WorldWideScience

Sample records for monitor partial pressure

  1. Intracranial pressure monitoring

    Science.gov (United States)

    ICP monitoring; CSF pressure monitoring ... There are 3 ways to monitor pressure in the skull (intracranial pressure). INTRAVENTRICULAR CATHETER The intraventricular catheter is the most accurate monitoring method. To insert an intraventricular catheter, a ...

  2. Home monitoring of blood pressure

    OpenAIRE

    McGrath, Barry P.

    2015-01-01

    Home blood pressure monitoring is the self-measurement of blood pressure by patients. In the diagnosis and management of high blood pressure it is complementary to 24-hour ambulatory blood pressure monitoring and clinic blood pressure measurements. Home monitoring can also help to identify white-coat and masked hypertension.

  3. DIGITAL BLOOD PRESSURE MONITOR

    Directory of Open Access Journals (Sweden)

    R. Fuentes

    2004-12-01

    Full Text Available In this work we present a blood pressure monitor which measures both the high blood pressure (systolic pressure,and the low blood pressure (diastolic pressure. It is a semiautomatic meter because the inflation of the occlusivecuff is carried out in a manual way. The transducer used is a piezoresistive silicon pressure sensor integrated onchip which provides a proportional voltage to the input pressure, with a measurement range from 0 to 50 kPa (0–7.3 PSI. The oscillometric method is employed, which consists on detecting the oscillometric signal on brachialartery, being processed at each pressure step, when the cuff is gradually deflated. Signal sampling is carried out ata rate determined by the heart rate.In order to program the digital electronics of the circuit we used Altera tools, with the compiler MAX-PLUS II, andthe device selected to implement the design was an EPM7128SLC84-15 CPLD (Complex Programmable LogicDevice

  4. 经皮氧分压监测在骨科手术中的应用%Application of transcutaneous partial pressure of oxygen monitoring in orthopedics surgery

    Institute of Scientific and Technical Information of China (English)

    公茂伟; 米卫东; 傅强; 刘靖; 张宏

    2011-01-01

    目的 评价经皮氧分压(TcPO2)监测在临床麻醉中的应用价值.方法 对28例在全麻下实施骨科手术的患者进行持续TcPO2监测,分别在吸入氧浓度(FiO2)为21%、40%、70%与100%时进行动脉血气分析测定,并与动脉血氧分压(Pa02)进行对比,比较4组不同FiO2的经皮氧分压指数(TcPO2/PaO2).结果 在不同吸入氧浓度的条件下,TcPO2与PaO2之间均呈显著正相关,FiO2为21%时TcPO2与PaO2相关系数r=0.599(P<0.01),FiO2为40%时r=0.715(P<0.01),FiO2为70%时r=0.718(P<0.01),FiO2为100%时r=0.708(P<0.01).4组TePO2/PaO2/无显著性差异(P=0.063).结论 TcPO2/能够较准确地反映PaO2/的变化趋势,并且TcPO2/PaO2可有效地反映组织灌注,经皮氧分压监测技术在临床麻醉中应用具有可行性.%Objective To evaluate the application value of transcutaneous partial pressure of oxygen (TcPO2) monitoring in clinical anesthesia. Methods Twenty-eight patients who underwent general anesthesia and orthopedics surgery were studied. The inhaled oxygen concentrations (FiO2) were 21%, 40%, 70% and 100%, and the TcPO2 were measured with TC devices and arterial blood gas analysis were tested simultaneously. Measurements of TcPO2 were compared with arterial blood oxygen pressure(PaO2) in different inhaled oxygen concentrations respectively, and four groups of transcutaneous oxygen indexes (TcPO2/PaO2) were compared. Results Although inhaled oxygen concentrations were different, TcPO2 correlated positively with PaO2. When FiO2 was 21%, the correlation coefficients ( r )for TcPO2 and PaO2 was 0.599 (P< 0.01); while when FiO2 was 40%, 70% and 100%, the rwas 0.715 (P< 0.01), 0.718 (P< 0.01), and 0.708 respectively(P < 0.01). There was no significant difference in four groups in TcPO2/PaO2 (P = 0.063). Conclusions TcPO2 reflects the trend of PaO2 change more accurately and TcPO2/PaO2 can effectively reflect tissue perfusion. Transcutaneous partial pressure of oxygen monitoring in

  5. INTRACRANIAL PRESSURE MONITORING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Ida Bagus Adi Kayana

    2013-03-01

    Full Text Available Head injury is the most significant cause of increased morbidity and mortality. An estimated 1.4 million head injuries occur each year, with and more than 1.1 million come to the Emergency Unit. On each patient head injury, an increase in intracranial pressure (ICP related to poor outcomes and aggressive therapy to increased ICP can improve the outcomes. ICP monitoring is the most widely used because of the prevention and control of ICP as well as maintain the pressure increase perfusion of cerebral (Cerebral Perfusion Pressure/CPP is the basic purpose of handling head injury. There are two methods of monitoring ICP that is an invasive methods (directly and non-invasive techniques (indirectly. The method commonly used, namely intraventricular and intraparenkimal (microtransducer sensor because it is more accurate but keep attention to the existence of the risk of bleeding and infection resulting from installation. Monitoring of ICT can determine the actions that avoid further brain injury, which can be lethal and irreversibel.

  6. INTRACRANIAL PRESSURE MONITORING

    Directory of Open Access Journals (Sweden)

    Retno Widiyanthi

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Intracranial pressure is total of pressure that is produced by brain, blood, and cerebrospinal fluid/CSF in the tight cranial space. As a respon to intracranial pressure increasing, compensation begin by movement of CSF from ventricle to cerebral subarachnoidal space, and increase the absorption of CSF. Increasing of ICP usually caused by increasing of brain volume (cerebral oedem, blood (intracranial bleeding, space occupying lesion, or CSF (hidrocephalus. Indication in ICP monitoring can be seen from : neurological criteria, abnormal CT-scan result when admission, normal CT-scan result, but had more two risk factors. According to the procedure that must be done, there are two methods in ICP monitoring: invasive ICP monitoring methodes and non-invasive measuring method. Increasing of ICP will decrease the compliance of brain, pulsation of artery more clearly, and the component of vein is lost. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  7. Intracranial Pressure Monitoring

    DEFF Research Database (Denmark)

    Raboel, P H; Bartek, J; Andresen, M;

    2012-01-01

    Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as ......-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP....... as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold...

  8. Oxygen partial pressure control for microgravity experiments

    OpenAIRE

    Schulz, Michael; Brillo, Jürgen; Stenzel, Christian; Fritze, Holger

    2012-01-01

    A system consisting of a high-temperature yttrium-stabilized zirconia (YSZ) based oxygen ion pump and potentiometric sensor enables precise measurement and control of oxygen partial pressure, pO2, at elevated temperatures within 0.2 to 10^-20 bar.

  9. Blood pressure monitors for home

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... ask you to keep track of your blood pressure at home. To do this, you will need ...

  10. Computing the partial volume of pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wiencke, Bent [Nestle USA, Corporate Engineering, 800 N. Brand Blvd, Glendale, CA 91203 (United States)

    2010-06-15

    The computation of the partial and total volume of pressure vessels with various type of head profiles requires detailed knowledge of the head profile geometry. Depending on the type of head profile the derivation of the equations can become very complex and the calculation process cumbersome. Certain head profiles require numerical methods to obtain the partial volume, which for most application is beyond the scope of practicability. This paper suggests a unique method that simplifies the calculation procedure for the various types of head profiles by using one common set of equations without the need for numerical or complex computation methods. For ease of use, all equations presented in this paper are summarized in a single table format for horizontal and vertical vessels. (author)

  11. Arterial Pressure Monitoring in Mice

    Science.gov (United States)

    Zhao, Xin; Ho, David; Gao, Shumin; Hong, Chull; Vatner, Dorothy E.; Vatner, Stephen F.

    2011-01-01

    The use of mice for the evaluation and study of cardiovascular pathophysiology is growing rapidly, primarily due to the relative ease for developing genetically engineered mouse models. Arterial pressure monitoring is central to the evaluation of the phenotypic changes associated with cardiovascular pathology and interventions in these transgenic and knockout models. There are four major techniques for measuring arterial pressure in the mouse: tail cuff system, implanted fluid filled catheters, Millar catheters and implanted telemetry systems. Here we provide protocols for their use and discuss the advantages and limitations for each of these techniques . PMID:21686061

  12. Estimation of vapour pressure and partial pressure of subliming compounds by low-pressure thermogravimetry

    Indian Academy of Sciences (India)

    G V Kunte; Ujwala Ail; P K Ajikumar; A K Tyagi; S A Shivashankar; A M Umarji

    2011-12-01

    A method for the estimation of vapour pressure and partial pressure of subliming compounds under reduced pressure, using rising temperature thermogravimetry, is described in this paper. The method is based on our recently developed procedure to estimate the vapour pressure from ambient pressure thermogravimetric data using Langmuir equation. Using benzoic acid as the calibration standard, vapour pressure–temperature curves are calculated at 80, 160 and 1000 mbar for salicylic acid and vanadyl bis-2,4-pentanedionate, a precursor used for chemical vapour deposition of vanadium oxides. Using a modification of the Langmuir equation, the partial pressure of these materials at different total pressures is also determined as a function of temperature. Such data can be useful for the deposition of multi-metal oxide thin films or doped thin films by chemical vapour deposition (CVD).

  13. A system for incubations at high gas partial pressure

    DEFF Research Database (Denmark)

    Sauer, Patrick; Glombitza, Clemens; Kallmeyer, Jens

    2012-01-01

    High-pressure is a key feature of deep subsurface environments. High partial pressure of dissolved gasses plays an important role in microbial metabolism, because thermodynamic feasibility of many reactions depends on the concentration of reactants. For gases, this is controlled by their partial...... pressure, which can exceed 1 MPa at in situ conditions. Therefore, high hydrostatic pressure alone is not sufficient to recreate true deep subsurface in situ conditions, but the partial pressure of dissolved gasses has to be controlled as well. We developed an incubation system that allows for incubations...... and inert PVDF (polyvinylidene fluoride) incubator sleeve, which is almost impermeable for gases, holds the sample and separates it from the pressure fluid. The flexibility of the incubator sleeve allows for sub-sampling of the medium without loss of pressure. Experiments can be run in both static and flow...

  14. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  15. Report on ISS Oxygen Production, Resupply, and Partial Pressure Management

    Science.gov (United States)

    Schaezler, Ryan; Ghariani, Ahmed; Leonard, Daniel; Lehman, Daniel

    2011-01-01

    The majority of oxygen used on International Space Station (ISS) is for metabolic support and denitrogenation procedures prior to Extra-Vehicular Activities. Oxygen is supplied by various visiting vehicles such as the Progress and Shuttle in addition to oxygen production capability on both the United States On-Orbit Segment (USOS) and Russian Segment (RS). To maintain a habitable atmosphere the oxygen partial pressure is controlled between upper and lower bounds. The full range of the allowable oxygen partial pressure along with the increased ISS cabin volume is utilized as a buffer allowing days to pass between oxygen production or direct addition of oxygen to the atmosphere from reserves. This paper summarizes amount of oxygen supplied and produced from all of the sources and describes past experience of managing oxygen partial pressure along with the range of management options available to the ISS.

  16. Ashcroft Pressure Switch Monitor for Low SCHe Purge Pressure

    Energy Technology Data Exchange (ETDEWEB)

    VAN KATWIJK, C.

    2000-06-21

    These 0-15 psig pressure switches are located in the SCHe helium purge lines after PCV-5*23 and before PCV-5*27. The pressure switches monitor the pressure being maintained between the two PCVs and actuate on low pressure of 15 psig. This design is used for each of the SCHe supply lines (4). Electronic output signal is NON-SAFETY (GS).

  17. A system for incubations at high gas partial pressure.

    Science.gov (United States)

    Sauer, Patrick; Glombitza, Clemens; Kallmeyer, Jens

    2012-01-01

    High-pressure is a key feature of deep subsurface environments. High partial pressure of dissolved gasses plays an important role in microbial metabolism, because thermodynamic feasibility of many reactions depends on the concentration of reactants. For gases, this is controlled by their partial pressure, which can exceed 1 MPa at in situ conditions. Therefore, high hydrostatic pressure alone is not sufficient to recreate true deep subsurface in situ conditions, but the partial pressure of dissolved gasses has to be controlled as well. We developed an incubation system that allows for incubations at hydrostatic pressure up to 60 MPa, temperatures up to 120°C, and at high gas partial pressure. The composition and partial pressure of gasses can be manipulated during the experiment. To keep costs low, the system is mainly made from off-the-shelf components with only very few custom-made parts. A flexible and inert PVDF (polyvinylidene fluoride) incubator sleeve, which is almost impermeable for gases, holds the sample and separates it from the pressure fluid. The flexibility of the incubator sleeve allows for sub-sampling of the medium without loss of pressure. Experiments can be run in both static and flow-through mode. The incubation system described here is usable for versatile purposes, not only the incubation of microorganisms and determination of growth rates, but also for chemical degradation or extraction experiments under high gas saturation, e.g., fluid-gas-rock-interactions in relation to carbon dioxide sequestration. As an application of the system we extracted organic compounds from sub-bituminous coal using H(2)O as well as a H(2)O-CO(2) mixture at elevated temperature (90°C) and pressure (5 MPa). Subsamples were taken at different time points during the incubation and analyzed by ion chromatography. Furthermore we demonstrated the applicability of the system for studies of microbial activity, using samples from the Isis mud volcano. We could

  18. A system for incubations at high gas partial pressure

    Directory of Open Access Journals (Sweden)

    Patrick eSauer

    2012-02-01

    Full Text Available High-pressure is a key feature of deep subsurface environments. High partial pressure of dissolved gasses plays an important role in microbial metabolism, because thermodynamic feasibility of many reactions depends on the concentration of reactants. For gases, this is controlled by their partial pressure, which can exceed one MPa at in-situ conditions. Therefore, high hydrostatic pressure alone is not sufficient to recreate true deep subsurface in-situ conditions, but the partial pressure of dissolved gasses has to be controlled as well.We developed an incubation system that allows for incubations at hydrostatic pressure up to 60 MPa, temperatures up to 120° C and at high gas partial pressure. The composition and partial pressure of gasses can be manipulated during the experiment. The system is mainly made from off-the-shelf components with only very few custom-made parts. A flexible and inert PVDF incubator sleeve, which is almost impermeable for gases, holds the sample and separates it from the pressure fluid. The flexibility of the incubator sleeve allows for sub-sampling of the medium without loss of pressure. Experiments can be run in both static and flow through mode. The incubation system described here is usable for versatile purposes, not only the incubation of microorganisms and determination of growth rates, but also for chemical degradation or extraction experiments under high gas saturation, e.g. fluid-gas-rock-interactions in relation to carbon dioxide sequestration.As an application of the system we extracted organic acids from sub-bituminous coal using H2O as well as a H2O-CO2 mixture at elevated temperature (90°C and pressure (5 MPa. Subsamples were taken during the incubation and analysed by ion chromatography. Furthermore we demonstrated the applicability of the system for studies of microbial activity, using samples from the Isis mud volcano. We could detect an increase in sulphate reduction rate upon the addition of

  19. Embedded programmable blood pressure monitoring system

    Science.gov (United States)

    Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk

    2010-02-01

    A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.

  20. Pressure garment design tool to monitor exerted pressures.

    Science.gov (United States)

    Macintyre, Lisa; Ferguson, Rhona

    2013-09-01

    Pressure garments are used in the treatment of hypertrophic scarring following serious burns. The use of pressure garments is believed to hasten the maturation process, reduce pruritus associated with immature hypertrophic scars and prevent the formation of contractures over flexor joints. Pressure garments are normally made to measure for individual patients from elastic fabrics and are worn continuously for up to 2 years or until scar maturation. There are 2 methods of constructing pressure garments. The most common method, called the Reduction Factor method, involves reducing the patient's circumferential measurements by a certain percentage. The second method uses the Laplace Law to calculate the dimensions of pressure garments based on the circumferential measurements of the patient and the tension profile of the fabric. The Laplace Law method is complicated to utilise manually and no design tool is currently available to aid this process. This paper presents the development and suggested use of 2 new pressure garment design tools that will aid pressure garment design using the Reduction Factor and Laplace Law methods. Both tools calculate the pressure garment dimensions and the mean pressure that will be exerted around the body at each measurement point. Monitoring the pressures exerted by pressure garments and noting the clinical outcome would enable clinicians to build an understanding of the implications of particular pressures on scar outcome, maturation times and patient compliance rates. Once the optimum pressure for particular treatments is known, the Laplace Law method described in this paper can be used to deliver those average pressures to all patients. This paper also presents the results of a small scale audit of measurements taken for the fabrication of pressure garments in two UK hospitals. This audit highlights the wide range of pressures that are exerted using the Reduction Factor method and that manual pattern 'smoothing' can dramatically

  1. Organic electronics based pressure sensor towards intracranial pressure monitoring

    Science.gov (United States)

    Rai, Pratyush; Varadan, Vijay K.

    2010-04-01

    The intra-cranial space, which houses the brain, contains cerebrospinal fluid (CSF) that acts as a fluid suspension medium for the brain. The CSF is always in circulation, is secreted in the cranium and is drained out through ducts called epidural veins. The venous drainage system has inherent resistance to the flow. Pressure is developed inside the cranium, which is similar to a rigid compartment. Normally a pressure of 5-15 mm Hg, in excess of atmospheric pressure, is observed at different locations inside the cranium. Increase in Intra-Cranial Pressure (ICP) can be caused by change in CSF volume caused by cerebral tumors, meningitis, by edema of a head injury or diseases related to cerebral atrophy. Hence, efficient ways of monitoring ICP need to be developed. A sensor system and monitoring scheme has been discussed here. The system architecture consists of a membrane less piezoelectric pressure sensitive element, organic thin film transistor (OTFT) based signal transduction, and signal telemetry. The components were fabricated on flexible substrate and have been assembled using flip-chip packaging technology. Material science and fabrication processes, subjective to the device performance, have been discussed. Capability of the device in detecting pressure variation, within the ICP pressure range, is investigated and applicability of measurement scheme to medical conditions has been argued for. Also, applications of such a sensor-OTFT assembly for logic sensor switching and patient specific-secure monitoring system have been discussed.

  2. Endotracheal Tube Cuff Pressure Monitoring in Children

    Directory of Open Access Journals (Sweden)

    V. V. Lazarev

    2012-01-01

    Full Text Available Objective: to estimate tracheal morphological changes in children, by using a device for the continuous monitoring and regulation of endotracheal tube cuff pressure. Subjects and methods. Two groups of children were examined. In Group A comprising 22 children aged 2 months to 16 years, the adequacy of the external control balloon palpation method was estimated to measure endotracheal tube cuff pressure. In Group B consisting of 12 children aged 5 to 18 years on mechanical ventilation for more than 3 days, the efficiency and appropriateness of applying a PressureEasy device for monitoring the pressure in the endotracheal tube cuff were assessed to prevent postintubation tracheal complications. In the latter group, the authors identified a study subgroup (BI of 8 patients where this device was employed and a control group of 4 patients (BII where it was not used. Results. Group A showed that endotracheal tube cuff pressure was 20—30 cm H2O in 31.8% of cases, greater than 30 cm H2O in 36.4%, and lower than 20 cm H2O in 31.8%. Subgroup BI displayed considerably lower macro- and microscopic histological changes than Subgroup BII. Conclusion. Determination of endotracheal tube cuff pressure by palpation of the external control balloon does not reflect its real values. The magnitude of tracheal changes is more intensive if continuous monitoring and regulation of pressure in the endotracheal tube cuff is absent. The PressureEasy device to monitor endotracheal tube cuff pressure permits its variability maintenance at a given level, by mitigating the damaging effect of the cuff on tracheal tissue. Key words: endotracheal tube, cuff, histology, ischemia, prevention, pressure, trachea.

  3. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    Science.gov (United States)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  4. H- Beam Stripping Loss at Background Partial Pressure of Ar

    Institute of Scientific and Technical Information of China (English)

    Hu Chundong; Wang Shaohu; Hu Liqun

    2005-01-01

    It has been observed that H- current could be improved by adding Ar to H2 plasma.But due to a slower pumping speed for Ar with the existing pumping scheme, the tank pressure will increase quickly during the length of a beam pulse. Since H- stripping loss depends on the tank pressure and gas species, part of the H- beam can be converted to H0 and then H0 can be converted into H+ with background H2 and Ar gas thickness. Therefore, the H- beam current,measured by a Faraday cup, situated at a distance L from GG (ground grid), will decrease because it will be converted into a H+ current. This gives a ratio of the Faraday cup net current to the H- beam current before stripping at background partial pressure of Ar.

  5. [Values of mixed venous oxygen saturation and difference of mixed venous-arterial partial pressure of carbon dioxide in monitoring of oxygen metabolism and treatment after open-heart operation].

    Science.gov (United States)

    Pan, Chuanliang; Zhang, Haiying; Liu, Jianping

    2014-10-01

    To explore the clinic values of early goal directed treatment (EGDT) with the target of mixed venous oxygen saturation (SvO₂) and difference of mixed venous-arterial partial pressure of carbon dioxide (Pv-aCO₂) in monitoring of oxygen metabolism and treatment for patients post open-heart operation. A prospective study was conducted. The adult patients admitted to Third People's Hospital of Chengdu from December 2011 to March 2014 with SvO₂2 mmol/L when admitted in intensive care unit (ICU) were selected on whom elective open-heart operation and pulmonary artery catheter examination were done. All patients received EGDT with the target of SvO₂≥0.65 and Pv-aCO₂<6 mmHg (1 mmHg=0.133 kPa) and were divided into three groups by the values of SvO₂and Pv-aCO₂at 6-hour after ICU admission: A group with SvO₂≥0.65 and Pv-aCO₂<6 mmHg, B group with SvO₂≥0.65 and Pv-aCO₂≥6 mmHg, and C group with SvO₂<0.65. Then the changes and prognosis of the patients in different groups were observed. 103 cases were included, 44 in A group, 31 in B group and 28 in C group. The acute physiology and chronic health evaluation II (APACHEII) score in group A were significantly lower than that in group B or C at 6, 24, 48 and 72 hours (T6, T24, T48, T72) of ICU admission (T6: 11.4 ± 5.8 vs. 13.9 ± 5.4, 13.7 ± 6.4; T24: 8.8 ± 3.7 vs. 10.8 ± 4.8, 11.8 ± 5.4; T48: 8.7 ± 4.1 vs. 9.6 ± 4.2, 10.2 ± 5.1; T72: 7.5 ± 3.4 vs. 8.6 ± 2.9, 9.2 ± 4.2, all P<0.05), and the sequential organ failure assessment (SOFA) showed the same tendency (T6: 6.5 ± 4.3 vs. 8.0 ± 3.8, 9.1 ± 4.5; T24: 6.6 ±3.6 vs. 8.6 ± 3.9, 8.5 ± 3.3; T48: 5.2 ± 3.4 vs. 7.0 ± 3.6, 7.6 ± 5.1; T72: 4.6 ± 2.4 vs. 5.8 ± 2.5, 6.8 ± 3.5, all P<0.05). The values of blood lactic acid (mmol/L) in group A and B were significant lower than that in group C at T6, T24, T48 and T72 (T6: 1.60 ± 0.95, 2.20 ± 1.02 vs. 2.55 ± 1.39; T24: 2.26 ± 1.26, 2.70 ± 1.36 vs. 3.34 ± 2.36; T48: 2.01 ± 1.15, 2.17

  6. Monitoring cerebrovascular pressure reactivity with rheoencephalography

    Science.gov (United States)

    Brady, K. M.; Mytar, J. O.; Kibler, K. K.; Easley, R. B.; Koehler, R. C.; Czosnyka, M.; Smielewski, P.; Zweifel, C.; Bodo, M.; Pearce, F. J.; Armonda, R. A.

    2010-04-01

    Determining optimal perfusion pressure for patients with traumatic brain injury can be accomplished by monitoring the pressure reactivity index, or PRx, which requires an intracranial pressure monitor. We hypothesized that pressure reactivity could be quantified using a rheoencephalography index, or REGx. We measured the REGx and PRx as repetitive, low-frequency linear correlation between arterial blood pressure and intracranial pressure (PRx) or arterial blood pressure and REG pulse amplitude (REGx) in a piglet model of progressive hypotension. We compared the PRx and REGx against a gold standard determination of the lower limit of autoregulation using laser-Doppler measurements of cortical red cell flux. The PRx produced an accurate metric of vascular reactivity in this cohort, with area under the receiver-operator characteristic curves of 0.91. REGx was moderately correlated to the PRx, (Spearman r = 0.63, p < 0.0001; Bland-Altman bias-0.13). The area under the receiver-operator curve for the REGx was 0.86. Disagreement occurred at extremes of hypotension.

  7. Application value of end-tidal carbon dioxide partial pressure monitoring in patients with acute cardiogenic pulmonary edema receiving early nonivasive positive pressure ventilation%潮气末二氧化碳分压监测在急性心源性肺水肿患者早期无创正压通气救治中的应用价值

    Institute of Scientific and Technical Information of China (English)

    唐友勇; 王正艳; 杨中卫; 李威; 石明; 邝军

    2016-01-01

    目的 探讨潮气末二氧化碳分压(PETCO2)监测在急性心源性肺水肿患者早期无创正压通气救治中的应用价值.方法 选择2011年2月至2015年5月在湖北医药学院附属东风医院急性心源性肺水肿患者88例,均给予无创正压通气治疗,在通气前后进行血流动力学(心率、收缩压、舒张压、平均动脉压(MAP)、心排血量、心脏指数、心搏指数)、血气指标[pH、动脉血氧分压(PaO2)、二氧化碳分压(PaCO2)]与PETCO2监测,并随访调查预后情况.结果 通气后患者的心排血量、心脏指数与心搏指数值明显降低,与通气前比较差异有统计学意义[(3.3±1.1) L/min比(4.1 ±1.1)L/min、(2.1 ±0.4)L/(min·m2)比(2.6 ±0.6) L/(min·m2)、(25±7)ml/m2比(29±4)ml/m2,P<0.05];心率、收缩压、舒张压与MAP通气前后差异无统计学意义(P>0.05).通气后患者的血气pH、PaO2值较通气前高,而PaCO2值较通气前低,差异有统计学意义[(7.35±0.45)比(7.23±0.24)、(88 ±9) mmHg(1 mmHg =0.133 kPa)比(52±8) mmHg、(39±8)mmHg比(47±9) mmHg,P<0.05].通气后患者的PETCO2为(34±5) mmHg,明显高于通气前的(28±5)mmHg,差异有统计学意义(P<0.05).随访至2016年1月,88例患者中发生联合心血管不良事件12例,发生率为13.6%;Pearson相关分析显示急性心源性肺水肿的预后与通气前的PETCO2、心脏指数、心搏指数及PaCO2存在明显相关性(r=0.443、0.342、0.294、0.331,P<0.05).结论 无创正压通气早期救治急性心源性肺水肿能有效改善心功能与血气状况,对于PETCO2也有明显影响,而PETCO2监测能有效判定病情,预测预后情况.%Objective To investigate the application value of end-tidal carbon dioxide partial pressure (PETCO2) monitoring in patients with acute cardiogenic pulmonary edema receiving early nonivasive positive pressure ventilation.Methods Totally 88 patients confirmed as acute cardiogenic pulmonary edema from February 2011 to May 2015

  8. KSC inventor tests cabin pressure monitor

    Science.gov (United States)

    2000-01-01

    Jan Zysko (left) and Rich Mizell (right) test a Personal Cabin Pressure Altitude Monitor in an altitude chamber at Tyndall Air Force Base in Florida. Zysko invented the pager-sized monitor that alerts wearers of a potentially dangerous or deteriorating cabin pressure altitude condition, which can lead to life- threatening hypoxia. Zysko is chief of the KSC Spaceport Engineering and Technology directorate's data and electronic systems branch. Mizell is a Shuttle processing engineer. The monitor, which has drawn the interest of such organizations as the Federal Aviation Administration for use in commercial airliners and private aircraft, was originally designed to offer Space Shuttle and Space Station crew members added independent notification about any depressurization.

  9. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2002-07-10

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the April 1--June 30, 2002 time period.

  10. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-10-29

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the July 1--September 30, 2003 time period.

  11. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2003-01-30

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the October 1--December 31, 2002 time period.

  12. Development of Pressurized Circulating Fluidized Bed Partial Gasification Module (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    A. Robertson

    2002-09-30

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the July 1-September 30, 2002 time period.

  13. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-07-23

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building bock that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the April 1--June 30, 2003 time period.

  14. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  15. DEVELOPMENT OF PRESSURIZED CIRCULATING FLUIDIZED BED PARTIAL GASIFICATION MODULE (PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-03-29

    Foster Wheeler Development Corporation is working under DOE contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% while producing near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The unique aspect of the process is that it utilizes a pressurized circulating fluidized bed partial gasifier and does not attempt to consume the coal in a single step. To convert all the coal to syngas in a single step requires extremely high temperatures ({approx}2500 to 2800 F) that melt and vaporize the coal and essentially drive all coal ash contaminants into the syngas. Since these contaminants can be corrosive to power generating equipment, the syngas must be cooled to near room temperature to enable a series of chemical processes to clean the syngas. Foster Wheeler's process operates at much lower temperatures that control/minimize the release of contaminants; this eliminates/minimizes the need for the expensive, complicated syngas heat exchangers and chemical cleanup systems typical of high temperature gasification. By performing the gasification in a circulating bed, a significant amount of syngas can still be produced despite the reduced temperature and the circulating bed allows easy scale up to large size plants. Rather than air, it can also operate with oxygen to facilitate

  16. Ambulatory Blood Pressure Monitoring in the Elderly

    OpenAIRE

    Juan Diego Mediavilla García; Fernando Jaén Águila; Celia Fernández Torres; Blas Gil Extremera; Juan Jiménez Alonso

    2012-01-01

    The incidence of hypertension is high in the elderly and is present in 2/3 of the patients older than 65 years. Prevalence can reach 90% in patients older than 80 years. The presence of isolated systolic hypertension (ISH) is characteristic of this population. However, the prevalence of hypertension by ambulatory blood pressure monitoring (ABPM) is not well known. In this study, we analyzed the special characteristics of hypertension in this population, giving special emphasis on ABPM readings.

  17. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    OpenAIRE

    Turner, J. Rick; Viera, Anthony J.; Shimbo, Daichi

    2014-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings ca...

  18. Monitoring of Intracranial Pressure During Intracranial Endoscopy

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar

    2013-08-01

    Full Text Available Background: Intracranial endoscopy is a minimum invasive procedure, which reduces trauma to the brain, is cost-effective, and carries a shortened hospital stay with an improved postoperative outcome. Objective: To monitor intracranial pressure changes during intracranial endoscopy among children and adults under general anesthesia/sedation, and to compare the intracranial pressure changes between children and adults receiving general anesthesia and among adults receiving general anesthesia and sedation. Methods: The present cross-sectional study was conducted in one of the tertiary care hospitals of Lucknow. This was carried out in the department of neurosurgery from January 2008 to December 2008. Patients who were not fit for general anesthesia received local anesthesia under sedation. Patients participating in the study were divided into three groups. Intracranial pressure was recorded at specific intervals. Parametric data were subjected to statistical analysis using a student\\s t test. Result: A total of 70 patients were undergoing intracranial endoscopy under general anesthesia during the study period. In both groups A and B, intracranial pressure increases the maximum during inflation of the balloon. In group C, all the variations in ICP were found to be statistically significant. In the comparison of intracranial pressure changes between groups A and B, no significant difference was found. All correlations in the comparison of groups B and C were found to be statistically significant (p< 0.001. Conclusion: There is a need for continuous intraoperative monitoring of ICP intracranial endoscopy, because ICP increases in various stages of the procedure, which can be detrimental to the perfusion of the brain. [Arch Clin Exp Surg 2013; 2(4.000: 240-245

  19. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  20. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  1. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model

    OpenAIRE

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota,Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    Objective The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. Methods The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Results Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.0...

  2. The relation between in vivo ethylene production and oxygen partial pressure

    NARCIS (Netherlands)

    Sanders, M.G.; Wild, de H.P.J.

    2003-01-01

    Modelling in vivo ethylene production rate in relation to O2 partial pressure was used to improve understanding of enzyme kinetics of 1-aminocyclopropane-1-carboxylate oxidase (ACC oxidase). Tomato fruit were stored in an extensive range of O2 partial pressures at 8, 13 and 18 °C. Ethylene

  3. Influence of the oxygen partial pressure on the phase evolution during Bi-2212 wire melt processing

    CERN Document Server

    C. Scheuerlein; M.O. Rikel; J. Kadar; C. Doerrer; M. Di Michiel; A. Ballarino; L. Bottura; J. Jiang; F. Kametani; E.E. Hellstrom; D.C. Larbalestier; 10.1109/TASC.2016.2533574

    2016-01-01

    We have studied the influence of the oxygen partial pressure pO2 up to 5.5 bar on the phase changes that occur during melt processing of a state-of-the-art Bi-2212 multifilamentary wire. Phase changes have been monitored in situ by high energy synchrotron X-ray diffraction (XRD). We found that the stability of Bi-2212 phase is reduced with increasing pO2. For pO2>1 bar a significant amount of Bi-2212 phase decomposes upon heating in the range 400 to 650 °C. The extent of decomposition strongly increases with increasing pO2, and at pO2=5.5 bar Bi-2212 decomposes completely in the solid state. Textured Bi-2212 can be formed during solidification when pO2 is reduced to 0.45 bar when the precursor is molten. Since the formation of current limiting second phases is very sensitive to pO2 when it exceeds 1 bar, we recommend to reduce the oxygen partial pressure below the commonly used pO2=1 bar, in order to increase the pO2 margins and to make the overpressure process more robust.

  4. 呼气末二氧化碳分压监测在手术后患者麻醉复苏中的应用%APPLICATION OF PARTIAL PRESSURE MONITORING OF CARBON DIOXIDE IN ENDEXPIRATORY ;GAS IN PATIENTS AFTER SURGERY ANESTHESIA RESUSCITATION

    Institute of Scientific and Technical Information of China (English)

    赵艳青; 郑丽娟; 齐燕; 杨玉新

    2016-01-01

    Objective To discuss the application effect on end- tidal carbon dioxide partial pressure (end tidal carbon dioxide partial pressure,PetCO2 )monitoring patients after surgery anesthesia recovery.Meth-ods Patients choosed from July 2013 to August 2015 in author's hospital,200 cases of surgery and anes-thesia after entering the recovery room,divided into observation group and control group,100 cases in each group.The observation group was monitored with anesthetized PETCO2 in recovery period,that was ob-served in patients with PETCO2 squiggles and values,and routine monitoring was performed on ECG, blood pressure,oxygen saturation and body temperature;while the control group was only for routine mo-nitoring.Results The times in the observation group of patients with apnea,respiratory depression and catheter displacement were much shorter than the control group,after the PACU 0.5-1 hour,the number of cases of retreat extubation was to more than the control group,the differences were statistically signifi-cance (P <0.05).Conclusion PETCO2 monitor patients recovery after surgery anesthetic effect are obvi-ous,it is worth promoting and clinical applications.%目的:探讨呼气末二氧化碳分压(carbon dioxide tension and arterial pressure,PetCO2)监测在手术后患者麻醉复苏中的应用效果。方法选取2013年7月—2015年8月在该院接受手术治疗并在术后进入麻醉复苏室的患者200例,分为观察组和对照组,每组100例,观察组进行麻醉复苏期的 PetCO2监测,即观察患者 PetCO2波形曲线和数值,并进行常规的监测心电图、血压、血氧饱和度和体温;对照组只进行常规监测。结果观察组发现患者出现呼吸暂停、呼吸抑制和导管位移的时间远远要短于对照组,入PACU 0.5~1h 后拔管例数多于对照组,以上差异均具有统计学意义(P <0.05)。结论PETCO2监测在手术后患者麻醉复苏中的作用很明显,值得大力推广和临床应用。

  5. NDE and Stress Monitoring on Composite Overwrapped Pressure Vessels Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Damage caused by composite overwrapped pressure vessels (COPVs) failure can be catastrophic. Thus, monitoring condition and stress in the composite overwrap,...

  6. [Reproducibility of arterial pressure measured in the ELSA-Brasil with 24-hour pressure monitoring].

    Science.gov (United States)

    Nascimento, Larissa Rangel; Molina, Maria del Carmen Bisi; Faria, Carolina Perim; Cunha, Roberto de Sá; Mill, José Geraldo

    2013-06-01

    To determine the reproducibility of casual arterial pressure measurement and to confirm pressure diagnosis by monitoring of participants in the ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health). Casual blood pressure was measured with an oscilometric device. A sub-sample of participants (N = 255) from Espírito Santo state (Southeastern Brazil) was reevaluated using the same methodology following one to ten weeks and, in addition, underwent arterial blood pressure monitoring. Diagnosis of hypertension used cut off points of 140/90 mmHg for casual pressure and 130/80 mmHg for arterial blood pressure monitoring. White coat hypertension was defined as the presence of hypertension in casual blood pressure and normal arterial blood pressure monitoring, and converse findings characterized masked hypertension. Data are from 230 participants that on the two occasions were free from antihypertensive medication (N1 = 153) or under the same antihypertensive regimen (N2 = 77). Normotension was confirmed by arterial blood pressure monitoring in 120 out of 134 participants of the N1 group. In N2, blood pressure control was confirmed by arterial blood pressure monitoring in 43 of 54 participants with controlled hypertension per casual blood pressure. Overall diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was 78% (kappa = 0.44). In the N1 group, six subjects (4%) presented white coat hypertension, and 23 subjects (25%) presented with masked hypertension. Diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was moderate. The rigorous standardization of casual blood pressure measurement adopted in the ELSA-Brasil study was able to reduce white coat hypertension. The high frequency of masked hypertension may suggest that pressure values obtained by arterial blood pressure monitoring indicate an elevated degree of stress at work.

  7. Extending helium partial pressure measurement technology to JET DTE2 and ITER

    Science.gov (United States)

    Klepper, C. C.; Biewer, T. M.; Kruezi, U.; Vartanian, S.; Douai, D.; Hillis, D. L.; Marcus, C.

    2016-11-01

    The detection limit for helium (He) partial pressure monitoring via the Penning discharge optical emission diagnostic, mainly used for tokamak divertor effluent gas analysis, is shown here to be possible for He concentrations down to 0.1% in predominantly deuterium effluents. This result from a dedicated laboratory study means that the technique can now be extended to intrinsically (non-injected) He produced as fusion reaction ash in deuterium-tritium experiments. The paper also examines threshold ionization mass spectroscopy as a potential backup to the optical technique, but finds that further development is needed to attain with plasma pulse-relevant response times. Both these studies are presented in the context of continuing development of plasma pulse-resolving, residual gas analysis for the upcoming JET deuterium-tritium campaign (DTE2) and for ITER.

  8. Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

    OpenAIRE

    Farve Daneshvar Fard; Sahar Moghimi; Reza Lotfi

    2014-01-01

    Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer prevention. Materials and Methods The monitoring system consists of 64 pressure and 64 temperature sensors on...

  9. Measurement of hepatic tissue hypoxia using near infrared spectroscopy: comparison with hepatic vein oxygen partial pressure.

    Science.gov (United States)

    El-Desoky, A E; Jiao, L R; Havlik, R; Habib, N; Davidson, B R; Seifalian, A M

    2000-01-01

    Hepatic hypoxia occurs during liver surgery and transplantation. The critical level associated with irreversible hepatocellular damage is unknown. Measurement of hepatic tissue oxygenation and hepatic vein oxygen partial pressure (HVPO(2)) reflects oxygen supply and consumption. Near infrared spectroscopy (NIRS) can be used to monitor hepatic oxyhaemoglobin (HbO(2)), deoxyhaemoglobin (Hb) and cytochrome oxidase (Cyt Ox) oxidation. This study compared regional hepatic tissue oxygenation (HbO(2), Hb and Cyt Ox) using NIRS with HVPO(2). The use of tissue oxygenation measured by NIRS and HVPO(2) as indicators of hepatic tissue hypoxia was also investigated. Large Landrace pigs (n = 5) underwent laparotomy and liver exposure. Systemic and hepatic haemodynamics were monitored continuously. NIRS probes were placed on the liver to record continuously HbO(2), Hb and Cyt Ox. Graded hypoxaemia was achieved by stepwise reduction of the fraction of inspired oxygen (FiO(2)) from 30% (baseline) to 4%. A significant decrease in hepatic arterial blood flow and total hepatic blood flow was seen with severe hypoxaemia while there was no significant change to portal vein blood flow. Oxygen partial pressures in the hepatic artery, portal vein and hepatic vein decreased progressively with all grades of hypoxaemia. There was an immediate reduction of hepatic HbO(2) and simultaneous increase in hepatic Hb with all grades of hypoxaemia. Hepatic Cyt Ox was reduced significantly only with FiO(2) oxygenation parameters measured by NIRS and HVPO(2). HVPO(2) measurement did not predict the reduction in intracellular tissue oxygenation demonstrated by NIRS with a decrease of Cyt Ox oxidation. In conclusion there was a good correlation between the tissue oxygenation parameters measured by NIRS and HVPO(2). However, the reduction of intracellular oxygenation found with severe hypoxaemia was demonstrated only by NIRS.

  10. Potential hydrogen and oxygen partial pressures in legacy plutonium oxide packages at Oak Ridge

    Energy Technology Data Exchange (ETDEWEB)

    Veirs, Douglas K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-07-07

    An approach to estimate the maximum hydrogen and oxygen partial pressures within sealed containers is described and applied to a set of packages containing high-purity plutonium dioxide. The approach uses experimentally determined maximum hydrogen and oxygen partial pressures and scales the experimentally determined pressures to the relevant packaged material properties. The important material properties are the specific wattage and specific surface area (SSA). Important results from the experimental determination of maximum partial pressures are (1) the ratio of hydrogen to oxygen is stoichiometric, and (2) the maximum pressures increase with increasing initial rates of production. The material properties that influence the rates are the material specific wattage and the SSA. The unusual properties of these materials, high specific wattage and high SSA, result in higher predicted maximum pressures than typical plutonium dioxide in storage. The pressures are well within the deflagration range for mixtures of hydrogen and oxygen.

  11. Feasibility of measuring dissolved carbon dioxide based on head space partial pressures

    Science.gov (United States)

    Watten, B.J.; Boyd, C.E.; Schwartz, M.F.; Summerfelt, S.T.; Brazil, B.L.

    2004-01-01

    We describe an instrument prototype that measures dissolved carbon dioxide (DC) without need for standard wetted probe membranes or titration. DC is calculated using Henry's Law, water temperature, and the steady-state partial pressure of carbon dioxide that develops within the instrument's vertical gas-liquid contacting chamber. Gas-phase partial pressures were determined with either an infrared detector (ID) or by measuring voltage developed by a pH electrode immersed in an isolated sodium carbonate solution (SC) sparged with recirculated head space gas. Calculated DC concentrations were compared with those obtained by titration over a range of DC (2, 4, 8, 12, 16, 20, 24, and 28mg/l), total alkalinity (35, 120, and 250mg/l as CaCO3), total dissolved gas pressure (-178 to 120 mmHg), and dissolved oxygen concentrations (7, 14, and 18 mg/l). Statistically significant (P method was 1.3%. In a third test series, a single ID was coupled with four replicate head space units so as to permit sequential monitoring (15 min intervals) of a common water source. Here, appropriate gas samples were secured using a series of solenoid valves (1.6 mm bore) activated by a time-based controller. This system configuration reduced the capital cost per sample site from US$ 2695 to 876. Absolute error averaged 2.9, 3.1, 3.7, and 2.7 mg/ l for replicates 1-4 (N = 36) during a 21-day test period (DC range, 36-40 mg/l). The ID meter was then modified so as to provide for DO as well as DC measurements across components of an intensive fish production system. ?? 2003 Elsevier B.V. All rights reserved.

  12. Changes in Cerebral Partial Oxygen Pressure and Cerebrovascular Reactivity During Intracranial Pressure Plateau Waves.

    Science.gov (United States)

    Lang, Erhard W; Kasprowicz, Magdalena; Smielewski, Peter; Pickard, John; Czosnyka, Marek

    2015-08-01

    Plateau waves in intracranial pressure (ICP) are frequently recorded in neuro intensive care and are not yet fully understood. To further investigate this phenomenon, we analyzed partial pressure of cerebral oxygen (pbtO2) and a moving correlation coefficient between ICP and mean arterial blood pressure (ABP), called PRx, along with the cerebral oxygen reactivity index (ORx), which is a moving correlation coefficient between cerebral perfusion pressure (CPP) and pbtO2 in an observational study. We analyzed 55 plateau waves in 20 patients after severe traumatic brain injury. We calculated ABP, ABP pulse amplitude (ampABP), ICP, CPP, pbtO2, heart rate (HR), ICP pulse amplitude (ampICP), PRx, and ORx, before, during, and after each plateau wave. The analysis of variance with Bonferroni post hoc test was used to compare the differences in the variables before, during, and after the plateau wave. We considered all plateau waves, even in the same patient, independent because they are separated by long intervals. We found increases for ICP and ampICP according to our operational definitions for plateau waves. PRx increased significantly (p = 0.00026), CPP (p waves. ABP, ampABP, and HR remained unchanged. PRx during the plateau was higher than before the onset of wave in 40 cases (73 %) with no differences in baseline parameters for those with negative and positive ΔPRx (difference during and after). ORx showed an increase during and a decrease after the plateau waves, however, not statistically significant. PbtO2 overshoot after the wave occurred in 35 times (64 %), the mean difference was 4.9 ± 4.6 Hg (mean ± SD), and we found no difference in baseline parameters between those who overshoot and those who did not overshoot. Arterial blood pressure remains stable in ICP plateau waves, while cerebral autoregulatory indices show distinct changes, which indicate cerebrovascular reactivity impairment at the top of the wave. PbtO2 decreases during the waves and may

  13. The Design of Partial Discharge On-Line Monitoring System for XLPE Power Cable

    OpenAIRE

    Chen Rui-Long; Qian Yong; Ye Hai-Feng; Sheng Ge-Hao; Jiang Xiu-Chen

    2013-01-01

    Partial discharge detection is an important means to assess the situation of XLPE power cable’s insulation. This study has developed an on-line monitoring system which applies to the medium voltage XLPE cable on partial discharge, described its working principle, components of hardware, software designing and program implementation in details. Through monitoring the partial discharge signal in grounding lines of the XLPE cable’s shield, the system integrated assess the situation of XLPE cable...

  14. Electric conductivity for laboratory and field monitoring of induced partial saturation (IPS) in sands

    Science.gov (United States)

    Kazemiroodsari, Hadi

    Liquefaction is loss of shear strength in fully saturated loose sands caused by build-up of excess pore water pressure, during moderate to large earthquakes, leading to catastrophic failures of structures. Currently used liquefaction mitigation measures are often costly and cannot be applied at sites with existing structures. An innovative, practical, and cost effective liquefaction mitigation technique titled "Induced Partial Saturation" (IPS) was developed by researchers at Northeastern University. The IPS technique is based on injection of sodium percarbonate solution into fully saturated liquefaction susceptible sand. Sodium percarbonate dissolves in water and breaks down into sodium and carbonate ions and hydrogen peroxide which generates oxygen gas bubbles. Oxygen gas bubbles become trapped in sand pores and therefore decrease the degree of saturation of the sand, increase the compressibility of the soil, thus reduce its potential for liquefaction. The implementation of IPS required the development and validation of a monitoring and evaluation technique that would help ensure that the sands are indeed partially saturated. This dissertation focuses on this aspect of the IPS research. The monitoring system developed was based on using electric conductivity fundamentals and probes to detect the transport of chemical solution, calculate degree of saturation of sand, and determine the final zone of partial saturation created by IPS. To understand the fundamentals of electric conductivity, laboratory bench-top tests were conducted using electric conductivity probes and small specimens of Ottawa sand. Bench-top tests were used to study rate of generation of gas bubbles due to reaction of sodium percarbonate solution in sand, and to confirm a theory based on which degree of saturation were calculated. In addition to bench-top tests, electric conductivity probes were used in a relatively large sand specimen prepared in a specially manufactured glass tank. IPS was

  15. A new dynamic method for measuring hydrogen partial pressure in molten aluminum alloy

    Directory of Open Access Journals (Sweden)

    Sun Qian

    2011-02-01

    Full Text Available Hydrogen partial pressure is an important parameter to calculate hydrogen concentration levels in molten aluminum alloy. A new dynamic method for measuring hydrogen partial pressure in molten aluminum alloy is studied. Dynamic and rapid measurement is realized through changing the volume of the vacuum chamber and calculating the pressure difference ΔP between the theoretical and measured pressures in the vacuum chamber. Positive ΔP indicates hydrogen transmits from melt to vacuum chamber and negative ΔP means the reverse. When ΔP is equal to zero, hydrogen transmitted from both sides reached a state of dynamical equilibrium and the pressure in the vacuum chamber is equal to the hydrogen partial pressure in the molten aluminum alloy. Compared with other existing measuring methods, the new method can significantly shorten the testing time and reduce measuring cost.

  16. Biomedical System for Monitoring Pressure Ulcer Development

    OpenAIRE

    Wang, Frank Tinghwa

    2013-01-01

    Pressure ulcers (PU) are one of the leading health concerns among patients living in long-term care facilities and are a common occurrence in hospitals. In the United States alone, over 2.5 million patients will suffer from pressure ulcers each year, and over 60,000 patients will die due to pressure ulcer related complications. The cost to treat pressure ulcers including hospitalization costs is also prohibitively expensive; just in the United States alone it is estimated that $9.2-15.6 Billi...

  17. Bulk YBa2Cu3O(x) superconductors through pressurized partial melt growth processing

    Science.gov (United States)

    Hu, S.; Hojaji, H.; Barkatt, A.; Boroomand, M.; Hung, M.; Buechele, A. C.; Thorpe, A. N.; Davis, D. D.; Alterescu, S.

    1992-01-01

    A novel pressurized partial melt growth process has been developed for producing large pieces of bulk Y-Ba-Cu-O superconductors. During long-time partial melt growth stage, an additional driving force for solidification is obtained by using pressurized oxygen gas. The microstructure and superconducting properties of the resulting samples were investigated. It was found that this new technique can eliminate porosity and inhomogeneity, promote large-scale grain-texturing, and improve interdomain coupling as well.

  18. Partial molar volume of L-Valine in water under high pressure

    Science.gov (United States)

    Sawamura, Seiji

    2013-06-01

    Partial molar volume of L-valine in water was estimated up to 400 MPa from pressure coefficient of the solubility of the solute and molar volume of solid valine. The former was measured in a previous paper and the latter was measured in this article using a piston-cylinder typed cell. The partial molar volume increased with pressure and a maximum was observed around 250 MPa. It was compared with other amino acids.

  19. Clinical evaluation of a new epidural pressure monitor.

    Science.gov (United States)

    Czech, T; Korn, A; Reinprecht, A; Schramm, W; Kimla, T; Spiss, C K

    1993-01-01

    Comparative measuring of epidural pressure using the Spiegelberg probe 1 and ventricular fluid pressure was carried out in 15 neurosurgical intensive-care patients. Deviations in both directions were established, with a trend toward overestimating ventricular pressure in epidural pressure measuring (r = 0.77). Individual pulsations, spontaneous wave courses and therapy-induced pressure changes were reflected without delays. There were no complications observed with probe implantation periods for up to 6 days. The system has been shown to be mechanically stable and easy to implant. We believe the device to be fit for trend monitoring of intracranial pressure. As with other epidural pressure monitoring systems, false assessments of ventricular pressure may lead to wrong decisions as to required therapy.

  20. Oxidation of SiC/BN/SiC Composites in Reduced Oxygen Partial Pressures

    Science.gov (United States)

    Opila, Elizabeth J.; Boyd, Meredith

    2010-01-01

    SiC fiber-reinforced SiC composites with a BN interphase are proposed for use as leading edge structures of hypersonic vehicles. The durability of these materials under hypersonic flight conditions is therefore of interest. Thermogravimetric analysis was used to characterize the oxidation kinetics of both the constituent fibers and composite coupons at four temperatures: 816, 1149, 1343, and 1538 C (1500, 2100, 2450, and 2800 F) and in oxygen partial pressures between 5% and 0.1% (balance argon) at 1 atm total pressure. One edge of the coupons was ground off so the effects of oxygen ingress into the composite could be monitored by post-test SEM and EDS. Additional characterization of the oxidation products was conducted by XPS and TOF-SIMS. Under most conditions, the BN oxidized rapidly, leading to the formation of borosilicate glass. Rapid initial oxidation followed by volatilization of boria lead to protective oxide formation and further oxidation was slow. At 1538C in 5% oxygen, both the fibers and coupons exhibited borosilicate glass formation and bubbling. At 1538C in 0.1% oxygen, active oxidation of both the fibers and the composites was observed leading to rapid SiC degradation. BN oxidation at 1538C in 0.1% oxygen was not significant.

  1. Blood Pressure Home Monitoring in Hypertensive Patients Attending ...

    African Journals Online (AJOL)

    Purpose: To investigate the effect of home monitoring of blood pressure (HMBP) on adherence ... these factors, non compliance to therapy was ... completed by pharmacy students (n = 15) to test ..... training on proper documentation of their BP.

  2. Home monitoring of blood pressure: patients' perception and role of ...

    African Journals Online (AJOL)

    Home monitoring of blood pressure: patients' perception and role of the ... One hundred patients with doctor-diagnosed hypertension were recruited into the study. ... A majority of participants suffer from anxiety (68 %) in response to high blood ...

  3. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Science.gov (United States)

    2010-04-01

    ... pressure with a catheter placed transcervically into the uterine cavity. The device is used to monitor intensity, duration, and frequency of uterine contractions during labor. This generic type of device...

  4. Wearable Beat to Beat Blood Pressure Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during space missions. The wearable beat-to-beat blood pressure...

  5. Noninvasive automatic blood pressure monitoring does not attenuate nighttime hypotension. Evidence from 24 h intraarterial blood pressure monitoring.

    Science.gov (United States)

    Villani, A; Parati, G; Groppelli, A; Omboni, S; Di Rienzo, M; Mancia, G

    1992-10-01

    Automatic ambulatory blood pressure monitoring makes use of repeated cuff inflations throughout the day and night. This may interfere with the cardiovascular effects of sleep and thus alter the 24 h blood pressure profile. The possibility that intermittent automatic blood pressure measurements prevent nocturnal hypotension was examined in 17 mild or moderate essential hypertensive patients in whom blood pressure was recorded intraarterially for 48 h by the Oxford technique. During the first or the second 24 h period, blood pressure was also monitored noninvasively by the SpaceLabs (Redmond, WA) 5300 (n = 10) and by the Sandoz Pressure System SPS 1558 (Lavanchy Electronique, Prilly, Switzerland) (n = 7) devices, automatic measurements being performed at 15 min intervals during the day and at 30 min intervals during the night. Separate computer analysis of 24 h intraarterial tracings obtained in absence and in concomitance of contralateral automatic blood pressure monitoring showed that the occurrence of automatic measurements had not interfered with the day-night intraarterial blood pressure and heart rate profiles. Thus the frequent cuff inflations that characterize automatic blood pressure monitoring do not attenuate nighttime hypotension and bradycardia. This finding supports use of the noninvasive approach in assessing blood pressure profiles.

  6. abdominal pressure monitoring in varying intra- abdominal ...

    African Journals Online (AJOL)

    TV measurements were achieved using a manual manometer system with a Foley ... relatedness. As the test subjects were organised into related groups, we used intra- .... air before instillation of fluid, contractility of the muscular stomach wall, an exit ... TV techniques both have utility in the clinical setting, with TG pressure.

  7. Role of ambulatory blood pressure monitoring in resistant hypertension.

    Science.gov (United States)

    Grassi, Guido; Bombelli, Michele; Seravalle, Gino; Brambilla, Gianmaria; Dell'oro, Raffaella; Mancia, Giuseppe

    2013-06-01

    Ambulatory blood pressure monitoring has gained growing popularity in the diagnosis and treatment of essential hypertension for several reasons, such as the lack of the so-called white-coat effect, the greater reproducibility as compared with clinic blood pressure, the ability to provide information on blood pressure phenomena of prognostic value and the closer relationship with the risk of cardiovascular morbidity and mortality. All the above-mentioned main features of ambulatory blood pressure monitoring are also true for resistant hypertension. In addition, however, in resistant hypertension, blood pressure monitoring allows one to precisely define the diagnosis of this clinical condition, by excluding the presence of white-coat hypertension, which is responsible for a consistent number of "false" resistant hypertensive cases. The approach also allows one to define the patterns of blood pressure variability in this clinical condition, as well as its relationships with target organ damage. Finally, it allows one to assess the effects of therapeutic interventions, such as renal nerves ablation, aimed at improving blood pressure control in this hypertensive state. The present paper will critically review the main features of ambulatory blood pressure monitoring in resistant hypertension, with particular emphasis on the diagnosis and treatment of this high-risk hypertensive state.

  8. A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring.

    Science.gov (United States)

    Boutry, Clementine M; Nguyen, Amanda; Lawal, Qudus Omotayo; Chortos, Alex; Rondeau-Gagné, Simon; Bao, Zhenan

    2015-11-18

    An array of highly sensitive pressure sensors entirely made of biodegradable materials is presented, designed as a single-use flexible patch for application in cardiovascular monitoring. The high sensitivity in combination with fast response time is unprecedented when compared to recent reports on biodegradable pressure sensors (sensitivity three orders of magnitude higher), as illustrated by pulse wave velocity measurements, toward hypertension detection.

  9. Effects of oxygen partial pressure on Li-air battery performance

    Science.gov (United States)

    Kwon, Hyuk Jae; Lee, Heung Chan; Ko, Jeongsik; Jung, In Sun; Lee, Hyun Chul; Lee, Hyunpyo; Kim, Mokwon; Lee, Dong Joon; Kim, Hyunjin; Kim, Tae Young; Im, Dongmin

    2017-10-01

    For application in electric vehicles (EVs), the Li-air battery system needs an air intake system to supply dry oxygen at controlled concentration and feeding rate as the cathode active material. To facilitate the design of such air intake systems, we have investigated the effects of oxygen partial pressure (≤1 atm) on the performance of the Li-air cell, which has not been systematically examined. The amounts of consumed O2 and evolved CO2 from the Li-air cell are measured with a custom in situ differential electrochemical gas chromatography-mass spectrometry (DEGC-MS). The amounts of consumed O2 suggest that the oxygen partial pressure does not affect the reaction mechanism during discharge, and the two-electron reaction occurs under all test conditions. On the other hand, the charging behavior varies by the oxygen partial pressure. The highest O2 evolution ratio is attained under 70% O2, along with the lowest CO2 evolution. The cell cycle life also peaks at 70% O2 condition. Overall, an oxygen partial pressure of about 0.5-0.7 atm maximizes the Li-air cell capacity and stability at 1 atm condition. The findings here indicate that the appropriate oxygen partial pressure can be a key factor when developing practical Li-air battery systems.

  10. Monitoring temperature and pressure over surfaces using sensitive paints

    Science.gov (United States)

    Guerrero-Viramontes, J. Ascención; Moreno Hernández, David; Mendoza Santoyo, Fernando; Morán Loza, José Miguel; García Arreola, Alicia

    2007-03-01

    Two techniques for monitoring temperature and pressure variations over surfaces using sensitive paints are presented. The analysis is done by the acquisition of a set of images of the surface under analysis. The surface is painted by a paint called Pressure Sensitive Paint (PSP) for pressure measurements and Temperature Sensitive Paints (TSP) for temperature measurements. These kinds of paints are deposited over the surface under analysis. The recent experimental advances in calibration process are presented in this paper.

  11. Wearable Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2015-01-01

    Linea Research Corporation has developed a wearable noninvasive monitor that provides continuous blood pressure and heart rate measurements in extreme environments. Designed to monitor the physiological effects of astronauts' prolonged exposure to reduced-gravity environments as well as the effectiveness of various countermeasures, the device offers wireless connectivity to allow transfer of both real-time and historical data. It can be modified to monitor the health status of astronaut crew members during extravehicular missions.

  12. A thermophile under pressure: Transcriptional analysis of the response of Caldicellulosiruptor saccharolyticus to different H2 partial pressures

    NARCIS (Netherlands)

    Bielen, A.A.M.; Verhaart, M.R.A.; Vanfossen, A.L.; Blumer-Schuette, S.E.; Stams, A.J.M.; Oost, van der J.; Kelly, R.M.; Kengen, S.W.M.

    2013-01-01

    Increased hydrogen (H2) levels are known to inhibit H2 formation in Caldicellulosiruptor saccharolyticus. To investigate this organism's strategy for dealing with elevated H2 levels the effect of the hydrogen partial pressure (PH2) on fermentation performance was studied by growing cultures under

  13. A thermophile under pressure: Transcriptional analysis of the response of Caldicellulosiruptor saccharolyticus to different H2 partial pressures

    NARCIS (Netherlands)

    Bielen, A.A.M.; Verhaart, M.R.A.; Vanfossen, A.L.; Blumer-Schuette, S.E.; Stams, A.J.M.; Oost, van der J.; Kelly, R.M.; Kengen, S.W.M.

    2013-01-01

    Increased hydrogen (H2) levels are known to inhibit H2 formation in Caldicellulosiruptor saccharolyticus. To investigate this organism's strategy for dealing with elevated H2 levels the effect of the hydrogen partial pressure (PH2) on fermentation performance was studied by growing cultures under hi

  14. Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

    Directory of Open Access Journals (Sweden)

    Farve Daneshvar Fard

    2014-08-01

    Full Text Available Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer prevention. Materials and Methods The monitoring system consists of 64 pressure and 64 temperature sensors on a 40×50 cm2 sheet. Pressure and temperature data and the corresponding maps were displayed on a computer in real-time. Risk assessment could be performed by monitoring and recording absolute pressure and temperature values, as well as deviations over time. Furthermore, a posture detection procedure was proposed for sitting posture identification. Information about the patient’s movement history may help caregivers make informed decisions about the patient’s repositioning and ulcer prevention strategies. Results Steady temporal behaviour of the designed system and repeatability of the measurements were evaluated using several particular tests. The results illustrated that the system could be utilized for continuous monitoring of interface pressure and temperature for pressure ulcer prevention. Furthermore, the proposed method for detecting sitting posture was verified using a statistical analysis. Conclusion A continuous time pressure and temperature monitoring system was presented in this study. This system may be suited for pressure ulcer prevention given its feasibility for simultaneous monitoring of pressure and temperature and alarming options. Furthermore, a method for detecting different sitting postures was proposed and verified. Pressure ulcers in wheelchair-bound patients may be prevented using this sitting posture detection method.

  15. Oscillometric continuous blood pressure sensing for wearable health monitoring system

    CERN Document Server

    Gelao, Gennaro; Passaro, Vittorio M N; Perri, Anna Gina

    2015-01-01

    In this paper we present an acquisition chain for the measurement of blood arterial pressure based on the oscillometric method. This method does not suffer from any limitation as the well-known auscultatory method and it is suited for wearable health monitoring systems. The device uses a pressure sensor whose signal is filtered, digitalized and analyzed by a microcontroller. Local analysis allows the evaluation of the systolic and diastolic pressure values which can be used for local alarms, data collection and remote monitoring.

  16. The Design of Partial Discharge On-Line Monitoring System for XLPE Power Cable

    Directory of Open Access Journals (Sweden)

    Chen Rui-Long

    2013-09-01

    Full Text Available Partial discharge detection is an important means to assess the situation of XLPE power cable’s insulation. This study has developed an on-line monitoring system which applies to the medium voltage XLPE cable on partial discharge, described its working principle, components of hardware, software designing and program implementation in details. Through monitoring the partial discharge signal in grounding lines of the XLPE cable’s shield, the system integrated assess the situation of XLPE cable’s insulation. The results of running show that the system is stable and reliable.

  17. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  18. Brain tissue partial pressure of oxygen predicts the outcome of severe traumatic brain injury under mild hypothermia treatment

    Directory of Open Access Journals (Sweden)

    Sun H

    2016-08-01

    Full Text Available Hongtao Sun,1,* Maohua Zheng,2,* Yanmin Wang,1 Yunfeng Diao,1 Wanyong Zhao,1 Zhengjun Wei1 1Sixth Department of Neurosurgery, Affiliated Hospital of Logistics University of People’s Armed Police Force, Tianjin, 2Department of Neurosurgery, The First Hospital of Lanzhou University, Lanzhou, People’s Republic of China *These authors contributed equally to this work Objective: The aim of this study was to investigate the clinical significance and changes of brain tissue partial pressure of oxygen (PbtO2 in the course of mild hypothermia treatment (MHT for treating severe traumatic brain injury (sTBI. Methods: There were 68 cases with sTBI undergoing MHT. PbtO2, intracranial pressure (ICP, jugular venous oxygen saturation (SjvO2, and cerebral perfusion pressure (CPP were continuously monitored, and clinical outcomes were evaluated using the Glasgow Outcome Scale score. Results: Of 68 patients with sTBI, PbtO2, SjvO2, and CPP were obviously increased, but decreased ICP level was observed throughout the MHT. PbtO2 and ICP were negatively linearly correlated, while there was a positive linear correlation between PbtO2 and SjvO2. Monitoring CPP and SjvO2 was performed under normal circumstances, and a large proportion of patients were detected with low PbtO2. Decreased PbtO2 was also found after MHT. Conclusion: Continuous PbtO2 monitoring could be introduced to evaluate the condition of regional cerebral oxygen metabolism, thereby guiding the clinical treatment and predicting the outcome. Keywords: severe traumatic brain injury, hypothermia, brain tissue partial pressure of oxygen, therapy

  19. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P pressures......, but surprisingly normal arterial blood pressure during the nighttime, and the circadian variation in blood pressure and HR is diminished, probably because of an almost unaltered cardiac output during the 24 hours. These results may reflect a major defect in the ability of optimal regulation of blood pressure...

  20. Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures?

    Science.gov (United States)

    Nassar, Boulos S; Schmidt, Gregory A

    2017-06-01

    The arterial partial pressure of carbon dioxide (PaCO2) is an important parameter in critically ill, mechanically ventilated patients. To limit invasive procedures or for more continuous monitoring of PaCO2, clinicians often rely on venous blood gases, capnography, or transcutaneous monitoring. Each of these has advantages and limitations. Central venous Pco2 allows accurate estimation of PaCO2, differing from it by an amount described by the Fick principle. As long as cardiac output is relatively normal, central venous Pco2 exceeds the arterial value by approximately 4 mm Hg. In contrast, peripheral venous Pco2 is a poor predictor of PaCO2, and we do not recommend using peripheral venous Pco2 in this manner. Capnography offers measurement of the end-tidal Pco2 (PetCO2), a value that is close to PaCO2 when the lung is healthy. It has the advantage of being noninvasive and continuously available. In mechanically ventilated patients with lung disease, however, PetCO2 often differs from PaCO2, sometimes by a large degree, often seriously underestimating the arterial value. Dependence of PetCO2 on alveolar dead space and ventilator expiratory time limits its value to predict PaCO2. When lung function or ventilator settings change, PetCO2 and PaCO2 can vary in different directions, producing further uncertainty. Transcutaneous Pco2 measurement has become practical and reliable. It is promising for judging steady state values for PaCO2 unless there is overt vasoconstriction of the skin. Moreover, it can be useful in conditions where capnography fails (high-frequency ventilation) or where arterial blood gas analysis is burdensome (clinic or home management of mechanical ventilation).

  1. Structural phase diagram and equilibrium oxygen partial pressure of YBa2Cu3O6+x

    DEFF Research Database (Denmark)

    Andersen, N.H.; Lebech, B.; Poulsen, H.F.

    1990-01-01

    An experimental technique by which in-situ gas volumetric measurements are carried out on a neutron powder diffractometer, is presented and used for simultaneous studies of oxygen equilibrium partial pressure and the structural phase diagram of YBa2Cu3O6 + x. Experimental data was collected under...... of the ordering of oxygen. Oxygen equilibrium partial pressure shows significant variations with temperature and concentration which indicate that x = 0.15 and x = 0.92 are minimum and maximum oxygen concentrations. Measurements of oxygen in-diffusion flow show relaxation type behaviour: View the MathML source...

  2. Effects of hydrogen partial pressure on autotrophic growth and product formation of Acetobacterium woodii.

    Science.gov (United States)

    Kantzow, Christina; Weuster-Botz, Dirk

    2016-08-01

    Low aqueous solubility of the gases for autotrophic fermentations (e.g., hydrogen gas) results in low productivities in bioreactors. A frequently suggested approach to overcome mass transfer limitation is to increase the solubility of the limiting gas in the reaction medium by increasing the partial pressure in the gas phase. An increased inlet hydrogen partial pressure of up to 2.1 bar (total pressure of 3.5 bar) was applied for the autotrophic conversion of hydrogen and carbon dioxide with Acetobacterium woodii in a batch-operated stirred-tank bioreactor with continuous gas supply. Compared to the autotrophic batch process with an inlet hydrogen partial pressure of 0.4 bar (total pressure of 1.0 bar) the final acetate concentration after 3.1 days was reduced to 50 % (29.2 g L(-1) compared to 59.3 g L(-1)), but the final formate concentration was increased by a factor of 18 (7.3 g L(-1) compared to 0.4 g L(-1)). Applying recombinant A. woodii strains overexpressing either genes for enzymes in the methyl branch of the Wood-Ljungdahl pathway or the genes phosphotransacetylase and acetate kinase at an inlet hydrogen partial pressure of 1.4 bar reduced the final formate concentration by up to 40 % and increased the final dry cell mass and acetate concentrations compared to the wild type strain. Solely the overexpression of the two genes for ATP regeneration at the end of the Wood-Ljungdahl pathway resulted in an initial switch off of formate production at increased hydrogen partial pressure until the maximum of the hydrogen uptake rate was reached.

  3. Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; van Goudoever, Jeroen; de Beaumont, Edouard M F H; Truijen, Jasper; Kim, Yu-Sok; Immink, Rogier V; Jöbsis, Dorothea A; Hollmann, Markus W; Lahpor, Jaap R; de Mol, Bas A J M; van Lieshout, Johannes J

    2012-05-01

    If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.

  4. Laboratory monitoring of P-waves in partially saturated sand

    Science.gov (United States)

    Barrière, J.; Bordes, C.; Brito, D.; Sénéchal, P.; Perroud, H.

    2011-12-01

    Seismic data depends on a variety of hydrogeological properties of the prospected porous media such as porosity, permeability and fluid saturation. We have performed a laboratory experiment in the kiloHertz range in order to analyze the role of partial saturation on direct propagating P-waves phase velocity and attenuation. The experiment consists of a sand-filled tank 107 cm x 34 cm x 35cm equipped with accelerometers and water capacitance probes. The P-waves seismic propagation is generated by hitting a steel ball on a granite plate on the one lateral side of the container. Several imbibition/drainage cycles are performed between the water residual saturation and the gas residual saturation. The laboratory seismic data are processed by two Continuous Wavelet Transforms using one real mother wavelet (Mexican hat) and one complex (Morlet) to recover velocity and attenuation as a function of frequency. Phase velocity of direct P-wave decreases with an increase of water content and is quite consistent with the low frequency limit of the Biot's theory both for imbibition and drainage. The interpretation of the P-waves attenuation needs to go beyond the macroscopic fluid flow of Biot's theory and to introduce a viscoelastic contribution linked to the grain to grain overall losses which are described by a constant Q-model. A strong hysteresis between imbibition and drainage is observed and explained by introducing an effective permeability depending on water and gas relative permeabilities (Van Genuchten model).

  5. Optimizing the physical ergonomics indices for the use of partial pressure suits.

    Science.gov (United States)

    Ding, Li; Li, Xianxue; Hedge, Alan; Hu, Huimin; Feathers, David; Qin, Zhifeng; Xiao, Huajun; Xue, Lihao; Zhou, Qianxiang

    2015-03-01

    This study developed an ergonomic evaluation system for the design of high-altitude partial pressure suits (PPSs). A total of twenty-one Chinese males participated in the experiment which tested three types of ergonomics indices (manipulative mission, operational reach and operational strength) were studied using a three-dimensional video-based motion capture system, a target-pointing board, a hand dynamometer, and a step-tread apparatus. In total, 36 ergonomics indices were evaluated and optimized using regression and fitting analysis. Some indices that were found to be linearly related and redundant were removed from the study. An optimal ergonomics index system was established that can be used to conveniently and quickly evaluate the performance of different pressurized/non-pressurized suit designs. The resulting ergonomics index system will provide a theoretical basis and practical guidance for mission planners, suit designers and engineers to design equipment for human use, and to aid in assessing partial pressure suits.

  6. Noncontact Monitoring of Respiration by Dynamic Air-Pressure Sensor.

    Science.gov (United States)

    Takarada, Tohru; Asada, Tetsunosuke; Sumi, Yoshihisa; Higuchi, Yoshinori

    2015-01-01

    We have previously reported that a dynamic air-pressure sensor system allows respiratory status to be visually monitored for patients in minimally clothed condition. The dynamic air-pressure sensor measures vital information using changes in air pressure. To utilize this device in the field, we must clarify the influence of clothing conditions on measurement. The present study evaluated use of the dynamic air-pressure sensor system as a respiratory monitor that can reliably detect change in breathing patterns irrespective of clothing. Twelve healthy volunteers reclined on a dental chair positioned horizontally with the sensor pad for measuring air-pressure signals corresponding to respiration placed on the seat back of the dental chair in the central lumbar region. Respiratory measurements were taken under 2 conditions: (a) thinly clothed (subject lying directly on the sensor pad); and (b) thickly clothed (subject lying on the sensor pad covered with a pressure-reducing sheet). Air-pressure signals were recorded and time integration values for air pressure during each expiration were calculated. This information was compared with expiratory tidal volume measured simultaneously by a respirometer connected to the subject via face mask. The dynamic air-pressure sensor was able to receive the signal corresponding to respiration regardless of clothing conditions. A strong correlation was identified between expiratory tidal volume and time integration values for air pressure during each expiration for all subjects under both clothing conditions (0.840-0.988 for the thinly clothed condition and 0.867-0.992 for the thickly clothed condition). These results show that the dynamic air-pressure sensor is useful for monitoring respiratory physiology irrespective of clothing.

  7. Effects of oxygen partial pressure and annealing temperature on the formation of sputtered tungsten oxide films

    OpenAIRE

    2002-01-01

    Thin films of tungsten oxide were deposited on silicon substrates using reactive radio frequency sputtering. The structure of the films strongly depends on the conditions of deposition and post-treatment. Important issues are the influences of oxygen pressure during deposition and annealing temperature on the morphology. Atomic force microscopy and scanning electron microscopy revealed that films were formed by grains. The sample deposited with an Ar:O(2) partial pressure ratio of 1: 1 showed...

  8. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors

    Directory of Open Access Journals (Sweden)

    Bruno Castro

    2016-08-01

    Full Text Available Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  9. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.

    Science.gov (United States)

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-08-10

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

  10. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors

    Science.gov (United States)

    Castro, Bruno; Clerice, Guilherme; Ramos, Caio; Andreoli, André; Baptista, Fabricio; Campos, Fernando; Ulson, José

    2016-01-01

    Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique. PMID:27517931

  11. Continuous monitoring of barometric pressure in deep mines

    Energy Technology Data Exchange (ETDEWEB)

    Trutwin, W.; Mironowicz, W.; Wasilewski, S.; Krawczyk, J. [Research and Development Centre for Electrical Engineering and Automation in Mining EMAG, Katowice (Poland)

    2005-07-01

    Barometric pressure and its variation in deep underground workings have a considerable effect on ventilation conditions. Pressure changes which create transient states of air flow and air parameters in workings are especially significant. Experiments have shown that pressure changes have a remarkable effect on air parameters at mine workings. Continuous monitoring of the barometric pressure on the surface of mines allows for the detection of changes in pressure which influence alternations of pressure in the underground areas of mines. Important factors are the internal disturbances of pressure within a mine ventilation system due to variable conditions of fan operation and the operation of a winding machine where a mine cage moving in a shaft causes piston like disturbances. Local transient disturbances caused by temporary opening/closing of air stoppings due to personnel or underground transport traffic are of importance. The results of over two years of observations of barometric pressure and its influence on pressure variation in underground mine workings are presented. The observations were possible through the installation of pressure sensors at selected points of the downcast shaft in a mine. Of interest are the observations of the transient states of pressure and other air parameters caused by emergency fan stoppage, movement of a mine cage and changes due to the opening of air stoppings. Data acquired during experiments of opening and closing air stoppings were used for the validation of a flow model in a long working. 13 refs., 15 figs.

  12. Intracranial pressure monitoring in severe traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Apetrei Al. Cosmin

    2014-06-01

    Full Text Available Intracranial pressure monitoring seems to be an indispensable stage in management of severe traumatic brain injured patient. Since 2009, this technique completes our trauma protocol. The study has been carried out from 2011 to 2013 in Prof. Dr. N. Oblu hospital in Iasi. There have been included in the study patients with severe craniocerebral trauma, who had traumatic brain lesions CT detected and Glasgow score between 3 and 8. The age ranged from 16 to 60, an average of 35.5 years old. 50% of the studied cases had a favorable outcome. Diagrams associated to this category of patients showed increases in intracranial pressure above normal values but without repeated values above 50 mm Hg. Most of those patients had a good evolution under medical treatment. Monitoring intracranial pressure is an extremely useful stage in treating intracranial high pressure in traumatology and it should be included in the equipment of any intensive therapy section caring traumatic patients

  13. Partial Discharge Measurements in HV Rotating Machines in Dependence on Pressure of Coolant

    Directory of Open Access Journals (Sweden)

    I. Kršňák

    2002-01-01

    Full Text Available The influence of the pressure of the coolant used in high voltage rotating machines on partial discharges occurring in stator insulation is discussed in this paper. The first part deals with a theoretical analysis of the topic. The second part deals with the results obtained on a real generator in industrial conditions. Finally, theoretical assumptions and obtained results are compared.

  14. Effects of elevated CO2 partial pressure and temperature on the coccolithophore Syracosphaera pulchra

    NARCIS (Netherlands)

    Fiorini, S.; Middelburg, J.J.; Gattuso, J.-P.

    2011-01-01

    The effects of elevated partial pressure of CO2 (pCO2) and temperature on the cocco - lithophore Syracosphaera pulchra were investigated in isolation and in combination. Both the diploid and the haploid life stages were studied. Batch cultures were grown under 4 conditions: 400 μatm and 19°C; 400

  15. Partial alignment and measurement of residual dipolar couplings of proteins under high hydrostatic pressure.

    Science.gov (United States)

    Fu, Yinan; Wand, A Joshua

    2013-08-01

    High-pressure NMR spectroscopy has emerged as a complementary approach for investigating various structural and thermodynamic properties of macromolecules. Noticeably absent from the array of experimental restraints that have been employed to characterize protein structures at high hydrostatic pressure is the residual dipolar coupling, which requires the partial alignment of the macromolecule of interest. Here we examine five alignment media that are commonly used at ambient pressure for this purpose. We find that the spontaneous alignment of Pf1 phage, d(GpG) and a C12E5/n-hexnanol mixture in a magnetic field is preserved under high hydrostatic pressure. However, DMPC/DHPC bicelles and collagen gel are found to be unsuitable. Evidence is presented to demonstrate that pressure-induced structural changes can be identified using the residual dipolar coupling.

  16. Partial alignment and measurement of residual dipolar couplings of proteins under high hydrostatic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yinan; Wand, A. Joshua, E-mail: wand@mail.med.upenn.edu [University of Pennsylvania, Department of Biochemistry and Biophysics, Johnson Research Foundation (United States)

    2013-08-15

    High-pressure NMR spectroscopy has emerged as a complementary approach for investigating various structural and thermodynamic properties of macromolecules. Noticeably absent from the array of experimental restraints that have been employed to characterize protein structures at high hydrostatic pressure is the residual dipolar coupling, which requires the partial alignment of the macromolecule of interest. Here we examine five alignment media that are commonly used at ambient pressure for this purpose. We find that the spontaneous alignment of Pf1 phage, d(GpG) and a C12E5/n-hexnanol mixture in a magnetic field is preserved under high hydrostatic pressure. However, DMPC/DHPC bicelles and collagen gel are found to be unsuitable. Evidence is presented to demonstrate that pressure-induced structural changes can be identified using the residual dipolar coupling.

  17. Self-monitoring of blood pressure during pregnancy

    DEFF Research Database (Denmark)

    Lihme, Frederikke F; Madsen, Mette E; Lykke, Jacob A

    2017-01-01

    OBJECTIVE: The aim of this study was to assess the feasibility of self-monitoring of blood pressure with a semiautomatic device in pregnant women. PARTICIPANTS AND METHODS: Women attending routine obstetrical ultrasound scanning were invited to participate. The hospital staff initially demonstrated...... arterial blood pressure (MAP) and were compared using the paired sample t-test. Mean values and differences of systolic and diastolic pressure were plotted in Bland-Altman plots to test the agreement of the measurements. Finally, a mean evaluation score was calculated. RESULTS: One hundred pregnant women...

  18. [Device to assess in-socket pressure distribution for partial foot amputation].

    Science.gov (United States)

    Alvarez-Camacho, Michelín; Urrusti, José Luis; Acero, María Del Carmen; Galván Duque-Gastélum, Carlos; Rodríguez-Reyes, Gerardo; Mendoza-Cruz, Felipe

    2014-07-01

    A device for dynamic acquisition and distribution analysis of in-socket pressure for patients with partial foot amputation is presented in this work. By using the developed system, we measured and generated pressure distribution graphs, obtained maximal pressure, and calculated pressure-time integral (PTI) of three subjects with partial foot amputation and of a group of Healthy subjects (Hs) (n = 10). Average maximal pressure in the healthy group was 19.4 ± 4.11 PSI, while for the three amputated patients, this was 27.8 ± 1.38, 17.6 ± 1.15, 29.10 ± 3.9 PSI, respectively. Maximal pressure-time integral for healthy subjects was 11.56 ± 2.83 PSI*s, and for study subjects was 19.54 ± 1.9, 12.35 ± 1.48, and 13.17 ± 1.31 PSI*s, respectively. The results of the control group agree with those previously reported in the literature. The pressure distribution pattern showed clear differences between study subjects and those of the control group; these graphs allowed us to identify the pressure in regions-of-interest that could be critical, such as surgical scars. The system presented in this work will aid to assess the effectiveness with which prosthetic systems distribute load, given that the formation of ulcers is highly linked to the pressure exercised at the point of contact; in addition, these results will help to investigate the comfort perception of the prosthesis, a factor directly influenced by the stump's pressure distribution.

  19. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P pressure and HR from daytime......Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P pressures...

  20. [THE REMOTE MONITORING OF ARTERIAL PRESSURE AND RATE OF HEARTBEATS].

    Science.gov (United States)

    Shalkovskii, A G; Kuptsov, S M; Berseneva, E A

    2015-01-01

    The article considers issues of necessity of development and implementation of remote monitoring of arterial blood pressure and rate of heartbeats as a mean of enhancing quality of medical care of patients. The main characteristics of development of specialized automated system as an integral component of the project is considered too.

  1. On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer

    Institute of Scientific and Technical Information of China (English)

    LIN Du; JIANG Lei; LI Fuqi; ZHU Deheng; TAN Kexiong; WU Chengqi; JIN Xianhe; WANG Changchang; CHENG T. C.

    2005-01-01

    This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modularized and exchangeable components. The system software is a power equipment monitoring and diagnostic system, which is based on the component object model, and was developed for monitoring multiple parameters in multiple power supply systems. The statistical characteristics of PDs in power transformers were studied using 7 experimental models for simulating PDs in transformers and 3 models for simulating interfering discharges in air. The discharge features were analyzed using a 3-D pattern chart with a three-layer back-propagation artificial neural network used to recognize the patterns. The results show that PDs in air and oil can be distinguished. The model can be used for interference rejection on-line monitoring of partial discharge in transformers.

  2. Significant practice pattern variations associated with intracranial pressure monitoring.

    Science.gov (United States)

    Olson, DaiWai M; Lewis, Lisa S; Bader, Mary Kay; Bautista, Cynthia; Malloy, Rachel; Riemen, Kristina E; McNett, Molly M

    2013-08-01

    The purpose of this study was to describe nursing practice in the care of patients with intracranial pressure monitoring. Although standards for care of such patients have been established, there continue to be variations in the nursing practice. This was an observational study in which data were collected from 28 nurse-patient dyads at 16 different hospitals across the United States. Each dyad was observed for 2 hours; nursing actions and patient responses including intracranial pressure readings were documented. Differences in the care of patients with intracranial pressure monitoring were prevalent. Variations in practice were prompted by healthcare provider prescriptions as well as nursing decisions. Prescriptions and interventions were often not supported by the available scientific evidence. For more insights from the authors, see Supplemental Digital Content 1, at http://links.lww.com/JNN/A7.

  3. Vibration pore water pressure characteristics of saturated fine sand under partially drained condition

    Institute of Scientific and Technical Information of China (English)

    王炳辉; 陈国兴

    2008-01-01

    Vibration pore water pressure characteristics of saturated fine sand under partially drained condition were investigated through stress-controlled cyclic triaxial tests employed varied fine content of samples and loading frequency. In order to simulate the partially drained condition, one-way drainage for sample was implemented when cyclic loading was applied. The results show that the vibration pore water pressure’s response leads the axial stress and axial strain responses, and is lagged behind or simultaneous with axial strain-rate’s response for all samples in this research. In addition, the satisfactory linear relationship between vibration pore water pressure amplitude and axial strain-rate amplitude is also obtained. It means that the direct cause of vibration pore water pressure generation under partially drained conditions is not the axial stress or axial strain but the axial strain-rate. The lag-phase between pore water pressure and axial strain-rate increases with the increase of the fine content or the loading frequency.

  4. Electrical machines monitoring using partial discharges; Monitorizacion de maquinas electricas mediante descargas parciales

    Energy Technology Data Exchange (ETDEWEB)

    Cano, J. C.; Rodriguez Ruiz, S.

    2006-07-01

    Electrical Machines Monitoring is a philosophy that is being more and more accepted in maintenance, the application of these techniques has a lot of advantages as the life evaluation non-intrusively and the detection and evolution evaluation of defects. this paper presents the monitoring of electrical machines using the Partial Discharges technique, which allow the evaluation of insulation of Electrical Machines. Real Cases are included in the paper as samples in which this techniques has been useful to detecting defects. (Author)

  5. Field on monitoring partial discharges in rotating machines; Experiencias en campo en monitorizacion de descargas parciales en maquinas rotativas

    Energy Technology Data Exchange (ETDEWEB)

    Cano Gonzalez, J. C.; Blokhintsev, I.

    2010-07-01

    The partial discharge monitoring is now an accepted technique in the market, however there are different measurement solutions. Equipment manufacturers partial discharge using different equipment, different measurement frequencies, different sensors and different solutions to noise.

  6. Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring.

    Science.gov (United States)

    Dave, Jaydev K; Halldorsdottir, Valgerdur G; Eisenbrey, John R; Merton, Daniel A; Liu, Ji-Bin; Zhou, Jian-Hua; Wang, Hsin-Kai; Park, Suhyun; Dianis, Scott; Chalek, Carl L; Lin, Feng; Thomenius, Kai E; Brown, Daniel B; Forsberg, Flemming

    2012-10-01

    The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (f(transmit): 2.5 MHz, f(receive): 1.25 MHz) was used to collect radiofrequency data at 10-40% incident acoustic power levels with 2-4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from -0.82 to -0.94 and from -0.70 to -0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: -0.71 to -0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring.

  7. Comparison of femoral and auricular arterial blood pressure monitoring in pigs.

    Science.gov (United States)

    Bass, Louise M E; Yu, Dao-Yi; Cullen, Len K

    2009-09-01

    To compare arterial blood pressure measurements obtained from the femoral and auricular arteries in anaesthetized pigs. Prospective experimental study. Fifteen female Large White pigs were used weighing 21.3 +/- 2.3 kg. The pigs were anaesthetized with tiletamine/zolazepam and xylazine administered intramuscularly, and anaesthesia maintained with isoflurane delivered in oxygen/nitrogen. Arterial oxygen partial pressures were maintained between 11.3 and 13.3 kPa and PaCO(2) between 4.6 and 6.0 kPa. Monitoring included electrocardiogram, capnography and invasive blood pressure. The auricular and femoral arteries were catheterized for continuous systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) measurements. Measurements were recorded every 15 minutes. Statistical analysis involved a Bland-Altman plot analysis. The mean difference +/- confidence intervals between the femoral and the auricular arterial diastolic, systolic and mean blood pressure measurements during hypotension were 2 +/- 7, 2 +/- 5 and 2 +/- 5 mmHg respectively. In conditions of normotension mean difference +/- confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 +/- 5, 3 +/- 7 and 4 +/- 4 mmHg respectively. In conditions of increased arterial blood pressure, mean difference +/- confidence intervals, of femoral and auricular arterial blood pressure measurements of diastolic, systolic and mean blood pressure were 4 +/- 5, 3 +/- 8 and 4 +/- 4 mmHg respectively. Auricular artery catheterization is easier and quicker to perform. Pressure measurements from the auricular artery compared well with the femoral artery. We found that auricular arterial blood pressures were similar to femoral arterial values under the conditions of this experiment. We did not test extremes of blood pressure or significant alterations in body temperature.

  8. Comparison of noninvasive blood pressure monitoring with invasive arterial pressure monitoring in medical ICU patients with septic shock.

    Science.gov (United States)

    Riley, Leonard E; Chen, Guoqing John; Latham, Heath E

    2017-08-01

    In the critically ill, the insertion of peripheral arterial catheters to monitor hemodynamics is a low-risk procedure, but carries the potential for complications. This study was designed to compare invasive and noninvasive blood pressure measurements in patients with septic shock in a medical ICU. We carried out a prospective observational study of patients admitted with septic shock and a radially inserted peripheral arterial catheter in the medical ICU with 31 adult patients who underwent four pairs of simultaneous noninvasive and invasive blood pressure measurements (124 comparisons), with the invasive blood pressure taken as the gold standard. Agreements between invasive and noninvasive blood pressure methods were assessed using Bland-Altman analysis, and clinical significance was determined by the European Society of Hypertension criteria. In all patients, noninvasive systolic (P=0.0385), diastolic (Parterial pressures (Ppressure measurements did not correlate clinically according to the European Society of Hypertension criteria. In our patients admitted to the medical ICU with septic shock, noninvasive blood pressure monitoring did not clinically correlate with invasive blood pressure measurements.

  9. Heart-rate monitoring by air pressure and causal analysis

    Science.gov (United States)

    Tsuchiya, Naoki; Nakajima, Hiroshi; Hata, Yutaka

    2011-06-01

    Among lots of vital signals, heart-rate (HR) is an important index for diagnose human's health condition. For instance, HR provides an early stage of cardiac disease, autonomic nerve behavior, and so forth. However, currently, HR is measured only in medical checkups and clinical diagnosis during the rested state by using electrocardiograph (ECG). Thus, some serious cardiac events in daily life could be lost. Therefore, a continuous HR monitoring during 24 hours is desired. Considering the use in daily life, the monitoring should be noninvasive and low intrusive. Thus, in this paper, an HR monitoring in sleep by using air pressure sensors is proposed. The HR monitoring is realized by employing the causal analysis among air pressure and HR. The causality is described by employing fuzzy logic. According to the experiment on 7 males at age 22-25 (23 on average), the correlation coefficient against ECG is 0.73-0.97 (0.85 on average). In addition, the cause-effect structure for HR monitoring is arranged by employing causal decomposition, and the arranged causality is applied to HR monitoring in a setting posture. According to the additional experiment on 6 males, the correlation coefficient is 0.66-0.86 (0.76 on average). Therefore, the proposed method is suggested to have enough accuracy and robustness for some daily use cases.

  10. Suppression of diamagnetism by neutrals pressure in partially ionized, high-beta plasma

    Science.gov (United States)

    Shinohara, Shunjiro; Kuwahara, Daisuke; Yano, Kazuki; Fruchtman, Amnon

    2016-12-01

    Suppression of diamagnetism in a partially ionized plasma with high beta was experimentally investigated by the use of Langmuir and Hall sensor probes, focusing on a neutrals pressure effect. The plasma beta, which is the ratio of plasma to vacuum magnetic pressures, varied from ˜1% to >100% while the magnetic field varied from ˜120 G to ˜1 G. Here, a uniform magnetized argon plasma was operated mostly in an inductive mode, using a helicon plasma source of the Large Helicon Plasma Device [S. Shinohara et al., Phys. Plasmas 16, 057104 (2009)] with a diameter of 738 mm and an axial length of 4860 mm. Electron density varied from 5 × 1015 m-3 to power of 7 MHz and ˜3.5 kW, respectively. The observed magnetic field reduction rate, a decrease of the magnetic field divided by the vacuum one, was up to 18%. However, in a certain parameter regime, where the product of ion and electron Hall terms is a key parameter, the measured diamagnetic effect was smaller than that expected by the plasma beta. This suppressed diamagnetism is explained by the neutrals pressure replacing magnetic pressure in balancing plasma pressure. Diamagnetism is weakened if neutrals pressure is comparable to the plasma pressure and if the coupling of plasma and neutrals pressures by ion-neutral collisions is strong enough.

  11. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    Pystupa T.D.

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  12. Ambulatory blood pressure monitoring during pregnancy with a new, small, easily concealed monitor.

    Science.gov (United States)

    Tape, T G; Rayburn, W F; Bremer, K D; Schnoor, T A

    1994-12-01

    Before establishing the utility of ambulatory blood pressure monitoring during pregnancy, we evaluated the accuracy of a small, easily concealed monitor. The 59 normotensive pregnant patients were between 13 and 26 gestational weeks. For each monitor reading, two trained observers independently and simultaneously recorded blood pressures using a mercury manometer connected to the monitor cuff. Seven readings in three positions (sitting upright, semirecumbent, standing) were performed on each patient. Averaged differences between the observers' and monitor readings varied from -2.2 to -0.9 mm Hg (systolic) and from -2.8 to -0.6 (fifth-phase diastolic), indicating slight but clinically unimportant overestimation by the monitor. Correlations between averaged observers' readings and the monitor ranged from 0.79 to 0.92 (systolic) and from 0.85 to 0.92 (fifth-phase diastolic). Overall, the observers agreed with the monitor within 5 mm Hg on 94% of systolic readings and 99% of fifth-phase diastolic readings. There was no statistically significant difference in accuracy with changes in body position. We conclude that this small, quiet, noninvasive device accurately determined blood pressures during pregnancy.

  13. Online Monitoring of Composite Overwrapped Pressure Vessels (COPV)

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; Figueiredo, Joana; Faria, Hugo

    2015-01-01

    Composite overwrapped pressure vessels (COPV) have been increasingly pointed to as the most effective solution for high pressure storage of liquid and gaseous fluids. Reasonably high stiffness-to-weight ratios make them suitable for both static and mobile applications. However, higher operating...... pressures are sought continuously, to get higher energy densities in such storage systems, and safety aspects become critical. Thus, reliable design and test procedures are required to reduce the risks of undesired and unpredicted failures. An in-service health monitoring system may contribute to a better...... product development, design and optimization, as well as to minimize the risks and improve the public acceptance. Within the scope of developing different COPV models for a wide range of operating pressures and applications, optical fiber Bragg grating (FBG) sensors were embedded in the liner...

  14. [Intraoperative monitoring of oxygen tissue pressure: Applications in vascular neurosurgery].

    Science.gov (United States)

    Arikan, Fuat; Vilalta, Jordi; Torne, Ramon; Chocron, Ivette; Rodriguez-Tesouro, Ana; Sahuquillo, Juan

    2014-01-01

    Ischemic lesions related to surgical procedures are a major cause of postoperative morbidity in patients with cerebral vascular disease. There are different systems of neuromonitoring to detect intraoperative ischemic events, including intraoperative monitoring of oxygen tissue pressure (PtiO2). The aim of this article was to describe, through the discussion of 4 cases, the usefulness of intraoperative PtiO2 monitoring during vascular neurosurgery. In presenting these cases, we demonstrate that monitoring PtiO2 is a reliable way to detect early ischemic events during surgical procedures. Continuous monitoring of PtiO2 in an area at risk allows the surgeon to resolve the cause of the ischemic event before it evolves to an established cerebral infarction. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  15. In vivo near real time imaging of oxygen partial pressures in the glass catfish (Kryptopterus bichirris)

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2012-01-01

    Soc for experimental Biol Annual Meeting - Salzburg 2012 Morten Bo S. Svendsen (University of Copenhagen, Denmark) and John F. Steffensen (University of Copenhagen, Denmark) By injecting 1 IJm microspheres containing an oxygen-dependent phosphorescent dye into the vascular system and tissue...... of the transparent glass catfish (Kryptopterus bichirris), it is possible to measure near realtime oxygen partial pressure in vivo. We used a commercially-available digital single-lens reflex camera mounted with an optical long pass filter (II = 490 nm) and excited the phosphorescent dye in the microspheres inside...... of the microspheres and a recovery period from the anaesthesia, in vivo oxygen partial pressure can be determined by just taking a picture of the live fish exposed to blue light. As no electrodes or sensors are attached, the method allows a wide range of experiments investigating in vivo oxygen levels under different...

  16. Oxidation of C/SiC Composites at Reduced Oxygen Partial Pressures

    Science.gov (United States)

    Opila, Elizabeth J.; Serra, Jessica

    2009-01-01

    Carbon-fiber reinforced SiC (C/SiC) composites are proposed for leading edge applications of hypersonic vehicles due to the superior strength of carbon fibers at high temperatures (greater than 1500 C). However, the vulnerability of the carbon fibers in C/SiC to oxidation over a wide range of temperatures remains a problem. Previous oxidation studies of C/SiC have mainly been conducted in air or oxygen, so that the oxidation behavior of C/SiC at reduced oxygen partial pressures of the hypersonic flight regime are less well understood. In this study, both carbon fibers and C/SiC composites were oxidized over a wide range of temperatures and oxygen partial pressures to facilitate the understanding and modeling of C/SiC oxidation kinetics for hypersonic flight conditions.

  17. Kinetics and rate-limiting mechanisms of dolomitedissolution at various CO2 partial pressures

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Techniques of rotating-disk and catalyst were used in investigating the kinetics of dolo-mite dissolution in flowing CO2-H2O system. Experiments run in the solutions equilibrated withvarious CO2 partial pressures (PCO2) from 30 to 100000 Pa. It shows that dissolution rates ofdolomite are related with rotating speeds at conditions far from equilibrium. This was explained bymodified diffusion boundary layer (DBL) model. In addition, the dissolution rates increase after ad-dition of carbonic anhydrase (CA) to solutions, where the CA catalyzes CO2 conversion. However,great differences occur among various CO2 partial pressures. The experimental observations givea conclusion that the modified DBL model enables one to predict dissolution rates and their be-haviour at various PCO2 with satisfactory precision at least far from equilibrium.

  18. Patient repositioning and pressure ulcer risk--monitoring interface pressures of at-risk patients.

    Science.gov (United States)

    Peterson, Matthew J; Gravenstein, Nikolaus; Schwab, Wilhelm K; van Oostrom, Johannes H; Caruso, Lawrence J

    2013-01-01

    Repositioning patients regularly to prevent pressure ulcers and reduce interface pressures is the standard of care, yet prior work has found that standard repositioning does not relieve all areas of at-risk tissue in nondisabled subjects. To determine whether this holds true for high-risk patients, we assessed the effectiveness of routine repositioning in relieving at-risk tissue of the perisacral area using interface pressure mapping. Bedridden patients at risk for pressure ulcer formation (n = 23, Braden score pressures recorded every 30 s while they received routine repositioning care for 4-6 h. All participants had specific skin areas (206 +/- 182 cm(2)) that exceeded elevated pressure thresholds for >95% of the observation period. Thirteen participants were observed in three distinct positions (supine, turned left, turned right), and all had specific skin areas (166 +/- 184 cm(2)) that exceeded pressure thresholds for >95% of the observation period. At-risk patients have skin areas that are likely always at risk throughout their hospital stay despite repositioning. Healthcare providers are unaware of the actual tissue-relieving effectiveness (or lack thereof) of their repositioning interventions, which may partially explain why pressure ulcer mitigation strategies are not always successful. Relieving at-risk tissue is a necessary part of pressure ulcer prevention, but the repositioning practice itself needs improvement.

  19. Oxygen supply in aquatic ectotherms: partial pressure and solubility together explain biodiversity and size patterns.

    Science.gov (United States)

    Verberk, Wilco C E P; Bilton, David T; Calosi, Piero; Spicer, John I

    2011-08-01

    Aquatic ectotherms face the continuous challenge of capturing sufficient oxygen from their environment as the diffusion rate of oxygen in water is 3 x 10(5) times lower than in air. Despite the recognized importance of oxygen in shaping aquatic communities, consensus on what drives environmental oxygen availability is lacking. Physiologists emphasize oxygen partial pressure, while ecologists emphasize oxygen solubility, traditionally expressing oxygen in terms of concentrations. To resolve the question of whether partial pressure or solubility limits oxygen supply in nature, we return to first principles and derive an index of oxygen supply from Fick's classic first law of diffusion. This oxygen supply index (OSI) incorporates both partial pressure and solubility. Our OSI successfully explains published patterns in body size and species across environmental clines linked to differences in oxygen partial pressure (altitude, organic pollution) or oxygen solubility (temperature and salinity). Moreover, the OSI was more accurately and consistently related to these ecological patterns than other measures of oxygen (oxygen saturation, dissolved oxygen concentration, biochemical oxygen demand concentrations) and similarly outperformed temperature and altitude, which covaried with these environmental clines. Intriguingly, by incorporating gas diffusion rates, it becomes clear that actually more oxygen is available to an organism in warmer habitats where lower oxygen concentrations would suggest the reverse. Under our model, the observed reductions in aerobic performance in warmer habitats do not arise from lower oxygen concentrations, but instead through organismal oxygen demand exceeding supply. This reappraisal of how organismal thermal physiology and oxygen demands together shape aerobic performance in aquatic ectotherms and the new insight of how these components change with temperature have broad implications for predicting the responses of aquatic communities to

  20. Growth of MoO{sub 3} nanostructured thin films as a function of O{sub 2}-partial pressure

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rabindar Kumar, E-mail: rkrksharma6@gmail.com; Kumar, Prabhat; Reddy, G. B. [Thin film Laboratory, Department of Physics, Indian Institute of Technology Delhi -110016 (India)

    2015-06-24

    In this report, we synthesized molybdenum trioxide (α-MoO{sub 3}) nanostructured thin films (NST{sub s}) with nanoflakes (NF{sub s}) on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of oxygen partial pressure (PO{sub 2}). The effect of oxygen partial pressure on structural, morphological, and vibrational properties have been investigated systematically. The structural analysis divulged that all films deposited at different PO{sub 2} have pure orthorhombic phase, no impurity phase is detected under the limit of resolution. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment of MoO{sub 3} NST{sub s} can be monitored by PO{sub 2} and the sample having best features is obtained at 7.5×10{sup −2} Torr. In addition, the more insight information is accomplished by TEM/HRTEM on the best featured sample, which confirmed the single crystalline nature of nanoflakes. The vibrational study of all samples are performed by FTIR, and strongly supports the XRD observations. All the results are in consonance with each other.

  1. Biomass hydrolysis inhibition at high hydrogen partial pressure in solid-state anaerobic digestion.

    Science.gov (United States)

    Cazier, E A; Trably, E; Steyer, J P; Escudie, R

    2015-08-01

    In solid-state anaerobic digestion, so-called ss-AD, biogas production is inhibited at high total solids contents. Such inhibition is likely caused by a slow diffusion of dissolved reaction intermediates that locally accumulate. In this study, we investigated the effect of H2 and CO2 partial pressure on ss-AD. Partial pressure of H2 and/or CO2 was artificially fixed, from 0 to 1 557mbars for H2 and from 0 to 427mbars for CO2. High partial pressure of H2 showed a significant effect on methanogenesis, while CO2 had no impact. At high [Formula: see text] , the overall substrate degradation decreased with no accumulation of metabolites from acidogenic bacteria, indicating that the hydrolytic activity was specifically impacted. Interestingly, such inhibition did not occur when CO2 was added with H2. This result suggests that CO2 gas transfer is probably a key factor in ss-AD from biomass.

  2. Plateau Waves of Intracranial Pressure and Multimodal Brain Monitoring.

    Science.gov (United States)

    Dias, Celeste; Maia, Isabel; Cerejo, Antonio; Smielewski, Peter; Paiva, José-Artur; Czosnyka, Marek

    2016-01-01

    The aim of this study was to describe multimodal brain monitoring characteristics during plateau waves of intracranial pressure (ICP) in patients with head injury, using ICM+ software for continuous recording. Plateau waves consist of an abrupt elevation of ICP above 40 mmHg for 5-20 min. This is a prospective observational study of patients with head injury who were admitted to a neurocritical care unit and who developed plateau waves. We analyzed 59 plateau waves that occurred in 8 of 18 patients (44 %). At the top of plateau waves arterial blood pressure remained almost constant, but cerebral perfusion pressure, cerebral blood flow, brain tissue oxygenation, and cerebral oximetry decreased. After plateau waves, patients with a previously better autoregulation status developed hyperemia, demonstrated by an increase in cerebral blood flow and brain oxygenation. Pressure and oxygen cerebrovascular reactivity indexes (pressure reactivity index and ORxshort) increased significantly during the plateau wave as a sign of disruption of autoregulation. Bedside multimodal brain monitoring is important to characterize increases in ICP and give differential diagnoses of plateau waves, as management of this phenomenon differs from that of regular ICP.

  3. Pressure mapping with textile sensors for compression therapy monitoring.

    Science.gov (United States)

    Baldoli, Ilaria; Mazzocchi, Tommaso; Paoletti, Clara; Ricotti, Leonardo; Salvo, Pietro; Dini, Valentina; Laschi, Cecilia; Francesco, Fabio Di; Menciassi, Arianna

    2016-08-01

    Compression therapy is the cornerstone of treatment in the case of venous leg ulcers. The therapy outcome is strictly dependent on the pressure distribution produced by bandages along the lower limb length. To date, pressure monitoring has been carried out using sensors that present considerable drawbacks, such as single point instead of distributed sensing, no shape conformability, bulkiness and constraints on patient's movements. In this work, matrix textile sensing technologies were explored in terms of their ability to measure the sub-bandage pressure with a suitable temporal and spatial resolution. A multilayered textile matrix based on a piezoresistive sensing principle was developed, calibrated and tested with human subjects, with the aim of assessing real-time distributed pressure sensing at the skin/bandage interface. Experimental tests were carried out on three healthy volunteers, using two different bandage types, from among those most commonly used. Such tests allowed the trends of pressure distribution to be evaluated over time, both at rest and during daily life activities. Results revealed that the proposed device enables the dynamic assessment of compression mapping, with a suitable spatial and temporal resolution (20 mm and 10 Hz, respectively). In addition, the sensor is flexible and conformable, thus well accepted by the patient. Overall, this study demonstrates the adequacy of the proposed piezoresistive textile sensor for the real-time monitoring of bandage-based therapeutic treatments.

  4. Finger and Palm Dynamic Pressure Monitoring for Basketball Shooting

    Directory of Open Access Journals (Sweden)

    Chiao-Fang Hung

    2017-01-01

    Full Text Available This study verified general inferences on the finger and palm pressure distribution of a basketball player in the moment before that player shoots a basketball through a scientific qualitative testing method. We mounted the sensor on the hands of college basketball players and monitored the dynamic pressure of each player’s hand while the player threw a basketball. The dynamic pressure distribution of the fingers and palm of a basketball player throwing a ball can be verified. According to the experimental results, college basketball players typically use the index finger to control the direction and power of force in the moment before shooting a basketball. This study successfully used a scientific qualitative test method to monitor the dynamic pressure of the fingers and palms of basketball players and verified the general inference that a typical basketball player mainly uses the index finger to control the direction and power of force in the moment before throwing a ball. In the future, this study, measuring the dynamic pressure distribution of the fingers and palm, can be applied to simulate hand manipulation in many biomedical and robotic applications.

  5. Wide vacuum pressure range monitoring by Pirani SAW sensor.

    Science.gov (United States)

    Nicolay, Pascal; Elmazria, Omar; Sarry, Frederic; Bouvot, Laurent; Kambara, Hisanori; Singh, Kanwar J; Alnot, Patrick

    2010-03-01

    A new kind of surface acoustic wave (SAW) sensor has been developed to measure sub-atmospheric pressure below 100 mtorr with accuracy better than 0.1 mtorr. It provides an efficient measuring solution in the pressure range inaccessible in past by conventional diaphragm-based SAW sensors. Indeed, because of the small bending force in lower pressure and limited sensitivity, diaphragm-based SAW sensors are only suited to monitor relatively high pressure with a precision hardly better than 0.5 torr. To reach precision level better than 1 mtorr at sub-atmospheric pressure for vacuum technology applications, a radically different SAW-based solution is necessary. Our device aims to measure sub-atmospheric pressure less than 100 mtorr with a threshold resolution better than 0.1 mtorr. The concept is similar to the one used by Pirani pressure gauges. However, it is claimed that a heated and suspended SAW device should have better sensitivity. A theoretical model based on the basic concepts of gas kinetic theory and thermodynamics is presented. The validity of the model is checked by comparison between theoretical and experimental results.

  6. Use of intracranial pressure monitoring in bacterial meningitis

    DEFF Research Database (Denmark)

    Larsen, Lykke; Rom Poulsen, Frantz; Nielsen, Troels H

    2017-01-01

    BACKGROUND: The aim of this study was to evaluate the clinical outcome of patients with severe bacterial meningitis where intracranial pressure (ICP) monitoring has been performed. METHODS: A retrospective observational study including patients admitted 1st(.) January 2005 to 31st(.) December 2014...... = 0.034). Lower mean-cerebral perfusion pressure (CPP) was found to correlate with adverse outcome (p = 0.005). Cerebrospinal fluid (CSF) was drained in fourteen patients. Increased ICP (>20 mmHg) was observed in twenty four patients. No significant correlation was found between measured ICP and head...

  7. Zero drift of intraventricular and subdural intracranial pressure monitoring systems

    OpenAIRE

    2013-01-01

    【Abstract】Objective: To assess zero drift of intra-ventricular and subdural intracranial pressure (ICP) moni-toring systems. Methods: A prospective study was conducted in pa-tients who received Codman ICP monitoring in the neuro-surgical department from January 2010 to December 2011. According to the location of sensors, the patients were ca-tegorized into two groups: intraventricular group and sub-dural group. Zero drift between the two groups and its as-sociation with the duratio...

  8. Intracranial pressure monitoring and outcomes after traumatic brain injury

    Science.gov (United States)

    Lane, Peter L.; Skoretz, Terry G.; Doig, Gordon; Girotti, Murray J.

    2000-01-01

    Objective Uncontrolled intracranial hypertension after traumatic brain injury (TBI) contributes significantly to the death rate and to poor functional outcome. There is no evidence that intracranial pressure (ICP) monitoring alters the outcome of TBI. The objective of this study was to test the hypothesis that insertion of ICP monitors in patients who have TBI is not associated with a decrease in the death rate. Design Study of case records. Methods The data files from the Ontario Trauma Registry from 1989 to 1995 were examined. Included were all cases with an Injury Severity Score (ISS) greater than 12 from the 14 trauma centres in Ontario. Cases identifying a Maximum Abbreviated Injury Scale score in the head region (MAIS head) greater than 3 were selected for further analysis. Logistic regression analyses were conducted to investigate the relationship between ICP and death. Results Of 9001 registered cases of TBI, an MAIS head greater than 3 was recorded in 5507. Of these patients, 541 (66.8% male, mean age 34.1 years) had an ICP monitor inserted. Their average ISS was 33.4 and 71.7% survived. There was wide variation among the institutions in the rate of insertion of ICP monitors in these patients (ranging from 0.4% to over 20%). Univariate logistic regression indicated that increased MAIS head, ISS, penetrating trauma and the insertion of an ICP monitor were each associated with an increased death rate. However, multivariate analyses controlling for MAIS head, ISS and injury mechanism indicated that ICP monitoring was associated with significantly improved survival (p < 0.015). Conclusions ICP monitor insertion rates vary widely in Ontario’s trauma hospitals. The insertion of an ICP monitor is associated with a statistically significant decrease in death rate among patients with severe TBI. This finding strongly supports the need for a prospective randomized trial of management protocols, including ICP monitoring, in patients with severe TBI. PMID:11129833

  9. Design of a split Hopkinson pressure bar with partial lateral confinement

    Science.gov (United States)

    Barr, Andrew D.; Clarke, Sam D.; Rigby, Sam E.; Tyas, Andrew; Warren, James A.

    2016-12-01

    This paper presents the design of a modified split Hopkinson pressure bar (SHPB) where partial lateral confinement of the specimen is provided by the inertia of a fluid annulus contained in a long steel reservoir. In contrast to unconfined testing, or a constant cell pressure applied before axial loading, lateral restraint is permitted to develop throughout the axial loading: this enables the high-strain-rate shear behaviour of soils to be characterised under conditions which are more representative of buried explosive events. A pressure transducer located in the wall of the reservoir allows lateral stresses to be quantified, and a dispersion-correction technique is used to provide accurate measurements of axial stress and strain. Preliminary numerical modelling is utilised to inform the experimental design, and the capability of the apparatus is demonstrated with specimen results for a dry quartz sand.

  10. [Outpatient blood pressure monitoring is not always necessary].

    Science.gov (United States)

    Divisón Garrote, J A

    It is clear that clinical measurements of blood pressure can lead to errors in the diagnostic process and follow-up of patients with hypertension. Scientific societies recommend other measurement methods, such as home measurements and outpatient monitoring. Outpatient monitoring might be the golden standard but, nowadays has an important limitation-its availability. Home measurements solve 80-90% of the doubts of the diagnostic process and follow-up of patients with hypertension, and its higher availability and acceptance by the patient are clear. Home measurements should be used in the diagnostic process of arterial hypertension as a screening test for white coat hypertension and masked hypertension. They should be used as a screening test for resistant hypertension in the follow-up of patients with high blood pressure. Besides, in the follow-up of patients with hypertension home measurements have shown that they can contribute to treatment adherence, reduce clinical inertia and make data teletransmission possible, aspects that have proven to help improve the degree of control of hypertensive patients. Therefore, home measurements would be the treatment of choice for the diagnosis and follow-up of most patients with hypertension. We should consider home measurements and outpatient monitoring as complementary methods for the diagnosis and follow-up of patients with high blood pressure. Copyright © 2016. Publicado por Elsevier España, S.L.U.

  11. Experimental and numerical analysis of pressure pulses characteristics in a Francis turbine with partial load

    Energy Technology Data Exchange (ETDEWEB)

    Yexiang, X; Zhengwei, W; Zongguo, Y; Jin, Z, E-mail: xiaoyex@mail.tsinghua.edu.c [State Key Laboratory of Hydroscience and Engineering and Department of Thermal Engineering, Tsinghua University Beijing, 100084 (China)

    2010-08-15

    This study experimentally and numerically investigates the pressure pulses characteristics and unsteady flow behavior in a Francis turbine with partial load. Unsteady wall pressure measurements with partial load condition are performs to investigate thoroughly pressure fields in the spiral case, runner head cover and straight draft tube dynamically. The unsteady Reynolds- averaged Navier-Stokes equations with the k-{omega}based SST turbulence model were used to model the unsteady flow within the entire flow passage of the Francis turbine. The dominate frequency of the predicted pressure pulses at runner inlet agree with the experimental results in the head cover. The influence of the blade passing frequency causes the simulated peak-to-peak amplitudes in the runner inlet to be larger than in the head cover. The measured and predicted pressure pulses at different positions along the runner are comparable. The predicted pressure fluctuations in the draft tube agree well with the experimental results. However the peak-to-peak amplitudes in the spiral case are not as well predicted so the calculation domain and the inlet boundary conditions need to be improved. At the most unstable operating condition, the pulse in the flow passage are due to the rotor-stator interference (RSI) between the runner and the guide vanes, the blade channel vortex in the runner blade passage and the vortex rope in the draft tube. The unsteady flow patterns in the turbine, including the blade channel vortex in the runner and the helical vortex rope in the draft tube, are classified numerically.

  12. APPLICATION OF THE ROOF DISTURBANCETO MONITORING AND PREDICTINGTHE GROUND PRESSURE

    Institute of Scientific and Technical Information of China (English)

    付国彬; 钱鸣高

    1992-01-01

    Based on study of the influence of main roof fracture on ground pressure,this paper considered the immediate roof as a semi-infinite long beam on a Winkler elastic foundation. In the model the coal seam is the foundation and the pressure caused by rnian roof deflection is the load.Having solved the model and analyzed relevant factors,the authors indicate that the disturbance caused by the breakage of the mian roof can be observed in both gates of iongwaii face and explain why it can be. The paper points out that the applicability of the method to obtain the disturbance information by measuring the loads on supports is wider than that by measuring the roof convergence rate. The results are useful for monitoring and predicting ground pressure.

  13. Review on pressure sensors for structural health monitoring

    Science.gov (United States)

    Sikarwar, Samiksha; Satyendra; Singh, Shakti; Yadav, B. C.

    2017-08-01

    This paper reports the state of art in a variety of pressure and the detailed study of various matrix based pressure sensors. The performances of the bridges, buildings, etc. are threatened by earthquakes, material degradations, and other environmental effects. Structural health monitoring (SHM) is crucial to protect the people and also for assets planning. This study is a contribution in developing the knowledge about self-sensing smart materials and structures for the construction industry. It deals with the study of self-sensing as well as mechanical and electrical properties of different matrices based on pressure sensors. The relationships among the compression, tensile strain, and crack length with electrical resistance change are also reviewed.

  14. On preventive blood pressure self-monitoring at home

    DEFF Research Database (Denmark)

    Verdezoto, Nervo; Grönvall, Erik

    2015-01-01

    -called Quantified Self). In this article, we explore socio-technical complexities that may occur when introducing preventive health-measurement technologies into older adults’ daily routines and everyday lives. In particular, the original study investigated blood pressure (BP) measurement in non-clinical settings......, to understand existing challenges, and uncover opportunities for self-monitoring technologies to support preventive healthcare activities among older adults. From our study, several important aspects emerged to consider when designing preventive self-monitoring technology, such as the complexity of guidelines...... to develop better tools to support people’s preventive self-monitoring needs, compared to existing solutions. Supporting the active and informed individual can help improve people’s self-care, awareness, and implementation of preventive care. Based on our study, we also reflect on the findings to illustrate...

  15. Pediatric ambulatory blood pressure monitoring: indications and interpretations.

    Science.gov (United States)

    Flynn, Joseph T; Urbina, Elaine M

    2012-06-01

    The prevalence of hypertension in children and adolescents is increasing, especially in obese and ethnic children. The adverse long-term effects of hypertension beginning in youth are known; therefore, it is important to identify young patients who need intervention. Unfortunately, measuring blood pressure (BP) is difficult due to the variety of techniques available and innate biologic variation in BP levels. Ambulatory BP monitoring may overcome some of the challenges clinicians face when attempting to categorize a young patient's BP levels. In this article, the authors review the use of ambulatory BP monitoring in pediatrics, discuss interpretation of ambulatory BP monitoring, and discuss gaps in knowledge in usage of this technique in the management of pediatric hypertension.

  16. Using Advanced Tensiometers to Monitor Temporal Variations in Pore Pressure

    Science.gov (United States)

    Nichols, R. L.; Young, M. H.; Dixon, K. L.; Rossabi, J.; Hyde, W. K.; Holmes-Burns, H.

    2002-12-01

    The Savannah River Site has installed a comprehensive vadose zone monitoring system (VZMS) at it's low level radioactive waste disposal facility to collect the necessary information to calculate contaminant flux. The VZMS includes water content reflectometers, suction lysimeters, advanced tensiometers (ATs), water flux meters, access ports for neutron probes, and a tipping bucket rain gauge. Forty one ATs were installed from 1999 to 2001 at depths ranging from 2 to 60 feet and have been operated continuously. The installation depths were based on a hydrostatigraphic model developed from core logs, cone penetrometer logs, moisture content profiles, water retention curves model that were obtained during the phased installation of the VZMS. An AT consists of a porous cup installed at a prescribed depth with casing back to the surface and a pressure transducer that is lowered into the casing and connects with the porous cup. The pressure transducer transmits it's signal to a datalogger where the data is stored for future retrieval using a cellular phone communications package. Results from the 2 year operating period show that the AT calibrations are stable and t ATs are capable of extended monitoring of pore pressures in the 0 to 300 cm H2 O range. The ATs had sufficient resolution to detect the naturally occurring fluctuations in pore pressure (1 to 100 cm H2 O over 1 to 72 hours) that resulted from infiltration events at the site. The stable performance of the ATs combined with their ability to detect naturally occurring fluctuations in pore pressure make the ATs a useful tool in measuring temporal pore pressure variations for use in calibrating numerical models of fluid flow in variably saturated porous media.

  17. Zero drift of intraventricular and subdural intracranial pressure monitoring systems

    Institute of Scientific and Technical Information of China (English)

    CHEN Li; DU Hang-gen; YIN Li-chun; HE Min; ZHANG Guo-jun; TIAN Yong; WANG Cheng

    2013-01-01

    Objective:To assess zero drift of intraventricular and subdural intracranial pressure (ICP) monitoring systems.Methods:A prospective study was conducted in patients who received Codman ICP monitoring in the neurosurgical department from January 2010 to December 2011.According to the location of sensors,the patients were categorized into two groups:intraventricular group and subdural group.Zero drift between the two groups and its association with the duration of ICP monitor were analyzed.Results:Totally,22 patients undergoing intraventricular ICP monitoring and 27 receiving subdural ICP monitoring were enrolled.There was no significant difference in duration of ICP monitoring,zero drift value and its absolute value between intraventricular and subdural groups (5.38 d±2.58 d vs 4.58 d±2.24d,0.77 mmHg±2.18 mm Hg vs 1.03 mmHg±2.06mmHg,1.68 mmHg±155 mmHg vs 1.70mmHg±153 mmHg,respectively; all P>0.05).Absolute value of zero drift in both groups significantly rose with the increased duration of ICP monitoring (P<0.05) while zero drift value did not.Moreover,daily absolute value in the intraventricular group was significantly smaller than that in the subdural group (0.27 mm Hg±0.32 mm Hg vs 0.29 mm Hg±0.18 mm Hg,P<0.05).Conclusion:This study demonstrates that absolute value of zero drift significantly correlates with duration of both intraventricular and subdural ICP monitoring.Due to the smaller daily absolute value,ICP values recorded from intraventricular system may be more reliable than those from subdural system.

  18. Using ambulatory blood pressure monitoring to assess blood pressure of firefighters with parental history of hypertension.

    Science.gov (United States)

    de Mattos, Carlos Eduardo; de Mattos, Marco Antonio; Toledo, Daniele Gusmão; de Siqueira Filho, Aristarco Gonçalves

    2006-12-01

    To evaluate the influence of family history of systemic arterial hypertension (FSAH) on the effect of stress from work in Uniformed Firefighters (BMCs) through Ambulatory Blood Pressure Monitoring (ABPM). A prospective case-control study. Sixty-six healthy BMC underwent ABPM during 12 hours of work at the Communication Center (CC). Thirty-four had hypertensive parents (group 1) and thirty-two had normotensive parents (group 2). Group I differed from group 2 in that it showed higher mean systolic (134.1 +/- 9.9 mmHg X 120.8 +/- 9.9 mmHg p pressure, in addition to greater systolic (31.4 +/- 25.6 % X 9.4 +/- 9.4 % p = 0.0001) and diastolic (28.3 +/- 26.6 % X 6.1 +/- 8.9 % p = 0.0001) loads. The prevalence of systemic arterial hypertension (SAH) in group 1 at the workplace was 32.3%. Monitored away from the job, these subjects showed normal blood pressure (functionally hypertensive). Group 2 revealed normal blood pressure (BP) at work. Higher blood pressure in BMC with hypertensive parents is explained independently by the SAH. Subjects who developed SAH during their work at the CC may be considered functionally hypertensive, whereas those with normotensive parents and who underwent psychological stress are free of blood pressure changes.

  19. Blood pressure monitor with a position sensor for wrist placement to eliminate hydrostatic pressure effect on blood pressure measurement.

    Science.gov (United States)

    Sato, Hironori; Koshimizu, Hiroshi; Yamashita, Shingo; Ogura, Toshihiko

    2013-01-01

    Accurate measurement of blood pressure at wrist requires the heart and wrist to be kept at the same level to avoid the effects of hydrostatic pressure. Although a blood pressure monitor with a position sensor that guides appropriate forearm angle without use of a chair and desk has already been proposed, a similar functioning device for measuring upper arm blood pressure with a chair and desk is needed. In this study, a calculation model was first used to explore design of such a system. The findings were then implemented into design of a new blood pressure monitor. Results of various methods were compared. The calculation model of the wrist level from arthrosis angles and interarticulars lengths was developed and considered using published anthropometric dimensions. It is compared with 33 volunteer persons' experimental results. The calculated difference of level was -4.1 to 7.9 (cm) with a fixed chair and desk. The experimental result was -3.0 to 5.5 (cm) at left wrist and -2.1 to 6.3(cm) at right wrist. The absolute difference level equals ±4.8 (mmHg) of blood pressure readings according to the calculated result. This meets the AAMI requirements for a blood pressure monitor. In the conclusion, the calculation model is able to effectively evaluate the difference between the heart and wrist level. Improving the method for maintaining wrist to heart level will improve wrist blood pressure measurement accuracy when also sitting in the chair at a desk. The leading angle of user's forearm using a position sensor is shown to work for this purpose.

  20. Personalizing Intraocular Pressure: Target Intraocular Pressure in the Setting of 24-Hour Intraocular Pressure Monitoring.

    Science.gov (United States)

    Sit, Arthur J; Pruet, Christopher M

    2016-01-01

    Determining target intraocular pressure (IOP) in glaucoma patients is multifaceted, requiring attention to many different factors such as glaucoma type, severity of disease, age, race, family history, corneal thickness and hysteresis, and initial IOP. Even with all these variables accounted for, there are still patients who have progression of the disease despite achieving target IOP. Intraocular pressure variability has been identified as a potential independent risk factor for glaucoma progression but is currently difficult to quantify in individual patients. New technologies enabling measurement of both diurnal and nocturnal IOP may necessitate modifying our concept of target pressure.

  1. Sensor for measuring hydrogen partial pressure in parabolic trough power plant expansion tanks

    Science.gov (United States)

    Glatzmaier, Greg C.; Cooney, Daniel A.

    2017-06-01

    The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

  2. Sensor for Measuring Hydrogen Partial Pressure in Parabolic Trough Power Plant Expansion Tanks

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cooney, Daniel A.

    2017-06-27

    The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

  3. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  4. Toxicity of elevated partial pressures of carbon dioxide to invasive New Zealand mudsnails

    Science.gov (United States)

    Nielson, R. Jordan; Moffitt, Christine M.; Watten, Barnaby J.

    2012-01-01

    The authors tested the efficacy of elevated partial pressures of CO2 to kill invasive New Zealand mudsnails. The New Zealand mudsnails were exposed to 100 kPa at three water temperatures, and the survival was modeled versus dose as cumulative °C-h. We estimated an LD50 of 59.4°C-h for adult and juvenile New Zealand mudsnails. The results suggest that CO2 may be an effective and inexpensive lethal tool to treat substrates, tanks, or materials infested with New Zealand mudsnails.

  5. Intracranial pressure and cerebral perfusion pressure monitoring in non-TBI patients: special considerations.

    Science.gov (United States)

    Helbok, Raimund; Olson, DaiWai M; Le Roux, Peter D; Vespa, Paul

    2014-12-01

    The effect of intracranial pressure (ICP) and the role of ICP monitoring are best studied in traumatic brain injury (TBI). However, a variety of acute neurologic illnesses e.g., subarachnoid hemorrhage, intracerebral hemorrhage, ischemic stroke, meningitis/encephalitis, and select metabolic disorders, e.g., liver failure and malignant, brain tumors can affect ICP. The purpose of this paper is to review the literature about ICP monitoring in conditions other than TBI and to provide recommendations how the technique may be used in patient management. A PubMed search between 1980 and September 2013 identified 989 articles; 225 of which were reviewed in detail. The technique used to monitor ICP in non-TBI conditions is similar to that used in TBI; however, indications for ICP monitoring often are intertwined with the presence of obstructive hydrocephalus and hence the use of ventricular catheters is more frequent. Increased ICP can adversely affect outcome, particularly when it fails to respond to treatment. However, patients with elevated ICP can still have favorable outcomes. Although the influence of ICP-based care on outcome in non-TBI conditions appears less robust than in TBI, monitoring ICP and cerebral perfusion pressure can play a role in guiding therapy in select patients.

  6. Magnetic sensor for arterial distension and blood pressure monitoring.

    Science.gov (United States)

    Ruhhammer, Johannes; Herbstritt, Tamara; Ruh, Dominic; Foerster, Katharina; Heilmann, Claudia; Beyersdorf, Friedhelm; Goldschmidtboeing, Frank; Seifert, Andreas; Woias, Peter

    2014-12-01

    A novel sensor for measuring arterial distension, pulse and pressure waveform is developed and evaluated. The system consists of a magnetic sensor which is applied and fixed to arterial vessels without any blood vessel constriction, hence avoiding stenosis. The measurement principle could be validated by in vitro experiments on silicone tubes, and by in vivo experiments in an animal model, thereby indicating the non-linear viscoelastic characteristics of real blood vessels. The sensor is capable to provide absolute measurements of the dynamically varying arterial diameter. By calibrating the sensor, a long-term monitoring system for continuously measuring blood pressure and other cardiovascular parameters could be developed based on the method described. This will improve diagnostics for high risk patients and enable a better, specific treatment.

  7. Ambulatory Blood Pressure Monitoring – Clinical Practice Recommendations

    Directory of Open Access Journals (Sweden)

    Katalin Mako

    2016-09-01

    Full Text Available Ambulatory blood pressure monitoring (ABPM became a subject of considerable scientific interest. Due to the increasing use of the ABPM in everyday clinical practice it is important that all the users have a correct knowledge on the clinical indications, the methodology of using the device including some technical issues and the interpretation of results. In the last years several guidelines and position papers have been published with recommendations for the monitoring process, reference values, for clinical practice and research. This paper represents a summary of the most important aspects related to the use of ABPM in daily practice, being a synthesis of recommendations from the recent published guidelines and position papers. This reference article presents the practical and technical issues of ABPM, the use of this method in special situations, the clinical interpretation of measured values including the presentation of different ABPM patterns, derived parameters, the prognostic significance and the limitations of this method.

  8. Intracranial pressure monitoring for special patterns of frontal lobe contusions

    Institute of Scientific and Technical Information of China (English)

    DONG Ji-rong; CAI Xue-jian; WANG Biao; WANG Yu-hai; SHI Zhong-hua; LIU Bing; CAI Sang; XU Qin-yi

    2010-01-01

    Objective:To study the effect and indications of intracranial pressure(ICP)monitoring for frontal lobe contusion patients.Methods:During January 2005-December 2008,34 cases of frontal lobe contusion received ICP monitoring in our department(monitoring group).Different treatment protocols were adopted according to the results of ICP.Meanwhile 46 cases of same type of head-injured patients who did not undergo ICP monitoring served as control group.Results:We found that ICP elevated dramatically within 24 hours after head injury if the contusions were located in frontal longitudinal dehiscence,bilateral undersurface of frontal lobe or dispersed in bilateral lobe.After half a year follow-up and on the basis of Glasgow Coma Scale assessment,the monitoring group showed better outcome than the control group with good recovery in 24 cases(70.6%),moderate disability in 7 cases(20.6%),severe disability in 2(5.88%)and death in 1(2.94%).The outcome of control group displayed good condition in 25 cases(54.3%),moderate disabilities in 8(17.4%),severe disability in 7(15.2%),and death in 6(13.0%).Conclusions:Frontal lobe contusions are vulnerable and complex head injuries,especially when the contusions are located in frontal longitudinal dehiscence,bilateral undersurface of frontal lobe or diffused in bilateral lobes.These patients should undergo ICP monitoring regardless of their consciousness status.If ICP elevates over 25 mm Hg,the craniotomy is mandatory and will markedly reduce the mortality and disability of these patients.

  9. Long-Term Stroke Risk Due to Partial White-Coat or Masked Hypertension Based on Home and Ambulatory Blood Pressure Measurements: The Ohasama Study.

    Science.gov (United States)

    Satoh, Michihiro; Asayama, Kei; Kikuya, Masahiro; Inoue, Ryusuke; Metoki, Hirohito; Hosaka, Miki; Tsubota-Utsugi, Megumi; Obara, Taku; Ishiguro, Aya; Murakami, Keiko; Matsuda, Ayako; Yasui, Daisaku; Murakami, Takahisa; Mano, Nariyasu; Imai, Yutaka; Ohkubo, Takayoshi

    2016-01-01

    The prognostic significance of white-coat hypertension (WCHT) is controversial, and different findings on self-measured home measurements and 24-h ambulatory monitoring make identifying WCHT difficult. We examined whether individuals with partially or completely defined WCHT, as well as masked hypertension, as determined by different out-of-office blood pressure measurements, have a distinct long-term stroke risk. We followed 1464 participants (31.8% men; mean age, 60.6±10.8 years) in the general population of Ohasama, Japan, for a median of 17.1 years. A first stroke occurred in 212 subjects. Using sustained normal blood pressure (events/n=61/776) as a reference, adjusted hazard ratios for stroke (95% confidence intervals; events/n) were 1.38 (0.82-2.32; 19/137) for complete WCHT (isolated office hypertension), 2.16 (1.36-3.43; 29/117) for partial WCHT (either home or ambulatory normotension with office hypertension), 2.05 (1.24-3.41; 23/100) for complete masked hypertension (both home and ambulatory hypertension with office normotension), 2.08 (1.37-3.16; 38/180) for partial masked hypertension (either home or ambulatory hypertension with office normotension), and 2.46 (1.61-3.77; 42/154) for sustained hypertension. When partial WCHT and partial masked hypertension groups were further divided into participants only with home hypertension and those only with ambulatory hypertension, all subgroups had a significantly higher stroke risk (adjusted hazard ratio ≥1.84, P≤0.04). In conclusion, impacts of partial WCHT as well as partial masked hypertension for long-term stroke risk were comparable to those of complete masked hypertension or sustained hypertension. We need both home and 24-h ambulatory blood pressure measurements to evaluate stroke risk accurately.

  10. DEVELOPMENT OF PRESSURIZED CIRCULATIONG FLUIDIZED BED PARTIAL GASIFICATION MODULE(PGM)

    Energy Technology Data Exchange (ETDEWEB)

    Archie Robertson

    2003-04-17

    Foster Wheeler Power Group, Inc. is working under US Department of Energy contract No. DE-FC26-00NT40972 to develop a partial gasification module (PGM) that represents a critical element of several potential coal-fired Vision 21 plants. When utilized for electrical power generation, these plants will operate with efficiencies greater than 60% and produce near zero emissions of traditional stack gas pollutants. The new process partially gasifies coal at elevated pressure producing a coal-derived syngas and a char residue. The syngas can be used to fuel the most advanced power producing equipment such as solid oxide fuel cells or gas turbines, or processed to produce clean liquid fuels or chemicals for industrial users. The char residue is not wasted; it can also be used to generate electricity by fueling boilers that drive the most advanced ultra-supercritical pressure steam turbines. The amount of syngas and char produced by the PGM can be tailored to fit the production objectives of the overall plant, i.e., power generation, clean liquid fuel production, chemicals production, etc. Hence, PGM is a robust building block that offers all the advantages of coal gasification but in a more user-friendly form; it is also fuel flexible in that it can use alternative fuels such as biomass, sewerage sludge, etc. This report describes the work performed during the January 1--March 31, 2003 time period.

  11. Effect of partial pressure of reactive gas on chromium nitride and chromium oxide deposited by arc ion plating

    Institute of Scientific and Technical Information of China (English)

    LI Ming-sheng; FENG Chang-jie; WANG Fu-hui

    2006-01-01

    The effects of reactive gas partial pressure on droplet formation,deposition rate and change of preferred orientation of CrN and Cr2O3 coatings were studied. For CrN coatings,as nitrogen partial pressure increases,the number and size of droplets increases,the deposition rate initially increases obviously and then slowly,and the preferred orientation of CrN changes from high-index plane to low-index one. For Cr2O3 coatings,with the increase of oxygen partial pressure,the number and size of droplets decreases,the deposition rate decreases and the (300) becomes the preferred orientation. These differences are ascribed to the formation of CrN (with a lower melting point) and Cr2O3 (with a higher melting point) on the surface of Cr target during the deposition of CrN and Cr2O3. Complete coatings CrN or Cr2O3 film can be formed when reactive gas partial pressure gets up to 0.1 Pa. The optimized N2 partial pressure for CrN deposition is about 0.1-0.2 Pa in order to suppress the formation of droplets and the suitable O2 partial pressure for Cr2O3 deposition is approximately 0.1 Pa for the attempt to prevent the peel of the coating.

  12. SrRuO3 thin films grown on MgO substrates at different oxygen partial pressures

    KAUST Repository

    Zou, Bin

    2013-01-08

    A comprehensive study of SrRuO3 thin films growth on (001) MgO substrates by pulsed laser deposition in a wide oxygen pressure range from 10 to 300 mTorr was carried out. The experimental results showed a correlation between the lattice constants, resistivity, and oxygen partial pressures used. Ru deficiency detected only in films deposited at lower oxygen pressures (<50 mTorr), resulted in an elongation of the in-plane and out-of-plane lattice constants and an increase in the film resistivity. When deposited with oxygen partial pressure of 50 mTorr, SrRuO3 films had lattice parameters matching those of bulk SrRuO3 material and exhibited room temperature resistivity of 320 μΩ·cm. The resistivity of SrRuO 3/MgO films decreased with increasing oxygen partial pressure. Copyright © 2013 Materials Research Society.

  13. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  14. Transcutaneous carbon-dioxide partial pressure trends during six-minute walk test in patients with very severe COPD.

    Science.gov (United States)

    Andrianopoulos, Vasileios; Vanfleteren, Lowie E G W; Jarosch, Inga; Gloeckl, Rainer; Schneeberger, Tessa; Wouters, Emiel F M; Spruit, Martijn A; Kenn, Klaus

    2016-11-01

    Transcutaneous carbon-dioxide partial-pressure (TCPCO2) can be reliably measured and may be of clinical relevance in COPD. Changes in TCPCO2 and exercise-induced hypercapnia (EIH) during six-minute walk test (6MWT) need further investigation. We aimed (1) to define patterns of TCPCO2 trends during 6MWT and (2) to study determinants of CO2-retention and EIH. Sixty-two COPD patients (age: 63±8years, FEV1: 33±10%pred.) were recruited and TCPCO2 was recorded by SenTec digital-monitoring-system during 6MWT. Half of patients (50%) exhibited CO2-retention (TCPCO2[Δ]>4mmHg); 26% preserved and 24% reduced TCPCO2. Nineteen (31%) patients presented EIH (TCPCO2>45mmHg). EIH was associated to higher baseline-PCCO2, worse FEV1, lower inspiratory-pressures, underweight/normal BMI, and pre-walk dyspnea. Stronger determinants of CO2-retention were FEV1 and pre-walk dyspnea, whereas baseline-PCCO2 and pre-walk dyspnea better predict EIH. PCO2 response to 6MWT is highly heterogeneous; however, very low FEV1 and elevated baseline-PCCO2 together with pre-walk dyspnea increase the risk for CO2-retention and EIH. Overweight-BMI seems to carry a protective effect against EIH in very severe COPD. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Local Leak Detection and Health Monitoring of Pressurized Tanks

    Science.gov (United States)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  16. Additive hazards regression and partial likelihood estimation for ecological monitoring data across space.

    Science.gov (United States)

    Lin, Feng-Chang; Zhu, Jun

    2012-01-01

    We develop continuous-time models for the analysis of environmental or ecological monitoring data such that subjects are observed at multiple monitoring time points across space. Of particular interest are additive hazards regression models where the baseline hazard function can take on flexible forms. We consider time-varying covariates and take into account spatial dependence via autoregression in space and time. We develop statistical inference for the regression coefficients via partial likelihood. Asymptotic properties, including consistency and asymptotic normality, are established for parameter estimates under suitable regularity conditions. Feasible algorithms utilizing existing statistical software packages are developed for computation. We also consider a simpler additive hazards model with homogeneous baseline hazard and develop hypothesis testing for homogeneity. A simulation study demonstrates that the statistical inference using partial likelihood has sound finite-sample properties and offers a viable alternative to maximum likelihood estimation. For illustration, we analyze data from an ecological study that monitors bark beetle colonization of red pines in a plantation of Wisconsin.

  17. Hydro-isomerization of n-hexane on bi-functional catalyst: Effect of total and hydrogen partial pressures

    Science.gov (United States)

    Thoa, Dao Thi Kim; Loc, Luu Cam

    2017-09-01

    The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.

  18. Accuracy of the Dinamap 1846 XT automated blood pressure monitor.

    Science.gov (United States)

    Beaubien, E R; Card, C M; Card, S E; Biem, H J; Wilson, T W

    2002-09-01

    Accurate blood pressure (BP) measurement is important for the detection and treatment of hypertension. Despite widespread use of automated devices, there is limited published evidence for their reliability and accuracy. To determine the reliability and accuracy of the Dinamap 1846XT (Critikon Corporation, Tampa, FL, USA), a commonly used non-invasive oscillometric BP monitor The Dinamap was evaluated against the mercury manometer in 70 randomly selected adult hospitalised medical patients. Each individual underwent three sets of standardised BP measurement by automated method and three sets by mercury manometer by two independent observers. Reliability of BP measurement was assessed by repeated measures analysis. Dinamap accuracy was evaluated according to the American Association of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) guidelines. Most patients were either normotensive or had stage I hypertension. The Dinamap tended to overestimate lower diastolic BP, and displayed poor reliability (P mercury manometer and 84% of systolic and 80% of diastolic readings were within 10 mm hg (bhs grade c). systolic and diastolic accuracy were worse with pressures >160/90 mm Hg (grade D) although these measures were based on a smaller sample of subjects. In conclusion the Dinamap yields inaccurate estimates of both systolic and diastolic BP even under standardised, and thus optimal conditions. This inaccuracy is exaggerated at higher BP (>160/90 mm Hg), although the number of measurements at higher pressures was small. We recommend that this device not be used when accurate BP measurement is needed for therapeutic decision-making.

  19. Biotelemetric Wireless Intracranial Pressure Monitoring: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Mohammad H. Behfar

    2015-01-01

    Full Text Available Assessment of intracranial pressure (ICP is of great importance in management of traumatic brain injuries (TBIs. The existing clinically established ICP measurement methods require catheter insertion in the cranial cavity. This increases the risk of infection and hemorrhage. Thus, noninvasive but accurate techniques are attractive. In this paper, we present two wireless, batteryless, and minimally invasive implantable sensors for continuous ICP monitoring. The implants comprise ultrathin (50 μm flexible spiral coils connected in parallel to a capacitive microelectromechanical systems (MEMS pressure sensor. The implantable sensors are inductively coupled to an external on-body reader antenna. The ICP variation can be detected wirelessly through measuring the reader antenna’s input impedance. This paper also proposes novel implant placement to improve the efficiency of the inductive link. In this study, the performance of the proposed telemetry system was evaluated in a hydrostatic pressure measurement setup. The impact of the human tissues on the inductive link was simulated using a 5 mm layer of pig skin. The results from the in vitro measurement proved the capability of our developed sensors to detect ICP variations ranging from 0 to 70 mmHg at 2.5 mmHg intervals.

  20. [Effect of oxygen tubing connection site on percutaneous oxygen partial pressure and percutaneous carbon dioxide partial pressure in patients with chronic obstructive pulmonary disease during noninvasive positive pressure ventilation].

    Science.gov (United States)

    Mi, S; Zhang, L M

    2017-04-12

    Objective: We evaluated the effects of administering oxygen through nasal catheters inside the mask or through the mask on percutaneous oxygen partial pressure (PcO(2))and percutaneous carbon dioxide partial pressure (PcCO(2)) during noninvasive positive pressure ventilation (NPPV) to find a better way of administering oxygen, which could increase PcO(2) by increasing the inspired oxygen concentration. Methods: Ten healthy volunteers and 9 patients with chronic obstructive pulmonary disease complicated by type Ⅱ respiratory failure were included in this study. Oxygen was administered through a nasal catheter inside the mask or through the mask (oxygen flow was 3 and 5 L/min) during NPPV. PcO(2) and PcCO(2) were measured to evaluate the effects of administering oxygen through a nasal catheter inside the mask or through the mask, indirectly reflecting the effects of administering oxygen through nasal catheter inside the mask or through the mask on inspired oxygen concentration. Results: Compared to administering oxygen through the mask during NPPV, elevated PcO(2) was measured in administering oxygen through the nasal catheter inside the mask, and the differences were statistically significant (P0.05). Conclusion: Administering oxygen through a nasal catheter inside the mask during NPPV increased PcO(2) by increasing the inspired oxygen concentration but did not increase PcCO(2). This method of administering oxygen could conserve oxygen and be suitable for family NPPV. Our results also provided theoretical basis for the development of new masks.

  1. Electrical Properties and Dilatometric Measurements of La2Mo2O9 under Low Oxygen Partial Pressure

    Institute of Scientific and Technical Information of China (English)

    夏天; 李佳艳; 骆欣; 李芹; 孟健; 曹学强

    2005-01-01

    The electrical conductivity and thermal expansion of La2Mo2O9 under low oxygen partial pressure were studied with the help of thermoelectric power and dilatometric measurements, respectively. The ionic conduction of La2Mo2O9 was predominant with the electronic transference number less than 0.05 above an oxygen partial pressure of about Po2=10-7 Pa at 700℃, and below this pressure the electronic conduction became obvious. The defect reaction and small polaron hopping among molybdenum sites were proposed to explain the electronic conduction. Accompanying the phase transition, there was a sharp increase of thermal expansion, which became more serious under low oxygen partial pressure. The substitution of lanthanum by neodymium led to the increase of electrical conductivity but the decrease of phase stability.

  2. Squeeze film problems of long partial journal bearings for non-Newtonian couple stress fluids with pressure-dependent viscosity

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jaw-Ren; Hung, Chi-Ren; Lu, Rong-Fang [Nanya Institute of Technology, Jhongli, Taiwan (China). Dept. of Mechanical Engineering; Chu, Li-Ming [I-Shou Univ., Kaohsiung, Taiwan (China). Dept. of Mechanical and Automation Engineering

    2011-08-15

    According to the experimental work of C. Barus in Am. J. Sci. 45, 87 (1893), the dependency of liquid viscosity on pressure is exponential. Therefore, we extend the study of squeeze film problems of long partial journal bearings for Stokes non-Newtonian couple stress fluids by considering the pressure-dependent viscosity in the present paper. Through a small perturbation technique, we derive a first-order closed-form solution for the film pressure, the load capacity, and the response time of partial-bearing squeeze films. It is also found that the non-Newtonian couple-stress partial bearings with pressure-dependent viscosity provide better squeeze-film characteristics than those of the bearing with constant-viscosity situation. (orig.)

  3. Squeeze Film Problems of Long Partial Journal Bearings for Non-Newtonian Couple Stress Fluids with Pressure-Dependent Viscosity

    Science.gov (United States)

    Lin, Jaw-Ren; Chu, Li-Ming; Hung, Chi-Ren; Lu, Rong-Fang

    2011-09-01

    According to the experimental work of C. Barus in Am. J. Sci. 45, 87 (1893) [1], the dependency of liquid viscosity on pressure is exponential. Therefore, we extend the study of squeeze film problems of long partial journal bearings for Stokes non-Newtonian couple stress fluids by considering the pressure-dependent viscosity in the present paper. Through a small perturbation technique, we derive a first-order closed-form solution for the film pressure, the load capacity, and the response time of partial-bearing squeeze films. It is also found that the non-Newtonian couple-stress partial bearings with pressure-dependent viscosity provide better squeeze-film characteristics than those of the bearing with constant-viscosity situation.

  4. Relating oxygen partial pressure, saturation and content: the haemoglobin–oxygen dissociation curve

    Directory of Open Access Journals (Sweden)

    Julie-Ann Collins

    2015-09-01

    The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content, saturation (SO2 and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2 is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2 as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.

  5. Integrated landslide monitoring: rainfalls, pore water pressures and surface movements

    Science.gov (United States)

    Berti, M.; Casula, G.; Elmi, C.; Fabris, M.; Ghirotti, M.; Loddo, F.; Mora, P.; Pesci, A.; Simoni, A.

    2003-04-01

    Rainfall-induced landslides involving clay-rich soils are widely represented in the Apennines. They cover up to 30% of the slopes forming the relief constituted by chaotic clayey units and are typically subject to repeated reactivations of the movement which are often triggered by a series of discrete failures located in the upper part (headscarp). Failures and movement can then propagate downslope and reactivate the whole landslide deposit which displays a typical elongated body, limited depth and a fan-shaped toe as a result of successive slow earth-flow like movements. An experimental monitoring programme was designed and is currently operating on the Rocca Pitigliana landslide whose characteristics well represent the above described type of movements. Its last parossistic movement date back to 1999 and, since then, remedial works were realized on behalf of local authorities. They basically consist of surficial and deep drainage works located on the landslide body. Experimental activities focus on the main headscarp whose morphology and sub-surface water circulation scheme were unaffected by the interventions. The monitoring approach includes measuring rainfalls and pore-pressure responses in both saturated and unsaturated soils. Surficial movements are continuously measured by means of GPS permanent stations and by wire extensometers which allow real time control of headscarp activity. Main aim of the monitoring activities is to provide experimental data, which can be used to test various existing hydrologic models and to identify triggering conditions. Since the ‘70s, many hydrologic models have been proposed to describe the pore water pressure distribution within the soil and its response to precipitation. The topic has recently drawn growing attention because of the recognized importance in landslide triggering but still experimental data are very much needed in order to obtain and validate capable predicting tools. This is mostly due to the multiple and

  6. An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-05-01

    Full Text Available Ultra-high-frequency (UHF partial discharge (PD online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new method, namely a level scanning method. The intelligent sensor can directly acquire the statistical characteristic quantities and is characterized by low cost, few data to output and transmit, Ethernet functionality, and small size for easy installation. The prototype of an intelligent sensor was made. Actual UHF PD experiments with three typical artificial defect models of power transformers were carried out in a laboratory, and the waveform recording method and intelligent sensor proposed were simultaneously used for UHF PD measurement for comparison. The results show that the proposed intelligent sensor is qualified for the UHF PD online monitoring of power transformers. Additionally, three methods to improve the performance of intelligent sensors were proposed according to the principle of the level scanning method.

  7. Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

    Science.gov (United States)

    Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz

    2015-04-01

    Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

  8. [Monitoring of intra-abdominal pressure and abdominal perfusion pressure in urgent abdominal surgery].

    Science.gov (United States)

    Raĭbuzhis, E N; Fot, E V; Gaĭdukov, K M; Kirov, M Iu

    2014-01-01

    To evaluate the changes in intra-abdominal pressure (IAP) and abdominal perfusion pressure (APP) during perioperative period in urgent abdominal surgery and to assess the relationship of these parameters with gas exchange and tissue perfusion. Twenty-four patients undergoing emergency abdominal surgery were enrolled into a prospective observational study. We recorded IAP APP, mean arterial pressure, arterial and venous blood gases after induction of anesthesia, at the end of surgery, and 6, 12, 48 and 72 h postoperatively. LAP was measured by nasogastric tube using CiMON monitor (Pulsion Medical Systems, Germany). In addition, we studied the relationship of IAP and APP with blood gases parameters. We observed perioperative increase of IAP (> 12 mm Hg) in 75% of enrolled patients, tendency to postoperative rise of IAP and transient increase of arterial lactate at 6 h after surgery. APP remained within normal values. We found positive correlation of APP with PaO2/FiO2 and ScvO2 at 72 hours after surgery. Transient perioperative increase of IAP was observed in 75% patients undergoing urgent abdominal surgery; however in parallel with intensive care the abdominal perfusion pressure remained within normal values. Abdominal perfusion is related with arterial oxygenation and central venous saturation.

  9. Noninvasive Subharmonic Pressure Estimation for Monitoring Breast Cancer Response to Neoadjuvant Therapy

    Science.gov (United States)

    2013-01-01

    AD_________________ Award Number: W81XWH-08-1-0503 TITLE: Noninvasive Subharmonic Pressure...SUBTITLE 5a. CONTRACT NUMBER Noninvasive Subharmonic Pressure Estimation for Monitoring Breast Cancer Response to Neoadjuvant Therapy 5b. GRANT...SUBTITLE Noninvasive Subharmonic Pressure Estimation for Monitoring Breast Cancer 5. FUNDING NUMBERS W81XWH-08-1-0503 6. AUTHOR(S) Flemming

  10. Blood Pressure Mobile Monitoring for Pregnant Woman Based Android System

    Science.gov (United States)

    Supriyanti, Retno; Erfayanto, Uji; Ramadani, Yogi; Murdyantoro, Eko; Widodo, Haris B.

    2016-01-01

    Currently, at least 18,000 women die every year in Indonesia due to pregnancy or childbirth. It means that every half hour a woman dies due to pregnancy or childbirth. As a result, every year 36,000 children became orphans. The high maternal mortality rate was put Indonesia on top in ASEAN. The main causes of maternal mortality are high-risk pregnancy. Mothers who have diseases like high blood pressure, pre-eclampsia, diabetes, hyperthyroidism, and already over 40 years old and infectious diseases such as rubella, hepatitis and HIV can be factors that lead to high-risk pregnancy. This paper will discuss the development of a blood pressure monitoring device that is suitable for pregnant women. It is based on convenience for pregnant women to get the equipment that is flexible with her presence. Results indicate that the equipment is in use daily support for pregnant women therefore, one of the causes of maternal mortality can be detected earlier.

  11. Mobile Personal Health System for Ambulatory Blood Pressure Monitoring

    Directory of Open Access Journals (Sweden)

    Luis J. Mena

    2013-01-01

    Full Text Available The ARVmobile v1.0 is a multiplatform mobile personal health monitor (PHM application for ambulatory blood pressure (ABP monitoring that has the potential to aid in the acquisition and analysis of detailed profile of ABP and heart rate (HR, improve the early detection and intervention of hypertension, and detect potential abnormal BP and HR levels for timely medical feedback. The PHM system consisted of ABP sensor to detect BP and HR signals and smartphone as receiver to collect the transmitted digital data and process them to provide immediate personalized information to the user. Android and Blackberry platforms were developed to detect and alert of potential abnormal values, offer friendly graphical user interface for elderly people, and provide feedback to professional healthcare providers via e-mail. ABP data were obtained from twenty-one healthy individuals (>51 years to test the utility of the PHM application. The ARVmobile v1.0 was able to reliably receive and process the ABP readings from the volunteers. The preliminary results demonstrate that the ARVmobile 1.0 application could be used to perform a detailed profile of ABP and HR in an ordinary daily life environment, bedsides of estimating potential diagnostic thresholds of abnormal BP variability measured as average real variability.

  12. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.

    Science.gov (United States)

    Chen, Guo-Zhen; Chan, Ion-Seng; Leung, Leo K K; Lam, David C C

    2014-09-01

    Intraocular pressure (IOP) is a primary indicator of glaucoma, but measurements from a single visit to the clinic miss the peak IOP that may occur at night during sleep. A soft chipless contact lens sensor that allows the IOP to be monitored throughout the day and at night is developed in this study. A resonance circuit composed of a thin film capacitor coupled with a sensing coil that can sense corneal curvature deformation is designed, fabricated and embedded into a soft contact lens. The resonance frequency of the sensor is designed to vary with the lens curvature as it changes with the IOP. The frequency responses and the ability of the sensor to track IOP cycles were tested using a silicone rubber model eye. The results showed that the sensor has excellent linearity with a frequency response of ∼8 kHz/mmHg, and the sensor can accurately track fluctuating IOP. These results showed that the chipless contact lens sensor can potentially be used to monitor IOP to improve diagnosis accuracy and treatment of glaucoma.

  13. Development of pressurized coal partial combustor; Kaatsu sekitan bubun nenshoro gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T. [Center for Coal Utilization, Japan, Tokyo (Japan); Kawamura, K. [Kawasaki Heavy Industries, Ltd., Kobe (Japan); Tanaka, T. [Chubu Electric Power Co. Inc., Nagoya (Japan); Muramatsu, T. [Electric Power Development Co. Ltd., Tokyo (Japan)

    1996-09-01

    The coal partial combustor (CPC) uses a combustion technology with which coal is burned at elevated temperatures and under revolution, the constituents are captured on the furnace wall and removed as molten slag from the furnace. This is a combustion technology to reduce load of ash on subsequent devices. To generate a molten condition, it is necessary to raise the combustion temperature as high as possible (to about 1600 degC in the furnace), but this is effective for a gas turbine composite power generation system. An efficiency of higher than 45% may be expected at the power transmission terminal. As an operation on subsidy from the Agency of Natural Resources and Energy, the normal-pressure CPC technology has already been established, and a research on pressurized CPC is being progressed since fiscal 1991. The research is in progress with a schedule that elemental tests for 7 tons per day production are conducted until fiscal 1995, a 25 tons per day pilot plant will be completed by November 1997, and verification tests for long-term continuous operation will be implemented until 1998. The 7 tons per day elemental tests have identified gasification performance and slag extraction performance using five types of coal having different properties. 7 refs., 10 figs., 4 tabs.

  14. Ambulatory blood pressure monitoring in healthy children with parental hypertension.

    Science.gov (United States)

    Alpay, Harika; Ozdemir, Nihal; Wühl, Elke; Topuzoğlu, Ahmet

    2009-01-01

    The aim of this study was to compare ambulatory blood pressure monitoring (ABPM) parameters in offspring with at least one hypertensive parent (HP) to offspring with normotensive parents (NP) and to determine whether gender of parent or child might influence the association between parental hypertension and blood pressure (BP). Eighty-nine healthy children (mean age 11.1 +/- 3.9 years) with HP and 90 controls (mean age 10.5 +/- 3.1 years) with NP were recruited. Age, gender, and height did not differ between the two groups, whereas children of HP had higher weight, body mass index (BMI), and waist circumference compared with healthy controls. No difference was found in casual BP between the two groups. In contrast, during ABPM daytime and nighttime mean systolic and diastolic BP and mean arterial pressure (MAP) standard deviation scores (SDS) were significantly elevated in children with HP. The mean percentage of nocturnal BP decline (dipping) was not significantly different between the two groups. Children with hypertensive mothers had higher daytime systolic and MAP SDS than controls; no such difference was detected for children with hypertensive fathers. Daytime systolic and MAP SDS were significantly elevated in boys with HP compared with boys with NP but failed to be significant in girls. Multiple linear regression analysis showed that parental history of hypertension (B = 0.29) and BMI (B = 0.03) were independently correlated with increase of daytime MAP SDS. Early changes in ambulatory BP parameters were present in healthy children of HP. BP in HP offspring was influenced by the gender of the affected parent and the offspring.

  15. Partial melting of ultrahigh-pressure metamorphic rocks during continental collision: Evidence, time, mechanism, and effect

    Science.gov (United States)

    Chen, Yi-Xiang; Zhou, Kun; Gao, Xiao-Ying

    2017-09-01

    Partial melting of ultrahigh-pressure (UHP) metamorphic rocks during continental collision has been increasingly found in nature. More and more studies have devoted to the evidence, time, mechanism and effect of crustal anataxis at mantle to lower crust depths. This is particularly so for UHP rocks from the Dabie-Sulu orogenic belt, whereas similar studies on these issues are relatively minor for other UHP terranes. The petrological evidence, especially microstructural observations and multiphase solid inclusion analyses, have been accumulated for the partial melting of UHP metamorphic rocks in collisional orogens. The results indicate that this is a kind of low-degree crustal anataxis at convergent plate margins due to decompressional dehydration of the UHP rocks themselves. Thus it has great bearing on intracrustal differentiation and crust-mantle interaction in continental subduction channels. Zircon may grow through peritectic reactions due to the breakdown of hydrous minerals. By dating of the peritectic zircons that contain coesite or diamond inclusions, the time of crustal anatexis under UHP conditions can be directly determined. In general, the partial melting of UHP rocks mainly took place at the stage of their early exhumation, partly still in the UHP regime and partly in the subsequent high-pressure (HP) regime. The crustal anatexis still at mantle depths is common in many UHP terranes, possibly facilitating exhumation of deeply subducted continental slices toward shallower levels. Petrological and geochemical studies indicate that phengite dehydration-driven melting during exhumation is the common mechanism for the anatexis of UHP rocks, though the other hydrous minerals were also involved in this process. The resulted HP to UHP melts may occur at different spatial scales and show significant fractionation in melt-mobile incompatible trace elements such as LILE and LREE. These melts are enriched in LILE to large extent and LREE and Th to small extent

  16. Antifactor Xa levels versus activated partial thromboplastin time for monitoring unfractionated heparin.

    Science.gov (United States)

    Vandiver, Jeremy W; Vondracek, Thomas G

    2012-06-01

    Intravenous unfractionated heparin (UFH) remains an important therapeutic agent, particularly in the inpatient setting, for anticoagulation. Historically, the activated partial thromboplastin time (aPTT) has been the primary laboratory test used to monitor and adjust UFH. The aPTT test has evolved since the 1950s, and the historical goal range of 1.5-2.5 times the control aPTT, which first gained favor in the 1970s, has fallen out of favor due to a high degree of variability in aPTT readings from one laboratory to another, and even from one reagent to another. As a result, it is now recommended that the aPTT goal range be based on a corresponding heparin concentration of 0.2-0.4 unit/ml by protamine titration or 0.3-0.7 unit/ml by antifactor Xa assay. Given that several biologic factors can influence the aPTT independent of the effects of UFH, many institutions have transitioned to monitoring heparin with antifactor Xa levels, rather than the aPTT. Clinical data from the last 10-20 years have begun to show that a conversion from aPTT to antifactor Xa monitoring may offer a smoother dose-response curve, such that levels remain more stable, requiring fewer blood samples and dosage adjustments. Given the minimal increased acquisition cost of the antifactor Xa reagents, it can be argued that the antifactor Xa is a cost-effective method for monitoring UFH. In this review, we discuss the relative advantages and disadvantages of the aPTT, antifactor Xa, and protamine titration tests, and provide a clinical framework to guide practitioners who are seeking to optimize UFH monitoring within their own institutions.

  17. Influence of oxygen partial pressure on crystallization behaviour and high-temperature stability of stone wool fibres

    Energy Technology Data Exchange (ETDEWEB)

    Kaasgaard, M.; Jacobsen, P.A.L.; Yue Yuanzheng [Aalborg Univ. (Denmark). Section of Chemistry

    2005-04-01

    The influence of oxygen partial pressure on the redox state of the iron in stone wool is studied using thermogravimetry (TG). The thermal response of the stone wool is measured using differential scanning calorimetry (DSC). The high-temperature stability of stone wool depending on the oxygen partial pressure is observed using scanning electron microscopy (SEM). It is confirmed that the oxidation of Fe{sup 2+} to Fe{sup 3+} is responsible for the high-temperature stability of stone wool. Even a minor increase in oxygen partial pressure can considerably alter the crystallization behaviour and enhance the high-temperature stability of the stone wool. The origin for that is discussed. (orig.)

  18. A 2013 Survey on Pressure Monitoring in Adult Cardiopulmonary Bypass Circuits: Modes and Applications

    OpenAIRE

    Rigg, Laura; Searles, Bruce; Darling, Edward Morse

    2014-01-01

    Pressure data acquired from multiple sites of extracorporeal circuits can be an important parameter to monitor for the safe conduct of cardiopulmonary bypass (CPB). Although previous surveys demonstrate that CPB circuit pressure monitoring is widely used, there are very little data cataloging specific applications of this practice. Therefore, the purpose of this study is to survey the perfusion community to catalog 1) primary CPB circuit site pressure monitoring locations; 2) type of manomete...

  19. A 2013 Survey on Pressure Monitoring in Adult Cardiopulmonary Bypass Circuits: Modes and Applications.

    Science.gov (United States)

    Rigg, Laura; Searles, Bruce; Darling, Edward Morse

    2014-12-01

    Pressure data acquired from multiple sites of extracorporeal circuits can be an important parameter to monitor for the safe conduct of cardiopulmonary bypass (CPB). Although previous surveys demonstrate that CPB circuit pressure monitoring is widely used, there are very little data cataloging specific applications of this practice. Therefore, the purpose of this study is to survey the perfusion community to catalog 1) primary CPB circuit site pressure monitoring locations; 2) type of manometers used; 3) pressure monitoring interface and servoregulation with pump console; and 4) the rationale and documentation associated with pressure monitoring during CPB. In June 2013, a validated 27-question online survey was sent directly through an e-mail link to the chief perfusionists in the northeast United States. Completed surveys were received from 75 of 117 surveys deployed yielding a 64% response rate. Arterial line pressure monitoring during CPB is reported by 99% with six distinct circuit site locations identified. Cardioplegia system pressure was monitored by 95% of the centers. For vacuum-assisted venous drainage (VAVD) users, the venous pressure was measured by 72% of the responding centers. Arterial line pressure servoregulation of the arterial pump was indicated by 61% of respondents and 75% of centers record arterial line pressure in their perfusion record. Most centers (77%) report the use of a transducer that is integrated into the pump console providing a digital pressure display, whereas 20% combine an aneroid gauge manometer with the integrated digital transducer. This study demonstrates that the practice of arterial line pressure monitoring during CPB is nearly universal. However, the selection of the pressure monitoring site on the circuit, modes of monitoring pressure, and their applications are highly variable across the perfusion community.

  20. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study

    National Research Council Canada - National Science Library

    Romagnoli, Stefano; Ricci, Zaccaria; Quattrone, Diego; Tofani, Lorenzo; Tujjar, Omar; Villa, Gianluca; Romano, Salvatore M; De Gaudio, A Raffaele

    2014-01-01

    Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the "gold standard" for arterial pressure monitoring...

  1. Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study

    National Research Council Canada - National Science Library

    Jacq, Gwenaëlle; Gritti, Karine; Carré, Cécile; Fleury, Nadège; Lang, Annie; Courau-Courtois, Josette; Bedos, Jean-Pierre; Legriel, Stephane

    2015-01-01

    Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position...

  2. Single-walled carbon nanotube sensors for monitoring partial discharge induced dissociation of SF6.

    Science.gov (United States)

    Jung, Sehun; Choi, Jaeboong; Kim, Youngjin; Lee, Jongchul; Chang, Yongmoo; Baik, Seunghyun

    2009-12-01

    We proposed to use a miniature single-walled carbon nanotube (SWNT) sensor, fabricated by alternating current dielectrophoresis, to detect dissociated and oxidized sulfur hexafluoride (SF6) gas species generated by partial discharge (PD) activity in a concealed chamber such as gas-insulated switchgear (GIS). The SWNT sensor did not react with pure SF6 gas but sensitively responded to the dissociated and oxidized SF6 species. Also, the SWNT sensor could be regenerated by purging with fresh air since the transduction was based on the physisorption of analytes. Therefore, the SWNT sensor is a promising device for the detection of the dissociated and oxidized SF6 species and for the monitoring of the PD activity inside GIS.

  3. First Field Experience of On-line Partial Discharge Monitoring of MV Cable Systems with location

    Energy Technology Data Exchange (ETDEWEB)

    Van der Wielen, P.; Steennis, F.

    2009-06-15

    A new measuring system is presented for the on-line monitoring and location of partial discharges (PDs) in medium-voltage power cables. The system uses two inductive sensors, each at one cable end. The measuring system is called PD-OL, which stands for PD detection Online with Location. A pulse injection system is used for the time synchronization of the data intake at both cable ends and for the on-line calibration. PD data is send via internet to the KEMA Control Center for interpretation and final presentation, made visible on a secured website for the network owners. This paper discusses the basics of PD-OL and a number of measurement results.

  4. Elevated liver regeneration in response to pharmacological reduction of elevated portal venous pressure by terlipressin after partial hepatectomy.

    OpenAIRE

    Fahrner, René; Patsenker, Eleanora; De Gottardi, Andrea; Stickel, Felix; Montani, Matteo; Keogh-Stroka, Deborah M.; CANDINAS, DANIEL; Beldi, Guido

    2014-01-01

    BACKGROUND Liver regeneration is of crucial importance for patients undergoing living liver transplantations or extended liver resections and can be associated with elevated portal venous pressure, impaired hepatic regeneration, and postoperative morbidity. The aim of this study was to assess whether reduction of portal venous pressure by terlipressin improves postoperative liver regeneration in normal and steatotic livers after partial hepatectomy in a rodent model. METHODS Porta...

  5. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study

    OpenAIRE

    Mignini, Mariano Alejandro; Piacentini, Enrique; Dubin,Arnaldo

    2006-01-01

    Introduction Invasive arterial blood pressure monitoring is a common practice in intensive care units (ICUs). Accuracy of invasive blood pressure monitoring is crucial in evaluating the cardiocirculatory system and adjusting drug therapy for hemodynamic support. However, the best site for catheter insertion is controversial. Lack of definitive information in critically ill patients makes it difficult to establish guidelines for daily practice in intensive care. We hypothesize that peripheral ...

  6. Crystalline structure of ceria particles controlled by the oxygen partial pressure and STI CMP performances.

    Science.gov (United States)

    Kim, Ye-Hwan; Kim, Sang-Kyun; Kim, Namsoo; Park, Jea-Gun; Paik, Ungyu

    2008-09-01

    The effect of the crystalline structures of nano-sized ceria particles on shallow trench isolation (STI) chemical mechanical planarization (CMP) performance was investigated. The ceria particles were synthesized via a solid-state displacement reaction method, and their crystalline structure was controlled by regulating the oxygen partial pressure at the reaction site on the precursor. The crystalline structures of ceria particles were analyzed by the high-resolution TEM nano-beam diffraction pattern. In a calcination process with a high oxygen concentration, the synthesized ceria particles had a cubic fluorite structure (CeO(2)), because of the decarbonation of the cerium precursor. However, a low oxygen concentration results in a hexagonal phase cerium oxide (Ce(2)O(3)) rather than the cubic phase due to the insufficient oxidation of Ce(3+) to Ce(4+). In the STI CMP evaluation, the ceria slurry prepared with the cubic CeO(2) shows enhanced performances of the oxide-to-nitride removal selectivity.

  7. Effect of Nickel Levels on Hydrogen Partial Pressure and Methane Production in Methanogens

    Science.gov (United States)

    2016-01-01

    Hydrogen (H2) consumption and methane (CH4) production in pure cultures of three different methanogens were investigated during cultivation with 0, 0.2 and 4.21 μM added nickel (Ni). The results showed that the level of dissolved Ni in the anaerobic growth medium did not notably affect CH4 production in the cytochrome-free methanogenic species Methanobacterium bryantii and Methanoculleus bourgensis MAB1, but affected CH4 formation rate in the cytochrome-containing Methanosarcina barkeri grown on H2 and CO2. Methanosarcina barkeri also had the highest amounts of Ni in its cells, indicating that more Ni is needed by cytochrome-containing than by cytochrome-free methanogenic species. The concentration of Ni affected threshold values of H2 partial pressure (pH2) for all three methanogen species studied, with M. bourgensis MAB1 reaching pH2 values as low as 0.1 Pa when Ni was available in amounts used in normal anaerobic growth medium. To our knowledge, this is the lowest pH2 threshold recorded to date in pure methanogen culture, which suggests that M.bourgensis MAB1 have a competitive advantage over other species through its ability to grow at low H2 concentrations. Our study has implications for research on the H2-driven deep subsurface biosphere and biogas reactor performance. PMID:27992585

  8. Fiber-optic fluorescence-quenching oxygen partial pressure sensor using platinum octaethylporphyrin.

    Science.gov (United States)

    Davenport, John J; Hickey, Michelle; Phillips, Justin P; Kyriacou, Panayiotis A

    2016-07-20

    The development and bench testing of a fiber-optic oxygen sensor is described. The sensor is designed for measurement of tissue oxygen levels in the mucosa of the digestive tract. The materials and construction are optimized for insertion through the mouth for measurement in the lower esophagus. An oxygen-sensitive fluorescence-quenching film was applied as a solution of platinum octaethylporphyrin (PtOEP) poly(ethyl methacrylate) (PEMA) and dichloromethane and dip coated onto the distal tip of the fiber. The sensor was tested by comparing relative fluorescence when immersed in liquid water at 37°C, at a range of partial pressures (0-101 kPa). Maximum relative fluorescence at most oxygen concentrations was seen when the PtOEP concentration was 0.1  g.L-1, four layers of coating solution were applied, and a fiber core radius of 600 μm was selected, giving a Stern-Volmer constant of 0.129  kPa-1. The performance of the sensor is suitable for many in vivo applications, particularly mucosal measurements. It has sufficient sensitivity, is sterilizable, and is sufficiently flexible and robust for insertion via the mouth without damage to the probe or risk of harm to the patient.

  9. Spectroscopic study of partially-ordered semiconductor heterojunction under high pressure and high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Yu, P.Y.; Martinez, G.; Zeman, J.; Uchida, K.

    2000-12-31

    Photoluminescence upconversion (PLU) is a phenomenon in which a sample emits photons with energy higher than that of the excitation photon. This effect has been observed in many materials including rare earth ions doped in insulating hosts and semiconductor heterostructures without using high power lasers as the excitation source. Recently, this effect has been observed also in partially CuPt-ordered GaInP{sub 2} epilayers grown on GaAs substrates. As a spectroscopic technique photoluminescence upconversion is particularly well suited for studying band alignment at heterojunction interface. The value of band-offset has been determined with meV precision using magneto-photoluminescence. Using the fact that the pressure coefficient of electrons in GaAs is higher than those in GaInP{sub 2} they have been able to manipulate the band-offset at the GaInP/GaAs interface. By converting the band-offset from Type I to Type II they were able to demonstrate that the efficiency of the upconversion process is greatly enhanced by a Type II band-offset.

  10. Choking under monitoring pressure: being watched by the experimenter reduces executive attention.

    Science.gov (United States)

    Belletier, Clément; Davranche, Karen; Tellier, Idriss S; Dumas, Florence; Vidal, Franck; Hasbroucq, Thierry; Huguet, Pascal

    2015-10-01

    Performing more poorly given one's skill level ("choking") is likely in situations that offer an incentive if a certain outcome is achieved (outcome pressure) or when one is being watched by others-especially when one's performance is being evaluated (monitoring pressure). According to the choking literature, outcome pressure is associated with reduced executive control of attention, whereas monitoring pressure is associated with increased, yet counterproductive, attention to skill processes. Here, we show the first evidence that monitoring pressure-being watched by the experimenter-may lead individuals with higher working memory to choke on a classic measure of executive control-just the task effect thought to result from outcome pressure. Not only does this finding help refine our understanding of the processes underlying choking under monitoring pressure, but it also leads to a new look at classic audience effects, with an important implication for experimental psychology.

  11. Twenty-Four-Hour Ambulatory Blood Pressure Monitoring in Hypertension

    Science.gov (United States)

    2012-01-01

    Executive Summary Objective The objective of this health technology assessment was to determine the clinical effectiveness and cost-effectiveness of 24-hour ambulatory blood pressure monitoring (ABPM) for hypertension. Clinical Need: Condition and Target Population Hypertension occurs when either systolic blood pressure, the pressure in the artery when the heart contracts, or diastolic blood pressure, the pressure in the artery when the heart relaxes between beats, are consistently high. Blood pressure (BP) that is consistently more than 140/90 mmHg (systolic/diastolic) is considered high. A lower threshold, greater than 130/80 mmHg (systolic/diastolic), is set for individuals with diabetes or chronic kidney disease. In 2006 and 2007, the age-standardized incidence rate of diagnosed hypertension in Canada was 25.8 per 1,000 (450,000 individuals were newly diagnosed). During the same time period, 22.7% of adult Canadians were living with diagnosed hypertension. A smaller proportion of Canadians are unaware they have hypertension; therefore, the estimated number of Canadians affected by this disease may be higher. Diagnosis and management of hypertension are important, since elevated BP levels are related to the risk of cardiovascular disease, including stroke. In Canada in 2003, the costs to the health care system related to the diagnosis, treatment, and management of hypertension were over $2.3 billion (Cdn). Technology The 24-hour ABPM device consists of a standard inflatable cuff attached to a small computer weighing about 500 grams, which is worn over the shoulder or on a belt. The technology is noninvasive and fully automated. The device takes BP measurements every 15 to 30 minutes over a 24-to 28-hour time period, thus providing extended, continuous BP recordings even during a patient’s normal daily activities. Information on the multiple BP measurements can be downloaded to a computer. The main detection methods used by the device are auscultation and

  12. [Monitoring trends in fixed partial denture design based on national surveys].

    Science.gov (United States)

    Fejérdy, Pál; Tollas, Ors Lehel; Fejérdy, László; Borbély, Judit; Hermann, Peter

    2007-12-01

    partial dentures provide a sound basis for estimating the present oral health status of the population. Monitoring patterns of change have an important epidemiological relevance. Results of our present findings serve as a reliable source to plan future strategy of the dental care system and also helps to measure efficiency of the dental education system.

  13. A Wireless Pressure Sensor for Continuous Monitoring of Intraocular Pressure in Conscious Animals.

    Science.gov (United States)

    Bello, Simon A; Passaglia, Christopher L

    2017-08-15

    An important aspect of eye health in humans and animal models of human diseases is intraocular pressure (IOP). IOP is typically measured by hand with a tonometer, so data are sparse and sporadic and round-the-clock variations are not well characterized. Here we present a novel system for continuous wireless IOP and temperature measurement in small animals. The system consists of a cannula implanted in the anterior chamber of the eye connected to pressure sensing electronics that can be worn by rats or implanted in larger mammals. The system can record IOP with 0.3 mmHg accuracy and negligible drift at a rate of 0.25 Hz for 1-2 months on a regulated battery or indefinitely at rates up to 250 Hz via RF energy harvesting. Chronic recordings from conscious rats showed that IOP follows a diurnal rhythm, averaging 16.5 mmHg during the day and 21.7 mmHg at night, and that the IOP rhythm lags a diurnal rhythm in body temperature by 2.1 h. IOP and body temperature fluctuations were positively correlated from moment-to-moment as well. This technology allows researchers to monitor for the first time the precise IOP history of rat eyes, a popular model for glaucoma studies.

  14. End-tidal arterial CO2 partial pressure gradient in patients with severe hypercapnia undergoing noninvasive ventilation

    Directory of Open Access Journals (Sweden)

    Defilippis V

    2013-06-01

    Full Text Available Vito Defilippis,1 Davide D’Antini,2 Gilda Cinnella,2 Michele Dambrosio,2 Fernando Schiraldi,3 Vito Procacci1 1Emergency Department, Riuniti Hospital, 2Department of Anaesthesiology and Intensive Care, University of Foggia, Foggia, 3Emergency Department, San Paolo Hospital, Naples, Italy Background: Patients with severe hypercapnia represent a particularly serious condition in an emergency department (ED, requiring immediate attention. Noninvasive ventilation (NIV is an integral part of the treatment for acute respiratory failure. The present study aimed to validate the measurement of end-tidal CO2 (EtCO2 as a noninvasive technique to evaluate the effectiveness of NIV in acute hypercapnic respiratory failure. Methods: Twenty consecutive patients admitted to the ED with severe dyspnea were enrolled in the study. NIV by means of bilevel positive airway pressure, was applied to the patients simultaneously with standard medical therapy and continued for 12 hours; the arterial blood gases and side-stream nasal/oral EtCO2 were measured at subsequent times: T0 (admission to the ED, T1h (after 1 hour, T6h (after 6 hours, and T12h (after 12 hours during NIV treatment. Results: The arterial CO2 partial pressure (PaCO2–EtCO2 gradient decreased progressively, reaching at T6h and T12h values lower than baseline (P < 0.001, while arterial pH increased during the observation period (P < 0.001. A positive correlation was found between EtCO2 and PaCO2 values (r = 0.89, P < 0.001 at the end of the observation period. Conclusion: In our hypercapnic patients, the effectiveness of the NIV was evidenced by the progressive reduction of the PaCO2–EtCO2 gradient. The measurement of the CO2 gradient could be a reliable method in monitoring the effectiveness of NIV in acute hypercapnic respiratory failure in the ED. Keywords: arterial end-tidal CO2 gradient, noninvasive ventilation, bilevel positive airway pressure, acute respiratory failure

  15. European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring

    NARCIS (Netherlands)

    Parati, Gianfranco; Stergiou, George; O'Brien, Eoin; Asmar, Roland; Beilin, Lawrence; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M; Shennan, Andrew; Staessen, Jan A; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2014-01-01

    Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published

  16. Monitoring intracranial pressure utilizing a novel pattern of brain multiparameters in the treatment of severe traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Sun H

    2016-06-01

    Full Text Available Hong-tao Sun,1,* Maohua Zheng,2,* Yanmin Wang,1 Yunfeng Diao,1 Wanyong Zhao,1 Zhengjun Wei1 1Sixth Department of Neurosurgery, Affiliated Hospital of Logistics University of People’s Armed Police Force, Tianjin, 2Department of Neurosurgery, The First Hospital of Lanzhou University, Lanzhou, People’s Republic of China *These authors contributed equally to this work Abstract: The aim of the study was to evaluate the clinical value of multiple brain parameters on monitoring intracranial pressure (ICP procedures in the therapy of severe traumatic brain injury (sTBI utilizing mild hypothermia treatment (MHT alone or a combination strategy with other therapeutic techniques. A total of 62 patients with sTBI (Glasgow Coma Scale score <8 were treated using mild hypothermia alone or mild hypothermia combined with conventional ICP procedures such as dehydration using mannitol, hyperventilation, and decompressive craniectomy. The multiple brain parameters, which included ICP, cerebral perfusion pressure, transcranial Doppler, brain tissue partial pressure of oxygen, and jugular venous oxygen saturation, were detected and analyzed. All of these measures can control the ICP of sTBI patients to a certain extent, but multiparameters associated with brain environment and functions have to be critically monitored simultaneously because some procedures of reducing ICP can cause side effects for long-term recovery in sTBI patients. The result suggested that multimodality monitoring must be performed during the process of mild hypothermia combined with conventional ICP procedures in order to safely target different clinical methods to specific patients who may benefit from an individual therapy. Keywords: mild hypothermia treatment, cerebral perfusion pressure, brain tissue partial pressure of oxygen

  17. Equilibrium relationships in the uranium-tungsten-oxygen system in oxygen partial pressures from 0. 01 to 1 atm

    Energy Technology Data Exchange (ETDEWEB)

    Gadalla, A.M.; Mansour, N.A.L.

    1985-07-01

    Equilibrium relationships in the uranium-tungsten-oxygen system have been established as a function of temperature at different oxygen pressures. Isobaric sections in air and oxygen and oxygen partial pressures of 0.01 and 0.07 were constructed, using the thermobalance. Mixtures of U3O8 and WO3 pick up weight in air, forming UWO6, which exists over a wide range of compositions taking both uranium oxides and WO3 in solid solution. The compound WO3 takes a limited amount of uranium oxide in solid solution and U3O8 also dissolves a limited amount of WO3 The miscibility gap between the solid solutions of UWO/sub 6-x/ and U3O/sub 8-y/ on the one hand and the solid solutions of UWO/sub 6-x/ and WO/sub 3-z/ on the other hand decreases by decreasing oxygen partial pressure and/or by increasing temperature. Each group of compatible solutions finally merges into a single phase deficient in oxygen. The two single phases exist over a wide range of compositions and melt over ranges of temperatures depending on the initial composition. Above a critical oxygen partial pressure (between 0.01 and 0.07 atm), solid solutions of UWO/sub 6-x/ and U3O/sub 8-y/, as well as solid solutions of UWO/sub 6-x/ and WO/sub 3-z/, melt partially with isothermal oxygen loss. Increasing the oxygen partial pressure increases the melting temperatures and produces eutectic liquids richer in oxygen.

  18. The effect of different atmospheric ozone partial pressures on photosynthesis and growth of nine fruit and nut tree species.

    Science.gov (United States)

    Retzlaff, W A; Williams, L E; DeJong, T M

    1991-01-01

    Nursery stock of peach (Prunus persica L. Batsch, cv. O'Henry), nectarine (P. persica L. Batsch, cv. Fantasia), plum (P. salicina Lindel., cv. Casselman), apricot (P. armeniaca L., cv. Tilton), almond (P. dulcis Mill., cv. Nonpareil), prune (P. domestica L., cv. Improved French), cherry (P. avium L., cv. Bing), oriental pear (Pyrus pyrifolia Rehd., cv. 20th Century), and apple (Malus pumula Mill., cv. Granny Smith) were planted in open-top chambers on April 1, 1988 at the University of California's Kearney Agricultural Center located in the San Joaquin Valley (30 degrees 40' N 119 degrees 40' W). Trees were exposed to three atmospheric ozone partial pressures (charcoal-filtered air (C), ambient air (A), or ambient air + ozone (T)) from August 1 to November 17, 1988. The mean 12-h (0800 to 2000 h) ozone partial pressures measured in open-top chambers during the experimental period were 0.030, 0.051, and 0.117 microPa Pa(-1) in the C, A and T treatments, respectively. Leaf net CO(2) assimilation rate decreased linearly with increasing 12-h mean ozone partial pressure for the almond, plum, apricot, prune, pear, and apple cultivars. Stomatal conductances of apricot, apple, almond, and plum decreased linearly with increasing ozone partial pressure. Cross-sectional area relative growth rates of almond, plum, apricot, and pear decreased linearly with increasing ozone partial pressure. Net CO(2) assimilation rate, stomatal conductance, and trunk growth of cherry, peach and nectarine were unaffected by the ozone treatments. Reduced leaf gas exchange probably contributed to ozone-induced growth reduction of the susceptible species and cultivars. Several of the commercial fruit tree species and cultivars studied were relatively tolerant to the ozone treatments.

  19. Does home blood pressure monitoring improve patient outcomes? A systematic review comparing home and ambulatory blood pressure monitoring on blood pressure control and patient outcomes

    Directory of Open Access Journals (Sweden)

    Breaux-Shropshire TL

    2015-07-01

    Full Text Available Tonya L Breaux-Shropshire,1,2 Eric Judd,1 Lee A Vucovich,3 Toneyell S Shropshire,4 Sonal Singh5 1Vascular Biology and Hypertension Program, Cardiovascular Disease, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA; 2Veterans Administration, Birmingham, AL, USA; 3Lister Hill Library, University of Alabama at Birmingham, Birmingham, AL, USA; 4Department of Physical Therapy, Louisiana State University Health Sciences Center, New Orleans, LA, USA; 5Department of Medicine, John Hopkins School of Medicine, Baltimore, MD, USA Objective: Our objective was to compare the clinical effectiveness of home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM on blood pressure (BP control and patient outcomes. Design: A systematic review was conducted. We also appraised the methodological quality of studies. Data sources: PubMed, Scopus, CINAHL, and the Cochrane Central Register of Control Trials (CENTRAL. Inclusion criteria: Randomized control trials, prospective and retrospective cohort studies, observational studies, and case-control studies published in English from any year to present that describe HBPM and 24-hour ABPM and report on systolic and/or diastolic BP and/or heart attack, stroke, kidney failure and/or all-cause mortality for adult patients. Due to the nature of the question, studies with only untreated patients were not considered. Results: Of 1,742 titles and abstractions independently reviewed by two reviewers, 137 studies met predetermined criteria for evaluation. Nineteen studies were identified as relevant and included in the paper. The common themes were that HBPM and ABPM correlated with cardiovascular events and mortality, and targeting HBPM or ABPM resulted in similar outcomes. Associations between BP measurement type and mortality differed by study population. Both the low sensitivity of office blood pressure monitoring (OBPM to detect optimal BP control by ABPM and the

  20. Wearable Beat to Beat Blood Pressure Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during the space missions. The wearable physiological monitor...

  1. Brachial Arterial Pressure Monitoring during Cardiac Surgery Rarely Causes Complications.

    Science.gov (United States)

    Singh, Asha; Bahadorani, Bobby; Wakefield, Brett J; Makarova, Natalya; Kumar, Priya A; Tong, Michael Zhen-Yu; Sessler, Daniel I; Duncan, Andra E

    2017-06-01

    Brachial arterial catheters better estimate aortic pressure than radial arterial catheters but are used infrequently because complications in a major artery without collateral flow are potentially serious. However, the extent to which brachial artery cannulation promotes complications remains unknown. The authors thus evaluated a large cohort of cardiac surgical patients to estimate the incidence of related serious complications. The institutional Society of Thoracic Surgeons Adult Cardiac Surgery Database and Perioperative Health Documentation System Registry of the Cleveland Clinic were used to identify patients who had brachial artery cannulation between 2007 and 2015. Complications within 6 months after surgery were identified by International Classification of Diseases, Ninth Revision diagnostic and procedural codes, Current Procedural Terminology procedure codes, and Society of Thoracic Surgeons variables. The authors reviewed electronic medical records to confirm that putative complications were related plausibly to brachial arterial catheterization. Complications were categorized as (1) vascular, (2) peripheral nerve injury, or (3) infection. The authors evaluated associations between brachial arterial complications and patient comorbidities and between complications and in-hospital mortality and duration of hospitalization. Among 21,597 qualifying patients, 777 had vascular or nerve injuries or local infections, but only 41 (incidence 0.19% [95% CI, 0.14 to 0.26%]) were potentially consequent to brachial arterial cannulation. Vascular complications occurred in 33 patients (0.15% [0.10 to 0.23%]). Definitely or possibly related infection occurred in 8 (0.04% [0.02 to 0.08%]) patients. There were no plausibly related neurologic complications. Peripheral arterial disease was associated with increased risk of complications. Brachial catheter complications were associated with prolonged hospitalization and in-hospital mortality. Brachial artery cannulation for

  2. Suction pressure, yield strength and effective stress of partially saturated unbound granular pavement layers

    CSIR Research Space (South Africa)

    Theyse, HL

    2006-09-01

    Full Text Available that includes an approximation of the suction pressure in the formulation of the model. The suction pressure approximation is extended to include the effect of density on the suction pressure. The calibration of the suction pressure approximation and yield...

  3. Pressure of a partially ionized hydrogen gas: numerical results from exact low temperature expansions

    Energy Technology Data Exchange (ETDEWEB)

    Alastuey, A. [Laboratoire de Physique, ENS Lyon, CNRS, Lyon (France); Ballenegger, V. [Institut UTINAM, Universite de Franche-Comte, CNRS, Besancon (France)

    2010-01-15

    We consider a partially ionized hydrogen gas at low densities, where it reduces almost to an ideal mixture made with hydrogen atoms in their ground-state, ionized protons and ionized electrons. By performing systematic low-temperature expansions within the physical picture, in which the system is described as a quantum electron-proton plasma interacting via the Coulomb potential, exact formulae for the first.ve leading corrections to the ideal Saha equation of state have been derived[A. Alastuey, V. Ballenegger et al., J. Stat. Phys. 130, 1119 (2008)]. Those corrections account for all effects of interactions and thermal excitations up to order exp(E{sub H} /kT) included, where E{sub H} {approx_equal} -13.6 eV is the ground state energy of the hydrogen atom. Among the.ve leading corrections, three are easy to evaluate, while the remaining ones involve suitably truncated internal partition functions of H{sub 2} molecules and H{sup -} and H{sub 2}{sup +} ions, for which no analytical formulae are available in closed form. We estimate those partitions functions at.nite temperature via a simple phenomenology based on known values of rotational and vibrational energies. This allows us to compute numerically the leading deviations to the Saha pressure along several isotherms and isochores. Our values are compared with those of the OPAL tables (for pure hydrogen) calculated within the ACTEX method (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Resting and post bronchial challenge testing carbon dioxide partial pressure in individuals with and without asthma.

    Directory of Open Access Journals (Sweden)

    David Miedinger

    Full Text Available OBJECTIVE: There is conflicting evidence about resting carbon dioxide levels in asthmatic individuals. We wanted to determine if transcutaneously measured carbon dioxide levels prior and during bronchial provocation testing differ according to asthma status reflecting dysfunctional breathing. METHODS: We investigated active firefighters and policemen by means of a validated questionnaire on respiratory symptoms, spirometry, bronchial challenge testing with methacholine (MCT and measurement of transcutaneous blood carbon dioxide partial pressure (PtcCO(2 at rest prior performing spirometry, one minute and five minutes after termination of MCT. A respiratory physician blinded to the PtcCO(2 results assigned a diagnosis of asthma after reviewing the available study data and the files of the workers medical screening program. RESULTS: The study sample consisted of 128 male and 10 female individuals. Fifteen individuals (11% had physician-diagnosed asthma. There was no clinically important difference in median PtcCO(2 at rest, one and five minutes after recovery from MCT in asthmatics compared to non-asthmatics (35.6 vs 35.7 mmHg, p = 0.466; 34.7 vs 33.4 mmHg, p = 0.245 and 37.4 vs 36.4 mmHg, p = 0.732. The median drop in PtcCO(2 during MCT and the increase after MCT was lower in asthmatics compared to non-asthmatics (0.1 vs 3.2 mmHg, p = 0.014 and 1.9 vs 2.9 mmHg, p = 0.025. CONCLUSIONS: PtcCO(2 levels at rest prior and during recovery after MCT do not differ in individuals with or without physician diagnosed asthma. The fall and subsequent increase in PtcCO(2 levels are higher in non-asthmatics than in asthmatics and seems to be related with increased number of respiratory maneuvers during MCT.

  5. Study on changes of partial pressure of brain tissue oxygen and brain temperature in acute phase of severe head injury during mild hypothermia therapy

    Institute of Scientific and Technical Information of China (English)

    朱岩湘; 姚杰; 卢尚坤; 章更生; 周关仁

    2003-01-01

    Objective: To study the changes of partial pressure of brain tissue oxygen (PbtO2) and brain temperature in acute phase of severe head injury during mild hypothermia therapy and the clinical significance.Methods: One hundred and sixteen patients with severe head injury were selected and divided into a mild hypothermia group (n=58), and a control group (n=58) according to odd and even numbers of hospitalization. While mild hypothermia therapy was performed PbtO2 and brain temperature were monitored for 1-7 days (mean=86 hours), simultaneously, the intracranial pressure, rectum temperature, cerebral perfusion pressure, PaO2 and PaCO2 were also monitored. The patients were followed up for 6 months and the prognosis was evaluated with GOS (Glasgow outcome scale).Results: The mean value of PbtO2 within 24 hour monitoring in the 116 patients was 13.7 mm Hg±4.94 mm Hg, lower than the normal value (16 mm Hg±40 mm Hg) The time of PbtO2 recovering to the normal value in the mild hypothermia group was shortened by 10±4.15 hours compared with the control group (P<0.05). The survival rate of the mild hypothermia group was 60.43%, higher than that of the control group (46.55%). After the recovery of the brain temperature, PbtO2 increased with the rise of the brain temperature. Conclusions: Mild hypothermia can improve the survival rate of severe head injury. The technique of monitoring PbtO2 and the brain temperature is safe and reliable, and has important clinical significance in judging disease condition and instructing clinical therapy.

  6. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.

    Science.gov (United States)

    Mignini, Mariano Alejandro; Piacentini, Enrique; Dubin, Arnaldo

    2006-01-01

    Invasive arterial blood pressure monitoring is a common practice in intensive care units (ICUs). Accuracy of invasive blood pressure monitoring is crucial in evaluating the cardiocirculatory system and adjusting drug therapy for hemodynamic support. However, the best site for catheter insertion is controversial. Lack of definitive information in critically ill patients makes it difficult to establish guidelines for daily practice in intensive care. We hypothesize that peripheral and central mean arterial blood pressures are interchangeable in critically ill patients. This is a prospective, observational study carried out in a surgical-medical ICU in a teaching hospital. Fifty-five critically ill patients with clinical indication of invasive arterial pressure monitoring were included in the study. No interventions were made. Simultaneous measurements were registered in central (femoral) and peripheral (radial) arteries. Bias and precision between both measurements were calculated with Bland-Altman analysis for the whole group. Bias and precision were compared between patients receiving high doses of vasoactive drugs (norepinephrine or epinephrine >0.1 microg/kg/minute or dopamine >10 microg/kg/minute) and those receiving low doses (norepinephrine or epinephrine arterial pressure was 3 +/- 4 mmHg higher than peripheral mean arterial pressure for the whole population and there were no differences between groups (3 +/- 4 mmHg for both groups). Measurement of mean arterial blood pressure in radial or femoral arteries is clinically interchangeable. It is not mandatory to cannulate the femoral artery, even in critically ill patients receiving high doses of vasoactive drugs.

  7. In-Situ Partial Pressure Measurements and Visual Observation during Crystal Growth of ZnSe by Seeded Physical Vapor Transport

    Science.gov (United States)

    Su, Ching-Hua; Feth, Shari; Lehoczky, Sandor L.

    1999-01-01

    An in-situ monitoring furnace was constructed with side windows to perform partial pressure measurements by optical absorption and visual observation of the growing crystal. A fused silica -rowth ampoule with a 4.5 cm long square tube between the source and the seed was prepared for the optical absorption measurements. A ZnSe crystal was grown by the seeded physical vapor transport (PVT) technique in the horizontal configuration. The growth temperature was 1120 C and the furnace translation rate was 3nmVday. Partial pressures of Se2, P(sub Se2), at three locations along the length of the growth ampoule were measured at 90 min intervals during the growth process. The measured P (sub Se2) were in the range of 2.0 to 6.5 x 10(exp -3) atm. The P(sub Se2) results indicated that the partial pressure profile was inconsistent with the results of the one-dimensional diffusion mass transport model and that the source composition shifted toward Se-rich during the run, i.e. the grown crystal was more Zn-rich than the source. The visual observation showed that the seed crystal first etched back, with greater thermal etching occurring along the edges of the seed crystal. Once the growth started, the crystal crew in a predominately contactless mode and facets were evident during growth. The crystal did not grow symmetrically which is believed to be due to the unintentional asymmetry of the radial thermal profile in the furnace.

  8. Accuracy in Blood Pressure Monitoring: The Effect of Noninvasive Blood Pressure Cuff Inflation on Intra-arterial Blood Pressure Values.

    Science.gov (United States)

    Sheshadri, Veena; Tiwari, Akhilesh Kumar; Nagappa, Mahesh; Venkatraghavan, Lashmi

    2017-01-01

    Both invasive and noninvasive blood pressure (invasive arterial blood pressure [IABP] and noninvasive BP [NIBP]) monitors are used perioperatively; however, they often produce different values. The reason for this discrepancy is not clear, and it is possible that the act of cuff inflation itself might affect the IABP values, especially with the recurrent cycling of NIBP cuff. The aim of this study was to determine the effect of ipsilateral NIBP cuff inflation on the contralateral IABP values. Prospective, observational study. One hundred consecutive patients were studied. The NIBP device was set to cycle every 5 min for a total of 6 times. During each cuff inflation cycle, changes in IABP values from the arterial line in the contralateral arm were recorded. A total of 582 measurements were included for data analysis. Chi-square, paired t-test, analysis of variance. Mean (± standard deviation) changes in systolic BP (SBP), diastolic BP, and mean BP with cuff inflation were 6.7 ± 5.9, 2.6 ± 4.0, and 4.0 ± 3.9 mmHg, respectively. We observed an increase of 0-10 mmHg in SBP in majority (73.4%) of cuff inflations. The changes in IABP did not differ between the patients with or without hypertension or with the baseline SBP. This study showed that there is a transient reactive rise in IABP values with NIBP cuff inflation. This is important information in the perioperative and intensive care settings, where both these measurement techniques are routinely used. The exact mechanism for this effect is not known but may be attributed to the pain and discomfort from cuff inflation.

  9. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...

  10. Tissue electrical properties monitoring for the prevention of pressure sore.

    Science.gov (United States)

    Ching, Congo Tak-Shing; Chou, Mei-Yun; Jiang, Siou-Jhen; Huang, Su-Hua; Sun, Tai-Ping; Liu, Wei-Hao; Liu, Chia-Ming

    2011-12-01

    Pressure sores are a significant problem in the healthcare sector. Although they may cause considerable morbidity, they are preventable. The objectives of this study are to (1) investigate the electrical properties of a tissue close to and away from the pressure sore site, and (2) establish a new approach for objective, reliable, low-cost and noninvasive screening or detection of pressure sore in its early stage. Randomised controlled trial. Fifteen patients participated in this study. They all had stage I or stage II sacral pressure sores. Tiny surface electrodes in four-electrode configuration were used for all tissue electrical properties measurements recorded over the frequency range of 30-10 MHz. Intraclass correlation coefficient (ICC) showed that all measurements (ICC > 0.90 for all measurements) had good reliability and validity. The real part of impedance (R) and the imaginary part of impedance (X) of a tissue measured close to the pressure sore site was found to be significantly smaller (p pressure sore site at a specific frequency range (R: 30.00-38.55 Hz; X: 43.95-606.40 Hz). It was also found that the extracellular resistance (R(e)) and the ratio of extracellular resistance to intracellular resistance (R(e)/R(i)) of a tissue measured close to the pressure sore site were significantly smaller (p pressure sore site. Since the electrical properties (R, X, R(e), R(e)/R(i) ) of a tissue close to, and away from, the pressure sore site can be significantly distinguished, a potentially promising method for the screening of pressure sores at an early stage has been proposed.

  11. Drift velocity and pressure monitoring of the CMS muon drift chambers

    CERN Document Server

    Sonnenschein, Lars

    2010-01-01

    The drift velocity in drift tubes of the CMS muon chambers is a key parameter for the muon track reconstruction and trigger. It needs to be monitored precisely in order to detect any deviation from its nominal value. A change in absolute pressure, a variation of the gas admixture or a contamination of the chamber gas by air affect the drift velocity. Furthermore, the temperature and magnetic field influence its value. First data, taken with a dedicated Velocity Drift Chamber (VDC) built by RWTH Aachen IIIA are presented. Another important parameter to be monitored is the pressure inside the muon drift tube chambers because the drift velocity depends on it. Furthermore the differential pressure must not exceed a certain value and the absolute pressure has to be kept slightly above ambient pressure to prevent air from entering into the muon drift tube chambers in case of a leak. Latest pressure monitoring results are discussed.

  12. A comparative study of the centrifugal and vacuum-pressure techniques of casting removable partial denture frameworks.

    Science.gov (United States)

    Shanley, J J; Ancowitz, S J; Fenster, R K; Pelleu, G B

    1981-01-01

    A study was undertaken to evaluate two techniques for casting accuracy on removable partial denture frameworks: centrifugal casting and vacuum-pressure casting. A standard metal die with predetermined reference points in a horizontal plane was duplicated in refractory investment. The casts were waxed, and castings of nickel-chrome alloy were fabricated by the two techniques. Both the casts and the castings were measured between the reference points with a measuring microscope. With both casting methods, the differences between the casts and the castings were significant, but no significant differences were found between castings produced by the two techniques. Vertical measurements at three designated points also showed no significant differences between the castings. Our findings indicate that dental laboratories should be able to use the vacuum-pressure method of casting removable partial denture frameworks and achieve accuracy similar to that obtained by the centrifugal method of casting.

  13. Two Phase Flow Modeling: Summary of Flow Regimes and Pressure Drop Correlations in Reduced and Partial Gravity

    Science.gov (United States)

    Balasubramaniam, R.; Rame, E.; Kizito, J.; Kassemi, M.

    2006-01-01

    The purpose of this report is to provide a summary of state-of-the-art predictions for two-phase flows relevant to Advanced Life Support. We strive to pick out the most used and accepted models for pressure drop and flow regime predictions. The main focus is to identify gaps in predictive capabilities in partial gravity for Lunar and Martian applications. Following a summary of flow regimes and pressure drop correlations for terrestrial and zero gravity, we analyze the fully developed annular gas-liquid flow in a straight cylindrical tube. This flow is amenable to analytical closed form solutions for the flow field and heat transfer. These solutions, valid for partial gravity as well, may be used as baselines and guides to compare experimental measurements. The flow regimes likely to be encountered in the water recovery equipment currently under consideration for space applications are provided in an appendix.

  14. Selective modulation of cellular voltage dependent calcium channels by hyperbaric pressure - a suggested HPNS partial mechanism

    Directory of Open Access Journals (Sweden)

    Ben eAviner

    2014-05-01

    Full Text Available Professional deep sea divers experience motor and cognitive impairment, known as High Pressure Neurological Syndrome (HPNS, when exposed to pressures of 100 msw (1.1MPa and above, considered to be the result of synaptic transmission alteration. Previous studies have indicated modulation of presynaptic Ca2+ currents at high pressure. We directly measured for the first time pressure effects on the currents of voltage dependent Ca2+ channels (VDCCs expressed in Xenopus oocytes. Pressure selectivity augmented the current in CaV1.2 and depressed it in CaV3.2 channels. Pressure application also affected the channels' kinetics, such as ƮRise, ƮDecay. Pressure modulation of VDCCs seems to play an important role in generation of HPNS signs and symptoms.

  15. Data Of Daily Blood Pressure Monitoring In Patients With Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    A.P. Rebrov

    2009-06-01

    Full Text Available The aim of present work is to study the frequency of hypertension and the peculiarity of 24-hour blood pressure monitoring in patients with rheumatoid arthritis. We studied 584 patients with rheumatoid arthritis. Daily blood pressure monitoring was carried out in 46 patients with arthritis and 18 patients with essential hypertension. Frequency of hypertension was higher in patients with arthritis then in general population. Elevation of systolic blood pressure, heart rate and arterial blood pressure adequate decrease at night were developed to associate with advance of the disease.

  16. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ... fitted on the upper arm are generally the most accurate. If you can't find a cuff ...

  17. Tyre pressure monitoring using a dynamical model-based estimator

    Science.gov (United States)

    Reina, Giulio; Gentile, Angelo; Messina, Arcangelo

    2015-04-01

    In the last few years, various control systems have been investigated in the automotive field with the aim of increasing the level of safety and stability, avoid roll-over, and customise handling characteristics. One critical issue connected with their integration is the lack of state and parameter information. As an example, vehicle handling depends to a large extent on tyre inflation pressure. When inflation pressure drops, handling and comfort performance generally deteriorate. In addition, it results in an increase in fuel consumption and in a decrease in lifetime. Therefore, it is important to keep tyres within the normal inflation pressure range. This paper introduces a model-based approach to estimate online tyre inflation pressure. First, basic vertical dynamic modelling of the vehicle is discussed. Then, a parameter estimation framework for dynamic analysis is presented. Several important vehicle parameters including tyre inflation pressure can be estimated using the estimated states. This method aims to work during normal driving using information from standard sensors only. On the one hand, the driver is informed about the inflation pressure and he is warned for sudden changes. On the other hand, accurate estimation of the vehicle states is available as possible input to onboard control systems.

  18. Efficient absorption of SO{sub 2} with low-partial pressures by environmentally benign functional deep eutectic solvents

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Ren, Shuhang [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China); Hou, Yucui [Department of Chemistry, Taiyuan Normal University, Taiyuan, 030031 (China); Wu, Weize, E-mail: wzwu@mail.buct.edu.cn [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China)

    2017-02-15

    Graphical abstract: Environmentally benign deep eutectic solvents (DESs) based on betaine or L-carnitine with ethylene glycol were designed with a function and used to efficiently capture SO{sub 2} with low partial pressures. - Highlights: • Deep eutectic solvents (DESs) were designed with a function to absorb low-conc. SO{sub 2}. • Betaine(Bet) and L-carnitine(L-car) with a functional group were used as H-bond acceptor. • Bet + ethylene glycol (EG) DES and L-car + EG DES are environmentally benign. • L-car + EG DES can absorb 0.644 mol SO{sub 2} per mole L-car (0.37% SO{sub 2}). • L-car + EG DES is a promising absorbent for SO{sub 2} capture. - Abstract: Sulfur dioxide (SO{sub 2}) emitted from the burning of fossil fuels is one of the main air contaminants. In this work, we found that environmentally benign solvents, deep eutectic solvents (DESs) could be designed with a function to absorb low-partial pressure SO{sub 2} from simulated flue gas. Two kinds of biodegradable functional DESs based on betaine (Bet) and L-carnitine (L-car) as hydrogen bond accepters (HBA) and ethylene glycol (EG) as a hydrogen bond donor (HBD) were prepared with mole ratios of HBA to HBD from 1:3 to 1:5, and they were investigated to absorb SO{sub 2} with different partial pressures at various temperatures. The results showed that the two DESs could absorb low-partial pressure SO{sub 2} efficiently. SO{sub 2} absorption capacities of the DESs with HBA/HBD mole ratio of 1:3 were 0.332 mol SO{sub 2}/mol HBA for Bet + EG DES and 0.820 mol SO{sub 2}/mol HBA for L-car + EG DES at 40 °C with a SO{sub 2} partial pressure of 0.02 atm. In addition, the regeneration experiments demonstrated that the absorption capacities of DESs did not change after five absorption and desorption cycles. Furthermore, the absorption mechanism of SO{sub 2} by DESs was studied by FT-IR, {sup 1}H NMR and {sup 13}C NMR spectra. It was found that there are strong acid–base interactions between SO{sub 2} and

  19. An improved flexible telemetry system to autonomously monitor sub-bandage pressure and wound moisture

    National Research Council Canada - National Science Library

    Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H

    2014-01-01

    This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management...

  20. Packaged Capacitive Pressure Sensor System for Aircraft Engine Health Monitoring

    Science.gov (United States)

    Scardelletti, Maximilian C.; Zorman, Christian A.

    2016-01-01

    This paper describes the development of a packaged silicon carbide (SiC) based MEMS pressure sensor system designed specifically for a conventional turbofan engine. The electronic circuit is based on a Clapp-type oscillator that incorporates a 6H-SiC MESFET, a SiCN MEMS capacitive pressure sensor, titanate MIM capacitors, wirewound inductors, and thick film resistors. The pressure sensor serves as the capacitor in the LC tank circuit, thereby linking pressure to the resonant frequency of the oscillator. The oscillator and DC bias circuitry were fabricated on an alumina substrate and secured inside a metal housing. The packaged sensing system reliably operates at 0 to 350 psi and 25 to 540C. The system has a pressure sensitivity of 6.8 x 10E-2 MHzpsi. The packaged system shows negligible difference in frequency response between 25 and 400C. The fully packaged sensor passed standard benchtop acceptance tests and was evaluated on a flight-worthy engine.

  1. Drift velocity and pressure monitoring of the CMS muon drift chambers

    CERN Document Server

    Sonnenschein, Lars

    2011-01-01

    The drift velocity in drift tubes of the CMS muon chambers is a key parameter for the muon track reconstruction and trigger. It needs to be monitored precisely in order to detect any deviation from its nominal value. A change in absolute pressure, a variation of the gas admixture or a contamination of the chamber gas by air affect the drift velocity. Furthermore, the temperature and magnetic field influence its value. First data, taken with a dedicated Velocity Drift Chamber (VDC) built by RWTH Aachen IIIA are presented. Another important parameter to be monitored is the pressure inside the muon drift tube chambers. The differential pressure must not exceed a certain value and the absolute pressure has to be kept slightly above ambient pressure to prevent air from entering into the muon drift tube chambers in case of a leak. Latest drift velocity monitoring results are discussed.

  2. Electrostatic discharges and their effect on the validity of registered values in intracranial pressure monitors

    DEFF Research Database (Denmark)

    Andresen, Morten; Thomsen, Ole Cornelius; Juhler, Marianne

    2013-01-01

    , the authors have tried to determine if the ICP monitors from major manufacturers were affected by electrostatic discharges (ESDs), if the changes were permanent or transient in nature, and if the changes were modified by the addition of different electrical appliances normally used in the neurointensive care...... unit environment. Methods The authors established a test setup in the neurointensive care unit using a large container filled with isotonic saline, creating a phantom patient. Intracranial pressure monitors were sequentially lowered into the container and subjected to a predefined test battery of ESDs....... Results Five pressure monitors from 4 manufacturers were evaluated. Three monitors containing electrical circuitry at the tip of the transducer were all affected by ESDs. Clinically significant permanent changes in the reported ICP values for 1 pressure monitor were observed, as well as temporary...

  3. A new state-observer of the inner PEM fuel cell pressures for enhanced system monitoring

    Science.gov (United States)

    Bethoux, Olivier; Godoy, Emmanuel; Roche, Ivan; Naccari, Bruno; Amira Taleb, Miassa; Koteiche, Mohamad; Nassif, Younane

    2014-06-01

    In embedded systems such as electric vehicles, Proton exchange membrane fuel cell (PEMFC) has been an attractive technology for many years especially in automotive applications. This paper deals with PEMFC operation monitoring which is a current target for improvement for attaining extended durability. In this paper, supervision of the PEMFC is done using knowledge-based models. Without extra sensors, it enables a clear insight of state variables of the gases in the membrane electrode assembly (MEA) which gives the PEMFC controller the ability to prevent abnormal operating conditions and associated irreversible degradations. First, a new state-observer oriented model of the PEM fuel cell is detailed. Based on this model, theoretical and practical observability issues are discussed. This analysis shows that convection phenomena can be considered negligible from the dynamic point of view; this leads to a reduced model. Finally a state-observer enables the estimation of the inner partial pressure of the cathode by using only the current and voltage measurements. This proposed model-based approach has been successfully tested on a PEM fuel cell simulator using a set of possible fault scenarios.

  4. In Vitro and in vivo characterization of wireless and passive micro system enabling gastrointestinal pressure monitoring.

    Science.gov (United States)

    Shi, Qiang; Wang, Junbo; Chen, Deyong; Chen, Jian; Li, Jing; Bao, Kaikai

    2014-12-01

    This paper presents a wireless and passive micro pressure system based on the LC mutual inductance detection mechanism for gastrointestinal (GI) pressure monitoring. The micro pressure system is composed of a sensor capsule (a pressure sensitive micro capacitive sensor in series with an induction coil to form an LC tank) and a detection unit (a detection coil connected with a network analyzer). The pressure variations under measurement lead to changes in the capacitance of the pressure sensor and therefore a shift in the LC tank resonant frequency, quantified by the impedance measurement of the detection coil. The pressure sensor was fabricated using microfabrication processes with key parameters optimized. The in vitro characterization of the micro pressure system recorded a sensitivity of 0.2491 kHz/kPa (-10 kPa to 30 kPa). One-month rabbit stomach pressure monitoring was conducted based on the developed micro pressure system as a confirmation of device long term in vivo stability. Furthermore, rabbit stomach pressure variations before and after food feeding was recorded and compared where three distinctive contraction patterns (random contraction with low amplitude, irregular strong contractions and regular contraction in a cyclic manner) following food feeding were located. Compared to previous reported GI pressure sensors, this LC tank is featured with simple device structure without batteries and electrical components for energy transfer. Both in vitro and in vivo characterization confirm the functionality of the system, which may enable the gastrointestinal motility study in the near future.

  5. The DPSIR Framework and a Pressure-Oriented Water Quality Monitoring Approach to Ecological River Restoration

    Directory of Open Access Journals (Sweden)

    Björn Frostell

    2012-09-01

    Full Text Available Without monitoring anthropogenic pressures on the water environment, it is difficult to set realistic river restoration targets in relation to water quality. Therefore a more holistic approach is needed to systematically explore the links between socio-economic drivers and observed water quality-related impacts on river ecosystems. Using the DPSIR (Drivers-Pressures-State of the Environment-Impacts-Responses framework, this study linked ecological river restoration with the socio-economic sector, with the focus on promoting a pressure-oriented water quality monitoring system. Based on the European Water Framework Directive (WFD and relevant literature, it was found that most water quality-related indicators employed today are state/impacts-oriented, while very few are pressure-oriented. As a response, we call for more attention to a DPR (Drivers-Pressures-Responses framework in developing an industrial ecology-based pressure-oriented water quality monitoring system for aiding ecological river restoration planning. This approach is characterized in general by accounting for material-related flows throughout the socio-economic sector in relation to river ecosystem degradation. Then the obtained information would help decision makers take appropriate measures to alleviate various significant human-induced wastes and emissions at their sources. We believe that such a pressure-oriented monitoring system will substantially complement traditional state/impacts-oriented environmental and ecological monitoring and help develop more proactive planning and decision-making processes for specific river restoration projects and general water quality management.

  6. Patient Blood Pressure and Pulse Rate Monitoring With an Alert ...

    African Journals Online (AJOL)

    2012-12-01

    Dec 1, 2012 ... Blood pressure and pulse rate are two of the vital signs of humans and it is ... even from their homes and transfer the readings into the computer ... benefits from Omron's 'IntelliSense' .... (the port number assigned to the smart.

  7. Fluid input control in burned patients with the aid of ultrasonic arterial blood pressure monitoring.

    Science.gov (United States)

    Banssillon, V; Latarjet, J

    1975-01-01

    Arterial blood pressure is nowadays easily and reliably measured with ultrasonic equipment. It correlates well with blood volume, and may therefore be used to guide fluid infusion in burned patients. Monitoring of blood pressure, instead of application of old-fashioned recipes, helps to avoid dangerous situations of hypovolemia or overload.

  8. Noninvasive Subharmonic Pressure Estimation for Monitoring Breast Cancer Response to Neoadjuvant Threapy

    Science.gov (United States)

    2009-09-01

    TITLE AND SUBTITLE Noninvasive Subharmonic Pressure Estimation for Monitoring Breast Cancer 5. FUNDING NUMBERS W81XWH-08-1-0503 6. AUTHOR(S...u sing subharmonic aided p ressure estimation (SHAPE ) to estimate the inte rstitial fluid pressure (IFP) in LABC. To date, in vitr o experiments

  9. Novel Approach for Ensuring Increased Validity in Home Blood Pressure Monitoring

    DEFF Research Database (Denmark)

    Wagner, Stefan Rahr; Toftegaard, Thomas Skjødeberg; Bertelsen, Olav Wedege

    This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure...

  10. Wireless system for monitoring Intra-abdominal pressure in patient with severe abdominal pathology

    Science.gov (United States)

    Sokolovskiy, S. S.; Shtotskiy, Y. V.; Leljanov, A. D.

    2017-01-01

    The paper discusses an experimental design of the wireless system for monitoring intra-abdominal pressure (IAP) using Bluetooth Low Energy technology. The possibility of measuring IAP via the bladder using a wireless pressure sensor with a hydrophobic bacteria filter between the liquid transmitting medium and the sensor element is grounded.

  11. Intracranial Pressure Monitoring as a Part of Multimodal Monitoring Management of Patients with Critical Polytrauma: Correlation between Optimised Intensive Therapy According to Intracranial Pressure Parameters and Clinical Picture

    Science.gov (United States)

    Luca, Loredana; Rogobete, Alexandru Florin; Bedreag, Ovidiu Horea; Sarandan, Mirela; Cradigati, Carmen Alina; Papurica, Marius; Gruneantu, Anelore; Patrut, Raluca; Vernic, Corina; Dumbuleu, Corina Maria; Sandesc, Dorel

    2015-01-01

    Objective Trauma patient requires a complex therapeutic management because of multiple severe injuries or secondary complications. The most significant injury found in patients with trauma is head injury, which has the greatest impact on mortality. Intracranial pressure (ICP) monitoring is required in severe traumatic head injury because it optimises treatment based on ICP values and cerebral perfusion pressure (CPP). Methods From a total of 64 patients admitted in the intensive care unit (ICU) ‘Casa Austria’, from the Polytraumatology Clinic of the Emergency County Hospital “Pius Brinzeu” Timisoara, Romania, between January 2014 and December 2014; only patients who underwent ICP monitoring (n=10) were analysed. The study population was divided into several categories depending on the time passed since trauma to the time of installation of ICP monitoring (24 h). Comparisons were made in terms of the number of days admitted in the ICU and mortality between patients with head injury who benefited and those who did not benefit from ICP monitoring. Results The results show the positive influence of ICP monitoring on the number of admission days in ICU because of the possibility that the number of admission days to augment therapeutic effects in patients who benefited from ICP monitoring reduces by 1.93 days compared with those who did not undergo ICP monitoring. Conclusion ICP monitoring and optimizing therapy according to the ICP and CPP has significant influence on the rate of survival. ICP monitoring is necessary in all patients with head trauma injury according to recent guidelines. The main therapeutic goal in the management of the trauma patient with head injury is to minimize the destructive effects of the associated side effects. PMID:27366538

  12. Plasticity in breathing and arterial blood pressure following acute intermittent hypercapnic hypoxia in infant rat pups with a partial loss of 5-HT neurons.

    Science.gov (United States)

    Magnusson, Jennifer; Cummings, Kevin J

    2015-11-15

    The role of serotonin (5-HT) neurons in cardiovascular responses to acute intermittent hypoxia (AIH) has not been studied in the neonatal period. We hypothesized that a partial loss of 5-HT neurons would reduce arterial blood pressure (BP) at rest, increase the fall in BP during hypoxia, and reduce the long-term facilitation of breathing (vLTF) and BP following AIH. We exposed 2-wk-old, 5,7-dihydroxytryptamine-treated and controls to AIH (10% O2; n = 13 control, 14 treated), acute intermittent hypercapnia (5% CO2; n = 12 and 11), or acute intermittent hypercapnic hypoxia (AIHH; 10% O2, 5% CO2; n = 15 and 17). We gave five 5-min challenges of AIH and acute intermittent hypercapnia, and twenty ∼20-s challenges of AIHH to mimic sleep apnea. Systolic BP (sBP), diastolic BP, mean arterial pressure, heart rate (HR), ventilation (V̇e), and metabolic rate (V̇o2) were continuously monitored. 5,7-Dihydroxytryptamine induced an ∼35% loss of 5-HT neurons from the medullary raphe. Compared with controls, pups deficient in 5-HT neurons had reduced resting sBP (∼6 mmHg), mean arterial pressure (∼5 mmHg), and HR (56 beats/min), and experienced a reduced drop in BP during hypoxia. AIHH induced vLTF in both groups, reflected in increased V̇e and V̇e/V̇o2, and decreased arterial Pco2. The sBP of pups deficient in 5-HT neurons, but not controls, was increased 1 h following AIHH. Our data suggest that a relatively small loss of 5-HT neurons compromises resting BP and HR, but has no influence on ventilatory plasticity induced by AIHH. AIHH may be useful for reversing cardiorespiratory defects related to partial 5-HT system dysfunction.

  13. Effect of mild hypothermia on partial pressure of oxygen in brain tissue and brain temperature in patients with severe head injury

    Institute of Scientific and Technical Information of China (English)

    张赛; 只达石; 林欣; 尚彦国; 牛玉德

    2002-01-01

    Objective: To study the changes of partial pressure of oxygen in brain tissue (PbtO2) and brain temperature (BT) in patients in acute phase of severe head injury, and to study the effect of mild hypothermia on PbtO2 and BT.   Methods: The PbtO2 and the BT of 18 patients with severe head injury were monitored, and the patients were treated with mild hypothermia within 20 hours after injury. The rectal temperature (RT) of the patients was kept on 31.5-34.9℃ for 1-7 days (57.7 hours±28.4 hours averagely), simultaneously, the indexes of PbtO2 and BT were monitored for 1-5 days (with an average of 54.8 hours±27.0 hours). According to Glasgow Outcome Scale (GOS), the prognosis of the patients was evaluated at 6 months after injury.   Results: Within 24 hours after severe head injury, the PbtO2 was significantly lower (9.6 mm Hg±6.8 mm Hg, 1 mm Hg=0.133 kPa) than the normal value (16-40 mm Hg). After treatment of mild hypothermia, the mean PbtO2 increased to 28.7 mm Hg±8.8 mm Hg during the first 24 hours, and the PbtO2 was still maintained within the range of normal value at 3 days after injury. The BT was higher than the RT in the patients in acute phase of severe head injury, and the difference between the BT and the RT significantly increased after treatment of mild hypothermia. Hyperventilation (the partial pressure of carbon dioxide in artery (PaCO2)≈25 mm Hg) decreased the high intracranial pressure (ICP) and significantly decreased the PbtO2.   Conclusions: This study demonstrates that PptO2 and BT monitoring is a safe, reliable and sensitive diagnostic method to follow cerebral oxygenation. It might become an important tool in our treatment regime for patients in the acute phase of severe head injury requiring hypothermia and hyperventilation.

  14. Partial shadowing detection based on equivalent thermal voltage monitoring for PV module diagnostics

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    Partial shadowing of photovoltaic systems can overproportionally reduce the energy yield and lead to early ageing and failure of the shadowed cells. Large area shadows are relatively easy to detect due to the eminent power reduction and decrease of fill factor. However, small area partial shadows...... in a larger system do not have a very obvious effect on the output power or fill factor of the PV array and can remain undetected, leading to failure. In this paper a method for detecting small area partial shadows, based on equivalent thermal voltage, is presented. A simplified expression of the equivalent...

  15. Transpulmonary pressure monitoring during mechanical ventilation: a bench-to-bedside review.

    Science.gov (United States)

    Mietto, Cristina; Malbrain, Manu L N G; Chiumello, Davide

    2015-01-01

    Different ventilation strategies have been suggested in the past in patients with acute respiratory distress syndrome (ARDS). Airway pressure monitoring alone is inadequate to assure optimal ventilatory support in ARDS patients. The assessment of transpulmonary pressure (PTP) can help clinicians to tailor mechanical ventilation to the individual patient needs. Transpulmonary pressure monitoring, defined as airway pressure (Paw) minus intrathoracic pressure (ITP), provides essential information about chest wall mechanics and its effects on the respiratory system and lung mechanics. The positioning of an esophageal catheter is required to measure the esophageal pressure (Peso), which is clinically used as a surrogate for ITP or pleural pressure (Ppl), and calculates the transpulmonary pressure. The benefits of such a ventilation approach are avoiding excessive lung stress and individualizing the positive end-expiratory pressure (PEEP) setting. The aim is to prevent over-distention of alveoli and the cyclic recruitment/derecruitment or shear stress of lung parenchyma, mechanisms associated with ventilator-induced lung injury (VILI). Knowledge of the real lung distending pressure, i.e. the transpulmonary pressure, has shown to be useful in both controlled and assisted mechanical ventilation. In the latter ventilator modes, Peso measurement allows one to assess a patient's respiratory effort, patient-ventilator asynchrony, intrinsic PEEP and the calculation of work of breathing. Conditions that have an impact on Peso, such as abdominal hypertension, will also be discussed briefly.

  16. Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

    OpenAIRE

    Della Rocca, Giorgio; Cecconi, Maurizio; Costa, Maria Gabriella

    2008-01-01

    To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed.Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track change...

  17. Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

    Directory of Open Access Journals (Sweden)

    A. S. Tremsin

    2017-01-01

    Full Text Available Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (∼739 ± 98 kPa and ∼751 ± 154 kPa for two Xe resonances is in relatively good agreement with the pressure value of ∼758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ∼ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others containing various elements opaque to other more conventional imaging techniques. The ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

  18. Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

    Science.gov (United States)

    Tremsin, A. S.; Losko, A. S.; Vogel, S. C.; Byler, D. D.; McClellan, K. J.; Bourke, M. A. M.; Vallerga, J. V.

    2017-01-01

    Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (˜739 ± 98 kPa and ˜751 ± 154 kPa for two Xe resonances) is in relatively good agreement with the pressure value of ˜758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ˜ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others) containing various elements opaque to other more conventional imaging techniques. The ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

  19. A novel method for long-term monitoring of intracranial pressure in rats

    DEFF Research Database (Denmark)

    Uldall, Maria Schmidt; Juhler, Marianne; Skjolding, Anders Daehli;

    2014-01-01

    BACKGROUND: In preclinical neurological studies, monitoring intracranial pressure (ICP) in animal models especially in rodents is challenging. Further, the lack of methods for long-term ICP monitoring has limited the possibilities to conduct prolonged studies on ICP fluctuations in parallel...... and in the epidural space. The two pressures were recorded twice a week for 59 days and the correlation was studied. RESULTS: The two pressure recordings correlated exceptionally well and the R(2) values on each recording day ranged between 0.99 and 1.00. However, the ventricular probes caused a number...

  20. Development and investigation of MOEMS type displacement-pressure sensor for biological information monitoring

    Science.gov (United States)

    Ostasevicius, Vytautas; Malinauskas, Karolis; Janusas, Giedrius; Palevicius, Arvydas; Cekas, Elingas

    2016-04-01

    The aim of this paper is to develop and investigate MOEMS displacement-pressure sensor for biological information monitoring. Developing computational periodical microstructure models using COMSOL Multiphysics modeling software for modal and shape analysis and implementation of these results for design MOEMS displacement-pressure sensor for biological information monitoring was performed. The micro manufacturing technology of periodical microstructure having good diffraction efficiency was proposed. Experimental setup for characterisation of optical properties of periodical microstructure used for design of displacement-pressure sensor was created. Pulsating human artery dynamic characteristics in this paper were analysed.

  1. Integrated solar combined cycles using gas turbines with partial recuperation and solar integration at different pressure levels

    Science.gov (United States)

    Rovira, Antonio; Sánchez, Consuelo; Fernández, Santiago; Muñoz, Marta; Barbero, Rubén

    2017-06-01

    This work studies and compares two alternatives to improve the solar-to-electricity energy conversion efficiency in integrated solar combined cycle power plants (ISCC), which are based on the use of combined cycles including partial recuperative gas turbines. Each alternative has been integrated into dual and triple pressure levels with reheat heat recovery steam generators (HRSG). Partial recuperation conveys lower heat recovery at the steam generator than in conventional plants, because each MW exchanged in the recuperator is not available at the HRSG. This thermal power decrease at the HRSG may be overcome by the integration of solar energy that is implemented using parabolic trough collectors. Moreover, with such an implementation each solar thermal MW integrated allows a MW of heat recuperation and, thus a MW of fossil fuel saving, thus the solar heat-to-electricity energy conversion rate may reach values up to 50 %, which makes the proposal interesting.

  2. Seismic attenuation in partially saturated Berea sandstone submitted to a range of confining pressures

    Science.gov (United States)

    Chapman, Samuel; Tisato, Nicola; Quintal, Beatriz; Holliger, Klaus

    2016-03-01

    Using the forced oscillation method, we measure the extensional-mode attenuation and Young's modulus of a Berea sandstone sample at seismic frequencies (0.5-50 Hz) for varying levels of water saturation (~0-100%) and confining pressures (2-25 MPa). Attenuation is negligible for dry conditions and saturation levels <80%. For saturation levels between ~91% and ~100%, attenuation is significant and frequency dependent in the form of distinct bell-shaped curves having their maxima between 1 and 20 Hz. Increasing saturation causes an increase of the overall attenuation magnitude and a shift of its peak to lower frequencies. On the other hand, increasing the confining pressure causes a reduction in the attenuation magnitude and a shift of its peak to higher frequencies. For saturation levels above ~98%, the fluid pressure increases with increasing confining pressure. When the fluid pressure is high enough to ensure full water saturation of the sample, attenuation becomes negligible. A second series of comparable experiments reproduces these results satisfactorily. Based on a qualitative analysis of the data, the frequency-dependent attenuation meets the theoretical predictions of mesoscopic wave-induced fluid flow (WIFF) in response to a heterogeneous water distribution in the pore space, so-called patchy saturation. These results show that mesoscopic WIFF can be an important source of seismic attenuation at reservoir conditions.

  3. 24-hour ambulatory blood pressure monitoring in children with familial dysautonomia.

    Science.gov (United States)

    Nussinovitch, Naomi; Nussinovitch, Moshe; Peleg, Edna; Rosenthal, Talma

    2005-04-01

    Familial dysautonomia (Riley Day syndrome) is a genetic disease. The present study of 24-hour ambulatory blood pressure monitoring in children with familial dysautonomia was carried out to investigate the pattern of blood pressure in this syndrome. To the best of our knowledge, this is the only description of patients with 24-hour blood pressure monitoring. Vasomotor instability reflected in extreme hypertension and hypotension was recorded by 24-hour ambulatory blood pressure monitoring in three patients with familial dysautonomia: a 16-year old girl, a 14-year old boy and a 3-year old boy. Recordings were taken on a routine school day in the first two patients and during hospitalization in the third. Patients 1 and 2 displayed circadian rhythm but with significantly higher than normal blood pressure and heart rate. Patient 3 exhibited these fluctuations to a lesser degree. Postural hypotension without compensatory tachycardia was frequently seen in all three patients. Unusual variability in blood pressure was recorded during routine activities in patients 1 and 2 and during an acute attack in patient 3. Close monitoring of antihypertensive therapy should be considered in familial dysautonomia patients in whom blood pressure reaches excessive levels.

  4. Influence of oxygen partial pressure on the adsorption and diffusion during oxide growth: ZnO(0001) surface

    Science.gov (United States)

    Ruan, Qiyuan; Ye, Jingchen; Shu, Da-Jun; Wang, Mu

    2017-09-01

    Oxygen partial pressure during vapor phase growth plays a critical role in determining the microstructure and other properties of oxides. However, it remains unclear how it affects the growth mechanism on the atomic scale. In this article, we take ZnO(0001) surface as a model case and demonstrate the influence of oxygen partial pressure on surface adsorption and diffusion of intrinsic adatoms by first-principles calculations. Two typical reconstructions of ZnO(0001) surface, denoted as (2 ×2 ) -O and n3, are utilized to model the oxygen-rich condition and oxygen-poor condition, respectively. The (2 ×2 ) -O refers to the surface with an oxygen adatom in a (2 ×2 ) supercell, while the n3 stands for the surface with triangular pits of edge length n =3 . We find that under the oxygen-rich condition in which (2 ×2 ) -O forms, adsorption of the O adatom is always more energetically favorable than the Zn adatom. Under oxygen-poor condition in which n3 forms, however, the preferential adsorbate changes from O adatom to Zn adatom as the oxygen partial pressure decreases. The O adatom is less diffusive than the Zn adatom on both reconstructed surfaces. The diffusion barriers of both Zn and O on n3 are higher than their counterparts on (2 ×2 ) -O. Insufficient surface diffusion leads to a high nucleation rate; therefore, a second-layer nucleus may form before the completion of the first-layer on n3. It suggests that ZnO growth under oxygen-poor condition, in comparison with the oxygen-rich condition, is more likely to proceed with the three-dimensional island growth mode and result in a rougher surface.

  5. Seed storage at elevated partial pressure of oxygen, a fast method for analysing seed ageing under dry conditions

    Science.gov (United States)

    Groot, S. P. C.; Surki, A. A.; de Vos, R. C. H.; Kodde, J.

    2012-01-01

    Background and Aims Despite differences in physiology between dry and relative moist seeds, seed ageing tests most often use a temperature and seed moisture level that are higher than during dry storage used in commercial practice and gene banks. This study aimed to test whether seed ageing under dry conditions can be accelerated by storing under high-pressure oxygen. Methods Dry barley (Hordeum vulgare), cabbage (Brassica oleracea), lettuce (Lactuca sativa) and soybean (Glycine max) seeds were stored between 2 and 7 weeks in steel tanks under 18 MPa partial pressure of oxygen. Storage under high-pressure nitrogen gas or under ambient air pressure served as controls. The method was compared with storage at 45 °C after equilibration at 85 % relative humidity and long-term storage at the laboratory bench. Germination behaviour, seedling morphology and tocopherol levels were assessed. Key Results The ageing of the dry seeds was indeed accelerated by storing under high-pressure oxygen. The morphological ageing symptoms of the stored seeds resembled those observed after ageing under long-term dry storage conditions. Barley appeared more tolerant of this storage treatment compared with lettuce and soybean. Less-mature harvested cabbage seeds were more sensitive, as was the case for primed compared with non-primed lettuce seeds. Under high-pressure oxygen storage the tocopherol levels of dry seeds decreased, in a linear way with the decline in seed germination, but remained unchanged in seeds deteriorated during storage at 45 °C after equilibration at 85 % RH. Conclusions Seed storage under high-pressure oxygen offers a novel and relatively fast method to study the physiology and biochemistry of seed ageing at different seed moisture levels and temperatures, including those that are representative of the dry storage conditions as used in gene banks and commercial practice. PMID:22967856

  6. Tactile shoe inlays for high speed pressure monitoring

    DEFF Research Database (Denmark)

    Drimus, Alin; Mátéfi-Tempfli, Stefan

    2015-01-01

    pressure sensitive cells and the use of high speed electronics and multiplexing algorithms provides frame rates of 100 Hz. The sensors tolerate overloads while showing a consistent output. The developed prototypes show a high potential not only for robotics, but also for use in sensorised human prosthetics.......This work describes the development of flexible tactile sensor shoe inlays for humanoid robots. Their design is based on a sandwich structure of flexible layers with a thin sheet of piezoresistive rubber as main transducer element. The layout and patterning of top and bottom electrodes give 1024...

  7. Investigation of tunable diode laser absorption spectroscopy for its application as primary standard for partial pressure measurements

    Energy Technology Data Exchange (ETDEWEB)

    Jousten, K; Bock, T [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, D-10587 Berlin (Germany); Padilla-VIquez, G [Laboratorio Costarricense de MetrologIa (Lacomet), Ciudad de la Investigacion de la UCR, San Pedro de Montes de Oca (Costa Rica)], E-mail: Karl.jousten@ptb.de

    2008-03-01

    Partial pressures in vacuum systems can be quite accurately measured by tunable diode laser absorption spectroscopy in the infrared. To examine the possibility for its application as primary standard, for CO{sub 2} in the 2-{mu}m-region we made full traceability to the respective SI unit for each input quantity of the model, evaluated the results according to the ISO guide to the expression of uncertainty in measurement, and validated the method successfully by comparison with gravimetrically produced samples of CO{sub 2} in N{sub 2}.

  8. Quadratic function between arterial partial oxygen pressure and mortality risk in sepsis patients: an interaction with simplified acute physiology score

    OpenAIRE

    Zhongheng Zhang; Xuqing Ji

    2016-01-01

    Oxygen therapy is widely used in emergency and critical care settings, while there is little evidence on its real therapeutic effect. The study aimed to explore the impact of arterial oxygen partial pressure (PaO2) on clinical outcomes in patients with sepsis. A large clinical database was employed for the study. Subjects meeting the diagnostic criteria of sepsis were eligible for the study. All measurements of PaO2 were extracted. The primary endpoint was death from any causes during hospita...

  9. Temperature measurements of partially-melted tin as a function of shock pressure

    Energy Technology Data Exchange (ETDEWEB)

    Seifter, Achim [Los Alamos National Laboratory; Furlanetto, Michael R [Los Alamos National Laboratory; Holtkamp, David B [Los Alamos National Laboratory; Obst, Andrew W [Los Alamos National Laboratory; Payton, J R [Los Alamos National Laboratory; Stone, J B [Los Alamos National Laboratory; Tabaka, L J [Los Alamos National Laboratory; Grover, M [NST; Macrum, G [NST; Stevens, G D [NST; Swift, D C [LLNL; Turley, W D [NST; Veeser, L R [NST

    2009-01-01

    Equilibrium equation of state theory predicts that the free surface release temperature of shock loaded tin will show a plateau of 505 K in the pressure range from 19.5 to 33.0 GPa, corresponding to the solid-liquid mixed-phase region. In this paper we report free surface temperature measurements on shock-loaded tin from 15 to 31 GPa using multi-wavelength optical pyrometry. The shock waves were generated by direct contact of detonating high explosive with the sample. The pressure in the sample was determined by free surface velocity measurements using Photon Doppler Velocimetry. The emitted thermal radiance was measured at four wavelength bands in the near IR region from 1.5 to 5.0 {micro}m. The samples in most of the experiments had diamond-turned surface finishes, with a few samples being polished or ball rolled. At pressures higher than 25 GPa the measured free surface temperatures were higher than the predicted 505 K and increased with increasing pressure. This deviation could be explained by hot spots and/or variations in surface emissivity and requires a further investigation.

  10. Partially implicit finite difference scheme for calculating dynamic pressure in a terrain-following coordinate non-hydrostatic ocean model

    Science.gov (United States)

    Liu, Zhe; Lin, Lei; Xie, Lian; Gao, Huiwang

    2016-10-01

    To improve the efficiency of the terrain-following σ-coordinate non-hydrostatic ocean model, a partially implicit finite difference (PIFD) scheme is proposed. By using explicit terms instead of implicit terms to discretize the parts of the vertical dynamic pressure gradient derived from the σ-coordinate transformation, the coefficient matrix of the discrete Poisson equation that the dynamic pressure satisfies can be simplified from 15 diagonals to 7 diagonals. The PIFD scheme is shown to run stably when it is applied to simulate five benchmark cases, namely, a standing wave in a basin, a surface solitary wave, a lock-exchange problem, a periodic wave over a bar and a tidally induced internal wave. Compared with the conventional fully implicit finite difference (FIFD) scheme, the PIFD scheme produces simulation results of equivalent accuracy at only 40-60% of the computational cost. The PIFD scheme demonstrates strong applicability and can be easily implemented in σ-coordinate ocean models.

  11. The Effect of Humidity and Oxygen Partial Pressure on LSM–YSZ Cathode

    DEFF Research Database (Denmark)

    Knöfel, Christina; Chen, Ming; Mogensen, Mogens Bjerg

    2011-01-01

    Two series of anode supported solid oxide fuel cells (SOFC) were prepared, one with a composite cathode layer of lanthanum strontium manganite (LSM) and yttria stabilized zirconia (YSZ) on top and the other further has a LSM current collector layer on top. The fuel cells were heat treated at 1...... of manganese concentration and strontium enrichment on the surface of the materials. Formation of monoclinic zirconia and zirconate phases was also observed. These results give a closer insight into possible degradation mechanisms of SOFC composite cathode materials in dependence of humidity and oxygen partial...

  12. Continuous blood pressure monitoring in cirrhosis. Relations to splanchnic and systemic haemodynamics

    DEFF Research Database (Denmark)

    Møller, S; Christensen, E; Henriksen, Jens Henrik Sahl

    1997-01-01

    post-sinusoidal resistance, a low plasma volume, a short central circulation time, and the presence of ascites. In contrast, a low intra-arterial blood pressure was determined by a low serum sodium, a low haemoglobin, and a high cardiac output. Diuretic treatment did not influence this model......BACKGROUND/AIMS: Low arterial blood pressure is recognised as a distinctive factor in the hyperdynamic circulation in cirrhosis. 24-hour monitoring of the blood pressure and heart rate has recently revealed a reduced circadian variation with relation to liver function. However, associations...... with cirrhosis than in matched controls (p low 24-h arterial blood pressure were a high...

  13. On the influence of the hysteretic behavior of the capillary pressure on the wave propagation in partially saturated soils

    Science.gov (United States)

    Albers, Bettina

    2016-06-01

    It is well known that the capillary pressure curve of partially saturated soils exhibits a hysteresis. For the same degree of saturation it has different values depending on the initial state of the soil, thus for drying of a wet soil or wetting of a dry soil. The influence of these different values of the capillary pressure on the propagation of sound waves is studied by use of a linear hyperbolic model. Even if the model does not contain a hysteresis operator, the effect of hysteresis in the capillary pressure curve is accounted for. In order to obtain the limits of phase speeds and attenuations for the two processes the correspondent values for main drying and main wetting are inserted into the model separately. This is done for two examples of soils, namely for Del Monte sand and for a silt loam both filled by an air-water mixture. The wave analysis reveals four waves: one transversal wave and three longitudinal waves. The waves which are driven by the immiscible pore fluids are influenced by the hysteresis in the capillary pressure curve while the waves which are mainly driven by the solid are not.

  14. On the Installation of Jet Engine Nacelles on a Wing Fourth Partial Report: Pressure-Distribution Measurements on a Sweptback Wing with Jet Engine Nacelle

    Science.gov (United States)

    Buschner, R.

    1949-01-01

    The present report, which deals with pressure-distribution measurements made on a sweptback wing with a jet engine nacelle, is similar to a report on pressure-distribution measurements on a rectangular wing with a jet engine nacelle (second partial report). Here, in investigations preliminary to high-speed measurements, as in the second partial report, useful arrangements and fillet designs have been discovered.

  15. Severe head injuries and intracranial pressure monitoring outcome in Southern Iran

    Directory of Open Access Journals (Sweden)

    Majid Reza Farrokhi

    2006-11-01

    Full Text Available BACKGROUND: Head injury is still a major cause of death and disability. Despite advances in intensive monitoring and clinical practice, little data is available to show the predictive value of intracranial pressure monitoring in assessment of the outcome of head injuries. This study was undertaken to evaluate this predictive value and is the first Iranian study in which ICP monitoring has been included. METHODS: In a prospective study from September 1999 to September 2003, all head- injured patients (53 patients with GCS of 4-8 who were admitted to Nemazee Hospital of Shiraz University of Medical Sciences were included in this study. Subarachnoid screw method or ventricular catheter via ventriculostomy was used to determine intracranial pressure. Patients were monitored for 3 days and were followed for two years at 6-month intervals. RESULTS: Car accidents were the most common cause of head injury (43.3% and 43.3% of patients had GCS of 8. Sixty percent of patients had abnormal intracranial pressure. The patients were most commonly in their first decade of life (18.8% and 81% of patients were male. Controlling increased intracranial pressure was successful in 60% of patients and resulted in a decrease of mortality rate from 60% to 15%. CONCLUSIONS: Early treatment of increased intracranial pressure in head injury patients would be beneficial in reducing mortality and morbidity rates. KEY WORDS: Southern Iran, head injury, outcome, intracranial pressure.

  16. Solar fuel processing efficiency for ceria redox cycling using alternative oxygen partial pressure reduction methods

    OpenAIRE

    Lin, Meng; Haussener, Sophia

    2015-01-01

    Solar-driven non-stoichiometric thermochemical redox cycling of ceria for the conversion of solar energy into fuels shows promise in achieving high solar-to-fuel efficiency. This efficiency is significantly affected by the operating conditions, e.g. redox temperatures, reduction and oxidation pressures, solar irradiation concentration, or heat recovery effectiveness. We present a thermodynamic analysis of five redox cycle designs to investigate the effects of working conditions on the fuel pr...

  17. Surface tension and its temperature coefficient of molten tin determined with the sessile drop method at different oxygen partial pressures.

    Science.gov (United States)

    Yuan, Zhang Fu; Mukai, Kusuhiro; Takagi, Katsuhiko; Ohtaka, Masahiko; Huang, Wen Lai; Liu, Qiu Sheng

    2002-10-15

    The surface tension of molten tin has been determined by the sessile drop method at temperatures ranging from 523 to 1033 K and in the oxygen partial pressure (P(O(2))) range from 2.85 x 10(-19) to 8.56 x 10(-6) MPa, and its dependence on temperature and oxygen partial pressure has been analyzed. At P(O(2))=2.85 x 10(-19) and 1.06 x 10(-15) MPa, the surface tension decreases linearly with the increase of temperature and its temperature coefficients are -0.151 and -0.094 mN m(-1) K(-1), respectively. However, at high P(O(2)) (3.17 x 10(-10), 8.56 x 10(-6) MPa), the surface tension increases with the temperature near the melting point (505 K) and decreases above 723 K. The surface tension decrease with increasing P(O(2)) is much larger near the melting point than at temperatures above 823 K. The contact angle between the molten tin and the alumina substrate is 158-173 degrees, and the wettability is poor.

  18. Effects of oxygen partial pressure and annealing on dispersive optical nonlinearity in NiO thin films

    Science.gov (United States)

    Chouhan, Romita; Baraskar, Priyanka; Agrawal, Arpana; Gupta, Mukul; Sen, Pranay K.; Sen, Pratima

    2017-07-01

    We report annealing induced sign reversal of dispersive optical nonlinearity in ion beam sputtered NiO thin films deposited at 30% and 70% oxygen partial pressures. In the Ultraviolet-visible spectra of the samples, the transmission peak corresponding to d-d transitions is observed near 2 eV. A shift in this peak towards higher energy was observed when the same films were annealed at 523 K. The near resonant photoinduced transitions produced giant nonlinear optical susceptibilities of both third- and fifth- orders when the annealed film was irradiated by a continuous wave 632.8 nm He-Ne laser. The role of the thermo-optic effect has been examined critically. Experimental studies further reveal that the oxygen partial pressure influences the growth direction of the grains in the thin films. The well known Z-scan experimental procedure has been followed for measurements of optical nonlinearities in all the NiO films. The nonlinear refractive indices of both the as-deposited and annealed NiO thin films are defined in terms of the thermo-optic coefficients (d/nd T ) T =T0 and (d/2nd T2 ) T =T0 .

  19. Distribution of the CO{sub 2} partial pressure in the Atlantic ocean between Iceland and the Antarctic peninsula

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Institute for Baltic Sea Research, Rostock-Warnemuende (Germany); Morlang, J. [Institute for Marine Research, Kiel (Germany)

    1995-02-01

    CO{sub 2} partial pressure of surface water, (pCO{sub 2}){sub sw}, was measured continuously during two cruises in the Atlantic Ocean in November/December 1991 and May 1992. A (pCO{sub 2}){sub sw} profile between Iceland and the Antarctic Peninsula is obtained which demonstrates that along the investigated transect the Atlantic Ocean is largely a potential sink for atmospheric CO{sub 2}, especially at high latitudes, where partial pressure differences of -80{mu}atm to -100 {mu}atm are observed. A significant potential source region exists only between the equator and 10 degrees S with a maximum {Delta}pCO{sub 2} of 35 {mu}atm. An attempt is made to identify the processes that control the (pCO{sub 2}){sub sw} distribution pattern. The investigations at latitudes >40 degrees in both hemispheres were performed during spring and correlations between (pCO{sub 2}){sub sw} and chlorophyll a contents indicate that biological production mainly controls the distribution of (pCO{sub 2}){sub sw}. At lower latitudes, (pCO{sub 2}){sub sw} is mainly related to temperature and salinity, but also an upwelling effect could be identified close to the equator. 24 refs, 11 figs

  20. Effect of oxygen partial pressure on oxidation performance of iron-aluminide layers on 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hong-guang; Zhan, Qin; Zhao, Wei-wei; Yuan, Xiao-ming [China Institute of Atomic Energy, Beijing (China). Dept. of Reactor Engineering Research and Design

    2009-07-01

    Tritium permeation barriers (TPB) are required in fusion technology in order to reduce the tritium permeation rate through the structural materials such as type 316 stainless steel. Iron-aluminide layers with alumina on top have been selected as the reference materials for TPB. Aluminide were prepared on the 316L (00Cr17Ni14Mo2) stainless steel by a specific aluminizing process and its oxidation behaviors have been studied in CIAE. This paper is focused on the effect of oxygen partial pressure on the characterization of the surface alumina films. Alumina films were formed on the Fe-Al coatings under the oxygen partial pressure below 200Pa, which is mainly composed of Al{sub 2}O{sub 3} with the thickness upto 300nm, and a little CeO{sub 2} and Cr{sub 2}O{sub 3}. It shows the formation of alumina films because of the selective oxidation of the aluminide on the top surface. (orig.)

  1. Intracerebral abscess associated with the Camino intracranial pressure monitor: case report and review of the literature.

    Science.gov (United States)

    Morton, Ryan; Lucas, Timothy H; Ko, Andrew; Browd, Samuel R; Ellenbogen, Richard G; Chesnut, R M

    2012-07-01

    Intracranial pressure (ICP) monitoring is a mainstay in the management of traumatic brain injury. Large investigations have validated the safety and efficacy of ICP monitors in comatose patients. Clinically relevant infections are extremely rare and cerebral abscess has never been reported with the Camino device. We describe an exceptional case of a life-threatening intracerebral abscess from an intraparenchymal ICP monitor. A 35-month-old child required 7 days of ICP monitoring after a fall from a 2-story window. His hospital course was complicated by severe airway edema treated, in part, with high-dose corticosteroid therapy for a total of 10 days. Two weeks later, the patient deteriorated acutely owing to a large intracerebral abscess under the previous ICP monitor site. Urgent craniotomy with evacuation of the abscess was performed on 2 separate occasions. Cultures grew methicillin-sensitive Staphylococcus aureus, which was treated with long-term antibiotics. At the 3-month follow-up, the patient was meeting age-appropriate milestones without focal deficits. To the best of our knowledge, this is the first report describing an intracerebral abscess as a complication from an intraparenchymal pressure monitor. Corticosteroid therapy may have constituted an independent risk factor for the ICP monitor--associated infection, as well as reinsertion of the ICP monitoring device at the same site. That this is the first reported parenchymal infectious complication underscores the safety of this device with respect to infection. When reinsertion of a parenchymal monitor is considered, a new site should be chosen.

  2. Arterial pressure changes monitoring with a new precordial noninvasive sensor

    Directory of Open Access Journals (Sweden)

    Faita Francesco

    2008-08-01

    Full Text Available Abstract Background Recently, a cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been validated. A further application is the assessment of Second Heart Sound (S2 amplitude variations at increasing heart rates. The aim of this study was to assess the relationship between second heart sound amplitude variations at increasing heart rates and hemodynamic changes. Methods The transcutaneous force sensor was positioned in the precordial region in 146 consecutive patients referred for exercise (n = 99, dipyridamole (n = 41, or pacing stress (n = 6. The curve of S2 peak amplitude variation as a function of heart rate was computed as the increment with respect to the resting value. Results A consistent S2 signal was obtained in all patients. Baseline S2 was 7.2 ± 3.3 mg, increasing to 12.7 ± 7.7 mg at peak stress. S2 percentage increase was + 133 ± 104% in the 99 exercise, + 2 ± 22% in the 41 dipyridamole, and + 31 ± 27% in the 6 pacing patients (p Conclusion S2 recording quantitatively documents systemic pressure changes.

  3. Effect of prosthetic design on center of pressure excursion in partial foot prostheses

    Directory of Open Access Journals (Sweden)

    Michael P. Dillon, PhD, BPO(Hons

    2011-02-01

    Full Text Available Investigations into the gait of persons with partial foot amputation (PFA suggest that the effective foot length can be restored when the prosthesis incorporates a relatively stiff forefoot, restricts dorsiflexion, and includes a mechanism whereby forces caused by loading the toe lever can be comfortably distributed to the leg (e.g., an anterior tibial shell. The purpose of this investigation was to systematically alter these variables to understand which design elements are responsible for restoration of the effective foot length. By manipulating features of the prosthesis design in two persons with PFA, we demonstrated using three-dimensional motion analysis that the prosthesis must incorporate each of these design elements to restore the effective foot length. When these design elements were used in concert, the persons with PFA adopted a gait pattern more consistent with nondisabled persons. Further work is required on a larger cohort to ensure the observations are generalizable.

  4. Effects of inner materials on the sensitivity and phase depth of wireless inductive pressure sensors for monitoring intraocular pressure

    Science.gov (United States)

    Jang, Cheol-In; Shin, Kyeong-Sik; Kim, Mi Jeung; Yun, Kwang-Seok; Park, Ki Ho; Kang, Ji Yoon; Lee, Soo Hyun

    2016-03-01

    In this research, we developed wireless, inductive, pressure sensors with high sensitivity and investigated the effects of the inner materials (copper or ferrite) on the performance of the sensors. The proposed sensor is comprised of two parts, i.e., the top and the bottom parts. The top part includes a micro coil and a capacitor for the wireless transfer of data, and the bottom part includes the inner materials and a thick or thin flexible membrane to induce changes in the inductance. An anchor is used to assemble the top and bottom parts. The behavior of the sensor with copper was based on the eddy current effect, and, as the pressure increased, its resonance frequency increased, while its phase depth decreased exponentially. The principle of the sensor with ferrite was related to the effective permeability between a ferrite and a coil, and its response was the opposite of that with copper, i.e., as the pressure increased, the resonance frequency decreased linearly, and the phase depth increased linearly. These different operational mechanisms can be explained by the changes in the equations of inductance presented in this paper. After characterizing four different types of inductive pressure sensors in ambient air, one type of inductive pressure sensor was used to monitor the intraocular pressure (IOP) of a rabbit's eye as a biomedical application. The results showed that, in the animal tests, the measured responsivity and sensitivity were 16.7 kHz/mmHg and 1340 ppm/mmHg, respectively. These data indicate that the proposed sensor is a good candidate for monitoring IOP.

  5. Monitoring of low pressure plasma systems; Ueberwachung von Niederdruck-Plasmaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Michaeli, W.; Hegenbart, A.; Binkowski, D.; Fragstein, F. v. [Inst. fuer Kunststoffverarbeitung (IKV) an der RWTH Aachen (Germany)

    2007-02-15

    The optical emission spectroscopy (OES) is a very flexible and easy to use method to monitor industrial plasma processes. By directly monitoring the plasma itself many additional factors influencing low pressure plasma processes can be observed. First of all factors that can not be controlled directly play an important role in this context. Examples are contaminations and leaks in the plasma system. These can negatively influence the reproducibility of production processes. In this paper the effect of a leak on the coating and the plasma process is being shown. Additionally the detection of contaminations and sealing problems in a microwave plasma source is being demonstrated. By using the correlations being presented the OES can be used to continually monitor low pressure plasma systems and thus enhance reproducibility of industrial low pressure plasma processes. (orig.)

  6. Pressure monitoring inside Meckel's cave during percutaneous microcompression of gasserian ganglion.

    Science.gov (United States)

    Zanusso, M; Curri, D; Landi, A; Colombo, F; Volpin, L; Cervellini, P

    1991-01-01

    During percutaneous microcompression of the gasserian ganglion for the relief of trigeminal neuralgia, a computerized technique for monitoring the pressure inside Meckel's cave was employed in 22 patients. A dedicated transducer connected to a computer records the balloon inflation pressure. Its variations are discernible within tenths of a bar and are plotted in relation to time. The intraoperative pressure inside Meckel's cave is from 0.9 to 2.4 bars. When pressure was low, there was recurrence of pain. The highest values of pressure (1.9-2.4 bars) were observed in most of the patients suffering from untoward side effects. The clinical results seem to be influenced by the level of the intraoperative intracavitary pressure.

  7. The estimated sensitivity and specificity of compartment pressure monitoring for acute compartment syndrome.

    Science.gov (United States)

    McQueen, Margaret M; Duckworth, Andrew D; Aitken, Stuart A; Court-Brown, Charles M

    2013-04-17

    The aim of our study was to document the estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome. From our prospective trauma database, we identified all patients who had sustained a tibial diaphyseal fracture over a ten-year period. A retrospective analysis of 1184 patients was performed to record and analyze the documented use of continuous intracompartmental pressure monitoring and the use of fasciotomy. A diagnosis of acute compartment syndrome was made if there was escape of muscles at fasciotomy and/or color change in the muscles or muscle necrosis intraoperatively. A diagnosis of acute compartment syndrome was considered incorrect if it was possible to close the fasciotomy wounds primarily at forty-eight hours. The absence of acute compartment syndrome was confirmed by the absence of neurological abnormality or contracture at the time of the latest follow-up. Of 979 monitored patients identified, 850 fit the inclusion criteria with a mean age of thirty-eight years (range, twelve to ninety-four years), and 598 (70.4%) were male (p compartment syndrome: 141 had acute compartment syndrome (true positives), six did not have it (false positives), and five underwent fasciotomy despite having a normal differential pressure reading, with subsequent operative findings consistent with acute compartment syndrome (false negatives). Of the 698 patients (82.1%) who did not undergo fasciotomy, 689 had no evidence of any late sequelae of acute compartment syndrome (true negatives) at a mean follow-up time of fifty-nine weeks. The estimated sensitivity of intracompartmental pressure monitoring for suspected acute compartment syndrome was 94%, with an estimated specificity of 98%, an estimated positive predictive value of 93%, and an estimated negative predictive value of 99%. The estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of

  8. Novel Approach for Ensuring Increased Validity in Home Blood Pressure Monitoring

    DEFF Research Database (Denmark)

    Wagner, Stefan Rahr; Toftegaard, Thomas Skjødeberg; Bertelsen, Olav Wedege

    This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure but with the devi......This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure...... but with the devices currently available it cannot be verified whether a user is actually following the recommendations or not. An initial prototype is presented implementing part of the proposed solution including a limited pilot study as a status on the work in progress. Results indicate that the solution...

  9. Carotid arterial blood pressure waveform monitoring using a portable ultrasound system.

    Science.gov (United States)

    Joohyun Seo; Pietrangelo, Sabino J; Hae-Seung Lee; Sodini, Charles G

    2015-08-01

    This work presents a non-invasive arterial blood pressure (ABP) waveform monitoring technique using ultrasound. A portable ultrasound system to excite ultrasound transducers and acquire data is designed with off-the-shelf components. The insonation angles are identified using a vector Doppler technique based on the cosine dependency of the Doppler signals. The pulse pressure of an estimated waveform at the left common carotid artery is compared to the standard sphygmomanometer measurement in a clinical test. The estimated carotid ABP waveform shows excellent agreement to the finger ABP waveform with expected discrepancy of the systolic peak shape due to different measurement sites. The proposed method also tracks slow blood pressure fluctuations. This validation on human subjects shows potential for a noninvasive blood pressure waveform monitoring device at central arterial sites.

  10. Development of a Calibration and Monitoring System for GD-1 High Pressure Common Rail Diesel Engine

    Institute of Scientific and Technical Information of China (English)

    王俊席; 杨林; 冯静; 冒晓建; 卓斌

    2004-01-01

    Based on CAN calibration protocol, a new calibration and monitoring system was developed for the GD1 high pressure common rail diesel engine. CAN driver block, monitoring program and calibration program for this system were designed respectively. The inquiry mode was used in the monitoring program and the interrupt mode was used in calibration program. The calibration program was designed in structural programming model. This system provides a reliable, accurate and quick CAN bus between ECU and PC, with baud rate up to 500Kbit/s.The implementation of the compatible and universal CAN calibration protocol makes it easy to displace the system and its function modules. It also provides friendly, compatible and flexible calibration interface, and the functions of online calibration and real-time monitoring. This system was successfully used in a GD-1 high pressure common rail diesel engine and the engine performance and exhaust emissions were significantly improved.

  11. THE EFFECTS OF PULSE BIAS VOLTAGE AND N2 PARTIAL PRESSURE ON TiAIN FILMS OF ARC ION PLATING (AIP)

    Institute of Scientific and Technical Information of China (English)

    M.S. Li; S.L. Zhu; Fuhui Wang; C. Sun; L.S. Wen

    2001-01-01

    Owing to the characteristics of arc ion plating(AIP) technique, the structure and com-position of TiAlN films can be tailored by controlling of various parameters such ascompositions of target materials, N2 partial pressure, substrate bias and so on. ln thisstudy, several titanium aluminum nitride films were deposited on 1Cr11Ni2 W2Mo Vsteel for compressor blade of areo-engine under different d.c pulse bias voltage and ni-trogen partial pressure. The effects of substrate pulse bias and nitrogen partial pressureon the deposition rate, droplet formation, microstruture and elemental component ofthe films were investigated.

  12. [Realization of a compact mobile phone based wireless plantar pressure monitoring system and application].

    Science.gov (United States)

    Liu, Lin; Liu, Jing

    2012-05-01

    An improved compact mobile phone based wireless plantar pressure monitoring system and software are proposed based on former progress, which can collect pressure data by sensors and circuit board, transmit data through Bluetooth wirelessly, and display and calculate the data on the mobile terminal. Conceptual experiments carried out demonstrate the feasibility and accuracy of the new system The system is expected to be widely used in the future owing to its portability, ease of use, and cost-effectiveness

  13. An Improved Flexible Telemetry System to Autonomously Monitor Sub-Bandage Pressure and Wound Moisture

    OpenAIRE

    Nasir Mehmood; Alex Hariz; Sue Templeton; Voelcker, Nicolas H.

    2014-01-01

    This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data ...

  14. Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects

    OpenAIRE

    Wu J.; He W; Chen W; Zhu L

    2013-01-01

    Jun Wu1, Wei He2, Wei-min Chen1, Lian Zhu21Key Laboratory of Optoelectronic Technology and Systems, 2State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, People’s Republic of ChinaAbstract: The real-time monitoring of intracranial pressure (ICP) is very important for craniocerebrally critically ill patients, but it is very difficult to realize long-time monitoring for the traditional invasive method, which very...

  15. Radiation pressure on a submerged absorptive partial reflector deduced from the Doppler shift

    CERN Document Server

    Mansuripur, Masud

    2012-01-01

    When a light pulse is reflected from a mirror, energy and momentum are exchanged between the electromagnetic field and the material medium. The resulting change in the energy of the reflected photons is directly related to their Doppler shift arising from the change in the state of motion of the mirror. Similarly, the Doppler shift of photons that enter an absorber is intimately tied to the kinetic energy and momentum acquired by the absorber in its interaction with the incident light. The argument from the Doppler shift yields expressions for the exchanged energy and momentum that are identical with those obtained from Maxwell's equations and the Lorentz law of force, despite the fact that the physical bases of the two methods are fundamentally different. Here we apply the Doppler shift argument to a submerged partial reflector (one that absorbs a fraction of the incident light), deducing in the process the magnitude of the photon momentum within the submerging medium. We also discuss the case of the submerg...

  16. Partial Gene Deletions of PMP22 Causing Hereditary Neuropathy with Liability to Pressure Palsies

    Directory of Open Access Journals (Sweden)

    Sun-Mi Cho

    2014-01-01

    Full Text Available Hereditary neuropathy with liability to pressure palsies (HNPP is an autosomal neuropathy that is commonly caused by a reciprocal 1.5 Mb deletion on chromosome 17p11.2, at the site of the peripheral myelin protein 22 (PMP22 gene. Other patients with similar phenotypes have been shown to harbor point mutations or small deletions, although there is some clinical variation across these patients. In this report, we describe a case of HNPP with copy number changes in exon or promoter regions of PMP22. Multiplex ligation-dependent probe analysis revealed an exon 1b deletion in the patient, who had been diagnosed with HNPP in the first decade of life using molecular analysis.

  17. Ambulatory blood pressure monitoring of patients with heart failure: a new prognosis marker

    Directory of Open Access Journals (Sweden)

    Manoel F. Canesin

    2002-01-01

    Full Text Available OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3% and diastolic diameter (72.2±7.8mm were not correlated with the survival. The mean 24-hour (SBP24, waking (SBPw, and sleeping (SBPs systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively. Patients with diastolic blood pressure sleep decrements (dip and patients with mean blood pressure dip or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.

  18. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    Science.gov (United States)

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  19. [Mobile phone platform for wireless monitoring of human dynamic plantar pressure].

    Science.gov (United States)

    Wang, Hao; Han, Meng; Liu, Jing

    2010-11-01

    This paper constructed a plantar pressure sensing system based on Bluetooth communication of mobile phone with embedded Windows Mobile system. With the MCU (Microprocessor Control Unit) and Bluetooth module, the pressure sensor and the data acquisition circuit was designed and integrated, with software developed under Visual Studio 2008 environment. The real-time monitoring of human dynamic plantar pressure signal, and transferring, displaying and storing the recorded data on a mobile phone were achieved. This method offers an important measure to acquire human gait information via a pervasive and low cost way.

  20. Interplay of the influence of oxygen partial pressure and rf power on the properties of rf-magnetron-sputtered AZO thin films

    Indian Academy of Sciences (India)

    A KASSIS; M SAAD; F NOUNOU

    2017-08-01

    The complex interplay between the influence of oxygen partial pressure and that of rf power on the structural,electrical and optical properties of rf-magnetron-sputtered aluminium-doped zinc oxide, AZO, thin films is illustrated. Thedependence of film electrical resistance and interplanar spacing of film crystallites on rf power seems to be different athigher oxygen partial pressure values than at lower ones. Film preparation was performed at room temperature (withoutextra heating) and low pressure $p = 0.5$ mTorr, varying the rf power density between $P = 0.57$ and 2.83 W cm$^{−2}$ at different relative oxygen partial pressure values. An explanation of film properties has been sought in terms of changes in the chemical properties of the films due to the bombardment of the films during film formation with negative oxygen ions.

  1. Oxidation behavior of V-Cr-Ti alloys in low-partial-pressure oxygen environments

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.; Uz, M. [Argonne National Lab., IL (United States)

    1998-09-01

    A test program is in progress at Argonne National Laboratory to evaluate the effect of pO{sub 2} in the exposure environment on oxygen uptake, scaling kinetics, and scale microstructure in V-Cr-Ti alloys. The data indicate that the oxidation process follows parabolic kinetics in all of the environments used in the present study. From the weight change data, parabolic rate constants were evaluated as a function of temperature and exposure environment. The temperature dependence of the parabolic rate constants was described by an Arrhenius relationship. Activation energy for the oxidation process was fairly constant in the oxygen pressure range of 1 {times} 10{sup {minus}6} to 1 {times} 10{sup {minus}1} torr for both the alloys. The activation energy for oxidation in air was significantly lower than in low-pO{sub 2} environments, and for oxidation in pure O{sub 2} at 760 torr was much lower than in low-pO{sub 2} environments. X-ray diffraction analysis of the specimens showed that VO{sub 2} was the dominant phase in low-pO{sub 2} environments, while V{sub 2}O{sub 5} was dominant in air and in pure oxygen at 76f0 torr.

  2. Ceramic MEMS Designed for Wireless Pressure Monitoring in the Industrial Environment

    Directory of Open Access Journals (Sweden)

    Marko Pavlin

    2011-12-01

    Full Text Available This paper presents the design of a wireless pressure-monitoring system for harsh-environment applications. Two types of ceramic pressure sensors made with a low-temperature cofired ceramic (LTCC were considered. The first type is a piezoresistive strain gauge pressure sensor. The second type is a capacitive pressure sensor, which is based on changes of the capacitance values between two electrodes: one electrode is fixed and the other is movable under an applied pressure. The design was primarily focused on low power consumption. Reliable operation in the presence of disturbances, like electromagnetic interference, parasitic capacitances, etc., proved to be contradictory constraints. A piezoresistive ceramic pressure sensor with a high bridge impedance was chosen for use in a wireless pressure-monitoring system and an acceptable solution using energy-harvesting techniques has been achieved. The described solution allows for the integration of a sensor element with an energy harvester that has a printed thick-film battery and complete electronics in a single substrate packaged inside a compact housing.

  3. Variations in alveolar partial pressure for carbon dioxide and oxygen have additive not synergistic acute effects on human pulmonary vasoconstriction.

    Directory of Open Access Journals (Sweden)

    Quentin P P Croft

    Full Text Available The human pulmonary vasculature constricts in response to hypercapnia and hypoxia, with important consequences for homeostasis and adaptation. One function of these responses is to direct blood flow away from poorly-ventilated regions of the lung. In humans it is not known whether the stimuli of hypercapnia and hypoxia constrict the pulmonary blood vessels independently of each other or whether they act synergistically, such that the combination of hypercapnia and hypoxia is more effective than the sum of the responses to each stimulus on its own. We independently controlled the alveolar partial pressures of carbon dioxide (Paco 2 and oxygen (Pao 2 to examine their possible interaction on human pulmonary vasoconstriction. Nine volunteers each experienced sixteen possible combinations of four levels of Paco 2 (+6, +1, -4 and -9 mmHg, relative to baseline with four levels of Pao 2 (175, 100, 75 and 50 mmHg. During each of these sixteen protocols Doppler echocardiography was used to evaluate cardiac output and systolic tricuspid pressure gradient, an index of pulmonary vasoconstriction. The degree of constriction varied linearly with both Paco 2 and the calculated haemoglobin oxygen desaturation (1-So2. Mixed effects modelling delivered coefficients defining the interdependence of cardiac output, systolic tricuspid pressure gradient, ventilation, Paco 2 and So2. No interaction was observed in the effects on pulmonary vasoconstriction of carbon dioxide and oxygen (p>0.64. Direct effects of the alveolar gases on systolic tricuspid pressure gradient greatly exceeded indirect effects arising from concurrent changes in cardiac output.

  4. Fluid responsiveness predicted by transcutaneous partial pressure of oxygen in patients with circulatory failure: a prospective study.

    Science.gov (United States)

    Xu, Jingyuan; Peng, Xiao; Pan, Chun; Cai, Shixia; Zhang, Xiwen; Xue, Ming; Yang, Yi; Qiu, Haibo

    2017-12-01

    Significant effort has been devoted to defining parameters for predicting fluid responsiveness. Our goal was to study the feasibility of predicting fluid responsiveness by transcutaneous partial pressure of oxygen (PtcO2) in the critically ill patients. This was a single-center prospective study conducted in the intensive care unit of a tertiary care teaching hospital. Shock patients who presented with at least one clinical sign of inadequate tissue perfusion, defined as systolic blood pressure 40 mmHg in previously hypertensive patients or the need for vasopressive drugs; urine output 4 mmol/l, for less than 24 h in the absence of a contraindication for fluids were eligible to participate in the study. PtcO2 was continuously recorded before and during a passive leg raising (PLR) test, and then before and after a 250 ml rapid saline infusion in 10 min. Fluid responsiveness is defined as a change in the stroke volume ≥10% after 250 ml of volume infusion. Thirty-four patients were included, and 14 responded to volume expansion. In the responders, the mean arterial pressure, central venous pressure, cardiac output, stroke volume and PtcO2 increased significantly, while the heart rate decreased significantly by both PLR and volume expansion. Changes in the stroke volume induced either by PLR or volume expansion were significantly greater in responders than in non-responders. The correlation between the changes in PtcO2 and stroke volume induced by volume expansion was significant. Volume expansion induced an increase in the PtcO2 of 14% and PLR induced an increase in PtcO2 of 13% predicted fluid responsiveness. This study suggested the changes in PtcO2 induced by volume expansion and a PLR test predicted fluid responsiveness in critically ill patients. Trial registration NCT02083757.

  5. Summary of Activities for Health Monitoring of Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Russell, Rick; Skow, Miles

    2013-01-01

    This three-year project (FY12-14) will design and demonstrate the ability of new Magnetic Stress Gages for the measurement of stresses on the inner diameter of a Composite Overwrapped Pressure Vessel overwrap. The sensors are being tested at White Sands Testing Facility (WSTF) where the results will be correlated with a known nondestructive technique acoustic emission. The gages will be produced utilizing Meandering Winding Magnetometer (MWM) and/or MWM array eddy current technology. The ultimate goal is to utilize this technology for the health monitoring of Composite Overwrapped Pressure Vessels for all future flight programs. The first full-scale pressurization test was performed at WSTF in June 2012. The goals of this test were to determine adaptations of the magnetic stress gauge instrumentation that would be necessary to allow multiple sensors to monitor the vessel's condition simultaneously and to determine how the sensor response changes with sensor selection and orientation. The second full scale pressurization test was performed at WSTF in August 2012. The goals of this test were to monitor the vessel's condition with multiple sensors simultaneously, to determine the viability of the multiplexing units (MUX) for the application, and to determine if the sensor responses in different orientations are repeatable. For both sets of tests the vessel was pressured up to 6,000 psi to simulate maximum operating pressure. Acoustic events were observed during the first pressurization cycle. This suggested that the extended storage period prior to use of this bottle led to a relaxation of the residual stresses imparted during auto-frettage. The pressurization tests successfully demonstrated the use of multiplexers with multiple MWM arrays to monitor a vessel. It was discovered that depending upon the sensor orientation, the frequencies, and the sense element, the MWM arrays can provide a variety of complementary information about the composite overwrapped pressure

  6. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  7. Continuous blood pressure monitoring in cirrhosis. Relations to splanchnic and systemic haemodynamics

    DEFF Research Database (Denmark)

    Møller, Søren; Christensen, E; Henriksen, Jens Henrik

    1997-01-01

    with cirrhosis than in matched controls (p blood pressures and heart rate, pertinent variables were included in a multivariate regression model. This model revealed that independent determinants of a low 24-h arterial blood pressure were a high...... post-sinusoidal resistance, a low plasma volume, a short central circulation time, and the presence of ascites. In contrast, a low intra-arterial blood pressure was determined by a low serum sodium, a low haemoglobin, and a high cardiac output. Diuretic treatment did not influence this model......BACKGROUND/AIMS: Low arterial blood pressure is recognised as a distinctive factor in the hyperdynamic circulation in cirrhosis. 24-hour monitoring of the blood pressure and heart rate has recently revealed a reduced circadian variation with relation to liver function. However, associations...

  8. Agreement Between Doppler and Invasive Blood Pressure Monitoring in Anesthetized Dogs Weighing <5 kg.

    Science.gov (United States)

    Kennedy, Martin J; Barletta, Michele

    2015-01-01

    The objectives of this study were to determine if Doppler (DOP) blood pressure measurements more closely estimate either invasive systolic or invasive mean arterial blood pressures (ISAP or IMAP, respectively) in small dogs under general anesthesia and to assess the ability of DOP to detect anesthesia-related hypotension in small dogs. Blood pressure measurements (n = 203) were obtained from 10 client-owned dogs. DOP, ISAP, and IMAP were recorded simultaneously, and the data were categorized into two groups: hypotensive (ISAP dogs, suggesting that DOP measures systolic arterial blood pressure in dogs dogs with hypotension, DOP met all of the performance criteria for noninvasive blood pressure monitors recommended by the American College of Veterinary Internal Medicine. DOP is an acceptably accurate and highly specific means of detecting hypotension in small dogs under general anesthesia.

  9. Aldehydes in hydrothermal solution - Standard partial molal thermodynamic properties and relative stabilities at high temperatures and pressures

    Science.gov (United States)

    Schulte, Mitchell D.; Shock, Everett L.

    1993-01-01

    Aldehydes are common in a variety of geologic environments and are derived from a number of sources, both natural and anthropogenic. Experimental data for aqueous aldehydes were taken from the literature and used, along with parameters for the revised Helgeson-Kirkham-Flowers (HKF) equations of state, to estimate standard partial molal thermodynamic data for aqueous straight-chain alkyl aldehydes at high temperatures and pressures. Examples of calculations involving aldehydes in geological environments are given, and the stability of aldehydes relative to carboxylic acids is evaluated. These calculations indicate that aldehydes may be intermediates in the formation of carboxylic acids from hydrocarbons in sedimentary basin brines and hydrothermal systems like they are in the atmosphere. The data and parameters summarized here allow evaluation of the role of aldehydes in the formation of prebiotic precursors, such as amino acids and hydroxy acids on the early Earth and in carbonaceous chondrite parent bodies.

  10. Effects of oxygen partial pressure on optical properties of NiOX films deposited by reactive DC-magnetron sputtering

    Institute of Scientific and Technical Information of China (English)

    Ying Zhou; Yongyou Geng; Donghong Gu

    2006-01-01

    The influence of oxygen partial pressure on the optical properties of NiOX thin films deposited by reactive DC-magnetron sputtering from a nickel metal target in a mixture gas of oxygen and argon was presented.With the oxygen ratio increasing, the reflectivity of the as-deposited films decreased, and optical band gap increased. Thermogravimetric analysis (TGA) showed that the decompose temperature of the films was above 250 ℃. After annealed at 400 ℃, only films deposited at 5% O2/Ar ratio showed high opticalcontrast which was about 52%. Scanning electron microscope (SEM) results revealed that the changes ofsurface morphology were responsible for the optical property variations of the films after annealing. Itsthermal stability and high optical contrast before and after annealing made it a good potential write-onceoptical recording medium.

  11. Growth of GaAs from a free surface melt under controlled arsenic pressure in a partially confined configuration

    Science.gov (United States)

    Gatos, H. C.; Lagowski, J.; Wu, Y.

    1988-01-01

    A partially confined configuration for the growth of GaAs from melt in space was developed, consisting of a triangular prism containing the seed crystal and source material in the form of a rod. It is suggested that the configuration overcomes two obstacles in the growth of GaAs in space: total confinement in a quartz crucible and lack of arsenic pressure control. Ground tests of the configuration show that it is capable of crystal growth in space and is useful for studying the growth of GaAs from a free-surface melt on earth. The resulting chemical composition, electrical property variations, and phenomenological models to account for the results are presented.

  12. Equilibrium polarization of ultrathin PbTiO{<_3} with surface compensation controlled by oxygen partial pressure.

    Energy Technology Data Exchange (ETDEWEB)

    Highland, M. J.; Fister, T. T.; Fong, D. D.; Fuoss, P. H.; Thompson, C.; Eastman, J. A.; Streiffer, S. K.; Stephenson, G. B. (Chemical Sciences and Engineering Division); ( MSD); ( OTD-PSE); (Northern Illinois Univ.)

    2011-01-01

    We present a synchrotron x-ray study of the equilibrium polarization structure of ultrathin PbTiO{sub 3} films on SrRuO{sub 3} electrodes epitaxially grown on SrTiO{sub 3} (001) substrates, as a function of temperature and the external oxygen partial pressure (pO{sub 2}) controlling their surface charge compensation. We find that the ferroelectric Curie temperature (T{sub c}) varies with pO{sub 2} and has a minimum at the intermediate pO{sub 2}, where the polarization below T{sub c} changes sign. The experiments are in qualitative agreement with a model based on Landau theory that takes into account the interaction of the phase transition with the electrochemical equilibria for charged surface species. The paraelectric phase is stabilized at intermediate pO2 when the concentrations of surface species are insufficient to compensate either polar orientation.

  13. Utility of the theory of planned behavior to predict nursing staff blood pressure monitoring behaviours.

    Science.gov (United States)

    Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C

    2014-02-01

    To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing

  14. Validation of a two-axis accelerometer for monitoring patient activity during blood pressure or ECG holter monitoring.

    Science.gov (United States)

    Wetzler, Marie-Laure; Borderies, Jean René; Bigaignon, Odile; Guillo, Pascal; Gosse, Philippe

    2003-12-01

    The aim of the study was to evaluate the efficiency of a position/activity monitoring system based on a dual-axis accelerometer strapped to the subject's thigh and a position sensor located within a monitor placed on the subject's belt. Twenty-six subjects wearing two monitors (one accelerometer on each thigh) were submitted to various activities and positions under the control of an observer. An analysis of each tracing was performed both manually by a technician and automatically by dedicated software before being compared with the information gathered during the study. The accelerometer allowed accurate discrimination between the standing versus the sitting and lying positions. The sitting and lying positions were correctly detected by the built-in position sensor provided the unit was firmly attached. Walking was adequately detected by the accelerometer. The activity score was well correlated with treadmill speed. Changes in position and activity were detected with a mean error of less than 3 s. The combination of an accelerometer placed on the subject's thigh and a position sensor located at the subject's waist appeared to be a suitable system for position/activity monitoring during ambulatory ECG and blood pressure monitoring.

  15. X-ray Photoelectron Spectroscopy Study of Indium Tin Oxide Films Deposited at Various Oxygen Partial Pressures

    Science.gov (United States)

    Peng, Shou; Cao, Xin; Pan, Jingong; Wang, Xinwei; Tan, Xuehai; Delahoy, Alan E.; Chin, Ken K.

    2017-02-01

    Here, a systematic experimental study on indium tin oxide (ITO) films is presented to investigate the effects of oxygen partial pressure on the film's electrical properties. The results of Hall measurements show that adding more oxygen in the sputtering gas has negative influences on the electrical conductivity of ITO films. As O2/(O2 + Ar)% in the sputtering gas is increased from 0 to 6.98%, the resistivity of ITO film rises almost exponentially from 7.9 × 10-4 to 4.1 × 10-2 Ω cm, with the carrier density decreasing from 4.8 × 1020 to 5.4 × 1018 cm-3. The origins of these negative effects are discussed with focuses on the concentration of ionized impurities and the scattering of grain barriers. Extensive x-ray photoelectron spectroscopy (XPS) analyses were employed to gain insight into the concentration of ionized impurities, demonstrating a strong correlation between the oxygen vacancy concentration and the carrier density in ITO films as a function of sputtering O2 partial pressure. Other microstructural characterization techniques including x-ray diffraction (XRD), high-magnification scanning electron microscopy (SEM) and scanning transmission electron microscopy (STEM) analyses were used to evaluate the average grain size of ITO films. For ITO films that have carrier density above 1019 cm-3, scattering on grain boundaries and other crystallographic defects show negligible effects on the carrier transport. The results point to the oxygen vacancy concentration that dictates the carrier density and, thus, the resistivity of magnetron-sputtered ITO films.

  16. Clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring.

    Science.gov (United States)

    Kansui, Yasuo; Matsumura, Kiyoshi; Kida, Haruko; Sakata, Satoko; Ohtsubo, Toshio; Ibaraki, Ai; Kitazono, Takanari

    2014-01-01

    Strict control of blood pressure is important to prevent cardiovascular disease, although it is sometimes difficult to decrease blood pressure to target levels. The aim of this study was to investigate the clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring. One hundred in-hospital patients, whose 24-hour average blood pressure was higher than 130/80 mmHg even after treatment with more than three antihypertensive drugs, were included in the present analysis. Circadian variation of blood pressure was evaluated by nocturnal fall in systolic blood pressure. Average blood pressures of all patients were high in both daytime and nighttime, 150.0/82.9 and 143.8/78.2 mmHg, respectively. Twenty patients had been treated with hemodialysis or peritoneal dialysis. In 63 patients out of the other 80 patients (79%), estimated glomerular filtration rate (eGFR) was also decreased (blood pressure variation only by renal dysfunction. These results show that a large number of the patients with resistant hypertension suffered from renal dysfunction, although it was difficult to explain altered circadian blood pressure variation based on renal dysfunction alone.

  17. 77 FR 69541 - Technical Report Evaluating the Effectiveness of Tire Pressure Monitoring Systems (TPMS) in...

    Science.gov (United States)

    2012-11-19

    ..., Mathematical Statistician, Mathematical Analysis Division, NVS-421, National Center for Statistics and Analysis... report is an analysis of the data collected through the Tire Pressure Monitoring System-Special Study as... Regulatory Analysis and Evaluation. BILLING CODE 4910-59-P ...

  18. Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography

    Science.gov (United States)

    Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.

    2004-01-01

    High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…

  19. Electronic monitoring of adherence, treatment of hypertension, and blood pressure control

    NARCIS (Netherlands)

    Onzenoort, H.A. van; Verberk, W.J.; Kroon, A.A.; Kessels, A.G.; Neef, C.; Kuy, P.H. van der; Leeuw, P.W. de

    2012-01-01

    BACKGROUND: Although it is generally acknowledged that electronic monitoring of adherence to treatment improves blood pressure (BP) control by increasing patients' awareness to their treatment, little information is available on the long-term effect of this intervention. METHODS: In this observation

  20. Ozone decomposition kinetics on alumina: effects of ozone partial pressure, relative humidity and repeated oxidation cycles

    Directory of Open Access Journals (Sweden)

    R. C. Sullivan

    2004-01-01

    Full Text Available The room temperature kinetics of gas-phase ozone loss via heterogeneous interactions with thin alumina films has been studied in real-time using 254nm absorption spectroscopy to monitor ozone concentrations. The films were prepared from dispersions of fine alumina powder in methanol and their surface areas were determined by an in situ procedure using adsorption of krypton at 77K. The alumina was found to lose reactivity with increasing ozone exposure. However, some of the lost reactivity could be recovered over timescales of days in an environment free of water, ozone and carbon dioxide. From multiple exposures of ozone to the same film, it was found that the number of active sites is large, greater than 1.4x1014 active sites per cm2 of surface area or comparable to the total number of surface sites. The films maintain some reactivity at this point, which is consistent with there being some degree of active site regeneration during the experiment and with ozone loss being catalytic to some degree. The initial uptake coefficients on fresh films were found to be inversely dependent on the ozone concentration, varying from roughly 10-6 for ozone concentrations of 1014 molecules/cm3 to 10-5 at 1013 molecules/cm3. The initial uptake coefficients were not dependent on the relative humidity, up to 75%, within the precision of the experiment. The reaction mechanism is discussed, as well as the implications these results have for assessing the effect of mineral dust on atmospheric oxidant levels.

  1. Experimental determination of carbonation rate in Portland cement at 25°C and relatively high CO2 partial pressure

    Science.gov (United States)

    Hernández-Rodríguez, Ana; Montegrossi, Giordano; Huet, Bruno; Virgili, Giorgio; Orlando, Andrea; Vaselli, Orlando; Marini, Luigi

    2016-04-01

    The aim of this work is to study the alteration of Portland class G Cement at ambient temperature under a relatively high CO2 partial pressure through suitably designed laboratory experiments, in which cement hydration and carbonation are taken into account separately. First, the hydration process was carried out for 28 days to identify and quantify the hydrated solid phases formed. After the completion of hydration, accompanied by partial carbonation under atmospheric conditions, the carbonation process was investigated in a stirred micro-reactor (Parr instrument) with crushed cement samples under 10 bar or more of pure CO2(g) and MilliQ water adopting different reaction times. The reaction time was varied to constrain the reaction kinetics of the carbonation process and to investigate the evolution of secondary solid phases. Chemical and mineralogical analyses (calcimetry, chemical composition, SEM and X-ray Powder Diffraction) were carried out to characterize the secondary minerals formed during cement hydration and carbonation. Water analyses were also performed at the end of each experimental run to measure the concentrations of relevant solutes. The specific surface area of hydrated cement was measured by means of the BET method to obtain the rates of cement carbonation. Experimental outcomes were simulated by means of the PhreeqC software package. The obtained results are of interest to understand the comparatively fast cement alteration in CO2 production wells with damaged casing.

  2. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.

    Science.gov (United States)

    Mattu, G S; Perry, T L; Wright, J M

    2001-06-01

    To compare directly the accuracy of the BPM-100(Beta) monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100(Beta) was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100(Beta) and two trained observers (blinded from each other and from the BPM-100(Beta)) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100(Beta) and the mean of two observers (the reference) was determined and expressed as the mean +/- SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100(Beta) monitor and the reference was -0.62 +/- 6.96 mmHg for systolic blood pressure, -1.48 +/- 4.80 mmHg for diastolic blood pressure and 0.14 +/- 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161-165, 2001). The BPM-100(Beta) is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an 'A' grade according to the British Hypertension Society protocol.

  3. Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

    Directory of Open Access Journals (Sweden)

    Sylvia Siebig, Felix Rockmann, Karl Sabel, Ina Zuber-Jerger, Christine Dierkes, Tanja Brünnler, Christian E. Wrede

    2009-01-01

    Full Text Available Introduction: Close monitoring of arterial blood pressure (BP is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP. Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP®, CN Systems, Graz may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP® in addition to standard monitoring (NIBP, ECG and oxygen saturation. All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP® values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1±34.4 min/patient. All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9±70.3 mg. The mean arterial pressure for CNAP® was 102.4±21.2 mmHg and 106.8±24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP® showed a maximum increase of 30.8±21.7% and a maximum decrease of 22.4±28.3% (mean of all intervals. Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP® improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.

  4. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept.

    Science.gov (United States)

    Halldorsdottir, V G; Dave, J K; Eisenbrey, J R; Machado, P; Zhao, H; Liu, J B; Merton, D A; Forsberg, F

    2014-09-01

    The feasibility of using subharmonic aided pressure estimation (SHAPE) to noninvasively estimate interstitial fluid pressure (IFP) was studied. In vitro, radiofrequency signals, from 0.2 ml/l of Definity (Lantheus Medical Imaging, N Billerica, MA) were acquired within a water-tank with a Sonix RP ultrasound scanner (Analogic Ultrasound, Richmond, BC, Canada; fT/R=6.7/3.35 MHz and fT/R=10/5 MHz) and the subharmonic amplitudes of the signals were compared over 0-50 mmHg. In vivo, five swine with naturally occurring melanomas were studied. Subharmonic signals were acquired from tumours and surrounding tissue during infusion of Definity and compared to needle-based pressure measurements. Both in vitro and in vivo, an inverse linear relationship between hydrostatic pressure and subharmonic amplitude was observed with r(2)=0.63-0.95; p<0.05, maximum amplitude drop 11.36 dB at 10 MHz and -8 dB, and r(2) as high as 0.97; p<0.02 (10 MHz and -4/-8 dB most promising), respectively, indicating that SHAPE may be useful in monitoring IFP.

  5. Wearable and low-stress ambulatory blood pressure monitoring technology for hypertension diagnosis.

    Science.gov (United States)

    Altintas, Ersin; Takoh, Kimiyasu; Ohno, Yuji; Abe, Katsumi; Akagawa, Takeshi; Ariyama, Tetsuri; Kubo, Masahiro; Tsuda, Kenichiro; Tochikubo, Osamu

    2015-01-01

    We propose a highly wearable, upper-arm type, oscillometric-based blood pressure monitoring technology with low-stress. The low-stress is realized by new developments in the hardware and software design. In the hardware design, conventional armband; cuff, is almost halved in volume thanks to a flexible plastic core and a liquid bag which enhances the fitness and pressure uniformity over the arm. Reduced air bag volume enables smaller motor pump size and battery leading to a thinner, more compact and more wearable unified device. In the software design, a new prediction algorithm enabled to apply less stress (and less pain) on arm of the patient. Proof-of-concept experiments on volunteers show a high accuracy on both technologies. This paper mainly introduces hardware developments. The system is promising for less-painful and less-stressful 24-hour blood pressure monitoring in hypertension managements and related healthcare solutions.

  6. Circulating miRNA-155 is realted to blood pressure monitoring parameters

    Institute of Scientific and Technical Information of China (English)

    WU Ying; HUANG Yu-qing; HUANG Cheng; LI Jie; CAI An-ping; YU Xue-ju; ZHOU Dan

    2016-01-01

    Background Studies have shown that miRNA-155 played an important role in the process of development of hypertension.However,there is no date about miRNA-155 and blood pressure monitoring parameters.Therefore,we examined whether in hypertensive patients the expression level of plasma miRNA-155 related to 24-h ambulatory blood pressure monitoring (ABPM) parameters.Methods A cohort of adult patients scheduled to receive physical examination,office and ambulatory blood pressure monitoring.Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) was used to evaluate the expression of selected miRNA-155.The miRNA-155 expression level correlation between blood pressure parameters was assessed using the Spearman correlation coefficient.Results Fifty four essential hypertension patients (25 men;mean age,53.28 ± 9.52 years) and thirty healthy volunteers (15 men;mean age,53.03 ± 5.87 years) were included.We observed higher expression level of miRNA-155 (32.31 ± 2.85 vs 27.21 ± 1.59,P < 0.001) in hypertensive patients compared to healthy control individuals.MiRNA-155 expression level showed significant positive correlation with 24 h Daytime SBP (r =0.681,P < 0.001),24 h Daytime DBP (r =0.473,P < 0.001),24 h Daytime PP (r =0.565,P < 0.001) and dipping (r =0.257,P =0.018),respectively.Conclusions Our study showed that miRNA-155 expression level was associated positively with daytime blood pressure monitoring parameters,as well as blood pressure variability,indicating a possible implication of miRNA-155 in the pathogenesis of hypertension.

  7. Structure and electrical properties of epitaxial SrRuO3 thin films controlled by oxygen partial pressure

    Science.gov (United States)

    Sun, Yan; Zhong, Ni; Zhang, Yuan-Yuan; Qi, Rui-Juan; Huang, Rong; Tang, Xiao-Dong; Yang, Ping-Xiong; Xiang, Ping-Hua; Duan, Chun-Gang

    2016-12-01

    SrRuO3 (SRO) thin films have been grown on (001)-oriented SrTiO3 substrate under various oxygen partial pressures (PO2). A typical step-and-terrace surface morphology and coherent epitaxy characteristics are found in the SRO films for high oxygen pressure growth (PO2 ≥ 10 Pa). Under such high PO2, SRO films exhibit metallic behavior over a temperature range of 10 K ≤ T ≤ 300 K. A detailed study on the transport properties of the metallic SRO films reveals that the resistivity (ρ) follows the law ρ(T)-ρ0 ∝ Tx (x = 0.5, 1.5, or 2). Below ferromagnetic transition temperature (Tc), ρ(T) follows T2 dependence below 30 K and T1.5 dependence at T > 30 K, respectively. This result demonstrates that a transition between the Fermi-liquid (FL) and non-Fermi-liquid (NFL) behavior occurs at ˜30 K. Furthermore, ρ(T) follows T0.5 dependence at T > Tc in the paramagnetic metal state. We have found that the FL to NFL transitions as well as the ferromagnetic transition are corresponding to the abnormal peaks in the magnetoresistance curves, suggesting the coupling of electronic and magnetic properties. The transition temperature of FL to NFL for metallic SRO films is almost independent on PO2, while Tc slightly increases with PO2.

  8. Oxygen partial pressure induced effects on the microstructure and the luminescence properties of pulsed laser deposited TiO2 thin films

    Directory of Open Access Journals (Sweden)

    A. K. Kunti

    2017-01-01

    Full Text Available In this work, the influence of oxygen partial pressure on structural, morphological, and optical properties of TiO2 thin films grown on fused quartz substrate at different oxygen partial pressure by pulsed laser deposition were examined. X-Ray diffraction (XRD patterns show the formation of TiO2 anatase phase deposited at high oxygen pressure. Atomic Force Microscopy (AFM reveals that surface roughness of the films increases with oxygen pressure. Variation of surface morphology of films with increasing oxygen partial pressure was studied by AFM. It is observed that energy band gap of the films increases from 3.27 eV to 3.52 eV with the increase of oxygen pressure and is attributed to the decrease of oxygen defects. TiO2 thin films exhibited blue emission under the excitation of 320 nm wavelength. De-convoluted photoluminescence (PL peaks showed that defect states are responsible for visible emission in TiO2 thin films. The intensity of PL emission associated with oxygen vacancies decreases with increasing oxygen pressure. Photometric characteristic analysis shows that the films deposited 1x10-4 mbar oxygen pressure exhibited intense blue emission with high luminescence efficacy of radiation.

  9. Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

    Science.gov (United States)

    Scardelletti, Maximilian C.; Jordan, Jennifer L.; Meredith, Roger D.; Harsh, Kevin; Pilant, Evan; Usrey, Michael W.; Beheim, Glenn M.; Hunter, Gary W.; Zorman, Christian A.

    2016-01-01

    In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

  10. Nonlinear partial least squares with Hellinger distance for nonlinear process monitoring

    KAUST Repository

    Harrou, Fouzi

    2017-02-16

    This paper proposes an efficient data-based anomaly detection method that can be used for monitoring nonlinear processes. The proposed method merges advantages of nonlinear projection to latent structures (NLPLS) modeling and those of Hellinger distance (HD) metric to identify abnormal changes in highly correlated multivariate data. Specifically, the HD is used to quantify the dissimilarity between current NLPLS-based residual and reference probability distributions. The performances of the developed anomaly detection using NLPLS-based HD technique is illustrated using simulated plug flow reactor data.

  11. Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note

    Directory of Open Access Journals (Sweden)

    Dembinski Rolf

    2009-04-01

    Full Text Available Abstract Background Piezoresistive pressure measurement technique (PRM has previously been applied for direct IAP measurement in a porcine model using two different devices. Aim of this clinical study was to assess both devices regarding complications, reliability and agreement with IVP in patients undergoing elective abdominal surgery. Methods A prospective cohort study was performed in 20 patients randomly scheduled to receive PRM either by a Coach®-probe or an Accurate++®-probe (both MIPM, Mammendorf, Germany. Probes were placed on the greater omentum and passed through the abdominal wall paralleling routine drainages. PRM was compared with IVP measurement by t-testing and by calculating mean difference as well as limits of agreement (LA. Results There were no probe related complications. Due to technical limitations, data could be collected in 3/10 patients with Coach® and in 7/10 patients with Accurate++®. Analysis was carried out only for Accurate++®. Mean values did not differ to mean IVP values. Mean difference to IVP was 0.1 ± 2.8 mmHg (LA: -5.5 to 5.6 mmHg. Conclusion Direct IAP measurement was clinically uneventful. Although results of Accurate++® were comparable to IVP, the device might be too fragile for IAP measurements in the clinical setting. Local ethical committee trial registration: EK2024

  12. Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note

    Science.gov (United States)

    Otto, Jens; Kaemmer, Daniel; Binnebösel, Marcel; Jansen, Marc; Dembinski, Rolf; Schumpelick, Volker; Schachtrupp, Alexander

    2009-01-01

    Background Piezoresistive pressure measurement technique (PRM) has previously been applied for direct IAP measurement in a porcine model using two different devices. Aim of this clinical study was to assess both devices regarding complications, reliability and agreement with IVP in patients undergoing elective abdominal surgery. Methods A prospective cohort study was performed in 20 patients randomly scheduled to receive PRM either by a Coach®-probe or an Accurate++®-probe (both MIPM, Mammendorf, Germany). Probes were placed on the greater omentum and passed through the abdominal wall paralleling routine drainages. PRM was compared with IVP measurement by t-testing and by calculating mean difference as well as limits of agreement (LA). Results There were no probe related complications. Due to technical limitations, data could be collected in 3/10 patients with Coach® and in 7/10 patients with Accurate++®. Analysis was carried out only for Accurate++®. Mean values did not differ to mean IVP values. Mean difference to IVP was 0.1 ± 2.8 mmHg (LA: -5.5 to 5.6 mmHg). Conclusion Direct IAP measurement was clinically uneventful. Although results of Accurate++® were comparable to IVP, the device might be too fragile for IAP measurements in the clinical setting. Local ethical committee trial registration: EK2024 PMID:19383161

  13. Cost estimation of hypertension management based on home blood pressure monitoring alone or combined office and ambulatory blood pressure measurements.

    Science.gov (United States)

    Boubouchairopoulou, Nadia; Karpettas, Nikos; Athanasakis, Kostas; Kollias, Anastasios; Protogerou, Athanase D; Achimastos, Apostolos; Stergiou, George S

    2014-10-01

    This study aims at estimating the resources consumed and subsequent costs for hypertension management, using home blood pressure (BP) monitoring (HBPM) alone versus combined clinic measurements and ambulatory blood pressure monitoring (C/ABPM). One hundred sixteen untreated hypertensive subjects were randomized to use HBPM or C/ABPM for antihypertensive treatment initiation and titration. Health resources utilized within 12-months follow-up, their respective costs, and hypertension control were assessed. The total cost of the first year of hypertension management was lower in HBPM than C/ABPM arm (€1336.0 vs. €1473.5 per subject, respectively; P cost was identical in both arms. There was no difference in achieved BP control and drug expenditure (HBPM: €233.1 per subject; C/ABPM: €247.6 per subject; P = not significant), whereas the cost of BP measurements and/or visits was higher in C/ABPM arm (€393.9 vs. €516.9, per patient, respectively P cost for subsequent years (>1) was €348.9 and €440.2 per subject, respectively for HBPM and C/ABPM arm and €2731.4 versus €3234.3 per subject, respectively (P cost than C/ABPM, and the same trend is observed in 5-year projection. The results on the resources consumption can be used to make cost estimates for other health-care systems.

  14. Variation in intracranial pressure monitoring and outcomes in pediatric traumatic brain injury.

    Science.gov (United States)

    Bennett, Tellen D; Riva-Cambrin, Jay; Keenan, Heather T; Korgenski, E Kent; Bratton, Susan L

    2012-07-01

    To describe between-hospital and patient-level variation in intracranial pressure (ICP) monitoring and to evaluate ICP monitoring in association with hospital features and outcome in children with traumatic brain injury (TBI). Retrospective cohort study. SETTING Children's hospitals participating in the Pediatric Health Information System database (January 2001 to June 2011). Children (aged head Abbreviated Injury Scale scores of at least 3 who were ventilated for at least 96 consecutive hours or who died in the first 4 days after hospital admission. Monitoring of ICP. A total of 4667 children met the study criteria. Hospital mortality was 41% (n = 1919). Overall, 55% of patients (n = 2586) received ICP monitoring. Expected hospital ICP monitoring rates after adjustment for patient age, cardiac arrest, inflicted injury, craniotomy or craniectomy, head Abbreviated Injury Scale score, and Injury Severity Score were 47% to 60%. Observed hospital ICP monitoring rates were 14% to 83%. Hospitals with more observed ICP monitoring, relative to expected, and hospitals with higher patient volumes had lower rates of mortality or severe disability. After adjustment for between-hospital variation and patient severity of injury, ICP monitoring was independently associated with age 1 year and older (odds ratio, 3.1; 95% CI, 2.5-3.8) vs age younger than 1 year. There was significant between-hospital variation in ICP monitoring that cannot be attributed solely to differences in case mix. Hospitals that monitor ICP more frequently and hospitals with higher patient volumes had better patient outcomes. Infants with TBI are less likely to receive ICP monitoring than are older children.

  15. Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

    Science.gov (United States)

    Yoon, Youngzoon; Cho, Jung H; Yoon, Gilwon

    2009-08-01

    Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure (BP) was estimated from pulse transit time (PTT) and PPG waveform. PTT is a time interval between an R-wave of electrocardiography (ECG) and a photoplethysmography (PPG) signal. This method does not require an aircuff and only a minimal inconvenience of attaching electrodes and LED/photo detector sensors on a subject. PTT computed between the ECG R-wave and the maximum first derivative PPG was strongly correlated with systolic blood pressure (SBP) (R = -0.712) compared with other PTT values, and the diastolic time proved to be appropriate for estimation diastolic blood pressure (DBP) (R = -0.764). The percent errors of SBP using the individual regression line (4-11%) were lower than those using the regression line obtained from all five subjects (9-14%). On the other hand, the DBP estimation did not show much difference between the individual regression (4-10%) and total regression line (6-10%). Our developed device had a total size of 7 x 13.5 cm and was operated by single 3-V battery. Biosignals can be measured for 72 h continuously without external interruptions. Through a serial network communication, an external personal computer can monitor measured waveforms in real time. Our proposed method can be used for non-constrained, thus continuous BP monitoring for the purpose of personal healthcare.

  16. [Influence of treatment with olmesartan on ambulatory blood pressure monitoring parameters in patients with arterial hypertension].

    Science.gov (United States)

    Bregvadze, T R; Tseluĭko, V I; Mishchuk, N E

    2013-12-01

    Hypertension is the most common disease of the cardiovascular system. Active treatment of hypertension with adequate control of blood pressure (BP) can prevent complications, improve life quality and increase life expectancy. One of the interesting new antihypertensive agents, from the group of angiotensin receptor blockers is olmesartan. The obvious advantages of ambulatory blood pressure monitoring to traditional one-time measurements of BP make this method perspective for quality control of anti-hypertensive therapy. The aim of this study was to evaluate the influence of treatment with olmesartan on ambulatory blood pressure monitoring parameters in patients with hypertension. 38 out-patients with hypertension at the age of 25-84 years (mean 55,3±10,6) were studied. Patients received olmesartan 20 mg daily as monotherapy (20 patients (52,6%)) or in combination with other antihypertensive agents (18 patients (47,4%)). Treatment continued for 6 months. The complex examination included: measurement of office brachial BP, electrocardiography, echocardiography and ambulatory blood pressure monitoring (ABPM). As a result of treatment, office BP and diurnal BP, according to ABPM, significantly decreased; the favorable circadian BP profile dynamics were found: significantly less frequently observed lack of reduction in BP during night (daily index - non-dipper) - 18% vs. 64% (p treatment of hypertensive patients with olmesartan provides significant decline not only in office BP, but also in diurnal BP, normalizes BP of active and passive periods, also - daily index and reduces BP variability.

  17. Pressure-Saturation Effects from AVO Attributes in CO2 Monitoring of Weyburn Reservoir, Saskatchewan, Canada

    Science.gov (United States)

    Gao, L.; Morozov, I. B.

    2011-12-01

    In order to measure pore-pressure and saturation effects due to CO2 injection, amplitude variation with offset (AVO) could be a most valuable discriminator. The AVO technique is applied to monitoring the Weyburn reservoir, located in southeast Saskatchewan, using 3D/3C surface seismic datasets. A baseline (1999) and two monitor surveys (2001 and 2002) acquired by EnCana as part of the International Energy Agency GHG Weyburn-Midale CO2 Monitoring and Storage Project are included in this study. Two-term linear AVO attributes including the intercept (I), gradient (G), S-wave reflectivity (I-G)/2 and I+G are derived. Attribute I - G is shown to be most sensitive to pressure variations, and I + G - to CO2 saturation. In addition, several secondary attributes based on statistical distributions of (I, G) values are also examined. The time-lapse AVO attributes indicate areas of pore-pressure and potentially CO2 saturation variations between the horizontal injection wells. The results indicate that AVO technology allows estimating reservoir pressure and fluid saturation variations from time-lapse seismic data.

  18. Ambulatory arterial stiffness index derived from 24-hour ambulatory blood pressure monitoring.

    Science.gov (United States)

    Li, Yan; Wang, Ji-Guang; Dolan, Eamon; Gao, Ping-Jin; Guo, Hui-Feng; Nawrot, Tim; Stanton, Alice V; Zhu, Ding-Liang; O'Brien, Eoin; Staessen, Jan A

    2006-03-01

    We hypothesized that 1 minus the slope of diastolic on systolic pressure during 24-hour ambulatory monitoring (ambulatory arterial stiffness index [AASI]) might reflect arterial stiffness. We compared AASI with established measures of arterial stiffness and studied its distribution in Chinese and European populations. We used 90207 SpaceLabs monitors and the SphygmoCor device to measure AASI, central and peripheral pulse pressures, the central (CAIx) and peripheral (PAIx) systolic augmentation indexes, and aortic pulse wave velocity. In 166 volunteers, the correlation coefficient between AASI and pulse wave velocity was 0.51 (Ppressure (r=0.50). AASI increased with age and mean arterial pressure but decreased with body height. Both before and after adjustment for arterial wave reflections by considering height and heart rate as covariates, AASI correlated more (Ppressure. Among normotensive subjects, the 95th percentile of AASI was 0.55 in Chinese and 0.57 in 1617 Europeans enrolled in the International Database on Ambulatory Blood Pressure Monitoring. The upper boundary of the 95% prediction interval of AASI in relation to age ranged from 0.53 at 20 years to 0.72 at 80 years. In conclusion, AASI is a new index of arterial stiffness that can be easily measured under ambulatory conditions. Pending additional validation in outcome studies, normal values of AASI are probably <0.50 and 0.70 in young and older subjects, respectively.

  19. Flying blind: designing and maintaining jointed concrete pavement without monitoring pavement pressure generation

    Science.gov (United States)

    Burke, Martin P., Jr.

    2001-08-01

    The generation of longitudinal pavement pressures or growth of jointed-rigid pavement have been recognized by many engineers for at least a century. The manifestations of this pressure/growth phenomenon, in the form of progressive pavement and bridge damage, are vivid examples of its destructive potential. Yet, only a few researchers have attempted to measure the pressures generated by this phenomenon. None, to the author's knowledge, have attempted to periodically monitor pressure generation for the purpose of either determining and describing pressure generation characteristics or predicting the probability of its abrupt final and destructive manifestations. Because the pavement/growth phenomenon occurs over such a long period of time (a decade or more), it is generally unrecognized, or if recognized, it is poorly understood. Consequently, design and maintenance of jointed rigid pavement continues to be guided more by intuition and personal judgement rather than be replicated research and professional consensus. This paper provides a speculative description of the pavement pressure/growth phenomenon. It also contains an appeal to research professionals to develop instrumentation suitable to monitor generating pavement pressures. The results of such research should finally enable the transportation profession to establish suitable background so that future pavement design and maintenance will be guided so that pressure generation will be minimized and pavement and bridge function and durability will be improved. Otherwise, transportation systems will continue to experience progressive and substantial pavement and bridge damage, commensurate repair costs, and the traveling public will continue to be exposed to occasional but abrupt manifestations of its destructive potential.

  20. Ambulatory blood pressure monitoring early after acute myocardial infarction: development of a new prognostic index.

    Science.gov (United States)

    Antonini, Lanfranco; Pasceri, Vincenzo; Greco, Salvatore; Colivicchi, Furio; Malfatti, Solferina; Pede, Sergio; Guido, Vincenzo; Kol, Amir; Santini, Massimo

    2007-04-01

    The aim of our study was to assess the possible role of a prognostic index based on ambulatory blood pressure monitoring in a large cohort of patients with recent myocardial infarction. The study population included 1335 consecutive patients admitted for ST elevation myocardial infarction and discharged alive from 48 Italian hospitals participating in the multicentric IMPRESSIVE (Infarto Miocardico, Pressione arteriosa e frequenza cardiaca. Studio Italiano di Valutazione Epidemiologica) study. Ambulatory blood pressure monitoring was performed 3 weeks after discharge, with a clinical follow-up of 12 months. End-points included cardiac death and new admission for heart failure. A prognostic index was obtained from the ambulatory blood pressure monitoring variables according to the formula: (220-age)-mean 24 h heart rate (m24hHR)+mean 24 h diastolic blood pressure (m24hDBP). Among many potential predictors only left-ventricular ejection fraction, creatinine levels, Killip class and the prognostic index were independently associated with events during the follow-up. In particular, higher values of the prognostic index were associated with a lower incidence of events, with an odds ratio of 0.958 (95% confidence intervals 0.943-0.974) and a 4% reduction in risk for each point of the prognostic index. Overall incidence of cardiac events was 6-fold higher in patients within the lowest quartile of the prognostic index (< or =148) compared with the other three quartiles (12 vs. 2, 1.4 and 2% respectively in the other three quartiles; P<0.0001). A simple prognostic index based on ambulatory blood pressure monitoring and age may be a useful tool in predicting cardiac death and heart failure in patients with recent myocardial infarction.

  1. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  2. Battery-Free Smart Sock for Abnormal Relative Plantar Pressure Monitoring.

    Science.gov (United States)

    Lin, Xiaoyou; Seet, Boon-Chong

    2017-04-01

    This paper presents a new design of a wearable plantar pressure monitoring system in the form of a smart sock for sensing abnormal relative pressure changes. One advantage of this approach is that with a battery-free design, this system can be powered solely by radio frequency (RF) energy harvested from a radio frequency identification (RFID) reader unit hosted on a smartphone of the wearer. At the same time, this RFID reader can read foot pressure values from an embedded sensor-tag in the sock. A pressure sensing matrix made of conductive fabric and flexible piezo-resistive material is integrated into the sock during the knitting process. Sensed foot pressures are digitized and stored in the memory of a sensor-tag, thus allowing relative foot pressure values to be tracked. The control unit of the smart sock is assembled on a flexible printed circuit board (FPC) that can be strapped to the lower limb and detached easily when it is not in use. Experiments show that the system can operate reliably in both tasks of RF energy harvesting and pressure measurement.

  3. Highly pressurized partially miscible liquid-liquid flow in a micro-T-junction. I. Experimental observations

    Science.gov (United States)

    Qin, Ning; Wen, John Z.; Ren, Carolyn L.

    2017-04-01

    This is the first part of a two-part study on a partially miscible liquid-liquid flow (liquid carbon dioxide and deionized water) which is highly pressurized and confined in a microfluidic T-junction. Our main focuses are to understand the flow regimes as a result of varying flow conditions and investigate the characteristics of drop flow distinct from coflow, with a capillary number, C ac , that is calculated based on the continuous liquid, ranging from 10-3 to 10-2 (10-4 for coflow). Here in part I, we present our experimental observation of drop formation cycle by tracking drop length, spacing, frequency, and after-generation speed using high-speed video and image analysis. The drop flow is chronologically composed of a stagnating and filling stage, an elongating and squeezing stage, and a truncating stage. The common "necking" time during the elongating and squeezing stage (with C ac˜10-3 ) for the truncation of the dispersed liquid stream is extended, and the truncation point is subsequently shifted downstream from the T-junction corner. This temporal postponement effect modifies the scaling function reported in the literature for droplet formation with two immiscible fluids. Our experimental measurements also demonstrate the drop speed immediately following their generations can be approximated by the mean velocity from averaging the total flow rate over the channel cross section. Further justifications of the quantitative analysis by considering the mass transfer at the interface of the two partially miscible fluids are provided in part II.

  4. Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing.

    Science.gov (United States)

    Sipkens, Laura M; Treskes, Kaij; Ariese-Beldman, Karin; Veerman, Derk P; Boer, Christa

    2011-10-01

    Evaluation of autonomic function responses is increasingly important for risk prediction and hemodynamic evaluation in the ambulant and perioperative setting, but requires a noninvasive arterial blood pressure measurement device. This study describes whether a novel noninvasive beat-to-beat arterial blood pressure measurement device (Nexfin HD) is able to reproducibly reflect autonomic function responses in healthy volunteers. Noninvasive beat-to-beat arterial blood pressure measurements (Nexfin HD) were performed in 20 healthy men of 22 ± 3 years. Measurements were performed during supine steady state, controlled breathing (0.125 Hz), passive leg raising, a controlled Valsalva maneuver, and a quick stand test. Finally, relative changes in pulse pressure during autonomic function testing and the test-retest reproducibility were determined. Autonomic function tests induced beat-to-beat arterial blood pressure changes that were accurately monitored by the Nexfin device. The intraclass correlation coefficients for systolic and diastolic arterial blood pressure measurements during supine steady state were agreeable [0.91 (0.82-0.96) and 0.84 (0.69-0.93), respectively]. The reproducibility of blood pressure changes during controlled breathing, passive leg raising, and Valsalva maneuver averaged 0.92 (0.82-0.96), 0.76 (0.50-0.90), and 0.94 (0.89-0.97), respectively. The reproducibility of the pulse pressure variation (PPV) as calculated from controlled breathing-induced changes in the arterial blood pressure (13 ± 5%) was high [0.96 (0.93-0.98)]. This study shows that noninvasive beat-to-beat Nexfin HD arterial blood pressure measurements reproducibly reflect autonomic function responses in healthy volunteers.

  5. Advances in Intracranial Pressure Monitoring and Its Significance in Managing Traumatic Brain Injury

    Directory of Open Access Journals (Sweden)

    Usmah Kawoos

    2015-12-01

    Full Text Available Intracranial pressure (ICP measurements are essential in evaluation and treatment of neurological disorders such as subarachnoid and intracerebral hemorrhage, ischemic stroke, hydrocephalus, meningitis/encephalitis, and traumatic brain injury (TBI. The techniques of ICP monitoring have evolved from invasive to non-invasive—with both limitations and advantages. Some limitations of the invasive methods include short-term monitoring, risk of infection, restricted mobility of the subject, etc. The invasiveness of a method limits the frequency of ICP evaluation in neurological conditions like hydrocephalus, thus hampering the long-term care of patients with compromised ICP. Thus, there has been substantial interest in developing noninvasive techniques for assessment of ICP. Several approaches were reported, although none seem to provide a complete solution due to inaccuracy. ICP measurements are fundamental for immediate care of TBI patients in the acute stages of severe TBI injury. In severe TBI, elevated ICP is associated with mortality or poor clinical outcome. ICP monitoring in conjunction with other neurological monitoring can aid in understanding the pathophysiology of brain damage. This review article presents: (a the significance of ICP monitoring; (b ICP monitoring methods (invasive and non-invasive; and (c the role of ICP monitoring in the management of brain damage, especially TBI.

  6. Advances in Intracranial Pressure Monitoring and Its Significance in Managing Traumatic Brain Injury.

    Science.gov (United States)

    Kawoos, Usmah; McCarron, Richard M; Auker, Charles R; Chavko, Mikulas

    2015-12-04

    Intracranial pressure (ICP) measurements are essential in evaluation and treatment of neurological disorders such as subarachnoid and intracerebral hemorrhage, ischemic stroke, hydrocephalus, meningitis/encephalitis, and traumatic brain injury (TBI). The techniques of ICP monitoring have evolved from invasive to non-invasive-with both limitations and advantages. Some limitations of the invasive methods include short-term monitoring, risk of infection, restricted mobility of the subject, etc. The invasiveness of a method limits the frequency of ICP evaluation in neurological conditions like hydrocephalus, thus hampering the long-term care of patients with compromised ICP. Thus, there has been substantial interest in developing noninvasive techniques for assessment of ICP. Several approaches were reported, although none seem to provide a complete solution due to inaccuracy. ICP measurements are fundamental for immediate care of TBI patients in the acute stages of severe TBI injury. In severe TBI, elevated ICP is associated with mortality or poor clinical outcome. ICP monitoring in conjunction with other neurological monitoring can aid in understanding the pathophysiology of brain damage. This review article presents: (a) the significance of ICP monitoring; (b) ICP monitoring methods (invasive and non-invasive); and (c) the role of ICP monitoring in the management of brain damage, especially TBI.

  7. Partially crystallized Pd nanoparticles decorated TiO2 prepared by atmospheric-pressure cold plasma and its enhanced photocatalytic performance

    Institute of Scientific and Technical Information of China (English)

    Zhijian Xu; Bin Qi; Lanbo Di; Xiuling Zhang

    2014-01-01

    TiO2 decorated with partially crystallized Pd nanoparticles (Pd/TiO2-P) was successfully prepared by atmospheric-pressure dielectric barrier discharge cold plasma. The XRD and XPS analyses proved that Pd ions were reduced to partially crystallized metallic Pd nanoparticles in Pd/TiO2-P. The XPS spectra also indicated that an enhanced metal-support interaction was formed due to the existence of partially crystallized Pd nanoparticles with lower coordination number in Pd/TiO2-P. Photocatalytic activity of Pd/TiO2-P was much higher than that of TiO2 samples decorated with well crystallized Pd nanoparticles.

  8. The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery.

    Directory of Open Access Journals (Sweden)

    Shijiang Liu

    Full Text Available To investigate the correlation and accuracy of transcutaneous carbon dioxide partial pressure (PTCCO2 with regard to arterial carbon dioxide partial pressure (PaCO2 in severe obese patients undergoing laparoscopic bariatric surgery. Twenty-one patients with BMI>35 kg/m(2 were enrolled in our study. Their PaCO2, end-tidal carbon dioxide partial pressure (PetCO2, as well as PTCCO2 values were measured at before pneumoperitoneum and 30 min, 60 min, 120 min after pneumoperitoneum respectively. Then the differences between each pair of values (PetCO2-PaCO2 and. (PTCCO2-PaCO2 were calculated. Bland-Altman method, correlation and regression analysis, as well as exact probability method and two way contingency table were employed for the data analysis. 21 adults (aged 19-54 yr, mean 29, SD 9 yr; weight 86-160 kg, mean 119.3, SD 22.1 kg; BMI 35.3-51.1 kg/m(2, mean 42.1,SD 5.4 kg/m(2 were finally included in this study. One patient was eliminated due to the use of vaso-excitor material phenylephrine during anesthesia induction. Eighty-four sample sets were obtained. The average PaCO2-PTCCO2 difference was 0.9 ± 1.3 mmHg (mean ± SD. And the average PaCO2-PetCO2 difference was 10.3 ± 2.3 mmHg (mean ± SD. The linear regression equation of PaCO2-PetCO2 is PetCO2 = 11.58+0.57 × PaCO2 (r(2 = 0.64, P<0.01, whereas the one of PaCO2-PTCCO2 is PTCCO2 = 0.60 + 0.97 × PaCO2 (r(2 = 0.89. The LOA (limits of agreement of 95% average PaCO2-PetCO2 difference is 10.3 ± 4.6 mmHg (mean ± 1.96 SD, while the LOA of 95% average PaCO2-PTCCO2 difference is 0.9 ± 2.6 mmHg (mean ± 1.96 SD. In conclusion, transcutaneous carbon dioxide monitoring provides a better estimate of PaCO2 than PetCO2 in severe obese patients undergoing laparoscopic bariatric surgery.

  9. DAILY BLOOD PRESSURE MONITORING AND ARTERIAL RIGIDITY DATA IN OSTEOARTHRITIS PATIENTS WITH AND WITHOUT ARTERIAL HYPERTENSION

    Directory of Open Access Journals (Sweden)

    I.A. Kharitonova

    2009-03-01

    Full Text Available We have compared the daily blood pressure monitoring data with arterial wall rigidity parameters in patients with osteoarthritis with and without arterial hypertension. In 32% of patients with osteoarthritis without arterial hypertension we have determined “non-dipper” type and in 16% of patients - “night-peaker”. In case of arterial hypertension 42,8% of patients with osteoarthritis have “night-peaker” type and 22,8% of patients have “non-dipper” type. We have found the correlation between augmentation indices and daily blood pressure parameters.

  10. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring

    Science.gov (United States)

    Schwartz, Gregor; Tee, Benjamin C.-K.; Mei, Jianguo; Appleton, Anthony L.; Kim, Do Hwan; Wang, Huiliang; Bao, Zhenan

    2013-05-01

    Flexible pressure sensors are essential parts of an electronic skin to allow future biomedical prostheses and robots to naturally interact with humans and the environment. Mobile biomonitoring in long-term medical diagnostics is another attractive application for these sensors. Here we report the fabrication of flexible pressure-sensitive organic thin film transistors with a maximum sensitivity of 8.4 kPa-1, a fast response time of 15,000 cycles and a low power consumption of health monitoring and remote diagnostics in cardiovascular medicine.

  11. Double Invasive Blood Pressure Monitoring for Cesarean Delivery in a Pregnant Woman With Aortic Coarctation.

    Science.gov (United States)

    Barcellos, Bruno Mendonça; Loureiro, Fernanda Martins; Sampaio, Livia Fernandes; de Resende, Marco Antonio Cardoso

    2016-08-01

    Aortic coarctation is a discrete narrowing of the proximal thoracic aorta. It is poorly tolerated during pregnancy because of its association with hypertension, cerebrovascular accident, and aortic rupture. We report a case of severe uncorrected congenital aortic coarctation in a 31-year-old symptomatic pregnant woman at 29 weeks of gestation who underwent successful cesarean delivery with an epidural anesthetic technique. Transthoracic echocardiography showed a gradient of 75 mm Hg. To avoid undiagnosed arterial hypotension and inadequate uteroplacental flow distal to the coarctation, double (radial and femoral) invasive arterial blood pressure measurement was used to monitor both pre- and postcoarctation arterial blood pressure.

  12. A CMOS-Based Tactile Sensor for Continuous Blood Pressure Monitoring

    CERN Document Server

    Kirstein, K -U; Salo, T; Hagleitner, C; Vancura, T; Hierlemann, A

    2011-01-01

    A monolithic integrated tactile sensor array is presented, which is used to perform non-invasive blood pressure monitoring of a patient. The advantage of this device compared to a hand cuff based approach is the capability of recording continuous blood pressure data. The capacitive, membrane-based sensor device is fabricated in an industrial CMOS-technology combined with post-CMOS micromachining. The capacitance change is detected by a S?-modulator. The modulator is operated at a sampling rate of 128kS/s and achieves a resolution of 12bit with an external decimation filter and an OSR of 128.

  13. Hypothermic total body washout and intracranial pressure monitoring in Stage IV Reye syndrome.

    Science.gov (United States)

    Lansky, L L; Kalavsky, S M; Brackett, C E; Wallas, C H; Reis, R L

    1977-04-01

    The number of children in this report treated with either TBW or exchange transfusions is small. Case mortality rates among children with Reye syndrome in Stage IV coma tends to be exceedingly high, varying from 50 to 100%. Intracranial pressure monitoring with the subarachnoid screw may have been an additional factor in increasing our survival data in three patients in the TBW group, since it provided continuous monitoring of ICP and allowed judicious administration of mannitol intravenously. Survival of five of six patients without neurologic sequelae in the present series has encouraged us to coninue utilization of TBW in children with Stage IV Reye syndrome.

  14. [Assessment of arterial wall stiffness by 24-hour blood pressure monitoring].

    Science.gov (United States)

    Korneva, V A; Kuznetsova, T Yu

    2016-01-01

    Arterial wall stiffness is an early marker of cardiovascular diseases. The gold standard for assessment of the stiffness of large vessels is presently pulse wave velocity (PWV). Work is in progress on the study of the reference values of PWV in people of different genders and ages. 24-hour blood pressure (BP) monitoring is not only a procedure that can estimate diurnal BP variability, but also monitor the indicators of vascular wall stiffness in a number of cases over a 24-hour period. The given review highlights the pathophysiology of arterial stiffness, methods for its assessment, and the aspects of use in therapeutic practice.

  15. Continuous Right Radial Arterial Pressure Monitoring as a Guide to Dissection of a Thoracic Inlet Neurofibroma.

    Science.gov (United States)

    Ravindra, Madhavi Nishtala

    2015-09-01

    Excision of tumors in the thoracic inlet entail a risk of injury to subclavian vessels due to their close proximity. A right radial artery line can sensitively and continuously monitor the occurrence of right subclavian artery compression and warn the surgeon of its proximity and prevent injury. We describe a case of thoracic inlet tumor in a 12-year-old child, wherein the use of radial artery pressure monitoring guided the surgeon to separate the subclavian artery from the tumor to which it was adherent. © The Author(s) 2015.

  16. Accuracy and Precision of Continuous Noninvasive Arterial Pressure Monitoring Compared with Invasive Arterial Pressure: A Systematic Review and Meta-analysis

    National Research Council Canada - National Science Library

    Kim, Sang-Hyun; Lilot, Marc; Sidhu, Kulraj S; Rinehart, Joseph; Yu, Zhaoxia; Canales, Cecilia; Cannesson, Maxime

    2014-01-01

    BACKGROUND:Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis...

  17. Modeling of a Piezoelectric MEMS Micropump Dedicated to Insulin Delivery and Experimental Validation Using Integrated Pressure Sensors: Application to Partial Occlusion Management

    Directory of Open Access Journals (Sweden)

    S. Fournier

    2017-01-01

    Full Text Available A numerical model based on equivalent electrical networks has been built to simulate the dynamic behavior of a positive-displacement MEMS micropump dedicated to insulin delivery. This device comprises a reservoir in direct communication with the inlet check valve, a pumping membrane actuated by a piezo actuator, two integrated piezoresistive pressure sensors, an anti-free-flow check valve at the outlet, and finally a fluidic pathway up to the patient cannula. The pressure profiles delivered by the sensors are continuously analyzed during the therapy in order to detect failures like occlusion. The numerical modeling is a reliable way to better understand the behavior of the micropump in case of failure. The experimental pressure profiles measured during the actuation phase have been used to validate the numerical modeling. The effect of partial occlusion on the pressure profiles has been also simulated. Based on this analysis, a new management of partial occlusion for MEMS micropump is finally proposed.

  18. Partial results summary for solar domestic hot water monitoring in Pennsylvania

    Science.gov (United States)

    Aungst, W. K.

    Installation procedures, monitoring practices, and results of performance evaluations of 50 HUD-sponsored residential solar flat plate collector systems studied in the field are summarized. The systems consisted of antifreeze, drain-down, and air freeze protection schemes, featured either one- or two-tank thermal storage, and were either roof- or ground-mounted. Residents kept daily records of water flow, temperature, kWh, and elapsed time. The HUD program goals were that one-half of the household daily water needs would be heated by the solar system. An average of 34.5% of the hot water energy was found, although a coefficient of performance of 1.40 was also found, compared to 0.78 and 0.82 for nonsolar water heaters. An average of 9% rate of return on investment was calculated for the solar systems, noting that system efficiencies ranged from 7-79.8%, and the rates of return ranged from 1-22.4%.

  19. Minimization of the energy loss of nuclear power plants in case of partial in-core monitoring system failure

    Science.gov (United States)

    Zagrebaev, A. M.; Ramazanov, R. N.; Lunegova, E. A.

    2017-01-01

    In this paper we consider the optimization problem minimize of the energy loss of nuclear power plants in case of partial in-core monitoring system failure. It is possible to continuation of reactor operation at reduced power or total replacement of the channel neutron measurements, requiring shutdown of the reactor and the stock of detectors. This article examines the reconstruction of the energy release in the core of a nuclear reactor on the basis of the indications of height sensors. The missing measurement information can be reconstructed by mathematical methods, and replacement of the failed sensors can be avoided. It is suggested that a set of ‘natural’ functions determined by means of statistical estimates obtained from archival data be constructed. The procedure proposed makes it possible to reconstruct the field even with a significant loss of measurement information. Improving the accuracy of the restoration of the neutron flux density in partial loss of measurement information to minimize the stock of necessary components and the associated losses.

  20. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study.

    Science.gov (United States)

    Romagnoli, Stefano; Ricci, Zaccaria; Quattrone, Diego; Tofani, Lorenzo; Tujjar, Omar; Villa, Gianluca; Romano, Salvatore M; De Gaudio, A Raffaele

    2014-11-30

    Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the "gold standard" for arterial pressure monitoring. Nonetheless, artifacts due to inappropriate dynamic response of the fluid-filled monitoring systems may lead to clinically relevant differences between actual and displayed pressure values. We sought to analyze the incidence and causes of resonance/underdamping phenomena in patients undergoing major vascular and cardiac surgery. Arterial pressures were measured invasively and, according to the fast-flush Gardner's test, each patient was attributed to one of two groups depending on the presence (R-group) or absence (NR-group) of resonance/underdamping. Invasive pressure values were then compared with the non-invasive ones. A total of 11,610 pulses and 1,200 non-invasive blood pressure measurements were analyzed in 300 patients. Ninety-two out of 300 (30.7%) underdamping/resonance arterial signals were found. In these cases (R-group) systolic invasive blood pressure (IBP) average overestimation of non-invasive blood pressure (NIBP) was 28.5 (15.9) mmHg (P pressure in the R-group was -2.2 (10.6) mmHg and, in the NR-group -1.1 (5.8) mmHg. The mean arterial pressure difference was 7.4 (11.2) mmHg in the R-group and 2.3 (6.4) mmHg in the NR-group. A multivariate logistic regression identified five parameters independently associated with underdamping/resonance: polydistrectual arteriopathy (P = 0.0023; OR = 2.82), history of arterial hypertension (P = 0.0214; OR = 2.09), chronic obstructive pulmonary disease (P = 0.198; OR = 2.61), arterial catheter diameter (20 vs. 18 gauge) (P pressure-time ratio, showed an optimum selected cut-off point of 1.67 mmHg/msec with a specificity of 97% (95% CI: 95.13 to 99.47%) and a sensitivity of 77% (95% CI: 67.25 to 85.28%) and an area under the ROC curve by extended trapezoidal rule of 0.88. Physicians should be aware

  1. Application of Pressure Pulse Test Analysis in CO2 Leakage Detection and Monitoring

    Science.gov (United States)

    Shakiba, M.; Hosseini, S. A.

    2015-12-01

    Over the past decade, numerous research and industrial projects have been devoted to investigate the feasibility and efficiency of carbon dioxide capture, storage, and utilization. Besides the studies over the characteristics of candidate formations for CO2 injection, much attention has been paid to answer the environmental concerns regarding the CO2 leak to overlying formations. To first detect and then track a possible CO2 leak, different techniques have been proposed in the literature; however, most of them examine only a small portion of the formation and have a low resolution for early leak detection. To further increase the extent of the investigation zone and to monitor a large section of the formation in more detail, multi-well testing techniques have received a significant attention. Pressure pulse testing is a multi-well test technique in which a pressure signal generated by periods of injection and shut-in from a pulser well is propagated inside the formation, and the corresponding response is recorded at the observer wells. The recorded pressure response is then analyzed to measure the rock and fluid properties and to monitor the possible changes over the time. In this research study, we have applied frequency methods as well as superposition principle to interpret the pressure pulse test data and monitor the changes in transmissibility and storativity of the formation between the well pairs. We have used synthetic reservoir models and numerical reservoir simulations to produce the pressure pulse test data. The analysis of the simulation results indicated that even a small amount of CO2 leak in the investigation zone can have a measurable effect on the calculated storativity and transmissibility factors. This can be of a great importance when an early leak detection is of interest. Moreover, when multiple wells are available in the formation, the distribution of the calculated parameters can visualize the extent of CO2 leak, which has a great

  2. Designing and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel

    Directory of Open Access Journals (Sweden)

    Akbari H.

    2014-06-01

    Full Text Available Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time. Objective: The aim of this study was to construct blood flow monitoring system on the heel tissue which was under external pressure in order to evaluate the tissue treatment in the ulcer. Methods: To measure the blood flow changes, three infrared optical transmitters were used at the distances of 5, 10, and 15 mm to the receiver. Blood flow changes in heels were assessed in pressures 0, 30, and 60 mmHg. The time features were extracted for analysis from the recorded signal by MATLAB software. Changes of the time features under different pressures were evaluated at the three distances by ANOVA in SPSS software. The level of significance was considered at 0.05. Results: In this study, 15 subjects, including both male and female, with the mean age of 54±7 participated. The results showed that the signal amplitude, power and absolute signal decreased significantly when pressure on the tissue increased in different layers (p<0.05. Heart rate only decreased significantly in pressures more than 30 mmHg (p=0.02. In pressures more than 30 mmHg, in addition to a decrease in the time features, the pattern of blood flow signal changed and it wasn’t the same as noload signal. Conclusion: By detecting the time features, we can reach an early diagnosis to prognosticate the degeneration of the tissue under pressure and it can be recommended as a method to predict bedsores in the heel.

  3. Development of a low pressure chromatographic flow system for monitoring the biodegradation of ofloxacin and ciprofloxacin

    OpenAIRE

    Santos, Inês C.; Mesquita, Raquel R. B.; Amorim, Catarina L.; Castro, Paula M. L.; Rangel,António O. S. S.

    2016-01-01

    In this work, we propose a simple low pressure chromatography method with a high throughput for monitoring the biodegradation of fluoroquinolones. Fluoroquinolones are a class of antibiotics that have been accumulating in the environment as a consequence of their release from different sources, namely hospital waste. It has been found that wastewater treatment plants are not able to completely remove this type of micro-pollutants and so, alternative solutions are necessary. Some biodegradatio...

  4. Ambulatory Blood Pressure Monitoring Profile as a Useful Prognostic Tool in Patients with Primary Hypertension

    OpenAIRE

    Mohamed, A. L.; Katiman, E; Hassan, J Abu

    2003-01-01

    Ambulatory blood pressure monitoring (ABPM) devices are increasingly being used in the assessment of hypertension. The purpose of the study was to investigate patient’s diurnal BP variation and to further determine the differences of BP readings between male and female patients and the effects of age in patients who attended the clinic with essential hypertension. In addition, evidence of relationship between the parameters recorded by 24-hour ABPM was also investigated. This study was conduc...

  5. Continuous monitoring of blood pressure in children and adolescents,a review of the literature.

    Science.gov (United States)

    Mercado, Arlene B

    2008-08-01

    Continuous or ambulatory blood pressure monitoring (CBPM or ABPM) is becoming a useful tool in the early detection of hypertension in children and adolescents. With increased obesity in pediatrics, chronic diseases such as hypertension, diabetes, dyslipidemia and metabolic syndrome which was more commonly seen in adults in the early years, can now be seen in this population. This review provides the clinical reports of the use of CBPM for diagnosis and management of hypertension in the pediatric population.

  6. The tympanic membrane displacement analyser for monitoring intracranial pressure in children

    OpenAIRE

    Gwer, Samson; Sheward, Victoria; Birch, Anthony; Marchbanks, Robert; Idro, Richard; Newton, Charles R.; Kirkham, Fenella J; Lin, Jean-Pierre; Lim, Ming

    2013-01-01

    Purpose Raised intracranial pressure (ICP) is a potentially treatable cause of morbidity and mortality but tools for monitoring are invasive. We sought to investigate the utility of the tympanic membrane displacement (TMD) analyser for non-invasive measurement of ICP in children. Methods We made TMD observations on normal and acutely comatose children presenting to Kilifi District Hospital (KDH) at the rural coast of Kenya and on children on follow-up for idiopathic intracranial hypertension ...

  7. The tympanic membrane displacement analyser for monitoring intracranial pressure in children

    OpenAIRE

    Gwer, Samson; Sheward, Victoria; Birch, Anthony; Marchbanks, Robert; Idro, Richard; Newton, Charles R; Kirkham, Fenella J.; Lin, Jean-Pierre; Lim, Ming

    2013-01-01

    Purpose Raised intracranial pressure (ICP) is a potentially treatable cause of morbidity and mortality but tools for monitoring are invasive. We sought to investigate the utility of the tympanic membrane displacement (TMD) analyser for non-invasive measurement of ICP in children. Methods We made TMD observations on normal and acutely comatose children presenting to Kilifi District Hospital (KDH) at the rural coast of Kenya and on children on follow-up for idiopathic intracranial hypertension ...

  8. Clinical application of invasive intracranial pressure monitoring after severe traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Xia LI

    2011-12-01

    Full Text Available Objective The current study aims to investigate the effects of different intracranial pressure(ICP monitoring means on the prognosis of severe traumatic brain injury,and to determine the significance of all kinds of intracranial pressure monitoring methods for treating severe traumatic brain injury clinically.Methods From January 2009 to June 2010,a total of 201 cases of severe traumatic brain injury(STBI who received operation treatment were collected and divided into A,B,and C groups based on the positions of the ICP probes and the placement methods.ICP monitoring probes were placed in the ventricle of the brain,parenchyma,or under the putamen,on the basis of the routine operation.Lumbar puncture was done once a day for three to seven days after operation.The Ncurolymph pressure and ICP value that are simultaneously shown in the ICP monitoring device were recorded to calculate the difference between them and to conduct comparison among the groups.The corresponding dehydration treatment was made based on the ICP value after operation to record the duration of use and dosage of the dehydrating agent,operation time,occurrence of all kinds of complications,and the prognosis of patients,and to create a comparison among the groups.Results The different values between the ICP monitoring values and ncurolymph pressure in the A,B,and C groups were 22.4±3.6,20.8±4.1,and 12.3±11.5 mmH2O,respectively. The dosage and durationof use of mannitol in group C were significantly higher than those in groups A and B(P < 0.01,whereas the incidence of pulmonary infection and electrolyte disturbance in group C was higher than those in groups A and B(P < 0.01.However,no significant difference of prognosis was observed among the three groups.The operating duration of group A was significantly longer than those of groups B and C(P < 0.01.However,the overall prognosis of the patients in the three groups had no significant difference.The operation time of group A was

  9. Fluctuation of Brain Tissue Oxygen Partial Pressure: A Biochemical Landmark in the Arctic Ground Squirrel's Spontaneous Arousal

    Directory of Open Access Journals (Sweden)

    Yi L. Ma

    2011-01-01

    Full Text Available Hibernation in the Arctic ground Squirrel (AGS is a regulated, adaptive response to arctic environmental conditions. Problem statement: Regional brain Blood Flow (rCBF has been observed to increase dramatically during arousal in hibernators. However, the real time dynamic change in PtO2 during arousal has not been studied, we hypothesized that PtO2 is Interdependent of Tbrain and a key component in the arousal process. Approach: Simultaneous in vivo measurements of PtO2 and brain temperature (Tbrain in conjunction with oxygen consumption (V02 were conducted in the striatum of non-sedated, non-anesthetized Arctic ground squirrels during spontaneous arousal from hibernation. Results: A dramatic fluctuation of brain tissue oxygen partial pressure (PtO2 is associated with the complex phenomena of spontaneous arousal. In this study, we observed that: (1 a PtO2 elevation precedes changes in Tbrain and V02; (2 PtO2 changes do not correlate with changes in V02 during arousal and (3, endogenous O2 shift from O2 enriched blood to brain in hibernating AGS induces an arousal with the pharmaceutical chemical, efaproxiral (RSR-13. Conclusion: The four turning points of PtO2 appearing at different Tbrain during arousal suggest that changes in PtO2 are Tbrain interdependent and support the concept that arousal from hibernation is complex process invoking different feedbacks.

  10. Changes in the partial pressure of carbon dioxide in the Mauritanian–Cap Vert upwelling region between 2005 and 2012

    Directory of Open Access Journals (Sweden)

    M. González-Dávila

    2017-08-01

    Full Text Available Coastal upwellings along the eastern margins of major ocean basins represent regions of large ecological and economic importance due to the high biological productivity. The role of these regions for the global carbon cycle makes them essential in addressing climate change. The physical forcing of upwelling processes that favor production in these areas are already being affected by global warming, which will modify the intensity of upwelling and, consequently, the carbon dioxide cycle. Here, we present monthly high-resolution surface experimental data for temperature and partial pressure of carbon dioxide in one of the four most important upwelling regions of the planet, the Mauritanian–Cap Vert upwelling region, from 2005 to 2012. This data set provides direct evidence of seasonal and interannual changes in the physical and biochemical processes. Specifically, we show an upwelling intensification and an increase of 0.6 Tg yr−1 in CO2 outgassing due to increased wind speed, despite increased primary productivity. This increase in CO2 outgassing together with the observed decrease in sea surface temperature at the location of the Mauritanian Cap Blanc, 21° N, produced a pH rate decrease of −0.003 ± 0.001 yr−1.

  11. Effect of cerium addition on oxidation behavior of 2SCr20Ni alloy under lowoxygen partial pressure

    Institute of Scientific and Technical Information of China (English)

    SHAO Mingzeng; CUI Lishan; ZHENG Yanjun; XING Linlin

    2012-01-01

    The influence of Ce addition on the oxidation behavior of 25Cr20Ni alloy at 950 ℃ under low oxygen partial pressure was investigated.The oxidized samples were characterized by using X-ray diffraction (XRD),scanning electron microscopy (SEM),energy dispersive X-ray spectroscopy (EDS),and scratch tester to obtain the oxide phases,morphology,thickness,composition and adhesion property of the oxide scales.The experiment results indicated that a small amount of Ce addition (0.02 wt.% or 0.05 wt.%) promoted oxidation resistance and inhibited the growth of the needlelike oxide.The Ce addition also decreased the formation of MnCr2O4 but promoted the SiO2 formation underneath the Cr2O3,which largely contributed to the improvement of oxide scale spallation resistance.For the sample with 0.3 wt.% Ce addition,the oxidation rate significantly increased and the spallation resistance of the oxide scale decreased.

  12. Changes in the partial pressure of carbon dioxide in the Mauritanian-Cap Vert upwelling region between 2005 and 2012

    Science.gov (United States)

    González-Dávila, Melchor; Magdalena Santana Casiano, J.; Machín, Francisco

    2017-08-01

    Coastal upwellings along the eastern margins of major ocean basins represent regions of large ecological and economic importance due to the high biological productivity. The role of these regions for the global carbon cycle makes them essential in addressing climate change. The physical forcing of upwelling processes that favor production in these areas are already being affected by global warming, which will modify the intensity of upwelling and, consequently, the carbon dioxide cycle. Here, we present monthly high-resolution surface experimental data for temperature and partial pressure of carbon dioxide in one of the four most important upwelling regions of the planet, the Mauritanian-Cap Vert upwelling region, from 2005 to 2012. This data set provides direct evidence of seasonal and interannual changes in the physical and biochemical processes. Specifically, we show an upwelling intensification and an increase of 0.6 Tg yr-1 in CO2 outgassing due to increased wind speed, despite increased primary productivity. This increase in CO2 outgassing together with the observed decrease in sea surface temperature at the location of the Mauritanian Cap Blanc, 21° N, produced a pH rate decrease of -0.003 ± 0.001 yr-1.

  13. Mycorrhizas improve nitrogen nutrition of Trifolium repens after 8 yr of selection under elevated atmospheric CO2 partial pressure.

    Science.gov (United States)

    Gamper, Hannes; Hartwig, Ueli A; Leuchtmann, Adrian

    2005-08-01

    Altered environmental conditions may change populations of arbuscular mycorrhizal fungi and thereby affect mycorrhizal functioning. We investigated whether 8 yr of free-air CO2 enrichment has selected fungi that differently influence the nutrition and growth of host plants. In a controlled pot experiment, two sets of seven randomly picked single spore isolates, originating from field plots of elevated (60 Pa) or ambient CO2 partial pressure (pCO2), were inoculated on nodulated Trifolium repens (white clover) plants. Fungal isolates belonged to the Glomus claroideum or Glomus intraradices species complex, and host plants were clonal micropropagates derived from nine genets. Total nitrogen (N) concentration was increased in leaves of plants inoculated with fungal isolates from elevated-pCO2 plots. These isolates took up nearly twice as much N from the soil as isolates from ambient-pCO2 plots and showed much greater stimulation of biological N2 fixation. The morpho-species identity of isolates had a more pronounced effect on N2 fixation and on root length colonized than isolate identity. We conclude that rising atmospheric pCO2 may select for fungal strains that will help their host plants to meet increased N demands. Copyright New Phytologist (2005).

  14. Ionic conductivity ageing investigation of 1Ce10ScSZ in different partial pressures of oxygen

    DEFF Research Database (Denmark)

    Omar, Shobit; Belda, Adriana; Escardino, Agustín

    2011-01-01

    The conductivity and its ageing behaviour has been determined for zirconia co-doped with 10 mol% of Sc2O3 and 1 mol% CeO2 in different partial pressures of oxygen at 600 °C. After 3000 h, samples kept in air, in a humidified mixture of H2/N2 and in humidified H2 exhibited loss in the ionic...... conductivity of 9%, 19% and 25%, respectively. The conductivity degradation rates after the first 1000 h were 1.5%/1000 h in air and 4.3%/1000 h in humidified H2. For all atmospheres, after 3000 h at 600 °C the conductivity value remained above 10 mS/cm, the minimum value required for viable solid oxide fuel...... of the reduction front. The core/shell model was applied on the aged reduced sample, and the conductivity of the reduced region is estimated to be 27% lower than the unaged sample. The conductivity behaviour upon re-oxidation is also investigated in air at 600 °C. The conductivity recovers significantly...

  15. The jumbo squid, Dosidicus gigas (Ommastrephidae), living in oxygen minimum zones I: Oxygen consumption rates and critical oxygen partial pressures

    Science.gov (United States)

    Trueblood, Lloyd A.; Seibel, Brad A.

    2013-10-01

    Dosidicus gigas is a large, metabolically active, epipelagic squid known to undertake diel vertical migrations across a large temperature and oxygen gradient in the Eastern Pacific. Hypoxia is known to cause metabolic suppression in D. gigas. However, the precise oxygen level at which metabolic suppression sets in is unknown. Here we describe a novel ship-board swim tunnel respirometer that was used to measure metabolic rates and critical oxygen partial pressures (Pcrit) for adult squids (2-7kg). Metabolic rate measurements were validated by comparison to the activity of the Krebs cycle enzyme, citrate synthase, in mantle muscle tissue (2-17kg). We recorded a mean routine metabolic rate of 5.91μmolg-1h-1 at 10°C and 12.62μmolg-1h-1 at 20°C. A temperature coefficient, Q10, of 2.1 was calculated. D. gigas had Pcrits of 1.6 and 3.8kPa at 10 and 20°C, respectively. Oxygen consumption rate (MO2) varied with body mass (M) according to MO2=11.57M-0.12±0.03 at 10°C. Citrate synthase activity varied with body mass according to Y=9.32M-0.19±0.02.

  16. Quadratic function between arterial partial oxygen pressure and mortality risk in sepsis patients: an interaction with simplified acute physiology score.

    Science.gov (United States)

    Zhang, Zhongheng; Ji, Xuqing

    2016-10-13

    Oxygen therapy is widely used in emergency and critical care settings, while there is little evidence on its real therapeutic effect. The study aimed to explore the impact of arterial oxygen partial pressure (PaO2) on clinical outcomes in patients with sepsis. A large clinical database was employed for the study. Subjects meeting the diagnostic criteria of sepsis were eligible for the study. All measurements of PaO2 were extracted. The primary endpoint was death from any causes during hospital stay. Survey data analysis was performed by using individual ICU admission as the primary sampling unit. Quadratic function was assumed for PaO2 and its interaction with other covariates were explored. A total of 199,125 PaO2 samples were identified for 11,002 ICU admissions. Each ICU stay comprised 18 PaO2 samples in average. The fitted multivariable model supported our hypothesis that the effect of PaO2 on mortality risk was in quadratic form. There was significant interaction between PaO2 and SAPS-I (p = 0.007). Furthermore, the main effect of PaO2 on SOFA score was nonlinear. The study shows that the effect of PaO2 on mortality risk is in quadratic function form, and there is significant interaction between PaO2 and severity of illness.

  17. Partial hydrophilic modification of biaxially oriented polypropylene film by an atmospheric pressure plasma jet with the allylamine monomer

    Science.gov (United States)

    Chen, W. X.; Yu, J. S.; Hu, W.; Chen, G. L.

    2016-11-01

    In this paper, the partial modification of the biaxially oriented polypropylene (BOPP) film for potential biological and packaging applications was achieved via hydrophilic modification using atmospheric pressure plasma jet (APPJ). In the APPJ system, the allylamine (ALA) monomer was polymerized on the BOPP surface by either the Ar/O2 or the He/O2 plasma. The results showed that plasmatic modification created many micro/nano sized holes on the BOPP film, which increased the surface roughness dramatically and the increased roughness enhanced the combining intensity between the BOPP film and the ALA polymer. However, such a plasmatic modification increased the water vapor permeability. The FTIR and XPS characterizations showed that the amine groups were grafted onto the BOPP film, and the contact angle of the BOPP film decreases from 98.5° to 8°. Compared with the BOPP films treated by the Ar or He plasma, the barrier property of the modified BOPP film increased significantly when the ALA polymer was incorporated. The bio-affinity/toxicity of ALA polymer was illustrated by the attachment of the cultured SMMC-7721 hepatoma cells on the modified BOPP film. The significant enhancement in the cell density indicated that modified BOPP film was highly bio-compatible and non-toxic, especially treated with the Ar/O2/ALA plasma.

  18. Phase pure epitaxial growth of BiFeO3 films: An effect of oxygen partial pressure

    Science.gov (United States)

    Chandra Das, Sadhan; Majumdar, Abhijit; Katiyal, Sumant; Poojitha, Bommareddy; Saha, Surajit; Shripathi, T.

    2017-09-01

    We report the growth of bismuth ferrite, BiFeO3 (BFO), thin films by varying oxygen partial pressure (230, 100 and 10mTorr) in pulsed laser deposition system using 10% bismuth excess BFO target on SrTiO3 (001) [STO] substrates at 700 °C each for 15 min duration. X-ray diffraction shows the presence of an impurity phase along with BFO peaks for 230 mTorr film, whereas oriented BFO film is observed for 100 mTorr film with a small impurity phase. Importantly, epitaxial growth of BFO is observed without any impurity phase and with sufficiently increased strain for the 10 mTorr film, confirmed by the reciprocal space mapping of (002) and (103) reflections. UV-Raman measurements have been performed on as grown films and the 10 mTorr BFO film after annealing up to 500 °C to check its thermal stability. Atomic force microscopic (AFM) study reveals that the 10 mTorr BFO film shows a lower roughness as compared to 100 mTorr and 230 mTorr films. Fast Fourier Transform (FFT) analysis in AFM shows a fourfold symmetric structure suggesting the presence of both modes of pattern-orientation in 230 mTorr BFO film whereas an elongated bright spot along the y-direction in the FFT of 10 mTorr BFO film suggests the growth tendency to be along the y-direction.

  19. Effect of CO2 partial pressure on SCC behavior of welded X80 pipeline in simulated soil solution

    Institute of Scientific and Technical Information of China (English)

    Ming WU; Xu CHEN; Chuan HE; Jun XIAO

    2011-01-01

    The stress corrosion cracking (SCC) behavior of welded X80 pipeline steel in simulated Ku'erle soil solution was studied by means of electrochemical impedance spectroscopy (EIS) and slow strain rate tests (SSRT). The microstructure of the welded steel was observed by optical microscopy (OM). It is demonstrated that the microstructure of the weld metal consists of acicular ferrite and grain boundary ferrite,while that of heat affected zone (HAZ) is a mixture of acicular ferrite and bainitic ferrite microconstituents. The microstructure of the base steel is composed of ferrite and pearlite.The anodic dissolution of X80 pipeline steel in simulated Ku'erle soil solution could be enhanced and the SCC sensitivity increased with the increase of CO2 partial pressure. The SCC mechanism of X80 pipeline is a mixing mechanism of hydrogen embrittlement combined with anodic dissolution,and the hydrogen embrittlement plays a leading role. The higher SCC sensitivity of the weld metal was attributed to the metallurgical transformation,local hardening and residual stress.

  20. Low parameter model to monitor bottom hole pressure in vertical multiphase flow in oil production wells

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2016-09-01

    Full Text Available The importance of the flow patterns through petroleum production wells proved for upstream experts to provide robust production schemes based on the knowledge about flow behavior. To provide accurate flow pattern distribution through production wells, accurate prediction/representation of bottom hole pressure (BHP for determining pressure drop from bottom to surface play important and vital role. Nevertheless enormous efforts have been made to develop mechanistic approach, most of the mechanistic and conventional models or correlations unable to estimate or represent the BHP with high accuracy and low uncertainty. To defeat the mentioned hurdle and monitor BHP in vertical multiphase flow through petroleum production wells, inventive intelligent based solution like as least square support vector machine (LSSVM method was utilized. The evolved first-break approach is examined by applying precise real field data illustrated in open previous surveys. Thanks to the statistical criteria gained from the outcomes obtained from LSSVM approach, the proposed least support vector machine (LSSVM model has high integrity and performance. Moreover, very low relative deviation between the model estimations and the relevant actual BHP data is figured out to be less than 6%. The output gained from LSSVM model are closed the BHP while other mechanistic models fails to predict BHP through petroleum production wells. Provided solutions of this study explicated that implies of LSSVM in monitoring bottom-hole pressure can indicate more accurate monitoring of the referred target which can lead to robust design with high level of reliability for oil and gas production operation facilities.

  1. Behavior of plant plasma membranes under hydrostatic pressure as monitored by fluorescent environment-sensitive probes.

    Science.gov (United States)

    Roche, Yann; Klymchenko, Andrey S; Gerbeau-Pissot, Patricia; Gervais, Patrick; Mély, Yves; Simon-Plas, Françoise; Perrier-Cornet, Jean-Marie

    2010-08-01

    We monitored the behavior of plasma membrane (PM) isolated from tobacco cells (BY-2) under hydrostatic pressures up to 3.5kbar at 30 degrees C, by steady-state fluorescence spectroscopy using the newly introduced environment-sensitive probe F2N12S and also Laurdan and di-4-ANEPPDHQ. The consequences of sterol depletion by methyl-beta-cyclodextrin were also studied. We found that application of hydrostatic pressure led to a marked decrease of hydration as probed by F2N12S and to an increase of the generalized polarization excitation (GPex) of Laurdan. We observed that the hydration effect of sterol depletion was maximal between 1 and 1.5 kbar but was much less important at higher pressures (above 2 kbar) where both parameters reached a plateau value. The presence of a highly dehydrated gel state, insensitive to the sterol content, was thus proposed above 2.5 kbar. However, the F2N12S polarity parameter and the di-4-ANEPPDHQ intensity ratio showed strong effect on sterol depletion, even at very high pressures (2.5-3.5 kbar), and supported the ability of sterols to modify the electrostatic properties of membrane, notably its dipole potential, in a highly dehydrated gel phase. We thus suggested that BY-2 PM undergoes a complex phase behavior in response to the hydrostatic pressure and we also emphasized the role of phytosterols to regulate the effects of high hydrostatic pressure on plant PM.

  2. Noninvasive arterial blood pressure waveform monitoring using two- element ultrasound system.

    Science.gov (United States)

    Seo, Joohyun; Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2015-04-01

    This work details noninvasive arterial blood pressure (ABP) waveform estimation based on an arterial vessel cross-sectional area measurement combined with an elasticity measurement of the vessel, represented by pulse wave velocity (PWV), using a two-element ultrasound system. The overall ABP waveform estimation is validated in a custom-designed experimental setup mimicking the heart and an arterial vessel segment with two single element transducers, assuming a constant hemodynamic system. The estimation of local PWV using the flow-area method produces unbiased elasticity estimation of the tube in a pressure waveform comparison. The measured PWV using 16 cardiac cycles of data is 8.47 + 0.63 m/s with an associated scaling error of -1.56 + 14.0% in a direct pressure waveform comparison, showing negligible bias error on average. The distension waveform obtained from a complex cross-correlation model estimator (C3M) reliably traces small pressure changes reflected by the diameter change. The excellent agreement of an estimated pressure waveform to the reference pressure waveform suggests the promising potential of a readily available, inexpensive, and portable ABP waveform monitoring device.

  3. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  4. Temporal resilience and dynamics of anaerobic methane-oxidizing microbial communities to short-term changes in methane partial pressures

    Science.gov (United States)

    Klasek, S.; Tiantian, Y.; Torres, M. E.; Colwell, F. S.; Wang, F.; Liang, L.

    2015-12-01

    Marine sediments produce tens to hundreds of teragrams of methane annually, which is released from the seabed at thousands of cold seeps distributed globally along continental margins. Around 80-90% of this methane is consumed in shallower sediment layers before reaching the hydrosphere, in a microbially-mediated process known as anaerobic oxidation of methane (AOM) However, cold seeps appear to exhibit temporal variation in gas flux intensity, and AOM filter efficiency at cold seeps generally decreases with fluid flow rate. To our knowledge, the degree to which temporal heterogeneity in subsurface methane flux stimulates AOM community growth and adaptation to increased methane concentrations has not been investigated. Static high-pressure bioreactors were used to incubate sulfate-methane transition zone (SMTZ) and methanogenic zone sediments underlying a Mediterranean mud volcano gas flare under in situ temperature and pressure at 8 MPa methane. Sulfide production rates of 0.4 μmol/cm3/day in both sediment regimes after 4 months of incubation suggested the resilience of the marine subsurface methane filter may extend well below the SMTZ (40 cm). Similar incubations of SMTZ samples from below a gas flare off Svalbard at saturating (3.8 MPa) and 0.2 MPa methane are being sampled after 1 week, 4 weeks, and 4 months; sulfide production rates of 8-18 nmol/cm3/day were first observed after 4 weeks of incubation. Sediment samples at all specified time points for both sets of incubations were collected for nucleic acid extraction and cell fixation. Anaerobic methanotrophic archaea (ANME) and sulfate-reducing bacteria (SRB) are expected dominant taxa in enriched and non-enriched communities. 16S rDNA community analysis is expected to reveal additional microbial players involved in the short-term adaptation to higher methane partial pressures in the marine subsurface. Increased AOM community activity (RNA/DNA ratio) and copy numbers of methane cycling transcripts (mcr

  5. Monitoring of injected CO2 at two commercial geologic storage sites with significant pressure depletion and/or re-pressurization histories: A case study

    Directory of Open Access Journals (Sweden)

    Dayanand Saini

    2017-03-01

    The monitoring technologies that have been used/deployed/tested at both the normally pressured West Hastings and the subnormally pressured Bell Creek storage sites appear to adequately address any of the potential “out of zone migration” of injected CO2 at these sites. It would be interesting to see if any of the collected monitoring data at the West Hastings and the Bell Creek storage sites could also be used in future to better understand the viability of initially subnormally pressured and subsequently depleted and re-pressurized oil fields as secure geologic CO2 storage sites with relatively large storage CO2 capacities compared to the depleted and re-pressurized oil fields that were initially discovered as normally pressured.

  6. An intelligent system for continuous blood pressure monitoring on remote multi-patients in real time

    CERN Document Server

    Marani, Roberto

    2012-01-01

    In this paper we present an electronic system to perform a non-invasive measurement of the blood pressure based on the oscillometric method, which does not suffer from the limitations of the well-known auscultatory one. Moreover the proposed system is able to evaluate both the systolic and diastolic blood pressure values and makes use of a microcontroller and a Sallen-Key active filter. With reference to other similar devices, a great improvement of our measurement system is achieved since it performs the transmission of the systolic and diastolic pressure values to a remote computer. This aspect is very important when the simultaneous monitoring of multi-patients is required. The proposed system, prototyped and tested at the Electron Devices Laboratory (Electrical and Information Engineering Department) of Polytechnic University of Bari, Italy, is characterized by originality, by plainness of use and by a very high level of automation (so called intelligent system).

  7. Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

    Science.gov (United States)

    Mukkamala, Ramakrishna; Hahn, Jin-Oh; Inan, Omer T; Mestha, Lalit K; Kim, Chang-Sei; Töreyin, Hakan; Kyal, Survi

    2015-08-01

    Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work toward putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach.

  8. Quantitative Raman Spectroscopy to monitor microbial metabolism in situ under pressure

    Science.gov (United States)

    Picard, A.; Daniel, I.; Oger, P.

    2006-12-01

    Although high hydrostatic pressure (HHP) biotopes are ubiquitous on Earth, little is known about the metabolism of piezophile organisms. Cell culture under HHP can be technically challenging, and equipment- dependent. In addition, the depressurization step required for analysis can lead to erroneous data. Therefore, to understand how piezophile organisms react to pressure, it is crucial to be able to monitor their activity in situ under HHP. We developed the use of Quantitative Raman Spectroscopy (QRS, 1) to monitor in situ the metabolism of organic molecules. This technique is based on the specific spectral signature of an analyte from which its concentration can be deduced. An application of this technique to the monitoring of alcoholic fermentation by the piezotolerant micro-eucaryote Saccharomyces cerevisiae is presented. Ethanol fermentation from glucose was monitored during 24h from ambient P up to 100 MPa in the low- pressure Diamond Anvil Cell (lpDAC, 2). The experimental compression chamber consisted in a 300 μm-thick Ni gasket in which a 500 μm-diameter hole was drilled. Early-stationnary yeast cells were inoculated into fresh low-fluorescence medium containing 0.15 M of glucose. Ethanol concentration was determined in situ by QRS using the symmetric C-C stretching mode of ethanol at 878 cm-1 normalizing the data to the intensity of the sulfate S-O stretching mode at 980 cm-1. In our setup, the detection limit of ethanol is lower than 0.05 mM with a precision below 1%. At ambient P, ethanol production in the lpDAC and in control experiments proceeds with the same kinetics. Thus, yeast is not affected by its confinement. This is further confirmed by its ability to bud with a generation time similar to control experiments performed in glass tubes at ambient pressure inside the lpDAC. Ethanol production by yeast occurs to at least 65 MPa (3). At 10 MPa, fermentation proceeds 3 times faster than at ambient P. Fermentation rates decrease linearly from 20 to

  9. Effects of Temperature, Oxygen Partial Pressure, and Materials Selection on Slag Infiltration into Porous Refractories for Entrained-Flow Gasifiers

    Science.gov (United States)

    Kaneko, Tetsuya Kenneth

    The penetration rate of molten mineral contents (slag) from spent carbonaceous feedstock into porous ceramic-oxide refractory linings is a critical parameter in determining the lifecycle of integrated gasification combined cycle energy production plants. Refractory linings that withstand longer operation without interruption are desirable because they can mitigate consumable and maintenance costs. Although refractory degradation has been extensively studied for many other high-temperature industrial processes, this work focuses on the mechanisms that are unique to entrained-flow gasification systems. The use of unique feedstock mixtures, temperatures from 1450 °C to 1600 °C, and oxygen partial pressures from 10-7 atm to 10-9 atm pose engineering challenges in designing an optimal refractory material. Experimentation, characterization, and modeling show that gasifier slag infiltration into porous refractory is determined by interactions between the slag and the refractory that either form a physical barrier that impedes fluid flow or induce an increased fluid viscosity that decelerates the velocity of the fluid body. The viscosity of the slag is modified by the thermal profile of the refractory along the penetration direction as well as reactions between the slag and refractory that alter the chemistry, and thereby the thermo-physical properties of the fluid. Infiltration experiments reveal that the temperature gradient inherently present along the refractory lining limits penetration. A refractory in near-isothermal conditions demonstrates deeper slag penetration as compared to one that experiences a steeper thermal profile. The decrease in the local temperatures of the slag as it travels deeper into the refractory increases the viscosity of the fluid, which in turn slows the infiltration velocity of fluid body into the pores of the refractory microstructure. With feedstock mixtures that exhibit high iron-oxide concentrations, a transition-metal-oxide, the oxygen

  10. End-tidal carbon dioxide (ETCO2) can replace methods for measuring partial pressure of carbon dioxide (PCO2) in pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen

    2017-01-01

    We compared end-tidal carbon dioxide (ETCO2) with partial pressure of carbon dioxide (PCO2) in domestic pigs anesthetized for neuroscience. There was good agreement between ETCO2 and PCO2 under both hypocapnia, normocapnia, and hypercapnia conditions. ETCO2 saves time by continually providing...

  11. Effects of ambient and acute partial pressures of ozone on leaf net CO sub 2 assimilation of field-grown Vitis vinifera L

    Energy Technology Data Exchange (ETDEWEB)

    Roper, T.R.; Williams, L.E. (Univ. of California, Davis (USA) Kearney Agricultural Center, Parlier, CA (USA))

    1989-12-01

    Mature, field-grown Vitis vinifera L. grapevines grown in open-top chambers were exposed to either charcoal-filtered air or ambient ozone partial pressures throughout the growing season. Individual leaves also were exposed to ozone partial pressures of 0.2, 0.4, or 0.6 micropascals per pascal for 5 hours. No visual ozone damage was found on leaves exposed to any of the treatments. Chronic exposure to ambient O{sub 3} partial pressures reduced net CO{sub 2} assimilation rate (A) between 5 and 13% at various times throughout the season when compared to the filtered treatment. Exposure of leaves to 0.2 micropascals per pascal O{sub 3} for 5 hours had no significant effect on A; however, A was reduced 84% for leaves exposed to 0.6 micropascals per pascal O{sub 3} when compared to the controls after 5 hours. Intercellular CO{sub 2} partial pressure (c{sub i}) was lower for leaves exposed to 0.2 micropascals per pascal O{sub 3} when compared to the controls, while c{sub i} of the leaves treated with 0.6 micropascals per pascal of O{sub 3} increased during the fumigation. The long-term effects of ambient O{sub 3} and short-term exposure to acute levels of O{sub 3} reduced grape leaf photosynthesis due to a reduction in both stomatal and mesophyll conductances.

  12. Oxygen Partial Pressure Is a Rate-Limiting Parameter for Cell Proliferation in 3D Spheroids Grown in Physioxic Culture Condition.

    Science.gov (United States)

    Gomes, Aurélie; Guillaume, Ludivine; Grimes, David Robert; Fehrenbach, Jérôme; Lobjois, Valérie; Ducommun, Bernard

    2016-01-01

    The in situ oxygen partial pressure in normal and tumor tissues is in the range of a few percent. Therefore, when studying cell growth in 3D culture systems, it is essential to consider how the physiological oxygen concentration, rather than the one in the ambient air, influences the proliferation parameters. Here, we investigated the effect of reducing oxygen partial pressure from 21% to 5% on cell proliferation rate and regionalization in a 3D tumor spheroid model. We found that 5% oxygen concentration strongly inhibited spheroid growth, changed the proliferation gradient and reduced the 50% In Depth Proliferation index (IDP50), compared with culture at 21% oxygen. We then modeled the oxygen partial pressure profiles using the experimental data generated by culturing spheroids in physioxic and normoxic conditions. Although hypoxia occurred at similar depth in spheroids grown in the two conditions, oxygen partial pressure was a major rate-limiting factor with a critical effect on cell proliferation rate and regionalization only in spheroids grown in physioxic condition and not in spheroids grown at atmospheric normoxia. Our findings strengthen the need to consider conducting experiment in physioxic conditions (i.e., tissue normoxia) for proper understanding of cancer cell biology and the evaluation of anticancer drugs in 3D culture systems.

  13. Ability of non-invasive intermittent blood pressure monitoring and a continuous non-invasive arterial pressure monitor (CNAP™) to provide new readings in each 1-min interval during elective caesarean section under spinal anaesthesia.

    Science.gov (United States)

    McCarthy, T; Telec, N; Dennis, A; Griffiths, J; Buettner, A

    2012-03-01

    We compared the ability of automated non-invasive intermittent oscillometric blood pressure monitoring with a new device, CNAP(TM) (continuous non-invasive arterial pressure) to provide a new blood pressure reading in each 1-min interval between spinal anaesthesia and delivery during caesarean section. We also compared the accuracy of continuous non-invasive arterial pressure readings with non-invasive blood pressure measurements before spinal anaesthesia. Fifty-nine women participated. The non-invasive and continuous non-invasive monitors displayed new blood pressure readings in a mean of 82% (11%) and 83% (13%) (p = 0.97) of the one-minute intervals between spinal anaesthesia and delivery, respectively. Continuous non-invasive arterial pressure was more likely to fail on two or more consecutive minutes (p=0.001). From the pre-spinal readings, the mean bias, defined as non-invasive-continuous non-invasive arterial pressure, and limits of agreement (±2SD mean bias) for systolic, diastolic and mean blood pressure respectively were +1.3 (±26.0), -2.9 (±21.8) and +2.6 (±20.4) mmHg. The new monitor has disadvantages compared with conventional non-invasive intermittent blood pressure monitoring. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  14. OPPORTUNITIES AND ADVANTAGES OF THE 24-HOUR BLOOD PRESSURE MONITORING IN CHILDREN AS PART OF THE OUTPATIENT EXAMINATION

    Directory of Open Access Journals (Sweden)

    A.E. Pal'tseva

    2009-01-01

    Full Text Available The 24 hour blood pressure monitoring has gone beyond the scope of the scientific research for the last decade and is now more widely used in practical healthcare, including pediatrics to identify changes of pressure both towards hypertension and hypotension. It is obviously advantageous to prove pathologic changes in the blood pressure level, as well as to give an objective evaluation of its intensity and duration. This article is devoted to identification of the diagnostic value for the daily blood pressure monitoring outpatient conditions and development of the optimal monitoring regimes to be used among children.Key words: 24 hour blood pressure monitoring, arterial hypertension, arterial hypotension, vegetovascular dystonia, children.

  15. Speaking one's second language under time pressure: an ERP study on verbal self-monitoring in German-Dutch bilinguals.

    Science.gov (United States)

    Ganushchak, Lesya Y; Schiller, Niels O

    2009-03-01

    This study addresses how verbal self-monitoring and the Error-Related Negativity (ERN) are affected by time pressure when a task is performed in a second language as opposed to performance in the native language. German-Dutch bilinguals were required to perform a phoneme-monitoring task in Dutch with and without a time pressure manipulation. We obtained an ERN following verbal errors that showed an atypical increase in amplitude under time pressure. This finding is taken to suggest that under time pressure participants had more interference from their native language, which in turn led to a greater response conflict and thus enhancement of the amplitude of the ERN. This result demonstrates once more that the ERN is sensitive to psycholinguistic manipulations and suggests that the functioning of the verbal self-monitoring system during speaking is comparable to other performance monitoring, such as action monitoring.

  16. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore

    Directory of Open Access Journals (Sweden)

    Setia S

    2017-07-01

    Full Text Available Sajita Setia,1 Kannan Subramaniam,2 Boon Wee Teo,3 Jam Chin Tay4 1Chief Medical Office, Medical Affairs, Pfizer Pte Ltd, Singapore; 2Global Medical Affairs, Asia Pacific Region, Pfizer Australia, West Ryde, New South Wales, Australia; 3Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; 4Department of General Medicine, Tan Tock Seng Hospital, Singapore Purpose: Out-of-office blood pressure (BP measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM] provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. Materials and methods: A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Results: Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists were included (77% male, 85% aged 31–60 years, and mean 22-year practice. Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and

  17. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore.

    Science.gov (United States)

    Setia, Sajita; Subramaniam, Kannan; Teo, Boon Wee; Tay, Jam Chin

    2017-01-01

    Out-of-office blood pressure (BP) measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM]) provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV) awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists) were included (77% male, 85% aged 31-60 years, and mean 22-year practice). Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians) and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and only 55% said that they had the ability to provide education on HBPM and BPV. Patient inertia, poor patient compliance, lack of medical consultation time, and poor patient access to a BP machine were the most common challenges for implementing out-of-office BP monitoring. Although physicians from Singapore do recommend out-of-office BP measurement to patients with hypertension, this survey identified several important gaps in knowledge and clinical practice.

  18. [Blood pressure monitoring - Status quo and future : A contribution to the personalized medicine].

    Science.gov (United States)

    Engelmann, L; Kunig, S; Kunig, H

    2016-10-01

    Sustainment of life demands that the heart create sufficient pressure to maintain enough flow to keep the body healthy and oxygenated. Blood pressures can be easily measured, while volume measurements required additional invasive procedures. In analogy to volumetrically determined ejection fraction, a pressure ejection fraction EF(P) may be calculated. When standardized to heart rate and body surface area, a new, effective performance metric may be defined. These metrics enable the long-term monitoring of the critically ill patient. When presented in a performance diagram, the metrics contain prognostic implications and enable a real-time evaluation of the efficacy of therapeutic measures. Until now, pressure-related prognostic statements were based on statistical averages, which by definition apply to groups. With this new analytical approach, we have the ability to provide patient-specific therapeutics in an area of medicine that requires individualized treatment. Here, we show preliminary results of applying a mathematical risk analysis to blood pressure metrics to assess therapeutic risk.

  19. Eddy current monitoring of fatigue crack growth in Zr-2.5% Nb pressure tube

    Science.gov (United States)

    Krause, T. W.; Martin, A. E.; Sheppard, R. R.; Schankula, J. J.

    2000-05-01

    Zr-2.5% wt. Nb pressure tubes (PTs) form the core of the heat transport system in CANDU nuclear reactors. These 6 m long, 100 mm diameter tubes are operated at elevated temperatures (nominally 300 °C) and at pressures that produce hoop stresses that are 25% of the ultimate tensile strength of the PT (120 Mpa). Therefore, detection and characterization of flaws in these components becomes crucial for their continued pressure retaining integrity. If a flaw is detected, however, the cost of PT replacement is expensive. Periodic in-service inspection of a flaw that demonstrates no change in flaw characteristics can be used to allow a pressure tube to remain in-service. This requires confidence in the accuracy and reliability of methods used to inter flaw characteristics. Such confidence can only be developed by comparing nondestructive predictions with results from destructive examinations. In this work, eddy current testing was used to monitor the progressive stages of a fatigue crack, grown through pressure cycling from a notch on the inner surface of a PT. Results from a differential lift-off compensated eddy current probe were used to produce sizing estimates of the crack grown between 35% (base of notch) and 74% of the PT wall. A comparison with a destructive examination of the crack demonstrated sensitivity too changes in crack depth accurate to 5% of the tube wall thickness. Such results, combined with similar information obtained from ultrasonics will increase confidence in interpretation of PT inspection data.

  20. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Sang-Hyun; Lilot, Marc; Sidhu, Kulraj S; Rinehart, Joseph; Yu, Zhaoxia; Canales, Cecilia; Cannesson, Maxime

    2014-05-01

    Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were -1.6 ± 12.2 mmHg (95% limits of agreement -25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (-11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (-13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were -1.8 ± 12.4 mmHg (-26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (-10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (-13.1 to 21.0 mmHg) for mean arterial pressure. The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.

  1. Cost-effectiveness of ambulatory blood pressure monitoring in the management of hypertension.

    Science.gov (United States)

    Costa, Diogo; Peixoto Lima, Ricardo

    2017-02-01

    The prevalence of hypertension in Portugal is between 29.1% and 42.2%. International studies show that 13% of individuals have masked hypertension and 13% of diagnoses based on office blood pressure measurements are in fact white coat hypertension. More sensitive and specific blood pressure measuring methods could avoid costs associated with misdiagnosis. The aim of this study was to review the cost-effectiveness of ambulatory blood pressure monitoring (ABPM) compared to other methods in the management of hypertension. We performed a literature search in CMA Infobase, Guidelines Finder, National Guideline Clearinghouse, Bandolier, BMJ Clinical Evidence, the Cochrane Library, DARE, Medline, the Trip Database, SUMSearch and Índex das Revistas Médicas Portuguesas. We researched articles published between January 2005 and August 2015 in Portuguese, English and Spanish, using the MeSH terms "Hypertension", "Blood Pressure Monitoring, Ambulatory" and "Cost-Benefit Analysis" and the Portuguese search terms "Hipertensão", "Monitorização Ambulatorial da Pressão Arterial" and "Análise Custo-Benefício". Levels of evidence and grades of recommendation were attributed according to the Oxford Centre for Evidence-Based Medicine scale. Five hundred and twenty-five articles were identified. We included five original studies and one clinical practice guideline. All of them state that ABPM is the most cost-effective method. Two report better blood pressure control, and a Portuguese study revealed a saving of 23%. The evidence shows that ABPM is cost-effective, avoiding iatrogenic effects and reducing expenditure on treatment (grade of recommendation B). The included studies provide a solid basis, but further evidence of reproducibility is needed in research that is not based mainly on analytical models. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  3. CO(2) partial pressure and calcite saturation in springs - useful data for identifying infiltration areas in mountainous environments.

    Science.gov (United States)

    Hilberg, Sylke; Brandstätter, Jennifer; Glück, Daniel

    2013-04-01

    Mountainous regions such as the Central European Alps host considerable karstified or fractured groundwater bodies, which meet many of the demands concerning drinking water supply, hydropower or agriculture. Alpine hydrogeologists are required to describe the dynamics in fractured aquifers in order to assess potential impacts of human activities on water budget and quality. Delineation of catchment areas by means of stable isotopes and hydrochemical data is a well established method in alpine hydrogeology. To achieve reliable results, time series of (at least) one year and spatial and temporal close-meshed data are necessary. In reality, test sites in mountainous regions are often inaccessible due to the danger of avalanches in winter. The aim of our work was to assess a method based on the processes within the carbonic acid system to delineate infiltration areas by means of single datasets consisting of the main hydrochemical parameters of each spring. In three geologically different mountainous environments we managed to classify the investigated springs into four groups. (1) High PCO2 combined with slight super-saturation in calcite, indicating relatively low infiltration areas. (2) Low PCO2 near atmospheric conditions in combination with calcite saturation, which is indicative of relatively high infiltration areas and a fractured aquifer which is not covered by topsoil layers. (3) High PCO2 in combination with sub-saturation in calcite, representing a shallow aquifer with a significant influence of the topsoil layer. (4) The fourth group of waters is characterized by low PCO2 and sub-saturation in calcite, which is interpreted as evidence for a shallow aquifer without significant influence of any hard rock aquifer or topsoil layer. This study shows that CO2-partial pressure can be an ideal natural tracer to estimate the elevation of infiltration areas, especially in non-karstified fractured groundwater bodies.

  4. Influence of oxygen partial pressure on optical and structural properties of RF sputtered ZnO thin films

    Science.gov (United States)

    Murkute, P.; Saha, S.; Pandey, S. K.; Chatterjee, A.; Datta, D.; Chakrabarti, S.

    2016-02-01

    In this paper we report a detailed investigation of ZnO thin film properties deposited on Si substrate at 400°C using RF sputtering. To reduce oxygen induced vacancies and interstitial defects in samples, variable oxygen flow rate during deposition followed by post growth annealing in oxygen ambient were carried out. Four samples were deposited under constant temperature condition but with variable oxygen partial pressure of 0%, 20%, 50% and 80% in Argon and Oxygen mixture, namely sample S1, S2 , S3 and S4 respectively. Deposited films were further annealed at 700, 800, 900 and 1000°C in oxygen ambient for 10s. Photoluminescence (PL) measurements carried at low temperature (18K) demonstrated near band edge emission peak of ZnO at 3.37eV. Increment in PL intensity was observed with increasing annealing temperature and a particular sample S4 annealed at 900 measured narrowest full width half maxima (FWHM) of ~0.1272eV. Defects peaks observed at lower energies were suppressed with increasing oxygen flow and post growth annealing, indicating improvement in film quality. From HRXRD measurement it was observed S4 sample annealed at 900°C has the highest peak intensity and narrowest FWHM compared to other samples, demonstrating the best crystalline property of annealed film at 900°C. Highest XRD peak intensity measured at 34.53° corresponds to (002) crystal orientation reveals that the films were highly caxis oriented. AFM results show increase in grain size with increasing oxygen flow and annealing temperature which ensures improvement in morphological properties of the film.

  5. Maximizing the Hydrogen Photoproduction Yields in Chlamydomonas Reinhardtii Cultures: The Effect of the H2 Partial Pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kosourov, S. N.; Batyrova, K. A.; Petushkova, E. P.; Tsygankov, A. A.; Ghirardi, M. L.; Seibert, M.

    2012-05-01

    Photoproduction of H{sub 2} gas has been examined in sulfur/phosphorus-deprived Chalmydomonas reinhardtii cultures, placed in photobioreactors (PhBRs) with different gas phase to liquid phase ratios (V{sub g.p.}/V{sub l.p.}). The results demonstrate that an increase in the ratio stimulates H{sub 2} photoproduction activity in both algal suspension cultures and in algae entrapped in thin alginate films. In suspension cultures, a 4x increase (from {approx}0.5 to {approx}2) in V{sub g.p.}/V{sub l.p} results in a 2x increase (from 10.8 to 23.1 mmol l{sup -1} or 264-565 ml l{sup -1}) in the total yield of H{sub 2} gas. Remarkably, 565 ml of H{sub 2} gas per liter of the suspension culture is the highest yield ever reported for a wild-type strain in a time period of less than 190 h. In immobilized algae, where diffusion of H{sub 2} from the medium to the PhBR gas phase is not affected by mixing, the maximum rate and yield of H{sub 2} photoproduction occur in PhBRs with V{sub g.p.}/V{sub l.p} above 7 or in a PhBR with smaller headspace, if the H{sub 2} is effectively removed from the medium by continuous flushing of the headspace with argon. These experiments in combination with studies of the direct inhibitory effect of high H{sub 2} concentrations in the PhBR headspace on H{sub 2} photoproduction activity in algal cultures clearly show that H{sub 2} photoproduction in algae depends significantly on the partial pressure of H{sub 2} (not O{sub 2} as previously thought) in the PhBR gas phase.

  6. Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    Science.gov (United States)

    Wright, J M; Mattu, G S; Perry Jr, T L; Gelferc, M E; Strange, K D; Zorn, A; Chen, Y

    2001-06-01

    To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. Raw pulse wave and cuff pressure data were stored electronically using embedded software in the BPM-100(Beta), during the validation trial. The 391 sets of measurements were separated objectively into two subsets. A subset of 136 measurements was used to develop a new algorithm to enhance the accuracy of the device when reading higher systolic pressures. The larger subset of 255 measurements (three readings for 85 subjects) was used as test data to validate the accuracy of the new algorithm. Differences between the new algorithm BPM-100 and the reference (mean of two observers) were determined and expressed as the mean difference +/- SD, plus the percentage of measurements within 5, 10, and 15 mmHg. The mean difference between the BPM-100 and reference systolic BP was -0.16 +/- 5.13 mmHg, with 73.7% BPM-100 and reference diastolic BP was -1.41 +/- 4.67 mmHg, with 78.4% BPM-100(Beta) and pass the AAMI standard, and 'A' grade BHS protocol. This study illustrates a new method for developing and testing a change in an algorithm for an oscillometric BP monitor utilizing collected and stored electronic data and demonstrates that the new algorithm meets the AAMI standard and BHS protocol.

  7. Miniature Coplanar Implantable Antenna on Thin and Flexible Platform for Fully Wireless Intracranial Pressure Monitoring System

    Directory of Open Access Journals (Sweden)

    M. Waqas A. Khan

    2017-01-01

    Full Text Available Minimally invasive approach to intracranial pressure monitoring is desired for long-term diagnostics. The monitored pressure is transmitted outside the skull through an implant antenna. We present a new miniature (6 mm × 5 mm coplanar implant antenna and its integration on a sensor platform to establish a far-field data link for the sensor readout at distances of 0.5 to 1 meter. The implant antenna was developed using full-wave electromagnetic simulator and measured in a liquid phantom mimicking the dielectric properties of the human head. It achieved impedance reflection coefficient better than −10 dB from 2.38 GHz to 2.54 GHz which covers the targeted industrial, scientific, and medical band. Experiments resulted in an acceptable peak gain of approximately −23 dBi. The implant antenna was submerged in the liquid phantom and interfaced to a 0.5 mW voltage controlled oscillator. To verify the implant antenna performance as a part of the ICP monitoring system, we recorded the radiated signal strength using a spectrum analyzer. Using a half-wavelength dipole as the receiving antenna, we captured approximately −58.7 dBm signal at a distance of 1 m from the implant antenna which is well above for the reader with sensitivity of −80 dBm.

  8. Acceptance and side effects of ambulatory blood pressure monitoring: evaluation of a new technology.

    Science.gov (United States)

    Beltman, F W; Heesen, W F; Smit, A J; May, J F; Lie, K I; Meyboom-de Jong, B

    1996-09-01

    Ambulatory blood pressure (BP) monitoring is probably becoming a clinically useful procedure for the evaluation of hypertensive patients. Previous reports have shown that the devices are safe and serious side effects are rare. Discomfort and inconveniences associated with its use are more frequent. In this study, patient acceptance of ambulatory blood pressure monitoring (ABPM) was compared with acceptance of other diagnostic procedures and their side effects were assessed. Patients were asked to fill in a form and 129 of 166 patients responded. The acceptance was measured with a visual analogue scale which ranged from 'very annoying' on the left to 'not annoying at all' on the right. All forms were collected anonymously. Mean distance (cm) of the visual likert scale was 8.6 to 9.4 for the diagnostic procedures frequently used in routine patient care. Ambulatory BP measurement (ABPM) scored 6.1 cm. Reported side effects (in 27% of patients) were: plan (9%), skin irritation (8%), noisy device (8%), inconvenience with work (3%), haematoma (2%) and other (4%). Reports from the patients on sleep quality were: 23% normal, 61% minor disturbance, 14% had sleep, and 2% did not sleep at all. It can be concluded that ambulatory BP monitoring was the diagnostic procedure with the lowest patient acceptance. Side effects of this new technology were reported by 27% of patients. However, risks are relatively minor. Sleep disturbances were very frequent and was a serious problem for 16% of patients.

  9. A study of partial pressure of arterial carbon dioxide and end-tidal carbon dioxide correlation in intraoperative and postoperative period in neurosurgical patients

    Science.gov (United States)

    Gaur, Pallavi; Harde, Minal; Gujjar, Pinakin; Deosarkar, Devanand; Bhadade, Rakesh

    2017-01-01

    Background and Aim: Monitoring carbon dioxide (CO2) is of utmost importance in neurosurgical patients. It is measured by partial pressure of arterial CO2 (PaCO2) and end-tidal CO2 (ETCO2). We aimed to study the correlation between PaCO2 and ETCO2 in neurosurgical patients in the intraoperative and postoperative period on mechanical ventilation in Postanesthesia Care Unit (PACU). Methodology: This was prospective observational study done at tertiary care teaching public hospital over a period of 1 year. We studied 30 patients undergoing elective craniotomy intraoperatively and in the postoperative period on mechanical ventilation for 24 h. Serial measurement of ETCO2 and PaCO2 at baseline, hourly intraoperatively and every 6 hourly in the PACU were studied. Data analysis was done using SPSS software version 20. Results: The mean PaCO2–ETCO2 gradient intraoperatively over 4 h is 3.331 ± 2.856 and postoperatively over 24 h is 2.779 ± 2.932 and lies in 95% confidence interval. There was statistically significant correlation between PaCO2 and ETCO2 intraoperatively baseline, 1 h, 2 h, 3 h, and 4 h with Pearson's correlation coefficients of 0.799, 0.522, 0582, 0.439, and 0.547, respectively (P < 0.05). In PACU at baseline, 6 h, 12 h, 18 h, and 24 h Pearson's correlation coefficients were. 534, −0.032, 0.522, 0.242, 0.592, and 0.547, respectively, which are highly significant at three instances (P < 0.01). Conclusion: ETCO2 correlates PaCO2 with acceptable accuracy in neurosurgical patients in the intraoperative and postoperative period on mechanical ventilation in Intensive Care Unit. Thus, continuous and noninvasive ETCO2 can be used as a reliable guide to estimate arterial PCO2 during neurosurgical procedures and in PACU. PMID:28761526

  10. Moisture Migration in an Oil-Paper Insulation System in Relation to Online Partial Discharge Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Wojciech Sikorski

    2016-12-01

    Full Text Available Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats to proper operation of the transformer, e.g., ignition of partial discharges (PDs. Due to the varying temperature of the insulation system during the unit’s normal operation, a dynamic change (migration of water takes place, precipitating the oil-paper system from a state of hydrodynamic equilibrium. This causes the PDs to be variable in time, and they may intensify or extinguish. Studies on model objects have been conducted to determine the conditions (temperature, humidity, time that will have an impact on the ignition and intensity of the observed phenomenon of PDs. The conclusions of this study will have a practical application in the evaluation of measurements conducted in the field, especially in relation to the registration of an online PD monitoring system.

  11. Ambulatory Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension.

    Science.gov (United States)

    Islam, Md Shahidul

    2016-12-16

    Clinicians should take initiatives to establish ambulatory blood pressure monitoring (ABPM) services in their own practice, or to ensure that they have access to such services elsewhere. Whenever possible, ABPM should be performed in suitable cases, where it is likely to deliver clinically useful information for making a correct diagnosis, or for tailoring the anti-hypertensive treatment regimen for each individual patient. ABPM is clinically useful, among others, for identifying people with "masked normotension", "masked hypertension", "sleep-time hypertension", and "reduced decline of sleep-time blood pressure". This review briefly outlines the rationales for the use of ABPM, interpretations of the ABPM-derived parameters, and the advantages of ABPM in decision making in the management of hypertension.

  12. A pressure-sensitive carbon black cement composite for traffic monitoring

    KAUST Repository

    Monteiro, A.O.

    2017-08-17

    Recent advances in nanotechnology have guided the development of a new generation of multifunctional construction materials. An example of this are cement-based composites, some of which can be used not just to pave roads but also to monitor them. A cement composite, integrating a carbon black (CB) filler, was used as a piezoresistive sensor to identify different cyclic compressive loadings, at temperatures ranging from 15°C to 45°C. The mechanical essays were performed under realistic conditions using 600cm3 specimens and uniaxial loads typical of automobile traffic. A linear and reversible pressure-sensing performance was found with gauge factors ranging from 40 to 60. Overall, these results show that CB/cement composites can act as stress-sensitive materials for traffic monitoring.

  13. Collaborative Processing of Wearable and Ambient Sensor System for Blood Pressure Monitoring

    Science.gov (United States)

    Nakamura, Masayuki; Nakamura, Jiro; Lopez, Guillaume; Shuzo, Masaki; Yamada, Ichiro

    2011-01-01

    This paper describes wireless wearable and ambient sensors that cooperate to monitor a person’s vital signs such as heart rate and blood pressure during daily activities. Each wearable sensor is attached on different parts of the body. The wearable sensors require a high sampling rate and time synchronization to provide a precise analysis of the received signals. The trigger signal for synchronization is provided by the ambient sensors, which detect the user’s presence. The Bluetooth and IEEE 802.15.4 wireless technologies are used for real-time sensing and time synchronization. Thus, this wearable health-monitoring sensor response is closely related to the context in which it is being used. Experimental results indicate that the system simultaneously provides information about the user’s location and vital signs, and the synchronized wearable sensors successfully measures vital signs with a 1 ms resolution. PMID:22163984

  14. Collaborative Processing of Wearable and Ambient Sensor System for Blood Pressure Monitoring

    Directory of Open Access Journals (Sweden)

    Ichiro Yamada

    2011-06-01

    Full Text Available This paper describes wireless wearable and ambient sensors that cooperate to monitor a person’s vital signs such as heart rate and blood pressure during daily activities. Each wearable sensor is attached on different parts of the body. The wearable sensors require a high sampling rate and time synchronization to provide a precise analysis of the received signals. The trigger signal for synchronization is provided by the ambient sensors, which detect the user’s presence. The Bluetooth and IEEE 802.15.4 wireless technologies are used for real-time sensing and time synchronization. Thus, this wearable health-monitoring sensor response is closely related to the context in which it is being used. Experimental results indicate that the system simultaneously provides information about the user’s location and vital signs, and the synchronized wearable sensors successfully measures vital signs with a 1 ms resolution.

  15. Real-time combustion control and diagnostics sensor-pressure oscillation monitor

    Science.gov (United States)

    Chorpening, Benjamin T.; Thornton, Jimmy; Huckaby, E. David; Richards, George A.

    2009-07-14

    An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

  16. SMART MONITORING AND DECISION MAKING FOR REGULATING ANNULUS BOTTOM HOLE PRESSURE WHILE DRILLING OIL WELLS

    Directory of Open Access Journals (Sweden)

    M. P. Vega

    Full Text Available Abstract Real time measurements and development of sensor technology are research issues associated with robustness and safety during oil well drilling operations, making feasible the diagnosis of problems and the development of a regulatory strategy. The major objective of this paper is to use an experimental plant and also field data, collected from a basin operation, offshore Brazil, for implementing smart monitoring and decision making, in order to assure drilling inside operational window, despite the commonly observed disturbances that produce fluctuations in the well annulus bottom hole pressure. Using real time measurements, the performance of a continuous automated drilling unit is analyzed under a scenario of varying levels of rate of penetration; aiming pressure set point tracking (inside the operational drilling window and also rejecting kick, a phenomenon that occurs when the annulus bottom hole pressure is inferior to the porous pressure, producing the migration of reservoir fluids into the annulus region. Finally, an empirical model was built, using real experimental data from offshore Brazil basins, enabling diagnosing and regulating a real drilling site by employing classic and advanced control strategies.

  17. Invasive intracranial arterial pressure monitoring during endovascular cerebral aneurysms embolization for cerebral perfusion evaluation.

    Science.gov (United States)

    Netlyukh, Andriy M; Shevaga, Volodymyr M; Yakovenko, Leonid M; Payenok, Angelika V; Salo, Victor M; Kobyletskiy, Oleg Ja

    2015-01-01

    The purpose of the study was to define a method of estimation of cerebral blood flow by a determination of parameters of the hemodynamics during neuroendovascular procedures. Materials and Methods. Extracranial and intracranial mean arterial pressure (MAP) was invasively monitored with the help of a transducing system during an endovascular coiling procedure in 19 patients. The measurements were performed at the tip of the guiding catheter and microcatheter placed into internal carotid artery (ICA) C1 segments and of the microcatheter placed into C4 ICA segments, at different stages of the aneurysm repair. Results. As measured, the diameter of the ICA in the C1 and C4 segments did not differ substantially. MAP in the ICA was determined to be 91.2 ± 9.6 mmHg in the skull cavity, and 102.4 ± 6.3 mmHg outside of the skull cavity, with an average difference of 9.2 ± 3.0 mmHg. Conclusion. The difference in MAP, as measured in the ICA outside and inside the skull cavity, was ascribed to the influence of intracranial pressure. Further investigation is required to check the accuracy of invasive intra-arterial pressure recording for an objective and direct measurement of the cerebral perfusion in reference to the intracranial pressure level.

  18. Real-time combustion control and diagnostics sensor-pressure oscillation monitor

    Science.gov (United States)

    Chorpening, Benjamin T.; Thornton, Jimmy; Huckaby, E. David; Richards, George A.

    2009-07-14

    An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

  19. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    Science.gov (United States)

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  20. Assessment of the usability of a digital learning technology prototype for monitoring intracranial pressure

    Directory of Open Access Journals (Sweden)

    Lilian Regina de Carvalho

    Full Text Available ABSTRACT Objective: to assess the usability of a digital learning technology prototype as a new method for minimally invasive monitoring of intracranial pressure. Method: descriptive study using a quantitative approach on assessing the usability of a prototype based on Nielsen's ten heuristics. Four experts in the area of Human-Computer interaction participated in the study. Results: the evaluation delivered eight violated heuristics and 31 usability problems in the 32 screens of the prototype. Conclusion: the suggestions of the evaluators were critical for developing an intuitive, user-friendly interface and will be included in the final version of the digital learning technology.

  1. Development of a nuclear technique for monitoring water levels in pressurized vehicles

    Science.gov (United States)

    Singh, J. J.; Davis, W. T.; Mall, G. H.

    1983-01-01

    A new technique for monitoring water levels in pressurized stainless steel cylinders was developed. It is based on differences in attenuation coefficients of water and air for Cs137 (662 keV) gamma rays. Experimentally observed gamma ray counting rates with and without water in model reservoir cylinder were compared with corresponding calculated values for two different gamma ray detection theshold energies. Calculated values include the effects of multiple scattering and attendant gamma ray energy reductions. The agreement between the measured and calculated values is reasonably good. Computer programs for calculating angular and spectral distributions of scattered radition in various media are included.

  2. NASA Prototype All Composite Tank Cryogenic Pressure Tests to Failure with Structural Health Monitoring

    Science.gov (United States)

    Werlink, Rudolph J.; Pena, Francisco

    2015-01-01

    This Paper will describe the results of pressurization to failure of 100 gallon composite tanks using liquid nitrogen. Advanced methods of health monitoring will be compared as will the experimental data to a finite element model. The testing is wholly under NASA including unique PZT (Lead Zirconate Titanate) based active vibration technology. Other technologies include fiber optics strain based systems including NASA AFRC technology, Acoustic Emission, Acellent smart sensor, this work is expected to lead to a practical in-Sutu system for composite tanks.

  3. Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects.

    Science.gov (United States)

    Wu, Jun; He, Wei; Chen, Wei-Min; Zhu, Lian

    2013-01-01

    The real-time monitoring of intracranial pressure (ICP) is very important for craniocerebrally critically ill patients, but it is very difficult to realize long-time monitoring for the traditional invasive method, which very easily infects patients. Many noninvasive methods have emerged, but these have not been able to monitor ICP for long periods in real time, and they are not ready for clinical application. In order to realize long-time, online, real-time, noninvasive monitoring for ICP, a new method based on acoustoelasticity of ultrasound is herein proposed. Experimental models were devised to research the new method for experiment and simulation. Polymethyl methacrylate and hydrogel were adopted for the experiment, and their mechanical properties were very close to the real brain. A numerical solution for acoustoelasticity theory was acquired by simulating calculation based on a finite-element method. This was compared to the experimental value. The results showed a consistent match between theoretical solution and experimental value, with maximum error at most 5%. Thus, the effectiveness of the new method was verified. Theoretical and practical foundation is provided for this new method, and it could be used for animal experimentation or clinical testing in further research.

  4. Blood viscosity monitoring during cardiopulmonary bypass based on pressure-flow characteristics of a Newtonian fluid.

    Science.gov (United States)

    Okahara, Shigeyuki; Zu Soh; Takahashi, Shinya; Sueda, Taijiro; Tsuji, Toshio

    2016-08-01

    We proposed a blood viscosity estimation method based on pressure-flow characteristics of oxygenators used during cardiopulmonary bypass (CPB) in a previous study that showed the estimated viscosity to correlate well with the measured viscosity. However, the determination of the parameters included in the method required the use of blood, thereby leading to high cost of calibration. Therefore, in this study we propose a new method to monitor blood viscosity, which approximates the pressure-flow characteristics of blood considered as a non-Newtonian fluid with characteristics of a Newtonian fluid by using the parameters derived from glycerin solution to enable ease of acquisition. Because parameters used in the estimation method are based on fluid types, bovine blood parameters were used to calculate estimated viscosity (ηe), and glycerin parameters were used to estimate deemed viscosity (ηdeem). Three samples of whole bovine blood with different hematocrit levels (21.8%, 31.0%, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37 °C to 27 °C, the oxygenator mean inlet pressure and outlet pressure were recorded for flows of 2 L/min and 4 L/min, and the viscosity was estimated. The value of deemed viscosity calculated with the glycerin parameters was lower than estimated viscosity calculated with bovine blood parameters by 20-33% at 21.8% hematocrit, 12-27% at 31.0% hematocrit, and 10-15% at 39.8% hematocrit. Furthermore, deemed viscosity was lower than estimated viscosity by 10-30% at 2 L/min and 30-40% at 4 L/min. Nevertheless, estimated and deemed viscosities varied with a similar slope. Therefore, this shows that deemed viscosity achieved using glycerin parameters may be capable of successfully monitoring relative viscosity changes of blood in a perfusing oxygenator.

  5. Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects

    Directory of Open Access Journals (Sweden)

    Wu J

    2013-08-01

    Full Text Available Jun Wu1, Wei He2, Wei-min Chen1, Lian Zhu21Key Laboratory of Optoelectronic Technology and Systems, 2State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, People’s Republic of ChinaAbstract: The real-time monitoring of intracranial pressure (ICP is very important for craniocerebrally critically ill patients, but it is very difficult to realize long-time monitoring for the traditional invasive method, which very easily infects patients. Many noninvasive methods have emerged, but these have not been able to monitor ICP for long periods in real time, and they are not ready for clinical application. In order to realize long-time, online, real-time, noninvasive monitoring for ICP, a new method based on acoustoelasticity of ultrasound is herein proposed. Experimental models were devised to research the new method for experiment and simulation. Polymethyl methacrylate and hydrogel were adopted for the experiment, and their mechanical properties were very close to the real brain. A numerical solution for acoustoelasticity theory was acquired by simulating calculation based on a finite-element method. This was compared to the experimental value. The results showed a consistent match between theoretical solution and experimental value, with maximum error at most 5%. Thus, the effectiveness of the new method was verified. Theoretical and practical foundation is provided for this new method, and it could be used for animal experimentation or clinical testing in further research.Keywords: medical instruments, noninvasive, intracranial pressure, ultrasonic, acoustoelasticity, biomechanics

  6. Safety profile and probe placement accuracy of intraspinal pressure monitoring for traumatic spinal cord injury: Injured Spinal Cord Pressure Evaluation study.

    Science.gov (United States)

    Phang, Isaac; Zoumprouli, Argyro; Saadoun, Samira; Papadopoulos, Marios C

    2016-09-01

    OBJECTIVE A novel technique for monitoring intraspinal pressure and spinal cord perfusion pressure in patients with traumatic spinal cord injury was recently described. This is analogous to monitoring intracranial pressure and cerebral perfusion pressure in patients with traumatic brain injury. Because intraspinal pressure monitoring is a new technique, its safety profile and impact on early patient care and long-term outcome after traumatic spinal cord injury are unknown. The object of this study is to review all patients who had intraspinal pressure monitoring to date at the authors' institution in order to define the accuracy of intraspinal pressure probe placement and the safety of the technique. METHODS At the end of surgery to fix spinal fractures, a pressure probe was inserted intradurally to monitor intraspinal pressure at the injury site. Postoperatively, CT scanning was performed within 48 hours and MRI at 2 weeks and 6 months. Neurointensive care management and complications were reviewed. The American Spinal Injury Association Impairment Scale (AIS) grade was determined on admission and at 2 to 4 weeks and 12 to 18 months postoperation. RESULTS To date, 42 patients with severe traumatic spinal cord injuries (AIS Grades A-C) had undergone intraspinal pressure monitoring. Monitoring started within 72 hours of injury and continued for up to a week. Based on postoperative CT and MRI, the probe position was acceptable in all patients, i.e., the probe was located at the site of maximum spinal cord swelling. Complications were probe displacement in 1 of 42 patients (2.4%), CSF leakage that required wound resuturing in 3 of 42 patients (7.1%), and asymptomatic pseudomeningocele that was diagnosed in 8 of 42 patients (19.0%). Pseudomeningocele was diagnosed on MRI and resolved within 6 months in all patients. Based on the MRI and neurological examination results, there were no serious probe-related complications such as meningitis, wound infection, hematoma

  7. The development and validation of a digital peak respiratory pressure monitor and its characteristics in healthy human subjects.

    Science.gov (United States)

    Maruthy, K N; Vaz, M

    1999-04-01

    A digital peak respiratory pressure (DPRP) monitor for determining maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP) was developed using a pressure transducer and an analog to digital converter. It was calibrated using a mercury manometer. Human studies were conducted in healthy young adults in order to determine within-subject and inter-individual variability, as well as diurnal variations and gender differences in maximal respiratory pressures. The calibration studies for the instrument indicated that the instrument recorded accurate pressures, with little temporal drift. Within-subject variability was generally low while inter-individual variability was higher and significant. Gender differences were similar to those recorded in literature for other racial groups. The DPRP monitor described is inexpensive, accurate and portable, making it ideal for use at the patient's bedside.

  8. Long-term pressure monitoring with arterial applanation tonometry : a non-invasive alternative during clinical intervention?

    NARCIS (Netherlands)

    Matthys, Koen S; Kalmar, Alain F; Struys, Michel M R F; Mortier, Eric P; Avolio, Alberto P; Segers, Patrick; Verdonck, Pascal R

    2008-01-01

    Arterial tonometry is a non-invasive technique for continuous registration of arterial pressure waveforms. This study aims to assess tonometric blood pressure recording (TBP) as an alternative for invasive long-term bedside monitoring. A prospective study was set up where patients undergoing neurosu

  9. Biomethanation Of Syngas Using Anaerobic Sludge: Shift In The Catabolic Routes With The CO Partial Pressure Increase

    Directory of Open Access Journals (Sweden)

    Silvia Sancho-Navarro

    2016-08-01

    Full Text Available Syngas generated by thermal gasification of biomass or coal can be steam reformed and purified into methane, which could be used locally for energy needs, or re-injected in the natural gas grid. As an alternative to chemical catalysis, the main components of the syngas (CO, CO2, and H2 can be used as substrates by a wide range of microorganisms, to be converted into gas biofuels, including methane. This study evaluates the carboxydotrophic (CO-consuming methanogenic potential present in an anaerobic sludge from an upflow anaerobic sludge bed (UASB reactor treating waste water, and elucidates the CO conversion routes to methane at 35±3˚C. Kinetic activity tests under CO at partial pressures (pCO varying from 0.1 to 1.5 atm (0.09-1.31 mmol/L in the liquid phase showed a significant carboxydotrophic activity potential for growing conditions on CO alone. A maximum methanogenic activity of 1 mmol CH4 per g of volatile suspended solid and per day was achieved at 0.2 atm of CO (0.17 mmol/L, and then the rate decreased with the amount of CO supplied. The intermediary metabolites such as acetate, H2 and propionate started to accumulate at higher CO concentrations. Inhibition experiments with 2-bromoethanesulfonic acid (BES, fluoroacetate, and vancomycin showed that in a mixed culture CO was converted mainly to acetate by acetogenic bacteria, which was further transformed to methane by acetoclastic methanogens, while direct methanogenic CO conversion was negligible. Methanogenesis was totally blocked at high pCO in the bottles (≥ 1 atm. However it was possible to achieve higher methanogenic potential under a 100% CO atmosphere after acclimation of the sludge to CO. This adaptation to high CO concentrations led to a shift in the archaeal population, then dominated by hydrogen-utilizing methanogens, which were able to take over acetoclastic methanogens, while syntrophic acetate oxidizing (SAO bacteria oxidized acetate into CO2 and H2. The disaggregation

  10. Response of the endophytic diazotroph Gluconacetobacter diazotrophicus on solid media to changes in atmospheric partial O(2) pressure.

    Science.gov (United States)

    Pan, B; Vessey, J K

    2001-10-01

    Gluconacetobacter diazotrophicus is an N(2)-fixing endophyte isolated from sugarcane. G. diazotrophicus was grown on solid medium at atmospheric partial O(2) pressures (pO(2)) of 10, 20, and 30 kPa for 5 to 6 days. Using a flowthrough gas exchange system, nitrogenase activity and respiration rate were then measured at a range of atmospheric pO(2) (5 to 60 kPa). Nitrogenase activity was measured by H(2) evolution in N(2)-O(2) and in Ar-O(2), and respiration rate was measured by CO(2) evolution in N(2)-O(2). To validate the use of H(2) production as an assay for nitrogenase activity, a non-N(2)-fixing (Nif(-)) mutant of G. diazotrophicus was tested and found to have a low rate of uptake hydrogenase (Hup(+)) activity (0.016 +/- 0.009 micromol of H(2) 10(10) cells(-1) h(-1)) when incubated in an atmosphere enriched in H(2). However, Hup(+) activity was not detectable under the normal assay conditions used in our experiments. G. diazotrophicus fixed nitrogen at all atmospheric pO(2) tested. However, when the assay atmospheric pO(2) was below the level at which the colonies had been grown, nitrogenase activity was decreased. Optimal atmospheric pO(2) for nitrogenase activity was 0 to 20 kPa above the pO(2) at which the bacteria had been grown. As atmospheric pO(2) was increased in 10-kPa steps to the highest levels (40 to 60 kPa), nitrogenase activity decreased in a stepwise manner. Despite the decrease in nitrogenase activity as atmospheric pO(2) was increased, respiration rate increased marginally. A large single-step increase in atmospheric pO(2) from 20 to 60 kPa caused a rapid 84% decrease in nitrogenase activity. However, upon returning to 20 kPa of O(2), 80% of nitrogenase activity was recovered within 10 min, indicating a "switch-off/switch-on" O(2) protection mechanism of nitrogenase activity. Our study demonstrates that colonies of G. diazotrophicus can fix N(2) at a wide range of atmospheric pO(2) and can adapt to maintain nitrogenase activity in response to

  11. Biomethanation of Syngas Using Anaerobic Sludge: Shift in the Catabolic Routes with the CO Partial Pressure Increase

    Science.gov (United States)

    Sancho Navarro, Silvia; Cimpoia, Ruxandra; Bruant, Guillaume; Guiot, Serge R.

    2016-01-01

    Syngas generated by thermal gasification of biomass or coal can be steam reformed and purified into methane, which could be used locally for energy needs, or re-injected in the natural gas grid. As an alternative to chemical catalysis, the main components of the syngas (CO, CO2, and H2) can be used as substrates by a wide range of microorganisms, to be converted into gas biofuels, including methane. This study evaluates the carboxydotrophic (CO-consuming) methanogenic potential present in an anaerobic sludge from an upflow anaerobic sludge bed (UASB) reactor treating waste water, and elucidates the CO conversion routes to methane at 35 ± 3°C. Kinetic activity tests under CO at partial pressures (pCO) varying from 0.1 to 1.5 atm (0.09–1.31 mmol/L in the liquid phase) showed a significant carboxydotrophic activity potential for growing conditions on CO alone. A maximum methanogenic activity of 1 mmol CH4 per g of volatile suspended solid and per day was achieved at 0.2 atm of CO (0.17 mmol/L), and then the rate decreased with the amount of CO supplied. The intermediary metabolites such as acetate, H2, and propionate started to accumulate at higher CO concentrations. Inhibition experiments with 2-bromoethanesulfonic acid (BES), fluoroacetate, and vancomycin showed that in a mixed culture CO was converted mainly to acetate by acetogenic bacteria, which was further transformed to methane by acetoclastic methanogens, while direct methanogenic CO conversion was negligible. Methanogenesis was totally blocked at high pCO in the bottles (≥1 atm). However it was possible to achieve higher methanogenic potential under a 100% CO atmosphere after acclimation of the sludge to CO. This adaptation to high CO concentrations led to a shift in the archaeal population, then dominated by hydrogen-utilizing methanogens, which were able to take over acetoclastic methanogens, while syntrophic acetate oxidizing (SAO) bacteria oxidized acetate into CO2 and H2. The disaggregation of the

  12. Biomethanation of Syngas Using Anaerobic Sludge: Shift in the Catabolic Routes with the CO Partial Pressure Increase.

    Science.gov (United States)

    Sancho Navarro, Silvia; Cimpoia, Ruxandra; Bruant, Guillaume; Guiot, Serge R

    2016-01-01

    Syngas generated by thermal gasification of biomass or coal can be steam reformed and purified into methane, which could be used locally for energy needs, or re-injected in the natural gas grid. As an alternative to chemical catalysis, the main components of the syngas (CO, CO2, and H2) can be used as substrates by a wide range of microorganisms, to be converted into gas biofuels, including methane. This study evaluates the carboxydotrophic (CO-consuming) methanogenic potential present in an anaerobic sludge from an upflow anaerobic sludge bed (UASB) reactor treating waste water, and elucidates the CO conversion routes to methane at 35 ± 3°C. Kinetic activity tests under CO at partial pressures (pCO) varying from 0.1 to 1.5 atm (0.09-1.31 mmol/L in the liquid phase) showed a significant carboxydotrophic activity potential for growing conditions on CO alone. A maximum methanogenic activity of 1 mmol CH4 per g of volatile suspended solid and per day was achieved at 0.2 atm of CO (0.17 mmol/L), and then the rate decreased with the amount of CO supplied. The intermediary metabolites such as acetate, H2, and propionate started to accumulate at higher CO concentrations. Inhibition experiments with 2-bromoethanesulfonic acid (BES), fluoroacetate, and vancomycin showed that in a mixed culture CO was converted mainly to acetate by acetogenic bacteria, which was further transformed to methane by acetoclastic methanogens, while direct methanogenic CO conversion was negligible. Methanogenesis was totally blocked at high pCO in the bottles (≥1 atm). However it was possible to achieve higher methanogenic potential under a 100% CO atmosphere after acclimation of the sludge to CO. This adaptation to high CO concentrations led to a shift in the archaeal population, then dominated by hydrogen-utilizing methanogens, which were able to take over acetoclastic methanogens, while syntrophic acetate oxidizing (SAO) bacteria oxidized acetate into CO2 and H2. The disaggregation of the

  13. Early detection and treatment of myocardial ischaemia after operation using continual ambulatory arterial pressure monitoring and ECG ST segment analysis.

    Science.gov (United States)

    Edwards, N D; Troy, G; Yeo, W; Jackson, P; Reilly, C S

    1995-10-01

    We report a case in which the use of continual ambulatory arterial pressure monitoring and ECG ST-segment analysis allowed early detection and treatment of myocardial ischaemia in the postoperative period. We believe that this case illustrates the potential value of ambulatory monitoring in the early postoperative period in high-risk patients.

  14. A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

    Science.gov (United States)

    Hager, Helmut; Mandadi, Goutham; Pulley, Debra; Eagon, J Chris; Mascha, Edward; Nutter, Benjamin; Kurz, Andrea

    2009-06-01

    In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese, wrist morphology remains relatively unchanged. We thus assessed the degree to which blood pressure measurements with the Vasotrac on the wrist and cuff measurements agree with invasive arterial blood pressure monitoring. We evaluated 22 morbidly obese patients undergoing bariatric surgery lasting 3.8+/-1.1 h. Intraoperative blood pressure was simultaneously measured using the Vasotrac mounted on one wrist; an arterial catheter was inserted in the opposite radial artery, and an oscillometric cuff was positioned on the upper arm. Preoperative patient comfort was evaluated on a scale from 1 to 10, with 10 being most uncomfortable, just after the first oscillometric cuff inflation. Values from the Vasotrac and arterial catheter were recorded at 5-s intervals. Bias, precision, and clinically acceptable agreement were calculated between the two continuous monitoring devices and between the arterial catheter and the cuff measurements, with the arterial catheter providing the reference value. The patients' age was 44.3+/-9.5 years (mean+/-SD), body mass index was 66.7+/-13.8 kg/m2, and arm circumference was 48.6+/-7.5 cm. Patients found the Vasotrac more comfortable than the oscillometric device [1.7+/-1.8 vs 5.3+/-0.5 (P=0.009)]. A total of 40,411 pairs of values from the Vasotrac and arterial catheter were recorded. Lin's concordance correlation coefficient (95% CI) for mean arterial blood pressure measured between the arterial line and the Vasotrac was 0.74 (0.67, 0.82). The bias (mean error) was -0.25 mmHg; however, the Bland-Altman limits where 95% of individual pressure differences are

  15. Simultaneous visualization of oxygen partial pressure, current density, and water droplets in serpentine fuel cell during power generation for understanding reaction distributions

    Science.gov (United States)

    Takanohashi, Kazuhiro; Suga, Takeo; Uchida, Makoto; Ueda, Toshihide; Nagumo, Yuzo; Inukai, Junji; Nishide, Hiroyuki; Watanabe, Masahiro

    2017-03-01

    Understanding the reaction distributions inside a polymer electrolyte fuel cell (PEFC) is essential for the higher performance and durability. We have developed a new see-through cell and visualized the distributions of oxygen partial pressure and current density inside a running PEFC at the temperature of 40 and 80 °C and the relative humidity of 53%. The oxygen utilization was changed from 0% to 80% by changing the current density. At higher oxygen utilizations, the current density was higher and therefore the water generation. Generated water droplets in the flow channel were also visualized, allowing for the simultaneous visualization of the distribution of the oxygen partial pressure, current density, and water droplets. By combining the observations of all three parameters, the reactions inside a membrane-electrode assembly were discussed.

  16. Extended x-ray absorption fine structure measurements on radio frequency magnetron sputtered HfO2 thin films deposited with different oxygen partial pressures.

    Science.gov (United States)

    Maidul Haque, S; Nayak, C; Bhattacharyya, Dibyendu; Jha, S N; Sahoo, N K

    2016-03-20

    Two sets of HfO2 thin film have been deposited by the radio frequency magnetron sputtering technique at various oxygen partial pressures, one set without any substrate bias and another set with a 50 W pulsed dc substrate bias. The films have been characterized by extended x-ray absorption fine structure (EXAFS) measurements at the Hf L3 edge, and the structural information obtained from analysis of the EXAFS data has been used to explain the macroscopic behavior of the refractive index obtained from spectroscopic ellipsometry measurements. It has been observed that the variation of refractive index with oxygen partial pressure depends on the Hf-Hf bond length for the set of films deposited without substrate bias, while for the other set of films deposited with pulsed dc substrate bias, it depends on the oxygen coordination of the nearest neighbor shell surrounding Hf sites.

  17. A flowing liquid test system for assessing the linearity and time-response of rapid fibre optic oxygen partial pressure sensors.

    Science.gov (United States)

    Chen, R; Hahn, C E W; Farmery, A D

    2012-08-15

    The development of a methodology for testing the time response, linearity and performance characteristics of ultra fast fibre optic oxygen sensors in the liquid phase is presented. Two standard medical paediatric oxygenators are arranged to provide two independent extracorporeal circuits. Flow from either circuit can be diverted over the sensor under test by means of a system of rapid cross-over solenoid valves exposing the sensor to an abrupt change in oxygen partial pressure, P O2. The system is also capable of testing the oxygen sensor responses to changes in temperature, carbon dioxide partial pressure P CO2 and pH in situ. Results are presented for a miniature fibre optic oxygen sensor constructed in-house with a response time ≈ 50 ms and a commercial fibre optic sensor (Ocean Optics Foxy), when tested in flowing saline and stored blood.

  18. Impact of antihypertensive combination and monotreatments on blood pressure variability: assessment by old and new indices. Data from a large ambulatory blood pressure monitoring database.

    LENUS (Irish Health Repository)

    Parati, Gianfranco

    2014-06-01

    High 24-h ambulatory blood pressure (ABP) variability is associated with poor cardiovascular outcomes. We analysed a large ABP monitoring database containing data from hypertensive patients treated with telmisartan\\/amlodipine combination or various monotherapies with the aim of quantifying the 24-h distribution of blood pressure (BP) reduction by treatment through the smoothness index and of developing and testing a new treatment-on-variability index (TOVI) to quantify the effects of treatment on both mean BP and BP variability.

  19. Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor

    Directory of Open Access Journals (Sweden)

    Jang-Ho Park

    2015-09-01

    Full Text Available In this study, we developed a novel heart rate (HR monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW into electrical current, and the circuit module enhances the EPW and suppresses noise. A real-time algorithm embedded in the circuit module performs morphological conversions to make the EPW more distinct and knowledge-based rules are used to detect EPW peaks. In a clinical experiment conducted using a reference electrocardiogram (ECG device, EPW and ECG were concurrently recorded from 58 healthy subjects. The EPW intervals between successive peaks and their corresponding ECG intervals were then compared to each other. Promising results were obtained from the samples, specifically, a sensitivity of 97.25%, positive predictive value of 97.17%, and mean absolute difference of 0.62. Thus, highly accurate HR was obtained from in-ear pressure variance. Consequently, we believe that our proposed approach could be used to monitor vital signs and also utilized in diverse applications in the near future.

  20. Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor.

    Science.gov (United States)

    Park, Jang-Ho; Jang, Dae-Geun; Park, Jung Wook; Youm, Se-Kyoung

    2015-09-16

    In this study, we developed a novel heart rate (HR) monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW) into electrical current, and the circuit module enhances the EPW and suppresses noise. A real-time algorithm embedded in the circuit module performs morphological conversions to make the EPW more distinct and knowledge-based rules are used to detect EPW peaks. In a clinical experiment conducted using a reference electrocardiogram (ECG) device, EPW and ECG were concurrently recorded from 58 healthy subjects. The EPW intervals between successive peaks and their corresponding ECG intervals were then compared to each other. Promising results were obtained from the samples, specifically, a sensitivity of 97.25%, positive predictive value of 97.17%, and mean absolute difference of 0.62. Thus, highly accurate HR was obtained from in-ear pressure variance. Consequently, we believe that our proposed approach could be used to monitor vital signs and also utilized in diverse applications in the near future.

  1. Ambulatory blood pressure monitoring and structural changes in carotid arteries in normotensive workers occupationally exposed to lead.

    Science.gov (United States)

    Poreba, Rafał; Poreba, Małgorzata; Gać, Paweł; Andrzejak, Ryszard

    2011-09-01

    Occupational exposure to lead may cause an increase in blood pressure. The aim of the study was to estimate the effect of occupational exposure to lead on selected parameters of ambulatory blood pressure monitoring (ABPM) and structural changes in carotid arteries. The study included 33 normotensive men occupationally exposed to lead and 39 unexposed men employed in administration of the foundry. All of the men underwent 24-hour ambulatory blood pressure monitoring and high-resolution B-mode ultrasonography to determine intima-media thickness (IMT). The group of men occupationally exposed to lead manifested significantly higher mean systolic blood pressure (MSBP), mean diastolic blood pressure (MDBP), mean blood pressure (MBP), pulse pressure (PP), variability of diastolic blood pressure (VDBP), and IMT than the unexposed group. The studied groups did not differ in mean values of variability of systolic blood pressure (VSBP). As compared to the unexposed group, in men exposed to lead, atherosclerotic plaques were significantly more common. In the group of persons exposed to lead the Pearson's correlation coefficient analysis revealed significant linear positive correlations between MSBP and IMT, between lead level and the number of atherosclerotic plaques, and between lead level and PP. Multivariate stepwise regression analysis demonstrated that higher lead level in blood and higher triglyceride concentration in blood represent independent risk factors of an increased pulse pressure in the group of individuals occupationally exposed to lead. Occupational exposure to lead can be associated with increased blood pressure and accelerated progression of atherosclerosis.

  2. Effects of environmental parameters and irrigation on the turgor pressure of banana plants measured using the non-invasive, online monitoring leaf patch clamp pressure probe.

    Science.gov (United States)

    Zimmermann, U; Rüger, S; Shapira, O; Westhoff, M; Wegner, L H; Reuss, R; Gessner, P; Zimmermann, G; Israeli, Y; Zhou, A; Schwartz, A; Bamberg, E; Zimmermann, D

    2010-05-01

    Turgor pressure provides a sensitive indicator for irrigation scheduling. Leaf turgor pressure of Musa acuminate was measured by using the so-called leaf patch clamp pressure probe, i.e. by application of an external, magnetically generated and constantly retained clamp pressure to a leaf patch and determination of the attenuated output pressure P(p) that is highly correlated with the turgor pressure. Real-time recording of P(p) values was made using wireless telemetric transmitters, which send the data to a receiver base station where data are logged and transferred to a GPRS modem linked to an Internet server. Probes functioned over several months under field and laboratory conditions without damage to the leaf patch. Measurements showed that the magnetic-based probe could monitor very sensitively changes in turgor pressure induced by changes in microclimate (temperature, relative humidity, irradiation and wind) and irrigation. Irrigation effects could clearly be distinguished from environmental effects. Interestingly, oscillations in stomatal aperture, which occurred frequently below turgor pressures of 100 kPa towards noon at high transpiration or at high wind speed, were reflected in the P(p) values. The period of pressure oscillations was comparable with the period of oscillations in transpiration and photosynthesis. Multiple probe readings on individual leaves and/or on several leaves over the entire height of the plants further emphasised the great impact of this non-invasive turgor pressure sensor system for elucidating the dynamics of short- and long-distance water transport in higher plants.

  3. [Effect of oxygen partial pressure on the band-gap of the TiO2 films prepared by DC reactive sputtering].

    Science.gov (United States)

    Zhao, Qing-nan; Li, Chun-ling; Liu, Bao-shun; Zhao, Xiu-jian

    2004-05-01

    TiO2 films have been deposited on glass substrates using DC reactive magnetron sputtering at different oxygen partial pressures from 0.10 to 0.65 Pa. The photoluminescence (PL) spectra of the films were recorded. The results of the PL spectra showed that there were three emission peaks at 370, 472 and 514 nm for the films sputtered at 0.35 and 0.65 Pa, and there were two peaks at 370 and 490 nm for the films sputtered at 0.10 and 0.15 Pa. The band-gap for the films was 3.35 eV. For the films sputtered at 0.35 and 0.65 Pa there were two defect energy levels at 2.63 and 2.41 eV, corresponding to 0.72 and 0.94 eV below conduction band for the band-gap, respectively. For the films sputtered at 0.10 and 0.15 Pa, there was an energy band formed between 3.12 and 2.06 eV, corresponding to 0.23 and 1.29 eV below the conduction band. With increasing the oxygen partial pressure, the defect energy band changed to two energy levels, and the energy levels nearly disappeared for the film sputtered at 0.65 Pa of oxygen partial pressure.

  4. Effect of oxygen partial pressure on the structural and optical properties of ion beam sputtered TiO2 thin films

    Science.gov (United States)

    Tantray, Firdous A.; Chouhan, Romita; Rajput, Swati; Agrawal, Arpana; Andrews, Joseph T.; Sen, Pranay K.; Gupta, Mukul; Sen, Pratima

    2016-10-01

    We report the effect of oxygen partial pressure on the structural, electronic and nonlinear optical properties of ion beam sputtered TiO2 thin films deposited on glass substrate at 40% of oxygen (S1) and 20% of oxygen (S2) partial pressure. XRD data shows the crystalline nature of S1 film while the film S2 was amorphous in nature. The energy band gap of the thin films calculated from their UV-Vis spectra was found to be 3.63 eV (S1) and 3.56 eV (S2). The decrease in the band gap with decrease in oxygen partial pressure may be attributed to the amorphous nature of the film. The nonlinear refractive indices for both the films were obtained from the closed aperture Z-scan experiment performed using a cw He-Ne laser source operating at 632.8 nm and were found to be 17.6×10-9 m2/W and -5.64×10-9 m2/W for S1and S2 films, respectively. The reversal in the sign of the nonlinear refractive index may also be ascribed to the crystallinity of the grown films.

  5. The Effect of Sintering Oxygen Partial Pressure on a SmBiO3 Buffer Layer for Coated Conductors via Chemical Solution Deposition

    Directory of Open Access Journals (Sweden)

    Xiaolei Zhu

    2016-10-01

    Full Text Available The application of high-temperature YBa2Cu3O7−δ (YBCO superconducting material is a considerable prospect for the growing energy shortages. Here, SmBiO3 (SBO films were deposited on (100-orientated yttrium-stabilized zirconia (YSZ simple crystal substrates via the chemical solution deposition (CSD approach for coated conductors, and the effects of sintering oxygen partial pressure on SBO films were studied. The crystalline structures and surface morphologies of SBO films were characterized by X-ray diffraction (XRD, scanning electron microscopy (SEM, and atomic force microscope (AFM. The optimized growth temperature, the intensity ratios of the SBO (200 peak to the SBO (111 peak, and the crystallinities of SBO films increased with the sintering oxygen partial pressure. The SEM and AFM images displayed a smooth and well-distributed surface in the argon atmosphere. The subsequent YBCO films with superconducting transition temperatures (Tc = 89.5 K, 90.2 K, and 86.2 K and critical current densities (Jc = 0.88 MA/cm2, 1.69 MA/cm2, and 0.09 MA/cm2; 77 K, self-field were deposited to further check the qualities of the SBO layer. These results indicated that sintering oxygen partial pressure had an effect on the epitaxial growth of the SBO buffer layer and YBCO superconducting properties. The experimental results may be a usable reference for the epitaxial growth of YBCO-coated conductors and other oxides.

  6. Monitoring Process Water Quality Using Near Infrared Spectroscopy and Partial Least Squares Regression with Prediction Uncertainty Estimation.

    Science.gov (United States)

    Skou, Peter B; Berg, Thilo A; Aunsbjerg, Stina D; Thaysen, Dorrit; Rasmussen, Morten A; van den Berg, Frans

    2017-03-01

    Reuse of process water in dairy ingredient production-and food processing in general-opens the possibility for sustainable water regimes. Membrane filtration processes are an attractive source of process water recovery since the technology is already utilized in the dairy industry and its use is expected to grow considerably. At Arla Foods Ingredients (AFI), permeate from a reverse osmosis polisher filtration unit is sought to be reused as process water, replacing the intake of potable water. However, as for all dairy and food producers, the process water quality must be monitored continuously to ensure food safety. In the present investigation we found urea to be the main organic compound, which potentially could represent a microbiological risk. Near infrared spectroscopy (NIRS) in combination with multivariate modeling has a long-standing reputation as a real-time measurement technology in quality assurance. Urea was quantified Using NIRS and partial least squares regression (PLS) in the concentration range 50-200 ppm (RMSEP = 12 ppm, R(2 )= 0.88) in laboratory settings with potential for on-line application. A drawback of using NIRS together with PLS is that uncertainty estimates are seldom reported but essential to establishing real-time risk assessment. In a multivariate regression setting, sample-specific prediction errors are needed, which complicates the uncertainty estimation. We give a straightforward strategy for implementing an already developed, but seldom used, method for estimating sample-specific prediction uncertainty. We also suggest an improvement. Comparing independent reference analyses with the sample-specific prediction error estimates showed that the method worked on industrial samples when the model was appropriate and unbiased, and was simple to implement.

  7. Multipoint Pressure and Temperature Sensing Fiber Optic Cable for Monitoring CO2 Sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Challener, William

    2014-12-31

    This report describes the work completed on contract DE-FE0010116. The goal of this two year project was to develop and demonstrate in the laboratory a highly accurate multi-point pressure measurement fiber optic cable based on MEMS pressure sensors suitable for downhole deployment in a CO2 sequestration well. The sensor interrogator was also to be demonstrated in a remote monitoring system and environmental testing was to be completed to indicate its downhole survivability over a lengthy period of time (e.g., 20 years). An interrogator system based on a pulsed laser excitation was shown to be capable of multiple (potentially 100+) simultaneous sensor measurements. Two sensors packages were completed and spliced in a cable onto the same fiber and measured. One sensor package was subsequently measured at high temperatures and pressures in supercritical CO2, while the other package was measured prior and after being subjected to high torque stresses to mimic downhole deployment. The environmental and stress tests indicated areas in which the package design should be further improved.

  8. [Ambulatory blood pressure monitoring is a useful tool for all patients].

    Science.gov (United States)

    de la Sierra, A

    Clinical blood pressure measurement (BP) is an occasional and imperfect way of estimating this biological variable. Ambulatory blood pressure monitoring (ABPM) is by far the best clinical tool for measuring an individual's blood pressure. Mean values over 24h, through the daytime and at night all make it more possible to predict organic damage and the future development of the disorder. ABPM enables the detection of white-coat hypertension and masked hypertension in both the diagnosis and follow-up of treated patients. Although some of the advantages of ABPM can be reproduced by more automated measurement without the presence of an observer in the clinic or self-measurement at home, there are some other elements of great interest that are unique to ABPM, such as seeing what happens to a patient's BP at night, the night time dipping pattern and short-term variability, all of which relate equally to the patient's prognosis. There is no scientific or clinical justification for denying these advantages, and ABPM should form part of the evaluation and follow-up of practically all hypertensive patients. Rather than continuing unhelpful discussions as to its availability and acceptability, we should concentrate our efforts on ensuring its universal availability and clearly explaining its advantages to both doctors and patients. Copyright © 2016 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Ambulatory blood pressure monitoring in patients with hyperthyroidism before and after control of thyroid function.

    Science.gov (United States)

    Iglesias, P; Acosta, M; Sánchez, R; Fernández-Reyes, M J; Mon, C; Díez, J J

    2005-07-01

    Thyroid hormones have pronounced effects on the cardiovascular system. Thyrotoxicosis affects blood pressure (BP), modifying both diastolic (DBP) and systolic (SBP) pressures. There are no studies examining BP with ambulatory blood pressure monitoring (ABPM) in hyperthyroidism before and after control of thyroid function. Our aims were (1) to analyse ABPM in a group of normotensive hyperthyroid patients before and after normalizing circulating thyroid hormones and (2) to compare these results with those obtained in a group of euthyroid subjects. We studied 20 normotensive hyperthyroid subjects [18 women; age (mean +/- SEM) 49.0 +/- 3.0 years] and 15 healthy subjects. Patients were evaluated by ABPM over 24 h, at diagnosis and after therapy (n = 18). The average 24-h, daytime and night-time SBP was significantly greater in hyperthyroid patients than in controls with no significant differences in DBP. Circadian BP rhythm, estimated by the difference between mean values of SBP, DBP and mean BP during daytime and night-time, was unchanged. The average 24-h and daytime SBP significantly decreased after normalizing thyroid function in the 18 hyperthyroid evaluated patients. Daytime SBP and DBP were higher than night-time values both before and after control of thyroid function. However, no differences in circadian BP rhythm were observed. Normotensive hyperthyroid patients exhibit higher ambulatory SBP throughout 24 h than normotensive euthyroid subjects. Control of hyperthyroidism decreases ambulatory SBP values. Mean nocturnal fall in BP is comparable in normotensive hyperthyroid patients and control subjects.

  10. Multipoint Pressure and Temperature Sensing Fiber Optic Cable for Monitoring CO2 Sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Challener, William [General Electric Company, Niskayuna, NY (United States)

    2015-02-10

    This report describes the work completed on contract DE-FE0010116. The goal of this two year project was to develop and demonstrate in the laboratory a highly accurate multi-point pressure measurement fiber optic cable based on MEMS pressure sensors suitable for downhole deployment in a CO2 sequestration well. The sensor interrogator was also to be demonstrated in a remote monitoring system and environmental testing was to be completed to indicate its downhole survivability over a lengthy period of time (e.g., 20 years). An interrogator system based on a pulsed laser excitation was shown to be capable of multiple (potentially 100+) simultaneous sensor measurements. Two sensors packages were completed and spliced in a cable onto the same fiber and measured. One sensor package was subsequently measured at high temperatures and pressures in supercritical CO2, while the other package was measured prior and after being subjected to high torque stresses to mimic downhole deployment. The environmental and stress tests indicated areas in which the package design should be further improved.

  11. Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor.

    Science.gov (United States)

    Nam, Yunyoung; Kim, Yeesock; Lee, Jinseok

    2016-05-23

    Sleep disorders are a common affliction for many people even though sleep is one of the most important factors in maintaining good physiological and emotional health. Numerous researchers have proposed various approaches to monitor sleep, such as polysomnography and actigraphy. However, such approaches are costly and often require overnight treatment in clinics. With this in mind, the research presented here has emerged from the question: "Can data be easily collected and analyzed without causing discomfort to patients?" Therefore, the aim of this study is to provide a novel monitoring system for quantifying sleep quality. The data acquisition system is equipped with multimodal sensors, including a three-axis accelerometer and a pressure sensor. To identify sleep quality based on measured data, a novel algorithm, which uses numerous physiological parameters, was proposed. Such parameters include non-REM sleep time, the number of apneic episodes, and sleep durations for dominant poses. To assess the effectiveness of the proposed system, three participants were enrolled in this experimental study for a duration of 20 days. From the experimental results, it can be seen that the proposed monitoring system is effective for quantifying sleep quality.

  12. Limitations of stroke volume estimation by non-invasive blood pressure monitoring in hypergravity.

    Directory of Open Access Journals (Sweden)

    Olivier Manen

    Full Text Available Altitude and gravity changes during aeromedical evacuations induce exacerbated cardiovascular responses in unstable patients. Non-invasive cardiac output monitoring is difficult to perform in this environment with limited access to the patient. We evaluated the feasibility and accuracy of stroke volume estimation by finger photoplethysmography (SVp in hypergravity.Finger arterial blood pressure (ABP waveforms were recorded continuously in ten healthy subjects before, during and after exposure to +Gz accelerations in a human centrifuge. The protocol consisted of a 2-min and 8-min exposure up to +4 Gz. SVp was computed from ABP using Liljestrand, systolic area, and Windkessel algorithms, and compared with reference values measured by echocardiography (SVe before and after the centrifuge runs.The ABP signal could be used in 83.3% of cases. After calibration with echocardiography, SVp changes did not differ from SVe and values were linearly correlated (p<0.001. The three algorithms gave comparable SVp. Reproducibility between SVp and SVe was the best with the systolic area algorithm (limits of agreement -20.5 and +38.3 ml.Non-invasive ABP photoplethysmographic monitoring is an interesting technique to estimate relative stroke volume changes in moderate and sustained hypergravity. This method may aid physicians for aeronautic patient monitoring.

  13. Re-evaluation of Pre-pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients.

    Science.gov (United States)

    Shibata, Eriko; Nagai, Kojiro; Takeuchi, Risa; Noda, Yasuhiro; Makino, Tomomi; Chikata, Yusuke; Hann, Michael; Yoshimoto, Sakiya; Ono, Hiroyuki; Ueda, Sayo; Tamaki, Masanori; Murakami, Taichi; Matsuura, Motokazu; Abe, Hideharu; Doi, Toshio

    2015-07-01

    Prepump arterial pressure (PreAP) is monitored to avoid generating excessive negative pressure. The National Kidney Foundation K/DOQI clinical practice guidelines for vascular access recommend that PreAP should not fall below -250 mm Hg because excessive negative PreAP can lead to a decrease in the delivery of blood flow, inadequate dialysis, and hemolysis. Nonetheless, these recommendations are consistently disregarded in clinical practice and pressure sensors are often removed from the dialysis circuit. Thus far, delivered blood flow has been reported to decrease at values more negative than -150 mm Hg of PreAP. These values have been analyzed by an ultrasonic flowmeter and not directly measured. Furthermore, no known group has evaluated whether PreAP-induced hemolysis occurs at a particular threshold. Therefore, the aim of this study was to clarify the importance of PreAP in the prediction of inadequate dialysis and hemolysis. By using different diameter needles, human blood samples from healthy volunteers were circulated in a closed dialysis circuit. The relationship between PreAP and delivered blood flow or PreAP and hemolysis was investigated. We also investigated the optimal value for PreAP using several empirical monitoring methods, such as a pressure pillow. Our investigation indicated that PreAP is a critical factor in the determination of delivered blood flow and hemolysis, both of which occured at pressure values more negative than -150 mm Hg. With the exception of direct pressure monitoring, commonly used monitoring methods for PreAP were determined to be ineffective. We propose that the use of a vacuum monitor would permit regular measurement of PreAP. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Global Ocean Surface Water Partial Pressure of CO2 Database: Measurements Performed During 1968-2007 (Version 2007)

    Energy Technology Data Exchange (ETDEWEB)

    Kozyr, Alex [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Carbon Dioxide Information Analysis Center

    2008-09-30

    More than 4.1 million measurements of surface water partial pressure of CO2 obtained over the global oceans during 1968-2007 are listed in the Lamont-Doherty Earth Observatory (LDEO) database, which includes open ocean and coastal water measurements. The data assembled include only those measured by equilibrator-CO2 analyzer systems and have been quality-controlled based on the stability of the system performance, the reliability of calibrations for CO2 analysis, and the internal consistency of data. To allow re-examination of the data in the future, a number of measured parameters relevant to pCO2 measurements are listed. The overall uncertainty for the pCO2 values listed is estimated to be ± 2.5 µatm on the average. For simplicity and for ease of reference, this version is referred to as 2007, meaning that data collected through 31 December 2007 has been included. It is our intention to update this database annually. There are 37 new cruise/ship files in this update. In addition, some editing has been performed on existing files so this should be considered a V2007 file. Also we have added a column reporting the partial pressure of CO2 in seawater in units of Pascals. The data presented in this database include the analyses of partial pressure of CO2 (pCO2), sea surface temperature (SST), sea surface salinity (SSS), pressure of the equilibration, and barometric pressure in the outside air from the ship’s observation system. The global pCO2 data set is available free of charge as a numeric data package (NDP) from the Carbon Dioxide Information Analysis Center (CDIAC). The NDP consists of the oceanographic data files and this printed documentation, which describes the procedures and methods used to obtain the data.

  15. Monitoring of total positive end-expiratory pressure during mechanical ventilation by artificial neural networks.

    Science.gov (United States)

    Perchiazzi, Gaetano; Rylander, Christian; Pellegrini, Mariangela; Larsson, Anders; Hedenstierna, Göran

    2016-04-11

    Ventilation treatment of acute lung injury (ALI) requires the application of positive airway pressure at the end of expiration (PEEPapp) to avoid lung collapse. However, the total pressure exerted on the alveolar walls (PEEPtot) is the sum of PEEPapp and intrinsic PEEP (PEEPi), a hidden component. To measure PEEPtot, ventilation must be discontinued with an end-expiratory hold maneuver (EEHM). We hypothesized that artificial neural networks (ANN) could estimate the PEEPtot from flow and pressure tracings during ongoing mechanical ventilation. Ten pigs were mechanically ventilated, and the time constant of their respiratory system (τRS) was measured. We shortened their expiratory time (TE) according to multiples of τRS, obtaining different respiratory patterns (Rpat). Pressure (PAW) and flow (V'AW) at the airway opening during ongoing mechanical ventilation were simultaneously recorded, with and without the addition of external resistance. The last breath of each Rpat included an EEHM, which was used to compute the reference PEEPtot. The entire protocol was repeated after the induction of ALI with i.v. injection of oleic acid, and 382 tracings were obtained. The ANN had to extract the PEEPtot, from the tracings without an EEHM. ANN agreement with reference PEEPtot was assessed with the Bland-Altman method. Bland Altman analysis of estimation error by ANN showed -0.40 ± 2.84 (expressed as bias ± precision) and ±5.58 as limits of agreement (data expressed as cmH2O). The ANNs estimated the PEEPtot well at different levels of PEEPapp under dynamic conditions, opening up new possibilities in monitoring PEEPi in critically ill patients who require ventilator treatment.

  16. Unconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor.

    Science.gov (United States)

    Nishiyama, Michiko; Sonobe, Masako; Watanabe, Kazuhiro

    2016-09-01

    In this paper, we present a pulse pressure waveform sensor that does not constrain a wearer's daily activity; the sensor uses hetero-core fiber optics. Hetero-core fiber sensors have been found to be sensitive to moderate bending. To detect minute pulse pressure changes from the radial artery at the wrist, we devised a fiber sensor arrangement using three-point bending supports. We analyzed and evaluated the measurement validity using wavelet transformation, which is well-suited for biological signal processing. It was confirmed that the detected pulse waveform had a fundamental mode frequency of around 1.25 Hz over the time-varying waveform. A band-pass filter with a range of frequencies from 0.85 to 1.7 Hz was used to pick up the fundamental mode. In addition, a high-pass filter with 0.85 Hz frequency eliminated arm motion artifacts; consequently, we achieved high signal-to-noise ratio. For unrestricted daily health management, it is desirable that pulse pressure monitoring can be achieved by simply placing a device on the hand without the sensor being noticed. Two types of arrangements were developed and demonstrated in which the pulse sensors were either embedded in a base, such as an armrest, or in a wearable device. A wearable device without cuff pressure using a sensitivity-enhanced fiber sensor was successfully achieved with a sensitivity of 0.07-0.3 dB with a noise floor lower than 0.01 dB for multiple subjects.

  17. Electrical properties of InGaN thin films grown by RF sputtering at different temperatures, varying nitrogen and argon partial pressure ratios

    Science.gov (United States)

    Jakkala, Pratheesh; Kordesch, Martin E.

    2016-10-01

    Indium gallium nitride (InGaN) thin films of varying indium (In) and gallium (Ga) compositions have been fabricated on aluminosilicate glass and silicon (111) substrates using RF magnetron sputtering method at different growth temperatures, varied from 35 °C to 450 °C. Argon (Ar) and nitrogen (N2) are used as Inert and reactive gases respectively. Keeping the total pressure of gas mixture constant, partial pressures of N2 and Ar gases are varied. Ratio of Ar partial pressure to total pressure in the gas mixture is varied from 0 to 0.75. In this study, we present electrical properties of these InGaN thin films. Resistivity values of 2.6 × 10-5 to 1.68 × 10-2 Ω.cm, mobility values of 0.119 to 45.2 cm2/V.s, conductivity values of 0.595 × 103 to 37.3 × 103 mho/cm and bulk carrier concentration values -1020 to -1022/m3 are recorded that are measured through Hall-effect measurement technique.

  18. Intraocular Pressure Fluctuations and 24-Hour Continuous Monitoring for Glaucoma Risk in Wind Instrument Players.

    Science.gov (United States)

    de Crom, Ronald M P C; Webers, Carroll A B; van Kooten-Noordzij, Marina A W; Michiels, Agnes C; Schouten, Jan S A G; Berendschot, Tos T J M; Beckers, Henny J M

    2017-08-30

    The purpose of this study is to investigate the influence of playing a wind instrument on intraocular pressure (IOP) and to monitor 24-hour (IOP) fluctuations in wind musicians of symphony and wind orchestras to compare IOP levels during normal daily activities with IOP levels during playing. Professional and amateur musicians of symphony and wind orchestras were invited to participate. A total of 42 participants, 9 with glaucoma, underwent a routine ophthalmologic examination. IOP measurements were taken before and immediately after 20 minutes of playing wind instruments. In addition, 6 participants underwent 24-hour IOP monitoring with the Triggerfish (Sensimed AG, Switzerland) sensing contact lens, during which they kept an activity logbook. Eleven professionals and 31 amateur musicians participated in the study. A total of 7 eyes of 6 patients underwent additional 24-hour IOP monitoring. Mean IOP before playing was 13.6±2.6 mm Hg, IOP change after playing was +1.5±2.2 mm Hg with a significant difference between professionals (2.5±1.5 mm Hg) and amateurs (1.1±2.3 mm Hg). There were no significant differences in IOP change between subjects with or without glaucoma. During 24-hour IOP monitoring there were slight increases in IOP while playing an instrument, but also during other activities and overnight. These latter IOP levels were similar or even higher than the IOP rise caused by playing a wind instrument. IOP often rises after playing wind instruments, but similar or even higher IOP levels seem to occur during common other daily activities or at night. These peaks may be relevant for glaucomatous field progression and treatment of glaucoma patients.

  19. Controlling mechanisms of surface partial pressure of CO2 in Jiaozhou Bay during summer and the influence of heavy rain

    Science.gov (United States)

    Li, Yunxiao; Yang, Xufeng; Han, Ping; Xue, Liang; Zhang, Longjun

    2017-09-01

    Due to the combined effects of natural processes and human activities, carbon source/sink processes and mechanisms in the coastal ocean are becoming more and more important in current ocean carbon cycle research. Based on differences in the ratio of total alkalinity (TA) to dissolved inorganic carbon (DIC) associated with terrestrial input, biological process (production and respiration), calcium carbonate (CaCO3) process (precipitation and dissolution) and CO2 evasion/invasion, we discuss the mechanisms controlling the surface partial pressure of CO2 (pCO2) in Jiaozhou Bay (JZB) during summer and the influence of heavy rain, via three cruises performed in mid-June, early July and late July of 2014. In mid-June and in early July, without heavy rain or obvious river input, sea surface pCO2 ranged from 521 to 1080 μatm and from 547 to 998 μatm, respectively. The direct input of DIC from sewage and the intense respiration produced large DIC additions and the highest pCO2 values in the northeast of the bay near the downtown of Qingdao. However, in the west of the bay, significant CaCO3 precipitation led to DIC removal but no obvious increase in pCO2, which was just close to that in the central area. Due to the shallow depth and longer water residence time in this region, this pattern may be related to the sustained release of CO2 into the atmosphere. In late July, heavy rain promoted river input in the western and eastern portions of JZB. Strong primary production led to a significant decrease in pCO2 in the western area, with the lowest pCO2 value of 252 μatm. However, in the northeastern area, the intense respiration remained, and the highest pCO2 value was 1149 μatm. The average air-sea CO2 flux in mid-June and early July was 20.23 mmol m- 2 d- 1 and 23.56 mmol m- 2 d- 1, respectively. In contrast, in late July, sources became sinks for atmospheric CO2 in the western and central areas of the bay, halving the average air-sea CO2 flux to a value of 10.58 mmol m- 2

  20. Analysis of novel geometry-independent method for dialysis access pressure-flow monitoring

    Directory of Open Access Journals (Sweden)

    Panduranga Harsha

    2008-11-01

    Full Text Available Abstract Background End-stage renal disease (ESRD confers a large health-care burden for the United States, and the morbidity associated with vascular access failure has stimulated research into detection of vascular access stenosis and low flow prior to thrombosis. We present data investigating the possibility of using differential pressure (ΔP monitoring to estimate access flow (Q for dialysis access monitoring, with the goal of utilizing micro-electro-mechanical systems (MEMS pressure sensors integrated within the shaft of dialysis needles. Methods A model of the arteriovenous graft fluid circuit was used to study the relationship between Q and the ΔP between two dialysis needles placed 2.5–20.0 cm apart. Tubing was varied to simulate grafts with inner diameters of 4.76–7.95 mm. Data were compared with values from two steady-flow models. These results, and those from computational fluid dynamics (CFD modeling of ΔP as a function of needle position, were used to devise and test a method of estimating Q using ΔP and variable dialysis pump speeds (variable flow that diminishes dependence on geometric factors and fluid characteristics. Results In the fluid circuit model, ΔP increased with increasing volume flow rate and with increasing needle-separation distance. A nonlinear model closely predicts this ΔP-Q relationship (R2 > 0.98 for all graft diameters and needle-separation distances tested. CFD modeling suggested turbulent needle effects are greatest within 1 cm of the needle tip. Utilizing linear, quadratic and combined variable flow algorithms, dialysis access flow was estimated using geometry-independent models and an experimental dialysis system with the pressure sensors separated from the dialysis needle tip by distances ranging from 1 to 5 cm. Real-time ΔP waveform data were also observed during the mock dialysis treatment, which may be useful in detecting low or reversed flow within the access. Conclusion With further

  1. Can ambulatory blood-pressure monitoring provide reliable indices of arterial stiffness?

    Science.gov (United States)

    Gosse, Philippe; Papaioanou, Georgios; Coulon, Paul; Reuter, Sylvain; Lemetayer, Philippe; Safar, Michel

    2007-08-01

    The use of ambulatory recordings of blood pressure (BP) was proposed to estimate arterial stiffness (AS). We compared the relative value of the ambulatory AS index (AASI), and of the slope of pulse pressure (PP) according to mean BP (MBP) obtained from 24-h ambulatory BP monitoring, to the monitoring of the arrival time of Korotkoff sounds (QKD interval) in the prediction of cardiovascular (CV) events. Twenty-four-hour ambulatory BP and QKD monitoring were recorded at baseline, before antihypertensive treatment of hypertensive patients in our Bordeaux cohort. From these recordings, the AASI, the PP/MBP slope, and the theoretical value of the QKD for a systolic pressure of 100 mm Hg and a heart rate of 60 beats/min (QKD100-60) were calculated. The patients were then given antihypertensive treatment and followed by their family physicians, who were unaware of the QKD, AASI, and PP/MBP slope results. Regular updates on patients were obtained. The reproducibility of measurements was studied in 38 normal subjects evaluated on two occasions. The reproducibility of the AASI and the PP/MBP slope was less than that of BP over 24 h and of QKD100-60. The cohort comprised 469 patients. With an average follow-up of 70+/-39 months, 62 CV complications, including 13 deaths, were recorded. In the monovariate analysis, age, PP over 24 h, QKD100-60, AASI, and the PP/MBP slope were significantly related to the occurrence of complications. In the multivariate analysis, when age and PP over 24 were included in the model, only QKD100-60 remained significantly linked to CV events. Our data support the value of the AASI as an indirect estimate of AS and as an element in the evaluation of CV risk in hypertensive patients. However, the reproducibility of this index is less, and its predictive value for complications is poorer, than that of QKD100-60, a parameter that we believe is more closely linked to AS.

  2. Third ventriculostomy through the lamina terminalis for intracranial pressure monitoring after aneurysm surgery: technical note

    Directory of Open Access Journals (Sweden)

    Kraemer Jorge L.

    2002-01-01

    Full Text Available OBJECTIVE: A new ventriculostomy technique through the lamina terminalis is described. This technique is applied mainly during aneurysm surgery at the acute stage. METHOD: Thirteen patients were operated on intracranial aneurysms and, during the procedure, had the lamina terminalis fenestrated. A ventricular catheter was inserted into the third ventricule, left in place and connected to an external drainage system for further intracranial pressure (ICP monitoring and/or cerebrospinal fluid (CSF drainage. RESULTS: ICP readings and CSF drainage were obtained in all cases. No complication was recorded. CONCLUSION: Third ventriculostomy through the lamina terminalis is a simple and easy technique that can be used as an alternative to conventional ventriculostomy. This procedure can be indicated in cases where the ventricule is not reached by means of another technique, and when the decision to perform ventriculostomy is made at the end of aneurysm surgery.

  3. Application of Ambulatory Blood Pressure Monitoring Essential Hypertension with Target-Organ Damage

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@The purpose of this study was to determine whether this normal ambulatory blood pressure (ABP) criterion deter-mined by JVC-VI was suitable for Chinese patients with es-sential hypertention (EH), in order to decrease target organ damage (TOD). 24-hour ABP monitoring (ABPM) results in 1 325 cases with reliable data according with the selected criteria were investigated. 106 normotensives (65 men, 41women, mean age 52 years), 498 untreated simple hyper-tensives (288 men, 210 women, mean age 54 years) and 722 recently untreated hypertensives with TOD (490 men,232 women, mean age 58 years) including 53% cardiac damage, 16% cerebral damage, 9% renal damage and 22 % more than one organ damage were studied.

  4. Blood Pressure Deviations From Optimal Mean Arterial Pressure During Cardiac Surgery Measured With a Novel Monitor of Cerebral Blood Flow and Risk for Perioperative Delirium: A Pilot Study.

    Science.gov (United States)

    Hori, Daijiro; Max, Laura; Laflam, Andrew; Brown, Charles; Neufeld, Karin J; Adachi, Hideo; Sciortino, Christopher; Conte, John V; Cameron, Duke E; Hogue, Charles W; Mandal, Kaushik

    2016-06-01

    The aim of this study was to evaluate whether excursions of blood pressure from the optimal mean arterial pressure during and after cardiac surgery are associated with postoperative delirium identified using a structured examination. Prospective, observational study. University hospital. The study included 110 patients undergoing cardiac surgery. Patients were monitored using ultrasound-tagged near-infrared spectroscopy to assess optimal mean arterial pressure by cerebral blood flow autoregulation monitoring during cardiopulmonary bypass and the first 3 hours in the intensive care unit. The patients were tested preoperatively and on postoperative days 1 to 3 with the Confusion Assessment Method or Confusion Assessment Method for the Intensive Care Unit, the Delirium Rating Scale-Revised-98, and the Mini Mental State Examination. Summative presence of delirium on postoperative days 1 through 3, as defined by the consensus panel following Diagnostic and Statistical Manual of Mental Disorders-IV-TR criteria, was the primary outcome. Delirium occurred in 47 (42.7%) patients. There were no differences in blood pressure excursions above and below optimal mean arterial pressure between patients with and without summative presence of delirium. Secondary analysis showed blood pressure excursions above the optimal mean arterial pressure to be higher in patients with delirium (mean±SD, 33.2±26.51 mmHgxh v 23.4±16.13 mmHgxh; p = 0.031) and positively correlated with the Delirium Rating Scale score on postoperative day 2 (r = 0.27, p = 0.011). Summative presence of delirium was not associated with perioperative blood pressure excursions; but on secondary exploratory analysis, excursions above the optimal mean arterial pressure were associated with the incidence and severity of delirium on postoperative day 2. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Peripheral arterial blood pressure versus central crterial blood pressure monitoring in critically ill patients after Cardio-pulmonary Bypass.

    Science.gov (United States)

    Ahmad, Rana Altaf; Ahmad, Suhail; Naveed, Anjum; Baig, Mirza Ahmad Raza

    2017-01-01

    To determine the accuracy of peripheral (radial) arterial access as compared to central (femoral) arterial access for measurement of invasive blood pressure (IBP) in critically ill patients after cardiopulmonary bypass. Sixty patients (60) who required high inotropic/vasopressor support on weaning from cardio-pulmonary bypass and weaned off in 2(nd) attempt were included in this study. The duration of this study was from June 2015 to August 2016. Radial and femoral arterial access was achieved in all patients for simultaneous measurement of blood pressure. Arterial pressures were noted after 5, 15 and 30 minutes of weaning from cardiopulmonary bypass for both radial and femoral artery simultaneously. Mean age of study patients was 56.48±11.17 years. 85% patients were male. There was significant difference in systolic blood pressure, diastolic blood pressure and mean arterial pressures between the radial artery and femoral artery cannulation. Mean arterial pressures were significantly high in femoral artery as compared to the radial artery. The mean arterial pressures after five minutes of weaning using central access were 76.28±10.21 mmHg versus 64.15±6.76 mmHg in peripheral arterial access (p-value arterial pressures after 15 minutes of weaning from cardiopulmonary bypass 78.70±10.12 mmHg in central access versus 72.03±6.76 mmHg using peripheral arterial access (p-value arterial pressures were less marked as compared to the previous differences after 30 minutes of weaning from cardiopulmonary bypass as compared to the earlier readings (p-value 0.001). Peripheral arterial pressures are unreliable in critically ill patients after cardiopulmonary bypass receiving high dose of inotropic drugs. Central arterial access should be used in these patients to get accurate estimates of patients' blood pressure in early periods after cardiopulmonary bypass.

  6. Validity and reliability of a pressure ulcer monitoring tool for persons with spinal cord impairment.

    Science.gov (United States)

    Thomason, Susan S; Luther, Stephen L; Powell-Cope, Gail M; Harrow, Jeffrey J; Palacios, Polly

    2014-05-01

    The purpose was to provide support for validity and reliability of the spinal cord impairment pressure ulcer monitoring tool (SCI-PUMT) to assess pressure ulcer (PrU) healing. Expert panels developed a 30-item pool, including new items and items from two established PrU healing tools, to represent potential variables for monitoring PrU healing. Subjects were prospectively assessed weekly for each variable over a 12-week period. Data collection was conducted on a cohort of inpatients and outpatients in one Spinal Cord Injury/Disorders Center in the Veterans' Health Administration. A convenience sample of Veterans (n = 66) with spinal cord impairment (SCI) was recruited. Eligible subjects had at least one PrU (n = 167) and a history of SCI for longer than 1 year. Interventions Not applicable. A change in PrU volume was calculated using VeV Measurement Documentation software and a digital imaging camera. Content validity was established for a pool of items designed to gauge PrU healing. Exploratory factor analysis (construct validity) identified a parsimonious set of seven items for inclusion in the SCI-PUMT to assess PrU healing. The SCI-PUMT was found to explain 59% of the variance of the volume across the study. Inter-rater reliability was 0.79 and intra-rater reliability ranged from 0.81 to 0.99 among research assistants. Similar levels of reliability were subsequently established among registered nurses, who used the SCI-PUMT in the clinical setting. The final version of the SCI-PUMT was determined to be valid, reliable, and sensitive in detecting PrU healing over time in Veterans with SCI.

  7. BION-M 1: First continuous blood pressure monitoring in mice during a 30-day spaceflight

    Science.gov (United States)

    Andreev-Andrievskiy, Alexander; Popova, Anfisa; Lloret, Jean-Christophe; Aubry, Patrick; Borovik, Anatoliy; Tsvirkun, Daria; Vinogradova, Olga; Ilyin, Eugeniy; Gauquelin-Koch, Guillemette; Gharib, Claude; Custaud, Marc-Antoine

    2017-05-01

    Animals are an essential component of space exploration and have been used to demonstrate that weightlessness does not disrupt essential physiological functions. They can also contribute to space research as models of weightlessness-induced changes in humans. Animal research was an integral component of the 30-day automated Russian biosatellite Bion-M 1 space mission. The aim of the hemodynamic experiment was to estimate cardiovascular function in mice, a species roughly 3000 times smaller than humans, during prolonged spaceflight and post-flight recovery, particularly, to investigate if mice display signs of cardiovascular deconditioning. For the first time, heart rate (HR) and blood pressure (BP) were continuously monitored using implantable telemetry during spaceflight and recovery. Decreased HR and unchanged BP were observed during launch, whereas both HR and BP dropped dramatically during descent. During spaceflight, BP did not change from pre-flight values. However, HR increased, particularly during periods of activity. HR remained elevated after spaceflight and was accompanied by increased levels of exercise-induced tachycardia. Loss of three of the five mice during the flight as a result of the hardware malfunction (unrelated to the telemetry system) and thus the limited sample number constitute the major limitation of the study. For the first time BP and HR were continuously monitored in mice during the 30-day spaceflight and 7-days of post-flight recovery. Cardiovascular deconditioning in these tiny quadruped mammals was reminiscent of that in humans. Therefore, the loss of hydrostatic pressure in space, which is thought to be the initiating event for human cardiovascular adaptation in microgravity, might be of less importance than other physiological mechanisms. Further experiments with larger number of mice are needed to confirm these findings.

  8. Monitoring and Analysis of Transient Pore Water Pressures in Large Suspended Rock Slides near Poschiavo, CH

    Science.gov (United States)

    de Palézieux, Larissa; Loew, Simon; Zwahlen, Peter

    2016-04-01

    Many mountain slopes in the Alps exhibit large compound rock slides or Deep Seated Gravitational Slope Deformations. Due to the basal rupture plane geometry and the cumulative displacement magnitude such landslide bodies are often strongly deformed, highly fractured and - at least locally - very permeable. This can lead to high infiltration rates and low phreatic groundwater tables. This is also the situation in the studied mountain slopes southwest of Poschiavo, where large suspended rockslides occur, with very little surface runoff at high elevations, and torrents developing only at the elevation of the basal rupture planes. Below the landslide toes, at altitudes below ca. 1700 m a.s.l., groundwater appears forming spring lines or distributed spring clusters. Within the scope of the design of a hydropower pump storage plant in the Poschiavo valley by Lagobianco SA (Repower AG), numerous cored and deep boreholes (of 50 to 300 m depth) have been drilled along the planned pressure tunnel alignement at elevations ranging from 963 to 2538 m a.s.l. in the years 2010 and 2012. In several boreholes Lugeon and transient pressure tests were executed and pore water pressure sensors installed in short monitoring sections at various depths. Most of these boreholes intersect deep rockslides in crystalline rocks and limestones, showing highly fragmented rock masses and cohesionless cataclastic shear zones of several tens of meters thickness. This study explores these borehole observations in landslides and adjacent stable slopes and links them to the general hydrologic and hydrogeologic framework. The analysis of the pore water pressure data shows significant variability in seasonal trends and short-term events (from snow melt and summer rain storms) and remarkable pressure differences over short horizontal and vertical distances. This reflects rock mass damage within landslide bodies and important sealing horizons at their base. Based on water balances, the estimated effective

  9. Seventy-two-hour preservation, resuscitation, and transplantation of an isolated rat heart with high partial pressure carbon monoxide gas (PCO = 400 hPa) and high partial pressure carbon dioxide (PCO(2) = 100 hPa).

    Science.gov (United States)

    Hatayama, Naoyuki; Yoshida, Yu; Seki, Kunihiro

    2010-01-01

    The cardiac cavity of an isolated rat heart was filled with a Krebs-Henseleit (KH) solution, and the heart was hung in a high-pressure chamber. After the high-pressure chamber had been filled with a mixed gas (PCO = 400 hPa, PCO(2) = 100 hPa, PO(2) = 900 hPa, PHe = 5600 hPa) and preserved for 72 h, we performed a cervical ectopic heart transplantation on a recipient rat and resuscitated the preserved heart. This is the first incidence in the world of a mammalian organ having been successfully preserved and resuscitated after 72 h via a desiccation method.

  10. An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Yu-Chun Liu

    2015-08-01

    Full Text Available An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm3 with a 1 × 0.6 mm2 on-chip circuit which is small enough to place in human carotid artery.

  11. The Use of Ambulatory Blood Pressure Monitoring As Standard of Care in Pediatrics

    Directory of Open Access Journals (Sweden)

    Caitlin G. Peterson

    2017-06-01

    Full Text Available Hypertension (HTN is a significant global health problem, responsible for 7.5 million deaths each year worldwide. The prevalence of HTN is increasing in the pediatric population likely attributed to the increase in childhood obesity. Recent work has also shown that blood pressure (BP tends to track from childhood to adulthood including BP-related target organ damage. In the last 25–30 years, pediatric use of ambulatory blood pressure monitoring (ABPM has been expanding mainly in the setting of initial elevated BP measurement evaluation, HTN therapy efficacy follow-up, and renal disease. However, there are many clinical areas where ABPM could potentially be used but is currently underutilized. This review summarizes the current knowledge and the uses of pediatric ABPM and explores clinical areas where it can be very useful both to detect HTN and its longitudinal follow-up. And thus, ABPM could serve as a critical tool to potentially prevent early cardiovascular mortality and morbidity in wide variety of populations. With solid data to support ABPM’s superiority over clinic BP measurements and these clinical areas for its expansion, ABPM should now be part of standard of care in BP evaluation and management in pediatrics.

  12. Monitoring Composite Material Pressure Vessels with a Fiber-Optic/Microelectronic Sensor System

    Science.gov (United States)

    Klimcak, C.; Jaduszliwer, B.

    1995-01-01

    We discuss the concept of an integrated, fiber-optic/microelectronic distributed sensor system that can monitor composite material pressure vessels for Air Force space systems to provide assessments of the overall health and integrity of the vessel throughout its entire operating history from birth to end of life. The fiber optic component would include either a semiconductor light emitting diode or diode laser and a multiplexed fiber optic sensing network incorporating Bragg grating sensors capable of detecting internal temperature and strain. The microelectronic components include a power source, a pulsed laser driver, time domain data acquisition hardware, a microprocessor, a data storage device, and a communication interface. The sensing system would be incorporated within the composite during its manufacture. The microelectronic data acquisition and logging system would record the environmental conditions to which the vessel has been subjected to during its storage and transit, e.g., the history of thermal excursions, pressure loading data, the occurrence of mechanical impacts, the presence of changing internal strain due to aging, delamination, material decomposition, etc. Data would be maintained din non-volatile memory for subsequent readout through a microcomputer interface.

  13. Comparisons of Office and 24-Hour Ambulatory Blood Pressure Monitoring in Children with Obstructive Sleep Apnea.

    Science.gov (United States)

    Kang, Kun-Tai; Chiu, Shuenn-Nan; Weng, Wen-Chin; Lee, Pei-Lin; Hsu, Wei-Chung

    2017-03-01

    To compare office blood pressure (BP) and 24-hour ambulatory BP (ABP) monitoring to facilitate the diagnosis and management of hypertension in children with obstructive sleep apnea (OSA). Children aged 4-16 years with OSA-related symptoms were recruited from a tertiary referral medical center. All children underwent overnight polysomnography, office BP, and 24-hour ABP studies. Multiple linear regression analyses were applied to elucidate the association between the apnea-hypopnea index and BP. Correlation and consistency between office BP and 24-hour ABP were measured by Pearson correlation, intraclass correlation, and Bland-Altman analyses. In the 163 children enrolled (mean age, 8.2 ± 3.3 years; 67% male). The prevalence of systolic hypertension at night was significantly higher in children with moderate-to-severe OSA than in those with primary snoring (44.9% vs 16.1%, P = .006). Pearson correlation and intraclass correlation analyses revealed associations between office BP and 24-hour BP, and Bland-Altman analysis indicated an agreement between office and 24-hour BP measurements. However, multiple linear regression analyses demonstrated that 24-hour BP (nighttime systolic BP and mean arterial pressure), unlike office BP, was independently associated with the apnea-hypopnea index, after adjustment for adiposity variables. Twenty-four-hour ABP is more strongly correlated with OSA in children, compared with office BP. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. An improved flexible telemetry system to autonomously monitor sub-bandage pressure and wound moisture.

    Science.gov (United States)

    Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H

    2014-11-18

    This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb.

  15. An Improved Flexible Telemetry System to Autonomously Monitor Sub-Bandage Pressure and Wound Moisture

    Directory of Open Access Journals (Sweden)

    Nasir Mehmood

    2014-11-01

    Full Text Available This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb.

  16. [Arterial pressure-based cardiac output monitoring: 1. FloTrac sensor and SVV].

    Science.gov (United States)

    Seo, Katsuhiro

    2009-07-01

    FloTrac is a recently introduced semi-invasive arterial pressure-based cardiac output (APCO) monitoring device. The accuracy of a new device is usually evaluated by Bland-Altman method, which shows graphically the mean value of differences between a new method and the reference method (bias), standard deviation of the differences (precision) and limits of agreement or 2 standard deviations. Critchley et al calculated the percentage errors which are two standard deviations divided by mean cardiac output, and proposed that percentage error should be less than 30% as a reliable new method. Cardiac output was measured by FloTrac (APCO) and pulmonary arterial catheter-based thermodilution method (ICO) during off-pump coronary artery bypass and resection of pheochromocytoma, procedures associated with hemodynamically unstable conditions. As algorithm is renewed in a new version of the device, the accuracy of the device is improved; bias, precision and limits of agreement decreased; correlation coefficient increased, and percentage error was assessed to be around 30%. On the other hand, there was a tendency for increased negative bias as cardiac output increased, implying APCO tends to underestimate ICO in high CO ranges. APCO is less invasive and could rapidly respond to fast changes of hemodynamic state. FloTrac is expected to become a reliable cardiac output monitoring device even under hemodynamically unstable conditions. Further improvement of the algorithm is anticipated.

  17. Validation of non-invasive arterial pressure monitoring during carotid endarterectomy.

    Science.gov (United States)

    Heusdens, J F; Lof, S; Pennekamp, C W A; Specken-Welleweerd, J C; de Borst, G J; van Klei, W A; van Wolfswinkel, L; Immink, R V

    2016-09-01

    Patients undergoing carotid endarterectomy require strict arterial blood pressure (BP) control to maintain adequate cerebral perfusion. In this study we tested whether non-invasive beat-to-beat Nexfin finger BP (BPfin) can replace invasive beat-to-beat radial artery BP (BPrad) in this setting. In 25 consecutive patients (median age 71 yr) scheduled for carotid endarterectomy and receiving general anaesthesia, BPfin and BPrad were monitored simultaneously and ipsilaterally during the 30-min period surrounding carotid artery cross-clamping. Validation was guided by the standard set by the Association for the Advancement of Medical Instrumentation (AAMI), which considers a BP monitor adequate when bias (precision) is <5 (8) mm Hg, respectively. BPfin vs BPrad bias (precision) was -3.3 (10.8), 6.1 (5.7) and 3.5 (5.2) mm Hg for systolic, diastolic, and mean BP, respectively. One subject was excluded due to a poor quality BP curve. In another subject, mean BPfin overestimated mean BPrad by 13.5 mm Hg. Mean BPfin could be considered as an alternative for mean BPrad during a carotid endarterectomy, based on the AAMI criteria. In 23 of 24 patients, the use of mean BPfin would not lead to decisions to adjust mean BPrad values outside the predefined BP threshold. NCT01451294. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Insulin Micropump with Embedded Pressure Sensors for Failure Detection and Delivery of Accurate Monitoring

    Directory of Open Access Journals (Sweden)

    Dimitry Dumont-Fillon

    2014-11-01

    Full Text Available Improved glycemic control with insulin pump therapy in patients with type 1 diabetes mellitus has shown gradual reductions in nephropathy and retinopathy. More recently, the emerging concept of the artificial pancreas, comprising an insulin pump coupled to a continuous glucose meter and a control algorithm, would become the next major breakthrough in diabetes care. The patient safety and the efficiency of the therapy are directly derived from the delivery accuracy of rapid-acting insulin. For this purpose, a specific precision-oriented design of micropump has been built. The device, made of a stack of three silicon wafers, comprises two check valves and a pumping membrane that is actuated against stop limiters by a piezo actuator. Two membranes comprising piezoresistive strain gauges have been implemented to measure the pressure in the pumping chamber and at the outlet of the pump. Their high sensitivity makes possible the monitoring of the pumping accuracy with a tolerance of ±5% for each individual stroke of 200 nL. The capability of these sensors to monitor priming, reservoir overpressure, reservoir emptying, outlet occlusion and valve leakage has also been studied.

  19. Continuous ventricular cerebrospinal fluid drainage with intracranial pressure monitoring for management of posttraumatic diffuse brain swelling

    Directory of Open Access Journals (Sweden)

    Almir Ferreira de Andrade

    2011-02-01

    Full Text Available BACKGROUND: Ventricular drainage has played an important role in the management of traumatic brain-injured patients. The aim of the present study was describe outcomes in a series of 57 patients with diffuse brain swelling underwent to intracranial pressure (ICP monitoring. METHOD: Fifty-eight patients with diffuse posttraumatic brain swelling, were evaluated prospectively. The Glasgow Coma Scale (GCS scores of patients varied from 4 to 12. Patients groups divided according to GCS and age. Patient neurological assessment was classified as favorable, unfavorable, and death. RESULTS: Mechanisms of injury were vehicle accidents in 72.4% and falls in 15.6%. 54% of patients had GCS scores between 6 and 8. There were no statistical differences, regarding outcome, between groups separated by age. In the adults group (n=47, 44.7% evolved favorably. CONCLUSION: Our results indicate a poor prognosis in patients with brain swelling. We believe that continuous ventricular CSF drainage with ICP monitoring is a simple method as an adjunct in the management of these patients.

  20. Transatrial access for left atrial pressure (LAP) monitoring line placement in arterial switch operation (ASO) in neonates.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Hamid, Mohammad; Amanullah, Muneer; Ahsan, Khalid

    2013-11-01

    Left Atrial pressure monitoring is a useful and accurate method to guide Left ventricle filling in the patients who undergo Arterial switch operation for transposition of great arteries. We have used a different technique in three TGA patients for LA pressure monitoring line placement. After cleaning and draping,right internal jugular vein (rt IJV) located through 22G venous cannula, guide wire was put in followed by sliding the 22G x 8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into LA by the operating surgeon during atrial septum repair. The catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72 hrs. LA pressure monitoring is helpful in anticipating LV dysfunction in ASO.

  1. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.

    NARCIS (Netherlands)

    Hofhuizen, C.M.; Lemson, J.; Hemelaar, A.E.A.; Settels, J.J.; Schraa, O.; Singh, S.K.; Hoeven, J.G. van der; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin device. We assessed

  2. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.

    Science.gov (United States)

    Hofhuizen, C M; Lemson, J; Hemelaar, A E A; Settels, J J; Schraa, O; Singh, S K; van der Hoeven, J G; Scheffer, G J

    2010-10-01

    Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin™ device. We assessed the adequacy of a prototype device (Nexfin-paediatric), designed for a paediatric population, for detecting rapid arterial pressure changes in children during cardiac surgery. Thirteen anaesthetized children with a median age of 11 months (2 months-7 yr) undergoing congenital cardiac surgery were included in the study. reBAP and intra-arterial pressure (IAP) were recorded simultaneously during the surgical procedure. To assess the accuracy of reBAP in tracking arterial pressure changes, the four largest IAP variations within a 5 min time interval were identified from each procedure. These variations were compared offline with reBAP during a 10 s control period before and a 10 s period after an arterial pressure change had occurred. In 10 out of 13 children, a non-invasive arterial pressure recording could be obtained. Therefore, recordings from these 10 children were eligible for further analysis, resulting in 40 data points. The correlation coefficient between reBAP and IAP in tracking mean arterial pressure (MAP) changes was 0.98. reBAP followed changes in IAP with a mean bias for systolic, diastolic arterial pressure, and MAP of 0.0 mm Hg (sd 5.8), 0.1 (sd 2.8), and 0.19 (sd 2.7), respectively. The prototype device closely follows arterial pressure changes in children. However, in a considerable number of attempts, obtaining a signal was time-consuming or unsuccessful. This technique seems promising but requires further technical development.

  3. Partial molar volumes of organic solutes in water. XXIII. Cyclic ketones at T = (298 to 573) K and pressures up to 30 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Cibulka, Ivan, E-mail: ivan.cibulka@vscht.cz [Department of Physical Chemistry, Institute of Chemical Technology, Technicka 5, 166 28 Prague (Czech Republic); Simurka, Lukas; Hnedkovsky, Lubomir [Department of Physical Chemistry, Institute of Chemical Technology, Technicka 5, 166 28 Prague (Czech Republic); Bolotov, Alexander [Butlerov Institute of Chemistry, Kazan Federal University, Kremlevskaya Str. 18, Kazan 420008 (Russian Federation)

    2011-07-15

    Research highlights: > In this study we examine standard molar volumes of aqueous cyclic ketones. > State parameters of measurements were (298 to 573) K and pressures up to 30 MPa. > Differences in behavior of monoketones and cyclohexane-1,4-dione were observed. > Group contribution method was designed and examined. - Abstract: Density data for dilute aqueous solutions of four cyclic ketones (cyclopentanone, cyclohexanone, cycloheptanone, and cyclohexane-1,4-dione) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were close to the saturated vapor pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Contributions of the molecular structural segments (methylene and carbonyl groups) to the standard molar volume were also evaluated and analyzed.

  4. The association of serum gamma-glutamyl transpeptidase level and other laboratory parameters with blood pressure in hypertensive patients under ambulatory blood pressure monitoring

    Directory of Open Access Journals (Sweden)

    Ortakoyluoglu A

    2016-09-01

    Full Text Available Adile Ortakoyluoglu, Betul Boz, Oguzhan Sitki Dizdar, Deniz Avci, Ali Cetinkaya, Osman Baspinar Department of Internal Medicine, Kayseri Training and Research Hospital, Kayseri, Turkey Background: Hypertension is a very important cause of morbidity and mortality. Serum gamma-glutamyl transpeptidase (GGT is a biomarker of oxidative stress and associated with increased risk of hypertension and diabetes. The aim of this study was to evaluate the association of serum GGT level, which is an early marker of inflammation and endothelial dysfunction, with the deterioration of the diurnal rhythm of the blood pressure.Methods: A total of 171 patients with hypertension were included in this study. Patients whose nighttime mean blood pressure, measured via ambulatory blood pressure monitoring, decreased between 10% and 20% compared with the daytime mean blood pressure were defined as “dippers”, whereas patients with a nighttime blood pressure decrease lower than 10% were defined as “non-dippers”.Results: A total of 99 hypertensive patients (65 females/34 males were classified as dippers and 72 patients (48 females/24 males as non-dippers. The mean age of the non-dipper group was significantly greater than the dipper group. Serum GGT, C-reactive protein and uric acid levels were significantly higher among patients in the non-dipper group. Negative correlations were detected between GGT levels and diurnal systolic and diastolic blood pressure decreases.Conclusion: Our findings revealed that GGT level was higher in the non-dipper group, and was negatively correlated with the nighttime decrease of diurnal blood pressure. C-reactive protein and uric acid levels were also higher in the non-dipper group. However, future randomized controlled prospective studies with larger patient populations are necessary to confirm our findings. Keywords: gamma-glutamyl transpeptidase, hypertension, ambulatory blood pressure monitoring, laboratory parameters

  5. Management of patients with severe traumatic brain injury guided by intraventricular intracranial pressure monitoring: a report of 136 cases

    Institute of Scientific and Technical Information of China (English)

    ZENG Tao; GAO Liang

    2010-01-01

    Objective:To evaluate the effect of the treatment modality guided by intraventricular intracranial pressure (ICP) monitoring on patients with severe traumatic brain injury (TBI).Methods:The clinical data of a group of 136 severely brain-injured patients admitted to Shanghai Neurosurgical Emergency Center from December 2004 to February 2006 were studied.Results:The intraventricular ICP monitor was placed in all the 136 patients via Kocher's pathway, Paine's pathway or intraoperative opened ventricle. In this series, the probe was placed during the procedure of craniotomy in 98 patients; for other 38 patients, the probe was placed initially to measure or to monitor ICE A stepwise protocol targeting at ICP control (≤20 mm Hg) and optimal cerebral perfusion pressure (CPP) maintenance (60-90 mm Hg) was deployed.Among them, 76 patients survived with good recovery, 14 with moderate disability, 24 with severe disability, 10 with vegetative state, and 12 died. Complications associated with intraventricular ICP monitoring included hemorrhage and infection. Hemorrhage occurred in 1 patient and infection in 5 patients. There were no unacceptable complications related to ICP monitoring.Conclusions:Ventricular access for ICP monitoring can be safely and accurately achieved. ICP monitoring via ventriculostomy may facilitate an early and accurate intervention for severely brain-injured patients. The intraventricular ICP monitoring is a low-risk procedure and can yield great benefits for management of patients with severe TBI.

  6. Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: the impact of posture.

    Science.gov (United States)

    Muehlsteff, J; Aubert, X A; Morren, G

    2008-01-01

    There is an unmet need for cuff-less blood pressure (BP) monitoring especially, in personal healthcare applications. The pulse arrival time (PAT) approach might offer a suitable solution to enable comfortable BP monitoring even at beat-level. However, the methodology is based on hemodynamic surrogate measures, which are sensitive to patient activities such as posture changes, not necessarily related to blood pressure variations. In this paper, we analyze the impact of posture on the PAT measure and related hemodynamic parameters such as the pre-ejection period in well-defined procedures. Additionally, the PAT of a monitored subject is investigated in an unsupervised scenario illustrating the complexity of such a measurement. Our results show the failure of blood pressure inference based on simple calibration strategies using the PAT measure only. We discuss opportunities to compensate for the observed effects towards the realization of wearable cuff-less blood pressure monitoring. These findings emphasize the importance of accessing context information in personal healthcare applications, where vital sign monitoring is typically unsupervised.

  7. Influence of Partial Pressure of Sulfur and Oxygen on Distribution of Fe and Mn between Liquid Fe-Mn Oxysulfide and Molten Slag

    Science.gov (United States)

    Kim, Sun-Joong; Shibata, Hiroyuki; Takekawa, Jun; Kitamura, Shin-Ya; Yamaguchi, Katsunori; Kang, Youn-Bae

    2012-10-01

    The authors proposed an innovative process for recovering Mn from steelmaking slag. The process starts with the sulfurization of steelmaking slag to separate P from Mn by the formation of a liquid sulfide phase (matte). Then, the obtained matte is weakly oxidized to make a Mn-rich oxide phase without P. High-purity Fe-Mn alloys can therefore be produced by the reduction of the Mn-rich oxide phase. However, to the authors' knowledge, the sulfurization of molten slag containing P and Mn has not been sufficiently investigated. It was recently found that P was not distributed to the matte in equilibrium with the molten slag. To gain knowledge of the process's development, it is important to investigate the influence of the partial pressures of sulfur and oxygen on the equilibrium distribution of Mn and Fe between the matte and the molten slag. In the current work, a mineralogical microstructure analysis of the matte revealed that the existence of the oxysulfide and metal phases was dependent on the partial pressure of sulfur and oxygen. The Mn content of the matte increased with partial pressure of sulfur while the O content of the matte decreased. In contrast, the ratio of Mn/Fe in the matte was constant when the metal phase of the matte was observed at a log P_{{{{O}}2 }} below -11. These results also corresponded to the relationship between the activity coefficient ratio of MnS/FeS and the mole fraction of MnS/FeS in the matte. The γ MnS/ γ FeS value decreased exponentially as the mole fraction of MnS/FeS increased.

  8. An investigation on the effect of high partial pressure of hydrogen on the nanocrystalline structure of silicon carbide thin films prepared by radio-frequency magnetron sputtering.

    Science.gov (United States)

    Daouahi, Mohsen; Omri, Mourad; Kerm, Abdul Ghani Yousseph; Al-Agel, Faisal Abdulaziz; Rekik, Najeh

    2015-02-01

    The aim of the study reported in this paper is to investigate the role of the high partial pressure of hydrogen introduced during the growth of nanocrystalline silicon carbide thin films (nc-SiC:H). For this purpose, we report the preparation as well as spectroscopic studies of four series of nc-SiC:H obtained by radio-frequency magnetron sputtering at high partial pressure of hydrogen by varying the percentage of H2 in the gas mixture from 70% to 100% at common substrate temperature (TS=500°C). The effects of the dilution on the structural changes and the chemical bonding of the different series have been studied using Fourier transform infrared and Raman spectroscopy. For this range of hydrogen dilution, two groups of films were obtained. The first group is characterized by the dominance of the crystalline phase and the second by a dominance of the amorphous phase. This result confirms the multiphase structure of the grown nc-SiC:H thin films by the coexistence of the SiC network, carbon-like and silicon-like clusters. Furthermore, infrared results show that the SiC bond is the dominant absorption peak and the carbon atom is preferentially bonded to silicon. The maximum value obtained of the crystalline fraction is about 77%, which is relatively important compared to other results obtained by other techniques. In addition, the concentration of CHn bonds was found to be lower than that of SiHn for all series. Raman measurements revealed that the crystallization occurs in all series even at 100% H2 dilution suggesting that high partial pressure of hydrogen favors the formation of silicon nanocrystallites (nc-Si). The absence of both the longitudinal acoustic band and the transverse optical band indicate that the crystalline phase is dominant.

  9. Chronobiology of arterial hypertension in hemodialysis patients: implications for home blood pressure monitoring.

    Science.gov (United States)

    Agarwal, Rajiv; Light, Robert P

    2009-10-01

    Hemodialysis patients have a steady increase in blood pressure (BP) during the 44-hour interdialytic interval when ambulatory BP monitoring is used. Home BP recording allows for a longer period of monitoring between dialysis treatments and may better define the chronobiological characteristics of arterial hypertension. This study sought to determine the optimal time to perform home BP monitoring in hemodialysis patients to improve the strength of prediction of 44-hour interdialytic ambulatory BP. Diagnostic test study. This is an ancillary analysis of patients participating in the Dry-weight Reduction in Hypertensive Hemodialysis Patients (DRIP) trial. Home BP measured 3 times daily for 1 week by using a validated oscillometric monitor on 3 occasions at 4-week intervals after randomization. Home BP measured during the first third, second third, and last third of time elapsed after the dialysis treatment, as well as each third of the dialysis treatment, was compared with the overall ambulatory BP. Interdialytic ambulatory BP measured on 3 occasions at 4-week intervals after randomization. During the interdialytic interval, we found an increase in systolic ambulatory BP of 0.30 +/- 0.36 mm Hg/h and an increase in systolic home BP of 0.40 +/- 0.25 mm Hg/h. This relationship in home BP reached a plateau after approximately 48 hours. A similar pattern was seen for diastolic home BP. Probing dry weight steepened the slope of ambulatory BP, but did not alter the time-dependent relationship of home BP. Home BP was on average higher (bias) by 14.1 (95% confidence interval, 12.0 to 16.2)/5.7 mm Hg (95% confidence interval, 4.6 to 6.9). The SD of differences between methods (precision) was 4.6/2.8 mm Hg. Measurement of BP during each third of the interdialytic interval gave the best precision, measured by using model fit compared with ambulatory BP measurements. Our cohort was overrepresented by African American hemodialysis patients. Whether African American participants

  10. The solubility of carbon monoxide and hydrogen in water and sea-water at partial pressures of about 10?5 atmospheres

    OpenAIRE

    Schmidt, Ulrich

    2011-01-01

    A new technique was used to measure the Bunsen solubility coefficients of CO and H2 in deionized water and artificial sea-water in the temperature range from 0° to 30 °C. The partial pressure of the respective gas was less than 2 × 10?5 atmospheres. Within 10% the results compare rather well with solubility data from the literature, which were obtained from measurements applying pure CO and H2 in the gaseous phase.DOI: 10.1111/j.2153-3490.1979.tb00883.x

  11. Effect of oxygen partial pressure on structural and optical properties of pulsed laser deposited CaBi4Ti4O15 thin films

    Science.gov (United States)

    Emani, Sivanagi Reddy; Raju, K. C. James

    2017-03-01

    The influence of oxygen partial pressure (OPP) on the structural and optical properties of CaBi4Ti4O15 (CBTi) thin films deposited by pulsed laser deposition have been investigated in the range of 0.1 mbar to 7.8 × 10-3 mbar. The structural properties show all the films are polycystlline in nature with orthorombic structure. The optical transmission of the films is in the range of 60-90%. A slight shift in transmission threshold towards higher wavelength region with an increase in O2 pressure reveals the systematic reduction in the optical band gap energy (3.69 to 3.59 eV) of the films. Raman studies confirm the phase formation and presence of stresses in the films. It is suggested that the OPP played a key role in controlling crystallinity, morphology, chemical composition and optical properties in CBTi thin films.

  12. Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery.

    Science.gov (United States)

    Kumar, G Anil; Jagadeesh, A M; Singh, Naveen G; Prasad, S R

    2015-01-01

    Continuous arterial pressure monitoring is essential in cardiac surgical patients during induction of general anaesthesia (GA). Continuous non-invasive arterial pressure (CNAP) monitoring is fast gaining importance due to complications associated with the invasive arterial monitoring. Recently, a new continuous non-invasive arterial pressure device (CNAP™) has been validated perioperatively in non-cardiac surgeries. The aim of our study is to compare and assess the performance of CNAP during GA with invasive arterial pressure (IAP) in patients undergoing cardiac surgeries. Sixty patients undergoing cardiac surgery were included. Systolic, diastolic, and mean arterial pressure (MAP) data were recorded every minute for 20 min simultaneously for both IAP and CNAP™. Statistical analysis was performed using mountain plot and Bland Altman plots for assessing limits of agreement and bias (accuracy) calculation. Totally 1200 pairs of data were analysed. The CNAP™ systolic, diastolic and MAP bias was 5.98 mm Hg, -3.72 mm Hg, and - 0.02 mm Hg respectively. Percentage within limits of agreement was 96.0%, 95.2% and 95.7% for systolic, diastolic and MAP. The mountain plot showed similar results as the Bland Altman plots. We conclude CNAP™ provides real-time estimates of arterial pressure comparable to IAP during induction of GA for cardiac surgery. We recommend CNAP can be used as an alternative to IAP in situations such as cardiac patients coming for non-cardiac surgeries, cardiac catheterization procedures, positive Allen's test, inability to cannulate radial artery and vascular diseases, where continuous blood pressure monitoring is required.

  13. Evaluation of the Colin STBP-680 at rest and during exercise: an automated blood pressure monitor using R-wave gating.

    OpenAIRE

    Bond, V.; Bassett, D R; Howley, E T; Lewis, J.; Walker, A J; Swan, P D; Tearney, R J; Adams, R.G.

    1993-01-01

    The application of automated blood pressure measurement during exercise has been limited by inaccuracies introduced by the effects of accompanying motion and noise. We evaluated a newly developed automated blood pressure monitor for measuring exercise blood pressure (Colin STBP-680; Colin, San Antonio, Texas, USA). The STBP-680 uses acoustic transduction with the assistance of the electrocardiogram R-wave to trigger the sampling period for blood pressure measurement. The automated monitor rea...

  14. Intensive care management of head injury patients without routine intracranial pressure monitoring

    Directory of Open Access Journals (Sweden)

    Santhanam R

    2007-01-01

    Full Text Available Background: Head injury contributes significantly to mortality and morbidity in India. Evaluation of the available trauma care facilities may help improve outcome. Aim: To evaluate the factors influencing the mortality of patients with head injury who had intensive care management and evolve strategies to improve outcome. Setting and Design: Retrospective study in a tertiary hospital where intracranial pressure monitoring (ICPM is not routinely practiced. Materials and Methods: All patients with head injury managed in the intensive care unit in a two-year period were included. The factors evaluated were age, vital signs, Glasgow Coma scale score (GCS at admission, pupillary light reflex (PR, oculocephalic reflex (OCR, hemodynamic stability, computerized tomography (CT findings, diabetes mellitus, anemia, infections and abnormalities of serum sodium. Results: We analyzed 208 patients (202 without ICPM. In-hospital mortality was 64 (31%. Only 24 (11.5% patients were admitted within one hour of injury, while one-third arrived after six hours. The clinical factors (at admission that influenced mortality included age, GCS, PR, OCR and diastolic blood pressure (DBP. Effacement of the basal cisterns in the initial and repeat CT scans, hyperglycemia, hemodynamic instability and serum sodium imbalances were associated with higher mortality. The independent predictors of mortality by logistic regression were initial GCS, DBP, hemodynamic instability and effacement of cisterns on repeat CT. Conclusions: Mortality following head injury is high. Pre-hospital emergency medical services are disorganized. The key to reducing mortality within the limitations of our current trauma system is maintenance of DBP>70 mmHg and SBP> 90 mmHg from the time of first contact.

  15. European Society of Hypertension position paper on ambulatory blood pressure monitoring.

    Science.gov (United States)

    O'Brien, Eoin; Parati, Gianfranco; Stergiou, George; Asmar, Roland; Beilin, Laurie; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M; Shennan, Andrew; Staessen, Jan A; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2013-09-01

    Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.

  16. Ambulatory blood pressure monitoring and endothelium-dependent vasodilation in the elderly athletes.

    Science.gov (United States)

    Galetta, F; Franzoni, F; Plantinga, Y; Ghiadoni, L; Rossi, M; Prattichizzo, F; Carpi, A; Taddei, S; Santoro, G

    2006-09-01

    Regular exercise is a key component of cardiovascular risk prevention strategies, because it is associated with a variety of beneficial metabolic and vascular effects that reduce mortality and the incidence of cardiovascular adverse events. Endothelium plays an important role in the local regulation of vascular tone and structure, mainly by nitric oxide (NO) synthesis and action. Aim of the present study was to evaluate in elderly athletes the effect of regular aerobic exercise on arterial blood pressure (BP) and on endothelium-dependent flow-mediated dilation (FMD) of the brachial artery. The study population included 30 male subjects (mean age 65.6+/-5.6 years), who had practiced endurance running at a competitive level for at least 40 years, and 28 age- and sex-matched subjects (mean age 64.5+/-4.5 years) with sedentary lifestyle and free of cardiovascular disease. Athletes and control subjects underwent standard 12-lead ECG, clinic BP, 24-h ambulatory BP monitoring and endothelium-dependent FMD and endothelium-independent response to glyceryl trinitrate (GTN), 400 microg, in the brachial artery by high-resolution ultrasonography. Systolic clinic and ambulatory 24-h BP were significantly lower in the athletes, than in the controls (Pathletes (Pathletes also had a lower 24-h, day-time and night-time heart rate (HR) (Pathletes (Pathletes showed higher FMD than elderly sedentary subjects (Pphysical activity can counteract the age-related endothelial dysfunction that characterizes sedentary aging, preserving the capacity of the endothelium-dependent vasodilation and reduces BP values improving arterial pressure control.

  17. Noninvasive intracranial pressure monitoring via optic nerve sheath diameter for robotic surgery in steep Trendelenburg position

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2015-01-01

    Full Text Available Background: Recent reports of increased intracranial pressure (ICP due to steep Trendelenburg (ST position causing neurological deterioration, decreased regional cerebral oxygen saturation and postoperative visual loss after robotic urological and gynecological surgeries led us to consider a simple technique of ICP monitoring. Ours is one of the first instances reported of quantitative noninvasive measurement of increase in ICP with ST position by serial measurement of binocular optic nerve sheath diameter (ONSD in patients undergoing robot assisted urological and gynecological oncosurgery. We tested whether ONSD values rose to above the upper limits of normal and for what length of time they remained elevated. Materials and Methods: Prospective, randomized, interventional, parallel group, active control study conducted on 252 American Society of Anesthesiologists I and II patients. ONSD was measured using 7.5 MHz linear ultrasound probe in supine and Trendelenburg positions. Statistics: Student′s t-test to compare the inter-group mean ONSD and the repetitive t-test for intra-group analysis. Result: Comparison of the mean ONSD values of both groups yielded a 2-tailed significance P <0.01 at all compared time points intra- and post-operatively. In Group-O (open surgery; supine position, the baseline mean bilateral ONSD was 4.36 mm, which did not show any statistically significant change throughout open surgery and postoperative period. On de-docking the robot, 6.2 mm was the mean ONSD value in Group-R (robotic group while 4.3 mm was the corresponding value in control Group-O. Conclusion: ONSD evaluation is a simple, quick, safe, readily available, reliable, cost effective, noninvasive, potential standard of care for screening and monitoring of patients undergoing robotic surgery in ST position.

  18. The tympanic membrane displacement analyser for monitoring intracranial pressure in children.

    Science.gov (United States)

    Gwer, Samson; Sheward, Victoria; Birch, Anthony; Marchbanks, Robert; Idro, Richard; Newton, Charles R; Kirkham, Fenella J; Lin, Jean-Pierre; Lim, Ming

    2013-06-01

    Raised intracranial pressure (ICP) is a potentially treatable cause of morbidity and mortality but tools for monitoring are invasive. We sought to investigate the utility of the tympanic membrane displacement (TMD) analyser for non-invasive measurement of ICP in children. We made TMD observations on normal and acutely comatose children presenting to Kilifi District Hospital (KDH) at the rural coast of Kenya and on children on follow-up for idiopathic intracranial hypertension at Evelina Children's Hospital (ECH), in London, UK. We recruited 63 patients (median age 3.3 (inter-quartile range (IQR) 2.0-4.3) years) at KDH and 14 children (median age 10 (IQR 5-11) years) at ECH. We observed significantly higher (more negative) TMD measurements in KDH children presenting with coma compared to normal children seen at the hospital's outpatient department, in both semi-recumbent [mean -61.3 (95 % confidence interval (95 % CI) -93.5 to 29.1) nl versus mean -7.1 (95 % CI -54.0 to 68.3) nl, respectively; P = 0.03] and recumbent postures [mean -61.4 (95 % CI -93.4 to -29.3) nl, n = 59) versus mean -25.9 (95 % CI -71.4 to 123.2) nl, respectively; P = 0.03]. We also observed higher TMD measurements in ECH children with raised ICP measurements, as indicated by lumbar puncture manometry, compared to those with normal ICP, in both semi-recumbent [mean -259.3 (95 % CI -363.8 to -154.8) nl versus mean 26.7 (95 % CI -52.3 to 105.7) nl, respectively; P analyser has a potential utility in monitoring ICP in a variety of clinical circumstances.

  19. The test research on partial relieving pressure for the entry in the deep mine under high stress and friable surrounding rock

    Institute of Scientific and Technical Information of China (English)

    DU Ji-ping; HOU Chao-jiong; ZHU Ya-ping; HAO Ming-kui

    2007-01-01

    Based on the geological condition of Zhangxiaolou deep mine in Xuzhou mining area, under 986 m in depth, 20.6~31.6 MPa in maximum horizontal principal stress, and friable and fractured surrounding rock, test researches on partial relieving pressure were completed for the entry with U-steel arched yielding support. The relieving pressure parameters, technology process and results of springing blasting by boreholes and excavating pockets in the two sides of entry were introduced. It is demonstrated that springing will not be shaped under the condition of single borehole arrangement after exploded, the arrangement by a group, it will make borehole bottom form springing in 0.6~0.8 m in diameter, that convergence of two sides and roof to floor have some increments by using springing blasting for reliving pressure. This kind of method for reliving pressure is not suitable to use in the deep mine, and that the convergence of two sides obviously declined by excavating pocket in two sides, it can be still used in the entry with metal support, while maintenance of entry in deep mines is difficult, and can not be supported by bolt or bolt with wire mesh.

  20. Core burnup calculation and accidents analyses of a pressurized water reactor partially loaded with rock-like oxide fuel

    Science.gov (United States)

    Akie, H.; Sugo, Y.; Okawa, R.

    2003-06-01

    A rock-like oxide (ROX) fuel - light water reactor (LWR) burning system has been studied for efficient plutonium transmutation. For the improvement of small negative reactivity coefficients and severe transient behaviors of ROX fueled LWRs, a partial loading core of ROX fuel assemblies with conventional UO 2 assemblies was considered. As a result, although the reactivity coefficients could be improved, the power peaking tends to be large in this heterogeneous core configuration. The reactivity initiated accident (RIA) and loss of coolant accident (LOCA) behaviors were not sufficiently improved. In order to reduce the power peaking, the fuel composition and the assembly design of the ROX fuel were modified. Firstly, erbium burnable poison was added as Er 2O 3 in the ROX fuel to reduce the burnup reactivity swing. Then pin-by-pin Pu enrichment and Er content distributions within the ROX fuel assembly were considered. In addition, the Er content distribution was also considered in the axial direction of the ROX fuel pin. With these modifications, a power peaking factor even lower than the one in a conventional UO 2 fueled core can be obtained. The RIA and LOCA analyses of the modified core have also shown the comparable transient behaviors of ROX partial loading core to those of the UO 2 core.

  1. Analysis of the Pressure Rise in a Partially Filled Liquid Tank in Microgravity with Low Wall Heat Flux and Simultaneous Boiling and Condensation

    Science.gov (United States)

    Hasan, Mohammad M.; Balasubramaniam, R.

    2012-01-01

    Experiments performed with Freon 113 in the space shuttle have shown that in a pro- cess of very slow heating, high liquid superheats can be sustained for a long period in microgravity. In a closed system explosive vaporization of superheated liquid resulted in pressure spikes of varying magnitudes. In this paper, we analyze the pressure rise in a partially lled closed tank in which a large vapor bubble (i.e., ullage) is initially present, and the liquid is subjected to a low wall heat ux. The liquid layer adjacent to the wall becomes superheated until the temperature for nucleation of the bubbles (or the incipience of boiling) is achieved. In the absence of the gravity-induced convection large quantities of superheated liquid can accumulate over time near the heated surface. Once the incipience temperature is attained, explosive boiling occurs and the vapor bubbles that are produced on the heater surface tend to quickly raise the tank pressure. The liquid-vapor saturation temperature increases as well. These two e ects tend to induce condensation of the large ullage bubble that is initially present, and tends to mitigate the tank pressure rise. As a result, the tank pressure is predicted to rise sharply, attain a maximum, and subsequently decay slowly. The predicted pressure rise is compared with experimental results obtained in the microgravity environments of the space shuttle for Freon 113. The analysis is appli- cable, in general to heating of liquid in closed containers in microgravity and to cryogenic fuel tanks, in particular where small heat leaks into the tank are unavoidable.

  2. [Anesthesia management of geriatric patients with arterial pressure-based cardiac output monitoring FloTrac sensor for emergency surgery].

    Science.gov (United States)

    Yamamoto, Shunsuke; Goto, Koji; Yasuda, Norihisa; Kusaka, Junya; Hidaka, Seigo; Miyakawa, Hiroshi; Noguchi, Takayuki

    2009-06-01

    In cases of emergency surgery for geriatric patients, immediate anesthesia induction and careful intraoperative management is necessary without sufficient preoperative information. We report anesthesia management of a 96-year and a 90-year old patients with FloTrac sensor which is an arterial pressure-based cardiac output monitoring device and is able to manage critical patients effectively and safely during anesthesia.

  3. 空间站泄漏监测报警方案设想——绝压法%Assumption on Leak Monitoring and Alarming for Space Station --Absolute Pressure Leak Detection

    Institute of Scientific and Technical Information of China (English)

    回天力; 刘刚; 高静; 贾东永; 杨纯; 孙国辉

    2012-01-01

    介绍了各国空间站泄漏监测技术的背景及绝压法泄漏监测的原理,在分析空间站舱体内、外环境的基础上提出了空间站泄漏监测报警模式,及通过测量舱内氮分压进行泄漏监测的技术方案,提出了"反应时间占用率"的概念并以此作为评判监测报警效果的依据,最终对比得出氮分压间接监测法可作为有航天员值守期间空间站的泄漏监测与报警方案。%The background of space station leak monitoring technology and the principle of absolute pressure leak detection are introduced. Based on the analysis of internal and external environment of space station cabin, the monitoring and alarming mode for leak detection is proposed, and the technical scheme of leak monitoring by measuring the partial pressure of nitrogen in the cabin is also introduced. The concept of "Occupation Ratio of Response Time" is put for- ward and taken as a basis for judging the effect of monitoring and alarming. It is concluded that the indirect monitoring method by measuring the partial pressure of nitrogen can be used as a leak monitoring and alarming method when the space station is tended by astronauts.

  4. Oxygen partial pressure dependence of surface space charge formation in donor-doped SrTiO3

    Science.gov (United States)

    Andrä, Michael; Dvořák, Filip; Vorokhta, Mykhailo; Nemšák, Slavomír; Matolín, Vladimír; Schneider, Claus M.; Dittmann, Regina; Gunkel, Felix; Mueller, David N.; Waser, Rainer

    2017-05-01

    In this study, we investigated the electronic surface structure of donor-doped strontium titanate. Homoepitaxial 0.5 wt. % donor-doped SrTiO3 thin films were analyzed by in situ near ambient pressure X-ray photoelectron spectroscopy at a temperature of 770 K and oxygen pressures up to 5 mbar. Upon exposure to an oxygen atmosphere at elevated temperatures, we observed a rigid binding energy shift of up to 0.6 eV towards lower binding energies with respect to vacuum conditions for all SrTiO3 core level peaks and the valence band maximum with increasing oxygen pressure. The rigid shift is attributed to a relative shift of the Fermi energy towards the valence band concomitant with a negative charge accumulation at the surface, resulting in a compensating electron depletion layer in the near surface region. Charge trapping effects solely based on carbon contaminants are unlikely due to their irreversible desorption under the given experimental conditions. In addition, simple reoxygenation of oxygen vacancies can be ruled out as the high niobium dopant concentration dominates the electronic properties of the material. Instead, the negative surface charge may be provided by the formation of cation vacancies or the formation of charged oxygen adsorbates at the surface. Our results clearly indicate a pO2-dependent surface space charge formation in donor-doped SrTiO3 in oxidizing conditions.

  5. Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study.

    Science.gov (United States)

    Jacq, Gwenaëlle; Gritti, Karine; Carré, Cécile; Fleury, Nadège; Lang, Annie; Courau-Courtois, Josette; Bedos, Jean-Pierre; Legriel, Stephane

    2015-09-01

    Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B-E) of transducer level, catheter access site, and patient position were compared with a reference combination (A) (A: patient supine with all catheters in the same plane and a single transducer level (M) for zero point reference (Z) aligned on the phlebostatic axis; B: 45° head-of-bed elevation with M and Z aligned on the phlebostatic axis; C: 45° head-of-bed elevation with M aligned on the catheter access site and Z on the phlebostatic axis; D: 45° head-of-bed elevation with M and Z aligned on the catheter access site; and E: 45° head-of-bed elevation with M aligned on the phlebostatic axis and Z on the catheter access site). We included 103 patients, 68 men and 35 women, with a median age of 69 years (interquartile range [IQR], 56-78); at inclusion, 91 (88.3%) received mechanical ventilation, 45 (43.7%) catecholamines, and 66 (64.1%) sedation. The IAPM access site was femoral in 49 (47.6%) and radial in 54 (52.4%) patients, with 62 of 103 (60.2%) catheters on the right side. Measured absolute mean arterial pressure values were significantly higher with 3 study combinations (C-E) than with the reference combination (A). After adjustment, the differences versus A (median, 83 [IQR, 74-92] mm Hg) remained significant for D (median, 91 [IQR, 85-100] mm Hg, P arterial pressure values. For patients in the 45° head-of-bed elevation position, aligning the Z on the phlebostatic axis provides values that are not significantly different from those obtained using the reference supine modality.