WorldWideScience

Sample records for monitor operations manual

  1. TOKM hardware operation manual

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, H.O.; Halbig, J.K.; Klosterbuer, S.F.; Bosler, G.E. [Los Alamos National Lab., NM (United States); Abedin-Zadeh, R.; Syed-Azmi, B. [International Atomic Energy Agency, Wagramerstrasse, Vienna (Austria)

    1995-08-01

    This manual describes the detector design features, performance, and operating characteristics of the Tokai-1 spent fuel monitor. The system includes a pair of monitors-one for the primary (normal) fuel transfer chute and one for the by-pass fuel transfer chute. Each monitor contains four independent detector tubes to provide direction of travel and redundancy. There are two ion chambers and two {sup 3}He tubes inside each detector package. All of the detectors are used to monitor the presence of spent-fuel gamma rays as the fuel rods pass alongside the detector package. Gamma-ray and neutron detector (GRAND) electronics supply power to the ion chambers and {sup 3}He tubes, and the data is collected in the GRAND and the Kontron computer. The system is designed to operate unattended with data pickup by the inspectors on a 90-day period. This manual gives the performance and calibration parameters.

  2. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  3. FRMAC Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Frandsen, K.

    2010-05-01

    In the event of a major radiological incident, the Federal Radiological Monitoring and Assessment Center (FRMAC) will coordinate the federal agencies that have various statutory responsibilities. The FRMAC is responsible for coordinating all environmental radiological monitoring, sampling, and assessment activities for the response. This manual describes the FRMAC’s response activities in a radiological incident. It also outlines how FRMAC fits in the National Incident Management System (NIMS) under the National Response Framework (NRF) and describes the federal assets and subsequent operational activities which provide federal radiological monitoring and assessment of the affected areas. In the event of a potential or existing major radiological incident, the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) is responsible for establishing and managing the FRMAC during the initial phases.

  4. Water Quality Monitoring Manual.

    Science.gov (United States)

    Mason, Fred J.; Houdart, Joseph F.

    This manual is designed for students involved in environmental education programs dealing with water pollution problems. By establishing a network of Environmental Monitoring Stations within the educational system, four steps toward the prevention, control, and abatement of water pollution are proposed. (1) Train students to recognize, monitor,…

  5. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  6. Intelligence Operations Manual

    Directory of Open Access Journals (Sweden)

    Karla Andrade

    2016-02-01

    Full Text Available This Manual was an important document for the development of intelligence units in El Salvador´s police. It is a guiding document for intelligence operations where relevant aspects on overall information management are detailed.

  7. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  8. Nuclear material operations manual

    Energy Technology Data Exchange (ETDEWEB)

    Tyler, R.P.

    1981-02-01

    This manual provides a concise and comprehensive documentation of the operating procedures currently practiced at Sandia National Laboratories with regard to the management, control, and accountability of nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion.

  9. CHRPR Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Windsor, Bradford T.; Woodring, Mitchell L.; Myjak, Mitchell J.

    2012-08-21

    1.0 Overview The TSA systems VM-250AGN portal monitor is a set of two pillars made to detect nuclear material in a vehicle. Each pillar contains two polyvinyl toluene (PVT) plastic gamma ray detectors and four 3He neutron detectors, as well as a power supply and electronics to process the output from these detectors. Pacific Northwest National Laboratory has designed and built a continuous high-resolution PVT readout (CHRPR) for the TSA portal to allow spectral readout from the gamma and neutron detectors. The CHRPR helps differentiate between different types of radioactive material through increased spectroscopic capability and associated developments. The TSA VM-250AGN continually monitors the natural neutron and gamma ray background which occurs around the pillars. When the system is installed, the two pillars are placed on either side of a roadway, and a vehicle presence sensor records the passage of cars between them. When radiation measurements exceed a preset alarm threshold, the system alarms to let the user know that a radioactive material is present. Time-stamped measurements are continually sent to a computer, where they can be recorded via a Windows terminal or the TSA RAVEN software. For each pillar in the original TSA model, output from each detector is amplified and shaped by a single channel analyzer, the SCA-775. Information from both SCA-775’s are passed to the SC-770 in the master pillar. This is the detector interface module and main data processor. It counts electrical pulses and uses program software to output total readings to the computer, as well as trigger any appropriate alarms. The CHRPR allows a parallel approach to recording radiation readings from the TSA system. After installing the CHRPR system, all TSA power and signal connections are unchanged. The CHRPR captures electrical pulses containing detector and occupancy sensor information from the SCA-775 on either side. These pulses are converted to a signal with a time width

  10. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Passell, Howard D.; Barber, David S.; Betsill, J. David; Littlfield, Adriane C.; Mohagheghi, Amir H.; Shanks, Sonoya T.; Yuldashev, Bekhzad; Salikhbaev, Umar; Radyuk, Raisa; Djuraev, Akram; Djuraev, Amwar; Vasilev, Ivan; Tolongutov, Bajgabyl; Valentina, Alekhina; Solodukhin, Vladimir; Pozniak, Victor

    2002-04-02

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concerns in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.

  11. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  12. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  13. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  14. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual operating table and accessories and manual... Surgical Devices § 878.4950 Manual operating table and accessories and manual operating chair and accessories. (a) Identification. A manual operating table and accessories and a manual operating chair...

  15. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2005-06-13

    This procedure provides instructions for assembling the CH Packaging Drum payload assembly, Standard Waste Box (SWB) assembly, Abnormal Operations and ICV and OCV Preshipment Leakage Rate Tests on the packaging seals, using a nondestructive Helium (He) Leak Test.

  16. 46 CFR 134.170 - Operating manual.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Operating manual. 134.170 Section 134.170 Shipping COAST... LIFTBOATS § 134.170 Operating manual. (a) Each liftboat must have aboard an operating manual approved by the Coast Guard as complying with this section. (b) The operating manual must be available to, and...

  17. 25 CFR 175.5 - Operations manual.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Operations manual. 175.5 Section 175.5 Indians BUREAU OF... Provisions § 175.5 Operations manual. (a) The Area Director shall establish an operations manual for the... Director shall amend the operations manual as needed. (b) The public shall be notified by the Area...

  18. 46 CFR 109.121 - Operating manual.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Operating manual. 109.121 Section 109.121 Shipping COAST... § 109.121 Operating manual. (a) Each unit must have on board an operating manual approved by the Coast Guard as meeting the requirements of this section. (b) The operating manual must be available to,...

  19. Operations (Field Manual)

    Science.gov (United States)

    2008-02-27

    ability to learn and adapt. German Field Marshal Erwin Rommel observed that American Soldiers were initially inexperienced but learned and adapted...quickly and well. Even though the Army is much more experienced than it was in North Africa in World War II, today’s complex environment requires or...strategic distance include the 1942 invasion of North Africa and the 1992 intervention in Somalia. These operations involved forces projected from the

  20. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2009-05-27

    This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-Gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing Shielded Container Payload Assembly; 1.7, Preparing SWB Payload Assembly; and 1.8, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence, except as noted.

  1. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2008-09-11

    This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing SWB Payload Assembly; and 1.7, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed. Transport trailer operations, package loading and unloading from transport trailers, hoisting and rigging activities such as ACGLF operations, equipment checkout and shutdown, and component inspection activities must be performed, but may be performed in any order and in parallel with other activities as long as radiological control steps are not bypassed. Steps involving OCA/ICV lid removal/installation and payload removal/loading may be performed in parallel if there are multiple operators working on the same packaging. Steps involving removal/installation of OCV/ICV upper and lower main O-rings must be performed in sequence.

  2. COE1 Calorimeter Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-15

    The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

  3. RH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2003-09-17

    This procedure provides operating instructions for the RH-TRU 72-B Road Cask, Waste Shipping Package. In this document, ''Packaging'' refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). ''Package'' refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Loading of the RH 72-B cask can be done two ways, on the RH cask trailer in the vertical position or by removing the cask from the trailer and loading it in a facility designed for remote-handling (RH). Before loading the 72-B cask, loading procedures and changes to the loading procedures for the 72-B cask must be sent to CBFO at sitedocuments@wipp.ws for approval.

  4. 46 CFR 197.420 - Operations manual.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Operations manual. 197.420 Section 197.420 Shipping... GENERAL PROVISIONS Commercial Diving Operations Operations § 197.420 Operations manual. (a) The diving supervisor shall— (1) Provide an operations manual to the person-in-charge prior to commencement of...

  5. 33 CFR 127.1305 - Operations Manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operations Manual. 127.1305... Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1305 Operations Manual. Each Operations Manual must contain— (a) A description of each liquid-transfer system and vapor transfer...

  6. 33 CFR 385.28 - Operating Manuals.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Operating Manuals. 385.28 Section... Processes § 385.28 Operating Manuals. (a) General provisions. (1) The Corps of Engineers and the non-Federal..., develop Operating Manuals to ensure that the goals and purposes of the Plan are achieved. (2)...

  7. 33 CFR 127.305 - Operations Manual.

    Science.gov (United States)

    2010-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.305 Operations Manual. Each...

  8. Regional Test Center Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    The U.S. DOE Regional Test Center for Solar Technologies program was established to validate photovoltaic (PV) technologies installed in a range of different climates. The program is funded by the Energy Department's SunShot Initiative. The initiative seeks to make solar energy cost competitive with other forms of electricity by the end of the decade. Sandia National Laboratory currently manages four different sites across the country. The National Renewable Energy Laboratory manages a fifth site in Colorado. The entire PV portfolio currently includes 20 industry partners and almost 500 kW of installed systems. The program follows a defined process that outlines tasks, milestones, agreements, and deliverables. The process is broken out into four main parts: 1) planning and design, 2) installation, 3) operations, and 4) decommissioning. This operations manual defines the various elements of each part.

  9. Operating manual for the Bulk Shielding Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1987-03-01

    The BSR is a pool-type reactor. It has the capabilities of continuous operation at a power level of 2 MW or at any desired lower power level. This manual presents descriptive and operational information. The reactor and its auxiliary facilities are described from physical and operational viewpoints. Detailed operating procedures are included which are applicable from source-level startup to full-power operation. Also included are procedures relative to the safety of personnel and equipment in the areas of experiments, radiation and contamination control, emergency actions, and general safety. This manual supersedes all previous operating manuals for the BSR.

  10. Industrial Assessment Center (IAC) Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Gopalakrishnan, Bhaskaran [West Virginia Univ., Morgantown, WV (United States); Nimbalkar, Sachin U. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wenning, Thomas J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Thirumaran, Kiran [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    IAC Operations Manual describes organizational model and operations of the Industrial Assessment Center (IAC), Center management activities, typical process of energy assessment, and energy assessment data for specific industry sectors.

  11. Operations and Maintenance Manual, Atmospheric Contaminant Sensor, Revision B.

    Science.gov (United States)

    National Aeronautics and Space Administration, Washington, DC.

    The sensor is a mass spectrometer system which continuously monitors the atmospheric constituents of hydrogen, water vapor, nitrogen, oxygen, and carbon dioxide, and monitors the Freons on a demand sampling basis. The manual provides a system description, operational procedures, and maintenance and troubleshooting instructions. Circuit diagrams…

  12. Davis PV plant operation and maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This operation and maintenance manual contains the information necessary to run the Photovoltaics for Utility Scale Applications (PVUSA) test facility in Davis, California. References to more specific information available in drawings, data sheets, files, or vendor manuals are included. The PVUSA is a national cooperative research and demonstration program formed in 1987 to assess the potential of utility scale photovoltaic systems.

  13. PEBBLES Operation and Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Joshua J. Cogliati

    2011-02-01

    The PEBBLES manual describes the PEBBLES code. The PEBBLES code is a computer program designed to simulation the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke’s law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method.

  14. PEBBLES Operation and Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Joshua J. Cogliati

    2010-09-01

    The PEBBLES manual describes the PEBBLES code. The PEBBLES code is a computer program designed to simulation the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke’s law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method.

  15. US Fish and Wildlife Service lands biomonitoring operations manual

    Energy Technology Data Exchange (ETDEWEB)

    Rope, R.C.; Breckenridge, R.P.

    1993-08-01

    This is Volume 1 of an operations manual designed to facilitate the development of biomonitoring strategies for U.S. Fish and Wildlife Service Lands. It is one component of the U.S. Fish and Wildlife Service Lands Biomonitoring Operations Manual. The Volume contains the Introduction to the Manual, background information on monitoring, and procedures for developing a biomonitoring strategy for Service lands. The purpose of the Biomonitoring Operations Manual is to provide an approach to develop and implement biomonitoring activities to assess the status and trends of U.S. Fish and Wildlife Service trust resources. It also provides field sampline methods and documentation protocols for contaminant monitoring activities. The strategy described in the Manual has been designed as a stand alone process to characterize the presence of contaminants on lands managed by the Service. This process can be sued to develop a monitoring program for any tract of real estate with potential threats from on- or off-site contaminants. Because the process was designed to address concerns for Service lands that span the United States from Alaska to the Tropical Islands, it has a generic format that can be used in al types of ecosystems, however, significant site specific informtion is required to complete the Workbook and make the process work successfully.

  16. Acoustic Flow Monitor System - User Manual

    Science.gov (United States)

    LaHusen, Richard

    2005-01-01

    INTRODUCTION The Acoustic Flow Monitor (AFM) is a portable system that was designed by the U.S. Geological Survey Cascades Volcano Observatory to detect and monitor debris flows associated with volcanoes. It has been successfully used internationally as part of real-time warning systems in valleys threatened by such flows (Brantley, 1990; Marcial and others, 1996; Lavigne and others, 2000). The AFM system has also been proven to be an effective tool for monitoring some non-volcanic debris flows. This manual is intended to serve as a basic guide for the installation, testing, and maintenance of AFM systems. An overview of how the system works, as well as instructions for installation and guidelines for testing, is included. Interpretation of data is not covered in this manual; rather, the user should refer to the references provided for published examples of AFM data.

  17. Manually operated elastomer heat pump

    Science.gov (United States)

    Hutchinson, W. D.

    1970-01-01

    Device consisting of a rotating mechanism, a frame with multiple wide bands of rubber, and a fluid bath, demonstrates the feasibility of a human operated device capable of cooling or producing heat. This invention utilizes the basic thermodynamic properties of natural rubber.

  18. Video animation system operators manual

    Energy Technology Data Exchange (ETDEWEB)

    Mareda, J.F.

    1992-09-01

    This document describes the components necessary to put together a video animation system. It is primarily intended for use at Sandia National Laboratories as it describes the components used in systems at Sandia. The main document covers the operation of the equipment in some detail and is intended for either the system maintainer or an advanced user. There is an appendix for each of the three systems in use by the Engineering Sciences Directorate which contain instructions for the general user.

  19. 33 CFR 127.1309 - Operations Manual and Emergency Manual: Use.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operations Manual and Emergency Manual: Use. 127.1309 Section 127.1309 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF....1309 Operations Manual and Emergency Manual: Use. Each operator of a waterfront facility handling...

  20. Janus neodymium glass laser operations manual

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, J.M.; Holmes, N.C.; Trainor, R.J.

    1978-09-29

    A manual, prepared to guide personnel in operating and maintaining the Janus glass laser system, is presented. System components are described in detail. Step-by-step procedures are presented for firing the laser and for performing routine maintenance and calibration procedures.

  1. Operation and Maintenance Manual for the Central Facilities Area Sewage Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Norm Stanley

    2011-02-01

    This Operation and Maintenance Manual lists operator and management responsibilities, permit standards, general operating procedures, maintenance requirements and monitoring methods for the Sewage Treatment Plant at the Central Facilities Area at the Idaho National Laboratory. The manual is required by the Municipal Wastewater Reuse Permit (LA-000141-03) the sewage treatment plant.

  2. 33 CFR 154.750 - Compliance with operations manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Compliance with operations manual... Compliance with operations manual. The facility operator shall require facility personnel to use the procedures in the operations manual prescribed by § 154.300 for operations under this part....

  3. The Purpose of an Operations Manual.

    Science.gov (United States)

    Stevens, Drew

    2015-01-01

    In the healthcare practice, proper systems are needed. As employees are hired, it is necessary to obtain and provide applications, resumes, job descriptions, daily office procedures, operating hours, and other such information. A proper workflow must be implemented to ensure that all work points to the purpose of patient retention and acquisition. One of the factors to ensure that all employees work from the same perspective is having a written formula of policies and procedures. Often called an operations manual, the document provides the framework upon which employees all base their approach to greeting patients, scheduling them, and billing them, and often to obtain referrals. This article reviews the components of a strong operations manual.

  4. Dounreay Shuffler diagnostic software operations manual

    Energy Technology Data Exchange (ETDEWEB)

    Eccleston, G.W.; Stuewe, B.; Klosterbuer, S.; Van Lyssel, T.

    1985-07-01

    This operations manual describes the test software for the Dounreay Shuffler. The Shuffler is an assay system, controlled by a Commodore PET computer, that measures the plutonium content in leached hulls at the fuel reprocessing plant in Dounreay, Scotland. The Shuffler contains a /sup 252/Cf neutron source that is moved between storage and irradiation locations to obtain measurement data. A stepping motor control (SMC) module operates the Shuffler and accepts commands from the PET to move the source. This manual briefly describes the Shuffler and provides details on running and using the diagnostic software program. The communications protocol for message transmittal between the PET and SMC is defined and a detailed example of message sending is presented in an appendix.

  5. 14 CFR 91.1023 - Program operating manual requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Program operating manual requirements. 91... Ownership Operations Program Management § 91.1023 Program operating manual requirements. (a) Each program manager must prepare and keep current a program operating manual setting forth procedures and...

  6. 33 CFR 154.300 - Operations manual: General.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operations manual: General. 154... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Operations Manual § 154.300 Operations manual: General. (a) The facility operator of each facility to which this part applies...

  7. 33 CFR 150.25 - Amending the operations manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Amending the operations manual... (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: OPERATIONS General § 150.25 Amending the operations manual. (a) Whenever the cognizant Captain of the Port (COTP) finds that the operations manual does not meet...

  8. 46 CFR 130.480 - Test procedure and operations manual.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Test procedure and operations manual. 130.480 Section....480 Test procedure and operations manual. (a) A procedure for tests to be conducted on automated... detailed operations manual that describes the operation and indicates the location of each system...

  9. Transportable Xenon Laboratory (TXL-1) Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Robert C.; Stewart, Timothy L.; Willett, Jesse A.; Woods, Vincent T.

    2011-03-07

    The Transportable Xenon Laboratory Operations Manual is a guide to set up and shut down TXL, a fully contained laboratory made up of instruments to identify and measure concentrations of the radioactive isotopes of xenon by taking air samples and analyzing them. The TXL is housed in a standard-sized shipping container. TXL can be shipped to and function in any country in the world.

  10. Manually operated piston-driven shock tube

    OpenAIRE

    Reddy, KPJ; Sharath, N

    2013-01-01

    A simple hand-operated shock tube capable of producing Mach 2 shock waves is described. Performance of this miniature shock tube using compressed high pressure air created by a manually operated piston in the driver section of the shock tube as driver gas with air at 1 atm pressure as the test gas in the driven tube is presented. The performance of the shock tube is found to match well with the theoretically estimated values using normal shock relations. Applications of this shock tube named ...

  11. 33 CFR 154.320 - Operations manual: Amendment.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Operations manual: Amendment. 154... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Operations Manual § 154.320 Operations manual: Amendment. (a) Using the following procedures, the COTP may require the facility...

  12. 7 CFR 300.2 - Dry Kiln Operator's Manual.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Dry Kiln Operator's Manual. 300.2 Section 300.2... SERVICE, DEPARTMENT OF AGRICULTURE INCORPORATION BY REFERENCE § 300.2 Dry Kiln Operator's Manual. (a) The Dry Kiln Operator's Manual, which was published in August 1991 as Agriculture Handbook No. 188 by...

  13. Hanford Environmental Information System (HEIS) Operator`s Manual. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Schreck, R.I.

    1991-10-01

    The Hanford Environmental Information System (HEIS) is a consolidated set of automated resources that effectively manage the data gathered during environmental monitoring and restoration of the Hanford Site. The HEIS includes an integrated database that provides consistent and current data to all users and promotes sharing of data by the entire user community. This manual describes the facilities available to the operational user who is responsible for data entry, processing, scheduling, reporting, and quality assurance. A companion manual, the HEIS User`s Manual, describes the facilities available-to the scientist, engineer, or manager who uses the system for environmental monitoring, assessment, and restoration planning; and to the regulator who is responsible for reviewing Hanford Site operations against regulatory requirements and guidelines.

  14. 49 CFR 236.919 - Operations and Maintenance Manual.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operations and Maintenance Manual. 236.919 Section... for Processor-Based Signal and Train Control Systems § 236.919 Operations and Maintenance Manual. (a... Maintenance Manual, readily available to persons required to perform such tasks and for inspection by FRA...

  15. The FLP microsatellite platform flight operations manual

    CERN Document Server

    2016-01-01

    This book represents the Flight Operations Manual for a reusable microsatellite platform – the “Future Low-cost Platform” (FLP), developed at the University of Stuttgart, Germany. It provides a basic insight on the onboard software functions, the core data handling system and on the power, communications, attitude control and thermal subsystem of the platform. Onboard failure detection, isolation and recovery functions are treated in detail. The platform is suited for satellites in the 50-150 kg class and is baseline of the microsatellite “Flying Laptop” from the University. The book covers the essential information for ground operators to controls an FLP-based satellite applying international command and control standards (CCSDS and ECSS PUS). Furthermore it provides an overview on the Flight Control Center in Stuttgart and on the link to the German Space Agency DLR Ground Station which is used for early mission phases. Flight procedure and mission planning chapters complement the book. .

  16. Evaluation of three manually operated weeding devices.

    Science.gov (United States)

    Tewari, V K; Datta, R K; Murthy, A S

    1991-04-01

    Performance of three manually operated weeders was evaluated from ergonomics and mechanical considerations. Three operators were selected for laboratory and field trials; they represented the 5th, 50th and 95th percentiles of the operator population. Laboratory tests were conducted in a psychometric chamber to study physiological response under varying load and environmental conditions. From the data, relationships between energy expenditure rate and oxygen consumption rate vs heart rate were established. Field tests were carried out with the three weeders in a farm with Arhar crop (Cajannus Cajan L.) during August-September, when the average ambient temperature and relative humidity were 36 degrees C and 82% respectively. The results of this investigation indicated that weeding with the indigenous tools of a 'khurpi' and a spade and with the improved tool (3-tine hoe) could be rated as 'moderately heavy' work. However, a 'khurpi' demanded less energy expenditure than a 3-tine hoe followed by a spade. The squatting posture with a 'khurpi' appeared to be more comfortable than the standing posture with about 145 degrees erect position for the 3-tine hoe, followed by the standing posture with about 108 degrees erect position with the spade. For consideration of higher output, the order was spade, 3-tine hoe and 'khurpi', For weeding efficiency the trend was, however, just the reverse.

  17. DATA MONITORING AND ANALYSIS PROGRAM MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    Gravois, Melanie

    2007-07-06

    This procedure provides guidelines and techniques for analyzing and trending data using statistical methods for Lawrence Berkeley National Laboratory (LBNL). This procedure outlines the steps used in data analysis and trending. It includes guidelines for performing data analysis and for monitoring (or controlling) processes using performance indicators. This procedure is used when trending and analyzing item characteristics and reliability, process implementation, and other quality-related information to identify items, services, activities, and processes needing improvement, in accordance with 10 CFR Part 830, Subpart A, U.S. Department of Energy (DOE) Order 414.1C, and University of California (UC) Assurance Plan for LBNL. Trend codes, outlined in Attachment 4, are assigned to issues at the time of initiation and entry into the Corrective Action Tracking System (CATS) database in accordance with LBNL/PUB-5519 (1), Issues Management Program Manual. Throughout this procedure, the term performance is used to encompass all aspects of performance including quality, timeliness, efficiency, effectiveness, and reliability. Data analysis tools are appropriate whenever quantitative information describing the performance of an item, service, or process can be obtained.

  18. DATA MONITORING AND ANALYSIS PROGRAM MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    Gravois, Melanie

    2007-07-06

    This procedure provides guidelines and techniques for analyzing and trending data using statistical methods for Lawrence Berkeley National Laboratory (LBNL). This procedure outlines the steps used in data analysis and trending. It includes guidelines for performing data analysis and for monitoring (or controlling) processes using performance indicators. This procedure is used when trending and analyzing item characteristics and reliability, process implementation, and other quality-related information to identify items, services, activities, and processes needing improvement, in accordance with 10 CFR Part 830, Subpart A, U.S. Department of Energy (DOE) Order 414.1C, and University of California (UC) Assurance Plan for LBNL. Trend codes, outlined in Attachment 4, are assigned to issues at the time of initiation and entry into the Corrective Action Tracking System (CATS) database in accordance with LBNL/PUB-5519 (1), Issues Management Program Manual. Throughout this procedure, the term performance is used to encompass all aspects of performance including quality, timeliness, efficiency, effectiveness, and reliability. Data analysis tools are appropriate whenever quantitative information describing the performance of an item, service, or process can be obtained.

  19. 49 CFR 236.1039 - Operations and Maintenance Manual.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operations and Maintenance Manual. 236.1039... Train Control Systems § 236.1039 Operations and Maintenance Manual. (a) The railroad shall catalog and..., modification, inspection, and testing of the PTC system and have them in one Operations and Maintenance...

  20. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  1. Guidance Manual: Asbestos Operations & Maintenance Work Practices. Second Edition.

    Science.gov (United States)

    National Inst. of Building Sciences, Washington, DC.

    This technical manual provides detailed guidance to building owners, asbestos program managers, and operations and maintenance (O&M) workers for managing asbestos-containing materials (ACM) in buildings. The manual addresses four different types of ACM found in buildings and three different levels of precaution which may be warranted by…

  2. Remote manual operator for space station intermodule ventilation valve

    Science.gov (United States)

    Guyaux, James R.

    1996-01-01

    The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

  3. Introducing a new monitoring manual for home fortification and strengthening capacity to monitor nutrition interventions.

    Science.gov (United States)

    Jefferds, Maria Elena D; Flores-Ayala, Rafael

    2015-12-01

    Lack of monitoring capacity is a key barrier for nutrition interventions and limits programme management, decision making and programme effectiveness in many low-income and middle-income countries. A 2011 global assessment reported lack of monitoring capacity was the top barrier for home fortification interventions, such as micronutrient powders or lipid-based nutrient supplements. A Manual for Developing and Implementing Monitoring Systems for Home Fortification Interventions was recently disseminated. It is comprehensive and describes monitoring concepts and frameworks and includes monitoring tools and worksheets. The monitoring manual describes the steps of developing and implementing a monitoring system for home fortification interventions, including identifying and engaging stakeholders; developing a programme description including logic model and logical framework; refining the purpose of the monitoring system, identifying users and their monitoring needs; describing the design of the monitoring system; developing indicators; describing the core components of a comprehensive monitoring plan; and considering factors related to stage of programme development, sustainability and scale up. A fictional home fortification example is used throughout the monitoring manual to illustrate these steps. The monitoring manual is a useful tool to support the development and implementation of home fortification intervention monitoring systems. In the context of systematic capacity gaps to design, implement and monitor nutrition interventions in many low-income and middle-income countries, the dissemination of new tools, such as monitoring manuals may have limited impact without additional attention to strengthening other individual, organisational and systems levels capacities.

  4. Operating manual for the Health Physics Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1985-11-01

    This manual is intended to serve as a guide in the operation and maintenance of the Health Physics Researh Reactor (HPRR) of the Health Physics Dosimetry Applications Research (DOSAR) Facility. It includes descriptions of the HPRR and of associated equipment such as the reactor positioning devises and the derrick. Procedures for routine operation of the HPRR are given in detail, and checklists for the various steps are provided where applicable. Emergency procedures are similarly covered, and maintenance schedules are outlined. Also, a bibliography of references giving more detailed information on the DOSAR Facility is included. Changes to this manual will be approved by at least two of the following senior staff members: (1) the Operations Division Director, (2) the Reactor Operations Department Head, (3) the Supervisor of Reactor Operations TSF-HPRR Areas. The master copy and the copy of the manual issued to the HPRR Operations Supervisor will always reflect the latest revision. 22 figs.

  5. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  6. Spent nuclear fuel project cold vacuum drying facility operations manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1999-05-12

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998) and, the HNF-SD-SNF-DRD-002, 1997, Cold Vacuum Drying Facility Design Requirements, Rev. 3a. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence, and has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  7. 33 CFR 149.120 - What are the requirements for manually operated shutoff valves?

    Science.gov (United States)

    2010-07-01

    ... manually operated shutoff valves? 149.120 Section 149.120 Navigation and Navigable Waters COAST GUARD... EQUIPMENT Pollution Prevention Equipment § 149.120 What are the requirements for manually operated shutoff... have a manual shutoff valve....

  8. Nuclear Materials Identification System Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, L.G.

    2001-04-10

    This report describes the operation and setup of the Nuclear Materials Identification System (NMIS) with a {sup 252}Cf neutron source at the Oak Ridge Y-12 Plant. The components of the system are described with a description of the setup of the system along with an overview of the NMIS measurements for scanning, calibration, and confirmation of inventory items.

  9. RTOD-photo operations and procedures manual

    Energy Technology Data Exchange (ETDEWEB)

    1966-03-15

    This document presents a survey of the EG&G NRDS photographic operation in four major sections and includes the work scope, procedures, some technical backgrounding and operational information. Two sections, Instrumentation and Photo Systems, include the areas of direct responsibilities while a section on Film Handling and Coordination and a section covering special information, pertinent to the project, are included to adequately complete this survey. The photographic group is housed in two trailers within the control point area at NRDS and from these trailers provides photographic support at a number of locations. Four camera bunkers, three camera towers, a kinescope system, a microfilm system and remote camera controls comprise the facilities that the group maintains and operates outside these trailers. The work load includes major items such as: motion picture coverage of the nuclear rocket engine tests, data record microfilming, kinescope recording, and documentary coverage of the company related operational responsibilities. In addition, a number of minor photographic services are extended, when required. The nature of the work, because of its importance within the research and development efforts at NRDS, requires optimum quality and efficiency throughout. The many procedures outlined here have been designed to satisfy these requirements.

  10. The 14th Annual Conference on Manual Control. [digital simulation of human operator dynamics

    Science.gov (United States)

    1978-01-01

    Human operator dynamics during actual manual control or while monitoring the automatic control systems involved in air-to-air tracking, automobile driving, the operator of undersea vehicles, and remote handling are examined. Optimal control models and the use of mathematical theory in representing man behavior in complex man machine system tasks are discussed with emphasis on eye/head tracking and scanning; perception and attention allocation; decision making; and motion simulation and effects.

  11. Manual of Operations for the S-50 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Overman R.T.

    1945-06-01

    It is recognized that the S-50 plant operations are far from standardized and therefore any manual will require continual revision to keep it up to date. Even during the period of writing this first edition, many changes occurred and were incorporated in the manual. Such revisions could delay indefinitely the issuance of the manual and it was felt that in its present form it could be useful in the training of new plant personnel. The specific purpose of the process employed by the Ferclave Corporation in the plant at Oak Ridge, Tennessee, is one of secret information and cannot be released here. It can be stated, however, that the plant operation involves the processing of a chemical substance. This substance is not identified in the plant or in the process but is referred to only as 'material'. Its code designation is C-616. The process in general involves the separation of the raw material into constituents with more desirable properties. It is not necessary to know the name of the material nor the exact nature of the process in order to carry out the operations so this information will not be given in this Manual. The problem involved is to transport the material from the containers in which it is received by the plant into equipment set-up in the plant for carrying out the operation, to remove the various products from the process equipment and to do other auxiliary operations.

  12. Special Operations Forces Reference Manual. Fourth Edition

    Science.gov (United States)

    2015-06-01

    operational leverage by gathering critical information, undermining a potential adversary’s will or capacity to wage war, and enhancing the...Wingspan 132 ft., 7 in. (40.4m) Speed 300 mph (480 kph) Ceiling 33,000 ft. (10,000m) Load 75 troops or 50 paratroopers Max Takeoff Weight 155,000 pounds...130J Commando II Length 97 ft., 9 in (29.3m) Height 38 ft., 10 in. (11.9m) Wingspan 132 ft., 7 in. (40.4m) Speed 362 KTAS Ceiling 28,000 ft. Load 75

  13. Boiler Control Systems Theory of Operation Manual.

    Science.gov (United States)

    1983-02-01

    9 lfeduce!s routine mtainltenance N through use of bitilt-in air 4up- *,1 ilternd, ltain eisa e Simplifie.. stockintg of -.pare - parto -illre uuanyv...operation pushbuttons and two-position transfer switch. The vertical meter is a I.5v voltmeter scaled 0-ICO representing percent of the nput M vanal-le. The...by the ratio dial seting. Ie 002 Pr aie Set Satieson, curren output. Vertices ale ndiceerds*o ea tof the Storin pae atF iei signel. 1 T1wred i 22A

  14. Effluent-Monitoring Procedures: Basic Laboratory Skills. Student Reference Manual.

    Science.gov (United States)

    Engel, William T.; And Others

    This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Student Reference Manual provides a review of basic mathematics as it applies to the chemical laboratory. The…

  15. Visual tools for human guidance in manual operations

    Science.gov (United States)

    Harding, Kevin; Abramovich, Gil

    2012-06-01

    Many operations that are done manually, such as assembly operations, can be difficult to instruct to someone working in an unstructured environment that is not already familiar with the operation. The typical approach is to take pictures of the system and attempt to provide instructions using the pictures with some annotations. We have explored a variety of visual aids that might be used to provide a more real-time feedback to guide such manual operations. These methods include indirect feedback tools, such as signals or graphs to be interpreted, as well as direct methods that provide a simulated or real view of the operation as the user works. This paper will explore some of the pros and cons of these methods, and present some very preliminary results that suggest future directions for this work.

  16. Optimalisation of the process for manually operated jacket steam sterilisers

    NARCIS (Netherlands)

    Muis B; Bruijn ACP de; Drongelen AW van; Huys JFFM; LGM

    2001-01-01

    The aim of the research was to find an optimal process for a manually operated jacketed steam steriliser, which is mainly used in developing countries. The experiments were focussed on the steam penetration into a textile test pack and the drying procedure. The performance of the various test cycles

  17. Prophylactic manual rotation for fetal malposition to reduce operative delivery.

    Science.gov (United States)

    Phipps, Hala; de Vries, Bradley; Hyett, Jon; Osborn, David A

    2014-12-22

    Manual rotation is commonly performed to increase the chances of normal vaginal delivery and is perceived to be safe. Manual rotation has the potential to prevent operative delivery and caesarean section, and reduce obstetric and neonatal complications. To assess the effect of prophylactic manual rotation for women with malposition in labour on mode of delivery, and maternal and neonatal outcomes. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 October 2014), the Australian and New Zealand Clinical Trials Registry (ANZCTR), ClinicalTrials.gov, Current Controlled Trials and the WHO International Clinical Trials Registry Platform (ICTRP) (all searched 23 February 2014), previous reviews and, references of retrieved studies. Randomised, quasi-randomised or cluster-randomised clinical trials comparing prophylactic manual rotation in labour for fetal malposition versus expectant management, augmentation of labour or operative delivery. We defined prophylactic manual rotation as rotation performed without immediate assisted delivery. Two review authors independently assessed study eligibility and quality, and extracted data. We included only one small pilot study (involving 30 women). The study, which we considered to be at low risk of bias, was conducted in a tertiary referral hospital in Australia, and involved women with cephalic, singleton pregnancies. The primary outcome was operative delivery (instrumental delivery or caesarean section).In the manual rotation group, 13/15 women went on to have an instrumental delivery or caesarean section, whereas in the control group, 12/15 women had an operative delivery. The estimated risk ratio was 1.08 (95% confidence interval 0.79 to 1.49). There were no maternal or fetal mortalities in either groupThere were no clear differences for any of the secondary maternal or neonatal outcomes reported (e.g. perineal trauma, analgesia use duration of labour).In terms of adverse events, there were no

  18. The energy management manual for arena and rink operators

    Energy Technology Data Exchange (ETDEWEB)

    Raymer, M. [Saskatchewan Parks and Recreation Assoc., Regina, SK (Canada); White, T. [Office of Energy Conservation, Regina, SK (Canada); Kozoriz, D.F. [SaskPower, Regina, SK (Canada); Norman, D. [SaskPower, Saskatoon, SK (Canada)

    2006-08-15

    In an era when energy costs often rise faster than the community tax base, energy conservation plays a key role in ensuring that skating arenas are able to continue operating. This manual on energy management for arena and rink operators includes current technologies and practices that reduce operating costs. It is meant to help in the training and education of all facility operators. Since fossil fuels are the main source of electrical generation in Saskatchewan, reducing energy consumption directly reduces greenhouse gas emissions to the environment. This manual included a brief introduction to energy calculations for operators of rinks and arenas. The calculations can be performed for the heat loss that occurs in winter and the amount of heat input needed to maintain temperatures. It was recommended that the more difficult calculation of estimating the amount of cooling required for ice making should be done by qualified consultants. The 10 sections of the manual addressed the issues of: (1) electrical and natural gas rates, (2) meters and electrical inventory, (3) making a financial analysis, (4) the building envelope, (5) heating and ventilation, (6) refrigeration, (7) lighting, (8) heating effects of electrical equipment, (9) operation and maintenance, and, (10) project planning. The manual also presented methods to improve the power factor by adding relatively inexpensive components, such as capacitors, to lower electricity bills by as much as 20 per cent. A review of geo-exchange systems for rinks and arenas was included along with heat recovery from refrigeration systems and financial assistance for commercial, institutional and municipal buildings. refs., tabs., figs.

  19. 77 FR 43606 - Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR)

    Science.gov (United States)

    2012-07-25

    ... Operations Manual (9327.2-PR) AGENCY: Federal Emergency Management Agency, DHS. ACTION: Notice of... Assessment for Individual Assistance Operations Manual (9327.2-PR). The Federal Emergency Management Agency..., 2011. DATES: This manual is effective July 18, 2012. ADDRESSES: This final manual is available...

  20. Remote monitoring of pipeline operations

    Energy Technology Data Exchange (ETDEWEB)

    Bost, R.C. [ERM-Southwest, Inc., Houston, TX (United States); White, D. [Glenrose Systems, Austin, TX (United States)

    1995-12-31

    The demands for monitoring of pipeline operations have recently increased greatly due to new regulatory requirements. Most companies rely upon conventional System Control and Data Acquisition (SCADA) system architecture to meet their needs. Current systems are often plagued by limited data conversion and processing capacity at the workstations. A state-of-the-art Data Acquisition Node (DAN) that relieves the workstation of much of its workload is described in this paper. Use of this DAN may eliminate the need for installing completely new systems. It facilitates marrying foreign devices to existing operation monitoring systems to satisfy new regulatory requirements. The DAN allows a system to utilize commercial communications satellites or other communication networks and real-time, object oriented programming and different devices and data requirements without the necessity of custom software development.

  1. Time warp operating system version 2.7 internals manual

    Science.gov (United States)

    1992-01-01

    The Time Warp Operating System (TWOS) is an implementation of the Time Warp synchronization method proposed by David Jefferson. In addition, it serves as an actual platform for running discrete event simulations. The code comprising TWOS can be divided into several different sections. TWOS typically relies on an existing operating system to furnish some very basic services. This existing operating system is referred to as the Base OS. The existing operating system varies depending on the hardware TWOS is running on. It is Unix on the Sun workstations, Chrysalis or Mach on the Butterfly, and Mercury on the Mark 3 Hypercube. The base OS could be an entirely new operating system, written to meet the special needs of TWOS, but, to this point, existing systems have been used instead. The base OS's used for TWOS on various platforms are not discussed in detail in this manual, as they are well covered in their own manuals. Appendix G discusses the interface between one such OS, Mach, and TWOS.

  2. ADST Operation Manual for the Management Command and Control. Volume 2. SIMNET/MASSCOMP Host MCC

    Science.gov (United States)

    1993-03-31

    Simulator: 9A A Company A Helicopter Type @ Attack 0 Defense 0 Scout 0 Offense Dumper No. Li)I Obseruer Location Azimuth (Mils) Fuel Load 12444 (Lbs...new mission or monitor on-going missions with the use of messages and requests for information. Before a mission can be completed, several steps must...mission and to return to Figure 9-1. Click on the No changes button to cancel the changes. Page 164 SIMNET Operations Manual March 31, 1993 9.4 Monitoring

  3. Controlatron Neutron Tube Test Suite Software Manual - Operation Manual (V2.2)

    CERN Document Server

    Noel, W P; Hertrich, R J; Martinez, M L; Wallace, D L

    2002-01-01

    The Controlatron Software Suite is a custom built application to perform automated testing of Controlatron neutron tubes. The software package was designed to allowing users to design tests and to run a series of test suites on a tube. The data is output to ASCII files of a pre-defined format for data analysis and viewing with the Controlatron Data Viewer Application. This manual discusses the operation of the Controlatron Test Suite Software and a brief discussion of state machine theory, as state machine is the functional basis of the software.

  4. 76 FR 63628 - Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR)

    Science.gov (United States)

    2011-10-13

    ... [Docket ID FEMA-2011-0022] Preliminary Damage Assessment for Individual Assistance Operations Manual (9327... Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR). DATES: Comments must be... . Follow the instructions for submitting comments. Please note that this proposed manual is not...

  5. Air pollution prevention manual on emission monitoring. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-08-15

    The Manual on Emission Monitoring covers the need for information about the national practice in the field of emission control at plants, requiring official approval. The legal bases for discontinuous and continuous measurements for emission control at plants, requiring official approval, are treated. Thereby also the European environmental legislation is considered. The publication procedure for testing institutes, which execute such measurements, is described. The execution of discontinuous emission measurements (course of the measurement and measurement requests) and for continuous emission measurement (suitability test, installation, maintenance, functional test and calibration of the automated measuring system) including the evaluation and documentation of the measured values is described. The procedure of remote emission monitoring is explained. The most important measuring procedures (continuous and discontinuous) are reported. The guide also includes an up-to-date list of tested and appropriate measurement devices. Such tested measuring devices are described by their manufacturers. Indications are given as to how the devices function together with their technical data (e. g. parameters from the suitability test). (orig.)

  6. Operating instructions included : a review of social investment fund operations manuals

    OpenAIRE

    Juliana Weissman

    2001-01-01

    Social investment funds are being used in a growing number of countries, to alleviate the impact of political, social, and economic crises, cushion the impact of adjustment programs, generate employment, and, finance small-scale investments in poor communities. The social funds operations manuals promote transparency with respect to social fund organization, and the administrative, financial, and technical arrangements used by the fund to execute its program. This study reviews the operations...

  7. ORIS: the Oak Ridge Imaging System operation's manual

    Energy Technology Data Exchange (ETDEWEB)

    Bell, P. R.; Dillon, R. S.

    1977-12-01

    The Oak Ridge Imaging System (ORIS) programs are briefly described. This volume is intended as an operators manual, but it includes program abstracts and instructions for assembling the modules and adding new ones. The instructions are specifically for the RK8E version, but they apply with minor changes to versions for other OS/8 devices. The system provides for access, storage, processing, and display of nuclear medicine images and for any other type of data displayable in image form. The system is not limited to square image arrays or to any specific size of data arrays below 16K elements. The complete code package for ORIS is available as MED-8/ORIS from the Biomedical Computing Technology Information Center (BCTIC), Oak Ridge National Laboratory.

  8. Configuration Design of Novel Manually Operated Dynamo Flashlights

    Science.gov (United States)

    Yan, Hong-Sen; Wang, Hsin-Te

    This paper synthesizes novel configurations of manually operated dynamo flashlights. Topology and motion characteristics of existing gear dynamos are modified and concluded. The structural sketches and corresponding graph representations for gear trains and dynamos with the defined induced magnetic circuits are defined. Through the concepts of generalization and specialization, the atlas of the structural sketches and graphs of the embedded gear dynamos is obtained subject to the defined design requirements and constraints. And, a systematic approach is proposed to synthesize the novel mechanisms of the embedded gear dynamos. As a result, the embedded three-link and four-link gear dynamos have 12 and 24 novel design configurations, respectively. One prototype of the embedded three-link and another of the embedded four-link gear dynamo are built.

  9. SENTINEL-1 RESULTS: SEA ICE OPERATIONAL MONITORING

    DEFF Research Database (Denmark)

    Toudal Pedersen, Leif; Saldo, Roberto; Fenger-Nielsen, Rasmus

    2015-01-01

    In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production.......In the present paper we demonstrate the capabilities of the Sentinel-1 SAR data for operational sea-ice and iceberg monitoring. Most of the examples are drawn from the Copernicus Marine Environmental Monitoring Service (CMEMS) production....

  10. Manual of procedures for the operation of bench-scale anaerobic digesters

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, R.R.

    1978-12-01

    The successful operation of any laboratory-scale biological system is often a difficult and frustrating experience. This is especially true when dealing with the anaerobic digestion process. Because of the stringent environmental requirements associated with anaerobic digesters, efficient operation of bench-scale units requires rigid monitoring and control. The purpose of this manual is to present the methods and procedures which are followed in bench-scale anaerobic digestion studies at Pacific Northwest Laboratory (PNL). Among the topics discussed are operating parameters, a description of the experimental system, typical digestion substrates, operational procedures, analytical techniques, and safety considerations. The document serves as a technical guide to PNL personnel assigned to a U.S. Department of Energy sponsored program evaluating the effect of powdered activated carbon on the anaerobic digestio of sewage sludge. It should be noted that the methods described in this manual do not necessarily represent the best or only means of conducting the research. They are merely procedures that have been found to be successful at PNL. It is hoped that this information may be useful to other researchers who are contemplating or pursuing bench-scale studies of their own.

  11. Operator's Manual, Boiler Room Operations and Maintenance. Supplement A, Air Pollution Training Institute Self-Instructional Course SI-466.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Training Inst.

    This Operator's Manual is a supplement to a self-instructional course prepared for the United States Environmental Protection Agency. This publication is the Boiler Room Handbook for operating and maintaining the boiler and the boiler room. As the student completes this handbook, he is putting together a manual for running his own boiler. The…

  12. Operator's manual actions in case of fire; Acciones manuales del operador en caso de incendio

    Energy Technology Data Exchange (ETDEWEB)

    Saez de Tejada Madina, P.; Perez Lobo, E. M.; Velasco Ramirez, R.; Velasco Ramirez, R.; Fernandez Ramos, P.

    2012-07-01

    Vandellos II, following the guidelines GS 01.19 of CSN and RG 1.189 rev. 2, has identified the need to consider a number of local manual actions to be performed by the staff of shift operation and need to be validated according NUREG 1852. The local manual actions include corrective and preventive actions, such as local start and shooting of bombs, checking positions ... According NUREG-1852 these actions must be validated with conditions as similar as possible to those expected, in conjunction with the operating of Vandellos II.

  13. Independent Electricity Market Operator integration management participant technical reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-11-15

    The document provides potential participants with the essential technical information to permit them to participate in the IMO-administered markets, and is not intended to be a complete technical reference manual for all issues within the realm of electricity production, distribution, or consumption. Written for the participants, it provides only that information which is relevant to the participant for interfacing with the IMO and participating in the market. Written as a generic guide, all the information contained within it may not be relevant to all the participants. The document's intent is to provide participants with a description of the various facilities and interfaces required by market participants to take part in the IMO-administered markets. The document supplements the market rules and provides installation, set-up, and configuration information for the various tools and facilities that will be required for market participation as a supplier, carrier/delivery (transmitter/distributer), generator, or consumer in the market. Aspects considered include: participant workstation specifications, dispatch workstation specification, message exchange, remote terminal unit specification, AGC operational RTU specification, real time network connection specification, telephone connection specification, revenue administration specification, funds administration specification, data catalogues, market information, power grid connection requirements, and appendices.

  14. Federal Radiological Monitoring and Assessment Center Health and Safety Manual

    Energy Technology Data Exchange (ETDEWEB)

    FRMAC Health and Safety Working Group

    2012-03-20

    This manual is a tool to provide information to all responders and emergency planners and is suggested as a starting point for all organizations that provide personnel/assets for radiological emergency response. It defines the safety requirements for the protection of all emergency responders. The intent is to comply with appropriate regulations or provide an equal level of protection when the situation makes it necessary to deviate. In the event a situation arises which is not addressed in the manual, an appropriate management-level expert will define alternate requirements based on the specifics of the emergency situation. This manual is not intended to pertain to the general public.

  15. Typing operations manual and disposal of fixed assets: directions of improvement of accounting

    Directory of Open Access Journals (Sweden)

    I.M. Vygivska

    2016-09-01

    Full Text Available The lack of studies on the structure of business operations for the operation and disposal of fixed assets leads to undeveloped organizational and methodological provisions of the relevant accounting operations. In particular, the lack of comprehensive understanding of these operations can not account for the loss of alternatives and economic benefits from the use of fixed assets in various areas of economic activity. To streamline the organizational and methodological approaches to accounting of fixed assets, and monitor the effectiveness of the use and preservation of the property of the owner of the enterprise, and according to the analysis of literary sources showing a considerable amount of controversy in the existing approach of the authors, to characterize the operations manual and the disposal of fixed assets, the article suggests typing operations, exploitation and disposal of fixed assets. The main types of these operations include: 1 operation – storage, use, maintenance, repair and improvement; 2 disposal - sale, free transfer, exchange, cancellation due to moral and physical deterioration, capital contribution, financial lease, the installation of shortage, the transfer in payment of debt, the loss resulting from emergencies.

  16. 33 CFR 157.224 - Dedicated Clean Ballast Tanks Operations Manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels Design and Equipment § 157.224 Dedicated Clean Ballast Tanks Operations Manual. Each Dedicated Clean Ballast Tanks Operations Manual...

  17. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    Science.gov (United States)

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  18. Condition Monitoring Of Operating Pipelines With Operational Modal Analysis Application

    Directory of Open Access Journals (Sweden)

    Mironov Aleksey

    2015-12-01

    Full Text Available In the petroleum, natural gas and petrochemical industries, great attention is being paid to safety, reliability and maintainability of equipment. There are a number of technologies to monitor, control, and maintain gas, oil, water, and sewer pipelines. The paper focuses on operational modal analysis (OMA application for condition monitoring of operating pipelines. Special focus is on the topicality of OMA for definition of the dynamic features of the pipeline (frequencies and mode shapes in operation. The research was conducted using two operating laboratory models imitated a part of the operating pipeline. The results of finite-element modeling, identification of pipe natural modes and its modification under the influence of virtual failure are discussed. The work considers the results of experimental research of dynamic behavior of the operating pipe models using one of OMA techniques and comparing dynamic properties with the modeled data. The study results demonstrate sensitivity of modal shape parameters to modification of operating pipeline technical state. Two strategies of pipeline repair – with continuously condition-based monitoring with proposed technology and without such monitoring, was discussed. Markov chain reliability models for each strategy were analyzed and reliability improvement factor for proposed technology of monitoring in compare with traditional one was evaluated. It is resumed about ability of operating pipeline condition monitoring by measuring dynamic deformations of the operating pipe and OMA techniques application for dynamic properties extraction.

  19. Monitored Geologic Repository Operations Monitoring and Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    E.F. Loros

    2000-06-29

    The Monitored Geologic Repository Operations Monitoring and Control System provides supervisory control, monitoring, and selected remote control of primary and secondary repository operations. Primary repository operations consist of both surface and subsurface activities relating to high-level waste receipt, preparation, and emplacement. Secondary repository operations consist of support operations for waste handling and treatment, utilities, subsurface construction, and other selected ancillary activities. Remote control of the subsurface emplacement operations, as well as, repository performance confirmation operations are the direct responsibility of the system. In addition, the system monitors parameters such as radiological data, air quality data, fire detection status, meteorological conditions, unauthorized access, and abnormal operating conditions, to ensure a safe workplace for personnel. Parameters are displayed in a real-time manner to human operators regarding surface and subsurface conditions. The system performs supervisory monitoring and control for both important to safety and non-safety systems. The system provides repository operational information, alarm capability, and human operator response messages during emergency response situations. The system also includes logic control to place equipment, systems, and utilities in a safe operational mode or complete shutdown during emergency response situations. The system initiates alarms and provides operational data to enable appropriate actions at the local level in support of emergency response, radiological protection response, evacuation, and underground rescue. The system provides data communications, data processing, managerial reports, data storage, and data analysis. This system's primary surface and subsurface operator consoles, for both supervisory and remote control activities, will be located in a Central Control Center (CCC) inside one of the surface facility buildings. The system

  20. 33 CFR 157.210 - Approved Dedicated Clean Ballast Tanks Operations Manual.

    Science.gov (United States)

    2010-07-01

    ... RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.210 Approved Dedicated Clean Ballast Tanks Operations Manual. If the manuals submitted under § 157.206... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Approved Dedicated Clean...

  1. Approach strategy and working posture in manual hand tool operation

    NARCIS (Netherlands)

    Chang, S.W.; Delleman, N.J.; Wang, M.J.J.

    2010-01-01

    The strategy for approaching a manual work position is an important reference for describing a goal-directed task. However, knowledge on this aspect of human behavior is scarce. The objectives of this study are twofold: (1) to describe and understand the strategy people tend to adopt for approaching

  2. Spent Nuclear Fuel (SNF) Cold Vacuum Drying (CVD) Facility Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1999-07-02

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-553, Spent Nuclear Fuel Project Final Safety Analysis Report Annex B--Cold Vacuum Drying Facility. The HNF-SD-SNF-DRD-002, 1999, Cold Vacuum Drying Facility Design Requirements, Rev. 4, and the CVDF Final Design Report. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence and references to the CVDF System Design Descriptions (SDDs). This manual has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  3. 49 CFR 192.605 - Procedural manual for operations, maintenance, and emergencies.

    Science.gov (United States)

    2010-10-01

    ... maintenance activities and for emergency response. For transmission lines, the manual must also include... control room management procedures required by § 192.631. (c) Abnormal operation. For transmission lines... gas distribution operators that are operating transmission lines in connection with their...

  4. 32 CFR 2004.20 - National Industrial Security Program Operating Manual (NISPOM) [201(a)].

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false National Industrial Security Program Operating... INFORMATION SECURITY OVERSIGHT OFFICE, NATIONAL ARCHIVES AND RECORDS ADMINISTRATION NATIONAL INDUSTRIAL SECURITY PROGRAM DIRECTIVE NO. 1 Operations § 2004.20 National Industrial Security Program Operating Manual...

  5. 33 CFR 127.309 - Operations Manual and Emergency Manual: Use.

    Science.gov (United States)

    2010-07-01

    ... SECURITY (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.309...

  6. Operational Monitoring of Data Production at KNMI

    Science.gov (United States)

    van de Vegte, John; Kwidama, Anecita; van Moosel, Wim; Oosterhof, Rijk; de Wit de Wit, Ronny; Klein Ikkink, Henk Jan; Som de Cerff, Wim; Verhoef, Hans; Koutek, Michal; Duin, Frank; van der Neut, Ian; verhagen, Robert; Wollerich, Rene

    2016-04-01

    Within KNMI a new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. Traditionally these applications are individually monitored by different applications or not at all; complicating root cause and impact analysis. Also, the underlying hardware and network is monitored via an isolated application. Goal of the PRISMA system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what downstream products/customers will be effected). The PRISMA system will make it possible to reduce existing monitoring applications and provides one interface for monitoring the data production. For modeling and storing the state of the production chains a graph database is used. The model is automatically updated by the applications and systems which are to be monitored. The graph models enables root cause and impact analysis. In the PRISMA web interface interaction with the graph model is accomplished via a graphical representation. The presentation will focus on aspects of: • Modeling real world computers, applications, products to a conceptual model; • Architecture of the system; • Configuration information and (real world) event handling of the to be monitored objects; • Implementation rules for root cause and impact analysis. • How PRISMA was developed (methodology, facts, results) • Presentation of the PRISMA system as it now looks and works

  7. 49 CFR 193.2507 - Monitoring operations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Monitoring operations. 193.2507 Section 193.2507 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES...

  8. Operation of International Monitoring System Network

    Science.gov (United States)

    Nikolova, Svetlana; Araujo, Fernando; Aktas, Kadircan; Malakhova, Marina; Otsuka, Riyo; Han, Dongmei; Assef, Thierry; Nava, Elisabetta; Mickevicius, Sigitas; Agrebi, Abdelouaheb

    2015-04-01

    The IMS is a globally distributed network of monitoring facilities using sensors from four technologies: seismic, hydroacoustic, infrasound and radionuclide. It is designed to detect the seismic and acoustic waves produced by nuclear test explosions and the subsequently released radioactive isotopes. Monitoring stations transmit their data to the IDC in Vienna, Austria, over a global private network known as the GCI. Since 2013, the data availability (DA) requirements for IMS stations account for quality of the data, meaning that in calculation of data availability data should be exclude if: - there is no input from sensor (SHI technology); - the signal consists of constant values (SHI technology); Even more strict are requirements for the DA of the radionuclide (particulate and noble gas) stations - received data have to be analyzed, reviewed and categorized by IDC analysts. In order to satisfy the strict data and network availability requirements of the IMS Network, the operation of the facilities and the GCI are managed by IDC Operations. Operations has following main functions: - to ensure proper operation and functioning of the stations; - to ensure proper operation and functioning of the GCI; - to ensure efficient management of the stations in IDC; - to provide network oversight and incident management. At the core of the IMS Network operations are a series of tools for: monitoring the stations' state of health and data quality, troubleshooting incidents, communicating with internal and external stakeholders, and reporting. The new requirements for data availability increased the importance of the raw data quality monitoring. This task is addressed by development of additional tools for easy and fast identifying problems in data acquisition, regular activities to check compliance of the station parameters with acquired data by scheduled calibration of the seismic network, review of the samples by certified radionuclide laboratories. The DA for the networks of

  9. Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    2000-02-03

    This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of the Processing Systems (Garvin 1998) and, the HNF-SD-SNF-DRD-002, 1997, Cold Vacuum Drying Facility Design Requirements, Rev. 3a. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence, and has been developed for the spent nuclear fuel project (SNFP) Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  10. Operation of Wastewater Treatment Plants, Manual of Practice No. 11.

    Science.gov (United States)

    Albertson, Orrie E.; And Others

    This book is intended to be a reference or textbook on the operation of wastewater treatment plants. The book contains thirty-one chapters and three appendices and includes the description, requirements, and latest techniques of conventional unit process operation, as well as the symptoms and corrective measures regarding process problems. Process…

  11. In Vivo Monitoring Program Manual, PNL-MA-574

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, Timothy P.

    2010-07-01

    An overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance. Overall responsibility for the management of the IVMP rests with the Program Manager (PM). The PM is responsible for providing the required in vivo counting services for Hanford Site contractor employees in accordance with Department of Energy (DOE) requirements and the specific statements of work.

  12. Manual for SFR R and D and Technology Monitoring System Administrator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Uk; Lee, Yong Bum; Won, Byung Chool; Kim, Young In; Hahn, Do Hee

    2008-05-15

    This report is a administrator manual on R and D and technology monitoring system that is applicable for managing the generation IV sodium-cooled fast reactor development. First of all, enterprise project management solution is introduced and then enterprise resources and data creation method are described. Also it made a description of project web assess design, data management method etc.

  13. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  14. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  15. 3D facial landmarks: Inter-operator variability of manual annotation

    DEFF Research Database (Denmark)

    Fagertun, Jens; Harder, Stine; Rosengren, Anders;

    2014-01-01

    was randomly chosen. Six operators twice manually annotated 73 anatomical and pseudo-landmarks, using a three-step scheme producing a dense point correspondence map. We analyzed both the intra- and inter-operator variability, using mixed-model ANOVA. We then compared four sparse sets of landmarks in order...

  16. Shuttle operations simulation model programmers'/users' manual

    Science.gov (United States)

    Porter, D. G.

    1972-01-01

    The prospective user of the shuttle operations simulation (SOS) model is given sufficient information to enable him to perform simulation studies of the space shuttle launch-to-launch operations cycle. The procedures used for modifying the SOS model to meet user requirements are described. The various control card sequences required to execute the SOS model are given. The report is written for users with varying computer simulation experience. A description of the components of the SOS model is included that presents both an explanation of the logic involved in the simulation of the shuttle operations cycle and a description of the routines used to support the actual simulation.

  17. Operation Manual of the high voltage generator of the Pelletron electron accelerator; Manual de operacion del generador de alto voltaje del acelerador de electrones Pelletron

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, V.; Lopez V, H.; Alba P, U

    1988-04-15

    The first version of a manual to operate the generator of high voltage generator of the Pelletron electron accelerator built in the ININ is presented. Since this generator has several components and/or elements, the one manual present has the purpose that the armed one or maintenance of anyone on its parts, is carried out in an orderly and efficient way. (Author)

  18. Non-RF Chain of Custody Item Monitor (CoCIM) User Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Brotz, Jay Kristoffer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wade, James Rokwel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schwartz, Steven Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-06-01

    This User Manual contains a description of the wired and infrared (IR) variants of the Chain of Custody Item Monitor (CoCIM), the Coordinator for reading stored messages, and the inspector Message Viewer user interface (UI) software, as well as instructions for use. This manual does not include descriptions or use instructions for the radio frequency (RF) variant of the CoCIM. The intended audience is planners and participants in treaty verification exercises where chain of custody (CoC) elements are required.

  19. Compressed Aeronautical Chart Processing Operator’s Manual

    Science.gov (United States)

    2007-11-02

    the processing thread A4A denotes a CAC ODI build for an (A) aeronautical chart at the (4) operational navigation chart (ONC) (1:1M) scale with...builds when both charts are at the same scale. For example, the processing thread A4A denotes a CAC ODI build for an (A) aeronautical chart at the (4

  20. Operations manual for the Beneficial Uses Shipping System cask. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Bronowski, D.R.; Yoshimura, H.R.

    1993-04-01

    This document is the Operations Manual for the Beneficial Uses Shipping System (BUSS) cask. These operating instructions address requirements; for loading, shipping, and unloading, supplementing general operational information found in the BUSS Safety Analysis Report for Packaging (SARP), SAND 83-0698. Use of the BUSS cask is authorized by Department of Energy (DOE) and Nuclear Regulatory Commission (NRC) for the shipment of special form cesium chloride or strontium flouride capsules.

  1. Architectural study of the design and operation of advanced force feedback manual controllers

    Science.gov (United States)

    Tesar, Delbert; Kim, Whee-Kuk

    1990-01-01

    A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof

  2. Development of a Water Treatment Plant Operation Manual Using an Algorithmic Approach.

    Science.gov (United States)

    Counts, Cary A.

    This document describes the steps to be followed in the development of a prescription manual for training of water treatment plant operators. Suggestions on how to prepare both flow and narrative prescriptions are provided for a variety of water treatment systems, including: raw water, flocculation, rapid sand filter, caustic soda feed, alum feed,…

  3. 33 CFR 157.212 - Dedicated Clean Ballast Tanks Operations Manual: Not approved.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.212 Dedicated Clean Ballast Tanks Operations Manual: Not approved. If the Dedicated Clean...

  4. 33 CFR 157.208 - Dedicated Clean Ballast Tanks Operations Manual for foreign tank vessels: Submission.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.208 Dedicated Clean Ballast Tanks Operations Manual for foreign tank...

  5. Manual of Operation for Administrative Functions, Wisconsin State University - Whitewater, 1971.

    Science.gov (United States)

    Wisconsin State Univ., Whitewater.

    This Manual of Operation for the Administrative Functions at Wisconsin State University, Whitewater was developed to more clearly identify the administrative organization at WSU and to delineate the functions of the principal administrative officers. Part I presents state statutes and procedures outlining the authority for governance at State…

  6. Development of a Water Treatment Plant Operation Manual Using an Algorithmic Approach.

    Science.gov (United States)

    Counts, Cary A.

    This document describes the steps to be followed in the development of a prescription manual for training of water treatment plant operators. Suggestions on how to prepare both flow and narrative prescriptions are provided for a variety of water treatment systems, including: raw water, flocculation, rapid sand filter, caustic soda feed, alum feed,…

  7. The KAERI 10 MeV Electron Linac - Description and Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Cheol; Park, Seong Hee; Jung, Young Uk; Han, Young Hwan; Kang, Hee Young

    2005-06-15

    The objective of this technical report is to guide the right operation and maintenance of the KAERI electron linac system. The KAERI electron linac system consists of 2 MeV injector based on 176 MHz Normal conducting RF (Radio Frequency)cavity and 10 MeV main accelerator based on 352 MHz Superconducting RF cavity, electron beamlines (injection and extraction). Since a electron accelerator generates hazard radiation, this system is located at the shielded room in basement and we can operate the system using the remote control system. It includes the description and the operational manual as well as the detailed technical direction for trouble shooting.

  8. Westinghouse Hanford Company Conduct of Operations Manual: GOCO cross-cultivation committee. Revision 1, Operational excellence task force

    Energy Technology Data Exchange (ETDEWEB)

    1991-11-01

    Conduct of Operations is a set of standards which establishes an overall philosophy for achieving excellence in the operation of DOE facilities. These standards have application in many facets of our business and shall be considered by each organization that conducts or supports Operations in their efforts to improve overall organizational performance. The formality and accuracy resulting from the implementation of the elements of this manual will enhance safe operations and result in a higher quality product. The elements of the Conduct of Operations Requirements for DOE Facilities (DOE 5480.19) are tools to do our work. In like manner the tools and methods given in the Maintenance Management Program (DOE 4330.3A) are complementary and are to be used to the fullest. These DOE documents taken together and integrated into site implementation provide the framework for well operated facilities committed to excellence and not just compliance. The goal of this manual is to promote greater ownership and accountability by each individual worker and supervisor. Evidence of our success will include accountability by workers on the floor and in technical inquisitiveness at all levels. Striving for excellence involves all of us and we should not wait for someone else to find our problems.

  9. Computer system for monitoring power boiler operation

    Energy Technology Data Exchange (ETDEWEB)

    Taler, J.; Weglowski, B.; Zima, W.; Duda, P.; Gradziel, S.; Sobota, T.; Cebula, A.; Taler, D. [Cracow University of Technology, Krakow (Poland). Inst. for Process & Power Engineering

    2008-02-15

    The computer-based boiler performance monitoring system was developed to perform thermal-hydraulic computations of the boiler working parameters in an on-line mode. Measurements of temperatures, heat flux, pressures, mass flowrates, and gas analysis data were used to perform the heat transfer analysis in the evaporator, furnace, and convection pass. A new construction technique of heat flux tubes for determining heat flux absorbed by membrane water-walls is also presented. The current paper presents the results of heat flux measurement in coal-fired steam boilers. During changes of the boiler load, the necessary natural water circulation cannot be exceeded. A rapid increase of pressure may cause fading of the boiling process in water-wall tubes, whereas a rapid decrease of pressure leads to water boiling in all elements of the boiler's evaporator - water-wall tubes and downcomers. Both cases can cause flow stagnation in the water circulation leading to pipe cracking. Two flowmeters were assembled on central downcomers, and an investigation of natural water circulation in an OP-210 boiler was carried out. On the basis of these measurements, the maximum rates of pressure change in the boiler evaporator were determined. The on-line computation of the conditions in the combustion chamber allows for real-time determination of the heat flowrate transferred to the power boiler evaporator. Furthermore, with a quantitative indication of surface cleanliness, selective sootblowing can be directed at specific problem areas. A boiler monitoring system is also incorporated to provide details of changes in boiler efficiency and operating conditions following sootblowing, so that the effects of a particular sootblowing sequence can be analysed and optimized at a later stage.

  10. New FORTRAN computer programs to acquire and process isotopic mass spectrometric data: Operator`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.H.; McKown, H.S.

    1993-09-01

    This TM is one of a pair that describes ORNL-developed software for acquisition and processing of isotope ratio mass spectral data. This TM is directed at the laboratory analyst. No technical knowledge of the programs and programming is required. It describes how to create and edit files, how to acquire and process data, and how to set up files to obtain the desired results. The aim of this TM is to serve as a utilitarian instruction manual, a {open_quotes}how to{close_quotes} approach rather than a {open_quotes}why?{close_quotes}

  11. NCC simulation model. Phase 2: Simulating the operations of the Network Control Center and NCC message manual

    Science.gov (United States)

    Benjamin, Norman M.; Gill, Tepper; Charles, Mary

    1994-01-01

    The network control center (NCC) provides scheduling, monitoring, and control of services to the NASA space network. The space network provides tracking and data acquisition services to many low-earth orbiting spacecraft. This report describes the second phase in the development of simulation models for the FCC. Phase one concentrated on the computer systems and interconnecting network.Phase two focuses on the implementation of the network message dialogs and the resources controlled by the NCC. Performance measures were developed along with selected indicators of the NCC's operational effectiveness.The NCC performance indicators were defined in terms of the following: (1) transfer rate, (2) network delay, (3) channel establishment time, (4) line turn around time, (5) availability, (6) reliability, (7) accuracy, (8) maintainability, and (9) security. An NCC internal and external message manual is appended to this report.

  12. Operating manual for hybrid thermosyphons at the Gakona Power Plant, Alaska. Special report

    Energy Technology Data Exchange (ETDEWEB)

    Haynes, F.D.; Crory, F.C.; Knuth, K.V.; Quinn, W.F.

    1994-03-01

    A power plant building was constructed in 1990 at an over-the-horizon radar site in Gakona, Alaska. Since it was built on permafrost, thermal protection between the building and the underlying permafrost was included in the design, which included rigid board insulation and hybrid thermosyphons placed in the gravel fill under the building. Soil temperature is monitored with eight thermistor strings placed under and at the building perimeter. This manual describes the steps that must be taken to ensure foundation stability, including directions on when to use the thermosyphons in the active, mechanical refrigeration mode. A data acquisition system using a computer-controlled datalogger is described.

  13. Rise Time. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Carnegie, John W.

    The rise time test (along with the settleometer procedure) is used to monitor sludge behavior in the secondary clarifier of an activated sludge system. The test monitors the effect of the nitrification/denitrification process and aids the operator in determining optimum clarifier sludge detention time and, to some extent, optimum degree of…

  14. Manual on SFR R and D and Technology Monitoring System Based on Enterprise Project Management Solution

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Uk; Lee, Yong Bum; Won, Byung Chool; Kim, Young In; Hahn, Do Hee

    2008-04-15

    This report is a manual on enterprise project management solution for R and D and technology monitoring system that is applicable for managing the generation IV sodium-cooled fast reactor development. The prime goal of this system is to provide project manager with reliable and accurate information of status of progress, performance and resource allocation, and attain traceability and visibility of project implementation for effective project management. This report is composed of the three part. The first part is an introduction on microsoft project professional software that was used to monitor the progress, evaluate the results and analyze the resource distribution of the activities. The second makes a description of project plan and control, and the third part describes on collaboration and teamwork.

  15. The effects of operator position, pallet orientation, and palletizing condition on low back loads in manual bag palletizing operations.

    Science.gov (United States)

    Gallagher, Sean; Heberger, John R

    2015-05-01

    Many mining commodities are packaged and shipped using bags. Small bags are typically loaded onto pallets for transport and require a significant amount of manual handling by workers. This specific task of manual bag handling has been associated with the development of musculoskeletal disorders (MSDs), especially low back disorders. This study evaluates the biomechanical demands of different work layouts when performing manual palletizing of small bags, and evaluates the biomechanical stresses associated with different stacking techniques. Results indicate that peak forward bending moments as well as spinal compression and shear forces are higher when the pallet is situated at the side of the conveyor as opposed to the end of the conveyor. At low levels of the pallet, controlled bag placement results in higher peak forward bending moments than stacking at higher levels and when dropping the bag to lower levels. The results of this study will be used to inform the development of an audit tool for bagging operations in the mining industry.

  16. Human machine interface to manually drive rhombic like vehicles in remote handling operations

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Pedro; Vale, Alberto [Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal); Ventura, Rodrigo [Institute for Systems and Robotics, Instituto Superior Tecnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal)

    2015-07-01

    In the thermonuclear experimental reactor ITER, a vehicle named CTS is designed to transport a container with activated components inside the buildings. In nominal operations, the CTS is autonomously guided under supervision. However, in some unexpected situations, such as in rescue and recovery operations, the autonomous mode must be overridden and the CTS must be remotely guided by an operator. The CTS is a rhombic-like vehicle, with two drivable and steerable wheels along its longitudinal axis, providing omni-directional capabilities. The rhombic kinematics correspond to four control variables, which are difficult to manage in manual mode operation. This paper proposes a Human Machine Interface (HMI) to remotely guide the vehicle in manual mode. The proposed solution is implemented using a HMI with an encoder connected to a micro-controller and an analog 2-axis joystick. Experimental results were obtained comparing the proposed solution with other controller devices in different scenarios and using a software platform that simulates the kinematics and dynamics of the vehicle. (authors)

  17. 40 CFR 60.63 - Monitoring of operations.

    Science.gov (United States)

    2010-07-01

    ...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Portland Cement Plants § 60.63 Monitoring of operations. (a) The owner or operator of any portland cement plant subject to...

  18. Citizen Science Air Monitor (CSAM) Operating Procedures

    Science.gov (United States)

    The Citizen Science Air Monitor (CSAM) is an air monitoring system designed for measuring nitrogen dioxide (NO2) and particulate matter (PM) pollutants simultaneously. This self-contained system consists of a CairPol CairClip NO2 sensor, a Thermo Scientific personal DataRAM PM2.5...

  19. Feasibility Study of a Rotorcraft Health and Usage Monitoring System (HUMS): Results of Operator's Evaluation

    Science.gov (United States)

    Romero, Raylund; Summers, Harold; Cronkhite, James

    1996-01-01

    The objective was to evaluate the feasibility of a state-of-the-art health and usage monitoring system (HUMS) to provide monitoring of critical mechanical systems on the helicopter, including motors, drive train, engines, and life-limited components. The implementation of HUMS and cost integration with current maintenance procedures was assessed from the operator's viewpoint in order to achieve expected benefits from these systems, such as enhanced safety, reduced maintenance cost, and increased availability. An operational HUMS that was installed and operated under an independent flight trial program was used as a basis for this study. The HUMS equipment and software were commercially available. Based on the results of the feasibility study, the HUMS used in the flight trial program generally demonstrated a high level of reliability in monitoring the rotor system, engines, drive train, and life-limited components. The system acted as a sentinel to warn of impending failures. A worn tail rotor pitch bearing was detected by HUMS, which had the capability for self testing to diagnose system and sensor faults. Examples of potential payback to the operator with HUMS were identified, including reduced insurance cost through enhanced safety, lower operating costs derived from maintenance credits, increased aircraft availability, and improved operating efficiency. The interfacing of HUMS with current operational procedures was assessed to require only minimal revisions to the operator's maintenance manuals. Finally the success in realizing the potential benefits from HUMS technology was found to depend on the operator, helicopter manufacturer, regulator (FAA), and HUMS supplier working together.

  20. REPETITIVE MANUAL OPERATIONS IN THE DAIRY SECTOR: ANALYSES AND CRITERIA FOR INTERVENTION

    Directory of Open Access Journals (Sweden)

    Pier Riccardo Porceddu

    2008-03-01

    Full Text Available For the health of workers it is necessary to consider, together with traditional risks (noise, vibrations, microclimate etc., risks deriving from repetitive movements, which can generate muscolo-skeletal disorders. These risks can be found in artisan dairies, where the limited use of machinery and the rapid successive passages for processing the milk require high-frequency repetitive manual movements. The study analysed the risks of repetitive movements for workers in a dairy, using the OCRA method. Various risk-involving operations emerged, which require the re-planning of the workplace. The proposed interventions have not involved high costs for the dairy, or a loss of productivity.

  1. Population-based register of acute myocardial infarction: manual of operations

    DEFF Research Database (Denmark)

    Madsen, Mette; Gudnason, Vilmundur; Pajak, Andrzej

    2007-01-01

    Set) to build up comparable and reliable indicators (attack rate and case fatality) for the surveillance of acute myocardial infarction/acute coronary syndrome at population level.This manual of operations is intended for health professionals and policy makers and provides a standardized and simple......-defined geographical and administrative area or region representative of the whole country for which population data and vital statistics (mortality and hospital discharge records at minimum) are routinely collected and easily available each year. All cases among residents should be recorded even if the case occurs...

  2. The Conversion of a Zimbabwean Processing Plant from Manual to Smart Operation

    Institute of Scientific and Technical Information of China (English)

    Michael; Collier; Ernest; Bhero

    2010-01-01

    <正>The automation of several key processes in a factory in Zimbabwe is described.The plant is a producer of bolts and nails for the southern Africa region.Being built in the 1950s,the equipment was intended for manual operation.To improve efficiency and reduce overhead costs, this project was commissioned to add electronic intelligence to some of the processing equipment.In particular the conversion of forging furnaces to computer control and the intelligent implementation of heat-treatment processes are described.Results of the project in economic and quality terms are presented.

  3. 40 CFR 146.13 - Operating, monitoring and reporting requirements.

    Science.gov (United States)

    2010-07-01

    ...; (iii) Periodic monitoring of the ground water quality in the first aquifer overlying the injection zone; (iv) Periodic monitoring of the ground water quality in the lowermost USDW; and (v) Any additional... Applicable to Class I Wells § 146.13 Operating, monitoring and reporting requirements. (a)...

  4. Operating experience review of an INL gas monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, Lee C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); DeWall, K. G. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Herring, J. S. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-12

    This article describes the operations of several types of gas monitors in use at the Idaho National Laboratory (INL) High Temperature Electrolysis Experiment (HTE) laboratory. The gases monitored in the lab room are hydrogen, carbon monoxide, carbon dioxide, and oxygen. The operating time, calibration, and both actual and unwanted alarms are described. The calibration session time durations are described. In addition, some simple calculations are given to estimate the reliability of these monitors and the results are compared to operating experiences of other types of monitors.

  5. Single-operator multiparameter metabolic analyzer (SOMMA) for total carbon dioxide (C{sub T}) with coulometric detection. Operator`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.M.

    1992-01-01

    This manual contains the presently known information about using the SOMMA (Single-Operator Multiparameter Metabolic Analyzer) -Coulometer system for total carbon dioxide (C{sub T}) analysis of seawater samples. Being Version 1.0, it is preliminary and will be revised as new information is obtained from SOMMA users. As part of a US Department of Energy (DOE) program to conduct a global survey of CO{sub 2} in the ocean in conjunction with the World Ocean Circulation Experiment (WOCE) Hydrographic Program and Joint Global Ocean Flux Study, C{sub T} measurements are being made with SOMMA systems by several US and foreign laboratories. The purpose of the manual and future versions is to improve the accuracy and precision of seawater analysis through better documentation of methods and to facilitate communication of new operating procedures.

  6. Manual vibrocompression and nasotracheal suctioning in post-operative period of infants with heart deffects

    Directory of Open Access Journals (Sweden)

    Maíra Seabra de Assumpção

    2013-12-01

    Full Text Available OBJECTIVE: To evaluate the impact of manual vibrocompression and nasotracheal suctioning on heart (hr and respiratory (rr rates, peripheral oxygen saturation (SpO2, pain and respiratory distress in infants in the postoperative period of a cardiac surgery. METHODS: Randomized controlled trial, in which the assessments were performed by the same physiotherapist in two moments: before and after the procedure. The infants were randomly divided into two groups: Intervention (IG, with manual chest vibrocompression, nasotracheal suctioning and resting; and Control CG, with 30 minutes of rest. Cardiorespiratory data (SpO2; hr; rr were monitored and the following scales were used: Neonatal Infant Pain Scale (NIPS, for pain evaluation, and Bulletin of Silverman-Andersen (BSA, for respiratory distress assessment. The data were verified by analysis of variance (ANOVA for repeated measures, being significant p<0.05. RESULTS: 20 infants with heart disease, ten in each group (seven acyanotic and three cyanotic were enrolled, with ages ranging from zero to 12 months. In the analysis of the interaction between group and time, there was a significant difference in the variation of SpO2 (p=0.016, without changes in the other variables. Considering the main effect on time, only rr showed a significant difference (p=0.001. As for the group main effect, there were no statistical differences (SpO2 - p=0.77, hr - p=0.14, rr - p=0.17, NIPS - p=0.49 and BSA - p=0.51 . CONCLUSIONS: The manual vibrocompression and the nasotracheal suctioning applied to infants in postoperative of cardiac surgery did not altered SpO2 and rr, and did not trigger pain and respiratory distress. [Brazilian Registry of Clinical Trials (ReBEC: REQ: 1467].

  7. PC and monitor night status: Power management enabling and manual turn-off

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Bruce; Meier, Alan; Piette, Mary Ann

    1998-07-30

    While office equipment accounts for about 7 percent of commercial building energy use, this reflects considerable energy savings from the use of automatic power management. Most of these savings were gained through the use of low-power modes that meet the criteria of the U.S. EPA's Energy Star program. Despite this success, there are large amounts of additional savings that could be gained if all equipment capable of power management use were enabled and functioning. A considerable portion of equipment is not enabled for power management at all, enabled only partially, or is enabled but prevented from functioning. Additional savings could be gained if more equipment were turned off at night manually. We compiled results from 17 studies from the office equipment literature addressing PCs and monitors. Some factors important for annual energy use, such as power levels, have been documented elsewhere and are not covered. We review methods for estimating office equipment use patterns and energy use, and present findings on night status--power management and manual turn-off rates. In early studies, PC power management was often found to function in 25 percent or less of the Energy Star compliant units (10 percent of all PCs). However, recent assessments have found higher rates, and we estimate that for Energy Star models, 35 percent of PC CPUs and 65 percent of PC monitors are enabled for power management. While the data lack statistical rigor, they can be used to estimate the magnitude of current and potential power management savings, which we did for major types of office equipment. The data also make clear that the topic of enabling rates, and the factors which influence them, deserve greater scrutiny.

  8. Simulation model for wind energy storage systems. Volume II. Operation manual. [SIMWEST code

    Energy Technology Data Exchange (ETDEWEB)

    Warren, A.W.; Edsinger, R.W.; Burroughs, J.D.

    1977-08-01

    The effort developed a comprehensive computer program for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic). An acronym for the program is SIMWEST (Simulation Model for Wind Energy Storage). The level of detail of SIMWEST is consistent with a role of evaluating the economic feasibility as well as the general performance of wind energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. Volume II, the SIMWEST operation manual, describes the usage of the SIMWEST program, the design of the library components, and a number of simple example simulations intended to familiarize the user with the program's operation. Volume II also contains a listing of each SIMWEST library subroutine.

  9. Manually operated pile driver for use in the south Iraqi Marshlands

    Directory of Open Access Journals (Sweden)

    Massimo Monti

    2013-09-01

    Full Text Available Anthropizations are necessary to implement the maintenance, recovery and utilization of wetlands. These interventions should be sustainable in every sense, in particular they should be marked by a low environmental impact. In general this aim can be achieved by using natural materials and carrying out procedures minimally invasive. In Developing Countries the latter point is often supported by the lack of equipment and energy availability, normally obtainable in Industrialized Countries. In practice, to build micro-infrastructures with the above said characteristics, it is normally necessary to drive poles, in our case in wood, in marshland’s soil. In order to accomplish this task a manually operated pile driver was designed and built. To operate in the water, a floating pier consisting of removable modular elements was also designed.

  10. Operant Conditioning of Mental Retardates' Visual Monitoring.

    Science.gov (United States)

    Perryman, Roy E.; And Others

    1981-01-01

    To study improvement of visual monitoring of retardates, specialized training methods backed up by incentives were used. The extent to which these training techniques might be expected to produce results which would generalize was explored. Subjects were eight female mental retardates (ages 15-22) with IQs from 38 to 69. (Author/SJL)

  11. Analysis of operational comfort in manual tasks using human force manipulability measure.

    Science.gov (United States)

    Tanaka, Yoshiyuki; Nishikawa, Kazuo; Yamada, Naoki; Tsuji, Toshio

    2015-01-01

    This paper proposes a scheme for human force manipulability (HFM) based on the use of isometric joint torque properties to simulate the spatial characteristics of human operation forces at an end-point of a limb with feasible magnitudes for a specified limb posture. This is also applied to the evaluation/prediction of operational comfort (OC) when manually operating a human-machine interface. The effectiveness of HFM is investigated through two experiments and computer simulations of humans generating forces by using their upper extremities. Operation force generation with maximum isometric effort can be roughly estimated with an HFM measure computed from information on the arm posture during a maintained posture. The layout of a human-machine interface is then discussed based on the results of operational experiments using an electric gear-shifting system originally developed for robotic devices. The results indicate a strong relationship between the spatial characteristics of the HFM and OC levels when shifting, and the OC is predicted by using a multiple regression model with HFM measures.

  12. Manual lymphatic drainage and therapeutic ultrasound in liposuction and lipoabdominoplasty post-operative period

    Directory of Open Access Journals (Sweden)

    Igor F. B. Masson

    2014-01-01

    Full Text Available Background: Physiotherapy in the plastic surgery post-operative (PO is essential to provide means for an adequate and fast recovery as it restores function through the use of physiotherapeutic procedures. Aim: The aim of the following study is to verify the effects of the association between the manual lymphatic drainage and the therapeutic ultrasound on pain, oedema and the tissue fibrosis in liposuction and lipoabdominoplasty PO. Design: This is a clinical trial prospective. Materials and Methods: Eighteen women aged between 18 and 60 years participated in this study, in the late PO period following lipoabdominoplasty or liposuction in the abdomen, flanks and lower trunk, which showed tissue fibrosis of the flanks and abdomen regions. They were divided into two groups: Liposuction group and lipoabdominoplasty group. A total of twelve sessions of therapeutic ultrasound followed by the manual lymphatic drainage were performed. The patients were assessed with regard to pain, oedema and tissue fibrosis in different moments: Initial assessment, during assessment and final assessment through the application of the protocol of evaluation of cysts fibrosis levels. Statistical Analysis: The test of equality for two proportions and the confidence interval test for mean to evaluate the distribution of variables. The significance level adopted for statistical tests was 5% (P < 0.05. Results: There was a statistically significant reduction of pain, swelling and tissue fibrosis in both groups. Conclusion: the association between manual lymphatic drainage and the therapeutic ultrasound reduced the swelling and the tissue fibrosis and made pain disappear in liposuction and lipoabdominoplasty PO period.

  13. 40 CFR 146.23 - Operating, monitoring, and reporting requirements.

    Science.gov (United States)

    2010-07-01

    ...)); and (5) Hydrocarbon storage and enhanced recovery may be monitored on a field or project basis rather... information may be included by reference. (2) Owners or operators of hydrocarbon storage and enhanced recovery... fluid disposal operations; (ii) Monthly for enhanced recovery operations; (iii) Daily during the...

  14. Operational modes, health, and status monitoring

    Science.gov (United States)

    Taljaard, Corrie

    2016-08-01

    System Engineers must fully understand the system, its support system and operational environment to optimise the design. Operations and Support Managers must also identify the correct metrics to measure the performance and to manage the operations and support organisation. Reliability Engineering and Support Analysis provide methods to design a Support System and to optimise the Availability of a complex system. Availability modelling and Failure Analysis during the design is intended to influence the design and to develop an optimum maintenance plan for a system. The remote site locations of the SKA Telescopes place emphasis on availability, failure identification and fault isolation. This paper discusses the use of Failure Analysis and a Support Database to design a Support and Maintenance plan for the SKA Telescopes. It also describes the use of modelling to develop an availability dashboard and performance metrics.

  15. Monitoring, Operational Manager Efforts and Inventory Policy

    OpenAIRE

    Alfaro, J A; Tribó, J. (Josep)

    2003-01-01

    Operations managers are becoming more important in modern corporations. They do not only care on firms’ inventory management but also they are involved in firms’ strategic decisions. Within this setting we ask about the consequences in the inventory policy of this new role undertaken by these managers. To do so, we develop a model where a firm’s Operations Manager can devote some efforts to develop non-inventory related activities. These efforts, although non-verifiable, may be known with a c...

  16. Operating Experiences of a Loss of Voltage Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun-Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    Loss of voltage (LOV) events continue to occur due to inadequate work management and random human errors. On February 26, 2015, regulators analyzed the root causes of LOV events and presented the results for the nuclear industry. Currently, KHNP uses a risk monitoring program, which is named 'LOV Monitor', for LOV prevention during pilot plant outages. This review introduces the operation experiences of LOV Monitor based on the evaluation results of a real event. The operation experiences of LOV Monitor in the pilot plants confirmed that this program could detect and reduce LOV possibilities from scheduling errors such as the simultaneous maintenance of energized trains and de-energized trains considering the physical conditions of the power circuit breakers. However, a maintenance culture that heeds the risk monitoring result must be strengthened in order to obtain substantial effects through applying LOV Monitor to the outage.

  17. A Course on Operational Considerations in Wastewater Treatment Plant Design. Instructor's Manual.

    Science.gov (United States)

    Cooper, John W.; And Others

    This manual contains 17 instructional units (sequenced to correspond to parallel chapters in a student's manual) focusing on upgrading the design of wastewater plant facilities and serving as a reference source for establishing criteria for upgrading wastewater treatment plants. The manual also furnishes information for modifying plant design to…

  18. Design of a Pneumatic Tool for Manual Drilling Operations in Confined Spaces

    Science.gov (United States)

    Janicki, Benjamin

    This master's thesis describes the design process and testing results for a pneumatically actuated, manually-operated tool for confined space drilling operations. The purpose of this device is to back-drill pilot holes inside a commercial airplane wing. It is lightweight, and a "locator pin" enables the operator to align the drill over a pilot hole. A suction pad stabilizes the system, and an air motor and flexible drive shaft power the drill. Two testing procedures were performed to determine the practicality of this prototype. The first was the "offset drill test", which qualified the exit hole position error due to an initial position error relative to the original pilot hole. The results displayed a linear relationship, and it was determined that position errors of less than .060" would prevent the need for rework, with errors of up to .030" considered acceptable. For the second test, a series of holes were drilled with the pneumatic tool and analyzed for position error, diameter range, and cycle time. The position errors and hole diameter range were within the allowed tolerances. The average cycle time was 45 seconds, 73 percent of which was for drilling the hole, and 27 percent of which was for positioning the device. Recommended improvements are discussed in the conclusion, and include a more durable flexible drive shaft, a damper for drill feed control, and a more stable locator pin.

  19. Operator coil monitoring Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Erhart, M.F.

    1995-05-16

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring and control of the Programmable Logic Controller (PLC) abort coils from the Master and RSS stations will be systematically tested during performance of this procedure. It should be noted that these are not physical abort coils but software coils controlled by the software`s ladder logic. The readiness of the DACS to properly interface with the ENRAF wire level gauge installed in the SY-101 storage tank will also be tested. During this test, a verification of all abort coil indications will be conducted at the DACS Development Facility in the 306E Building by injecting an input signal for each DACS sensor that has an associated abort coil until the abort coil actuates, and then ensuring that the status of the abort coil indicated at the Master and RSS stations is correct. Each abort coil will also be tested to ensure that the ``ENABLE`` and ``DISABLE`` controls from the Master and RSS stations function correctly, and only with the use of proper passwords.

  20. General Operational Procedure for Pedestrian Radiation Portal Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Belooussov, Andrei V. [Los Alamos National Laboratory

    2012-08-08

    This document outlines the basic conduct of operation (CONOPS) for a pedestrian radiation portal monitor (RPM), provided that the CONOPS is not facility or RPM specific and that it is based on a general understanding of a pedestrian RPM operation. The described CONOPS for a pedestrian RPM is defined by: (1) RPM design and operational characteristics, (2) type of pedestrian traffic, and (3) goal for RPM installation. Pedestrian RPMs normally are deployed for the continuous monitoring of individuals passing through point of control to detect the unauthorized traffic of radioactive/nuclear materials. RPMs generally are designed to detect gamma- and neutron-emitting materials.

  1. Operators Manual and Technical Reference for the Z-Beamlet Phase Modulation Failsafe System: Version 1.

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Darrell J.

    2014-09-01

    The need for pulse energies exceeding 4 kJ and pulse lengths [?] 2 ns in Sandia's Z-Beamlet laser (ZBL) requires that the single-frequency spectrum of its fiber-laser master oscillator be converted to a phase modulated spectrum with a modulation in dex [?] 5. Because accidental injection of single-frequency light into ZBL could result i n damage to optical materials from transverse stimulated Brillouin scattering, the presence of phase modulated (PM) light must be monitored by a reliable failsafe system that can stop a las er shot within of a few 10's of ns following a failure of the PM system. This requirement is met by combining optical heterodyne detection with high-speed electronics to indicate the pres ence or absence of phase modulated light. The transition time for the failsafe signal resultin g from a sudden failure using this technique is approximately 35 ns. This is sufficiently short to safely stop a single-frequency laser pulse from leaving ZBL's regenerative amplifier with a n approximately 35 ns margin of safety. This manual and technical reference contains detai led instructions for daily use of the PM failsafe system and provides enough additional informat ion for its maintenance and repair.

  2. HGP-A Wellhead Generator, Proof-Of-Feasibility Project 3 MW Wellhead Generator, Start-Up Training and Operating Manual

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-01

    The start-up manual is an information aid to initially familiarize plant operators with the plant operation and later be used as a reference manual while operating the plant. This start-up manual is supplemented by the Plant Data Manual which contains a detailed description of the philosophy of operation and equipment characteristics. The sequencing herein presents the necessary operating procedures which must be followed in order that a smooth start-up is obtained. The sequence includes, first conditioning the well and stabilizing the steam/water separations, and then bringing the operating machinery on line. The Piping and Instrumentation Diagrams and Electrical Drawings are included under Section 12.0 and are frequently referred to in the text. Information for ''trouble-shooting'' is provided in the maintenance and operations manuals on all the equipment.

  3. The human operator in manual preview tracking /an experiment and its modeling via optimal control/

    Science.gov (United States)

    Tomizuka, M.; Whitney, D. E.

    1976-01-01

    A manual preview tracking experiment and its results are presented. The preview drastically improves the tracking performance compared to zero-preview tracking. Optimal discrete finite preview control is applied to determine the structure of a mathematical model of the manual preview tracking experiment. Variable parameters in the model are adjusted to values which are consistent to the published data in manual control. The model with the adjusted parameters is found to be well correlated to the experimental results.

  4. 33 CFR 157.206 - Dedicated Clean Ballast Tanks Operations Manual for U.S. tank vessels: Submission.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels General § 157.206 Dedicated Clean Ballast Tanks Operations Manual for U.S. tank...

  5. A Training Manual in Conducting a Workshop in the Design, Construction, Operation, Maintenance and Repair of Hydrams.

    Science.gov (United States)

    Peace Corps, Washington, DC. Office of Programming and Training Coordination.

    This manual presents a comprehensive training design, suggested procedures, and materials for conducting a workshop in the design, construction, operation, maintenance, and repair of hydrams, and in the planning and implementation of hydram projects. Hydrams (hydraulic rams, hydraulic ram pumps, automatic hydraulic ram pumps, rams) are devices…

  6. Manual of electric power conservation. Residential co-operatives buildings; Manual de conservacao de energia eletrica. Condominios residenciais

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-01-01

    Procedures to electric power consumption optimization, and energy conservation on residential co-operative buildings are presented. Lighting consumption profiles, lamps and its lighting characteristic table, internal program to energy conservation, some information about energy consumption optimization, water consumption, energy costs, performance evaluation and safety patterns on electric plants are discussed. 25 figs., 5 tabs.

  7. Operation and maintenance manual for septic holding tank system for project W-519, two double-wide construction support trailers

    Energy Technology Data Exchange (ETDEWEB)

    MORTIMER, C.S.

    1999-08-25

    This manual was prepared to provide detailed information for the operation and maintenance of the sanitary wastewater holding system. This procedure sets forth system operations which include type and frequency of required maintenance as well as system failure response procedures. The system consists of a sanitary sewage holding tank, two alarms and appurtenances necessary to provide a functional system. The maximum daily design flow is 696 liters. The holding tank is located as shown on the site plan.

  8. A Course on Operational Considerations in Wastewater Treatment Plant Design. Student Manual.

    Science.gov (United States)

    Stottler, Stag and Associates, San Antonio, TX.

    This manual was designed to furnish information for upgrading the design of wastewater treatment plant facilities and to serve as a resource for establishing criteria for upgrading these plants. The manual also furnishes information for modifying plant design to compensate for current organic and hydraulic overloads and/or to meet more stringent…

  9. Monitoring operational data production applying Big Data tooling

    Science.gov (United States)

    Som de Cerff, Wim; de Jong, Hotze; van den Berg, Roy; Bos, Jeroen; Oosterhoff, Rijk; Klein Ikkink, Henk Jan; Haga, Femke; Elsten, Tom; Verhoef, Hans; Koutek, Michal; van de Vegte, John

    2015-04-01

    Within the KNMI Deltaplan programme for improving the KNMI operational infrastructure an new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. All applications are individually monitored by different applications, complicating root cause and impact analysis. Also, the underlying hardware and network is monitored separately using Zabbix. Goal of the new system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what other products will be effected). The PRISMA system will make it possible to dispose all the existing monitoring applications, providing one interface for monitoring the data production. For modeling the production chain, the Neo4j Graph database is used to store and query the model. The model can be edited through the PRISMA web interface, but is mainly automatically provided by the applications and systems which are to be monitored. The graph enables us to do root case and impact analysis. The graph can be visualized in the PRISMA web interface on different levels. Each 'monitored object' in the model will have a status (OK, error, warning, unknown). This status is derived by combing all log information available. For collecting and querying the log information Splunk is used. The system is developed using Scrum, by a multi-disciplinary team consisting of analysts, developers, a tester and interaction designer. In the presentation we will focus on the lessons learned working with the 'Big data' tooling Splunk and Neo4J.

  10. Variability of exposure and estimation of cumulative exposure in a manually operated coal mine

    Energy Technology Data Exchange (ETDEWEB)

    Mamuya, S.H.D.; Bratveit, M.; Mwaiselage, J.; Moen, B.E. [University of Bergen, Bergen (Norway). Center for International Health

    2006-10-15

    This study aims at estimating variability in exposure to respirable dust and assessing whether the a priori grouping by job team is appropriate for an exposure-response study on respiratory effects among workers in a manually operated coal mine in Tanzania. Furthermore, estimated exposure levels were used to calculate cumulative exposure. Full-shift personal respirable dust samples (n = 204) were collected from 141 randomly chosen workers at underground and surface work sites. The geometric mean exposure for respirable dust varied from 0.07 mg m{sup -3} for office workers to 1.96 mg m{sup -3} for the development team. The analogous range of respirable quartz exposure was 0.006-0.073 mg m{sup -3}. Variance components were estimated using random effect models. For most job teams the within-worker variance component was considerably higher than the between-worker variance component. For respirable dust the estimated attenuation of the linear exposure-response relationship was low (5.9%) when grouping by job team. Grouping by job team was considered appropriate for studying the association between current dust exposure and respiratory effects. Based on the estimated worker-specific mean exposure in the job teams, the arithmetic mean cumulative exposure for the 299 workers who participated in the epidemiological part of the study was 38.1 mg. yr m{sup -3} for respirable dust and 2.0 mg. yr m{sup -3} for quartz.

  11. Hydrogen and Oxygen Gas Monitoring System Design and Operation

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader; Kevin G. DeWall; J. Stephen Herring

    2007-06-01

    This paper describes pertinent design practices of selecting types of monitors, monitor unit placement, setpoint selection, and maintenance considerations for gas monitors. While hydrogen gas monitors and enriched oxygen atmosphere monitors as they would be needed for hydrogen production experiments are the primary focus of this paper, monitors for carbon monoxide and carbon dioxide are also discussed. The experiences of designing, installing, and calibrating gas monitors for a laboratory where experiments in support of the DOE Nuclear Hydrogen Initiative (NHI) are described along with codes, standards, and regulations for these monitors. Information from the literature about best operating practices is also presented. The NHI program has two types of activities. The first, near-term activity is laboratory and pilot-plant experimentation with different processes in the kilogram per day scale to select the most promising types of processes for future applications of hydrogen production. Prudent design calls for indoor gas monitors to sense any hydrogen leaks within these laboratory rooms. The second, longer-term activity is the prototype, or large-scale plants to produce tons of hydrogen per day. These large, outdoor production plants will require area (or “fencepost”) monitoring of hydrogen gas leaks. Some processes will have oxygen production with hydrogen production, and any oxygen releases are also safety concerns since oxygen gas is the strongest oxidizer. Monitoring of these gases is important for personnel safety of both indoor and outdoor experiments. There is some guidance available about proper placement of monitors. The fixed point, stationary monitor can only function if the intruding gas contacts the monitor. Therefore, monitor placement is vital to proper monitoring of the room or area. Factors in sensor location selection include: indoor or outdoor site, the location and nature of potential vapor/gas sources, chemical and physical data of the

  12. RadMonitor: radiology operations data mining in real time.

    Science.gov (United States)

    Chen, Richard; Mongkolwat, Pattanasak; Channin, David S

    2008-09-01

    This paper describes the web-based visualization interface of RadMonitor, a platform-independent web application designed to help manage the complexity of information flow within a health care enterprise. The system eavesdrops on Health Layer 7 traffic and parses statistical operational information into a database. The information is then presented to the user as a treemap--a graphical visualization scheme that simplifies the display of hierarchical information. While RadMonitor has been implemented for the purpose of analyzing radiology operations, its XML backend allows it to be reused for virtually any other hierarchical data set.

  13. Therapeutic concordance of two portable monitors and two routine automatic oral anticoagulant monitoring systems using as reference the manual prothrombin time technique.

    Science.gov (United States)

    Vacas, Marta; Lafuente, Pedro José; Unanue, Iciar; Santos, Mónica; Iriarte, Jose Antonio

    2003-01-01

    Two models of capillary blood prothrombin time (PT) monitoring systems were evaluated for analytical performance and then compared with two routine PT systems using the reference manual technique and a high-sensitivity thromboplastin. Two sets of 60 and 80 plasmas were analyzed from anticoagulated patients stabilized over 3 months in an INR range 2-3.5 for therapy. Capillary PT determination was performed in two portable monitors, CoaguChek S and CoaguChek PT (Roche Diagnostics), and plasma automatic methods were Neoplastine/STA (Diagnostics Stago) and PT-FibrinogenHsPlus/ACL7000 (Instrumental Laboratories). Thromboplastin Bilbao (TBi), an in-house high-sensitivity rabbit thromboplastin (ISI=1.08), recommended as the reference reagent by an External Spanish Oral Anticoagulant Quality Assessment, was used in the PT manual technique. The two monitors' coefficients of correlation with the reference system were 0.74 for CoaguChek S and 0.81 for CoaguChek PT. The automatic routine systems showed a correlation of 0.92 (Neoplastine/STA) and 0.91 (PT-FbHsPlus/ACL7000). Clinical agreement expressed as the percentage of simple correlation ranged between 75.0% (CoaguChek S) and 88.9% (Neoplastine/STA). The systems having the best kappa index with the manual technique were CoaguChek PT (71.9%) and the Neoplastine/STA system (73%). The routine PT management systems exhibited better correlation and percentage of concordance when using the TBi/manual technique than did the portable monitors, which moreover performed unequally in this regard.

  14. US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K

    Energy Technology Data Exchange (ETDEWEB)

    Gianotto, D.F.; Rope, R.C.; Mondecar, M.; Breckenridge, R.P.; Wiersma, G.B.; Staley, C.S.; Moser, R.S.; Sherwood, R.; Brown, K.W.

    1993-04-01

    Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook for users to be able to make revisions to their own biomonitoring data.

  15. Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Timothy L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates. You must convey all documents describing work to the SNL/NM Project Manager in both hard copy and in an electronic format compatible with the SNL/NM-prescribed CADD and other software packages, and in accordance with a SNL/NM approved standard format. Print all hard copy versions of submitted documents (excluding drawings and renderings) double-sided when practical.

  16. Process control and recovery in the Link Monitor and Control Operator Assistant

    Science.gov (United States)

    Lee, Lorrine; Hill, Randall W., Jr.

    1993-01-01

    This paper describes our approach to providing process control and recovery functions in the Link Monitor and Control Operator Assistant (LMCOA). The focus of the LMCOA is to provide semi-automated monitor and control to support station operations in the Deep Space Network. The LMCOA will be demonstrated with precalibration operations for Very Long Baseline Interferometry on a 70-meter antenna. Precalibration, the task of setting up the equipment to support a communications link with a spacecraft, is a manual, time consuming and error-prone process. One problem with the current system is that it does not provide explicit feedback about the effects of control actions. The LMCOA uses a Temporal Dependency Network (TDN) to represent an end-to-end sequence of operational procedures and a Situation Manager (SM) module to provide process control, diagnosis, and recovery functions. The TDN is a directed network representing precedence, parallelism, precondition, and postcondition constraints. The SM maintains an internal model of the expected and actual states of the subsystems in order to determine if each control action executed successfully and to provide feedback to the user. The LMCOA is implemented on a NeXT workstation using Objective C, Interface Builder and the C Language Integrated Production System.

  17. Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

    Energy Technology Data Exchange (ETDEWEB)

    Fattor, Steven [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2014-06-01

    The manual contains general requirements that apply to nonnuclear and nonexplosive facilities. For design and construction requirements for modifications to nuclear or explosive facilities, see the project-specific design requirements noted in the Design Criteria.

  18. Monitoring noise from aircraft operations in the vicinity of airports

    Science.gov (United States)

    Eldred, Kenneth Mck.

    This paper presents an overview of a proposed Society of Automotive Engineers Aerospace Recommended Practice (ARP4721) with this title. The ARP is intended to provide engineering methods for measuring the noise from aircraft operations in the vicinity of airports for a variety of potential users and purposes. It uses the A-weighted Sound Level (Slow) and quantities derived from its time history as the principal descriptor of aircraft noise. It represents an evolutionary growth from the airport noise monitoring experience over the past three decades. It is intended to cover both unattended multi-channel noise measurement systems used for routine monitoring and attended systems used for special monitoring or for other measurement purposes. It contains recommended methods for the acquisition of non-acoustical data and requirements for systems that acquire acoustical data and their processing. It provides information on temporal and spatial sampling with respect to sampling design and errors, and discusses several applications for its use in monitoring.

  19. Pairing Essential Climate Science with Sustainable Energy Information: the "EARTH-The Operators' Manual" experiment

    Science.gov (United States)

    Akuginow, E.; Alley, R. B.; Haines-Stiles, G.

    2010-12-01

    Social science research on the effective communication of climate science suggests that today's audiences may be effectively engaged by presenting information about Earth's climate in the context of individual and community actions that can be taken to increase energy efficiency and to reduce carbon emissions. "EARTH-The Operators' Manual" (ETOM) is an informal science education and outreach project supported by NSF, comprising three related components: a 3-part broadcast television mini-series; on-site outreach at 5 major science centers and natural history museums strategically located across the USA; and a website with innovative social networking tools. A companion tradebook, written by series presenter and Penn State glaciologist Richard Alley, is to be published by W. W. Norton in spring 2011. Program 1, THE BURNING QUESTION, shows how throughout human history our need for energy has been met by burning wood, whale oil and fossil fuels, but notes that fossil fuels produce carbon dioxide which inevitably change the composition of Earth's atmosphere. The program uses little known stories (such as US Air Force atmospheric research immediately after WW2, looking at the effect of CO2 levels on heat-seeking missiles, and Abraham Lincoln's role in the founding of the National Academy of Sciences and the Academy's role in solving navigation problems during the Civil War) to offer fresh perspectives on essential but sometimes disputed aspects of climate science: that today's levels of CO2 are unprecedented in the last 400,000 and more years; that human burning of fossil fuel is the scientifically-proven source, and that multiple lines of evidence show Earth is warming. Program 2, TEN WAYS TO KEEP TEN BILLION SMILING, offers a list of appealing strategies (such as "Get Rich and Save the World": Texas & wind energy, and "Do More with Less": how glow worms make cool light without waste heat, suggesting a role for organic LEDs) to motivate positive responses to the

  20. An Autonomous Long Range Monitoring System For Emergency Operators

    CERN Document Server

    Lanati, Matteo; Secco, Emanuele Lindo; Magenes, Giovanni; Gamba, Paolo

    2011-01-01

    Miniaturization and portability of new electronics lead up to wearable devices embedded within garments: a European program called ProeTEX developed multi-purpose sensors integrated within emergency operators' garments in order to monitor their health state and the surrounding environment. This work deals with the development of an autonomous Long Range communication System (LRS), suitable to transmit data between operators' equipment and the local command post, where remote monitoring software is set up. The LRS infrastructure is based on Wi-Fi protocol and modular architecture. Field tests carried out on the developed prototype showed a high reliability in terms of correctly exchanged data and recovering capabilities in case of temporary disconnection, due to the operator's movements.

  1. GNSS-based operational monitoring devices for forest logging operation chains

    Directory of Open Access Journals (Sweden)

    Raimondo Gallo

    2013-09-01

    Full Text Available The first results of a new approach for implementing operational monitoring tool to control the performance of forest mechanisation chains are proposed and discussed. The solution is based on Global Navigation Satellite System (GNSS tools that are the core of a datalogging system that, in combination with a specific inference-engine, is able to analyse process times, work distances, forward speeds, vehicle tracking and number of working cycles in forest operations. As a consequence the operational monitoring control methods could provide an evaluation of the efficiency of the investigated forest operations. The study has monitored the performance of a tower yarder with crane and processor-head, during logging operations. The field surveys consisted on the installation of the GNSS device directly on the forest equipment for monitoring its movements. Simultaneously the field survey considered the integration of the GNSS information with a time study of work elements based on the continuous time methods supported by a time study board. Additionally, where possible, the onboard computer of the forest machine was also used in order to obtain additional information to be integrated to the GNSS data and the time study. All the recorded GNSS data integrated with the work elements study were thus post-processed through GIS analysis. The preliminary overview about the application of this approach on harvesting operations has permitted to assess a good feasibility of the use of GNSS in the relief of operative times in high mechanised forest chains. Results showed an easy and complete identification of the different operative cycles and elementary operations phases, with a maximum difference between the two methodologies of 10.32%. The use of GNSS installed on forest equipment, integrated with the inferenceengine and also with an interface for data communication or data storage, will permit an automatic or semi-automatic operational monitoring, improving

  2. Managed PACS operation with an automatic monitoring tool

    Science.gov (United States)

    Zhang, Jianguo; Han, Ruolin; Wu, Dongqing; Zhang, Xiaoyan; Zhuang, Jun; Feng, Jie; Wang, Mingpeng; Zhang, Guozhen; Wang, Cuanfu

    2002-05-01

    Huadong hospital in Shanghai with 800 beds provides health care services for inpatients and outpatients, as well as special senior and VIP patients. In order to move to digital imaging based radiology practice, and also provide better intra-hospital consultation services for senior and VIP patients, we started to implement PACS for hospital wide services from 1999, and also designed and developed an automatic monitoring system (AMS) to monitor and control PACS operation and dataflow to decrease the total cost of ownership for PACS operation. We installed the AMS on top of the Huadong Hospital PACS in the May of 2001. The installation was painless, did not interrupt the normal PACS operation, and took only one month. The PACS administrators with the AMS can now monitor and control the entire PACS operation in real time, and also track patient and image data flow automatically. These features make administrators take proper action even before user's complaint if any failure happened in any PACS component or process, they reduce the size of the management team, and decrease total cost of PACS ownership.

  3. International Cooperative Programme for Assessment and Monitoring of Acidification of Rivers and Lakes. Programme Manual

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, J.; Forsius, M.; Jeffries, D. [and others

    1996-12-31

    The International Cooperative Programme for Assessment of Acidification of Rivers and lakes (ICP Waters) was established in 1985 by the UN/ECE Executive Body for the Convention of Long-Range Transboundary Air Pollution. Achieving the programme objectives requires that both the temporally intensive and regionally extensive data are collected on a continuing basis. To guide the development and harmonization of the various national contributions, a manual was worked out. The present report is an expanded and consolidated revision of that manual. 33 refs., 3 tabs.

  4. Prototyping an Operational System with Multiple Sensors for Pasture Monitoring

    Directory of Open Access Journals (Sweden)

    Tim Wark

    2013-07-01

    Full Text Available Combining multiple proximal sensors within a wireless sensor network (WSN enhances our capacity to monitor vegetation, compared to using a single sensor or non-networked setup. Data from sensors with different spatial and temporal characteristics can provide complementary information. For example, point-based sensors such as multispectral sensors which monitor at high temporal frequency but, at a single point, can be complemented by array-based sensors such as digital cameras which have greater spatial resolution but may only gather data at infrequent intervals. In this article we describe the successful deployment of a prototype system for using multiple proximal sensors (multispectral sensors and digital cameras for monitoring pastures. We show that there are many technical issues involved in such a deployment, and we share insights relevant for other researchers who may consider using WSNs for an operational deployment for pasture monitoring under often difficult environmental conditions. Although the sensors and infrastructure are important, we found that other issues arise and that an end-to-end workflow is an essential part of effectively capturing, processing and managing the data from a WSN. Our deployment highlights the importance of testing and ongoing monitoring of the entire workflow to ensure the quality of data captured. We demonstrate that the combination of different sensors enhances our ability to identify sensor problems necessary to collect accurate data for pasture monitoring.

  5. Manual for habitat and vegetation surveillance and monitoring : temperate, mediterranean and desert biomes

    NARCIS (Netherlands)

    Bunce, R.G.H.; Bogers, M.M.B.; Roche, P.; Walczak, M.; Geijzendorffer, I.R.; Jongman, R.H.G.

    2011-01-01

    The primary objective of this Manual is to describe the methodology appropriate for coordinating information on habitats and vegetation in order to obtain statistically robust estimates of their extent and associated changes in biodiversity. Such detailed rules are necessary if surveillance, i.e., r

  6. Operational monitoring of turbidity in rivers: how satellites can contribute

    Science.gov (United States)

    Hucke, Dorothee; Hillebrand, Gudrun; Winterscheid, Axel; Kranz, Susanne; Baschek, Björn

    2016-10-01

    The applications of remote sensing in hydrology are diverse and offer significant benefits for water monitoring. Up to now, operational river monitoring and sediment management in Germany mainly rely on in-situ measurements and on results obtained from numerical modelling. Remote sensing by satellites has a great potential to supplement existing data with two-dimensional information on near-surface turbidity distributions at greater spatial scales than in-situ measurements can offer. Within the project WasMon-CT (WaterMonitoring-Chlorophyll/Turbidity), the Federal Institute of Hydrology (BfG) aims at the implementation of an operational monitoring of turbidity distributions based on satellite images (esp. Sentinel-2, Landsat7 and 8). Initially, selected federal inland and estuarine waterways will be addressed: Rhine, Elbe, Ems, Weser. WasMon-CT is funded within the German Copernicus activities. Within the project, a database of atmospherically corrected, geo-referenced turbidity data will be assembled. The collected corresponding meta-data will include aspects of satellite data as well as hydrological data, e.g. cloud cover and river run-off. Based on this catalogue of spatially linked meta-data, the satellite data will be selected by e.g. cloud cover or run-off. The permanently updated database will include past as well as recent satellite images. It is designed with a long-term perspective to optimize the existing in-situ measurement network, which will serve partly for calibration and partly as validation data set. The aim is to extend, but not to substitute, the existing frequent point measurements with spatially extensive, satellite-derived data from the near surface part of the water column. Here, turbidity is used as proxy for corresponding suspended sediment concentrations. For this, the relationship between turbidity and suspended sediment concentrations will be investigated. Products as e.g. longitudinal profiles or virtual measurement stations will be

  7. Airborne Transducer Integrity under Operational Environment for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Mohammad Saleh Salmanpour

    2016-12-01

    Full Text Available This paper investigates the robustness of permanently mounted transducers used in airborne structural health monitoring systems, when exposed to the operational environment. Typical airliners operate in a range of conditions, hence, structural health monitoring (SHM transducer robustness and integrity must be demonstrated for these environments. A set of extreme temperature, altitude and vibration environment test profiles are developed using the existing Radio Technical Commission for Aeronautics (RTCA/DO-160 test methods. Commercially available transducers and manufactured versions bonded to carbon fibre reinforced polymer (CFRP composite materials are tested. It was found that the DuraAct transducer is robust to environmental conditions tested, while the other transducer types degrade under the same conditions.

  8. Assessment model of dam operation risk based on monitoring data

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Although the dams produce remarkable social and economic benefits,the threat made by unsafe dams to the life and property of people who live in the lower river area is un-negligible.Based on the monitoring data which reflect the safety condition of dams,the risk degree concept is proposed and the analysis system and model for evaluating risk degree (rate) are established in this paper by combining the reliability theory and field monitoring data.The analysis method for risk degree is presented based on Bayesian approach.A five-grade risk degree system for dam operation risk and corresponding risk degree is put forward according to the safety condition of dams.The operation risks of four cascade dams on some river are analyzed by the model and approach presented here and the result is adopted by the owner.

  9. ATLAS trigger operations: Monitoring with ``Xmon'' rate prediction system

    Science.gov (United States)

    Aukerman, Andrew; Hong, Tae Min

    2017-01-01

    We present the operations and online monitoring with the ``Xmon'' rate prediction system for the trigger system at the ATLAS Experiment. A two-level trigger system reduces the LHC's bunch-crossing rate, 40 MHz at design capacity, to an average recording rate of about 1 kHz, while maintaining a high efficiency of selecting events of interest. The Xmon system uses the luminosity value to predict trigger rates that are, in turn, compared with incoming rates. The predictions rely on past runs to parameterize the luminosity dependency of the event rate for a trigger algorithm. Some examples are given to illustrate the performance of the tool during recent operations.

  10. Resource Conservation and Recovery Act (RCRA) new-employee training manual for the Operations Division RCRA personnel

    Energy Technology Data Exchange (ETDEWEB)

    Barkenbus, B.D.

    1987-03-01

    This manual has been prepared for the training of new employees who will work with RCRA hazardous waste management in the Operations Division. It will be taught by a person who is trained in hazardous waste regulations/procedures. It consists of nine modules. The topics of these modules are: RCRA Training, Hazardous Waste Regulations, Transportation Regulations, Hazardous Waste Management at ORNL, Chemical Hazards and Safety, Hazardous Waste Operations Training, Sampling of Hazardous Waste, Hazardous Waste Identification/Classification, and RCRA Contingency Plans and Emergency Procedures. The on-the-job training areas are identified in the modules. They are an integral part of training.

  11. Verification of operating software for cooperative monitoring applications

    Energy Technology Data Exchange (ETDEWEB)

    Tolk, K.M.; Rembold, R.K.

    1997-08-01

    Monitoring agencies often use computer based equipment to control instruments and to collect data at sites that are being monitored under international safeguards or other cooperative monitoring agreements. In order for this data to be used as an independent verification of data supplied by the host at the facility, the software used must be trusted by the monitoring agency. The monitoring party must be sure that the software has not be altered to give results that could lead to erroneous conclusions about nuclear materials inventories or other operating conditions at the site. The host might also want to verify that the software being used is the software that has been previously inspected in order to be assured that only data that is allowed under the agreement is being collected. A description of a method to provide this verification using keyed has functions and how the proposed method overcomes possible vulnerabilities in methods currently in use such as loading the software from trusted disks is presented. The use of public key data authentication for this purpose is also discussed.

  12. Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring

    Science.gov (United States)

    Pollock, Julie; Oliver, Brett; Brickner, Christopher

    2012-01-01

    A document discusses the utilization of embedded clocks inside of operating network data links as an auxiliary clock source to satisfy local oscillator monitoring requirements. Modem network interfaces, typically serial network links, often contain embedded clocking information of very tight precision to recover data from the link. This embedded clocking data can be utilized by the receiving device to monitor the local oscillator for tolerance to required specifications, often important in high-integrity fault-tolerant applications. A device can utilize a received embedded clock to determine if the local or the remote device is out of tolerance by using a single link. The local device can determine if it is failing, assuming a single fault model, with two or more active links. Network fabric components, containing many operational links, can potentially determine faulty remote or local devices in the presence of multiple faults. Two methods of implementation are described. In one method, a recovered clock can be directly used to monitor the local clock as a direct replacement of an external local oscillator. This scheme is consistent with a general clock monitoring function whereby clock sources are clocking two counters and compared over a fixed interval of time. In another method, overflow/underflow conditions can be used to detect clock relationships for monitoring. These network interfaces often provide clock compensation circuitry to allow data to be transferred from the received (network) clock domain to the internal clock domain. This circuit could be modified to detect overflow/underflow conditions of the buffering required and report a fast or slow receive clock, respectively.

  13. Sensors and OBIA synergy for operational monitoring of surface water

    Science.gov (United States)

    Masson, Eric; Thenard, Lucas

    2010-05-01

    This contribution will focus on combining Object Based Image Analysis (i.e. OBIA with e-Cognition 8) and recent sensors (i.e. Spot 5 XS, Pan and ALOS Prism, Avnir2, Palsar) to address the technical feasibility for an operational monitoring of surface water. Three cases of river meandering (India), flood mapping (Nepal) and dam's seasonal water level monitoring (Morocco) using recent sensors will present various application of surface water monitoring. The operational aspect will be demonstrated either by sensor properties (i.e. spatial resolution and bandwidth), data acquisition properties (i.e. multi sensor, return period and near real-time acquisition) but also with OBIA algorithms (i.e. fusion of multi sensors / multi resolution data and batch processes). In the first case of river meandering (India) we will address multi sensor and multi date satellite acquisition to monitor the river bed mobility within a floodplain using an ALOS dataset. It will demonstrate the possibility of an operational monitoring system that helps the geomorphologist in the analysis of fluvial dynamic and sediment budget for high energy rivers. In the second case of flood mapping (Nepal) we will address near real time Palsar data acquisition at high spatial resolution to monitor and to map a flood extension. This ALOS sensor takes benefit both from SAR and L band properties (i.e. atmospheric transparency, day/night acquisition, low sensibility to surface wind). It's a real achievement compared to optical imagery or even other high resolution SAR properties (i.e. acquisition swath, bandwidth and data price). These advantages meet the operational needs set by crisis management of hydrological disasters but also for the implementation of flood risk management plans. The last case of dam surface water monitoring (Morocco) will address an important issue of water resource management in countries affected by water scarcity. In such countries water users have to cope with over exploitation

  14. Monitoring data transfer latency in CMS computing operations

    CERN Document Server

    Bonacorsi, D; Magini, N; Sartirana, A; Taze, M; Wildish, T

    2015-01-01

    During the first LHC run, the CMS experiment collected tens of Petabytes of collision and simulated data, which need to be distributed among dozens of computing centres with low latency in order to make efficient use of the resources. While the desired level of throughput has been successfully achieved, it is still common to observe transfer workflows that cannot reach full completion in a timely manner due to a small fraction of stuck files which require operator intervention.For this reason, in 2012 the CMS transfer management system, PhEDEx, was instrumented with a monitoring system to measure file transfer latencies, and to predict the completion time for the transfer of a data set. The operators can detect abnormal patterns in transfer latencies while the transfer is still in progress, and monitor the long-term performance of the transfer infrastructure to plan the data placement strategy.Based on the data collected for one year with the latency monitoring system, we present a study on the different fact...

  15. Operational Surface Water Detection and Monitoring Using Radarsat 2

    Directory of Open Access Journals (Sweden)

    Sandra Bolanos

    2016-03-01

    Full Text Available Traditional on-site methods for mapping and monitoring surface water extent are prohibitively expensive at a national scale within Canada. Despite successful cost-sharing programs between the provinces and the federal government, an extensive number of water features within the country remain unmonitored. Particularly difficult to monitor are the potholes in the Canadian Prairie region, most of which are ephemeral in nature and represent a discontinuous flow that influences water pathways, runoff response, flooding and local weather. Radarsat-2 and the Radarsat Constellation Mission (RCM offer unique capabilities to map the extent of water bodies at a national scale, including unmonitored sites, and leverage the current infrastructure of the Meteorological Service of Canada to monitor water information in remote regions. An analysis of the technical requirements of the Radarsat-2 beam mode, polarization and resolution is presented. A threshold-based procedure to map locations of non-vegetated water bodies after the ice break-up is used and complemented with a texture-based indicator to capture the most homogeneous water areas and automatically delineate their extents. Some strategies to cope with the radiometric artifacts of noise inherent to Synthetic Aperture Radar (SAR images are also discussed. Our results show that Radarsat-2 Fine mode can capture 88% of the total water area in a fully automated way. This will greatly improve current operational procedures for surface water monitoring information and impact a number of applications including weather forecasting, hydrological modeling, and drought/flood predictions.

  16. Westinghouse Hanford Company operational environmental monitoring annual report, CY 1992

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, J.W.; Johnson, A.R.; McKinney, S.M.; Perkins, C.J.

    1993-07-01

    This document presents the results of the Westinghouse Hanford Company near-facility operational environmental monitoring for 1992 in the 100, 200/600, and 300/400 Areas of the Hanford Site, in south-central Washington State in 1992. Surveillance activities included sampling and analyses of ambient air, surface water, groundwater, sediments, soil, and biota. Also, external radiation measurements and radiological surveys were taken at waste disposal sites, radiologically controlled areas, and roads. These activities were conducted to assess and to control the impacts of nuclear facilities and waste sites on the workers and the local environment. Additionally, diffuse sources were monitored to determine compliance with Federal, State, and/or local regulations. In general, although impacts from nuclear facilities are still seen on the Hanford Site and are slightly elevated when compared to offsite, these impacts are less than in previous years.

  17. DUVAS (derivative uv-absorption spectrometer): instrument description and operating manual

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, A.R.; Dougherty, J.M.; Metcalfe, C.E.

    1980-11-01

    DUVAS is a real-time, field-portable spectrometer capable of monitoring a variety of aromatic organic vapors and inorganic gases at sub-ppM concentrations. The instrument is a prototype, microcomputer-controlled, derivative ultraviolet (UV) absorption spectrometer (DUVAS) developed primarily for area monitoring at coal conversion facilities, although other important occupational and environmental monitoring applications for compounds such as SO/sub 2/, NO/sub x/, NH/sub 3/, and HCHO are also being pursued.

  18. CCSDS Spacecraft Monitor and Control Mission Operations Interoperability Prototype

    Science.gov (United States)

    Lucord, Steve; Martinez, Lindolfo

    2009-01-01

    We are entering a new era in space exploration. Reduced operating budgets require innovative solutions to leverage existing systems to implement the capabilities of future missions. Custom solutions to fulfill mission objectives are no longer viable. Can NASA adopt international standards to reduce costs and increase interoperability with other space agencies? Can legacy systems be leveraged in a service oriented architecture (SOA) to further reduce operations costs? The Operations Technology Facility (OTF) at the Johnson Space Center (JSC) is collaborating with Deutsches Zentrum fur Luft- und Raumfahrt (DLR) to answer these very questions. The Mission Operations and Information Management Services Area (MOIMS) Spacecraft Monitor and Control (SM&C) Working Group within the Consultative Committee for Space Data Systems (CCSDS) is developing the Mission Operations standards to address this problem space. The set of proposed standards presents a service oriented architecture to increase the level of interoperability among space agencies. The OTF and DLR are developing independent implementations of the standards as part of an interoperability prototype. This prototype will address three key components: validation of the SM&C Mission Operations protocol, exploration of the Object Management Group (OMG) Data Distribution Service (DDS), and the incorporation of legacy systems in a SOA. The OTF will implement the service providers described in the SM&C Mission Operation standards to create a portal for interaction with a spacecraft simulator. DLR will implement the service consumers to perform the monitor and control of the spacecraft. The specifications insulate the applications from the underlying transport layer. We will gain experience with a DDS transport layer as we delegate responsibility to the middleware and explore transport bridges to connect disparate middleware products. A SOA facilitates the reuse of software components. The prototype will leverage the

  19. Operational climate monitoring from space: the EUMETSAT satellite application facility on climate monitoring (CM-SAF

    Directory of Open Access Journals (Sweden)

    J. Schulz

    2008-05-01

    Full Text Available The Satellite Application Facility on Climate Monitoring (CM-SAF aims at the provision of satellite-derived geophysical parameter data sets suitable for climate monitoring. CM-SAF provides climatologies for Essential Climate Variables (ECV, as required by the Global Climate Observing System implementation plan in support of the UNFCCC. Several cloud parameters, surface albedo, radiation fluxes at the top of the atmosphere and at the surface as well as atmospheric temperature and humidity products form a sound basis for climate monitoring of the atmosphere. The products are categorized in monitoring data sets obtained in near real time and data sets based on carefully intercalibrated radiances. The CM-SAF products are derived from several instruments on-board operational satellites in geostationary and polar orbit, i.e., the Meteosat and NOAA satellites, respectively. The existing data sets will be continued using data from the instruments on-board the new EUMETSAT Meteorological Operational satellite (MetOP. The products have mostly been validated against several ground-based data sets both in situ and remotely sensed. The accomplished accuracy for products derived in near real time is sufficient to monitor variability on diurnal and seasonal scales. Products based on intercalibrated radiance data can also be used for climate variability analysis up to inter-annual scale. A central goal of the recently started Continuous Development and Operations Phase of the CM-SAF (2007–2012 is to further improve all CM-SAF data sets to a quality level that allows for studies of inter-annual variability.

  20. Manual of methods for use in the South African Marine Pollution Monitoring Programme

    CSIR Research Space (South Africa)

    Watling, RJ

    1981-07-01

    Full Text Available Methods used in the South African Marine Pollution Monitoring Programme for the analysis of toxic metals, nutrients, oxygen absorbed, chlorophyll, pesticides and bacteria are described. Sample types include biological material, sediments, estuarine...

  1. In Vivo Monitoring Program Manual, PNL-MA-574, Rev 5.1

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, Timothy P.

    2011-09-12

    The following sections provide an overview of the administration for the In Vivo Monitoring Program (IVMP) for Hanford. This includes the organizational structure and program responsibilities; coordination of in vivo measurements; scheduling measurements; performing measurements; reporting results; and quality assurance.

  2. Operating manual for the High Flux Isotope Reactor. Volume I. Description of the facility

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    This volume contains a comprehensive description of the High Flux Isotope Reactor Facility. Its primary purpose is to supplement the detailed operating procedures, providing the reactor operators with background information on the various HFIR systems. The detailed operating procdures are presented in another report.

  3. Comparison of automated and manual follicle monitoring in an unrestricted population of 100 women undergoing controlled ovarian stimulation for IVF.

    Science.gov (United States)

    Ata, Baris; Seyhan, Ayse; Reinblatt, Shauna Leigh; Shalom-Paz, Einat; Krishnamurthy, Srinivasan; Tan, Seang Lin

    2011-01-01

    Ovarian response to gonadotrophin stimulation is monitored with serial ultrasound (US) examinations. Sonography-based Automated Volume Count (SonoAVC) is a relatively new three-dimensional (3D) US technology, which automatically generates a set of measurements including the mean follicular diameter (MFD) and a volume-based diameter (d(V)) for each follicle in the ovaries. The present study aimed to assess the applicability and reproducibility of this automated follicle measurement method in an IVF programme. For this prospective method comparison study, 100 women undergoing US monitoring of a controlled ovarian stimulation cycle were recruited. Each follicle was manually measured by taking the mean of maximal diameters on three orthogonal planes with two-dimensional (2D) US. A 3D volume of each ovary was then captured. The ovarian volumes were later analysed using SonoAVC. The agreement between the two methods for the numbers of follicles and the size of the leading follicle was assessed with the Bland-Altman method. The reproducibility of SonoAVC measurements was assessed with the intraclass correlation coefficient (ICC). Both SonoAVC-generated MFD and d(V)-based follicle counts, as well as the leading follicle diameter, had good agreement with conventional 2D US measurements. SonoAVC measurements had very good reproducibility, with ICC ≥0.8 for most evaluations. Automated follicle monitoring with SonoAVC can replace or be used interchangeably with conventional 2D measurements. Automated follicle monitoring can save time, provide a method of quality control and create opportunities for developing HCG criteria based on follicular volume or for monitoring patients from a distance.

  4. MONITORING DIAGNOSTIC INDICATORS DURING OPERATION OF A PRINT MACHIN

    Directory of Open Access Journals (Sweden)

    Jozef Dobránsky

    2015-11-01

    Full Text Available This article deals with monitoring diagnostic indicators during the operation of a machine used for production of packing materials with a print. It analyses low-frequency vibrations measured in individual spherical roller bearings in eight print positions. The rollers in these positions have a different pressure based on positioning these rollers in relation to the central roller. As a result, the article also deals with a correlation of pressure and level of measured low-frequency vibrations. The speed of the print machine (the speed of a line in meters per minute is a very important variable during its operation, this is why it is important to verify the values of vibrations in various speeds of the line, what can lead to revelation of one or more resonance areas. Moreover, it examines vibrations of the central roller drive and measurement of backlash of transmission cogs of this drive. Based on performed analyses recommendations for an operator of the machine have been conceived.

  5. Structural Health Monitoring under Nonlinear Environmental or Operational Influences

    Directory of Open Access Journals (Sweden)

    Jyrki Kullaa

    2014-01-01

    Full Text Available Vibration-based structural health monitoring is based on detecting changes in the dynamic characteristics of the structure. It is well known that environmental or operational variations can also have an influence on the vibration properties. If these effects are not taken into account, they can result in false indications of damage. If the environmental or operational variations cause nonlinear effects, they can be compensated using a Gaussian mixture model (GMM without the measurement of the underlying variables. The number of Gaussian components can also be estimated. For the local linear components, minimum mean square error (MMSE estimation is applied to eliminate the environmental or operational influences. Damage is detected from the residuals after applying principal component analysis (PCA. Control charts are used for novelty detection. The proposed approach is validated using simulated data and the identified lowest natural frequencies of the Z24 Bridge under temperature variation. Nonlinear models are most effective if the data dimensionality is low. On the other hand, linear models often outperform nonlinear models for high-dimensional data.

  6. Integrating real-time and manual monitored data to predict hillslope soil moisture dynamics with high spatio-temporal resolution using linear and non-linear models

    Science.gov (United States)

    Zhu, Qing; Zhou, Zhiwen; Duncan, Emily W.; Lv, Ligang; Liao, Kaihua; Feng, Huihui

    2017-02-01

    Spatio-temporal variability of soil moisture (θ) is a challenge that remains to be better understood. A trade-off exists between spatial coverage and temporal resolution when using the manual and real-time θ monitoring methods. This restricted the comprehensive and intensive examination of θ dynamics. In this study, we integrated the manual and real-time monitored data to depict the hillslope θ dynamics with good spatial coverage and temporal resolution. Linear (stepwise multiple linear regression-SMLR) and non-linear (support vector machines-SVM) models were used to predict θ at 39 manual sites (collected 1-2 times per month) with θ collected at three real-time monitoring sites (collected every 5 mins). By comparing the accuracies of SMLR and SVM for each depth and manual site, an optimal prediction model was then determined at this depth of this site. Results showed that θ at the 39 manual sites can be reliably predicted (root mean square errors model. The subsurface flow dynamics was an important factor that determined whether the relationship was linear or non-linear. Depth to bedrock, elevation, topographic wetness index, profile curvature, and θ temporal stability influenced the selection of prediction model since they were related to the subsurface soil water distribution and movement. Using this approach, hillslope θ spatial distributions at un-sampled times and dates can be predicted. Missing information of hillslope θ dynamics can be acquired successfully.

  7. Submicron particle monitoring of paving and related road construction operations.

    Science.gov (United States)

    Freund, Alice; Zuckerman, Norman; Baum, Lisa; Milek, Debra

    2012-01-01

    This study identified activities and sources that contribute to ultrafine and other submicron particle exposure that could trigger respiratory symptoms in highway repair workers. Submicron particle monitoring was conducted for paving, milling, and pothole repair operations in a major metropolitan area where several highway repair workers were identified as symptomatic for respiratory illness following exposures at the 2001 World Trade Center disaster site. Exposure assessments were conducted for eight trades involved in road construction using a TSI P-Trak portable condensation particle counter. Direct readings near the workers' breathing zones and observations of activities and potential sources were logged on 7 days on 27 workers using four different models of pavers and two types of millers. Average worker exposure levels ranged from 2 to 3 times background during paving and from 1 to 4 times background during milling. During asphalt paving, average personal exposures to submicron particulates were 25,000-60,000, 28,000-70,000, and 23,000-37,000 particles/ cm(3) for paver operators, screed operators, and rakers, respectively. Average personal exposures during milling were 19,000-111,000, 28,000-81,000, and 19,000 particles/cm(3) for the large miller operators, miller screed operators, and raker, respectively. Personal peak exposures were measured up to 467,000 and 455,000 particles/cm(3) in paving and milling, respectively. Several sources of submicron particles were identified. These included the diesel and electric fired screed heaters; engine exhaust from diesel powered construction vehicles passing by or idling; raking, dumping, and paving of asphalt; exhaust from the hotbox heater; pavement dust or fumes from milling operations, especially when the large miller started and stopped; and secondhand cigarette smoke. To reduce the potential for health effects in workers, over 40 recommendations were made to control exposures, including improved maintenance of

  8. Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, J.B.

    1996-05-21

    The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce maintenance costs. Ten prototype units have been built and tested. This report describes the design of the new NIM and the testing that took place to verify its acceptability.

  9. Best Management Practices (BMP) Monitoring Manual Field Guide: Implementation and Effectiveness for Protection of Water Resources

    Science.gov (United States)

    David Welsch; Roger Ryder; Tim Post

    2006-01-01

    The specific purpose of the BMP protocol is to create an economical, standardized, and repeatable BMP monitoring process that is completely automated, from data gathering through report generation, in order to provide measured data, ease of use, and compatibility with State BMP programs.The protocol was developed to meet the following needs:? Document the use and...

  10. Water Quality Monitoring: An Environmental Studies Unit for Biology 20/30. Student Manual.

    Science.gov (United States)

    Alberta Environment, Edmonton. Environmental Education Resources Branch.

    The objective of this environmental studies unit is to establish a water quality monitoring project for high school students in Alberta while simultaneously providing a unit which meets the objectives of the Biology 20 program (and which may also be used in Biology 10 and 30). Through this project, students assist in the collection,…

  11. Damage detection and health monitoring of operational structures

    Energy Technology Data Exchange (ETDEWEB)

    James, G.; Mayes, R.; Carne, T.; Reese, G.

    1994-09-01

    Initial damage detection/health monitoring experiments have been performed on three different operational structures: a fracture critical bridge, a composite wind turbine blade, and an aging aircraft. An induced damage test was performed on the Rio Grande/I40 bridge before its demolition. The composite wind turbine test was fatgued to failure with periodic modal testing performed throughout the testing. The front fuselage of a DC-9 aircraft was used as the testbed for an induced damage test. These tests have yielded important insights into techniques for experimental damage detection on real structures. Additionally, the data are currently being used with current damage detection algorithms to further develop the numerical technology. State of the art testing technologies such as, high density modal testing, scanning laser vibrometry and natural excitation testing have also been utilized for these tests.

  12. Operational Performance Analysis of Passive Acoustic Monitoring for Killer Whales

    Energy Technology Data Exchange (ETDEWEB)

    Matzner, Shari; Fu, Tao; Ren, Huiying; Deng, Zhiqun; Sun, Yannan; Carlson, Thomas J.

    2011-09-30

    For the planned tidal turbine site in Puget Sound, WA, the main concern is to protect Southern Resident Killer Whales (SRKW) due to their Endangered Species Act status. A passive acoustic monitoring system is proposed because the whales emit vocalizations that can be detected by a passive system. The algorithm for detection is implemented in two stages. The first stage is an energy detector designed to detect candidate signals. The second stage is a spectral classifier that is designed to reduce false alarms. The evaluation presented here of the detection algorithm incorporates behavioral models of the species of interest, environmental models of noise levels and potential false alarm sources to provide a realistic characterization of expected operational performance.

  13. 33 CFR 157.226 - Dedicated Clean Ballast Tanks Operations Manual: Procedures to be followed.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Dedicated Clean Ballast Tanks... ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels Dedicated Clean Ballast Tanks Operations § 157.226 Dedicated Clean Ballast Tanks Operations...

  14. Depth of Blanket. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Arasmith, E. E.

    The determination of the thickness of a sludge blanket in primary and secondary clarifiers and in gravity thickness is important in making operational control decisions. Knowing the thickness and concentration will allow the operator to determine sludge volume and detention time. Designed for individuals who have completed National Pollutant…

  15. 40 CFR 63.2164 - If I monitor brew ethanol, what are my monitoring installation, operation, and maintenance...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true If I monitor brew ethanol, what are my... monitor brew ethanol, what are my monitoring installation, operation, and maintenance requirements? (a... considered by us to be generally optimum. Use the brew-to-exhaust correlation equation established under §...

  16. Long Length Contaminated Equipment Retrieval System Receiver Trailer and Transport Trailer Operations and Maintenance Manual

    Energy Technology Data Exchange (ETDEWEB)

    DALE, R.N.

    2000-05-01

    A system to accommodate the removal of long-length contaminated equipment (LLCE) from Hanford underground radioactive waste storage tanks was designed, procured, and demonstrated, via a project activity during the 1990s. The system is the Long Length Contaminated Equipment Removal System (LLCERS). LLCERS will be maintained and operated by Tank Farms Engineering and Operations organizations and other varied projects having a need for the system. The responsibility for the operation and maintenance of the LLCERS Receiver Trailer (RT) and Transport Trailer (TT) resides with the RPP Characterization Project Operations organization. The purpose of this document is to provide vendor supplied operating and maintenance (O & M) information for the RT and TT in a readily retrievable form. This information is provided this way instead of in a vendor information (VI) file to maintain configuration control of the operations baseline as described in RPP-6085, ''Configuration Management Plan for Long Length Contaminated Equipment Receiver and Transport Trailers''. Additional Operations Baseline documents are identified in RPP-6085.

  17. Intra—Operative Facial Nerve Monitoring in Acoustic Neurinoma Surgery

    Institute of Scientific and Technical Information of China (English)

    YANGZhengming; ZHANGZhifeng; 等

    2002-01-01

    Objective To determine the method and significance of facial nerve preservation during acoustic neurinoma surgery by intra-operative facial nerve monitoring(IFNM).Methods 62 patients were randomly assigned to the IFNM or the control group.Facial nerve function(FNF)was assessed by a modified House-Brackmann grading(HB)before the operation,10 days and every two months after surgery and com,pared between the two groups. Results Ten days after surgery,26/32 patients in the IFNM group and 15/30 patients in the control group had FNF HB grade,Ⅰ-Ⅲ;FNF HB gradeⅣ-Ⅴ was prestent in 6/32 in the IFNM group and 15/30 in the control group.During follow-up,29/32 patients in the IFNM group and 20/20 patients in the control group had FNF HB gradeⅠ-Ⅲ;FNF HB gradeⅣ-Ⅴ was present in 3/32 in the IFNM group and 10/30 in the control group.All differnces were statistcally significant.Conclusion IFNM significantly improved anatomic and functional facial nerve preservation as well as the quality of life.

  18. 78 FR 73112 - Monitoring System Conditions-Transmission Operations Reliability Standards; Interconnection...

    Science.gov (United States)

    2013-12-05

    ..., performance, and maintenance of real-time monitoring and analysis capabilities for reliability coordinators... Reliability Standards; Interconnection Reliability Operations and Coordination Reliability Standards AGENCY... Transmission Operations and Interconnection Reliability Operations and Coordination Reliability Standards...

  19. High quality and large-scale manually operated monolayer graphene pasters

    Science.gov (United States)

    Wei, Yuke; Zhang, Yan; Liu, Zhenghao; Wang, Yue; Ke, Fen; Meng, Jie; Guo, Yanjun; Ma, Ping; Feng, Qingrong; Gan, Zizhao

    2014-07-01

    Graphene is a well-known material with various potential applications. Here we report the manufacture of high-quality and large-scale monolayer graphene pasters via polyvinyl butyral (PVB). These pasters have good self-supporting properties and overcome the drawback of weak mechanical strength of PMMA. Manual manipulations to monolayer graphene become realizable via graphene pasters. Graphene pasters can be quickly diverted onto any substrate with sufficient contact and greatly minimize the challenges in graphene transfer, measurements, and other applications. The improved transfer process via graphene pasters protects the integrity of monolayer graphene and introduces few cracks or tears into graphene. Large-scale monolayer graphene films diverted onto SiO2/Si by using graphene pasters maintain low resistivity and low Dirac point, while also exhibiting a higher magnetoresistance than traditional results. High magnetoresistance up to 600% and signs of saturation at high magnetic fields can be seen. Obvious negative magnetoresistance at low magnetic fields due to weak localization also can be observed. Graphene pasters can be used in many different domains and will promote future studies and applications of graphene.

  20. Operating and maintenance manual for the HFIR production model homogeneity scanner

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, J.W.; Shipp, R.L.; Sliski, T.F.; Longaker, W.H.; Klindt, K.K.

    1984-12-01

    The fuel material in a HFIR fuel is U/sub 3/O/sub 8/ dispersed in aluminum, resembling an airfoil in cross section. To ensure uniform generation of heat within the plate, all plates must be tested (nondestructively) to determine that the U/sub 3/O/sub 8/ content is within specified limits. The HFIR homogeneity scanner developed for this purpose is a density/thickness gauge that bombards a plate with a highly collimated, 0.062-in.-diam beam of x rays and detects those transmitted through the plate. Variations in the transmitted x rays due to absorption in the fuel plate are a measure of fuel denisty. In addition to the fuel plates for HFIR, fuel plates for several other reactors, such as the Oak Ridge Research Reactor (ORR) are also checked by the homogeneity scanner by using other sets of standards. All of the other reactors have a uniform cross section. This manual describes procedures for its electronic components.

  1. 33 CFR 157.138 - Crude Oil Washing Operations and Equipment Manual.

    Science.gov (United States)

    2010-07-01

    ... stripping suction device. (iv) Number and location of COW machines operating simultaneously in each cargo... crude oil. (13) The procedure for draining and stripping the pumps and piping of the COW system,...

  2. Operation and maintenance manual for the common video end effector system (CVEE) system 6260

    Energy Technology Data Exchange (ETDEWEB)

    Pardini, A.F., Westinghouse Hanford

    1996-07-24

    This document defines the requirements for the operation,maintenance, and storage of the Common Video End Effector System (CVEE) used with the video end effectors as part of the Light Duty Utility Arm (LDUA) system.

  3. Safety and Mission Assurance (SMA) Automated Task Order Management System (ATOMS) Operation Manual

    Science.gov (United States)

    Wallace, Shawn; Fikes, Lou A.

    2016-01-01

    This document describes operational aspects of the ATOMS system. The information provided is limited to the functionality provided by ATOMS and does not include information provided in the contractor's proprietary financial and task management system.

  4. Manual for monitoring/inspection of integrity of sub sea flexible line - risk based inspection; Manual para monitoramento/inspecao de integridade de linha flexivel submarina - inspecao baseada em risco

    Energy Technology Data Exchange (ETDEWEB)

    Simoes Filho, Salvador; Souza, Luiz Antonio Lobianco e [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Tecnologia Submarina]. E-mails: salvador@cenpes.petrobras.com.br; lobianco@cenpes.petrobras.com.br; Monteiro Filho, Ivan de Andrade [PETROBRAS, Rio de Janeiro, RJ (Brazil). Exploracao e Producao. Unidade de Servicos - Submarino). E-mail: ivanmonteiro@petrobras.com.br

    2003-12-01

    This is the description of the 'Manual for Monitoring/Inspection of Integrity of Subsea Flexible Line - Risk Based Inspection - IBR' , developed by professionals at PETROBRAS (CENPES, E and P-CORP, E and P-SSE and UN-RIO). It presents the methodology for the management of integrity of flexible lines systems used in sub sea environment. The adopted philosophy was that of 'PGR - Risk Management Program' using risk based inspection. The emphasis on risk is adopted for the developed, critical analysis and review of the Monitoring/Inspection Program. (author)

  5. Instruction manual for the ILAE 2017 operational classification of seizure types.

    Science.gov (United States)

    Fisher, Robert S; Cross, J Helen; D'Souza, Carol; French, Jacqueline A; Haut, Sheryl R; Higurashi, Norimichi; Hirsch, Edouard; Jansen, Floor E; Lagae, Lieven; Moshé, Solomon L; Peltola, Jukka; Roulet Perez, Eliane; Scheffer, Ingrid E; Schulze-Bonhage, Andreas; Somerville, Ernest; Sperling, Michael; Yacubian, Elza Márcia; Zuberi, Sameer M

    2017-04-01

    This companion paper to the introduction of the International League Against Epilepsy (ILAE) 2017 classification of seizure types provides guidance on how to employ the classification. Illustration of the classification is enacted by tables, a glossary of relevant terms, mapping of old to new terms, suggested abbreviations, and examples. Basic and extended versions of the classification are available, depending on the desired degree of detail. Key signs and symptoms of seizures (semiology) are used as a basis for categories of seizures that are focal or generalized from onset or with unknown onset. Any focal seizure can further be optionally characterized by whether awareness is retained or impaired. Impaired awareness during any segment of the seizure renders it a focal impaired awareness seizure. Focal seizures are further optionally characterized by motor onset signs and symptoms: atonic, automatisms, clonic, epileptic spasms, or hyperkinetic, myoclonic, or tonic activity. Nonmotor-onset seizures can manifest as autonomic, behavior arrest, cognitive, emotional, or sensory dysfunction. The earliest prominent manifestation defines the seizure type, which might then progress to other signs and symptoms. Focal seizures can become bilateral tonic-clonic. Generalized seizures engage bilateral networks from onset. Generalized motor seizure characteristics comprise atonic, clonic, epileptic spasms, myoclonic, myoclonic-atonic, myoclonic-tonic-clonic, tonic, or tonic-clonic. Nonmotor (absence) seizures are typical or atypical, or seizures that present prominent myoclonic activity or eyelid myoclonia. Seizures of unknown onset may have features that can still be classified as motor, nonmotor, tonic-clonic, epileptic spasms, or behavior arrest. This "users' manual" for the ILAE 2017 seizure classification will assist the adoption of the new system. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  6. Operations manual for the patient assist device. [to handle electrical appliances

    Science.gov (United States)

    Schrader, M. A.

    1973-01-01

    Quadriplegic patients and multiple amputee patients are almost totally dependent on nursing personnel for any activities or interests in which they participate. A patient assist device is reported which provides patient control over electrical devices in his environment. The patient operates three switches to acquire control over a desired electrical appliance. The type switches employed are chosen to conform to patient capabilities, even when such capabilities are as limited as eye or head movements. The switch operations are sensed and converted into command signals by the patient assist device to control ten electrical appliances simulataneously and independently.

  7. Solar Powered Aircraft, Photovoltaic Array/Battery System Tabletop Demonstration: Design and Operation Manual

    Science.gov (United States)

    Colozza, Anthony J.; Scheiman, David A.; Bailey, Sheila (Technical Monitor)

    2000-01-01

    A system was constructed to demonstrate the power system operation of a solar powered aircraft. The system consists of a photovoltaic (PV) array, a charge controller, a battery, an electric motor and propeller. The system collects energy from the PV array and either utilizes this energy to operate an electric motor or stores it in a rechargeable battery for future use. The system has a control panel which displays the output of the array and battery as well as the total current going to the electric motor. The control panel also has a means for adjusting the output to the motor to control its speed. The entire system is regulated around 12 VDC.

  8. Comparison of Operator Aided Optimization with Iterative Manual Optimization in a Simulated Tactical Decision Aiding Task.

    Science.gov (United States)

    1980-07-01

    4 5 ,/, . LEG - - .... .... . ...................... . "S ’= .. 0 fUNCION EVALUAIONS A 52 i TILITY 50 go BLEST UTILITY TO DATE 73.73 The operator...NS S.. 250 - " \\ M..= . BES UTIIT TO U = 37 -122- l .- - ’. ’-,-,,--/-- ’ I / I5 -- S. *1 3 4 FUNCION (3) BES ’ ) I -.B= .0ś FUCINEV/ALL T IONS 1

  9. Installation and operation manual on sea level gauge (Model: NIO_Ghana_2004)

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A; Pereira, A; VijayKumar, K.; Prabhudesai, S.; Methar, A; Dias, M.

    NIO sea level gauge is a pressure-based gauge that operates on 12 volts battery. The pressure-sensing element used in this gauge is a piezo-resistive programmable semiconductor transducer that provides pressure samples in RS-485 format...

  10. Capillary Suction Time. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Wooley, John F.

    Capillary suction time is time required for the liquid phase of a treated sludge to travel through 1 centimeter of media (blotter or filter paper). Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module provides waste water treatment plant operators with…

  11. 33 CFR 150.15 - What must the operations manual include?

    Science.gov (United States)

    2010-07-01

    ... propulsion and steering on standby. (6) The start up and completion of pumping. (7) Emergency shutdown. (8.... (g) The size, type, number, and simultaneous operations of tankers that the port can handle. (h... deepwater port: (i) Type of radar; (ii) Characteristics of the radar; (iii) Antenna location; (iv...

  12. Operating system for a real-time multiprocessor propulsion system simulator. User's manual

    Science.gov (United States)

    Cole, G. L.

    1985-01-01

    The NASA Lewis Research Center is developing and evaluating experimental hardware and software systems to help meet future needs for real-time, high-fidelity simulations of air-breathing propulsion systems. Specifically, the real-time multiprocessor simulator project focuses on the use of multiple microprocessors to achieve the required computing speed and accuracy at relatively low cost. Operating systems for such hardware configurations are generally not available. A real time multiprocessor operating system (RTMPOS) that supports a variety of multiprocessor configurations was developed at Lewis. With some modification, RTMPOS can also support various microprocessors. RTMPOS, by means of menus and prompts, provides the user with a versatile, user-friendly environment for interactively loading, running, and obtaining results from a multiprocessor-based simulator. The menu functions are described and an example simulation session is included to demonstrate the steps required to go from the simulation loading phase to the execution phase.

  13. Operation and maintenance manual for the high resolution stereoscopic video camera system (HRSVS) system 6230

    Energy Technology Data Exchange (ETDEWEB)

    Pardini, A.F., Westinghouse Hanford

    1996-07-16

    The High Resolution Stereoscopic Video Cameral System (HRSVS),system 6230, is a stereoscopic camera system that will be used as an end effector on the LDUA to perform surveillance and inspection activities within Hanford waste tanks. It is attached to the LDUA by means of a Tool Interface Plate (TIP), which provides a feed through for all electrical and pneumatic utilities needed by the end effector to operate.

  14. Mediterranean monitoring and forecasting operational system for Copernicus Marine Service

    Science.gov (United States)

    Coppini, Giovanni; Drudi, Massimiliano; Korres, Gerasimos; Fratianni, Claudia; Salon, Stefano; Cossarini, Gianpiero; Clementi, Emanuela; Zacharioudaki, Anna; Grandi, Alessandro; Delrosso, Damiano; Pistoia, Jenny; Solidoro, Cosimo; Pinardi, Nadia; Lecci, Rita; Agostini, Paola; Cretì, Sergio; Turrisi, Giuseppe; Palermo, Francesco; Konstantinidou, Anna; Storto, Andrea; Simoncelli, Simona; Di Pietro, Pier Luigi; Masina, Simona; Ciliberti, Stefania Angela; Ravdas, Michalis; Mancini, Marco; Aloisio, Giovanni; Fiore, Sandro; Buonocore, Mauro

    2016-04-01

    The MEDiterranean Monitoring and Forecasting Center (Med-MFC) is part of the Copernicus Marine Environment Monitoring Service (CMEMS, http://marine.copernicus.eu/), provided on an operational mode by Mercator Ocean in agreement with the European Commission. Specifically, Med MFC system provides regular and systematic information about the physical state of the ocean and marine ecosystems for the Mediterranean Sea. The Med-MFC service started in May 2015 from the pre-operational system developed during the MyOcean projects, consolidating the understanding of regional Mediterranean Sea dynamics, from currents to biogeochemistry to waves, interfacing with local data collection networks and guaranteeing an efficient link with other Centers in Copernicus network. The Med-MFC products include analyses, 10 days forecasts and reanalysis, describing currents, temperature, salinity, sea level and pelagic biogeochemistry. Waves products will be available in MED-MFC version in 2017. The consortium, composed of INGV (Italy), HCMR (Greece) and OGS (Italy) and coordinated by the Euro-Mediterranean Centre on Climate Change (CMCC, Italy), performs advanced R&D activities and manages the service delivery. The Med-MFC infrastructure consists of 3 Production Units (PU), for Physics, Biogechemistry and Waves, a unique Dissemination Unit (DU) and Archiving Unit (AU) and Backup Units (BU) for all principal components, guaranteeing a resilient configuration of the service and providing and efficient and robust solution for the maintenance of the service and delivery. The Med-MFC includes also an evolution plan, both in terms of research and operational activities, oriented to increase the spatial resolution of products, to start wave products dissemination, to increase temporal extent of the reanalysis products and improving ocean physical modeling for delivering new products. The scientific activities carried out in 2015 concerned some improvements in the physical, biogeochemical and

  15. Operating Room Traffic: Is There Any Role of Monitoring It?

    Science.gov (United States)

    Parikh, Shital N.; Grice, Salih S.; Schnell, Beverly M.; Salisbury, Shelia R.

    2010-01-01

    Background Operating room (OR) human traffic has been implicated as a cause of surgical site infection. We first observed the normal human traffic pattern in our Pediatric Orthopaedic ORs, then examined the effect of surveillance on that traffic pattern. Methods This study consisted of two phases: phase I sought to observe the OR traffic pattern (number of door swings, maximum and minimum number of OR personnel, number of OR personnel at 30 minute intervals, or changes in nursing, anesthesia or surgeon staff) during surgical cases without OR personnel being notified, and for phase II, the same traffic pattern was monitored with their knowledge. Results 2442 minutes of surgical time were observed in phase I, and 1908 minutes were observed in phase II. There was no difference (p=0.06) in the time between door swings between phase I (1.39 minutes) and phase II (1.70), no difference (p=1.000) in the maximum number of people in the OR between phase I (11.5 people, range: 7–15 people) and phase II (11.5 people, range: 8–20 people), no difference (p=1.000) in the minimum number of people in the OR between phase I (4.67 people, range: 4–6 people) and phase II (4.71 people, range: 3–6 people). There was a difference in the time between door swings (p=0.03) and maximum number of people in the OR (p=0.005) based on length of surgery (less or more than120 minutes). There was no difference in the time between door swings (p=0.11), but there was a difference in the maximum number of people in the OR (p=0.002) based on type of surgery (spine vs. others). Conclusion There was no role of surveillance of human traffic in the OR. To achieve any change in the OR traffic pattern, monitoring alone may not be sufficient; other novel techniques or incentives may need to be considered. PMID:20733430

  16. Operant Audiometry Manual for Difficult-to-Test Children. Institute on Mental Retardation and Intellectual Development; Papers and Reports, Volume V, Number 19.

    Science.gov (United States)

    Bricker, Diane D.; And Others

    To facilitate the use of operant audiometry with low functioning children (psychotic, severely retarded, or multiply handicapped), a procedures manual was developed containing definitions of terms, instructions for determining reinforcers, physical facilities and equipment needs, diagrams, component lists, and technical descriptions. Development…

  17. TEC MAX System. Operation and Maintenance Manual for the TEC Model 4005 MAX (Miniature Apparatus for X-Ray Diffraction System)

    Science.gov (United States)

    2005-03-31

    Model 4005) TEC has found that residual stress measurements can be made through thin layers of paint on steel surfaces (but not lead-based paints ...indicator lamp Operation and Maintenance Manual 5-11 TEC MAX System (Model 4005) 4005-OM-01 Revision 0, March 31, 2005 XRay Tube Status @ 0 20 40 60

  18. RCRA (Resource Conservation and Recovery Act) personnel training guidance manual for owners or operators of hazardous-waste-management facilities. Draft report

    Energy Technology Data Exchange (ETDEWEB)

    1980-09-01

    The manual provides guidance to an audience consisting of owners or operators of hazardous waste-management facilities and also regulatory personnel responsible for facility permitting. Information is provided concerning general training strategies and program design, types of training, training modules pertinent to hazardous-waste management, suggested training module elements, and sources of information.

  19. Possibilities of making use of integrated emission monitoring system for inspection of electroprecipitators operation

    Energy Technology Data Exchange (ETDEWEB)

    Knitter, J.; Matys, T. [Gdansk Thermal-Electric Power Station Complex S.A., Gdansk (Poland)

    1997-12-31

    Microprocessor and computer control devices for ESP operation and integrated emission monitoring systems are discussed. An operating ESP inspection system for the Gdansk power station complex is determined. 8 refs., 1 fig.

  20. Mine detection performance comparison between manual sweeping and tele-operated robotic system

    Science.gov (United States)

    Herman, Herman; Higgins, Todd; Falmier, Olga; Valois, Jean-Sebastien; McMahill, Jeff

    2010-04-01

    Mine detection is a dangerous and physically demanding task that is very well-suited for robotic applications. In the experiment described in this paper, we try to determine whether a remotely-operated robotic mine detection system equipped with a hand-held mine detector can match the performance of a human equipped with a hand-held mine detector. To achieve this objective, we developed the Robotic Mine Sweeper (RMS). The RMS platform is capable of accurately sweeping and mapping mine lanes using common detectors, such as the Minelab F3 Mine Detector or the AN/PSS-14. The RMS is fully remote controlled from a safe distance by a laptop via a redundant wireless connection link. Data collected from the mine detector and various sensors mounted on the robot are transmitted and logged in real-time to the remote user interface and simultaneously graphically displayed. In addition, a stereo color camera mounted on top of the robot sends a live picture of the terrain. The system plays audio feedback from the detector to further enhance the user's situational awareness. The user is trained to drag and drop various icons onto the user interface map to locate mines and non-mine clutter objects. We ran experiments with the RMS to compare its detection and false alarm rates with those obtained when the user physically sweeps the detectors in the field. The results of two trials: one with the Minelab F3, the other with the Cyterra AN/PSS-14 are presented here.

  1. Local clinical quality monitoring for detection of excess operative deaths.

    Science.gov (United States)

    Arrowsmith, J E; Powell, S J; Nashef, S A M

    2006-05-01

    A monitoring system for cardiac surgery has been in use at Papworth Hospital for 10 years. We wished to determine whether this system would have detected an increase in deaths associated with a single practitioner, whether a poorly performing doctor or a serial killer such as Dr Harold Shipman, whose activities went undetected in the absence of a monitoring system for nearly a quarter of a century. Random extra deaths were artificially introduced into the practice of a surgeon and an anaesthetist in a way that broadly reproduced Shipman's pattern. The standard monitoring system was then used to analyse the hypothetical data thus generated. Using the current standard monitoring, the excess deaths would have been detected in less than 10 months. Suspicions would have been raised even earlier. Robust local quality monitoring of risk-adjusted outcomes is possible and, in our opinion, essential.

  2. Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying (CVD) Facility Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    2000-11-18

    The mission of the Spent Nuclear Fuel (SNF) Project Cold Vacuum Drying Facility (CVDF) is to achieve the earliest possible removal of free water from Multi-Canister Overpacks (MCOs). The MCOs contain metallic uranium SNF that have been removed from the 100K Area fuel storage water basins (i.e., the K East and K West Basins) at the US. Department of Energy Hanford Site in Southeastern Washington state. Removal of free water is necessary to halt water-induced corrosion of exposed uranium surfaces and to allow the MCOs and their SNF payloads to be safely transported to the Hanford Site 200 East Area and stored within the SNF Project Canister Storage Building (CSB). The CVDF is located within a few hundred yards of the basins, southwest of the 165KW Power Control Building and the 105KW Reactor Building. The site area required for the facility and vehicle circulation is approximately 2 acres. Access and egress is provided by the main entrance to the 100K inner area using existing roadways. The CVDF will remove free. water from the MCOs to reduce the potential for continued fuel-water corrosion reactions. The cold vacuum drying process involves the draining of bulk water from the MCO and subsequent vacuum drying. The MCO will be evacuated to a pressure of 8 torr or less and backfilled with an inert gas (helium). The MCO will be sealed, leak tested, and then transported to the CSB within a sealed shipping cask. (The MCO remains within the same shipping Cask from the time it enters the basin to receive its SNF payload until it is removed from the Cask by the CSB MCO handling machine.) The CVDF subproject acquired the required process systems, supporting equipment, and facilities. The cold vacuum drying operations result in an MCO containing dried fuel that is prepared for shipment to the CSB by the Cask transportation system. The CVDF subproject also provides equipment to dispose of solid wastes generated by the cold vacuum drying process and transfer process water removed

  3. Program desk manual for occupational safety and health -- U.S. Department of Energy Richland Operations, Office of Environment Safety and Health

    Energy Technology Data Exchange (ETDEWEB)

    Musen, L.G.

    1998-08-27

    The format of this manual is designed to make this valuable information easily accessible to the user as well as enjoyable to read. Each chapter contains common information such as Purpose, Scope, Policy and References, as well as information unique to the topic at hand. This manual can also be provided on a CD or Hanford Internet. Major topics include: Organization and program for operational safety; Occupational medicine; Construction and demolition; Material handling and storage; Hoisting and rigging; Explosives; Chemical hazards; Gas cylinders; Electrical; Boiler and pressure vessels; Industrial fire protection; Industrial hygiene; and Safety inspection checklist.

  4. 40 CFR 63.2163 - If I monitor fermenter exhaust, what are my monitoring installation, operation, and maintenance...

    Science.gov (United States)

    2010-07-01

    ... Hazardous Air Pollutants: Manufacturing of Nutritional Yeast Testing and Initial Compliance Requirements... are my monitoring installation, operation, and maintenance requirements? 63.2163 Section 63.2163... maintenance requirements? (a) Each CEMS must be installed, operated, and maintained according to the...

  5. Microvibration monitoring: some recent experiences in an operating microelectronics facility

    Science.gov (United States)

    Hassett, Kevin

    1992-02-01

    Major construction work is currently underway at Intel''s Aloha, Oregon, campus. Because of concerns about the effects that construction-generated vibration might have on adjacent ongoing microelectronics manufacturing activities, two important steps were taken. The first of these was to establish guidelines that would be followed by the construction contractor to limit vibration disturbance. The second was to install a computer-based monitoring system that would continuously measure the vibration on the floor of the microelectronics manufacturing facility. In this way, the vibration effects of the construction activities would be monitored and adjusted, by modifying procedures, if necessary. The monitoring program is discussed in this paper. The major characteristics of the monitoring system, the placement of the transducers, and the ways in which the data were managed are described. Some typical data are shown and discussed.

  6. First Operation of the Abort Gap Monitors for LHC

    CERN Document Server

    Bart Pedersen, S; Bravin, E; Boccardi, A; Goldblatt, A; Jeff, A; Roncarolo, F; Fisher, A

    2010-01-01

    The Large Hadron Collider (LHC) beam-dump system relies on extraction kickers that need 3 microseconds to rise to their nominal field. Since particles transiting the kickers during the rise will not be dumped properly, the proton population in this interval must always remain below quench and damage limits. A specific monitor to measure the particle population of this gap has been designed based on the detection of synchrotron radiation using a gated photomultiplier. Since the quench and damage limits change with the beam energy, the acceptable population in the abort gap and the settings of the monitor must adapt accordingly. This paper presents the design of the monitor, the calibration procedure and the detector performance with beam.

  7. CH Packaging Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions LLC

    2005-02-28

    This document provides the user with instructions for assembling a payload. All the steps in Subsections 1.2, Preparing 55-Gallon Drum Payload Assembly; 1.3, Preparing "Short" 85-Gallon Drum Payload Assembly (TRUPACT-II and HalfPACT); 1.4, Preparing "Tall" 85-Gallon Drum Payload Assembly (HalfPACT only); 1.5, Preparing 100-Gallon Drum Payload Assembly; 1.6, Preparing SWB Payload Assembly; and 1.7, Preparing TDOP Payload Assembly, must be completed, but may be performed in any order as long as radiological control steps are not bypassed.

  8. 40 CFR 60.734 - Monitoring of emissions and operations.

    Science.gov (United States)

    2010-07-01

    ... operator of an affected facility subject to the provisions of this subpart who uses a dry control device to... clay vibrating grate dryer, a bentonite rotary dryer, a diatomite flash dryer, a diatomite rotary... section. (d) The owner or operator of an affected facility subject to the provisions of this subpart...

  9. 40 CFR 60.153 - Monitoring of operations.

    Science.gov (United States)

    2010-07-01

    ...) The owner or operator of any multiple hearth, fluidized bed, or electric sludge incinerator subject to...) Install, calibrate, maintain and operate temperature measuring devices at every hearth in multiple hearth... zones of electric incinerators. For multiple hearth furnaces, a minimum of one temperature...

  10. The Key Indicator Method for Manual Handling Operations (KIM-MHO - evaluation of a new method for the assessment of working conditions within a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Gebhardt Hansjürgen

    2010-11-01

    Full Text Available Abstract Background Upper extremity musculoskeletal symptoms and disorders are common in the working population. The economic and social impact of such disorders is considerable. Long-time, dynamic repetitive exposure of the hand-arm system during manual handling operations (MHO alone or in combination with static and postural effort are recognised as causes of musculoskeletal symptoms and disorders. The assessment of these manual work tasks is crucial to estimate health risks of exposed employees. For these work tasks, a new method for the assessment of the working conditions was developed by the Federal Institute for Occupational Safety and Health (BAuA and released as a draft in the year 2007. The draft of the so-called Key Indicator Method for Manual Handling Operations (KIM-MHO was developed in analogy with the existing KIM for Lifting/Holding/Carrying (KIM-LHC and Pulling/Pushing (KIM-PP of loads. The KIM-MHO is designed to fill the gap existing in risk assessment of manual work processes, since the existing KIMs deal only with manual handling of loads. This research project focused on the following: - Examination of the validity of workplace assessment with the KIM-MHO comparing expert ratings with the results of the observations. - Examination of the objectivity of workplace assessment with the KIM-MHO applied by different examiners. - Examination of the criterion validity of the risk assessment provided by KIM-MHO with respect to the association between exposure and the occurrence and prevalence of health related outcomes. Methods/Design To determine the objectivity and validity of workplace assessment, the KIM-MHO is applied by occupational health and safety officers at different workplaces involving manual handling operations. To determine the criterion validity of risk assessment, a survey of employees at different workplaces takes place with standardised questionnaires and interviews about symptoms in the neck and upper extremities

  11. Operation and monitoring guidelines and the development of a ...

    African Journals Online (AJOL)

    2009-03-31

    Mar 31, 2009 ... 35 No. 4 July 2009. ISSN 1816-7950 = Water SA (on-line). 379 ... Keywords: irrigation, coal mine water, monitoring guidelines. Introduction .... production of several crops irrigated with gypsiferous mine water was tested in a ...

  12. Integrating Social Media Monitoring Into Public Health Emergency Response Operations.

    Science.gov (United States)

    Hadi, Tamer A; Fleshler, Keren

    2016-10-01

    Social media monitoring for public health emergency response and recovery is an essential response capability for any health department. The value of social media for emergency response lies not only in the capacity to rapidly communicate official and critical incident information, but as a rich source of incoming data that can be gathered to inform leadership decision-making. Social media monitoring is a function that can be formally integrated into the Incident Command System of any response agency. The approach to planning and required resources, such as staffing, logistics, and technology, is flexible and adaptable based on the needs of the agency and size and scope of the emergency. The New York City Department of Health and Mental Hygiene has successfully used its Social Media Monitoring Team during public health emergency responses and planned events including major Ebola and Legionnaires' disease responses. The concepts and implementations described can be applied by any agency, large or small, interested in building a social media monitoring capacity. (Disaster Med Public Health Preparedness. 2016;page 1 of 6).

  13. Silicon solar cell monitors high temperature furnace operation

    Science.gov (United States)

    Zellner, G. J.

    1968-01-01

    Silicon solar cell, attached to each viewpoint, monitors that incandescent emission from the hot interior of a furnace without interfering with the test assembly or optical pyrometry during the test. This technique can provide continuous indication of hot spots or provide warning of excessive temperatures in cooler regions.

  14. Real Time Distributed Embedded Oscillator Operating Frequency Monitoring

    Science.gov (United States)

    Pollock, Julie (Inventor); Oliver, Brett D. (Inventor); Brickner, Christopher (Inventor)

    2013-01-01

    A method for clock monitoring in a network is provided. The method comprises receiving a first network clock signal at a network device and comparing the first network clock signal to a local clock signal from a primary oscillator coupled to the network device.

  15. Monitoring of flash visual evoked potentials during neurosurgical operations.

    Science.gov (United States)

    Cedzich, C; Schramm, J

    1990-01-01

    In summary, our results suggest that flash VEP monitoring is not specific for visual acuity and has not proved helpful as an intraoperative warning system. The future challenge will be to devise a method which activates only those fibers specific to visual acuity and which provides reproducible and reliable information quickly enough that adjustments in patient management can be made.

  16. The inter- and intra-operator variability in manual spot segmentation and its effect on spot quantitation in two-dimensional electrophoresis analysis.

    Science.gov (United States)

    Millioni, Renato; Sbrignadello, Stefano; Tura, Andrea; Iori, Elisabetta; Murphy, Ellen; Tessari, Paolo

    2010-05-01

    Separation of complex mixtures of proteins by 2-DE is a fundamental component of current proteomic technology. Quantitative analysis of the images generated by digitization of such gels is critical for identifying alterations in protein expression within a given biological system. Software packages are designed for this purpose. The accurate definition of protein spot boundaries, using a suitable method of image segmentation, is a key requirement for image analysis. It is often necessary for operators to intervene manually to correct mistakes in spot segmentation; therefore operator subjectivity and differences in ability can weaken the analysis. We estimated the error in spot quantification after manual spot segmentation, which was performed by different operators, using two different software packages. Our results clearly show that this operation was associated with significant inter- and intra-variability and an overestimation of subsequent spot intensity, especially when spots were weak. For comparative studies, we suggest separately analysing spots which have been manually segmented by imposing a requirement for at least a threefold difference in spot intensity in addition to use of statistical tests.

  17. Standard Operating Procedures, MCSP Monarch and Plant Monitoring, 2016

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This record contains the six Standard Operating Procedure (SOP) of the initial survey instructions (ISI) developed and followed for surveys conducted as part of the...

  18. Structural Health Monitoring in Changing Operational Conditions Using Tranmissibility Measurements

    Directory of Open Access Journals (Sweden)

    Christof Devriendt

    2010-01-01

    Full Text Available This article uses frequency domain transmissibility functions for detecting and locating damage in operational conditions. In recent articles numerical and experimental examples were presented and the possibility to use the transmissibility concept for damage detection seemed quite promising. In the work discussed so far, it was assumed that the operational conditions were constant, the structure was excited by a single input in a fixed location. Transmissibility functions, defined as a simple ratio between two measured responses, do depend on the amplitudes or locations of the operational forces. The current techniques fail in the case of changing operational conditions. A suitable operational damage detection method should however be able to detect damage in a very early stage even in the case of changing operational conditions. It will be demonstrated in this paper that, by using only a small frequency band around the resonance frequencies of the structure, the existing methods can still be used in a more robust way. The idea is based on the specific property that the transmissibility functions become independent of the loading condition in the system poles. A numerical and experimental validation will be given.

  19. Groundwater Monitoring at the 1100-EM-1 Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    Newcomer, Darrell R.

    2007-04-25

    The purpose of this report is to provide a comprehensive summary of the distribution and trends of volatile organic compound concentrations near USDOE’s Horn Rapids Landfill (HRL). This report focuses mainly on the TCE plume monitored in the top of the unconfined aquifer near the HRL, but also addresses potential breakdown products of TCE. TCE concentrations in deep portions of the unconfined aquifer and the underlying confined aquifer are discussed to show the vertical extent of contamination. This report incorporates TCE data from offsite wells at the AREVA facility south of the Hanford Site. Discussion of TCE in groundwater in the 300 Area is included to differentiate between contaminant plumes and their sources in the 300 Area and near the HRL. Chromium monitoring results from a specific well downgradient of the 1171 Building is also included.

  20. Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator's Training.

    Directory of Open Access Journals (Sweden)

    Cristiane do Prado

    Full Text Available To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation.A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece, followed by an analysis of the effectiveness of the equipment according to the participants' education and training.A difference between equipment types was observed for the tidal volume, with a median (interquartile range of 28.5 mL (12.6 for the self-inflating bag and 20.1 mL (8.4 for the T-piece in the instructor group and 31.6 mL (14 for the self-inflating bag and 22.3 mL (8.8 for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator's ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure.The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator's experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag.

  1. Electronic Performance Support for Operational Systems: A Case Study of the Link Monitor and Control Operator Assistant

    Science.gov (United States)

    Hill, Randall W., Jr.; Cooper, Lynne P.

    1993-01-01

    For complex operational systems, help needs to come from the inside out. It is often not realistic to call a help desk for problems that need immediate attention, especially for tasks that put a heavy cognitive load on the system operator. This session addresses the issues associated with providing electronic performance support for operational systems, including situations where the system is already fielded and can only change through evolution rather than revolution. We present a case study based on our experiences in developing the Link Monitor and Control Operator Assistant for NASA's Deep Space Network (DSN). The goals of the Operator Assistant are to improve the operability of the system and increase the efficiency of mission operations.

  2. Optical monitoring and operational modal analysis of large wind turbines

    NARCIS (Netherlands)

    Özbek, M.

    2013-01-01

    Identification of the dynamic properties and the corresponding structural response of wind turbines is essential for optimizing the energy produced, ensuring safe and reliable operation and increasing the life-time of the system. As the sizes of modern wind turbines increase, their dynamic behaviors

  3. 40 CFR 60.115a - Monitoring of operations.

    Science.gov (United States)

    2010-07-01

    ... the sample(s). (c) The true vapor pressure of each type of crude oil with a Reid vapor pressure less...) The owner or operator of each storage vessel equipped with a vapor recovery and return or disposal... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid...

  4. 40 CFR 60.113 - Monitoring of operations.

    Science.gov (United States)

    2010-07-01

    ... the sample(s). (c) The true vapor pressure of each type of crude oil with a Reid vapor pressure less...). (2) Each owner or operator of each affected facility equipped with a vapor recovery and return or... petroleum liquid stored, the period of storage, and the maximum true vapor pressure of that liquid...

  5. Optical monitoring and operational modal analysis of large wind turbines

    NARCIS (Netherlands)

    Özbek, M.

    2013-01-01

    Identification of the dynamic properties and the corresponding structural response of wind turbines is essential for optimizing the energy produced, ensuring safe and reliable operation and increasing the life-time of the system. As the sizes of modern wind turbines increase, their dynamic behaviors

  6. Digital image monitoring to optimise safe port operation

    CSIR Research Space (South Africa)

    Phelp, D

    2008-11-01

    Full Text Available This paper describes a low cost video system ‘Harbour Watch’, which can be used to support safe port operations, especially in developing countries. Preset digital images are geo-referenced and then archived for later analysis to improve...

  7. 40 CFR 60.403 - Monitoring of emissions and operations.

    Science.gov (United States)

    2010-07-01

    ... of the gases discharged into the atmosphere from any phosphate rock dryer, calciner, or grinder. The... operate a device for measuring the phosphate rock feed to any affected dryer, calciner, or grinder. The... phosphate rock dryer, calciner, or grinder subject to paragraph (a) of this section exceeds the...

  8. Groundwater Monitoring Plan for the Reactor Technology Complex Operable Unit 2-13

    Energy Technology Data Exchange (ETDEWEB)

    Richard P. Wells

    2007-03-23

    This Groundwater Monitoring Plan describes the objectives, activities, and assessments that will be performed to support the on-going groundwater monitoring requirements at the Reactor Technology Complex, formerly the Test Reactor Area (TRA). The requirements for groundwater monitoring were stipulated in the Final Record of Decision for Test Reactor Area, Operable Unit 2-13, signed in December 1997. The monitoring requirements were modified by the First Five-Year Review Report for the Test Reactor Area, Operable Unit 2-13, at the Idaho National Engineering and Environmental Laboratory to focus on those contaminants of concern that warrant continued surveillance, including chromium, tritium, strontium-90, and cobalt-60. Based upon recommendations provided in the Annual Groundwater Monitoring Status Report for 2006, the groundwater monitoring frequency was reduced to annually from twice a year.

  9. Learning neuroendoscopy with an exoscope system (video telescopic operating monitor): Early clinical results

    Science.gov (United States)

    Parihar, Vijay; Yadav, Y. R.; Kher, Yatin; Ratre, Shailendra; Sethi, Ashish; Sharma, Dhananjaya

    2016-01-01

    Context: Steep learning curve is found initially in pure endoscopic procedures. Video telescopic operating monitor (VITOM) is an advance in rigid-lens telescope systems provides an alternative method for learning basics of neuroendoscopy with the help of the familiar principle of microneurosurgery. Aims: The aim was to evaluate the clinical utility of VITOM as a learning tool for neuroendoscopy. Materials and Methods: Video telescopic operating monitor was used 39 cranial and spinal procedures and its utility as a tool for minimally invasive neurosurgery and neuroendoscopy for initial learning curve was studied. Results: Video telescopic operating monitor was used in 25 cranial and 14 spinal procedures. Image quality is comparable to endoscope and microscope. Surgeons comfort improved with VITOM. Frequent repositioning of scope holder and lack of stereopsis is initial limiting factor was compensated for with repeated procedures. Conclusions: Video telescopic operating monitor is found useful to reduce initial learning curve of neuroendoscopy.

  10. 14 CFR 121.135 - Manual contents.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Manual contents. 121.135 Section 121.135..., FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.135 Manual contents. (a) Each manual.... (b) The manual may be in two or more separate parts, containing together all of the...

  11. A guidebook for the operation and maintenance of HANARO seismic monitoring analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, Doo Byung; Kim, Hyung Kyoo

    2003-09-01

    Systems and structures related to HANARO safety are classified as seismic category I. Since 1995, the seismic monitoring system has been utilized for monitoring an earthquake at the HANARO site. The existing seismic monitoring system consists of field sensors and monitoring panel. The analog-type monitoring system with magnetic tape recorder is out-of-date model. In addition, the disadvantage of the existing system is that it does not include signal-analyzing equipment. Therefore, we have improved the analog seismic monitoring system into a new digital Seismic Monitoring Analysis System(SMAS) that can offer precise and detail information of the earthquake signals. This newly developed SMAS is operating at the HANARO instrument room to acquire and analyze the signal of an earthquake. This document is a guidebook for the operation and maintenance of the SMAS. The first chapter gives an outline of the SMAS. The second chapter describes functional capability and specification of the hardware. Chapters 3 and 4 describe starting procedure of the SMAS and how to operate the seismic monitoring program, respectively. Chapter 5 illustrates the seismic analysis algorithm used in the SMAS. The way of operating the seismic analysis program is described in chapter 6. Chapter 7 illustrates the calibration procedure for data acquisition module. Chapter 8 describes the symptoms of common malfunctions and its countermeasure suited to the occasions.

  12. Understanding the functions and operations of data monitoring committees: Survey and focus group findings.

    Science.gov (United States)

    Calis, Karim A; Archdeacon, Patrick; Bain, Raymond P; Forrest, Annemarie; Perlmutter, Jane; DeMets, David L

    2017-02-01

    The use of data monitoring committees in the conduct of clinical trials has increased and evolved, but there is a lack of published information on when data monitoring committees are needed and utilized, the acceptable range of data monitoring committee practices, and appropriate qualifications of data monitoring committee members. To gain a better understanding of data monitoring committee operations and areas for improvement, the Clinical Trials Transformation Initiative conducted a survey and set of focus groups. A total of 143 respondents completed the online survey: 76 data monitoring committee members, 52 sponsors involved with organization of data monitoring committees, and 15 statistical data analysis center representatives. There were 42 focus group participants, including data monitoring committee members; patients and/or patient advocate data monitoring committee members; institutional review board and US Food and Drug Administration representatives; industry, government, and non-profit sponsors; and statistical data analysis center representatives. Participants indicated that the primary responsibility of a data monitoring committee is to be an independent advisory body representing the interests of trial participants by assessing the risk and benefit ratio in ongoing trials. They noted that data monitoring committees must have access to unmasked data in order to perform this role. No clear consensus emerged regarding specific criteria for requiring a data monitoring committee for a given trial, and some participants felt data monitoring committees may be overused. Respondents offered suggestions for the data monitoring committee charter and communications with sponsors, institutional review boards, and regulators. Overall, data monitoring committee members reported that they are able to function independently and their recommendations are almost always accepted by the sponsor. Participants indicated that there are no standards or guidelines pertaining

  13. Condition Monitoring of Machinery in Non-Stationary Operations : Proceedings of the Second International Conference "Condition Monitoring of Machinery in Non-Stationnary Operations"

    CERN Document Server

    Bartelmus, Walter; Chaari, Fakher; Zimroz, Radoslaw; Haddar, Mohamed

    2012-01-01

    Condition monitoring of machines in non-stationary operations (CMMNO) can be seen as the major challenge for research in the field of machinery diagnostics. Condition monitoring of machines in non-stationary operations is the title of the presented book and the title of the Conference held in Hammamet - Tunisia March 26 – 28, 2012. It is the second conference under this title, first took place in Wroclaw - Poland , March 2011. The subject CMMNO comes directly from industry needs and observation of real objects. Most monitored and diagnosed objects used in industry works in non-stationary operations condition. The non-stationary operations come from fulfillment of machinery tasks, for which they are designed for. All machinery used in different kind of mines, transport systems, vehicles like: cars, buses etc, helicopters, ships and battleships and so on work in non-stationary operations. The papers included in the book are shaped by the organizing board of the conference and authors of the papers. The papers...

  14. Work flow with manual re-registration of cardiac 18F-FDG PET and attenuation correction CT to compensate for respiratory motion: Effects and inter-operator variability

    DEFF Research Database (Denmark)

    Juhl, Christian; Christensen, Nana Louise; Møller, Lone W.

    cases where the manual re-registration resulted in new artefacts. These were, however, easily identified and eliminated by second technologist in the verification-step resulting in an overall insignificant inter-operator variability. In conclusion, manual re-registration reduces artefacts due...

  15. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  16. Computing shifts to monitor ATLAS distributed computing infrastructure and operations

    CERN Document Server

    Bourdarios, Claire; The ATLAS collaboration; Crepe-Renaudin, Sabine Chrystel; De, Kaushik

    2017-01-01

    The ATLAS Distributed Computing (ADC) group established a new Computing Run Coordinator (CRC) shift at the start of LHC Run2 in 2015. The main goal was to rely on a person with a good overview of the ADC activities to ease the ADC experts' workload. The CRC shifter keeps track of ADC tasks related to their fields of expertise and responsibility. At the same time, the shifter maintains a global view of the day-to-day operations of the ADC system. During Run1, this task was accomplished by the ADC Manager on Duty (AMOD), a position that was removed during the shutdown period due to the reduced number and availability of ADC experts foreseen for Run2. The CRC position was proposed to cover some of the AMOD’s former functions, while allowing more people involved in computing to participate. In this way, CRC shifters help train future ADC experts. The CRC shifters coordinate daily ADC shift operations, including tracking open issues, reporting, and representing ADC in relevant meetings. The CRC also facilitates ...

  17. Development of NPP Monitoring and Operation Support Technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Park, Jae Chang; Lee, Yong Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)] (and others)

    2008-04-15

    During the first stage (2001.7.1-2004.6.30), we developed general human factors design guidelines VDU-based workstations, PMAS alarm display design guidelines, PMAS SPADES display design guidelines, and the revision of KHNP HFE guidelines (HF-010), which have been applied to domestic NPP designs. We also supported other KNICS projects by performing RPS COM design reviews, development of RPS COM Style Guide, and a review of CEDMCS cabinet operator module display design. We developed the ADIOS prototype, NPP performance analysis systems for YGN No.1, 2 plants and Kori No. 2 plant, alarm cause tracking systems for Kori No. 2 plant and OPR1000, and signal fault detection and diagnosis methods for deaerators and steam generators. During the second stage(2004.7.1-2008.4.30), we supported other KNICS projects by reviewing RPS COM display designs three times, developing ESF-CCS COM style guides and reviewing ESF-CCS COM display design, reviewing CRCS LOM and PCS MTP display designs, and developing requirements for DCS GUI components. We also developed integrated style guide for I and C cabinet operator module display designs. In cooperative research with KOPEC-AE, we developed basic technologies for advanced HSI design including task analysis methods, an information and control requirements database, display design criteria, a HSI prototype with its evaluation, and methods for human factors engineering verification and validation.

  18. Computing shifts to monitor ATLAS distributed computing infrastructure and operations

    CERN Document Server

    Adam Bourdarios, Claire; The ATLAS collaboration

    2016-01-01

    The ATLAS Distributed Computing (ADC) group established a new Computing Run Coordinator (CRC) shift at the start of LHC Run2 in 2015. The main goal was to rely on a person with a good overview of the ADC activities to ease the ADC experts' workload. The CRC shifter keeps track of ADC tasks related to their fields of expertise and responsibility. At the same time, the shifter maintains a global view of the day-to-day operations of the ADC system. During Run1, this task was accomplished by the ADC Manager on Duty (AMOD), a position that was removed during the shutdown period due to the reduced number and availability of ADC experts foreseen for Run2. The CRC position was proposed to cover some of the AMOD’s former functions, while allowing more people involved in computing to participate. In this way, CRC shifters help train future ADC experts. The CRC shifters coordinate daily ADC shift operations, including tracking open issues, reporting, and representing ADC in relevant meetings. The CRC also facilitates ...

  19. Geodetic Monitoring System Operating On Neapolitan Volcanic Area (southern Italy)

    Science.gov (United States)

    Pingue, F.; Ov-Geodesy Team

    The Neapolitan volcanic area is located in the southern sector of the Campanian Plain Graben including three volcanic active structures (Somma-Vesuvius, Campi Flegrei and Ischia). The Somma-Vesuvius complex, placed East of Naples, is a strato-volcano composed by a more ancient apparatus (Mt. Somma) and a younger cone (Mt. Vesu- vius) developed inside Somma caldera. Since last eruption (1944) it is in a quiescent state characterised by a low level seismicity and deformation activity. The Campi Fle- grei, located West of Naples, are a volcanic field inside an older caldera rim. The last eruption, occurred in the 1538, built up the Mt. Nuovo cone. The Campi Flegrei are subject to a slow vertical deformation, called bradyseism. In the 1970-1972 and 1982-1984 they have been affected by two intense episodes of ground upheaval (ac- companied by an intense seismic activity)0, followed by a subsidence phase, slower than uplift and still active. Though such phenomenon has not been followed by erup- tive events, it caused serious damages, emphasizing the high volcanic risk of the phle- grean caldera. The Ischia island, located SW of Naples, has been characterised by a volcanic activity both explosive and effusive, occurred mainly in the last 50,000 years. These events modelled the topography producing fault systems and structures delim- iting the Mt. Epomeo resurgent block. The last eruption has occurred on 1302. After, the dynamics of the island has been characterised by seismic activity (the strongest earthquake occurred on 1883) and by a meaningful subsidence, on the S and NW sec- tors of the island. The concentration of such many active volcanoes in an area with a dense urbanization (about 1,500,000 inhabitants live) needs systematic and contin- uous monitoring of the dynamics. These information are necessary in order to char- acterise eruptive precursors useful for modelling the volcanoes behaviour. Insofar, the entire volcanic Neapolitan area, characterised by a

  20. Fuel Cell Power System and Equipment Bay for High Altitude, Super- Pressured, Powered Aerostat (HASPA) Operational Manual

    Science.gov (United States)

    1975-05-20

    Identify hy block number) Fuel cell High altitude Power system Aerostat f HASPA Manual .A8SRACt (Continue on reverse aide If rI coeeary and identify...Control Unit 37 VI. Pin Identification - Fuel Cell Control Unit 38 VIH . Pin Identification - Fuel Cell Auxiliary Data Unit 39 - VIII. HASPA - Equipment

  1. SIMONS: Ship Monitoring System Support Tactical and Operational Missions

    Science.gov (United States)

    Margarit, Gerard

    2016-08-01

    This paper presents the latest results that have been obtained by GMV in the Maritime Surveillance and Awareness (MSA) domain through the exploitation of the SIMONS suite within fully operational scenarios. Diversified actors have been interacted with from pure public authorities to pure private companies for different specific goals. Scenario conditions were also varying in terms of area and target of interest, input data sources, ancillary datasets and dissemination strategies. The results show that SIMONS is a very useful tool in MSA that can complement the tactical and strategic information that can be obtained through in-situ and classical surveillance means (airborne- and ship-based visual reconnaissance...). Beyond timely delivery of reports, the capability to detect small non-metallic targets and to categorize most of the detected spots are two of the most prominent and recognized features.

  2. Evaluation of objectivity, reliability and criterion validity of the key indicator method for manual handling operations (KIM-MHO), draft 2007.

    Science.gov (United States)

    Klußmann, André; Gebhardt, Hansjürgen; Rieger, Monika; Liebers, Falk; Steinberg, Ulf

    2012-01-01

    Upper extremity musculoskeletal symptoms and disorders are common in the working population. The economic and social impact of such disorders is considerable. Long-time, dynamic repetitive exposure of the hand-arm system during manual handling operations (MHO) alone or in combination with static and postural effort are recognised as causes of musculoskeletal symptoms and disorders. The assessment of these manual work tasks is crucial to estimate health risks of exposed employees. For these work tasks, a new method for the assessment of the working conditions was developed and a validation study was performed. The results suggest satisfying criterion validity and moderate objectivity of the KIM-MHO draft 2007. The method was modified and evaluated again. It is planned to release a new version of KIM-MHO in spring 2012.

  3. Computer monitors and controls all truck-shovel operations

    Energy Technology Data Exchange (ETDEWEB)

    Chironis, N.P.

    1985-03-01

    The intense competition in the coal industry and the advances in computer technology have led several large mines to consider computer dispatching systems as a means of optimizing production. Quintette Coal, Ltd., of Vancouver, B.C., has engaged Modular Mining Systems, Inc., of Tucson, to install a comprehensive truck-dispatch system at a new, multiseam mine northeast of Vancouver. This open-pit operation will rely on truck-shovel teams to uncover both steam and metallurgical coal. The mine is already using about 12 shovels and 50 trucks to produce 3 million tpy. By 1986, production will hit 5 million tpy of metallurgical coal and 1.3 million tpy of steam coal. The coal is under contract to be shipped to Japan. Denison Mines Ltd., owns 50% of Quintette Coal. Of the other 14 shareholders, 10 are Japanese steel companies. Although about 10 non-coal mines worldwide are using some form of computer-controlled dispatching system, Quintette is the first coal company to do so and western US mines are reportedly studying the Quintette system carefully.

  4. Operational-Condition-Independent Criteria Dedicated to Monitoring Wind Turbine Generators: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, W.; Sheng, S.; Court, R.

    2012-08-01

    To date the existing wind turbine condition monitoring technologies and commercially available systems have not been fully accepted for improving wind turbine availability and reducing their operation and maintenance costs. One of the main reasons is that wind turbines are subject to constantly varying loads and operate at variable rotational speeds. As a consequence, the influences of turbine faults and the effects of varying load and speed are coupled together in wind turbine condition monitoring signals. So, there is an urgent need to either introduce some operational condition de-coupling procedures into the current wind turbine condition monitoring techniques or develop a new operational condition independent wind turbine condition monitoring technique to maintain high turbine availability and achieve the expected economic benefits from wind. The purpose of this paper is to develop such a technique. In the paper, three operational condition independent criteria are developed dedicated for monitoring the operation and health condition of wind turbine generators. All proposed criteria have been tested through both simulated and practical experiments. The experiments have shown that these criteria provide a solution for detecting both mechanical and electrical faults occurring in wind turbine generators.

  5. Monitoring System for Farming Operations with Wearable Devices Utilized Sensor Networks

    Directory of Open Access Journals (Sweden)

    Tokihiro Fukatsu

    2009-08-01

    Full Text Available In order to automatically monitor farmers’ activities, we propose a farm operation monitoring system using “Field Servers” and a wearable device equipped with an RFID reader and motion sensors. Our proposed system helps in recognizing farming operations by analyzing the data from the sensors and detected RFID tags that are attached to various objects such as farming materials, facilities, and machinery. This method can be applied to various situations without changing the conventional system. Moreover, this system provides useful information in real-time and controls specific machines in a coordinated manner on the basis of recognized operation.

  6. Monitoring System for Farming Operations with Wearable Devices Utilized Sensor Networks

    Science.gov (United States)

    Fukatsu, Tokihiro; Nanseki, Teruaki

    2009-01-01

    In order to automatically monitor farmers’ activities, we propose a farm operation monitoring system using “Field Servers” and a wearable device equipped with an RFID reader and motion sensors. Our proposed system helps in recognizing farming operations by analyzing the data from the sensors and detected RFID tags that are attached to various objects such as farming materials, facilities, and machinery. This method can be applied to various situations without changing the conventional system. Moreover, this system provides useful information in real-time and controls specific machines in a coordinated manner on the basis of recognized operation. PMID:22454578

  7. Installation and Operation of RENO Slow Control and Online Monitoring System

    CERN Document Server

    Choi, J H; Pac, M Y; Ahn, J K; Choi, S; Choi, Y; Choi, W K; Jang, J S; Jeon, E J; Joo, K K; Kim, H S; Kim, J Y; Kim, S B; Kim, W; Kim, Y D; Lee, J; Lim, I T; Ma, K J; Park, I G; Park, J S; Park, K S; Shin, J W; K, Siyeon; Stepanyan, S S; Yeo, I S; Yu, I

    2013-01-01

    The RENO is the reactor based experiment to measure the smallest neutrino mixing angle, $\\theta_{13}$. The slow control and online monitoring system for RENO monitors the status of the HV systems, the temperatures of the electronics crates and detectors, the fluids levels, humidities of experimental halls and electronics huts, and gas concentrations. And the slow control system is able to set up high voltage for each channel and turn on and off HV remotely. An online monitoring system located in the control room reads data from the DAQ host computer via network. It provides event display, online histograms to monitor detector performance, and variety of additional tasks needed to efficiently monitor detector performance parameters and diagnose troubles of detector and DAQ system. In this paper, we explan the installation of the slow control and monitoring system and their operation status,

  8. Assessing the effects of manual dexterity and playing computer games on catheter-wire manipulation for inexperienced operators.

    Science.gov (United States)

    Alsafi, Z; Hameed, Y; Amin, P; Shamsad, S; Raja, U; Alsafi, A; Hamady, M S

    2017-09-01

    To investigate the effect of playing computer games and manual dexterity on catheter-wire manipulation in a mechanical aortic model. Medical student volunteers filled in a preprocedure questionnaire assessing their exposure to computer games. Their manual dexterity was measured using a smartphone game. They were then shown a video clip demonstrating renal artery cannulation and were asked to reproduce this. All attempts were timed. Two-tailed Student's t-test was used to compare continuous data, while Fisher's exact test was used for categorical data. Fifty students aged 18-22 years took part in the study. Forty-six completed the task at an average of 168 seconds (range 103-301 seconds). There was no significant difference in the dexterity score or time to cannulate the renal artery between male and female students. Students who played computer games for >10 hours per week had better dexterity scores than those who did not play computer games: 9.1 versus 10.2 seconds (p=0.0237). Four of 19 students who did not play computer games failed to complete the task, while all of those who played computer games regularly completed the task (p=0.0168). Playing computer games is associated with better manual dexterity and ability to complete a basic interventional radiology task for novices. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

    Science.gov (United States)

    Iverson, David L.; Spirkovska, Lilly; Schwabacher, Mark

    2010-01-01

    Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

  10. 手工作业对作业治疗教学效果的影响①%Effect of Manual Operation on Teaching of Occupational Therapy

    Institute of Scientific and Technical Information of China (English)

    朱毅; 李凝; 闫彦宁; 黄眀威; 马全胜

    2013-01-01

      目的评价手工作业对作业疗法学教学效果的影响。方法将83名学生随机分为常规教学组41人和手工作业教学组42人,分别采用常规教学法和手工作业教学法。4学时教学后采用加拿大职业行为模式(CMOP)评估量表对教学效果进行评价。结果常规教学组和手工作业教学组分别收回37份、41份问卷,两组各有2份及3份不完整被剔除。在课堂氛围和谐生动、课程内容激发兴趣、教师能充分讲解课程内涵、掌握一定的职业思想、培养解决实际问题的能力、培养良好医患沟通技巧、课堂讨论能够激发活跃思维7个方面,手工作业教学组明显优于常规教学组(P<0.01)。结论手工作业是一种新型、有效、便捷、低成本的教学模式,能提高作业治疗教学水平。%Objective To investigate the effect of manual operation on occupational therapy teaching. Methods 83 students were ran-domly divided into 2 groups:41 students of general teaching group and the other 42 of manual operation teaching group, who received the ordinary classroom teaching and manual operation teaching respectively. After 4 h of study, they were measured with Canadian Model of Oc-cupational Performance (CMOP). Results There were 37 and 41 questionnaires recalled from the general teaching group and the manual op-eration teaching group, and 2 and 3 questionnaires excluded as incomplete respectively. The scores of the classroom atmosphere, interesting stimulation, explanation of curriculum connotation, obtaining professional ideology, ability cultivated to solve practical problems, good rela-tionship between doctors and patients developing, and thinking of discussion stimulating were more in the manual operation teaching group than in the general teaching group (P<0.01). Conclusion Manual operation is a new, effective, convenient, and low-cost mode of teaching for occupational therapy.

  11. Quantitative comparison of operative skill using 2- and 3-dimensional monitors during laparoscopic phantom tasks.

    Science.gov (United States)

    Nishi, Masayasu; Kanaji, Shingo; Otake, Yoshito; Harada, Hitoshi; Yamamoto, Masashi; Oshikiri, Taro; Nakamura, Tetsu; Suzuki, Satoshi; Suzuki, Yuki; Hiasa, Yuta; Sato, Yoshinobu; Kakeji, Yoshihiro

    2017-05-01

    The recent development of stereoscopic images using 3-dimensional monitors is expected to improve techniques for laparoscopic operation. Several studies have reported technical advantages in using 3-dimensional monitors with regard to operative accuracy and working speed, but there are few reports that analyze forceps motions by 3-dimensional optical tracking systems during standardized laparoscopic phantom tasks. We attempted to develop a 3-dimensional motion analysis system for assessing laparoscopic tasks and to clarify the efficacy of using stereoscopic images from a 3-dimensional monitor to track forceps movement during laparoscopy. Twenty surgeons performed 3 tasks (Task 1: a simple operation by the dominant hand, Task 2: a simple operation using both hands, Task 3: a complicated operation using both hands) under 2-dimensional and 3-dimensional systems. We tracked and recorded the motion of forceps tips with an optical marker captured by a 3-dimensional position tracker. We analyzed factors such as forceps path lengths, operation times, and technical errors for each task and compared the results of 2-dimensional and 3-dimensional monitors. Mean operation times and technical errors were improved significantly for all tasks performed under the 3-dimensional system compared with the 2-dimensional system; in addition, mean path lengths for the forceps tips were shorter for all tasks performed under the 3-dimensional system. We found that stereoscopic images using a 3-dimensional monitor improved operative techniques with regard to increased accuracy and shorter path lengths for forceps movement, which resulted in a shorter operation time for basic phantom laparoscopic tasks. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Does a 4 diagram manual enable laypersons to operate the laryngeal mask supreme®? A pilot study in the manikin

    Directory of Open Access Journals (Sweden)

    Schälte Gereon

    2012-03-01

    Full Text Available Abstract Background Bystander resuscitation plays an important role in lifesaving cardiopulmonary resuscitation (CPR. A significant reduction in the "no-flow-time", quantitatively better chest compressions and an improved quality of ventilation can be demonstrated during CPR using supraglottic airway devices (SADs. Previous studies have demonstrated the ability of inexperienced persons to operate SADs after brief instruction. The aim of this pilot study was to determine whether an instruction manual consisting of four diagrams enables laypersons to operate a Laryngeal Mask Supreme® (LMAS in the manikin. Methods An instruction manual of four illustrations with speech bubbles displaying the correct use of the LMAS was designed. Laypersons were handed a bag containing a LMAS, a bag mask valve device (BMV, a syringe prefilled with air and the instruction sheet, and were asked to perform and ventilate the manikin as displayed. Time to ventilation was recorded and degree of success evaluated. Results A total of 150 laypersons took part. Overall 145 participants (96.7% inserted the LMAS in the manikin in the right direction. The device was inserted inverted or twisted in 13 (8.7% attempts. Eight (5.3% individuals recognized this and corrected the position. Within the first 2 minutes 119 (79.3% applicants were able to insert the LMAS and provide tidal volumes greater than 150 ml (estimated dead space. Time to insertion and first ventilation was 83.2 ± 29 s. No significant difference related to previous BLS training (P = 0.85, technical education (P = 0.07 or gender could be demonstrated (P = 0.25. Conclusion In manikin laypersons could insert LMAS in the correct direction after onsite instruction by a simple manual with a high success rate. This indicates some basic procedural understanding and intellectual transfer in principle. Operating errors (n = 91 were frequently not recognized and corrected (n = 77. Improvements in labeling and the quality of

  13. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility); Betriebshandbuch fuer die Mehrzweck-Thermohydraulikversuchsanlage TOPFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S. [SAAS Systemanalyse und Automatisierungsservice GmbH, Possendorf (Germany)

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  14. Environmental Monitoring Plan United States Department of Energy Richland Operations Office. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-10

    This Environmental Monitoring Plan was prepared for the US Department of Energy`s (DOE`s) Richland Operations Office (RL) to implement the requirements of DOE Order 5400.1. According to the Order, each DOE site, facility, or activity that uses, generates, releases, or manages significant pollutants or hazardous materials shall prepare a written environmental monitoring plan covering two major activities: (1) effluent monitoring and (2) environmental surveillance. The plan is to contain information discussing the rationale and design criteria for the monitoring programs, sampling locations and schedules, quality assurance requirements, program implementation procedures, analytical procedures, and reporting requirements. The plan`s purpose is to assist DOE in the management of environmental activities at the Hanford Site and to help ensure that operations on the site are conducted in an environmentally safe and sound manner.

  15. 4th International Conference on Condition Monitoring of Machinery in Non-Stationary Operations

    CERN Document Server

    Zimroz, Radoslaw; Bartelmus, Walter; Haddar, Mohamed

    2016-01-01

    The book provides readers with a snapshot of recent research and technological trends in the field of condition monitoring of machinery working under a broad range of operating conditions. Each chapter, accepted after a rigorous peer-review process, reports on an original piece of work presented and discussed at the 4th International Conference on Condition Monitoring of Machinery in Non-stationary Operations, CMMNO 2014, held on December 15-16, 2014, in Lyon, France. The contributions have been grouped into three different sections according to the main subfield (signal processing, data mining, or condition monitoring techniques) they are related to. The book includes both theoretical developments as well as a number of industrial case studies, in different areas including, but not limited to: noise and vibration; vibro-acoustic diagnosis; signal processing techniques; diagnostic data analysis; instantaneous speed identification; monitoring and diagnostic systems; and dynamic and fault modeling. This book no...

  16. Operational-Condition-Independent Criteria Dedicated to Monitoring Wind Turbine Generators

    Directory of Open Access Journals (Sweden)

    Richard Court

    2013-01-01

    Full Text Available Condition monitoring is beneficial to the wind industry for both onshore and offshore plants. However, due to the variations in operational conditions, its potential has not been fully explored. There is a need to develop an operational-condition-independent condition monitoring technique, which has motivated the research presented here. In this paper, three operational-condition-independent criteria are developed. The criteria accomplish the condition monitoring by analyzing the wind turbine electrical signals in the time domain. Therefore, they are simple to calculate and ideal for online use. All proposed criteria were tested through both simulated and practical experiments. The experiments have shown that these criteria not only provide a solution for detecting both mechanical and electrical faults that occur in wind turbine generators, but provide a potential tool for diagnosing generator winding faults.

  17. Design, calibration, and operation of 220Rn stack effluent monitoring systems at Argonne National Laboratory.

    Science.gov (United States)

    Munyon, W J; Kretz, N D; Marchetti, F P

    1994-09-01

    A group of stack effluent monitoring systems have been developed to monitor discharges of 220Rn from a hot cell facility at Argonne National Laboratory. The stack monitors use flow-through scintillation cells and are completely microprocessor-based systems. A method for calibrating the stack monitors in the laboratory and in the field is described. A nominal calibration factor for the stack monitoring systems in use is 15.0 cts min-1 per kBq m-3 (0.56 cts min-1 per pCi L-1) +/- 26% at the 95% confidence level. The plate-out fraction of decay products in the stack monitor scintillation cells, without any pre-filtering, was found to be nominally 25% under normal operating conditions. When the sample was pre-filtered upstream of the scintillation cell, the observed cell plate-out fraction ranged from 16-22%, depending on the specific sampling conditions. The instantaneous 220Rn stack concentration can be underestimated or overestimated when the steady state condition established between 220Rn and its decay products in the scintillation cell is disrupted by sudden changes in the monitored 220Rn concentration. For long-term measurements, however, the time-averaged response of the monitor represents the steady state condition and leads to a reasonable estimate of the average 220Rn concentration during the monitoring period.

  18. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen....

  19. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your...

  20. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete...

  1. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon...

  2. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen...

  3. Significance of Operating Environment in Condition Monitoring of Large Civil Structures

    Directory of Open Access Journals (Sweden)

    Sreenivas Alampalli

    1999-01-01

    Full Text Available Success of remote long-term condition monitoring of large civil structures and developing calibrated analytical models for damage detection, depend significantly on establishing accurate baseline signatures and their sensitivity. Most studies reported in the literature concentrated on the effect of structural damage on modal parameters without emphasis on reliability of modal parameters. Thus, a field bridge structure was studied for the significance of operating conditions in relation to baseline signatures. Results indicate that in practice, civil structures should be monitored for at least one full cycle of in-service environmental changes before establishing baselines for condition monitoring or calibrating finite-element models. Boundary conditions deserve special attention.

  4. PHYSIOLOGICAL MONITORING OPERATORS ACS IN AUDIO-VISUAL SIMULATION OF AN EMERGENCY

    Directory of Open Access Journals (Sweden)

    S. S. Aleksanin

    2010-01-01

    Full Text Available In terms of ship simulator automated control systems we have investigated the information content of physiological monitoring cardiac rhythm to assess the reliability and noise immunity of operators of various specializations with audio-visual simulation of an emergency. In parallel, studied the effectiveness of protection against the adverse effects of electromagnetic fields. Monitoring of cardiac rhythm in a virtual crash it is possible to differentiate the degree of voltage regulation systems of body functions of operators on specialization and note the positive effect of the use of means of protection from exposure of electromagnetic fields.

  5. The ATLAS Trigger Monitoring and Operations in proton-proton collisions

    CERN Document Server

    The ATLAS collaboration

    2010-01-01

    With the first proton-proton collisions at $\\sqrt{s}=900~\\mathrm{GeV}$ in December 2009, the full chain of the ATLAS Trigger and Data Acquisition system could be tested with real conditions for the first time. Monitoring the performance and operation of these systems required a smooth and parallel running of many complex software tools depending on each other. They are the basis of rate measurements, data quality determination of selected objects and supervision of the system during the data taking. Based on the successful data taking experience with first collisions, the ATLAS trigger monitoring and operations performance are described.

  6. RCRA and operational monitoring 1994 fiscal year work plan, WBS 1.5.3

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    RCRA & Operational Monitoring (ROM) Program Office manages the direct funded Resource Conservation Recovery Act (RCRA) and Operational Monitoring under Work Breakdown Structure (WBS) 1.5.3. The ROM Program Office is a Branch of liquid Waste Disposal, a part of Restoration and Remediation of Westinghouse Hanford Company (WHC). The Fiscal Year Work Plan (FYWP) takes it direction from the Multi-Year Program Plan (MYPP). The FYWP provides the near term, enhanced details for the Program Office to use as baseline Cost, Scope and Schedule. Changs Control administered during the fiscal year is against the baseline provided by the FYWP.

  7. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  8. A technical system to improve the operational monitoring of the Zaporozhye nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, M.; Carl, H.; Nowak, K. [Technischer Ueberwachungsverein Rheinland, Koeln (Germany). Inst. for Nuclear Engineering and Radiation Protection; Schumann, P.; Seidel, A.; Weiss, F.P.; Zschau, J.

    1998-10-01

    As part of the programme implemented by the German Ministry of Environment, Nature Conservation and Reactor Safety to cooperate with the Central and Eastern European States (CEES) and the Commonwealth of Independent States (CIS) in the area of nuclear safety, a technical system to improve operational monitoring has been designed, specified and established since 1992 as a pilot project in the Zaporozhye/Ukraine nuclear power plant by Forschungszentrum Rossendorf and Technischer Ueberwachungsverein Rheinland with a significant contribution from the State Scientific and Technical Centre of the Ukrainian supervisory authority. The technical system complements existing operational checking and monitoring facilities by including modern means of information technology. It enables a continuous monitoring of the state of unit 5 in normal operation and in cases of anomalies or incidents so that when recognisable deviations from the regular plant operation occur, the Ukrainian supervisory authority can immediately inquire and if necessary impose conditions on the operator. The radiological and meteorological parameters at the nuclear power plant location are monitored to the extent necessary to assess the current radiation situation and to implement efficient emergency management measures. (orig.)

  9. Data Processing Concepts for the Integration of SAR Into Operational Volcano Monitoring Systems

    Science.gov (United States)

    Meyer, F. J.; McAlpin, D. B.; Gong, W.; Arko, S.; Webley, P. W.; Dehn, J.

    2013-05-01

    Remote Sensing plays a critical role in operational volcano monitoring due to the often remote locations of volcanic systems and the large spatial extent of potential eruption pre-cursor signals. Despite the all-weather capabilities of radar remote sensing and despite its high performance in monitoring change, the contribution of radar data to operational monitoring activities has been limited in the past. This is largely due to (1) the high data costs associated with radar data, (2) the slow data processing and delivery procedures, and (3) the limited temporal sampling provided by spaceborne radars. With this paper, we present new data processing and data integration techniques that mitigate some of the above mentioned limitations and allow for a meaningful integration of radar remote sensing data into operational volcano monitoring systems. The data integration concept presented here combines advanced data processing techniques with fast data access procedures in order to provide high quality radar-based volcano hazard information at improved temporal sampling rates. First performance analyses show that the integration of SAR can significantly improve the ability of operational systems to detect eruptive precursors. Therefore, the developed technology is expected to improve operational hazard detection, alerting, and management capabilities.

  10. Irrigation Training Manual. Planning, Design, Operation, and Management of Small-Scale Irrigation Systems [and] Irrigation Reference Manual. A Technical Reference to Be Used with the Peace Corps Irrigation Training Manual T0076 in the Selection, Planning, Design, Operation, and Management of Small-Scale Irrigation Systems.

    Science.gov (United States)

    Salazar, LeRoy; And Others

    This resource for trainers involved in irrigated agriculture training for Peace Corps volunteers consists of two parts: irrigation training manual and irrigation reference manual. The complete course should fully prepare volunteers serving as irrigation, specialists to plan, implement, evaluate and manage small-scale irrigation projects in arid,…

  11. Integrating SAR and derived products into operational volcano monitoring and decision support systems

    Science.gov (United States)

    Meyer, F. J.; McAlpin, D. B.; Gong, W.; Ajadi, O.; Arko, S.; Webley, P. W.; Dehn, J.

    2015-02-01

    Remote sensing plays a critical role in operational volcano monitoring due to the often remote locations of volcanic systems and the large spatial extent of potential eruption pre-cursor signals. Despite the all-weather capabilities of radar remote sensing and its high performance in monitoring of change, the contribution of radar data to operational monitoring activities has been limited in the past. This is largely due to: (1) the high costs associated with radar data; (2) traditionally slow data processing and delivery procedures; and (3) the limited temporal sampling provided by spaceborne radars. With this paper, we present new data processing and data integration techniques that mitigate some of these limitations and allow for a meaningful integration of radar data into operational volcano monitoring decision support systems. Specifically, we present fast data access procedures as well as new approaches to multi-track processing that improve near real-time data access and temporal sampling of volcanic systems with SAR data. We introduce phase-based (coherent) and amplitude-based (incoherent) change detection procedures that are able to extract dense time series of hazard information from these data. For a demonstration, we present an integration of our processing system with an operational volcano monitoring system that was developed for use by the Alaska Volcano Observatory (AVO). Through an application to a historic eruption, we show that the integration of SAR into systems such as AVO can significantly improve the ability of operational systems to detect eruptive precursors. Therefore, the developed technology is expected to improve operational hazard detection, alerting, and management capabilities.

  12. Towards the development of integrated monitoring system for retreat mining operations

    Institute of Scientific and Technical Information of China (English)

    HAMID Maleki

    2008-01-01

    Through cooperative research between the government, the private sector,mining companies and equipment manufacturers, considerable progress had been madeduring the last decade in studying the mechanics of strata failure and acquiring the know-ledge needed to develop an integrated monitoring system for assessing local roof stability.Because of higher geotechnical risks in retreat mining operations, it was both important todevelop panel layout designs that control convergence and stress and to monitor groundresponse during operations to verify designs and provide warning of impending stabilityproblems. For detecting both localized roof stability problems and global overburden col-lapse mechanisms, the proposes an integrated panel-wide monitoring system which com-bines the capabilities of load rate monitoring of mobile roof supports (MRSs) with deforma-tion measurements using an extensive array of sensors located near the mining face andthroughout the panel. Two monitoring methods for the detection of localized roof stabilityproblems have been evaluated on the basis of mine measurements and numerical model-ing considerations. These are load rate monitoring of the hydraulic cylinders of mobile roofsupport (MRS) and re mote monitoring of roof movements. Analyses of field data in retreatsections show that roof instabilities are influenced by: (1) pillar failure, (2) pillar yielding, (3)mine seismicity (bumps), (4) geologic structures, and (5) panel layout designs and practice.Pillar yielding and unloading can be conveniently monitored by the load rate monitoringdevice, but to detect impending localized roof falls, additional ground deformation meas-urements are needed near the mining face. By increasing the number of deformationmeasurements in the entire panel, additional safeguards can be achieved for detectingoverburden collapse mechanisms while continuously monitoring local roof stability close tothe retreat line.

  13. Operational Use of the Air Quality Monitor on ISS and Potential for Air Quality Monitoring Onboard Submarines

    Science.gov (United States)

    Limero, Thomas; Jones, Jared; Wallace, William; Mudgett, Paul

    2015-01-01

    The air quality monitor (AQM) began operations on the International Space Station (ISS) in March 2013 and was validated for operational use in January 2014. The AQM is a gas chromatograph-differential mobility spectrometer that currently monitors 22 target compounds in the ISS atmosphere. Data are collected twice per week, although data collection can be more frequent in contingency situations. In its second year, the AQM has provided data to decision-makers on several ISS contaminant related issues in both air and water. AQM has been used in strictly air incidents, such as a potential ammonia leak, and to investigate air contaminants affecting the water processing (excess ethanol). In the latter case data from water monitors and AQM were compared to understand the issue with the water processor. Additionally, the AQM has been moved to different ISS modules to determine whether air is sufficiently mixed between modules so that a central LAB module location is representative of the entire ISS atmosphere. Historic data on the ISS atmosphere in different modules from archival samples (ground lab analysis) suggest that the atmosphere is usually homogenous. This presentation will briefly describe the technical aspects of the AQM operations and summarize the validation results. The main focus of the presentation will be to discuss the results from the AQM survey of the ISS modules and to show how the AQM data has contributed to an understanding of environmental issues that have arisen on ISS. Presentation of a potential ammonia leak (indicated by an alarm) in 2015 will illustrate the use and value of the AQM in such situations.

  14. Hanford Internal Dosimetry Program Manual, PNL-MA-552

    Energy Technology Data Exchange (ETDEWEB)

    Carbaugh, Eugene H.; Bihl, Donald E.; Maclellan, Jay A.

    2009-09-24

    This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

  15. 40 CFR 60.107a - Monitoring of emissions and operations for fuel gas combustion devices.

    Science.gov (United States)

    2010-07-01

    ... this section will be considered inherently low in sulfur content. (i) Pilot gas for heaters and flares... content in the fuel gas stream going to the loading rack flare). (2) The effective date of the exemption... monitoring and recording the concentration of reduced sulfur in flare gas. The owner or operator of...

  16. Operating a Microwave Radiation Detection Monitor. Module 10. Vocational Education Training in Environmental Health Sciences.

    Science.gov (United States)

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on operating a microwave radiation detection monitor. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) testing the…

  17. MONDO Project: real time ocean monitoring through Lagrangian drifters during offshore drilling operations

    Energy Technology Data Exchange (ETDEWEB)

    Mafra, Tatiana [Eni Oil do Brasil, Rio de Janeiro, RJ (Brazil); Fragoso, Mauricio da Rocha; Santos, Francisco Alves dos; Cruz, Leonardo M. Marques A.; Pellegrini, Julio A.C.; Cerrone, Bruna Nogueira [Prooceano, Rio de Janeiro, RJ (Brazil); Assireu, Arcilan Trevenzoli [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)

    2008-07-01

    Monitoring the ocean conditions during offshore operations is essential for both operational and environmental aspects. Environmentally, not only to know better the environment where the activity is taking place, but also to be able to provide fast and accurate response in case of accidents. MONDO Project (Monitoring by Ocean Drifters) is a pioneer initiative from ENI Oil do Brasil and PROOCEANO that aimed to monitor currents as a part of a metoceanographic data monitoring project of drilling operations in Brazilian Waters, in Santos Basin throughout September to November 2007, 40 satellite tracked ocean drifters were deployed will be transmitting data up to November 2008. The results of this project can be used to study a wide range of subjects about ocean dynamics. Following the principles of social and environmental responsibility, MONDO Project aims to benefit the local ecosystem in increasing the scientific knowledge of the area to calibrate hydrodynamic models that will lead to more accurate modeling results and, as a consequence, to a better management of contingency plans. Based on these principles, the project will also provide unrestricted access to oceanographic data even after the end of operations. (author)

  18. A Simulation Dashboard to Monitor Cognitive Workload during Dismounted Military Operations

    NARCIS (Netherlands)

    Beurden, M. van; Streefkerk, J.W.; Kamphuis, W.; Jetten, A.; Trijp, S. van; Venrooij, W.; Veldhuijs, G.

    2016-01-01

    The rapid development and adoption of new technologies (i.e. advanced sensor and communication platforms and monitoring devices) changes the way soldiers operate in the field. A concern frequently expressed by soldiers and commanders, is the increasing demand that technology places on the cognitive

  19. 40 CFR 63.9804 - What are my monitoring system installation, operation, and maintenance requirements?

    Science.gov (United States)

    2010-07-01

    ..., oxidation, and galvanic corrosion. (c) For each pressure CPMS that is used to monitor the pressure drop... where it is easily recognized by plant operating personnel. (6) For positive pressure fabric filter... pressure or induced air fabric filters, the bag leak detector must be installed downstream of the...

  20. 40 CFR 63.7188 - What are my monitoring installation, operation, and maintenance requirements?

    Science.gov (United States)

    2010-07-01

    ... Semiconductor Manufacturing Compliance Requirements § 63.7188 What are my monitoring installation, operation... emissions of your semiconductor process vent through a closed vent system to a control device, you must... evaluation procedure in § 63.7187(i) to demonstrate compliance, you must use the information from the...

  1. Visual evoked potentials monitoring in a case of transient post-operative visual loss

    Directory of Open Access Journals (Sweden)

    Marie Capon

    2016-01-01

    Full Text Available Post-operative visual loss (POVL is a rare, albeit potentially serious complication of general anaesthesia. This report describes the case of a 54-year-old woman who developed transient POVL after general anaesthesia following a left posterior parietal meningioma surgery in the prone position and discusses the usefulness of visual evoked potentials monitoring in such situations.

  2. Operational Monitoring of GOME-2 and IASI Level 1 Product Processing at EUMETSAT

    Science.gov (United States)

    Livschitz, Yakov; Munro, Rosemary; Lang, Rüdiger; Fiedler, Lars; Dyer, Richard; Eisinger, Michael

    2010-05-01

    The growing complexity of operational level 1 radiance products from Low Earth Orbiting (LEO) platforms like EUMETSATs Metop series makes near-real-time monitoring of product quality a challenging task. The main challenge is to provide a monitoring system which is flexible and robust enough to identify and to react to anomalies which may be previously unknown to the system, as well as to provide all means and parameters necessary in order to support efficient ad-hoc analysis of the incident. The operational monitoring system developed at EUMETSAT for monitoring of GOME-2 and IASI level 1 data allows to perform near-real-time monitoring of operational products and instrument's health in a robust and flexible fashion. For effective information management, the system is based on a relational database (Oracle). An Extract, Transform, Load (ETL) process transforms products in EUMETSAT Polar System (EPS) format into relational data structures. The identification of commonalities between products and instruments allows for a database structure design in such a way that different data can be analyzed using the same business intelligence functionality. An interactive analysis software implementing modern data mining techniques is also provided for a detailed look into the data. The system is effectively used for day-to-day monitoring, long-term reporting, instrument's degradation analysis as well as for ad-hoc queries in case of an unexpected instrument or processing behaviour. Having data from different sources on a single instrument and even from different instruments, platforms or numerical weather prediction within the same database allows effective cross-comparison and looking for correlated parameters. Automatic alarms raised by checking for deviation of certain parameters, for data losses and other events significantly reduce time, necessary to monitor the processing on a day-to-day basis.

  3. Monitoring historical masonry structures with operational modal analysis: Two case studies

    Science.gov (United States)

    Ramos, L. F.; Marques, L.; Lourenço, P. B.; De Roeck, G.; Campos-Costa, A.; Roque, J.

    2010-07-01

    The paper addresses two complex case studies of modal and structural identification of monuments in Portugal: the Clock Tower of Mogadouro and the Church of Jerónimos Monastery, in Lisbon. These are being monitored by University of Minho with vibration, temperature and relative air humidity sensors. Operational modal analysis is being used to estimate the modal parameters, followed by statistical analysis to evaluate the environmental effects on the dynamic response. The aim is to explore damage assessment in masonry structures at an early stage by vibration signatures, as a part of a health monitoring process that helps in the preservation of historical constructions. The paper presents the necessary preliminary dynamic analysis steps before the monitoring task, which includes installation of the monitoring system, system identification and subsequent FE model updating analysis, automatic modal identification and investigation of the influence of the environment on the identified modal parameters.

  4. Small Scale Irrigation Systems: A Training Manual. Planning--Construction--Operation and Maintenance of Small Scale Irrigation Systems. A Two-Week In-Service Training Program for Peace Corps Volunteers. Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-13.

    Science.gov (United States)

    Development Planning and Research Associates, Inc., Manhattan, KS.

    This manual provides materials for a two-week inservice training program for Peace Corps volunteers on the planning, construction, and operation and maintenance of small-scale irrigation systems. The workshop is designed to be given by two experienced professionals: one with practical knowledge of irrigation system design, operation, and…

  5. A review of market monitoring activities at U.S. independent system operators

    Energy Technology Data Exchange (ETDEWEB)

    Lesieutre, Bernard C.; Goldman, Charles; Bartholomew, Emily

    2004-01-01

    Policymakers have increasingly recognized the structural impediments to effective competition in electricity markets, which has resulted in a renewed emphasis on the need for careful market design and market monitoring in wholesale and retail electricity markets. In this study, we review the market monitoring activities of four Independent System Operators in the United States, focusing on such topics as the organization of an independent market monitoring unit (MMU), the role and value of external market monitors, performance metrics and indices to aid in market analysis, issues associated with access to confidential market data, and market mitigation and investigation authority. There is consensus across the four ISOs that market monitoring must be organizationally independent from market participants and that ISOs should have authority to apply some degree of corrective actions on the market, though scope and implementation differ across the ISOs. Likewise, current practices regarding access to confidential market data by state energy regulators varies somewhat by ISO. Drawing on our interviews and research, we present five examples that illustrate the impact and potential contribution of ISO market monitoring activities to enhance functioning of wholesale electricity markets. We also discuss several key policy and implementation issues that Western state policymakers and regulators should consider as market monitoring activities evolve in the West.

  6. Installation, maintenance and operating manual for the Lucas-type fuel injection system of the 3 B rotary engine

    Science.gov (United States)

    1985-01-01

    The installation procedure, maintenance, adjustment and operation of a Lucas type fuel injection system for 13B rotary racing engine is outlined. Components of the fuel injection system and installation procedure and notes are described. Maintenance, adjustment, and operation are discussed.

  7. Research of Zlin Z42 engine´s operation by EDM-800 monitoring system

    Directory of Open Access Journals (Sweden)

    Maria MRAZOVA

    2015-09-01

    Full Text Available The purpose of this paper is based on the analysis of the M137 engine performance by the EDM- 800 monitoring system that is also mounted on Zlin Z42 aircraft in operation of Air Training and Education Centre of the University of Zilina. This research consists of measurements based on the comparison and analysis of the engine parameters where its performance was simulated under various temperature conditions. Measured parameters are monitored during these flight regimes – take off, climb, cruise and approach. Briefly, these measurements are able to detect the existing problems during the engine operation and consequently they will be helpful to prevent potential engine malfunctions in the future operations.

  8. Integrating SAR with Optical and Thermal Remote Sensing for Operational Near Real-Time Volcano Monitoring

    Science.gov (United States)

    Meyer, F. J.; Webley, P.; Dehn, J.; Arko, S. A.; McAlpin, D. B.

    2013-12-01

    Volcanic eruptions are among the most significant hazards to human society, capable of triggering natural disasters on regional to global scales. In the last decade, remote sensing techniques have become established in operational forecasting, monitoring, and managing of volcanic hazards. Monitoring organizations, like the Alaska Volcano Observatory (AVO), are nowadays heavily relying on remote sensing data from a variety of optical and thermal sensors to provide time-critical hazard information. Despite the high utilization of these remote sensing data to detect and monitor volcanic eruptions, the presence of clouds and a dependence on solar illumination often limit their impact on decision making processes. Synthetic Aperture Radar (SAR) systems are widely believed to be superior to optical sensors in operational monitoring situations, due to the weather and illumination independence of their observations and the sensitivity of SAR to surface changes and deformation. Despite these benefits, the contributions of SAR to operational volcano monitoring have been limited in the past due to (1) high SAR data costs, (2) traditionally long data processing times, and (3) the low temporal sampling frequencies inherent to most SAR systems. In this study, we present improved data access, data processing, and data integration techniques that mitigate some of the above mentioned limitations and allow, for the first time, a meaningful integration of SAR into operational volcano monitoring systems. We will introduce a new database interface that was developed in cooperation with the Alaska Satellite Facility (ASF) and allows for rapid and seamless data access to all of ASF's SAR data holdings. We will also present processing techniques that improve the temporal frequency with which hazard-related products can be produced. These techniques take advantage of modern signal processing technology as well as new radiometric normalization schemes, both enabling the combination of

  9. Online Condition Monitoring to Enable Extended Operation of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Ryan M.; Bond, Leonard J.; Ramuhalli, Pradeep

    2012-03-31

    Safe, secure, and economic operation of nuclear power plants will remain of strategic significance. New and improved monitoring will likely have increased significance in the post-Fukushima world. Prior to Fukushima, many activities were already underway globally to facilitate operation of nuclear power plants beyond their initial licensing periods. Decisions to shut down a nuclear power plant are mostly driven by economic considerations. Online condition monitoring is a means to improve both the safety and economics of extending the operating lifetimes of nuclear power plants, enabling adoption of proactive aging management. With regard to active components (e.g., pumps, valves, motors, etc.), significant experience in other industries has been leveraged to build the science base to support adoption for online condition-based maintenance and proactive aging management in the nuclear industry. Many of the research needs are associated with enabling proactive management of aging in passive components (e.g., pipes, vessels, cables, containment structures, etc.). This paper provides an overview of online condition monitoring for the nuclear power industry with an emphasis on passive components. Following the overview, several technology/knowledge gaps are identified, which require addressing to facilitate widespread online condition monitoring of passive components.

  10. Digital monitoring and health diagnosis for mechanical equipment operation safety based on fiber Bragg grating sensor

    Institute of Scientific and Technical Information of China (English)

    Zude ZHOU; Desheng JIANG; Quan LIU

    2009-01-01

    This paper introduces fiber Bragg grating (FBG) based on a fiber optic grating sensor developed to be embedded on mechanical equipment for digital monitoring and health diagnosis. The theoretical and experimental researches on the new-style FBG sensor (FBGS) technology, high-speed demodulation, and data transmission are discussed. The transmission characteristics between the FBG and the detection interface, modeling and compensation method for online distributed multi-parameter digital monitoring and methods for data processing, synchronous sampling, and long-term dynamic digital monitoring using embedded technology are also presented. The acquired information by an FBGS can be used for the optimization of maintenance schedules and refinement of mechanical equipment design. It is a chal-lenge to gather real-time data from components working at high speed and in a severe environment of high temperature, high pressure, and high rotation speed. Currently, there are no sensors or technologies available for digital monitoring and health diagnosis under this rigorous situation for use in mechanical engineering operation safety. As a result, this paper introduces an online distributed and integrated digital monitoring system and health diagnosis. The new principle and new method will contribute to modem measurements in science and technology, mechanical engineering, and large mechanical equipment operation safety.

  11. Pre-operational monitor system of large inland lake water quality with MODIS imagery

    Science.gov (United States)

    Xiaoyu, Zhang; Dingtian, Yang; Xiaofeng, Zhang; Difeng, Wang; Shujing, Li; Delu, Pan

    2005-10-01

    EOS\\MODIS data have been proved a suitable and relative low-cost complementary tool to monitor large inland lake water quality for its re-visit frequency, moderate spatial and spectral resolution and appropriate channels designed for inversing water quality parameters. In this study, by the support of hi-tech research and development program of China, Lake water quality remote monitoring pre-operational system (LWQRMPS) was constructed aimed for practical monitoring of Taihu Lake water quality. The main water quality parameters including Chl-a and SPM, TN and TP inversion algorithm were developed. These parameters were obtained every month from time series fusion satellite data. With the routine trophic state evaluation system, the water quality was assessed every month based on the above retrieved MODIS water quality parameters, varied level of eutrophic area was computed. The obvious high reflectance in near-infrared spectrum caused by blue-green algal bloom support the application of 250m MODIS data in the algal bloom emergency monitor. Therefore, MODIS data were utilized successfully for inversing water quality parameters, evaluating eutrophication status, and detecting algal bloom in near real time. Standard thematic maps were produced and distributed to corresponding management departments. The accuracy of products and retrieve algorithm for operational use were tested with separate data sets. The result suggested that system is good enough for practical monitoring water quality of large size lakes and acquired identification.

  12. How field monitoring of green infrastructure stormwater practices has led to changes in North Carolina's Stormwater BMP design manual

    Science.gov (United States)

    Hunt, W. F.; Winston, R. J.

    2011-12-01

    Green Infrastructure stormwater management is comprised of many biologically-based stormwater treatment practices. Two of which, bioretention and level spreader- vegetative filter strips, have been extensively studied at over 10 different field locations across North Carolina by NC State University. The result of this research has been dramatic changes to the state of North Carolina's stormwater BMP Design Manual, which now allows a greater amount of flexibility for the design of each practice than most other design manuals. The purpose of this presentation is to present a summary of research conducted in North Carolina and associate that research with specific changes made in the state's design guidance for both bioretention (Table 1) and level spreader- vegetated filter strip systems (Table 2). Among the changes are type of vegetation, ratio of hydraulic loading, underdrainage configuration, and fill media selection. References (in print) associated with the tables are listed below: Hathaway, J.M. and W.F. Hunt. 2008. Field Evaluation of Level Spreaders in the Piedmont of North Carolina. Journal of Irrigation and Drainage Engineering, 134(4):538-542. Hunt, W.F., A.R. Jarrett, J.T. Smith, L.J. Sharkey. 2006. Evaluating Bioretention Hydrology and Nutrient Removal at Three Field Sites in North Carolina. Journal of Irrigation and Drainage Engineering, 132 (6): 600-608. Hunt, W.F., J.M. Hathaway, R.J. Winston, and S.J. Jadlocki. 2010. Runoff Volume Reduction by a Level Spreader - Vegetated Filter Strip System in Suburban Charlotte, NC. Journal of Hydrologic Engineering, 15(6): 399-503. Jones, M.P. and W.F. Hunt. 2009. Bioretention Impact on Runoff Temperature in Trout Sensitive Waters. Journal of Environmental Engineering, 135(8): 577-585. Li, H., L.J. Sharkey, W.F. Hunt, A.P. Davis. 2009. Mitigation of Impervious Surface Hydrology using Bioretention in North Carolina and Maryland. Journal of Hydrologic Engineering, 14(4): 407-415. Line, D.E. and W.F. Hunt. 2009

  13. Lessons learned from the introduction of autonomous monitoring to the EUVE science operations center

    Science.gov (United States)

    Lewis, M.; Girouard, F.; Kronberg, F.; Ringrose, P.; Abedini, A.; Biroscak, D.; Morgan, T.; Malina, R. F.

    1995-01-01

    The University of California at Berkeley's (UCB) Center for Extreme Ultraviolet Astrophysics (CEA), in conjunction with NASA's Ames Research Center (ARC), has implemented an autonomous monitoring system in the Extreme Ultraviolet Explorer (EUVE) science operations center (ESOC). The implementation was driven by a need to reduce operations costs and has allowed the ESOC to move from continuous, three-shift, human-tended monitoring of the science payload to a one-shift operation in which the off shifts are monitored by an autonomous anomaly detection system. This system includes Eworks, an artificial intelligence (AI) payload telemetry monitoring package based on RTworks, and Epage, an automatic paging system to notify ESOC personnel of detected anomalies. In this age of shrinking NASA budgets, the lessons learned on the EUVE project are useful to other NASA missions looking for ways to reduce their operations budgets. The process of knowledge capture, from the payload controllers for implementation in an expert system, is directly applicable to any mission considering a transition to autonomous monitoring in their control center. The collaboration with ARC demonstrates how a project with limited programming resources can expand the breadth of its goals without incurring the high cost of hiring additional, dedicated programmers. This dispersal of expertise across NASA centers allows future missions to easily access experts for collaborative efforts of their own. Even the criterion used to choose an expert system has widespread impacts on the implementation, including the completion time and the final cost. In this paper we discuss, from inception to completion, the areas where our experiences in moving from three shifts to one shift may offer insights for other NASA missions.

  14. Monitoring of peri-operative fluid administration by individualized goal-directed therapy

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M; Holte, Kathrine; Secher, N H;

    2007-01-01

    (n = 725) found a reduced hospital stay. Post-operative nausea and vomiting (PONV) and ileus were reduced in three studies and complications were reduced in four studies. Of the monitors that may be applied for goal-directed therapy, only oesophageal Doppler has been tested adequately; however......, several other options exist. CONCLUSION: Goal-directed therapy with the maximization of flow-related haemodynamic variables reduces hospital stay, PONV and complications, and facilitates faster gastrointestinal functional recovery. So far, oesophageal Doppler is recommended, but other monitors...

  15. Review of Portable, Manually Operated, and Non-Total Flooding Fire Extinguishing Technologies for Use on Naval Vessels

    Science.gov (United States)

    2011-12-01

    requires that the process be self -sustainable. An uninhibited chemical chain reason is necessary for this to happen. Portable fire extinguishers need...application of the inert gas be monitored or fire fighting personnel exposed to these gases (at the area of localized use) are equipped with self - contained...Halons for Aircraft Fire Suppression Systems—2011 Update” 2011-03-07. http://www.fire.tc.faa.gov/pdf/DraftHalonOptionsReport2011-03-15.pdf [58] Estee

  16. SULIVAN: Remote Manual Valve Monitoring System Real-Time Transmission of Valve Positions to Reduce Alignment Errors

    Energy Technology Data Exchange (ETDEWEB)

    Denis, J.C.; Mace, J.R.; Perisse, J.

    2015-07-01

    Every year, a number of plants worldwide face valve misalignment issues that can lead to damaged components and unplanned extended outage. By installing valve monitoring solutions, the plant can expect a reduction of the risk of valve misalignment events. Over the past years, AREVA has developed Wireless communication solutions and Smart sensor expertise at its own facilities and has carried out tests in nuclear power plants. This paper presents AREVA Wireless studies and Solutions that could be implemented in a nuclear plant. These solutions are mainly based on IoT technologies as MEMs and Low Power Wide Area Network, LPWAN. (Author)

  17. High prevalence of respiratory symptoms among workers in the development section of a manually operated coal mine in a developing country: A cross sectional study - article no. 17

    Energy Technology Data Exchange (ETDEWEB)

    Mamuya, S.H.D.; Bratveit, M.; Mashalla, Y.; Moen, B.E. [University of Bergen, Bergen (Norway). Center for International Health

    2007-02-15

    This study assesses the associations between exposure to dust and quartz and respiratory symptoms among coal mine workers in a manually operated coal mine in Tanzania, focusing on development workers, as they have the highest exposure to coal dust. A cross-sectional study was carried out among 250 production workers from a coal mine. Interviews were performed using modified standardized questionnaires to elicit information on occupational history, demographics, smoking habits and acute and chronic respiratory symptoms. The relationships between current dust exposure as well as cumulative respirable dust and quartz and symptoms were studied by group comparisons as well as logistic regression. The development workers in a coal mine had more acute and chronic respiratory symptoms than the mine and the other production workers. In addition, there was an association between high cumulative coal dust and respiratory symptoms.

  18. Resource Manual

    Science.gov (United States)

    Human Development Institute, 2008

    2008-01-01

    This manual was designed primarily for use by individuals with developmental disabilities and related conditions. The main focus of this manual is to provide easy-to-read information concerning available resources, and to provide immediate contact information for the purpose of applying for resources and/or locating additional information. The…

  19. CMS plotter graphics training manual

    Energy Technology Data Exchange (ETDEWEB)

    Cawby, R.D.

    1981-03-01

    This manual includes explanations of several graphics programs that use a Conversation Monitor System (CMS) terminal and a table-top plotter to produce a copy on bond paper or transparency film. 13 figures.

  20. First Operating Experiences of Beam Position Monitors in the TESLA Test Facility Linac

    Science.gov (United States)

    Lorenz, R.; Sachwitz, M.; Schreiber, H. J.; Tonisch, F.; Castellano, M.; Patteri, P.; Tazzioli, F.; Catani, L.

    1997-05-01

    Different types of monitors where installed in the TESLA Test Facility Linac to measure the beam position. At each superconducting quadrupole, the transverse beam position will be measured with a resolution of better than 10 μm, using a cylindrical cavity excited in the TM_110-mode by an off-center beam. In addition, two 'warm' cavities working at room temperature were built for the Injector I and the Bunch Compressor. The amplitude of the TM_110-mode and its phase are measured in a homodyne receiver. For the experimental area, stripline monitors having a resolution of better than 100 μm were built, tested and installed. The averaged position of the whole bunch train of Injector I is measured in a narrowband receiver using the amplitude-to-phase conversion. This paper summarizes the designs, cold tests and first operating experiences of both monitor types.

  1. Launch Complex 39A, SWMU 008, Operations, Maintenance, and Monitoring Report, Kennedy Space Center, FL

    Science.gov (United States)

    Wilson, Deborah M.

    2016-01-01

    This Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from Year 1 operation of the air sparging (AS) groundwater interim measure (IM) for High-Concentration Plumes (HCPs) and Low-Concentration Plumes (LCPs) within the perimeter fence line at Launch Complex 39A (LC39A) located at Kennedy Space Center (KSC), Florida. The objective of the LC39A groundwater IM is to actively decrease concentrations of trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), and vinyl chloride (VC) in groundwater in the HCP and LCP within the pad perimeter fence line via AS to levels less than Florida Department of Environmental Protection (FDEP) Groundwater Cleanup Target Levels (GCTLs). The objective was developed because LC39A is currently being leased to Space Exploration Technologies (SpaceX), and the original IM for monitored natural attenuation (MNA) over an extended period of time was not suitable for future planned site use.

  2. 3rd International Conference on Condition Monitoring of Machinery in Non-Stationary Operations

    CERN Document Server

    Rubini, Riccardo; D'Elia, Gianluca; Cocconcelli, Marco; Chaari, Fakher; Zimroz, Radoslaw; Bartelmus, Walter; Haddar, Mohamed

    2014-01-01

    This book presents the processings of the third edition of the Condition Monitoring of Machinery in Non-Stationary Operations (CMMNO13) which was held in Ferrara, Italy. This yearly event merges an international community of researchers who met – in 2011 in Wroclaw (Poland) and in 2012 in Hammamet (Tunisia) – to discuss issues of diagnostics of rotating machines operating in complex motion and/or load conditions. The growing interest of the industrial world on the topics covered by the CMMNO13 involves the fields of packaging, automotive, agricultural, mining, processing and wind machines in addition to that of the systems for data acquisition.The participation of speakers and visitors from industry makes the event an opportunity for immediate assessment of the potential applications of advanced methodologies for the signal analysis. Signals acquired from machines often contain contributions from several different components as well as noise. Therefore, the major challenge of condition monitoring is to po...

  3. Collaboration pathway(s) using new tools for optimizing operational climate monitoring from space

    Science.gov (United States)

    Helmuth, Douglas B.; Selva, Daniel; Dwyer, Morgan M.

    2014-10-01

    Consistently collecting the earth's climate signatures remains a priority for world governments and international scientific organizations. Architecting a solution requires transforming scientific missions into an optimized robust `operational' constellation that addresses the needs of decision makers, scientific investigators and global users for trusted data. The application of new tools offers pathways for global architecture collaboration. Recent (2014) rulebased decision engine modeling runs that targeted optimizing the intended NPOESS architecture, becomes a surrogate for global operational climate monitoring architecture(s). This rule-based systems tools provide valuable insight for Global climate architectures, through the comparison and evaluation of alternatives considered and the exhaustive range of trade space explored. A representative optimization of Global ECV's (essential climate variables) climate monitoring architecture(s) is explored and described in some detail with thoughts on appropriate rule-based valuations. The optimization tools(s) suggest and support global collaboration pathways and hopefully elicit responses from the audience and climate science shareholders.

  4. Mathematical model and algorithm of operation scheduling for monitoring situation in local waters

    Directory of Open Access Journals (Sweden)

    Sokolov Boris

    2017-01-01

    Full Text Available A multiple-model approach to description and investigation of control processes in regional maritime security system is presented. The processes considered in this paper were qualified as control processes of computing operations providing monitoring of the situation adding in the local water area and connected to relocation of different ships classes (further the active mobile objects (AMO. Previously developed concept of active moving object (AMO is used. The models describe operation of AMO automated monitoring and control system (AMCS elements as well as their interaction with objects-in-service that are sources or recipients of information being processed. The unified description of various control processes allows synthesizing simultaneously both technical and functional structures of AMO AMCS. The algorithm for solving the scheduling problem is described in terms of the classical theory of optimal automatic control.

  5. The Research on the Construction of Monitoring and Evaluation System for the Operation of Marine Economy in Liaoning Province

    Institute of Scientific and Technical Information of China (English)

    Qianjin; TAN; Weimin; GOU; Peili; SUN

    2015-01-01

    According to the needs of Liaoning province marine economic operation monitoring and evaluation system for capacity building in this paper,it proposes the concept of marine economy operation monitoring and evaluation system,and introduces the system construction content and its architecture,and discusses the key issues on the monitoring index system,evaluation index system,mechanism construction and system implementation. It will help to improve the Liaoning marine economic statistical informatization level and promote the innovation of marine economy in Liaoning,and expect to provide reference for the system construction of other coastal provinces’ provincial marine economy operation monitoring and evaluation system.

  6. Impact of operational factors on fossil energy inputs in motor-manual tree felling and processing: results of two case studies

    Directory of Open Access Journals (Sweden)

    Gheorghe Ignea

    2017-07-01

    Full Text Available In many cases tree felling and processing operations are carried out motor-manually and knowledge about fossil fuel consumption and direct energy inputs when using such equipment is required for different purposes starting with operational costing and ending with environmental assessment of forest operations. In this study, fuel mixture, chain oil and direct fossil energy inputs were evaluated for two chainsaws which were used to fell and process trees in two silvicultural systems. The results of this study suggest that there is a strong dependence relation between selected tree size variables such as the diameter at breast height and tree volume on one hand and the fuel mixture, chain oil and direct fossil energy inputs when felling and processing broadleaved hardwood and resinous softwood trees on the other hand. For the broadleaved trees (mean tree volume of 1.50 m3 × tree-1, DBH of 45.5 cm and tree height of 21.84 m the mean direct fossil energy input was of 3.86 MJ m-3 while for resinous trees (mean tree volume of 1.77 m3 tree-1, DBH of 39.28 cm and tree height of 32.49 m it was of 3.93 MJ m-3. Other variables, including but not limited to the technology used, work experience and procedural pattern, may influence the mentioned figures and extensive studies are required to clarify their effects.

  7. Post operative capnostream monitoring in patients with obstructive sleep apnoea symptoms – Case series

    Directory of Open Access Journals (Sweden)

    Vasanth Rao Kadam

    2016-07-01

    Full Text Available Obstructive sleep apnoea (OSA patients on opioid analgesic have an increased incidence of postoperative respiratory complications; prevention of these may be possible with appropriate post-operative monitoring. We recruited 4 OSA patients who had general anaesthesia for orthopaedic and septoplasty surgery. They required Patient Controlled Analgesia (PCA or oral opioids in the post-operative period, hence continuous Saturation of Oxygen (Spo2, End Tidal Carbon dioxide (EtCo2 monitoring on Capnostream monitor with Integrated Pulmonary Index (IPI was organized in high dependency unit. Overnight data was collected every 30 s which included pulse rate, respiratory rate, EtCo2, Spo2, and IPI. The nursing staff was also asked to document if any intervention was carried out due to altered IPI. For first two patient events occurred during various hours but there were no significant events in early night even though increased opioid use at that time. During the period of desaturation nurse intervention required to increase the O2 flow in the first patient but corrected spontaneously in the second patient. IPI index improved over a period of 2 min in most of the events. The duration of desaturation did not correspond with the IPI in only once, remaining period the clinical symptoms were consistent with fall in O2 saturation. The microstream capnography with IPI may provide complete respiratory status of the patient because of its comprehensive parameters on one screen. Main limitation was duration of monitoring was limited to overnight. Capnostream monitoring with IPI may have a role in patients monitoring with OSA on PCA in the postoperative ward but more trials are necessary.

  8. 14 CFR 135.21 - Manual requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Manual requirements. 135.21 Section 135.21... AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 135.21 Manual... operations, shall prepare and keep current a manual setting forth the certificate holder's procedures...

  9. 33 CFR 157.49 - Instruction manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Instruction manual. 157.49... Vessel Operation § 157.49 Instruction manual. The master of a tank vessel shall ensure that the instruction manual under § 157.23 is available and used when the cargo or ballast systems are operated....

  10. Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating

    Science.gov (United States)

    Casada, Donald A.

    1996-01-01

    A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization.

  11. Use of intellectual sensor technics for monitoring and search-and-rescue operations

    OpenAIRE

    Гурник, Анатолій Васильович; Валуйський, Станіслав Вікторович

    2013-01-01

    The article studies methods for improving the organization of search and rescue operations involving aviation search and rescue facilities using sensor networks, monitoring-signal sensing and geographic information technologies. When collecting information from remote sensors with a single unmanned aerial vehicle (UAV), it is necessary to search for such a UAV flight path, which will enable to read data from all the sensors minimizing the total distance traveled and fuel consumption of the UA...

  12. Radar and ARPA manual

    CERN Document Server

    Bole, A G

    2013-01-01

    Radar and ARPA Manual focuses on the theoretical and practical aspects of electronic navigation. The manual first discusses basic radar principles, including principles of range and bearing measurements and picture orientation and presentation. The text then looks at the operational principles of radar systems. Function of units; aerial, receiver, and display principles; transmitter principles; and sitting of units on board ships are discussed. The book also describes target detection, Automatic Radar Plotting Aids (ARPA), and operational controls of radar systems, and then discusses radar plo

  13. Modification and Continue Monitoring of Kartini Reactor Tank Liner for Long Term Safe Operation

    Energy Technology Data Exchange (ETDEWEB)

    Puradwi, I. W.; Nitiswati, S.; Tjiptono, T.; Umar, S.; Nugroho, Tri [BATAN, Yogyakarta (Indonesia)

    2013-07-01

    This paper discusses an experience on modification of bulk shielding facility (BSF) and monitoring of the Kartini reactor tank liner through in-service inspection (ISI) for long term safe operation. The objective of BSF modification is to prevent future water penetration from BSF to both the thermalizing column and space between the aluminium reactor tank liner and the concrete. Modification of BSF needs to be conducted because leakage from the BSF has entered to the area behind the aluminium tank liner and has saturated the concrete that has potential to corrode the steel reinforcement bar, and subsequently pushing the aluminium bottom tank and causing the swelling. The three swelling on the bottom tank have been continued monitoring through ISI regularly since 2001 up to now to observe and measure the three swellings profile. Result of swellings profile measurement indicated that swelling had grown slowly in size and became relatively stable. Careful analysis and assessment of the root causes of the swelling indicated that swelling do not present a threat to future safe operation of the reactor and Kartini reactor is considered to be in good condition. As an outcome of modification and continue monitoring, Kartini Reactor in Yogyakarta has been already obtained extended operation license for the third period from Nuclear Energy Regulatory Agency of Indonesia (BAPETEN) up to 2020.

  14. Haemodynamic monitoring in the peri-operative period: the past, the present and the future.

    Science.gov (United States)

    Watson, X; Cecconi, M

    2017-01-01

    Over recent years there has been an increase in the implementation of goal-directed therapy using minimally invasive haemodynamic monitoring techniques to guide peri-operative care. Since the introduction of the pulmonary artery flotation catheter in the 1980s, various haemodynamic monitors have been developed, each associated with their own benefits and limitations. Goal-directed therapy has been well-established as a standard of care in the peri-operative period and has largely been associated with a reduction in morbidity and mortality. However, evidence over the last few years from major studies has led us to question: what is the future for goal-directed therapy? Care of the peri-operative patient has significantly evolved over the last decade and this needs to be taken into account when assessing the results of these studies. We should therefore not look at the effects of goal-directed therapy in isolation but as part of a progressive care bundle. Additionally, other markers of haemodynamic status have also begun to be further appreciated and these are worthy of further investigation. We feel that the future for haemodynamic monitoring remains promising with new areas of interest continuously emerging, but further research is still required. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  15. Distributed Monitoring for Prevention of Cascading Failures in Operational Power Grids

    CERN Document Server

    Warnier, Martijn; Koç, Yakup; Pauwels, Eric

    2015-01-01

    Electrical power grids are vulnerable to cascading failures that can lead to large blackouts. Detection and prevention of cascading failures in power grids is impor- tant. Currently, grid operators mainly monitor the state (loading level) of individual components in power grids. The complex architecture of power grids, with many interdependencies, makes it difficult to aggregate data provided by local compo- nents in a timely manner and meaningful way: monitoring the resilience with re- spect to cascading failures of an operational power grid is a challenge. This paper addresses this challenge. The main ideas behind the paper are that (i) a robustness metric based on both the topology and the operative state of the power grid can be used to quantify power grid robustness and (ii) a new proposed a distributed computation method with self-stabilizing properties can be used to achieving near real-time monitoring of the robustness of the power grid. Our con- tributions thus provide insight into the resilience wit...

  16. Operator’s Manual for UH-60A Helicopter, UH-60L Helicopter, EH-60A Helicopter

    Science.gov (United States)

    2007-11-02

    chief seating, troop seating, litter installation and cargo. Restraint of cargo is by tiedown rings installed in the floor. Two stowage compartments, at... rack mounts and seats. Blackout curtains may be used to eliminate any light intrusion into the cockpit during night operations, or any glare on the...24 CH EC K L IST ST OW AG E DA TA & MA P CHECK LIST DATA & MAP STOWAGE 1. UPPER CONSOLE 2. PILOT’S COCKPIT UTILITY LIGHT 3. FREE−AIR TEMPERATURE

  17. Keepers of the "CAN’T Manual": The Role of Financial Managers in Joint Operations

    Science.gov (United States)

    2007-05-10

    MSEL Title: Preparations for Bird Flu Training Objective: To make a plan or order that reflects the concept and intent of the geographic combatant...Description: Early indications of the spread of Bird Flu in the north have increased the CTF commanders concern that if the Bird Flu turns into a pandemic...that operations in the south will be disrupted. The CTF commander has tasked the staff to begin planning for protecting CTF forces from the Bird Flu . Resources

  18. Supply Warehouse#3, SWMU 088 Operations, Maintenance, and Monitoring Report Kennedy Space Center, Florida

    Science.gov (United States)

    Murphy, Alex

    2016-01-01

    This document presents the findings, observations, and results associated with Operations, Maintenance, and Monitoring (OM&M) activities of Corrective Measures Implementation (CMI) activities conducted at Supply Warehouse #3 (SW3) located at John F. Kennedy Space Center (KSC), Florida from October 8, 2015, to September 12, 2016, and performance monitoring results for semi-annual sampling events conducted in March and September 2016. The primary objective of SW3 CMI is to actively decrease concentrations of trichloroethene (TCE) and vinyl chloride (VC) to less than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs), and the secondary objective is to reduce TCE, cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE), 1,1-dichloroethene (11DCE), and VC concentrations to less than FDEP Groundwater Cleanup Target Levels (GCTLs). The SW3 facility has been designated Solid Waste Management Unit (SWMU) 088 under KSC's Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Based on the results to date, the SW3 air sparging (AS) system is operating at or below the performance criteria as presented in the 2008 SW3 Corrective Measures Implementation (CMI) Work Plan and 2009 and 2012 CMI Work Plan Addenda. Since the start of AS system operations on December 19, 2012, through the September 2016 groundwater sampling event, TCE concentrations have decreased to less than the GCTL in all wells within the Active Remediation Zone (ARZ), and VC results remain less than NADC but greater than GCTL. Based on these results, team consensus was reached at the October 2016 KSC Remediation Team (KSCRT) meeting to continue AS system operations and semi-annual performance monitoring of volatile organic compounds in March 2017 at ten monitoring wells at select locations, and in September 2017 at four monitoring wells at select locations to reduce VC concentrations to below GCTL. Additionally, surface water samples

  19. TEG BASED POWER SYSTEM for OPERATION of HEALTH MONITORING SERVER in INDUSTRIES

    Directory of Open Access Journals (Sweden)

    P.S.Raghavendran

    2014-01-01

    Full Text Available In Hazardous environment industries where the emission of toxic gases and effluents will have an impact on the health of the operators, the recording of health parameters of individual operators is very important. In such situation the health monitoring of operators are being monitored and processed centrally by a server and this can be powered by a system of batteries which can be operated from TEG to ensure reliability and to utilize the exhaust heat energy of industries for better performance. This paper describes the Thermo electric generator with battery that supports medical server. The thermoelectric generator converts heat energy into electrical energy. Mathematical model of thermoelectric generator was developed in MATLAB SIMULINK. This exhibits different voltage and current for various temperature differences. The proposed system uses maximum power point tracking algorithm to obtain the maximum power from the thermoelectric generator. This algorithm is developed in embedded MATLAB controller, which gives the firing angle to the DC-DC Boost converter for various temperature differences. This will increase the efficiency of the system.

  20. Incorporating voltage security into the planning, operation and monitoring of restructured electric energy markets

    Science.gov (United States)

    Nair, Nirmal-Kumar

    As open access market principles are applied to power systems, significant changes are happening in their planning, operation and control. In the emerging marketplace, systems are operating under higher loading conditions as markets focus greater attention to operating costs than stability and security margins. Since operating stability is a basic requirement for any power system, there is need for newer tools to ensure stability and security margins being strictly enforced in the competitive marketplace. This dissertation investigates issues associated with incorporating voltage security into the unbundled operating environment of electricity markets. It includes addressing voltage security in the monitoring, operational and planning horizons of restructured power system. This dissertation presents a new decomposition procedure to estimate voltage security usage by transactions. The procedure follows physical law and uses an index that can be monitored knowing the state of the system. The expression derived is based on composite market coordination models that have both PoolCo and OpCo transactions, in a shared stressed transmission grid. Our procedure is able to equitably distinguish the impacts of individual transactions on voltage stability, at load buses, in a simple and fast manner. This dissertation formulates a new voltage stability constrained optimal power flow (VSCOPF) using a simple voltage security index. In modern planning, composite power system reliability analysis that encompasses both adequacy and security issues is being developed. We have illustrated the applicability of our VSCOPF into composite reliability analysis. This dissertation also delves into the various applications of voltage security index. Increasingly, FACT devices are being used in restructured markets to mitigate a variety of operational problems. Their control effects on voltage security would be demonstrated using our VSCOPF procedure. Further, this dissertation investigates

  1. Work flow with manual re-registration of cardiac 18F-FDG PET and attenuation correction CT to compensate for respiratory motion: Effects and inter-operator variability

    DEFF Research Database (Denmark)

    Juhl, Christian; Christensen, Nana Louise; Møller, Lone W.;

    observed in 15 % (6/40) of the scans, and, as expected, mainly in lateral segments. It was estimated that 80% (5/6) of these artefacts could be reduced using manual re-registration procedure. This is in agreement with previous reports1-3. The inter-operator variability was generally low, except in a few......-registration is currently the most feasible. In this study, we examine both the effect on misalignment artefacts and the inter-operator variability of manual re-registration performed by the technologist in a step before the final image reconstruction and verified by a second technologist before image analysis. Method: 40...... 18F-FDG viability scans were examined. After the patient scan, a fast image reconstruction of low quality was made and used for manual re-registration of PET and AC CT, before starting the high quality reconstruction used for analysis. The left ventricle was reoriented and segmented in QPS (Cedar...

  2. Autonomy and manual operation in a small robotic system for under-vehicle inspections at security checkpoints

    Science.gov (United States)

    Smuda, William; Muench, Paul L.; Gerhart, Grant R.; Moore, Kevin L.

    2002-07-01

    Unmanned ground vehicle (UGV) technology can be used in a number of ways to assist in counter-terrorism activities. In addition to the conventional uses of tele-operated robots for unexploded ordinance handling and disposal, water cannons and other crowd control devices, robots can also be employed for a host of terrorism deterrence and detection applications. In previous research USU developed a completely autonomous prototype robot for performing under- vehicle inspections in parking areas (ODIS). Testing of this prototype and discussions with the user community indicated that neither the technology nor the users are ready for complete autonomy. In this paper we present a robotic system based on ODIS that balances the users' desire/need for tele- operation with a limited level of autonomy that enhances the performance of the robot. The system can be used by both civilian law enforcement and military police to replace the traditional mirror on a stick system of looking under cars for bombs and contraband.

  3. 污染源在线监测及运营管理存在的问题分析%Analysis on the Problems of Online Monitoring and Operation Management for Pollution Sources

    Institute of Scientific and Technical Information of China (English)

    黄福波; 王日东; 徐辉

    2012-01-01

    结合大连市污染源在线监测系统建设实例,介绍了固定污染源在线监测组成及其分析仪器设备运行管理方式;通过在线监测与手工检测数据比对,验证在线监测的可行性;研究系统在建设和实际运行中存在的监测条件和环境不规范及在线监测数据传输的不稳定性等问题提出改进意见,为环境保护的自动化污染源监测全面实施起到借鉴作用.%Combing with the instance of establishing pollution sources online monitoring system,the components of online monitoring and operation management mode of analytical instrument for fixed pollution sources were introduced. By data comparison of online monitoring and manual testing,the feasibility of online monitoring was verified. The main problems,such as nonstandard of monitoring condition and environment,and instability of online monitoring data transmission,in construction and operation were studied any improvement suggestions were put forward to provide reference for implementation of automatic pollution sources monitoring.

  4. Operational Reliability Assessment of Compressor Gearboxes with Normalized Lifting Wavelet Entropy from Condition Monitoring Information

    Directory of Open Access Journals (Sweden)

    Xiaoli Zhang

    2015-05-01

    Full Text Available Classical reliability assessment methods have predominantly focused on probability and statistical theories, which are insufficient in assessing the operational reliability of individual mechanical equipment with time-varying characteristics. A new approach to assess machinery operational reliability with normalized lifting wavelet entropy from condition monitoring information is proposed, which is different from classical reliability assessment methods depending on probability and statistics analysis. The machinery vibration signals with time-varying operational characteristics are firstly decomposed and reconstructed by means of a lifting wavelet package transform. The relative energy of every reconstructed signal is computed as an energy percentage of the reconstructed signal in the whole signal energy. Moreover, a normalized lifting wavelet entropy is defined by the relative energy to reveal the machinery operational uncertainty. Finally, operational reliability degree is defined by the quantitative value obtained by the normalized lifting wavelet entropy belonging to the range of [0, 1]. The proposed method is applied in the operational reliability assessment of the gearbox in an oxy-generator compressor to validate the effectiveness.

  5. Activated Sludge Process Workshop Manual.

    Science.gov (United States)

    Ontario Ministry of the Environment, Toronto.

    This manual was developed for use at workshops designed to upgrade the knowledge of experienced wastewater treatment plant operators. Each of the lessons in this document has clearly stated behavioral objectives to tell the trainee what he should know or do after completing that topic. Areas covered in this manual include: types and factors…

  6. Surface Water Treatment Workshop Manual.

    Science.gov (United States)

    Ontario Ministry of the Environment, Toronto.

    This manual was developed for use at workshops designed to increase the knowledge of experienced water treatment plant operators. Each of the fourteen lessons in this document has clearly stated behavioral objectives to tell the trainee what he should know or do after completing that topic. Areas covered in this manual include: basic water…

  7. 40 CFR Appendix K to Part 75 - Quality Assurance and Operating Procedures for Sorbent Trap Monitoring Systems

    Science.gov (United States)

    2010-07-01

    ... Pump. Use a leak-tight, vacuum pump capable of operating within the candidate system's flow range. 5.1... sorbent trap monitoring system typically operates. The gas flow meter shall be equipped with any necessary... system typically operates. You may either follow the procedures in section 10.3.1 of Method 5 in...

  8. A sensor management architecture concept for monitoring emissions from open-air demil operations.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Michael M.; Robinson, Jerry D.; Stoddard, Mary Clare; Horn, Brent A.; Lipkin, Joel; Foltz, Greg W.

    2005-09-01

    Sandia National Laboratories, CA proposed a sensor concept to detect emissions from open-burning/open-detonation (OB/OD) events. The system would serve two purposes: (1) Provide data to demilitarization operations about process efficiency, allowing process optimization for cleaner emissions and higher efficiency. (2) Provide data to regulators and neighboring communities about materials dispersing into the environment by OB/OD operations. The proposed sensor system uses instrument control hardware and data visualization software developed at Sandia National Laboratories to link together an array of sensors to monitor emissions from OB/OD events. The suite of sensors would consist of various physical and chemical detectors mounted on stationary or mobile platforms. The individual sensors would be wirelessly linked to one another and controlled through a central command center. Real-time data collection from the sensors, combined with integrated visualization of the data at the command center, would allow for feedback to the sensors to alter operational conditions to adjust for changing needs (i.e., moving plume position, increased spatial resolution, increased sensitivity). This report presents a systems study of the problem of implementing a sensor system for monitoring OB/OD emissions. The goal of this study was to gain a fuller understanding of the political, economic, and technical issues for developing and fielding this technology.

  9. Application-Ready Expedited MODIS Data for Operational Land Surface Monitoring of Vegetation Condition

    Directory of Open Access Journals (Sweden)

    Jesslyn F. Brown

    2015-12-01

    Full Text Available Monitoring systems benefit from high temporal frequency image data collected from the Moderate Resolution Imaging Spectroradiometer (MODIS system. Because of near-daily global coverage, MODIS data are beneficial to applications that require timely information about vegetation condition related to drought, flooding, or fire danger. Rapid satellite data streams in operational applications have clear benefits for monitoring vegetation, especially when information can be delivered as fast as changing surface conditions. An “expedited” processing system called “eMODIS” operated by the U.S. Geological Survey provides rapid MODIS surface reflectance data to operational applications in less than 24 h offering tailored, consistently-processed information products that complement standard MODIS products. We assessed eMODIS quality and consistency by comparing to standard MODIS data. Only land data with known high quality were analyzed in a central U.S. study area. When compared to standard MODIS (MOD/MYD09Q1, the eMODIS Normalized Difference Vegetation Index (NDVI maintained a strong, significant relationship to standard MODIS NDVI, whether from morning (Terra or afternoon (Aqua orbits. The Aqua eMODIS data were more prone to noise than the Terra data, likely due to differences in the internal cloud mask used in MOD/MYD09Q1 or compositing rules. Post-processing temporal smoothing decreased noise in eMODIS data.

  10. Remote Operating Monitoring Of Spatial Stability Magnets On A Kurchatov Source Of Synchrotron Radiation

    CERN Document Server

    Barkovsky, E V; Martynenko, V V; Novikov, V A; Udin, L I

    2004-01-01

    During operation of the accelerator because of a nonuniform warm -up of the ring base and constructions of installation there are angular and linear displacements of bending and focusing magnets of a Big Accelerator Ring (BR) of a Kurchatov Source of Synchrotron Radiation. With the purpose of remote operating monitoring of a spatial position of elements BR was used anglemetrical control and measuring system with digital and analog registration in a real time mode. The results of the first stage of a monitoring BR have shown high informativity of the given instrumental - methodical means. The basic radiants of cyclical thermoelastic alternating strains are detected; the amplitudes of angular and linear displacements of magnets from different internal factors evaluated during operation of the accelerator. Is established, that the maximum radial angular and linear displacements of magnets are watched in 3,5-4 day after switching on of installation and achieve in max 30-35 seconds of an arc or 120-150 microns in ...

  11. Westinghouse Hanford Company operational environmental monitoring annual report, calendar year 1994

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, J.; Fassett, J.W.; Johnson, A.R.; Johnson, V.G.; Markes, B.M.; McKinney, S.M.; Moss, K.J.; Perkins, C.J.; Richterich, L.R.

    1995-08-01

    This document presents the results of the Westinghouse Hanford Company near-facility operational environmental monitoring for 1994 in the 100, 200/600, and 300/400 Areas of the Hanford Site, in south-central Washington State. Surveillance activities included sampling and analyses of ambient air surface water, groundwater, soil, sediments, and biota. Also, external radiation measurements and radiological surveys were taken at waste disposal sites, radiologically controlled areas, and roads. These activities were conducted to assess and control the effects of nuclear facilities and waste sites on the local environment. In addition, diffuse sources were monitored to determine compliance with Federal, State, and/or local regulations. In general, although effects from nuclear facilities are still seen on the Hanford Site and radiation levels are slightly elevated when compared to offsite locations, the differences are less than in previous years.

  12. Westinghouse Hanford Company operational environmental monitoring annual report - calendar year 1995

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, J.W., Westinghouse Hanford

    1996-07-30

    This document summarizes the results of the Westinghouse Hanford Company (WHC) near-facility operational environmental monitoring for 1995 in the 100, 200/600, and 300/400 Areas of the Hanford Site, in south-central Washington State. Surveillance activities included sampling and analyses of ambient air, surface water,groundwater, soil, sediments, and biota. Also, external radiation measurements and radiological surveys were taken at waste disposal sites, radiologically controlled areas, and roads. These activities were conducted to assess and control the effects of nuclear facilities and waste sites on the local environment. In addition, diffuse sources were monitored to determine compliance with Federal, State, and/or local regulations. In general, although effects from nuclear facilities can still be observed on the Hanford Site and radiation levels are slightly elevated when compared to offsite locations, the differences are less than in previous years.

  13. Interaction design challenges and solutions for ALMA operations monitoring and control

    Science.gov (United States)

    Pietriga, Emmanuel; Cubaud, Pierre; Schwarz, Joseph; Primet, Romain; Schilling, Marcus; Barkats, Denis; Barrios, Emilio; Vila Vilaro, Baltasar

    2012-09-01

    The ALMA radio-telescope, currently under construction in northern Chile, is a very advanced instrument that presents numerous challenges. From a software perspective, one critical issue is the design of graphical user interfaces for operations monitoring and control that scale to the complexity of the system and to the massive amounts of data users are faced with. Early experience operating the telescope with only a few antennas has shown that conventional user interface technologies are not adequate in this context. They consume too much screen real-estate, require many unnecessary interactions to access relevant information, and fail to provide operators and astronomers with a clear mental map of the instrument. They increase extraneous cognitive load, impeding tasks that call for quick diagnosis and action. To address this challenge, the ALMA software division adopted a user-centered design approach. For the last two years, astronomers, operators, software engineers and human-computer interaction researchers have been involved in participatory design workshops, with the aim of designing better user interfaces based on state-of-the-art visualization techniques. This paper describes the process that led to the development of those interface components and to a proposal for the science and operations console setup: brainstorming sessions, rapid prototyping, joint implementation work involving software engineers and human-computer interaction researchers, feedback collection from a broader range of users, further iterations and testing.

  14. Radiation monitoring data of the HTTR rise-to-power test. Results up to 30 MW operation on the rated operation mode

    Energy Technology Data Exchange (ETDEWEB)

    Ashikagaya, Yoshinobu; Yoshino, Toshiaki; Yasu, Katsuji; Sawa, Kazuhiro [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Kurosawa, Yoshiaki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2002-12-01

    The High Temperature Engineering Test Reactor (HTTR) have completed the Rise-to-Power test of 9 MW (the single and parallel loaded operation) in the rated operation mode, the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW (the single and parallel loaded operation). After that the Rise-to-Power test in the rated operation mode (the reactor outlet coolant temperature of 850degC) with a thermal output of 30 MW (the single and parallel loaded operation) were performed between October 20, 2001 and March 11, 2002. This report describes the radiation monitoring data carried out during the HTTR Rise-to-Power test in the rated operation mode with a thermal output of 30 MW. The dose equivalent rate the radioactive air concentration in the working place where the radiation workers enter during the reactor operation were respectively the back ground level and the lower detection limit. There were no release of the radioactive gaseous effluents to the environment through the stack. These radiation monitoring showed clearly the radiation level were very low. This report also describes the part of radiation monitoring data in the HTTR first cycle operation carried out during July 6, 2002 from March 20, 2002. (author)

  15. Radiation monitoring data of the HTTR rise-to-power test. Results up to 30 MW operation on the rated operation mode

    Energy Technology Data Exchange (ETDEWEB)

    Ashikagaya, Yoshinobu; Yoshino, Toshiaki; Yasu, Katsuji; Sawa, Kazuhiro [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Kurosawa, Yoshiaki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2002-12-01

    The High Temperature Engineering Test Reactor (HTTR) have completed the Rise-to-Power test of 9 MW (the single and parallel loaded operation) in the rated operation mode, the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW (the single and parallel loaded operation). After that the Rise-to-Power test in the rated operation mode (the reactor outlet coolant temperature of 850degC) with a thermal output of 30 MW (the single and parallel loaded operation) were performed between October 20, 2001 and March 11, 2002. This report describes the radiation monitoring data carried out during the HTTR Rise-to-Power test in the rated operation mode with a thermal output of 30 MW. The dose equivalent rate the radioactive air concentration in the working place where the radiation workers enter during the reactor operation were respectively the back ground level and the lower detection limit. There were no release of the radioactive gaseous effluents to the environment through the stack. These radiation monitoring showed clearly the radiation level were very low. This report also describes the part of radiation monitoring data in the HTTR first cycle operation carried out during July 6, 2002 from March 20, 2002. (author)

  16. An integrated approach to monitoring the calibration stability of operational dual-polarization radars

    Science.gov (United States)

    Vaccarono, Mattia; Bechini, Renzo; Chandrasekar, Chandra V.; Cremonini, Roberto; Cassardo, Claudio

    2016-11-01

    The stability of weather radar calibration is a mandatory aspect for quantitative applications, such as rainfall estimation, short-term weather prediction and initialization of numerical atmospheric and hydrological models. Over the years, calibration monitoring techniques based on external sources have been developed, specifically calibration using the Sun and calibration based on ground clutter returns. In this paper, these two techniques are integrated and complemented with a self-consistency procedure and an intercalibration technique. The aim of the integrated approach is to implement a robust method for online monitoring, able to detect significant changes in the radar calibration. The physical consistency of polarimetric radar observables is exploited using the self-consistency approach, based on the expected correspondence between dual-polarization power and phase measurements in rain. This technique allows a reference absolute value to be provided for the radar calibration, from which eventual deviations may be detected using the other procedures. In particular, the ground clutter calibration is implemented on both polarization channels (horizontal and vertical) for each radar scan, allowing the polarimetric variables to be monitored and hardware failures to promptly be recognized. The Sun calibration allows monitoring the calibration and sensitivity of the radar receiver, in addition to the antenna pointing accuracy. It is applied using observations collected during the standard operational scans but requires long integration times (several days) in order to accumulate a sufficient amount of useful data. Finally, an intercalibration technique is developed and performed to compare colocated measurements collected in rain by two radars in overlapping regions. The integrated approach is performed on the C-band weather radar network in northwestern Italy, during July-October 2014. The set of methods considered appears suitable to establish an online tool to

  17. Monitoring of IOR/EOR operations by electrical prospecting; Denki tansaho ni yoru IOR/EOR monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ushijima, K.; Mizunaga, H.; Ikeda, H.; Masuda, K. [Kyushu University, Fukuoka (Japan). Faculty of Engineering

    1996-10-01

    Fluid flow tomography (FFT) was developed to monitor enhanced oil recovery IOR/EOR operations. This method uses a casing pipe as linear current source by connecting a current electrode with a well inlet, and the other electrode is grounded at a point far different from the well. Potentials are rapidly measured at the same time by multi-channel receiving electrodes installed on the ground to obtain time series data composed of charged potential and superimposed spontaneous potential. After separation of both potentials, the charged potential data are processed by the conventional mise-a-la-masse method to extract local anomaly, determine the residual distribution and relative change distribution of time-sliced apparent resistivity, and obtain the 3-D profile of fluid. The spontaneous potential is also processed to obtain the deflection distribution of time-sliced potential at a specific time. Quantitative 3-D interpretation is conducted focusing attention on the generation mechanism of spontaneous potential. Behavior of underground permeated flow is determined as time series animation images to image fluid direction. This method was effective in real fields. 8 refs., 4 figs.

  18. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  19. Software systems for operation, control, and monitoring of the EBEX instrument

    CERN Document Server

    Milligan, Michael; Aubin, François; Baccigalupi, Carlo; Bao, Chaoyun; Borrill, Julian; Cantalupo, Christopher; Chapman, Daniel; Didier, Joy; Dobbs, Matt; Grainger, Will; Hanany, Shaul; Hillbrand, Seth; Hubmayr, Johannes; Jaffe, Andrew; Johnson, Bradley; Kisner, Theodore; Klein, Jeff; Korotkov, Andrei; Leach, Sam; Lee, Adrian; Levinson, Lorne; Limon, Michele; MacDermid, Kevin; Matsumura, Tomotake; Miller, Amber; Pascale, Enzo; Polsgrove, Daniel; Ponthieu, Nicolas; Raach, Kate; Reichborn-Kjennerud, Britt; Sagiv, Ilan; Tran, Huan; Tucker, Gregory S; Vinokurov, Yury; Yadav, Amit; Zaldarriaga, Matias; Zilic, Kyle; Physics, University of Minnesota School of; Astronomy,; USA,; University, Cardiff; Kingdom, United; University, McGill; Montréal,; Canada,; Avanzati, Scuola Internazionale Superiore di Studi; Trieste,; Italy,; Laboratory, Lawrence Berkeley National; USA,; University, Columbia; York, New; USA,; Standards, National Institute of; Technology,; CO, Boulder; USA,; College, Imperial; London,; Kingdom, United; California, University of; Berkeley,; USA,; University, Brown; Providence,; USA,; Science, Weizmann Institute of; Rehovot,; Israel,; Technology, California Institute of; Pasadena,; USA,; Spatiale, Institut d'Astrophysique; Paris-Sud, Universite; Orsay,; France,; Study, Institute for Advanced; Princeton,; USA,

    2010-01-01

    We present the hardware and software systems implementing autonomous operation, distributed real-time monitoring, and control for the EBEX instrument. EBEX is a NASA-funded balloon-borne microwave polarimeter designed for a 14 day Antarctic flight that circumnavigates the pole. To meet its science goals the EBEX instrument autonomously executes several tasks in parallel: it collects attitude data and maintains pointing control in order to adhere to an observing schedule; tunes and operates up to 1920 TES bolometers and 120 SQUID amplifiers controlled by as many as 30 embedded computers; coordinates and dispatches jobs across an onboard computer network to manage this detector readout system; logs over 3~GiB/hour of science and housekeeping data to an onboard disk storage array; responds to a variety of commands and exogenous events; and downlinks multiple heterogeneous data streams representing a selected subset of the total logged data. Most of the systems implementing these functions have been tested during...

  20. The role of reinstating generation operations in recognition memory and reality monitoring

    Directory of Open Access Journals (Sweden)

    Nieznański Marek

    2014-09-01

    Full Text Available The role of encoding/retrieval conditions compatibility was investigated in a reality-monitoring task. An experiment was conducted which showed a positive effect of reinstating distinctive encoding operations at test. That is, generation of a low-frequency (LF word from the same word fragment at study and test significantly enhanced item recognition memory. However, reinstating of relatively more automatic operations of reading or generating a highfrequency (HF word did not influence recognition performance. Moreover, LF words were better recognized than HF words, but memory for source did not depend on the encoding/retrieval match or on the word-frequency. In comparison with reading, generating an item at study significantly enhanced source memory but generating it at test had no effect. The data were analysed using a multinomial modelling approach which allowed ruling out the influence of a response bias on the measurement of memory ability.

  1. High-Density Fiber Optical Sensor and Instrumentation for Gas Turbine Operation Condition Monitoring

    Directory of Open Access Journals (Sweden)

    Hua Xia

    2013-01-01

    Full Text Available Gas turbine operation control is normally based on thermocouple-measured exhaust temperatures. Due to radiation shielding and bulky package, it is difficult to provide high spatial resolution for measuring can-to-can combustion temperature profile at the exhaust duct. This paper has demonstrated that wavelength-division-multiplexing-based fiber Bragg grating sensors could provide high spatial resolution steady and dynamic temperature measurements. A robust sensor package can be designed with either circumferential sensing cable or radial sensing rake for quasi-distributing multiple fiber sensors in the gas turbine environment. The field validations have demonstrated that quasi-distributed fiber sensors have not only demonstrated its temperature measurement accuracy compared to existing thermocouple sensors but also shown its unique dynamic response amplitude and power spectra that could be utilized for gas turbine transient operation condition monitoring and diagnostics.

  2. ATLAS trigger operations: Monitoring with “Xmon” rate prediction system

    CERN Document Server

    Aukerman, Andrew Todd; The ATLAS collaboration

    2017-01-01

    We present the operations and online monitoring with the “Xmon” rate prediction system for the trigger system at the ATLAS Experiment. A two-level trigger system reduces the LHC’s bunch-crossing rate, 40 MHz at design capacity, to an average recording rate of about 1 kHz, while maintaining a high efficiency of selecting events of interest. The Xmon system uses the luminosity value to predict trigger rates that are, in turn, compared with incoming rates. The predictions rely on past runs to parameterize the luminosity dependency of the event rate for a trigger algorithm. Some examples are given to illustrate the performance of the tool during recent operations.

  3. The National Aviation Operational Monitoring Service (NAOMS): A Documentation of the Development of a Survey Methodology

    Science.gov (United States)

    Connors, Mary M.; Mauro, Robert; Statler, Irving C.

    2012-01-01

    The National Aviation Operational Monitoring Service (NAOMS) was a research project under NASA s Aviation Safety Program during the years from 2000 to 2005. The purpose of this project was to develop a methodology for gaining reliable information on changes over time in the rates-of-occurrence of safety-related events as a means of assessing the safety of the national airspace. The approach was a scientifically designed survey of the operators of the aviation system concerning their safety-related experiences. This report presents the results of the methodology developed and a demonstration of the NAOMS concept through a survey of nearly 20,000 randomly selected air-carrier pilots. Results give evidence that the NAOMS methodology can provide a statistically sound basis for evaluating trends of incidents that could compromise safety. The approach and results are summarized in the report and supporting documentation and complete analyses of results are presented in 14 appendices.

  4. On the Value of Structural Health Monitoring Information for the Operation of Wind Parks

    DEFF Research Database (Denmark)

    Thöns, Sebastian; Faber, Michael H.; Val, Dimitri V.

    2017-01-01

    In the present paper, an approach for the quantification of the Value of Structural Health Monitoring (SHM) Information building upon a framework for infrastructure system utility and decision analysis is developed and applied to the operation of wind parks. The quantification of the value of SHM...... facilitates a benefit and risk informed assessment and optimization of SHM strategies and encompasses models for the infrastructure functionality, the structural constituent and system risks and its management as well as the performance of SHM strategies. A wind park system model incorporating the structural...... for the propagation of SHM information and uncertainties from components to the different system levels and vice versa. The decision to extend the service life and the operation of a wind park is investigated without SHM information and by quantifying the value of several SHM strategies....

  5. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  6. Combining models of behaviour with operational data to provide enhanced condition monitoring of AGR cores

    Energy Technology Data Exchange (ETDEWEB)

    West, Graeme M., E-mail: graeme.west@strath.ac.uk; Wallace, Christopher J.; McArthur, Stephen D.J.

    2014-06-01

    Highlights: • Combining laboratory model outputs with operational data. • Isolation of single component from noisy data. • Better understanding of the health of graphite cores. • Extended plant operation through leveraging existing data sources. - Abstract: Installation of new monitoring equipment in Nuclear Power Plants (NPPs) is often difficult and expensive and therefore maximizing the information that can be extracted from existing monitoring equipment is highly desirable. This paper describes the process of combining models derived from laboratory experimentation with current operational plant data to infer an underlying measure of health. A demonstration of this process is provided where the fuel channel bore profile, a measure of core health, is inferred from data gathered during the refuelling process of an Advanced Gas-cooled Reactor (AGR) nuclear power plant core. Laboratory simulation was used to generate a model of an interaction between the fuel assembly and the core. This model is used to isolate a single frictional component from a noisy input signal and use this friction component as a measure of health to assess the current condition of the graphite bricks that comprise the core. In addition, the model is used to generate an expected refuelling response (the noisy input signal) for a given set of channel bore diameter measurements for either insertion of new fuel or removal of spent fuel, providing validation of the model. This benefit of this work is that it provides a greater understanding of the health of the graphite core, which is important for continued and extended operation of the AGR plants in the UK.

  7. INIS: manual for online retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Schiele, J.; Kurtev, I.; Ruckenbauer, E.; Stanik, Z.; Varecka, F.; Schmid, H.

    1984-03-01

    This manual is addressed to users participating in the INIS Online Service available at the IAEA in Vienna. The retrieval system used at the IAEA is IBM/STAIRS (Storage and Information Retrieval System), installed on an IBM mainframe computer operating under OS/MVS and the TP monitor CICS. STAIRS is a multipurpose software package which enables the user to carry out retrieval on suitably structured textual and/or numerical data files in both interactive (i.e. online) and batch modes. In addition to the actual retrieval modules, the system also includes a number of auxiliary facilities which assist in the preparation and management of search files, help the users in printing the document references retrieved and in saving formulated queries for later execution or SDI processing, etc. Because of certain modifications and extensions made by the IAEA, the retrieval dialogue will be slightly different from the standard STAIRS. The present manual describes the INIS/STAIRS database and the IAEA/STAIRS retrieval language.

  8. Modelo Pedagogico de Educacion Primaria para Adultos: Manual para la Vinculacion y Funcionamiento de los Comites de Educacion para Adultos (A Teaching Model for Adult Primary Education: Manual for the Continuation and Operation of Adult Education Committees).

    Science.gov (United States)

    Instituto Nacional para la Educacion de los Adultos, Mexico City (Mexico).

    This manual is part of a Mexican series of instructional materials designed for Spanish speaking adults who are in the process of becoming literate or have recently become literate in their native language. This document describes the concept of a model for community adult education for the purpose of supporting local educational committees…

  9. Strategy for monitoring and ensuring safe operation of Russian gas transportation systems

    Directory of Open Access Journals (Sweden)

    Dudin Sergey

    2017-01-01

    Full Text Available The authors examined the legislative framework of the Russian Federation operating in the field of industrial safety, and described how to obtain a license to operate hazardous production facilities. The paper demonstrates that the importance should be given to the quality and completeness of the background information, as well as the choice of inspection strategy in evaluating the technical condition of the line section of main gas pipelines. As a part of a package of measures to ensure industrial safety and technical reliability of existing gas pipelines it is proposed to carry out conditioning of their line sections. The paper describes general requirements for pipeline inspection, which include: detection efficiency of dangerous damages and major leaks, maximum accuracy of detection of the defect location, continuity of monitoring throughout the entire range of operation modes of the pipeline, cost recovery at the stages of development and operation of control systems, forecasting the state of the pipeline and the effects of accidents. In practice, these parameters have the prevailing significance.

  10. Operation reliability assessment for cutting tools by applying a proportional covariate model to condition monitoring information.

    Science.gov (United States)

    Cai, Gaigai; Chen, Xuefeng; Li, Bing; Chen, Baojia; He, Zhengjia

    2012-09-25

    The reliability of cutting tools is critical to machining precision and production efficiency. The conventional statistic-based reliability assessment method aims at providing a general and overall estimation of reliability for a large population of identical units under given and fixed conditions. However, it has limited effectiveness in depicting the operational characteristics of a cutting tool. To overcome this limitation, this paper proposes an approach to assess the operation reliability of cutting tools. A proportional covariate model is introduced to construct the relationship between operation reliability and condition monitoring information. The wavelet packet transform and an improved distance evaluation technique are used to extract sensitive features from vibration signals, and a covariate function is constructed based on the proportional covariate model. Ultimately, the failure rate function of the cutting tool being assessed is calculated using the baseline covariate function obtained from a small sample of historical data. Experimental results and a comparative study show that the proposed method is effective for assessing the operation reliability of cutting tools.

  11. Wildlife mitigation burn monitoring program at Teck Coal Limited : Fording River Operations

    Energy Technology Data Exchange (ETDEWEB)

    Smyth, C.R. [Summit Environmental Consultants Inc., Calgary, AB (Canada); Caldwell, T.; Sword, G. [Teck Coal Ltd., Fording River Operations, Elkford, BC (Canada)

    2010-07-01

    This articled discussed a monitoring program evaluating the results of prescribed burns with respect to forest cover reduction, forest production, and wildlife utilization. The burn treatments were undertaken to mitigate the effects of ungulate habitat loss resulting from mine expansion and to increase wildlife habitat suitability and provide winter habitat for elk and moose. Pre-burn and post-burn aerial photographs were used to evaluate the effects of the burn treatments. Data on vegetation, wildlife use, and standing crop production were collected from 36 transects located in paired burned and unburned habitats during the course of the monitoring program, which operated from 1998 to 2007. The mitigation burns were generally found to be successful at improving ungulate habitat. Despite variation among treatment areas and years, the standing crop measurements showed that forest production and animal unit months were greater in the burn treatment areas than in the unburned areas. In particular, the increased cover of palatable grasses and forbs enhanced the elk winter range. The burn treatments altered the stand structure and species dominance. Signs of habitat use showed that elk and mule deer preferentially used the burned sites during the monitoring period. 14 refs., 1 fig.

  12. Operations of cleanrooms during a forest fire including protocols and monitoring results

    Science.gov (United States)

    Matheson, Bruce A.; Egges, Joanne; Pirkey, Michael S.; Lobmeyer, Lynette D.

    2012-10-01

    Contamination-sensitive space flight hardware is typically built in cleanroom facilities in order to protect the hardware from particle contamination. Forest wildfires near the facilities greatly increase the number of particles and amount of vapors in the ambient outside air. Reasonable questions arise as to whether typical cleanroom facilities can adequately protect the hardware from these adverse environmental conditions. On Monday September 6, 2010 (Labor Day Holiday), a large wildfire ignited near the Boulder, Colorado Campus of Ball Aerospace. The fire was approximately 6 miles from the Boulder City limits. Smoke levels from the fire stayed very high in Boulder for the majority of the week after the fire began. Cleanroom operations were halted temporarily on contamination sensitive hardware, until particulate and non-volatile residue (NVR) sampling could be performed. Immediate monitoring showed little, if any effect on the cleanroom facilities, so programs were allowed to resume work while monitoring continued for several days and beyond in some cases. Little, if any, effect was ever noticed in the monitoring performed.

  13. Passive seismic data management and processing to monitor heavy oil steaming operations

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.R.; Wang, L. [Society of Petroleum Engineers, Richardson, TX (United States)]|[ExxonMobil Upstream Research Co., Houston, TX (United States); Searles, K.H.; Smith, R.J.; Keith, C.M. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Imperial Oil Ltd., Burnaby, BC (Canada)

    2008-10-15

    Cyclic steam injection (CSS) is a cost-effective means to produce heavy oil at the Cold Lake field in Alberta, Canada. The primary obstacle to economic production is the high viscosity of the bitumen. However the bitumen viscosity decreases significantly with temperature. Steam is injected at fracturing conditions, resulting in dilation and recompaction which propagates stress and strain fields in the overburden. An important design consideration involves the mechanical loads on wells resulting from this production process. A seismic production monitoring system was developed in 1995 in the Cold Lake field in order to provide early detection of casing failures and possible fracturing of the overburden. The method was shown to detect a high percentage of casing failures in the production monitoring system. This paper discussed the use and application of methods developed for passive seismic data analysis. The Cold Lake passive seismic system (CLPS) has evolved into an integrated process with a daily workflow. Personnel have identified roles and responsibilities. The paper provided a discussion of the development of a web-based platform running on the operator's internal network called PSWeb. The progression of work in microseismic monitoring of fracture stimulation treatments was also discussed along with the development of FIDO, which used graphical event processing methods to facilitate data analysis and interpretation. Further development of these tools is ongoing to improve casing failure detection and to incorporate more information from seismic data to understand the impact of the CSS process on overburden integrity. 15 refs., 12 figs., 1 appendix.

  14. Online total organic carbon (TOC) monitoring for water and wastewater treatment plants processes and operations optimization

    Science.gov (United States)

    Assmann, Céline; Scott, Amanda; Biller, Dondra

    2017-08-01

    Organic measurements, such as biological oxygen demand (BOD) and chemical oxygen demand (COD) were developed decades ago in order to measure organics in water. Today, these time-consuming measurements are still used as parameters to check the water treatment quality; however, the time required to generate a result, ranging from hours to days, does not allow COD or BOD to be useful process control parameters - see (1) Standard Method 5210 B; 5-day BOD Test, 1997, and (2) ASTM D1252; COD Test, 2012. Online organic carbon monitoring allows for effective process control because results are generated every few minutes. Though it does not replace BOD or COD measurements still required for compliance reporting, it allows for smart, data-driven and rapid decision-making to improve process control and optimization or meet compliances. Thanks to the smart interpretation of generated data and the capability to now take real-time actions, municipal drinking water and wastewater treatment facility operators can positively impact their OPEX (operational expenditure) efficiencies and their capabilities to meet regulatory requirements. This paper describes how three municipal wastewater and drinking water plants gained process insights, and determined optimization opportunities thanks to the implementation of online total organic carbon (TOC) monitoring.

  15. 40 CFR 63.3968 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Science.gov (United States)

    2010-07-01

    .... Monitoring failures that are caused in part by poor maintenance or careless operation are not malfunctions... install a device to monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and...

  16. 40 CFR Table 6 to Subpart Ppp of... - Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements 6 Table 6 to Subpart PPP of Part 63... Subpart PPP of Part 63—Process Vents From Continuous Unit Operations—Monitoring, Recordkeeping, and...

  17. [Hardware-software system for monitoring parameters and characteristics of X-ray computer tomographs under operation conditions].

    Science.gov (United States)

    Blinov, N N; Zelikman, M I; Kruchinin, S A

    2007-01-01

    The results of testing of hardware and software for monitoring parameters (mean number of CT units, noise, field uniformity, high-contrast spatial resolution, layer width, dose) and characteristics (modulation transfer function) of X-ray computer tomographs are presented. The developed hardware and software are used to monitor the stability of X-ray computer tomograph parameters under operation conditions.

  18. Generalized Monitoring Facility. Users Manual.

    Science.gov (United States)

    1982-05-01

    should do so with great care since TSS response might be severely degraded if GMC prevents TSS (TS,) from growing in size. The procedures for...report should be similar to Report 1, unless a great amount of GEMORE, GERLEC, or swap 6-32 5-44 CD4 en ’T cz I z4 0 c co u u- co 0F 0 .;coc ufl CO...is the most active disk device with device 21 being a very close second. The device numbers being reported under the " DEVID " column are the unique

  19. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  20. 33 CFR 127.1307 - Emergency Manual.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Emergency Manual. 127.1307... Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1307 Emergency Manual. (a) Each Emergency Manual must contain— (1) For each LHG handled— (i) A physical description of the LHG; (ii)...

  1. MOSS user's manual

    Science.gov (United States)

    Salmen, Larry; Gropper, James; Hamill, John; Gentry, Barbara

    1978-01-01

    The Map Overlay and Statistical System (MOSS) Users' Manual is specialized document has been designed for trained users of the MOSS interactive graphics software. Those totally unfamiliar with MOSS or Geographic Information Systems are referred elsewhere as described below: -- If you know nothing about MOSS or what it can do for you, and you wish introductory information on MOSS, or you want to deign an application and data entry process compatible with MOSS, or you want "hands-on" training, contact the WELUT Team Leader at the address below for a "hands-on" GIS training session. -- If you have been introduced to MOSS, have your application defined, data entered, and want to know how to use MOSS, start reading at Section 1 of this Manual. --If you are interested in the MOSS data structure, refer to Section 2 of this Manual. --If you have some experience in using MOSS and want to refer to the general types of MOSS commands, read Section 3 of this Manual. --If you are an experience MOSS user and want details on individual MOSS commands, refer to Section 4.3 of this Manual. --If you are interested in the Federation of Rocky Mountain States -- WELUT 02 Project contractual background results, turn to Appendices D and E of this Manual. MOSS has been operation for less than 3 months, and has received limited operational testing at the date of this printing (October 1978). Undiscovered software limitations and bugs may yet appear. All such bugs as well as documentation errors, obscurities, and inadequacies should be reported to: Team Leader

  2. Capability of C-Band SAR for Operational Wetland Monitoring at High Latitudes

    Directory of Open Access Journals (Sweden)

    Julia Reschke

    2012-10-01

    Full Text Available Wetlands store large amounts of carbon, and depending on their status and type, they release specific amounts of methane gas to the atmosphere. The connection between wetland type and methane emission has been investigated in various studies and utilized in climate change monitoring and modelling. For improved estimation of methane emissions, land surface models require information such as the wetland fraction and its dynamics over large areas. Existing datasets of wetland dynamics present the total amount of wetland (fraction for each model grid cell, but do not discriminate the different wetland types like permanent lakes, periodically inundated areas or peatlands. Wetland types differently influence methane fluxes and thus their contribution to the total wetland fraction should be quantified. Especially wetlands of permafrost regions are expected to have a strong impact on future climate due to soil thawing. In this study ENIVSAT ASAR Wide Swath data was tested for operational monitoring of the distribution of areas with a long-term SW near 1 (hSW in northern Russia (SW = degree of saturation with water, 1 = saturated, which is a specific characteristic of peatlands. For the whole northern Russia, areas with hSW were delineated and discriminated from dynamic and open water bodies for the years 2007 and 2008. The area identified with this method amounts to approximately 300,000 km2 in northern Siberia in 2007. It overlaps with zones of high carbon storage. Comparison with a range of related datasets (static and dynamic showed that hSW represents not only peatlands but also temporary wetlands associated with post-forest fire conditions in permafrost regions. Annual long-term monitoring of change in boreal and tundra environments is possible with the presented approach. Sentinel-1, the successor of ENVISAT ASAR, will provide data that may allow continuous monitoring of these wetland dynamics in the future complementing global observations of

  3. Operational Test and Evaluation Manual

    Science.gov (United States)

    2011-06-28

    girdle scoring areas) placed 10 feet apart with one shot a piece in the head or chest scoring area at 500 meters in 15 seconds or less. (T) 15...seconds or less The REPR shall be capable of engaging 3 E-Type Silhouette targets (modified for MCMP Table II showing head, chest, and pelvic girdle

  4. Ozone monitoring in the UK (United Kingdom): A review of 1978/8. Data from monitoring sites operated by Warren Spring Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Bower, J.S.; Broughton, G.F.; Dando, M.T.

    1988-01-01

    A new national air-quality monitoring network has been established for the Department of the Environment. Its purpose is to determine rural baseline concentrations of ozone and other pollutants throughout the United Kingdom. The report describes the background to the establishment of the network, together with its present structure and instrumentation. A series of data analyses are presented and discussed, with the intention of providing a broad and preliminary overview of ozone observations at WSL-operated monitoring sites throughout the first full year of network operation. Average and peak levels of ozone during 1987/8 are quantified, seasonal and diurnal variations are determined, and high pollution periods are examined.

  5. CMEMS (Copernicus Marine Environment Monitoring Service) In Situ Thematic Assembly Centre: A service for operational Oceanography

    Science.gov (United States)

    Manzano Muñoz, Fernando; Pouliquen, Sylvie; Petit de la Villeon, Loic; Carval, Thierry; Loubrieu, Thomas; Wedhe, Henning; Sjur Ringheim, Lid; Hammarklint, Thomas; Tamm, Susanne; De Alfonso, Marta; Perivoliotis, Leonidas; Chalkiopoulos, Antonis; Marinova, Veselka; Tintore, Joaquin; Troupin, Charles

    2016-04-01

    Copernicus, previously known as GMES (Global Monitoring for Environment and Security), is the European Programme for the establishment of a European capacity for Earth Observation and Monitoring. Copernicus aims to provide a sustainable service for Ocean Monitoring and Forecasting validated and commissioned by users. From May 2015, the Copernicus Marine Environment Monitoring Service (CMEMS) is working on an operational mode through a contract with services engagement (result is regular data provision). Within CMEMS, the In Situ Thematic Assembly Centre (INSTAC) distributed service integrates in situ data from different sources for operational oceanography needs. CMEMS INSTAC is collecting and carrying out quality control in a homogeneous manner on data from providers outside Copernicus (national and international networks), to fit the needs of internal and external users. CMEMS INSTAC has been organized in 7 regional Dissemination Units (DUs) to rely on the EuroGOOS ROOSes. Each DU aggregates data and metadata provided by a series of Production Units (PUs) acting as an interface for providers. Homogeneity and standardization are key features to ensure coherent and efficient service. All DUs provide data in the OceanSITES NetCDF format 1.2 (based on NetCDF 3.6), which is CF compliant, relies on SeaDataNet vocabularies and is able to handle profile and time-series measurements. All the products, both near real-time (NRT) and multi-year (REP), are available online for every CMEMS registered user through an FTP service. On top of the FTP service, INSTAC products are available through Oceanotron, an open-source data server dedicated to marine observations dissemination. It provides services such as aggregation on spatio-temporal coordinates and observed parameters, and subsetting on observed parameters and metadata. The accuracy of the data is checked on various levels. Quality control procedures are applied for the validity of the data and correctness tests for the

  6. 33 CFR 127.307 - Emergency Manual.

    Science.gov (United States)

    2010-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.307 Emergency Manual. Each...

  7. Operational control of radiation conditions in Space Monitoring Data Center of Moscow State University

    Science.gov (United States)

    Kalegaev, Vladimir; Shugay, Yulia; Bobrovnikov, Sergey; Kuznetsov, Nikolay; Barinova, Vera; Myagkova, Irina; Panasyuk, Mikhail

    2016-07-01

    Space Monitoring Data Center (SMDC) of Moscow State University provides mission support for Russian satellites and give operational analysis of radiation conditions in space. SMDC Web-sites (http://smdc.sinp.msu.ru/ and http://swx.sinp.msu.ru/) give access to current data on the level of solar activity, geomagnetic and radiation state of Earth's magnetosphere and heliosphere in near-real time. For data analysis the models of space environment factors working online have been implemented. Interactive services allow one to retrieve and analyze data at a given time moment. Forecasting applications including solar wind parameters, geomagnetic and radiation condition forecasts have been developed. Radiation dose and SEE rate control are of particular importance in practical satellite operation. Satellites are always under the influence of high-energy particle fluxes during their orbital flight. The three main sources of particle fluxes: the Earth's radiation belts, the galactic cosmic rays, and the solar energetic particles (SEP), are taken into account by SMDC operational services to estimate the radiation dose caused by high-energy particles to a satellite at LEO orbits. ISO 15039 and AP8/AE8 physical models are used to estimate effects of galactic cosmic rays and radiation belt particle fluxes. Data of geosynchronous satellites (GOES or Electro-L1) allow to reconstruct the SEP fluxes spectra at a given low Earth orbit taking into account the geomagnetic cut-off depending on geomagnetic activity level.

  8. Microbial air monitoring in the operating theatres of Salam Center for Cardiac Surgery in Khartoum (Sudan

    Directory of Open Access Journals (Sweden)

    Margherita Scapaticci

    2012-06-01

    Full Text Available The seriousness of postoperative infections and the increased susceptibility of patients undergoing cardiac surgery increase the demand for the operating theatre (OT asepsis to prevent bacterial infections. In fact, the organisms carried by the air reach the wound after having sedimented onto sterile field. The air represents a critical point for quality control of air filtration systems, for sanitization procedures and for the evolution of hygienic features of the OT environment.Aim of the study is to evaluate the prevalence of microorganisms found in the operating rooms (OR air monitoring in the Salam Center for Cardiac Surgery of Khartoum (Sudan between July 2008 and March 2009.The specimens were collected every month in two different times: “OR at rest” (after sanitization and “OR operational”, using sedimentation method (Fisher 1972. Results showed that each sample collected at rest had IMA (index of microbial air contamination < 5CFU/plt, whereas the bacterial growth was between 25 and 50 CFU/plt when the samples had been collected in the same places during operating activities.This indicate the effectiveness of sanitization procedures and confirm that people working in OT are an important source of bacteria causing postoperative infections. Coagulase negative Staphylococci, Gram negative bacillus and Staphylococcus aureus spp. were the predominant organisms isolated.

  9. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  10. The Comparative Analysis of Efficiency and Quality between Farm Machinery Operation and Manual Operation%农机作业与人工作业的效率质量比较分析

    Institute of Scientific and Technical Information of China (English)

    罗敬东

    2016-01-01

    随着国家购机补贴政策的逐年实施,玉龙县农业机械结构实现了优化调整.通过对几种主要农业机械与人工作业的效率质量比较分析,得出的结论与建议是:玉龙县农机化的发展既应继续支持微耕机的推广使用,又要扶持发展大中型高性能拖拉机;联合收割机应根据实际需求选择适用机型;要重视农机维修服务网点建设.%With the implementation of national buyers subsidy policy,agricultural machinery structure in Yulong has been optimized and adjusted.Through comparative analysis of efficiency and quality between farm machinery operation and manual op-eration, it concludes that the development of agricultural mechanization should support the promotion of both micro tillage ma-chine and large sized high performance tractor,and it should attach importance to the construction of agricultural machinery maintenance service network.

  11. Collaboration pathway(s) using new tools for optimizing `operational' climate monitoring from space

    Science.gov (United States)

    Helmuth, Douglas B.; Selva, Daniel; Dwyer, Morgan M.

    2015-09-01

    Consistently collecting the earth's climate signatures remains a priority for world governments and international scientific organizations. Architecting a long term solution requires transforming scientific missions into an optimized robust `operational' constellation that addresses the collective needs of policy makers, scientific communities and global academic users for trusted data. The application of new tools offers pathways for global architecture collaboration. Recent rule-based expert system (RBES) optimization modeling of the intended NPOESS architecture becomes a surrogate for global operational climate monitoring architecture(s). These rulebased systems tools provide valuable insight for global climate architectures, by comparison/evaluation of alternatives and the sheer range of trade space explored. Optimization of climate monitoring architecture(s) for a partial list of ECV (essential climate variables) is explored and described in detail with dialogue on appropriate rule-based valuations. These optimization tool(s) suggest global collaboration advantages and elicit responses from the audience and climate science community. This paper will focus on recent research exploring joint requirement implications of the high profile NPOESS architecture and extends the research and tools to optimization for a climate centric case study. This reflects work from SPIE RS Conferences 2013 and 2014, abridged for simplification30, 32. First, the heavily securitized NPOESS architecture; inspired the recent research question - was Complexity (as a cost/risk factor) overlooked when considering the benefits of aggregating different missions into a single platform. Now years later a complete reversal; should agencies considering Disaggregation as the answer. We'll discuss what some academic research suggests. Second, using the GCOS requirements of earth climate observations via ECV (essential climate variables) many collected from space-based sensors; and accepting their

  12. Hardware and software system for monitoring oil pump operation in power high-voltage transformers

    Directory of Open Access Journals (Sweden)

    Михайло Дмитрович Дяченко

    2017-07-01

    Full Text Available The article considers the basic prerequisites for the creation of an automated monitoring system for oil pumps of high-voltage transformers. This is due to the fact that the long operation of oil pumps results in deterioration and destruction of bearings, rubbing of the rotor, breakage and damage to the impeller, leakage, etc., which inevitably causes a significant decrease in the insulating properties of the transformer oil and leads to expenditures for its further recovery. False triggerings of gas protection sometimes occur. Continuous operation of the electric motor also requires additional equipment to protect the motor itself from various emergency situations, such as a short in the stator winding, a housing breakdown, an incomplete phase mode, etc. The use of stationary systems provides: diagnosing defects at an early stage of their development, increasing the reliability and longevity of the equipment components, increasing the overhaul period, decreasing the number of emergency stops, and adjusting the schedule of preventative maintenance. The basic principles of identification of the damaged part of the oil pump are given, the hardware and algorithmic solutions are considered in the work. The full-scale tests of the model sample on the power transformer of the high-voltage substation confirmed the assumption of the possibility of detecting the damaged unit separating it from the rest connected in one mechanical structure. A detailed analysis of the operation of each of the units is carried out by means of the general substation switchboard and displayed as graphs, diagrams and text messages. When the limit values of vibration are reached, faults in the operation of the unit are detected, the overlimit current values, a warning alarm is activated, and the command to disconnect the damaged unit is issued. The optimal solution for the organization of the information collection system using the principle of sensor networks, but combined

  13. Operation Safe Haven: an evaluation of health surveillance and monitoring in an acute setting.

    Science.gov (United States)

    Bennett, C; Mein, J; Beers, M; Harvey, B; Vemulpad, S; Chant, K; Dalton, C

    2000-02-17

    From May to June 1999, 3,920 ethnic Albanians from Kosovo arrived in Australia as part of Operation Safe Haven. These people were evacuated from refugee camps in the former Yugoslav Republic of Macedonia. Initial processing in Australia occurred at East Hills Reception Centre, and accommodation for the duration of stay was provided in eight Haven Centres in five States. The arrival of a large number of refugees in a short time frame is unprecedented in Australia. A health surveillance system was developed and critical health data were collected to assess health status and needs, plan care, monitor for potential outbreaks of communicable diseases, track service use, to meet international reporting requirements and document our response to this crisis. In this article the health surveillance system is evaluated and suggestions are offered for the formulation of specific guidelines necessary for health surveillance in acute settings.

  14. Real-time monitoring and operational control of drinking-water systems

    CERN Document Server

    Ocampo-Martínez, Carlos; Pérez, Ramon; Cembrano, Gabriela; Quevedo, Joseba; Escobet, Teresa

    2017-01-01

    This book presents a set of approaches for the real-time monitoring and control of drinking-water networks based on advanced information and communication technologies. It shows the reader how to achieve significant improvements in efficiency in terms of water use, energy consumption, water loss minimization, and water quality guarantees. The methods and approaches presented are illustrated and have been applied using real-life pilot demonstrations based on the drinking-water network in Barcelona, Spain. The proposed approaches and tools cover: • decision-making support for real-time optimal control of water transport networks, explaining how stochastic model predictive control algorithms that take explicit account of uncertainties associated with energy prices and real demand allow the main flow and pressure actuators—pumping stations and pressure regulation valves—and intermediate storage tanks to be operated to meet demand using the most sustainable types of source and with minimum electricity costs;...

  15. Track-monitoring from the dynamic response of an operational train

    Science.gov (United States)

    Lederman, George; Chen, Siheng; Garrett, James; Kovačević, Jelena; Noh, Hae Young; Bielak, Jacobo

    2017-03-01

    We explore a data-driven approach for monitoring rail infrastructure from the dynamic response of a train in revenue-service. Presently, track inspection is performed either visually or with dedicated track geometry cars. In this study, we examine a more economical approach where track inspection is performed by analyzing vibration data collected from an operational passenger train. The high frequency with which passenger trains travel each section of track means that faults can be detected sooner than with dedicated inspection vehicles, and the large number of passes over each section of track makes a data-driven approach statistically feasible. We have deployed a test-system on a light-rail vehicle and have been collecting data for the past two years. The collected data underscores two of the main challenges that arise in train-based track monitoring: the speed of the train at a given location varies from pass to pass and the position of the train is not known precisely. In this study, we explore which feature representations of the data best characterize the state of the tracks despite these sources of uncertainty (i.e., in the spatial domain or frequency domain), and we examine how consistently change detection approaches can identify track changes from the data. We show the accuracy of these different representations, or features, and different change detection approaches on two types of track changes, track replacement and tamping (a maintenance procedure to improve track geometry), and two types of data, simulated data and operational data from our test-system. The sensing, signal processing, and data analysis we propose in the study could facilitate safer trains and more cost-efficient maintenance in the future. Moreover, the proposed approach is quite general and could be extended to other parts of the infrastructure, including bridges.

  16. Statistically Filtering Data for Operational Modal Analysis under Ambient Vibration in Structural Health Monitoring Systems

    Directory of Open Access Journals (Sweden)

    Wang Liang

    2016-01-01

    Full Text Available Operational modal analysis (OMA is prevalent in large structure modal identification for that it asks for output measurements only. To guarantee identification accuracy, theoretically, OMA data need to be a random process of Gaussian white noise (GWN. Although numerous OMA applications are found in practice, few have particularly discussed the data distribution and to what extent it would blur the modal judgement. This paper presents a method to sieve segments mostly obeying the GWN distribution out of a recording. With a windowing technique, the data segments are evaluated by the modified Kurtosis value. The process has been demonstrated on the monitoring data of two case study structures: one is a laboratory truss bridge excited by artificial forces, the other is a real cable-stayed bridge subject to environmental loads. The results show that weak randomness data may result in false peaks that would possibly mislead the non-parametric modal identification, such as using the Frequency Domain Decomposition method. To overcome, cares on selecting the optimal segment shall be exercised. The proposed method is verified effective to find the most suitable data for modal identification of structural health monitoring systems.

  17. Experience of molecular monitoring techniques in upstream oil and gas operations

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Anthony F.; Anfindsen, Hilde; Liengen, Turid; Molid, Solfrid [Statoil ASA (Denmark)

    2011-07-01

    For a numbers of years, molecular monitoring tools have been used in upstream oil and gas operations but the results have given only limited added value. This paper discusses the various techniques available for upstream molecular monitoring which provides scope for identification of microbial influenced problems. The methodology, which consists of analyzing solid samples using traditional as well as molecular techniques, is detailed. Two cases were studied with the objective of determining if microbial contamination was contributing to the problem. The first case was a study of amorphous deposits in production wells and mainly iron sulphide was found. The second study was of amorphous deposits in water injection wells and the analysis showed typical components of drilling and completion fluids with some organic material. Two more cases, corrosion of tubing in a water injection well and flow line corrosion, are discussed and the results are given. From the study, it can be concluded that failure can be due to several factors, chemical and biological.

  18. Advances in Remote Sensing of Agriculture: Context Description, Existing Operational Monitoring Systems and Major Information Needs

    Directory of Open Access Journals (Sweden)

    Clement Atzberger

    2013-02-01

    Full Text Available Many remote sensing applications are devoted to the agricultural sector. Representative case studies are presented in the special issue “Advances in Remote Sensing of Agriculture”. To complement the examples published within the special issue, a few main applications with regional to global focus were selected for this review, where remote sensing contributions are traditionally strong. The selected applications are put in the context of the global challenges the agricultural sector is facing: minimizing the environmental impact, while increasing production and productivity. Five different applications have been selected, which are illustrated and described: (1 biomass and yield estimation, (2 vegetation vigor and drought stress monitoring, (3 assessment of crop phenological development, (4 crop acreage estimation and cropland mapping and (5 mapping of disturbances and land use/land cover (LULC changes. Many other applications exist, such as precision agriculture and irrigation management (see other special issues of this journal, but were not included to keep the paper concise. The paper starts with an overview of the main agricultural challenges. This section is followed by a brief overview of existing operational monitoring systems. Finally, in the main part of the paper, the mentioned applications are described and illustrated. The review concludes with some key recommendations.

  19. Integrating UF6 Cylinder RF Tracking With Continuous Load Cell Monitoring for Verifying Declared UF6 Feed and Withdrawal Operations Verifying Declared UF6 Feed and Withdrawal Operations

    Energy Technology Data Exchange (ETDEWEB)

    Krichinsky, Alan M [ORNL; Miller, Paul [ORNL; Pickett, Chris A [ORNL; Richardson, Dave [ORNL; Rowe, Nathan C [ORNL; Whitaker, J Michael [ORNL; Younkin, James R [ORNL

    2009-01-01

    Oak Ridge National Laboratory is demonstrating the integration of UF6 cylinder tracking, using RF technology, with continuous load cell monitoring (CLCM) at mock UF6 feed and withdrawal (F&W) stations. CLCM and cylinder tracking are two of several continuous-monitoring technologies that show promise in providing integrated safeguards of F&W operations at enrichment plants. Integrating different monitoring technologies allows advanced, automated event processing to screen innocuous events thereby minimizing false alerts to independent inspectors. Traditionally, international inspectors rely on batch verification of material inputs and outputs derived from operator declarations and periodic on-site inspections at uranium enrichment plants or other nuclear processing facilities. Continuously monitoring F&W activities between inspections while providing filtered alerts of significant operational events will substantially increase the amount of valuable information available to inspectors thereby promising to enhance the effectiveness of safeguards and to improve efficiency in conducting on-site inspections especially at large plants for ensuring that all operations are declared.

  20. Cloud Cover Assessment for Operational Crop Monitoring Systems in Tropical Areas

    Directory of Open Access Journals (Sweden)

    Isaque Daniel Rocha Eberhardt

    2016-03-01

    Full Text Available The potential of optical remote sensing data to identify, map and monitor croplands is well recognized. However, clouds strongly limit the usefulness of optical imagery for these applications. This paper aims at assessing cloud cover conditions over four states in the tropical and sub-tropical Center-South region of Brazil to guide the development of an appropriate agricultural monitoring system based on Landsat-like imagery. Cloudiness was assessed during overlapping four months periods to match the typical length of crop cycles in the study area. The percentage of clear sky occurrence was computed from the 1 km resolution MODIS Cloud Mask product (MOD35 considering 14 years of data between July 2000 and June 2014. Results showed high seasonality of cloud occurrence within the crop year with strong variations across the study area. The maximum seasonality was observed for the two states in the northern part of the study area (i.e., the ones closer to the Equator line, which also presented the lowest averaged values (15% of clear sky occurrence during the main (summer cropping period (November to February. In these locations, optical data faces severe constraints for mapping summer crops. On the other hand, relatively favorable conditions were found in the southern part of the study region. In the South, clear sky values of around 45% were found and no significant clear sky seasonality was observed. Results underpin the challenges to implement an operational crop monitoring system based solely on optical remote sensing imagery in tropical and sub-tropical regions, in particular if short-cycle crops have to be monitored during the cloudy summer months. To cope with cloudiness issues, we recommend the use of new systems with higher repetition rates such as Sentinel-2. For local studies, Unmanned Aircraft Vehicles (UAVs might be used to augment the observing capability. Multi-sensor approaches combining optical and microwave data can be another

  1. [The possibilities for the transcranial monitoring of the blood flow in the circle of Willis arteries during operations on the brachiocephalic arteries and in heart operations].

    Science.gov (United States)

    Kuntsevich, G I; Kaĭdash, A N; Ter-Khachaturova, I E; Kovalevskaia, O A

    1995-01-01

    The paper gives the results of arterial blood flow monitoring in the circle of Willis via transcranial Doppler during 81 reparative operations on brachiocephalic arteries (including carotid endarterectomy from the internal carotid artery in 32 patients). Transcranial monitoring of blood flow supports the fact that there is a collateral reflow along the cerebral arteries during removal of the common carotid artery and that there is a relationship between the status of great arteries and arteries of Willis' circle. The paper also summaries the results of a comprehensive ultrasound study of 9 patients who have undergone reparative and plastic operations on the cardiac valves during extracorporeal circulation and general hypothermia. Blood flow was intraoperatively monitored in the arteries of the basis cerebri by using transcranial duplex scanning with colour Doppler flow mapping to evaluate not only hemodynamics, but also the embolic situation, as well as to check up how air was removed from the cardiac cavities by transesophageal echocardiography.

  2. Tethered Satellites as an Enabling Platform for Operational Space Weather Monitoring Systems

    Science.gov (United States)

    Gilchrist, Brian E.; Krause, Linda Habash; Gallagher, Dennis Lee; Bilen, Sven Gunnar; Fuhrhop, Keith; Hoegy, Walt R.; Inderesan, Rohini; Johnson, Charles; Owens, Jerry Keith; Powers, Joseph; Voronka, Nestor; Williams, Scott

    2013-01-01

    Tethered satellites offer the potential to be an important enabling technology to support operational space weather monitoring systems. Space weather "nowcasting" and forecasting models rely on assimilation of near-real-time (NRT) space environment data to provide warnings for storm events and deleterious effects on the global societal infrastructure. Typically, these models are initialized by a climatological model to provide "most probable distributions" of environmental parameters as a function of time and space. The process of NRT data assimilation gently pulls the climate model closer toward the observed state (e.g., via Kalman smoothing) for nowcasting, and forecasting is achieved through a set of iterative semi-empirical physics-based forward-prediction calculations. Many challenges are associated with the development of an operational system, from the top-level architecture (e.g., the required space weather observatories to meet the spatial and temporal requirements of these models) down to the individual instruments capable of making the NRT measurements. This study focuses on the latter challenge: we present some examples of how tethered satellites (from 100s of m to 20 km) are uniquely suited to address certain shortfalls in our ability to measure critical environmental parameters necessary to drive these space weather models. Examples include long baseline electric field measurements, magnetized ionospheric conductivity measurements, and the ability to separate temporal from spatial irregularities in environmental parameters. Tethered satellite functional requirements are presented for two examples of space environment observables.

  3. An Operational System For Monitoring Oil Spills In The Mediterranean Sea: The PROMED System

    Directory of Open Access Journals (Sweden)

    I. KERAMITSOGLOU

    2012-12-01

    Full Text Available The primary objective of this work was the development of an operational system for early detection of oil-spills, monitoring of their evolution, and provision of support to responsible Public Authorities during cleanup operations, based on Remote Sensing and GIS technologies. In case of emergency, the principal characteristics of the oil spill are defined with the aid of a space-borne synthetic aperture radar (SAR. The transport, spreading and dispersion of the oil spill is subsequently simulated on the basis of wind forecasts of the area. The use of thematic maps of protected, fishing and urban areas, and regions of high tourism allows the better assessment of the impact of an oil spill on the areas to be affected in terms of environmental sensitivity. Finally, reports are generated notifying port authorities, the media, and local organizations to be potentially affected by the presence of the oil spill. The pilot site for testing the PROMED System in Greece is the island of Crete.

  4. [Unexpected atrial fibrillation when monitoring in operating room. Case of the trimester].

    Science.gov (United States)

    2014-05-01

    A real case reported to the SENSAR database of incidents is presented. In a patient scheduled for nose fracture repair surgery an unexpected atrial fibrillation was found when monitored in the operating room. The operation was not delayed. After induction of general anaesthesia heart rate suddenly increased and hemodinamic situation was impaired. Cardioversion was required. Two electric countershocks were given but sinus rhythm was not restored. Heart rate was controlled with amiodarone infusion. Optimal defibrillation characteristics are described in these cases. Increased risk of thromboembolism (1-2%) following cardioversion is present even if atrial thrombi are ruled out. The mainstay therapies of are rhythm and rate control and prevention of thromboembolic complications. We describe recommendations on the management of these critical situations with emphasis in learning through the creation of protocols and training practice in simulation. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  5. In situ monitoring of animal micronuclei before the operation of Daya Bay Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Y.N. Cai; H.Y. He; L.M. Qian; G.C. Sun; J.Y. Zhao [Guangzhou College of Education, Guangzhou (China)

    1994-12-31

    Daya Bay Nuclear Power Station, a newly-built nuclear power station in southern mainland China, started its operation in 1993. We examined micro-nucleated cells of Invertibrate (Bivalves) and Vertibrate (Fish and Amphibia) in different spots within the 50km surroundings of the Power Station during 1986-1993. This paper reports the results of the investigation carried out in Dong Shan, a place 4.7km to the Power Station:Bivalves; Pteria martensil 5.1(1986),4.8(1988),4.8(1991),5,0(1993),Mytilus smardinus 4.7(1987),4.6(1988); Chamys nobilis 4.9(1987);4.9(1991),4.5(1992),4.5(1993). Fish; Therapon jarbua 0.48(1991),0.67(1992),0.47(1993). Amphibia; Bufo melanostictus 0.29 (1987), 0.34(1988),0.39(1992),0.39(1993). These results showed that the environmental situation, estimated by using the frequencies of micronucleated cells, was stable-there was no obvious chromosome damage in the animals studied. It was found that the incidence of micronucleated cells of Bivalves was higher than that of Fish and Amphibia, suggesting the epithelial cells to be more sensitive than peripheral erythrocytes to environmental genotoxic effects. The results of our studies for other spots will be reported afterward. These data can be used as the original background information to monitor the environment when the Nuclear Power Station is in operation.

  6. Preliminary Concept of Operations for a Global Cylinder Identification and Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, J. M. [ORNL; White-Horton, J. L. [ORNL; Morgan, J. B. [InSolves Associates

    2013-08-01

    This report describes a preliminary concept of operations for a Global Cylinder Identification and Monitoring System that could improve the efficiency of the International Atomic Energy Agency (IAEA) in conducting its current inspection activities and could provide a capability to substantially increase its ability to detect credible diversion scenarios and undeclared production pathways involving UF6 cylinders. There exist concerns that a proliferant State with access to enrichment technology could obtain a cylinder containing natural or low-enriched uranium hexafluoride (UF6) and produce a significant quantity (SQ)1 of highly enriched uranium in as little as 30 days. The National Nuclear Security Administration (NNSA) through the Next Generation Safeguards Initiative sponsored a multi-laboratory team to develop an integrated system that provides for detecting scenarios involving 1) diverting an entire declared cylinder for enrichment at a clandestine facility, 2) misusing a declared cylinder at a safeguarded facility, and 3) using an undeclared cylinder at a safeguarded facility. An important objective in developing this integrated system was to improve the timeliness for detecting the cylinder diversion and undeclared production scenarios. Developing this preliminary concept required in-depth analyses of current operational and safeguards practices at conversion, enrichment, and fuel fabrication facilities. The analyses evaluated the processing, movement, and storage of cylinders at the facilities; the movement of cylinders between facilities (including cylinder fabrication); and the misuse of safeguarded facilities.

  7. An Operational System For Monitoring Oil Spills In The Mediterranean Sea: The PROMED System

    Directory of Open Access Journals (Sweden)

    I. KERAMITSOGLOU

    2003-12-01

    Full Text Available The primary objective of this work was the development of an operational system for early detection of oil-spills, monitoring of their evolution, and provision of support to responsible Public Authorities during cleanup operations, based on Remote Sensing and GIS technologies. In case of emergency, the principal characteristics of the oil spill are defined with the aid of a space-borne synthetic aperture radar (SAR. The transport, spreading and dispersion of the oil spill is subsequently simulated on the basis of wind forecasts of the area. The use of thematic maps of protected, fishing and urban areas, and regions of high tourism allows the better assessment of the impact of an oil spill on the areas to be affected in terms of environmental sensitivity. Finally, reports are generated notifying port authorities, the media, and local organizations to be potentially affected by the presence of the oil spill. The pilot site for testing the PROMED System in Greece is the island of Crete.

  8. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  9. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  10. Air Quality Monitoring of the Post-Operative Recovery Room and Locations Surrounding Operating Theaters in a Medical Center in Taiwan

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers. PMID:23573296

  11. Towards operational rainfall monitoring with microwave links from cellular telecommunication networks

    Science.gov (United States)

    Overeem, Aart; Leijnse, Hidde; Uijlenhoet, Remko

    2017-04-01

    The basic principle of rainfall estimation using microwave links is as follows. Rainfall attenuates the electromagnetic signals transmitted from one telephone tower to another. By measuring the received power at one end of a microwave link as a function of time, the path-integrated attenuation due to rainfall can be calculated, which can be converted to average rainfall intensities over the length of a link. Microwave links from cellular communication networks have been proposed as a promising new rainfall measurement technique since one decade. They are particularly interesting for those countries where few surface rainfall observations are available. Yet too date no operational (real-time) link-based rainfall products are available. To advance the process towards operational application and upscaling of this technique, long time series should be analyzed for different networks and climates. Here the potential for long-term large-scale operational rainfall monitoring is demonstrated by utilizing a 2.5-year data set from a cellular communication network. The data set consists of roughly 2,000 links covering the land surface of the Netherlands (35,500 square kilometers). The quality of link rainfall maps is thoroughly quantified by an extensive validation against independent gauge-adjusted radar rainfall maps for, among others, different seasons and extremes. One of the goals is to quantify whether the cellular telecommunication network can yield rainfall maps of comparable quality as those based on automatic rain gauge data (with a density of 1 gauge per 1000 square kilometers). Developing countries will usually have rain gauge networks with a lower density (and little or no weather radars). This helps to assess the possibly added value of link-based rainfall estimates with respect to those from existing rain gauge networks. Moreover, this shows the possibly added value of link rainfall estimates for adjustment of radar rainfall images. The results further confirm

  12. Monitoring millimeter wave stray radiation during ECRH operation at ASDEX Upgrade

    Directory of Open Access Journals (Sweden)

    Wagner D.

    2012-09-01

    Full Text Available Due to imperfection of the single path absorption, ECRH at ASDEX Upgrade (AUG is always accompanied by stray radiation in the vacuum vessel. New ECRH scenarios with O2 and X3 heating schemes extend the operational space, but they have also the potential to increase the level of stray radiation. There are hazards for invessel components. Damage on electric cables has already been encountered. It is therefore necessary to monitor and control the ECRH with respect to the stray radiation level. At AUG a system of Sniffer antennas equipped with microwave detection diodes is installed. The system is part of the ECRH interlock circuit. We notice, however, that during plasma operation the variations of the Sniffer antenna signal are very large. In laboratory measurements we see variations of up to 20 dB in the directional sensitivity and we conclude that an interference pattern is formed inside the copper sphere of the antenna. When ECRH is in plasma operation at AUG, the plasma is acting as a phase and mode mixer for the millimeter waves and thus the interference pattern inside the sphere changes with the characteristic time of the plasma dynamics. In order to overcome the difficulty of a calibrated measurement of the average stray radiation level, we installed bolometer and pyroelectric detectors, which intrinsically average over interference structures due to their large active area. The bolometer provides a robust calibration but with moderate temporal resolution. The pyroelectric detector provides high sensitivity and a good temporal resolution, but it raises issues of possible signal drifts in long pulses.

  13. A computational model for knowledge-driven monitoring of nuclear power plant operators based on information theory

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Man Cheol [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)]. E-mail: charleskim@kaist.ac.kr; Seong, Poong Hyun [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701 (Korea, Republic of)

    2006-03-15

    To develop operator behavior models such as IDAC, quantitative models for the cognitive activities of nuclear power plant (NPP) operators in abnormal situations are essential. Among them, only few quantitative models for the monitoring and detection have been developed. In this paper, we propose a computational model for the knowledge-driven monitoring, which is also known as model-driven monitoring, of NPP operators in abnormal situations, based on the information theory. The basic assumption of the proposed model is that the probability that an operator shifts his or her attention to an information source is proportional to the expected information from the information source. A small experiment performed to evaluate the feasibility of the proposed model shows that the predictions made by the proposed model have high correlations with the experimental results. Even though it has been argued that heuristics might play an important role on human reasoning, we believe that the proposed model can provide part of the mathematical basis for developing quantitative models for knowledge-driven monitoring of NPP operators when NPP operators are assumed to behave very logically.

  14. A computational model for knowledge-driven monitoring of nuclear power plant operators based on information theory

    Energy Technology Data Exchange (ETDEWEB)

    Man Cheol Kim; Poong Hyun Seong [Korea Advanced Institute of Science and Technology, Daejeon (Korea). Department of Nuclear and Quantum Engineering

    2006-03-15

    To develop operator behavior models such as IDAC, quantitative models for the cognitive activities of nuclear power plant (NPP) operators in abnormal situations are essential. Among them, only few quantitative models for the monitoring and detection have been developed. In this paper, we propose a computational model for the knowledge-driven monitoring, which is also known as model-driven monitoring, of NPP operators in abnormal situations, based on the information theory. The basic assumption of the proposed model is that the probability that an operator shifts his or her attention to an information source is proportional to the expected information from the information source. A small experiment performed to evaluate the feasibility of the proposed model show that the predictions made by the proposed model have high correlations with the experimental results. Even though it has been argued that heuristics might play an important role on human reasoning, we believe that the proposed model can provide part of the mathematical basis for developing quantitative models for knowledge-driven monitoring of NPP operators when NPP operators are assumed to behave very logically. (author)

  15. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  16. Cost Effective, Ultra Sensitive Groundwater Monitoring for Site Remediation and Management: Standard Operating Procedures with QA/QC

    Science.gov (United States)

    2015-05-01

    GUIDANCE DOCUMENT Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management: Standard Operating Procedures... Groundwater Monitoring for Site Remediation and Management 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Halden, R.U., Roll, I.B. 5d...DEPLOYMENT WORK As with any groundwater sampling method, the decision to apply the IS2 technology is based on the site characteristics and the type

  17. 48 CFR 852.211-70 - Service data manuals.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Service data manuals. 852... Service data manuals. (a) As prescribed in 811.107(a), insert the following clause: Service Data Manuals (NOV 1984) (a) The successful bidder will supply operation/maintenance (service data) manuals with...

  18. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5650 Manual radionuclide applicator system. (a) Identification. A manual radionuclide applicator system is a manually operated...

  19. 14 CFR 121.141 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 121.141 Section 121... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.141 Airplane flight manual. (a) Each certificate holder shall keep a current approved airplane flight manual for each type...

  20. 46 CFR 154.1809 - Loading and stability manual.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Loading and stability manual. 154.1809 Section 154.1809... stability manual. (a) No person may operate a vessel unless that vessel has on board a loading and stability manual. (b) The loading and stability manual must contain: (1) Information that enables the master...

  1. Survey of Manual Methods of Measurements of Asbestos, Beryllium, Lead, Cadmium, Selenium, and Mercury in Stationary Source Emissions. Environmental Monitoring Series.

    Science.gov (United States)

    Coulson, Dale M.; And Others

    The purpose of this study is to evaluate existing manual methods for analyzing asbestos, beryllium, lead, cadmium, selenium, and mercury, and from this evaluation to provide the best and most practical set of analytical methods for measuring emissions of these elements from stationary sources. The work in this study was divided into two phases.…

  2. Quick-Eye: Examination of Human Performance Characteristics Using Eye Tracking and Manual-Based Control Systems for Monitoring Multiple Displays

    Science.gov (United States)

    2013-03-01

    integration effort to combine eye - tracking technology into a multiple display information system, validation of the resulting system, and results of...studies conducted to determine the performance impact to response time, accuracy, and user workload by using eye - tracking input instead of manual controls to switch control among multiple displays.

  3. "EARTH: The Operators' Manual" - a hybrid model (TV+online+in-person) to effectively communicate climate change science alongside sustainable energy solutions

    Science.gov (United States)

    Haines-stiles, G.; Alley, R. B.; Akuginow, E.

    2011-12-01

    Recent public opinion surveys have found that Americans underestimate the degree of agreement by climate scientists about global warming and climate change, and - despite growing evidence of ice sheet loss, ocean acidification, sea level rise and extreme weather events - believe less in warming trends in 2011 than they did earlier. The issue has become politicized and controversial. "EARTH: The Operators' Manual" is an informal science education project supported by NSF, the National Science Foundation. Its ambitious goal is to use a hybrid mix of broadcast programs appearing on public television and hosted by Penn State geoscientist, Richard Alley, together with on-site outreach events and online resources and tools, to present core climate science in engaging ways, and to combine that presentation of objective research with an overview of sustainable energy solutions. The project's content and communication strategies have been shaped in response to analyses of public opinion such as the SIX AMERICAS study and aim to address common "skeptic" arguments and share essential climate science. Social science research has also found that audiences seem more open to scientific information where the possibility of a positive response is also offered. The first hour-long PBS program aired nationally in April 2011, has since been re-broadcast, and is also available online. Two more programs will air in 2012, and the presentation at the Fall AGU Conference will preview segments from both programs. Five regionally-diverse science centers (in San Diego, Raleigh NC, St. Paul MN, Fort Worth TX and Portland OR) have hosted outreach events, with Richard Alley and other project participants, and will continue with additional activities through summer 2012. The project's website includes video clips, case studies of energy-saving initiatives world-wide and across the USA, plus an interactive "Energy Gauge" inviting users to assess their current Home, Travel, Food, and Goods and

  4. Applying the Science of Science Communication to Climate Change and Clean Energy: Lessons Learned from the NSF- and PBS-supported "Earth: The Operators' Manual"

    Science.gov (United States)

    Haines-Stiles, G.; Akuginow, E.; Sanford, C.

    2014-12-01

    Yale legal scholar and professor of psychology Dan Kahan has criticized the climate change science community for not applying what's known about effective communications strategies to topics with potentially controversial content. "Earth: The Operators' Manual," funded by NSF's Informal Science Education program and appearing on PBS was hosted by Penn State geoscientist Richard Alley. From the initial proposal forward into airing on public television in 2011 and 2012, ETOM aimed to be authoritative and apolitical while still being engaging to general audiences. Based on social scientific insights from project Advisor, Suzanne Moser, and others, ETOM aimed to avoid "climate porn" scare tactics and over-used footage, and to enlist a diverse group of "messengers" in addition to Alley. An important design criterion was to give equal time to clean energy solutions while pulling no punches as to the consensus findings of leading climate scientists. With the ETOM project now completed and final reports submitted to NSF, what results can be shared to inform future efforts? And how did ETOM compare in audience impact with other major media efforts such as Al Gore's "An Inconvenient Truth" or Showtime's more recent "Years of Living Dangerously"? Results reported draw on the external evaluation by Rockman Et Al, and include both quantitative and qualitative data. Key findings are the importance of including Texan ranchers enthusiastic about wind power alongside Navy Admirals adamant that climate change is human-caused and Marines implementing solar energy to reduce casualties incurred while transporting fossil fuels. In-person presentations by Alley and others at science centers served as de facto focus groups for scripting the TV programs, along with actual focus groups convened by Rockman. The 3rd program, ENERGY QUEST USA, documented 5 quite different communities, from Alaska to Forth Worth, Baltimore, Portland and Kansas, all using competition, local values, and economic

  5. Results of a monitoring program of continuous water levels and physical water properties at the Operable Unit 1 area of the Savage Municipal Well Superfund site, Milford, New Hampshire, water years 2000-03

    Science.gov (United States)

    Harte, Philip T.

    2005-01-01

    The Milford-Souhegan glacial-drift (MSGD) aquifer, in south-central New Hampshire, is an important source of industrial, commercial, and domestic water. The MSGD aquifer was also an important source of drinking water for the town of Milford until it was found to contain high concentrations of volatile organic compounds (VOCs) in the Savage and Keyes municipal-supply wells in the early 1980s. A VOC plume was found to cover part of the southwestern half of the MSGD aquifer. In September 1984, the site was designated a Superfund site, called the Savage Municipal Well Superfund site. The primary source area of contaminants was a former tool manufacturing facility (called the OK Tool facility, and now called the Operable Unit 1 (OU1) area) that disposed of solvents at the surface and in the subsurface. The facility was closed in 1987 and removed in 1998. A low-permeability containment barrier wall was constructed and installed in the overburden (MSGD aquifer) in 1998 to encapsulate the highest concentrations of VOCs, and a pump-and-treat remediation facility was also added. Remedial operations of extraction and injection wells started in May 1999. A network of water-level monitoring sites was implemented in water year 2000 (October 1, 1999, through September 30, 2000) in the OU1 area to help assess the effectiveness of remedial operations to mitigate the VOC plume, and to evaluate the effect of the barrier wall and remedial operations on the hydraulic connections across the barrier and between the overburden and underlying bedrock. Remedial extraction and injections wells inside and outside the barrier help isolate ground-water flow inside the barrier and the further spreading of VOCs. This report summarizes both continuous and selected periodic manual measurements of water level and physical water properties (specific conductance and water temperature) for 10 monitoring locations during water years 2000-03. Additional periodic manual measurements of water levels were

  6. In situ radiation test of silicon and diamond detectors operating in superfluid helium and developed for beam loss monitoring

    Science.gov (United States)

    Kurfürst, C.; Dehning, B.; Sapinski, M.; Bartosik, M. R.; Eisel, T.; Fabjan, C.; Rementeria, C. A.; Griesmayer, E.; Eremin, V.; Verbitskaya, E.; Zabrodskii, A.; Fadeeva, N.; Tuboltsev, Y.; Eremin, I.; Egorov, N.; Härkönen, J.; Luukka, P.; Tuominen, E.

    2015-05-01

    As a result of the foreseen increase in the luminosity of the Large Hadron Collider, the discrimination between the collision products and possible magnet quench-provoking beam losses of the primary proton beams is becoming more critical for safe accelerator operation. We report the results of ongoing research efforts targeting the upgrading of the monitoring system by exploiting Beam Loss Monitor detectors based on semiconductors located as close as possible to the superconducting coils of the triplet magnets. In practice, this means that the detectors will have to be immersed in superfluid helium inside the cold mass and operate at 1.9 K. Additionally, the monitoring system is expected to survive 20 years of LHC operation, resulting in an estimated radiation fluence of 1×1016 proton/cm2, which corresponds to a dose of about 2 MGy. In this study, we monitored the signal degradation during the in situ irradiation when silicon and single-crystal diamond detectors were situated in the liquid/superfluid helium and the dependences of the collected charge on fluence and bias voltage were obtained. It is shown that diamond and silicon detectors can operate at 1.9 K after 1×1016 p/cm2 irradiation required for application as BLMs, while the rate of the signal degradation was larger in silicon detectors than in the diamond ones. For Si detectors this rate was controlled mainly by the operational mode, being larger at forward bias voltage.

  7. Sludge Digestion Manual; Handboek Slibgisting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    This manual offers a guideline for developing, designing, optimizing and operating sludge digestion installations based on sewage sludge. It also offers tools for solving operation problems [Dutch] Het Handboek is een leidraad voor het ontwikkelen, ontwerpen, optimaliseren en bedrijven van slibgistingsinstallaties voor zuiveringsslib. Ook geeft het handvatten voor het oplossen van operationele problemen.

  8. 76 FR 39259 - Manual Requirements

    Science.gov (United States)

    2011-07-06

    ... final rule established new requirements for the certification, operation, and maintenance of light-sport... Federal Aviation Administration 14 CFR Part 91 Manual Requirements AGENCY: Federal Aviation Administration... entitled ``Certification of Aircraft and Airmen for the Operation of Light-Sport Aircraft,'' in the Federal...

  9. Neurophysiologic monitoring of mental workload and fatigue during operation of a flight simulator

    Science.gov (United States)

    Smith, Michael E.; Gevins, Alan

    2005-05-01

    In one experiment, EEG recordings were made during a daytime session while 16 well-rested participants performed versions of a PC flight simulator task that were either low, moderate, or high in difficulty. In another experiment, the same subjects repeatedly performed high difficulty versions of the same task during an all night session with total sleep deprivation. Multivariate EEG metrics of cortical activation were derived for frontal brain regions essential for working memory and executive control processes that are presumably important for maintaining situational awareness, central brain regions essential for sensorimotor control, and posterior parietal and occipital regions essential for visuoperceptual processing. During the daytime session each of these regional measures displayed greater activation during the high difficulty task than during the low difficulty task, and degree of cortical activation was positively correlated with subjective workload ratings in these well-rested subjects. During the overnight session, cortical activation declined with time-on-task, and the degree of this decline over frontal regions was negatively correlated with subjective workload ratings. Since participants were already highly skilled in the task, such changes likely reflect fatigue-related diminishment of frontal executive capability rather than practice effects. These findings suggest that the success of efforts to gauge mental workload via proxy cortical activation measures in the context of adaptive automation systems will likely depend on use of user models that take both task demands and the operator"s state of alertness into account. Further methodological development of the measurement approach outlined here would be required to achieve a practical, effective objective means for monitoring transient changes in cognitive brain function during performance of complex real-world tasks.

  10. Monitoring the anaesthetist in the operating theatre - professional competence and patient safety.

    Science.gov (United States)

    Larsson, J

    2017-01-01

    This article about competence and patient safety in anaesthesia was inspired by a statement in the 2015 AAGBI guidelines on monitoring during anaesthesia: 'the presence of an appropriately trained and experienced anaesthetist is important for patient safety during anaesthesia'. The review starts with a structured description of competence, presenting five dimensions of it; the first two dimensions are identical with the two classical attributes of competence, practical skills and theoretical knowledge. Concerning skills, the value of aiming for a high level of proficiency early in a traning programme is pointed out, and deliberate practice is given as an example of a pedagogical model where aiming for excellence is a core idea. For theoretical knowledge, the value of a deep approach to learning physiology and basic sciences is stressed. The third dimension (anaesthetists' non-technical skills), represents skills necessary for good team-work in the operating theatre. The two last dimensions of competence are the understanding of work and intuitive expert knowing. Understanding work means being aware of what the work is about, appreciating the different aspects of the anaesthetist's job. Intuitive expert knowing, lastly, concerns the tacit dimension of knowledge and skills, which enables professional experts to quickly find a working solution for most clinical problems. The final part of the review is about the 'when' and 'how' of competence assessment. The main message is the importance of assessing the competence of clinically active anaesthetists regularly during their whole career. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  11. Operational evaluation of the Mediterranean Monitoring and Forecasting Centre products: implementation and results

    Science.gov (United States)

    Tonani, M.; Nilsson, J. A. U.; Lyubartsev, V.; Grandi, A.; Aydogdu, A.; Azzopardi, J.; Bolzon, G.; Bruschi, A.; Drago, A.; Garau, T.; Gatti, J.; Gertman, I.; Goldman, R.; Hayes, D.; Korres, G.; Lorente, P.; Malacic, V.; Mantziafou, A.; Nardone, G.; Olita, A.; Ozsoy, E.; Pairaud, I.; Pensieri, S.; Perivoliotis, L.; Petelin, B.; Ravaioli, M.; Renault, L.; Sofianos, S.; Sotillo, M. G.; Teruzzi, A.; Zodiatis, G.

    2012-04-01

    A web-based validation platform has been developed at the Istituto Nazionale di Geofisica e Vulcanologia (INGV) for the Near Real Time validation of the MyOcean-Mediterranean Monitoring and Forecasting Centre products (Med-MFC). A network for the collection of the in-situ observations, the nested sub-basin forecasting systems model data (provided by the partners of the Mediterranean Operational Oceanography Network, MOON) and the Sea Surface Temperature (SST) satellite data has been developed and is updated every day with the new available data. The network collects temperature, salinity, currents and sea level data. The validation of the biogeochemical forecast products is done by use of ocean colour satellite data produced for the Mediterranean Sea. All the data are organized in an ad hoc database interfaced with a dedicated software which allows interactive visualizations and statistics (CalVal SW). This tool allows to evaluate NRT products by comparison with independent observations for the first time. The heterogeneous distribution and the scarcity of moored observations reflect with large areas uncovered with measurements. Nevertheless, the evaluation of the forecast at the locations of observations could be very useful to discover sub-regions where the model performances can be improved, thus yielding an important complement to the basin-mean statistics regularly calculated for the Mediterranean MFC products using semi-independent observations.

  12. Monitoring radionuclides in subsurface drinking water sources near unconventional drilling operations: a pilot study.

    Science.gov (United States)

    Nelson, Andrew W; Knight, Andrew W; Eitrheim, Eric S; Schultz, Michael K

    2015-04-01

    Unconventional drilling (the combination of hydraulic fracturing and horizontal drilling) to extract oil and natural gas is expanding rapidly around the world. The rate of expansion challenges scientists and regulators to assess the risks of the new technologies on drinking water resources. One concern is the potential for subsurface drinking water resource contamination by naturally occurring radioactive materials co-extracted during unconventional drilling activities. Given the rate of expansion, opportunities to test drinking water resources in the pre- and post-fracturing setting are rare. This pilot study investigated the levels of natural uranium, lead-210, and polonium-210 in private drinking wells within 2000 m of a large-volume hydraulic fracturing operation--before and approximately one-year following the fracturing activities. Observed radionuclide concentrations in well waters tested did not exceed maximum contaminant levels recommended by state and federal agencies. No statistically-significant differences in radionuclide concentrations were observed in well-water samples collected before and after the hydraulic fracturing activities. Expanded monitoring of private drinking wells before and after hydraulic fracturing activities is needed to develop understanding of the potential for drinking water resource contamination from unconventional drilling and gas extraction activities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Design and Operation of a Radiative Bhabha Luminosity Monitor for CESR-c

    CERN Document Server

    Palmer, Mark A; Crede, Volker; Dooley, Katherine L; Napalitano, James; Rubin, David; Smith, Jeffrey C; Vogel, Helmut

    2005-01-01

    The CLEO-c experiment at the Cornell Electron Storage Ring (CESR) is presently embarking on a multi-year exploration of charm and QCD physics in the 3-5 GeV center-of-mass energy range. In order to facilitate rapid optimization of machine parameters over this energy range, a luminosity monitor based on the measurement of radiative-bhabha photons coming from the CLEO-c interaction point (IP) has been designed and installed in the CESR ring. Key design criteria of the device include: better than 1% statistical measurements of the luminosity with a 1 Hz update rate over the full range of CESR-c operating conditions; bunch-by-bunch measurement capability; a large horizontal aperture to enable measurements under conditions ranging from single-bunch head-on collisions to multi-bunch collisions with a horizontal crossing angle of up to 4~mrad; and, a segmented readout to provide direct information on beam characteristics at the IP. We review the design and performance of this device and discuss its application to ma...

  14. Commissioning and first operation of the pCVD diamond ATLAS Beam Conditions Monitor

    CERN Document Server

    Dobos, D

    2009-01-01

    The main aim of the ATLAS Beam Conditions Monitor is to protect the ATLAS Inner Detector silicon trackers from high radiation doses caused by LHC beam incidents, e.g. magnet failures. The BCM uses in total 16 1x1 cm2 500 μm thick polycrystalline chemical vapor deposition (pCVD) diamond sensors. They are arranged in 8 positions around the ATLAS LHC interaction point. Time difference measurements with sub nanosecond resolution are performed to distinguish between particles from a collision and spray particles from a beam incident. An abundance of the latter leads the BCM to provoke an abort of the LHC beam. A FPGA based readout system with a sampling rate of 2.56 GHz performs the online data analysis and interfaces the results to ATLAS and the beam abort system. The BCM diamond sensors, the detector modules and their readout system are described. Results of the operation with the first LHC beams are reported and results of commissioning and timing measurements (e.g. with cosmic muons) in preparation for first ...

  15. Monitoring of operation with artificial intelligence methods; Betriebsueberwachung mit Verfahren der Kuenstlichen Intelligenz

    Energy Technology Data Exchange (ETDEWEB)

    Bruenninghaus, H. [DMT-Gesellschaft fuer Forschung und Pruefung mbH, Essen (Germany). Geschaeftsbereich Systemtechnik

    1999-03-11

    Taking the applications `early detection of fires` and `reduction of burst of messages` as an example, the usability of artificial intelligence (AI) methods in the monitoring of operation was checked in a R and D project. The contribution describes the concept, development and evaluation of solutions to the specified problems. A platform, which made it possible to investigate different AI methods (in particular artificial neuronal networks), had to be creaated as a basis for the project. At the same time ventilation data had to be acquired and processed by the networks for the classification. (orig.) [Deutsch] Am Beispiel der Anwendungsfaelle `Brandfrueherkennung` und `Meldungsschauerreduzierung` wurde im Rahmen eines F+E-Vorhabens die Einsetzbarkeit von Kuenstliche-Intelligenz-Methoden (KI) in der Betriebsueberwachung geprueft. Der Beitrag stellt Konzeption, Entwicklung und Bewertung von Loesungsansaetzen fuer die genannten Aufgabenstellungen vor. Als Grundlage fuer das Vorhaben wurden anhand KI-Methoden (speziell: Kuenstliche Neuronale Netze -KNN) auf der Grundlage gewonnener und aufbereiteter Wetterdaten die Beziehungen zwischen den Wettermessstellen im Laufe des Wetterwegs klassifiziert. (orig.)

  16. A WEB-BASED SOLUTION TO VISUALIZE OPERATIONAL MONITORING LINUX CLUSTER FOR THE PROTODUNE DATA QUALITY MONITORING CLUSTER

    CERN Document Server

    Mosesane, Badisa

    2017-01-01

    The Neutrino computing cluster made of 300 Dell PowerEdge 1950 U1 nodes serves an integral role to the CERN Neutrino Platform (CENF). It represents an effort to foster fundamental research in the field of Neutrino physics as it provides data processing facility. We cannot begin to over emphasize the need for data quality monitoring coupled with automating system configurations and remote monitoring of the cluster. To achieve these, a software stack has been chosen to implement automatic propagation of configurations across all the nodes in the cluster. The bulk of these discusses and delves more into the automated configuration management system on this cluster to enable the fast online data processing and Data Quality (DQM) process for the Neutrino Platform cluster (npcmp.cern.ch).

  17. GTRI Remote Monitoring System: Training and Operational Needs Assessment Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Day, Debra E.; Fox, Sorcha

    2012-04-20

    The mission of the United States Department of Energy (DOE) National Nuclear Security Administrations (NNSA's) Global Threat Reduction Initiative (GTRI) is to identify, secure, recover and facilitate the disposition of vulnerable nuclear and high-risk radioactive materials around the world that pose a threat to the United States and the international community. The GTRI's unique mission to reduce and protect vulnerable nuclear and radiological materials located at civilian sites worldwide directly addresses recommendations of the 9/11 Commission1, and is a vital part of the President's National Security Strategy and the Global Initiative. The GTRI Remote Monitoring System (RMS) is a standalone security system that includes radiation and tamper alarms, and CCTV; which can be transmitted securely over the Internet to multiple on-site and off-site locations. Through our experiences during installation of the system at 162 sites, plus feedback received from Alarm Response Training course participants, site input to project teams and analysis of trouble calls; indications were that current system training was lacking and inconsistent. A survey was undertaken to gather information from RMS users across the nation, to evaluate the current level of training and determine what if any improvements needed to be made. Additional questions were focused on the operation of the RMS software. The training survey was initially sent electronically to 245 users at the RMS sites and achieved a 37.6% return rate. Analysis of the resulting data revealed that 34.6% of the respondents had not received training or were unsure if they had, despite the fact that vendor engineers provide training at installation of the system. Any training received was referred to as minimal, and brief, not documented, and nothing in writing. 63.7% of respondents said they were either not at all prepared or only somewhat prepared to use the RMS software required to effectively operate the

  18. RCRA and Operational Monitoring (ROM). Multi-Year Program Plan and Fiscal Year 95 Work Plan WBS 1.5.3

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-17

    This document contains information concerning the RCRA and Operational Monitoring Program at Hanford Reservation. Information presented includes: Schedules for ground water monitoring activities, program cost baseline, program technical baseline, and a program milestone list.

  19. Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-11-09

    This report describes environmental monitoring activities at Hanford Reservation. Attention is focused on effluent monitoring and environmental surveillance. All Hanford contractors reviewed potential sources of contamination. A facility effluent monitoring plan was written for each facility with the potential to release significant quantities of hazardous materials, addressing both radiological and nonradiological effluent monitoring. The environmental surveillance program assesses onsite and offsite environmental impacts and offsite human health exposures. The program monitors air, surface water, sediment, agricultural products, vegetation, soil, and wildlife. In addition, independent onsite surveillance is conducted to evaluate the effectiveness of Hanford Site effluent controls in order to comply with applicable environmental standards and regulations.

  20. DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    Kartashov,V.V.; Pratt,W.; Romanov, Y.A.; Samoilov, V.N.; Shestakov, B.A.; Duncan, C.; Brownell, L.; Carbonaro, J.; White, R.M.; Coffing, J.A.

    2009-07-12

    The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Department of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.

  1. 40 CFR Table 5 to Subpart Ppp of... - Process Vents From Batch Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements

    Science.gov (United States)

    2010-07-01

    ... Hazardous Air Pollutant Emissions for Polyether Polyols Production Pt. 63, Subpt. PPP, Table 5 Table 5 to... all instances when monitoring data are not collected—PR. d,e If a base absorbent is used, report all pH values that are below the minimum operating values. If an acid absorbent is used, report all...

  2. 40 CFR 63.4568 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Science.gov (United States)

    2010-07-01

    ... caused in part by poor maintenance or careless operation are not malfunctions. Any period for which the... install a device to monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure... simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and after every...

  3. RingSys-Scheduler User`s manual. Information terminal for town monitoring; Brukermanual for RingSys-Scheduler. Informasjonsterminal for byovervaaking

    Energy Technology Data Exchange (ETDEWEB)

    Marsteen, L.

    1996-02-01

    This report is a User`s manual. It describes RingSys Scheduler, a computer system for continuous display of time series, public information and static pictures. The computer is connected to a host machine via modem and time series, and public information are automatically updated once an hour. RingSys-Scheduler is PC based. It is developed using Excel`s macro language as well as the asynchronous communication program Dynacomm`s script language. 12 figs.

  4. Transatrial access for left atrial pressure (LAP) monitoring line placement in arterial switch operation (ASO) in neonates.

    Science.gov (United States)

    Akhtar, Mohammad Irfan; Hamid, Mohammad; Amanullah, Muneer; Ahsan, Khalid

    2013-11-01

    Left Atrial pressure monitoring is a useful and accurate method to guide Left ventricle filling in the patients who undergo Arterial switch operation for transposition of great arteries. We have used a different technique in three TGA patients for LA pressure monitoring line placement. After cleaning and draping,right internal jugular vein (rt IJV) located through 22G venous cannula, guide wire was put in followed by sliding the 22G x 8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into LA by the operating surgeon during atrial septum repair. The catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72 hrs. LA pressure monitoring is helpful in anticipating LV dysfunction in ASO.

  5. CLF Manual

    Science.gov (United States)

    1991-09-01

    Monitor 33 6.1. Model for Software Evolution 33 6.1.1. Atomicity of a Development Step ;4 6.1.2. Ordering of Development Steps 35 6.2. Bringing a System...Software Evolution Monitor Detvlop is the portion of the CLF systeem which structures the evolution of a system into meaningful units, of work...the changes are relatively easy to undo. Dfvilop protects the user againt dumper process errors as, much as possible. (e.g.. the remote host machine

  6. Response monitoring and action limits: use of ADC numbers in understanding the operational characteristics of the Beckman ASTRA chemistry system.

    Science.gov (United States)

    Kessner, A; Burnett, R W; Bowers, G N

    1981-07-01

    The Beckman ASTRA is a microprocessor-controlled multichannel chemistry analyzer. The output of each module is available to the operator as analog-to-digital conversion (ADC) numbers, which we record during each calibration (Response Monitoring). After so studying three instruments for a total of 33 months, we have established limits for Calibrator ADC numbers that indicate possible operator action (Action Limits). These Action Limits are tighter than the microprocessor's programmed limits, and alert the operator to short- and long-term drift. These tighter limits warn of (a) impending failure of the instrument to calibrate or (b) possible inaccuracies in results for patients. We have instituted changes in preventive maintenance based on our studies of each module's operational characteristics, and have replaced electrodes that failed to meet our Response Monitoring specifications. Response Monitoring and Action Limits based upon ADC numbers have significantly enhanced our understanding of the ASTRA system and thus improved its operational efficiency and analytical reliability. Estimates of precision and accuracy (true value) were satisfactory in comparison to our prior single-channel continuous-flow and flame photometry analytical measurement systems.

  7. Monitoring the clean-up operation of agricultural fields flooded with red mud in Hungary.

    Science.gov (United States)

    Uzinger, Nikolett; Rékási, Márk; Anton, Áron D; Koós, Sándor; László, Péter; Anton, Attila

    2016-12-01

    In the course of the clean-up operation after the red mud inundation in 2010, red mud was removed from the soil surface in places where the layer was more than 5 cm deep. Before its removal, the red mud seeped into the soil. In 2012, soil samples were taken from depths of 0 to 20 and 20 to 40 cm on some of the affected areas. The parameters investigated were pH, organic matter, salt%, and the total and mobile fractions of various elements. The values recorded in 2012 were compared with those measured immediately after the removal of the red mud in 2010 and with the background and clean-up target concentrations. The pH values remained below the designated limit, while the salt content only exhibited values in the weakly salty range on areas at the greatest distance from the dam. In the central part of the inundated area, total Na contents above the 900 mg/kg target value were observed, but the Na content in the 0-20-cm layer generally exhibited a decrease due to leaching. The pH and As concentration also showed a decline on several areas compared with the values recorded in 2010. Total As and Co contents in excess of the target values were recorded on the lowest-lying part of the flooded area, probably because the finest red mud particles were deposited the furthest from the dam, where they seeped into the soil. Nevertheless, the mobility and plant availability of both elements remained moderate. The total contents of both Co and Mo, however, exhibited a significant rise compared with both the background value and the 2010 data. The monitoring of the cleaned-up areas showed that after a 2-year period element concentrations that exceeded the target values and could be attributed to the red mud pollution were only detectable on the lowest-lying areas.

  8. Post-operative monitoring of cortical taurine in patients with subarachnoid hemorrhage: a microdialysis study.

    Science.gov (United States)

    De Micheli, E; Pinna, G; Alfieri, A; Caramia, G; Bianchi, L; Colivicchi, M A; Della Corte, L; Bricolo, A

    2000-01-01

    Intracerebral MD enables the retrieval of endogenous substances from the extracellular fluid (ECF) of the brain and has been demonstrated to be a sensitive technique for early detection of subtle vasospasm-induced neurometabolic abnormalities in patients with subarachnoid hemorrhage (SAH). The aim of this study was to monitor cortical extracellular concentrations of energy metabolism markers, such as glucose and lactate, neurotransmitter amino acids, such as glutamate, aspartate, GABA and taurine to identify any neurochemical patterns of cerebral ischemia. A prospective clinical study was conducted on a group of 16 patients with non-severe SAH operated on within 72 hours after initial bleeding. Following aneurysm clipping, an MD catheter was inserted in the cortical region where vasospasm could be expected to develop, and perfused with artificial CSF at 0.3 microl/min flow rate. Dialysate was collected every 6 hours and then analyzed on High Performance Liquid Cromatography (HPLC) for glucose, lactate, pyruvate, glutamate, aspartate, GABA and taurine. Mean ECF taurine concentrations ranged from 1.4 + 0.7 to 12.3 + 7.8 micromol/l in single patients: global mean value was 5.8 + 3.8 micromol/l. In this series, the highest absolute taurine value was 25.7 micromol/l, observed in a patient who developed clinical and radiological signs of cerebral ischemia. Nine patients presented clinical disturbances related to cerebral vasospasm. In this setting, representing a mild-to-moderate hypoxic condition, MD data demonstrated that lactate is the most sensitive marker of cellular energy imbalance. Increased lactate levels positively correlated with glutamate (P<0.0001), aspartate (P<0.0001), GABA (P<0.0001) and taurine (P<0.0001) concentrations. These results suggest that also in humans increased taurine levels reflect a condition of cellular stress. This study confirms that MD is a sensitive technique to reveal subtle metabolic abnormalities possibly resulting in cell damage.

  9. 14 CFR 91.1427 - CAMP: Manual requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false CAMP: Manual requirements. 91.1427 Section... Operations Program Management § 91.1427 CAMP: Manual requirements. (a) Each program manager who maintains program aircraft under a CAMP must put in the operating manual the chart or description of the...

  10. The internal model: A study of the relative contribution of proprioception and visual information to failure detection in dynamic systems. [sensitivity of operators versus monitors to failures

    Science.gov (United States)

    Kessel, C.; Wickens, C. D.

    1978-01-01

    The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.

  11. Adaptive Contingency Control: Wind Turbine Operation Integrated with Blade Condition Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — We report here on first steps towards integrating systems health monitoring with adaptive contingency controls. In the scenario considered, the adaptive controller...

  12. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    Science.gov (United States)

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  13. Brawley 10MW Geothermal Plant Plant Manual for Southern California Edison Company and Union Oil Company of California: Systems Start-up and Operations, Volume II

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-11-28

    Each system within the facility is considered from an operation viewpoint. There are five subsegments within this operation's viewpoint. Prerequisite conditions, start-up, normal operating, emergency and shutdown.

  14. OASIS User Manual

    CERN Document Server

    Bojtar, L

    2009-01-01

    The OASIS system has been operational for years now. After a long development the project has reached a state where the number of features it provides exceeds largely what most of its users knows about. The author felt it was time to write a user manual explaining all the functionality of the viewer application. This document is a user manual, concentrating on the functionality of the viewer from the user’s point of view. There are already documents available on the project’s web site about the technical aspects at http://project-oasis.web.cern.ch/project-oasis/presentations.htm . There was an attempt to produce a tutorial on the viewer, but it didn’t get much further than the table of contents, that however is well thought. The structure of this user manual follows the same principle, the basic and most often used features are grouped together. Advanced or less often used features are described in a separate chapter. There is a second organizational principle, features belong to different levels: chann...

  15. Asphalt Raking. Instructor Manual. Trainee Manual.

    Science.gov (United States)

    Laborers-AGC Education and Training Fund, Pomfret Center, CT.

    This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…

  16. Quantification of respiratory depression during pre-operative administration of midazolam using a non-invasive respiratory volume monitor

    Science.gov (United States)

    Gonzalez Castro, Luis N.; Mehta, Jaideep H.; Brayanov, Jordan B.; Mullen, Gary J.

    2017-01-01

    Background Pre-operative administration of benzodiazepines can cause hypoventilation—a decrease in minute ventilation (MV)—commonly referred to as “respiratory compromise or respiratory depression.” Respiratory depression can lead to hypercarbia and / or hypoxemia, and may heighten the risk of other respiratory complications. Current anesthesia practice often places patients at risk for respiratory complications even before surgery, as respiratory monitoring is generally postponed until the patient is in the operating room. In the present study we examined and quantified the onset of respiratory depression following the administration of a single dose of midazolam in pre-operative patients, using a non-invasive respiratory volume monitor that reports MV, tidal volume (TV), and respiratory rate (RR). Methods Impedance-based Respiratory Volume Monitor (RVM) data were collected and analyzed from 30 patients prior to undergoing orthopedic or general surgical procedures. All patients received 2.0 mg of midazolam intravenously at least 20 minutes prior to the induction of anesthesia and the effects of midazolam on the patient's respiratory function were analyzed. Results Within 15 minutes of midazolam administration, we noted a significant decrease in both MV (average decrease of 14.3% ± 5.9%, pbenzodiazepines affect primarily TV rather than RR. Such respiratory monitoring data provide the opportunity for individualizing dosing and adjustment of clinical interventions, especially important in elderly patients. With additional respiratory data, clinicians may be able to better identify and quantify respiratory depression, reduce adverse effects, and improve overall patient safety. PMID:28235069

  17. Operation and performance of a National Monitoring Network for Radioactivity in Food

    NARCIS (Netherlands)

    Brandhoff, P.N.; Bourgondiën, van M.J.; Onstenk, C.G.M.; Vos van Avezathe, A.; Peters, R.J.B.

    2016-01-01

    In the Netherlands, the EU-mandated nationwide monitoring programme and emergency response plan for radioactivity in food is implemented by RIKILT (the Dutch institute for food safety) by means of the National Monitoring Network for Radioactivity in Food (LMRV). The LMRV consists of 48 individual

  18. Application of the quantitative oil monitoring to analysing the operating condition of marine machinery

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Based on the data of Fourier transform infra-red (FTIR) spectroscopy, spectrometric oilanalysis (SOA) and other routine methods, the experiment of oil monitoring for steering propellersis discussed. The experiment demonstrates the FTIR spectroscopy can rapidly and easily obtainthe results in laboratory analysis, and combine with spectrometer oil analysis, complementary in-formation is most effective to condition monitoring of marine machinery.

  19. Operation and performance of a National Monitoring Network for Radioactivity in Food

    NARCIS (Netherlands)

    Brandhoff, P.N.; Bourgondiën, van M.J.; Onstenk, C.G.M.; Vos van Avezathe, A.; Peters, R.J.B.

    2016-01-01

    In the Netherlands, the EU-mandated nationwide monitoring programme and emergency response plan for radioactivity in food is implemented by RIKILT (the Dutch institute for food safety) by means of the National Monitoring Network for Radioactivity in Food (LMRV). The LMRV consists of 48 individual

  20. 40 CFR 63.2269 - What are my monitoring installation, operation, and maintenance requirements?

    Science.gov (United States)

    2010-07-01

    ... Composite Wood Products Initial Compliance Requirements § 63.2269 What are my monitoring installation... moisture monitoring. For each furnish or veneer moisture meter, you must meet the requirements in... in the 25 to 35 percent (dry basis) moisture content range. For veneer redryers, use a...

  1. Network simulation experiments manual

    CERN Document Server

    Aboelela, Emad

    2011-01-01

    Network Simulation Experiments Manual, Third Edition, contains simulation-based experiments to help students and professionals learn about key concepts in computer networking. The simulation approach provides a virtual environment for a wide range of desirable features, such as modeling a network based on specified criteria and analyzing its performance under different scenarios. The experiments include the basics of using OPNET IT Guru Academic Edition; operation of the Ethernet network; partitioning of a physical network into separate logical networks using virtual local area networks (V

  2. TIA Software User's Manual

    Science.gov (United States)

    Cramer, K. Elliott; Syed, Hazari I.

    1995-01-01

    This user's manual describes the installation and operation of TIA, the Thermal-Imaging acquisition and processing Application, developed by the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center, Hampton, Virginia. TIA is a user friendly graphical interface application for the Macintosh 2 and higher series computers. The software has been developed to interface with the Perceptics/Westinghouse Pixelpipe(TM) and PixelStore(TM) NuBus cards and the GW Instruments MacADIOS(TM) input-output (I/O) card for the Macintosh for imaging thermal data. The software is also capable of performing generic image-processing functions.

  3. Results of a Joint Navy/Air Force Operational Test to Evaluate USAF integrated Maintenance Information Systems (IMIS), Interactive Electronic Technical Manual (IETM) Technology Applied to the F/A-18 Aircraft

    Science.gov (United States)

    1993-06-14

    8217 RATING OF EFFECNIVENESS OF IFMT/PMA FEATURES ... 68 5.2.1 Physical Features of the ErMPMA Combination ................. 69 5.2.2 Softwre -Operational...SGraphics Intel 87871-based hybrid SInterfaces M.STD 1553, RS 232C, 1.3 M~ s channel hopping radio Powr Supply 16.5 Volt Yardney Silverell battery pack...Technical Manual (IETM) 3 The term IETM [see ref. 12] has been defined , for example, in ref. 2, as follows: A Technical Nanual, prepared (authored) by

  4. Development of a web-based monitoring system using operation parameters for the main component in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Son, Dong Chan; An, Kung Il; Hong, Suk Young; Lee, Jeong Soo; Jung, Duk Jin; Shin, Sun Hee; Son, So Hee [Daesang Information Technology Co., Ltd., Seoul (Korea, Republic of)

    2004-02-15

    The frequency of the damage is increasing, which is caused by the fatigue, according to the increase of running of nuclear power plants. So we need to acquire the reliance of design data to estimate the fatigue and damage of major machinery that might happen as time-dependent crack growth characterization. The research is focused on keeping operating record of nuclear power plants about major machinery which consists of a nuclear reactor pressure boarder on each excessive operating condition including normal operating and extraordinary operating by estimating fracture mechanical movements on real time and fatigue about major nuclear power plants machinery, which are acquired the pressure and temperature data. For further details about the scope and contents of R and D are following. Development of H/W that is necessary to acquire operating real time data of heating and hydraulic power. Selection of a safety variable about major system by each type (the four NPP, all unit). Communication protocol development for connecting between CARE system data base server and fatigue monitoring system data base server. Development of connecting database for controlling and storing of heating and hydraulic power operating data. Real time monitoring system development based on Web using JAVA.

  5. Monitoring of EOR operations by electrical prospecting. 2; Denki tansaho ni yoru sekiyu kyosei kaishuho no monitoring. 2

    Energy Technology Data Exchange (ETDEWEB)

    Ushijima, K.; Mizunaga, H.; Tanaka, T.; Masuda, K. [Kyushu University, Fukuoka (Japan). Faculty of Engineering; Tamagawa, T. [Japex Jeoscience Institute, Tokyo (Japan)

    1996-10-01

    Fluid flow tomography (FFT) was applied to monitor the behavior of underground fluid in steam enhanced oil recovery (EOR) for oil sand reservoirs. FFT uses electrode arrangement of a mise-a-la-masse method, and continuously measures time variation in charged and spontaneous potential at various surface points to obtain realtime the images of underground seepage flow. It continuously measures ground surface potentials of 120 channels at intervals of 2s by applying alternative DC between a casing pipe and distant current electrode. It separates charged and spontaneous potential components, and converts them into time series data. It estimates the time and spacial distributions of seepage flow from time variation in spontaneous potential. It determines the change rate distribution of time-sliced apparent resistivity from charged potential to estimate the scale and area of seepage flow. As the experimental result, positive and negative electrodes in the change rate distribution were observed, and the direction connecting each electrode agreed with that of resistivity anomaly. FFT could observe realtime time variation in apparent resistivity due to steam injection. 9 refs., 7 figs.

  6. Guidelines for use of water-quality monitors

    Science.gov (United States)

    Gordon, A. Brice; Katzenbach, Max S.

    1983-01-01

    This manual contains methods and procedures used by the U.S. Geological Survey (USGS) for collecting specific conductance, dissolved oxygen, water temperature, and pH data for ground water, streams, lakes, reservoirs, and estuaries by means of permanently installed, continuously recording, water quality monitors. The topics discussed include the selection of monitoring sites, selection and installation of shelters and equipment, and standard methods of calibration, operation and maintenance of water-quality monitors.

  7. Two simple multivariate procedures for monitoring planetary gearboxes in non-stationary operating conditions

    Science.gov (United States)

    Zimroz, Radoslaw; Bartkowiak, Anna

    2013-07-01

    This paper deals with the diagnostics of planetary gearboxes under nonstationary operating conditions. In most diagnostics applications, energy of vibration signals (calculated directly from time series or extracted from spectral representation of signal) is used. Unfortunately energy based features are sensitive to load conditions and it makes diagnostics difficult. In this paper we used energy based 15D data vectors (namely spectral amplitudes of planetary mesh frequency and its harmonics) in order to investigate if it is possible to improve diagnostics efficiency in comparison to previous, one dimensional, approaches proposed for the same problem. Two multivariate methods, Principal Component Analysis (PCA) and Canonical Discriminant Analysis (CDA), were used as techniques for data analysis. We used these techniques in order to investigate dimensionality of the data and to visualize data in 3D and 2D spaces in order to understand data behavior and assess classification ability. As a case study the data from two planetary gearboxes used in complex mining machines (one in bad condition and the other in good condition) were analyzed. For these two machines more than 2000 15D vectors were acquired. It should be noted that due to non-stationarity of loading conditions, previous diagnostics results obtained using other techniques were moderately good (ca. 80% recognition efficiency); however there is still some need to improve diagnostics classification ability. After application of the proposed approaches it was found that the entire data could be reduced to 2 dimensions whereby data instances became visible and a good discriminant function (characterized by a misclassification rate of .0023, i.e. only 5 erroneous classifications for a total of 2183 instances) could be derived. This paper suggests a novel way for condition monitoring of planetary gearboxes based on multivariate statistics. The emphasis is put on the algebraic and geometric interpretations of the PCA

  8. 49 CFR 240.129 - Criteria for monitoring operational performance of certified engineers.

    Science.gov (United States)

    2010-10-01

    ... employs the skills to safely operate locomotives and/or trains, including the proper application of the... compliance with provisions of the railroad's operating rules, timetable or other mandatory directives that... operating rules, timetable or other mandatory directives violation of which by engineers were cited by...

  9. Operational GPS Imaging System at Multiple Scales for Earth Science and Monitoring of Geohazards

    Science.gov (United States)

    Blewitt, Geoffrey; Hammond, William; Kreemer, Corné

    2016-04-01

    Toward scientific targets that range from slow deep Earth processes to geohazard rapid response, our operational GPS data analysis system produces smooth, yet detailed maps of 3-dimensional land motion with respect to our Earth's center of mass at multiple spatio-temporal scales with various latencies. "GPS Imaging" is implemented operationally as a back-end processor to our GPS data processing facility, which uses JPL's GIPSY OASIS II software to produce positions from 14,000 GPS stations in ITRF every 5 minutes, with coordinate precision that gradually improves as latency increases upward from 1 hour to 2 weeks. Our GPS Imaging system then applies sophisticated signal processing and image filtering techniques to generate images of land motion covering our Earth's continents with high levels of robustness, accuracy, spatial resolution, and temporal resolution. Techniques employed by our GPS Imaging system include: (1) similarity transformation of polyhedron coordinates to ITRF with optional common-mode filtering to enhance local transient signal to noise ratio, (2) a comprehensive database of ~100,000 potential step events based on earthquake catalogs and equipment logs, (3) an automatic, robust, and accurate non-parametric estimator of station velocity that is insensitive to prevalent step discontinuities, outliers, seasonality, and heteroscedasticity; (4) a realistic estimator of velocity error bars based on subsampling statistics; (5) image processing to create a map of land motion that is based on median spatial filtering on the Delauney triangulation, which is effective at despeckling the data while faithfully preserving edge features; (6) a velocity time series estimator to assist identification of transient behavior, such as unloading caused by drought, and (7) a method of integrating InSAR and GPS for fine-scale seamless imaging in ITRF. Our system is being used to address three main scientific focus areas, including (1) deep Earth processes, (2

  10. The role of Environmental Health System air quality monitors in Space Station Contingency Operations

    Science.gov (United States)

    Limero, Thomas F.; Wilson, Steve; Perlot, Susan; James, John

    1992-01-01

    This paper describes the Space Station Freedom (SSF) Environmental Health System's air-quality monitoring strategy and instrumentation. A two-tier system has been developed, consisting of first-alert instruments that warn the crew of airborne contamination and a volatile organic analyzer that can identify volatile organic contaminants in near-real time. The strategy for air quality monitoring on SSF is designed to provide early detection so that the contamination can be confined to one module and so that crew health and safety can be protected throughout the contingency event. The use of air-quality monitors in fixed and portable modes will be presented as a means of following the progress of decontamination efforts and ensuring acceptable air quality in a module after an incident. The technology of each instrument will be reviewed briefly; the main focus of this paper, however, will be the use of air-quality monitors before, during, and after contingency incidents.

  11. Operational blueprint for inventory and monitoring on National Wildlife Refuges : Adapting to environmental change

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This blueprint describes how the National Wildlife Refuge System will initially implement a nationally coordinated program to support inventorying and monitoring...

  12. MONITORING OF ANTICOAGULATION IN APROTININ-TREATED PATIENTS DURING HEART OPERATION

    NARCIS (Netherlands)

    TABUCHI, N; NJO, TL; TIGCHELAAR, [No Value; HUYZEN, RJ; BOONSTRA, PW; VANOEVEREN, W

    1994-01-01

    Since aprotinin has become extensively used during cardiopulmonary bypass the maintenance of safe anticoagulation is a concern. Aprotinin affects anticoagulation measurement by the activated clotting time. Therefore, a reliable new measurement is needed to monitor anticoagulation during cardiopulmon

  13. Use of the Operational Air Quality Monitor (AQM) for In-Flight Water Testing Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Currently, the Air Quality Monitor (AQM) on-board ISS provides specific information for a number of target compounds in the air. However, there is a significant...

  14. US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Outdoor Air

    Science.gov (United States)

    The procedure described is intended for monitoring continuously and simultaneously outdoor air quality parameters that are most commonly associated with indoor air quality: the concentrations of carbon dioxide (CO2) and carbon monoxide (CO), temperature, nd relative humidity (RH).

  15. GlobVolcano pre-operational services for global monitoring active volcanoes

    Science.gov (United States)

    Tampellini, Lucia; Ratti, Raffaella; Borgström, Sven; Seifert, Frank Martin; Peltier, Aline; Kaminski, Edouard; Bianchi, Marco; Branson, Wendy; Ferrucci, Fabrizio; Hirn, Barbara; van der Voet, Paul; van Geffen, J.

    2010-05-01

    The GlobVolcano project (2007-2010) is part of the Data User Element programme of the European Space Agency (ESA). The project aims at demonstrating Earth Observation (EO) based integrated services to support the Volcano Observatories and other mandate users (e.g. Civil Protection) in their monitoring activities. The information services are assessed in close cooperation with the user organizations for different types of volcano, from various geographical areas in various climatic zones. In a first phase, a complete information system has been designed, implemented and validated, involving a limited number of test areas and respective user organizations. In the currently on-going second phase, GlobVolcano is delivering pre-operational services over 15 volcanic sites located in three continents and as many user organizations are involved and cooperating with the project team. The set of GlobVolcano offered EO based information products is composed as follows: Deformation Mapping DInSAR (Differential Synthetic Aperture Radar Interferometry) has been used to study a wide range of surface displacements related to different phenomena (e.g. seismic faults, volcanoes, landslides) at a spatial resolution of less than 100 m and cm-level precision. Permanent Scatterers SAR Interferometry method (PSInSARTM) has been introduced by Politecnico of Milano as an advanced InSAR technique capable of measuring millimetre scale displacements of individual radar targets on the ground by using multi-temporal data-sets, estimating and removing the atmospheric components. Other techniques (e.g. CTM) have followed similar strategies and have shown promising results in different scenarios. Different processing approaches have been adopted, according to data availability, characteristic of the area and dynamic characteristics of the volcano. Conventional DInSAR: Colima (Mexico), Nyiragongo (Congo), Pico (Azores), Areanal (Costa Rica) PSInSARTM: Piton de la Fournaise (La Reunion Island

  16. Operational benefits obtained by implementing a remote monitoring and control system at CEGAS (Gas Company of Ceara, Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Rui C.O. [Companhia de Gas do Ceara (CEGAS), Fortaleza, CE (Brazil); Zamponha, Rogerio S. [SOFTBRASIL, Sao Paulo, SP (Brazil)

    2009-07-01

    CEGAS (Gas Company of Ceara) recently implemented an automated remote monitoring and control system at the Natural Gas Stations located within the city of Fortaleza. The main purposes to implement the project were to install a better operational platform, allowing CEGAS to analyze its operational conditions and to measure customer's consumption in real time. The data communication infra-structure chosen was GPRS/GSM, due to it's low deployment cost and coverage availability. The first phase of the project comprised 50 vehicular natural gas stations. The project was successfully installed, and became the 1{sup st} project at this type to run efficiently over a GPRS infra-structure in Brazil for gas monitoring, with reliable control and data communication. This document intends to present the reasons that lead CEGAS to invest in such a system, the technology deployed and the benefits achieved. (author)

  17. Results of Continuous Load Cell Monitoring Field Trial for UF6 Withdrawals at an Operating Industrial Plant

    Energy Technology Data Exchange (ETDEWEB)

    Krichinsky, Alan M [ORNL; Bell, Lisa S [ORNL; Conchewski, Curtis A [ORNL; Peters, Benjamin R [ORNL; Pickett, Chris A [ORNL; Richardson, Dave [ORNL; Rowe, Nathan C [ORNL; Younkin, James R [ORNL

    2010-01-01

    Continuous load cell monitoring (CLCM) has been implemented and tested for use as a safeguards tool during a 2009 field trial in an operating UF6 transfer facility. The transfer facility is part of the Portsmouth Gaseous Diffusion Plant in Piketon, Ohio, operated by the United States Enrichment Corporation. During the field trial, two process scales for UF{sub 6} cylinders were continuously monitored for a 6-month period as cylinders were being filled. The collected CLCM data were used in testing an event processor serving as a filter for highlighting measurements representing significant operational activities that are important in verifying declared operations. The collection of CLCM data, coupled with rules-based event processing, can provide inspectors with knowledge of a facility's feed and withdrawal activities occurring between site visits. Such process knowledge promises to enhance the effectiveness of safeguards by enabling inspectors to quantitatively compare declared activities directly with process measurements. Selected results of the field trial and event processing will be presented in the context of their value to an independent inspector and a facility operator.

  18. Hoisting and rigging manual: Uncontrolled document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-01

    This document is a draft copy of a Hoisting and Rigging Manual for the Department of Energy. The manual is divided into ten chapters. The chapter titles follow: terminology and definitions; operator training and qualification; overhead and gantry cranes; mobile cranes; forklift trucks; hoists; hooks; wire rope, slings, and rigging accessories; construction hoisting and rigging equipment requirements; references.

  19. The American University Hotline: Manual for Trainers.

    Science.gov (United States)

    Krieger, Howard; And Others

    The philosophy, rationale, and specific training procedures of the American University Hotline are detailed in this trainer's manual. The manual provides a step-by-step discussion of training procedures implemented in a student-operated university hotline telephone service. The training package, widely disseminated over the past six years, has…

  20. 49 CFR 236.751 - Interlocking, manual.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Interlocking, manual. 236.751 Section 236.751 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Interlocking, manual. An arrangement of signals and signal appliances operated from an interlocking machine...