancy between the average MMCRDM concentration and the average reference sampler concentration) was too great. Second, the variability of the samplers used for reference comparison was too large. Finally, the underground testing of the MMCRDMs showed that they are quite unreliable at this stage of development. In the majority of mine tests, no more than 10 shifts of data were taken before the MMCRDM failed to function properly. Major breakdowns, requiring the return of the MMCRDM to the factory for repairs, occurred on average every 28 days. To be considered mine-worthy, MMCRDM reliability must be substantially improved. 6 refs., 7 figs.

  18. How to Get the Biggest Bang for Your Buck: Wildlife Monitoring on Shrublands of the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Derek Hall, Paul D. Greger

    2008-03-01

    The Nevada Test Site (NTS) covers 1,375 square miles and extends over portions of both the Mojave and Great Basin Deserts. The resulting diverse and complex flora and fauna exhibit elements of both deserts. There are 20 vegetation associations, composed primarily of shrubs, nested within 10 vegetation alliances. Of the more than 1,200 invertebrates and 339 vertebrates found in these shrubland habitats, 267 are considered sensitive or protected/regulated by federal or state laws. Wildlife and wildlife habitat monitoring ensures NTS activities comply with all federal and state laws enacted for the protection of these valuable biological resources. This paper describes the monitoring approach used at this large site. Monitoring techniques include conducting preactivity surveys, repeated sampling of permanent plots, proactively monitoring sensitive species, and collaborating with other agencies and biologists. Ways to make monitoring more efficient and examples of successful monitoring and collaborations are discussed.

  19. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    Science.gov (United States)

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  20. Polymorphic ventricular tachycardia due to variant angina diagnosed on Holter monitoring and confirmed with cold pressor test.

    Science.gov (United States)

    Öztürk, Semi; Aktemur, Tuğba; Kalyoncuoğlu, Muhsin; Durmuş, Gündüz; Can, Mehmet

    2017-04-01

    A 52-year-old man complaining of persistent recurring chest pain at night underwent coronary angiogram at another institution. Normal coronaries were observed and he was discharged with muscle spasmolytic prescription. Since symptoms had continued, 24-hour Holter monitoring was ordered at our facility and results revealed huge ST elevation and polymorphic ventricular tachycardia. Cold pressor test performed in catheterization laboratory also resulted in ventricular tachycardia. Nifedipine was prescribed and follow-up Holter monitoring revealed no further vasospastic episodes. Utility of 24-hour Holter rhythm monitoring and cold pressor test in patients with recurrent chest pain at night is demonstrated in this report.

  1. Oscillatory hydraulic testing as a strategy for NAPL source zone monitoring: Laboratory experiments

    Science.gov (United States)

    Zhou, YaoQuan; Cardiff, Michael

    2017-05-01

    Non-aqueous phase liquids (NAPLs) have a complex mode of transport in heterogeneous aquifers, which can result in pools and lenses of NAPLs (the ;source zone;) that are difficult to detect and can cause long-term contamination via slow dissolution into groundwater (the ;dissolved plume;). Characterizing the extent and evolution of NAPL contamination within the source zone is a useful strategy for designing and adapting appropriate remedial actions at many contaminated sites. As a NAPL flows into a given aquifer volume, the effective hydraulic conductivity (K) and specific storage (Ss) of the volume changes associated with the viscosity and compressibility of the impinging fluid, meaning that NAPL movement may be detectable with hydraulic testing. Recently, the use of oscillatory pumping tests - in which sinusoidal pumping variations are implemented and oscillatory pressure changes are detected at monitoring locations - has been suggested as a low-impact hydraulic testing strategy for characterizing aquifer properties (Cardiff et al., 2013; Zhou et al., 2016). Here, we investigate this strategy in an experimental laboratory sandbox where dyed vegetable oil is injected and allowed to migrate as a NAPL. Initial qualitative analyses demonstrate that measurable changes in pressure signal amplitude and phase provide clear evidence for NAPL plume emplacement and migration. Using the approach developed in Zhou et al. (2016), we then apply tomographic analyses to estimate the location of effective K changes (representing fluid changes) and their movement throughout time. This approach provides a method for monitoring ongoing NAPL movement without net extraction or injection of fluid, making it advantageous in field remediation applications.

  2. Acceptance testing of the Lasentec focused beam reflectance measurement (FBRM) monitor for slurry transfer applications at Hanford and Oak Ridge

    Science.gov (United States)

    Daymo, Eric A.; Hylton, Tom D.; May, Thomas H.

    1999-01-01

    The Lasentec M600F FBRM particle size and population monitor (Lasentec, Redmond, WA) was selected for deployment on radioactive slurry transfer systems at Oak Ridge National Laboratory and Hanford after extensive testing with `physical simulants.' These tests indicated that the monitor is able to measure the change in particle size distribution of concentrated (up to 35 vol.%) slurries at flow rates greater than 2 m/sec. As well, the monitor provided relatively stable mean particle size values when air bubbles were introduced to the slurry pipe test loop and when the color of the slurry was altered. Slurry samples taken during each test were analyzed with a laboratory particle size monitor. For kaolin slurry samples (length-cubed weighted mean of around 55 micrometers ), the Lasentec M600F FBRM in-line monitor measured length-cubed weighted mean particle sizes within 25% of those measured by a laboratory Lasentec M500LF monitor. This difference is thought primarily to be the result of sample handling issues. Regardless, this accuracy is acceptable for radioactive slurry transfer applications. Once deployed, the in-line Lasentec monitor is expected to yield significant cost savings at Hanford and Oak Ridge through the possible reduction in risk of pipeline blockage. In addition, fewer samples of radioactive slurries will need to be measured in the laboratory, further reducing costs and increasing safety.

  3. An Evaluation of North Korea’s Nuclear Test by Belbasi Nuclear Tests Monitoring Center-KOERI

    Science.gov (United States)

    Necmioglu, O.; Meral Ozel, N.; Semin, K.

    2009-12-01

    Bogazici University and Kandilli Observatory and Earthquake Research Institute (KOERI) is acting as the Turkish National Data Center (NDC) and responsible for the operation of the International Monitoring System (IMS) Primary Seismic Station (PS-43) under Belbasi Nuclear Tests Monitoring Center for the verification of compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) since February 2000. The NDC is responsible for operating two arrays which are part of the IMS, as well as for transmitting data from these stations to the International Data Centre (IDC) in Vienna. The Belbasi array was established in 1951, as a four-element (Benioff 1051) seismic array as part of the United States Atomic Energy Detection System (USAEDS). Turkish General Staff (TGS) and U.S. Air Force Technical Application Center (AFTAC) under the Defense and Economic Cooperation Agreement (DECA) jointly operated this short period array. The station was upgraded and several seismometers were added to array during 1951 and 1994 and the station code was changed from BSRS (Belbasi Seismic Research Station) to BRTR-PS43 later on. PS-43 is composed of two sub-arrays (Ankara and Keskin): the medium-period array with a ~40 km radius located in Ankara and the short-period array with a ~3 km radius located in Keskin. Each array has a broadband element located at the middle of the circular geometry. Short period instruments are installed at depth 30 meters from the surface while medium and broadband instruments are installed at depth 60 meters from surface. On 25 May 2009, The Democratic People’s Republic of Korea (DPRK) claimed that it had conducted a nuclear test. Corresponding seismic event was recorded by IMS and IDC released first automatic estimation of time (00:54:43 GMT), location (41.2896°N and 129.0480°E) and the magnitude (4.52 mb) of the event in less than two hours time (USGS: 00:54:43 GMT; 41.306°N, 129.029°E; 4.7 mb) During our preliminary analysis of the 25th May 2009 DPRK

  4. Monitoring Training Progress During Exercise Training in Cancer Survivors : A Submaximal Exercise Test as an Alternative for a Maximal Exercise Test?

    NARCIS (Netherlands)

    May, Anne M.; van Weert, Ellen; Korstjens, Irene; Hoekstra-Weebers, Josette E.; van der Schans, Cees P.; Zonderland, Maria L.; Mesters, Ilse; van den Borne, Bart; Ros, Wynand J.

    May AM, van Weert E, Korstjens 1, Hoekstra-Weebers JE, van der Schans CP, Zonderland ML, Mesters 1, van den Borne B, Ros WJ. Monitoring training progress during exercise training in cancer survivors: a submaximal exercise test as an alternative for a maximal exercise test? Arch Phys Med Rehabil

  5. In situ observations from STEREO/PLASTIC: a test for L5 space weather monitors

    Directory of Open Access Journals (Sweden)

    K. D. C. Simunac

    2009-10-01

    Full Text Available Stream interaction regions (SIRs that corotate with the Sun (corotating interaction regions, or CIRs are known to cause recurrent geomagnetic storms. The Earth's L5 Lagrange point, separated from the Earth by 60 degrees in heliographic longitude, is a logical location for a solar wind monitor – nearly all SIRs/CIRs will be observed at L5 several days prior to their arrival at Earth. Because the Sun's heliographic equator is tilted about 7 degrees with respect to the ecliptic plane, the separation in heliographic latitude between L5 and Earth can be more than 5 degrees. In July 2008, during the period of minimal solar activity at the end of solar cycle 23, the two STEREO observatories were separated by about 60 degrees in longitude and more than 4 degrees in heliographic latitude. This time period affords a timely test for the practical application of a solar wind monitor at L5. We compare in situ observations from PLASTIC/AHEAD and PLASTIC/BEHIND, and report on how well the BEHIND data can be used as a forecasting tool for in situ conditions at the AHEAD spacecraft with the assumptions of ideal corotation and minimal source evolution. Preliminary results show the bulk proton parameters (density and bulk speed are not in quantitative agreement from one observatory to the next, but the qualitative profiles are similar.

  6. 10 CFR 830 Major Modification Determination for the Advanced Test Reactor Remote Monitoring and Management Capability

    Energy Technology Data Exchange (ETDEWEB)

    Bohachek, Randolph Charles [Idaho National Laboratory (INL), Idaho Falls, ID (United States)

    2015-09-01

    The Advanced Test Reactor (ATR; TRA-670), which is located in the ATR Complex at Idaho National Laboratory, was constructed in the 1960s for the purpose of irradiating reactor fuels and materials. Other irradiation services, such as radioisotope production, are also performed at ATR. While ATR is safely fulfilling current mission requirements, assessments are continuing. These assessments intend to identify areas to provide defense–in-depth and improve safety for ATR. One of the assessments performed by an independent group of nuclear industry experts recommended that a remote accident management capability be provided. The report stated that: “contemporary practice in commercial power reactors is to provide a remote shutdown station or stations to allow shutdown of the reactor and management of long-term cooling of the reactor (i.e., management of reactivity, inventory, and cooling) should the main control room be disabled (e.g., due to a fire in the control room or affecting the control room).” This project will install remote reactor monitoring and management capabilities for ATR. Remote capabilities will allow for post scram reactor management and monitoring in the event the main Reactor Control Room (RCR) must be evacuated.

  7. Testing ZigBee Motes for Monitoring Refrigerated Vegetable Transportation under Real Conditions

    Directory of Open Access Journals (Sweden)

    Luis Ruiz-Garcia

    2010-05-01

    Full Text Available Quality control and monitoring of perishable goods during transportation and delivery services is an increasing concern for producers, suppliers, transport decision makers and consumers. The major challenge is to ensure a continuous ‘cold chain’ from producer to consumer in order to guaranty prime condition of goods. In this framework, the suitability of ZigBee protocol for monitoring refrigerated transportation has been proposed by several authors. However, up to date there was not any experimental work performed under real conditions. Thus, the main objective of our experiment was to test wireless sensor motes based in the ZigBee/IEEE 802.15.4 protocol during a real shipment. The experiment was conducted in a refrigerated truck traveling through two countries (Spain and France which means a journey of 1,051 kilometers. The paper illustrates the great potential of this type of motes, providing information about several parameters such as temperature, relative humidity, door openings and truck stops. Psychrometric charts have also been developed for improving the knowledge about water loss and condensation on the product during shipments.

  8. Can Commercial Digital Cameras Be Used as Multispectral Sensors? A Crop Monitoring Test

    Directory of Open Access Journals (Sweden)

    Bruno Roux

    2008-11-01

    Full Text Available The use of consumer digital cameras or webcams to characterize and monitor different features has become prevalent in various domains, especially in environmental applications. Despite some promising results, such digital camera systems generally suffer from signal aberrations due to the on-board image processing systems and thus offer limited quantitative data acquisition capability. The objective of this study was to test a series of radiometric corrections having the potential to reduce radiometric distortions linked to camera optics and environmental conditions, and to quantify the effects of these corrections on our ability to monitor crop variables. In 2007, we conducted a five-month experiment on sugarcane trial plots using original RGB and modified RGB (Red-Edge and NIR cameras fitted onto a light aircraft. The camera settings were kept unchanged throughout the acquisition period and the images were recorded in JPEG and RAW formats. These images were corrected to eliminate the vignetting effect, and normalized between acquisition dates. Our results suggest that 1 the use of unprocessed image data did not improve the results of image analyses; 2 vignetting had a significant effect, especially for the modified camera, and 3 normalized vegetation indices calculated with vignetting-corrected images were sufficient to correct for scene illumination conditions. These results are discussed in the light of the experimental protocol and recommendations are made for the use of these versatile systems for quantitative remote sensing of terrestrial surfaces.

  9. Testing ZigBee motes for monitoring refrigerated vegetable transportation under real conditions.

    Science.gov (United States)

    Ruiz-Garcia, Luis; Barreiro, Pilar; Robla, Jose Ignacio; Lunadei, Loredana

    2010-01-01

    Quality control and monitoring of perishable goods during transportation and delivery services is an increasing concern for producers, suppliers, transport decision makers and consumers. The major challenge is to ensure a continuous 'cold chain' from producer to consumer in order to guaranty prime condition of goods. In this framework, the suitability of ZigBee protocol for monitoring refrigerated transportation has been proposed by several authors. However, up to date there was not any experimental work performed under real conditions. Thus, the main objective of our experiment was to test wireless sensor motes based in the ZigBee/IEEE 802.15.4 protocol during a real shipment. The experiment was conducted in a refrigerated truck traveling through two countries (Spain and France) which means a journey of 1,051 kilometers. The paper illustrates the great potential of this type of motes, providing information about several parameters such as temperature, relative humidity, door openings and truck stops. Psychrometric charts have also been developed for improving the knowledge about water loss and condensation on the product during shipments.

  10. Monitoring accelerated carbonation on standard Portland cement mortar by nonlinear resonance acoustic test

    Science.gov (United States)

    Eiras, J. N.; Kundu, T.; Popovics, J. S.; Monzó, J.; Borrachero, M. V.; Payá, J.

    2015-03-01

    Carbonation is an important deleterious process for concrete structures. Carbonation begins when carbon dioxide (CO2) present in the atmosphere reacts with portlandite producing calcium carbonate (CaCO3). In severe carbonation conditions, C-S-H gel is decomposed into silica gel (SiO2.nH2O) and CaCO3. As a result, concrete pore water pH decreases (usually below 10) and eventually steel reinforcing bars become unprotected from corrosion agents. Usually, the carbonation of the cementing matrix reduces the porosity, because CaCO3 crystals (calcite and vaterite) occupy more volume than portlandite. In this study, an accelerated carbonation-ageing process is conducted on Portland cement mortar samples with water to cement ratio of 0.5. The evolution of the carbonation process on mortar is monitored at different levels of ageing until the mortar is almost fully carbonated. A nondestructive technique based on nonlinear acoustic resonance is used to monitor the variation of the constitutive properties upon carbonation. At selected levels of ageing, the compressive strength is obtained. From fractured surfaces the depth of carbonation is determined with phenolphthalein solution. An image analysis of the fractured surfaces is used to quantify the depth of carbonation. The results from resonant acoustic tests revealed a progressive increase of stiffness and a decrease of material nonlinearity.

  11. Validation of heart rate derived from a physiological status monitor-embedded compression shirt against criterion ECG.

    Science.gov (United States)

    Dolezal, B A; Boland, D M; Carney, J; Abrazado, M; Smith, D L; Cooper, C B

    2014-01-01

    Firefighters are subject to extreme environments and high physical demands when performing duty-related tasks. Recently, physiological status monitors (PSM) have been embedded into a compression shirt to enable firefighters to measure, visualize, log, and transmit vital metrics such as heart rate (HR) to aid in cardiovascular risk identification and mitigation, thereby attempting to improve the health, fitness, and safety of this population. The purpose of this study was to validate HR recorded by the PSM-embedded compression shirt against a criterion standard laboratory ECG-derived HR when worn concurrently with structural firefighting personal protective equipment (PPE) during four simulated firefighting activities. Ten healthy, college-age men (mean ± SD: age: 21 ± 1 yr; body mass: 91 ± 10 kg; body mass index: 26.9 ± 3.1 kg/m(2)) completed four tasks that are routinely performed during firefighting operations: outdoor fast-paced walking (FW), treadmill walking (TW), searching/crawling (SC), and ascending/descending stairs (AD). They wore the PSM-embedded compression shirt under structural firefighting PPE. HR was recorded concurrently by the PSM-embedded compression shirt and a portable metabolic measurement system accompanied with a standard 12-lead electrocardiograph that was used to provide criterion measures of HR. For all four tasks combined there was very high correlation of PSM and ECG HR (r > 0.99; SEE 0.84 /min) with a mean difference (bias) of -0.02 /min and limits of agreement of -0.07 to 0.02 /min. For individual tasks, the correlations were also high (r-values = 0.99; SEE 0.81-0.89). The mean bias (limits of agreement) was: FW 0.03 (-0.09 to 0.14); TW 0.04 (-0.05 to 0.12); SC -0.01 (-0.12 to 0.10); AD -0.13 (-0.21 to -0.04) /min. These findings demonstrate that the PSM-embedded compression shirt provides a valid measure of HR during simulated firefighting activities when compared with a standard 12-lead ECG.

  12. An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

    Science.gov (United States)

    Rinehart, Aidan W.; Simon, Donald L.

    2015-01-01

    This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

  13. Cavity beam position monitor system for the Accelerator Test Facility 2

    Directory of Open Access Journals (Sweden)

    Y. I. Kim

    2012-04-01

    Full Text Available The Accelerator Test Facility 2 (ATF2 is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1  μm for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.

  14. Monitoring and Ana