WorldWideScience

Sample records for monitor pump performance

  1. Monitoring the performance of Aux. Feedwater Pump using Smart Sensing Model

    Energy Technology Data Exchange (ETDEWEB)

    No, Young Gyu; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2015-10-15

    Many artificial intelligence (AI) techniques equipped with learning systems have recently been proposed to monitor sensors and components in NPPs. Therefore, the objective of this study is the development of an integrity evaluation method for safety critical components such as Aux. feedwater pump, high pressure safety injection (HPSI) pump, etc. using smart sensing models based on AI techniques. In this work, the smart sensing model is developed at first to predict the performance of Aux. feedwater pump by estimating flowrate using group method of data handing (GMDH) method. If the performance prediction is achieved by this feasibility study, the smart sensing model will be applied to development of the integrity evaluation method for safety critical components. Also, the proposed algorithm for the performance prediction is verified by comparison with the simulation data of the MARS code for station blackout (SBO) events. In this study, the smart sensing model for the prediction performance of Aux. feedwater pump has been developed. In order to develop the smart sensing model, the GMDH algorithm is employed. The GMDH algorithm is the way to find a function that can well express a dependent variable from independent variables. This method uses a data structure similar to that of multiple regression models. The proposed GMDH model can accurately predict the performance of Aux.

  2. Performance monitoring of a bubble pumped solar domestic hot water system - final report

    Energy Technology Data Exchange (ETDEWEB)

    Makuch, P.D.; Harrison, S.J. [Queen`s Univ., Kingston, ON (Canada). Solar Calorimetry Lab.

    1995-12-01

    A new type of solar domestic hot water (SDHW) system for cold climates was described. The bubble pump system is self pumping and self regulating (it circulates anti-freeze). The system transports heat from roof mounted solar collectors to a thermal storage located at a lower level when there is available solar radiation. The design is unique in that it has no moving parts and requires no external electrical or mechanical input to operate. A unit was installed on a row house in Kingston, Ontario, to evaluate its performance. The average daily solar fraction was 32.4 per cent, and the average system efficiency for the monitored period was 13.4 per cent. This was below expectations due to low hot water demand. Performance improved somewhat towards the end of the monitoring period due to increased demand for hot water, improvements to the system, and increased solar insulation. A more realistic annual performance was estimated at 19 per cent for system efficiency and 41 per cent for solar fraction. Further improvements could be expected, especially in mid-winter performance, if the solar collector slope could be increased to a value of 45 to 60 degrees to the horizontal. 8 refs., 14 tabs., 9 figs.

  3. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  4. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  5. Monitored performance of residential geothermal heat pumps in central Texas and Southern Michigan

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, W.N.

    1997-11-01

    This report summarizes measured performance of residential geothermal heat pumps (GHP`s) that were installed in family housing units at Ft. Hood, Texas and at Selfridge Air National Guard base in Michigan. These units were built as part of a joint Department of Defense/Department of Energy program to evaluate the energy savings potential of GHP`s installed at military facilities. At the Ft. Hood site, the GHP performance was compared to conventional forced air electric air conditioning and natural gas heating. At Selfridge, the homes under test were originally equipped with electric baseboard heat and no air conditioning. Installation of the GHP systems at both sites was straightforward but more problems and costs were incurred at Selfridge because of the need to install ductwork in the homes. The GHP`s at both sites produced impressive energy savings. These savings approached 40% for most of the homes tested. The low cost of energy on these bases relative to the incremental cost of the GHP conversions precludes rapid payback of the GHP`s from energy savings alone. Estimates based on simple payback (no inflation and no interest on capital) indicated payback times from 15 to 20 years at both sites. These payback times may be reduced by considering the additional savings possible due to reduced maintenance costs. Results are summarized in terms of 15 minute, hourly, monthly, and annual performance parameters. The results indicate that all the systems were working properly but several design shortcomings were identified. Recommendations are made for improvements in future installations at both sites.

  6. Field Monitoring Protocol: Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  7. Field Monitoring Protocol. Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maguire, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  8. Field Monitoring Protocol. Mini-Split Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tomerlin, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, E. [Mountain Energy Partnership, Longmont, CO (United States)

    2011-03-01

    This Building America program report provides a detailed method for accurately measuring and monitoring performance of a residential mini-split heat pump, which will be used in high-performance retrofit applications.

  9. High Performance Space Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — PDT is proposing a High Performance Space Pump based upon an innovative design using several technologies. The design will use a two-stage impeller, high temperature...

  10. Condition monitoring of rotary blood pumps.

    Science.gov (United States)

    Jammu, V B; Malanoski, S; Walter, T; Smith, W

    1997-01-01

    Long-term, trouble-free operation of ventricular assist devices (VADs) is critical to the patient. A catastrophic failure of the VAD could cost the patient's life, thus defeating the purpose of the device. The targeted 90% 5 year reliability also implies that the average device life would exceed the 5 year limit. Time based explantation of the device after the fifth year will replace many devices with significant additional life, subject the patient to unnecessary surgical risk, and increase costs. To preclude the need for time based replacements and prevent catastrophic failures, a condition monitor is proposed in this article for early detection of faults in VADs. To develop this monitor, the effectiveness of various sensing and monitoring methods for determining the VAD condition is investigated. A Hemadyne pump was instrumented with a set of eight sensors, and a series of experiments were performed to record and analyze signals from the normal and abnormal pumps with five different faults. Statistical, spectral, envelope, and ensemble averaging analyses were performed to characterize changes in sensor signals due to faults. Experimental results indicate that statistical and frequency information from the acceleration and dynamic pressure signals can clearly detect and identify various VAD faults.

  11. Monitoring actual performance of ground source heat pump system using GPRS-based data transmission:A case analysis in Tangshan

    Institute of Scientific and Technical Information of China (English)

    杜红普; 孔祥飞; 李敏; 齐承英

    2015-01-01

    The energy efficiency monitoring is an essential precondition for ground source heat pump system’s controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs (coefficient of performance) are 2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.

  12. Monitoring DNAPL pumping using integrated geophysical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Newmark, R.L.

    1997-01-01

    The removal of DNAPL during pumping was monitored. At Hill AFB in Utah, a free-product DNAPL plume (predominantly TCE, with some TCA, PCE, methylene chloride) is pooled in water-wet soil on a thick clay aquitard. Groundwater pumping at Operable Unit 2 began in 1994; to date, nearly 30,000 gal DNAPL have been recovered. From Sept. 1994 through Sept. 1995, changes in the basin during DNAPL pumping were monitored using fiber optic chemical sensors, neutron logs, and electrical resistance tomography (ERT). The first two sensor types verify the presence of DNAPL in vicinity of 3 boreholes which form a cross section from the perimeter of the basin to its center. Cross borehole ERT images the changes in formation electrical properties due to removal of DNAPL, extending the understanding of DNAPL removal between the boreholes. During pumping, electrical resistivities decreased; we suggest these decreases are directly caused by the reduction in DNAPL. During ground water pumping, water with relatively low resistivity replaces some of the DNAPL pockets as the highly insulating DNAPL is removed. Results suggest that, as DNAPL is pumped from a nearby well, product slowly drains along the top of an aquitard and into the pump well, where it collects.

  13. Field Monitoring Protocol: Mini-Split Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, D.; Fang, X.; Tomerlin, J.; Winkler, J.; Hancock, E.

    2011-03-01

    The report provides a detailed method for accurately measuring and monitoring performance of a residential Mini-Split Heat Pump. It will be used in high-performance retrofit applications, and as part of DOE's Building America residential research program.

  14. Monitoring the thermal performance of a heat pump with borehole heat exchangers in Lugano (TI); Projet: mesure des performances thermiques d'une PAC sur sondes geothermiques a Lugano (TI)

    Energy Technology Data Exchange (ETDEWEB)

    Pahud, D.; Lachal, B.

    2001-07-01

    This report presents a heat pump system installed in a single-family house in Lugano, Switzerland, and the results of its monitoring for nine months. The 14 kW heat pump is meant exclusively for space heating while the domestic hot water is provided by a solar water heater with 7.8 m{sup 2} collector area. The cold source of the heat pump is formed by three 80 m deep underground wells from which the geothermal energy is extracted by water circulation. The installation allows to transfer excess heat from the solar collector to the underground wells. The whole system is equipped with a couple of flow meters, temperature sensors and electric counters, in order to characterise its dynamic response and efficiency. Diagrams show monthly values of the thermal energy extracted from the wells, the energy re-injected to the wells, the energy delivered by the heat pump as well as its electrical energy consumption. The heat pump coefficient of performance, which is roughly 4, is discussed.

  15. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinsin, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance results from a test house equipped with a parallel solar augmented heat pump system with off-peak storage and a utility interconnection back-up, are presented. The collector array consisted of 12 air heating flat plates with a 9 l/sec flow. Thermal storage was consigned to a 260 cu ft crushed limestone pebble bed, with an 8.8 kW heat pump used to draw heat from storage during off-peak hours and a 15 kW electrical resistance heater used to charge the pebble bed. Monitoring and data recording were carried out on all energy inputs and outputs of the systems, and a modified TRNSYS program was employed to model the system performance. The data indicate that although the system offered the possibility of reducing the utility capacity, the addition of the solar system did not significantly augment the performance of the heat-pump system, at least in terms of the cost of supplementary electricity.

  16. Performance of the continuous glucose monitoring system (CGMS) during development of ketosis in patients on insulin pump therapy

    NARCIS (Netherlands)

    Pfuetzner, J.; Forst, T.; Butzer, R.; Forst, S.; Weber, M. M.; Pfuetzner, A. H.; Pfuetzner, A.

    2006-01-01

    Aims Ketoacidosis is one of the most severe complications of Type 1 diabetes. Development of ketosis leads to substantial shifts in electrolyte and ion concentrations in the different fluid compartments of the body. This study was performed to investigate the performance of the continuous glucose mo

  17. Using the motor to monitor pump conditions

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1996-12-01

    When the load of a mechanical device being driven by a motor changes, whether in response to changes in the overall process or changes in the performance of the driven device, the motor inherently responds. For induction motors, the current amplitude and phase angle change as the shaft load changes. By examining the details of these changes in amplitude and phase, load fluctuations of the driven device can be observed. The usefulness of the motor as a transducer to improve the understanding of devices with high torque fluctuations, such as positive displacement compressors and motor-operated valves, has been recognized and demonstrated for a number of years. On such devices as these, the spectrum of the motor current amplitude, phase, or power normally has certain characteristic peaks associated with various load components, such as the piston stroke or gear tooth meshing frequencies. Comparison and trending of the amplitudes of these peaks has been shown to provide some indication of their mechanical condition. For most centrifugal pumps, the load fluctuations are normally low in torque amplitude, and as a result, the motor experiences a correspondingly lower level of load fluctuation. However, both laboratory and field test data have demonstrated that the motor does provide insight into some important pump performance conditions, such as hydraulic stability and pump-to-motor alignment. Comparisons of other dynamic signals, such as vibration and pressure pulsation, to motor data for centrifugal pumps are provided. The effects of inadequate suction head, misalignment, mechanical and hydraulic unbalance on these signals are presented.

  18. Performance of a Centrifugal Slurry Pump

    Directory of Open Access Journals (Sweden)

    Hawas Yahya Bajawi

    2014-02-01

    Full Text Available The aim of this study was to experimentally investigate the effect of speed, concentration and size of slurry on the performance of a centrifugal pump. For this purpose a facility was built where the performance of a centrifugal slurry pump was examined using aggregate slurry. Three sizes of slurry with three concentrations and at three impeller speeds were used for the performance investigations of a centrifugal slurry pump. As a reference performance the performance of centrifugal slurry pump was also tested with clean water. The performance of pump has been reported as variations of head, power and efficiency at various flow rates along with the system characteristics of the pump. The results reveal that the pump performance is grossly affected by the type of slurry, its concentration and size. Besides this the variation in speed also affects the performance as is observed in pumps with water. The maximum decrease in the head, with respect to clear water, at the operating point was found to be 47% for aggregate for size 20 mm, 15% concentration and 2600 rpm. The maximum decrement in efficiency at operating point for aggregate was found to be 47% for 4 mm size, 15% concentration and at 2200 rpm. The power increment requirement for aggregate was 9% for 4 mm size, 15% concentration and 2600 rpm.

  19. High performance heat pump absorption cycles

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.; Longo, G.; Rossetto, L.

    1988-10-01

    Absorption heat pumps can provide high performances when operating in suitable cycles with multiple effects. This report describes some multistage cycles and evaluates the coefficient of performance realistically obtainable both in winter and summer working conditions.

  20. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  1. Commercial absorption heat pumps (design, performance)

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. (Padua Univ. (Italy). Ist. di Fisica Tecnica)

    1986-04-01

    After a historical review of the development of absorption heat pumps, a critical analysis is presented of the design and operation of typical 25-40 kW, commercially available heat pumps. This engineering critique is followed by an analysis of the performance of 25 kW plant thoroughly tested to provide, by means of statistically significant data, a reliable assessment of the coefficient of performance and capacity in function of the cold source temperature for different return temperatures.

  2. Performance of a New Lightweight Reciprocating Pump

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, J C

    2005-06-09

    A new four-chamber piston pump design has been fabricated and tested. The small-scale propellant pump is intended to be powered by gas at elevated temperatures, e.g. in a gas-generator cycle rocket propulsion system. Two key features are combined for the first time: leak-tight liquid-cooled seals, and a high throughput per unit hardware mass. Measured performance curves quantify flows, pressures, leakage, volumetric efficiency, and tank pressure requirements. A pair of 300-gram pumps operating with significant margin could deliver fuel and oxidizer at 5 MPa to a compact lightweight 1000-N engine, while tank pressure remains at 0.35 MPa. Pump weight is well below one percent of thrust, as is typical for launch vehicle engines. Applications include small upper stages, aggressive maneuvers in space, and miniature launch vehicles for Mars ascent.

  3. INVESTIGATION OF PERFORMANCE CURVES OF THREE STAGE DEEP WELL PUMPS

    OpenAIRE

    Gölcü, Mustafa

    2002-01-01

    In literature, pumps which are known as vertical turbine pump (VTP) have been designed to work vertically. Today, they are known as deep well pumps. These pumps are especially used in narrow and very deep wells where the surface sources are insufficient. Therefore, it is necessary to select suitable stage number to benefit from deep well pumps efficiently. In this study, a new deep well pump has been designed and the performances of three stage deep well pumps have been investigated experimen...

  4. Overall control and monitoring systems for pumped storage plants

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, B.; Cvetko, H.

    1982-06-01

    The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.

  5. Theoretical Prediction of the Pumping Performance of Dry Pumps (Taking the Scroll Pump and the Screw Pump by Way of Example)

    Science.gov (United States)

    Sawada, Tadashi; Ohbayashi, Tetsuro

    Since almost all commercially provided dry pumps are of the positive displacement type, the leak flow through clearance between displacement chambers in the pump is a dominant factor which determines pumping performance. Prediction methods for the pumping performance of dry pumps are explained by comparing it to the scroll pump and the screw pump. The scroll pump has long clearances, but the screw pump has relatively short ones, and the volume of the chambers reduces from the inlet toward the outlet in the scroll pump, but that in the screw pump is kept constant throughout the pumping process. Such a structural difference produces a small difference in the way of treating leak flow. These two methods can be applied to the other dry pumps requiring only minor modification.

  6. Selection of Sampling Pumps Used for Groundwater Monitoring at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Schalla, Ronald; Webber, William D.; Smith, Ronald M.

    2001-11-05

    The variable frequency drive centrifugal submersible pump, Redi-Flo2a made by Grundfosa, was selected for universal application for Hanford Site groundwater monitoring. Specifications for the selected pump and five other pumps were evaluated against current and future Hanford groundwater monitoring performance requirements, and the Redi-Flo2 was selected as the most versatile and applicable for the range of monitoring conditions. The Redi-Flo2 pump distinguished itself from the other pumps considered because of its wide range in output flow rate and its comparatively moderate maintenance and low capital costs. The Redi-Flo2 pump is able to purge a well at a high flow rate and then supply water for sampling at a low flow rate. Groundwater sampling using a low-volume-purging technique (e.g., low flow, minimal purge, no purge, or micropurgea) is planned in the future, eliminating the need for the pump to supply a high-output flow rate. Under those conditions, the Well Wizard bladder pump, manufactured by QED Environmental Systems, Inc., may be the preferred pump because of the lower capital cost.

  7. Condition monitoring, diagnostic and controlling tool for boiler feed pump

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Sohail [Siemens AG, Muelheim (Germany). Energy Sector; Leithner, Reinhard; Kosyna, Guenter [TU Braunschweig (Germany)

    2010-07-01

    The boiler feed pump is an important component of a thermal power generation cycle and demands high safety and unquestionable availability for flexible power plant operation. In this research paper, the methodology of a general purpose condition monitoring, diagnostic and controlling tool is presented, which can address the challenges of operational safety and availability as well as optimal operation of a boiler feed pump. This tool not only effectively records the life time consumption of both casings and rotors and monitors the small gaps between casings and rotors but also suggests appropriate actions in order to ensure that the pump operates within the allowable design limits. (orig.)

  8. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.

  9. Transient two-phase performance of LOFT reactor coolant pumps

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.H.; Modro, S.M.

    1983-01-01

    Performance characteristics of Loss-of-Fluid Test (LOFT) reactor coolant pumps under transient two-phase flow conditions were obtained based on the analysis of two large and small break loss-of-coolant experiments conducted at the LOFT facility. Emphasis is placed on the evaluation of the transient two-phase flow effects on the LOFT reactor coolant pump performance during the first quadrant operation. The measured pump characteristics are presented as functions of pump void fraction which was determined based on the measured density. The calculated pump characteristics such as pump head, torque (or hydraulic torque), and efficiency are also determined as functions of pump void fractions. The importance of accurate modeling of the reactor coolant pump performance under two-phase conditions is addressed. The analytical pump model, currently used in most reactor analysis codes to predict transient two-phase pump behavior, is assessed.

  10. Dual-stroke heat pump field performance

    Science.gov (United States)

    Veyo, S. E.

    1984-11-01

    Two nearly identical proprototype systems, each employing a unique dual-stroke compressor, were built and tested. One was installed in an occupied residence in Jeannette, Pa. It has provided the heating and cooling required from that time to the present. The system has functioned without failure of any prototypical advanced components, although early field experience did suffer from deficiencies in the software for the breadboard micro processor control system. Analysis of field performance data indicates a heating performance factor (HSPF) of 8.13 Stu/Wa, and a cooling energy efficiency (SEER) of 8.35 Scu/Wh. Data indicate that the beat pump is oversized for the test house since the observed lower balance point is 3 F whereas 17 F La optimum. Oversizing coupled with the use of resistance heat ot maintain delivered air temperature warmer than 90 F results in the consumption of more resistance heat than expected, more unit cycling, and therefore lower than expected energy efficiency. Our analysis indicates that with optimal mixing the dual stroke heat pump will yield as HSFF 30% better than a single capacity heat pump representative of high efficiency units in the market place today for the observed weather profile.

  11. Monitoring the thermal performance of a heat pump coupled to geothermal probes at Lugano (Switzerland); Mesure des performances thermiques d'une pompe a chaleur couplee sur des sondes geothermiques a Lugano (TI)

    Energy Technology Data Exchange (ETDEWEB)

    Pahud, D. [Scuola Universitaria Professionale della Svizzera Italiana (SUPSI), Laboratorio Energia Ecologia ed Economia (LEEE), Dipartimento Ambiente, Costruzioni e Design DACD, Trevano-Canobbio (Switzerland); Lachal, B. [Universite de Geneve, Centre Universitaire d' Etude des Problemes de l' Energie (CUEPE), Geneve (Switzerland)

    2004-07-01

    A heat pump system was experimentally investigated in a measuring campaign over two years and in additional dynamic system simulations using a model based on TRNSYS. The water-water heat pump delivers 14 kW thermal power at 0 {sup o}C/35 {sup o}C and uses 3 borehole heat exchangers of 80 m length each. It heats a single-family house of about 250 m{sup 2} of heated floor area, built in the 80es, which is also equipped with 7.8 m{sup 2} of solar collectors for hot water preparation. After two years of measurements, the thermal performances of the system are still very high and no performance decrease has been detected. The heat pump reaches quite a high seasonal performance factor of 4.1 to 4.2. A linear dependence between the monthly performance factor and the mean temperature difference between the heat carrier fluids circulating in the condenser and the evaporator has been identified.

  12. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. K. [Johnson Research LLC, Pueblo West, CO (United States)

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system's Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.

  13. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  14. A Numerical Study on System Performance of Groundwater Heat Pumps

    Directory of Open Access Journals (Sweden)

    Jin Sang Kim

    2015-12-01

    Full Text Available Groundwater heat pumps have energy saving potential where the groundwater resources are sufficient. System Coefficients of Performance (COPs are measurements of performance of groundwater heat pump systems. In this study, the head and power of submersible pumps, heat pump units, piping, and heat exchangers are expressed as polynomial equations, and these equations are solved numerically to determine the system performance. Regression analysis is used to find the coefficients of the polynomial equations from a catalog of performance data. The cooling and heating capacities of water-to-water heat pumps are determined using Energy Plus. Results show that system performance drops as the water level drops, and the lowest flow rates generally achieve the highest system performance. The system COPs are used to compare the system performance of various system configurations. The groundwater pumping level and temperature provide the greatest effects on the system performance of groundwater heat pumps along with the submersible pumps and heat exchangers. The effects of groundwater pumping levels, groundwater temperatures, and the heat transfer coefficient in heat exchanger on the system performance are given and compared. This analysis needs to be included in the design process of groundwater heat pump systems, possibly with analysis tools that include a wide range of performance data.

  15. Performance enhancement of a pump impeller using optimal design method

    Science.gov (United States)

    Jeon, Seok-Yun; Kim, Chul-Kyu; Lee, Sang-Moon; Yoon, Joon-Yong; Jang, Choon-Man

    2017-04-01

    This paper presents the performance evaluation of a regenerative pump to increase its efficiency using optimal design method. Two design parameters which define the shape of the pump impeller, are introduced and analyzed. Pump performance is evaluated by numerical simulation and design of experiments(DOE). To analyze three-dimensional flow field in the pump, general analysis code, CFX, is used in the present work. Shear stress turbulence model is employed to estimate the eddy viscosity. Experimental apparatus with an open-loop facility is set up for measuring the pump performance. Pump performance, efficiency and pressure, obtained from numerical simulation are validated by comparison with the results of experiments. Throughout the shape optimization of the pump impeller at the operating flow condition, the pump efficiency is successfully increased by 3 percent compared to the reference pump. It is noted that the pressure increase of the optimum pump is mainly caused by higher momentum force generated inside blade passage due to the optimal blade shape. Comparisons of pump internal flow on the reference and optimum pump are also investigated and discussed in detail.

  16. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    R.K. Johnson

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.

  17. Effect of pumping chamber on performance of non-overload centrifugal pump

    Institute of Scientific and Technical Information of China (English)

    谷云庆; 吴登昊; 牟介刚; 蒋兰芳; 代东顺; 施瀚昱; 郑水华

    2015-01-01

    In order to specify the characteristics of un-overloaded centrifugal pumps, the IH100-65-200 pump was chosen as the model pump. Different calculation models for centrifugal pumps were established under different pumping chamber sectional parameters. In the numerical simulation of the centrifugal pumps flow field, the shaft power, head, efficiency, and the changes of the internal flow field under different sectional areas and sectional shapes were studied with the RNGk−εturbulence model, and the influence of the pumping chamber section characteristics of the non-overloaded centrifugal pumps were analyzed. The results show that sectional areas have a significant impact on the non-overload characteristics of centrifugal pumps. The shaft power and head of centrifugal pump are increasing with a lager sectional area, by which the gradient of head curves decreases. The efficiency is improved under a large flow rate condition, but the head and the efficiency are reduced at a small flow rate. It is also observed that the sectional shapes have less influence on the shaft power, the hydraulic performance and flow field characteristics of a centrifugal pump.

  18. Bearing problems’ effects on the dynamic performance of pumping stations

    Directory of Open Access Journals (Sweden)

    Mostafa A. Abu-Zeid

    2013-09-01

    Pumping stations use large number of bearings with different types and applications. These bearings have a clear effect on the performance and efficiency of the pumps. Pump bearings in the arid regions are greatly affected by temperature, water quality, lubricants, and maintenance operations. This research focuses on analysis of damaged rolling element bearings of pumping system. The objective of the research is to enhance and control dynamic performance of pumping stations by avoiding damage and failure of bearings. The research proves that damaged bearings generate periodic, non-periodic, and transient forces causing high amplitude of vibration at high frequencies and increasing energy consumption. Bearing faults increase vibration level 85%, where power consumption increases 14% and pump efficiency decreases 18%. It is very important to take care of bearings during installation, alignment, balancing, and maintenance to assure safe and efficient pump operation for long period. As pump efficiency decreases, water power decreases and/or consumed power increases affecting water distribution and management system. Bearing faults break pumping system for long period affecting irrigation system. Optimum operation of pumping stations helps to save and manage water requirement for development and extension projects in arid regions. The measurements are performed on full scale model in the field, which proves reliable results on similar pumping stations.

  19. Effects of Crust Ingestion on Mixer Pump Performance in Tank 241-SY-101: Workshop Results

    Energy Technology Data Exchange (ETDEWEB)

    Brennen, C.E.; Stewart, C.W.; Meyer, P.A.

    1999-10-20

    In August 1999, a workshop was held at Pacific Northwest National Laboratory to discuss the effects of crust ingestion on mixer pump performance in Hanford Waste Tank 241-SY-101. The main purpose of the workshop was to evaluate the potential for crust ingestion to degrade mixing and/or damage the mixer pump. The need for a previously determined 12-inch separation between the top of the mixer pump inlet and the crust base was evaluated. Participants included a representative from the pump manufacturer, an internationally known expert in centrifugal pump theory, Hanford scientists and engineers, and operational specialists representing relevant fields of expertise. The workshop focused on developing an understanding of the pump design, addressing the physics of entrainment of solids and gases into the pump, and assessing the effects of solids and gases on pump performance. The major conclusions are summarized as follows: (1) Entrainment of a moderate amount of solids or gas from the crust should not damage the pump or reduce its lifetime, though mixing effectiveness will be somewhat reduced. (2) Air binding should not damage the pump. Vibrations due to ingestion of gas, solids, and objects potentially could cause radial loads that might reduce the lifetime of bearings and seals. However, significant damage would require extreme conditions not associated with the small bubbles, fine solids, and chunks of relatively weak material typical of the crust. (3) The inlet duct extension opening, 235 inches from the tank bottom, should be considered the pump inlet, not the small gap at 262 inches. (4) A suction vortex exists at the inlet of all pumps. The characteristics of the inlet suction vortex in the mixer pump are very hard to predict, but its effects likely extend upward several feet. Because of this, the current 12-inch limit should be replaced with criteria based on actual monitored pump performance. The most obvious criterion (in addition to current operational

  20. Performance of a newly developed implantable centrifugal blood pump.

    Science.gov (United States)

    Tsukiya, T; Taenaka, Y; Tatsumi, E; Takano, H

    2001-01-01

    The performance of the newly developed implantable centrifugal blood pump was investigated in vitro. The pump was developed with the end goal of building a versatile system that includes a left ventricular assist system with an internal secondary battery or an implantable biventricular assist system with two implantable blood pumps. The hydrodynamic characteristics and efficiency of the blood pump were evaluated, and the mechanical damage to the blood caused by the blood pump was assessed through a hemolysis test using fresh goat blood. The pump could generate 120 mm Hg at a flow rate of 5 L/min and a motor speed of 2,500 rpm. The electric input power to the pump was approximately 5 watts under these working conditions. The hemolysis caused by the pump was a bit higher than that by the former model, but stayed within an acceptable range. Performance of the pump in vitro was considered sufficient for a left ventricular assist device, although further design improvement is necessary in terms of hemolysis and system efficiency to improve biocompatibility of the pump.

  1. Monitoring of small heat pumps using standardised tests in 2009; Monitoring von Klein-Waermepumpen mittels Normpruefungen 2009 - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Eschmann, M.

    2010-02-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the monitoring in 2009 of small heat pumps with heating powers up to 100 kW using standardised tests. The authors note that, in 2009, more heat pump tests were carried out than in the years before as a result of improved facilities and procedures. Also, after initial improvement in previous years, Coefficient of Performance (COP) values have deteriorated. This is, according to the authors, due to lower prices on the market. This means that heat pumps are built cost-optimised and are not developed to reach the maximum energetic efficiency. The tests carried out are listed and the results obtained are presented in graphical form and commented on. The EHPA/DACH quality label and the required COP values are reviewed.

  2. Experimental and Numerical Analysis of Performance Discontinuity of a Pump-Turbine under Pumping Mode

    Science.gov (United States)

    Zhang, X.; Burgstaller, R.; Lai, X.; Gehrer, A.; Kefalas, A.; Pang, Y.

    2016-11-01

    The performance discontinuity of a pump-turbine under pumping mode is harmful to stable operation of units in hydropower station. In this paper, the performance discontinuity phenomenon of the pump-turbine was studied by means of experiment and numerical simulation. In the experiment, characteristics of the pump-turbine with different diffuser vane openings were tested in order to investigate the effect of pumping casing to the performance discontinuity. While other effects such as flow separation and rotating stall are known to have an effect on the discontinuity, the present studied test cases show that prerotation is the dominating effect for the instability, positions of the positive slope of characteristics are almost the same in different diffuser vane opening conditions. The impeller has principal effect to the performance discontinuity. In the numerical simulation, CFD analysis of tested pump-turbine has been done with k-ω and SST turbulence model. It is found that the position of performance curve discontinuity corresponds to flow recirculation at impeller inlet. Flow recirculation at impeller inlet is the cause of the discontinuity of characteristics curve. It is also found that the operating condition of occurrence of flow recirculation at impeller inlet is misestimated with k-ω and SST turbulence model. Furthermore, the original SST model has been modified. We predict the occurrence position of flow recirculation at impeller inlet correctly with the modified SST turbulence model, and it also can improve the prediction accuracy of the pump- turbine performance at the same time.

  3. Performance Analysis Of Single-Pumped And Dual-Pumped Parametric Optical Amplifier

    Directory of Open Access Journals (Sweden)

    Sandar Myint

    2015-06-01

    Full Text Available Abstract In this study we present a performance analysis of single-pumped and dual- pumped parametric optical amplifier and present the analysis of gain flatness in dual- pumped Fiber Optical Parametric Amplifier FOPA based on four-wave mixing FWM. Result shows that changing the signal power and pump power give the various gains in FOPA. It is also found out that the parametric gain increase with increase in pump power and decrease in signal power. .Moreover in this paper the phase matching condition in FWM plays a vital role in predicting the gain profile of the FOPAbecause the parametric gain is maximum when the total phase mismatch is zero.In this paper single-pumped parametric amplification over a 50nm gain bandwidth is demonstrated using 500 nm highly nonlinear fiber HNLF and signal achieves about 31dB gain. For dual-pumped parametric amplification signal achieves 26.5dB gains over a 50nm gain bandwidth. Therefore dual-pumped parametric amplifier can provide relatively flat gain over a much wider bandwidth than the single-pumped FOPA.

  4. The Performance test of Mechanical Sodium Pump with Water Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang [SAM JIN Industrial Co. LTD., Chunan (Korea, Republic of)

    2015-10-15

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  5. Computer monitors drilling performance

    Energy Technology Data Exchange (ETDEWEB)

    1984-05-01

    Computer systems that can monitor over 40 drilling variables, display them graphically, record and transmit the information have been developed separately by two French companies. The systems, Vigigraphic and Visufora, involve the linking of a master computer with various surface and downhole sensors to measure the data on a real-time (as experienced) basis and compute the information. Vigigraphic is able to produce graphic displays grouped on four screens - drilling, tripping, geological and mud data. It computes at least 200 variables from the sensor readings, and it can store over 100 variables. Visufora allows the operator to group the drilling variables as desired. It can monitor and analyze surface and downhole parameters. The system can be linked with MWD tools. Twenty channels of input are assigned to surface values and the remaining 20 channels can be used to monitor downhole instrumentation.

  6. Performance and Characteristics of Heat Pump Clothes Drier

    Science.gov (United States)

    Ambarita, H.; Nasution, D. M.; Gunawan, S.; Nasution, A. H.

    2017-03-01

    In this paper, a study of clothes drying using a heat pump drier has been carried out. The objective is to examine the performance and drying characteristics of the heat pump clothes dryer. The result of performances and drying characteristics were compared with waste heat drying system of split-type residential air conditioner (RAC). A drying chamber with volume 1 m3 integrated with heat pump component had been designed and fabricated. The heat pump operated by vapor compression cycle with power input of 800W and refrigerant R22 as a working fluid. The clothes dried made of pure cotton with initial weight varied from 3.00 kg, 5.25 kg, and 6.38 kg, respectively. The results shown that the drying time and drying rate of heat pump drier are faster than waste heat drying system. The average total performance of heat pump clothes drier is 6.56. On the other hand, SMER which is obtained 1.492 kg/kWh. These values are lower than the SMER of waste heat drying system which shown the average value of 2.492 kg/kWh. In the case of drying clothes, waste heat drying of RAC shows a better performance in comparison with heat pump drying system.

  7. Automated Web-based Monitoring of a Pump and Treat System at the Hanford Site

    Science.gov (United States)

    Webber, W.; Versteeg, R.; Richardson, A.; Ankeny, M.; Gilmore, T.; Morse, J.; Thompson, M.

    2006-05-01

    Automated and autonomous monitoring of environmental conditions can be used to improve operational efficiency, verify remedial action decisions, and promote confidence in the monitoring process by making data and associated derived information readily accessible to regulators and stakeholders. Ultimately autonomous monitoring systems can reduce overall costs associated with regulatory compliance of performance and long- term monitoring. As part of a joint decision between DOE and the WA Department of Ecology to put on "cold standby" a pump and treat system that has been operating on the Department of Energy's Hanford site in Washington State since 1995, a web site was developed to display the automated water level network around the pump and treat system. The automated water level network consists of nineteen wells with water level transducers and temperature and conductivity probes for selected wells. Data from this network will be used to evaluate the impacts of the pump-and-treat system and the response of the aquifer to shutdown of the system. The website will provide access to data from the automated network along with additional information pertaining to the shutdown of the pump and treat system to the various stakeholders in a convenient and timely fashion. This will allow the various stakeholders to observe the impacts of the shutdown as the aquifer responds. There are future plans to expand this web-based data reporting platform to other environmental data that pertains to the various remedial actions planned at the Hanford site. The benefits of the web site application for monitoring and stewardship are: consistency of data processing and analyses with automated and on demand data and information delivery. The system and data access is password controlled and access to various data or fields can be restricted to specified users. An important feature is that the stakeholders have access to the data in near-real time providing a checks-and-balance system

  8. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo......An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  9. The effect of balance holes to centrifugal pump performance

    Science.gov (United States)

    Babayigit, O.; Ozgoren, M.; Aksoy, M. H.; Kocaaslan, O.

    2017-07-01

    The aim of this study is to analyze of a centrifugal pump with and without balance holes by using ANSYS-Fluent software. The pump used in the study is a commercial centrifugal pump consisting of two stages that is a model of Sempa Pump Company. Firstly, models of impeller, diffuser, suction and discharge sections of the centrifugal pump were separately drawn using Ansys and Solidworks software. Later, grid structures were generated on the flow volume of the pump. Turbulent flow volume was numerically solved by realizable k-є turbulence model. The flow analyses were focused on the centrifugal pump performance and the flow characteristics under different operational conditions with/without balance holes. Distributions of flow characteristics such as velocity and pressure distributions in the flow volume were also determined, numerically. The results of Computational Fluid Dynamics (CFD) with/without balance holes for the pump head and hydraulic efficiency on the design flow rate of 80 m3/h were found to be 81.5/91.3 m and 51.9/65.3%, respectively.

  10. Performance evaluation of heat pump dryer.

    Science.gov (United States)

    Pal, U S; Khan, M K

    2010-03-01

    A batch type heat pump assisted dehumidified air dryer was developed successfully with a medium range of temperatures (30-41°C) for safe drying of heat sensitive crops. Dehumidification system of the developed heat pump dryer (HPD) maintained the relative humidity (RH) of air entering the drying chamber below 40%. The inlet drying air temperature decreased during early hours of drying followed by rapid rise between the 2nd and 10th h, after which the temperature was almost stable. The RH of inlet and exhaust drying air increased initially and decreased subsequently with drying time as product became drier. The HPD was found to have a specific moisture extraction rate between 0.55 and 1.10 kg/kWh. Energy consumption for HPD for 24 h of operation was found less (4.48-5.05 kWh) than the hot air dryer (5.65-9.6 kWh) while operating under different drying conditions. Better quality dried sweet pepper (Capsicum annuum L.) was obtained in HPD owing to lower drying air temperature.

  11. Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Zerkowski Hans-Reinhard

    2006-05-01

    Full Text Available Abstract Background In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. Methods In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. Results A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. Conclusion Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.

  12. Performance Monitoring of Ships

    DEFF Research Database (Denmark)

    Hansen, Søren Vinther

    in the models have been identified. The models used in this work are based on empirical relations or based on regression analyses of model tests and full-scale trials. In order to achieve valid results the conditions where performance is estimated have to be inside the boundaries of the model. Filters have been...... and the ability of identifying the events that improves performance e.g. propeller and hull clean....

  13. Performance influence in submersible pump with different diffuser inlet widths

    Directory of Open Access Journals (Sweden)

    Qingshun Wei

    2016-12-01

    Full Text Available The diffuser inlet width is a key geometric parameter that affects submersible pump performance. On the basis of diffuser characteristic curve analyses, diffusers with different inlet widths and the same impeller were equipped to construct a submersible pump model through the use of AutoCAD software. The performance curves of the submersible pump, with six diffuser inlet widths, were obtained using computational fluid dynamics method. Simultaneously, the simulation results were tested with the experimental method presented in this article. The results show that the optimum value of the inlet width (b3 = 50 mm is larger than the experience-based one. With an increase in the inlet width, the optimum operating point of a submersible pump offsets to a larger flow rate. When the guide blade inlet width is approximately 40–55 mm, the submersible pump efficiency is relatively high, approximately 75.9%–83.7% capacity, and the flow rate is approximately 105–135 m3/h. The numerical results of submersible pump performance are higher than those of the test results; however, their change trends have an acceptable agreement with each other. The practical significance is supplied by changing the inlet width of the diffuser to expand the scope of use.

  14. Performance Prediction of Mechanical Pump in STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Han, Ji-Woong; Cho, Chungho; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Under a mid- and long-term nuclear R-D program, STELLA (Sodium Integral Effect Test Loop for Safety Simulation and Assessment) project is in progress in KAERI (Korea Atomic Energy Research Institute). In STELLA-1, the experiments for the evaluation of heat exchangers such as DHX (Decay heat exchanger) and AHX (Air heat exchanger) are being performed, and those for PHTS (Primary heat transport system) mechanical pump are being prepared. The detailed design of each component is based on that of a 600MWe demonstration reactor. The model pump installed in STELLA-1 was scaled down based on the scaling law. Since the reference reactor of STELLA-1 is a 600MWe pool type demonstration reactor, some design modifications were inevitable between pool type prototype pump and loop type model pump, such as outer case and inlet pipe. In this study performance evaluation on the model pump has been done by CFD methods. The Design modeler in ANSYS Workbench was utilized in modeling process. The computations were performed using the commercial code ANSYS CFX. The overall hydraulic behaviors in the model pump have been predicted at a steady state condition.

  15. Effect of Fluid Viscosity on Centrifugal Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nohhyeong [GS Caltex Corporation, Daejeon (Korea, Republic of)

    2013-06-15

    The characteristics of centrifugal pump performance according to fluid viscosity change were studied experimentally. A small volute pump with low specific speed was tested by changing the viscosity of an aqueous solution of sugar and glycerin, which is considered a Newtonian fluid. After finishing the test, the total head, shaft horsepower, and pump efficiency were compared with those of a water pump. The results are summarized as follows: when the fluid viscosity is increased, the shut-off head shows very little change but the total head decreases gradually as the flow increases, and this makes the H-Q curve leaning rapidly, and when the fluid viscosity is increased, the shaft horsepower shows very little change at the shutoff condition; however, the shaft horsepower increases more rapidly with an increase in the flow and viscosity.

  16. Performance of enlarged blood pump models with five different impellers.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In earlier studies, a 5:1 enlarged pump model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump had been constructed and the flow characteristics investigated. Although the results obtained were satisfactory, the medium used was air. A 5:1 enlarged pump model using water as the medium thus was designed and constructed. Five different impeller blade profile designs were used in the present study. By varying (1) the blade profile design: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed, the flow characteristics of the pump were investigated. It was found that the impeller with the higher number of blades, used in the forward and straight blade profiles, have the best performance.

  17. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norfolk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norfolk, CT (United States)

    2016-02-05

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  18. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.

    2013-08-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(tm), A.O. Smith Voltex(r), and Stiebel Eltron Accelera(r)300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  19. The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

    Science.gov (United States)

    Ulbricht, T. E.; Hemminger, J. A.

    1986-01-01

    The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 9000 rpm (938 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

  20. Thermal expansion pump for capillary high-performance liquid chromatography.

    Science.gov (United States)

    Tao, Qian; Wu, Qian; Zhang, Xiangmin

    2010-02-01

    A thermal expansion pump (TEP) based on a principle of liquid thermal expansion for capillary high-performance liquid chromatography has been developed. The novel pump is capable of generating a continuous flow at high pressure for constant and stable delivery of binary solvents from nanoliters to microliters per minute without splitting. Theoretical equations for controlling fluidic output of this pump have been established and validated by a series of experiments. Factors affecting flow rate, such as density discrepancy, liquid compressibility, and mass loss in output, were taken into account. An assembly of the pump system employing two groups of thermal expansion pumps (TEPs) working in turns were fabricated, and a controlling strategy for the pump system to maintain a continuous delivery without pressure fluctuation even at switching points was also developed. Both isocratic and gradients of binary solvent delivery by the TEPs were performed. Reproducibility and standard deviation at different flow rates were determined. A capillary high-performance liquid chromatography (micro-HPLC) system consisting of the TEPs, an injection valve, a homemade packed capillary column (20 cm x 100 microm i.d. with 5 microm C18), and a laser-induced fluorescence detector was set up, and sample separations were carried out. Results of RSD = 4% for flow and RSD = 2% for retention times at 500 nL/min were achieved. Such a pump system has almost no moving parts except for the solvent switches. Its overall costs of manufacture and running are very low. It is proven that the TEPs system has great potential and competitive capabilities in capillary liquid chromatography.

  1. Monitoring and data acquisition system for supervision of a photovoltaic pumping; Sistema de monitoramento e aquisicao de dados para supervisao de uma planta de bombeamento fotovoltaico

    Energy Technology Data Exchange (ETDEWEB)

    Juca, S.; Brito, F. [Instituto Federal de Educacao, Ciencia e Tecnologia do Ceara (IFCE), Maracanau, CE (Brazil)], Emails: sandrojuca@ifce.edu.br, fabio@ifce.edu.br; Carvalho, P. [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Dept. de Engenharia Eletrica], Email: carvalho@dee.ufc.br

    2009-07-01

    The development of a micro controlled monitoring system and data acquisition of low cost applied to a pumping plant PV without batteries is described. The results obtained in order to evaluate the system developed and predict the best times to drive the pumps and optimize plant efficiency is also analyzed. Voltage and pressure measures were done for two days in a pump powered by five photovoltaic solar panels arranged in parallel. The system of monitoring and developed data acquisition was set to perform tension and pressure readings every minute on the pump and store the average of these data in an external memory each 10 minutes. A software that monitoring and supervising that perform, via the interface USB, reading the data stored in external memory, records in a database, and builds charts with tension and pressure from the photovoltaic pumping was developed.

  2. Domestic heat pumps in the UK. User behaviour, satisfaction and performance

    Energy Technology Data Exchange (ETDEWEB)

    Caird, S.; Roy, R.; Potter, S. [Design Innovation Group, Dept. Design, Development, Environment and Materials, Faculty of Mathematics, Computing and Technology, The Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2012-08-15

    Consumer adoption of microgeneration technologies is part of the UK strategy to reduce carbon emissions from buildings. Domestic heat pumps are viewed as a potentially important carbon saving technology, given the ongoing decarbonisation of the electricity supply system. To address the lack of independent evaluation of heat pump performance, the Energy Saving Trust undertook the UK's first large-scale heat pump field trial, which monitored 83 systems in real installations. As part of the trial, the Open University studied the consumers' experience of using a domestic heat pump. An in-depth user survey investigated the characteristics, behaviour, and satisfactions of private householders and social housing residents using ground source and air source heat pumps for space and/or water heating, and examined the influence of user-related factors on measured heat pump system efficiency. The surveys found that most users were satisfied with the reliability, heating, hot water, warmth and comfort provided by their system. Analysis of user characteristics showed that higher system efficiencies were associated with greater user understanding of their heat pump system, and more continuous heat pump operation, although larger samples are needed for robust statistical confirmation. The analysis also found that the more efficient systems in the sample were more frequently located in the private dwellings than at the social housing sites and this difference was significant. This is explained by the interaction between differences in the systems, dwellings and users at the private and social housing sites. The implications for heat pump research, practice and policy are discussed.

  3. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    Energy Technology Data Exchange (ETDEWEB)

    Lubliner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States); Hales, David [Washington State Univ., Pullman, WA (United States); Kunkle, Rick [Washington State Univ., Pullman, WA (United States); Gordon, Andy [Washington State Univ., Pullman, WA (United States); Spencer, Melinda [Washington State Univ., Pullman, WA (United States)

    2016-02-23

    This final Building America Partnership report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing.

  4. Design method of water jet pump towards high cavitation performances

    Science.gov (United States)

    Cao, L. L.; Che, B. X.; Hu, L. J.; Wu, D. Z.

    2016-05-01

    As one of the crucial components for power supply, the propulsion system is of great significance to the advance speed, noise performances, stabilities and other associated critical performances of underwater vehicles. Developing towards much higher advance speed, the underwater vehicles make more critical demands on the performances of the propulsion system. Basically, the increased advance speed requires the significantly raised rotation speed of the propulsion system, which would result in the deteriorated cavitation performances and consequently limit the thrust and efficiency of the whole system. Compared with the traditional propeller, the water jet pump offers more favourite cavitation, propulsion efficiency and other associated performances. The present research focuses on the cavitation performances of the waterjet pump blade profile in expectation of enlarging its advantages in high-speed vehicle propulsion. Based on the specifications of a certain underwater vehicle, the design method of the waterjet blade with high cavitation performances was investigated in terms of numerical simulation.

  5. Influence of guide vane setting in pump mode on performance characteristics of a pump-turbine

    Science.gov (United States)

    Li, Deyou; Wang, Hongjie; Nielsen, Torbjørn K.; Gong, Ruzhi; Wei, Xianzhu; Qin, Daqing

    2016-11-01

    Performance characteristics in pump mode of pump-turbines are vital for the safe and effective operation of pumped storage power plants. They are resultant of Euler head (power input) and hydraulic losses (power dissipation). In this paper, 3-D steady simulations were performed under 13mm, 19mm and 25mm guide vane openings (GVOs). Three groups of operating points under the three GVOs were chosen based on experimental validation to investigate the influence of guide vane setting on flow patterns upstream and downstream. Analysed results show that, the guide vane setting will obviously change the flow pattern downstream, which in turn influences the flow upstream. It shows a strong effect on hydraulic losses in guide and stay vanes. In addition, at the large part load conditions, the change of GVO will increase the relative flow angle at the runner outlet. As a consequence, it decreases the Euler head. However, at other operating conditions, it only has a little influence on Euler head. Flow patterns in pump mode are very dependent on the GVO and discharge.

  6. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  7. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  8. Overall control and monitoring systems for pumped storage plants

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, B.; Cvetko, H.

    1982-01-01

    Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.

  9. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

    Science.gov (United States)

    Leme, Juliana; Fonseca, Jeison; Bock, Eduardo; da Silva, Cibele; da Silva, Bruno Utiyama; Dos Santos, Alex Eugênio; Dinkhuysen, Jarbas; Andrade, Aron; Biscegli, José F

    2011-05-01

    A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.

  10. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  11. Improving the monitoring of quantitative conditions of peacetime fuel stocks at pumping stations

    Directory of Open Access Journals (Sweden)

    Slaviša M. Ilić

    2011-04-01

    Full Text Available The paper has solved the problem of optimizing the existing inefficient and irrational system of the quantitative monitoring of the situation in peacetime fuel supplies at the pumping stations in the Army of Serbia. A study of existing organizational forms, military pumping stations as well as civilian ones, was carried out. Based on the completion of the survey by competent persons in the military, the methods of expert evaluation and the obtained quantitative indicator of the tested models, a multicriteria optimization was performed in order to select the optimal model. The optimization of the existing models, in terms of efficiency and economy, would be the rationalization and modernization - automation of military capacity and greater reliance on automated civilian pumping stations. Introduction Within the framework of the undergoing reform of the Serbian Army and in order to reduce the total costs, it is necessary to optimize the existing supply system that is technologically outdated, inefficient and uneconomic. The problem of research in this paper is reduced to the selection of an optimal model of the quantitative monitoring of the state of peacetime stocks of fuel at the pumping stations in the Serbian Army, in order to ensure economical operation and efficient monitoring of available and issued quantities, aiming at better decision making and management in the supply system as well as at achieving faster system response, with greater reliance on government logistics. Organization of work and monitoring the fuel quantitative status at pumping stations The existing system of monitoring the quantitative state of fuel pumping stations in the Army of Serbia has the following disadvantages: getting unreliable data, due to outdated equipment for fuel handling and measuring equipment, and manual collection of data; creation of unauthorized shortages (due to subjective human error or deception; inadequate engagement of respective material and

  12. THE CALCULATION OF THE PERFORMANCE PARAMETERS OF PUMPING EQUIPMENT AND PIPING NETWORK OF WATER SUPPLY AND RECLAMATION PUMPING STATIONS

    Directory of Open Access Journals (Sweden)

    Rahnyanskaya O. I.

    2015-06-01

    Full Text Available The calculation of pumping equipment and piping network parameters is presented. The method of cutting impeller pump diameter for optimal performance of pump unit with piping system on efficiency value is shown. The case of operating the distribution network and pumping station with three pump units D1250-25 is considered. Procedure of construction of loss-of-head curves in pipes, determination of the actual operating parameters of a single pump unit, selection of pump impeller diameter for essentials is indicated. Four points for graphing such curves are presented. According to the first point the whole network is divided into sections with suction, pressure main pipelines and pipelines with changing water flow compared with the previous ones. The second point involves definition of the electrical resistivity of each site. The resistance of network analyzer is determined in the third point, the loss-of -head of the whole network is determined in the fourth point. The article presents the scheme of pumping station with three pump units connected in parallel and a distribution network (Figure1, loss-of-head curves in pipes regardless the number of working pumps (Figure 2, the order of constructing three loss-of-head curves with operating one, two and three pumps with normal and cut pump impeller diameter (Figure 3 , the order of determination of the actual parameters of pump work characteristics according to combined characteristics of normal and cut pump impeller diameter ( Figure 4 In conclusion, it is stated that the question of proper definition of actual parameters of pumps and the support of these parameters in optimal mode remains open due to the lack of proper methods of constructing loss-of-head curves pipeline. Every similar calculation is preliminary and should be carried out in field conditions

  13. Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Loomis, H.

    2015-06-01

    Transformations, Inc. has extensive experience building their high performance housing at a variety of Massachusetts locations, in both a production and custom home setting. The majority of their construction uses mini-split heat pumps (MSHPs) for space conditioning. This research covered the long-term performance of MSHPs in Zone 5A; it is the culmination of up to 3 years' worth of monitoring in a set of eight houses. This research examined electricity use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions. The use of simplified space conditioning distribution (through use of MSHPs) provides significant first cost savings, which are used to offset the increased investment in the building enclosure.

  14. Performance of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Silvestri, John J.; Scaringe, Robert P.; Grzyll, Lawrence R.

    1990-01-01

    The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

  15. Performance of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Silvestri, John J.; Scaringe, Robert P.; Grzyll, Lawrence R.

    1990-01-01

    The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

  16. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    Energy Technology Data Exchange (ETDEWEB)

    Lubliner, Michael [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Howard, Luke [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Hales, David [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Kunkle, Rick [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Gordon, Andy [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program; Spencer, Melinda [Building America Partnership for Improved Residential Construction, Olympia, WA (United States). Washington States Univ. Energy Program

    2016-02-18

    The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP)research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH. Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

  17. A modal approach for vibration analysis and condition monitoring of a centrifugal pump

    Directory of Open Access Journals (Sweden)

    Ramana Podugu

    2011-08-01

    Full Text Available The modal analysis of the centrifugal pump and its assembly is performed using FEM technology. The mathematical model and FEA model are built for the original centrifugal casing and simulation is made to find the pump natural frequencies. The first ten natural frequencies were compared to pump operating speed and their multiples up to pump vane passing frequency as per HIS (Hydraulic Institute Standards -9.6.4-2000 guidelines. In the original design, the first natural frequency in vertical direction of the pump is found to be thecause for resonance at the first multiple speed of the pump. The first natural frequency of the original model was found to be 63.25 Hz which is very close to 62.5 Hz of the pump operating speed by a margin of 1.2%. As per HIS clause 9.6.4.4, the first natural frequency should be 10% above or below the pump operating speed. Finally, the model was modified by stiffening the pump pedestals and again FEA analysis was carried out to find the natural frequencies. As a result of modification in design, the first natural frequency was increased to 74.31Hz which is above 10% the pump operating speed i.e., 62.5 Hz. Hence, the results of the modified design aresatisfied with HIS clause. The results also show that the higher the stiffness of the pump, higher the natural frequency is.

  18. Monitoring of aquifer pump tests with Magnetic Resonance Sounding (MRS)

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, Esben; Bauer-Gottwein, Peter

    2009-01-01

    Magnetic Resonance Sounding (MRS) can provide valuable data to constrain and calibrate groundwater flow and transport models. With this non-invasive geophysical technique, field measurements of water content and hydraulic conductivities can be obtained. We developed a hydrogeophyiscal forward met...... to pump tests in which a partially penetrating pumping well is used, because the limited drawdown around the extraction well causes smaller changes in received signal compared to a fully penetrating well....... method, which calculates the MRS-signal generated by an aquifer pump test. A synthetic MRS-dataset was subsequently used to determine the hydrogeological parameters in an inverse parameter estimation approach. This was done for a pump test with a partially and fully penetrating well. With the MRS data we...... were able to retrieve the hydrogeological parameters of the aquifer. However, the differences in MRS signal in time, when the instrument is positioned on top of the extraction well, were small compared to the electromagnetic noise. This could especially limit the applicability of the MRS technique...

  19. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G; Salapura, Valentina

    2014-12-02

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  20. Feasibility of a TinyPump system for pediatric CPB, ECMO, and circulatory assistance: hydrodynamic performances of the modified pump housing for implantable TinyPump.

    Science.gov (United States)

    Yokoyama, Naoyuki; Suzuki, Masaaki; Hoshi, Hideo; Ohuchi, Katsuhiro; Fujimoto, Tetsuo; Takatani, Setsuo

    2007-01-01

    The TinyPump is a miniature centrifugal blood pump with an extremely small priming volume of 5 ml, allowing blood transfusion free cardiopulmonary bypass as well as extracorporeal membrane oxygenation in pediatric patients. In this study, a new pump housing with the angled inlet port (25 degrees toward impeller center with respect to the flow axis) was designed to optimize the pump displaced volume and to extend the application of the TinyPump to implantable support The fluid dynamic performance analysis revealed that the head pressure losses increased from 3 to 17 mm Hg in comparison with straight port design as the pump rotational speed increased from 2,000 to 4,000 rpm. This was probably caused by perturbed flow patterns at the site of the inlet bent port area and streamline hitting the off-center of the impeller. No significant effect on pumping efficiency was observed because of modification in inlet port design. Modification in the inflow and outflow port designs together with the drive mechanism reduces the height of the pump system, including the motor, to 27 mm yielding the displaced volume of 68 ml in comparison with 40 mm of the paracorporeal system with the displaced volume of 105 ml. Further analysis in terms of hemolytic as well as antithrombogenic performance will be carried out to finalize the housing design for the implantable version of the TinyPump.

  1. Performance analysis of photovoltaic based submersible water pump

    Directory of Open Access Journals (Sweden)

    Shiv Lal

    2013-04-01

    Full Text Available The performance of a photovoltaic (PV array based water pumping system situated at Kota Rajasthan (25.18 N and 75.83 E, India has been studied. A 2hp DC motor with 2200W (10 panels of each 225W have been used for discharge 30 m water head. The maximum discharge logged 163litre/minute between 11AM to 2PM at PV power output between 75 to 85W/m2and the system is operating approximately 8 hours in the of November of the winter season. The full day discharge has found 70995litre and it is more than the average discharge given by the manufacturer at 50m depth. It is revealed that PV array based water pumping system is suitable and feasible option for off-grid and drip irrigation system like the interior area of Kota, where clear sky days are more than 250 in a year.

  2. Performance Monitoring in Transparent Reconfigurable WDM Networks

    Institute of Scientific and Technical Information of China (English)

    Chun-Kit.Chan; Frank; Tong

    2003-01-01

    This paper classifies and surveys different approaches proposed for performance monitoring, in particular the optical signal-to-noise ratio (OSNR) monitoring, in transparent reconfigurable WDM networks. Some considerations for future monitoring schemes are discussed.

  3. Design of Reactor Coolant Pump Seal Online Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Ah, Sang Ha; Chang, Soon Heung [KAIST, Daejeon (Korea, Republic of); Lee, Song Kyu [Korea Power Engineering Co., Yongin (Korea, Republic of)

    2008-05-15

    As a part of a Department of Korea Power Engineering Co., (KOPEC) Project, Statistical Quality Control techniques have been applied to many aspects of industrial engineering. An application to nuclear power plant maintenance and control is also presented that can greatly improve plant safety. As a demonstration of such an approach, a specific system is analyzed: the reactor coolant pumps (RCPs) and the fouling resistance of heat exchanger. This research uses Shewart X-bar, R charts, Cumulative Sum charts (CUSUM), and Sequential Probability Ratio Test (SPRT) to analyze the process for the state of statistical control. And the Control Chart Analyzer (CCA) has been made to support these analyses that can make a decision of error in process. The analysis shows that statistical process control methods can be applied as an early warning system capable of identifying significant equipment problems well in advance of traditional control room alarm indicators. Such a system would provide operators with enough time to respond to possible emergency situations and thus improve plant safety and reliability. RCP circulates reactor coolant to transfer heat from the reactor to the steam generators. RCP seals are in the pressure part of reactor coolant system, so if it breaks, it can cause small break LOCA. And they are running on high pressure, and high temperature, so they can be easily broken. Since the reactor coolant pumps operate within the containment building, physical access to the pumps occurs only during refueling outages. Engineers depend on process variables transmitted to the control room and through the station's data historian to assess the pumps' condition during normal operation.

  4. Performance indices for pumping stations in irrigated rice fields

    Directory of Open Access Journals (Sweden)

    Luciana Marini Köpp

    2016-08-01

    Full Text Available ABSTRACT: Performance indices can be used as indices of energy use in irrigation systems. Pumping stations (PSs are elements that require energy for irrigation of rice fields by conventional flood irrigation. Interplay of physical, hydraulic, and electrical parameters generates indices that determine the performance in the diagnosis of PSs, operation, and projects for new sets. In this study, it was proposed and classified performance indices for PSs in rice fields, focusing on the efficient use of energy. The study was carried out through an investigation of 160 PSs in operation, located at the western border of Rio Grande do Sul, Brazil, which constituted an actual field situation. Next, PSs were optimized in relation to the selection of a piping system, using the lowest total cost, the choice of pump, and motors with better performance for the necessary situation as criteria. Results provided nine indices that classified the performance as "excellent", "very good", "good", "poor", and "very poor", which allowed the assessment of projects and the diagnosis of PSs.

  5. Performance optimization of grooved slippers for aero hydraulic pumps

    Institute of Scientific and Technical Information of China (English)

    Chen Juan; Ma Jiming; Li Jia; Fu Yongling

    2016-01-01

    A computational fluid dynamics (CFD) simulation method based on 3-D Navier–Stokes equation and Arbitrary Lagrangian–Eulerian (ALE) method is presented to analyze the grooved slip-per performance of piston pump. The moving domain of grooved slipper is transformed into a fixed reference domain by the ALE method, which makes it convenient to take the effects of rotate speed, body force, temperature, and oil viscosity into account. A geometric model to express the complex structure, which covers the orifice of piston and slipper, vented groove and the oil film, is constructed. Corresponding to different oil film thicknesses calculated in light of hydrostatic equilibrium theory and boundary conditions, a set of simulations is conducted in COMSOL to analyze the pump characteristics and effects of geometry (groove width and radius, orifice size) on these characteristics. Furthermore, the mechanics and hydraulics analyses are employed to validate the CFD model, and there is an excellent agreement between simulation and analytical results. The simulation results show that the sealing land radius, orifice size and groove width all dramatically affect the slipper behavior, and an optimum tradeoff among these factors is conducive to optimizing the pump design.

  6. Performance optimization of grooved slippers for aero hydraulic pumps

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2016-06-01

    Full Text Available A computational fluid dynamics (CFD simulation method based on 3-D Navier–Stokes equation and Arbitrary Lagrangian–Eulerian (ALE method is presented to analyze the grooved slipper performance of piston pump. The moving domain of grooved slipper is transformed into a fixed reference domain by the ALE method, which makes it convenient to take the effects of rotate speed, body force, temperature, and oil viscosity into account. A geometric model to express the complex structure, which covers the orifice of piston and slipper, vented groove and the oil film, is constructed. Corresponding to different oil film thicknesses calculated in light of hydrostatic equilibrium theory and boundary conditions, a set of simulations is conducted in COMSOL to analyze the pump characteristics and effects of geometry (groove width and radius, orifice size on these characteristics. Furthermore, the mechanics and hydraulics analyses are employed to validate the CFD model, and there is an excellent agreement between simulation and analytical results. The simulation results show that the sealing land radius, orifice size and groove width all dramatically affect the slipper behavior, and an optimum tradeoff among these factors is conducive to optimizing the pump design.

  7. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  8. Development of a solenoid pumped in situ zinc analyzer for environmental monitoring

    Science.gov (United States)

    Chapin, T.P.; Wanty, R.B.

    2005-01-01

    A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 ??g L-1. Precision was 5-10% relative standard deviation (R.S.D.) below 100 ??g L-1, improving to 1% R.S.D. at 1000 ??g L-1. The linear range extended from 30 to 3000 ??g L-1. In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector. ?? 2005 Elsevier B.V. All rights reserved.

  9. High Performance Small Optically Pumped Caesium Beam Frequency Standard

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jian-Wei; YANG Dong-Hai

    2007-01-01

    An experiment of a high performance small optically pumped caesium (Cs) beam frequency standard is reported. An extended cavity diode laser works as the probing laser, of which the frequency is stabilized by the Zeeman modulation method. The running parameters of the frequency standard are dynamically optimized via digital servo electronics. The experimental setup improves the frequency stability up to 1.8 × 10-12 atτ= 1 s and about 1.0 × 10~13 at τ= 105 s (Allan deviation).

  10. Demand Response Performance of GE Hybrid Heat Pump Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Parker, Graham B.; Petersen, Joseph M.; Baechler, Michael C.

    2013-07-01

    This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

  11. Influence of Splitter Blades on the Cavitation Performance of a Double Suction Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Wei Yang

    2014-04-01

    Full Text Available In order to study the influence of splitter blades on double suction centrifugal pumps two impellers with and without splitter blades were investigated numerically and experimentally. Three-dimensional turbulence simulations with and without full cavitation model were applied to simulate the flow in the two pumps with different impellers. The simulation results agreed with the experiment results and the internal flows were analyzed. Both the numerical and experimental results show that by adding splitter blades the hydraulic performance and the cavitation performance of the pump are improved. The pump efficiency is increased especially at high flow rate condition. The pump high efficiency area is extended dramatically. At the same time since the splitter blades share some part of the blade loading, the pump critical NPSH value is decreased. Obvious pressure increase and velocity decrease at blade suction surface near leading edge were observed in the pump impeller with splitter blades. And the pump cavitation performance was improved consequently.

  12. DEVELOPMENT OF A HIGH PERFORMANCE COLD CLIMATE HEAT PUMP

    Energy Technology Data Exchange (ETDEWEB)

    Horton, W. Travis [Purdue University; Groll, Eckhard A. [Purdue University; Braun, James E. [Purdue University

    2014-06-01

    The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested

  13. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed.

  14. Cracking resistance performance of super vertical-distance pumped SFRC

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The mix ratio of steel fiber reinforced concrete(SFRC)was optimized using the principles that workability must meet the pumping demand and anti-cracking performance should be optimal.The effect of SFRC on the initial cracking load,the ultimate load and the crack width of the reinforced concrete (RC) member were analyzed in this paper.It was found that the admixture had good preservation of moisture and adhesion and the fibers distributed homogeneously in one hour out of the machine.According to the pumping results,the SFRC could be pumped vertically up to 306 m.Based on the standard computation formula of cracks,the maximum crack width of an RC member with 0.8% steel fiber (by volume) is about 32% lower than that of standard RC member.Through an experimental research on full-scale model tests for the steel and concrete composite anchorage zone on a pylon,the SFRC not only remarkably increases the crack resistance and the ultimate load,but the initial load also improves 33% approximately.It is also indicated that plastic shrinkage cracking of SFRC in which volume fraction of steel fibers is 0.8% can be restrained obviously and the unrestrained drying shrinkage can be diminished by about 50% at early age.The results confirmed that the SFRC can lessen the shrinkage crack of concrete and enhance markedly the direct tensile strength.Therefore,the SFRC can solve the key question of crack resistance for the anchorage zone of a bridge tower.

  15. Performance of a small wind powered water pumping system

    Science.gov (United States)

    Lorentz helical pumps (Henstedt-Ulzburg, Germany) have been powered by solar energy for remote water pumping applications for many years, but from October 2005 to March 2008 a Lorentz helical pump was powered by wind energy at the USDA-ARS Conservation and Production Research Laboratory (CPRL) near ...

  16. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  17. On-line PWR RHR pump performance testing following motor and impeller replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiMarzo, J.T.

    1996-12-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump`s `B` impeller. The spare was installed into the `B` train. The motor had never been run in the system before. A pump performance test was developed to verify it`s operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the `B` Train showed performance well in excess of the minimum required. The motor that was originally in the `B` train was similarly overhauled and equipped with `A` pump`s original impeller, re-installed in the `A` train, and tested. Analysis of the `A` train results indicate that the RHR pump`s performance was also well in excess of the vendors requirements.

  18. 5 CFR 430.306 - Monitoring performance.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors...

  19. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy

    DEFF Research Database (Denmark)

    Battelino, T; Conget, I; Olsen, B

    2012-01-01

    The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes.......The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes....

  20. Performance Assessment for Pump-and-Treat Closure or Transition

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Christian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Becker, Dave J. [U.S. Army Corps of Engineers Environmental and Munitions Center of Expertise, Huntsville, AL (United States); Lee, Michelle H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Nimmons, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-29

    A structured performance assessment approach is useful to evaluate pump-and-treat (P&T) groundwater remediation, which has been applied at numerous sites. Consistent with the U.S. Environmental Protection Agency’s Groundwater Road Map, performance assessment during remedy implementation may be needed, and should consider remedy optimization, transition to alternative remedies, or remedy closure. In addition, a recent National Research Council study examined groundwater remediation at complex contaminated sites and concluded that it may be beneficial to evaluate remedy performance and the potential need for transition to alternative approaches at these sites. The intent of this document is to provide a structured approach for assessing P&T performance to support a decision to optimize, transition, or close a P&T remedy. The process presented in this document for gathering information and performing evaluations to support P&T remedy decisions includes use of decision elements to distinguish between potential outcomes of a remedy decision. Case studies are used to augment descriptions of decision elements and to illustrate each type of outcome identified in the performance assessment approach. The document provides references to resources for tools and other guidance relevant to conducting the P&T assessment.

  1. Performance Analysis of Air-to-Water Heat Pump in Latvian Climate Conditions

    Science.gov (United States)

    Kazjonovs, Janis; Sipkevics, Andrejs; Jakovics, Andris; Dancigs, Andris; Bajare, Diana; Dancigs, Leonards

    2014-12-01

    Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being -20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the

  2. Performance evaluation of a transformerless multiphase electric submersible pump system

    Directory of Open Access Journals (Sweden)

    Ahmed A. Hakeem

    2014-08-01

    Full Text Available Using of low-voltage variable-frequency drive followed by a step-up transformer is the most preferable way to feed an electrical submersible pump motor. The existence of long feeder between the motor and drive systems usually causes over-voltage problems because of the travelling wave phenomenon, which makes the employment of filter networks on the motor or inverter terminals mandatory. The so-called boost-inverter inherently can solve this problem with filter-less operation as it offers a direct sinusoidal output voltage. As boost inverters have voltage boosting capability, it can provide a transformer-less operation as well. This study investigates the performance of a five-phase modular winding induction machine fed from a boost-inverter through a long feeder. A simulation study using a 1000 Hp system and experimental investigation on a 1 Hp prototype machine are used to support the presented approach.

  3. A simple, low-cost method to monitor duration of ground water pumping.

    Science.gov (United States)

    Massuel, S; Perrin, J; Wajid, M; Mascre, C; Dewandel, B

    2009-01-01

    Monitoring ground water withdrawals for agriculture is a difficult task, while agricultural development leads frequently to overexploitation of the aquifers. To fix the problem, sustainable management is required based on the knowledge of water uses. This paper introduces a simple and inexpensive direct method to determine the duration of pumping of a well by measuring the temperature of its water outlet pipe. A pumping phase is characterized by a steady temperature value close to ground water temperature. The method involves recording the temperature of the outlet pipe and identifying the different stages of pumping. It is based on the use of the low-cost and small-size Thermochron iButton temperature logger and can be applied to any well, provided that a water outlet pipe is accessible. The temperature time series are analyzed to determine the duration of pumping through manual and automatic posttreatments. The method was tested and applied in South India for irrigation wells using electricity-powered pumps. The duration of pumping obtained by the iButton method is fully consistent with the duration of power supply (1.5% difference).

  4. Performance of Gas-Engine Driven Heat Pump Unit

    Energy Technology Data Exchange (ETDEWEB)

    Abdi Zaltash; Randy Linkous; Randall Wetherington; Patrick Geoghegan; Ed Vineyard; Isaac Mahderekal; Robert Gaylord

    2008-09-30

    Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater

  5. Dynamic Performance of a Residential Air-to-Air Heat Pump.

    Science.gov (United States)

    Kelly, George E.; Bean, John

    This publication is a study of the dynamic performance of a 5-ton air-to-air heat pump in a residence in Washington, D.C. The effect of part-load operation on the heat pump's cooling and heating coefficients of performance was determined. Discrepancies between measured performance and manufacturer-supplied performance data were found when the unit…

  6. Performance Optimization of the Multi-Pumped Raman Optical Amplifier using MOICA

    Directory of Open Access Journals (Sweden)

    Mohsen Katebi Jahromi

    2016-08-01

    Full Text Available In order to achieve the best gain profile for multi pump distributed Raman amplifiers in Wavelength Division Multiplexing (WDM transmission systems, the power and wavelength of pumps, the type of pumping configuration and the number of pump signals are the most important factors. In this paper, using a Multi-Objective Imperialist Competition Optimization Algorithm (MOICA with lowest power consumption and lowest number of pumps, we propose the most uniform gain profile for two types of pumping configurations in S- band and compare the results. Considering the design conditions including the type of pumping configuration, fiber length, fiber type and number of pump signals and using the multi-objective algorithm, we propose a method which can be used to achieve a gain level in which the amplifier has the lowest power consumption and lowest gain ripple. According to this, we can design a powerful WDM transmission system by Distributed Raman Amplifier (DRA with a good performance and efficiency.

  7. Expert system for the diagnosis of the condition and performance of centrifugal pumps

    Energy Technology Data Exchange (ETDEWEB)

    Jantunen, E.; Vaehae-Pietilae, K.; Pesonen, K. [Technical Research Centre of Finland, Manufacturing Technology, Espoo (Finland)

    1997-12-31

    A brief description of the results of a study concerning the maintenance and downtime costs in Finnish pumping is given. The leakage of seals was found to be the fault that causes the highest downtime and maintenance costs. A small laboratory arrangement has been used to test the effectiveness of various condition monitoring methods. This information has been used in the development of a diagnostic expert system called CEPDIA, which can be used for diagnosing the condition of a pump and its components. The diagnosis is based on measuring results obtained from sensors and on information about maintenance actions carried out with the pump and its components. The principles of the CEPDIA expert system are described. A database is included in the system for handling and saving the measurement results, technical information on the pumps and maintenance actions carried out with the pumps. The diagnosis can also be based on vibration signature analysis, which is quite effective in determining which fault is the actual cause of malfunction of the pump or its components. CEPDIA can also be used to calculate of the efficiency of the electrical motor and the pump. CEPDIA has been tested in the diagnosis of 63 pumps. The average efficiency in pumping was less than 40 %, and more than 10 % of the pumps were pumping with less than 10 % efficiency. (orig.) 11 refs.

  8. The performance of a cryogenic pump for the two-phase flow condition

    OpenAIRE

    YAMADA, HITOSHI; WATANABE, Mitsuo; Hasegawa, Satoshi; Kamijo, Kenjiro; 山田, 仁; 渡辺, 光男; 長谷川, 敏; 上條, 謙二郎

    1985-01-01

    An experimental investigation was carried out in order to obtain the performance characteristics of a cryogenic pump under a two-phase flow condition. The experiment used an oxygen pump with an inducer and liquid nitrogen as the test fluid. The vapor volumetric fraction at the pump inlet was calculated with an assumption of a constant enthalpy process across an orifice which was used to generate the two-phase flow at the pump inlet. The results showed that the pump head rise did hardly decrea...

  9. Visual Intelligent Robot Performance Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a Visual Intelligent Robot Performance Monitor (VIRPM) that will help crew members maintain situation awareness of robot performance more...

  10. Monitoring the performance of incident management teams

    National Research Council Canada - National Science Library

    Conway, Geoff

    2016-01-01

    The Real Time Performance Monitoring Program operating in Victoria - tool available to agency leaders to understand the performance of their incident managers based on the context in which incident...

  11. Generalized Performance Characteristics of Refrigeration and Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Mahmoud Huleihil

    2010-01-01

    Full Text Available A finite-time generic model to describe the behavior of real refrigeration systems is discussed. The model accounts for finite heat transfer rates, heat leaks, and friction as different sources of dissipation. The performance characteristics are cast in terms of cooling rate (r versus coefficient of performance (w. For comparison purposes, various types of refrigeration/heat pump systems are considered: the thermoelectric refrigerator, the reverse Brayton cycle, and the reverse Rankine cycle. Although the dissipation mechanisms are different (e.g., heat leak and Joule heating in the thermoelectric refrigerator, isentropic losses in the reverse Brayton cycle, and limits arising from the equation of state in the reverse Rankine cycle, the r−w characteristic curves have a general loop shape. There are four limiting types of operation: open circuit in which both r and w vanish in the limit of slow operation; short circuit in which again r and w vanish but in the limit of fast operation; maximum r; maximum w. The behavior of the considered systems is explained by means of the proposed model. The derived formulae could be used for a quick estimation of w and the temperatures of the working fluid at the hot and cold sides.

  12. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily...... injections and baseline HbA1c was 8.9%. Due to pre-eclampsia, the child was born preterm, and had neonatal hypoglycemia. In the planning of the second pregnancy, insulin-pump therapy was initiated, resulting in an HbA1c of 6.8% in early pregnancy. Due to pre-eclampsia, the second child was born preterm......, but without neonatal morbidity. Before her third pregnancy, CGM-enabled insulin-pump therapy was introduced, and HbA1c was 6.4% in early pregnancy. The patient was satisfied with this therapy, pre-eclampsia did not occur, and the child was born at term without neonatal morbidity. CGM-enabled insulin-pump...

  13. Study on Performance and Internal Flow Condition of Mini Turbo-Pump

    Science.gov (United States)

    Shigemitsu, Toru; Fukutomi, Junichiro; Nasada, Ryoichi

    2010-06-01

    Mini turbo-pumps which have a diameter smaller than 100mm are utilized in many fields; automobile radiator pump, artificial heart pump, cooling pump for electric devices, washing machine pump and so on. And the needs for the mini turbo-pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini turbo-pump design is as simple as possible due to the limitation of the precision for manufacture. But the design method for the mini turbo-pump is not established because the internal flow condition for these small-sized fluid machineries is not clarified and conventional theory is not conductive for small-sized pumps because of the low Reynolds number and the size effects. Therefore, we started the research of the mini turbo-pump for the purpose of development of high performance mini turbo-pump with simple structure. As a first step of this research, mini turbo-pump with the 46mm rotor diameter was designed based on the conventional design method in order to clarify the problems for the application of conventional method for mini turbo-pump in details. The three dimensional steady numerical flow analysis was conducted with the commercial code (Fluent6.3). The numerical flow analysis was also performed under the condition with and without a tip clearance because the tip clearance influence on the performance and internal flow condition is extremely large for mini turbo-pumps. It was clarified from the numerical results that head of the mini turbo-pump at the designed point without the tip clearance satisfied the designed value head H = 1.2m and the efficiency is about η = 60% which is acceptable value for the centrifugal pump. On the other hand, head and efficiency decreased drastically with the increase of the tip clearance. The flow condition near the tip region was influenced by the leakage flow from the blade tip. And it is observed by the results of the total pressure distributions that the total

  14. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    . When the solar collectors are unable to supply the heat demand an auxiliary heat source is used. Heat pumps can generate this heat. Liquid/water heat pumps have better performance than air/water heat pumps in cold climates but requires installation of a tubing system for the cold side of the heat pump....... The tubes are typically placed in the ground, requires a significant land area and increase the installation cost. A new system design of a solar heating system with two storage tanks and a liquid/water heat pump is presented. The system consists of PVT collectors that generate both heat and electricity....... Heat from the collectors is transferred to a domestic hot water storage tank or to a cold storage tank, which is used as the source for the heat pump. When the heat pump charges the warm storage tank, heat is extracted from the cold storage tank, which then can be reheated by the PVT collectors...

  15. Numerical Investigation of the Performance of an Axial-Flow Pump with Tandem Blades

    Institute of Scientific and Technical Information of China (English)

    YU Zhi-yi; LIU Shu-yan; WANG Guo-yu

    2007-01-01

    The performance characteristics of an axial-flow pump with tandem blades are studied based on the numerical computations. The arrangement of the pump impellers is established through the analysis of velocity triangles. With the commercial computational fluid dynamics (CFD) software NUMECA, the turbulent flow in the tandem axial-flow pump is simulated in various flow conditions. The detail flow structure in the leading edge region of the rear impeller is described, and the i nfluence of the deflection angle of the rear blade on the head performance is studied. According to the simulation, the performance comparison is made between the tandem axial-flow pump and the conventional two-stage axial-flow pump with a uniform impeller size. Results of the study indicate that the tandem axial-flow pump can work in a wider range with high efficiency.

  16. Electro-pump Fault Diagnosis of Marine Ship by Vibration Condition Monitoring

    Directory of Open Access Journals (Sweden)

    Payman Salami

    2010-05-01

    Full Text Available The objective of this research is to investigate the correlation between vibration analysis and fault diagnosis. This was achieved by vibration analysis of an electro-pump of marine ship. The vibration analysis was initially run under regular interval during electro-pump life. Some series of tests were then conducted under the operating hours of stone crasher. Vibration data was regularly collected. The overall vibration data produced by vibration analysis was compared with previous data, in order to quantify the effectiveness of the results of vibration condition monitoring technique. Numerical data produced by vibration analysis were compared with vibration spectra in standard condition of healthy machine, in order to quantify the effectiveness of the vibration condition monitoring technique. The results of this paper have given more understanding on the dependent roles of vibration analysis in predicting and diagnosing machine faults.

  17. Performance of the distributed Brillouin sensor: Benefits and penalties due to pump depletion

    Science.gov (United States)

    Ravet, Fabien

    Disaster prevention in civil infrastructures requires the use of techniques that allow temperature and strain measurements in real time over lengths of a few meters to tens of kilometres. The distributed Brillouin sensor (DBS) technique has the advantage to combine all these characteristics. The sensing mechanism of the DBS involves the interaction of two counter-propagating lightwaves, the Stokes and the pump, in an optical fibre. Spatial information is obtained through time domain analysis. The sensing data are recorded from the measurement of the pump depletion. We explore the benefits and the drawbacks of this approach and show that there is a power range for which the sensing performances are optima. To achieve that goal, Brillouin fibre generator (BFG) and amplifier (BFA) were studied leading to the derivation of a threshold definition for the BFA, which is the configuration of the DBS. Within that context, numerical and analytical models describing the stimulated Brillouin scattering (SBS) interaction are introduced and validated experimentally. Even if pump depletion is carefully controlled, the Brillouin spectrum shape, and hence the sensor performance, still depend on the sensing parameters such as power, pulse and fibre characteristics. We use a signal processing method grounded in the physics of Brillouin scattering. An analytical approximation, valid for the optimum sensing region, reconstructs the Brillouin spectrum distribution from input sensing parameters and measured data. These data are obtained with a spectrum analysis methodology, based on three original tools: the Rayleigh equivalent criterion, the lengthstress diagram, and the spectrum form factors. This methodology has been successfully used on experimental spectra. The DBS and the signal processing approach were then used to monitor the structural changes in steel pipes and in a composite column, all subjected to heavy loads. The DBS measured the strain distribution of those structures

  18. Effect of Temperature Set-Back on Heat Pump Performance

    Science.gov (United States)

    1981-04-01

    This report documents an analysis which shows that energy savings and corresponding cost savings could be realized by employing set-back strategies dependent on location, heat pump capacity and amount of set-back. (Author)

  19. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  20. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  1. Development of the Floating Centrifugal Pump by Use of Non Contact Magnetic Drive and Its Performance

    Directory of Open Access Journals (Sweden)

    Mitsuo Uno

    2004-01-01

    Full Text Available This article focuses on the impeller construction, non contact driving method and performance of a newly developed shaftless floating pump with centrifugal impeller. The drive principle of the floating impeller pump used the magnet induction method similar to the levitation theory of the linear motor. In order to reduce the axial thrust by the pressure different between shroud and disk side, the balance hole and the aileron blade were installed in the floating impeller. Considering the above effect, floating of an impeller in a pump was realized. Moreover, the performance curves of a developed pump are in agreement with a general centrifugal pump, and the dimensionless characteristic curve also agrees under the different rotational speed due to no mechanical friction of the rotational part. Therefore, utility of a non contacting magnetic-drive style pump with the floating impeller was made clear.

  2. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten;

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily...... injections and baseline HbA1c was 8.9%. Due to pre-eclampsia, the child was born preterm, and had neonatal hypoglycemia. In the planning of the second pregnancy, insulin-pump therapy was initiated, resulting in an HbA1c of 6.8% in early pregnancy. Due to pre-eclampsia, the second child was born preterm......, but without neonatal morbidity. Before her third pregnancy, CGM-enabled insulin-pump therapy was introduced, and HbA1c was 6.4% in early pregnancy. The patient was satisfied with this therapy, pre-eclampsia did not occur, and the child was born at term without neonatal morbidity. CGM-enabled insulin...

  3. 5 CFR 430.207 - Monitoring performance.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.207 Section 430.207 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees §...

  4. Intelligent pump drives. Simulation, condition monitoring, fault diagnosis and energy efficiency; Intelligente Pumpenantriebe. Simulation, Condition Monitoring, Fehlerdiagnose und Energieeffizienz

    Energy Technology Data Exchange (ETDEWEB)

    Kleinmann, Stefan [Allweiler AG, Radolfzell (Germany); Leonardo, Domenico; Koller-Hodac, Agathe [Hochschule fuer Technik Rapperswil (Switzerland)

    2011-07-01

    The authors of the contribution under consideration report on an implementation of a simulation environment and a fault diagnostic system for an oil burner application. Using a modification of the application hardware, an additional increase in efficiency in an advanced control of pump drives is achieved. The properties of the combustion process are not affected adversely. All changes to the system can be investigated in simulations for feasibility and impact. Using the simulation model, a diagnostic system is brought up enabling a remote monitoring for example.

  5. Optical fiber grating vibration sensor for vibration monitoring of hydraulic pump

    Science.gov (United States)

    Zhang, Zhengyi; Liu, Chuntong; Li, Hongcai; He, Zhenxin; Zhao, Xiaofeng

    2017-06-01

    In view of the existing electrical vibration monitoring traditional hydraulic pump vibration sensor, the high false alarm rate is susceptible to electromagnetic interference and is not easy to achieve long-term reliable monitoring, based on the design of a beam of the uniform strength structure of the fiber Bragg grating (FBG) vibration sensor. In this paper, based on the analysis of the vibration theory of the equal strength beam, the principle of FBG vibration tuning based on the equal intensity beam is derived. According to the practical application of the project, the structural dimensions of the equal strength beam are determined, and the optimization design of the vibrator is carried out. The finite element analysis of the sensor is carried out by ANSYS, and the first order resonant frequency is 94.739 Hz. The vibration test of the sensor is carried out by using the vibration frequency of 35 Hz and the vibration source of 50 Hz. The time domain and frequency domain analysis results of test data show that the sensor has good dynamic response characteristics, which can realize the accurate monitoring of the vibration frequency and meet the special requirements of vibration monitoring of hydraulic pump under specific environment.

  6. Performance analysis of air source heat pump system for office building

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong Won; KIm, Yong Chan [Korea University, Seoul (Korea, Republic of); Chang, Young Soo [School of Mechanical System Engineering, Kookmin University, Seoul (Korea, Republic of)

    2016-11-15

    In this study, the performance of an air source heat pump system installed in a commercial building is analyzed using the developed heat pump performance model and building load simulation data of several regions in Korea. The performance test of an air source heat pump system with a variable speed compressor is tested to develop model that considers changes in the performance characteristics of the heat pump system under various operating conditions. The heat pump system is installed in an environmental chamber, and the experimental equipment is set up according to the manufacturer' specifications as well as the AHRI 1230 test specifications. The performance test conditions of the heat pump system are selected using a central composite design method, in which 29 points for each cooling and heating mode are selected. The developed performance model based on experimental data predicts experimental values with an error of ±5 %. Building cooling and heating loads in three regions in Korea are analyzed using TRNSYS software, which includes standard building and weather data from Seoul, Daejeon and Busan in Korea. The effects of outdoor air temperature and part load ratio on the performance and regional monthly average power consumption of the heat pump system are analyzed.

  7. Calculation method for the seasonal performance of heat pump compact units and validation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Wemhoener, C.; Dott, R.; Afjei, Th. [University of Applied Sciences Northwestern Switzerland, Institute of Energy in Buildings, Muttenz (Switzerland); Huber, H.; Helfenfinger, D.; Keller, P.; Furter, R. [University of Applied Sciences Lucerne (HTA), Test center HLKS, Horw (Switzerland)

    2007-02-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) takes a look at compact heat pump units that have been developed for the heating of low energy consumption houses built to MINERGIE or MINERGIE-P standards. These units, which combine the functions of space heating, domestic hot water preparation and ventilation in one unit are described. A testing procedure developed at the University of Applied Science in Lucerne, Switzerland, using a test rig for the measurement of the seasonal performance factor (SPF) is described. A calculation method based on temperature classes for the calculation of the SPF of combined heat pump systems for space heating and domestic hot water preparation that was developed by the Institute of Energy in Buildings at the University of Applied Sciences Northwestern Switzerland is examined. Two pilot plants allowing detailed field monitoring of two compact units are described. One pilot plant installed in a single-family house built to MINERGIE standard in Gelterkinden, Switzerland, provided data on a compact unit. These results of measurements made on this and a further installation in a MINERGIE-P ultra-low energy consumption house in Zeiningen, Switzerland, are presented and discussed. Calculation methods, including exergy considerations are reviewed and their validation is discussed.

  8. Modeling and simulation performance of sucker rod beam pump

    Science.gov (United States)

    Aditsania, Annisa; Rahmawati, Silvy Dewi; Sukarno, Pudjo; Soewono, Edy

    2015-09-01

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption proved non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.

  9. Modeling and simulation performance of sucker rod beam pump

    Energy Technology Data Exchange (ETDEWEB)

    Aditsania, Annisa, E-mail: annisaaditsania@gmail.com [Department of Computational Sciences, Institut Teknologi Bandung (Indonesia); Rahmawati, Silvy Dewi, E-mail: silvyarahmawati@gmail.com; Sukarno, Pudjo, E-mail: psukarno@gmail.com [Department of Petroleum Engineering, Institut Teknologi Bandung (Indonesia); Soewono, Edy, E-mail: esoewono@math.itb.ac.id [Department of Mathematics, Institut Teknologi Bandung (Indonesia)

    2015-09-30

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption proved non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.

  10. Flow dynamical behavior and performance of a micro viscous pump with unequal inlet and outlet areas

    Directory of Open Access Journals (Sweden)

    Chenhui Hu

    2016-01-01

    Full Text Available The micro viscous pump is an important type of fluidic device. Optimizing the working performance of the pump is crucial for its wider application. A micro viscous pump design with unequal inlet and outlet areas is proposed in this paper. The flow field of the viscous pump is investigated using 2D laminar simulations. The mass flow rate and driving power are studied with different opening angles. The effects of the Reynolds number and the pressure load on the working performance are discussed in detail. Flow structures and vortex evolution are analyzed. With larger inlet and outlet areas, a higher mass flow rate is obtained and less driving power is achieved. A high pressure load results in a reduction in mass flow rate and an increase in driving power. Pumps with large opening angles are more susceptive to the Reynolds number and the pressure load. The adverse impact of the pressure load can be reduced by increasing the rotor speed. The vortex structure is affected by the geometric and operating parameters in the flow field. The flow dynamical behavior of the viscous pump exerts significant influence on its pumping ability. The present work gives rise to performance improvements for the micro viscous pump.

  11. Sizing and performance features of rotary and reciprocating positive displacement pumps

    Institute of Scientific and Technical Information of China (English)

    Cooper Paul; Wang Chaowei

    2014-01-01

    An overview of some popular rotary and reciprocating positive displacement (PD)pump types is given with the objective of presenting and comparing the respective sizing relationships and performance features.Reciprocating pumps discussed are the piston and plunger types.Rotary pumps addressed are gear (external and internal),vane,lobe,screw,and liquid ring pumps.To put the re-lative pump sizes in perspective,attention is fixed on the rotors or reciprocating elements of PD pumps,just as impellers indicate the sizes of rotodynamic pumps.The size of a PD pump is found from a dimensionless combination of displacement flow rate,rotative speed and diameter.The flow rate, head (or pressure rise)and power are related through the component efficiencies.The cavitation coef-ficient,often close to unity,connects the rotor tip speed or piston speed with the required NPSH, which can also be affected by the pressure rise of the pump due to leakage across the internal clea-rances.Operational effects due to cavitation,ingestion of gas or abrasives,and viscous and non-New-tonian fluids are discussed.

  12. Numerical Characterization of the Performance of Fluid Pumps Based on a Wankel Geometry

    Directory of Open Access Journals (Sweden)

    Stephen Wan

    2014-01-01

    Full Text Available The performance of fluid pumps based on Wankel-type geometry, taking the shape of a double-lobed limaçon, is characterized. To the authors’ knowledge, this is the first time such an attempt has been made. To this end, numerous simulations for three different pump sizes were carried out and the results were understood in terms of the usual scaling coefficients. The results show that such pumps operate as low efficiency (<30% valveless positive displacements pumps, with pump flow-rate noticeably falling at the onset of internal leakage. Also, for such pumps, the mechanical efficiency varies linearly with the head coefficient, and, within the onset of internal leakage, the capacity coefficient holds steady even across pump efficiency. Simulation of the flow field reveals a structure rich in three-dimensional vortices even in the laminar regime, including Taylor-like counterrotating vortex pairs, pointing towards the utility of these pumps in microfluidic applications. Given the planar geometry of such pumps, their applications as microreactors and micromixers are recommended.

  13. JPMT: A Java Performance Monitoring Tool

    NARCIS (Netherlands)

    Harkema, M.; Quartel, Dick; van der Mei, Robert; Gijsen, Bart

    This paper describes our Java Performance Monitoring Toolkit (JPMT), which is developed for detailed analysis of the behavior and performance of Java applications. JPMT represents internal execution behavior of Java applications by event traces, where each event represents the occurrence of some

  14. Hybrid Modeling Improves Health and Performance Monitoring

    Science.gov (United States)

    2007-01-01

    Scientific Monitoring Inc. was awarded a Phase I Small Business Innovation Research (SBIR) project by NASA's Dryden Flight Research Center to create a new, simplified health-monitoring approach for flight vehicles and flight equipment. The project developed a hybrid physical model concept that provided a structured approach to simplifying complex design models for use in health monitoring, allowing the output or performance of the equipment to be compared to what the design models predicted, so that deterioration or impending failure could be detected before there would be an impact on the equipment's operational capability. Based on the original modeling technology, Scientific Monitoring released I-Trend, a commercial health- and performance-monitoring software product named for its intelligent trending, diagnostics, and prognostics capabilities, as part of the company's complete ICEMS (Intelligent Condition-based Equipment Management System) suite of monitoring and advanced alerting software. I-Trend uses the hybrid physical model to better characterize the nature of health or performance alarms that result in "no fault found" false alarms. Additionally, the use of physical principles helps I-Trend identify problems sooner. I-Trend technology is currently in use in several commercial aviation programs, and the U.S. Air Force recently tapped Scientific Monitoring to develop next-generation engine health-management software for monitoring its fleet of jet engines. Scientific Monitoring has continued the original NASA work, this time under a Phase III SBIR contract with a joint NASA-Pratt & Whitney aviation security program on propulsion-controlled aircraft under missile-damaged aircraft conditions.

  15. Performance, requirements and testing in individual monitoring

    DEFF Research Database (Denmark)

    Julius, H.W.; Christensen, P.; Marshall, T.O.

    1990-01-01

    monitoring, and in particular of those related to the energy and angular dependences of the dosemeters. These data are important for the testing of the dosimetry systems. Finally testing programmes in individual monitoring are discussed and four categories of testing are proposed.......For implementation of the ICRP requirements in practical routine monitoring, a specification is needed with respect to specific performance criteria of the dosimetry system. This includes the dosemeters, and procedures for initial and on-going testing of the dosimetry systems to ensure...... that the specified criteria are continuously met. Methods are here specified for establishing performance criteria, and satisfying the ICRP overall accuracy requirements for individual monitoring. Furthermore, procedures are given for obtaining numerical values of the uncertainties connected with individual...

  16. Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power

    Science.gov (United States)

    Polzin, K. A.; Pearson, J. B.; Schoenfeld, M. P.; Webster, K.; Houts, M. G.; Godfroy, T. J.; Bossard, J. A.

    2010-01-01

    Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

  17. WiMAX network performance monitoring & optimization

    DEFF Research Database (Denmark)

    Zhang, Qi; Dam, H

    2008-01-01

    frequency reuse, capacity planning, proper network dimensioning, multi-class data services and so on. Furthermore, as a small operator we also want to reduce the demand for sophisticated technicians and man labour hours. To meet these critical demands, we design a generic integrated network performance......In this paper we present our WiMAX (worldwide interoperability for microwave access) network performance monitoring and optimization solution. As a new and small WiMAX network operator, there are many demanding issues that we have to deal with, such as limited available frequency resource, tight...... this integrated network performance monitoring and optimization system in our WiMAX networks. This integrated monitoring and optimization system has such good flexibility and scalability that individual function component can be used by other operators with special needs and more advanced function components can...

  18. [Monitoring of diabetes compensation in patients treated with an insulin pump in the Czech Republic].

    Science.gov (United States)

    Rušavý, Zdeněk; Honěk, Petr; Dušek, Ladislav; Pavlík, Tomáš; Žďarská, Denisa Janíčková; Kvapil, Milan

    2015-11-01

    Insulin pump treatment (IP) is one of the ways of intensive insulin therapy, designed preferentially for patients with type 1 diabetes. The price of the treatment is higher than that of the conventional basalbolus and insulin regimens using repeated insulin application with a dose selector. Quality assessment of IP therapy monitoring in patients with DM in a representative sample of the patient population with DM kept in the database of the General Health Insurance Company of the Czech Republic (VZP) which provided health care coverage for 63% of Czech population in 2014. We identified all individuals in the VZP database who had a record of DM diagnosis (E10-E16 based on ICD 10) or who had any antidiabetic therapy prescribed (ATC group A10) in the period of 2009-2013. Over the whole period of 2009-2014 there were overall n=4,002 unique patients with DM identified in the VZP data, who were treated with IP within the assessment period. Incidence for the year 2014 (the newly treated with an insulin pump): all patients who had IP recorded in 2014 while in the preceding period of 2009-2013 they had no record of IP use. Prevalence for the year 2014 (all treated with an insulin pump): all the patients who for the period of 2010-2014 had at least once insulin pump use recorded and who did not die before 2014. Quality control parameters (HbA1c examination and consumption of glucose level test strips) for patients treated with IP were only assessed in detail for the year 2014, namely for all patients undergoing insulin pump treatment in 2014 throughout the year (i.e. from 1 January 2014 to 31 December 2014), i.e. in n=3,189 patients in all. In 2014 there were 247 incident patients and 3 794 prevalent patients. IP was newly introduced for almost 50% of the patients aged 20-39 years. In 2014 an average frequency of HbA1c examination equaled 3.38 per patient and 98.5% patients were examined for HbA1c at least once. An average consumption of glucose level testing strips per

  19. Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM

    Energy Technology Data Exchange (ETDEWEB)

    1982-06-30

    The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)

  20. A New Method to Calculate Centrifugal Pump Performance Parameters for Industrial Oils

    Directory of Open Access Journals (Sweden)

    mohammad hassan shojaeefard

    2015-01-01

    Full Text Available Pumping of oil instead of water using centrifugal pumps causes rapid increase in the hydraulic losses which results significant reduction in head and efficiency. Therefore, deriving analytical methods to calculate variation of pump performance parameters versus working fluid viscosity is very important. In the present study, a novel method is proposed to calculate the head (H, efficiency ( and input power ( in P based on the loss analysis for pumps using industrial oils. A computer code is developed based on represented method and the results of this method are compared with experimental results for a centrifugal pump of type KWP KBloc65- 200. The results show good agreement between analytical and experimental methods. Finally, using such computer code, diagrams of head, efficiency and input power versus working fluid viscosity are plotted.The results show an interesting point known as “sudden rising head” which is observed experimentally and numerically in literatures.

  1. Field monitoring and evaluation of a residential gas-engine-driven heat pump: Volume 2, Heating season

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.D.

    1995-11-01

    The Federal Government is the largest single energy consumer in the United States; consumption approaches 1.5 quads/year of energy (1 quad = 10{sup 15} Btu) at a cost valued at nearly $10 billion annually. The US Department of Energy (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US Government. Pacific Northwest Laboratory (PNL) is one of four DOE national multiprogram laboratories that participate in the NTDP by providing technical expertise and equipment to evaluate new, energy-saving technologies being studied and evaluated under that program. This two-volume report describes a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology -- a gas-engine-driven heat pump. The unit was installed at a single residence at Fort Sam Houston, a US Army base in San Antonio, Texas, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were York International, the heat pump manufacturer; Gas Research Institute (GRI), the technology developer; City Public Service of San Antonio, the local utility; American Gas Cooling Center (AGCC); Fort Sam Houston; and PNL.

  2. Field monitoring and evaluation of a residential gas-engine-driven heat pump: Volume 1, Cooling season

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.D.

    1995-09-01

    The Federal government is the largest single energy consumer in the United States; consumption approaches 1.5 quads/year of energy (1 quad = 10{sup 15} Btu) at a cost valued at nearly $10 billion annually. The US Department of Energy (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL)is one of four DOE national multiprogram laboratories that participate in the NTDP by providing technical expertise and equipment to evaluate new, energy-saving technologies being studied and evaluated under that program. This two-volume report describes a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology -- a gas-engine-driven heat pump. The unit was installed at a single residence at Fort Sam Houston, a US Army base in San Antonio, Texas, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were York International, the heat pump manufacturer, Gas Research Institute (GRI), the technology developer; City Public Service of San Antonio, the local utility; American Gas Cooling Center (AGCC); Fort Sam Houston; and PNL.

  3. Performance improvement of air source heat pump by using gas-injected rotary compressor

    Science.gov (United States)

    Wang, B. L.; Liu, X. R.; Ding, Y. C.; Shi, W. X.

    2017-08-01

    Rotary compressor is most widely used in small capacity refrigeration and heat pump systems. For the air source heat pump, the heating capacity and the COP will be obviously degraded when it is utilized in low temperature ambient. Gas injection is an effective method to enhance its performance under those situations, which has been well applied in air source heat pump with scroll compressor. However, the development of the gas injection technology in rotary compressor is relatively slow due to limited performance improvement. In this research, the essential reason constraining the improvement of the gas injection on the rotary compressor and its heat pump system is identified. Two new injection structures for rotary compressors has been put forward to overcome the drawback of traditional injection structures. Based on a verified numerical model, the thermodynamic performance of air source heat pumps with the new gas-injected rotary compressor are investigated. The results indicate that, compared to the air source heat pump with the traditional gas injected rotary compressor, the new injection structures both can enhance heating capacity and COP of the air source heat pump obviously.

  4. Performance of a 10 kilowatt wind-electric water pumping system for irrigating crops

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States); Molla, S. [Texas A& M Univ., College Station, TX (United States)

    1997-12-31

    A 10 kW wind-electric water pumping system was tested for field crop irrigation at pumping depths from 50 to 120 m. The wind turbine for this system used a permanent magnet alternator that powered off-the-shelf submersible motors and pumps without the use of an inverter. Pumping performance was determined at the USDA-Agricultural Research Service (ARS), Wind Energy Laboratory in Bushland, TX for the 10 kW wind turbine using a pressure valve and a pressure tank to simulate different pumping depths. Pumping performance was measured for two 10 kW wind turbines of the same type at farms near the cities of Garden City, TX and Stiles, TX. The pumping performance data collected at these actual wells compared favorably with the data collected at the USDA-ARS, Wind Energy Laboratory. If utility generated electricity was accessible, payback on the wind turbine depended on the cost of utility generated electricity and the transmission line extension cost.

  5. Integrated insulin pump therapy with continuous glucose monitoring for improved adherence: technology update

    Directory of Open Access Journals (Sweden)

    Tumminia A

    2015-09-01

    Full Text Available Andrea Tumminia,1 Laura Sciacca,1 Lucia Frittitta,1 Sebastiano Squatrito,1 Riccardo Vigneri,2 Rosario Le Moli,1 Letizia Tomaselli2 1Endocrinology, Department of Clinical and Experimental Medicine, University of Catania, Garibaldi-Nesima Hospital, Catania, Italy; 2Endocrinology, Garibaldi-Nesima Hospital, Catania, Italy Abstract: Insulin pump therapy combined with real-time continuous glucose monitoring, known as sensor-augmented pump (SAP therapy, has been shown to improve metabolic control and to reduce the rate of hypoglycemia in adults with type 1 diabetes compared to multiple daily injections or standard continuous subcutaneous insulin infusion. Glycemic variability is also reduced in patients on SAP therapy. This approach allows patients to monitor their glucose levels being informed of glycemic concentration and trend. Trained diabetic patients, therefore, can appropriately modify insulin infusion and/or carbohydrate intake in order to prevent hypo- or hyperglycemia. For these reasons, SAP therapy is now considered the gold standard for type 1 diabetes treatment. To be clinically effective, however, devices and techniques using advanced technology should not only have the potential to theoretically ameliorate metabolic control, but also be well accepted by patients in terms of satisfaction and health-related quality of life, because these factors will improve treatment adherence and consequently overall outcome. SAP therapy is generally well tolerated by patients; however, many clinical trials have identified significant noncompliance in the use of this device, most notably in the pediatric and adolescent populations. In this review we aim to analyze the main reasons for good or poor adherence to SAP therapy and to provide useful tips in order to fully benefit from this kind of novel therapeutic approach. Keywords: sensor-augmented insulin pump therapy, type 1 diabetes, quality of life, patient adherence, continuous subcutaneous insulin

  6. Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

    Science.gov (United States)

    Bari, H. M.; Deshpande, A. A.; Jalkote, P. S.; Patil, S. S.

    2012-05-01

    This paper shares a success story out of the implementation of Co-ordinated Condition Monitoring techniques at DTPS, wherein imminent Mis-alignment of HT auxiliary BFP - 1B and Motor bearing failure of ID FAN - 1B was diagnosed. On 30/12/2010, Booster Pump DE horizontal reading increased from 4.8 to 5.1 and then upto 5.9 mm/sec. It was suspected that Booster pump was mis-aligned with Motor. To confirm misalignment, Phase Analysis was also done which showed that Coupling phase difference was 180 Degrees. Vibration & Phase Analysis helped in diagnosing the exact root cause of abnormity in advance, saving plant from huge losses which could have caused total cost of £ 104,071. On 06/01/2011, ID fan 1B Motor NDE & DE horizontal vibration readings deviated from 0.5 to 0.8 and 0.6 to 0.8 mm/sec (RMS) respectively. Noise level increased from 99.1 to 101.9 db. It was suspected that Motor bearings had loosened over the shaft. Meanwhile, after opening of Motor, Inner race of NDE side was found cracked and loosened over the shaft. Vibration Analysis & Noise Monitoring helped in diagnosing the exact root cause of abnormity in advance, saving plant from huge losses which could have caused total cost of £ 308,857.

  7. Performance analysis of air——water dual source heat pump water heater with heat recovery

    Institute of Scientific and Technical Information of China (English)

    CHEN ZeShao; TAO WenQuan; ZHU YanWen; HU Peng

    2012-01-01

    A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.

  8. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

  9. Algorithm to determine electrical submersible pump performance considering temperature changes for viscous crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Valderrama, A. [Petroleos de Venezuela, S.A., Distrito Socialista Tecnologico (Venezuela); Valencia, F. [Petroleos de Venezuela, S.A., Instituto de Tecnologia Venezolana para el Petroleo (Venezuela)

    2011-07-01

    In the heavy oil industry, electrical submersible pumps (ESPs) are used to transfer energy to fluids through stages made up of one impeller and one diffuser. Since liquid temperature increases through the different stages, viscosity might change between the inlet and outlet of the pump, thus affecting performance. The aim of this research was to create an algorithm to determine ESPs' performance curves considering temperature changes through the stages. A computational algorithm was developed and then compared with data collected in a laboratory with a CG2900 ESP. Results confirmed that when the fluid's viscosity is affected by the temperature changes, the stages of multistage pump systems do not have the same performance. Thus the developed algorithm could help production engineers to take viscosity changes into account and optimize the ESP design. This study developed an algorithm to take into account the fluid viscosity changes through pump stages.

  10. The Relationships between Monitoring, Regulation and Performance

    Science.gov (United States)

    Koriat, Asher

    2012-01-01

    The articles in this Special Issue reflect the growing interest in applying laboratory-based research to educational settings. These articles highlight the contribution of metacognitive monitoring and self-regulation to effective learning and performance. At the same time, they illustrate the methodological and theoretical challenges involved in…

  11. ERP Correlates of Performance Monitoring in Elderly

    Science.gov (United States)

    Schreiber, Melanie; Pietschmann, Maria; Kathmann, Norbert; Endrass, Tanja

    2011-01-01

    Previous studies on performance monitoring repeatedly found attenuated error-related negativities (Ne/ERN) in elderly, while findings for the correct-related negativity (Nc/CRN) are inconsistent. The present study aimed at clarifying inconsistent Nc/CRN results in elderly. Therefore, a refined design was employed to control for potential…

  12. Comparison between design and actual energy performance of a HVAC-ground coupled heat pump system in cooling and heating operation

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, S. [Energesis Ingenieria S.L., Ciudad Politecnica de la Innovacion, Camino de Vera s/n, 46022 Valencia (Spain); Montero, A. [Instituto de Ingenieria Energetica, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Urchueguia, J.F. [Instituto Universitario de Matematica Pura y Aplicada, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2010-09-15

    This work compares the experimental results obtained for the energy performance study of a ground coupled heat pump system with the design values predicted by means of standard methodology. The system energy performance of a monitored ground coupled heat pump system is calculated using the instantaneous measurements of temperature, flow and power consumption and these values are compared with the numerical predictions. These predictions are performed with the TRNSYS software tool following standard procedures taking the experimental thermal loads as input values. The main result of this work is that simulation results solely based on nominal heat pump capacities and performances overestimate the measured overall energy performance by a percentage between 15% and 20%. A sensitivity analysis of the simulation results to changes in percentage of its input parameters showed that the heat pump nominal coefficient of performance is the parameter that mostly affects the energy performance predictions. This analysis supports the idea that the discrepancies between experimental results and simulation outputs for this ground coupled system are mainly due to heat pump performance degradation for being used at partial load. An estimation of the impact of this effect in energy performance predictions reduces the discrepancies to values around 5%. (author)

  13. The Effect of Viscosity on Performance of a Low Specific Speed Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Rouhollah Torabi

    2016-01-01

    Full Text Available Centrifugal pump delivery head and flow rate drop effectively during the pumping of viscous fluids. Several methods and correlations have been developed to predict reduction rate in centrifugal pump performance when handling viscous fluids, but their results are not in very good agreement with each other. In this study, a common industrial low specific speed pump, which is extensively used in different applications, is studied. The entire pump, including impeller, volute, pipes, front and rear sidewall gaps, and balance holes, is simulated in Computational Fluid Dynamics and 3D full Navier Stokes equations are solved. CFD results are compared with experimental data such as pump performance curves, static pressure in casing, and disk friction loss. Dimensionless angular velocity and leakage rate are investigated in sidewall gap and efficiency variation due to viscosity is studied. The results demonstrate that the behavior of the fluid in sidewall gap is strictly sensitive to viscosity. Increasing viscosity improves the volumetric efficiency by reducing internal leakage through wear rings and balance holes, causing, however, a significant fall in the disk and overall efficiency. Results lead to some recommendations for designing centrifugal pumps which may be used in transferring viscous fluids.

  14. Building America Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes: Habitat for Humanity -- The Woods, Tacoma, Washington

    Energy Technology Data Exchange (ETDEWEB)

    2016-02-01

    The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes (c) Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP) research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.

  15. Use of non evaporable getter pumps to ensure long term performances of high quantum efficiency photocathodes

    Energy Technology Data Exchange (ETDEWEB)

    Sertore, Daniele, E-mail: daniele.sertore@mi.infn.it; Michelato, Paolo; Monaco, Laura [Istituto Nazionale di Fisica Nucleare Sez. Milano – LASA, Via Fratelli Cervi 201, I-20090 Segrate (Italy); Manini, Paolo; Siviero, Fabrizio [SAES Getters S.p.A., Viale Italia 77, 20020 Lainate (Italy)

    2014-05-15

    High quantum efficiency photocathodes are routinely used as laser triggered emitters in the advanced high brightness electron sources based on radio frequency guns. The sensitivity of “semiconductor” type photocathodes to vacuum levels and gas composition requires special care during preparation and handling. This paper will discuss the results obtained using a novel pumping approach based on coupling a 20 l s{sup −1} sputter ion getter pump with a CapaciTorr® D100 non evaporable getter (NEG) pump. A pressure of 8⋅10{sup −8} Pa was achieved using only a sputter ion pump after a 6 day bake-out. With the addition of a NEG pump, a pressure of 2⋅10{sup −9} Pa was achieved after a 2 day bake-out. These pressure values were maintained without power due to the ability of the NEG to pump gases by chemical reaction. Long term monitoring of cathodes quantum efficiencies was also carried out at different photon wavelengths for more than two years, showing no degradation of the photoemissive film properties.

  16. Performance of an Annular Linear Induction Pump with Applications to Space Nuclear Power Systems

    Science.gov (United States)

    Polzin, Kurt A.; Schoenfeld, Michael; Pearson, J. Boise; Webster, Kenneth; Godfroy, Thomas; Adkins, Harold E., Jr.; Werner, James E.

    2010-01-01

    Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 125 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head less than 1 to 90 kPa (less than 0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.

  17. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  18. Numerical identification of blade exit angle effect on the performance for a multistage centrifugal pump impeller

    Directory of Open Access Journals (Sweden)

    Babayigit Osman

    2015-01-01

    Full Text Available Nowadays, single and multistage centrifugal pumps are widely used in industrial and mining enterprises. One of the most important components of a centrifugal pump is the impeller. The performance characteristics are related to the pump comprising the head and the overall efficiency rely a great deal on the impeller geometry. In this work, effects of blade exit angle change on hydraulic efficiency of a multi stage pump impeller are investigated via Ansys-Fluent computational fluid dynamics software for constant width impeller entrance and exit gates, blade numbers and blade thickness. Firstly, the flow volume of a centrifugal pump impeller is generated and then mesh structure is formed for the full impeller flow volume. Secondly, rotational periodic flow model are adopted in order to examine the effect of periodic flow assumption on the performance predictions. Corresponding to the available experimental data, inlet mass flow rate, outlet static pressure and rotation of impeller are taken as 0.02m3s-1, 450 kPa and 2950 rpm, respectively for the water fluid. No slip boundary condition is exposed to all solid of surface in the flow volume. The continuity and Navier-Stokes equations with the k-ε turbulence model and the standard wall functions are used. During the study, numerical analyses are conducted for the blade exit angle values of 18°, 20°, 25°, 30° and 35°. In consequence of the performed analyses, it is determined that hydraulic efficiency of the pump impeller value is changed between 81.0-84.6%. The most convenient blade exit angle that yields 84.6% hydraulic efficiency at is 18°. The obtained results show that the blade exit angle range has an impact on the centrifugal pump performance describing the pump head and the hydraulic efficiency.

  19. Dynamic Model and Performance of Absorption Heat Pump in Shut-down Process

    Institute of Scientific and Technical Information of China (English)

    WANG Lei; LU Zhen

    2002-01-01

    The dynamic model of LiBr absorption heat pump in shut-down process is established. The simulation results show good agreement with the experiments. The dynamic performance of high-pressure generator, low-pressure generator and heat exchanger are analyzed in detail. The proper shut-down mode of the heat pump is presented,which, in consideration of solution parameters, has a great effect on the possibility of crystallization of some components.

  20. The impact of the weather conditions on the cooling performance of the heat pump driven by an internal natural gas combustion engine

    Directory of Open Access Journals (Sweden)

    Janovcová Martina

    2015-01-01

    Full Text Available Market with sources of heat and cold offers unlimited choice of different power these devices, design technology, efficiency and price categories. New progressive technologies are constantly discovering, about which is still little information, which include heat pumps powered by a combustion engine running on natural gas. A few pieces of these installations are in Slovakia, but no studies about their work and effectiveness under real conditions. This article deals with experimental measurements of gas heat pump efficiency in cooling mode. Since the gas heat pump works only in system air – water, air is the primary low – energy source, it is necessary to monitor the impact of the climate conditions for the gas heat pump performance.

  1. Analysis of the performances of an axial flow tandem pump based on CFD computations

    Science.gov (United States)

    Zhao, Y.; Bai, Z. Y.; Zhang, M. D.; Wang, G. Y.

    2012-11-01

    Tandem pump, compared with multistage pump, goes without guide vanes between impellers. Significant reduction of the axial geometry scale, resulting from lack of guide vanes, makes great sense to high-speed propulsion. Direct interactions between front and rear impellers may lead to special flows, which are different from those in a multistage pump. There are few studies of these differences. In this article, CFD computations of flows in an axial flow tandem pump are conducted to predict the performances. FBM turbulence model, which is introduced to commercial software, is used for the simulations. Circulation coefficient is defined to help analyze energy characteristics. The results demonstrate that power of the tandem pump increases slowly as discharge is getting larger. The tandem pump has better adaptability under large discharge conditions. The head of the rear impeller is not sensitive to discharge's change, which results from that the front impeller weakens the influence of discharge's change on the rear impeller, so pump's energy characteristics may be improved.

  2. Performance studies of Cryocooler based cryosorption pumps with indigenous activated carbons for fusion applications

    Science.gov (United States)

    Kasthurirengan, S.; Vivek, G. A.; Verma, Ravi; Behera, Upendra; Udgata, Swarup; Gangradey, Ranjana

    2017-02-01

    Cryosorption pumps are the only solution for pumping helium and hydrogen in fusion systems, due to their high pumping speeds and suitability in harsh environments. Their development requires the right Activated Carbons (ACs) and suitable adhesives to bind them to metallic panels with liquid helium (LHe) flow channels. However, their performance evaluation will require large quantities of LHe. Alternatively, these pumps can be built with small size panels adhered with ACs and cooled by a cryocooler. The paper describes the development of a cryopump using a commercial cryocooler (Sumitomo RDK415D), with 1.5W@4.2 K, integrated with small size AC panel mounted on 2nd stage, with the 1st stage acting as radiation shield. Under no load, the cryopump reaches the ultimate pressure of 2.1E-7 mbar. The pump is built using panels with different indigenously developed ACs such as granules, pellets, ACF-FK2 and activated carbon of knitted IPR cloth. We present the experimental results of pumping speeds for gases such as nitrogen, argon and helium using the procedures outlined by American Vacuum Society (AVS). These studies will enable to arrive at the right ACs and adhesives for the development of large scale cryosorption pumps with liquid helium flow.

  3. Performance comparison of bismuth/erbium co-doped optical fibre by 830 nm and 980 nm pumping

    Science.gov (United States)

    Yan, Binbin; Luo, Yanhua; Zareanborji, Amirhassan; Xiao, Gui; Peng, Gang-Ding; Wen, Jianxiang

    2016-10-01

    The performance of bismuth/erbium co-doped fibre (BEDF) by 830 nm and 980 nm pumping has been studied in detail, including the small signal absorption, pump absorption, emission, gain and excited state absorption (ESA). Based on the study, energy transition diagrams of BEDF under 830 nm or 980 nm pumping are proposed to clarify the spectroscopic properties. The results demonstrate the advantages of 830 nm pumping for BEDF over 980 nm pumping when considering the absorption, pumping efficiency, excited state absorption and optical amplification.

  4. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    Science.gov (United States)

    Januševičius, Karolis; Streckienė, Giedrė

    2013-12-01

    In near zero energy buildings (NZEB) built in Baltic countries, heat production systems meet the challenge of large share domestic hot water demand and high required heating capacity. Due to passive solar design, cooling demand in residential buildings also needs an assessment and solution. Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country. The presented paper describes a simulation study of solar assisted heat pump systems carried out in TRNSYS. The purpose of this simulation was to investigate how the performance of a solar assisted heat pump combination varies in near zero energy building. Results of three systems were compared to autonomous (independent) systems simulated performance. Different solar assisted heat pump design solutions with serial and parallel solar thermal collector connections to the heat pump loop were modelled and a passive cooling possibility was assessed. Simulations were performed for three Baltic countries: Lithuania, Latvia and Estonia.

  5. Hardware and software system for monitoring oil pump operation in power high-voltage transformers

    Directory of Open Access Journals (Sweden)

    Михайло Дмитрович Дяченко

    2017-07-01

    Full Text Available The article considers the basic prerequisites for the creation of an automated monitoring system for oil pumps of high-voltage transformers. This is due to the fact that the long operation of oil pumps results in deterioration and destruction of bearings, rubbing of the rotor, breakage and damage to the impeller, leakage, etc., which inevitably causes a significant decrease in the insulating properties of the transformer oil and leads to expenditures for its further recovery. False triggerings of gas protection sometimes occur. Continuous operation of the electric motor also requires additional equipment to protect the motor itself from various emergency situations, such as a short in the stator winding, a housing breakdown, an incomplete phase mode, etc. The use of stationary systems provides: diagnosing defects at an early stage of their development, increasing the reliability and longevity of the equipment components, increasing the overhaul period, decreasing the number of emergency stops, and adjusting the schedule of preventative maintenance. The basic principles of identification of the damaged part of the oil pump are given, the hardware and algorithmic solutions are considered in the work. The full-scale tests of the model sample on the power transformer of the high-voltage substation confirmed the assumption of the possibility of detecting the damaged unit separating it from the rest connected in one mechanical structure. A detailed analysis of the operation of each of the units is carried out by means of the general substation switchboard and displayed as graphs, diagrams and text messages. When the limit values of vibration are reached, faults in the operation of the unit are detected, the overlimit current values, a warning alarm is activated, and the command to disconnect the damaged unit is issued. The optimal solution for the organization of the information collection system using the principle of sensor networks, but combined

  6. Solar-assisted heat pumps: impact of evaporator characteristics on performance

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1982-03-01

    Five water-refrigerant heat exchangers were tested as part of a program of experimental studies of solar-assisted heat pump (SAHP) components and controls. The aim of this work is to establish ways of improving on the benchmark designs of two prototype SAHPs, one each built by Northrup Incorporated and Lennox Industries Incorporated under contract to the US Department of Energy (DOE). The performance of a water source heat pump, employing any of these evaporators, can be projected using these data, in conjunction with appropriate data pertaining to the rest of the heat pump. Thus, the impact of the evaporator's characteristics on the heat pump performance as a whole may be assessed. The necessary supplementary data may be obtained from compressor curves and condenser performance data, or from test data from a heat pump for which substitution of one of the evaporators considered in this report is contemplated. The steady state performance of the Northrup prototype SAHP employing each of the heat exchangers tested is projected using these test data. The projections of coefficient of performance (COP) versus entering water temperature performance are presented along with the original test data for comparison.

  7. Field Performance of Inverter-Driven Heat Pumps in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, James [Consortium of Advanced Residential Buildings, Norwalk, CT (United States); Aldrich, Robb [Consortium of Advanced Residential Buildings, Norwalk, CT (United States)

    2015-08-19

    Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heating performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.

  8. Numerical investigation of the effect of number of blades on centrifugal pump performance

    Science.gov (United States)

    Kocaaslan, O.; Ozgoren, M.; Babayigit, O.; Aksoy, M. H.

    2017-07-01

    In this study, the flow structure in a centrifugal pump was numerically investigated for the different blade numbers in the impeller between 5 and 9. The pump used in the study is a single-stage horizontal shafted centrifugal pump. The original pump impeller was designed as 7 blades for the parameters of flow rate Q=100 mł/h, head Hm=180 kPa and revolution n=1480 rpm. First, models of impellers with the different blade numbers between 5 and 9 and the volute section of the centrifugal pump were separately drawn using Solidworks software. Later, grid structures were generated on the flow volume of the pump. Last, the flow analyses were performed and the flow characteristics under different operational conditions were determined numerically. In the numerical analyses, k-ɛ turbulence model and standard wall functions were used to solve turbulent flow. Balance holes and surface roughness, which adversely affect the hydraulic efficiency of pumps, were also considered. The obtained results of the analyses show that the hydraulic torque and head values have increased with the application of higher number of the impeller blades. For the impellers with 5 and 9 blades on the design flow rate of 100 mł/h (Q/Qd=1), the hydraulic torque and head were found 49/59.1 Nm and 153.1/184.4 kPa, respectively. Subsequently the hydraulic efficiencies of each pump were calculated. As a result, the highest hydraulic efficiency on the design flow rate was calculated as 54.16% for the pump impeller having 8 blades.

  9. Monitoring SLAC High Performance UNIX Computing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lettsome, Annette K.; /Bethune-Cookman Coll. /SLAC

    2005-12-15

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface.

  10. Induced modifications on algae photosynthetic activity monitored by pump-and-probe technique

    Energy Technology Data Exchange (ETDEWEB)

    Barbini, R.; Colao, F.; Fantoni, R.; Palucci, A.; Ribezzo, S. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Tarzillo, G.; Carlozzi, P.; Pelosi, E. [CNR, Florence (Italy). Centro Studi Microorganismi Autotrofi

    1995-12-01

    The lidar fluorosensor system available at ENEA Frascati has been used for a series of laboratory measurements on brackish-water and marine phytoplankton grown in laboratory with the proper saline solution. The system, already used to measure the laser induced fluorescence spectra of different algae species and their detection limits, has been upgraded with a short pulse Nd:YAG laser and rearranged to test a new technique based on laser pump and probe excitation. Results of this new technique for remote monitoring of the in-vivo photosynthetic activity will be presented, as measured during a field campaign carried out in Florence during the Autumn 1993, where the effects of an actinic saturating light and different chemicals have also been checked.

  11. Constructing a model-based software monitor for the insulin pump behavior.

    Science.gov (United States)

    Babamir, Seyed Morteza

    2012-04-01

    Modern medical systems undertaking the task of surveillance of patients are safety-critical systems steered by software. Such systems will bring man's life into hazard if they fail to meet patients' requirements; so, adequate reliability of the algorithms and computations used by software of such systems is a matter of concern. The environment of a medical safety-critical system consisting of a patient has safety requirements that should be satisfied by the system. A safety requirement is the one that if it is violated, the system environment will be subject to severe risk. An effective method to verify the algorithms and computations used by software of such systems against safety requirements is to keep the software under surveillance at run-time. This paper aims to present a model-based method to construct a run-time monitor for a safety-critical medical system called Continuous Infusion Insulin Pump (CIIP).

  12. Coefficient of Performance Optimization of Single-Effect Lithium-Bromide Absorption Cycle Heat Pumps

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    In this paper, we investigate the coefficient of performance (COP) of a LiBr absorption cycle heat pump under different operating conditions. The investigation is carried out using a dynamical model fitted against data recorded from an actual heat pump used for district heating in S......⊘nderborg, Denmark. Since the model is too complex to study analytically, we vary different input variables within the permissible operating range of the heat pump and evaluate COP at the resulting steady-state operating points. It is found that the best set-point for each individual input is located at an extreme......-state operation of the heat pump, while avoiding crystallization issues....

  13. Numerical investigation of degas performance on impeller of medium-consistency pump

    Directory of Open Access Journals (Sweden)

    Hong Li

    2015-12-01

    Full Text Available Medium-consistency technology is known as the process with high efficiency and low pollution. The gas distribution was simulated in the medium-consistency pump with different degas hole positions. Rheological behaviors of pulp suspension were obtained by experimental test. A modified Herschel–Bulkley model and the Eulerian gas–liquid two-phase flow model were utilized to approximately represent the behaviors of the medium-consistency pulp suspension. The results show that when the relative position is 0.53, the gas volume ratio is less than 0.1% at the pump outlet and 9.8% at the vacuum inlet, and the pump head is at the maximum. Because of the different numbers of the impeller blades and turbulence blades and the asymmetric volute structure, the gas is distributed unevenly in the impeller. In addition, the pump performance was tested in experiment and the results are used to validate computational fluid dynamics outcomes.

  14. Performance analysis on solid-liquid mixed flow in a centrifugal pump

    Science.gov (United States)

    Ning, C.; Wang, Y.

    2016-05-01

    In order to study the solid-liquid mixed flow hydraulic characteristics of centrifugal pump, the Pro/E software was used for three-dimensional modeling of centrifugal pump chamber. By using the computational fluid dynamics software CFX, the numerical simulation calculation of solid-liquid two-phase flow within whole flow passage of centrifugal pump was conducted. Aim at different particle diameters, the Reynolds-averaged N-S equations with the RNG k-Ɛ turbulence model and SIMPLEC algorithm were used to simulate the two-phase flow respectively on the condition of different volume fraction. The influence of internal flow characteristic on pump performance was analyzed. On the conditions of different particle diameter and different volume fraction, the turbulence kinetic energy and particle concentration are analyzed. It can be found that the erosion velocity ratio on the flow channel wall increases along with the increasing of the volume fraction

  15. Design of a high performance CMOS charge pump for phase-lockedloop synthesizers*

    Institute of Scientific and Technical Information of China (English)

    Li Zhiqun; Zheng Shuangshuang; Hou Ningbing

    2011-01-01

    A new high performance charge pump circuit is designed and realized in 0.18μm CMOS process.A wide input ranged rail-to-rail operational amplifier and self-biasing cascode current mirror are used to enablethe charge pump current to be well matched in a wide output voltage range.Furthermore,a method of adding aprecharging current source is proposed to increase the initial charge current,which will speed up the settling time of CPPLLs.Test results show that the current mismatching can be less than 0.4% in the output voltage range of 0.4 to 1.7 V,with a charge pump current of 100 μA and a precharging current of 70 μA.The average power consumption of the charge pump in the locked condition is around 0.9 mW under a 1.8 V supply voltage.

  16. Performance optimization of total momentum filtering double-resonance energy selective electron heat pump

    Science.gov (United States)

    Ding, Ze-Min; Chen, Lin-Gen; Ge, Yan-Lin; Sun, Feng-Rui

    2016-04-01

    A theoretical model for energy selective electron (ESE) heat pumps operating with two-dimensional electron reservoirs is established in this study. In this model, a double-resonance energy filter operating with a total momentum filtering mechanism is considered for the transmission of electrons. The optimal thermodynamic performance of the ESE heat pump devices is also investigated. Numerical calculations show that the heating load of the device with two resonances is larger, whereas the coefficient of performance (COP) is lower than the ESE heat pump when considering a single-resonance filter. The performance characteristics of the ESE heat pumps in the total momentum filtering condition are generally superior to those with a conventional filtering mechanism. In particular, the performance characteristics of the ESE heat pumps considering a conventional filtering mechanism are vastly different from those of a device with total momentum filtering, which is induced by extra electron momentum in addition to the horizontal direction. Parameters such as resonance width and energy spacing are found to be associated with the performance of the electron system.

  17. Heating performance of a ground source heat pump system installed in a school building

    Institute of Scientific and Technical Information of China (English)

    Jaedo; SONG; Kwangho; LEE; Youngman; JEONG; Seongir; CHEONG; Jaekeun; LEE; Yujin; HWANG; Yeongho; LEE; Donghyuk; LEE

    2010-01-01

    The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.

  18. Performance study of a heat pump dryer system for speciality crops - Pt. 1: development of a simulation model

    Energy Technology Data Exchange (ETDEWEB)

    Adapa, P.K.; Schoenau, G.J.; Sokhansanj, S. [University of Saskatchewan (Canada). College of Engineering

    2002-07-01

    This research is concerned with the technology of heat pump assisted drying of specialty crops. A simplified procedure for modelling the performance of a low temperature heat pump dryer was developed. The system modelled consists of a vapour compression heat pump coupled to a continuous cross flow bed dryer. The model takes into account the detailed heat and mass transfer phenomena taking place in the heat pump and dryer circuits. (author)

  19. NUMERICAL INVESTIGATION OF PERFORMANCE OF AN AXIAL-FLOW PUMP WITH INDUCER

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The interaction of flow through the inducer and impeller of an axial-flow pump equipped with an inducer has significant effect on its performance. This article presents a recent numerical investigation on this topic. The studied pump has an inducer with 3 blades mounted on a conical hub and a 6-blade impeller. The blade angle of the impeller is adjustable to generate different relative circumferential angles between the inducer blade trailing edge and the impeller blade leading edge. A computational fluid dynamics code was used to investigate the flow characteristics and performance of the axial-flow pump. For turbulence closure, the RNG k-ε model was applied with an unstructured grid system. The rotor-stator interaction was treated with a Multiple Reference Frame (MRF) strategy. Computations were performed in different cases: 7 different relative circumferential angles (△θ) between the inducer blade trailing edge and the impeller blade leading edge, and 3 different axial gaps (G) between the inducer and the impeller. The variation of the hydraulic loss in the rotator was obtained by changing △θ. The numerical results show that the pressure generated is minimum in the case of (G=%3D), which indicates that the interference between inducer and impeller is strong if the axial gap is small. The pump performances were predicted and compared to the experimental measurements. Recommendations for future modifications and improvements to the pump design were also given.

  20. Fringe tracking performance monitoring: FINITO at VLTI

    CERN Document Server

    Merand, A; Berger, J -P; Percheron, I; Poupar, S

    2012-01-01

    Since April 2011, realtime fringe tracking data are recorded simultaneously with data from the VLTI/AMBER interferometric beam combiner. Not only this offers possibilities to post-process AMBER reduced data to obtain more accurate interferometric quantities, it also allows to estimate the performance of the fringe tracking a function of the conditions of seeing, coherence time, flux, etc. First we propose to define fringe tracking performance metrics in the AMBER context, in particular as a function of AMBER's integration time. The main idea is to determine the optimal exposure time for AMBER: short exposures are dominated by readout noise and fringes in long exposures are completely smeared out. Then we present this performance metrics correlated with Paranal local ASM (Ambient Site Monitor) measurements, such as seeing, coherence time or wind speed for example. Finally, we also present some preliminary results of attempts to model and predict fringe tracking performances, using Artificial Neural Networks.

  1. Database Performance Monitoring for the Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    The Database Performance Monitoring (DPM) software (copyright in processes) is being developed at Sandia National Laboratories to perform quality control analysis on time series data. The software loads time indexed databases (currently csv format), performs a series of quality control tests defined by the user, and creates reports which include summary statistics, tables, and graphics. DPM can be setup to run on an automated schedule defined by the user. For example, the software can be run once per day to analyze data collected on the previous day. HTML formatted reports can be sent via email or hosted on a website. To compare performance of several databases, summary statistics and graphics can be gathered in a dashboard view which links to detailed reporting information for each database. The software can be customized for specific applications.

  2. DYNAMIC MATHEMATICAL MODELING AND APPLICATION FOR PUMPING SYSTEM PERFORMANCE INTEGRATED EVALUATION

    Institute of Scientific and Technical Information of China (English)

    Chen Hongxun; Wang Jian; Wu Yuejun

    2003-01-01

    A mathematical model is set to evaluate the overall centrifugal pumping system using asynchronous motor as power. This method can be used to affirm system performance according the transform and the aberrance of interior parameters and exterior performance curves so as to give a reference to the equipment amelioration. The analysis of emulation experiment data suggests the model is effectively used.

  3. Influence of Prewhirl Regulation by Inlet Guide Vanes on Cavitation Performance of a Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Lei Tan

    2014-02-01

    Full Text Available The influence of prewhirl regulation by inlet guide vanes (IGVs on a centrifugal pump performance is investigated experimentally and numerically. The experimental results show that IGVs can obviously change the head and increase the efficiency of the tested centrifugal pump over a wide range of flow rates. Although the cavitation performance is degraded, the variation of the cavitation critical point is less than 0.5 m. Movement of the computed three-dimensional streamlines in suction pipe and impeller are analyzed in order to reveal the mechanism how the IGVs realize the prewhirl regulation. The calculated results show that the influence of IGVs on the cavitation performance of centrifugal pump is limited by a maximum total pressure drop of 1777 Pa, about 7.6% of the total pressure at the suction pipe inlet for a prewhirl angle of 24°.

  4. Digital Image Correlation for Performance Monitoring.

    Energy Technology Data Exchange (ETDEWEB)

    Palaviccini, Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Turner, Daniel Z. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herzberg, Michael [National Security Campus, Kansas City, MO (United States)

    2016-02-01

    Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of nondestructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video (HSV) and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

  5. Test results for the Oasis 3C high performance water-pumping windmill

    Energy Technology Data Exchange (ETDEWEB)

    Eggleston, D.M. [DME Engineering, Midland, TX (United States)

    1997-12-31

    The WINDTech International, L.L.C. Oasis 3C, a 3 m diameter, high-performance water-pumping windmill, was tested at the DME Engineering Wind Test Site just south of Midland, Texas from August through December, 1996. This machine utilizes a 3:1 gearbox with rotating counterweights, similar to a conventional oilfield pumping unit, driven by a multibladed rotor. The rotating counterweight system balances most of the pumping loads and reduces gear loads and starting torque by a factor of at least two and often by a factor of four or more. The torque reduction substantially extends gear and bearing life, and reduces wind speeds required for starting by 30 to 50% or more. The O3C was tested pumping from a quiescent fluid depth of 12.2 m (40 ft) from a 28.3 m (93 ft)-deep well, with additional pumping depth simulated using a pressure regulator valve system. A 9.53 cm (3.75 in.) diameter Harbison-Fischer seal-less single-acting piston pump was used to eliminate pump seal friction as a variable, and standard O3C stroke lengths of 30.5 and 15.2 cm (12 and 6 inches) were used. The regulator spring was set to give a maximum stroke rate of 33 strokes per minute. The water pumped was returned to the well after flowing through a settling tank. The tests were performed in accordance with AWEA WECS testing standards. Instrumentation provided 16 channels of data to accurately measure machine performance, including starting wind speeds, flow rates, O3C azimuth, tail furl angle, wind direction tracking errors, RPM, sucker rod loads, and other variables. The most significant performance data is summarized herein. A mathematical model of machine performance was developed that fairly accurately predicts performance for each of three test conditions. The results verify that the O3C is capable of pumping water at wind speeds from 30% to more than 50% lower than comparable un-counterbalanced units.

  6. Who can monitor the court interpreter's performance?

    DEFF Research Database (Denmark)

    Martinsen, Bodil

    2009-01-01

    and the conflict about her competence was negotiated. Because of this unusual constellation, combined with a multi-method approach, this single case study can shed some light on the question of the participants' ability to monitor the interpreter's performance. Legal professional users of interpreters tend...... to assume that they are able to monitor and thus evaluate the interpreting if the foreign language used in court belongs to the major ones within the Danish educational system, like English or French, contrary to "exotic" migrant languages. This paper highlights the problem that the interpreted proceedings...... are far less transparent for the legal participants than they normally assume. This problem, in turn, stresses the importance of a) the interpreter's competence and self-awareness and b) the use of check interpreters.  ...

  7. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  8. Maintaining Optimum Pump Performance with Specially- Formulated Hydraulic Fluids

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    This paper describes a battery of tests, and related results, that were performed under normal and severe conditions designed to demonstrate that hydraulic fluids formulated with Lubrizol' s high quality anti - wear hydraulic fluid technology can stand up to today's increasing demands for longer life and provide excellent performance under higher operating temperatures and pressures.

  9. Investigation of the Flow Field and Performances of a Centrifugal Pump at Part Load

    Science.gov (United States)

    Prunières, R.; Inoue, Y.; Nagahara, T.

    2016-11-01

    Centrifugal pump performance curve instability, characterized by a local dent at part load, can be the consequence of flow instabilities in rotating or stationary parts. Such flow instabilities often result in abnormal operating conditions which can damage both the pump and the system. In order for the pump to have reliable operation over a wide flow rate range, it is necessary to achieve a design free of instability. The present paper focuses on performance curve instability of a centrifugal pump of mid specific speed (ωs = 0.65) for which instability was observed at part load during tests. The geometry used for this research consist of the first stage of a multi-stage centrifugal pump and is composed of a suction bend, a closed-type impeller, a vaned diffuser and return guide vanes. In order to analyse the instability phenomenon, PIV and CFD analysis were performed. Both methods qualitatively agree relatively well. It appears that the main difference before and after head drop is an increase of reverse flow rate at the diffuser passage inlet on the hub side. This reverse flow decreases the flow passing area at the diffuser passage inlet, disallowing effective flow deceleration and impairing static pressure recovery.

  10. Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

    Directory of Open Access Journals (Sweden)

    Yu Jin Nam

    2015-11-01

    Full Text Available A ground source heat pump system (GSHPS utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated with solar thermal storage was developed. This solar-assisted ground heat pump system (SAGHPS can both maintain the balance of the soil temperature effectively and achieve higher system performance than the conventional system. In this paper, in order to examine the characteristics of the system, a dynamic simulation was conducted under various conditions. The results of our case study provide specific operation data such as heat exchange rate, heat source temperature, and heat pump COP. As a result, the heat pump COP of SAGHPS was 4.7%, 9.3% higher than that of the GSHPS.

  11. Performance analysis of solar-assisted chemical heat-pump dryer

    Energy Technology Data Exchange (ETDEWEB)

    Fadhel, M.I. [Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450, Melaka (Malaysia); Sopian, K.; Daud, W.R.W. [Solar Energy Research Institute, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2010-11-15

    A solar-assisted chemical heat-pump dryer has been designed, fabricated and tested. The performance of the system has been studied under the meteorological conditions of Malaysia. The system consists of four main components: solar collector (evacuated tubes type), storage tank, solid-gas chemical heat pump unit and dryer chamber. A solid-gas chemical heat pump unit consists of reactor, condenser and evaporator. The reaction used in this study (CaCl2-NH{sub 3}). A simulation has been developed, and the predicted results are compared with those obtained from experiments. The maximum efficiency for evacuated tubes solar collector of 80% has been predicted against the maximum experiment of 74%. The maximum values of solar fraction from the simulation and experiment are 0.795 and 0.713, respectively, whereas the coefficient of performance of chemical heat pump (COP{sup h}) maximum values 2.2 and 2 are obtained from simulation and experiments, respectively. The results show that any reduction of energy at condenser as a result of the decrease in solar radiation will decrease the coefficient of performance of chemical heat pump as well as decrease the efficiency of drying. (author)

  12. Performance Test and Flow Measurement of Contra-Rotating Axial Flow Pump

    Institute of Scientific and Technical Information of China (English)

    Akinori Furukawa; Toru Shigemitsu; Satoshi Watanabe

    2007-01-01

    An application of contra-rotating rotors has been proposed against a demand for developing higher specific speed axial flow pump. In the present paper, the advantage and disadvantage of using contra-rotating rotors are described in comparison with conventional type of rotor-stator, based on theoretical and experimental investigations. The advantages are as follows: (1) The pump is inherently designed as smaller sized and at lower rotational speed. (2) A stable head-characteristic curve for flow rate with negative slope appears. (3)As the rear rotor rotational speed is varied as independent control of front rotor, the wider range of high performance operation is obtained by rear rotor speed control in addition to front rotor speed control. The disadvantages are as follows: (1) The structure of double shaft system becomes complex. (2) The pump performance is inferior at over flow rate as the rear rotor loading is weakened. (3) The blade rows interaction from rear rotor to front rotor more strongly appears. Then the rear rotor design is a key to achieve higher pump performance. Some methods to overcome these disadvantages will be discussed in more details toward wider usage of contra-rotating axial flow pump in various industrial fields.

  13. Cavitation performance and flow characteristic in a centrifugal pump with inlet guide vanes

    Science.gov (United States)

    Tan, L.; Zha, L.; Cao, S. L.; Wang, Y. C.; Gui, S. B.

    2015-01-01

    The influence of prewhirl regulation by inlet guide vanes (IGVs) on cavitation performance and flow characteristic in a centrifugal pump is investigated. At the impeller inlet, the streamlines are regulated by the IGVs, and the axial velocity distribution is also influenced by the IGVs. Due to the total pressure loss on the IGVs, the cavitation performance of the centrifugal pump degrades. The cavitation area in impeller with IGVs is larger than one without IGVs. The specify values of total pressure loss between the suction pipe inlet and impeller inlet for three cavitation conditions show that the IGVs will generate additional pressure loss, which is related to the IGVs angles and cavitation conditions.

  14. Performance Monitoring Techniques Supporting Cognitive Optical Networking

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Borkowski, Robert; Zibar, Darko

    2013-01-01

    to solve this issue by realizing a network that can observe, act, learn and optimize its performance, taking into account end-to-end goals. In this letter we present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive...... Heterogeneous Reconfigurable Optical Network. We focus on the approaches developed in the project for optical performance monitoring, which enable the feedback from the physical layer to the cognitive decision system by providing accurate description of the performance of the established lightpaths.......High degree of heterogeneity of future optical networks, such as services with different quality-of-transmission requirements, modulation formats and switching techniques, will pose a challenge for the control and optimization of different parameters. Incorporation of cognitive techniques can help...

  15. Performance of solar photovoltaic array fed water pumping system ...

    African Journals Online (AJOL)

    DR OKE

    This paper discusses the design and performance analysis of a solar ... utilizing a special class of highly rugged machine with simple drive system called ..... Introduction to Fluid Power, Science &Technology, Delmar Cengage Learning.

  16. Experimental analysis on performance of high temperature heat pump and desiccant wheel system

    DEFF Research Database (Denmark)

    Sheng, Ying; Zhang, Yufeng; Deng, Na

    2013-01-01

    In order to solve the problem of high energy consumption for regeneration of desiccant wheel in the rotary desiccant system, high temperature heat pump and desiccant wheel (HTHP&DW) system and corresponding air conditioning unit is built and tested in the extensive thermal hygrometric environment....... When the mixture refrigerant BY-3 is involved in the air source heat pump, the supply air temperatures are in the range as expected except that when in the extreme hot environment (above 36°C), dehumidification capability are satisfied and the regeneration temperatures can satisfy the regeneration...... requirement of desiccant without additional heat. It is also found that outdoor air temperature, humidity ratio and regeneration air flow rate have great impact on the performance of heat pump based on the coefficient of performance (COP) evaluated. COP is not quite high, as the maximum value is 2.26 for heat...

  17. Experimental performance evaluation of heat pump-based steam supply system

    Science.gov (United States)

    Kaida, T.; Sakuraba, I.; Hashimoto, K.; Hasegawa, H.

    2015-08-01

    Heat pumps have become increasingly important as a technology to reduce primary energy consumption and greenhouse effect gas emission. They are presently used mainly on residential air-conditioning and domestic hot water and are expected to spread to industrial heating processes. In 2011, Kobe Steel, Ltd. developed and commercialized two heat pump- based steam supply systems; the high efficiency steam supply system with a steam temperature of 120°C (SGH120) and the system which enables a steam temperature of 165°C (sGh165). For promoting the spread of these industrial heat pumps and enhancing the reliability of them, we investigate experimentally steam generation rate, energy efficiency and controlled performance of the SGH165 under various operating conditions on the assumption of actual different industrial processes, and evaluate technical possibilities for better performance.

  18. Use Alkalinity Monitoring to Optimize Bioreactor Performance.

    Science.gov (United States)

    Jones, Christopher S; Kult, Keegan J

    2016-05-01

    In recent years, the agricultural community has reduced flow of nitrogen from farmed landscapes to stream networks through the use of woodchip denitrification bioreactors. Although deployment of this practice is becoming more common to treat high-nitrate water from agricultural drainage pipes, information about bioreactor management strategies is sparse. This study focuses on the use of water monitoring, and especially the use of alkalinity monitoring, in five Iowa woodchip bioreactors to provide insights into and to help manage bioreactor chemistry in ways that will produce desirable outcomes. Results reported here for the five bioreactors show average annual nitrate load reductions between 50 and 80%, which is acceptable according to established practice standards. Alkalinity data, however, imply that nitrous oxide formation may have regularly occurred in at least three of the bioreactors that are considered to be closed systems. Nitrous oxide measurements of influent and effluent water provide evidence that alkalinity may be an important indicator of bioreactor performance. Bioreactor chemistry can be managed by manipulation of water throughput in ways that produce adequate nitrate removal while preventing undesirable side effects. We conclude that (i) water should be retained for longer periods of time in bioreactors where nitrous oxide formation is indicated, (ii) measuring only nitrate and sulfate concentrations is insufficient for proper bioreactor operation, and (iii) alkalinity monitoring should be implemented into protocols for bioreactor management.

  19. Continuous multichannel monitoring of cave air carbon dioxide using a pumped non-dispersive infrared analyser

    Science.gov (United States)

    Mattey, D.

    2012-04-01

    The concentration of CO2 in cave air is one of the main controls on the rate of degassing of dripwater and on the kinetics of calcite precipitation forming speleothem deposits. Measurements of cave air CO2reveal great complexity in the spatial distribution among interconnected cave chambers and temporal changes on synoptic to seasonal time scales. The rock of Gibraltar hosts a large number of caves distributed over a 300 meter range in altitude and monthly sampling and analysis of air and water combined with continuous logging of temperature, humidity and drip discharge rates since 2004 reveals the importance of density-driven seasonal ventilation which drives large-scale advection of CO2-rich air though the cave systems. Since 2008 we have deployed automatic CO2 monitoring systems that regularly sample cave air from up to 8 locations distributed laterally and vertically in St Michaels Cave located near the top of the rock at 275m asl and Ragged Staff Cave located in the heart of the rock near sea level. The logging system is controlled by a Campbell Scientific CR1000 programmable datalogger which controls an 8 port manifold connected to sampling lines leading to different parts of the cave over a distance of up to 250 meters. The manifold is pumped at a rate of 5l per minute drawing air through 6mm or 8mm id polythene tubing via a 1m Nafion loop to reduce humidity to local ambient conditions. The outlet of the primary pump leads to an open split which is sampled by a second low flow pump which delivers air at 100ml/minute to a Licor 820 CO2 analyser. The software selects the port to be sampled, flushes the line for 2 minutes and CO2 analysed as a set of 5 measurements averaged over 10 second intervals. The system then switches to the next port and when complete shuts down to conserve power after using 20 watts over a 30 minute period of analysis. In the absence of local mains power (eg from the show cave lighting system) two 12v car batteries will power the system

  20. Effects of the number of inducer blades on the anti-cavitation characteristics and external performance of a centrifugal pump

    Energy Technology Data Exchange (ETDEWEB)

    Guo, XiaoMei; Shi, GaoPing [Zhejiang University of Water Resources and Electric Power, Hangzhou (China); Zhu, ZuChao; Cui, BaoLing [Zhejiang Sci-Tech University, Hangzhou (China)

    2016-07-15

    Installing an inducer upstream of the main impeller is an effective approach for improving the anti-cavitation performance of a high speed centrifugal pump. For a high-speed centrifugal pump with an inducer, the number of inducer blades can affect its internal flow and external performance. We studied the manner in which the number of inducer blades can affect the anti-cavitation characteristics and external performance of a centrifugal pump. We first use the Rayleigh-Plesset equation and the mixture model to simulate the vapor liquid flow in a centrifugal pump with an inducer, and then predict its external performance. Finally, we tested the external performance of a centrifugal pump with 2-, 3- and 4-bladed inducers, respectively. The results show that the simulations of external performance in a centrifugal pump are in accordance with our experiments. Based on this, we obtained vapor volume fraction distributions for the inducer, the impeller, and in the corresponding whole flow parts. We discovered that the vapor volume fraction of a centrifugal pump with a 3- bladed inducer is less than that of a centrifugal pump with 2- or 4-bladed inducers, which means that a centrifugal pump with a 3-bladed inducer has a better external and anti-cavitation performance.

  1. ANALYSIS OF THE PERFORMANCE OF THE BURIED PIPE GRID OF A HEAT PUMP,

    Science.gov (United States)

    An analysis is presented of experimental records obtained from a buried pipe grid of a heat pump , operated over a full heating season. The purpose of the analysis is to compare actual pipe performance with theory over a long period of time, thereby judging the applicability of the theory for practical use and to indicate the suitability of simplified design methods. (Author)

  2. Exploring heating performance of gas engine heat pump with heat recovery

    Institute of Scientific and Technical Information of China (English)

    董付江; 刘凤国; 李先庭; 尤学一; 赵冬芳

    2016-01-01

    In order to evaluate the heating performance of gas engine heat pump (GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed (1400−2600 r/min), ambient air temperature (2.4−17.8 °C) and condenser water inlet temperature (30−50 °C). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance (COP) and system primary energy ratio (PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 °C to 17.8 °C, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 °C to 50 °C. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.

  3. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    OpenAIRE

    Moo-Yeon Lee; Jong-Phil Won; Chung-Won Cho; Ho-Seong Lee

    2012-01-01

    The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volum...

  4. Performance prediction of an absorption heat pump for utilization in industry

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M.; Longo, G.A. (Padua Univ. (Italy))

    1994-01-01

    Recently, an absorption heat pump has been put on the market for industrial utilization. It is a H[sub 2]O-LiBr absorption machine which heats up water to 90[sup o]C with cold source at 40[sup o]C. The capacity and Coefficient of performance (COP) of the machine have been studied by a computer program as a function of cold source temperature and heated fluid temperature. Also, a comparison with a compression heat pump is reported. (Author)

  5. The effect of blade outlet angle on performance and internal flow condition of mini turbo-pump

    Science.gov (United States)

    Shigemitsu, T.; Fukutomi, J.; Nasada, R.; Kaji, K.

    2011-03-01

    Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields; automobile radiator pump, ventricular assist pump, cooling pump for electric devices, washing machine pump and so on. Further, the needs for mini turbo-pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini turbo-pump design is as simple as possible due to restriction to make precise manufactures. But the design method for the mini turbo-pump is not established because the internal flow condition for these small-sized fluid machineries is not clarified and conventional theory is not conductive for small-sized pumps. Three types of rotors with different outlet angles are prepared for an experiment and a numerical analysis. The performance tests are conducted with these rotors in order to investigate the effect of the blade outlet angle on performance and internal flow condition of mini turbo-pumps. It is clarified from the experimental results that head of the mini turbo-pump increases and maximum efficiency flow rate shifts to larger flow rate according to the increase of the blade outlet angle, however the maximum efficiency decreases with the increase of it. In the present paper, the performance of the mini turbo-pump is shown and the internal flow conditions are clarified with the results of the experiment and the numerical flow analysis. Furthermore, the effects of the blade outlet angle on the performance are investigated and high performance design with simple structure for the mini turbo-pump would be considered.

  6. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    Science.gov (United States)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  7. Detecting failures of the glucose sensor-insulin pump system: improved overnight safety monitoring for Type-1 diabetes.

    Science.gov (United States)

    Facchinetti, Andrea; Del Favero, Simone; Sparacino, Giovanni; Cobelli, Claudio

    2011-01-01

    New sensors for real-time continuous glucose monitoring (CGM) and pumps for continuous subcutaneous insulin infusion (CSII), possibly mounted on the same device, opened new scenarios for Type-1 diabetes treatment. However, possible failures of either CGM or CSII can expose diabetic patients to risks that can be dangerous especially overnight. In this contribution we present a proof-of-concept method, developed in a state-space context and implemented through a Kalman estimator, to detect in real time possible overnight failures of the sensor-pump system by simultaneously using CGM and CSII data. The method is tested on two simulated and one real subject. Results show that the method is able to correctly generate alerts for sensor-pump failures and stimulates further investigation on its development.

  8. Optimization on the impeller of a low-specific-speed centrifugal pump for hydraulic performance improvement

    Science.gov (United States)

    Pei, Ji; Wang, Wenjie; Yuan, Shouqi; Zhang, Jinfeng

    2016-09-01

    In order to widen the high-efficiency operating range of a low-specific-speed centrifugal pump, an optimization process for considering efficiencies under 1.0 Q d and 1.4 Q d is proposed. Three parameters, namely, the blade outlet width b 2, blade outlet angle β 2, and blade wrap angle φ, are selected as design variables. Impellers are generated using the optimal Latin hypercube sampling method. The pump efficiencies are calculated using the software CFX 14.5 at two operating points selected as objectives. Surrogate models are also constructed to analyze the relationship between the objectives and the design variables. Finally, the particle swarm optimization algorithm is applied to calculate the surrogate model to determine the best combination of the impeller parameters. The results show that the performance curve predicted by numerical simulation has a good agreement with the experimental results. Compared with the efficiencies of the original impeller, the hydraulic efficiencies of the optimized impeller are increased by 4.18% and 0.62% under 1.0 Q d and 1.4Qd, respectively. The comparison of inner flow between the original pump and optimized one illustrates the improvement of performance. The optimization process can provide a useful reference on performance improvement of other pumps, even on reduction of pressure fluctuations.

  9. Geothermal source heat pump performance for a greenhouse heating system: an experimental study

    Directory of Open Access Journals (Sweden)

    Alexandros Sotirios Anifantis

    2016-09-01

    Full Text Available Greenhouses play a significant function in the modern agriculture economy even if require great amount of energy for heating systems. An interesting solution to alleviate the energy costs and environmental problems may be represented by the use of geothermal energy. The aim of this paper, based on measured experimental data, such as the inside greenhouse temperature and the heat pump performance (input and output temperatures of the working fluid, electric consumption, was the evaluation of the suitability of low enthalpy geothermal heat sources for agricultural needs such as greenhouses heating. The study was carried out at the experimental farm of the University of Bari, where a greenhouse was arranged with a heating system connected to a ground-source heat pump (GSHP, which had to cover the thermal energy request. The experimental results of this survey highlight the capability of the geothermal heat source to ensue thermal conditions suitable for cultivation in greenhouses even if the compressor inside the heat pump have operated continuously in a fluctuating state without ever reaching the steady condition. Probably, to increase the performance of the heat pump and then its coefficient of performance within GSHP systems for heating greenhouses, it is important to analyse and maximise the power conductivity of the greenhouse heating system, before to design an expensive borehole ground exchanger. Nevertheless, according to the experimental data obtained, the GSHP systems are effective, efficient and environmental friendly and may be useful to supply the heating energy demand of greenhouses.

  10. Hydrodynamic performance of distributed pump-jet propulsion system for un- derwater vehicle

    Institute of Scientific and Technical Information of China (English)

    LÜ Xiao-jun; ZHOU Qi-dou; FANG Bin

    2014-01-01

    A type of distributed pump-jet propulsion system (DPJP) is developed with two or four specially designed pump-jet pods located around the axisymmetric underwater vehicle body symmetrically. The flow field is numerically simulated by solving the RANS equations with the finite volume method. The computational method is validated by comparing the calculated hull resistances of the SUBOFF AFF-3 model and the open water performance of a ducted propeller with experimental data. The hydrodynamic performances of the DPJP with different axial or radial positions and numbers of pump-jet pods are obtained to analyze the interactions between the hull and the pump-jet pods. It is shown in the calculated results that the decrease of the distance between the pods and the hull leads to an increase both in the efficiency of the pods and the thrust deduction factor due to the effect of the stern wake. And, a negative thrust deduction factor can be obtained by locating the DPJP at the parallel middle body near the aftbody of the vehicle to improve the hydrodynamic performance of the DPJP. Besides, the increase of the number of pods will cause a remarkable decrease of the total propulsive efficiency of the DPJP with the pods mounted on the stern planes, while a small decline of the total propulsive efficiency of the DPJP is observed with the pods mounted on the parallel middle body.

  11. Electromechanical performance analysis of inflated dielectric elastomer membrane for micro pump applications

    Science.gov (United States)

    Saini, Abhishek; Ahmad, Dilshad; Patra, Karali

    2016-04-01

    Dielectric elastomers have received a great deal of attention recently as potential materials for many new types of sensors, actuators and future energy generators. When subjected to high electric field, dielectric elastomer membrane sandwiched between compliant electrodes undergoes large deformation with a fast response speed. Moreover, dielectric elastomers have high specific energy density, toughness, flexibility and shape processability. Therefore, dielectric elastomer membranes have gained importance to be applied as micro pumps for microfluidics and biomedical applications. This work intends to extend the electromechanical performance analysis of inflated dielectric elastomer membranes to be applied as micro pumps. Mechanical burst test and cyclic tests were performed to investigate the mechanical breakdown and hysteresis loss of the dielectric membrane, respectively. Varying high electric field was applied on the inflated membrane under different static pressure to determine the electromechanical behavior and nonplanar actuation of the membrane. These tests were repeated for membranes with different pre-stretch values. Results show that pre-stretching improves the electromechanical performance of the inflated membrane. The present work will help to select suitable parameters for designing micro pumps using dielectric elastomer membrane. However this material lacks durability in operation.This issue also needs to be investigated further for realizing practical micro pumps.

  12. Numerical simulation of transient flow performance during different periods in centrifugal pump

    Institute of Scientific and Technical Information of China (English)

    HUANG Si; ZHANG Jie; ZHANG Xuejiao; SU Xianghui

    2016-01-01

    The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to simulate the transient internal flow field and the external performance of the pump during starting and stopping periods.The terms of accelerations due to variable speeds in the flow governing equations were analyzed in a multiple reference of frame (MRF).A transient CFD simulation was performed for a typical centrifugal pump by using ANSYS-CFX with the standard k-εturbulence model.The entire simulation process was composed of four stages:start-up,normal run,shutdown and post-shutdown.The function of rotating speed with regard to time was set by CEL language directly into the impeller domain in the pre-processor of the software to conduct variable speed simulation.The varia-tions of the flow field in the centrifugal pump were obtained from the transient simulation.The changing laws of flow rate,head and other performance parameters over time were also analyzed and summarized.

  13. Monitoring of Building Heating and Cooling Systems Based on Geothermal Heat Pump in Galicia (Spain

    Directory of Open Access Journals (Sweden)

    Franco D.

    2012-10-01

    Full Text Available In November 2009 was signed an agreement between Galicia’s Government and EnergyLab to develop a project related with the geothermal heatpumps (hereafter, GSHP technology. That project consisted in replacing the existing thermal equipment generators (diesel boilers and air-water heat pumps by GSHP systems in representative public buildings: two nursery schools, a university library, a health centre and a residential building. This new systems will reach the demands of existing heating, cooling and domestic hot water (hereafter, DHW. These buildings can serve as examples of energy and economic savings that can offer this technology. We will show detailed analysis of the GSHP facilities monitored, since the starting-up of them. Which includes: COP’s, EER’s, energy consumption, operating costs, operation hours of the system, economic and emissions comparative, geothermal exchange evolution graphs, environmental conditions evolution graphs (temperature and demands, etc. The results presented show an example of the important benefits of the GSHP technology and the significant savings that can offer its implementation for heating, cooling and DHW production.

  14. Monitoring of Building Heating and Cooling Systems Based on Geothermal Heat Pump in Galicia (Spain)

    Science.gov (United States)

    Iglesias, M.; Rodriguez, J.; Franco, D.

    2012-10-01

    In November 2009 was signed an agreement between Galicia's Government and EnergyLab to develop a project related with the geothermal heatpumps (hereafter, GSHP) technology. That project consisted in replacing the existing thermal equipment generators (diesel boilers and air-water heat pumps) by GSHP systems in representative public buildings: two nursery schools, a university library, a health centre and a residential building. This new systems will reach the demands of existing heating, cooling and domestic hot water (hereafter, DHW). These buildings can serve as examples of energy and economic savings that can offer this technology. We will show detailed analysis of the GSHP facilities monitored, since the starting-up of them. Which includes: COP's, EER's, energy consumption, operating costs, operation hours of the system, economic and emissions comparative, geothermal exchange evolution graphs, environmental conditions evolution graphs (temperature and demands), etc. The results presented show an example of the important benefits of the GSHP technology and the significant savings that can offer its implementation for heating, cooling and DHW production. Note to the reader: The article number has been corrected on web pages on November 22, 2013.

  15. Monitoring for vertical creep in concrete in two silos at Wivenhoe pumped storage hydro power station

    Energy Technology Data Exchange (ETDEWEB)

    Harris, M.W. [Queensland Univ. of Technology, Brisbane (Australia). School of Surveying

    1996-12-31

    The need for structural monitoring is generated by expected or unexpected (newly discovered in the life of the structure) behaviour. Due to the long vertical driveshafts involved at Wivenhoe the phenomenon of `concrete creep` which, if it is occurring, could contribute to shaft misalignment and unscheduled bearing wear or failure, was used as a motivation to establish a vertical monitoring system. The particular system developed for this site is traceable, replaceable, expandable and inexpensive. Measurements are obtained by precise levelling and the use of specially calibrated vertically suspended tapes. The analysis of the vertical loops is performed using constrained variance estimation and `robust` inter-epoch comparison. (orig.)

  16. Effect of Impeller Inlet Geometry on Cavitation Performance of Centrifugal Pumps Based on Radial Basis Function

    Directory of Open Access Journals (Sweden)

    Shuwei Zhang

    2016-01-01

    Full Text Available Aiming at the cavitation problem, the blade leading edge shape has been changed to analyze its impact on the cavitation performance for centrifugal pumps. And the response model has been established based on the Radial Basis Function. The calculation case results show that the leading edge extending forward along the shroud can improve the inlet flow condition and cavitation performance. But the cavitation performance has been reduced immensely when the leading edge extends backward along the shroud. Along with the leading edge which extends forward along the hub, the cavitation performance increases at first and then decreases. A better cavitation performance for centrifugal pumps has lower load of blade inlet and higher pressure of blade suction side. The pressure pulsation is affected by the vortex out of the impeller and the falling-off and collapsing of the cavitation bubbles. The lower the pressure pulsation for blade passing frequency and the second harmonics of the samples is, the better the cavitation performance is. A relatively accurate response model based on the Radial Basis Function has been established to predict the effect of the shape of blade leading edge on the cavitation performance of centrifugal pumps.

  17. Monitoring of aquifer pump tests with Magnetic Resonance Sounding (MRS): a synthetic case study

    DEFF Research Database (Denmark)

    Herckenrath, Daan; Auken, E.; Bauer-Gottwein, Peter

    2011-01-01

    calculates the MRS-signal generated by an aquifer pump test. A synthetic MRS-dataset was subsequently used to determine the hydrogeological parameters in an inverse parameter estimation approach. This was done for a virtual pump test with a partially and a fully penetrating well. With the MRS data we were...... able to retrieve the hydrogeological parameters of the aquifer. However, the differences in MRS signal in time were small compared to the electromagnetic noise. This limits the applicability of the MRS technique for pump tests in which a partially penetrating pumping well is used, as the limited...... drawdown around the extraction well causes smaller changes in received signal....

  18. Performance analysis of system heat pump - heat recuperator used for air treatment in process industry

    OpenAIRE

    Milovančević Uroš M.; Kosi Franc F.

    2016-01-01

    A detailed parametric analysis and performance optimization of system “heat pump - recuperator is given in this paper. Mathematical model used for analysis is formed according to the physical model of the system and practical experience. Different types of compressors, and various temperature ranges are treated. Special attention is paid to influence of condensing and evaporating temperatures on system performances, so as to different features of heat recup...

  19. Study on the effect of the impeller and diffuser blade number on reactor coolant pump performances

    Science.gov (United States)

    Long, Y.; Yin, J. L.; Wang, D. Z.; Li, T. B.

    2016-05-01

    In this paper, CFD approach was employed to study how the blade number of impeller and diffuser influences reactor coolant pump performances. The three-dimensional pump internal flow channel was modelled by pro/E software, Reynolds-averaged Naiver-Stokes equations with the k-ε turbulence model were solved by the computational fluid dynamics software CFX. By post-processing on the numerical results, the performance curves of reactor coolant pump were obtained. The results are as follows, with the blade number of the impeller increasing, the head of the pump with different diffuser universally increases in the 8Q n∼1.2Q n conditions, and at different blade number of the diffuser, the head increases with the blade number of the impeller increasing. In 1.0Q n condition, when the blades number combination of impeller and diffuser chooses 4+16, 7+14 and 6+18, the head curves exist singular points. In 1.2Q n condition, the head curve still exists singular point in 6+18. With the blade number of the impeller increasing, the efficiency of the pump with different diffuser universally decreases in the 0.8Q n and 1.0Q n conditions, but in 1.2Q n condition, the efficiency of the pump with different diffuser universally increases. In 1.0Q n condition, the impellers of 4 and 5 blades are better. When the blade number combination of impeller and diffuser choose 4+11, 4+17, 4+18, 5+12, 5+17 and 5+18, the efficiencies relatively have higher values. With the blade number of the impeller increasing, the hydraulic shaft power of the pump with different diffuser universally increases in the 0.8Q n∼1.2Q n conditions, and with the blade number of the diffuser increasing, the power of different impeller overall has small fluctuation, but tends to be uniform. This means the increase of the diffuser blade number has less influence on shaft power.The influence on the head and flow by the matching relationship of the blades number between impeller and diffuser is very complicated, which

  20. MHD interaction in an Electromagnetic Pump for high flow rate loop of ASTRID Sodium Fast Reactor secondary circuit -performances

    OpenAIRE

    Letout, S; Duterrail, Y; Fautrelle, Y; Medina, M. , il.; Rey, F.; Laffont, G.

    2015-01-01

    International audience; The present paper deals with the analysis of the performances of a very large Annular Linear Induction Pumps (ALIP) for liquid sodium. This pump is able to provide high flow rates (more than 7,000 m3.h-1 with a pressure discharge of about 3.7 bar). Dimensions of pumping channel under the active part are of an average diameter of 966 mm and a length of 4,500 mm. It’s a double sided inductor pump. On the base of an imposed 2D axisymmetric geometry, performances (discharg...

  1. Improved performance of high average power semiconductor arrays for applications in diode pumped solid state lasers

    Energy Technology Data Exchange (ETDEWEB)

    Beach, R.; Emanuel, M.; Benett, W.; Freitas, B.; Ciarlo, D.; Carlson, N.; Sutton, S.; Skidmore, J.; Solarz, R.

    1994-01-01

    The average power performance capability of semiconductor diode laser arrays has improved dramatically over the past several years. These performance improvements, combined with cost reductions pursued by LLNL and others in the fabrication and packaging of diode lasers, have continued to reduce the price per average watt of laser diode radiation. Presently, we are at the point where the manufacturers of commercial high average power solid state laser systems used in material processing applications can now seriously consider the replacement of their flashlamp pumps with laser diode pump sources. Additionally, a low cost technique developed and demonstrated at LLNL for optically conditioning the output radiation of diode laser arrays has enabled a new and scalable average power diode-end-pumping architecture that can be simply implemented in diode pumped solid state laser systems (DPSSL`s). This development allows the high average power DPSSL designer to look beyond the Nd ion for the first time. Along with high average power DPSSL`s which are appropriate for material processing applications, low and intermediate average power DPSSL`s are now realizable at low enough costs to be attractive for use in many medical, electronic, and lithographic applications.

  2. Effects of Blade Discharge Angle, Blade Number and Splitter Blade Length on Deep Well Pump Performance

    Directory of Open Access Journals (Sweden)

    E. Korkmaz

    2017-01-01

    Full Text Available Impellers with splitter blades are used for pumps and compressors in the design of turbomachines. Design parameters such as the number of blades, blade discharge angle and impeller discharge diameter impact affect pump performance and energy consumption. In this study, the effect of the number of blades (z=5, 6, and 7, blade discharge angles (β2b=25, and β2b=35 and splitter blade lengths (40, 55, 70, and 85% of the main blade length on Deep Well Pump (DWP performance has been studied experimentally. In the experiments, pump casing, blade inlet angle, blade thickness, blade width and impeller inlet and discharge diameters have been kept fixed while other parameters such as the number of blades, blade discharge angles and splitter blade lengths have been allowed to vary. As a result of the experimental study, the highest efficiency of all the impellers for best efficiency point (b.e.p has been obtained on the impeller with the number of blades z=6, blade discharge angle 2b=25 and 85% splitter blade addition compared to impellers without splitter blades.

  3. Dual-pump wave mixing in semiconductor optical amplifiers: performance enhancement with long amplifiers

    Science.gov (United States)

    Tomkos, Ioannis; Zacharopoulos, Ioannis; Syvridis, Dimitrios

    1999-05-01

    We demonstrate experimentally the improvement of the performance of the dual pump wave mixing scheme in semiconductor optical amplifiers, using long amplifier chips and high optical pump powers. The optical amplifiers used in the experiment had a ridge waveguide structure with bulk active layer and antireflective-coated angled facets. Measurements of the conversion efficiency and SBR as a function of wavelength shift are presented for a wavelength shift of more than 40 nm. The above measurements are carried out for three amplifier lengths (500 micrometers , 1000 micrometers , and 1500 micrometers ) and for different levels of the optical power of the two pumps. It will be shown that an increase in the amplifier length from 500 micrometers to 1500 micrometers results to an increase of more than 25 dB for the efficiency and more than 20 dB for the SBR. This improvement combined with the inherent advantages of the dual pump scheme (almost constant SBR and high efficiency for large wavelength shifts) results in a highly performing wavelength converter/phase conjugator, suitable for many applications.

  4. Feed-pump hydraulic performance and design improvement, Phase I: research program design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.H.; Gopalakrishnan, S.; Fehlau, R.; Thompson, W.E.; Wilson, D.G.

    1982-03-01

    As a result of prior EPRI-sponsored studies, it was concluded that a research program should be designed and implemented to provide an improved basis for the design, procurement, testing, and operation of large feed pumps with increased reliability and stability over the full range of operating conditions. This two-volume report contains a research plan which is based on a review of the present state of the art and which defines the necessary R and D program and estimates the benefits and costs of the program. The recommended research program consists of 30 interrelated tasks. It is designed to perform the needed research; to verify the results; to develop improved components; and to publish computer-aided design methods, pump specification guidelines, and a troubleshooting manual. Most of the technology proposed in the research plan is applicable to nuclear power plants as well as to fossil-fired plants. This volume contains appendixes on pump design, cavitation damage, performance testing, hydraulics, two-phase flow in pumps, flow stability, and rotor dynamics.

  5. Trailing edge devices to improve performance and increase lifetime of wind-electric water pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [USDA-Agricultural Research Service, Bushland, TX (United States)

    1996-12-31

    Trailing edge flaps were applied to the blades of a 10 kW wind turbine used for water pumping to try to improve the performance and decrease the structural fatigue on the wind turbine. Most small wind turbines (10 kW and below) use furling (rotor turns out of wind similar to a mechanical windmill) to protect the wind turbine from overspeed during high winds. Some small wind turbines, however, do not furl soon enough to keep the wind turbine from being off line part of the time in moderately high wind speeds (10 - 16 m/s). As a result, the load is disconnected and no water is pumped at moderately high wind speeds. When the turbine is offline, the frequency increases rapidly often causing excessive vibration of the wind turbine and tower components. The furling wind speed could possibly be decreased by increasing the offset between the tower centerline and the rotor centerline, but would be a major and potentially expensive retrofit. Trailing edge flaps (TEF) were used as a quick inexpensive method to try to reduce the furling wind speed and increase the on time by reducing the rotor RPM. One TEF configuration improved the water pumping performance at moderately high wind speeds, but degraded the pumping performance at low wind speeds which resulted in little change in daily water volume. The other TEF configuration differed very little from the no flap configuration. Both TEF configurations however, reduced the rotor RPM in high wind conditions. The TEF, did not reduce the rotor RPM by lowering the furling wind speed as hoped, but apparently did so by increasing the drag which also reduced the volume of water pumped at the lower wind speeds. 6 refs., 9 figs.

  6. Water Flow Performance of a Superscale Model of the Fastrac Liquid Oxygen Pump

    Science.gov (United States)

    Skelley, Stephen; Zoladz, Thomas

    2001-01-01

    As part of the National Aeronautics and Space Administration's ongoing effort to lower the cost of access to space, the Marshall Space Flight Center has developed a rocket engine with 60,000 pounds of thrust for use on the Reusable Launch Vehicle technology demonstrator slated for launch in 2000. This gas generator cycle engine, known as the Fastrac engine, uses liquid oxygen and RP-1 for propellants and includes single stage liquid oxygen and RP-1 pumps and a single stage supersonic turbine on a common shaft. The turbopump design effort included the first use and application of new suction capability prediction codes and three-dimensional blade generation codes in an attempt to reduce the turbomachinery design and certification costs typically associated with rocket engine development. To verify the pump's predicted cavitation performance, a water flow test of a superscale model of the Fastrac liquid oxygen pump was conducted to experimentally evaluate the liquid oxygen pump's performance at and around the design point. The water flow test article replicated the flow path of the Fastrac liquid oxygen pump in a 1.582x scale model, including scaled seal clearances for correct leakage flow at a model operating speed of 5000 revolutions per minute. Flow entered the 3-blade axial-flow inducer, transitioned to a shrouded, 6- blade radial impeller, and discharged into a vaneless radial diffuser and collection volute. The test article included approximately 50 total and static pressure measurement locations as well as flush-mounted, high frequency pressure transducers for complete mapping of the pressure environment. The primary objectives of the water flow test were to measure the steady-state and dynamic pressure environment of the liquid oxygen pump versus flow coefficient, suction specific speed, and back face leakage flow rate. Initial results showed acceptable correlation between the predicted and experimentally measured pump head rise at low suction specific speeds

  7. Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility

    Science.gov (United States)

    li, X. L.; Ma, X. D.; Zhu, Z. Q.; Li, Y.; Lv, K. F.

    2016-05-01

    Pump is a key sub-system which drives the heavy liquid metal circulation in experimental loops. In the paper, the hydraulic and mechanical performances of an electromagnetic pump (EMP) were tested in the liquid metal test facility named PREKY-I. The test results showed that the EMP worked at good state when the working current was up to 170 ampere. In this condition, the flow rate was 5m3/h, and pressure head 7.5bar, when the outlet temperature was kept at 380°C during the test. The performance was close to the expected design parameters. The EMP had run continuously for 200 hours with stable performance. From the test results, the EMP could be used in KYLIN-II loop, which is the upgrade liquid metal test loop of PREKY-I.

  8. Monitoring of Rotor-Stator Interaction in Pump-Turbine Using Vibrations Measured with On-Board Sensors Rotating with Shaft

    OpenAIRE

    Cristian G. Rodriguez; Borja Mateos-Prieto; Eduard Egusquiza

    2014-01-01

    Current trends in design of pump-turbines have led into higher rotor-stator interaction (RSI) loads over impeller-runner. These dynamic loads are of special interest having produced catastrophic failures in pump-turbines. Determining RSI characteristics facilitates the proposal of actions that will prevent these failures. Pressure measurements all around the perimeter of the impeller-runner are appropriate to monitor and detect RSI characteristics. Unfortunately most installed pump-turbines a...

  9. Performance monitoring of a multi-unit solar domestic hot water system

    Energy Technology Data Exchange (ETDEWEB)

    Makuch, P.D.; Harrison, S.J. [Queen`s Univ., Kingston, ON (Canada). Solar Calorimetry Lab.

    1994-12-01

    A solar domestic hot water (SDHW) system was installed on an existing multi-family apartment building in 1991. Energy monitoring hardware was installed in 1992. It was a preheat system that was retrofitted upstream of existing hot water tanks located in the building. Monitoring of the system continued for eight months. As a result of this monitoring, average daily values could be made available for each month, as well as values of incident solar radiation, outdoor temperature, hot water use, total system energy, auxiliary energy, solar energy delivered to the load, energy loss from the recirculation loop and pump run time. Performance results indicated that the system performed at a level close to simulated values, but that system performance during the summer period was severely reduced due to low hot water usage. 5 refs., 12 figs., 2 tabs.

  10. Research on the performance of low-lift diving tubular pumping system by CFD and Test

    Science.gov (United States)

    Xia, Chenzhi; Cheng, Li; Liu, Chao; Zhou, Jiren; Tang, Fangping; Jin, Yan

    2016-11-01

    Post-diving tubular pump is always used in large-discharge & low-head irrigation or storm drainage pumping station, its impeller and motor share the same shaft. Considering diving tubular pump system's excellent hydraulic performance, compact structure, good noise resistance and low operating cost, it is used in Chinese pump stations. To study the hydraulic performance and pressure fluctuation of inlet and outlet passage in diving tubular pump system, both of steady and unsteady full flow fields are numerically simulated at three flow rate conditions by using CFD commercial software. The asymmetry of the longitudinal structure of inlet passage affects the flow pattern on outlet. Especially at small flow rate condition, structural asymmetry will result in the uneven velocity distribution on the outlet of passage inlet. The axial velocity distribution uniformity increases as the flow rate increases on the inlet of passage inlet, and there is a positive correlation between hydraulic loss in the passage inlet and flow rate's quadratic. The axial velocity distribution uniformity on the outlet of passage inlet is 90% at design flow rate condition. The predicted result shows the same trend with test result, and the range of high efficiency area between predicted result and test result is almost identical. The dominant frequency of pressure pulsation is low frequency in inlet passage at design condition. The dominant frequency is high frequency in inlet passage at small and large flow rate condition. At large flow rate condition, the flow pattern is significantly affected by the rotation of impeller in inlet passage. At off-design condition, the pressure pulsation is strong at outlet passage. At design condition, the dominant frequency is 35.57Hz, which is double rotation frequency.

  11. Monitoring and modelling of pumping-induced self-potentials for transmissivity estimation within a heterogeneous confined aquifer

    Science.gov (United States)

    DesRoches, Aaron J.; Butler, Karl E.

    2016-12-01

    Variations in self-potentials (SP) measured at surface during pumping of a heterogeneous confined fractured rock aquifer have been monitored and modelled in order to investigate capabilities and limitations of SP methods in estimating aquifer hydraulic properties. SP variations were recorded around a pumping well using an irregular grid of 31 non-polarizing Pb-PbCl2 that were referenced to a remote electrode and connected to a commercial multiplexer and digitizer/data logger through a passive lowpass filter on each channel. The lowpass filter reduced noise by a factor of 10 compared to levels obtained using the data logger's integration-based sampling method for powerline noise suppression alone. SP signals showed a linear relationship with water levels observed in the pumping and monitoring wells over the pumping period, with an apparent electrokinetic coupling coefficient of -3.4 mV · m-1. Following recent developments in SP methodology, variability of the SP response between different electrodes is taken as a proxy for lateral variations in hydraulic head within the aquifer and used to infer lateral variations in the aquifer's apparent transmissivity. In order to demonstrate the viability of this approach, SP is modelled numerically to determine its sensitivity to (i) lateral variations in the hydraulic conductivity of the confined aquifer and (ii) the electrical conductivity of the confining layer and conductive well casing. In all cases, SP simulated on the surface still varies linearly with hydraulic head modelled at the base on the confining layer although the apparent coupling coefficient changes to varying degrees. Using the linear relationship observed in the field, drawdown curves were inferred for each electrode location using SP variations observed over the duration of the pumping period. Transmissivity estimates, obtained by fitting the Theis model to inferred drawdown curves at all 31 electrodes, fell within a narrow range of (2.0-4.2) × 10-3 m2

  12. Performance analysis of axial flow pump on gap changing between impeller and guide vane

    Science.gov (United States)

    Wang, W. J.; Liang, Q. H.; Wang, Y.; Yang, Y.; Yin, G.; Shi, X. X.

    2013-12-01

    In order to study the influence on gap changing of the static and dynamic components in axial flow pump, the axial flow pump model (TJ04-ZL-06) that used in the eastern of south-to-north water diversion project was selected. Steady turbulence field with different gaps was simulated by standard κ-ε turbulence model and double-time stepping methods. Information on the pressure distribution and velocity distribution of impeller surfaces were obtained. Then, calculated results were compared with the test results and analyzed. The results show that the performance of pump is not sensitive with the axial gap width under design conditions and the large flow rate condition. With increasing gap width, it will be improved in low flow rate condition. The attack angle of impeller inlet in small flow rate condition become small and the flow separation phenomenon can be observed in this condition. The axial velocity distribution of impeller outlet is nonlinear and to increase the axial gap is to improve the flow pattern near the hub effectively. The trend of calculating results is identical with test. It will play a guiding role to the axial pump operation and design in south-to-north water diversion project.

  13. Performance Analysis of a Wind Turbine Driven Swash Plate Pump for Large Scale Offshore Applications

    Science.gov (United States)

    Buhagiar, D.; Sant, T.

    2014-12-01

    This paper deals with the performance modelling and analysis of offshore wind turbine-driven hydraulic pumps. The concept consists of an open loop hydraulic system with the rotor main shaft directly coupled to a swash plate pump to supply pressurised sea water. A mathematical model is derived to cater for the steady state behaviour of entire system. A simplified model for the pump is implemented together with different control scheme options for regulating the rotor shaft power. A new control scheme is investigated, based on the combined use of hydraulic pressure and pitch control. Using a steady-state analysis, the study shows how the adoption of alternative control schemes in a the wind turbine-hydraulic pump system may result in higher energy yields than those from a conventional system with an electrical generator and standard pitch control for power regulation. This is in particular the case with the new control scheme investigated in this study that is based on the combined use of pressure and rotor blade pitch control.

  14. Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer.

    Science.gov (United States)

    Schultze, Volkmar; Ijsselsteijn, Rob; Scholtes, Theo; Woetzel, Stefan; Meyer, Hans-Georg

    2012-06-18

    We compare the performance of two methods for the synchronization of the atomic spins in optically pumped magnetometers: intensity modulation of the pump light and the classical M(x) method using B(1) field modulation. Both techniques use the same set-up and measure the resulting features of the light after passing a micro-fabricated Cs cell. The intensity-modulated pumping shows several advantages: better noise-limited magnetic field sensitivity, misalignment between pumping and spin synchronization is excluded, and magnetometer arrays without any cross-talk can be easily set up.

  15. Remote monitoring of LED lighting system performance

    Science.gov (United States)

    Thotagamuwa, Dinusha R.; Perera, Indika U.; Narendran, Nadarajah

    2016-09-01

    The concept of connected lighting systems using LED lighting for the creation of intelligent buildings is becoming attractive to building owners and managers. In this application, the two most important parameters include power demand and the remaining useful life of the LED fixtures. The first enables energy-efficient buildings and the second helps building managers schedule maintenance services. The failure of an LED lighting system can be parametric (such as lumen depreciation) or catastrophic (such as complete cessation of light). Catastrophic failures in LED lighting systems can create serious consequences in safety critical and emergency applications. Therefore, both failure mechanisms must be considered and the shorter of the two must be used as the failure time. Furthermore, because of significant variation between the useful lives of similar products, it is difficult to accurately predict the life of LED systems. Real-time data gathering and analysis of key operating parameters of LED systems can enable the accurate estimation of the useful life of a lighting system. This paper demonstrates the use of a data-driven method (Euclidean distance) to monitor the performance of an LED lighting system and predict its time to failure.

  16. Instrument Performance Monitoring at Gemini North

    Science.gov (United States)

    Emig, Kimberly; Pohlen, M.; Chene, A.

    2014-01-01

    An instrument performance monitoring (IPM) project at the Gemini North Observatory evaluates the delivered throughput and sensitivity of, among other instruments, the Near-Infrared Integral Field Spectrometer (NIFS), the Gemini Near-Infrared Spectrograph (GNIRS), and the Gemini Multi-Object Spectrograph (GMOS-N). Systematic observations of standard stars allow the quality of the instruments and mirror to be assessed periodically. An automated pipeline has been implemented to process and analyze data obtained with NIFS, GNIRS cross-dispersed (XD) and long slit (LS) modes, and GMOS (photometry and spectroscopy). We focus the discussion of this poster on NIFS and GNIRS. We present the spectroscopic throughput determined for ZJHK bands on NIFS, the XJHKLM band for GNIRS XD mode and the K band for GNIRS LS. Additionally, the sensitivity is available for the JHK bands in NIFS and GNIRS XD, and for the K band in GNIRS LS. We consider data taken as early as March 2011. Furthermore, the pipeline setup and the methods used to determine throughput and sensitivity are described.

  17. High-performance genetically targetable optical neural silencing by light-driven proton pumps.

    Science.gov (United States)

    Chow, Brian Y; Han, Xue; Dobry, Allison S; Qian, Xiaofeng; Chuong, Amy S; Li, Mingjie; Henninger, Michael A; Belfort, Gabriel M; Lin, Yingxi; Monahan, Patrick E; Boyden, Edward S

    2010-01-07

    The ability to silence the activity of genetically specified neurons in a temporally precise fashion would provide the opportunity to investigate the causal role of specific cell classes in neural computations, behaviours and pathologies. Here we show that members of the class of light-driven outward proton pumps can mediate powerful, safe, multiple-colour silencing of neural activity. The gene archaerhodopsin-3 (Arch) from Halorubrum sodomense enables near-100% silencing of neurons in the awake brain when virally expressed in the mouse cortex and illuminated with yellow light. Arch mediates currents of several hundred picoamps at low light powers, and supports neural silencing currents approaching 900 pA at light powers easily achievable in vivo. Furthermore, Arch spontaneously recovers from light-dependent inactivation, unlike light-driven chloride pumps that enter long-lasting inactive states in response to light. These properties of Arch are appropriate to mediate the optical silencing of significant brain volumes over behaviourally relevant timescales. Arch function in neurons is well tolerated because pH excursions created by Arch illumination are minimized by self-limiting mechanisms to levels comparable to those mediated by channelrhodopsins or natural spike firing. To highlight how proton pump ecological and genomic diversity may support new innovation, we show that the blue-green light-drivable proton pump from the fungus Leptosphaeria maculans (Mac) can, when expressed in neurons, enable neural silencing by blue light, thus enabling alongside other developed reagents the potential for independent silencing of two neural populations by blue versus red light. Light-driven proton pumps thus represent a high-performance and extremely versatile class of 'optogenetic' voltage and ion modulator, which will broadly enable new neuroscientific, biological, neurological and psychiatric investigations.

  18. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  19. Study on Improving Suction Performance of Centrifugal Pump in Pump Well%改善机井离心泵吸水性能的研究

    Institute of Scientific and Technical Information of China (English)

    刘建华; 尚四青

    2014-01-01

    针对河南省清丰县某井灌区由于机井水位下降而造成机井离心泵无法正常工作的问题,对离心泵进行了全面的检测,并结合该井灌区的相关水文资料以及井、泵的性能参数分析,提出了改造离心泵以改善机井离心泵吸水性能的措施,即利用射流技术改善机井离心泵吸水性能。根据井、泵参数设计了射流装置,通过灌区应用,达到了预期目标,该方案为灌溉设备的改造提供了有效的参考。%We did comprehensive test on centrifugal pump ,because water level dropped in a well irrigation area of Qingfeng country in Henan ,which made the centrifugal pump working abnormally .The measure for transforming centrifugal pump ,which was jet flow technology ,to improve suction performance of the shaft centrifugal pump were put forward ,after analyzing the related hydrological data of this area and performance parameters of the well and pump .So we designed a fluidic device according to the performance parameters of well and pump ,and application reached the expected goal .The scheme provides effective reference for reconstruction of irrigation equipment .

  20. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S.; Dyer, James D.; Martinez Morales, Carlos A.

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  1. GPRS wireless data terminal for heat pump remote monitoring%面向热泵机组远程监控的GPRS无线数据终端

    Institute of Scientific and Technical Information of China (English)

    周澍; 王剑; 徐平; 姜周曙

    2011-01-01

    In order to solve the problem of the centralized management of multiple-unit heat pump, the wireless communication technology based on general packet radio service(GPRS) networks was applied to the remote monitoring of heat pump units, and a set of GPRS wireless data transmission terminal based on air source heat pump units was designed. High-performance microcontroller, STM32F103 was taken,which has a Cortex_M3 kernel as the core monitoring unit, and Huawei GPRS module, EM310 was taken, as the communication module to achieve the data communication function. The data communication is based on TCP / IP protocol. In order to improve the reliability of the heat pump remote monitoring, a data transfer protocol of application layer data was proposed and the corresponding software program was developed. Research results show that this remote monitoring programs has features of lower cost, smaller size, higher transmission speed and less wiring. Moreover, it has high promotion value.%为了解决热泵多机组的集中管理问题,将基于通用分组无线业务(GPRS)网络的无线通信技术应用于热泵机组的远程监控中;设计了一套面向空气源热泵机组远程数据传输的GPRS无线数据传输终端.该装置采用Cortex_M3内核的高性能单片机STM32F103作为核心测控元件;采用华为GPRS模块EM310作为通信模块,完成基于TCP/IP协议的数据通信.为了提高热泵远程监控的可靠性,提出了一种针对热泵数据特点的应用层无线数据传输协议和相应的软件方案.研究结果表明,该方案具有成本低、体积小、传输速度高、布线少等特点,具有较高推广价值.

  2. Flow Pattern Analysis and Performance Improvement of Regenerative Flow Pump Using Blade Geometry Modification

    Directory of Open Access Journals (Sweden)

    J. Nejadrajabali

    2016-01-01

    Full Text Available Regenerative pump is a low specific speed and rotor-dynamic turbomachine capable of developing high heads at low flow rates. In this paper, a numerical study has been carried out in order to investigate the effect of blade angle on the performance of a regenerative pump. Two groups of impellers were employed. The first type has symmetric angle blades with identical inlet/outlet angles of ±10°, ±30°, and ±50° and the second group has nonsymmetric angle blades in which the inlet angle was set to 0° and six different angles of ±10°, ±30°, and ±50° were designed for the outlet of the blades. A total of 12 impellers, as well as primary radial blades impeller, were investigated in this study. The results showed that all forward blades have higher head coefficients than radial blades impeller at design flow coefficient. It was found that regenerative pumps with symmetric angle forward blades have better performance than other types. Also, it is worth mentioning that the highest head coefficient and efficiency occur at angle +10<β<+30 of symmetric angle blades. It was found that the maximum efficiency occurs at angle of +15.5° by curve fitting to the data obtained from numerical simulations for symmetric angle forward blades.

  3. Performance evaluation of heat pump system using R744/R161 mixture refrigerant

    Directory of Open Access Journals (Sweden)

    Zhang Xian-Ping

    2014-01-01

    Full Text Available As an efficient and energy conservation technology, heat pumps working with R22, which are scheduled to be phased out by Montreal Protocol, are widely used in China at present. The global deteriorating ecology environment would accelerate the phase-out time of R22 in developing countries. Therefore, as a matter of urgency, an eco-friendly substitute should be investigated in order to replace R22. Under this context, and with a consideration of the environmental protection, R744/R161 mixture refrigerant is proposed. R744/R161 mixture refrigerant’s condensation pressure is reduced and its flammability and explosivity are suppressed. A thermodynamic model is developed, and under the given working conditions, the performances of subcritical heat pump system using R744/R161 mixture of variable mass fraction are discussed and compared with those of the R22 system. The optimal mass fraction of R744/R161 is given, which corresponds to a maximal heating coefficient of performance. The simulation results show that R744/R161 mixture can work as a competitive alternative to R22 in heat pump system.

  4. Multi-point optimization on meridional shape of a centrifugal pump impeller for performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Ji; Wang, Wen Jie; Yuan, Shouqi [National Research Center of Pumps, Jiangsu University, Zhenjiang (China)

    2016-11-15

    A wide operating band is important for a pump to safely perform at maximum efficiency while saving energy. To widen the operating range, a multi-point optimization process based on numerical simulations in order to improve impeller performance of a centrifugal pump used in nuclear plant applications is proposed by this research. The Reynolds average Navier Stokes equations are utilized to perform the calculations. The meridional shape of the impeller was optimized based on the following four parameters; shroud arc radius, hub arc radius, shroud angle, and hub angle as the design variables. Efficiencies calculated under 0.6Qd, 1.0Qd and 1.62Qd were selected as the three optimized objectives. The Design of experiment method was applied to generate various impellers while 35 impellers were generated by the Latin hypercube sampling method. A Response surface function based on a second order function was applied to construct a mathematical relationship between the objectives and design variables. A multi-objective genetic algorithm was utilized to solve the response surface function to obtain the best optimized objectives as well as the best combination of design parameters. The results indicated that the pump performance predicted by numerical simulation was in agreement with the experimental performance. The optimized efficiencies based on the three operating conditions were increased by 3.9 %, 6.1 % and 2.6 %, respectively. In addition, the velocity distribution, pressure distribution, streamline and turbulence kinetic energy distribution of the optimized and reference impeller were compared and analyzed to illustrate the performance improvement.

  5. Bearing gap adjustment for improvement of levitation performance in a hydrodynamically levitated centrifugal blood pump.

    Science.gov (United States)

    Kosaka, Ryo; Yoshida, Fumihiko; Nishida, Masahiro; Maruyama, Osamu; Kawaguchi, Yasuo; Yamane, Takashi

    2015-01-01

    The purpose of the present study is to investigate a bearing gap adjustment for improvement of levitation performance in a hydrodynamically levitated centrifugal blood pump to realize a blood pump with a low hemolysis level. The impeller levitates axially by balancing a gravitational force, buoyancy, a magnetic force, and hydrodynamic forces on the top and bottom sides of the impeller. To adjust the levitation position of the impeller, the balance of acting forces on the impeller was adjusted by changing the shroud area on the bottom impeller. Three pumps having various shroud area were prepared as tested models: 817 mm(2) (HH-S), 875 mm(2) (HH-M) and 931 mm(2) (HH-L). First, for evaluating the bearing gap adjustment, the bearing gap was estimated by calculating a balancing position of the acting forces on the impeller. We actually measured the gravitational force, buoyancy and the magnetic force, and numerically analyzed hydrodynamic forces on the top and bottom sides of the impeller. Second, to verify accuracy of the estimated bearing gap, the measurement test of the bearing gap was performed. Finally, an in-vitro hemolysis test was performed to evaluate a hemolysis level of the pump. As a result, bottom bearing gaps were estimated as 40 μm (HH-S), 60 μm (HH-M) and 238 μm (HH-L). In the measurement test, bottom bearing gaps were measured as 63 μm (HH-S), 219 μm (HH-M), and 231 μm (HH-L). The estimated bearing gaps had positively correlated with the measured bearing gaps in relation to the shroud area on the impeller. In the hemolysis test, hemolysis level in every model was almost equivalent to that of BPX-80, when the bearing gap was adjusted greater than 60 μm. We could adjust the bearing gap by changing the shroud area on the impeller for improvement of levitation performance to realize a blood pump with a low hemolysis level.

  6. Ramadan fasting in diabetes patients on insulin pump therapy augmented by continuous glucose monitoring: an observational real-life study.

    Science.gov (United States)

    Khalil, Ali Bernard; Beshyah, Salem A; Abu Awad, Samar M; Benbarka, Mahmoud M; Haddad, Marcil; Al-Hassan, Dana; Kahwatih, Marwa; Nagelkerke, Nico

    2012-09-01

    Hypoglycemia during the daytime of Ramadan fasting is the most feared complication of diabetes. Insulin pump therapy has been proposed as the ideal "theoretical" method for insulin delivery. We report a prospective observational, single-center study of insulin-treated patients using insulin pump therapy during Ramadan 2011. Twenty-one patients (10 males and 11 females) were selected; median age was 26 years. They adjusted their insulin as per their usual practices. Outcome measures obtained before and during Ramadan included body weight, glycosylated hemoglobin, blood glucose, total insulin dose differences, overriding tendency, suspension time during fasting, and number of hypoglycemic episodes. The patients fasted for a median of 29 days. The observed changes during Ramadan were overall not significant quantitatively, but some trends were noted. The total insulin administered during Ramadan was not different from that in the pre-Ramadan period, but there was a redistribution of insulin over a 24-h period in relation to the changes in the daily lifestyle and eating patterns. Basal insulin was decreased during the daytime by 5-20% from before Ramadan and increased during the nighttime. The mean change in the overall amount of basal insulin was not significant. A larger than usual amount of insulin bolus was given at the meals Iftar, Fowala, and Suhur; the change in the total amount of bolus insulin as a percentage change from total insulin was also not significant. No major hypoglycemic episodes were reported. Minor hypoglcemic episodes were equally distributed between daytime and nighttime and were managed by either basal insulin adjustment or suspension from the pump. This study confirms the advantages provided by insulin pump use in patients with diabetes were enhanced by the use of continuous glucose monitoring. We provided more evidence-based advice on how best to adjust the insulin pump during fasting.

  7. Advanced performance of small diaphragm vacuum pumps through the use of mechatronics

    Science.gov (United States)

    Lachenmann, R.; Dirscherl, J.

    Oil-free diaphragm vacuum pumps have proven to be the best way in vacuum generation for the chemical laboratory and they also find increasing use as backing pumps for modern wide-range turbo molecular pumps. The majority of vacuum pumps in practical use pump only a rather small percentage of their lifetime at full gas load. A pump backing a turbo molecular pump does not have to pump a significant gas load when the high-vacuum pump is running at ultimate vacuum pressure. Also, for a vacuum distillation the vacuum pump has to operate at full speed only at the beginning to lower the pressure inside the system to a vacuum level where evaporation starts. In a rather leak-tight system the distillation process continues by evaporating from the hot liquid and condensing at the cold condenser without the need of a mechanical vacuum pump. Rotational speed controlled diaphragm pumps are now available through progress in mechatronics and offer high pumping speed capability for fast pump-down cycles and precise pressure control for distillations. At low gas load the rotational speed can be reduced, improving maintenance intervals, power consumption, noise, vibration and - surprisingly - also ultimate pressure. The different behaviour in pumping speed and ultimate pressure of rotational speed controlled diaphragm pumps in comparison to constant-speed pumps is related to the mechanical properties of the valves and gas dynamics .

  8. Performance analysis of system heat pump - heat recuperator used for air treatment in process industry

    Directory of Open Access Journals (Sweden)

    Milovančević Uroš M.

    2016-01-01

    Full Text Available A detailed parametric analysis and performance optimization of system “heat pump - recuperator is given in this paper. Mathematical model used for analysis is formed according to the physical model of the system and practical experience. Different types of compressors, and various temperature ranges are treated. Special attention is paid to influence of condensing and evaporating temperatures on system performances, so as to different features of heat recuperator. It is found out that in accordance to the working regimes and the compressor type, it is possible to determine optimal conditions in which the system will consume the minimum of electricity.

  9. Contribution of variable-speed pump hydro storage for power system dynamic performance

    Science.gov (United States)

    Silva, B.; Moreira, C.

    2017-04-01

    This paper presents the study of variable-speed Pump Storage Powerplant (PSP) in the Portuguese power system. It evaluates the progressive integration in three major locations and compares the power system performance following a severe fault event with consequent disconnection of non-Fault Ride-through (FRT) compliant Wind Farms (WF). To achieve such objective, a frequency responsive model was developed in PSS/E and was further used to substitute existing fixed-speed PSP. The results allow identifying a clear enhancement on the power system performance by the presence of frequency responsive variable-speed PSP, especially for the scenario presented, with high level of renewables integration.

  10. Comparison of performance between a parallel and a series solar-heat pump system; Solar heat pump system ni okeru heiretsu setsuzoku no seino hikaku

    Energy Technology Data Exchange (ETDEWEB)

    Kanayama, K.; Zhao, J.; Baba, H.; Endo, N. [Kitami Institute of Technology, Hokkaido (Japan)

    1997-11-25

    In a solar heat pump system, a single-tank system was fabricated, in which a heat pump is installed in series between a heat collecting tank and a heat storage tank. At the same time, a double-tank system was also fabricated, in which two tanks are assembled into one to which a solar system and a heat pump are connected in parallel. Performance of both systems was analyzed by using measured values and estimated values. Heat collecting efficiency in the double-tank system is higher by about 13 points than in the single-tank system. Nevertheless, the coefficient of performance for the single-tank system is 1.03 to 1.51 times greater than that of the double-tank system. Dependency of the single-tank system on natural energy is higher by 0.3 to 3 points than the double-tank system. Putting the above facts together, it may be said that the single-tank system connecting the solar system and the heat pump in parallel is superior in performance to the double-tank system of the series connection. 3 refs., 5 figs., 2 tabs.

  11. Proton pump inhibitors for reflux therapy in infants: effectiveness determined by impedance pH monitoring.

    Science.gov (United States)

    Castellani, Christoph; Huber-Zeyringer, Andrea; Bachmaier, Gerhard; Saxena, Amulya K; Höllwarth, Michael E

    2014-04-01

    To evaluate the influence of proton pump inhibitors (PPI) in predominantly milk-fed infants with symptoms of GERD by 24-h pH-multichannel intraluminal impedance (24-h pH-MII). Ten infants (8 males and 2 females) with a mean gestational age of 39 weeks (28-40) were included. 24-h pH-MII was performed before prescription and during intake of PPI. Total acid exposure time, bolus exposure time (acidic/non-acidic/total) and the number of refluxes (acidic/non-acidic/total) were determined. Clinical symptoms were recorded and used to calculate the Reflux Symptom Index (RSI) and the Symptom Severity Index (SSI). There was a significant decrease in the number of acidic refluxes, total acid exposure and acidic bolus exposure time. However, this went along with a significant increase in non-acidic bolus exposure time. The total number of refluxes and the total bolus exposure time remained unchanged. Under PPI, a decrease of SSI and RSI for pain-related symptoms could be observed. For respiratory symptoms and vomiting however no significant changes could be demonstrated. Under PPI, an improvement of pain-related symptoms could be shown. The decrease of acid exposure went along with an increase of non-acidic refluxes resulting in almost constant total reflux numbers. This finding is interpreted as main reason for some persisting symptoms despite adequate PPI dosage. Concluding from our data PPI therapy should only be indicated in case of pain, but has no effect in case of vomiting or recurrent respiratory symptoms.

  12. Wearable electrochemical sensors for monitoring performance athletes

    Science.gov (United States)

    Fraser, Kevin J.; Curto, Vincenzo F.; Coyle, Shirley; Schazmann, Benjamin; Byrne, Robert; Benito-Lopez, Fernando; Owens, Róisín M.; Malliaras, George G.; Diamond, Dermot

    2011-10-01

    Nowadays, wearable sensors such as heart rate monitors and pedometers are in common use. The use of wearable systems such as these for personalized exercise regimes for health and rehabilitation is particularly interesting. In particular, the true potential of wearable chemical sensors, which for the real-time ambulatory monitoring of bodily fluids such as tears, sweat, urine and blood has not been realized. Here we present a brief introduction into the fields of ionogels and organic electrochemical transistors, and in particular, the concept of an OECT transistor incorporated into a sticking-plaster, along with a printable "ionogel" to provide a wearable biosensor platform.

  13. Performance study of a heat pump dryer system for speciality crops - Pt. 2: model verification

    Energy Technology Data Exchange (ETDEWEB)

    Adapa, P.K.; Schoenau, G.J.; Sokhansanj, S. [University of Saskatchewan (Canada). College of Engineering

    2002-07-01

    The experimental and predicted performance data of a heat pump dryer system is reported. Chopped alfalfa was dried in a cabinet dryer in batches and also by emulating continuous bed drying using two heat pumps operating in parallel. Results showed that alfalfa was dried from an initial moisture content of 70% (wb) to a final moisture content of 10% (wb). The batch drying took about 4.5 h while continuous bed drying took 4 h to dry the same amount of material. The average air velocity inside the dryer was 0.36 m s{sup -1}. Low temperatures (30-45{sup o}C) for safe drying of specialty crops were achieved experimentally. The heat pump drying system used in this study was about 50% more efficient in recovering the latent heat from the dryer exhaust compared to the conventional dryers. Specific moisture extraction rate (SMER) was maximum when relative humidity stayed above 40%. The dryer was shown to be capable of SMER of between 0.5 and 1.02 kg kW{sup -1} h{sup -1}. It was concluded that continuous bed drying is potentially a better option than batch drying because high process air humidity ratios at the entrance of the evaporator and constant moisture extraction rate and specific moisture extraction rate values can be maintained. An uncertainty analysis confirmed the accuracy of the model. (author)

  14. Enhanced Component Performance Study: Motor-Driven Pumps 1998–2014

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified in pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, and run hours per reactor year for runs of less than or equal to one hour.

  15. Performance Study of Thermoelectric Solar-Assisted Heat Pump with Reflectors

    Science.gov (United States)

    Lertsatitthanakorn, C.; Soponronnarit, S.; Jamradloedluk, J.; Rungsiyopas, M.; Sarachitti, R.

    2014-06-01

    The simultaneous conversion of solar radiation into thermal and electrical energy in a thermoelectric (TE) solar-assisted heat pump is, for the purposes of this study, referred to as hybrid conversion. To capture more thermal and electrical energy, flat-plate reflectors have been mounted on a TE solar collector. To obtain higher solar radiation intensity on the TE solar collector, the position of the reflectors has been changed and the optimal position of the reflectors determined by both experimental measurements and numerical calculation so as to obtain maximal concentration of solar radiation intensity. The calculated values have been found to be in good agreement with measured ones. Improvements to the thermal energy and electrical power outputs of the system can be achieved by the use of the TE solar-assisted heat pump with reflectors. For the optimum position of the reflectors, the coefficient of performance (COP) of the system formed from a TE solar collector integrated with a heat pump (TESC-HP) was 5.60. The power output and conversion efficiency of the TE modules can reach 10.09 W and 2.40%, respectively, being improved by 34.5% and 18.2%, respectively, compared with the TESC-HP without reflectors.

  16. Enhanced Component Performance Study: Motor-Driven Pumps 1998–2013

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to 1 hour, and failure to run more than 1 hour; for normally running systems, the failure modes considered are failure to start and failure to run. An 8 hr unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant increasing trend was identified in the standby pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, run hours per reactor year for runs of less than or equal to 1 hour, and frequency of fail to start events per reactor year.

  17. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.

    Science.gov (United States)

    Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro

    2015-12-01

    Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  18. Parental Monitoring and Child Performance in Ghana

    Science.gov (United States)

    Gyamfi, Kwadwo; Pobbi, Michael Asamani

    2016-01-01

    The role of parents in the guiding and monitoring of child activities is critical towards the development of the child. In Ghana reforms taken, especially at the basic school level, have focused on improving school infrastructure and enrollment ignoring parents awareness to actively involve themselves both at home and in school activities which…

  19. Method and apparatus for monitoring machine performance

    Science.gov (United States)

    Smith, Stephen F.; Castleberry, Kimberly N.

    1996-01-01

    Machine operating conditions can be monitored by analyzing, in either the time or frequency domain, the spectral components of the motor current. Changes in the electric background noise, induced by mechanical variations in the machine, are correlated to changes in the operating parameters of the machine.

  20. Investigation of the performance of individual sorption components of a novel thermally driven heat pump for solar applications

    OpenAIRE

    Blackman, Corey

    2014-01-01

    An enhanced-modularity thermally driven chemical heat pump was conceptualised as a second generation product for various heating and cooling applications with special emphasis on solar applications. The typical characteristics of the absorption heat pump were studied and the key performance parameters were selected for further investigation. An experimental test rig was constructed to allow for the testing of each component’s performance characteristics with special attention being paid to th...

  1. Performance evaluation of salivary amylase activity monitor.

    Science.gov (United States)

    Yamaguchi, Masaki; Kanemori, Takahiro; Kanemaru, Masashi; Takai, Noriyasu; Mizuno, Yasufumi; Yoshida, Hiroshi

    2004-10-15

    In order to quantify psychological stress and to distinguish eustress and distress, we have been investigating the establishment of a method that can quantify salivary amylase activity (SMA). Salivary glands not only act as amplifiers of a low level of norepinephrine, but also respond more quickly and sensitively to psychological stress than cortisol levels. Moreover, the time-course changes of the salivary amylase activity have a possibility to distinguish eustress and distress. Thus, salivary amylase activity can be utilized as an excellent index for psychological stress. However, in dry chemistry system, a method for quantification of the enzymatic activity still needs to be established that can provide with sufficient substrate in a testing tape as well as can control enzymatic reaction time. Moreover, it is necessary to develop a method that has the advantages of using saliva, such as ease of collection, rapidity of response, and able to use at any time. In order to establish an easy method to monitor the salivary amylase activity, a salivary transcription device was fabricated to control the enzymatic reaction time. A fabricated salivary amylase activity monitor consisted of three devices, the salivary transcription device, a testing-strip and an optical analyzer. By adding maltose as a competitive inhibitor to a substrate Ga1-G2-CNP, a broad-range activity testing-strip was fabricated that could measure the salivary amylase activity with a range of 0-200 kU/l within 150 s. The calibration curve of the monitor for the salivary amylase activity showed R2=0.941, indicating that it was possible to use this monitor for the analysis of the salivary amylase activity without the need to determine the salivary volume quantitatively. In order to evaluate the assay variability of the monitor, salivary amylase activity was measured using Kraepelin psychodiagnostic test as a psychological stressor. A significant difference of salivary amylase activity was recognized

  2. Theoretical study on volatile organic compound removal and energy performance of a novel heat pump assisted solid desiccant cooling system

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Zhang, Ge

    2015-01-01

    A theoretical model was established for predicting the volatile organic compound (VOC) removal and energy performance of a novel heat pump assisted solid desiccant cooling system (HP-SDC). The HP-SDC was proposed based on the combination of desiccant rotor with heat pump, and was designed...... for cooling, dehumidification and indoor air cleaning in normal office, commercial or residential buildings. The desiccant rotor was used for dehumidification and indoor air cleaning; the heat pump provided sensible cooling and regeneration heat for the desiccant rotor. The theoretical model consisted of two...... sub-models. One sub-model was used to simulate the heat, moisture and VOC transfer in the desiccant rotor; the other sub-model was used to predict the energy performance of the heat pump. Combining the two sub-models, the energy performance and VOC removal effect of the HP-SDC could be simulated...

  3. 36 CFR 1207.40 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Monitoring and reporting program performance. 1207.40 Section 1207.40 Parks, Forests, and Public Property NATIONAL ARCHIVES AND... and that performance goals are being achieved. Grantee monitoring must cover each program, function...

  4. Computer simulation of steady-state performance of air-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Ellison, R D; Creswick, F A

    1978-03-01

    A computer model by which the performance of air-to-air heat pumps can be simulated is described. The intended use of the model is to evaluate analytically the improvements in performance that can be effected by various component improvements. The model is based on a trio of independent simulation programs originated at the Massachusetts Institute of Technology Heat Transfer Laboratory. The three programs have been combined so that user intervention and decision making between major steps of the simulation are unnecessary. The program was further modified by substituting a new compressor model and adding a capillary tube model, both of which are described. Performance predicted by the computer model is shown to be in reasonable agreement with performance data observed in our laboratory. Planned modifications by which the utility of the computer model can be enhanced in the future are described. User instructions and a FORTRAN listing of the program are included.

  5. Computer simulation of steady-state performance of air-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Ellison, R D; Creswick, F A

    1978-03-01

    A computer model by which the performance of air-to-air heat pumps can be simulated is described. The intended use of the model is to evaluate analytically the improvements in performance that can be effected by various component improvements. The model is based on a trio of independent simulation programs originated at the Massachusetts Institute of Technology Heat Transfer Laboratory. The three programs have been combined so that user intervention and decision making between major steps of the simulation are unnecessary. The program was further modified by substituting a new compressor model and adding a capillary tube model, both of which are described. Performance predicted by the computer model is shown to be in reasonable agreement with performance data observed in our laboratory. Planned modifications by which the utility of the computer model can be enhanced in the future are described. User instructions and a FORTRAN listing of the program are included.

  6. Field Performance of Inverter-Driven Heat Pumps in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, James [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Aldrich, Robb [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-08-01

    CARB observed a wide range of operating efficiencies and outputs from site to site. Maximum capacities were found to be generally in line with manufacturer's claims as outdoor temperatures fell to -10°F. The reasons for the wide range in heating performance likely include: low indoor air flow rates, poor placement of outdoor units, relatively high return air temperatures, thermostat set back, integration with existing heating systems, and occupants limiting indoor fan speed. Even with lower efficiencies than published in other studies, most of the heat pumps here still provide heat at lower cost than oil, propane, or certainly electric resistance systems.

  7. Performance of Different Experimental Absorber Designs in Absorption Heat Pump Cycle Technologies: A Review

    Directory of Open Access Journals (Sweden)

    Jonathan Ibarra-Bahena

    2014-02-01

    Full Text Available The absorber is a major component of absorption cycle systems, and its performance directly impacts the overall size and energy supplies of these devices. Absorption cooling and heating cycles have different absorber design requirements: in absorption cooling systems, the absorber works close to ambient temperature, therefore, the mass transfer is the most important phenomenon in order to reduce the generator size; on the other hand, in heat transformer absorption systems, is important to recover the heat delivered by exothermic reactions produced in the absorber. In this paper a review of the main experimental results of different absorber designs reported in absorption heat pump cycles is presented.

  8. Performance analysis of multi-pump Raman+EDFA hybrid amplifiers for WDM systems

    Science.gov (United States)

    Jardim Martini, Márcia M.; Pontes, Maria José; Ribeiro, Moisés. R. N.; Kalinowski, Hypolito José

    2014-08-01

    An approximated technique to optimize the gain profile of multi-pump broadband hybrid amplifiers (Raman+EDFA) under residual pump recycling is applied to a WDM system. The Optimized hybrid amplifier configurations with multi-pumping were analyzed considering different number of input channels in order to check the global gain saturation and the changes in the global gain profile that occur due to signal-pump, signal-signal, and pump-pump interactions. This work extends the optimization of the gain profile from Raman+EDFA hybrid amplifiers and studies the signal-signal interactions, signal-pumping and pumping-pumping WDM systems. Multiple input channels allowed the gain characterization of the Raman+EDFA hybrid amplifier in terms of global gain, ripple, and noise figure considering applications for WDM systems.

  9. Sensitivity analysis on the performances of a closed-loop Ground Source Heat Pump

    Science.gov (United States)

    Casasso, Alessandro; Sethi, Rajandrea

    2014-05-01

    Ground Source Heat Pumps (GSHP) permit to achieve a significant reduction of greenhouse gas emissions, and the margins for economic saving of this technology are strongly correlated to the long-term sustainability of the exploitation of the heat stored in the soil. The operation of a GSHP over its lifetime should be therefore modelled considering realistic conditions, and a thorough characterization of the physical properties of the soil is essential to avoid large errors of prediction. In this work, a BHE modelling procedure with the finite-element code FEFLOW is presented. Starting from the governing equations of the heat transport in the soil around a GSHP and inside the BHE, the most important parameters are individuated and the adopted program settings are explained. A sensitivity analysis is then carried on both the design parameters of the heat exchanger, in order to understand the margins of improvement of a careful design and installation, and the physical properties of the soil, with the aim of quantifying the uncertainty induced by their variability. The relative importance of each parameter is therefore assessed by comparing the statistical distributions of the fluid temperatures and estimating the energy consumption of the heat pump, and practical conclusions are from these results about the site characterization, the design and the installation of a BHE. References Casasso A., Sethi R., 2014 Efficiency of closed loop geothermal heat pumps: A sensitivity analysis, Renewable Energy 62 (2014), pp. 737-746 Chiasson A.C., Rees S.J., Spitler J.D., 2000, A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems, ASHRAE Transactions 106 (2000), pp. 380-393 Delaleux F., Py X., Olives R., Dominguez A., 2012, Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity, Applied Thermal Engineering 33-34, pp. 92-99 Diao N., Li Q., Fang Z., 2004, Heat transfer in

  10. Comparisons of Hydraulic Performance in Permanent Maglev Pump for Water-Jet Propulsion

    Directory of Open Access Journals (Sweden)

    Puyu Cao

    2014-08-01

    Full Text Available The operation of water-jet propulsion can generate nonuniform inflow that may be detrimental to the performance of the water-jets. To reduce disadvantages of the nonuniform inflow, a rim-driven water-jet propulsion was designed depending on the technology of passive magnetic levitation. Insufficient understanding of large performance deviations between the normal water-jets (shaft and permanent maglev water-jets (shaftless is a major problem in this paper. CFD was directly adopted in the feasibility and superiority of permanent maglev water-jets. Comparison and discussion of the hydraulic performance were carried out. The shaftless duct firstly has a drop in hydraulic losses (K1, since it effectively avoids the formation and evolution of the instability secondary vortex by the normalized helicity analysis. Then, the shaftless intake duct improves the inflow field of the water-jet pump, with consequencing the drop in the backflow and blocking on the blade shroud. So that the shaftless water-jet pump delivers higher flow rate and head to the propulsion than the shaft. Eventually, not only can the shaftless model increase the thrust and efficiency, but it has the ability to extend the working range and broaden the high efficiency region as well.

  11. CFD and comparisons for a pump as turbine: Mesh reliability and performance concerns

    Directory of Open Access Journals (Sweden)

    O. Fecarotta, A. Carravetta1 , H. M. Ramos

    2011-01-01

    Full Text Available The need for saving energy in water supply systems has become one of the main concerns of system managers and it will become more important in a near future. New strategies must be developed and implemented in the major energy consumption systems like those for water supply. In drinking pipe systems the use of Pressure Reducing Valves (PRV as a dissipative device is the common way to uniform the pressure control through a localised head loss. The use of micro-turbines or pumps operating as turbines seem to be an alternative technical and environmental available solution to either control the pressure as well as to produce energy. Pumps as turbines (PAT could be a convenient choice, but a deep study of the machine in different operating conditions is necessary in order to prevent the water system from ruptures. This paper shows that semi-empirical parametrical models do not generally predict with precision the behaviour of a pump operating as a turbine, while CFD analysis could be a reliable tool to better understand the interaction between the hydromechanical equipment and the flow behaviour. Nevertheless the CFD calculation difficulty is generally very high and the minimum complexity of the CFD calculation mesh has been investigated, in order to perform faster and reliable simulations. Thus CFD calculations have been carried out to predict the turbine behaviour under different flow conditions and the performance curves have been obtained. Some calculations in unsteady state flow regimes have been led to investigate the response of the machine to a sudden discharge changing, as a preliminary study of the behaviour of a turbomachine installed in a water distribution system under water hammer situations.

  12. Who can monitor the court interpreter's performance?

    DEFF Research Database (Denmark)

    Martinsen, Bodil

    2009-01-01

    to assume that they are able to monitor and thus evaluate the interpreting if the foreign language used in court belongs to the major ones within the Danish educational system, like English or French, contrary to "exotic" migrant languages. This paper highlights the problem that the interpreted proceedings...... are far less transparent for the legal participants than they normally assume. This problem, in turn, stresses the importance of a) the interpreter's competence and self-awareness and b) the use of check interpreters.  ...

  13. 99Tc Process Monitoring System In-Lab Performance Characterization

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, Matthew J.; Niver, Cynthia M.

    2014-01-01

    Executive Summary A 99Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The new system’s design has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant. A portion of the new 200W P&T Plant is dedicated to removal of 99Tc from contaminated groundwater in the 200 West Area. 99Tc, as the pertechnetate anion (99TcO4-), is remediated through delivery of water into two trains (Trains A and B) of three tandem extraction columns filled with Purolite A530E resin. The resin columns cannot be regenerated; therefore, once they have reached their maximum useful capacity, the columns must be disposed of as radioactive waste. The Tc-Mon system’s primary duty will be to periodically sample and analyze the effluents from each of the two primary extraction columns to determine 99Tc breakthrough. The Tc-Mon system will enable the CH2M Hill Plateau Remediation Company (CHPRC) to measure primary extraction column breakthrough on demand. In this manner, CHPRC will be able to utilize each extraction column to its maximum capacity. This will significantly reduce column disposal and replacement costs over the life of the plant. The Tc-Mon system was constructed by Burge Environmental, Inc. and was delivered to PNNL in June 2013 for setup and initial hardware and software performance testing in the 325 Building. By early July, PNNL had initiated an in-laboratory performance characterization study on the system. The objective was to fully calibrate the system and then evaluate the quality of the analytical outputs 1) against a series of clean

  14. Results of heating mode performance tests of a solar-assisted heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.B.; Smetana, F.O.

    1979-04-01

    The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

  15. Effects of volute geometry and impeller orbit on the hydraulic performance of a centrifugal pump

    Science.gov (United States)

    Flack, R. D.; Lanes, R. F.

    1983-01-01

    Overall performance data was taken for a Plexiglas water pump with a logarithmic spiral volute and rectangular cross sectioned flow channels. Parametric studies were made in which the center of the impeller was offset from the design center of the volute. The rig was also designed such that the impeller was allowed to synchronously orbit by a fixed amount about any center. The studies indicate that decreasing the tongue clearance decreases the head at low flowrates and increases the head at high flowrates. Also, decreasing the volute area in the first half of the volute and holding the tongue clearance the same, resulted in a decreased head for low flowrates but performance at high flowrates was not affected. Finally, the overall hydraulic performance was not affected by the impeller orbitting about the volute center.

  16. Experimental performance evaluation of heat pump by using CO2 as a refrigerant

    Science.gov (United States)

    Venkatesh, V. K.; Basavaraju, M. G.; Sreenivas Rao, K. V.

    2016-09-01

    In this experiment the refrigerant used is CO2 which is naturally available, eco friendly, economical, non toxic, non flammable and non corrosive. Its Ozone Depletion Potential (ODP) is zero and minimum Global Warming Potential (GWP). The performance evaluation of prototype vapor compression heat pump model was performed and evaluated the different parameters like COP (Co-efficient of performance), LMTD (Logarithmic mean temperature difference) and outlet water temperature of condenser. The experiment is carried out for two different condensers by varying mass flow rate and pressure. The water in the shell side was heated by absorbing heat from refrigerants in the tube side of condensers by counter flow heat exchanging method. The experimental result indicates fairly good COP with the use of CO2 refrigerant. These advantages of CO2 as a refrigerant favors the replacement for globally used refrigerant with CO2.

  17. Results of heating mode performance tests of a solar-assisted heat pump

    Science.gov (United States)

    Jones, C. B.; Smetana, F. O.

    1979-01-01

    The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

  18. Performance of the CMS Beam Halo Monitor

    CERN Document Server

    CMS Collaboration

    2015-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of radiation hard synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes for a direction sensitive measurement. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and received data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed i...

  19. User's manual for heat-pump seasonal-performance model (SPM) with selected parametric examples

    Energy Technology Data Exchange (ETDEWEB)

    1982-06-30

    The Seasonal Performance Model (SPM) was developed to provide an accurate source of seasonal energy consumption and cost predictions for the evaluation of heat pump design options. The program uses steady state heat pump performance data obtained from manufacturers' or Computer Simulation Model runs. The SPM was originally developed in two forms - a cooling model for central air conditioners and heat pumps and a heating model for heat pumps. The original models have undergone many modifications, which are described, to improve the accuracy of predictions and to increase flexibility for use in parametric evaluations. Insights are provided into the theory and construction of the major options, and into the use of the available options and output variables. Specific investigations provide examples of the possible applications of the model. (LEW)

  20. Numerical simulation of the influence of distributor pitch diameter on performance and pressure fluctuations in a pump-turbine

    Science.gov (United States)

    Sun, Y. K.; Zuo, Z. G.; Liu, S. H.; Wu, Y. L.; Liu, J. T.

    2012-11-01

    In order to analyse the influence of distributor pitch diameter on performance and pressure fluctuations in a pump turbine, a numerical model based on a pumped storage power station was built to develop the numerical simulation. Steady and unsteady flows were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The performance, inner flow and pressure fluctuations between runner blades and guide vanes of both turbine and pump mode was contrasted in different distributor pitch diameters. The result shows there was a maximum total efficiency in a given distributor pitch diameter instead of the design diameter. Amplitudes and frequencies of pressure fluctuations on this diameter and design diameter were analysed, minor differences were observed. This position can be considered to help improving the flow of the pump turbine.

  1. Performance Testing of a Liquid Metal Pump for In-Space Power Systems

    Science.gov (United States)

    Polzin, Kurt

    2011-01-01

    Fission surface power (FSP) systems could be used to provide power on the surface of the moon, Mars, or other planets and moons of our solar system. Fission power systems could provide excellent performance at any location, including those near the poles or other permanently shaded regions, and offer the capability to provide on demand power at any time, even at large distances from the sun. Fission-based systems also offer the potential for outposts, crew and science instruments to operate in a power-rich environment. NASA has been exploring technologies with the goal of reducing the cost and technical risk of employing FSP systems. A reference 40 kWe option has been devised that is cost-competitive with alternatives while providing more power for less mass anywhere on the lunar surface. The reference FSP system is also readily extensible for use on Mars, where it would be capable of operating through global dust storms and providing year-round power at any Martian latitude. Detailed development of the FSP concept and the reference mission are documented in various other reports. The development discussed in this paper prepares the way for testing of the Technology Demonstration Unit (TDU), which is a 10 kWe end-to-end test of FSP technologies intended to raise the entire FSP system to technology readiness level (TRL) 6. The Early Flight Fission Test Facility (EFF-TF) was established by NASA s Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a nonnuclear test methodology. This includes fabrication and testing at both the module/component level and at near prototypic reactor components and configurations allowing for realistic thermal-hydraulic evaluations of systems. The liquid-metal pump associated with the FSP system must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National

  2. Localized thin film damage sourced and monitored via pump-probe modulated thermoreflectance

    Science.gov (United States)

    Donovan, Brian F.; Tomko, John A.; Giri, Ashutosh; Olson, David H.; Braun, Jeffrey L.; Gaskins, John T.; Hopkins, Patrick E.

    2017-05-01

    Damage in the form of dewetting and delamination of thin films is a major concern in applications requiring micro- or nano-fabrication. In non-contact nanoscale characterization, optical interrogation must be kept to energies below damage thresholds in order to conduct measurements such as pump-probe spectroscopy. In this study, we show that the thermoreflectance of thin films can indicate the degree of film damage induced by a modulated optical heating source. By adjusting the absorbed power of the pump heating event, we identify the characteristics of the change in the thermoreflectance signal when leading up to and exceeding the damage threshold of gold films of varying thicknesses on glass substrates.

  3. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y. [Kubota Corp., Osaka (Japan)

    1997-11-25

    When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is lower than that in the water heat source. Better performance was shown than in operating the water heat source independently. 2 refs., 9 figs.

  4. Performance prediction and flow analysis in the vaned distributor of a pump turbine under low flow rate in pump mode

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The main goal of this work is to investigate the possible different flow patterns existing in pump turbine under off-design conditions in pump mode. Numerical simulations by solving the Navier-Stokes equation, coupled with the "SST k-ω" turbulence model, were carried out. Flow characteristics were assumed to be stalled in the appropriate region of ?ow rate levels of Q/QD=0.15–0.61. The simulation result was compared with experimental data and they showed good agreement. Consequently, velocity fields in three axial locations in stay vanes and guide vanes were analysed in details. It was shown that "jet-wake" flow pattern exists near the band, which changes little in the whole shape with flow rate increasing; to the middle location of vanes, reverse flow begins to appear on the interface between the runner and guide vanes, which will disappear gradually as the flow rate increases; massive reverse flow is captured near the crown, whose intensity will be weakened as the flow rate increases. Ultimately, it was found that the special head-flow profile can be ascribed to the special hydraulic loss characteristics of the stay vanes and guide vanes.

  5. Computer monitoring and optimization of the steam boiler performance

    OpenAIRE

    Sobota Tomasz

    2017-01-01

    The paper presents a method for determination of thermo-flow parameters for steam boilers. This method allows to perform the calculations of the boiler furnace chamber and heat flow rates absorbed by superheater stages. These parameters are important for monitoring the performance of the power unit. Knowledge of these parameters allows determining the degree of the furnace chamber slagging. The calculation can be performed in online mode and use to monitoring of steam boiler. The presented me...

  6. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    National Research Council Canada - National Science Library

    Karolis Januševičius; Giedrė Streckienė

    2013-01-01

    .... Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country...

  7. Expected Performance of the GLAST Burst Monitor

    Science.gov (United States)

    Meegan, Charles; Fishman, Gerald; Kouveliotou, Chryssa; Wilson-Hodge, Colleen; Paciesas, William; Preece, Robert; Briggs, Michael; Bhat, Narayana; Connaughton, Valerie; Greiner, Jochen; vonKienlin, Andreas; Diehl, Roland; Steinle, Helmut; Bissaldi, Elisabetta; Kippen, R. Marc

    2007-01-01

    The GLAST Burst Monitor (GBM) will enhance LAT observations of GRBs by extending the spectral coverage from the LAT threshold down to approx. 8 kev, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from selected bursts outside the LAT field of view. GBM consists of twelve NaI scintillation detectors operating in the 8 kev to 1 MeV energy range and two BGO scintillation detectors operating in the 150 keV to 30 MeV energy range. Detector resolution, effective area, and angular response have been determined by calibrations. Analyses indicate that the on-board burst threshold will be approx. 0.7 photon/cm2/s and the on-board burst localization accuracy will typically be better than 8 degrees.

  8. Improved PSI Performance for Landslide Monitoring Applications

    Science.gov (United States)

    Duro, Javier; Iglesias, Ruben; Blanco, Pablo; Sanchez, Francisco; Albiol, David

    2015-05-01

    The work proposed in this paper shows advanced Persistent Scatter Interferometry (PSI) processing based on the use of the Non-Local Interferometric SAR (NLInSAR) filtering for improving landslides monitoring applications. The rationale is to enhance the interferometric phase quality, preserving the full resolution of SAR images, in order to detect both distributed and deterministic scatterers, with the objective of increasing the density of final PSI products. Moreover, since SAR systems are only sensitive to detect displacements in the line-of-sight (LOS) direction, the importance of projecting PSI displacement products along the steepest gradient of the terrain slope is put forward. Two TerraSAR-X data sets acquired in ascending mode corresponding to the period from April to November 2011, and from August to November 2013, respectively, over the area of El Portalet (Central Spanish Pyrenees), are employed for this purpose.

  9. ATLAS Offline Software Performance Monitoring and Optimization

    CERN Document Server

    Chauhan, N; Kittelmann, T; Langenberg, R; Mandrysch , R; Salzburger, A; Seuster, R; Ritsch, E; Stewart, G; van Eldik, N; Vitillo, R

    2014-01-01

    In a complex multi-developer, multi-package software environment, such as the ATLAS offline Athena framework, tracking the performance of the code can be a non-trivial task in itself. In this paper we describe improvements in the instrumentation of ATLAS offline software that have given considerable insight into the performance of the code and helped to guide optimisation. Code can be instrumented firstly using the PAPI tool, which is a programing interface for accessing hardware performance counters. PAPI events can count floating point operations, cycles and instructions and cache accesses. Triggering PAPI to start/stop counting for each algorithm and processed event gives a good understanding of the whole algorithm level performance of ATLAS code. Further data can be obtained using pin, a dynamic binary instrumentation tool. Pintools can be used to obtain similar statistics as PAPI, but advantageously without requiring recompilation of the code. Fine grained routine and instruction level instrumentation is...

  10. ATLAS Offline Software Performance Monitoring and Optimization

    CERN Document Server

    Chauhan, N; The ATLAS collaboration; Kittelmann, T; Langenberg, R; Mandrysch , R; Salzburger, A; Seuster, R; Ritsch, E; Stewart, G; van Eldik, N; Vitillo, R

    2013-01-01

    In a complex multi-developer, multi-package software environment, such as the ATLAS offline Athena framework, tracking the performance of the code can be a non-trivial task in itself. In this paper we describe improvements in the instrumentation of ATLAS offline software that have given considerable insight into the performance of the code and helped to guide optimisation. Code can be instrumented firstly using the PAPI tool, which is a programing interface for accessing hardware performance counters. PAPI events can count floating point operations, cycles and instructions and cache accesses. Triggering PAPI to start/stop counting for each algorithm and processed event gives a good understanding of the whole algorithm level performance of ATLAS code. Further data can be obtained using pin, a dynamic binary instrumentation tool. Pintools can be used to obtain similar statistics as PAPI, but advantageously without requiring recompilation of the code. Fine grained routine and instruction level instrumentation is...

  11. Performance of Network and Service Monitoring Frameworks

    CERN Document Server

    Lahmadi, Abdelkader; Festor, Olivier

    2009-01-01

    The efficiency and the performance of anagement systems is becoming a hot research topic within the networks and services management community. This concern is due to the new challenges of large scale managed systems, where the management plane is integrated within the functional plane and where management activities have to carry accurate and up-to-date information. We defined a set of primary and secondary metrics to measure the performance of a management approach. Secondary metrics are derived from the primary ones and quantifies mainly the efficiency, the scalability and the impact of management activities. To validate our proposals, we have designed and developed a benchmarking platform dedicated to the measurement of the performance of a JMX manager-agent based management system. The second part of our work deals with the collection of measurement data sets from our JMX benchmarking platform. We mainly studied the effect of both load and the number of agents on the scalability, the impact of management...

  12. 3D Blade Hydraulic Design Method of the Rotodynamic Multiphase Pump Impeller and Performance Research

    Directory of Open Access Journals (Sweden)

    Yongxue Zhang

    2014-02-01

    Full Text Available A hydraulic design method of three-dimensional blade was presented to design the blades of the rotodynamic multiphase pump. Numerical simulations and bench test were conducted to investigate the performance of the example impeller designed by the presented method. The results obtained from the bench test were in good agreement with the simulation results, which indicated the reasonability of the simulation. The distributions of pressure and gas volume fraction were analyzed and the results showed that the designed impeller was good for the transportation of mixture composed of gas and liquid. In addition, the advantage of the impeller designed by the presented method was suitable for using in large volume rate conditions, which were reflected by the comparison of the head performance between this three-dimensional design method and another one.

  13. Decoupled CFD-based optimization of efficiency and cavitation performance of a double-suction pump

    Science.gov (United States)

    Škerlavaj, A.; Morgut, M.; Jošt, D.; Nobile, E.

    2017-04-01

    In this study the impeller geometry of a double-suction pump ensuring the best performances in terms of hydraulic efficiency and reluctance of cavitation is determined using an optimization strategy, which was driven by means of the modeFRONTIER optimization platform. The different impeller shapes (designs) are modified according to the optimization parameters and tested with a computational fluid dynamics (CFD) software, namely ANSYS CFX. The simulations are performed using a decoupled approach, where only the impeller domain region is numerically investigated for computational convenience. The flow losses in the volute are estimated on the base of the velocity distribution at the impeller outlet. The best designs are then validated considering the computationally more expensive full geometry CFD model. The overall results show that the proposed approach is suitable for quick impeller shape optimization.

  14. Influence of Valve's Characteristic on Total Performance of Three Cylinders Internal Combustion Water Pump

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hongxin; ZHANG Tiezhu; WANG Weichao

    2009-01-01

    lntenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of valve's characteristic on ICP's total performance will found the base for its optimum design. Based on the theoretical and testing fruits of single cylinder prototype, the performance of the valves and complete appliance of the latest is simulated. When the natural frequency of valves is approximately to the round number times of the working frequency, volumetric efficiency is seriously low. The nominal rotational speed of the prototype is nearly to the speed where the volumetric efficiency is lowest, which is harmful to the normal work of ICP, so further structure optimization of valves should be carried out. The change of volumetric efficiency has great influence on the fuel consumption rate,output flow, effective thermal efficiency, effective power, and so on, but little on output pressure.

  15. Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2012

    Energy Technology Data Exchange (ETDEWEB)

    T. E. Wierman

    2013-10-01

    This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). The TDP failure modes considered are failure to start, failure to run less than or equal to 1 hour, failure to run more than 1 hour, and (for normally running systems) failure to run. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant increasing trends were identified in the TDP results. Statistically significant decreasing trends were identified for TDP run hours per reactor critical year and start demands.

  16. 36 CFR 1210.51 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Monitoring and reporting program performance. 1210.51 Section 1210.51 Parks, Forests, and Public Property NATIONAL ARCHIVES AND... managing and monitoring each project, program, subaward, function or activity supported by the...

  17. Exergy performance analysis of the conceptual district energy network system with heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seung Won; Chung, Ha Seung [Hongik University, Seoul (Korea, Republic of); Kim, Min Sung [Korea Institute of Energy Research, Daejeon (Korea, Republic of)

    2014-08-15

    To increase the efficiency of a district heating system, we propose a district energy network concept which combines several heating resources with additional electric heat pump and thermal energy storage. With help of thermal energy storage, a heat pump can be operated at maximum efficiency at all the time. Electricity generated with less CO{sub 2} emission makes the proposed system much more environmentally friendly. Even though the proposed concept can be applied to any given situation, a specific target area was chosen to show the effectiveness of the newly proposed energy network concept more clearly. Several constraints were applied for the selection process and a simplified model used for quantitative comparison between the existing and the developed concept. Exergy analysis showed the increased performance of proposed energy network system. The result showed that the newly proposed concept generates less CO{sub 2} emission by 46% at maximum compared to the existing system. By using additional renewable energy sources, we can reduce CO{sub 2} emission even further.

  18. Energy Performance and Economic Evaluation of Heat Pump/Organic Rankine Cycle System with Sensible Thermal Storage

    DEFF Research Database (Denmark)

    Carmo, C.; Dumont, O.; Nielsen, M. P.

    2016-01-01

    that consists of a ground-source heat pump with possibility of reversing operation as an ORC power cycle combined with solar heating in a single-family building is introduced. The ORC mode enables the use of solar energy in periods of no heat energy demand and reverses the heat pump cycle to supply electrical......The interaction between electrical and thermal energy demands represent a potential area for balancing supply and demand that could contribute to the integration of intermittent renewables in energy systems. To enable the interaction between thermal and electric energy, an innovative concept...... power.This paper combines a dynamic model based on empirical data of the HP/ORC system with lessons learned from 140 heat pump installations operating in real-life conditions in a cold climate. These installations were monitored for a period up to 5 years.Based on the aforementioned model and real...

  19. Energy performance and economic evaluation of heat pump/organic rankine cycle system with sensible thermal storage

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2016-01-01

    that consists of a ground-source heat pump with possibility of reversing operation as an ORC power cycle combined with solar heating in a single-family building is introduced. The ORC mode enables the use of solar energy in periods of no heat energy demand and reverses the heat pump cycle to supply electrical......The interaction between electrical and thermal energy demands represent a potential area for balancing supply and demand that could contribute to the integration of intermittent renewables in energy systems. To enable the interaction between thermal and electric energy, an innovative concept...... power. This paper combines a dynamic model based on empirical data of the HP/ORC system with lessons learned from 140 heat pump installations operating in real-life conditions in a cold climate. These installations were monitored for a period up to 5 years. Based on the aforementioned model and real...

  20. Safety KPIs - Monitoring of safety performance

    Directory of Open Access Journals (Sweden)

    Andrej Lališ

    2014-09-01

    Full Text Available This paper aims to provide brief overview of aviation safety development focusing on modern trends represented by implementation of Safety Key Performance Indicators. Even though aviation is perceived as safe means of transport, it is still struggling with its complexity given by long-term growth and robustness which it has reached today. Thus nowadays safety issues are much more complex and harder to handle than ever before. We are more and more concerned about organizational factors and control mechanisms which have potential to further increase level of aviation safety. Within this paper we will not only introduce the concept of Key Performance Indicators in area of aviation safety as an efficient control mechanism, but also analyse available legislation and documentation. Finally we will propose complex set of indicators which could be applied to Czech Air Navigation Service Provider.

  1. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  2. The measured field performances of eight different mechanical and air-lift water-pumping wind-turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kentfield, J.A.C. [Univ. of Calgary, Alberta (Canada)

    1996-12-31

    Results are presented of the specific performances of eight, different, water-pumping wind-turbines subjected to impartial tests at the Alberta Renewable Energy Test Site (ARETS), Alberta, Canada. The results presented which were derived from the test data, obtained independently of the equipment manufacturers, are expressed per unit of rotor projected area to eliminate the influence of machine size. Hub-height wind speeds and water flow rates for a common lift of 5.5 m (18 ft) constitute the essential test data. A general finding was that, to a first approximation, there were no major differences in specific performance between four units equipped with conventional reciprocating pumps two of which employed reduction gearing and two of which did not. It was found that a unit equipped with a Moyno pump performed well but three air-lift machines had, as was expected, poorer specific performances than the more conventional equipment. 10 refs., 9 figs.

  3. A Performance Prediction Method for Pumps as Turbines (PAT Using a Computational Fluid Dynamics (CFD Modeling Approach

    Directory of Open Access Journals (Sweden)

    Emma Frosina

    2017-01-01

    Full Text Available Small and micro hydropower systems represent an attractive solution for generating electricity at low cost and with low environmental impact. The pump-as-turbine (PAT approach has promise in this application due to its low purchase and maintenance costs. In this paper, a new method to predict the inverse characteristic of industrial centrifugal pumps is presented. This method is based on results of simulations performed with commercial three-dimensional Computational Fluid Dynamics (CFD software. Model results have been first validated in pumping mode using data supplied by pump manufacturers. Then, the results have been compared to experimental data for a pump running in reverse. Experimentation has been performed on a dedicated test bench installed in the Department of Civil Construction and Environmental Engineering of the University of Naples Federico II. Three different pumps, with different specific speeds, have been analyzed. Using the model results, the inverse characteristic and the best efficiency point have been evaluated. Finally, results have been compared to prediction methods available in the literature.

  4. A study on modeling and performance assessment of a heat pump system for utilizing low temperature geothermal resources in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hepbasli, Arif [Department of Mechanical Engineering, Faculty of Engineering, Ege University, 35100 Bornova, Izmir (Turkey); Tolga Balta, M. [Department of Mechanical Engineering, Aksaray Engineering Faculty, Nigde University, 68100 Aksaray (Turkey)

    2007-10-15

    Low and moderate geothermal resources are found in most areas of the world. A very efficient way to heat and air-condition homes and buildings is the utilization of ground source heat pumps (GSHPs), also known as geothermal heat pump (GHPs), to obtain heat energy from low temperature geothermal resources. The present study deals with the modeling and performance evaluation of a heat pump system utilizing a low temperature geothermal resource, which is approximated to a geothermal reservoir. The system was designed, constructed and tested in Nigde University, Nigde, Turkey and has been successfully operated since 2005. Energy and exergy analysis methods were used to assess the system performance based on the experimental data. Exergy destructions (or irreversibilities) as well as energy and exergy efficiency relations were presented for each component of the heat pump unit and the whole system, while some thermodynamic parameters, such as fuel depletion ratio, relative irreversibility, productivity lack, exergetic factor and improvement potential, were investigated for the system. Energy and exergy efficiency values on a product/fuel basis were found to range from 73.9% to 73.3% and 63.3% to 51.7% at dead (reference) state temperatures varying from 0 to 25 C for the heat pump unit and entire system, respectively. It is expected that the model presented here would be beneficial to the researchers, government administration, and engineers working in the area of heat pump systems for residential applications. (author)

  5. Metacognitive monitoring and strategic behaviour in working memory performance.

    Science.gov (United States)

    Touron, Dayna R; Oransky, Natalie; Meier, Matthew E; Hines, Jarrod C

    2010-08-01

    Research indicates that cognitive age differences can be influenced by metacognitive factors. This research has generally focused on simple memory tasks. Age differences in working memory (WM) performance are pronounced, but are typically attributed to basic cognitive deficits rather than metacognitive factors. However, WM performance can be influenced by strategic behaviour that might be driven by metacognitive monitoring. In the current project, we attempted to connect these lines of research by examining age differences in metacognitive WM monitoring and strategies. In Experiment 1, younger and older adult participants completed a computerized operation span task in conditions that either required or did not require monitoring reports. Participants in the monitoring condition predicted and postdicted global performance for each block and rated their responses following each trial within a block. In Experiment 2, participants also reported their trial-level strategic approach. In contrast to the age equivalence typically found for simple memory monitoring, results demonstrated age differences in WM monitoring accuracy. Overall age differences in strategy use were not found, but using effective strategies benefited older adults' performance more than younger adults'. Furthermore, age-related differences in the WM task appear to be mediated by the accuracy of performance monitoring.

  6. Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source

    Directory of Open Access Journals (Sweden)

    Ali Kahraman

    2009-08-01

    Full Text Available In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 °C, 30 °C and 40 °C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 °C. For the heat source temperatures of 20 °C, 30 °C and 40 °C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about ±2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system.

  7. TAUOVERSUPERMON: LOW-OVERHEAD ONLINE PARALLEL PERFORMANCE MONITORING

    Energy Technology Data Exchange (ETDEWEB)

    SOTTILE, MATTHEW JOSEPH [Los Alamos National Laboratory; NATARAJ, AROON [Los Alamos National Laboratory; MALONY, ALLEN [Los Alamos National Laboratory; MORRIS, ALAN [Los Alamos National Laboratory; SHENDE, SAMEER [Los Alamos National Laboratory

    2007-01-30

    Online or Real-time application performance monitoring allows tracking performance characteristics during execution as opposed to doing so post-mortem. This opens up several possibilities otherwise unavailable such as real-time visualization and application performance steering that can be useful in the context of long-running applications. Two fundamental components that constitute such a performance monitor are the measurement and transport systems. The former captures performance metrics of individual contexts (processes, threads). The latter enables querying the parallel/distributed state from the different contexts and also allows measurement control. As HPC systems grow in size and complexity, the key challenge is to keep the online performance monitor scalable and low overhead while still providing a useful performance reporting capability. We adapt and combine two existing, mature systems - Tuning and Analysis Utility (TAU) and Supermon - to address this problem. Tau performs the measurement while Supermon is used to collect the distributed measurement state. Our experiments show that this novel approach of using a cluster-monitor, Supermon, as the transport for online performance data from Tau leads to very low-overhead application monitoring as well as other beneits unavailable from using a traditional transport such as NFS.

  8. Optical Performance Monitoring using Proactive Monitoring and the Time Caliper Method

    Science.gov (United States)

    Luk, Hon Tung

    The widespread real time multimedia applications generate increasing demands of data transmission capacity nowadays. Fiber-optic communication is the core technology to meet the capacity requirements of the fast growing internet data and to support the long haul transmission with low cost. Reliability is a key issue for high data rate transmission systems because the interruption of connection may result in substantial amount of data lost. Performance monitoring is essential for maintaining reliability by keeping track of the network status rapidly. In this thesis, we will investigate two aspects of performance monitoring in optical communication systems: network-based monitoring and link-based physical layer monitoring. In the case of network-based monitoring, proactive monitoring is used to reduce the acquisition time to obtain the monitoring information. The monitoring process is modeled as a Markov Decision Process. We propose nine different monitoring schemes and show that the scheme with increasing probing number and probing unpopular edge first has the best overall performance, regarding to coverage of monitoring links and blocking probability. On the other hand, if we would like to reduce the cost for proactive monitoring, the shortest path probing scheme is the optimal monitoring schemes when the monitoring paths are probed independently. In addition, if we consider the cases of edge overlapping and node overlapping of the monitoring paths, the overlapping probing scheme may require less number of hops during the monitoring process. Formulas have been derived for checking the conditions when the overlapping probing scheme can be applied. Simulations are performed under different optical network topologies and conditions to evaluate the performance of the schemes. Measurement of relative delay facilitates various monitoring and compensation applications, such as synchronization of subchannels in multiplexing systems, dispersion measurement. In the case of

  9. Technology Solutions Case Study: Field Performance of Inverter-Driven Heat Pumps in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    J. Williamson and R. Aldrich

    2015-09-01

    To better understand and characterize heating performance, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven ASHPs across the northeast United States during the winter of 2013–2014.

  10. Efficiency by means of intelligence. Control engineering increases the performance of pumping and shredders; Effizienz durch Intelligenz. Steuerungstechnik steigert die Leistung von Pump- und Zerkleinerungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Wenner, Carsten; Vogelsang, Hugo [Maschinenbau GmbH, Essen (Germany)

    2009-01-15

    For a long time, modern machine tools are no more applicable efficiently without electronics. However, it is expected frequently from macerators and displacement pumps that they work completely without appropriate control engineering and/or with minimal control engineering. The achievement and efficiency of these systems can be improved by the investment into modern and intelligent control engineering clearly. Under this aspect, the author of the contribution under consideration reports on the application of the macerator RotaCut 5000 in the biogas plant Duderstadt. The protection from foreign bodies and for simultaneous substrate preparation, a RotaCut 5000 is connected before the rotary pump. For both devices, an appropriate performance control unit was installed. Rotary pump and RotaCut 5000 work reliably, efficiently and attain a power demand of 10 kW. This means a saving of 1,600 kW/h per week and a saving between 10,000 and 12,000 euros per year. The entire investment amortized after some months.

  11. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  12. Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; QU Hang; LI Xinguo

    2007-01-01

    An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior.Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hotwater production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.

  13. Study on Operating Performance of Stirling Engine-Driven Vapor Compression Heat Pump System

    Science.gov (United States)

    Kagawa, Noboru

    Stirling engines have many unique advantages including higher thermal efficiencies, preferable exhaust gas characteristics, multi-fuel usage, and low noise and vibration. On the other hand, heat pump systems are very attractive for space heating and cooling, and industrial usage. There are several environmental merits of Stirling driven vapor compression (SDVC) systems. A design method for the SDVC, which is based on mathematical methods for Stirling and Ranking cycles, has been developed. The attractive SDVC performance using conventional and alternative refrigerants was shown. From the calculated Total Equivalent Warming Impact (TEWI) and operating costs, it became clear that the SDVC system with the alternative refrigerant has a higher potential as the future air-conditioning system.

  14. Low-cost, high-performance nonevaporable getter pumps using nonevaporable getter pills

    Energy Technology Data Exchange (ETDEWEB)

    Kodama, Hiraku; Ohno, Shinya; Tanaka, Masatoshi [Faculty of Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501 (Japan); Tanaka, Masato; Okudaira, Koji K. [Faculty of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku 263-8522 (Japan); Mase, Kazuhiko, E-mail: mase@post.kek.jp; Kikuchi, Takashi [Institute of Materials Structure Science, KEK, 1-1 Oho, Tsukuba 305-0801 (Japan)

    2016-09-15

    Nonevaporable getter (NEG) pumps are widely used for maintaining a clean ultrahigh vacuum (UHV) of ≤10{sup −8 }Pa because of their high pumping speeds for hydrogen (H{sub 2}) and active gases in the UHV region. In addition, they are oil free, evaporation free, sputtering free, sublimation free, magnetic field free, vibration free, economical, compact, lightweight, and energy saving. In the present paper, the authors report a new NEG pump which is composed of commercial 60 NEG pills (ϕ10 × 3 mm; 70 wt. % Zr, 24.6 wt. % V, and 5.4 wt. % Fe), titanium parts, a DN 40 conflat flange, and a tantalum heater. The NEG pills are vertically and radially aligned around the heater to maximize the effective area for pumping. After activation at 400 °C for 30 min, the pumping speeds of the NEG pump were measured with the orifice method. Pumping speeds of 140–130, 200–140, 190–130, and 35–17 l/s were estimated for H{sub 2}, CO, CO{sub 2}, and N{sub 2} gasses, respectively, in a pumped-quantity range of 0.01–0.1 Pa l. Since the NEG pump is composed of a heating unit and a NEG module, the pumping speeds can be improved by increasing the number of NEG modules. These NEG pumps are favorable alternatives to sputtering ion pumps or titanium sublimation pumps.

  15. Modern Techniques and Technologies Applied to Training and Performance Monitoring.

    Science.gov (United States)

    Sands, William A; Kavanaugh, Ashley A; Murray, Steven R; McNeal, Jeni R; Jemni, Monèm

    2016-12-05

    Athlete preparation and performance continues to increase in complexity and costs. Modern coaches are shifting from reliance on personal memory, experience, and opinion to evidence from collected training load data. Training load monitoring may hold vital information for developing systems of monitoring that follow the training process with such precision that both performance prediction and day-to-day management of training become an adjunct to preparation and performance. Time series data collection and analyses in sport are still in their infancy with considerable efforts being applied in "big-data" analytics and models of the appropriate variables to monitor and methods for doing so. Training monitoring has already garnered important applications, but lacks a theoretical framework from which to develop further. As such, we propose a framework involving the following: analyses of individuals, trend analyses, rules-based analysis, and statistical process control.

  16. Numerical simulation on the performance of the vortex pump for transporting solid-liquid two-phase with light particles

    Science.gov (United States)

    Mao, W. Y.; Song, P. Y.; Deng, Q. G.; Xu, H. J.

    2016-05-01

    With the purpose of studying performance of the vortex pump for transporting solid-liquid two-phase with light particles whose relative density smaller than 1, the numerical simulation of solid-liquid two phase flowing in the whole channel of a vortex pump with the particle diameter being 0.5 mm, 1 mm, 2 mm, 3 mm and the initial solid phase volume concentrations being 10%, 20% and 30% are respectively carried out by using the commercial software ANSYS Fluent by adopting RNG κ-ɛ turbulent flow model, Eulerian-Eulerian multi-phase flow model and SIMPLEC algorithm. The simulation results show that in the impeller region, the particles concentrate on the non-working surface of the blades, and the particles are rare on the working surface of the blades. As the initial solid phase volume concentration and particle diameter increase, the pump delivery head of vortex pump decrease. The pump delivery head of vortex pump with different initial solid phase concentrations and different particle diameters are predicted and compared with those obtained by an empirical formula, and they shows good agreement.

  17. On the coupled system performance of transcritical CO2 heat pump and rankine cycle

    Science.gov (United States)

    Wang, Hongli; Tian, Jingrui; Hou, Xiujuan

    2013-12-01

    As one of the natural refrigerants, CO2 is a potential substitute for synthesized refrigerants with favorable environmental properties. In order to improve the performance of rankine cycle (RankC), the coupled system cycle (CSC) was designed and the performance was analyzed in this paper, which the CSC is combined by the RankC and the transcritical CO2 heat pump cycle with an expander. Based on thermodynamic principles, the performance analysis platform was designed and the performance analysis was employed. The results show that the average efficiency of the RankC is about 30 %, and the extraction cycle is about 32 %, while the CSC is about 39 %, and the last one is better than the others at the same parameters. With increasing of the boiler feed water temperature, the efficiencies of the three kinds of cycles show increasing trend. With increasing of pressure in conderser-evaporator or outlet temperature of gas cooler, the efficiency of the CSC shows a downward trend. Some fundamental data were obtained for increasing the RankC efficiency by waste heat recovery, and play an active role in improvement the efficiency of power plants.

  18. Performance Health Monitoring of Large-Scale Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamony, Ram [IBM Research, Austin, TX (United States)

    2014-11-20

    This report details the progress made on the ASCR funded project Performance Health Monitoring for Large Scale Systems. A large-­scale application may not achieve its full performance potential due to degraded performance of even a single subsystem. Detecting performance faults, isolating them, and taking remedial action is critical for the scale of systems on the horizon. PHM aims to develop techniques and tools that can be used to identify and mitigate such performance problems. We accomplish this through two main aspects. The PHM framework encompasses diagnostics, system monitoring, fault isolation, and performance evaluation capabilities that indicates when a performance fault has been detected, either due to an anomaly present in the system itself or due to contention for shared resources between concurrently executing jobs. Software components called the PHM Control system then build upon the capabilities provided by the PHM framework to mitigate degradation caused by performance problems.

  19. Robust modeling and performance analysis of high-power diode side-pumped solid-state laser systems.

    Science.gov (United States)

    Kashef, Tamer; Ghoniemy, Samy; Mokhtar, Ayman

    2015-12-20

    In this paper, we present an enhanced high-power extrinsic diode side-pumped solid-state laser (DPSSL) model to accurately predict the dynamic operations and pump distribution under different practical conditions. We introduce a new implementation technique for the proposed model that provides a compelling incentive for the performance assessment and enhancement of high-power diode side-pumped Nd:YAG lasers using cooperative agents and by relying on the MATLAB, GLAD, and Zemax ray tracing software packages. A large-signal laser model that includes thermal effects and a modified laser gain formulation and incorporates the geometrical pump distribution for three radially arranged arrays of laser diodes is presented. The design of a customized prototype diode side-pumped high-power laser head fabricated for the purpose of testing is discussed. A detailed comparative experimental and simulation study of the dynamic operation and the beam characteristics that are used to verify the accuracy of the proposed model for analyzing the performance of high-power DPSSLs under different conditions are discussed. The simulated and measured results of power, pump distribution, beam shape, and slope efficiency are shown under different conditions and for a specific case, where the targeted output power is 140 W, while the input pumping power is 400 W. The 95% output coupler reflectivity showed good agreement with the slope efficiency, which is approximately 35%; this assures the robustness of the proposed model to accurately predict the design parameters of practical, high-power DPSSLs.

  20. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  1. Performance evaluation of quality monitor models in spot welding

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhongdian; Li Dongqing; Wang Kai

    2005-01-01

    Performance of quality monitor models in spot welding determines the monitor precision directly, so it's crucial to evaluate it. Previously, mean square error ( MSE ) is often used to evaluate performances of models, but it can only show the total errors of finite specimens of models, and cannot show whether the quality information inferred from models are accurate and reliable enough or not. For this reason, by means of measure error theory, a new way to evaluate the performances of models according to the error distributions is developed as follows: Only if correct and precise enough the error distribution of model is, the quality information inferred from model is accurate and reliable.

  2. Hydraulic performance improvement of the bidirectional pit pump installation based on CFD

    Science.gov (United States)

    Chen, H. X.; Zhou, D. Q.

    2013-12-01

    At present, the efficiency of bidirectional pit pump installation with lift under 2m is still low because of lack of research on it in the past. In the paper, the CFD numerical method and experimental test were applied to study flow characteristic of bidirectional pit pump installation under positive and reverse condition. Through changing airfoil type and position of blade and stay vane, the comprehensive performance of improved model were obtained by calculating many different models. The results showed that when improved model is obtained with type A runner with 4 blades that is 0.7D away from pit exit and unsymmetrical guide vane 0.25dh which away from the impeller outlet, and the flow pattern of the improved solution is steady with high efficiency. Compared with the original scheme, the efficiency of positive and reverse design condition reach to 67.23% and 58.32% respectively, which is increased 6% more than original model on the design condition and 5% on the optimum operating condition, and it achieved the purpose of improvement. According to the runner blade angle of the optimization solution, model synthetic characteristic curve was drawn and internal flow field characteristics was analyzed under optimal positive and reverse conditions. The numerical calculation shows that owing to the lack of stay vane to recycle the energy in outlet runner chamber, the water flow regime is not steady enough in the outlet passage, and that is the main reason for lower efficiency at reverse condition than that at positive condition.

  3. Evaluation of the performance in the solar assisted heat pump system; Taiyonetsu riyo heat pump system no seino hyoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Y. [Osaka Institute of Technology, Osaka (Japan)

    1996-10-27

    Performance of a solar heating system with a hydrothermal source heat pump was evaluated and compared with that of a direct solar heating system. The sun-dependency rates ({Sigma}D and {Sigma}H)of the direct system and heat pump (HP)-provided system were expressed as a function of the rate ({alpha}) of the auxiliary heat against the collected heat and as a function of the performance coefficient and {alpha}, respectively. When the sun-dependency rates are compared, it is found that the HP-provided system is the more advantageous when {Sigma}H/{Sigma}D>1. The relationship between the {alpha}`s of the two systems was clarified and computation was performed to compare the sun-dependency rates on condition that the two are equal in the heat collecting area. Although the sun-dependence rate cannot be elevated to 100% in the HP-provided system, it achieves a sun-dependency rate higher than that of the direct system even when the heat collecting area is small. In cases where the building is economically limited, for instance, with respect to the area for solar collector installation, it is advantageous to employ the HP-provided system. 5 figs., 1 tab.

  4. 38 CFR 43.40 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Monitoring and reporting program performance. 43.40 Section 43.40 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... Status Report. (1) Grantees shall submit annual performance reports unless the awarding agency...

  5. Lessons learned from a pilot RCT of simultaneous versus delayed initiation of continuous glucose monitoring in children and adolescents with type 1 diabetes starting insulin pump therapy.

    Science.gov (United States)

    Olivier, Patricia; Lawson, Margaret L; Huot, Celine; Richardson, Christine; Nakhla, Meranda; Romain, Judette

    2014-05-01

    Uncertainty remains about effectiveness of continuous glucose monitoring (CGM) in pediatric type 1 diabetes (T1D). Success with CGM is related to CGM adherence, which may relate to readiness to make the behavior changes required for effective use. We hypothesize that readiness for change will be greater at initiation of insulin pump therapy than in established pump users, and that this will predict CGM adherence. Our objective was to evaluate the feasibility of a randomized controlled trial (RCT) in children with established T1D comparing simultaneous pump and CGM initiation to standard pump therapy with delayed CGM initiation. We randomized participants to simultaneous pump and CGM initiation or to standard pump therapy with the option of adding CGM 4 months later. CGM adherence was tracked via web-based download and readiness for change assessed with the SOCRATES questionnaire. Of 41 eligible children, 20 agreed to participate; 15 subjects completed the study (7 males; baseline age 11.8 ± 4.0 years; T1D duration 2.7 ± 2.7 years; mean A1C 8.2 ± 0.8%). Six of 8 simultaneous group subjects used CGM > 60% of the time for 4 months compared to 1 of 7 delayed group subjects (P = .02). Using SOCRATES, we could assign 87-100% of subjects to a single motivation stage at baseline and 4 months. This pilot study demonstrates the feasibility of randomizing pump naïve children and adolescents with established T1D to simultaneous pump and CGM initiation versus standard pump therapy with delayed CGM initiation. Lessons from this pilot study were used to inform development of a full-scale multicenter RCT. © 2014 Diabetes Technology Society.

  6. Statistical process control methods for expert system performance monitoring.

    Science.gov (United States)

    Kahn, M G; Bailey, T C; Steib, S A; Fraser, V J; Dunagan, W C

    1996-01-01

    The literature on the performance evaluation of medical expert system is extensive, yet most of the techniques used in the early stages of system development are inappropriate for deployed expert systems. Because extensive clinical and informatics expertise and resources are required to perform evaluations, efficient yet effective methods of monitoring performance during the long-term maintenance phase of the expert system life cycle must be devised. Statistical process control techniques provide a well-established methodology that can be used to define policies and procedures for continuous, concurrent performance evaluation. Although the field of statistical process control has been developed for monitoring industrial processes, its tools, techniques, and theory are easily transferred to the evaluation of expert systems. Statistical process tools provide convenient visual methods and heuristic guidelines for detecting meaningful changes in expert system performance. The underlying statistical theory provides estimates of the detection capabilities of alternative evaluation strategies. This paper describes a set of statistical process control tools that can be used to monitor the performance of a number of deployed medical expert systems. It describes how p-charts are used in practice to monitor the GermWatcher expert system. The case volume and error rate of GermWatcher are then used to demonstrate how different inspection strategies would perform.

  7. Semi-Automated Ensemble Analysis Methods to Evaluate Performance of Pump-and-Treat Systems

    Science.gov (United States)

    Sorel, D.; Tonkin, M. J.; Wilson, D. A.; Dougherty, D. E.

    2009-12-01

    Interest in the use of complex numerical models to aid environmental data analyses will never wane. Nevertheless, this presentation describes systematic and (semi-)automated data analysis techniques that together enable rigorous evaluation of the performance of groundwater pump-and-treat remedies without relying upon complex models. The suite combines statistical analyses of groundwater contaminant concentration data, including spatial and temporal trends, with sophisticated water-level mapping techniques, to develop both quantitative and visual summaries of remedy performance. The methods comprise: 1) Statistical analyses of intrawell concentration data to identify locations where contaminant concentrations exceed relevant standards, have increased from baseline values, and/or exhibit significant upward or downward trends. These analyses are applied using Henlopen Design’s PAM software that automates three tests of concentration data (Comparison to Standard, Comparison to Baseline Values, and Trend Test (Mann-Kendall-Sen-Theil) and produces XML output suitable for plotting, mapping, or subsequent analyses. 2) Spatial interpolation, using quantile kriging, of calculated upper confidence limits of sampled concentrations to approximate the spatial extent of groundwater contaminated above relevant standards for either individual contaminants (contaminant-specific target zones) or an ensemble of contaminants (composite target zones). 3) Analysis of trends in key metrics describing the location, extents (mass and volume), and migration of contamination have also been developed using the 3D interpolation abilities of CTech’s EVS and MVS software, and Henlopen Design’s PAM software. 4) Using SSP&A’s KT3D_H2O software, mapping of water level data by combining kriging with analytic elements, enabling information on the location and rates of pumping, boundary conditions, and other relevant features to be formally incorporated when estimating the extent of hydraulic

  8. New Whole-House Solutions Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-02-24

    The Woods is a sustainable community built by Habitat for Humanity in 2013. This community comprises 30 homes that are high-performance and energy-efficient. With support from Tacoma Public Utilities and the Bonneville Power Administration, the BA-PIRC team is researching the energy performance of these homes and the ductless heat pumps they employ.

  9. The Performance Test for Reactor Coolant Pump (RCP) adopting Variable Restriction Orifice Type Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.; Bae, B. U.; Cho, Y. J. and others

    2014-05-15

    The design values of the RCPTF are 17.2 MPa, 343 .deg. C, 11.7 m{sup 3}/s, and 13 MW in the maximum pressure, temperature, flow rate, and electrical power, respectively. In the RCPTF, various types of tests can be performed including a hydraulic performance test to acquire a H-Q curve as well seal transient tests, thrust bearing transient test, cost down test, NPSHR verification test, and so on. After a commissioning startup test was successfully perfomed, mechanical structures are improved including a flow stabilizer and variable restriction orifice. Two- branch pipe (Y-branch) was installed to regulate the flow rate in the range of performance tests. In the main pipe, a flow restrictor (RO: Restriction Orifice) for limiting the maximum flow rate was installed. In the branch pipe line, a globe valve and a butterfly valves for regulating the flow rate was located on the each branch line. When the pressure loss of the valve side is smaller than that of the RO side, the flow rate of valve side was increasing and the flow disturbance was occurred in the lower pipe line. Due to flow disturbnace, it is to cause an error when measuring RCP head and flow measurement of the venturi flow meter installed in the lower main pipe line, and thus leading to a decrease in measurement accuracy as a result. To increase the efficiency of the flow control availability of the test facility, the variable restriction orifice (VRO) type flow control valve was designed and manufactured. In the RCPTF in KAERI, the performance tests and various kinds of transient tests of the RCP were successfully performed. In this study, H-Q curve of the pump using the VRO revealed a similar trend to the result from two ROs. The VRO was confirmed to effectively cover the full test range of the flow rate.

  10. Optical Performance Monitoring and Signal Optimization in Optical Networks

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2006-01-01

    -optical-electrical regeneration points decreases. This thesis evaluates the impact of signal degrading effects that are becoming of increasing concern in all-optical high-speed networks due to all-optical switching and higher bit-rates. Especially group-velocity-dispersion (GVD) and a number of nonlinear effects will require......The thesis studies performance monitoring for the next generation optical networks. The focus is on all-optical networks with bit-rates of 10 Gb/s or above. Next generation all-optical networks offer large challenges as the optical transmitted distance increases and the occurrence of electrical...... enhanced attention to avoid signal degradations. The requirements for optical performance monitoring features are discussed, and the thesis evaluates the advantages and necessity of increasing the level of performance monitoring parameters in the physical layer. In particular, methods for optical...

  11. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  12. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently re-emerged on the U.S. market, and they have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine the actual energy consumption of a HPWH in different U.S. regions, annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the United States. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  13. West Village Community: Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, B.; Backman, C.; Hoeschele, M.; German, A.

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. The project when complete will provide housing for students, faculty, and staff with a vision to minimize the community's impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  14. West Village Community. Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. When complete, the project will provide housing for students, faculty, and staff with a vision to minimize the community’s impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  15. Performance of hybrid quad generation system consisting of solid oxide fuel cell system and absorption heat pump

    DEFF Research Database (Denmark)

    Cachorro, Irene Albacete; Daraban, Iulia Maria; Lainé, Guillaume

    2013-01-01

    and absorption heat pump. The model is validated using data available in open literature. Overall this system shows better performance in terms of efficiency and CO2 emissions compared with cogeneration or tri-generation systems. Specifically, it suits better for applications, such food industry, where...

  16. A PERFORMANCE EVALUATION OF A VARIABLE SPEED, MIXED REFRIGERANT HEAT PUMP. SUMMARY. EPA/600/SR-92/053

    Science.gov (United States)

    The performance of an innovative heat pump, equipped with a distillation column to shift the composition of a zeotropic refrigerant mixture, was evaluated. The results of U.S. Department of Energy (DOE) rating tests and seasonal energy calcuations are reported with the main cycl...

  17. EFFECT OF LUBRICANT CONTAMINATION ON THE PERFORMANCE AND RELIABILITY OF HEAT PUMPS CHARGED WITH R-407C.

    Science.gov (United States)

    The report gives results of the development of new data that can be used to determine the effect of mineral oil contamination on the reliability of a heat pump system operating with a new hydrofluorocarbon mixture and polyol ester lubricant, to assess any performance degradation ...

  18. EFFECT OF LUBRICANT CONTAMINATION ON THE PERFORMANCE AND RELIABILITY OF HEAT PUMPS CHARGED WITH R-407C.

    Science.gov (United States)

    The report gives results of the development of new data that can be used to determine the effect of mineral oil contamination on the reliability of a heat pump system operating with a new hydrofluorocarbon mixture and polyol ester lubricant, to assess any performance degradation ...

  19. A PERFORMANCE EVALUATION OF A VARIABLE SPEED, MIXED REFRIGERANT HEAT PUMP. SUMMARY. EPA/600/SR-92/053

    Science.gov (United States)

    The performance of an innovative heat pump, equipped with a distillation column to shift the composition of a zeotropic refrigerant mixture, was evaluated. The results of U.S. Department of Energy (DOE) rating tests and seasonal energy calcuations are reported with the main cycl...

  20. Mindful awareness of feelings increases neural performance monitoring.

    Science.gov (United States)

    Saunders, Blair; Rodrigo, Achala H; Inzlicht, Michael

    2016-02-01

    Mindfulness has been associated with enhanced performance monitoring; however, little is known about the processes driving this apparent neurocognitive benefit. Here, we tested whether focusing present-moment awareness toward the nonjudgmental experience of emotion facilitates rapid neural responses to negative performance outcomes (i.e., mistakes). In particular, we compared whether directing present-moment awareness toward emotions or thoughts would enhance the neurophysiological correlates of performance monitoring: the error-related negativity (ERN) and the error positivity (Pe). Participants were randomly assigned to either a thought-focused or an emotion-focused group, and first they completed a preinduction go/no-go task. Subsequently, the groups followed inductions that promoted mindful attention toward either thoughts or emotions, before completing a final postinduction go/no-go session. The results indicated that emotion-focused participants demonstrated higher neural sensitivity to errors in the time course of the ERN, whereas focusing on thoughts had no effect on performance monitoring. In contrast, neither induction procedure altered the amplitude of the later Pe component. Although our manipulations also induced changes in behavior, the ERN effects remained significant after controlling for performance. Thus, our results suggest that mindfulness meditation boosts early neural performance monitoring (ERN amplitude), specifically through meditation's influence on affective processing.

  1. Fast Flux Test Facility Performance Monitoring Management Information August 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1989-09-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate provide one means of monitoring overall plant performance. Overall performance indicators are listed in Table 1. The ``other`` performance indicators, listed in Table 2, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. 27 figs., 2 tabs.

  2. Fast Flux Test Facility Performance Monitoring Management Information April 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D. J.

    1989-05-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the result for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. Overall performance indicators are listed. The ``other`` performance indicators, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. 26 figs., 2 tabs.

  3. Is there a difference in pregnancy and glycemic outcome in patients with type 1 diabetes on insulin pump with constant or intermittent glucose monitoring? A pilot study.

    Science.gov (United States)

    Petrovski, Goran; Dimitrovski, Cedomir; Bogoev, Milco; Milenkovic, Tatjana; Ahmeti, Irfan; Bitovska, Iskra

    2011-11-01

    The aim of the study is to describe glycemic and insulin outcomes by trimester and maternal and fetal outcome in patients with type 1 diabetes using an insulin pump with constant or intermittent continuous glucose monitoring (CGM). Twenty-five women with type 1 diabetes with newly diagnosed pregnancy were treated with insulin pump therapy (Medtronic 722, Medtronic Minimed, Northridge, CA) for at least 1 year. Insulin pump and CGM (Medtronic Paradigm Real-Time) were implemented at least 3 months before conception. Patients were randomized in two groups: constant CGM group, 12 patients on insulin pump with glucose sensor, 24 h/day; and intermittent CGM group, 13 patients on insulin pump with intermittent glucose sensor, 14 days/month. The following parameters were analyzed: glycosylated hemoglobin (HbA1c), mean blood glucose, insulin requirement (in IU/kg/day), weight gain, severe hypoglycemic events, diabetic ketoacidosis, macrosomia, cesarean section, and neonatal hypoglycemia. Both groups achieved good glucose control during their pregnancies (PInsulin pump therapy together with constant or intermittent CGM can improve diabetes control and pregnancy outcome in type 1 diabetes. The quality of the glucose profile at conception was the important factor for pregnancy outcome.

  4. Face-induced expectancies influence neural mechanisms of performance monitoring.

    Science.gov (United States)

    Osinsky, Roman; Seeger, Jennifer; Mussel, Patrick; Hewig, Johannes

    2016-04-01

    In many daily situations, the consequences of our actions are predicted by cues that are often social in nature. For instance, seeing the face of an evaluator (e.g., a supervisor at work) may activate certain evaluative expectancies, depending on the history of prior encounters with that particular person. We investigated how such face-induced expectancies influence neurocognitive functions of performance monitoring. We recorded an electroencephalogram while participants completed a time-estimation task, during which they received performance feedback from a strict and a lenient evaluator. During each trial, participants first saw the evaluator's face before performing the task and, finally, receiving feedback. Therefore, faces could be used as predictive cues for the upcoming evaluation. We analyzed electrocortical signatures of performance monitoring at the stages of cue processing, task performance, and feedback reception. Our results indicate that, at the cue stage, seeing the strict evaluator's face results in an anticipatory preparation of fronto-medial monitoring mechanisms, as reflected by a sustained negative-going amplitude shift (i.e., the contingent negative variation). At the performance stage, face-induced expectancies of a strict evaluation rule led to increases of early performance monitoring signals (i.e., frontal-midline theta power). At the final stage of feedback reception, violations of outcome expectancies differentially affected the feedback-related negativity and frontal-midline theta power, pointing to a functional dissociation between these signatures. Altogether, our results indicate that evaluative expectancies induced by face-cues lead to adjustments of internal performance monitoring mechanisms at various stages of task processing.

  5. Smart Sensing of the Aux. Feed-water Pump Performance in NPP Severe Accidents Using Advanced GMDH Method

    Energy Technology Data Exchange (ETDEWEB)

    No, Young Gyu; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    In order to develop and verify the models, a number of data obtained by simulating station black out (SBO) scenario for the optimized power reactor 1000 (OPR1000) using MARS code were used. Most of monitoring systems for component have been suggested by using the directly measured data. However, it is very difficult to acquire data related to safety-critical component' status. Therefore, it is necessary to develop the new method that combines the data-based equipped with learning system and data miming technique. Many data-based modeling methods have been applied successfully to nuclear engineering area, such as signal validation, plant diagnostics and event identification. Also, the data miming is the process of analyzing data from different perspectives and summarizing it into useful information. In this study, the smart sensing technique was developed using advanced group method of data handing (GMDH) model. The original GMDH is an inductive self organizing algebraic model. The advanced GMDH model is equipped with a fuzzy concept. The proposed advanced GMDH model enhances the original GMDH model by reducing the effect of outliers and noise. The advanced GMDH uses different weightings according to their importance which is specified by the fuzzy membership grade. The developed model was verified using SBO accident simulation data for the OPR1000 nuclear power plant acquired with MARS code. Also, the advanced GMDH model was trained using the simulated development data and verified with simulated test data. The development and test data sets were independent. The simulation results show that the performance of the developed advanced GMDH model was very satisfactory, as shown in Table 1. Therefore, if the developed model can be optimized using diverse and specific data, it will be possible to predict the performance of Aux. feed water pump accurately.

  6. Performance evaluation of a vapor compression heat pump cycle using binary zeotropic refrigerant mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Shigeru; Yara, Tomoyasu

    1999-07-01

    The HCFC refrigerants such as R22 have been used widely as working fluids in refrigeration and air-conditioning systems until now. These refrigerants, however, should be phased out early in the next century to prevent the depletion of the ozone layer. In this situation, binary and/or ternary mixtures composed of HFC and/or natural refrigerants have attracted a great deal of attention due to the following possibilities: (1) to improve the coefficient of performance, COP, by utilizing the temperature glide during phase change processes; (2) to keep the system in more suitable condition for given temperature levels of heat source and heat sink by selecting the combination and composition of refrigerants, etc. From this point of view, in the present study, the performance prediction of a vapor compression heat pump cycle using binary zeotropic refrigerant mixtures is carried out to clarify the effects of the combination of refrigerants, the composition of refrigerants and the size of heat exchangers on COP. In the prediction calculation, a vapor compression heat pump cycle, which consists of a compressor, a vertical plate-fin condenser, an expansion valve, a liquid-vapor separator and a vertical plate-fin evaporator is treated, and the following assumptions are employed: (1) the compression process is isentropic, (2) the expansion process is isenthalpic, (3) the refrigerant is a saturated liquid at the condenser outlet and a superheated vapor at the evaporator outlet, (4) the pressure drop in the condenser is negligible, while that in the evaporator is considered, (5) the local heat transfer characteristics in heat exchangers are considered. The prediction calculation is done for the binary zeotropic refrigerant mixtures of HFC134a/HCFC123 on condition that the heat source water temperature at the condenser outlet, the heat sink water temperature at the evaporator inlet, the water temperature change through condenser and evaporator, the heat load of condenser, the

  7. Preliminary Analysis of Remote Monitoring & Robotic Concepts for Performance Confirmation

    Energy Technology Data Exchange (ETDEWEB)

    D.A. McAffee

    1997-02-18

    As defined in 10 CFR Part 60.2, Performance Confirmation is the ''program of tests, experiments and analyses which is conducted to evaluate the accuracy and adequacy of the information used to determine with reasonable assurance that the performance objectives for the period after permanent closure will be met''. The overall Performance Confirmation program begins during site characterization and continues up to repository closure. The main purpose of this document is to develop, explore and analyze initial concepts for using remotely operated and robotic systems in gathering repository performance information during Performance Confirmation. This analysis focuses primarily on possible Performance Confirmation related applications within the emplacement drifts after waste packages have been emplaced (post-emplacement) and before permanent closure of the repository (preclosure). This will be a period of time lasting approximately 100 years and basically coincides with the Caretaker phase of the project. This analysis also examines, to a lesser extent, some applications related to Caretaker operations. A previous report examined remote handling and robotic technologies that could be employed during the waste package emplacement phase of the project (Reference 5.1). This analysis is being prepared to provide an early investigation of possible design concepts and technical challenges associated with developing remote systems for monitoring and inspecting activities during Performance Confirmation. The writing of this analysis preceded formal development of Performance Confirmation functional requirements and program plans and therefore examines, in part, the fundamental Performance Confirmation monitoring needs and operating conditions. The scope and primary objectives of this analysis are to: (1) Describe the operating environment and conditions expected in the emplacement drifts during the preclosure period. (Presented in Section 7.2). (2

  8. Exergy analysis of the performance of low-temperature district heating system with geothermal heat pump

    Directory of Open Access Journals (Sweden)

    Sekret Robert

    2014-03-01

    Full Text Available Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5 oC with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40 oC, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.

  9. Performance evaluation and parametric optimization of a proton exchange membrane fuel cell/heat-driven heat pump hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.; Chen, J. [Department of Physics, Xiamen University, Xiamen 361005 (China)

    2012-06-15

    With the help of the current models of proton exchange membrane (PEM) fuel cells and three-heat-source heat pumps, a generic model of a PEM fuel cell/heat-driven heat pump hybrid system is established, so that the waste heat produced in the PEM fuel cell may be availably utilized. Based on the theory of electrochemistry and non-equilibrium thermodynamics, expressions for the efficiency and power output of the PEM fuel cell, the coefficient of performance and rate of pumping heat of the heat-driven heat pump, and the equivalent efficiency and power output of the hybrid system are derived. The curves of the equivalent efficiency and power output of the hybrid system varying with the electric current density and the equivalent power output versus efficiency curves are represented through numerical calculation. The general performance characteristics of the hybrid system are analyzed. The optimally operating regions of some important parameters of the hybrid system are determined. The influence of some main irreversible losses on the performance of the hybrid system is discussed in detail. The advantages of the hybrid system are revealed. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Finite time exergoeconomic performance optimization for an irreversible universal steady flow variable-temperature heat reservoir heat pump cycle model

    Directory of Open Access Journals (Sweden)

    Huijun Feng, Lingen Chen, Fengrui Sun

    2010-11-01

    Full Text Available An irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs and the losses of heat-resistance and internal irreversibility is established by using the theory of finite time thermodynamics. The universal heat pump cycle model consists of two heat-absorbing branches, two heat-releasing branches and two adiabatic branches. Expressions of heating load, coefficient of performance (COP and profit rate of the universal heat pump cycle model are derived, respectively. By means of numerical calculations, heat conductance distributions between hot- and cold-side heat exchangers are optimized by taking the maximum profit rate as objective. There exist an optimal heat conductance distribution and an optimal thermal capacity rate matching between the working fluid and heat reservoirs which lead to a double maximum profit rate. The effects of internal irreversibility, total heat exchanger inventory, thermal capacity rate of the working fluid and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performance of the cycle are discussed in detail. The results obtained herein include the optimal finite time exergoeconomic performances of endoreversible and irreversible, constant- and variable-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles.

  11. Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Humberto E. Garcia; Wen-Chiao Lin; Semyon M. Meerkov; Maruthi T. Ravichandran

    2013-12-01

    Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

  12. Design analysis and performance assessment of hybrid magnetic bearings for a rotary centrifugal blood pump.

    Science.gov (United States)

    Ren, Zhaohui; Jahanmir, Said; Heshmat, Hooshang; Hunsberger, Andrew Z; Walton, James F

    2009-01-01

    A hybrid magnetic bearing system was designed for a rotary centrifugal blood pump being developed to provide long-term circulatory support for heart failure patients. This design consists of two compact bearings to suspend the rotor in five degrees-of-freedom with single axis active control. Permanent magnets are used to provide passive radial support and electromagnets to maintain axial stability of the rotor. Characteristics of the passive radial and active thrust magnetic bearing system were evaluated by the electromagnetic finite element analysis. A proportional-integral-derivative controller with force balance algorithm was implemented for closed loop control of the magnetic thrust bearing. The control position is continuously adjusted based on the electrical energy in the bearing coils, and thus passive magnetic forces carry static thrust loads to minimize the bearing current. Performance of the magnetic bearing system with associated control algorithm was evaluated at different operating conditions. The bearing current was significantly reduced with the force balance control method and the power consumption was below 0.5 W under various thrust loads. The bearing parameters predicted by the analysis were validated by the experimental data.

  13. Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2014

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR=1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.

  14. Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2013

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2013 for the component reliability as reported in the Institute of Nuclear Power Operations Consolidated Events Database. The TDP failure modes considered are failure to start, failure to run less than or equal to 1 hour, failure to run more than 1 hour, and (for normally running systems) failure to run. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.

  15. Fast flux test facility performance monitoring management information; June 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1989-07-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement.

  16. Fast Flux Test Facility Performance Monitoring Management Information March 1989

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D. J.

    1989-04-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other.`` The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. The data should be used in conjunction with the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. This report must be reviewed with the understanding that both the design and the mission are different for FFTF compared to commercial power reactors.

  17. Monitoring load, recovery and performance in young elite soccer players

    NARCIS (Netherlands)

    Brink, Michel S.; Nederhof, Esther; Visscher, Chris; Schmikli, Sandor L.; Lemmink, Koen A. P. M.

    2010-01-01

    Brink, MS, Nederhof, E, Visscher, C, Schmikli, SL, and Lemmink, KAPM. Monitoring load, recovery, and performance in young elite soccer players. J Strength Cond Res 24(3): 597603, 2010-The purpose of this study was to investigate the relation between training load, recovery, and monthly field test pe

  18. Mastitis diagnostics and performance monitoring: a practical approach

    NARCIS (Netherlands)

    Lam, T.J.G.M.; Olde Riekerink, R.; Sampimon, O.C.; Smith, H.E.

    2009-01-01

    In this paper a review is given of frequently used mastitis diagnostic methods in modern dairy practice. Methods used at the quarter, cow, herd and regional or national level are discussed, including their usability for performance monitoring in udder health. Future developments, such as systems in

  19. 45 CFR 2543.51 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Monitoring and reporting program performance. 2543.51 Section 2543.51 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND...

  20. The Effects of Self-Monitoring on Safe Posture Performance

    Science.gov (United States)

    Gravina, Nicole; Austin, John; Schoedtder, Lori; Loewy, Shannon

    2008-01-01

    The purpose of the present study was to examine the effects of self-monitoring on safe positioning of individuals performing a typing task and an assembly task using a multiple baseline design across behaviors and tasks. The study took place in an analogue office setting with seven college student participants. The dependent variable was the…

  1. 38 CFR 49.51 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Monitoring and reporting program performance. 49.51 Section 49.51 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... not be required more frequently than quarterly or, less frequently than annually. Annual reports...

  2. Monitoring User-System Performance in Interactive Retrieval Tasks

    NARCIS (Netherlands)

    Boldareva, L.; de Vries, A.P.; Hiemstra, Djoerd

    Monitoring user-system performance in interactive search is a challenging task. Traditional measures of retrieval evaluation, based on recall and precision, are not of any use in real time, for they require a priori knowledge of relevant documents. This paper shows how a Shannon entropy-based

  3. Monitoring user-system performance in interactive retrieval tasks

    NARCIS (Netherlands)

    L. Boldareva; A.P. de Vries (Arjen); D. Hiemstra

    2004-01-01

    textabstractMonitoring user-system performance in interactive search is a challenging task. Traditional measures of retrieval evaluation, based on recall and precision, are not of any use in real time, for they require a priori knowledge of relevant documents. This paper shows how a Shannon

  4. Monitoring user-system performance in interactive retrieval tasks

    NARCIS (Netherlands)

    Boldareva, L.; Vries, A.P. de; Hiemstra, D.

    2004-01-01

    Monitoring user-system performance in interactive search is a challenging task. Traditional measures of retrieval evaluation, based on recall and precision, are not of any use in real time, for they require a priori knowledge of relevant documents. This paper shows how a Shannon entropy-based measur

  5. Developments in Performance Monitoring of Concrete Exposed to Extreme Environments.

    OpenAIRE

    McCarter, W.J.; Chrisp, T. M.; Starrs, G.; Adamson, A.; Owens, E; Basheer, P. A. M.; Nanukuttan, S. V.; Srinivasan, S; Holmes, Niall

    2011-01-01

    The performance of the surface zone of concrete is acknowledged as a major factor governing the rate of deterioration of reinforced concrete structures because it provides the only barrier to the ingress of water containing dissolved ionic species such as chlorides, which ultimately initiate corrosion of the reinforcement. In situ monitoring of cover-zone concrete is therefore critical in attempting to make realistic predictions as to the in-service performance of the structure. To this end, ...

  6. Automated Performance Monitoring and Assessment for DCS Digital Systems.

    Science.gov (United States)

    1977-10-01

    eye opening monitor performance assessment techniques. (3) Implement and program a CPMAS test processor subsystem. (4) Perform a field test site...an internodal path in the planned DEB network is 11 ( Hillingdon to Schoenfeld). For this reason, the path from Node A to Node B in the Transmission...RADIOS SITE RADIOS HOHENSTADT 4 BANN 6 STUTTGART 4 HILLINGDON 3 LANGERKOPF 5 CROUGHTON 4 DONNERSBERG 10 MARTLESHAM HEATH 3 PIRMASENS 4 ADENAU 3

  7. Fast Beam Condition Monitor for CMS: performance and upgrade

    CERN Document Server

    Leonard, Jessica Lynn; Burtowy, Piotr; Dabrowski, Anne; Hempel, Maria; Henschel, Hans; Lange, Wolfgang; Lohmann, Wolfgang; Odell, Nathaniel; Penno, Marek; Pollack, Brian; Przyborowski, Dominik; Ryjov, Vladimir; Stickland, David; Walsh, Roberval; Warzycha, Weronika; Zagozdzinska, Agnieszka

    2014-01-01

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

  8. New analysis and performance of a wall-current monitor

    Energy Technology Data Exchange (ETDEWEB)

    Suwada, T.; Urano, T.; Kobayashi, H. [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Tamiya, K.; Asami, A. [Naruto University of Education, Takashima, Naruto-cho, Naruto-shi 772 (Japan)

    1997-09-01

    A new wall-current monitor has been developed in order to reinforce the beam-monitoring system in the PF 2.5-GeV linac for the KEK B-Factory. A prototype monitor was tested for its performance and characteristics. The experimental results in terms of both bench tests and beam tests by single-bunch electron beams were analyzed on the basis of equivalent-circuit models. The frequency response of the monitor agreed well with a lumped equivalent-circuit model for both time- and frequency-domain measurements. The position dependence and its frequency characteristics of the monitor also agreed well with a distributed equivalent-circuit model for both time- and frequency-domain measurements. The rise time of the monitor was about 3 ns, which indicated a poor response for short-pulse beams (<1) ns. The reason could be attributed to the stray inductance of the ceramic solid resistor and not very good frequency response of the ferrite core. (orig.).

  9. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-03-01

    Full Text Available The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.

  10. Advanced Performance Modeling with Combined Passive and Active Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Dovrolis, Constantine [Georgia Inst. of Technology, Atlanta, GA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-04-15

    To improve the efficiency of resource utilization and scheduling of scientific data transfers on high-speed networks, the "Advanced Performance Modeling with combined passive and active monitoring" (APM) project investigates and models a general-purpose, reusable and expandable network performance estimation framework. The predictive estimation model and the framework will be helpful in optimizing the performance and utilization of networks as well as sharing resources with predictable performance for scientific collaborations, especially in data intensive applications. Our prediction model utilizes historical network performance information from various network activity logs as well as live streaming measurements from network peering devices. Historical network performance information is used without putting extra load on the resources by active measurement collection. Performance measurements collected by active probing is used judiciously for improving the accuracy of predictions.

  11. Performance Assessment and Active System Monitoring for Refrigeration Systems

    DEFF Research Database (Denmark)

    Green, Torben

    for algorithms that ensures or improves the performance of the system. A supermarket refrigeration system is usually a complex and distributed control system, and it can therefore be difficult to assess the performance without a formal method. The main interest for a supermarket, with respect...... of the refrigeration system has been addressed in the project. The proposed methods for improvement relies on a minimum of detailed knowledge about the refrigeration system. In addition, since a refrigeration system often operates in steady state an active system monitoring setup has been proposed, to enable...... a method for assessing the operational performance at a plan-wide level and is therefore providing a tool for improving the plant-wide performance. The performance function has been used in dierent setups to improve the performance of the refrigeration system. Static and the dynamic performance...

  12. Sprint Running Performance Monitoring: Methodological and Practical Considerations.

    Science.gov (United States)

    Haugen, Thomas; Buchheit, Martin

    2016-05-01

    The aim of this review is to investigate methodological concerns associated with sprint performance monitoring, more specifically the influence and magnitude of varying external conditions, technology and monitoring methodologies not directly related to human physiology. The combination of different starting procedures and triggering devices can cause up to very large time differences, which may be many times greater than performance changes caused by years of conditioning. Wind, altitude, temperature, barometric pressure and humidity can all combine to yield moderate time differences over short sprints. Sprint performance can also be affected by the athlete's clothing, principally by its weight rather than its aerodynamic properties. On level surfaces, the track compliance must change dramatically before performance changes larger than typical variation can be detected. An optimal shoe bending stiffness can enhance performance by a small margin. Fully automatic timing systems, dual-beamed photocells, laser guns and high-speed video are the most accurate tools for sprint performance monitoring. Manual timing and single-beamed photocells should be avoided over short sprint distances (10-20 m) because of large absolute errors. The validity of today's global positioning systems (GPS) technology is satisfactory for long distances (>30 m) and maximal velocity in team sports, but multiple observations are still needed as reliability is questionable. Based on different approaches used to estimate the smallest worthwhile performance change and the typical error of sprint measures, we have provided an assessment of the usefulness of speed evaluation from 5 to 40 m. Finally, we provide statistical guidelines to accurately assess changes in individual performance; i.e. considering both the smallest worthwhile change in performance and the typical error of measurement, which can be reduced while repeating the number of trials.

  13. Sampling and Filtering in Photovoltaic System Performance Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Driesse, Anton [PV Performance Labs, Freiburg (Germany); Stein, Joshua S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Riley, Daniel M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Carmignani, Craig K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration

    2014-10-01

    The performance of photovoltaic systems must be monitored accurately to ensure profitable long-term operation. The most important signals to be measured—irradiance and temperature, as well as power, current and voltage on both DC and AC sides of the system—contain rapid fluctuations that are not observable by typical monitoring systems. Nevertheless these fluctuations can affect the accuracy of the data that are stored. This report closely examines the main signals in one operating PV system, which were recorded at 2000 samples per second. It analyzes the characteristics and causes of the rapid fluctuations that are found, such as line-frequency harmonics, perturbations from anti-islanding detection, MPPT searching action and others. The operation of PV monitoring systems is then simulated using a wide range of sampling intervals, archive intervals and filtering options to assess how these factors influence data accuracy. Finally several potential sources of error are discussed with real-world examples.

  14. Integrating policy-based management and SLA performance monitoring

    Science.gov (United States)

    Liu, Tzong-Jye; Lin, Chin-Yi; Chang, Shu-Hsin; Yen, Meng-Tzu

    2001-10-01

    Policy-based management system provides the configuration capability for the system administrators to focus on the requirements of customers. The service level agreement performance monitoring mechanism helps system administrators to verify the correctness of policies. However, it is difficult for a device to process the policies directly because the policies are the management concept. This paper proposes a mechanism to decompose a policy into rules that can be efficiently processed by a device. Thus, the device may process the rule and collect the performance statistics information efficiently; and the policy-based management system may collect these performance statistics information and report the service-level agreement performance monitoring information to the system administrator. The proposed policy-based management system achieves both the policy configuration and service-level agreement performance monitoring requirements. A policy consists of a condition part and an action part. The condition part is a Boolean expression of a source host IP group, a destination host IP group, etc. The action part is the parameters of services. We say that an address group is compact if it only consists of a range of IP address that can be denoted by a pair of IP address and corresponding IP mask. If the condition part of a policy only consists of the compact address group, we say that the policy is a rule. Since a device can efficiently process a compact address and a system administrator prefers to define a range of IP address, the policy-based management system has to translate policy into rules and supplements the gaps between policy and rules. The proposed policy-based management system builds the relationships between VPN and policies, policy and rules. Since the system administrator wants to monitor the system performance information of VPNs and policies, the proposed policy-based management system downloads the relationships among VPNs, policies and rules to the

  15. Development and Qualification of Advancements in Submersible Transfer Pump Performance and Life, and Implications for Advancing and Supporting Processing Options - 13343

    Energy Technology Data Exchange (ETDEWEB)

    Stover, David L. [Curtiss-Wright EMD, Cheswick, PA 15024 (United States); Bryan, Wes; Kelly, James [Washington River Protection Solutions, Richland, WA 99352 (United States)

    2013-07-01

    From the 1950's through the 1990's, relatively inexpensive, 'off-the-shelf' type, vertical turbine pumps (VTP) were used to transfer Hanford waste. The technology of those pumps was rooted primarily in the mining and agricultural (irrigation) industries. HNF-3218, Double Shell Tank (DST) Transfer Pump History and Reliability Report, 1998, provides a summary of Hanford DST pump history to that date. Such pumps operated in the Hanford radioactive waste environment for an average of only 400 hours before failure. However, at that time, operating life was not a driving criteria within the Department of Energy (DOE) complex, as the failure of transfer pumps represented a relatively low replacement and disposal cost. The Environmental Protection Agency (EPA) issuance of the 'Debris Rule' in 1992, which mandated that mixed radioactive waste contaminated equipment be decontaminated to a 'low level waste' category prior to burial, elevated the significance of transfer pump reliability and decontamination capability as life-cycle cost criteria. Minimizing the frequency of transfer pump failures and design for decontamination became significantly important and served to drive the need toward specific, designed for application pumps to meet this challenge. To this end, Washington River Protection Solutions (WRPS) and the supplier, Curtiss-Wright EMD (EMD), have recently collaborated on an intense program to further transfer pump technology and performance. (authors)

  16. Tip clearance effects on loads and performances of semi-open impeller centrifugal pumps at different specific speeds

    Science.gov (United States)

    Boitel, G.; Fedala, D.; Myon, N.

    2016-11-01

    Relevant industrial standards or customer's specifications could strictly forbid any device adjusting the axial rotor/stator position, so that tip clearance between semi-open impeller and casing might become a result of the pump machining tolerances and assembling process, leading to big tip clearance variations compared to its nominal value. Consequently, large disparities of global performances (head, power, efficiency) and axial loads are observed with high risk of both specifications noncompliance and bearing damages. This work aims at quantifying these variations by taking into account tip clearance value and pump specific speed. Computational Fluid Dynamics is used to investigate this phenomenon by means of steady simulations led on a semi-open centrifugal pump numerical model including secondary flows, based on a k-omega SST turbulence model. Four different specific speed pump sizes are simulated (from 8 to 50, SI units), with three tip clearances for each size on a wide flow range (from 40% to 120% of the best efficiency point). The numerical results clearly show that head, power and efficiency increase as the tip clearance decreases for the whole flow range. This effect is more significant when the specific speed is low. Meanwhile, the resulting axial thrust on the impeller is very sensitive to the tip clearance and can even lead to direction inversion.

  17. Enhanced performance of thin-disk lasers by pumping into the zero-phonon line.

    Science.gov (United States)

    Weichelt, Birgit; Voss, Andreas; Abdou Ahmed, Marwan; Graf, Thomas

    2012-08-01

    Pumping Yb:YAG or Yb:LuAG into the zero-phonon line at 969 nm instead of using the common pump wavelength of 940 nm reduces the heat generation by 32%. In addition to the 3% increase of the Stokes efficiency, this significantly reduces the diffraction losses caused by the thermally induced phase distortions leading to a remarkable increase of the overall efficiency especially of fundamental-mode thin-disk lasers. Using this pumping scheme in an Yb:LuAG thin-disk laser, we achieved 742 W of nearly diffraction limited (M2≈1.5) output power at an unprecedented high optical efficiency of 58.5%. For multimode operation (M2≈15) the maximum optical efficiency of an Yb:YAG thin-disk laser was increased to 72%.

  18. A Detailed Experimental Study on Single-Pump Raman/EDFA Hybrid Amplifiers: Static, Dynamic, and System Performance Comparison

    Science.gov (United States)

    Lee, Ju Han; Chang, You Min; Han, Young Geun; Chung, Haeyang; Hyuck Kim, Sang; Lee, Sang Bae

    2005-11-01

    This paper presents an experimental study on the performance comparison of three different schemes of single-pump dispersion-compensating fiber (DCF)-based Raman/erbium-doped fiber amplifier (EDFA) hybrid amplifiers together with a DCF-based Raman-only amplifier in terms of static properties, dynamic properties, and system impact: Raman-only amplifier (Type I), Raman/EDFA hybrid amplifiers recycling residual Raman pump in a cascaded EDF located either after (Type II) or prior to (Type III) a DCF, and a Raman-assisted EDFA (Type IV), the concept of which was proposed by Kurosawa With respect to the overall gain and system impact based on bit error rate (BER) measurements in a transmission system, the hybrid amplifier of Type II was found to have the best performance among the four types while the Raman-only amplifier shows the best tolerance to transient response.

  19. IMPROVE THE KINETIC PERFORMANCE OF THE PUMP CONTROLLED CLAMPING UNIT IN PLASTIC INJECTION MOLDING MACHINE WITH ADAPTIVE CONTROL STRATEGY

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The kinetic characteristics of the clamping unit of plastic injection molding machine that is controlled by close loop with newly developed double speed variable pump unit are investigated.Considering the wide variation of the cylinder equivalent mass caused by the transmission ratio of clamping unit and the severe instantaneous impact force acted on the cylinder during the mold closing and opening process, an adaptive control principle of parameter and structure is proposed to improve its kinetic performance. The adaptive correlation between the acceleration feedback gain and the variable mass is derived. The pressure differential feedback is introduced to improve the dynamic performance in the case of small inertia and heavy impact load. The adaptation of sum pressure to load is used to reduce the energy loss of the system. The research results are verified by the simulation and experiment. The investigation method and the conclusions are also suitable for the differential cylinder system controlled by the traditional servo pump unit.

  20. Annual investigation of vertical type ground source heat pump system performance on a wall heating and cooling system in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Akbulut, U.; Yoru, Y.; Kincay, O. [Department of Mechanical Engineering, Yildiz Technical University (Turkey)], email: akbulutugur@yahoo.com, email: yilmazyoru@gmail.com, email: okincay@yildiz.edu.tr

    2011-07-01

    Wall heating and cooling systems (WHCS) are equipped with heating serpentines or panels for water circulation. These systems operate in a low temperature range so they are preferable to other, conventional systems. Furthermore, when these systems are connected to a ground source heat pump (GSHP) system, energy performance and thermal comfort are further enhanced. The purpose of this paper is to report the results of an annual inspection done on a vertical type ground-coupled heat pump systems (V-GSHP) WHCS in Istanbul and present the results. The performance data from the Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University, Istanbul, Turkey, during the year 2010 were collected and analyzed. The conclusions drawn from the inspection and analysis were listed in this paper. Using renewable energy sources effectively will bring both economic and environmental benefits and it is hoped that the use of these energy efficient WHCS systems will become widespread.

  1. Performance analysis and optimization for an endoreversible Carnot heat pump cycle with finite speed of the piston

    Directory of Open Access Journals (Sweden)

    Bo Yang, Lingen Chen, Fengrui Sun

    2011-11-01

    Full Text Available Performance of an endoreversible Carnot heat pump cycle with finite speed of the piston is investigated by using finite time thermodynamics. The analytical formulae between the optimal heating load and the coefficient of performance (COP, as well as between the optimal heating load and speed ratio of the piston are derived. It is found that the heating load versus COP characteristics are parabolic-like, and there exist a maximum heating load and the corresponding COP. These are different from the monotonically decreasing characteristic of the endoreversible Carnot heat pump without consideration of the finite speed of the piston. At the same time, the effects of reservoir temperature ratio on the optimal relations are analyzed by numerical examples. In the analysis and optimization, two cases with and without limit of cycle period are included.

  2. 用引射技术提高离心泵的汽蚀性能%Improving suction performance of Centrifugal Pumps by Using Jetting Device

    Institute of Scientific and Technical Information of China (English)

    崔宝玲; 朱祖超; 张剑慈; 吴昱; 陈鹰

    2004-01-01

    Improving the suction performance of centrifugal pumps by using jetting device is presented. The theoretical analysis, experimental study and engineering implementation show that suction performance of centrifugal pump can be improved with jetting device and be used for delivering the liquid media requiring high suction performance, whereas the efficiency and head of the pump will decrease a little. The effect of feed-back jetting on suction performance is the most obvious at design point. The suitable rate of feed-back flow is 2%-5%.

  3. End pumped yellow laser performance of Dy3+:ZnWO4

    Science.gov (United States)

    Xia, Zhongchao; Yang, Fugui; Qiao, Liang; Yan, Fengpo

    2017-03-01

    We report an end pumped single transverse-mode (TEM00) yellow laser based on Dy3+:ZnWO4 crystal. The pump light is InGaN blue laser diode at 450 nm with the maximum power of 1.5 W. A 3 cm length Dy3+:ZnWO4 crystal served as the gain medium. By way of the square filter, we discuss the TEM00 properties. In continuous-wave operation and single transverse-mode, a maximum output power of 0.110 W and a slope efficiency of 13.0% are achieved at an emission wavelength of 575 nm.

  4. Complete Web Monitoring Watching Performance, Users, and Communities

    CERN Document Server

    Croll, Alistair

    2009-01-01

    Complete Web Monitoring demonstrates how to measure every aspect of your web presence -- including analytics, backend performance, usability, communities, customer feedback, and competitive analysis -- whether you're running an e-commerce site, a community, a media property, or a Software-as-a-Service company. This book's concrete examples, clear explanations, and practical recommendations make it essential for anyone who runs a website.

  5. Evaluation of Activity Recognition Algorithms for Employee Performance Monitoring

    OpenAIRE

    2012-01-01

    Successful Human Resource Management plays a key role in success of any organization. Traditionally, human resource managers rely on various information technology solutions such as Payroll and Work Time Systems incorporating RFID and biometric technologies. This research evaluates activity recognition algorithms for employee performance monitoring. An activity recognition algorithm has been implemented that categorized the activity of employee into following in to classes: job activities and...

  6. Design, Monitoring, and Validation of a High Performance Sustainable Building

    Science.gov (United States)

    2013-08-01

    system Rainwater collected by roof and drains to the 10,000 gallon cistern below grade Not applicable Sewage conveyance Rainwater Potable water...rating system was used as the baseline for the whole building design objectives. Monitoring data for energy and water use were collected at the...performance metrics that address the research needs and sustainable design goals of the project b. establish data collection system that allows for data

  7. The Sloan Digital Sky Survey Telescope Performance Monitor

    Science.gov (United States)

    McGehee, Peregrine M.; Brinkmann, Jon; Rockosi, Constance M.; Long, Dan; Snedden, Stephanie A.; Kleinman, S. J.; Nitta, Atsuko; Harvanek, Michael; Newman, Peter R.; Neilsen, Eric H., Jr.; Krzesinski, Jurek

    2002-12-01

    The Telescope Performance Monitor (TPM) installed at the Sloan Digital Sky Survey (SDSS) located at Apache Point Observatory provides access to real-time and archived engineering data. The modularity present in the underlying Experimental Physics and Industrial Control System (EPICS) toolkit allows the observers and operations staff to develop their own approaches to data access and analysis. These techniques are summarized and the use of the TPM to solve critical project issues including analysis and correction of thermal management problems are presented.

  8. New JSME standard S008 “Performance Conversion Method for Hydraulic Turbines and Pump-Turbines”

    Science.gov (United States)

    Nakanishi, Y.; Kitahora, T.; Suzuki, S.; Suzuki, T.; Sugishita, K.; Suzuki, R.; Tani, K.

    2016-11-01

    JSME Standard S008 “Performance Conversion Method for Hydraulic Turbines and Pump-Turbines” is now being revised and will be published in 2016. This new revision follows the main theory of previous version S008-1999. It enables us to convert the performance of each flow passage component of spiral case, stay vane, guide vane, runner and draft tube of model turbines and pump-turbines to that of prototypes with one-step calculation. The relevant values needed for the performance conversion, e.g. dimension factor, flow velocity factor, relative scalable loss of components δ ECO , etc. are newly organized as functions of specific speeds of turbines and pump-turbines using polynomial expressions. Additional data for high specific speed turbines are included. The resultant factors for conversion of the specific energy efficiency scale factor F E , the discharge efficiency scale factor F Q and the power efficiency scale factor F T are determined by considering friction coefficient ratio for prototype to the model.

  9. Assessment of power step performances of variable speed pump-turbine unit by means of hydro-electrical system simulation

    Science.gov (United States)

    Béguin, A.; Nicolet, C.; Hell, J.; Moreira, C.

    2017-04-01

    The paper explores the improvement in ancillary services that variable speed technologies can provide for the case of an existing pumped storage power plant of 2x210 MVA which conversion from fixed speed to variable speed is investigated with a focus on the power step performances of the units. First two motor-generator variable speed technologies are introduced, namely the Doubly Fed Induction Machine (DFIM) and the Full Scale Frequency Converter (FSFC). Then a detailed numerical simulation model of the investigated power plant used to simulate power steps response and comprising the waterways, the pump-turbine unit, the motor-generator, the grid connection and the control systems is presented. Hydroelectric system time domain simulations are performed in order to determine the shortest response time achievable, taking into account the constraints from the maximum penstock pressure and from the rotational speed limits. It is shown that the maximum instantaneous power step response up and down depends on the hydro-mechanical characteristics of the pump-turbine unit and of the motor-generator speed limits. As a results, for the investigated test case, the FSFC solution offer the best power step response performances.

  10. Fast Flux Test Facility performance monitoring management information, October 1988

    Energy Technology Data Exchange (ETDEWEB)

    Newland, D J

    1988-11-01

    The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ``overall`` and ``other``. The ``overall`` performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance. Overall performance indicators are listed in Table 1. The ``other`` performance indicators, listed in Table 2, are considered useful management tools for assessing the specific areas they address. The data should be used in conjunction with the the results of other management assessment activities to focus improvement efforts. Use of these key performance indicators as a group is stressed, since focusing on a single indicator or a narrow set of indicators can be counterproductive both to safety and to long-term performance improvement. Any concerns regarding the accuracy or analysis of the specific indicator should be addressed to the responsible manager identified on the figure. This report must be reviewed with the understanding that both the design and the mission are different for FFTF compared to commercial power reactors. 26 figs.

  11. Novel anomaly detection approach for telecommunication network proactive performance monitoring

    Institute of Scientific and Technical Information of China (English)

    Yanhua YU; Jun WANG; Xiaosu ZHAN; Junde SONG

    2009-01-01

    The mode of telecommunication network management is changing from "network oriented" to "subscriber oriented". Aimed at enhancing subscribers'feeling, proactive performance monitoring (PPM) can enable a fast fault correction by detecting anomalies designating performance degradation. In this paper, a novel anomaly detection approach is the proposed taking advantage of time series prediction and the associated confidence interval based on multiplicative autoregressive integrated moving average (ARIMA). Furthermore, under the assumption that the training residual is a white noise process following a normal distribution, the associated confidence interval of prediction can be figured out under any given confidence degree 1-α by constructing random variables satisfying t distribution. Experimental results verify the method's effectiveness.

  12. Any link between sexual inactivity and treadle pump performance characteristics: The Malawi case

    Science.gov (United States)

    Joseph, Chidanti-Malunga; Yamikani, Malunga

    In mitigating the effects of climate change in Malawi, government promotes the use of low cost irrigation technologies to small-scale farmers, especially in wetlands where water is available. The treadle pump is one such technology. The pump is a manual water lifting device operated by feet. Although the technology has been widely accepted by small-scale farmers, there are documented reports that some farmers abandon the technology, preferring other technologies such as river diversion. One theory for the abandonment is that female farmers claim that the technology makes their male counterparts sexually inactive. This research seeks to find an explanation to the misconception. The study analyzed the physical characteristics of the treadle pump and its users. The results show that the technology is male-dominated (30% were females out of a sample of 40). The results also show that the technology is labor-intensive with very small discharge rates (an average of 0.78 l/s) achieved regardless of the BMI of the operator. With such small discharge rates, in order to fulfill irrigation requirements of a crop, the operator has to pump for long hours. This exercise makes men naturally tired, perhaps making them sexually inactive as well.

  13. Performance of ultra low temperature district heating systems with utility plant and booster heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Thorsen, Jan Eric; Markussen, Wiebke Brix

    2017-01-01

    and power (CHP) and central heat pumps (HPs). The analysis focussed on the characteristic heat demands of newly build multi-story buildings and the results were based on the ratio of the individual demands compared to the total. It was found that the optimal return temperature was dependent on the forward...

  14. Performance-oriented Analysis of a Hybrid magnetic Assembly for a Heat-pump Magnetocaloric Device

    DEFF Research Database (Denmark)

    Insinga, Andrea Roberto; Smith, Anders; Bahl, Christian R.H.

    2014-01-01

    Conventional active-regenerator magnetocaloric devices include moving parts, with the purpose of generating an oscillating magnetic field in the magneto-caloric material, placed inside the regenerator. In this work a different design is analyzed, for application in a magnetocaloric heat pump...

  15. Design and performance of main vacuum pumping system of SST-1 Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Ziauddin, E-mail: ziauddin@ipr.res.in; Pathan, Firozkhan; George, Siju; Dhanani, Kalpesh; Paravastu, Yuvakiran; Semwal, Pratibha; Pradhan, Subrata

    2014-01-15

    Highlights: •SST-1 Tokamak was successfully commissioned. •Vacuum vessel and cryostat were pumped down to 6.3 × 10{sup −7} mbar and 1.3 × 10{sup −5} mbar. •Leaks developed during baking were detected in-situ by RGA and confirmed later on. •Cryo-pumping effect was observed when LN2 thermal shields reached below 273 K. •Non-standard aluminum wire-seals have shown leak tightness < 1.0 × 10{sup −9} mbar l/s. -- Abstract: Steady-state Superconducting Tokamak (SST-1) was installed and it is commissioning for overall vacuum integrity, magnet systems functionality in terms of successful cool down to 4.5 K and charging up to 10 kA current was started from August 2012. Plasma operation of 100 kA current for more than 100 ms was also envisaged. It is comprised of vacuum vessel (VV) and cryostat (CST). Vacuum vessel, an ultra-high (UHV) vacuum chamber with net volume of 23 m{sup 3} was maintained at the base pressure of 6.3 × 10{sup −7} mbar for plasma confinement. Cryostat, a high-vacuum (HV) chamber with empty volume 39 m{sup 3} housing superconducting magnet system, bubble thermal shields and hydraulics for these circuits, maintained at 1.3 × 10{sup −5} mbar in order to provide suitable environment for these components. In order to achieve these ultimate vacuums, two numbers of turbo-molecular pumps (TMP) are installed in vacuum vessel while three numbers of turbo-molecular pumps are installed in cryostat. Initial pumping of both the chambers was carried out by using suitable Roots pumps. PXI based real time controlled system is used for remote operation of the complete pumping operation. In order to achieve UHV inside the vacuum vessel, it was baked at 150 °C for longer duration. Aluminum wire-seals were used for all non-circular demountable ports and a leak tightness < 1.0 × 10{sup −9} mbar l/s were achieved.

  16. Nova Scotia S-2000 monitoring project. Vol. 1, Performance summary

    Energy Technology Data Exchange (ETDEWEB)

    Makuch, P.; Harrison, S.J. [Queen`s Univ., Kingston, ON (Canada). Solar Calorimetry Lab.

    1994-12-01

    Electric utility companies have increasingly been evaluating and implementing demand management and conservation. As a result there has been growing interest in potential energy savings and capacity benefits of Solar Domestic Hot Water (SDHW) technologies. A computer simulation study showed that SDHW can provide significant savings in hot water heating. Natural Resources Canada through the Canada Centre for Mineral and Energy Technology (CANMET) initiated the S-2000 program. The S-2000 program was initiated to promote cooperation between CANMET, electric utilities and provincial governments interested in determining whether SDHW systems can reduce peak energy demand and pollution emissions. 60 SDHW systems were installed in Nova Scotia. Systems were monitored by Thermo Dynamics Limited and analyzed by the Solar Calorimetry Laboratory at Queen`s University. Results were produced for the monitoring period from October 1993 to August 1994. Results for 32 of the Nova Scotia systems showed winter and summer solar energy supplies of 14.8 MWh and 30 MWh respectively. The system efficiency was determined to be 28.4%. The system performance was consistent with predictions made from computer simulations, with the exception of an unexpectedly severe winter. The solar energy contribution during the winter was lower than that predicted for typical weather conditions. Of the systems monitored daily average hot water use was lower than the reference 239 L/day value. Monitoring of the Nova Scotia systems will continue through 1995 and strategies will be investigated. 15 figs., 5 tables

  17. Do Brazilian Credit Unions Adopt International Performance Monitoring?

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Magalhães Oliveira

    2015-08-01

    Full Text Available Purpose: The study examined if the Brazilian credit unions use the 'PEARLS' performance monitoring methodology proposed by the World Council of Credit Unions, and the perception of the analysts of the cooperative system on the relevance of the indicators of this system.Methods: We used qualitative research with a sample selected through accessibility. Data were obtained from structured interviews conducted with five analysts of Brazil's Central Bank and two managers of central credit cooperatives, in addition to response, via questionnaire, of seventeen managers of credit unions located in the northern, northeast, south and southeast regions of Brazil.Results: Most of the individual cooperatives and the two central credit unions analyzed were unaware of the PEARLS methodology. This monitoring system is known only by the analysts of the Central Bank of Brazil, indicating that only the supervisory agent of cooperatives in Brazil knows the internationally proposed system and the adapted version proposed to Brazilian reality.Limitations: The survey via questionnaires obtained only 1,4% of population response rate, and the results can not be generalized.Practical implications: It can be said that there is room for improving performance monitoring techniques, as the PEARLS is used in 97 countries and unknown both by individual cooperatives and credit central cooperatives surveyed in this study.Originality: It is noteworthy that studies of this problem applied to the Brazilian reality were not found to date.

  18. UCIMS: Advances in geotechnical construction and performance monitoring

    Directory of Open Access Journals (Sweden)

    Raphael Siebenmann

    2015-04-01

    Full Text Available The Crossrail project currently under construction in Central London has been described as “The Big Dig on Steroids”, obviously referencing the Central Artery/Tunnel project in Boston completed in 2007. To address the multiple demands for timely construction performance monitoring, Crossrail envisioned the underground construction information management system (UCIMS to monitor construction progress and structural health along the entire route, with a network of geotechnical instruments (i.e. slope inclinometers, extensometers, piezometers, etc. and tunnel boring machine (TBM position information. The UCIMS is a geospatially referenced relational database that was developed using an open source geographic information system (GIS that allowed all stakeholders near immediate feedback of construction performance. The purpose of this article is to provide a brief history of geotechnical and structural monitoring software, to describe the structure and operation of the UCIMS, and to demonstrate how the functionality afforded by this system provided the requisite feedback to the stakeholders. Examples will be given regarding how the data management and visualization concepts incorporated into the UCIMS advanced the geotechnical construction industry.

  19. UCIMS:Advances in geotechnical construction and performance monitoring

    Institute of Scientific and Technical Information of China (English)

    Raphael Siebenmann a; Hai-Tien Yu b; Robert Bachus a

    2015-01-01

    The Crossrail project currently under construction in Central London has been described as“The Big Dig on Steroids”, obviously referencing the Central Artery/Tunnel project in Boston completed in 2007. To address the multiple demands for timely construction performance monitoring, Crossrail envisioned the underground construction information management system (UCIMS) to monitor construction progress and structural health along the entire route, with a network of geotechnical instruments (i.e. slope in-clinometers, extensometers, piezometers, etc.) and tunnel boring machine (TBM) position information. The UCIMS is a geospatially referenced relational database that was developed using an open source geographic information system (GIS) that allowed all stakeholders near immediate feedback of con-struction performance. The purpose of this article is to provide a brief history of geotechnical and structural monitoring software, to describe the structure and operation of the UCIMS, and to demon-strate how the functionality afforded by this system provided the requisite feedback to the stakeholders. Examples will be given regarding how the data management and visualization concepts incorporated into the UCIMS advanced the geotechnical construction industry.

  20. Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances

    Directory of Open Access Journals (Sweden)

    Yue Hao

    2017-01-01

    Full Text Available The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.

  1. Experimental studies into the dependences of the axial lead coolant pump performance on the impeller cascade parameters

    Directory of Open Access Journals (Sweden)

    A.V. Beznosov

    2017-06-01

    Full Text Available The paper presents results of experimental studies into the dependences of the axial lead coolant pump performance (delivery, head, efficiency on the impeller cascade parameters, including the number of blades, the cascade blade angle and the cascade solidity. The studies were conducted as applied to conditions of small and medium sized plants based on lead cooled fast neutron reactors with horizontal steam generators. The designs of such plants are now in the process of elaboration at Nizhny Novgorod State Technical University (NNSTU. The studies were conducted at NNSTU's FT-4 test facility at a lead coolant temperature of 440–500°C. In the process of investigations, the number of blades in the form of flat plates was 3, 4, 6 and 8, the cascade blade angle was in a range of 9–43°, and the cascade solidity (0.6–1.2 was changed by changing the blade section chord length. The shaft speed of the NNSTU's NSO-01 pump, onto which changeable impellers were installed, was changed in steps of 100 rev/min in an interval of 600–1100 rev/min. The blade diameter was about 200mm, and the maximum lead coolant flow rate in the course of the tests reached ∼2000t/h. The performance of 27 impellers was investigated. It is recommended that the investigation results should be used in design of axial HLMC pumps.

  2. Suppression of Performance Curve Instability of an Axial-Flow Pump by Using a Double-Inlet-Nozzle

    Directory of Open Access Journals (Sweden)

    P. Pérez Flores

    2008-01-01

    Full Text Available It has been shown that the sudden decrease of pump head in an axial flow pump caused by stall can be overcome by means of casing treatment. Flat axial grooves in front of the impeller break the swirl of the near-casing backflow. The disadvantage of this method is strong cavitation at the inlet of the grooves for flow rates below the stall point. In this paper another improved method to stabilize the performance curve will be presented, using a double-inlet-nozzle. At the onset of stall the initial near-casing backflow with its high swirl is lead off into the gap between both nozzles. At design conditions this double-inlet-nozzle is working as an injector, supporting the near-casing-inflow. The function of the double-inlet-nozzle is demonstrated by PIV-measurements.

  3. Intelligent monitor and control system for concrete pump based on PLC%基于PLC的混凝土泵智能监测和控制系统

    Institute of Scientific and Technical Information of China (English)

    刘会勇; 李伟; 彭秀英; 胡园; 赵青

    2011-01-01

    混凝土泵向提高工作可靠性和效率、系统化、智能化、多功能化等方向发展.为了确保混凝土泵在工作时能达到规定的技术状态、降低维修成本、提高可靠性和寿命,应在整合现有电液控制方式的基础上,采用先进的传感器检测技术和计算机技术,设计和开发功能完备的混凝土泵智能监测和控制系统.首先介绍了混凝土泵智能监测和控制系统功能,然后阐述了混凝土泵智能监测和控制系统的硬件结构和软件设计,可以为其他工程机械的智能监测和控制系统的设计提供参考.%The development trend for concrete pump is geared to the improving working reliability and effciency,systematization,intelligentization,multi-functionization etc. To make sure the concrete pump reach the prescriptive technical state during working, reduce the maintenance costs and improve the reliability and longevity,the concrete pump intelligent monitor and control system with complete functions should be designed by using the advanced sensor technology and computer technology base on integrating the existing electro-hydraulic control.Firstly,the function of the concrete pump intelligent monitor and control system was introduced. Then,the hardware structure and software design of the system was described,which shall provide reference to design the intelligent monitor and control system for other construction machinery.

  4. Integrated System for Performance Monitoring of ATLAS TDAQ Network

    CERN Document Server

    Savu, D; The ATLAS collaboration; Martin, B; Sjoen, R; Batraneanu, S; Stancu, S

    2010-01-01

    The ATLAS TDAQ Network consists of three separate networks spanning four levels of the experimental building. Over 200 edge switches and 5 multi-blade chassis routers are used to interconnect 2000 processors, adding up to more than 7000 high speed interfaces. In order to substantially speed-up ad-hoc and post mortem analysis, a scalable, yet flexible, integrated system for monitoring both network statistics and environmental conditions, processor parameters and data taking characteristics was required. For successful up-to-the-minute monitoring, information from many SNMP compliant devices, independent databases and custom APIs was gathered, stored and displayed in an optimal way. Easy navigation and compact aggregation of multiple data sources were the main requirements; characteristics not found in any of the tested products, either open-source or commercial. This paper describes how performance, scalability and display issues were addressed and what challenges the project faced during development and deplo...

  5. PERFORMANCE OPTIMIZATION OF THE DIODE-PUMPED SOLID-STATE LASER FOR SPACE APPLICATIONS

    Directory of Open Access Journals (Sweden)

    D. A. Arkhipov

    2015-11-01

    Full Text Available Subject of Research. Thermophysical and optical techniques of parameter regulation for diode pumped solid-state laser are studied as applied to space laser communication and laser ranging lines. Methods. The investigations are carried out on the base of the original design of diode pumped solid-state laser module that includes the following: Nd:YAG slab element, diode pumped by 400W QCW produced by NORTHROP GRUMMAN; two-pass unstable resonator with rotation of the laser beam aperture about its axis through 1800; the output mirror of the resonator with a variable reflection coefficient; hyperthermal conductive plates for thermal stabilization of the laser diode generation modes. The presence of thermal conductive plates excludes conventional running water systems applied as cooling systems for solid-state laser components. The diodes temperature stabilization is achieved by applying the algorithm of pulse-width modulation of power of auxiliary electric heaters. To compensate for non-stationary thermal distortions of the slab refractive index, the laser resonator scheme comprises a prism reflector with an apex angle of 1200. Narrow sides of the prism are covered with reflective coating, and its wide side is sprayed with antireflection coating. The beam aperture is turned around its axis through 1800 because of triple reflection of the beam inside the prism. The turning procedure leads to compensating for the output beam phase distortions in view of symmetric character of the aberrations of slab refractive index. To suppress parasitic oscillations inside the slab, dielectric coatings of wide sides of the slab are used. Main Results. We have demonstrated theoretically and experimentally that the usage of hyperthermal conductive plates together with the algorithm of pulse-width modulation provides stabilizing of the diode substrate temperature accurate within ± 0.1 °С and smoothing the temperature distribution along the plate surface accurate

  6. Energy performance of a ventilation system for a block of apartments with a ground source heat pump as generation system

    Science.gov (United States)

    Lucchi, M.; Lorenzini, M.; Valdiserri, P.

    2017-01-01

    This work presents a numerical simulation of the annual performance of two different systems: a traditional one composed by a gas boiler-chiller pair and one consisting of a ground source heat pump (GSHP) both coupled to two thermal storage tanks. The systems serve a bloc of flats located in northern Italy and are assessed over a typical weather year, covering both the heating and cooling seasons. The air handling unit (AHU) coupled with the GSHP exhibits excellent characteristics in terms of temperature control, and has high performance parameters (EER and COP), which make conduction costs about 30% lower than those estimated for the traditional plant.

  7. Performance tests of air source heat pumps under frosting conditions. Quality of results

    Science.gov (United States)

    Fahlen, P.

    This report focuses on the analysis of uncertainties in research regarding air-source heat pumps. The principles recommended by the Western European Calibration Conference (WECC) are applied and the generated information is condensed in the form of uncertainty budgets. The ensuring discussion, and the Measurement Assurance Program that was applied during the research work are also relevant to general testing of cooling coils, e.g. for air source heat pumps. The general conclusion of the analysis is that the method of determining frost mass by continuous weighing and frost density by inference from pressure drop considerations, which is presented in the report, has the potential to produce results with an accuracy on a par with the best previously used techniques to investigate frosting and defrosting phenomena. Furthermore, the methodology has the distinct advantage of yielding online measuring possibilities and being much less time consuming than traditional techniques.

  8. Operational performance of the photovoltaic-powered grain mill and water pump at Tangaye, Upper Volta

    Science.gov (United States)

    Martz, J. E.; Ratajczak, A. F.; Delombard, R.

    1982-01-01

    The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well, and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.

  9. THREE-DIMENSIONAL COUPLED IMPELLER-VOLUTE SIMULATION OF FLOW IN CENTRIFUGAL PUMP AND PERFORMANCE PREDICTION

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A three-dimensional turbulent flow through an entire centrifugal pump is simulated using k-ε turbulence model modified by rotation and curvature, SIMPLEC method and body-fitted coordinate. The velocity and pressure fields are obtained for the pump under various working conditions, which is used to predict the head and hydraulic efficiency of the pump, and the results correspond well with the measured values. The calculation results indicate that the pressure is higher on the pressure side than that on the suction side of the blade; The relative velocity on the suction side gradually decreases from the impeller inlet to the outlet, while increases on the pressure side, it finally results in the lower relative velocity on the suction side and the higher one on the pressure side at the impeller outlet; The impeller flow field is asymmetric, i.e. the velocity and pressure fields are totally different among all channels in the impeller; In the volute, the static pressure gradually increases with the flow route, and a large pressure gratitude occurs in the tongue; Secondary flow exists in the rear part of the spiral.

  10. Evaluating Performance of Water Hammer Control Equipment using Hytran Software in Hasanlu Dam Pumping Station

    Directory of Open Access Journals (Sweden)

    Parisa Nazari

    2016-09-01

    Full Text Available Unsteady flows start from a steady state and end the other steady state condition. In water lines unsteady flows occur mainly due to the closure of valves, sudden pumps stops or sudden pumps starts. To prevent these losses, the major ways which can be used are pressure valves, air tanks and surge tanks. All various methods of controlling water hammer pursue a common goal, and that is to balance pressure from water hammer to adjust the pressure in an acceptable range in the network. In this paper, unsteady hydraulic flow control methods include protective measures such as the use of check valve and installation of air valves, air chambers and surge tanks are investigated and compared. And so that the1400 mm existing pipe line of Hasanlu dam pump station, can be simulated using Hytran software, and then minimum and maximum pressure due to the different choking in the throat connecting the main route was evaluated. The results presented that the use of check valve with built-in soft starter in the present case study reduces the positive and negative pressure caused by the water hammer phenomenon as possible value.

  11. Enhancing The National Map Through Tactical Planning and Performance Monitoring

    Science.gov (United States)

    ,

    2008-01-01

    Tactical planning and performance monitoring are initial steps toward improving 'the way The National Map works' and supporting the U.S. Geological Survey (USGS) Science Strategy. This Tactical Performance Planning Summary for The National Map combines information from The National Map 2.0 Tactical Plan and The National Map Performance Milestone Matrix. The National Map 2.0 Tactical Plan is primarily a working document to guide The National Map program's execution, production, and metrics monitoring for fiscal years (FY) 2008 and 2009. The Tactical Plan addresses data, products, and services, as well as supporting and enabling activities. The National Map's 2-year goal for FY 2008 and FY 2009 is to provide a range of geospatial products and services that further the National Spatial Data Infrastructure and underpin USGS science. To do this, the National Geospatial Program will develop a renewed understanding during FY 2008 of key customer needs and requirements, develop the infrastructure to support The National Map business model, modernize its business processes, and reengineer its workforce. Priorities for The National Map will be adjusted if necessary to respond to changes to the project that may impact resources, constrain timeframes, or change customer needs. The supporting and enabling activities that make it possible to produce the products and services of The National Map will include partnership activities, improved compatibility of systems, outreach, and integration of data themes.

  12. Manufacturing of Wearable Sensors for Human Health and Performance Monitoring

    Science.gov (United States)

    Alizadeh, Azar

    2015-03-01

    Continuous monitoring of physiological and biological parameters is expected to improve performance and medical outcomes by assessing overall health status and alerting for life-saving interventions. Continuous monitoring of these parameters requires wearable devices with an appropriate form factor (lightweight, comfortable, low energy consuming and even single-use) to avoid disrupting daily activities thus ensuring operation relevance and user acceptance. Many previous efforts to implement remote and wearable sensors have suffered from high cost and poor performance, as well as low clinical and end-use acceptance. New manufacturing and system level design approaches are needed to make the performance and clinical benefits of these sensors possible while satisfying challenging economic, regulatory, clinical, and user-acceptance criteria. In this talk we will review several recent design and manufacturing efforts aimed at designing and building prototype wearable sensors. We will discuss unique opportunities and challenges provided by additive manufacturing, including 3D printing, to drive innovation through new designs, faster prototyping and manufacturing, distributed networks, and new ecosystems. We will also show alternative hybrid self-assembly based integration techniques for low cost large scale manufacturing of single use wearable devices. Coauthors: Prabhjot Singh and Jeffrey Ashe.

  13. Analysis of vertical flow during ambient and pumped conditions in four monitoring wells at the Pantex Plant, Carson County, Texas, July-September 2008

    Science.gov (United States)

    Stanton, Gregory P.; Thomas, Jonathan V.; Stoval, Jeffery

    2009-01-01

    The Pantex Plant is a U.S. Department of Energy/National Nuclear Security Administration (USDOE/NNSA)-owned, contractor-operated facility managed by Babcock & Wilcox Technical Services Pantex, LLC (B&W Pantex) in Carson County, Texas, approximately 17 miles northeast of Amarillo. The U.S. Geological Survey, in cooperation with B&W Pantex through the USDOE/NNSA, made a series of flowmeter measurements and collected other borehole geophysical logs during July–September 2008 to analyze vertical flow in screened intervals of four selected monitoring wells (PTX01–1012, PTX06–1044, PTX06–1056, and PTX06–1068) at the Pantex Plant. Hydraulic properties (transmissivity values) of the section of High Plains (Ogallala) aquifer penetrated by the wells also were computed. Geophysical data were collected under ambient and pumped flow conditions in the four monitoring wells. Unusually large drawdowns occurred at two monitoring wells (PTX06–1044 and PTX06–1056) while the wells were pumped at relatively low rates. A decision was made to redevelop those wells, and logs were run again after redevelopment in the two monitoring wells.

  14. Mitigation potential of horizontal ground coupled heat pumps for current and future climatic conditions: UK environmental modelling and monitoring studies

    Science.gov (United States)

    García González, Raquel; Verhoef, Anne; Vidale, Pier Luigi; Gan, Guohui; Wu, Yupeng; Hughes, Andrew; Mansour, Majdi; Blyth, Eleanor; Finch, Jon; Main, Bruce

    2010-05-01

    An increased uptake of alternative low or non-CO2 emitting energy sources is one of the key priorities for policy makers to mitigate the effects of environmental change. Relatively little work has been undertaken on the mitigation potential of Ground Coupled Heat Pumps (GCHPs) despite the fact that a GCHP could significantly reduce CO2 emissions from heating systems. It is predicted that under climate change the most probable scenario is for UK temperatures to increase and for winter rainfall to become more abundant; the latter is likely to cause a general rise in groundwater levels. Summer rainfall may reduce considerably, while vegetation type and density may change. Furthermore, recent studies underline the likelihood of an increase in the number of heat waves. Under such a scenario, GCHPs will increasingly be used for cooling as well as heating. These factors will affect long-term performance of horizontal GCHP systems and hence their economic viability and mitigation potential during their life span ( 50 years). The seasonal temperature differences encountered in soil are harnessed by GCHPs to provide heating in the winter and cooling in the summer. The performance of a GCHP system will depend on technical factors (heat exchanger (HE) type, length, depth, and spacing of pipes), but also it will be determined to a large extent by interactions between the below-ground parts of the system and the environment (atmospheric conditions, vegetation and soil characteristics). Depending on the balance between extraction and rejection of heat from and to the ground, the soil temperature in the neighbourhood of the HE may fall or rise. The GROMIT project (GROund coupled heat pumps MITigation potential), funded by the Natural Environment Research Council (UK), is a multi-disciplinary research project, in collaboration with EarthEnergy Ltd., which aims to quantify the CO2 mitigation potential of horizontal GCHPs. It considers changing environmental conditions and combines

  15. Evaluation of Green Buildings’ Overall Performance through in Situ Monitoring and Simulations

    Directory of Open Access Journals (Sweden)

    Francesco Asdrubali

    2013-12-01

    Full Text Available The evaluation of the overall performance of a green building is complex, since many construction, energy and environmental aspects have to be considered. The Umbria Region in Italy, through various public tenders, recently funded several residential buildings, innovative in terms of construction quality, green technologies and sustainable solutions, such as natural building materials, integrated sunspaces, PV (photovoltaic modules and solar collectors, geothermal heat pumps, that had to be adopted to obtain the public contribution. The University of Perugia carried out an extended monitoring of these buildings, in order to verify the actual achievement of design objectives, to certify the real savings in terms of energy and environmental loads and to assess the indoor comfort conditions for occupants. In situ thermal, acoustical and lighting measurements were carried out for more than one year. Energy simulations were performed by means of codes which implement the algorithms required by the Italian Law. Moreover, a comparison between real consumptions and simulated energy requirements was carried out. Finally, the buildings were characterized from the environmental sustainability point of view, using the method adopted by the Umbria Region. This assessment was borrowed from ITACA (Institute for Innovation and Transparency in Government Procurement and Environmental Compatibility procedure [an Italian procedure similar to Leadership in Energy and Environmental Design (LEED] and consists of 20 worksheets, one for each different performance indicator, at the aim of carefully describing the environmental quality of the building.

  16. APD performance in a luminosity monitor at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Bartolome, E.; Boix, G. E-mail: gaelle.boix@cern.ch; Casado, M.P.; Chmeissani, M.; Clemente, S.; Fernandez, E.; Garrido, L.; Lorenz, E.; Martinez, M.; Merino, G.; Riu, I.; Sanchez, F.; Wright, A

    2000-03-11

    Avalanche Photo-Diodes (APDs) are being used as optical readout elements in a sampling electromagnetic calorimeter made of alternate layers of tungsten and plastic scintillators. The calorimeter serves as a small-angle luminosity monitor in the stray magnetic field of the ALEPH detector at LEP (CERN). Its scintillators are coupled both to APDs and conventional PMTs simultaneously via wavelength shifter fibres. In this paper we present results on the overall performance of the APDs, including gain and stability versus time and energy, based on the direct comparison of the two photosensitive devices.

  17. APD performance in a luminosity monitor at LEP

    Science.gov (United States)

    Bartolomé, E.; Boix, G.; Casado, M. P.; Chmeissani, M.; Clemente, S.; Fernández, E.; Garrido, L.; Lorenz, E.; Martínez, M.; Merino, G.; Riu, I.; Sánchez, F.; Wright, A.

    2000-03-01

    Avalanche Photo-Diodes (APDs) are being used as optical readout elements in a sampling electromagnetic calorimeter made of alternate layers of tungsten and plastic scintillators. The calorimeter serves as a small-angle luminosity monitor in the stray magnetic field of the ALEPH detector at LEP (CERN). Its scintillators are coupled both to APDs and conventional PMTs simultaneously via wavelength shifter fibres. In this paper we present results on the overall performance of the APDs, including gain and stability versus time and energy, based on the direct comparison of the two photosensitive devices.

  18. APD performance in a luminosity monitor at LEP

    CERN Document Server

    Bartolomé, E; Casado, M P; Chmeissani, M; Clemente, S; Fernández, E; Garrido, L; Lorenz, E; Martínez, M; Merino, G; Riu, I; Sánchez, F; Wright, A

    2000-01-01

    Avalanche photo-diodes (APDs) are being used as optical readout elements in a sampling electromagnetic calorimeter made of alternate layers of tungsten and plastic scintillators. The calorimeter serves as a small-angle luminosity monitor in the stray magnetic field of the ALEPH detector at LEP (CERN). Its scintillators are coupled both to APDs and conventional PMTs simultaneously via wavelength shifter fibres. In this paper we present results on the overall performance of the APDs, including gain and stability versus time and energy, based on the direct comparison of the two photosensitive devices. (6 refs).

  19. Evaluation of Activity Recognition Algorithms for Employee Performance Monitoring

    Directory of Open Access Journals (Sweden)

    Mehreen Mumtaz

    2012-09-01

    Full Text Available Successful Human Resource Management plays a key role in success of any organization. Traditionally, human resource managers rely on various information technology solutions such as Payroll and Work Time Systems incorporating RFID and biometric technologies. This research evaluates activity recognition algorithms for employee performance monitoring. An activity recognition algorithm has been implemented that categorized the activity of employee into following in to classes: job activities and non-job related activities. Finally, the algorithm will compute the time which employee spent in job related and non-job related activities. This paper presents a novel architecture based upon video analytics that can facilitate Human Resource Managers in real time.

  20. YUCSA: A CLIPS expert database system to monitor academic performance

    Science.gov (United States)

    Toptsis, Anestis A.; Ho, Frankie; Leindekar, Milton; Foon, Debra Low; Carbonaro, Mike

    1991-01-01

    The York University CLIPS Student Administrator (YUCSA), an expert database system implemented in C Language Integrated Processing System (CLIPS), for monitoring the academic performance of undergraduate students at York University, is discussed. The expert system component in the system has already been implemented for two major departments, and it is under testing and enhancement for more departments. Also, more elaborate user interfaces are under development. We describe the design and implementation of the system, problems encountered, and immediate future plans. The system has excellent maintainability and it is very efficient, taking less than one minute to complete an assessment of one student.

  1. Jet pump noise analysis for BWRs

    Energy Technology Data Exchange (ETDEWEB)

    Castillo-Duran, R.; Hernandez-lopez, H.; Ortiz-Villafuerte, J.; Alonso-Vargas, G. [Instituto Nacional de Investigaciones Nucleares, Mexico (Mexico); Calleros-Micheland, G. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Veracruz (Mexico)

    2004-07-01

    The use of noise analysis for detection of BWR component malfunction is a powerful tool in determining abnormal operation conditions, during the life of a nuclear power plant. Since the eighties, several nuclear reactors have reported problems related with jet pumps and recirculation loops. The NRC (Nuclear Regulatory Commission) recommends performing periodic monitoring to individual pressure drop jet pumps, to prevent structural failure. In this work, noise analysis methods are used for detection of jet pumps abnormal operation conditions in a BWR. Power signals obtained from the backup process computer of a BWR are analyzed with a home-developed software, called NOISE, for noise diagnostic of power signals. The computer program takes individual signals from the tabular report of the process computer. The normalized power spectral density (NPSD) is then obtained, using a Prime Factor Algorithm to calculate the Fast Fourier Transform. The NPSD of the jet pumps pressure drop, of Unit 2 of the Laguna Verde Nuclear Power Plant, showed a noticeable change in jet pump 6 during 2003, considering the period from the startup test to operation during 2003. This abnormal condition was due to that the jet pump throat was partially blocked. The noise analysis methodology is shown to be a useful tool for malfunction detection, and could be applied to create a data bank for monitoring the dynamic behavior of BWR jet pumps. (authors)

  2. Performance prediction between horizontal and vertical source heat pump systems for greenhouse heating with the use of artificial neural networks

    Science.gov (United States)

    Benli, Hüseyin

    2016-08-01

    This paper presents the suitability of artificial neural networks (ANNs) to predict the performance and comparison between a horizontal and a vertical ground source heat pump system. Performance forecasting is the precondition for the optimal control and energy saving operation of heat pump systems. In this study, performance parameters such as air temperature entering condenser fan-coil unit, air temperature leaving condenser fan-coil unit, and ground temperatures (2 and 60 m) obtained experimental studies are input data; coefficient of performance of system (COPsys) is in output layer. The back propagation learning algorithm with three different variants such as Levenberg-Marguardt, Pola-Ribiere conjugate gradient, and scaled conjugate gradient, and also tangent sigmoid transfer function were used in the network so that the best approach can be found. The results showed that LM with three neurons in the hidden layer is the most suitable algorithm with maximum correlation coefficients R2 of 0.999, minimum root mean square RMS value and low coefficient variance COV. The reported results confirmed that the use of ANN for performance prediction of COPsys,H-V is acceptable in these studies.

  3. Improved effectiveness of performance monitoring in amateur instrumental musicians.

    Science.gov (United States)

    Jentzsch, Ines; Mkrtchian, Anahit; Kansal, Nayantara

    2014-01-01

    Here we report a cross-sectional study investigating the influence of instrumental music practice on the ability to monitor for and respond to processing conflicts and performance errors. Behavioural and electrophysiological indicators of response monitoring in amateur musicians with various skill levels were collected using simple conflict tasks. The results show that instrumental musicians are better able than non-musicians to detect conflicts and errors as indicated by systematic increases in the amplitude of the error-related negativity and the N200 with increasing levels of instrumental practice. Also, high levels of musical training were associated with more efficient and less reactive responses after experience of conflicts and errors as indicated by reduced post-error interference and post-conflict processing adjustments. Together, the present findings suggest that playing a musical instrument might improve the ability to monitor our behavior and adjust our responses effectively when needed. As these processes are amongst the first to be affected by cognitive aging, our evidence could promote musical activity as a realistic intervention to slow or even prevent age-related decline in frontal cortex mediated executive functioning. © 2013 Published by Elsevier Ltd.

  4. Monitoring and analyzing features of electrical power quality system performance

    Directory of Open Access Journals (Sweden)

    Genci Sharko

    2010-06-01

    Full Text Available Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many more causes of such poor quality power. Power quality of power systems, which affects all connected electrical and electronic equipment, is a measure of deviations in voltages, currents, frequency, temperatures, winding forces and torques of particular supply systems and their components. In recent years, a considerable increase in nonlinear loads has been experienced; in particular distributed loads, such as computers, monitors and lighting, and distributed sources. The aim of this paper is to display a way of monitoring and analyzing features of electrical power quality system. As a monitoring example is taken output from power transformer rated at 320 kVA, part of distribution grid of Durres City in Albania.

  5. A Study on the Efficiency Improvement of Multi-Geothermal Heat Pump Systems in Korea Using Coefficient of Performance

    Directory of Open Access Journals (Sweden)

    Young-Ju Jung

    2016-05-01

    Full Text Available The Korean government is fostering a renewable energy industry as a means of handling the energy crisis. Among the renewable energy systems available, geothermal energy has been highlighted as highly efficient, safely operable and relatively unaffected by outdoors air conditions. Despite the increasing use of renewable energy, the devices using renewables may not be operating appropriately. This study examined current problems in the operation of a geothermal heat pump (GHP system. The efficiency of a geothermal heat pump system to studied to maximize the operation plan. Our study modelled the target building and analyzed the energy using TRNSYS, which is a dynamic energy simulation tool, to apply the coefficient of performance (COP and evaluate the operation method. As a result, the GHP total energy consumption from the COP control method was reduced by 46% compared to the current operation. The proposed control method was evaluated after applying the system to a building. The results showed that efficient operation of a geothermal heat pump system is possible.

  6. Research on Three-Dimensional Unsteady Turbulent Flow in Multistage Centrifugal Pump and Performance Prediction Based on CFD

    Directory of Open Access Journals (Sweden)

    Zhi-jian Wang

    2013-01-01

    Full Text Available The three-dimensional flow physical model of any stage of the 20BZ4 multistage centrifugal pump is built which includes inlet region, impeller flow region, guide-vane flow region and exit region. The three-dimensional unsteady turbulent flow numerical model is created based on Navier-Stoke solver and standard k-ε turbulent equations. The method of multireference frame (MRF and SIMPLE algorithm are used to simulate the flow in multistage centrifugal pump based on FLUENT software. The distributions of relative velocity, absolute velocity, static pressure, and total pressure in guide vanes and impellers under design condition are analyzed. The simulation results show that the flow in impeller is mostly uniform, without eddy, backflow, and separation flow, and jet-wake phenomenon appears only along individual blades. There is secondary flow at blade end and exit of guide vane. Due to the different blade numbers of guide vane and impeller, the total pressure distribution is asymmetric. This paper also simulates the flow under different working conditions to predict the hydraulic performances of centrifugal pump and external characteristics including flow-lift, flow-shaft power, and flow-efficiency are attained. The simulation results are compared with the experimental results, and because of the mechanical losses and volume loss ignored, there is a little difference between them.

  7. Methodology to monitor and diagnostic vibrations of the motor-pumps used in the primary cooling system of IEAR-1 nuclear research reactor; Metodologia para monitoracao e diagnostico de vibracao das bombas moto-operadas do circuito primario de refrigeracao do Reator IEA-R1

    Energy Technology Data Exchange (ETDEWEB)

    Benevenuti, Erion de Lima

    2004-07-01

    The objectives of this study are to establish a strategy to monitor and diagnose vibrations of the motor pumps used in the primary reactor cooling system of the IEA-R1 nuclear research reactor, to verify the possibility of using the existing installed monitoring vibration system and to implement such strategy in a continuous way. Four types of mechanical problems were considered: unbalancing, misalignment, gaps and faults in bearings. An adequate set of analysis tools, well established by the industry, was selected. These are: global measurements of vibration, velocity spectrum and acceleration envelope spectrum. Three sources of data and information were used; the data measured from the primary pumps, experimental results obtained with a Spectra Quest machine used to simulate mechanical defects and data from the literature. The results show that, for the specific case of the motor-pumps of IEA-R1 nuclear research reactor, although the technique using the envelope of acceleration, which is not available in the current system used to monitor the vibration of the motor pumps, is the one with best performance, the other techniques available in the system are sufficient to monitor the four types of mechanical problems mentioned. The proposed strategy is shown and detailed in this work. (author)

  8. Design of Computer Monitoring and Protection System for Gaotankou Pump Station%高潭口泵站计算机监控保护系统设计

    Institute of Scientific and Technical Information of China (English)

    张兰芳

    2011-01-01

    简述高潭口泵站的概况及计算机监控保护设计的主要原则,给出了系统的总体设计方案,并以主机保护为例着重介绍了泵站微机保护系统特点。该保护系统设计安全、可靠、方便、实用。%This paper briefly presents Gaotankou Pump Station and its major design principle on computer monitoring and protection system, gives overall design scheme of the system, and introduces the characterization of the micro computer protection system in pump station by taking mainframe protection as an example. The protection systems designed are safety, reliable, convenient and practical.

  9. Performance Evaluation of Industrial Hygiene Air Monitoring Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Maughan, A D.; Glissmeyer, John A.; Birnbaum, Jerome C.

    2004-12-10

    Tests were performed to evaluate the accuracy, precision and response time of certain commercially available handheld toxic gas monitors. The tests were conducted by PNNL in the Chemical Chamber Test Facility for CH2MHill Hanford Company. The instruments were tested with a set of dilute test gases including ammonia, nitrous oxide, and a mixture of organic vapors (acetone, benzene, ethanol, hexane, toluene and xylene). The certified gases were diluted to concentrations that may be encountered in the outdoor environment above the underground tank farms containing radioactive waste at the U.S. Department of Energy's Hanford site, near Richland, Washington. The challenge concentrations are near the lower limits of instrument sensitivity and response time. The performance test simulations were designed to look at how the instruments respond to changes in test gas concentrations that are similar to field conditions.

  10. Design of Ground Source Heat Pump Monitoring System Based on MCGS%基于MCGS的地源热泵监控系统的设计

    Institute of Scientific and Technical Information of China (English)

    商家伟; 苏华

    2016-01-01

    A monitoring system is developed for a ground source heat pump system in Chengdu. Equipments are controlled by PLC and monitoring data is transported from PLC to PC. The host PC moni-toring system is developed by MCGS whose functions cover controlling, operation status displaying, data logging and displaying and alarming.%针对成都某别墅地源热泵系统,设计了一个监控系统方案。利用PLC控制空调设备、监测并上传现场数据给上位机。利用MCGS开发上位机监控系统。该监控系统包含设备控制、状态显示、参数采集及显示、报警等功能。

  11. Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection.

    Science.gov (United States)

    Ashizawa, Hiroaki; Ohara, Shinobu; Yamaguchi, Shigeru; Takahashi, Masao; Endo, Masamori; Nanri, Kenzo; Fujioka, Tomoo; Tittel, Frank K

    2003-03-01

    A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.

  12. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  13. Performance Analysis of Solar Assisted Fluidized Bed Dryer Integrated Biomass Furnace with and without Heat Pump for Drying of Paddy

    OpenAIRE

    M. Yahya

    2016-01-01

    The performances of a solar assisted fluidized bed dryer integrated biomass furnace (SA-FBDIBF) and a solar assisted heat pump fluidized bed dryer integrated biomass furnace (SAHP-FBDIBF) for drying of paddy have been evaluated, and also drying kinetics of paddy were determined. The SA-FBDIBF and the SAHP-FBDIBF were used to dry paddy from 11 kg with moisture content of 32.85% db to moisture content of 16.29% db (14% wb) under an air mass flow rate of 0.1037 kg/s within 29.73 minutes and 22.9...

  14. Design and Performance Evaluation of a Solar Assisted Heat Pump Dryer Integrated with Biomass Furnace for Red Chilli

    OpenAIRE

    M. Yahya

    2016-01-01

    The performance of a solar assisted heat pump dryer integrated with biomass furnace has been designed and evaluated for drying red chillies, and drying kinetics of red chillies were evaluated. The red chillies were dried from 22 kg with moisture content of 4.26 db to moisture content of 0.08 db which needed 11 hours, with the average drying chamber temperature, drying chamber relative humidity, and an air mass flow rate of 70.5°C, 10.1%, and 0.124 kg/s, respectively, while the open sun drying...

  15. Experimental and performance study of the compact solar absorption air-conditioner system with thermosiphon solution elevation pump

    Energy Technology Data Exchange (ETDEWEB)

    Cong Lin; Zheng Hongfei; Tao Tao [Beijing Inst. of Tech., BJ (China); Li Zhengliang [Guangxi Teacher Coll., Nanning, GX (China)

    2008-07-01

    A new type LiBr adsorption solar air-condition system with thermosiphon solution elevation pump is designed, whose evaporator and absorption tanks are combined in a circularity, which makes the chill part very compact. On the basis of theoretical arithmetic, the comprehensive heat transfer coefficient on the evaporator side and the theoretical refrigerating capacity are got theoretically. By experimental study, some useful performance curves are got, which is significant for optimal design and improvement. The refrigerating capacity of the system can be got to be 2.14kW. (orig.)

  16. 泵及泵用作透平时的数值模拟与外特性实验%Numerical Simulation and Performance Experiment on Pump and Pump as Turbine

    Institute of Scientific and Technical Information of China (English)

    杨孙圣; 孔繁余; 宿向辉; 陈浩

    2012-01-01

    An open pump as turbine (PAT) test rig was built to examine the relations between pump and PAT performance characteristics, and its two models' internal flow field. The experiment on a single stage centrifugal pump was conducted to study its performance characteristics under normal and reverse operating conditions. The results show that the reverse operating centrifugal pump has high efficiency. The numerical simulation on the pump and the PAT was performed by adopting all domain and structural mesh technique, and the simulation results are in reasonable consistency with the experimental data. Additionally the analyses were performed on the pressure field and the velocity field inside the pump and the PAT.%针对泵及泵用作透平时的内部流动规律等问题展开了研究,并建立了一种开式泵用作透平时的实验台,同时对一单级单吸离心泵的正反工况进行了外特性实验研究,从而得到了相应比转速的泵在正反工况下的外特性曲线,进而验证了泵在反运转时可用作透平且具有较高的效率.采用全流场和结构化网格技术对泵及泵用作透平时进行了数值计算,计算结果与实验结果吻合良好;对泵及泵用作透平时的内部速度场和压力场进行了分析.

  17. Effect of Centrifugal Pump Blade Inlet Geometry on Pump Cavitation Performance%离心泵的叶片进口几何形状对泵汽蚀性能的影响

    Institute of Scientific and Technical Information of China (English)

    张建华; 楚武利; 马文瑛

    2012-01-01

    为了改善离心泵内的汽蚀性能,以ZA150 -315石油化工离心泵为研究对象,在离心叶轮基本外尺寸和设计转速相同的情况下,以3种不同厚度变化规律构造3种离心泵叶轮,运用FLUENT软件进行数值模拟计算,得到了汽蚀发生时泵内部气-液两相分布规律和压力分布规律.分析表明:叶片进口段的形状影响泵的汽蚀性能.叶片进口段形状越接近流线型泵的抗汽蚀性能越好,加大叶片进口段曲率半径可以降低泵的汽蚀余量,改善泵的汽蚀性能.%In order to improve centrifugal pump cavitation performance, ZA150 - 315 petrochemical centrifugal pump were studied. With the basic exterior parameters and rotational speed of centrifugal impeller were fixed, centrifugal impellers were generated with three different changes of thickness, the vapor - liquid two - phase distribution and pressure distribution of centrifugal impeller inner flow were obtained by using computer fluid dynamic method. Analysis of simulated results demonstrate that, the blade inlet geometry have effect on pump cavitation performance. The geometry of the blade inlet closer to streamline, the better to the pump anti - cavitation performance, increasing the radius of curvature of the blade inlet section can reduce the pump cavitation allowance, improving pump cavitation performance.

  18. Practical tests for monitoring performance, fatigue and recovery in triathletes.

    Science.gov (United States)

    Coutts, Aaron J; Slattery, Katie M; Wallace, Lee K

    2007-12-01

    Few studies have described simple tests which can be used to provide an early warning of overreaching. The purpose of this study was to examine selected practical tests for monitoring changes in performance, fatigue and recovery of endurance athletes. Sixteen male triathletes were randomly assigned into matched groups. The normal training (NT) and intensified training (IT) groups completed 4 weeks of training followed by a 2-week taper. Physiological measures were taken pre- and post-overload and post-taper periods during an incremental treadmill test to exhaustion. Performance was assessed weekly using a 3-km run time trial (3 kmTT). Five-bound jump for distance (5BT) and submaximal running heart rate (HR(submax)) test were measured twice weekly and the Daily Analyses of Life Demands for Athletes (DALDA) were recorded. During the overload training period, the IT group completed approximately 290% more training load than the NT group (ptaper, the IT group improved 3 kmTT. In contrast, the performance, physiological and psychological markers of NT group remained relatively unchanged throughout the 6-week training period. There were weak significant correlations between weekly changes in 3 kmTT and 5BT (r=-0.37, p<0.01). The DALDA and 5BT may be practical tests for assessing changes in performance, fatigue and recovery of endurance athletes.

  19. 1997 Performance Testing of Multi-Metal Continuous Emissions Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Sky +, Inc.

    1998-09-01

    Five prototype and two commercially available multi-metals continuous emissions monitors (CEMs) were tested in September 1997 at the Rotary Kiln Incinerator Simulator facility at the EPA National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The seven CEMs were tested side by side in a long section of duct following the secondary combustion chamber of the RKIS. Two different concentrations of six toxic metals were introduced into the incinerator-approximately 15 and 75 µg/dscm of arsenic, beryllium, cadmium, chromium, lead, and mercury (We also tested for antimony but we are not reporting on it here because EPA recently dropped antimony from the list of metals addressed by the draft MACT rule). These concentrations were chosen to be close to emission standards in the draft MACT rule and the estimated Method Detection Limit (MDL) required of a CEM for regulatory compliance purposes. Results from this test show that no CEMs currently meet the performance specifications in the EPA draft MACT rule for hazardous waste incinerators. Only one of the CEMs tested was able to measure all six metals at the concentrations tested. Even so, the relative accuracy of this CEM varied between 35% and 100%, not 20% or less as required in the EPA performance specification. As a result, we conclude that no CEM is ready for long-term performance validation for compliance monitoring applications. Because sampling and measuring Hg is a recurring problem for multi-metal CEMs as well as Hg CEMs, we recommended that developers participate in a 1998 DOE-sponsored workshop to solve these and other common CEM measurement issues.

  20. Effect of the magnet insertion on the performance of a superconducting pump

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M., E-mail: mb12021@shibaura-it.ac.jp [Shibaura institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo 135-8548 (Japan); Inoue, K.; Koshizuka, N. [Shibaura institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo 135-8548 (Japan); Seki, H. [Awaji Materia, Kanda ogawacho 2-3-13, Chiyoda-ku, Tokyo 101-0045 (Japan); Murakami, M. [Shibaura institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo 135-8548 (Japan); Hiragushi, M. [Seikow Chemical Engineering and Machinery Ltd., Mizudocho 4-1-31, Amagasaki, Hyogo 661-0026 (Japan); Akiyama, S. [MAG-NEO, Suwa 1-4-23, Saitama Iwatsuki-ku, Saitama 339-0007 (Japan)

    2014-09-15

    Highlights: • Non-contact rotation is possible by using permanent magnets and superconductors. • It is necessary to rotate a superconducting pump stably for practical applications. • We placed a permanent magnet at the bottom to increase the stiffness. • Inserting permanent magnets was effective in increasing the rotational stability. - Abstract: For medical and semiconductor fabrication lines, an ultra-clean and impurity-free environment is often required. In order to realize such a contaminant-free environment, it is desirable to employ a completely non-contact rotating mechanism. Such a non-contact rotation is possible by using a combination of permanent magnets and bulk superconductors. Furthermore, it is necessary to rotate a superconducting pump stably for practical applications. With the aim of increasing the stiffness of rotational parts, we placed a permanent magnet at the bottom such that the superconductors are sandwiched by top and bottom magnets. It was confirmed that the stiffness could surely be improved by arranging lower permanent magnets.

  1. Performance evaluation of the PITBULL{trademark} pump for the removal of hazardous waste

    Energy Technology Data Exchange (ETDEWEB)

    Hatchell, B.K.; Combs, W.H.; Hymas, C.R.; Powell, M.R.; Rinker, M.W.; White, M.

    1998-09-01

    One objective of the Waste Removal Project at the Department of Energy`s Savannah River Site (SRS) is to explore methods to successfully remove waste heels that will remain in the high-level waste tanks after bulk waste removal has been completed. Tank closure is not possible unless this residue is removed. As much as 151,000 liters of residue can remain after a conventional waste removal campaign. The waste heels can be comprised of sludge, zeolite, and silica. The heels are generally hardened or compacted insoluble particulate with relatively rapid settling velocities. A PITBULL{trademark} pump is being considered by SRS to retrieve sludge-type waste from Tank 19. Sections 1 through 4 of this report present the scope and objectives of the test program, describe the principles of operation of the PITBULL, and present the test approach, set-up, and instrumentation. Test results, including pumping rates with water and slurry, are provided in Section 5, along with considerations for remote operation. Conclusions and recommendations are provided in Section 6.

  2. Performance in cooling mode of a heat pump using panels with PV cells as the condenser; Taiyo denchitsuki panel wo gyoshukuki to shita heat pump no reibo unten

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, T.; Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan); Fujita, M. [Chubu Electric Power Co. Inc., Nagoya (Japan)

    1996-10-27

    Comparison was made between heat pumps in cooling operation, one having two panels provided with solar cells, the second having an air-cooled heat exchanger alone, and the third having a series connection of a panel unit and air-cooled heat exchanger, all serving as condenser. The results are shown below. In the case of two-panel-unit condenser, there is a difference ({Delta}t) of 15{degree}C between the daytime free air temperature and condensing temperature but, with decreased insolation, free air temperature, and wind speed in the evening, the {Delta}t lowered to approximately 8{degree}C while the COP (coefficient of performance) increased from 2.4 to 3.3. On a cloudy day in summer, the two-panel-unit condenser had a {Delta}t of 13.9{degree}C and a COP of 3.1. In the case of the series-connection condenser, the {Delta}t was approximately 8{degree}C and the COP was 3.5. The COP of the two-panel-unit condenser was lower than that of the air-cooled heat exchanger by 9% at an insolation of 442W/m{sup 2} but it rose to 12% in the absence of insolation. The COP of the two-panel-unit condenser was higher than that of a one-panel-unit condenser by 17%. When an insulator plate was attached to the back of a panel, the {Delta}t increased but the COP decreased by 14%. In the case of the series-connection condenser, the COP increased by 6% in the absence of the insulator plate. 2 refs., 9 figs.

  3. 离心输油泵性能换算的简捷计算方法%Short Way to Converse Performance of Centrifugal Pumps

    Institute of Scientific and Technical Information of China (English)

    孙伟; 汪玉春

    2009-01-01

    以离心泵特性曲线换算图为原始数据,建立了离心输油泵性能换算数学模型.采用Levenberg-Marquardt法优化了数学模型,将泵效率换算系数准确描述为与流量、扬程、原油粘度的非线性函数关系.在建模基础上,利用计算机程序设计建立了离心输油泵性能自动换算系统,该系统能够简捷、准确地优化泵机组设计或运行方案,实现泵性能的自动化换算.%Taking the characteristic curve conversion diagram of centrifugal pump as an original data,a mathematical model for characteristic conversion of centrifugal pumps is set up.Levenberg-Marquardt method is used to optimize the model and the conversion coefficient of pump efficiency is described as a non-linear function with flowrate,pump discharge head and oil viscosity.On the basis of model,performance automatic conversion system for centrifugal pump is established by program design of computer system.A calculation example shows that this system can shortly and accurately optimize the design or operation scenario for pump sets and realize performance automatic conversion for centrifugal pumps.

  4. Biomass Performance : Monitoring and Control in Pharmaceutical Production

    OpenAIRE

    Neeleman, R.

    2002-01-01

    The primary concern in the pharmaceutical industry is not the optimisation of product yield or the reduction of manufacturing cost, but the production of a product of consistently high quality. This has resulted in 'process monitoring' becoming an integral part of process operation. In this thesis process monitoring is one of the central themes, from monitoring the environment of the micro-organisms to monitoring the micro-organisms themselves. The latter is called monitoring biomass performa...

  5. Exercise hemodynamics during extended continuous flow left ventricular assist device support: the response of systemic cardiovascular parameters and pump performance.

    Science.gov (United States)

    Martina, Jerson; de Jonge, Nicolaas; Rutten, Marcel; Kirkels, J Hans; Klöpping, Corinne; Rodermans, Ben; Sukkel, Eveline; Hulstein, Nelienke; Mol, Bas; Lahpor, Jaap

    2013-09-01

    Patients on continuous flow left ventricular assist devices (cf-LVADs) are able to return to an active lifestyle and perform all sorts of physical activities. This study aims to evaluate exercise hemodynamics in patients with a HeartMate II cf-LVAD (HM II). Thirty (30) patients underwent a bicycle exercise test. Along with exercise capacity, systemic cardiovascular responses and pump performance were evaluated at 6 and 12 months after HM II implantation. From rest to maximum exercise, heart rate increased from 87 ± 14 to 140 ± 32 beats/minute (bpm) (P<0.01), while systolic arterial blood pressure increased from 93 ± 12 to 116 ± 21 mm Hg (P<0.01). Total cardiac output (TCO) increased from 4.1 ± 1.1 to 8.5 ± 2.8 L/min (P<0.01) while pump flow increased less, from 5.1 ± 0.7 to 6.4 ± 0.6 L/min (P<0.01). Systemic vascular resistance (SVR) decreased from 1776 ± 750 to 1013 ± 83 dynes.s/cm(5) (P<0.001) and showed the strongest correlation with TCO (r= -0.72; P<0.01). Exercise capacity was affected by older age, while blood pressure increased significantly in men compared with women. Exercise capacity remained consistent at 6 and 12 months after HM II implantation, 51% ± 13% and 52% ± 13% of predicted VO2 max for normal subjects corrected for age and gender. In conclusion, pump flow of the HM II may contribute partially to TCO during exercise, while SVR was the strongest determinant of TCO.

  6. Performance of a reentrant cavity beam position monitor

    Directory of Open Access Journals (Sweden)

    Claire Simon

    2008-08-01

    Full Text Available The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs. In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryomodule, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10  μm and has the possibility to perform bunch to bunch measurements for the x-ray free electron laser (X-FEL and the International Linear Collider (ILC. Its other features are a small size of the rf cavity, a large aperture (78 mm, and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH, at Deutsches Elektronen-Synchrotron (DESY and demonstrated its operation at cryogenic temperature inside a cryomodule. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4  μm over a dynamic range ±5  mm in single bunch.

  7. Performance of a reentrant cavity beam position monitor

    Energy Technology Data Exchange (ETDEWEB)

    Simon, C.; Luong, M.; Chel, S.; Napoly, O.; Novo, J.; Roudier, D. [CEA Saclay, DSM, Irfu, SACM, F-91191 Gif Sur Yvette, (France); Rouviere, N. [CNRS, IN2P3-IPN, F-91406 Orsay, (France); Baboi, N.; Mildner, N.; Nolle, D. [DESY, D-22603 Hamburg, (Germany)

    2008-07-01

    The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryo-module, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10 {mu}m and has the possibility to perform bunch to bunch measurements for the X-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryo-module. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4 {mu}m over a dynamic range {+-} 5 mm in single bunch. (authors)

  8. Performance Analysis of WDM-PON System Based on Optimized Remotely Pumped Erbium-Doped Fiber Amplifier (EDFA) Parameter

    Science.gov (United States)

    Ahmed, N.; Fadhil, Hilal A.; Aljunid, S. A.; Sharafat Ali, Md.; Rahman, Matiur

    2015-06-01

    In this paper, the performance of wavelength division multiplexing-passive optical network (WDM-PON) system using the erbium-doped fiber amplifier (EDFA) is optimized and evaluated. The optimization is analyzed by finding the EDFA length range at which the output power produced are the highest and the pump power range at which the gain flatness produced are within the effective range (0.3 dB). After the optimization process, the optimized EDFA system produces the gain of 26.6±0.292 dB, noise figure of 3.82 dB and output power of 7 dBm and the system is then implemented into WDM system. The performance of WDM system is compared against the system without EDFA in terms of bit error rate (BER). Results obtained prove that the proposed system with the EDFA consistently performs better than the conventional system.

  9. Study on Driving Performance of the Axial-Flow Blood Pump under the Condition of Large Gap

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2017-01-01

    Full Text Available The paper demonstrates an improvement of the simulation and computational methods for research on the system magnetic field and driving performance of the large gap magnetic drive system, which is used to drive the axial flow blood pump. The operational principle and structure of large gap magnetic drive system are narrated. Ansoft is adopted to simulate a three-dimensional driving torque to improve accuracy of computation. Experiments and theoretical study show that the use of Z10-T25 oriented silicon steel sheets as the electromagnetic core material can remarkably improve the system driving performance as well as optimize the volume and weight of the electromagnets. So the electromagnet made with oriented silicon steel sheets is conducive to improving the driving performance.

  10. Operational Performance Analysis of Passive Acoustic Monitoring for Killer Whales

    Energy Technology Data Exchange (ETDEWEB)

    Matzner, Shari; Fu, Tao; Ren, Huiying; Deng, Zhiqun; Sun, Yannan; Carlson, Thomas J.

    2011-09-30

    For the planned tidal turbine site in Puget Sound, WA, the main concern is to protect Southern Resident Killer Whales (SRKW) due to their Endangered Species Act status. A passive acoustic monitoring system is proposed because the whales emit vocalizations that can be detected by a passive system. The algorithm for detection is implemented in two stages. The first stage is an energy detector designed to detect candidate signals. The second stage is a spectral classifier that is designed to reduce false alarms. The evaluation presented here of the detection algorithm incorporates behavioral models of the species of interest, environmental models of noise levels and potential false alarm sources to provide a realistic characterization of expected operational performance.

  11. Passive and Active Monitoring on a High Performance Research Network.

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, Warren

    2001-05-01

    The bold network challenges described in ''Internet End-to-end Performance Monitoring for the High Energy and Nuclear Physics Community'' presented at PAM 2000 have been tackled by the intrepid administrators and engineers providing the network services. After less than a year, the BaBar collaboration has collected almost 100 million particle collision events in a database approaching 165TB (Tera=10{sup 12}). Around 20TB has been exported via the Internet to the BaBar regional center at IN2P3 in Lyon, France, for processing and around 40 TB of simulated events have been imported to SLAC from Lawrence Livermore National Laboratory (LLNL). An unforseen challenge has arisen due to recent events and highlighted security concerns at DoE funded labs. New rules and regulations suggest it is only a matter of time before many active performance measurements may not be possible between many sites. Yet, at the same time, the importance of understanding every aspect of the network and eradicating packet loss for high throughput data transfers has become apparent. Work at SLAC to employ passive monitoring using netflow and OC3MON is underway and techniques to supplement and possibly replace the active measurements are being considered. This paper will detail the special needs and traffic characterization of a remarkable research project, and how the networking hurdles have been resolved (or not!) to achieve the required high data throughput. Results from active and passive measurements will be compared, and methods for achieving high throughput and the effect on the network will be assessed along with tools that directly measure throughput and applications used to actually transfer data.

  12. Design and Performance Evaluation of a Solar Assisted Heat Pump Dryer Integrated with Biomass Furnace for Red Chilli

    Directory of Open Access Journals (Sweden)

    M. Yahya

    2016-01-01

    Full Text Available The performance of a solar assisted heat pump dryer integrated with biomass furnace has been designed and evaluated for drying red chillies, and drying kinetics of red chillies were evaluated. The red chillies were dried from 22 kg with moisture content of 4.26 db to moisture content of 0.08 db which needed 11 hours, with the average drying chamber temperature, drying chamber relative humidity, and an air mass flow rate of 70.5°C, 10.1%, and 0.124 kg/s, respectively, while the open sun drying needed 62 hours. Compared to open sun drying, this dryer yielded 82% saving in drying time. The drying rate, the specific moisture extraction rate, and thermal efficiency of the dryer were estimated in average to be about 1.57 kg/h, 0.14 kg/kWh, and 9.03%, respectively. Three mathematical models, the Newton, Henderson-Pabis, and Page models, were fitted to the experimental data on red chillies dried by solar assisted heat pump dryer integrated with biomass furnace and open sun drying. The performance of these models was evaluated by comparing the coefficient of determination (R2, mean bias error (MBE, and root mean-square error (RMSE. The Page model gave the best results for representing drying kinetics of red chillies.

  13. Design and performance test of miniature capillary pumped loop for electronics cooling

    Institute of Scientific and Technical Information of China (English)

    万珍平; 皮丕辉; 付永清; 汤勇

    2008-01-01

    Considering two characteristics of compact heat dissipation room and high heat flux, a novel miniature capillary pumped loop (MCPL) for electronics cooling was proposed. MCPL consists of evaporator, condenser, vapor and liquid line dissipates heat by boiling and condensation of working fluids with no extra power consumption. Working fluid circulation is ensured by vapor pressure and capillary head. Saturated wick screens vapor and liquid, and ensures one-way flow of working fluid with no extra valve. In order to promote heat dissipation capacity of MCPL, the intensified boiling and condensation structures are embedded into evaporator and condenser respectively, which are useful to increasing boiling and condensation efficiency. Startup and run characteristics are tested by experiments in the condition of different power inputs and working fluids. MCPL is capable of dissipating 80 W of thermal energy and keeping the bottom substrate temperature of evaporator at 80 ℃.

  14. 离心泵的性能特点及应用研究%Performance characteristics and Application Research of centrifugal pump

    Institute of Scientific and Technical Information of China (English)

    徐志鹏

    2016-01-01

    In the production of petroleum and petrochemical,the application of centrifugal pump is very wide,so the application of centrifugal pump is of great significance. This paper briefly introduces the performance characteristics of centrifugal pump,centrifugal pump selection and energy saving,centrifugal pump installation,centrifugal pump and the failure of the centrifugal pump and the elimination measures are discussed and analyzed in detail.%在石油和石化生产中,离心泵的应用非常广泛,因此对离心泵的应用研究具有重要意义。文中介绍了离心泵的性能特点,从离心泵的选型、离心泵的安装、离心泵的运行以及离心泵的故障及排除措施等几个方面进行了详细的论述和分析。

  15. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  16. Performance testing of multi-metal continuous emissions monitors

    Energy Technology Data Exchange (ETDEWEB)

    Haas, W.J. [Ames Lab., IA (United States); French, N.B. [Sky+, Inc. (United States); Brown, C.H. [Oak Ridge National Lab., TN (United States); Burns, D.B. [Westinghouse Savannah River Co., Aiken, SC (United States); Lemieux, P.M.; Ryan, J.V. [National Risk Management Research Lab., Research Triangle Park, NC (United States); Priebe, S.J. [Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States); Waterland, L.R. [Acurex Environmental Corp. (United States)

    1997-11-17

    Three prototype multi-metals continuous emissions monitors (CEMs) were tested in April 1996 at the Rotary Kiln Incinerator Simulator facility at the US Environmental Protection Agency (EPA) National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The CEM instruments were: Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES); Laser Induced Breakdown Spectrometry-Atomic Emission Spectroscopy (LIBS); and Laser Spark Spectrometry, another LIBS instrument. The three CEMs were tested simultaneously during test periods in which low, medium, and high concentration levels of seven toxic metals -- antimony, arsenic, beryllium, cadmium, chromium, lead, and mercury -- were maintained under carefully controlled conditions. Two methods were used to introduce the test metals into the flue gas: (1) solution atomization, introducing metal-containing aerosol directly into the secondary combustion burner, and (2) injection of fly ash particulates. The testing addressed four measures of CEM performance: relative accuracy (RA), calibration drift, zero drift, and response time. These were accomplished by comparing the toxic metal analyte concentrations reported by the CEMs to the concentrations measured using the EPA reference method (RM) for the same analytes. Overall, the test results showed the prototype nature of the test CEMs and the clear need for further development. None of the CEMs tested consistently achieved RA values of 20% or less as required by the EPA draft performance specification. Instrument size reduction and automation will also likely need additional attention before multi-metal CEMs systems become commercially available for service as envisioned by regulators and citizens.

  17. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

    Science.gov (United States)

    Kawahito, Koji

    2013-09-01

    Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

  18. Effects of the short blade locations on the anti-cavitation performance of the splitter-bladed inducer and the pump

    Institute of Scientific and Technical Information of China (English)

    Xiaomei Guo; Zuchao Zhu; Baoling Cui; Yi Li

    2015-01-01

    In order to evaluate the effects of the short blade locations on the anti-cavitation performance of the splitter-bladed inducer and the pump, 5 inducers with different short blade locations are designed. Cavitation simulations and experimental tests of the pumps with these inducers are carried out. The algebraic slip mixture model in the CFX software is adopted for cavitation simulation. The results show that there is a vortex at the inlet of the induc-er. Asymmetric cavitation on the inducer and on the impel er is observed. The analysis shows that the short blade locations have a minor effect on the internal flow field in the inducer and on the external performance of the pump, but have a significant effect on the anti-cavitation performance. It is suggested that the inducer should be designed appropriately. The present simulations found an optimal inducer with better anti-cavitation performance.

  19. An investigation of the performance of an electronic in-line pump system for diesel engines

    Institute of Scientific and Technical Information of China (English)

    FAN Li-yun; ZHU Yuan-xian; LONG Wu-qiang; MA Xiu-zhen; XUE Ying-ying

    2008-01-01

    WIT Electronic Fuel System Co.,Ltd. has developed a new fuel injector,the Electronic In-line Pump (EIP) system,designed to meet China's diesel engine emission and fuel economy regulations. It can be used on marine diesel engines and commercial vehicle engines through different EIP systems. A numerical model of the EIP system was built in the AMESim environment for the purpose of creating a design tool for engine application and system optimization. The model was used to predict key injection characteristics under different operating conditions,such as injection pressure,injection rate,and injection duration. To validate these predictions,experimental tests were conducted under the conditions that were modeled. The results were quite encouraging and in agreement with model predictions. Additional experiments were conducted to study the injection characteristics of the EIP system. These results show that injection pressure and injection quantity are insensitive to injection timing variations,this is due to the design of the constant velocity cam profile. Finally,injection quantity and pressure vs. pulse width at different cam speeds are presented,an important injection characteristic for EIP system calibration.

  20. Distortion-Product Otoacoustic Emission Test Performance for Ototoxicity Monitoring

    Science.gov (United States)

    Reavis, Kelly M.; McMillan, Garnett; Austin, Donald; Gallun, Frederick; Fausti, Stephen A.; Gordon, Jane S.; Helt, Wendy J.; Konrad-Martin, Dawn

    2017-01-01

    Introduction A nonbehavioral method for monitoring ototoxicity in patients treated with cisplatin is needed because patients enduring chemotherapy may not be well or cooperative enough to undergo repeated hearing tests. Distortion-product otoacoustic emissions (DPOAEs) provide a nonbehavioral measure of auditory function that is sensitive to cisplatin exposure. However, interpreting DPOAE findings in the context of ototoxicity monitoring requires that their accuracy be determined in relation to a clinically accepted gold standard test. Objectives Among patients receiving cisplatin for the treatment of cancer, we sought to (1) identify the combination of DPOAE metrics and ototoxicity risk factors that best classified ears with and without ototoxic-induced hearing changes; and (2) evaluate the test performance achieved by the composite measure as well as by DPOAEs alone. Design Odds of experiencing hearing changes at a given patient visit were determined using data collected prospectively from 24 Veterans receiving cisplatin. Pure-tone thresholds were examined within an octave of each subject’s high-frequency hearing limit. DPOAE were collected as a set of four response growth (input/output) functions near the highest f2 frequency that yielded a robust response at L2 = L1 = 65 dB SPL. Logistic regression modeled the risk of hearing change using several DPOAE metrics, drug treatment factors, and other patient factors as independent variables. An optimal discriminant function was derived by reducing the model so that only statistically significant variables were included. Receiver operating characteristic curve analyses were used to evaluate test performance. Results At higher cisplatin doses, ears with better hearing at baseline were more likely to exhibit ototoxic hearing changes than those with poorer hearing. Measures of pre-exposure hearing, cumulative drug dose, and DPOAEs generated a highly accurate discriminant function with a cross-validated area under the

  1. Comparison of manual and suction pump aspiration techniques for performing bronchoalveolar lavage in 18 dogs with respiratory tract disease.

    Science.gov (United States)

    Woods, K S; Defarges, A M N; Abrams-Ogg, A C G; Viel, L; Brisson, B A; Bienzle, D

    2014-01-01

    Different aspiration techniques to retrieve bronchoalveolar lavage fluid (BALF) affect sample quality in healthy dogs. Studies evaluating these techniques in dogs with respiratory disease are lacking. To compare sample quality of BALF acquired by manual aspiration (MA) and suction pump aspiration (SPA). Eighteen client-owned dogs with respiratory disease. Randomized, blinded prospective clinical trial. Manual aspiration was performed with a 35-mL syringe attached directly to the bronchoscope biopsy channel and SPA was performed with a maximum of 50 mmHg negative pressure applied to the bronchoscope suction valve using the suction trap connection. Both aspiration techniques were performed in each dog on contralateral lung lobes, utilizing 2 mL/kg lavage volumes per site. Samples of BALF were analyzed by percentage of retrieved infusate, total nucleated cell count (TNCC), differential cell count, semiquantitative assessment of slide quality, and diagnosis score. Data were compared by paired Student's t-test, Wilcoxon signed-rank test, chi-squared test, and ANOVA. Cohen's kappa coefficient was used to assess agreement. The percentage of retrieved BALF (P = .001) was significantly higher for SPA than MA. Substantial agreement was found between cytologic classification of BALF obtained with MA and SPA (kappa = 0.615). There was no significant difference in rate of definitive diagnosis achieved with cytologic assessment between techniques (P = .78). Suction pump aspiration, compared to MA, improved BALF retrieval, but did not significantly affect the rate of diagnostic success of bronchoalveolar lavage (BAL) in dogs with pulmonary disease. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  2. Performance Monitoring Enterprise Applications with the BlackBird System

    Science.gov (United States)

    Germano, João P.; da Silva, Alberto Rodrigues; Silva, Fernando M.

    This work describes the BlackBird system, which is an analysis and monitoring service for data-intensive enterprise applications, without restrictions on the targeted architecture or employed technologies. A case study is presented for the monitoring of Billing applications from Vodafone Portugal. Monitoring systems are an essential tool for the effective management of Enterprise Applications and the attainment of the demanding service level agreements imposed to these applications. However, due to the increasing complexity and diversity of these applications, adequate monitoring systems are rarely available. The BlackBird monitoring system is able to interact with these applications through different technologies employed by the Monitored Application, and is able to produce Metrics regarding the application service level goals. The BlackBird system can be specified using a set of pre-defined Configuration Objects, allowing it to be extensible and adaptable for applications with different architectures.

  3. LK Series PLC-based Computer Monitoring System in Xintankou Pumping Station%基于LK冗余PLC的新滩口泵站计算机监控系统

    Institute of Scientific and Technical Information of China (English)

    石连东; 吴云峰; 李岚

    2011-01-01

    介绍了LK大型冗余PLC在新滩口泵站计算机监控系统的应用情况.该系统采用兄余CPU配置、冗余电源配置、冗余以太网及冗余总线配置.与上位机通过OPC的方式进行通讯,保证系统数据传输的实时性以及控制系统稳定、高效运行.%The application of LK series PLC to computer monitoring system in Xintankou Pumping Station is introduced. The system adopts redundant CPU, redundant power supply, redundant Ethernet and redundant bus-line. The communication with the upper computer is performed via OPC to ensure the real time data transmission and the stable and efficient operation of control system.

  4. Direct pumping of four levels lasing materials

    Science.gov (United States)

    Goldring, Sharone; Lavi, Raphael; Tal, Alon; Jackel, Steven M.; Lebiush, Eyal; Tzuk, Yitshak; Azoulay, Ehud

    2003-06-01

    Heat generation and laser performance were studied in Nd:YAG oscillators pumped with a Ti:Sapphire laser in two regimes: band pumping at 802nm and direct pumping at 885nm. Slope efficiencies of 52% and 57%, when pumped at 802nm and 885nm, were obtained, respectively. Heat per unit laser output was found to be 27% lower when pumped at 885nm (direct pumping regime) as compared to traditional band pumping around 808nm.

  5. Performance Evaluation of HP/ORC (Heat Pump/Organic Rankine Cycle) System with Optimal Control of Sensible Thermal Storage

    DEFF Research Database (Denmark)

    Do Carmo, Carolina Madeira Ramos; Nielsen, Mads Pagh; Elmegaard, Brian

    2016-01-01

    energy in periods of no thermal energy demand and reverses the heat pump cycle to supply electrical power. A dynamic model based on empirical data of this system is used to determine the annual performance. Furthermore, this work assesses the benefits of different control strategies that address...... of the users. Results show that real load control logic can lessen the adverse effects of cycling in the compressor of the system as well as increase the thermal demand (up to 33%) and the electrical demand (max. 8.4%) covered by renewable energy (solar). However, the extension of these improvements is highly......In energy systems with high share of renewable energy sources, like wind and solar power, it is paramount to deal with their intrinsic variability. The interaction between electric and thermal energy (heating and cooling) demands represent a potential area for balancing supply and demand that could...

  6. Genetic association studies of performance monitoring and learning from feedback: The role of dopamine and serotonin

    NARCIS (Netherlands)

    Ullsperger, M.

    2010-01-01

    Performance monitoring is essential for optimization of action outcomes. Research consistently implicates the posterior medial frontal cortex, particularly the rostral cingulate zone, in monitoring for unfavorable action outcomes, signaling the need for adjustments and learning from feedback.

  7. Experimental Adaptive Digital Performance Monitoring for Optical DP-QPSK Coherent Receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zhang, Xu; Zibar, Darko;

    2011-01-01

    We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module....

  8. Monitoring the performance of an alternative cover using caisson lysimeters

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, W.J.; Smith, G.M.; Mushovic, P.S.

    2004-02-29

    The U.S. Department of Energy (DOE) office in Grand Junction, Colorado, and the U.S. Environmental Protection Agency (EPA), Region 8, collaborated on a series of field lysimeter studies to design and monitor the performance of an alternative cover for a uranium mill tailings disposal cell at the Monticello, Utah, Superfund Site. Because groundwater recharge is naturally limited at Monticello in areas with thick loess soils, DOE and EPA chose to design a cover for Monticello using local soils and a native plant community to mimic this natural soilwater balance. Two large drainage lysimeters fabricated of corrugated steel culvert lined with high-density polyethylene were installed to evaluate the hydrological and ecological performance of an alternative cover design constructed in 2000 on the disposal cell. Unlike conventional, lowpermeability designs, this cover relies on (1) the water storage capacity of a 163-cm soil “sponge” layer overlying a sand-and-gravel capillary barrier to retain precipitation while plants are dormant and (2) native vegetation to remove precipitation during the growing season. The sponge layer consists of a clay loam subsoil compacted to 1.65 g/cm2 in one lysimeter and a loam topsoil compacted to 1.45 g/cm2 in the other lysimeter, representing the range of as-built conditions constructed in the nearby disposal cell cover. About 0.1 mm of drainage occurred in both lysimeters during an average precipitation year and before they were planted, an amount well below the EPA target of <3.0 mm/yr. However, the cover with less compacted loam topsoil sponge had a 40% greater water storage capacity than the cover with overly compacted clay loam subsoil sponge. The difference is attributable in part to higher green leaf area and water extraction by plants in the loam topsoil. The lesson learned is that seemingly subtle differences in soil types, sources, and compaction can result in salient differences in performance. Diverse, seeded communities of

  9. 自动化监测技术在大型抽水试验中的应用%Application of automatic monitoring technology to large pumping test

    Institute of Scientific and Technical Information of China (English)

    刘慧; 吴彬; 王智

    2011-01-01

    本文通过与传统监测方法比较,介绍了地下水位及流量的自动化监测技术,即利用Mini-Diver监测水位埋深并利用TC403水位流量计结合矩形堰监测流量.而且,通过对新疆温宿县台兰河地下水库大型抽水试验地下水监测的实例研究,证明该自动化监测技术的记录准确,误差小,监测数据量大,操作方便灵活,可及时掌握地下水动态变化,具有广泛的推广利用价值.%An automatic technology of monitoring on the level and flow rate of groundwater is described herein through a comparison made with the conventional monitoring methods, I. E. The buried depth of groundwater level is monitored with Mini-Diver and the flow rate is measured with TC-403 level/flow-meter combined with rectangular weir. Furthermore, based on the case study made on the groundwater monitoring for the large pumping test of the groundwater reservoir in Tailanhe River Basin within Wensu County of Xinjiang, the technology is demonstrated to have the merits such as accurate recording, small error, large amount of monitoring data, convenient and flexible to be operated, etc. , and can monitor the dynamic variation of ground water in time, and then it has a usable value to be widely popularized as well.

  10. Servo Controlled Variable Pressure Modification to Space Shuttle Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.

    1983-01-01

    Engineering drawings show modifications made to the constant pressure control of the model AP27V-7 hydraulic pump to an electrically controlled variable pressure setting compensator. A hanger position indicator was included for continuously monitoring hanger angle. A simplex servo driver was furnished for controlling the pressure setting servovalve. Calibration of the rotary variable displacement transducer is described as well as pump performance and response characteristics.

  11. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  12. Effect of heating system using a geothermal heat pump on the production performance and housing environment of broiler chickens.

    Science.gov (United States)

    Choi, H C; Salim, H M; Akter, N; Na, J C; Kang, H K; Kim, M J; Kim, D W; Bang, H T; Chae, H S; Suh, O S

    2012-02-01

    A geothermal heat pump (GHP) is a potential heat source for the economic heating of broiler houses with optimum production performance. An investigation was conducted to evaluate the effect of a heating system using a GHP on production performance and housing environment of broiler chickens. A comparative analysis was also performed between the GHP system and a conventional heating system that used diesel for fuel. In total, 34,000 one-day-old straight run broiler chicks were assigned to 2 broiler houses with 5 replicates in each (3,400 birds/replicate pen) for 35 d. Oxygen(,) CO(2), and NH(3) concentrations in the broiler house, energy consumption and cost of heating, and production performance of broilers were evaluated. Results showed that the final BW gain significantly (P heating system did not affect the mortality of chicks during the first 4 wk of the experimental period, but the mortality markedly increased in the conventional broiler house during the last wk of the experiment. Oxygen content in the broiler house during the experimental period was not affected by the heating system, but the CO(2) and NH(3) contents significantly increased (P heating the GHP house was significantly lower (P heating system for broiler chickens.

  13. Numerical simulation of pumping performance of diode side pumped thin disk laser%二极管侧面泵浦薄片激光器泵浦性能数值仿真

    Institute of Scientific and Technical Information of China (English)

    郭渭荣; 李强; 冯驰; 晏乐伦; 王金国

    2012-01-01

    Taking advantage of the symmetry in the distribution of the absorbed pump power density of a diode side pumped thin disk laser, the pump uniformity could be described quantitively with a novel method that took values on key points of absorbed pump power density distribution into consideration. A pump performance index that considered both pump uniformity and absorption efficiency was introduced. Pump performance index within certain ranges of diode array distance, round thin disk radius and absorption coefficient were compared. Results of calculation show that the performance index reaches an optimized minimum of 0.1110 with the round thin disk radius of 13 mm, the diode array distance of 37 mm, and the absorption coefficient of 0.10 mm-1. A performance index near to the optimized value could be obtained with the parameters experimentally used. Tentative experiment measured the phase distortion on the thin disk caused by thermal effects. The computed phase distortion matches with experimentally measured phase distortion. Pump performance index and related calculation results presented in this paper presents a useful theoretical reference for research of diode side pumped composite thin disk lasers.%利用二极管侧面泵浦薄片激光器泵浦分布的对称性,通过泵浦分布中的特殊点对泵浦均匀性进行定量描述的方法,提出了由泵浦均匀性和吸收效率共同表征的泵浦性能指标,并使用该指标对一定范围内的阵列距离、圆薄片晶体尺寸和吸收系数的泵浦性能进行了对比.在一定取值范围内,当圆薄片晶体半径为13mm、阵列与晶体中心间距为37 mm、吸收系数为0.10 mm-1时,泵浦性能指标达到最小值0.1110.采用接近最优泵浦性能指标值的泵浦参数进行实验,初步测量了热效应造成的薄片相位畸变,根据泵浦分布计算出的相位畸变分布与实验结果基本相符.文中提出的泵浦性能指标和相应计算结果为薄片激光器的

  14. 声发射技术在抽杆疲劳实验中的应用%Application of acoustic emission (AE) technique in crack monitor during fatigue test of pump rods

    Institute of Scientific and Technical Information of China (English)

    夏永发; 李海玲

    2007-01-01

    The acoustic emission(AE)real time monitoring of fatigue damage of pump rods samples during fatigue test was introduced.Under severe environmental noise caused by vibration,the real time monitoring of the fatigue crack initiation and expansion was realized successfully by using the parameters analysis method combined by AE Hits and Amplitude.The characters of the methods are simple and real time,which can provide a more accurate and impersonal basis for judging whether the fatigue test piece has been destroyed,thus can provide a scientific assistant method for accurately determining the life of pump rod.

  15. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  16. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  17. Heat pumps in industry. Pt. 2: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Padova Univ., Vicenza (Italy). Ist. di Ingegneria Gestionale

    1995-04-01

    A selection of applications of heat pumps in industry is described, reporting plant lay-outs and performances. The selection includes compression heat pumps at different temperatures, vapour recompression systems, absorption heat pumps and heat transformers. (author)

  18. A high performance, electric pump-fed LOX / RP propulsion system Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To-date, the realization of small-scale, high-performance liquid bipropellant rocket engines has largely been limited by the inability to operate at high chamber...

  19. High Performance Fiber-Optic Sensor for Environmental Monitoring Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Los Gatos Research (LGR) proposes to develop a low-cost, compact, lightweight, rugged and easy-to-use environmental monitoring optical fiber sensor device based on...

  20. High-Performance Contaminant Monitor for Spacecraft Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Vision for Space Exploration demands increasing reliance on real-time trace gas monitors onboard spacecraft. Present grab samples and badges will be inadequate...

  1. Comparison of Pumped and Diffusion Sampling Methods to Monitor Concentrations of Perchlorate and Explosive Compounds in Ground Water, Camp Edwards, Cape Cod, Massachusetts, 2004-05

    Science.gov (United States)

    LeBlanc, Denis R.; Vroblesky, Don A.

    2008-01-01

    Laboratory and field tests were conducted at Camp Edwards on the Massachusetts Military Reservation on Cape Cod to examine the utility of passive diffusion sampling for long-term monitoring of concentrations of perchlorate and explosive compounds in ground water. The diffusion samplers were constructed of 1-inch-diameter rigid, porous polyethylene tubing. The results of laboratory tests in which diffusion samplers were submerged in containers filled with ground water containing perchlorate, RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) indicate that concentrations inside the diffusion samplers equilibrated with concentrations in the containers within the 19-day-long test period. Field tests of the diffusion samplers were conducted in 15 wells constructed of 2- or 2.5-inch-diameter polyvinyl chloride pipe with 10-foot-long slotted screens. Concentrations of perchlorate, RDX, and HMX in the diffusion samplers placed in the wells for 42 to 52 days were compared to concentrations in samples collected by low-flow pumped sampling from 53 days before to 109 days after retrieval of the diffusion samples. The results of the field tests indicate generally good agreement between the pumped and diffusion samples for concentrations of perchlorate, RDX, and HMX. The concentration differences indicate no systematic bias related to contaminant type or concentration levels.

  2. Performance testing of an air/water heat pump using CO{sub 2} (R744) as refrigerant for the preparation of sanitary hot water in a hospital; Mesures des donnees energetiques d'une pompe a chaleur air/eau au CO{sub 2} (R744) pour preparation d'eau chaude sanitaire dans un hopital

    Energy Technology Data Exchange (ETDEWEB)

    Anstett, P.

    2006-07-01

    This final report prepared for the Swiss Federal Office of Energy (SFOE) describes the monitoring equipment and the results of performance tests made on a prototype heat pump of 60 kW power output used for hot water production at the hospital of Le Locle, Switzerland. The heat pump uses carbon dioxide (R744) as the working fluid and ambient air as the heat source. The heat output and the coefficient of performance for various values of cold water temperature and air temperature have been measured. The practically measured values of heat output and COP showed a low reproducibility and remained far behind the theoretical values given by the manufacturer. Instead of producing hot water at 80 {sup o}C as intended originally the authors recommend to use the heat pump only for preheating the water to 60 {sup o}C.

  3. Absorber and gain chip optimization to improve performance from a passively modelocked electrically pumped vertical external cavity surface emitting laser

    Energy Technology Data Exchange (ETDEWEB)

    Zaugg, C. A., E-mail: zauggc@phys.ethz.ch; Mangold, M.; Pallmann, W. P.; Golling, M.; Tilma, B. W.; Keller, U. [Department of Physics, Institute for Quantum Electronics, ETH Zürich, 8093 Zürich (Switzerland); Gronenborn, S.; Moench, H.; Weichmann, U. [Philips Technologie GmbH Photonics Aachen, Steinbachstrasse 15, 52074 Aachen (Germany); Miller, M. [Philips Technologie GmbH U-L-M Photonics, Lise-Meitner-Strasse 13, 89081 Ulm (Germany)

    2014-03-24

    We present an electrically pumped vertical-external-cavity surface-emitting laser (EP-VECSEL) modelocked with a semiconductor saturable absorber mirror (SESAM) with significantly improved performance. In different cavity configurations, we present the shortest pulses (2.5 ps), highest average output power (53.2 mW), highest repetition rate (18.2 GHz), and highest peak power (4.7 W) to date. The simple and low-cost concept of EP-VECSELs is very attractive for mass-market applications such as optical communication and clocking. The improvements result from an optimized gain chip from Philips Technologie GmbH and a SESAM, specifically designed for EP-VECSELs. For the gain chip, we found a better trade-off between electrical and optical losses with an optimized doping scheme in the substrate to increase the average output power. Furthermore, the device's bottom contact diameter (60 μm) is smaller than the oxide aperture diameter (100 μm), which favors electro-optical conversion into a TEM{sub 00} mode. Compared to optically pumped VECSELs we have to increase the field enhancement in the active region of an EP-VECSEL which requires a SESAM with lower saturation fluence and higher modulation depth for modelocking. We therefore used a resonant quantum well SESAM with a 3.5-pair dielectric top-coating (SiN{sub x} and SiO{sub 2}) to enhance the field in the absorber at the lasing wavelength of 980 nm. The absorption bandedge at room temperature is detuned (965 nm) compared to the resonance (980 nm), which enables temperature-tuning of the modulation depth and saturation fluence from approximately 2.5% up to 15% and from 20 μJ/cm{sup 2} to 1.1 μJ/cm{sup 2}, respectively.

  4. Absorber and gain chip optimization to improve performance from a passively modelocked electrically pumped vertical external cavity surface emitting laser

    Science.gov (United States)

    Zaugg, C. A.; Gronenborn, S.; Moench, H.; Mangold, M.; Miller, M.; Weichmann, U.; Pallmann, W. P.; Golling, M.; Tilma, B. W.; Keller, U.

    2014-03-01

    We present an electrically pumped vertical-external-cavity surface-emitting laser (EP-VECSEL) modelocked with a semiconductor saturable absorber mirror (SESAM) with significantly improved performance. In different cavity configurations, we present the shortest pulses (2.5 ps), highest average output power (53.2 mW), highest repetition rate (18.2 GHz), and highest peak power (4.7 W) to date. The simple and low-cost concept of EP-VECSELs is very attractive for mass-market applications such as optical communication and clocking. The improvements result from an optimized gain chip from Philips Technologie GmbH and a SESAM, specifically designed for EP-VECSELs. For the gain chip, we found a better trade-off between electrical and optical losses with an optimized doping scheme in the substrate to increase the average output power. Furthermore, the device's bottom contact diameter (60 μm) is smaller than the oxide aperture diameter (100 μm), which favors electro-optical conversion into a TEM00 mode. Compared to optically pumped VECSELs we have to increase the field enhancement in the active region of an EP-VECSEL which requires a SESAM with lower saturation fluence and higher modulation depth for modelocking. We therefore used a resonant quantum well SESAM with a 3.5-pair dielectric top-coating (SiNx and SiO2) to enhance the field in the absorber at the lasing wavelength of 980 nm. The absorption bandedge at room temperature is detuned (965 nm) compared to the resonance (980 nm), which enables temperature-tuning of the modulation depth and saturation fluence from approximately 2.5% up to 15% and from 20 μJ/cm2 to 1.1 μJ/cm2, respectively.

  5. Optimization of compound gear pump

    Institute of Scientific and Technical Information of China (English)

    栾振辉

    2002-01-01

    This paper introduces the performances of compound gear pump. Based on the target of having the smallest mass per unit volume, the paper established a mathematical model of optimization, and obtained the results of optimization of the pump.

  6. Numerical Investigation on the Influence of Nozzle Lip Thickness on the Flow Field and Performance of an Annular Jet Pump

    Institute of Scientific and Technical Information of China (English)

    LongZhou Xiao; XinPing Long; XueLong Yang

    2014-01-01

    The performance of an annular jet pump ( AJP ) is determined by its area ratio A ( ratio of cross sectional area of throat and annular nozzle) and flow rate ratio q ( ratio of primary and secondary flow rate, Qs/Qj ) , while the nozzle lip thickness is neglected in the present studies. This paper presents a study on the effect of the thickness on the flow field and performance of an AJP with A = 1�75. With the increasing flow rate ratio and nozzle lip thickness, a small vortex forms at the nozzle lip and keeps on growing. However, as the flow rate ratio or nozzle lip thickness is extremely low, the vortex at the lip vanishes thoroughly. Moreover, the recirculation width varies conversely with the nozzle lip thickness when the flow rate ratio q≤0�13. While the deviation of the recirculation width with different nozzle lip thickness is negligible with q≥0�13. Additionally the existence of nozzle lip hinders the momentum exchange between the primary and secondary flow and leads to a mutation of velocity gradient near the nozzle exit, which shift the recirculation downstream. Finally, based on the numerical results of the streamwise and spanwise vortex distributions in the suction chamber, the characteristics of the mixing process and the main factors accounting for the AJP performance are clarified.

  7. 液压泵性能测试实验台设计%Design of Performance Test Bench for Hydraulic Pump

    Institute of Scientific and Technical Information of China (English)

    郑明辉; 江吉彬; 郭熛

    2011-01-01

    Hydraulic pump as hydraulic system's power part, is one of important parts of engineering machinery product. The hydraulic pump performance test bench is the necessary device for hydraulic pump product quality examination which is the main safe guard of pump product quality. A hydraulic pump performance test bench was designed. The composition, working principle and char acteristics of the hydraulic system were introduced. Data test and analysis were carried on.%液压泵作为液压系统的动力元件,是工程机械产品的重要部件之一.液压泵性能测试实验台是进行液压泵产品质量检测的必要设备,是泵产品质量监控的主要保障.设计了液压泵性能测试实验台,介绍液压系统组成、工作原理和特点,并进行了数据测试及分析.

  8. Performance Analysis of Stirling Engine-Driven Vapor Compression Heat Pump System

    Science.gov (United States)

    Kagawa, Noboru

    Stirling engine-driven vapor compression systems have many unique advantages including higher thermal efficiencies, preferable exhaust gas characteristics, multi-fuel usage, and low noise and vibration which can play an important role in alleviating environmental and energy problems. This paper introduces a design method for the systems based on reliable mathematical methods for Stirling and Rankin cycles using reliable thermophysical information for refrigerants. The model deals with a combination of a kinematic Stirling engine and a scroll compressor. Some experimental coefficients are used to formulate the model. The obtained results show the performance behavior in detail. The measured performance of the actual system coincides with the calculated results. Furthermore, the calculated results clarify the performance using alternative refrigerants for R-22.

  9. THE FEATURES OF AIRCRAFT FUNCTIONAL SYSTEMS PERFORMANCE MONITORING

    Directory of Open Access Journals (Sweden)

    Stanislav Alexandrovich Krotov

    2017-01-01

    Full Text Available The key steps of aircraft essential parameters and events monitoring during its operation are considered in the arti- cle. Conditions for specific risk monitoring are also presented.The notion of fail-safe feature of aircraft functional systems is analysed, and the necessity of continuous process of safety flight level estimate is shown. The method of quantitative assessment of key events and risks probabilities with the use of modern software is proposed. This method contains 5 basic stages: The monitoring parameters setting - this stage is initial and begins with the consideration of organization safety cul- ture, the main purposes and problems determination, the basic parameters and characteristics forming which are to be monitored. The event monitoring in operation - on this stage continuous process of key events searching and monitoring which are a thing of importance within the framework of the established problems takes place. This process is closely relat- ed to parameters monitoring set on the first stage. The event and risk estimate - this stage begins directly after the event has been discovered. The estimate pro- cess is as long as it is required to identify the event gravity. It also contains the preliminary risk estimate for using in priori- tization of initial expanded estimate and in the working out of plan for activities realization. The working out of plan for activities - on this stage correction data is determined that will make changes to aero- technics working out, operation, maintenance and to staff training directly in linkage to the problem event identified earlier. The activity carrying-out - the realization of actions according to the activity plan. This stage concludes priori- tization, planning and problem carrying-out. The dependence set between the probability of failure situations and the degree of their danger is shown. The key factors which are subject to be estimated while aircraft operating and which aim with

  10. Performance evaluation of pumping systems used in commercial-scale, split-pond aquaculture

    Science.gov (United States)

    Split-pond aquaculture systems have been adopted widely by United States catfish farmers as a way to improve production performance. The split-pond consists of a fish-culture basin that is connected to a waste-treatment lagoon by two water conveyance structures. Water is circulated between the two b...

  11. A dynamic performance simulation model of flat-plate solar collectors for a heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Arinze, E.A.; Schoenau, G.J.; Sokhansanj, S. (Saskatchewan Univ., Saskatoon, SK (Canada). College of Engineering); Adefila, S.S.; Mumah, S.M. (Ahmadu Bello Univ., Zaria (Nigeria). Dept. of Chemical Engineering)

    1993-01-01

    Flat-plate collectors are inherently exposed to time-varying meteorological and system parameters. Thus, dynamic modeling, rather than the commonly used steady-state models, is a more accurate approach for the design and performance evaluation of flat-plate solar collectors. The dynamic model presented in this study describes the fluid, plate and cover temperatures of the collector by three different differential equations. Taylor series expansion and the Runge-Kutta method are used in the solution of the differential equations. The accuracy of the dynamic model was tested by comparing the results predicted by the model with experimental performance data obtained for a liquid-cooled flat-plate solar collector with a corrugated transparent fiberglass cover. The predicted results by the dynamic model agreed favorably with the measured experimental data for the flat-plate solar collector. Experimentally determined collector temperatures varied by a maximum of [+-]3[sup o]C from values predicted by the model. (Author)

  12. Energy Performance and Economic Evaluations of the Geothermal Heat Pump System used in the KnowledgeWorks I and II Buildings, Blacksburg, Virginia

    OpenAIRE

    Charoenvisal, Kongkun

    2008-01-01

    Heating, Ventilating and Air Conditioning Systems (HVAC) are not only one of the most energy consuming components in buildings but also contribute to green house gas emissions. As a result often environmental design strategies are focused on the performance of these systems. New HVAC technologies such as Geothermal Heat Pump systems have relatively high performance efficiencies when compared to typical systems and therefore could be part of whole-building performance design strategies.In coll...

  13. A Numerical Study on the Improvement of Suction Performance and Hydraulic Efficiency for a Mixed-Flow Pump Impeller

    Directory of Open Access Journals (Sweden)

    Sung Kim

    2014-01-01

    Full Text Available This paper describes a numerical study on the improvement of suction performance and hydraulic efficiency of a mixed-flow pump by impellers. The design of these impellers was optimized using a commercial CFD (computational fluid dynamics code and DOE (design of experiments. The design variables of meridional plane and vane plane development were defined for impeller design. In DOE, variables of inlet part were selected as main design variables in meridional plane, and incidence angle was selected in vane plane development. The verification of the experiment sets that were generated by 2k factorial was done by numerical analysis. The objective functions were defined as the NPSHre (net positive suction head required, total efficiency, and total head of the impellers. The importance of the geometric design variables was analyzed using 2k factorial designs. The interaction between the NPSHre and total efficiency, according to the meridional plane and incidence angle, was discussed by analyzing the 2k factorial design results. The performance of optimally designed model was verified by experiments and numerical analysis and the reliability of the model was retained by comparison of numerical analysis and comparative analysis with the reference model.

  14. Performance monitoring in autism spectrum disorders: A systematic literature review of event-related potential studies.

    Science.gov (United States)

    Hüpen, Philippa; Groen, Yvonne; Gaastra, Geraldina F; Tucha, Lara; Tucha, Oliver

    2016-04-01

    Autism spectrum disorder (ASD) is marked by impairments in social-emotional situations, executive functioning, and behavioral regulation. These symptoms may be related to deficits in performance monitoring, i.e., the ability to observe and evaluate one's own behavior and performance which is necessary for the regulation of future behavior. The present literature review investigated electroencephalic correlates of performance monitoring in ASD. Event-related potentials (ERPs) considered in this review included internal performance monitoring components (error-related negativity, error positivity), external performance monitoring components (feedback-related negativity, feedback-P3), and observational performance monitoring components (observer error-related negativity, observer feedback-related negativity). The majority of studies point to reduced internal performance monitoring in ASD. External performance monitoring in reward-processing paradigms, where rewards are independent of performance, seems to be intact in ASD. So far, no studies have investigated the observer error-related negativity in ASD. Available data on the observer feedback-related negativity are inconclusive, since only two studies with differential study results investigated this construct in ASD. In general, results suggest that individuals with ASD have problems with internal performance monitoring and with learning from external, abstract feedback. In contrast, the processing of external, concrete feedback seems to be largely intact in ASD.

  15. Biomedical performance monitoring and assessment of astronauts by means of an ocular vestibular monitoring system

    Science.gov (United States)

    Souvestre, Philippe A.; Landrock, Clinton

    2007-02-01

    The paper focuses on the strong correlation between unmitigated symptoms exhibited by post Space flight astronauts, and symptoms associated with postural deficiency syndrome (PDS) that can be correctly assessed, identified, and monitored via a neurophysiological ocular-vestibular monitoring system (OVMS). From examining clinical data taken over a 10-year period from patients experiencing PDS related acute and chronic post-traumatic medical conditions, the authors show the potential for current assessment and monitoring techniques to examine better the impacts on astronaut neurophysiology. The data presented provide strong evidence that this biomedical monitoring and assessment methodology along with appropriate technology can lead to a better understanding of astronaut post-flight neurophysiology, which is necessary if human exploration in Space is to continue on a successful path.

  16. Performance assessment of a new laser system for efficient spin exchange optical pumping in a spin maser measurement of {sup 129}Xe EDM

    Energy Technology Data Exchange (ETDEWEB)

    Funayama, C., E-mail: funayama@yap.nucl.ap.titech.ac.jp [Tokyo Institute of Technology, Department of Physics (Japan); Furukawa, T. [Tokyo Metropolitan University, Department of Physics (Japan); Sato, T.; Ichikawa, Y.; Ohtomo, Y.; Sakamoto, Y.; Kojima, S.; Suzuki, T.; Hirao, C.; Chikamori, M.; Hikota, E.; Tsuchiya, M. [Tokyo Institute of Technology, Department of Physics (Japan); Yoshimi, A. [Okayama University, Research Core for Extreme Quantum World (Japan); Bidinosti, C. P. [University of Winnipeg, Department of Physics (Canada); Ino, T. [Institute of Material Structure Science, High Energy Accelerator Research Organization (KEK) (Japan); Ueno, H. [RIKEN Nishina Center, RIKEN (Japan); Matsuo, Y. [Hosei University, Department of Advanced Sciences (Japan); Fukuyama, T. [Osaka University, Research Center for Nuclear Physics (RCNP) (Japan); Asahi, K. [Tokyo Institute of Technology, Department of Physics (Japan)

    2015-11-15

    We demonstrate spin-exchange optical pumping of {sup 129}Xe atoms with our newly made laser system. The new laser system was prepared to provide higher laser power required for the stable operation of spin maser oscillations in the {sup 129}Xe EDM experiment. We studied the optimum cell temperature and pumping laser power to improve the degree of {sup 129}Xe spin polarization. The best performance was achieved at the cell temperature of 100 {sup ∘}C with the presently available laser power of 1 W. The results show that a more intense laser is required for further improvement of the spin polarization at higher cell temperatures in our experiment.

  17. Magnetocaloric pump

    Science.gov (United States)

    Brown, G. V.

    1973-01-01

    Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

  18. Enhanced Component Performance Study: Motor-Driven Pumps 1998–2012

    Energy Technology Data Exchange (ETDEWEB)

    T. E. Wierman

    2013-10-01

    This report presents an enhanced performance evaluation of motor-driven valves (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). The MDP failure modes considered for standby systems are failure to start, failure to run less than or equal to 1 hour, and failure to run more than 1 hour; for normally running systems, the failure modes considered are failure to start and failure to run. An 8 hr unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant increasing trend was identified in the MDP results for standby MDP run hours per reactor critical year. Statistically significant decreasing trends were identified for unreliability (for standby and normally running systems) frequency of failure-to-start events for standby systems and failure probability for standby systems.

  19. Technology Solutions Case Study: Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Transformations, Inc., has extensive experience building high-performance homes - production and custom - in a variety of Massachusetts locations and uses mini-split heat pumps (MSHPs) for space conditioning in most of its homes. The use of MSHPs for simplified space-conditioning distribution provides significant first-cost savings, which offsets the increased investment in the building enclosure. In this project, the U.S. Department of Energy Building America team Building Science Corporation evaluated the long-term performance of MSHPs in 8 homes during a period of 3 years. The work examined electrical use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions.

  20. Biomass performance : monitoring and control in bio-pharmaceutical production

    NARCIS (Netherlands)

    Neeleman, R.

    2002-01-01

    The primary concern in the pharmaceutical industry is not the optimisation of product yield or the reduction of manufacturing cost, but the production of a product of consistently high quality. This has resulted in 'process monitoring' becoming an integral part of process operation. In this