WorldWideScience

Sample records for monitor oblique high-frequency

  1. Corrosion monitoring using high-frequency guided waves

    Science.gov (United States)

    Fromme, P.

    2016-04-01

    Corrosion can develop due to adverse environmental conditions during the life cycle of a range of industrial structures, e.g., offshore oil platforms, ships, and desalination plants. Generalized corrosion leading to wall thickness loss can cause the reduction of the strength and thus degradation of the structural integrity. The monitoring of corrosion damage in difficult to access areas can be achieved using high frequency guided waves propagating along the structure from accessible areas. Using standard ultrasonic wedge transducers with single sided access to the structure, guided wave modes were selectively generated that penetrate through the complete thickness of the structure. The wave propagation and interference of the different guided wave modes depends on the thickness of the structure. Laboratory experiments were conducted for wall thickness reduction due to milling of the steel structure. From the measured signal changes due to the wave mode interference the reduced wall thickness was monitored. Good agreement with theoretical predictions was achieved. The high frequency guided waves have the potential for corrosion damage monitoring at critical and difficult to access locations from a stand-off distance.

  2. Magnetic anisotropy and high-frequency property of flexible FeCoTa films obliquely deposited on a wrinkled topography.

    Science.gov (United States)

    Li, Jincai; Zhan, Qingfeng; Zhang, Shuanglan; Wei, Jinwu; Wang, Jianbo; Pan, Minjie; Xie, Yali; Yang, Huali; Zhou, Zheng; Xie, Shuhong; Wang, Baomin; Li, Run-Wei

    2017-06-06

    We investigated the magnetic anisotropy and the high-frequency property of flexible Fe60Co26Ta14 (FeCoTa) thin films obtained by oblique sputtering onto a wrinkled surface. The sinuously wrinkled topography is produced by growing Ta layer on a pre-strained polydimethylsiloxane (PDMS) membrane. Due to the enhanced effect of shadowing, the oblique deposition of FeCoTa layer gives rise to a shift of wrinkle peak towards the incident atomic flux. With increasing the PDMS pre-strain or increasing the oblique sputtering angle, both the uniaxial magnetic anisotropy and the ferromagnetic resonance frequency of FeCoTa films are enhanced, but the initial permeability decreases. The magnetization reversal mechanism of wrinkled FeCoTa films can be interpreted by a two-phase model composed of both coherent rotation and domain wall nucleation. With the enhancement of uniaxial magnetic anisotropy, the domain wall nucleation becomes pronounced in FeCoTa films.

  3. Oblique echoes at unusually high frequencies in MARSIS-AIS measurements of the topside ionosphere of Mars

    Science.gov (United States)

    Fallows, Kathryn J.; Withers, Paul; Morgan, David

    2016-10-01

    The topside plasma density measurements from the Mars Advanced Radar for Subsurface and Ionosphere Sounding (MARSIS) instrument on the Mars Express orbiter have been invaluable for studying the influence of the crustal magnetic fields on the distribution of plasma in the Mars ionosphere. A common feature, especially in the southern crustal field region, is an "oblique echo," or an off-nadir reflection consistent with the spacecraft passing by, or directly above, a localized region with a sharp gradient in electron density. These are often interpreted as regions where the ionosphere is heated by the solar wind fields and plasma which penetrate the ionosphere along vertical field lines.We present a subset of these oblique echoes which are characterized by reflections at frequencies much higher than those from the nadir ionosphere. If these are interpreted in the same way as typical return signals, where the frequency of the reflected signal is assumed to be the plasma frequency at the point of reflection, then these may be the highest plasma densities reported to date at Mars. In two cases, reflections are detected at the maximum sounding frequency of the instrument, 5.5 MHz, which corresponds to electron densities of 3.75x105 cm-3.These features are associated with strong, vertical magnetic fields, as expected for typical oblique echoes. However, they are only observed in regions where there is also an above-average likelihood of the field lines being open to the solar wind. This is consistent with the interpretation that these cusp-like regions can allow for interaction with the solar wind, but it is not yet clear whether these are an extreme case of "typical" oblique echoes, or whether these high-frequency echoes are caused by a unique physical process or observation geometry.

  4. Soft magnetic properties and high frequency characteristics of FeM (M = B, Hf, Zr) and pure Fe films fabricated by oblique deposition

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chengcheng; Zhang, Chao; Wang, Fenglong; Zhao, Zhong; Jiang, Changjun; Xue, Desheng [Lanzhou University, Key Laboratory for Magnetism and Magnetic Materials of Ministry of Education, Lanzhou (China); Lanzhou University, Key Laboratory of Special Function Materials and Structure Design of Ministry of Education, Lanzhou (China)

    2015-09-15

    To improve the high-frequency properties of Fe-based thin films, doped and pure Fe thin films were obliquely deposited on Si (100) substrate by RF-magnetron sputtering. Vibrating sample magnetometer (VSM) measurements show obvious in-plane uniaxial magnetic anisotropy in both doped and pure Fe thin films, and enhancement effects of doping on Soft magnetic properties were also observed. Microwave permeability measurements indicate that the resonance frequency and permeability of pure Fe films are much larger than those of doped Fe thin films. Damping factors of Fe thin films deposited at different oblique angles were further investigated. (orig.)

  5. Sensors for High Frequency monitoring of cyanoHABs and cyanotoxin production

    Science.gov (United States)

    The use of sensors in environmental monitoring is an area of constant evolution. As monitoring needs present themselves, technology development follows. Here, the use of high frequency data to monitor and predict HABs is presented illustrating the successful use of technology a...

  6. High frequency bulk resonators for bio/chemical diagnostics and monitoring applications

    DEFF Research Database (Denmark)

    Cagliani, Alberto

    In the environmental monitoring eld there is a vast variety of possible applications for microfabricated MEMS sensors. As an example, a network of miniaturized sensors could detect toxic gases, harmful airbornes, explosives in air or, in liquid, monitor the quality of drinking water...... is by monitoring the target mass, that is continuously deposited or removed from the sensor's surface, while the sensor's structure vibrates in resonance. This thesis presents the development of MEMS mass sensors based on mechanical microresonators in the very high frequency range 12-132 MHz. This devices can...

  7. High frequency guided waves for hidden fatigue crack growth monitoring in multi-layer aerospace structures

    Science.gov (United States)

    Chan, Henry; Fromme, Paul

    2015-03-01

    Varying loading conditions of aircraft structures result in stress concentration at fastener holes, where multi-layered components are connected, possibly leading to the development of fatigue cracks. High frequency guided waves propagating along the structure allow for the non-destructive testing of such components, e.g., aircraft wings. However, the sensitivity for the detection of small, potentially hidden, fatigue cracks has to be ascertained. The type of multi-layered model structure investigated consists of two adhesively bonded aluminium plate-strips. Fatigue experiments were carried out. The sensitivity of the high frequency guided wave modes to monitor fatigue crack growth at a fastener hole during cyclic loading was investigated, using both standard pulse-echo equipment and laser interferometry. The sensitivity and repeatability of the measurements were ascertained, having the potential for fatigue crack growth monitoring at critical and difficult to access fastener locations from a stand-off distance.

  8. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review.

    Science.gov (United States)

    Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva

    2016-07-01

    The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.

  9. An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-05-01

    Full Text Available Ultra-high-frequency (UHF partial discharge (PD online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new method, namely a level scanning method. The intelligent sensor can directly acquire the statistical characteristic quantities and is characterized by low cost, few data to output and transmit, Ethernet functionality, and small size for easy installation. The prototype of an intelligent sensor was made. Actual UHF PD experiments with three typical artificial defect models of power transformers were carried out in a laboratory, and the waveform recording method and intelligent sensor proposed were simultaneously used for UHF PD measurement for comparison. The results show that the proposed intelligent sensor is qualified for the UHF PD online monitoring of power transformers. Additionally, three methods to improve the performance of intelligent sensors were proposed according to the principle of the level scanning method.

  10. Monitoring of hidden damage in multi-layered aerospace structures using high-frequency guided waves

    Science.gov (United States)

    Semoroz, A.; Masserey, B.; Fromme, P.

    2011-04-01

    Aerospace structures contain multi-layered components connected by fasteners, where fatigue cracks and disbonds or localized lack of sealant can develop due to cyclic loading conditions and stress concentration. High frequency guided waves propagating along such a structure allow for the efficient non-destructive testing of large components, such as aircraft wings. The type of multi-layered model structure investigated in this contribution consists of two aluminium plates adhesively bonded with an epoxy based sealant layer. Using commercially available transducer equipment, specific high frequency guided ultrasonic wave modes that penetrate through the complete thickness of the structure were excited. The wave propagation along the structure was measured experimentally using a laser interferometer. Two types of hidden damage were considered: a localized lack of sealant and small surface defects in the metallic layer facing the sealant. The detection sensitivity using standard pulse-echo measurement equipment has been quantified and the detection of small hidden defects from significant stand-off distances has been shown. Fatigue experiments were carried out and the potential of high frequency guided waves for the monitoring of fatigue crack growth at a fastener hole during cyclic loading was discussed.

  11. High-frequency guided ultrasonic waves to monitor corrosion thickness loss

    Science.gov (United States)

    Fromme, Paul; Bernhard, Fabian; Masserey, Bernard

    2017-02-01

    Corrosion due to adverse environmental conditions can occur for a range of industrial structures, e.g., ships and offshore oil platforms. Pitting corrosion and generalized corrosion can lead to the reduction of the strength and thus degradation of the structural integrity. The nondestructive detection and monitoring of corrosion damage in difficult to access areas can be achieved using high frequency guided ultrasonic waves propagating along the structure. Using standard ultrasonic transducers with single sided access to the structure, the two fundamental Lamb wave modes were selectively generated simultaneously, penetrating through the complete thickness of the structure. The wave propagation and interference of the guided wave modes depends on the thickness of the structure. Numerical simulations were performed using a 2D Finite Difference Method (FDM) algorithm in order to visualize the guided wave propagation and energy transfer across the plate thickness. Laboratory experiments were conducted and the wall thickness reduced initially uniformly by milling of the steel structure. Further measurements were conducted using accelerated corrosion in salt water. From the measured signal change due to the wave mode interference, the wall thickness reduction was monitored and good agreement with theoretical predictions was achieved. Corrosion can lead to non-uniform thickness reduction and the influence of this on the propagation of the high frequency guided ultrasonic waves was investigated. The wave propagation in a steel specimen with varying thickness was measured experimentally and the influence on the wave propagation characteristics quantified.

  12. High-frequency nutrient monitoring to infer seasonal patterns in catchment source availability, mobilisation and delivery.

    Science.gov (United States)

    Bende-Michl, Ulrike; Verburg, Kirsten; Cresswell, Hamish P

    2013-11-01

    To explore the value of high-frequency monitoring to characterise and explain riverine nutrient concentration dynamics, total phosphorus (TP), reactive phosphorus (RP), ammonium (NH4-N) and nitrate (NO3-N) concentrations were measured hourly over a 2-year period in the Duck River, in north-western Tasmania, Australia, draining a 369-km(2) mixed land use catchment area. River discharge was observed at the same location and frequency, spanning a wide range of hydrological conditions. Nutrient concentrations changed rapidly and were higher than previously observed. Maximum nutrient concentrations were 2,577 μg L(-1) TP, 1,572 μg L(-1) RP, 972 μg L(-1) NH₄-N and 1,983 μg L(-1) NO₃-N, respectively. Different nutrient response patterns were evident at seasonal, individual event and diurnal time scales-patterns that had gone largely undetected in previous less frequent water quality sampling. Interpretation of these patterns in terms of nutrient source availability, mobilisation and delivery to the stream allowed the development of a conceptual model of catchment nutrient dynamics. Functional stages of nutrient release were identified for the Duck River catchment and were supported by a cluster analysis which confirmed the similarities and differences in nutrient responses caused by the sequence of hydrologic events: (1) a build-up of nutrients during periods with low hydrologic activity, (2) flushing of readily available nutrient sources at the onset of the high flow period, followed by (3) a switch from transport to supply limitation, (4) the accessibility of new nutrient sources with increasing catchment wetness and hydrologic connectivity and (5) high nutrient spikes occurring when new sources become available that are easily mobilised with quickly re-established hydrologic connectivity. Diurnal variations that could be influenced by riverine processes and/or localised point sources were also identified as part of stage (1) and during late recession of some of

  13. Efficacy of intradermal mesotherapy in cellulite reduction - Conventional and high-frequency ultrasound monitoring results.

    Science.gov (United States)

    Sylwia, Malinowska; Krzysztof, Mlosek Robert

    2017-10-01

    Cellulite affects the majority of women and is an unacceptable cosmetic defect. Therefore, effective methods for cellulite reduction are being sought. Intradermal mesotherapy is one of such methods. The aim of the study was to assess the efficacy of intradermal mesotherapy in cellulite reduction, using conventional and high-frequency ultrasound. Twenty-one women with cellulite underwent a series of intradermal mesotherapy procedures. The following parameters were assessed: thickness of epidermis, dermis and hypodermis, echogenicity of dermis and the surface area of serrated hypodermis-dermis junction. Furthermore, the thigh circumference was measured; body mass index and cellulite severity were assessed based on photographs using Nürnberger-Müller's scale. Intradermal mesotherapy reduced severity of cellulite. The surface area of serrated hypodermis-dermis junction and hypodermis thickness decreased significantly as compared to baseline. Cellulite reduction was also confirmed by palpation, decreased thigh circumference and the Nürnberger-Müller's grade. There were no statistically significant changes in epidermis or dermis thickness, body weight and the BMI. Intradermal mesotherapy offers effective cellulite reduction. It is a simple and safe treatment, which makes it popular. Further research in mesotherapy is essential due to a limited number of published studies. Ultrasound is a useful method to monitor intradermal mesotherapy and assess its efficacy.

  14. The role of high frequency monitoring in understanding nutrient pollution processes to address catchment management issues

    Science.gov (United States)

    Quinn, Paul; Jonczyk, Jennine; Owen, Gareth; Barber, Nick; Adams, Russell; ODonnell, Greg; EdenDTC Team

    2015-04-01

    The process insights afforded to catchment scientists through the availability of high frequency time series of hydrological and nutrient pollution datasets are invaluable. However, the observations reveal both good and bad news for the WFD. Data for flow, N, P and sediment (taken at 30 min intervals) from the River Eden Demonstration Test Catchment and several other detailed UK studies, will be used to discuss nutrient fluxes in catchments between 1km2 and 10km2. Monitoring of the seasonal groundwater status and the forensic analysis of numerous storm events have identified dominant flow pathways and nutrient losses. Nonetheless, many of the management questions demanded by the WFD will not be resolved by collecting these datasets alone. Long term trends are unlikely to be determined from these data and even if trends are found they are unlikely to be accurately apportioned to the activities that have caused them. The impacts of where and when an action takes place will not be detected at the catchment scale and the cost effectiveness of any mitigation method is unlikely to be quantifiable. Even in small well instrumented catchments the natural variability in rainfall, antecedent patterns and the variability in farming practices will mask any identifiable catchment scale signal. This does not mean the cost of the data acquisition has been wasted, it just means that the knowledge and expertise gained from these data should be used in new novel ways. It will always be difficult to quantify the actual losses occurring at the farm or field scale, but the positive benefits of any mitigation may still be approximated. The evidence for the rate of nutrient removal from a local sediment trap, wetland and a pond can be shown with high resolution datasets. However, any quantifiable results are still highly localised and the transfer and upscaling of any findings must be done with care. Modelling these datasets is also possible and the nature of models have evolved in the

  15. Monitoring High-Frequency Ocean Signals Using Low-Cost Gnss/imu Buoys

    Science.gov (United States)

    Huang, Yu-Lun; Kuo, Chung-Yen; Shih, Chiao-Hui; Lin, Li-Ching; Chiang, Kai-wei; Cheng, Kai-Chien

    2016-06-01

    In oceans there are different ocean signals covering the multi-frequencies including tsunami, meteotsunami, storm surge, as sea level change, and currents. These signals have the direct and significant impact on the economy and life of human-beings. Therefore, measuring ocean signals accurately becomes more and more important and necessary. Nowadays, there are many techniques and methods commonly used for monitoring oceans, but each has its limitation. For example, tide gauges only measure sea level relative to benchmarks and are disturbed unevenly, and satellite altimeter measurements are not continuous and inaccurate near coastal oceans. In addition, high-frequency ocean signals such as tsunami and meteotsunami cannot be sufficiently detected by 6-minutes tide gauge measurements or 10-day sampled altimetry data. Moreover, traditional accelerometer buoy is heavy, expensive and the low-frequency noise caused by the instrument is unavoidable. In this study, a small, low-cost and self-assembly autonomous Inertial Measurement Unit (IMU) that independently collects continuous acceleration and angular velocity data is mounted on a GNSS buoy to provide the positions and tilts of the moving buoy. The main idea is to integrate the Differential GNSS (DGNSS) or Precise Point Positioning (PPP) solutions with IMU data, and then evaluate the performance by comparing with in situ tide gauges. The validation experiments conducted in the NCKU Tainan Hydraulics Laboratory showed that GNSS and IMU both can detect the simulated regular wave frequency and height, and the field experiments in the Anping Harbor, Tainan, Taiwan showed that the low-cost GNSS buoy has an excellent ability to observe significant wave heights in amplitude and frequency.

  16. High frequency monitoring of pesticides in runoff water from a vineyard: ecotoxicological and hysteresis pattern analysis

    Science.gov (United States)

    Lefrancq, Marie; Jadas-Hécart, Alain; La Jeunesse, Isabelle; Landry, David; Payraudeau, Sylvain

    2017-04-01

    Rainfall-induced peaks in pesticide concentrations can occur rapidly; therefore, low frequency sampling may largely underestimate maximum pesticide concentrations and fluxes. Detailed storm-based sampling of pesticide concentrations in runoff water to better predict pesticide sources, transport pathways and toxicity within the headwater catchments is actually lacking. High frequency monitoring (2 min) of dissolved concentrations and loads for seven pesticides (Dimetomorph, Fluopicolide, Glyphosate, Iprovalicarb, Tebuconazole, Tetraconazole and Triadimenol) and one degradation product (AMPA) were assessed for 20 runoff events from 2009 to 2012 at the outlet of a vineyard catchment in the Layon catchment in France. The pesticide concentrations reached 387 µg/L. All of the runoff events exceeded the mandated acceptable concentrations of 0.1 µg/L for each pesticide (European directive 2013/39/EC). High resolution sampling used to detect the peak pesticide levels revealed that Toxic Units (TU) for algae, invertebrates and fish often exceeded the European Uniform principles (25%). The instantaneous and average (time or discharge-weighted) concentrations indicated an up to 30- or 4-fold underestimation of the TU obtained when measuring the maximum concentrations, respectively, highlighting the important role of the sampling methods for assessing peak exposure. High resolution sampling combined with concentration-discharge hysteresis analyses revealed that clockwise responses were predominant (52%), indicating that Hortonian runoff is the prevailing surface runoff trigger mechanism in the study catchment. The hysteresis patterns for suspended solids and pesticides were highly dynamic and storm- and chemical-dependent. Intense rainfall events induced stronger C-Q hysteresis (magnitude). This study provides new insights into the complexity of pesticide dynamics in runoff water and highlights the ability of hysteresis analysis to improve the understanding of pesticide

  17. MONITORING HIGH-FREQUENCY OCEAN SIGNALS USING LOW-COST GNSS/IMU BUOYS

    Directory of Open Access Journals (Sweden)

    Y.-L. Huang

    2016-06-01

    Full Text Available In oceans there are different ocean signals covering the multi-frequencies including tsunami, meteotsunami, storm surge, as sea level change, and currents. These signals have the direct and significant impact on the economy and life of human-beings. Therefore, measuring ocean signals accurately becomes more and more important and necessary. Nowadays, there are many techniques and methods commonly used for monitoring oceans, but each has its limitation. For example, tide gauges only measure sea level relative to benchmarks and are disturbed unevenly, and satellite altimeter measurements are not continuous and inaccurate near coastal oceans. In addition, high-frequency ocean signals such as tsunami and meteotsunami cannot be sufficiently detected by 6-minutes tide gauge measurements or 10-day sampled altimetry data. Moreover, traditional accelerometer buoy is heavy, expensive and the low-frequency noise caused by the instrument is unavoidable. In this study, a small, low-cost and self-assembly autonomous Inertial Measurement Unit (IMU that independently collects continuous acceleration and angular velocity data is mounted on a GNSS buoy to provide the positions and tilts of the moving buoy. The main idea is to integrate the Differential GNSS (DGNSS or Precise Point Positioning (PPP solutions with IMU data, and then evaluate the performance by comparing with in situ tide gauges. The validation experiments conducted in the NCKU Tainan Hydraulics Laboratory showed that GNSS and IMU both can detect the simulated regular wave frequency and height, and the field experiments in the Anping Harbor, Tainan, Taiwan showed that the low-cost GNSS buoy has an excellent ability to observe significant wave heights in amplitude and frequency.

  18. High-frequency ultrasound for monitoring changes in liver tissue during preservation

    Energy Technology Data Exchange (ETDEWEB)

    Vlad, Roxana M [Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Czarnota, Gregory J [Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Giles, Anoja [Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Sherar, Michael D [Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Hunt, John W [Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Kolios, Michael C [Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada)

    2005-01-21

    Currently the only method to assess liver preservation injury is based on liver appearance and donor medical history. Previous work has shown that high-frequency ultrasound could detect ischemic cell death due to changes in cell morphology. In this study, we use high-frequency ultrasound integrated backscatter to assess liver damage in experimental models of liver ischemia. Ultimately, our goal is to predict organ suitability for transplantation using high-frequency imaging and spectral analysis techniques. To examine the effects of liver ischemia at different temperatures, livers from Wistar rats were surgically excised, immersed in phosphate buffer saline and stored at 4 and 20 deg. C for 24 h. To mimic organ preservation, livers were excised, flushed with University of Wisconsin (UW) solution and stored at 4 deg. C for 24 h. Preservation injury was simulated by either not flushing livers with UW solution or, before scanning, allowing livers to reach room temperature. Ultrasound images and corresponding radiofrequency data were collected over the ischemic period. No significant increase in integrated backscatter ({approx}2.5 dBr) was measured for the livers prepared using standard preservation conditions. For all other ischemia models, the integrated backscatter increased by 4-9 dBr demonstrating kinetics dependent on storage conditions. The results provide a possible framework for using high-frequency imaging to non-invasively assess liver preservation injury.

  19. Monitoring of hidden fatigue crack growth in multi-layer aircraft structures using high frequency guided waves

    Science.gov (United States)

    Chan, H.; Masserey, B.; Fromme, P.

    2015-03-01

    Varying loading conditions of aircraft structures result in stress concentration at fastener holes, where multi-layered components are connected, potentially leading to the development of hidden fatigue cracks in inaccessible layers. High frequency guided waves propagating along the structure allow for the structural health monitoring (SHM) of such components, e.g., aircraft wings. Experimentally the required guided wave modes can be easily excited using standard ultrasonic wedge transducers. However, the sensitivity for the detection of small, potentially hidden, fatigue cracks has to be ascertained. The type of multi-layered model structure investigated consists of two adhesively bonded aluminum plate-strips with a sealant layer. Fatigue experiments were carried out and the growth of fatigue cracks at the fastener hole in one of the metallic layers was monitored optically during cyclic loading. The influence of the fatigue cracks of increasing size on the scattered guided wave field was evaluated. The sensitivity and repeatability of the high frequency guided wave modes to detect and monitor the fatigue crack growth was investigated, using both standard pulse-echo equipment and a laser interferometer. The potential for hidden fatigue crack growth monitoring at critical and difficult to access fastener locations from a stand-off distance was ascertained. The robustness of the methodology for practical in situ ultrasonic monitoring of fatigue crack growth is discussed.

  20. The ISMAR high frequency coastal radar network: Monitoring surface currents for management of marine resources

    DEFF Research Database (Denmark)

    Carlson, Daniel Frazier

    2015-01-01

    The Institute of Marine Sciences (ISMAR) of the National Research Council of Italy (CNR) established a High Frequency (HF) Coastal Radar Network for the measurement of the velocity of surface currents in coastal seas. The network consists of four HF radar systems located on the coast of the Gargano...... of geospatial data, a netCDF architecture has been defined on the basis of the Radiowave Operators Working Group (US ROWG) recommendations and compliant to the Climate and Forecast (CF) Metadata Conventions CF-1.6. The hourly netCDF files are automatically attached to a Thematic Real-time Environmental...... by the ISMAR HF radar network are presently used in a number of applications, ranging from oil spill and SAR to fishery and coastal management applications....

  1. Subsurface photodisruption in pig skin as monitored by high-frequency ultrasound

    Science.gov (United States)

    Tse, Christine; Zohdy, Marwa J.; Ye, Jing Yong; O'Donnell, Matthew

    2006-02-01

    For diagnostic or therapeutic technologies using femtosecond laser-induced optical breakdown (LIOB) in turbid biological tissues, pulses of sufficient fluence must be delivered to the site of interest. As light attenuates and diffuses rapidly due to wavelength-dependent absorption and scattering, it is important to develop penetration optimization schemes. In this study, we use a high frequency (50MHz) ultrasonic technique to investigate the precision and penetration depth limitations of infrared femtosecond laser-induced photodisruption in excised pig skin. Optical parameters varied include laser fluence (energy density in J/cm2) and focusing numerical aperture. Our ultrasonic method uses sensitive detection of laser-induced bubbles to measure breakdown extent. Using a geometrically focused Nd:Glass laser (1053 nm, 800 fs) source, we show that acoustically detectable bubbles can be produced as deep as 900 um into excised porcine skin. As penetration exceeds several hundred microns, however, multiple bubbles stacked at different depths can be produced with a single laser excitation. Secondary bubble creation is more likely at supra-threshold fluences or with low NA ( 0.4) for deeper focusing, aberrations can severely distort the beam, increasing the perceived LIOB-threshold with maximal penetrations of less than 500um. Using an index matching fluid (i.e. aqueous glycerol solutions) to help reduce scattering, we are able to improve penetration. However, multiple breakdown sites and the corresponding reduction in precision is still likely in skin even with glycerol treatment.

  2. Feasibility study of monitoring of plasma etching chamber conditions using superimposed high-frequency signals on rf power transmission line.

    Science.gov (United States)

    Kasashima, Y; Uesugi, F

    2015-10-01

    An in situ monitoring system that can detect changes in the conditions of a plasma etching chamber has been developed. In the system, low-intensity high-frequency signals are superimposed on the rf power transmission line used for generating plasma. The system measures reflected high-frequency signals and detects the change in their frequency characteristics. The results indicate that the system detects the changes in the conditions in etching chambers caused by the changes in the electrode gap and the inner wall condition and demonstrate the effectiveness of the system. The system can easily be retrofitted to mass-production equipment and it can be used with or without plasma discharge. Therefore, our system is suitable for in situ monitoring of mass-production plasma etching chambers. The system is expected to contribute to development of predictive maintenance, which monitors films deposited on the inner wall of the chamber and prevents equipment faults caused by misalignment of chamber parts in mass-production equipment.

  3. High-frequency remote monitoring of large lakes with MODIS 500 m imagery

    Science.gov (United States)

    McCullough, Ian M.; Loftin, Cynthia S.; Sader, Steven A.

    2012-01-01

    Satellite-based remote monitoring programs of regional lake water quality largely have relied on Landsat Thematic Mapper (TM) owing to its long image archive, moderate spatial resolution (30 m), and wide sensitivity in the visible portion of the electromagnetic spectrum, despite some notable limitations such as temporal resolution (i.e., 16 days), data pre-processing requirements to improve data quality, and aging satellites. Moderate-Resolution Imaging Spectroradiometer (MODIS) sensors on Aqua/Terra platforms compensate for these shortcomings, although at the expense of spatial resolution. We developed and evaluated a remote monitoring protocol for water clarity of large lakes using MODIS 500 m data and compared MODIS utility to Landsat-based methods. MODIS images captured during May–September 2001, 2004 and 2010 were analyzed with linear regression to identify the relationship between lake water clarity and satellite-measured surface reflectance. Correlations were strong (R² = 0.72–0.94) throughout the study period; however, they were the most consistent in August, reflecting seasonally unstable lake conditions and inter-annual differences in algal productivity during the other months. The utility of MODIS data in remote water quality estimation lies in intra-annual monitoring of lake water clarity in inaccessible, large lakes, whereas Landsat is more appropriate for inter-annual, regional trend analyses of lakes ≥ 8 ha. Model accuracy is improved when ancillary variables are included to reflect seasonal lake dynamics and weather patterns that influence lake clarity. The identification of landscape-scale drivers of regional water quality is a useful way to supplement satellite-based remote monitoring programs relying on spectral data alone.

  4. The Water Quality of the River Enborne, UK: Observations from High-Frequency Monitoring in a Rural, Lowland River System

    Directory of Open Access Journals (Sweden)

    Sarah J. Halliday

    2014-01-01

    Full Text Available This paper reports the results of a 2-year study of water quality in the River Enborne, a rural river in lowland England. Concentrations of nitrogen and phosphorus species and other chemical determinands were monitored both at high-frequency (hourly, using automated in situ instrumentation, and by manual weekly sampling and laboratory analysis. The catchment land use is largely agricultural, with a population density of 123 persons km−2. The river water is largely derived from calcareous groundwater, and there are high nitrogen and phosphorus concentrations. Agricultural fertiliser is the dominant source of annual loads of both nitrogen and phosphorus. However, the data show that sewage effluent discharges have a disproportionate effect on the river nitrogen and phosphorus dynamics. At least 38% of the catchment population use septic tank systems, but the effects are hard to quantify as only 6% are officially registered, and the characteristics of the others are unknown. Only 4% of the phosphorus input and 9% of the nitrogen input is exported from the catchment by the river, highlighting the importance of catchment process understanding in predicting nutrient concentrations. High-frequency monitoring will be a key to developing this vital process understanding.

  5. High frequency seismic monitoring of debris flows at Chalk Cliffs (CO), USA

    Science.gov (United States)

    Coviello, Velio; Kean, Jason; Smith, Joel; Coe, Jeffrey; Arattano, Massimo; McCoy, Scott

    2015-04-01

    A growing number of studies adopt passive seismic monitoring techniques to investigate slope instabilities and landslide processes. These techniques are attractive and convenient because large areas can be monitored from a safe distance. This is particularly true when the phenomena under investigation are rapid and infrequent mass movements like debris flows. Different types of devices are used to monitor debris flow processes, but among them ground vibration detectors (GVDs) present several, specific advantages that encourage their use. These advantages include: (i) the possibility to be installed outside the channel bed, (ii) the high adaptability to different and harsh field conditions, and (iii) the capability to detect the debris flow front arrival tens of seconds earlier than contact and stage sensors. Ground vibration data can provide relevant information on the dynamics of debris flows such as timing and velocity of the main surges. However, the processing of the raw seismic signal is usually needed, both to obtain a more effective representation of waveforms and to decrease the amount of data that need to be recorded and analyzed. With this objective, the methods of Amplitude and Impulses are commonly adopted to transform the raw signal to a 1-Hz signal that allows for a more useful representation of the phenomenon. In that way, peaks and other features become more visible and comparable with data obtained from other monitoring devices. In this work, we present the first debris flows seismic recordings gathered in the Chalk Cliffs instrumented basin, central Colorado, USA. In May 2014, two 4.5-Hz, three-axial geophones were installed in the upper part of the catchment. Seismic data are sampled at 333 Hz and then recorded by a standalone recording unit. One geophone is directly installed on bedrock, the other one mounted on a 1-m boulder partially buried in colluvium. This latter sensor integrates a heavily instrumented cross-section consisting of a 225 cm2

  6. Applications of optical sensors for high-frequency water-quality monitoring and research

    Science.gov (United States)

    Pellerin, Brian

    2015-01-01

    The recent commercial availability of in-situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents over time scales during which environmental conditions actually change. Traditional approaches for data collection (daily to monthly discrete samples) are often limited by high sample collection, processing, and analytical costs, difficult site access, and logistical challenges, particularly for long-term sampling at a large number of sites. Optical sensors that continuously measure constituents in the environment by absorbance or fluorescence properties (Figure 1) have had a long history of use in oceanography for measuring highly resolved concentrations and fluxes of organic matter, nutrients, and algal material. However, much of the work using commercially-available optical sensors in rivers and streams has taken place in only the last few years. Figure 1. [NOT SHOWN] Optical sensor technology is now sufficiently developed to warrant broader application for research and monitoring in coastal and freshwater systems, and the United States Geological Survey (a U.S. science agency) is now using these sensors in a variety of research and monitoring programs to better understand water quality in-situ and in real-time. Examples are numerous and range from the applications of nitrate sensors for calculating loads to estuaries susceptible to hypoxia (Pellerin et al., 2014) to the use of fluorometers to estimate methymercury fluxes (Bergamaschi et al., 2011) and disinfection byproduct formation (Carpenter et al., 2013). Transmitting these data in real-time provides information that can be used for early trend detection, help identify monitoring gaps critical for water management, and provide science-based decision support across a range of issues related to water quality, freshwater ecosystems, and human health. Despite the value of these sensors, collecting data that

  7. Simulating high frequency water quality monitoring data using a catchment runoff attenuation flux tool (CRAFT).

    Science.gov (United States)

    Adams, Russell; Quinn, Paul F; Perks, Matthew; Barber, Nicholas J; Jonczyk, Jennine; Owen, Gareth J

    2016-12-01

    High resolution water quality data has recently become widely available from numerous catchment based monitoring schemes. However, the models that can reproduce time series of concentrations or fluxes have not kept pace with the advances in monitoring data. Model performance at predicting phosphorus (P) and sediment concentrations has frequently been poor with models not fit for purpose except for predicting annual losses. Here, the data from the Eden Demonstration Test Catchments (DTC) project have been used to calibrate the Catchment Runoff Attenuation Flux Tool (CRAFT), a new, parsimonious model developed with the aim of modelling both the generation and attenuation of nutrients and sediments in small to medium sized catchments. The CRAFT has the ability to run on an hourly timestep and can calculate the mass of sediments and nutrients transported by three flow pathways representing rapid surface runoff, fast subsurface drainage and slow groundwater flow (baseflow). The attenuation feature of the model is introduced here; this enables surface runoff and contaminants transported via this pathway to be delayed in reaching the catchment outlet. It was used to investigate some hypotheses of nutrient and sediment transport in the Newby Beck Catchment (NBC) Model performance was assessed using a suite of metrics including visual best fit and the Nash-Sutcliffe efficiency. It was found that this approach for water quality models may be the best assessment method as opposed to using a single metric. Furthermore, it was found that, when the aim of the simulations was to reproduce the time series of total P (TP) or total reactive P (TRP) to get the best visual fit, that attenuation was required. The model will be used in the future to explore the impacts on water quality of different mitigation options in the catchment; these will include attenuation of surface runoff. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. A Multiband-Instability-Monitor for High-Frequency Intra-Bunch Beam Diagnostics

    CERN Document Server

    Steinhagen, R J; Lucas, T G

    2013-01-01

    The maximum beam particle intensity and minimum emittance that can be injected, accelerated and stored in high-brightness lepton as well as high-energy hadron accelerators is fundamentally limited by self-amplifying beam instabilities, intrinsic to unavoidable imperfections in accelerators. Traditionally, intra-bunch or head-tail particle motion has been measured using fast digitizers, with even using state-of-the-art technology being limited in their effective intra-bunch position resolution to few tens of um in the multi-GHz regime. To improve on the present signal processing, a multiband-instability-monitor (MIM) prototype system has been designed, constructed and tested at the CERN Super- Proton-Synchrotron (SPS) and Large Hadron Collider (LHC). The system splits the signal into multiple equallyspaced narrowfrequency bands that are processed and analysed in parallel. Working with narrow-band signals permits the use of much higher resolution analogue-to-digitalconverters that can be used to resolve nm-scal...

  9. The information content of high-frequency environmental monitoring data signals pollution events in the coastal ocean.

    Science.gov (United States)

    Jeong, Youngsul; Sanders, Brett F; Grant, Stanley B

    2006-10-15

    There are an increasing number of coastal ocean observing systems that deploy new technology for environmental sensing and stream these data in near-real-time to end-users (e.g., scientists and coastal managers) via the worldwide web. The temporal resolution, spatial coverage, and accessibility of these data open up new opportunities for better understanding and managing the coastal ocean, but they also present enormous challenges relative to data processing and data interpretation, particularly in cases where these data are to inform rapid management decision making. Here we demonstrate that changes in surf zone water quality at a popular beach in southern California are signaled by changes in the Fisher Information and Shannon Entropy of high frequency (1/4 min(-1)) measurements of salinity and temperature in the surf zone. These results support the hypothesis that the information content of environmental signals, such as salinity and temperature, can be used to identify changes in the water quality of the coastal ocean. More generally, the approach described here-of using information theory indices calculated from monitoring data as real-time indicators of environmental change-is quite general, and may therefore be applicable to other situations where rapid management decisions are based on high-frequency measurements of environmental parameters.

  10. Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

    Science.gov (United States)

    Li, Y.; Cutright, S.; Dyke, R.; Templeton, J.; Gasbarre, J.; Novak, F.

    2015-01-01

    The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination

  11. High frequency non-invasive (HFNI bio-sensors as a potential tool for marine monitoring and assessments

    Directory of Open Access Journals (Sweden)

    Hector Andrade

    2016-10-01

    Full Text Available Marine ecosystems all over the globe are facing multiple simultaneous stressors including rapid climatic change and increased resource exploitation, such as fishing, petroleum exploration and shipping. The EU-funded DEVOTES project (DEVelopment Of innovative Tools for understanding marine biodiversity and assessing good Environmental Status aims to better understand the relationships between pressures from human activities and climatic influences and their effects on marine ecosystems. To achieve these goals, it is necessary among others, to test and validate innovative monitoring tools to improve our understanding of ecosystem and biodiversity changes. This paper outlines the application of a high frequency non-invasive (HFNI valvometer as a potential tool for long-term marine monitoring and assessments. The principle of the method is based on the regular gaping behaviour (closing and opening of the valves of bivalve molluscs and the fact that physical or chemical stressors disrupt that gaping reference pattern. Bivalve gaping behaviour is monitored in the natural environment, remotely, continuously over a time period of years, requirements that must be fulfilled if bivalve behaviour is to be a useful biomonitoring tool. Here, we review the literature and highlight potential uses of the HFNI valvometry as a biosensor, to monitor and provide early-warning alerts of changes in water quality, such as global temperature increase, releases of contaminants and toxic algal blooms. Finally, potential relevant applications for monitoring and assessing environmental status of marine waters in the context of the Marine Strategy Framework Directive are identified. Relevant descriptors, Criteria and Indicators of Good Environmental Status that might be monitored using the HFNI valvometer are discussed for monitoring bathing beaches and harbours, petroleum installations and aquaculture sites.

  12. Designing a high-frequency nutrient and biogeochemical monitoring network for the Sacramento–San Joaquin Delta, northern California

    Science.gov (United States)

    Bergamaschi, Brian A.; Downing, Bryan D.; Kraus, Tamara E.C.; Pellerin, Brian A.

    2017-07-11

    Executive SummaryThis report is the third in a series of three reports that provide information about how high-frequency (HF) nutrient monitoring may be used to assess nutrient inputs and dynamics in the Sacramento–San Joaquin Delta, California (Delta). The purpose of this report is to provide the background, principles, and considerations for designing an HF nutrient-monitoring network for the Delta to address high-priority, nutrient-management questions. The report starts with discussion of the high-priority management questions to be addressed, continues through discussion of the questions and considerations that place demands and constraints on network design, discusses the principles applicable to network design, and concludes with the presentation of three example nutrient-monitoring network designs for the Delta. For three example network designs, we assess how they would address high-priority questions that have been identified by the Delta Regional Monitoring Program (Delta Regional Monitoring Program Technical Advisory Committee, 2015).This report, along with the other two reports of this series (Kraus and others, 2017; Downing and others, 2017), was drafted in cooperation with the Delta Regional Monitoring Program to help scientists, managers, and planners understand how HF data improve our understanding of nutrient sources and sinks, drivers, and effects in the Delta. The first report in the series (Kraus and others, 2017) provides an introduction to the reasons for and fundamental concepts behind using HF monitoring measurements, including a brief summary of nutrient status and trends in the Delta and an extensive literature review showing how and where other research and monitoring programs have used HF monitoring to improve our understanding of nutrient cycling. The report covers the various technologies available for HF nutrient monitoring and presents the different ways HF monitoring instrumentation may be used for both fixed station and spatial

  13. Long-term, high-frequency water quality monitoring in an agricultural catchment: insights from spectral analysis

    Science.gov (United States)

    Aubert, Alice; Kirchner, James; Faucheux, Mikael; Merot, Philippe; Gascuel-Odoux, Chantal

    2013-04-01

    measurements. At higher frequencies, however, the spectra steepen to a slope of -2, indicating that at sub-daily time scales the concentration time series become relatively smooth. However, at time scales shorter than 2-3 hours, the spectra flatten to a slope near zero (white noise), reflecting analytical noise in the measurement probe. This result demonstrates that measuring water quality dynamics at high frequencies also requires high measurement precision, because as measurements are taken closer and closer together in time, the real-world differences that must be measured between adjacent measurements become smaller and smaller. Our results highlight the importance of quantifying the spectral properties of analytical noise in environmental measurements, to identify frequency ranges where measurements could be dominated by analytical noise instead of real-world signals. 1. Kirchner, J.W., Feng, X., Neal, C., Robson, A.J., 2004. The fine structure of water-quality dynamics: the (high-frequency) wave of the future. Hydrological Processes, 18(7): 1353-1359 2. Aubert, A.H. et al., 2012. The chemical signature of a livestock farming catchment: synthesis from a high-frequency multi-element long term monitoring. HESSD, 9(8): 9715 - 9741 3. Kirchner, J.W. and Neal, C., 2013. Universal fractal scaling in water quality dynamics across the periodic table. Manuscript in review.

  14. An introduction to high-frequency nutrient and biogeochemical monitoring for the Sacramento–San Joaquin Delta, northern California

    Science.gov (United States)

    Kraus, Tamara E.C.; Bergamaschi, Brian A.; Downing, Bryan D.

    2017-07-11

    Executive SummaryThis report is the first in a series of three reports that provide information about high-frequency (HF) nutrient and biogeochemical monitoring in the Sacramento–San Joaquin Delta of northern California (Delta). This first report provides an introduction to the reasons for and fundamental concepts behind collecting HF measurements, and describes the benefits associated with a real-time, continuous, HF, multi-parameter water quality monitoring station network that is co-located with flow stations. It then provides examples of how HF nutrient measurements have improved our understating of nutrient sources and cycling in aquatic systems worldwide, followed by specific examples from the Delta. These examples describe the ways in which HF instrumentation may be used for both fixed-station and spatial assessments. The overall intent of this document is to describe how HF measurements currently (2017) are being used in the Delta to examine the relationship between nutrient concentrations, nutrient cycling, and aquatic habitat conditions.The second report in the series (Downing and others, 2017) summarizes information about HF nutrient and associated biogeochemical monitoring in the northern Delta. The report synthesizes data available from the nutrient and water quality monitoring network currently operated by the U.S. Geological Survey in this ecologically important region of the Delta. In the report, we present and discuss the available data at various timescales—first, at the monthly, seasonal, and inter-annual timescales; and, second, for comparison, at the tidal and event (for example, storms, reservoir releases, phytoplankton blooms) timescales. As expected, we determined that there is substantial variability in nitrate concentrations at short timescales within hours, but also significant variability at longer timescales such as months or years. This multi-scale, high variability affects calculation of fluxes and loads, indicating that HF

  15. Geochemical responses of forested catchments to bark beetle infestation: Evidence from high frequency in-stream electrical conductivity monitoring

    Science.gov (United States)

    Su, Ye; Langhammer, Jakub; Jarsjö, Jerker

    2017-07-01

    Under the present conditions of climate warming, there has been an increased frequency of bark beetle-induced tree mortality in Asia, Europe, and North America. This study analyzed seven years of high frequency monitoring of in-stream electrical conductivity (EC), hydro-climatic conditions, and vegetation dynamics in four experimental catchments located in headwaters of the Sumava Mountains, Central Europe. The aim was to determine the effects of insect-induced forest disturbance on in-stream EC at multiple timescales, including annual and seasonal average conditions, daily variability, and responses to individual rainfall events. Results showed increased annual average in-stream EC values in the bark beetle-infected catchments, with particularly elevated EC values during baseflow conditions. This is likely caused by the cumulative loading of soil water and groundwater that discharge excess amounts of substances such as nitrogen and carbon, which are released via the decomposition of the needles, branches, and trunks of dead trees, into streams. Furthermore, we concluded that infestation-induced changes in event-scale dynamics may be largely responsible for the observed shifts in annual average conditions. For example, systematic EC differences between baseflow conditions and event flow conditions in relatively undisturbed catchments were essentially eliminated in catchments that were highly disturbed by bark beetles. These changes developed relatively rapidly after infestation and have long-lasting (decadal-scale) effects, implying that cumulative impacts of increasingly frequent bark beetle outbreaks may contribute to alterations of the hydrogeochemical conditions in more vulnerable mountain regions.

  16. Turmoil at Turrialba Volcano (Costa Rica): Degassing and eruptive processes inferred from high-frequency gas monitoring.

    Science.gov (United States)

    de Moor, J Maarten; Aiuppa, A; Avard, G; Wehrmann, H; Dunbar, N; Muller, C; Tamburello, G; Giudice, G; Liuzzo, M; Moretti, R; Conde, V; Galle, B

    2016-08-01

    Eruptive activity at Turrialba Volcano (Costa Rica) has escalated significantly since 2014, causing airport and school closures in the capital city of San José. Whether or not new magma is involved in the current unrest seems probable but remains a matter of debate as ash deposits are dominated by hydrothermal material. Here we use high-frequency gas monitoring to track the behavior of the volcano between 2014 and 2015 and to decipher magmatic versus hydrothermal contributions to the eruptions. Pulses of deeply derived CO2-rich gas (CO2/Stotal > 4.5) precede explosive activity, providing a clear precursor to eruptive periods that occurs up to 2 weeks before eruptions, which are accompanied by shallowly derived sulfur-rich magmatic gas emissions. Degassing modeling suggests that the deep magmatic reservoir is ~8-10 km deep, whereas the shallow magmatic gas source is at ~3-5 km. Two cycles of degassing and eruption are observed, each attributed to pulses of magma ascending through the deep reservoir to shallow crustal levels. The magmatic degassing signals were overprinted by a fluid contribution from the shallow hydrothermal system, modifying the gas compositions, contributing volatiles to the emissions, and reflecting complex processes of scrubbing, displacement, and volatilization. H2S/SO2 varies over 2 orders of magnitude through the monitoring period and demonstrates that the first eruptive episode involved hydrothermal gases, whereas the second did not. Massive degassing (>3000 T/d SO2 and H2S/SO2 > 1) followed, suggesting boiling off of the hydrothermal system. The gas emissions show a remarkable shift to purely magmatic composition (H2S/SO2 < 0.05) during the second eruptive period, reflecting the depletion of the hydrothermal system or the establishment of high-temperature conduits bypassing remnant hydrothermal reservoirs, and the transition from phreatic to phreatomagmatic eruptive activity.

  17. Real time high frequency monitoring of water quality in river streams using a UV-visible spectrometer: interest, limits and consequences for monitoring strategies

    Science.gov (United States)

    Faucheux, Mikaël; Fovet, Ophélie; Gruau, Gérard; Jaffrézic, Anne; Petitjean, Patrice; Gascuel-Odoux, Chantal; Ruiz, Laurent

    2013-04-01

    Stream water chemistry is highly variable in space and time, therefore high frequency water quality measurement methods are likely to lead to conceptual advances in the hydrological sciences. Sub-daily data on water quality improve the characterization of pollutant sources and pathways during flood events as well as during long-term periods [1]. However, real time, high frequency monitoring devices needs to be properly calibrated and validated in real streams. This study analyses data from in situ monitoring of a stream water quality. During two hydrological years (2010-11, 2011-12), a submersible UV-visible spectrometer (Scan Spectrolyser) was used for surface water quality measurement at the outlet of a headwater catchment located at Kervidy-Naizin, Western France (AgrHys long-term hydrological observatory, http://www.inra.fr/ore_agrhys/). The spectrometer is reagentless and equipped with an auto-cleaning system. It allows real time, in situ and high frequency (20 min) measurements and uses a multiwavelengt spectral (200-750 nm) for simultaneous measurement of nitrate, dissolved organic carbon (DOC) and total suspended solids (TSS). A global calibration based on a PLS (Partial Least Squares) regression is provided by the manufacturer as default configuration of the UV-visible spectrometer. We carried out a local calibration of the spectrometer based on nitrates and DOC concentrations analysed in the laboratory from daily manual sampling and sub-daily automatic sampling of flood events. TSS results are compared with 15 min turbidity records from a continuous turdidimeter (Ponsel). The results show a good correlation between laboratory data and spectrometer data both during basis flows periods and flood events. However, the local calibration gives better results than the global one. Nutrient fluxes estimates based on high and different low frequency time series (daily to monthly) are compared to discuss the implication for environmental monitoring strategies. Such

  18. The chemical signature of a livestock farming catchment: synthesis from a high-frequency multi-element long term monitoring

    Directory of Open Access Journals (Sweden)

    A. H. Aubert

    2012-08-01

    Full Text Available Assessing the impact of human pressures on water quality is difficult. First, there is a high temporal and spatial variability of climate and human activity. Second, chemical elements have their own characteristics mixing short and long term dynamics. High frequency, long-term and multi-element measurements are required. But, such data series are scarce. This paper aims at determining what the hydro-chemical particularities of a livestock farming catchment are in a temperate climatic context.

    It is based on an original and never published time series, from Kervidy-Naizin headwater catchment. Stream chemistry was monitored daily and shallow groundwater roughly every four month, for 10 yr and five elements (nitrate, sulphate, chloride, and dissolved organic and inorganic carbon.

    The five elements present strong but different seasonal patterns. Nitrate and chloride present a seasonal flush, all along or at the beginning of the wet season, respectively. Sulphate, organic and inorganic carbon present storm flushes, with constant or decreasing peaks throughout the wet season. These depicted nitrate and chloride patterns are typical of a livestock farming catchment. There, nitrate and chloride coming from organic fertilisation have been accumulating over years in the shallow groundwater. They are seasonally flushed when the groundwater connects to the stream. Sulphate, organic and inorganic carbon patterns do not seem specific to agricultural catchments. These elements are produced each year and flushed by storms. Finally, a generic classification of temporal patterns and elements is established for agricultural catchments. It is based on the distance of the source component to the stream and the dominant controlling process (accumulation versus production. This classification could be applied to any chemical element and help assessing the level of water disturbances.

  19. Use of High-Frequency In-Home Monitoring Data May Reduce Sample Sizes Needed in Clinical Trials.

    Directory of Open Access Journals (Sweden)

    Hiroko H Dodge

    walking speed collected at baseline, 262 subjects are required. Similarly for computer use, 26 subjects are required.Individual-specific thresholds of low functional performance based on high-frequency in-home monitoring data distinguish trajectories of MCI from NC and could substantially reduce sample sizes needed in dementia prevention RCTs.

  20. High-frequency monitoring reveals nutrient sources and transport processes in an agriculture-dominated lowland water system

    Science.gov (United States)

    van der Grift, Bas; Broers, Hans Peter; Berendrecht, Wilbert; Rozemeijer, Joachim; Osté, Leonard; Griffioen, Jasper

    2016-05-01

    Many agriculture-dominated lowland water systems worldwide suffer from eutrophication caused by high nutrient loads. Insight in the hydrochemical functioning of embanked polder catchments is highly relevant for improving the water quality in such areas or for reducing export loads to downstream water bodies. This paper introduces new insights in nutrient sources and transport processes in a polder in the Netherlands situated below sea level using high-frequency monitoring technology at the outlet, where the water is pumped into a higher situated lake, combined with a low-frequency water quality monitoring programme at six locations within the drainage area. Seasonal trends and short-scale temporal dynamics in concentrations indicated that the NO3 concentration at the pumping station originated from N loss from agricultural lands. The NO3 loads appear as losses via tube drains after intensive rainfall events during the winter months due to preferential flow through the cracked clay soil. Transfer function-noise modelling of hourly NO3 concentrations reveals that a large part of the dynamics in NO3 concentrations during the winter months can be related to rainfall. The total phosphorus (TP) concentration and turbidity almost doubled during operation of the pumping station, which points to resuspension of particulate P from channel bed sediments induced by changes in water flow due to pumping. Rainfall events that caused peaks in NO3 concentrations did not results in TP concentration peaks. The rainfall induced and NO3 enriched quick interflow, may also be enriched in TP but retention of TP due to sedimentation of particulate P then results in the absence of rainfall induced TP concentration peaks. Increased TP concentrations associated with run-off events is only observed during a rainfall event at the end of a freeze-thaw cycle. All these observations suggest that the P retention potential of polder water systems is primarily due to the artificial pumping regime

  1. High frequency electromagnetic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Daily, W.; Ramirez, A.; Ueng, T.; Latorre, R.

    1989-09-01

    An experiment was conducted in G Tunnel at the Nevada Test Site to evaluate high frequency electromagnetic tomography as a candidate for in situ monitoring of hydrology in the near field of a heater placed in densely welded tuff. Tomographs of 200 MHz electromagnetic permittivity were made for several planes between boreholes. Data were taken before the heater was turned on, during heating and during cooldown of the rockmass. This data is interpreted to yield maps of changes in water content of the rockmass as a function of time. This interpretation is based on laboratory measurement of electromagnetic permittivity as a function of water content for densely welded tuff. 8 refs., 6 figs.

  2. Evaluating Dense 3d Reconstruction Software Packages for Oblique Monitoring of Crop Canopy Surface

    Science.gov (United States)

    Brocks, S.; Bareth, G.

    2016-06-01

    Crop Surface Models (CSMs) are 2.5D raster surfaces representing absolute plant canopy height. Using multiple CMSs generated from data acquired at multiple time steps, a crop surface monitoring is enabled. This makes it possible to monitor crop growth over time and can be used for monitoring in-field crop growth variability which is useful in the context of high-throughput phenotyping. This study aims to evaluate several software packages for dense 3D reconstruction from multiple overlapping RGB images on field and plot-scale. A summer barley field experiment located at the Campus Klein-Altendorf of University of Bonn was observed by acquiring stereo images from an oblique angle using consumer-grade smart cameras. Two such cameras were mounted at an elevation of 10 m and acquired images for a period of two months during the growing period of 2014. The field experiment consisted of nine barley cultivars that were cultivated in multiple repetitions and nitrogen treatments. Manual plant height measurements were carried out at four dates during the observation period. The software packages Agisoft PhotoScan, VisualSfM with CMVS/PMVS2 and SURE are investigated. The point clouds are georeferenced through a set of ground control points. Where adequate results are reached, a statistical analysis is performed.

  3. Temporal Variability and Annual Fluxes of Water, Sediment and Particulate Phosphorus from a Headwater River in the Tropical Andes: Results from a High-frequency Monitoring Program

    Science.gov (United States)

    Wemple, B. C.; Schloegel, C.

    2015-12-01

    The Mazar River Project, a high-frequency hydrological monitoring program, aims to generate ecohydrological information to inform watershed management in high-mountain areas of southern Ecuador. Rapid development of hydropower, accompanied by new and improved road networks, has resulted in swift changes in land-use and land cover in Ecuador's tropical Andes, all of which underscore the need for detailed information on flow and sediment production from these river systems. National and regional payment for the protection of ecosystem services (PES) programs seek to target critical areas, such as these, for watershed conservation, but are often informed by minimal information on sustainable flows and impacts of land use activities. As part of a program to inform conservation and sustainable water management in the region, we established a hydrological monitoring station in southern Ecuador on the Mazar River, a tributary of the Paute River Basin, situated on the eastern Andean cordillera. The station is equipped with sensors to continuously monitor stream stage and turbidity and an automated sampler for event-based collection of stream water samples, providing high frequency data that reduces the uncertainty of observations. Here, we report observations of continuous runoff and turbidity over the first year of observation, present relationships between turbidity and concentrations of total suspended solids (TSS) and total particulate phosphorus (TP), and provide estimates of annual loads of TSS and TP. Runoff was highly variable over the monitoring period with flows ranging from less than 3 m3/s during baseflow to nearly 80 m3/s during the flood of record. During measured storm events, TSS exceeded 1000 mg/l with maximum measured concentrations exceeding 13 g/l during storm peaks. Turbidity was highly correlated with TSS, which was in turn highly correlated with TP, providing a robust data set for load estimation. We compare our results to other montane rivers in the

  4. Decomposition of Near-Infrared Spectroscopy Signals Using Oblique Subspace Projections: Applications in Brain Hemodynamic Monitoring

    Science.gov (United States)

    Caicedo, Alexander; Varon, Carolina; Hunyadi, Borbala; Papademetriou, Maria; Tachtsidis, Ilias; Van Huffel, Sabine

    2016-01-01

    Clinical data is comprised by a large number of synchronously collected biomedical signals that are measured at different locations. Deciphering the interrelationships of these signals can yield important information about their dependence providing some useful clinical diagnostic data. For instance, by computing the coupling between Near-Infrared Spectroscopy signals (NIRS) and systemic variables the status of the hemodynamic regulation mechanisms can be assessed. In this paper we introduce an algorithm for the decomposition of NIRS signals into additive components. The algorithm, SIgnal DEcomposition base on Obliques Subspace Projections (SIDE-ObSP), assumes that the measured NIRS signal is a linear combination of the systemic measurements, following the linear regression model y = Ax + ϵ. SIDE-ObSP decomposes the output such that, each component in the decomposition represents the sole linear influence of one corresponding regressor variable. This decomposition scheme aims at providing a better understanding of the relation between NIRS and systemic variables, and to provide a framework for the clinical interpretation of regression algorithms, thereby, facilitating their introduction into clinical practice. SIDE-ObSP combines oblique subspace projections (ObSP) with the structure of a mean average system in order to define adequate signal subspaces. To guarantee smoothness in the estimated regression parameters, as observed in normal physiological processes, we impose a Tikhonov regularization using a matrix differential operator. We evaluate the performance of SIDE-ObSP by using a synthetic dataset, and present two case studies in the field of cerebral hemodynamics monitoring using NIRS. In addition, we compare the performance of this method with other system identification techniques. In the first case study data from 20 neonates during the first 3 days of life was used, here SIDE-ObSP decoupled the influence of changes in arterial oxygen saturation from the

  5. Biogeochemical processing of nutrients in groundwater-fed stream during baseflow conditions - the value of fluorescence spectroscopy and automated high-frequency nutrient monitoring

    Science.gov (United States)

    Bieroza, Magdalena; Heathwaite, Louise

    2014-05-01

    Recent research in groundwater-dominated streams indicates that organic matter plays an important role in nutrient transformations at the surface-groundwater interface known as the hyporheic zone. Mixing of water and nutrient fluxes in the hyporheic zone controls in-stream nutrients availability, dynamics and export to downstream reaches. In particular, benthic sediments can form adsorptive sinks for organic matter and reactive nutrients (nitrogen and phosphorus) that sustain a variety of hyporheic processes e.g. denitrification, microbial uptake. Thus, hyporheic metabolism can have an important effect on both quantity (concentration) and quality (labile vs. refractory character) of organic matter. Here high-frequency nutrient monitoring combined with spectroscopic analysis was used to provide insights into biogeochemical processing of a small, agricultural stream in the NE England subject to diffuse nutrient pollution. Biogeochemical data were collected hourly for a week at baseflow conditions when in-stream-hyporheic nutrient dynamics have the greatest impact on stream health. In-stream nutrients (total phosphorus, reactive phosphorus, nitrate nitrogen) and water quality parameters (turbidity, specific conductivity, pH, temperature, dissolved oxygen, redox potential) were measured in situ hourly by an automated bank-side laboratory. Concurrent hourly autosamples were retrieved daily and analysed for nutrients and fine sediments including spectroscopic analyses of dissolved organic matter - excitation-emission matrix (EEM) fluorescence spectroscopy and ultraviolet-visible (UV-Vis) absorbance spectroscopy. Our results show that organic matter can potentially be utilised as a natural, environmental tracer of the biogeochemical processes occurring at the surface-groundwater interface in streams. High-frequency spectroscopic characterisation of in-stream organic matter can provide useful quantitative and qualitative information on fluxes of reactive nutrients in

  6. Microwave Radiometer - high frequency

    Data.gov (United States)

    Oak Ridge National Laboratory — The Microwave Radiometer-High Frequency (MWRHF) provides time-series measurements of brightness temperatures from two channels centered at 90 and 150 GHz. These two...

  7. Synthesis of data from high-frequency nutrient and associated biogeochemical monitoring for the Sacramento–San Joaquin Delta, northern California

    Science.gov (United States)

    Downing, Bryan D.; Bergamaschi, Brian A.; Kraus, Tamara E.C.

    2017-07-11

    Executive SummaryThis report is the second in a series of three reports that provide information about high-frequency (HF) nutrient and biogeochemical monitoring in the Sacramento–San Joaquin Delta of northern California (Delta). The purpose of this report is to synthesize the data available from a nutrient and water-quality HF (about every 15 minutes) monitoring network operated by the U.S. Geological Survey in the northern Delta. In this report, we describe the network and focus on the purpose of each station. We then present and discuss the available data, at various timescales—first at the monthly, seasonal, and inter-annual timescales, and second, for comparison, at the tidal and event timescales. As expected, we determined that there is substantial variability in nitrate-N concentrations at short timescales within hours, but also significant variability at longer timescales such as months or years. Resolving this variability is made possible by the HF data, with the largest variability caused by storms, tides, and diel biological processes. Given this large temporal variability, calculations of cumulative nutrient fluxes (for example, daily, monthly, or annual loads) is difficult without HF data. For example, in the Cache Slough, calculation of the annual load without the tidal variability resulted in a 30 percent underestimation of the true annual load value. We conclude that HF measurements are important for accurate determination of fluxes and loads in tidal environments, but, more importantly, provide important insights into processes and rates of nutrient cycling.This report, along with the other two reports of this series (Bergamaschi and others, 2017; Kraus, Bergamaschi, and others, 2017), was drafted in cooperation with the Delta Regional Monitoring Program to help scientists, managers, and planners understand how HF data improve our understanding of nutrient sources and sinks, drivers, and effects in the Delta. The first report in the series

  8. Comparison of the effectiveness of monitoring Cisplatin-induced ototoxicity with extended high-frequency pure-tone audiometry or distortion-product otoacoustic emission.

    Science.gov (United States)

    Yu, Kwang Kyu; Choi, Chi Ho; An, Yong-Hwi; Kwak, Min Young; Gong, Soo Jung; Yoon, Sang Won; Shim, Hyun Joon

    2014-09-01

    To compare the effectiveness of monitoring cisplatin-induced ototoxicity in adult patients using extended high-frequency pure-tone audiometry (EHF-PTA) or distortion-product otoacoustic emission (DP-OAE) and to evaluate the concurrence of ototoxicity and nephrotoxicity in cisplatin-treated patients. EHF-PTA was measured at frequencies of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 9, 11.2, 12.5, 14, 16, 18, and 20 kHz and DP-OAE at frequencies of 0.5, 0.75, 1, 1.5, 2, 3, 4, 6, and 8 kHz in cisplatin-treated patients (n=10). Baseline evaluations were made immediately before chemotherapy and additional tests were performed before each of six cycles of cisplatin treatment. Laboratory tests to monitor nephrotoxicity were included before every cycle of chemotherapy. Four of 10 patients showed threshold changes on EHF-PTA. Five of 10 patients showed reductions in DP-OAE, but one was a false-positive result. The results of EHF-PTA and DP-OAE were consistent in two patients. Only one patient displayed nephrotoxicity on laboratory tests after the third cycle. In our study, the incidence rate of cisplatin-induced ototoxicity was 40% with EHF-PTA or DP-OAE. Although both EHF-PTA and DP-OAE showed the same sensitivity in detecting ototoxicity, they did not produce the same results in all patients. These two hearing tests could be used to complement one another. Clinicians should use both tests simultaneously in every cycle of chemotherapy to ensure the detection of ototoxicity.

  9. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  10. Impacts of rainfall features and antecedent soil moisture on occurrence of preferential flow: A study at hillslopes using high-frequency monitoring

    Science.gov (United States)

    Peng, Zhenyang; Tian, Fuqiang; Hu, Hongchang

    2016-04-01

    In order to evaluate influences of rainfall features and antecedent soil moisture on occurrence of preferential flow, a more than 2 years observation was conducted at 12 sites within a 7-km2 catchment, by applying the high-frequency monitoring approach. Totally 65 rainfall events were selected to compare among sites, and preferential flow was inferred when (i) responses of soil moisture did not follow a linear sequence with depth, and (ii) penetration velocity of wetting front in at least one horizon exceeded the threshold, which was set to be 5-10 times of the saturated hydraulic conductivity of soil matrix at different depths. Results showed that frequency of preferential flow was 40.7% in average, but varied from 17.9% to 74.3% among the sites. Correlations between the frequency and rainfall features, i.e. rainfall amount, duration, maximum and average intensity, were well fitted by logarithmic curves. Rainfall amount, which was most prominently correlated with frequency (R2=0.93), was regarded as the dominant driving factor of preferential flow, while average intensity was in second (R2=0.90). Antecedent soil moisture was also significantly correlated with the frequency. However, this should largely be attributed to the differences of soil moisture among sites, since varying range of soil moisture at a specific site was not wide enough to influence the frequency significantly. Further examination suggested that topography and surface cover (dead leaves and humus) were the controlling factors of both infiltration amount and occurrence of preferential flow, as water was more readily to infiltrate into soils and preferential flow was more readily to occur when slope gradient was small and surface cover was thick, while soil moisture was more likely to be a consequence of water storage capacity, rather than an inducer of preferential flow. This knowledge could be helpful in understanding the partitioning of surface runoff and infiltration, as well as runoff

  11. Brief communication "Monitoring ionospheric variations before earthquakes using the vertical and oblique sounding network over China"

    Directory of Open Access Journals (Sweden)

    Z. Wu

    2011-04-01

    Full Text Available The problem of earthquake prediction has stimulated the research for correlation between seismic activity and ionospheric anomaly. Many observations have shown the existence of anomaly of critical frequency of ionospheric F-region, foF2, before earthquake onset. Ionospheric sounding has been conducted routinely for more than 60 years in China by the China Research Institute of Radiowave Propagation (CRIRP, and deveoloped a very powerful ability to observe the ionosphere. In this paper, we briefly describe the anomalous variation of the foF2 before Ms8.0 Wenchuan earthquake (occurred on 12 May 2008 at 14:28 LT; 31.00° N, 103.40° E, which is a sign of the great interest arising in the seismo-ionospheric investigation of Chinese researchers. Furthermore, we introduce the routine work on seismo-ionospheric anomaly by the ground based high-resolution ionospheric observation (GBHIO network comprising 5 vertical and 20 oblique sounding stations.

  12. High Frequency Oscillatory Ventilation

    Directory of Open Access Journals (Sweden)

    AC Bryan

    1996-01-01

    Full Text Available High frequency oscillatory (HFO ventilation using low tidal volume and peak airway pressures is extremely efficient at eliminating carbon dioxide and raising pH in the newborn infant with acute respiratory failure. Improvement in oxygenation requires a strategy of sustained or repetitive inflations to 25 to 30 cm H2O in order to place the lung on the deflation limb of the pressure-volume curve. This strategy has also been shown to decrease the amount of secondary lung injury in animal models. Experience of the use of HFO ventilation as a rescue therapy as well as several published controlled trials have shown improved outcomes and a decrease in the use of extracorporeal membrane oxygenation when it has been used in newborns.

  13. Temperature monitored control system for high-frequency welded pipe and analysis of its influencing factors%高频焊管温度监控系统及其影响因素分析

    Institute of Scientific and Technical Information of China (English)

    何世权; 徐德怀; 樊丁; 徐德茹; 田禾

    2011-01-01

    针对高频焊管生产测量环境恶劣以及依靠经验观察来控制焊接温度的特点,提出高频焊管温度监控系统.该系统利用抗干扰强、测量精度高的比色测温仪采集焊接温度,通过LabVIEW控制高频电源的输出功率,实现温度调整,通过PID控制实现闭环控制.实验证明,监控系统能够准确检测高频焊管的焊接温度,并有效地提高温度的稳定性.最后提出影响高频焊管温度监控系统的因素.%Aimed at the poor measurement and production environment and dependence on empirical observation and control of welding temperature in the production of high-frequency welded pipe, a high-frequency welded pipe temperature monitored control system was proposed. In this system, a colorimetric pyrometer with strong anti-jamming and high measurement precision was used. By using software IabVIEW, the high-frequency power output was controlled to achieve temperature adjustment and closed-loop control. It was verified by test that the system could accurately detect the high-frequency welded pipe temperature, and effectively improve the temperature stability. Finally, the factors that influence the monitore control system of temperature of high-frequency welded pipe were suggested.

  14. High-frequency ECG

    Science.gov (United States)

    Tragardh, Elin; Schlegel, Todd T.

    2006-01-01

    The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire

  15. Monitoring microbe-induced physical property changes using high-frequency acoustic waveform data: Toward the development of a microbial megascope

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Kenneth Hurst

    2002-05-20

    A laboratory investigation was undertaken to determine the effect of microbe generated gas bubbles in controlled, saturated sediment columns utilizing a novel technique involving acoustic wave propagation. Specifically, the effect of denitrifying bacteria on saturated flow conditions was evaluated in light of the stimulated production of N{sub 2} gas and the resulting plugging of the pore throats. The propagation of high frequency acoustic waves through the sediment columns was used to locate those regions in the column where gas accumulation occurred. Over a period of six weeks, regions of gas accumulation resulted in the attenuation of acoustic wave energies with the decreases in amplitude typically greater than one order of magnitude.

  16. Monitoring microbe-induced physical property changes using high-frequency acoustic waveform data: Toward the development of a microbial megascope

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Kenneth Hurst [Univ. of California, Berkeley, CA (United States)

    2002-01-01

    A laboratory investigation was undertaken to determine the effect of microbe generated gas bubbles in controlled, saturated sediment columns utilizing a novel technique involving acoustic wave propagation. Specifically, the effect of denitrifying bacteria on saturated flow conditions was evaluated in light of the stimulated production of N2 gas and the resulting plugging of the pore throats. The propagation of high frequency acoustic waves through the sediment columns was used to locate those regions in the column where gas accumulation occurred. Over a period of six weeks, regions of gas accumulation resulted in the attenuation of acoustic wave energies with the decreases in amplitude typically greater than one order of magnitude.

  17. Using oblique digital photography for alluvial sandbar monitoring and low-cost change detection

    Science.gov (United States)

    Tusso, Robert B.; Buscombe, Daniel D.; Grams, Paul E.

    2015-01-01

    The maintenance of alluvial sandbars is a longstanding management interest along the Colorado River in Grand Canyon. Resource managers are interested in both the long-term trend in sandbar condition and the short-term response to management actions, such as intentional controlled floods released from Glen Canyon Dam. Long-term monitoring is accomplished at a range of scales, by a combination of annual topographic survey at selected sites, daily collection of images from those sites using novel, autonomously operating, digital camera systems (hereafter referred to as 'remote cameras'), and quadrennial remote sensing of sandbars canyonwide. In this paper, we present results from the remote camera images for daily changes in sandbar topography.

  18. The Implementation of a High-Frequency Radio Frequency Identification System with a Battery-Free Smart Tag for Orientation Monitoring

    Directory of Open Access Journals (Sweden)

    Tilen Svete

    2017-01-01

    Full Text Available Energy-harvesting passive RFID (radio frequency identification tags provide countless possibilities as so-called smart tags. Smart tags can communicate with existing RFID readers or interrogators while providing a battery-less platform for internal and external sensors to enrich available information about the environment and smart tag it. A reduced cost and size as well as an increased lifespan and durability of battery-free smart tags offer improvements in areas such as transportation and product tracking. Battery-free smart tags can ideally support arbitrarily complex sensor measurements, but in reality energy limitations can introduce great reductions in operating range and thus application range. In this work, we present an example application of a smart tag with a passive HF (high-frequency RFID tag IC (integrated circuit and MEMS (micro electro-mechanical structure sensor. A standard HF RFID reader connected to a PC (personal computer allowed the RF (radio frequency field to power and communicate with the smart tag. A Kalman filter, implemented on a PC, was used to correct and improve the raw sensor data of smart tag orientation. Measurement results showed that the MEMS sensor on the smart tag could be powered for continuous operation and that raw smart tag orientation data could be read while in the RF field of a standard HF RFID reader, but at a limited range.

  19. High-frequency monitoring of nitrogen and phosphorus response in three rural catchments to the end of the 2011-2012 drought in England

    Science.gov (United States)

    Outram, F. N.; Lloyd, C. E. M.; Jonczyk, J.; Benskin, C. McW. H.; Grant, F.; Perks, M. T.; Deasy, C.; Burke, S. P.; Collins, A. L.; Freer, J.; Haygarth, P. M.; Hiscock, K. M.; Johnes, P. J.; Lovett, A. L.

    2014-09-01

    This paper uses high-frequency bankside measurements from three catchments selected as part of the UK government-funded Demonstration Test Catchments (DTC) project. We compare the hydrological and hydrochemical patterns during the water year 2011-2012 from the Wylye tributary of the River Avon with mixed land use, the Blackwater tributary of the River Wensum with arable land use and the Newby Beck tributary of the River Eden with grassland land use. The beginning of the hydrological year was unusually dry and all three catchments were in states of drought. A sudden change to a wet summer occurred in April 2012 when a heavy rainfall event affected all three catchments. The year-long time series and the individual storm responses captured by in situ nutrient measurements of nitrate and phosphorus (total phosphorus and total reactive phosphorus) concentrations at each site reveal different pollutant sources and pathways operating in each catchment. Large storm-induced nutrient transfers of nitrogen and or phosphorus to each stream were recorded at all three sites during the late April rainfall event. Hysteresis loops suggested transport-limited delivery of nitrate in the Blackwater and of total phosphorus in the Wylye and Newby Beck, which was thought to be exacerbated by the dry antecedent conditions prior to the storm. The high rate of nutrient transport in each system highlights the scale of the challenges faced by environmental managers when designing mitigation measures to reduce the flux of nutrients to rivers from diffuse agricultural sources. It also highlights the scale of the challenge in adapting to future extreme weather events under a changing climate.

  20. Non-linear high-frequency waves in the magnetosphere

    Indian Academy of Sciences (India)

    S Moolla; R Bharuthram; S V Singh; G S Lakhina

    2003-12-01

    Using fluid theory, a set of equations is derived for non-linear high-frequency waves propagating oblique to an external magnetic field in a three-component plasma consisting of hot electrons, cold electrons and cold ions. For parameters typical of the Earth’s magnetosphere, numerical solutions of the governing equations yield sinusoidal, sawtooth or bipolar wave-forms for the electric field.

  1. High-frequency magnetic components

    CERN Document Server

    Kazimierczuk, Marian K

    2009-01-01

    If you are looking for a complete study of the fundamental concepts in magnetic theory, read this book. No other textbook covers magnetic components of inductors and transformers for high-frequency applications in detail. This unique text examines design techniques of the major types of inductors and transformers used for a wide variety of high-frequency applications including switching-mode power supplies (SMPS) and resonant circuits. It describes skin effect and proximity effect in detail to provide you with a sound understanding of high-frequency phenomena. As well as this, you will disco

  2. High-frequency seafloor acoustics

    National Research Council Canada - National Science Library

    Jackson, D. R; Richardson, M. D

    2007-01-01

    This title provides access to experimental data, theory, and models relevant to high-frequency seafloor acoustics and will be of interest to sonar engineers and researchers working in underwater acoustics...

  3. Geographies of High Frequency Trading

    DEFF Research Database (Denmark)

    Grindsted, Thomas Skou

    2016-01-01

    This paper investigates the geographies of high frequency trading. Today shares shift hands within micro seconds, giving rise to a form of financial geographies termed algorithmic capitalism. This notion refers to the different spatio-temporalities produced by high frequency trading, under...... the valuation of time. As high frequency trading accelerates financial markets, the paper examines the spatio-temporalities of automated trading by the ways in which the speed of knowledge exploitation in financial markets is not only of interest, but also the expansion between different temporalities....... The paper demonstrates how the intensification of time-space compression produces radical new dynamics in the financial market and develops information rent in HFT as convertible to a time rent and a spatio-temporal rent. The final section discusses whether high frequency trading only responds to crises...

  4. 机械故障信息监测MEMS高频加速度传感器%MEMS High-Frequency Accelerometers for Mechanical Fault Monitoring

    Institute of Scientific and Technical Information of China (English)

    赵玉龙; 刘岩; 孙禄

    2012-01-01

    结合机械故障信息监测的需求,将微机电系统(micro electro-mechanical system,简称MEMS)传感器技术引入到机械装备的振动测量中,介绍了压阻式MEMS加速度传感器的检测原理、结构设计、微加工工艺及其关键技术.以“小变形-大应力”为敏感结构设计思路,研制了梁膜结构、孔缝双桥结构以及复合多梁结构3种高频加速度传感器,以满足高速制造装备的振动信号监测对传感器的需求.通过静态、动态性能测试实验可以看出,3种结构均在一定程度上提升了传感器的测量性能,实际测振实验也说明所研制的MEMS加速度传感器具备了装备振动信号检测所需的功能.具有微型化、低成本以及可大规模生产潜力的MEMS传感器的发展为高端机械制造装备的发展提供了新的器件支持,推动主轴部件等的智能化、一体化发展.%Concerning the requirements of mechanical fault monitoring, the MEMS sensor technology is incorporated into the vibration detection in manufacturing equipment. The detailed parameters of MEMS piezoresistive accelerometers are introduced, including sensing mechanism, structural design, microma-chining process and key techniques. Using the proposal of large stress under little deformation, the cantilever-membrane structure, quad-slots-beam structure and multi-beam structure are proposed for high-performance accelerometers. The novel structures give an available solution to the trade-off between the measurement sensitivity and resonant frequency and obviously enhance the sensor characteristics. The results of sensor characterization and vibration detection show that the developed sensors can be used in the fault monitoring in manufacturing equipment. The MEMS sensors, featuring the potential for low cost and miniaturization, are promising to be the new sensing devices for advanced manufacturing equipment.

  5. Tracking the turbidity maximum zone in the Loire Estuary (France) based on a long-term, high-resolution and high-frequency monitoring network

    Science.gov (United States)

    Jalón-Rojas, Isabel; Schmidt, Sabine; Sottolichio, Aldo; Bertier, Christine

    2016-04-01

    A unique dataset of turbidity from 7 years of continuous monitoring at six stations, distributed evenly along a 62-km long transect, is presented to discuss, for the first time, the present-day dynamics of the turbidity maximum zone (TMZ) in the Loire Estuary. This system is considered one of the largest macrotidal, hyper-turbid estuaries of the European coast, mainly as the result of intense engineering works in the last two centuries. Besides accurate TMZ tracking, from tidal to multi-annual time scales, the high temporal and spatial resolution of measurements allows us to address TMZ aspects scarcely reported in the literature on estuarine sedimentary dynamics. In the Loire Estuary, TMZ moves upstream during periods of low discharge and its upstream boundary may reach up to 62 km from the mouth. The TMZ displacement is faster during its downstream flushing by river floods than during its upstream migration by tidal pumping (respectively 1.6 km day-1 and 0.9 km day-1 during 2011). However, the expulsion of the TMZ from the upper reaches requires higher discharge levels than its installation (respective discharge thresholds of 497-1034 m3 s-1 and 300-360 m3 s-1). This is due to the presence of mobile mud remaining after the TMZ presence, as confirmed by clockwise turbidity-discharge hysteresis patterns. While the installation threshold barely varies over years, the expulsion threshold is higher during years with a more concentrated and persistent TMZ. The interannual variability of the TMZ concentration and persistence is explained by the water volume transported during the previous high discharge period and the duration of the low discharge period, respectively, as recently shown for the Gironde Estuary, leading to a better understanding of TMZ features in macrotidal estuaries. The summer-averaged river flow is introduced as a hydrological indicator of the upstream boundary of the TMZ. In the context of global change, these three discharge-based indicators of TMZ

  6. High-frequency Trader Subjectivity

    DEFF Research Database (Denmark)

    Borch, Christian; Lange, Ann-Christina

    2017-01-01

    In this article, we examine the recent shift in financial markets toward high-frequency trading (HFT). This turn is being legitimized with reference to how algorithms are allegedly more rational and efficient than human traders, and less prone to emotionally motivated decisions. We argue...... that although HFT does not render humans irrelevant, it is leading to a reconfiguration of both the ideal trading subject and the human–machine relations. Drawing on interviews with and ethnographic observations of high-frequency traders, as well as HFT ‘how to’ books, we analyze the subjectivity and self......-techniques of the ideal high-frequency trader. We demonstrate that these traders face the challenge of avoiding emotional interference in their algorithms and that they deploy a set of disciplinary self-techniques to curb the importance of emotional attachment....

  7. High-frequency complex pitch

    DEFF Research Database (Denmark)

    Santurette, Sébastien; Dau, Torsten

    2012-01-01

    Harmonics in a complex tone are typically considered unresolved when they interact with neighboring harmonics in the cochlea and cannot be heard out separately. Recent studies have suggested that the low pitch evoked by unresolved high-frequency harmonics may be coded via temporal fine-structure ......Harmonics in a complex tone are typically considered unresolved when they interact with neighboring harmonics in the cochlea and cannot be heard out separately. Recent studies have suggested that the low pitch evoked by unresolved high-frequency harmonics may be coded via temporal fine...

  8. High-Frequency Seafloor Acoustics

    CERN Document Server

    Jackson, Darrell R

    2007-01-01

    High-Frequency Seafloor Acoustics is the first book in a new series sponsored by the Office of Naval Research on the latest research in underwater acoustics. This exciting new title provides ready access to experimental data, theory, and models relevant to high-frequency seafloor acoustics and will be of interest to sonar engineers and researchers working in underwater acoustics. The physical characteristics of the seafloor affecting acoustic propagation and scattering are covered, including physical and geoacoustic properties and surface roughness. Current theories for acoustic propagation in sediments are presented along with corresponding models for reflection, scattering, and seafloor penetration. The main text is backed up by an extensive bibliography and technical appendices.

  9. High frequency trading and fragility

    OpenAIRE

    Cespa, Giovanni; Vives, Xavier

    2017-01-01

    We show that limited dealer participation in the market, coupled with an informational friction resulting from high frequency trading, can induce demand for liquidity to be upward sloping and strategic complementarities in traders’ liquidity consumption decisions: traders demand more liquidity when the market becomes less liquid, which in turn makes the market more illiquid, fostering the initial demand hike. This can generate market instability, where an initial dearth of liquidity degenerat...

  10. High-frequency magnetic components

    CERN Document Server

    Kazimierczuk, Marian K

    2013-01-01

    A unique text on the theory and design fundaments of inductors and transformers, updated with more coverage on the optimization of magnetic devices and many new design examples The first edition is popular among a very broad audience of readers in different areas of engineering and science. This book covers the theory and design techniques of the major types of high-frequency power inductors and transformers for a variety of applications, including switching-mode power supplies (SMPS) and resonant dc-to-ac power inverters and dc-to-dc power converters. It describes eddy-current phenomena (su

  11. High frequency mesozooplankton monitoring: Can imaging systems and automated sample analysis help us describe and interpret changes in zooplankton community composition and size structure — An example from a coastal site

    Science.gov (United States)

    Romagnan, Jean Baptiste; Aldamman, Lama; Gasparini, Stéphane; Nival, Paul; Aubert, Anaïs; Jamet, Jean Louis; Stemmann, Lars

    2016-10-01

    The present work aims to show that high throughput imaging systems can be useful to estimate mesozooplankton community size and taxonomic descriptors that can be the base for consistent large scale monitoring of plankton communities. Such monitoring is required by the European Marine Strategy Framework Directive (MSFD) in order to ensure the Good Environmental Status (GES) of European coastal and offshore marine ecosystems. Time and cost-effective, automatic, techniques are of high interest in this context. An imaging-based protocol has been applied to a high frequency time series (every second day between April 2003 to April 2004 on average) of zooplankton obtained in a coastal site of the NW Mediterranean Sea, Villefranche Bay. One hundred eighty four mesozooplankton net collected samples were analysed with a Zooscan and an associated semi-automatic classification technique. The constitution of a learning set designed to maximize copepod identification with more than 10,000 objects enabled the automatic sorting of copepods with an accuracy of 91% (true positives) and a contamination of 14% (false positives). Twenty seven samples were then chosen from the total copepod time series for detailed visual sorting of copepods after automatic identification. This method enabled the description of the dynamics of two well-known copepod species, Centropages typicus and Temora stylifera, and 7 other taxonomically broader copepod groups, in terms of size, biovolume and abundance-size distributions (size spectra). Also, total copepod size spectra underwent significant changes during the sampling period. These changes could be partially related to changes in the copepod assemblage taxonomic composition and size distributions. This study shows that the use of high throughput imaging systems is of great interest to extract relevant coarse (i.e. total abundance, size structure) and detailed (i.e. selected species dynamics) descriptors of zooplankton dynamics. Innovative

  12. Characterizing seasonal variability of storm events based on very high frequency monitoring of hydrological and chemical variables: comparing patterns in hot spots and hot moments for nutrient and sediment export

    Science.gov (United States)

    Fovet, Ophelie; Thelusma, Gilbert; Humbert, Guillaume; Dupas, Rémi; Faucheux, Mikael; Gilliet, Nicolas; Hamon, Yannick; Jaffrezic, Anne; Grimaldi, Catherine; Gruau, Gerard

    2016-04-01

    Storm events are critical hot moments of emission for several dissolved and particulate chemical species at major stake for water quality (e.g. dissolved organic carbon DOC, suspended sediments, phosphorus). During such events, the solutes or particles are exported from heterogeneous sources through various pathways to stream leading to specific integrated signals at the outlet characterized by very short dynamics. This is merely true in headwater catchments where the total duration of such events ranges over 10h to 3 days, with very quick variations in stream flow and concentrations at the outlet occurring in a few hours. Thus for investigating properly event processes, high frequency monitoring of flow and water quality is required. We analysed 103 storm events in a 5 km2 agricultural headwater catchment, part of the AgrHys Observatory, on the basis of a 3-year-long data set which combined meterological (Rainfall), hydrological (flow and piezometry), and water quality (turbidity, conductivity, DOC and NO3 concentrations) data recorded at very high frequencies (from 1 to 20 min) thanks to dedicated sensors. We proposed a range of quantitative storm descriptors for characterizing input (rainfall), antecedent and initial conditions (groundwater levels and saturated area), and stream response in terms of level and dynamics of flow (Q), groundwater levels, and concentrations (C) but also the C-Q relationships. Three intra annual periods have been previously defined for base flow dynamic according to shallow groundwater table variations so that they correspond to different connectivity status in the catchment. The seasonal and inter-annual variability of the storm events have been analysed using the descriptors and based on these predefined periods. Results show that the hydrological flowpaths and the consequent storm chemistry were controlled by the hydrological base flow regime rather than by the rain input characteristics. This highlights that the exports of NO3

  13. High frequency welded (ERW) casing

    Energy Technology Data Exchange (ETDEWEB)

    Duisberg, J. (Hoesch Roehrenwerke A.G., Hamm (Germany, F.R.))

    1980-09-01

    Due to the up-to-date standard in welding and testing techniques, the significance of ERW-casing is growing rapidly. The basic items of ERW-pipe are explained in detail. The forming mechanism, the high frequency welding by induction and contact welding processes is explained in detail as well as destructive and non-destructive testing methods. Finishing the ends as threading, thread control (gauging), power tight connection, pressure test and final quality control are rounding up the picture of the production of ERW-casing. Last but not least the test results from the joint strength- and collapse tests which are of outstanding interest for casings, are compared with API requirements in order to demonstrate compliance with API requirements.

  14. Cross-correlation and time-lag analysis of high frequency monitoring data of the Vallcebre landslide (Eastern Pyrenees, Spain) to reveal cause-effect relationships between variables governing slope instability

    Science.gov (United States)

    Mulas, Marco; Moya, Jose; Corsini, Alessandro; Corominas, Jordi

    2015-04-01

    The Vallcebre landslide is a slow moving large landslide located 140 km north of Barcelona in the Eastern Pyrenees. Monitoring data of the Vallcebre landslide represent a singular case of multi parameter high-frequency monitoring system set up in 1996 and still ongoing. Data of movements and groundwater levels are measured and recorded with a frequency of 20 minutes in 6 boreholes distributed in the landslide, each one equipped with a wire extensometer and a piezometer, while rainfall is recorded by a specific gauge at the site. Data from 3 boreholes recorded during three full years of measurements (from 1999 to 2001) have been analyzed by means of a cross-correlation function in order to determine the reciprocal interdependency and the relative time lag between rainfall, groundwater and movement rate maxima and, ultimately, to evidence cause-effect processes occurring along the slope. It should be pinpointed that, in this specific case, rainfall is also a proxy for the discharge level of the stream eroding the toe of the landslide, that is believed to be one of the main instability factors. The cross-correlation function is a quite simple signal processing tool for measuring similarities of waveforms as function of an applied time-lag. Specifically, it was applied to study: i) the relations between rainfall and movement rate, so to highlight the relative time lag for rainfall to produce an effect in different points of the landslide; ii) the inter-dependencies between different movement rates in the three boreholes in order to determine the pattern of mobilization of the landslide (from up to down slope and vice-versa); iii) the response of groundwater with respect to rainfall, which reflects the local permeability; iv) the evolution of groundwater levels in the three monitoring points. Altogether, results confirm and constrain in time the retrogressive trend of movements in the landslide (in agreement with a 2D numerical model previously developed by Ferrari et

  15. High Frequency Linacs for Hadrontherapy

    Science.gov (United States)

    Amaldi, Ugo; Braccini, Saverio; Puggioni, Paolo

    The use of radiofrequency linacs for hadrontherapy was proposed about 20 years ago, but only recently has it been understood that the high repetition rate together with the possibility of very rapid energy variations offers an optimal solution to the present challenge of hadrontherapy: "paint" a moving tumor target in three dimensions with a pencil beam. Moreover, the fact that the energy, and thus the particle range, can be electronically adjusted implies that no absorber-based energy selection system is needed, which, in the case of cyclotron-based centers, is the cause of material activation. On the other side, a linac consumes less power than a synchrotron. The first part of this article describes the main advantages of high frequency linacs in hadrontherapy, the early design studies, and the construction and test of the first high-gradient prototype which accelerated protons. The second part illustrates some technical issues relevant to the design of copper standing wave accelerators, the present developments, and two designs of linac-based proton and carbon ion facilities. Superconductive linacs are not discussed, since nanoampere currents are sufficient for therapy. In the last two sections, a comparison with circular accelerators and an overview of future projects are presented.

  16. Econometrics of financial high-frequency data

    CERN Document Server

    Hautsch, Nikolaus

    2011-01-01

    This book covers major approaches in high-frequency econometrics. It discusses implementation details, provides insights into properties of high-frequency data as well as institutional settings and presents applications.

  17. High Frequency Chandler Wobble Excitation

    Science.gov (United States)

    Seitz, F.; Stuck, J.; Thomas, M.

    2003-04-01

    and OMCT forcing fields give no hint for increased excitation power in the Chandler band. Thus it is assumed, that continuous high frequency excitation due to stochastic weather phenomena is responsible for the perpetuation of the Chandler wobble.

  18. State Monitoring of High-Frequency Electric Resistance Welding Based on Digital Image Technology%基于数字图像技术的高频电阻焊状态监测

    Institute of Scientific and Technical Information of China (English)

    王会峰; 李云龙; 李记科

    2012-01-01

    为实现对高频电阻焊焊接过程的在线实时监测,通过对焊接现象、焊接缺陷及其成因的分析,提出了一种基于高速CCD成像和数字图像处理的焊接过程自动化监测方法.该方法利用架设在焊接区域上部的高速CCD相机获取焊接区的数字图像,通过对焊接区图像的特征加热面积、V型开口角大小、焊接熔合点位置、加热区对称度等多个参数的提取和测量,获取焊接区的多特征参数,然后将这些参数进行数据融合,得到当前的焊接状态.在图像处理中应用了基于非平衡R-G-B填充的抗干扰分割算法、基于直线拟合的V型角开口角大小及角分线检测算法,设计了面积对称度评价函数及基于BP神经网络的多特征融合模型.通过现场实验发现:文中方法能够有效监测焊接区的状态,有利于焊接质量控制.%In order to realize the real-time and on-line state monitoring of the high-frequency electric resistance welding (HF-ERW) , according to the analytical results of various welding phenomena as well as the welding defects and their causes, an automatic monitoring method based on the high-speed CCD imaging and the digital image processing is proposed. In this method, digital images of the welding region are obtained by using a CCD camera set on a fixed location above the welding region, and the parameters, such as the characteristic heating area, the value of V-type angle, the location of welding bond point and the symmetry degree of the heating region, are measured and processed through a multi-characteristic fusion, thus revealing the current welding state. Moreover, during the image processing, a new segmentation algorithm based on R-G-B non-equilibrium anti-inlerference technology is employed, the V-type angle detection and the corresponding bisection algorithm based on line fitting are adopted, a function to evaluate the symmetry degree of the heating region is designed, and a multi

  19. 78 FR 70567 - Nationwide Use of High Frequency and Ultra High Frequency Active SONAR Technology; Final...

    Science.gov (United States)

    2013-11-26

    ...] Nationwide Use of High Frequency and Ultra High Frequency Active SONAR Technology; Final Programmatic... Programmatic Environmental Assessment (PEA) for the Nationwide Use of High Frequency (HF) and Ultra High Frequency (UHF) Sound Navigation and Ranging (SONAR) Technology and Finding of No Significant Impact (FONSI...

  20. Overview of the Advanced High Frequency Branch

    Science.gov (United States)

    Miranda, Felix A.

    2015-01-01

    This presentation provides an overview of the competencies, selected areas of research and technology development activities, and current external collaborative efforts of the NASA Glenn Research Center's Advanced High Frequency Branch.

  1. MACS-Himalaya: A photogrammetric aerial oblique camera system designed for highly accurate 3D-reconstruction and monitoring in steep terrain and under extreme illumination conditions

    Science.gov (United States)

    Brauchle, Joerg; Berger, Ralf; Hein, Daniel; Bucher, Tilman

    2017-04-01

    The DLR Institute of Optical Sensor Systems has developed the MACS-Himalaya, a custom built Modular Aerial Camera System specifically designed for the extreme geometric (steep slopes) and radiometric (high contrast) conditions of high mountain areas. It has an overall field of view of 116° across-track consisting of a nadir and two oblique looking RGB camera heads and a fourth nadir looking near-infrared camera. This design provides the capability to fly along narrow valleys and simultaneously cover ground and steep valley flank topography with similar ground resolution. To compensate for extreme contrasts between fresh snow and dark shadows in high altitudes a High Dynamic Range (HDR) mode was implemented, which typically takes a sequence of 3 images with graded integration times, each covering 12 bit radiometric depth, resulting in a total dynamic range of 15-16 bit. This enables dense image matching and interpretation for sunlit snow and glaciers as well as for dark shaded rock faces in the same scene. Small and lightweight industrial grade camera heads are used and operated at a rate of 3.3 frames per second with 3-step HDR, which is sufficient to achieve a longitudinal overlap of approximately 90% per exposure time at 1,000 m above ground at a velocity of 180 km/h. Direct georeferencing and multitemporal monitoring without the need of ground control points is possible due to the use of a high end GPS/INS system, a stable calibrated inner geometry of the camera heads and a fully photogrammetric workflow at DLR. In 2014 a survey was performed on the Nepalese side of the Himalayas. The remote sensing system was carried in a wingpod by a Stemme S10 motor glider. Amongst other targets, the Seti Valley, Kali-Gandaki Valley and the Mt. Everest/Khumbu Region were imaged at altitudes up to 9,200 m. Products such as dense point clouds, DSMs and true orthomosaics with a ground pixel resolution of up to 15 cm were produced in regions and outcrops normally inaccessible to

  2. Obliquity along plate boundaries

    Science.gov (United States)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  3. High frequency group pulse electrochemical machining

    Institute of Scientific and Technical Information of China (English)

    WU Gaoyang; ZHANG Zhijing; ZHANG Weimin; TANG Xinglun

    2007-01-01

    In the process of machining ultrathin metal structure parts,the signal composition of high frequency group pulse,the influence of frequency to reverse current,and the design of the cathode in high frequency group pulse electrochemical machining (HGPECM) are discussed.The experiments on process were carried out.Results indicate that HGPECM can greatly improve the characteristics of the inter-electrode gap flow field,reduce electrode passivation,and obtain high machining quality.The machining quality is obviously improved by increasing the main pulse frequency.The dimensional accuracy reaches 30-40 pro and the roughness attained is at 0.30-0.35 μm.High frequency group pulse electrochemical machining can be successfully used in machining micro-parts.

  4. Ionospheric Heating with Oblique Waves. Volume 2. Applications to High-Frequency Radio Propagation

    Science.gov (United States)

    1989-08-01

    iutengsitV. Several points must he stressed. First. the geometrica I1ptics fieid intensity becomes unbounded at the skip distance, hoth at the interior...March-April 1988, pp. 171-182. 13. Buckley, R., "On the Calculation of Intensity in Dispersive Inhomogenous Media in the Ray Approximation," Proc. R

  5. Estimating gravity wave parameters from oblique high-frequency backscatter: Modeling and analysis

    Science.gov (United States)

    Bristow, W. A.; Greenwald, R. A.

    1995-01-01

    A new technique for estimating electron density perturbation amplitudes of traveling ionospheric disturbances (TIDs), using HF radar data, is presented. TIDs are observed in HF radar data as enhancements of the ground-scattered power which propagate through the radar's field of view. These TIDs are the ionospheric manifestation of atmospheric acoustic-gravity waves. TID electron density perturbation amplitudes were estimated by simulating the radar returns, using HF ray tracing through a model ionosphere perturbed by a model gravity wave. The simulation determined the return power in the ground-scattered portion of the signal as a function of range, and this was compared to HF radar data from the Goose Bay HF radar at a time when evidence of gravity waves was present in the data. By varying the amplitude of the electron density perturbation in the model it was possible to estimate the perturbation of the actual wave. It was found that the perturbations that are observed by the Goose Bay HF radar are of the order of 20% to 35%. It was also found that the number of observable power enhancements, and the relative amplitudes of these enhancements, depended on the vertical thickness of the gravity wave's source region. From the simulations and observations it was estimated that the source region for the case presented here was approximately 20 km thick. In addition, the energy in the wave packet was calculated and compared to an estimate of the available energy in the source region. It was found that the wave energy was about 0.2% of the estimated available source region energy.

  6. High frequency and pulse scattering physical acoustics

    CERN Document Server

    Pierce, Allan D

    1992-01-01

    High Frequency and Pulse Scattering investigates high frequency and pulse scattering, with emphasis on the phenomenon of echoes from objects. Geometrical and catastrophe optics methods in scattering are discussed, along with the scattering of sound pulses and the ringing of target resonances. Caustics and associated diffraction catastrophes are also examined.Comprised of two chapters, this volume begins with a detailed account of geometrically based approximation methods in scattering theory, focusing on waves transmitted through fluid and elastic scatterers and glory scattering; surface ray r

  7. High frequency pressure oscillator for microcryocoolers

    NARCIS (Netherlands)

    Vanapalli, Srinivas; ter Brake, Hermanus J.M.; Jansen, Henricus V.; Zhao, Yiping; Holland, Herman J.; Burger, Johannes Faas; Elwenspoek, Michael Curt

    2008-01-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency

  8. Investigation of high-frequency pipe welding

    Science.gov (United States)

    Konovalov, Nikolai A.; Lakhno, Nikolay I.; Gushchin, A. G.; Putryk, N. D.; Kovalenko, Vladimir I.; Galkina, V. A.; Veselovsky, Vladimir B.; Furmanov, Valeri B.; Kovika, Nikolai D.; Novikov, Leonid V.; Shcherbina, V. N.

    1993-01-01

    For investigation of a pipe welding process at high-frequency heating aimed at increasing of pipe quality and decreasing of spoilage, the use of high-speed recording and TV-technique is considered to be effective. The authors have created a visual inspection system for pipe welding process studies at a tube mill of the Novomoskovsk Pipe Plant.

  9. High frequency dynamics in centrifugal compressors

    NARCIS (Netherlands)

    Twerda, A.; Meulendijks, D.; Smeulers, J.P.M.; Handel, R. van den; Lier, L.J. van

    2008-01-01

    Problems with centrifugal compressors relating to high frequency, i.e. Blade passing frequency (BPF) are increasing. Pulsations and vibrations generated in centrifugal compressors can lead to nuisance, due to strong tonal noise, and even breakdown. In several cases the root cause of a failure or a

  10. High frequency pressure oscillator for microcryocoolers

    NARCIS (Netherlands)

    Vanapalli, Srinivas; ter Brake, Hermanus J.M.; Jansen, Henricus V.; Zhao, Yiping; Holland, Herman J.; Burger, Johannes Faas; Elwenspoek, Michael Curt

    2008-01-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pre

  11. High frequency dynamics in centrifugal compressors

    NARCIS (Netherlands)

    Twerda, A.; Meulendijks, D.; Smeulers, J.P.M.; Handel, R. van den; Lier, L.J. van

    2008-01-01

    Problems with centrifugal compressors relating to high frequency, i.e. Blade passing frequency (BPF) are increasing. Pulsations and vibrations generated in centrifugal compressors can lead to nuisance, due to strong tonal noise, and even breakdown. In several cases the root cause of a failure or a n

  12. High Frequency Trading, Information, and Takeovers

    NARCIS (Netherlands)

    Humphery-Jenner, M.

    2011-01-01

    This paper (1) proposes new variables to detect informed high-frequency trading (HFT), (2) shows that HFT can help to predict takeover targets, and (3) shows that HFT in uences target announcement announcement returns. Prior literature suggests that informed trade may occur before takeovers, but has

  13. High frequency pressure oscillator for microcryocoolers

    NARCIS (Netherlands)

    Vanapalli, S.; Brake, ter H.J.M.; Jansen, H.V.; Zhao, Y.; Holland, H.J.; Burger, J.F.; Elwenspoek, M.C.

    2008-01-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pre

  14. Essays on high frequency financial econometrics

    NARCIS (Netherlands)

    X. Yang

    2015-01-01

    It has long been demonstrated that continuous-time methods are powerful tools in financial modeling. Yet only in recent years, their counterparts in empirical analysis—high frequency econometrics—began to emerge with the availability of intra-day data and relevant statistical tools. This dissertatio

  15. Essays on high frequency financial econometrics

    NARCIS (Netherlands)

    Yang, X.

    2015-01-01

    It has long been demonstrated that continuous-time methods are powerful tools in financial modeling. Yet only in recent years, their counterparts in empirical analysis—high frequency econometrics—began to emerge with the availability of intra-day data and relevant statistical tools. This

  16. Advanced Extremely High Frequency Satellite (AEHF)

    Science.gov (United States)

    2015-12-01

    High Frequency Satellite (AEHF) is a joint service satellite communications system that provides global , survivable, secure, protected, and jam...three satellites fully integrated into the Milstar constellation. October 2014: On October 16, 2014, the program received PEO certification for the...Combined Orbital Operation, Logistics Sustainment ( COOLS ) contract, it will be completed and coordinated in CY 2016. The AEHF system being sustained

  17. High frequency III-V nanowire MOSFETs

    Science.gov (United States)

    Lind, Erik

    2016-09-01

    III-V nanowire transistors are promising candidates for very high frequency electronics applications. The improved electrostatics originating from the gate-all-around geometry allow for more aggressive scaling as compared with planar field-effect transistors, and this can lead to device operation at very high frequencies. The very high mobility possible with In-rich devices can allow very high device performance at low operating voltages. GaN nanowires can take advantage of the large band gap for high voltage operation. In this paper, we review the basic physics and device performance of nanowire field- effect transistors relevant for high frequency performance. First, the geometry of lateral and vertical nanowire field-effect transistors is introduced, with special emphasis on the parasitic capacitances important for nanowire geometries. The basic important high frequency transistor metrics are introduced. Secondly, the scaling properties of gate-all-around nanowire transistors are introduced, based on geometric length scales, demonstrating the scaling possibilities of nanowire transistors. Thirdly, to model nanowire transistor performance, a two-band non-parabolic ballistic transistor model is used to efficiently calculate the current and transconductance as a function of band gap and nanowire size. The intrinsic RF metrics are also estimated. Finally, experimental state-of-the-art nanowire field-effect transistors are reviewed and benchmarked, lateral and vertical transistor geometries are explored, and different fabrication routes are highlighted. Lateral devices have demonstrated operation up to 350 GHz, and vertical devices up to 155 GHz.

  18. High Frequency Trading, Information, and Takeovers

    NARCIS (Netherlands)

    Humphery-Jenner, M.

    2011-01-01

    This paper (1) proposes new variables to detect informed high-frequency trading (HFT), (2) shows that HFT can help to predict takeover targets, and (3) shows that HFT in uences target announcement announcement returns. Prior literature suggests that informed trade may occur before takeovers, but has

  19. Parametric Study of High Frequency Pulse Detonation Tubes

    Science.gov (United States)

    Cutler, Anderw D.

    2008-01-01

    This paper describes development of high frequency pulse detonation tubes similar to a small pulse detonation engine (PDE). A high-speed valve injects a charge of a mixture of fuel and air at rates of up to 1000 Hz into a constant area tube closed at one end. The reactants detonate in the tube and the products exit as a pulsed jet. High frequency pressure transducers are used to monitor the pressure fluctuations in the device and thrust is measured with a balance. The effects of injection frequency, fuel and air flow rates, tube length, and injection location are considered. Both H2 and C2H4 fuels are considered. Optimum (maximum specific thrust) fuel-air compositions and resonant frequencies are identified. Results are compared to PDE calculations. Design rules are postulated and applications to aerodynamic flow control and propulsion are discussed.

  20. High-current, high-frequency capacitors

    Science.gov (United States)

    Renz, D. D.

    1983-06-01

    The NASA Lewis high-current, high-frequency capacitor development program was conducted under a contract with Maxwell Laboratories, Inc., San Diego, California. The program was started to develop power components for space power systems. One of the components lacking was a high-power, high-frequency capacitor. Some of the technology developed in this program may be directly usable in an all-electric airplane. The materials used in the capacitor included the following: the film is polypropylene, the impregnant is monoisopropyl biphenyl, the conductive epoxy is Emerson and Cuming Stycast 2850 KT, the foil is aluminum, the case is stainless steel (304), and the electrode is a modified copper-ceramic.

  1. High frequency conductivity in carbon nanotubes

    Directory of Open Access Journals (Sweden)

    S. S. Abukari

    2012-12-01

    Full Text Available We report on theoretical analysis of high frequency conductivity in carbon nanotubes. Using the kinetic equation with constant relaxation time, an analytical expression for the complex conductivity is obtained. The real part of the complex conductivity is initially negative at zero frequency and become more negative with increasing frequency, until it reaches a resonance minimum at ω ∼ ωB for metallic zigzag CNs and ω < ωB for armchair CNs. This resonance enhancement is indicative for terahertz gain without the formation of current instabilities induced by negative dc conductivity. We noted that due to the high density of states of conduction electrons in metallic zigzag carbon nanotubes and the specific dispersion law inherent in hexagonal crystalline structure result in a uniquely high frequency conductivity than the corresponding values for metallic armchair carbon nanotubes. We suggest that this phenomenon can be used to suppress current instabilities that are normally associated with a negative dc differential conductivity.

  2. Mars Obliquity Cycle Illustration

    Science.gov (United States)

    2008-01-01

    The tilt of Mars' spin axis (obliquity) varies cyclically over hundreds of thousands of years, and affects the sunlight falling on the poles. Because the landing site of NASA's Phoenix Mars Lander is so near the north pole, higher sun and warmer temperatures during high obliquity lead to warmer, more humid surface environments, and perhaps thicker, more liquid-like films of water in soil. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  3. High-Frequency Percussive Ventilation Revisited

    Science.gov (United States)

    2010-01-01

    physiologic and clin- ical outcomes. Pediatric and adult inhalational injury studies have linked HFPV to an improvement in static lung compliance...sedation–analgesic combinations (usually fentanyl with the individual or combined use of midazolam and propofol and/or dexmedetomidine), patient...1998;84:1174–7. 34. Frantz ID III, Close RH. Alveolar pressure swings during high frequency ventilation in rabbits. Pediatr Res 1985;19:162–6. 35. Pillow

  4. Extremely high frequency RF effects on electronics.

    Energy Technology Data Exchange (ETDEWEB)

    Loubriel, Guillermo Manuel; Vigliano, David; Coleman, Phillip Dale; Williams, Jeffery Thomas; Wouters, Gregg A.; Bacon, Larry Donald; Mar, Alan

    2012-01-01

    The objective of this work was to understand the fundamental physics of extremely high frequency RF effects on electronics. To accomplish this objective, we produced models, conducted simulations, and performed measurements to identify the mechanisms of effects as frequency increases into the millimeter-wave regime. Our purpose was to answer the questions, 'What are the tradeoffs between coupling, transmission losses, and device responses as frequency increases?', and, 'How high in frequency do effects on electronic systems continue to occur?' Using full wave electromagnetics codes and a transmission-line/circuit code, we investigated how extremely high-frequency RF propagates on wires and printed circuit board traces. We investigated both field-to-wire coupling and direct illumination of printed circuit boards to determine the significant mechanisms for inducing currents at device terminals. We measured coupling to wires and attenuation along wires for comparison to the simulations, looking at plane-wave coupling as it launches modes onto single and multiconductor structures. We simulated the response of discrete and integrated circuit semiconductor devices to those high-frequency currents and voltages, using SGFramework, the open-source General-purpose Semiconductor Simulator (gss), and Sandia's Charon semiconductor device physics codes. This report documents our findings.

  5. Ionospheric modifications in high frequency heating experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, Spencer P. [Department of Electrical and Computer Engineering, Polytechnic School of Engineering, New York University, 5 MetroTech Center, Brooklyn, New York 11201 (United States)

    2015-01-15

    Featured observations in high-frequency (HF) heating experiments conducted at Arecibo, EISCAT, and high frequency active auroral research program are discussed. These phenomena appearing in the F region of the ionosphere include high-frequency heater enhanced plasma lines, airglow enhancement, energetic electron flux, artificial ionization layers, artificial spread-F, ionization enhancement, artificial cusp, wideband absorption, short-scale (meters) density irregularities, and stimulated electromagnetic emissions, which were observed when the O-mode HF heater waves with frequencies below foF2 were applied. The implication and associated physical mechanism of each observation are discussed and explained. It is shown that these phenomena caused by the HF heating are all ascribed directly or indirectly to the excitation of parametric instabilities which instigate anomalous heating. Formulation and analysis of parametric instabilities are presented. The results show that oscillating two stream instability and parametric decay instability can be excited by the O-mode HF heater waves, transmitted from all three heating facilities, in the regions near the HF reflection height and near the upper hybrid resonance layer. The excited Langmuir waves, upper hybrid waves, ion acoustic waves, lower hybrid waves, and field-aligned density irregularities set off subsequent wave-wave and wave-electron interactions, giving rise to the observed phenomena.

  6. Significance of High-frequency Electrical Brain Activity.

    Science.gov (United States)

    Kobayashi, Katsuhiro; Akiyama, Tomoyuki; Agari, Takashi; Sasaki, Tatsuya; Shibata, Takashi; Hanaoka, Yoshiyuki; Akiyama, Mari; Endoh, Fumika; Oka, Makio; Date, Isao

    2017-06-01

     Electroencephalogram (EEG) data include broadband electrical brain activity ranging from infra-slow bands (frequency bands (e.g., the approx. 10 Hz alpha rhythm) to high-frequency bands of up to 500 Hz. High-frequency oscillations (HFOs) including ripple and fast ripple oscillations (80-200 Hz and>200 / 250 Hz, respectively) are particularly of note due to their very close relationship to epileptogenicity, with the possibility that they could function as a surrogate biomarker of epileptogenicity. In contrast, physiological high-frequency activity plays an important role in higher brain functions, and the differentiation between pathological / epileptic and physiological HFOs is a critical issue, especially in epilepsy surgery. HFOs were initially recorded with intracranial electrodes in patients with intractable epilepsy as part of a long-term invasive seizure monitoring study. However, fast oscillations (FOs) in the ripple and gamma bands (40-80 Hz) are now noninvasively detected by scalp EEG and magnetoencephalography, and thus the scope of studies on HFOs /FOs is rapidly expanding.

  7. Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

    Science.gov (United States)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2009-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  8. High-Frequency Rayleigh-Wave Method

    Institute of Scientific and Technical Information of China (English)

    Jianghai Xia; Richard D Millerg; Xu Yixian; Luo Yinhe; Chen Chao; Liu Jiangping; Julian Ivanov; Chong Zeng

    2009-01-01

    High-frequency (≥2 Hz) Rayleigh-wave data acquired with a multichannei recording sys-tem have been utilized to determine shear (S)-wave velocities in near-surface geophysics since the early 1980s. This overview article discusses the main research results of high-frequency surface-wave tech-niques achieved by research groups at the Kansas Geological Survey and China University of Geosciences in the last 15 years. The multichannel analysis of surface wave (MASW) method is a nou-iuvasive acoustic approach to estimate near-surface S-wave velocity. The differences between MASW results and direct borehole measurements are approximately 15% or less and random. Studies show that simultaneous inversion with higher modes and the fundamental mode can increase model resolution and an investigation depth. The other important seismic property, quality factor (Q), can also be estimated with the MASW method by inverting attenuation coefficients of Rayleigh waves. An inverted model (S-wave velocity or Q) obtained using a damped least-squares method can be assessed by an optimal damping vector in a vicinity of the inverted model determined by an objective function, which is the trace of a weighted sum of model-resolution and model-covariance matrices. Current developments include modeling high-frequency Rayleigh-waves in near-surface media, which builds a foundation for shallow seismic or Rayleigh-wave inversion in the time-offset domain; imaging dispersive energy with high resolution in the frequency-velocity domain and possibly with data in an arbitrary acquisition geometry, which opens a door for 3D surface-wave techniques; and successfully separating surface-wave modes, which provides a valuable tool to perform S-wave velocity profiling with high-horizontal resolution.

  9. Evolution of Very High Frequency Power Supplies

    DEFF Research Database (Denmark)

    Knott, Arnold; Andersen, Toke Meyer; Kamby, Peter

    2013-01-01

    in radio frequency transmission equipment helps to overcome those. However those circuits were not designed to meet the same requirements as power converters. This paper summarizes the contributions in recent years in application of very high frequency (VHF) technologies in power electronics, shows results......The ongoing demand for smaller and lighter power supplies is driving the motivation to increase the switching frequencies of power converters. Drastic increases however come along with new challenges, namely the increase of switching losses in all components. The application of power circuits used...

  10. Advances in Very High Frequency Power Conversion

    DEFF Research Database (Denmark)

    Kovacevic, Milovan

    . Excellent performance and small size of magnetic components and capacitors at very high frequencies, along with constant advances in performance of power semiconductor devices, suggests a sizable shift in consumer power supplies market into this area in the near future. To operate dc-dc converter power...... to be applied, especially at low power levels where gating loss becomes a significant percentage of the total loss budget. Various resonant gate drive methods have been proposed to address this design challenge, with varying size, cost, and complexity. This dissertation presents a self-oscillating resonant gate...

  11. Cultures of High-frequency Trading

    DEFF Research Database (Denmark)

    Lange, Ann-Christina; Lenglet, Marc; Seyfert, Robert

    2016-01-01

    As part of ongoing work to lay a foundation for social studies of high-frequency trading (HFT), this paper introduces the culture(s) of HFT as a sociological problem relating to knowledge and practice. HFT is often discussed as a purely technological development, where all that matters is the speed...... of allocating, processing and transmitting data. Indeed, the speed at which trades are executed and data transmitted is accelerating, and it is fair to say that algorithms are now the primary interacting agents operating in the financial markets. However, we contend that HFT is first and foremost a cultural...

  12. The LASI high-frequency ellipticity system

    Energy Technology Data Exchange (ETDEWEB)

    Sternberg, B.K.; Poulton, M.M. [Univ. of Arizona, Tucson, AZ (United States)

    1995-10-01

    A high-frequency, high-resolution, electromagnetic (EM) imaging system has been developed for environmental geophysics surveys. Some key features of this system include: (1) rapid surveying to allow dense spatial sampling over a large area, (2) high-accuracy measurements which are used to produce a high-resolution image of the subsurface, (3) measurements which have excellent signal-to-noise ratio over a wide bandwidth (31 kHz to 32 MHz), (4) large-scale physical modeling to produce accurate theoretical responses over targets of interest in environmental geophysics surveys, (5) rapid neural network interpretation at the field site, and (6) visualization of complex structures during the survey.

  13. Vertical Nanowire High-Frequency Transistors

    OpenAIRE

    Johansson, Sofia

    2014-01-01

    This thesis explores a novel transistor technology based on vertical InAs nanowires, which could be considered both for low-power high-frequency analog applications and for replacing Si CMOS in the continued scaling of digital electronics. The potential of this device - the vertical InAs nanowire MOSFET – lies in the combination of the outstanding transport properties of InAs and the improved electrostatic control of the gate-all-around geometry. Three generations of the vertical InAs nanowir...

  14. Vertical Nanowire High-Frequency Transistors

    OpenAIRE

    Johansson, Sofia

    2014-01-01

    This thesis explores a novel transistor technology based on vertical InAs nanowires, which could be considered both for low-power high-frequency analog applications and for replacing Si CMOS in the continued scaling of digital electronics. The potential of this device - the vertical InAs nanowire MOSFET – lies in the combination of the outstanding transport properties of InAs and the improved electrostatic control of the gate-all-around geometry. Three generations of the vertical InAs nano...

  15. Effects of extreme obliquity variations on the habitability of exoplanets.

    Science.gov (United States)

    Armstrong, J C; Barnes, R; Domagal-Goldman, S; Breiner, J; Quinn, T R; Meadows, V S

    2014-04-01

    We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. We show that large-amplitude, high-frequency obliquity oscillations on Earth-like exoplanets can suppress the ice-albedo feedback, increasing the outer edge of the habitable zone. We restricted our exploration to hypothetical systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 larger planets. We verified that these systems are stable for 10(8) years with N-body simulations and calculated the obliquity variations induced by the orbital evolution of the Earth-mass planet and a torque from the host star. We ran a simplified energy balance model on the terrestrial planet to assess surface temperature and ice coverage on the planet's surface, and we calculated differences in the outer edge of the habitable zone for planets with rapid obliquity variations. For each hypothetical system, we calculated the outer edge of habitability for two conditions: (1) the full evolution of the planetary spin and orbit and (2) the eccentricity and obliquity fixed at their average values. We recovered previous results that higher values of fixed obliquity and eccentricity expand the habitable zone, but we also found that obliquity oscillations further expand habitable orbits in all cases. Terrestrial planets near the outer edge of the habitable zone may be more likely to support life in systems that induce rapid obliquity oscillations as opposed to fixed-spin planets. Such planets may be the easiest to directly characterize with space-borne telescopes.

  16. Effects of Extreme Obliquity Variations on the Habitability of Exoplanets

    Science.gov (United States)

    Armstrong, J. C.; Barnes, R.; Domagal-Goldman, S.; Breiner, J.; Quinn, T. R.; Meadows, V. S.

    2014-01-01

    We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. We show that large-amplitude, high-frequency obliquity oscillations on Earth-like exoplanets can suppress the ice-albedo feedback, increasing the outer edge of the habitable zone. We restricted our exploration to hypothetical systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 larger planets. We verified that these systems are stable for 108 years with N-body simulations and calculated the obliquity variations induced by the orbital evolution of the Earth-mass planet and a torque from the host star. We ran a simplified energy balance model on the terrestrial planet to assess surface temperature and ice coverage on the planet's surface, and we calculated differences in the outer edge of the habitable zone for planets with rapid obliquity variations. For each hypothetical system, we calculated the outer edge of habitability for two conditions: (1) the full evolution of the planetary spin and orbit and (2) the eccentricity and obliquity fixed at their average values. We recovered previous results that higher values of fixed obliquity and eccentricity expand the habitable zone, but we also found that obliquity oscillations further expand habitable orbits in all cases. Terrestrial planets near the outer edge of the habitable zone may be more likely to support life in systems that induce rapid obliquity oscillations as opposed to fixed-spin planets. Such planets may be the easiest to directly characterize with space-borne telescopes.

  17. Climates of Oblique Exoplanets

    Science.gov (United States)

    Dobrovolskis, A. R.

    2008-12-01

    A previous paper (Dobrovolskis 2007; Icarus 192, 1-23) showed that eccentricity can have profound effects on the climate, habitability, and detectability of extrasolar planets. This complementary study shows that obliquity can have comparable effects. The known exoplanets exhibit a wide range of orbital eccentricities, but those within several million km of their suns are generally in near-circular orbits. This fact is widely attributed to the dissipation of tides in the planets, which is particularly effective for solid/liquid bodies like "Super-Earths". Along with friction between a solid mantle and a liquid core, tides also are expected to despin a planet until it is captured in the synchronous resonance, so that its rotation period is identical to its orbital period. The canonical example of synchronous spin is the way that our Moon always keeps nearly the same hemisphere facing the Earth. Tides also tend to reduce the planet's obliquity (the angle between its spin and orbital angular velocities). However, orbit precession can cause the rotation to become locked in a "Cassini state", where it retains a nearly constant non-zero obliquity. For example, our Moon maintains an obliquity of about 6.7° with respect to its orbit about the Earth. For comparison, stable Cassini states can exist for practically any obliquity up to 180° for planets of binary stars, or in multi-planet systems with high mutual inclinations, such as are produced by scattering or by the Kozai mechanism. This work considers planets in synchronous rotation with circular orbits. For obliquities greater than 90°, the ground track of the sub-solar point wraps around all longitudes on the surface of such a planet. For smaller obliquities, the sub-solar track takes the figure-8 shape of an analemma. This can be visualized as the intersection of the planet's spherical surface with a right circular cylinder, parallel to the spin axis and tangent to the equator from the inside. The excursion of the

  18. Oblique Axis Body Fracture

    DEFF Research Database (Denmark)

    Takai, Hirokazu; Konstantinidis, Lukas; Schmal, Hagen

    2016-01-01

    Purpose. Anderson type III odontoid fractures have traditionally been considered stable and treated conservatively. However, unstable cases with unfavorable results following conservative treatment have been reported. Methods. We present the cases of two patients who sustained minimally displaced...... Anderson type III fractures with a characteristic fracture pattern that we refer to as "oblique type axis body fracture." Results. The female patients aged 90 and 72 years, respectively, were both diagnosed with minimally displaced Anderson type III fractures. Both fractures had a characteristic "oblique...... type" fracture pattern. The first patient was treated conservatively with cervical spine immobilization in a semirigid collar. However, gross displacement was noted at the 6-week follow-up visit. The second patient was therefore treated operatively by C1-C3/4 posterior fusion and the course...

  19. Oblique Axis Body Fracture

    DEFF Research Database (Denmark)

    Takai, Hirokazu; Konstantinidis, Lukas; Schmal, Hagen;

    2016-01-01

    was uneventful. Conclusions. Oblique type axis body fractures resemble a highly unstable subtype of Anderson type III fractures with the potential of severe secondary deformity following conservative treatment, irrespective of initial grade of displacement. The authors therefore warrant a high index of suspicion......Purpose. Anderson type III odontoid fractures have traditionally been considered stable and treated conservatively. However, unstable cases with unfavorable results following conservative treatment have been reported. Methods. We present the cases of two patients who sustained minimally displaced...

  20. Laser and high-frequency cauthery gingivectomy in nonperiodontal indications: assessment and comparison of techniques

    Science.gov (United States)

    Bartak, Petr; Smucler, Roman

    2003-06-01

    The authors have verified the efficiency and safety of laser and high-frequency gingivectomy in non-periodontal indications. Within a prospective, non-selective study, they treated and monitored 357 dental areas in 139 teeth.Out of the total number, 248 areas were treated wtih a diode laser, 980nm; 109 areas with high-frequency electrocautery. The following parameters were monitored: a) regeneration of the marginal gingiva; b) generation of iatrogenic recessions or periodontal pockets; c) bleeding from gingival sulcus during probing; d) changes in tooth vitality; e) patient's subjective evaluation. The authors identified a high degree of safety in both laser and high-frequency gingivectomy, with no significant difference between these two methods. Laser gingivectomy appears to have a wider indication range, while high-frequency gingivectomy requires lower financial expenses.

  1. The obliquity of Enceladus

    CERN Document Server

    Baland, Rose-Marie; Van Hoolst, Tim

    2015-01-01

    The extraordinary activity at Enceladus' warm south pole indicates the presence of an internal global or local reservoir of liquid water beneath the surface. While Tyler (2009, 2011) has suggested that the geological activity and the large heat flow of Enceladus could result from tidal heating triggered by a large obliquity of at least 0.05{\\deg}-0.1{\\deg}, theoretical models of the Cassini state predict the obliquity to be two to three orders of magnitude smaller for an entirely solid and rigid Enceladus. We investigate the influence of an internal subsurface ocean and of tidal deformations of the solid layers on the obliquity of Enceladus. Our Cassini state model takes into account the external torque exerted by Saturn on each layer of the satellite and the internal gravitational and pressure torques induced by the presence of the liquid layer. As a new feature, our model also includes additional torques that arise because of the periodic tides experienced by the satellite. We find that the upper limit for ...

  2. Parametric nanomechanical amplification at very high frequency.

    Science.gov (United States)

    Karabalin, R B; Feng, X L; Roukes, M L

    2009-09-01

    Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS). Compound mechanical nanostructures patterned by multilayer, top-down nanofabrication are read out by a novel scheme that parametrically modulates longitudinal stress in doubly clamped beam NEMS resonators. Parametric pumping and signal amplification are demonstrated for VHF resonators up to approximately 130 MHz and provide useful enhancement of both resonance signal amplitude and quality factor. We find that Joule heating and reduced thermal conductance in these nanostructures ultimately impose an upper limit to device performance. We develop a theoretical model to account for both the parametric response and nonequilibrium thermal transport in these composite nanostructures. The results closely conform to our experimental observations, elucidate the frequency and threshold-voltage scaling in parametric VHF NEMS resonators and sensors, and establish the ultimate sensitivity limits of this approach.

  3. Solar coronal observations at high frequencies

    CERN Document Server

    Katsiyannis, A C; Phillips, K J H; Williams, D R; Keenan, F P

    2001-01-01

    The Solar Eclipse Coronal Imaging System (SECIS) is a simple and extremely fast, high-resolution imaging instrument designed for studies of the solar corona. Light from the corona (during, for example, a total solar eclipse) is reflected off a heliostat and passes via a Schmidt-Cassegrain telescope and beam splitter to two CCD cameras capable of imaging at 60 frames a second. The cameras are attached via SCSI connections to a purpose-built PC that acts as the data acquisition and storage system. Each optical channel has a different filter allowing observations of the same events in both white light and in the green line (Fe XIV at 5303 A). Wavelet analysis of the stabilized images has revealed high frequency oscillations which may make a significant contribution on the coronal heating process. In this presentation we give an outline of the instrument and its future development.

  4. High-frequency micromechanical columnar resonators

    Directory of Open Access Journals (Sweden)

    Jenny Kehrbusch, Elena A Ilin, Peter Bozek, Bernhard Radzio and Egbert Oesterschulze

    2009-01-01

    Full Text Available High-frequency silicon columnar microresonators are fabricated using a simple but effective technological scheme. An optimized fabrication scheme was invented to obtain mechanically protected microcolumns with lateral dimensions controlled on a scale of at least 1 μm. In this paper, we investigate the influence of the environmental conditions on the mechanical resonator properties. At ambient conditions, we observed a frequency stability δf/f of less than 10−6 during 5 h of operation at almost constant temperature. However, varying the temperature shifts the frequency by approximately −173 Hz °C− 1. In accordance with a viscous damping model of the ambient gas, we perceived that the quality factor of the first flexural mode decreased with the inverse of the square root of pressure. However, in the low-pressure regime, a linear dependence was observed. We also investigated the influence of the type of the immersing gas on the resonant frequency.

  5. High-frequency lunar teleseismic events

    Science.gov (United States)

    Nakamura, Y.; Dorman, J.; Duennebier, F.; Ewing, M.; Lammlein, D.; Latham, G.

    1974-01-01

    A small number of seismic signals, including some of the strongest observed to date, have been identified as representing a fourth principal category of natural lunar seismic events with characteristics distinct from those produced by normal meteoroid impacts, deep moonquakes, and thermal moonquakes. These signals are much richer in high frequencies than other events observed at comparable distances, and display relatively impulsive P- and S-wave beginnings, indicating negligible seismic-wave scattering near the source. Source depths of these events may range between 0 and perhaps 300 km. These and other characteristics could represent either (1) meteoroids impacting upon outcrops of competent lunar crystal rock, (2) rare impacting objects that penetrate to competent rock below a scattering zone, or (3) shallow tectonic moonquakes.

  6. Plasma effects in high frequency radiative transfer

    Science.gov (United States)

    Alonso, C. T.

    1981-02-01

    A survey of collective plasma processes which can affect the transfer of high frequency radiation in a hot dense plasma is given. For pedagogical reasons plasma processes are examined by relating them to a particular reference plasma which consists of fully ionized carbon at a temperature kT = 1 KeV (ten million degrees Kelvin) and an electron density N = 3 x 10 to the 23rd power/cu cm, (which corresponds to a mass density rho = 1 gm/cu cm) and an ion density N sub i = 5 x 10 to the 22nd power/cu cm. The transport of photons, ranging from 1 eV to 1 KeV in energy, in such plasmas is considered. Such photons are to be used as diagnostic probes of hot dense laboratory plasmas.

  7. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy

    NARCIS (Netherlands)

    Zweiphenning, W. J E M; van 't Klooster, M. A.; van Diessen, E.; van Klink, N. E C; Huiskamp, G. J M|info:eu-repo/dai/nl/074463640; Gebbink, T. A.; Leijten, F. S S|info:eu-repo/dai/nl/152243054; Gosselaar, P. H.|info:eu-repo/dai/nl/304813990; Otte, W. M.|info:eu-repo/dai/nl/168455706; Stam, C. J.; Braun, K. P J|info:eu-repo/dai/nl/207237239; Zijlmans, G. J M|info:eu-repo/dai/nl/304819581

    2016-01-01

    OBJECTIVE: High frequency oscillations (HFOs; > 80 Hz), especially fast ripples (FRs, 250-500 Hz), are novel biomarkers for epileptogenic tissue. The pathophysiology suggests enhanced functional connectivity within FR generating tissue. Our aim was to determine the relation between brain areas

  8. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy

    Directory of Open Access Journals (Sweden)

    W.J.E.M. Zweiphenning

    2016-01-01

    Significance: ‘Baseline’ high-frequency network parameters might help intra-operative recognition of epileptogenic tissue without the need for waiting for events. These findings can increase our understanding of the ‘architecture’ of epileptogenic networks and help unravel the pathophysiology of HFOs.

  9. High frequency strain measurements with fiber Bragg grating sensors

    Science.gov (United States)

    Koch, J.; Angelmahr, M.; Schade, W.

    2015-05-01

    In recent years fiber Bragg grating sensors gained interest in structural health monitoring and concepts for smart structures. They are small, lightweight, and immune to electromagnetic interference. Using multiplexing techniques, several sensors can be addressed by a single fiber. Therefore, well-established structures and materials in industrial applications can be easily equipped with fiber optical sensors with marginal influence on their mechanical properties. In return, critical components can be monitored in real-time, leading to reduced maintenance intervals and a great reduction of costs. Beside of generally condition monitoring, the localization of failures in a structure is a desired feature of the condition monitoring system. Detecting the acoustic emission of a sudden event, its place of origin can be determined by analyzing the delay time of distributed sensor signals. To achieve high localization accuracies for the detection of cracks, breaks, and impacts high sampling rates combined with the simultaneous interrogation of several fiber Bragg grating sensors are required. In this article a fiber Bragg grating interrogator for high frequency measurements up to the megahertz range is presented. The interrogator is based on a passive wavelength to intensity conversion applying arrayed waveguide gratings. Light power fluctuations are suppressed by a differential data evaluation, leading to a reduced signal-to-noise ratio and a low strain detection limit. The measurement system is used to detect, inter alia, wire breaks in steel wire ropes for dockside cranes.

  10. High-frequency graphene voltage amplifier.

    Science.gov (United States)

    Han, Shu-Jen; Jenkins, Keith A; Valdes Garcia, Alberto; Franklin, Aaron D; Bol, Ageeth A; Haensch, Wilfried

    2011-09-14

    While graphene transistors have proven capable of delivering gigahertz-range cutoff frequencies, applying the devices to RF circuits has been largely hindered by the lack of current saturation in the zero band gap graphene. Herein, the first high-frequency voltage amplifier is demonstrated using large-area chemical vapor deposition grown graphene. The graphene field-effect transistor (GFET) has a 6-finger gate design with gate length of 500 nm. The graphene common-source amplifier exhibits ∼5 dB low frequency gain with the 3 dB bandwidth greater than 6 GHz. This first AC voltage gain demonstration of a GFET is attributed to the clear current saturation in the device, which is enabled by an ultrathin gate dielectric (4 nm HfO(2)) of the embedded gate structures. The device also shows extrinsic transconductance of 1.2 mS/μm at 1 V drain bias, the highest for graphene FETs using large-scale graphene reported to date.

  11. High frequency band crossings in ^168Lu.

    Science.gov (United States)

    Roux, D. G.; Li, Y.; Ma, W. C.; Amro, H.; Thompson, J.; Winger, J.; Hagemann, G.; Herskind, B.; Jensen, D.; Sletten, G.; Wilson, J.; Fallon, P.; Diamond, R.; Goergen, A.; Machiavelli, A.; Ward, D.; Hübel, H.; Domscheit, J.

    2003-10-01

    High spin states in ^168Lu were populated using the ^123Sb(^48Ca,3n) reaction at 203 MeV. The beam was provided by the 88" cyclotron at LBNL, and coincident gamma rays were detected with the Gammasphere spectrometer array. An analysis of the data which had been sorted into three- and four- dimensional histograms confirmed the four previously known (J.H.Ha et al. J. Phys. Soc. Japan 71 (2002) 1663-1671) pairs of signature partner bands and extended them to considerably higher spins (in one case up to a tentative 50 hbar). In addition, a new pair of signature partners, as well as a new doubly decoupled band were found. On the basis of the present data, the configuration of one of the known bands, previously assigned π d_3/2 øtimes ν i_13/2 was reassigned as π d_5/2 øtimes ν i_13/2. High frequency band crossings, beyond the first ν i_13/2 alignment, were observed for the first time. These results will be discussed with reference to Cranking Shell Model calculations.

  12. Plant Responses to High Frequency Electromagnetic Fields

    Directory of Open Access Journals (Sweden)

    Alain Vian

    2016-01-01

    Full Text Available High frequency nonionizing electromagnetic fields (HF-EMF that are increasingly present in the environment constitute a genuine environmental stimulus able to evoke specific responses in plants that share many similarities with those observed after a stressful treatment. Plants constitute an outstanding model to study such interactions since their architecture (high surface area to volume ratio optimizes their interaction with the environment. In the present review, after identifying the main exposure devices (transverse and gigahertz electromagnetic cells, wave guide, and mode stirred reverberating chamber and general physics laws that govern EMF interactions with plants, we illustrate some of the observed responses after exposure to HF-EMF at the cellular, molecular, and whole plant scale. Indeed, numerous metabolic activities (reactive oxygen species metabolism, α- and β-amylase, Krebs cycle, pentose phosphate pathway, chlorophyll content, terpene emission, etc. are modified, gene expression altered (calmodulin, calcium-dependent protein kinase, and proteinase inhibitor, and growth reduced (stem elongation and dry weight after low power (i.e., nonthermal HF-EMF exposure. These changes occur not only in the tissues directly exposed but also systemically in distant tissues. While the long-term impact of these metabolic changes remains largely unknown, we propose to consider nonionizing HF-EMF radiation as a noninjurious, genuine environmental factor that readily evokes changes in plant metabolism.

  13. Ionospheric heating with oblique HF waves

    Science.gov (United States)

    Field, Edward C., Jr.; Bloom, Ron M.

    1990-10-01

    Calculations of ionospheric electron density perturbations and ground-level signal changes produce by intense oblique high frequency (HF) transmitters are presented. This analysis considers radio field focusing at caustics, the consequent joule-heating of the surrounding plasma, heat conduction, diffusion, and recombination processes: these being the effects of a powerful oblique 'modifying' wave. It neglects whatever plasma instabilities might occur. Then effects on a secondary 'test' wave that is propagated along the same path as the first are investigated. Calculations predict ground-level field-strength reductions of several dB in the test wave for modifying waves having ERP in the 85 to 90 dBW range. These field-strength changes are similar in sign, magnitude, and location to ones measured in Soviet experiments. The results are sensitive to the model ionosphere assumed, so future experiments should employ the widest possible range of frequencies and propagation conditions. An effective power of 90 dBW seems to be a sort of threshold that, if exceeded, results in substantial rather than small signal changes. The conclusions are based solely on joule-heating and subsequent defocusing of waves passing through caustic regions.

  14. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakage...... inductance and proposes an accurate prediction methodology. High frequency leakage inductances in several interleaved winding configurations are also discussed. Interleaved winding configurations actually give a smaller degree of reduction of leakage induction at high frequency. Finite Element Analysis (FEA...

  15. Where is the value in high frequency trading?

    OpenAIRE

    Álvaro Cartea; José Penalva

    2011-01-01

    We analyze the impact of high frequency trading in financial markets based on a model with three types of traders: liquidity traders, market makers, and high frequency traders. Our four main findings are: i) The price impact of the liquidity trades is higher in the presence of the high frequency trader and is increasing with the size of the trade. In particular, we show that the high frequency trader reduces (increases) the prices that liquidity traders receive when selling (buying) their equ...

  16. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy.

    Science.gov (United States)

    Zweiphenning, W J E M; van 't Klooster, M A; van Diessen, E; van Klink, N E C; Huiskamp, G J M; Gebbink, T A; Leijten, F S S; Gosselaar, P H; Otte, W M; Stam, C J; Braun, K P J; Zijlmans, G J M

    2016-01-01

    High frequency oscillations (HFOs; > 80 Hz), especially fast ripples (FRs, 250-500 Hz), are novel biomarkers for epileptogenic tissue. The pathophysiology suggests enhanced functional connectivity within FR generating tissue. Our aim was to determine the relation between brain areas showing FRs and 'baseline' functional connectivity within EEG networks, especially in the high frequency bands. We marked FRs, ripples (80-250 Hz) and spikes in the electrocorticogram of 14 patients with refractory temporal lobe epilepsy. We assessed 'baseline' functional connectivity in epochs free of epileptiform events within these recordings, using the phase lag index. We computed the Eigenvector Centrality (EC) per channel in the FR and gamma band network. We compared EC between channels that did or did not show events at other moments in time. FR-band EC was higher in channels with than without spikes. Gamma-band EC was lower in channels with ripples and FRs. We confirmed previous findings of functional isolation in the gamma-band and found a first proof of functional integration in the FR-band network of channels covering presumed epileptogenic tissue. 'Baseline' high-frequency network parameters might help intra-operative recognition of epileptogenic tissue without the need for waiting for events. These findings can increase our understanding of the 'architecture' of epileptogenic networks and help unravel the pathophysiology of HFOs.

  17. High-Frequency Axial Fatigue Test Procedures for Spectrum Loading

    Science.gov (United States)

    2016-07-20

    REPORT NO: NAWCADPAX/TIM-2016/49 HIGH - FREQUENCY AXIAL FATIGUE TEST PROCEEDURES FOR SPECTRUM LOADING by David T. Rusk, AIR...OF THE NAVY NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION PATUXENT RIVER, MARYLAND NAWCADPAX/TIM-2016/49 20 July 2016 HIGH - FREQUENCY AXIAL...Technical Information Memorandum 3. DATES COVERED 4. TITLE AND SUBTITLE High - Frequency Axial Fatigue Test Procedures for Spectrum Loading

  18. Anomalous waiting times in high-frequency financial data

    CERN Document Server

    Scalas, E; Luckock, H; Mainardi, F; Mantelli, M; Raberto, M; Scalas, Enrico; Gorenflo, Rudolf; Luckock, Hugh; Mainardi, Francesco; Mantelli, Maurizio; Raberto, Marco

    2004-01-01

    In high-frequency financial data not only returns, but also waiting times between consecutive trades are random variables. Therefore, it is possible to apply continuous-time random walks (CTRWs) as phenomenological models of the high-frequency price dynamics. An empirical analysis performed on the 30 DJIA stocks shows that the waiting-time survival probability for high-frequency data is non-exponential. This fact imposes constraints on agent-based models of financial markets.

  19. Wideband high frequency (HF) skywave channel parameters from narrowband measurements

    Science.gov (United States)

    Hausman, Cynthia L.; Uffelman, Donald R.; Walton, Thomas L.

    The HF wideband channel allow the use of spread-spectrum techniques to provide covert communications with low probability of intercept (LPI) and antijam protection. The objective of this work is to determine the extent to which oblique narrowband channel measurements can be used to infer effects in the wideband skywave channel. If oblique narrowband channel measurements can be used as a basis for developing wideband channel models, a large number of existing narrowband measurements can be made available for this task.

  20. Oblique dust density waves

    Science.gov (United States)

    Piel, Alexander; Arp, Oliver; Menzel, Kristoffer; Klindworth, Markus

    2007-11-01

    We report on experimental observations of dust density waves in a complex (dusty) plasma under microgravity. The plasma is produced in a radio-frequency parallel-plate discharge (argon, p=15Pa, U=65Vpp). Different sizes of dust particles were used (3.4 μm and 6.4μm diameter). The low-frequency (f 11Hz) dust density waves are naturally unstable modes, which are driven by the ion flow in the plasma. Surprisingly, the wave propagation direction is aligned with the ion flow direction in the bulk plasma but becomes oblique at the boundary of the dust cloud with an inclination of 60^o with respect to the plasma boundary. The experimental results are compared with a kinetic model in the electrostatic approximation [1] and a fluid model [2]. Moreover, the role of dust surface waves is discussed. [1] M. Rosenberg, J. Vac. Sci. Technol. A 14, 631 (1996) [2] A. Piel et al, Phys. Rev. Lett. 97, 205009 (2006)

  1. Catchment Very-High Frequency Hydrochemistry: the Critex Chemical House

    Science.gov (United States)

    Floury, P.; Gaillardet, J.; Tallec, G.; Blanchouin, A.; Ansart, P.

    2015-12-01

    Exploring the variations of river quality at very high frequency is still a big challenge that has fundamental implications both for understanding catchment ecosystems and for water quality monitoring. Within the French Critical Zone program CRITEX, we have proposed to develop a prototype called "Chemical House", applying the "lab on field" concept to one of the stream of the Orgeval Critical Zone Observatory. The Orgeval catchment (45 km2) is part of the Critical Zone RBV ("Réseau des bassins versants") network. It is a typical temperate agricultural catchment that has been intensively monitored for the last 50 years for hydrology and nutrient chemistry. Agricultural inputs and land use are also finely monitored making Orgeval an ideal basin to test the response of the Critical Zone to agricultural forcing. Geology consists of a typical sedimentary basin of Cenozoic age with horizontal layers of limestones, silcrete and marls, covered by a thin loamy layer. Two main aquifers are present within the catchment: the Brie and the Champigny aquifers. Mean runoff is 780 mm/yr. The Chemical House is a fully automated lab and installed directly along the river, which performs measurement of all major dissolved elements such as Na, Cl, Mg, Ca, NO3, SO4 and K every half hour. It also records all physical parameters (Temperature, pH, conductivity, O2 dissolved, Turbidity) of the water every minute. Orgeval Chemical House started to measure river chemistry on June 12, 2015 and has successfully now recorded several months of data. We will present the architecture of the Chemical House and the first reproducibility and accuracy tests made during the summer drought 2015 period. Preliminary results show that the chemical house is recoding significant nychtemeral (day/night) cycles for each element. We also observe that each element has its own behaviour along a day. First results open great prospects.

  2. Nonlinear evolution of oblique whistler waves in radiation belts

    Science.gov (United States)

    Sharma, R. P.; Nandal, P.; Yadav, N.; Sharma, Swati

    2017-02-01

    Magnetic power spectrum and formation of coherent structures have been investigated in the present work applicable to Van Allen radiation belt. The nonlinear interaction of high frequency oblique whistler wave and low frequency magnetosonic wave has been investigated. Simulation was performed of the coupled equation of these two waves. The nonlinear interaction of these waves leads to the formation of the localized structures. These resulting localized structures are of complex nature. The associated magnetic power spectrum has also been studied. Dispersive nonlinear processes account for the high frequency part of the spectrum. The resulting magnetic power spectrum shows a scaling of k^{ - 4.5}. The energy transfer process from injection scales to smaller scales is explained by the results.

  3. Influence of Smoking on Ultra-High-Frequency Auditory Sensitivity.

    Science.gov (United States)

    Prabhu, Prashanth; Varma, Gowtham; Dutta, Kristi Kaveri; Kumar, Prajwal; Goyal, Swati

    2017-04-01

    In this study, an attempt was made to determine the effect of smoking on ultra-high-frequency auditory sensitivity. The study also attempted to determine the relationship between the nature of smoking and ultra-high-frequency otoacoustic emissions (OAEs) and thresholds. The study sample included 25 smokers and 25 non-smokers. A detailed history regarding their smoking habits was collected. High-frequency audiometric thresholds and amplitudes of high-frequency distortion-product OAEs were analyzed for both ears from all participants. The results showed that the ultra-high-frequency thresholds were elevated and that there was reduction in the amplitudes of ultra-high-frequency OAEs in smokers. There was an increased risk of auditory damage with chronic smoking. The study results highlight the application of ultra-high-frequency OAEs and ultra-high-frequency audiometry for the early detection of auditory impairment. However, similar studies should be conducted on a larger population for better generalization of the results.

  4. Special Information on High-Frequency Radar. Part 15

    Science.gov (United States)

    1971-06-01

    NRL Memorandum Report 2265 f Special Information on High-Frequency Radar Part XV J. M. HEADRICK, W. C. HEADRICK, J. M. HUDNALL AND J. F. THOMASON...20390 3. REPORT TITLE SPECIAL INFORMATION ON HIGH-FREQUENCY RADAR, PART XV (U) 4. DESCRIPTIVE NOTES(Type of report and inclhsive dates) This is a final

  5. High frequency chest compression effects heart rate variability.

    Science.gov (United States)

    Lee, Jongwon; Lee, Yong W; Warwick, Warren J

    2007-01-01

    High frequency chest compression (HFCC) supplies a sequence of air pulses through a jacket worn by a patient to remove excessive mucus for the treatment or prevention of lung disease patients. The air pulses produced from the pulse generator propagates over the thorax delivering the vibration and compression energy. A number of studies have demonstrated that the HFCC system increases the ability to clear mucus and improves lung function. Few studies have examined the change in instantaneous heart rate (iHR) and heart rate variability (HRV) during the HFCC therapy. The purpose of this study is to measure the change of HRV with four experimental protocols: (a) without HFCC, (b) during Inflated, (c)HFCC at 6Hz, and (d) HFCC at 21Hz. The nonlinearity and regularity of HRV was assessed by approximate entropy (ApEn), a method used to quantify the complexities and randomness. To compute the ApEn, we sectioned with a total of eight epochs and displayed the ApEn over the each epoch. Our results show significant differences in the both the iHR and HRV between the experimental protocols. The iHR was elevated at both the (c) 6Hz and (d) 21Hz condition from without HFCC (10%, 16%, respectively). We also found that the HFCC system tends to increase the HRV. Our study suggests that monitoring iHR and HRV are very important physiological indexes during HFCC therapy.

  6. High frequency guided wave propagation in monocrystalline silicon wafers

    Science.gov (United States)

    Pizzolato, Marco; Masserey, Bernard; Robyr, Jean-Luc; Fromme, Paul

    2017-04-01

    Monocrystalline silicon wafers are widely used in the photovoltaic industry for solar panels with high conversion efficiency. The cutting process can introduce micro-cracks in the thin wafers and lead to varying thickness. High frequency guided ultrasonic waves are considered for the structural monitoring of the wafers. The anisotropy of the monocrystalline silicon leads to variations of the wave characteristics, depending on the propagation direction relative to the crystal orientation. Full three-dimensional Finite Element simulations of the guided wave propagation were conducted to visualize and quantify these effects for a line source. The phase velocity (slowness) and skew angle of the two fundamental Lamb wave modes (first anti-symmetric mode A0 and first symmetric mode S0) for varying propagation directions relative to the crystal orientation were measured experimentally. Selective mode excitation was achieved using a contact piezoelectric transducer with a custom-made wedge and holder to achieve a controlled contact pressure. The out-of-plane component of the guided wave propagation was measured using a noncontact laser interferometer. Good agreement was found with the simulation results and theoretical predictions based on nominal material properties of the silicon wafer.

  7. Establish of the orthotopic human pancreatic cancer model in mice and high frequency probe of endoscopy ultrasonographic monitoring%原位注射法建立人胰腺癌SW1990裸鼠种植瘤模型及高频内镜超声探头对其的监测

    Institute of Scientific and Technical Information of China (English)

    马建霞; 司佩任; 吴洪玉; 王洛伟; 潘雪; 高军; 李兆申; 金震东

    2011-01-01

    Objective To establish the orthotopic human pancreatic cancer model in mice and study the method to detect the tumor growth. Methods Human pancreatic cancer cell lines SW1990 in logarithmic phase was made into cell suspension and in situ injected into the envelope of pancreatic tail of BALB/c nude mice. High-frequency endoscopy ultrasound was used to observe the growth of tumor mass and its imaging characteristics were studied. Results 20 nude mice were successfully implanted, and 1 died 25 h after implantation. 14 days after implantation, the tumor of pancreatic cancer on EUS was (8.09 ± 2.61) mm3, the tumor appeared as homogeneous hypoechoic mass with clear boundary, and envelope as well as sound halo was present, and the shape was regular; there was low speed circular vasculature signal in around 30% of tumor.The tumor size increased to (12.40 ± 3.51)mm3, and the shape of 70% tumor was irregular, and some appeared as lobulated, and the tumor appeared as heterogeneous hypoechoic mass, no necrosis or liquefaction was found 28 days after implantation. There was low speed circular vasculature signal in around 70% tumors.Conclusions The orthotopic pancreatic cancer model in nude mouse can be established by in situ injection and this method is relatively ideal because it is simple and effective. The high frequency probe of endoscopic ultrasonograph is a reliable method for monitoring implanted pancreatic cancer.%目的 建立裸小鼠人胰腺癌原位种植瘤模型,探索监测种植瘤生长的方法.方法 将对数生长期的人胰腺癌细胞株SW1990制备成细胞悬液,原位注射于Balb/c-nu裸小鼠胰腺尾部包膜下,利用高频内镜超声(EUS)探头体表观察肿瘤结节的生长及声像图像.结果 20只裸小鼠均接种成功,1只裸鼠于接种后25 d时死亡.接种后14 d,EUS检查的瘤体大小为(8.09±2.61)mm3,肿瘤结节呈均质低回声,边界清楚,周边有包膜及声晕,形态规则,30%的肿瘤结节周边可见低速环

  8. Extended high frequency audiometry in secretory otitis media.

    Science.gov (United States)

    Sharma, Deepika; Munjal, Sanjay K; Panda, Naresh K

    2012-06-01

    The objective of the present study was to determine the status of extended high frequencies in subjects with secretory otitis media. The study evaluated 30 ears of 20 subjects with secretory otitis media in the age group of 15-30 years. This data was compared with 20 ears of 10 volunteers of the same age group with clinically normal hearing. Pure tone air conduction thresholds were analyzed in three frequency groups: low frequency (LF: 0.25, 0.5, and 1 kHz), high frequency (HF: 2, 4, and 8 kHz) and extended high frequency (EHF: 10, 12, and 16 kHz). The results showed elevated extended high frequency thresholds (EHFG) as compared to control group and comparatively better thresholds at high frequencies(HFG)s as compared to low (LFG)and extended high frequencies(EHFG) in the study group. This validates the importance of including an extended high frequency audiometry in the test battery of patients with secretory otitis media.

  9. High-frequency energy in singing and speech

    Science.gov (United States)

    Monson, Brian Bruce

    While human speech and the human voice generate acoustical energy up to (and beyond) 20 kHz, the energy above approximately 5 kHz has been largely neglected. Evidence is accruing that this high-frequency energy contains perceptual information relevant to speech and voice, including percepts of quality, localization, and intelligibility. The present research was an initial step in the long-range goal of characterizing high-frequency energy in singing voice and speech, with particular regard for its perceptual role and its potential for modification during voice and speech production. In this study, a database of high-fidelity recordings of talkers was created and used for a broad acoustical analysis and general characterization of high-frequency energy, as well as specific characterization of phoneme category, voice and speech intensity level, and mode of production (speech versus singing) by high-frequency energy content. Directionality of radiation of high-frequency energy from the mouth was also examined. The recordings were used for perceptual experiments wherein listeners were asked to discriminate between speech and voice samples that differed only in high-frequency energy content. Listeners were also subjected to gender discrimination tasks, mode-of-production discrimination tasks, and transcription tasks with samples of speech and singing that contained only high-frequency content. The combination of these experiments has revealed that (1) human listeners are able to detect very subtle level changes in high-frequency energy, and (2) human listeners are able to extract significant perceptual information from high-frequency energy.

  10. SINGLE PHASE HIGH FREQUENCY AC CONVERTER FOR INDUCTION HEATING APPLICATION

    Directory of Open Access Journals (Sweden)

    M.A INAYATHULLAAH,

    2010-12-01

    Full Text Available The proposed topology reduces the total harmonic distortion (THD of a high frequency AC/AC Converter well below the acceptable limit. This paper deals with a novel single phase AC/DC/AC soft switching utility frequency AC to high frequency AC converter. In this paper a single phase full bridge inverter with Vienna rectifier as front end is used instead of conventional diode bridge rectifier to provide continuous sinusoidal input current with nearly unity power factor at the source side with extremely low distortion.. This power converter is more suitable and acceptable for cost effective high frequency (HF consumer induction heating applications.

  11. Secular obliquity variations for Ceres

    Science.gov (United States)

    Bills, Bruce; Scott, Bryan R.; Nimmo, Francis

    2016-10-01

    We have constructed secular variation models for the orbit and spin poles of the asteroid (1) Ceres, and used them to examine how the obliquity, or angular separation between spin and orbit poles, varies over a time span of several million years. The current obliquity is 4.3 degrees, which means that there are some regions near the poles which do not receive any direct Sunlight. The Dawn mission has provided an improved estimate of the spin pole orientation, and of the low degree gravity field. That allows us to estimate the rate at which the spin pole precesses about the instantaneous orbit pole.The orbit of Ceres is secularly perturbed by the planets, with Jupiter's influence dominating. The current inclination of the orbit plane, relative to the ecliptic, is 10.6 degrees. However, it varies between 7.27 and 11.78 degrees, with dominant periods of 22.1 and 39.6 kyr. The spin pole precession rate parameter has a period of 205 kyr, with current uncertainty of 3%, dominated by uncertainty in the mean moment of inertia of Ceres.The obliquity varies, with a dominant period of 24.5 kyr, with maximum values near 26 degrees, and minimum values somewhat less than the present value. Ceres is currently near to a minimum of its secular obliquity variations.The near-surface thermal environment thus has at least 3 important time scales: diurnal (9.07 hours), annual (4.60 years), and obliquity cycle (24.5 kyr). The annual thermal wave likely only penetrates a few meters, but the much long thermal wave associated with the obliquity cycle has a skin depth larger by a factor of 70 or so, depending upon thermal properties in the subsurface.

  12. Investigating DOC export dynamics using high-frequency instream concentration measurements

    Science.gov (United States)

    Oosterwoud, Marieke; Keller, Toralf; Musolff, Andreas; Frei, Sven; Park, Ji-Hyung; Fleckenstein, Jan H.

    2014-05-01

    Being able to monitor DOC concentrations using in-situ high frequency measurements makes it possible to better understand concentration-discharge behavior under different hydrological conditions. We developed a UV-Vis probe setup for modified/adapted use under field conditions. The quasi mobile probe setup allows a more flexible probe deployment. New or existing monitoring sites can easily be equipped for quasi-continuous monitoring or measurements can be performed at changing locations, without the need for additional infrastructure. We were able to gather high frequency data on DOC dynamics for one year in two streams in the Harz mountains in Germany. It proved that obtaining accurate DOC concentrations from the UV-Vis probes required frequent maintenance and probe calibration. The advantage of the setup over standard monitoring protocols becomes evident when comparing net exports over a year. In addition to mass improved balance calculations the high-frequency measurements can reveal intricate hysteretic relationships between discharge and concentrations that can provide valuable insights into the hydrologic dynamics and mechanisms that govern the delivery of DOC to the receiving waters. Measurements with similar probes from two additional catchments in Southern Germany and South Korea will be used to illustrate different discharge-concentration relationships and what can be learned from them about the hydrologic mechanisms that control the dynamics of DOC export.

  13. High-Frequency Microwave Processing of Materials Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Conducts research on high-frequency microwave processing of materials using a highpower, continuous-wave (CW), 83-GHz, quasi-optical beam system for rapid,...

  14. Conditions of the Classical Transmission Line Equations at High Frequency

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    New transmission line equations are deduced applying Maxwell's equations in this paper. The conditions of the classical transmission line equations have been discussed, which is important to solve the EM problems in high frequency case.

  15. High Temperature, High Frequency Fuel Metering Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  16. Quantum inductance and high frequency oscillators in graphene nanoribbons.

    Science.gov (United States)

    Begliarbekov, Milan; Strauf, Stefan; Search, Christopher P

    2011-04-22

    Here we investigate high frequency AC transport through narrow graphene nanoribbons with top-gate potentials that form a localized quantum dot. We show that as a consequence of the finite dwell time of an electron inside the quantum dot (QD), the QD behaves like a classical inductor at sufficiently high frequencies ω ≥ GHz. When the geometric capacitance of the top-gate and the quantum capacitance of the nanoribbon are accounted for, the admittance of the device behaves like a classical serial RLC circuit with resonant frequencies ω ∼ 100-900 GHz and Q-factors greater than 10(6). These results indicate that graphene nanoribbons can serve as all-electronic ultra-high frequency oscillators and filters, thereby extending the reach of high frequency electronics into new domains.

  17. High frequency modeling for quantum-well laser diodes

    Institute of Scientific and Technical Information of China (English)

    GAO JianJun

    2009-01-01

    High frequency modeling of quantum-well (OW) laser diodes for optoelectronic integrated circuit (OEIC) design is discussed in this paper. Modeling of the intrinsic device and the extrinsic components is discussed by accounting for important physical effects at both de and high frequency. The concepts of equivalent circuits representing both intrinsic and extrinsic components in a QW laser diode are ana-lyzed to obtain a physics-based high frequency model. The model is based on the physical rate equa-tions, and is versatile in that it permits both small-and large-signal simulations to be performed. Sev-eral procedures of the high frequency model parameter extraction are also discussed. Emphasis here is placed on validating the model via a comparison of simulated results with measured data of the small-signal modulation response, obtained over a wide range of optical output powers.

  18. High frequency ultrasound with color Doppler in dermatology*

    Science.gov (United States)

    Barcaui, Elisa de Oliveira; Carvalho, Antonio Carlos Pires; Lopes, Flavia Paiva Proença Lobo; Piñeiro-Maceira, Juan; Barcaui, Carlos Baptista

    2016-01-01

    Ultrasonography is a method of imaging that classically is used in dermatology to study changes in the hypoderma, as nodules and infectious and inflammatory processes. The introduction of high frequency and resolution equipments enabled the observation of superficial structures, allowing differentiation between skin layers and providing details for the analysis of the skin and its appendages. This paper aims to review the basic principles of high frequency ultrasound and its applications in different areas of dermatology. PMID:27438191

  19. Basis of Ionospheric Modification by High-Frequency Waves

    Science.gov (United States)

    2007-06-01

    for conducting ionospheric heating experiments in Gakona, Alaska, as part of the High Frequency Active Auroral Research Program ( HAARP ) [5], is being...upgraded. The upgraded HAARP HF transmitting system will be a phased-array antenna of 180 elements. Each element is a cross dipole, which radiates a...supported by the High Frequency Active Auroral Research Program ( HAARP ), the Air Force Research Laboratory at Hanscom Air Force Base, MA, and by the Office

  20. National High Frequency Radar Network (hfrnet) and Pacific Research Efforts

    Science.gov (United States)

    Hazard, L.; Terrill, E. J.; Cook, T.; de Paolo, T.; Otero, M. P.; Rogowski, P.; Schramek, T. A.

    2016-12-01

    The U.S. High Frequency Radar Network (HFRNet) has been in operation for over ten years with representation from 31 organizations spanning academic institutions, state and local government agencies, and private organizations. HFRNet currently holds a collection from over 130 radar installations totaling over 10 million records of surface ocean velocity measurements. HFRNet is a primary example of inter-agency and inter-institutional partnerships for improving oceanographic research and operations. HF radar derived surface currents have been used in several societal applications including coastal search and rescue, oil spill response, water quality monitoring and marine navigation. Central to the operational success of the large scale network is an efficient data management, storage, access, and delivery system. The networking of surface current mapping systems is characterized by a tiered structure that extends from the individual field installations to local regional operations maintaining multiple sites and on to centralized locations aggregating data from all regions. The data system development effort focuses on building robust data communications from remote field locations (sites) for ingestion into the data system via data on-ramps (Portals or Site Aggregators) to centralized data repositories (Nodes). Centralized surface current data enables the aggregation of national surface current grids and allows for ingestion into displays, management tools, and models. The Coastal Observing Research and Development Center has been involved in international relationships and research in the Philippines, Palau, and Vietnam. CORDC extends this IT architecture of surface current mapping data systems leveraging existing developments and furthering standardization of data services for seamless integration of higher level applications. Collaborations include the Philippine Atmospheric Geophysical and Astronomical Services Administration (PAGASA), The Coral Reef Research

  1. Defect Detection in Multi-Layered Structures Using High Frequency Guided Waves

    Science.gov (United States)

    Masserey, B.; Kostson, E.; Fromme, P.

    2011-06-01

    Aircraft structures contain multi-layered components connected by fasteners, where fatigue cracks and disbonds can develop due to cyclic loading conditions and stress concentration. High frequency guided waves propagating along the structure allow for the efficient non-destructive testing of components, such as aircraft wings. However, the sensitivity for the detection of small defects has to be ascertained. The type of multi-layered model structure investigated consists of two adhesively bonded aluminium plate-strips. High frequency ultrasonic wave propagation along the structure and the sensitivity to disbonds and small defects in the metallic layers was investigated and verified experimentally. Preliminary fatigue experiments were carried out and the sensitivity of the guided waves to monitor fatigue crack growth at a fastener hole during cyclic loading was investigated. The measurement setup has the potential for fatigue crack growth monitoring at critical and difficult to access fastener locations from a stand-off distance.

  2. Forecasting Value-at-Risk Using High-Frequency Information

    Directory of Open Access Journals (Sweden)

    Huiyu Huang

    2013-06-01

    Full Text Available in the prediction of quantiles of daily Standard&Poor’s 500 (S&P 500 returns we consider how to use high-frequency 5-minute data. We examine methods that incorporate the high frequency information either indirectly, through combining forecasts (using forecasts generated from returns sampled at different intraday interval, or directly, through combining high frequency information into one model. We consider subsample averaging, bootstrap averaging, forecast averaging methods for the indirect case, and factor models with principal component approach, for both direct and indirect cases. We show that in forecasting the daily S&P 500 index return quantile (Value-at-Risk or VaR is simply the negative of it, using high-frequency information is beneficial, often substantially and particularly so, in forecasting downside risk. Our empirical results show that the averaging methods (subsample averaging, bootstrap averaging, forecast averaging, which serve as different ways of forming the ensemble average from using high-frequency intraday information, provide an excellent forecasting performance compared to using just low-frequency daily information.

  3. Low and high frequency fatigue tests of nodular cast irons

    Directory of Open Access Journals (Sweden)

    A. Vaško

    2017-01-01

    Full Text Available The paper deals with the comparison of fatigue properties of nodular cast iron at low and high frequency cyclic loading. The specimens from three melts of nodular cast iron with different microstructure and mechanical properties were used for experiments. Fatigue tests were carried out at low and high frequency sinusoidal cyclic push-pull loading (stress ratio R = –1 at ambient temperature (T = 20 ± 5 °C. Low frequency fatigue tests were carried out using the fatigue experimental machine Zwick/Roell Amsler 150HFP 5100 at frequency f ≈ 120 Hz; high frequency fatigue tests were carried out using the ultrasonic fatigue testing device KAUP-ZU at frequency f ≈ 20 kHz.

  4. On the Tidal Dissipation of Obliquity

    CERN Document Server

    Rogers, T M

    2013-01-01

    We investigate tidal dissipation of obliquity in hot Jupiters. Assuming an initial random orientation of obliquity and parameters relevant to the observed population, the obliquity of hot Jupiters does not evolve to purely aligned systems. In fact, the obliquity evolves to either prograde, retrograde or 90^{o} orbits where the torque due to tidal perturbations vanishes. This distribution is incompatible with observations which show that hot jupiters around cool stars are generally aligned. This calls into question the viability of tidal dissipation as the mechanism for obliquity alignment of hot Jupiters around cool stars.

  5. Condenser Microphone Protective Grid Correction for High Frequency Measurements

    Science.gov (United States)

    Lee, Erik; Bennett, Reginald

    2010-01-01

    Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

  6. A MEMS-based high frequency x-ray chopper.

    Science.gov (United States)

    Siria, A; Dhez, O; Schwartz, W; Torricelli, G; Comin, F; Chevrier, J

    2009-04-29

    Time-resolved x-ray experiments require intensity modulation at high frequencies (advanced rotating choppers have nowadays reached the kHz range). We here demonstrate that a silicon microlever oscillating at 13 kHz with nanometric amplitude can be used as a high frequency x-ray chopper. We claim that using micro-and nanoelectromechanical systems (MEMS and NEMS), it will be possible to achieve higher frequencies in excess of hundreds of megahertz. Working at such a frequency can open a wealth of possibilities in chemistry, biology and physics time-resolved experiments.

  7. Extended High Frequency Audiometry in Secretory Otitis Media

    OpenAIRE

    Sharma, Deepika; Munjal, Sanjay K.; Panda, Naresh K.

    2012-01-01

    The objective of the present study was to determine the status of extended high frequencies in subjects with secretory otitis media. The study evaluated 30 ears of 20 subjects with secretory otitis media in the age group of 15–30 years. This data was compared with 20 ears of 10 volunteers of the same age group with clinically normal hearing. Pure tone air conduction thresholds were analyzed in three frequency groups: low frequency (LF: 0.25, 0.5, and 1 kHz), high frequency (HF: 2, 4, and 8 kH...

  8. Posture Estimation by Using High Frequency Markers and Kernel Regressions

    Science.gov (United States)

    Ono, Yuya; Iwai, Yoshio; Ishiguro, Hiroshi

    Recently, research fields of augmented reality and robot navigation are actively investigated. Estimating a relative posture between an object and a camera is an important task in these fields. In this paper, we propose a novel method for posture estimation by using high frequency markers and kernel regressions. The markers are embedded in an object's texture in the high frequency domain. We observe the change of spatial frequency of object's texture to estimate a current posture of the object. We conduct experiments to show the effectiveness of our method.

  9. Testing the efficiency of high-frequency foreign exchange market

    Directory of Open Access Journals (Sweden)

    Václav Mastný

    2004-01-01

    Full Text Available This paper deals with the efficiency of the high-frequency foreign exchange market. The objective of this paper is to investigate whether standard statistical tests give the same results for time series resampled at intervals of 15.30 and 60 min. The data used for the purpose of this paper contain major currency pairs such as EUR/USD, GBP/USD and JPY/USD. The results of statistical tests indicate that the high frequency intervals (15-minute are not random and should not be considered independent. On the other hand, tests with lower frequency rates (30 and 60 min indicate rising randomness of the market.

  10. Casimir force between δ -δ' mirrors transparent at high frequencies

    Science.gov (United States)

    Braga, Alessandra N.; Silva, Jeferson Danilo L.; Alves, Danilo T.

    2016-12-01

    We investigate, in the context of a real massless scalar field in 1 +1 dimensions, models of partially reflecting mirrors simulated by Dirac δ -δ' point interactions. In the literature, these models do not exhibit full transparency at high frequencies. In order to provide a more realistic feature for these models, we propose a modified δ -δ' point interaction that enables full transparency in the limit of high frequencies. Taking this modified δ -δ' model into account, we investigate the Casimir force, comparing our results with those found in the literature.

  11. A MEMS-based high frequency x-ray chopper

    Energy Technology Data Exchange (ETDEWEB)

    Siria, A; Schwartz, W; Chevrier, J [Institut Neel, CNRS-Universite Joseph Fourier Grenoble, BP 166, F-38042 Grenoble Cedex 9 (France); Dhez, O; Comin, F [ESRF, 6 rue Jules Horowitz, F-38043 Grenoble Cedex 9 (France); Torricelli, G [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom)

    2009-04-29

    Time-resolved x-ray experiments require intensity modulation at high frequencies (advanced rotating choppers have nowadays reached the kHz range). We here demonstrate that a silicon microlever oscillating at 13 kHz with nanometric amplitude can be used as a high frequency x-ray chopper. We claim that using micro-and nanoelectromechanical systems (MEMS and NEMS), it will be possible to achieve higher frequencies in excess of hundreds of megahertz. Working at such a frequency can open a wealth of possibilities in chemistry, biology and physics time-resolved experiments.

  12. Habitable Climates: The Influence of Obliquity

    CERN Document Server

    Spiegel, David S; Scharf, Caleb A

    2008-01-01

    Without the stabilizing influence of the Moon, the Earth's obliquity could vary significantly. Extrasolar terrestrial planets with the potential to host life may therefore have large obliquities or be subject to strong obliquity variations. We revisit the habitability of oblique planets with an energy balance climate model (EBM) allowing for dynamical transitions to ice-covered snowball states as a result of ice-albedo feedback. Despite the great simplicity of our EBM, it captures reasonably well the seasonal cycle of global energetic fluxes at Earth's surface. It also performs satisfactorily against a full-physics climate model of a highly oblique Earth, in an unusual regime of circulation dominated by heat transport from the poles to the equator. Climates on oblique terrestrial planets can violate global radiative balance through much of their seasonal cycle, which limits the usefulness of simple radiative equilibrium arguments. High obliquity planets have severe climates, with large amplitude seasonal vari...

  13. Momentum transfer from oblique impacts

    Science.gov (United States)

    Schultz, Peter H.; Gault, Donald E.

    1987-05-01

    A completely satisfactory experiment would be in a low gravity environment where the effect of momentum imparted by ejecta impacting the surface can be removed or controlled from momentum transfer during impact. Preliminary estimates can be made using a ballistic pendulum. Such experiments were initiated at the NASA-Ames Vertical Gun Range in order to examine momentum transfer due to impact vaporization for oblique impacts. The preliminary results indicate that momentum from oblique impacts is very inefficient: decreasing with increasing impact velocity and perhaps size; increasing with decreasing density; and increasing with increasing impact angle. At face value, such results minimize the effect of momentum transfer by grazing impact; the more probable impact angles of 30 deg would have a greater effect, contrary to the commonly held impression.

  14. Anaglyph videoanimations from oblique stereoimages

    Science.gov (United States)

    Vozenilek, Vit; Kralik, Tomas

    2015-03-01

    The paper deals with the approach of compiling of animations from a pair of oblique stereoimages. The authors investigated as simple and cheap way as possible to develop such approach which will be available for wide scope of ordinary users with common equipment. They concentrated on three procedures of oblique stereoimage handling to compile sets of images, animations and analogue documents. After capturing construction site by a pair of web cameras the data were corrected, photogrammetrically adjusted (due to radial distortion) and exported. Firstly, a set of anaglyphic images were compiled, then they were trimmed and timeline was inserted. The final anaglyph animations are compiled in various versions. In addition, an anaglyphic book containing 150 images was created in a special way that the user can easily browse through its content. The main outputs are several unique anaglyph products, but more beneficial outputs are developed procedures of anaglyph visualization that can be applied with minor modifications to photographing of any objects.

  15. Stability of oblique shock front

    Institute of Scientific and Technical Information of China (English)

    CHEN; Shuxing(陈恕行)

    2002-01-01

    The stability of the weak planar oblique shock front with respect to the perturbation of the wall is discussed. By the analysis of the formation and the global construction of shock and its asymptotic behaviour for stationary supersonic flow along a smooth rigid wall we obtain the stability of the solution containing a weak planar shock front. The stability can be used to single out a physically reasonable solution together with the entropy condition.

  16. Efficient estimation for ergodic diffusions sampled at high frequency

    DEFF Research Database (Denmark)

    Sørensen, Michael

    A general theory of efficient estimation for ergodic diffusions sampled at high fre- quency is presented. High frequency sampling is now possible in many applications, in particular in finance. The theory is formulated in term of approximate martingale estimating functions and covers a large class...

  17. Modelling financial high frequency data using point processes

    DEFF Research Database (Denmark)

    Hautsch, Nikolaus; Bauwens, Luc

    In this chapter written for a forthcoming Handbook of Financial Time Series to be published by Springer-Verlag, we review the econometric literature on dynamic duration and intensity processes applied to high frequency financial data, which was boosted by the work of Engle and Russell (1997...

  18. Very High Frequency Interleaved Self-Oscillating Resonant SEPIC Converter

    DEFF Research Database (Denmark)

    Kovacevic, Milovan; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    This paper describes analysis and design procedure of an interleaved, self-oscillating resonant SEPIC converter, suitable for operation at very high frequencies (VHF) ranging from 30 MHz to 300 MHz. The presented circuit consists of two resonant SEPIC DC-DC converters, and a capacitive...

  19. High-frequency hearing in seals and sea lions.

    Science.gov (United States)

    Cunningham, Kane A; Reichmuth, Colleen

    2016-01-01

    Existing evidence suggests that some pinnipeds (seals, sea lions, and walruses) can detect underwater sound at frequencies well above the traditional high-frequency hearing limits for their species. This phenomenon, however, is not well studied: Sensitivity patterns at frequencies beyond traditional high-frequency limits are poorly resolved, and the nature of the auditory mechanism mediating hearing at these frequencies is unknown. In the first portion of this study, auditory sensitivity patterns in the 50-180 kHz range were measured for one California sea lion (Zalophus californianus), one harbor seal (Phoca vitulina), and one spotted seal (Phoca largha). Results show the presence of two distinct slope-regions at the high-frequency ends of the audiograms of all three subjects. The first region is characterized by a rapid decrease in sensitivity with increasing frequency-i.e. a steep slope-followed by a region of much less rapid sensitivity decrease-i.e. a shallower slope. In the second portion of this study, a masking experiment was conducted to investigate how the basilar membrane of a harbor seal subject responded to acoustic energy from a narrowband masking noise centered at 140 kHz. The measured masking pattern suggests that the initial, rapid decrease in sensitivity on the high-frequency end of the subject's audiogram is not due to cochlear constraints, as has been previously hypothesized, but rather to constraints on the conductive mechanism. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Very High Frequency Half Bridge DC/DC Converter

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the first, off chip, class DE (resonant half bridge) converter working in the Very High Frequency (VHF) range. The benefits of using half bridge circuits both in the inverter and rectifier part of a VHF resonant dc/dc converter are analyzed and design equations for all...

  1. Current barriers to confine high frequency common mode currents

    NARCIS (Netherlands)

    Moonen, Dominicus Johannes Guilielmus; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2016-01-01

    A commercially produced three phase power line filter is submitted to a Current Barrier (CB) Electro-Magnetic Compatibility (EMC) zoning strategy as an attempt to confine high frequency common mode currents. The intent of the paper is not to show how to build a ’perfect’ filter, since this is known.

  2. Factors Affecting the Benefits of High-Frequency Amplification

    Science.gov (United States)

    Horwitz, Amy R.; Ahlstrom, Jayne B.; Dubno, Judy R.

    2008-01-01

    Purpose: This study was designed to determine the extent to which high-frequency amplification helped or hindered speech recognition as a function of hearing loss, gain-frequency response, and background noise. Method: Speech recognition was measured monaurally under headphones for nonsense syllables low-pass filtered in one-third-octave steps…

  3. High Frequency State-Variable Biquadratic Active Filters

    Directory of Open Access Journals (Sweden)

    T. Dostal

    1998-04-01

    Full Text Available The state-variable (KHN active RC biquadratic filters with good performance in high frequency range , flexibility of outputs (LP, HP, BP, low sensitivities in novel current and hybrid modes, using current conveyors, transimpedance, trans-admittance and current operational amplifiers, are given in this paper.

  4. Fuzzy and conventional control of high-frequency ventilation.

    Science.gov (United States)

    Noshiro, M; Matsunami, T; Takakuda, K; Ryumae, S; Kagawa, T; Shimizu, M; Fujino, T

    1994-07-01

    A high-frequency ventilator was developed, consisting of a single-phase induction motor, an unbalanced mass and a mechanical vibration system. Intermittent positive pressure respiration was combined with high-frequency ventilation to measure end-tidal pCO2. Hysteresis was observed between the rotational frequency of the high-frequency ventilator and end-tidal pCO2. A fuzzy proportional plus integral control system, designed on the basis of the static characteristics of the controlled system and a knowledge of respiratory physiology, successfully regulated end-tidal pCO2. The characteristics of gas exchange under high-frequency ventilation was approximated by a first-order linear model. A conventional PI control system, designed on the basis of the approximated model, regulated end-tidal pCO2 with a performance similar to that of the fuzzy PI control system. The design of the fuzzy control system required less knowledge about the controlled system than that of the conventional control system.

  5. Modelling financial high frequency data using point processes

    DEFF Research Database (Denmark)

    Hautsch, Nikolaus; Bauwens, Luc

    In this chapter written for a forthcoming Handbook of Financial Time Series to be published by Springer-Verlag, we review the econometric literature on dynamic duration and intensity processes applied to high frequency financial data, which was boosted by the work of Engle and Russell (1997......) on autoregressive duration models...

  6. Piping system subjected to seismic hard rock high frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Rydell, Cecilia, E-mail: cecilia.rydell@byv.kth.se [KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Vattenfall AB, SE-169 92 Stockholm (Sweden); Malm, Richard; Ansell, Anders [KTH Royal Institute of Technology, SE-100 44 Stockholm (Sweden)

    2014-10-15

    Highlights: • A study of the influence of support gaps in the analysis of a piping system. • Piping system located within a nuclear power plant reactor containment building. • Piping system subjected to a seismic hard rock high-frequency load. • Comparison of low- and high-frequency seismic loads. • The influence on the stress response of piping and acceleration response of valves. - Abstract: This paper addresses the influence of support gaps in the analyses of a piping system when subjected to a seismic hard rock high-frequency load. The system is located within the reactor containment building of a nuclear power plant and is assessed to be susceptible to high-frequency loads. The stress response of the pipe and the acceleration response of the valves are evaluated for different support gap sizes. It is shown that the inclusion of the support gaps in the analyses reduces the stress response for almost all pipe elements. On the other hand, the acceleration response of the valves is not necessarily reduced by the consideration of the gaps.

  7. High frequency ultrasound imaging of a single-species biofilm

    NARCIS (Netherlands)

    Shemesh, H.; Goertz, D. E.; van der Sluis, L. W. M.; de Jong, N.; Wu, M. K.; Wesselink, P. R.

    2007-01-01

    Objective: This study evaluated the feasibility of a high frequency ultrasound scan to examine the 3D morphology of Streptococcus mutans biofilms grown in vitro. Methods: Six 2-day S. mutans biofilms and six 7-day biofilms were grown on tissue culture membranes and on bovine dentine discs. A sterile

  8. High-frequency Trading, Algorithmic Finance, and the Flash Crash

    DEFF Research Database (Denmark)

    Borch, Christian

    2016-01-01

    The Flash Crash of 6 May 2010 has an interesting status in discussions of high-frequency trading, i.e. fully automated, superfast computerized trading: it is invoked both as an important illustration of how this field of algorithmic trading operates and, more often, as an example of how fully aut...

  9. Free-field calibration of measurement microphones at high frequencies

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Rasmussen, Knud; Torras Rosell, Antoni;

    2011-01-01

    Measurement microphones are typically calibrated in a free field at frequencies up to 50 kHz. This is a sufficiently high frequency for the most of sound measurement applications related with noise assessment. However, other applications such as assessment of the noise emitted by ultrasound clean...

  10. Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

    Science.gov (United States)

    Zhou, Qifa; Lau, Sienting; Wu, Dawei; Shung, K Kirk

    2011-02-01

    Piezoelectric films have recently attracted considerable attention in the development of various sensor and actuator devices such as nonvolatile memories, tunable microwave circuits and ultrasound transducers. In this paper, an overview of the state of art in piezoelectric films for high frequency transducer applications is presented. Firstly, the basic principles of piezoelectric materials and design considerations for ultrasound transducers will be introduced. Following the review, the current status of the piezoelectric films and recent progress in the development of high frequency ultrasonic transducers will be discussed. Then details for preparation and structure of the materials derived from piezoelectric thick film technologies will be described. Both chemical and physical methods are included in the discussion, namely, the sol-gel approach, aerosol technology and hydrothermal method. The electric and piezoelectric properties of the piezoelectric films, which are very important for transducer applications, such as permittivity and electromechanical coupling factor, are also addressed. Finally, the recent developments in the high frequency transducers and arrays with piezoelectric ZnO and PZT thick film using MEMS technology are presented. In addition, current problems and further direction of the piezoelectric films for very high frequency ultrasound application (up to GHz) are also discussed.

  11. Vacuum amplification of the high-frequency electromagnetic radiation

    OpenAIRE

    Vilkovisky, G. A.

    1998-01-01

    When an electrically charged source is capable of both emitting the electromagnetic waves and creating charged particles from the vacuum, its radiation gets so much amplified that only the backreaction of the vacuum makes it finite. The released energy and charge are calculated in the high-frequency approximation. The technique of expectation values is advanced and employed.

  12. On the high frequency spectrum of a classical accretion disc

    CERN Document Server

    Balbus, Steven A

    2014-01-01

    We derive simple and explicit expressions for the high frequency spectrum of a classical accretion disc. Both stress-free and finite stress inner boundaries are considered. A classical accretion disc spectrum with a stress-free inner boundary departs from a Wien spectrum at large $\

  13. Practical techniques for enhancing the high-frequency MASW method

    Science.gov (United States)

    For soil exploration in the vadose zone, a high-frequency multi-channel analysis of surface waves (HF-MASW) method has been developed. In the study, several practical techniques were applied to enhance the overtone image of the HF-MASW method. They included (1) the self-adaptive MASW method using a ...

  14. Fact or friction: jumps at ultra high frequency

    NARCIS (Netherlands)

    K. Christensen; R. Oomen; M. Podolskij

    2011-01-01

    In this paper, we demonstrate that jumps in financial asset prices are not nearly as common as generally thought, and that they account for only a very small proportion of total return variation. We base our investigation on an extensive set of ultra high-frequency equity and foreign exchange rate d

  15. Influence of pore roughness on high-frequency permeability

    NARCIS (Netherlands)

    Cortis, A.; Smeulders, D.M.J.; Guermond, J.L.; Lafarge, D.

    2003-01-01

    The high-frequency behavior of the fluid velocity patterns for smooth and corrugated pore channels is studied. The classical approach of Johnson et al. [J. Fluid Mech. 176, 379 (1987)] for smooth geometries is obtained in different manners, thus clarifying differences with Sheng and Zhou [Phys. Rev.

  16. Collocations of High Frequency Noun Keywords in Prescribed Science Textbooks

    Science.gov (United States)

    Menon, Sujatha; Mukundan, Jayakaran

    2012-01-01

    This paper analyses the discourse of science through the study of collocational patterns of high frequency noun keywords in science textbooks used by upper secondary students in Malaysia. Research has shown that one of the areas of difficulty in science discourse concerns lexis, especially that of collocations. This paper describes a corpus-based…

  17. Occupational exposure to anaesthetic gases and high-frequency audiometry.

    Science.gov (United States)

    Giorgianni, Concetto; Gangemi, Silvia; Tanzariello, Maria Giuseppina; Barresi, Gaetano; Miceli, Ludovica; D'Arrigo, Graziella; Spatari, Giovanna

    2015-09-01

    Occupational exposure to anaestethic gases has been suggested to induce auditory damages. The aim of this study is to investigate high-frequency audiometric responses in subjects exposed to anaesthetic gases, in order to highlight the possible effects on auditory system. The study was performed on a sample of 30 medical specialists of Messina University Anaesthesia and Intensive care. We have used tonal audiometry as well as high-frequency one. We have compared the responses with those obtained in a similar control group not exposed to anaesthetic gases. Results were compared statistically. Results show a strong correlation (p = 0.000) between left and right ear responses to all the audiometric tests. The exposed and the control group run though the standard audiometry analysis plays different audiometric responses up only to higher frequencies (2000 HZ p = 0.009 and 4000 Hz p = 0.04); in high-frequency audiometry, as all other frequencies, the attention is drew to the fact that the sample groups distinguish themselves in a significantly statistic way (10,000 Hz p = 0.025, 12,000 Hz p = 0.008, 14,000 Hz p = 0.026, 16,000 Hz p = 0.08). The highest values are the ones related to exposed subjects both in standard (2000 Hz p = 0.01, 4000 Hz p = 0.02) and in high-frequency audiometry (10,000 Hz p = 0.011, 12,000 Hz p = 0.004, 14,000 Hz p = 0.012, 16,000 Hz p = 0.004). Results, even if preliminary and referred to a low-range sample, show an involvement of the anatomic structure responsible for the perception of high-frequency audiometric responses in subjects exposed to anaesthetic gases. © The Author(s) 2012.

  18. Automated screening for high-frequency hearing loss.

    Science.gov (United States)

    Vlaming, Marcel S M G; MacKinnon, Robert C; Jansen, Marije; Moore, David R

    2014-01-01

    Hearing loss at high frequencies produces perceptual difficulties and is often an early sign of a more general hearing loss. This study reports the development and validation of two new speech-based hearing screening tests in English that focus on detecting hearing loss at frequencies above 2000 Hz. The Internet-delivered, speech-in noise tests used closed target-word sets of digit triplets or consonant-vowel-consonant (CVC) words presented against a speech-shaped noise masker. The digit triplet test uses the digits 0 to 9 (excluding the disyllabic 7), grouped in quasi-random triplets. The CVC test uses simple words (e.g., "cat") selected for the high-frequency spectral content of the consonants. During testing, triplets or CVC words were identified in an adaptive procedure to obtain the speech reception threshold (SRT) in noise. For these new, high-frequency (HF) tests, the noise was low-pass filtered to produce greater masking of the low-frequency speech components, increasing the sensitivity of the test for HF hearing loss. Individual test tokens (digits, CVCs) were first homogenized using a group of 10 normal-hearing (NH) listeners by equalizing intelligibility across tokens at several speech-in-noise levels. Both tests were then validated and standardized using groups of 24 NH listeners and 50 listeners with hearing impairment. Performance on the new high frequency digit triplet (HF-triplet) and CVC (HF-CVC) tests was compared with audiometric hearing loss, and with that on the unfiltered, broadband digit triplet test (BB-triplet) test, and the ASL (Adaptive Sentence Lists) speech-in-noise test. The HF-triplet and HF-CVC test results (SRT) both correlated positively and highly with high-frequency audiometric hearing loss and with the ASL test. SRT for both tests as a function of high-frequency hearing loss increased at nearly three times the rate as that of the BB-triplet test. The intraindividual variability (SD) on the tests was about 2.1 (HF-triplet) and 1

  19. [High-frequency ventilation. I. Distribution of alveolar pressure amplitudes during high frequency oscillation in the lung model].

    Science.gov (United States)

    Theissen, J; Lunkenheimer, P P; Niederer, P; Bush, E; Frieling, G; Lawin, P

    1987-09-01

    The pattern of intrapulmonary pressure distribution was studied during high-frequency ventilation in order to explain the inconsistent results reported in the literature. Methods. Pressure and flow velocity (hot-wire anemometry) were measured in different lung compartments: 1. In transalveolar chambers sealed to the perforated pleural surfaces of dried pig lungs; 2. In emphysema-simulating airbags sealed to the isolated bronchial trees of dried pig lungs; and 3. In transalveolar chambers sealed to the perforated pleural surfaces of freshly excised pig lungs. Results. 1. The pressure amplitudes change from one area to another and depending on the exciting frequency. 2. High-frequency oscillation is associated with an increase in pressure amplitude when the exciting frequency rises, whereas with conventional high-frequency jet ventilation the pressure amplitude is more likely to decrease with frequency. 3. During high-frequency jet ventilation the local pressure amplitude changes with the position of the tube in the trachea rather than with the exciting frequency. 4. When the volume of the measuring chamber is doubled the resulting pressure amplitude falls to half the control value. 5. The pressure amplitude and mean pressure measured in the transalveolar chamber vary more or less independently from the peak flow velocity. High-frequency ventilation is thus seen to be a frequency-dependant, inhomogeneous mode of ventilation that can essentially be homogenized by systematically changing the exciting frequency. The frequency-dependant response to different lung areas to excitation is likely to result from an intrabronchially-localized aerodynamic effect rather than the mechanical properties of the lung parenchyma.

  20. Slow high-frequency effects in mechanics: problems, solutions, potentials

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    Strong high-frequency excitation (HFE) may change the ‘slow’ (i.e. effective or average) properties of mechanical systems, e.g. their stiffness, natural frequencies, equilibriums, equilibrium stability, and bifurcation paths. This tutorial describes three general HFE effects: Stiffening – an appa......Strong high-frequency excitation (HFE) may change the ‘slow’ (i.e. effective or average) properties of mechanical systems, e.g. their stiffness, natural frequencies, equilibriums, equilibrium stability, and bifurcation paths. This tutorial describes three general HFE effects: Stiffening...... and compared: The Method of Direct Separation of Motions, the Method of Averaging, and the Method of Multiple Scales. The tutorial concludes by suggesting that more vibration experts, researchers and students should know about HFE effects, for the benefit not only of general vibration troubleshooting, but also...

  1. Planck 2013 results. VI. High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143,217, 353, 545......, these two high frequency channels are calibrated to within 5% and the 353 GHz channel to the percent level. The 100 and217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 ..., and 857 GHz with an angular resolution ranging from 9.07 to 4.06. The detector noise per (effective) beam solid angle is respectively,10, 6 , 12, and 39 µK in the four lowest HFI frequency channels (100-353 GHz) and 13 and 14 kJy sr-1 in the 545 and 857 GHz channels. Relativeto the 143 GHz channel...

  2. Extraction of ULSI Interconnect Resistance at High Frequencies

    Institute of Scientific and Technical Information of China (English)

    XIAO Xia; JIAN Duanduan; YAO Suying; ZHANG Shengcai; RUAN Gang

    2005-01-01

    Correct extraction of the ultra-large-scale integrated (ULSI) interconnect components at hight frequencies is very important for evaluating electrical performances of high-speed ULSI circuits.In this paper, the extraction of the interconnect resistance at high frequencies is derived from the Ohm′s law and verified by the software FastHenry.The results are also compared with those of another resistance formula originated from the effective area of the current flowing. The applicability of these two formulae is discussed.The influence of the interconnect geometry on the resistance at high frequencies is studied.The computation indicates that the effect of frequency on the resistance is weak when the skin depth is larger than half of the short side of the rectangular interconnect cross section.With further increase of frequency, the resistance increases obviously. Results imply that conductor with a square cross section exhibits the largest resistance for rectangular conductors of constant cross section area.

  3. Extended High Frequency Audiometry in Polycystic Ovary Syndrome

    Directory of Open Access Journals (Sweden)

    Cuneyt Kucur

    2013-01-01

    and BMI of PCOS and control groups were comparable. Each subject was tested with low (250–2000 Hz, high (4000–8000 Hz, and extended high frequency audiometry (8000–20000. Hormonal and biochemical values including LH, LH/FSH, testosterone, fasting glucose, fasting insulin, HOMA-I, and CRP were calculated. Results. PCOS patients showed high levels of LH, LH/FSH, testosterone, fasting insulin, glucose, HOMA-I, and CRP levels. The hearing thresholds of the groups were similar at frequencies of 250, 500, 1000, 2000, and 4000 Hz; statistically significant difference was observed in 8000–14000 Hz in PCOS group compared to control group. Conclusion. PCOS patients have hearing impairment especially in extended high frequencies. Further studies are needed to help elucidate the mechanism behind hearing impairment in association with PCOS.

  4. On the high frequency polarization of pulsar radio emission

    CERN Document Server

    Von Hoensbroech, A; Krawczyk, A

    1998-01-01

    We have analyzed the polarization properties of pulsars at an observing frequency of 4.9 GHz. Together with low frequency data, we are able to trace polarization profiles over more than three octaves into an interesting frequency regime. At those high frequencies the polarization properties often undergo important changes such as significant depolarization. A detailed analysis allowed us to identify parameters, which regulate those changes. A significant correlation was found between the integrated degree of polarization and the loss of rotational energy E^dot. The data were also used to review the widely established pulsar profile classification scheme of core- and cone-type beams. We have discovered the existence of pulsars which show a strongly increasing degree of circular polarization towards high frequencies. Previously unpublished average polarization profiles, recorded at the 100m Effelsberg radio telescope, are presented for 32 radio pulsars at 4.9 GHz. The data were used to derive polarimetric param...

  5. Propagation of high frequency waves in the quiet solar atmosphere

    Directory of Open Access Journals (Sweden)

    Andić A.

    2008-01-01

    Full Text Available High-frequency waves (5 mHz to 20 mHz have previously been suggested as a source of energy accounting for partial heating of the quiet solar atmosphere. The dynamics of previously detected high-frequency waves is analyzed here. Image sequences were taken by using the German Vacuum Tower Telescope (VTT, Observatorio del Teide, Izana, Tenerife, with a Fabry-Perot spectrometer. The data were speckle reduced and analyzed with wavelets. Wavelet phase-difference analysis was performed to determine whether the waves propagate. We observed the propagation of waves in the frequency range 10 mHz to 13 mHz. We also observed propagation of low-frequency waves in the ranges where they are thought to be evanescent in the regions where magnetic structures are present.

  6. Propagation of High Frequency Waves in the Quiet Solar Atmosphere

    Directory of Open Access Journals (Sweden)

    Andić, A.

    2008-12-01

    Full Text Available High-frequency waves (5 mHz to 20 mHz have previously been suggested as a source of energy accounting for partial heating of the quiet solar atmosphere. The dynamics of previously detected high-frequency waves is analysed here. Image sequences were taken by using the German Vacuum Tower Telescope (VTT, Observatorio del Teide, Izana, Tenerife, with a Fabry-Perot spectrometer. The data were speckle reduced and analysed with wavelets. Wavelet phase-difference analysis was performed to determine whether the waves propagate. We observed the propagation of waves in the frequency range 10 mHz to 13 mHz. We also observed propagation of low-frequency waves in the ranges where they are thought to be evanescent in the regions where magnetic structures are present.

  7. How high frequency trading affects a market index.

    Science.gov (United States)

    Kenett, Dror Y; Ben-Jacob, Eshel; Stanley, H Eugene; Gur-Gershgoren, Gitit

    2013-01-01

    The relationship between a market index and its constituent stocks is complicated. While an index is a weighted average of its constituent stocks, when the investigated time scale is one day or longer the index has been found to have a stronger effect on the stocks than vice versa. We explore how this interaction changes in short time scales using high frequency data. Using a correlation-based analysis approach, we find that in short time scales stocks have a stronger influence on the index. These findings have implications for high frequency trading and suggest that the price of an index should be published on shorter time scales, as close as possible to those of the actual transaction time scale.

  8. Skyrmion-based high-frequency signal generator

    Science.gov (United States)

    Luo, Shijiang; Zhang, Yue; Shen, Maokang; Ou-Yang, Jun; Yan, Baiqian; Yang, Xiaofei; Chen, Shi; Zhu, Benpeng; You, Long

    2017-03-01

    Many concepts for skyrmion-based devices have been proposed, and most of their possible applications are based on the motion of skyrmions driven by a dc current in an area with a constricted geometry. However, skyrmion motion driven by a pulsed current has not been investigated so far. In this work, we propose a skyrmion-based high-frequency signal generator based on the pulsed-current-driven circular motion of skyrmions in a square-shaped film by micromagnetic simulation. The results indicate that skyrmions can move in a closed curve with central symmetry. The trajectory and cycle period can be adjusted by tuning the size of the film, the current density, the Dzyaloshinskii-Moriya interaction constant, and the local in-plane magnetic anisotropy. The period can be tuned from several nanoseconds to tens of nanoseconds, which offers the possibility to prepare high-frequency signal generator based on skyrmions.

  9. High-frequency Oscillations in Eyewalls of Tropical Cyclones

    Science.gov (United States)

    Li, Weibiao; Chen, Shumin

    2017-04-01

    High-frequency oscillations, with periods of about 2 hours, are first identified by applying wavelet analysis to observed minutely wind speeds around the eye and eyewall of tropical cyclones (TCs). Analysis of a model simulation of Typhoon Hagupit (2008) shows that the oscillations also occur in the intensity of TC, vertical motion, convergence activity and air density around the eyewall. Sequences of oscillations in these variables follow a certain order. In a typical cycle, the drop of density in the planetary boundary layer (PBL) is followed by an increase in the inward radial wind; this enhanced frictional convergence causes increase in density, followed by a decrease in the inward radial wind. The increase in convergence in the PBL causes increase of updraft at the top of the PBL, followed by high vertical velocity at high altitude of 8-10 km, then the increase of the maximum wind speed, and vice versa. Key words: tropical cyclone, high-frequency oscillations, eyewall, intensity

  10. Propagation of High Frequency Waves in the Quiet Solar Atmosphere

    CERN Document Server

    Andić, Aleksandra

    2008-01-01

    High-frequency waves (5 mHz to 20mHz) have previously been suggested as a source of energy accounting partial heating of the quiet solar atmosphere. The dynamics of previously detected high-frequency waves is analysed here. Image sequences are taken using the German Vacuum Tower Telescope (VTT), Observatorio del Teide, Izana, Tenerife, with a Fabry-Perot spectrometer. The data were speckle reduced and analyzed with wavelets. Wavelet phase-difference analysis is performed to determine whether the waves propagate. We observe the propagation of waves in the frequency range 10mHz to 13mHz. We also observe propagation of low-frequency waves in the ranges where they are thought to be evanescent in regions where magnetic structures are present.

  11. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  12. Generation of sheet currents by high frequency fast MHD waves

    Energy Technology Data Exchange (ETDEWEB)

    Núñez, Manuel, E-mail: mnjmhd@am.uva.es

    2016-07-01

    The evolution of fast magnetosonic waves of high frequency propagating into an axisymmetric equilibrium plasma is studied. By using the methods of weakly nonlinear geometrical optics, it is shown that the perturbation travels in the equatorial plane while satisfying a transport equation which enables us to predict the time and location of formation of shock waves. For plasmas of large magnetic Prandtl number, this would result into the creation of sheet currents which may give rise to magnetic reconnection and destruction of the original equilibrium. - Highlights: • Regular solutions of quasilinear hyperbolic systems may evolve into shocks. • The shock location is found for high frequency fast MHD waves. • The result is applied to static axisymmetric equilibria. • The previous process may lead to the formation of sheet currents and destruction of the equilibrium.

  13. High Frequency Amplitude Detector for GMI Magnetic Sensors

    Directory of Open Access Journals (Sweden)

    Aktham Asfour

    2014-12-01

    Full Text Available A new concept of a high-frequency amplitude detector and demodulator for Giant-Magneto-Impedance (GMI sensors is presented. This concept combines a half wave rectifier, with outstanding capabilities and high speed, and a feedback approach that ensures the amplitude detection with easily adjustable gain. The developed detector is capable of measuring high-frequency and very low amplitude signals without the use of diode-based active rectifiers or analog multipliers. The performances of this detector are addressed throughout the paper. The full circuitry of the design is given, together with a comprehensive theoretical study of the concept and experimental validation. The detector has been used for the amplitude measurement of both single frequency and pulsed signals and for the demodulation of amplitude-modulated signals. It has also been successfully integrated in a GMI sensor prototype. Magnetic field and electrical current measurements in open- and closed-loop of this sensor have also been conducted.

  14. How High Frequency Trading Affects a Market Index

    Science.gov (United States)

    Kenett, Dror Y.; Ben-Jacob, Eshel; Stanley, H. Eugene; gur-Gershgoren, Gitit

    2013-01-01

    The relationship between a market index and its constituent stocks is complicated. While an index is a weighted average of its constituent stocks, when the investigated time scale is one day or longer the index has been found to have a stronger effect on the stocks than vice versa. We explore how this interaction changes in short time scales using high frequency data. Using a correlation-based analysis approach, we find that in short time scales stocks have a stronger influence on the index. These findings have implications for high frequency trading and suggest that the price of an index should be published on shorter time scales, as close as possible to those of the actual transaction time scale. PMID:23817553

  15. Very High Frequency Switch-Mode Power Supplies

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre

    The importance of technology and electronics in our daily life is constantly increasing. At the same time portability and energy efficiency are currently some of the hottest topics. This creates a huge need for power converters in a compact form factor and with high efficiency, which can supply...... these electronic devices. This calls for new technologies in order to miniaturize the power electronics of today. One way to do this is by increasing the switching frequency dramatically and develop very high frequency switch mode power supplies. If these converters can be designed to operate efficiently, a huge...... of technologies for very high frequency switch mode power supplies. At these highly elevated frequencies normal bulky magnetics with heavy cores consisting of rare earth materials, can be replaced by air core inductors embedded in the printed circuit board. This is investigated thoroughly and both spirals...

  16. Piezoelectric films for high frequency ultrasonic transducers in biomedical applications

    OpenAIRE

    Zhou, Qifa; Lau, Sienting; WU, DAWEI; Shung, K. Kirk

    2011-01-01

    Piezoelectric films have recently attracted considerable attention in the development of various sensor and actuator devices such as nonvolatile memories, tunable microwave circuits and ultrasound transducers. In this paper, an overview of the state of art in piezoelectric films for high frequency transducer applications is presented. Firstly, the basic principles of piezoelectric materials and design considerations for ultrasound transducers will be introduced. Following the review, the curr...

  17. Strange effects of strong high-frequency excitation

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    2003-01-01

    Three general effects of mechanical high-frequency excitation (HFE) are described: Stiffening - an apparent change in the stiffness associated with an equilibrium; Biasing - a tendency for a system to move towards a particular state which does not exist or is unstable without HFE; and Smoothening...... - a tendency for discontinuities to be apparently smeared out by HFE. Studies of specific physical systems as well as more general models are described....

  18. Modeling high-frequency capacitance in SOI MOS capacitors

    Science.gov (United States)

    Łukasiak, Lidia; Jasiński, Jakub; Beck, Romuald B.; Ikraiam, Fawzi A.

    2016-12-01

    This paper presents a model of high frequency capacitance of a SOI MOSCAP. The capacitance in strong inversion is described with minority carrier redistribution in the inversion layer taken into account. The efficiency of the computational process is significantly improved. Moreover, it is suitable for the simulation of thin-film SOI structures. It may also be applied to the characterization of non-standard SOI MOSCAPS e.g. with nanocrystalline body.

  19. Measurements Of High Frequency Electromagnetic Waves In Center Of Mus

    OpenAIRE

    etem, taha; ABBASOV, Teymuraz

    2016-01-01

    All electrically powered devices cause electromagnetic wave exposure onhuman body and we use them nearly every moment in a day. Mobile phones,computers, televisions, hair dryers, lighting systems, etc. they all useelectricity and naturally radiate electromagnetic waves. Effects ofelectromagnetic waves are not clear but international organizations definelimit values depending on epidemiological studies in this field. In this studywe measure high frequency electromagnetic waves in city center o...

  20. High-Frequency Chest Compression: A Summary of the Literature

    OpenAIRE

    Dosman, Cara F; Jones, Richard L

    2005-01-01

    The purpose of the present literature summary is to describe high-frequency chest compression (HFCC), summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have...

  1. Clinical Implications High Frequency Chest Wall Oscillation (HFCWO)

    OpenAIRE

    Mantellini E.; Perrero L.; Petrozzino S.; Gatta A.; Bona S.

    2012-01-01

    Purpose: patients with neuromuscular diseases presents an high incidence of respiratory infections favoured by stagnation of deep bronchial secretions and deficit of cough. The aim of the study is to evaluate the correct treatment of this condition and the role of High Frequency Chest Wall Oscillation (HFCWO) in helping the removal of bronchial secretions and reduce the incidence of infections in patients with neuromuscular disease.Methods: analysis of the current bibliography related to resp...

  2. Acoustic trapping with a high frequency linear phased array

    OpenAIRE

    Zheng, Fan; Ying LI; Hsu, Hsiu-Sheng; Liu, Changgeng; Tat Chiu, Chi; Lee, Changyang; Ham Kim, Hyung; Shung, K. Kirk

    2012-01-01

    A high frequency ultrasonic phased array is shown to be capable of trapping and translating microparticles precisely and efficiently, made possible due to the fact that the acoustic beam produced by a phased array can be both focused and steered. Acoustic manipulation of microparticles by a phased array is advantageous over a single element transducer since there is no mechanical movement required for the array. Experimental results show that 45 μm diameter polystyrene microspheres can be eas...

  3. Ultra high frequency induction welding of powder metal compacts

    Energy Technology Data Exchange (ETDEWEB)

    Cavdar, U.; Gulsahin, I.

    2014-10-01

    The application of the iron based Powder Metal (PM) compacts in Ultra High Frequency Induction Welding (UHFIW) were reviewed. These PM compacts are used to produce cogs. This study investigates the methods of joining PM materials enforceability with UHFIW in the industry application. Maximum stress and maximum strain of welded PM compacts were determined by three point bending and strength tests. Microhardness and microstructure of induction welded compacts were determined. (Author)

  4. Factors controlling high-frequency radiation from extended ruptures

    Science.gov (United States)

    Beresnev, Igor A.

    2017-09-01

    Small-scale slip heterogeneity or variations in rupture velocity on the fault plane are often invoked to explain the high-frequency radiation from earthquakes. This view has no theoretical basis, which follows, for example, from the representation integral of elasticity, an exact solution for the radiated wave field. The Fourier transform, applied to the integral, shows that the seismic spectrum is fully controlled by that of the source time function, while the distribution of final slip and rupture acceleration/deceleration only contribute to directivity. This inference is corroborated by the precise numerical computation of the full radiated field from the representation integral. We compare calculated radiation from four finite-fault models: (1) uniform slip function with low slip velocity, (2) slip function spatially modulated by a sinusoidal function, (3) slip function spatially modulated by a sinusoidal function with random roughness added, and (4) uniform slip function with high slip velocity. The addition of "asperities," both regular and irregular, does not cause any systematic increase in the spectral level of high-frequency radiation, except for the creation of maxima due to constructive interference. On the other hand, an increase in the maximum rate of slip on the fault leads to highly amplified high frequencies, in accordance with the prediction on the basis of a simple point-source treatment of the fault. Hence, computations show that the temporal rate of slip, not the spatial heterogeneity on faults, is the predominant factor forming the high-frequency radiation and thus controlling the velocity and acceleration of the resulting ground motions.

  5. High-frequency audibility: benefits for hearing-impaired listeners.

    Science.gov (United States)

    Hogan, C A; Turner, C W

    1998-07-01

    The present study was a systematic investigation of the benefit of providing hearing-impaired listeners with audible high-frequency speech information. Five normal-hearing and nine high-frequency hearing-impaired listeners identified nonsense syllables that were low-pass filtered at a number of cutoff frequencies. As a means of quantifying audibility for each condition, Articulation Index (AI) was calculated for each condition for each listener. Most hearing-impaired listeners demonstrated an improvement in speech recognition as additional audible high-frequency information was provided. In some cases for more severely impaired listeners, increasing the audibility of high-frequency speech information resulted in no further improvement in speech recognition, or even decreases in speech recognition. A new measure of how well hearing-impaired listeners used information within specific frequency bands called "efficiency" was devised. This measure compared the benefit of providing a given increase in speech audibility to a hearing-impaired listener to the benefit observed in normal-hearing listeners for the same increase in speech audibility. Efficiencies were calculated using the old AI method and the new AI method (which takes into account the effects of high speech presentation levels). There was a clear pattern in the results suggesting that as the degree of hearing loss at a given frequency increased beyond 55 dB HL, the efficacy of providing additional audibility to that frequency region was diminished, especially when this degree of hearing loss was present at frequencies of 4000 Hz and above. A comparison of analyses from the "old" and "new" AI procedures suggests that some, but not all, of the deficiencies of speech recognition in these listeners was due to high presentation levels.

  6. High-frequency capillary waves excited by oscillating microbubbles

    CERN Document Server

    Pommella, Angelo; Poulichet, Vincent; Garbin, Valeria

    2013-01-01

    This fluid dynamics video shows high-frequency capillary waves excited by the volumetric oscillations of microbubbles near a free surface. The frequency of the capillary waves is controlled by the oscillation frequency of the microbubbles, which are driven by an ultrasound field. Radial capillary waves produced by single bubbles and interference patterns generated by the superposition of capillary waves from multiple bubbles are shown.

  7. The chaotic obliquity of Mars

    Science.gov (United States)

    Touma, Jihad; Wisdom, Jack

    1993-01-01

    The discovery (by Laskar, 1989, 1990) that the evolution of the solar system is chaotic, made in a numerical integration of the averaged secular approximation of the equations of motions for the planets, was confirmed by Sussman and Wisdom (1992) by direct numerical integration of the whole solar system. This paper presents results of direct integrations of the rotation of Mars in the chaotically evolved planetary system, made using the same model as that used by Sussman and Wisdom. The numerical integration shows that the obliquity of Mars undergoes large chaotic variations, which occur as the system evolves in the chaotic zone associated with a secular spin-orbit resonance.

  8. Clinical Implications High Frequency Chest Wall Oscillation (HFCWO

    Directory of Open Access Journals (Sweden)

    Mantellini E.

    2012-01-01

    Full Text Available Purpose: patients with neuromuscular diseases presents an high incidence of respiratory infections favoured by stagnation of deep bronchial secretions and deficit of cough. The aim of the study is to evaluate the correct treatment of this condition and the role of High Frequency Chest Wall Oscillation (HFCWO in helping the removal of bronchial secretions and reduce the incidence of infections in patients with neuromuscular disease.Methods: analysis of the current bibliography related to respiratory infections and neuromuscular disease. PCEF (Peak Cough Expiratory Flow is used as a standardized indicator of efficiency of cough.Results: the High Frequency Chest Wall Oscillation (HFCWO is useful, in cases of increased production of mucus and impairment of muco-ciliary clearance, to remove the tracheobronchial secretions and reduce the incidence of infections.Conclusions: the correct approach to patients with neuromuscular disease and frequent respiratory infections is focused on treatment of cough ineffective and management of bronchial secretions. High Frequency Chest Wall Oscillation (HFCWO (VEST has a central role in treatment of cough ineffective and management of bronchial secretions reducing respiratory infections.

  9. Occupational hearing loss: tonal audiometry X high frequencies audiometry

    Directory of Open Access Journals (Sweden)

    Lauris, José Roberto Pereira

    2009-09-01

    Full Text Available Introduction: Studies on the occupational exposure show that noise has been reaching a large part of the working population around the world, and NIHL (noise-induced hearing loss is the second most frequent disease of the hearing system. Objective: To review the audiometry results of employees at the campus of the University of São Paulo, Bauru. Method: 40 audiometry results were analyzed between 2007 and 2008, whose ages comprised between 32 and 59 years, of both sexes and several professions: gardeners, maintenance technicians, drivers etc. The participants were divided into 2 groups: those with tonal thresholds within acceptable thresholds and those who presented auditory thresholds alterations, that is tonal thresholds below 25 dB (NA in any frequency (Administrative Rule no. 19 of the Ministry of Labor 1998. In addition to the Conventional Audiologic Evaluation (250Hz to 8.000Hz we also carried out High Frequencies Audiometry (9000Hz, 10000Hz, 11200Hz, 12500Hz, 14000Hz and 16000Hz. Results: According to the classification proposed by FIORINI (1994, 25.0% (N=10 they presented with NIHL suggestive audiometric configurations. The results of high frequencies Audiometry confirmed worse thresholds than those obtained in the conventional audiometry in the 2 groups evaluated. Conclusion: The use of high frequencies audiometry proved to be an important register as a hearing alteration early detection method.

  10. Calibration Procedures on Oblique Camera Setups

    Science.gov (United States)

    Kemper, G.; Melykuti, B.; Yu, C.

    2016-06-01

    Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager) is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna -IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first step with the help of

  11. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  12. Frequency dependence of lung volume changes during superimposed high-frequency jet ventilation and high-frequency jet ventilation.

    Science.gov (United States)

    Sütterlin, R; Priori, R; Larsson, A; LoMauro, A; Frykholm, P; Aliverti, A

    2014-01-01

    Superimposed high-frequency jet ventilation (SHFJV) has proved to be safe and effective in clinical practice. However, it is unclear which frequency range optimizes ventilation and gas exchange. The aim of this study was to systematically compare high-frequency jet ventilation (HFJV) with HFJV by assessing chest wall volume variations (ΔEEV(CW)) and gas exchange in relation to variable high frequency. SHFJV or HFJV were used alternatively to ventilate the lungs of 10 anaesthetized pigs (21-25 kg). The low-frequency component was kept at 16 min(-1) in SHFJV. In both modes, high frequencies ranging from 100 to 1000 min(-1) were applied in random order and ventilation was maintained for 5 min in all modalities. Chest wall volume variations were obtained using opto-electronic plethysmography. Airway pressures and arterial blood gases were measured repeatedly. SHFJV increased ΔEEV(CW) compared with HFJV; the difference ranged from 43 to 68 ml. Tidal volume (V(T)) was always >240 ml during SHFJV whereas during HFJV ranged from 92 ml at the ventilation frequency of 100 min(-1) to negligible values at frequencies >300 min(-1). We observed similar patterns for Pa(O₂) and Pa(CO₂). SHFJV provided generally higher, frequency-independent oxygenation (Pa(O₂) at least 32.0 kPa) and CO₂ removal (Pa(CO₂) ∼5.5 kPa), whereas HFJV led to hypoxia and hypercarbia at higher rates (Pa(O₂) 10 kPa at f(HF)>300 min(-1)). In a porcine model, SHFJV was more effective in increasing end-expiratory volume than single-frequency HFJV, but both modes may provide adequate ventilation in the absence of airway obstruction and respiratory disease, except for HFJV at frequencies ≥300 min(-1).

  13. Obliquity forcing of low-latitude climate

    NARCIS (Netherlands)

    Bosmans, J.H.C.; Hilgen, F.J.; Tuenter, Erik; Lourens, L.J.

    2015-01-01

    The influence of obliquity, the tilt of the Earth's rotational axis, on incoming solar radiation at low latitudes is small, yet many tropical and subtropical palaeoclimate records reveal a clear obliquity signal. Several mechanisms have been proposed to explain this signal, such as the remote

  14. Obliquity forcing of low-latitude climate

    NARCIS (Netherlands)

    Bosmans, J.H.C.; Hilgen, F.J.; Tuenter, Erik; Lourens, L.J.

    2015-01-01

    The influence of obliquity, the tilt of the Earth's rotational axis, on incoming solar radiation at low latitudes is small, yet many tropical and subtropical palaeoclimate records reveal a clear obliquity signal. Several mechanisms have been proposed to explain this signal, such as the remote influe

  15. High Frequency Ground Motion from Finite Fault Rupture Simulations

    Science.gov (United States)

    Crempien, Jorge G. F.

    There are many tectonically active regions on earth with little or no recorded ground motions. The Eastern United States is a typical example of regions with active faults, but with low to medium seismicity that has prevented sufficient ground motion recordings. Because of this, it is necessary to use synthetic ground motion methods in order to estimate the earthquake hazard a region might have. Ground motion prediction equations for spectral acceleration typically have geometric attenuation proportional to the inverse of distance away from the fault. Earthquakes simulated with one-dimensional layered earth models have larger geometric attenuation than the observed ground motion recordings. We show that as incident angles of rays increase at welded boundaries between homogeneous flat layers, the transmitted rays decrease in amplitude dramatically. As the receiver distance increases away from the source, the angle of incidence of up-going rays increases, producing negligible transmitted ray amplitude, thus increasing the geometrical attenuation. To work around this problem we propose a model in which we separate wave propagation for low and high frequencies at a crossover frequency, typically 1Hz. The high-frequency portion of strong ground motion is computed with a homogeneous half-space and amplified with the available and more complex one- or three-dimensional crustal models using the quarter wavelength method. We also make use of seismic coda energy density observations as scattering impulse response functions. We incorporate scattering impulse response functions into our Green's functions by convolving the high-frequency homogeneous half-space Green's functions with normalized synthetic scatterograms to reproduce scattering physical effects in recorded seismograms. This method was validated against ground motion for earthquakes recorded in California and Japan, yielding results that capture the duration and spectral response of strong ground motion.

  16. Engineering Graphene Conductivity for Flexible and High-Frequency Applications.

    Science.gov (United States)

    Samuels, Alexander J; Carey, J David

    2015-10-14

    Advances in lightweight, flexible, and conformal electronic devices depend on materials that exhibit high electrical conductivity coupled with high mechanical strength. Defect-free graphene is one such material that satisfies both these requirements and which offers a range of attractive and tunable electrical, optoelectronic, and plasmonic characteristics for devices that operate at microwave, terahertz, infrared, or optical frequencies. Essential to the future success of such devices is therefore the ability to control the frequency-dependent conductivity of graphene. Looking to accelerate the development of high-frequency applications of graphene, here we demonstrate how readily accessible and processable organic and organometallic molecules can efficiently dope graphene to carrier densities in excess of 10(13) cm(-2) with conductivities at gigahertz frequencies in excess of 60 mS. In using the molecule 3,6-difluoro-2,5,7,7,8,8-hexacyanoquinodimethane (F2-HCNQ), a high charge transfer (CT) of 0.5 electrons per adsorbed molecule is calculated, resulting in p-type doping of graphene. n-Type doping is achieved using cobaltocene and the sulfur-containing molecule tetrathiafulvalene (TTF) with a CT of 0.41 and 0.24 electrons donated per adsorbed molecule, respectively. Efficient CT is associated with the interaction between the π electrons present in the molecule and in graphene. Calculation of the high-frequency conductivity shows dispersion-less behavior of the real component of the conductivity over a wide range of gigahertz frequencies. Potential high-frequency applications in graphene antennas and communications that can exploit these properties and the broader impacts of using molecular doping to modify functional materials that possess a low-energy Dirac cone are also discussed.

  17. Computation of High-Frequency Waves with Random Uncertainty

    KAUST Repository

    Malenova, Gabriela

    2016-01-06

    We consider the forward propagation of uncertainty in high-frequency waves, described by the second order wave equation with highly oscillatory initial data. The main sources of uncertainty are the wave speed and/or the initial phase and amplitude, described by a finite number of random variables with known joint probability distribution. We propose a stochastic spectral asymptotic method [1] for computing the statistics of uncertain output quantities of interest (QoIs), which are often linear or nonlinear functionals of the wave solution and its spatial/temporal derivatives. The numerical scheme combines two techniques: a high-frequency method based on Gaussian beams [2, 3], a sparse stochastic collocation method [4]. The fast spectral convergence of the proposed method depends crucially on the presence of high stochastic regularity of the QoI independent of the wave frequency. In general, the high-frequency wave solutions to parametric hyperbolic equations are highly oscillatory and non-smooth in both physical and stochastic spaces. Consequently, the stochastic regularity of the QoI, which is a functional of the wave solution, may in principle below and depend on frequency. In the present work, we provide theoretical arguments and numerical evidence that physically motivated QoIs based on local averages of |uE|2 are smooth, with derivatives in the stochastic space uniformly bounded in E, where uE and E denote the highly oscillatory wave solution and the short wavelength, respectively. This observable related regularity makes the proposed approach more efficient than current asymptotic approaches based on Monte Carlo sampling techniques.

  18. A 300 Hz high frequency thermoacoustically driven pulse tube cooler

    Institute of Scientific and Technical Information of China (English)

    ZHU ShangLong; YU GuoYao; ZHANG XiaoDong; DAI Wei; LUO ErCang; ZHOU Yuan

    2008-01-01

    This article introduces the latest progress of a 300 Hz thermoacoustically driven pulse tube cooler. Based on the experience of former experiments, improvements have been made in the standing-wave engine, pulse tube cooler and their coupling mechanism. An inlet pressure ratio of 1.248 was obtained with the mean pressure and heating power of 4.13 MPa and 1760 W, respectively. A lowest no-load temperature of 69.5 K has been reached under this condition. This is the first time for thermoacousti-cally driven pulse tube coolers to reach the temperature below 76 K with such a high frequency.

  19. On the Ongoing Evolution of Very High Frequency Power Supplies

    DEFF Research Database (Denmark)

    Knott, Arnold; Andersen, Toke Meyer; Kamby, Peter

    2013-01-01

    in radio frequency transmission equipment helps to overcome those. However those circuits were not designed to meet the same requirements as power converters. This paper summarizes the contributions in recent years in application of very high frequency (VHF) technologies in power electronics, describes......The ongoing demand for smaller and lighter power supplies is driving the motivation to increase the switching frequencies of power converters. Drastic increases however come along with new challenges, namely the increase of switching losses in all components. The application of power circuits used...

  20. Articulated pipes conveying fluid pulsating with high frequency

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard

    1999-01-01

    Stability and nonlinear dynamics of two articulated pipes conveying fluid with a high-frequency pulsating component is investigated. The non-autonomous model equations are converted into autonomous equations by approximating the fast excitation terms with slowly varying terms. The downward hanging...... pipe position will lose stability if the mean flow speed exceeds a certain critical value. Adding a pulsating component to the fluid flow is shown to stabilize the hanging position for high values of the ratio between fluid and pipe-mass, and to marginally destabilize this position for low ratios...

  1. High frequency microphone measurements for transition detection on airfoils

    DEFF Research Database (Denmark)

    Døssing, Mads

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by ’LM Glasfiber’, Denmark. The present report describes the dataanalysis, with special attention given...... pressure) and Tollmien-Schlichting frequencies. The tests were made at Reynolds and Mach numbers corresponding to the operating conditions of a typical horizontal axis wind turbine (HAWT). The Risø B1-18, Risø C2-18 and NACA0015 profiles were tested and the measured transition points are reported....

  2. High frequency chest compression therapy: a case study.

    Science.gov (United States)

    Butler, S; O'Neill, B

    1995-01-01

    A new device, the ThAIRapy Bronchial Drainage System, enables patients with cystic fibrosis to self-administer the technique of high frequency chest compression (HFCC) to assist with mucociliary clearance. We review the literature on HFCC and outline a case study of a patient currently using the ThAIRapy Bronchial Drainage System. While mucociliary clearance and lung function may be enhanced by HFCC therapy, more research is needed to determine its efficacy, cost benefits, and optimum treatment guidelines. Although our initial experience with the patient using this device has been positive, we were unable to accurately evaluate the ThAIRapy Bronchial Drainage System.

  3. Acoustic trapping with a high frequency linear phased array.

    Science.gov (United States)

    Zheng, Fan; Li, Ying; Hsu, Hsiu-Sheng; Liu, Changgeng; Tat Chiu, Chi; Lee, Changyang; Ham Kim, Hyung; Shung, K Kirk

    2012-11-19

    A high frequency ultrasonic phased array is shown to be capable of trapping and translating microparticles precisely and efficiently, made possible due to the fact that the acoustic beam produced by a phased array can be both focused and steered. Acoustic manipulation of microparticles by a phased array is advantageous over a single element transducer since there is no mechanical movement required for the array. Experimental results show that 45 μm diameter polystyrene microspheres can be easily and accurately trapped and moved to desired positions by a 64-element 26 MHz phased array.

  4. Dynamics and sensitivity analysis of high-frequency conduction block

    Science.gov (United States)

    Ackermann, D. Michael; Bhadra, Niloy; Gerges, Meana; Thomas, Peter J.

    2011-10-01

    The local delivery of extracellular high-frequency stimulation (HFS) has been shown to be a fast acting and quickly reversible method of blocking neural conduction and is currently being pursued for several clinical indications. However, the mechanism for this type of nerve block remains unclear. In this study, we investigate two hypotheses: (1) depolarizing currents promote conduction block via inactivation of sodium channels and (2) the gating dynamics of the fast sodium channel are the primary determinate of minimal blocking frequency. Hypothesis 1 was investigated using a combined modeling and experimental study to investigate the effect of depolarizing and hyperpolarizing currents on high-frequency block. The results of the modeling study show that both depolarizing and hyperpolarizing currents play an important role in conduction block and that the conductance to each of three ionic currents increases relative to resting values during HFS. However, depolarizing currents were found to promote the blocking effect, and hyperpolarizing currents were found to diminish the blocking effect. Inward sodium currents were larger than the sum of the outward currents, resulting in a net depolarization of the nodal membrane. Our experimental results support these findings and closely match results from the equivalent modeling scenario: intra-peritoneal administration of the persistent sodium channel blocker ranolazine resulted in an increase in the amplitude of HFS required to produce conduction block in rats, confirming that depolarizing currents promote the conduction block phenomenon. Hypothesis 2 was investigated using a spectral analysis of the channel gating variables in a single-fiber axon model. The results of this study suggested a relationship between the dynamical properties of specific ion channel gating elements and the contributions of corresponding conductances to block onset. Specifically, we show that the dynamics of the fast sodium inactivation gate are

  5. High-Frequency-Induced Cathodic Breakdown during Plasma Electrolytic Oxidation

    Science.gov (United States)

    Nominé, A.; Nominé, A. V.; Braithwaite, N. St. J.; Belmonte, T.; Henrion, G.

    2017-09-01

    The present communication shows the possibility of observing microdischarges under cathodic polarization during plasma electrolytic oxidation at high frequency. Cathodic microdischarges can ignite beyond a threshold frequency found close to 2 kHz. The presence (respectively, absence) of an electrical double layer is put forward to explain how the applied voltage can be screened, which therefore prevents (respectively, promotes) the ignition of a discharge. Interestingly, in the conditions of the present study, the electrical double layer requires between 175 and 260 μ s to form. This situates the expected threshold frequency between 1.92 and 2.86 kHz, which is in good agreement with the value obtained experimentally.

  6. High Frequency Modulation Method for Measuring of Birefringence

    Directory of Open Access Journals (Sweden)

    Šulc M.

    2013-05-01

    Full Text Available A method of optical birefringence measurement is presented. It uses an el ectro-optic modulator for the high frequency modulation of polarization of the laser beam. The developed optical apparatus exhibits high sensitivity. It is able to measure very small birefringence of samples down to 10-3 rad. The accuracy and sensitivity of the method was checked by measurement of calibrated Sol eil – Babi net compensator. Method can be also used for online and accurate measurement of an optical components birefringence. This application was developed with the aim to measure Cotton-Mouton effect in air and nitrogen.

  7. High-frequency electric field amplification in a magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, Aleksandr V [Russian Research Centre ' Kurchatov Institute' , Moscow (Russian Federation)

    2006-11-30

    In the investigation of cyclotron ion heating in systems designed for plasma isotope separation, the high-frequency (HF) electric field amplification effect was found to occur in equilibrium plasma. In the present article this effect is treated as a result of the interaction of the plasma placed in a constant external magnetic field with the HF modes of the vacuum chamber. Consistent elaboration of this approach allowed obtaining a clear interpretation of the HF electric field amplification effect and constructing a simple model of HF field excitation in a plasma column embedded in the external magnetic field. (methodological notes)

  8. Inference from high-frequency data: A subsampling approach

    DEFF Research Database (Denmark)

    Christensen, Kim; Podolskij, Mark; Thamrongrat, Nopporn

    -definite by construction. Moreover, the subsampler is to some extent automatic, as it does not exploit explicit knowledge about the structure of the asymptotic covariance. It therefore tends to adapt to the problem at hand and be robust against misspecification of the noise process. As such, this paper facilitates...... copies of the original statistic based on local stretches of high-frequency data, and then it studies the sampling variation of these. We show that our estimator is consistent both in frictionless markets and models with additive microstructure noise. We derive a rate of convergence for it and are also...

  9. A SYNCHRONIZATION ALGORITHM FOR HF (HIGH FREQUENCY) BROADBAND OFDM SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Yang Lei; Zhang You'ai

    2008-01-01

    In this letter, a kind of associated synchronization algorithm which is suitable for HF (High Frequency) broadband OFDM (Orthogonal Frequency Division Multiplexing) system is presented based on describing and constructing the GMW (Gorden, Mills and Welch) sequence. The algorithm is based on the Schmidl and Minn's symbol timing principle, the constructed GMW sequence is transmitted and disposed, and the synchronization is adjudicated using the correlation of GMW sequence. The simulation result indicates that this algorithm has high performance synchronization ability under the low SNR (Signal to Noise Ratio) at two different kinds of channel models.

  10. High frequency sampling of a continuous-time ARMA process

    CERN Document Server

    Brockwell, Peter J; Klüppelberg, Claudia

    2011-01-01

    Continuous-time autoregressive moving average (CARMA) processes have recently been used widely in the modeling of non-uniformly spaced data and as a tool for dealing with high-frequency data of the form $Y_{n\\Delta}, n=0,1,2,...$, where $\\Delta$ is small and positive. Such data occur in many fields of application, particularly in finance and the study of turbulence. This paper is concerned with the characteristics of the process $(Y_{n\\Delta})_{n\\in\\bbz}$, when $\\Delta$ is small and the underlying continuous-time process $(Y_t)_{t\\in\\bbr}$ is a specified CARMA process.

  11. The wave buoy analogy - estimating high-frequency wave excitations

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2008-01-01

    The paper deals with the wave buoy analogy where a ship is considered as a wave buoy, so that measured ship responses are used as a basis to estimate wave spectra and associated sea state parameters. The study presented follows up on a previous paper, Nielsen [Nielsen UD. Response-based estimation...... processes are carried out in the present paper; however with one of the responses being the relative motion which is a type of response that is sensitive to high-frequency excitations. Based on the present study it is shown that by including the relative motion, the frequency-wise energy distribution can...

  12. Clinical observation of the abnormality of inferior oblique tendon in congenital superior oblique muscle paralytic patients

    Directory of Open Access Journals (Sweden)

    Wei Xiao

    2013-11-01

    Full Text Available AIM: To measure the abnormality of the inferior oblique tendon in patients with congenital superior oblique muscle paralysis.METHODS: In this cross-sectional, self-control designed study, the tensity of the inferior oblique tendon of both the paralytic and nonparalytic eye were measured during the operations in 30 patients who were diagnosed with exotropia(including intermittent exotropia and constant exotropia accompanied with single superior oblique muscle paralysis. The tensity of the tendon was measured as the maximal distance of which the inferior oblique tendon could be lifted from the scleraRESULTS: Inferior oblique had different degrees of thickness, but was tougher and tighter than that of nonparalytic eye. There was a significant difference(PCONCLUSION: The inferior oblique tendon is stronger and less relaxant in the paralytic eyes.

  13. Microwave Imaging under Oblique Illumination

    Directory of Open Access Journals (Sweden)

    Qingyang Meng

    2016-07-01

    Full Text Available Microwave imaging based on inverse scattering problem has been attracting many interests in the microwave society. Among some major technical challenges, the ill-posed, multi-dimensional inversion algorithm and the complicated measurement setup are critical ones that prevent it from practical applications. In this paper, we experimentally investigate the performance of the subspace-based optimization method (SOM for two-dimensional objects when it was applied to a setup designed for oblique incidence. Analytical, simulation, and experimental results show that, for 2D objects, neglecting the cross-polarization scattering will not cause a notable loss of information. Our method can be potentially used in practical imaging applications for 2D-like objects, such as human limbs.

  14. 10 K high frequency pulse tube cryocooler with precooling

    Science.gov (United States)

    Liu, Sixue; Chen, Liubiao; Wu, Xianlin; Zhou, Yuan; Wang, Junjie

    2016-07-01

    A high frequency pulse tube cryocooler with precooling (HPTCP) has been developed and tested to meet the requirement of weak magnetic signals measurement, and the performance characteristics are presented in this article. The HPTCP is a two-stage pulse tube cryocooler with the precooling-stage replaced by liquid nitrogen. Two regenerators completely filled with stainless steel (SS) meshes are used in the cooler. Together with cold inertance tubes and cold gas reservoir, a cold double-inlet configuration is used to control the phase relationship of the HPTCP. The experimental result shows that the cold double-inlet configuration has improved the performance of the cooler obviously. The effects of operation parameters on the performance of the cooler are also studied. With a precooling temperature of 78.5 K, the maximum refrigeration capacity is 0.26 W at 15 K and 0.92 W at 20 K when the input electric power are 174 W and 248 W respectively, and the minimum no-load temperature obtained is 10.3 K, which is a new record on refrigeration temperature for high frequency pulse tube cryocooler reported with SS completely used as regenerative matrix.

  15. Carbon nanotube transistor based high-frequency electronics

    Science.gov (United States)

    Schroter, Michael

    At the nanoscale carbon nanotubes (CNTs) have higher carrier mobility and carrier velocity than most incumbent semiconductors. Thus CNT based field-effect transistors (FETs) are being considered as strong candidates for replacing existing MOSFETs in digital applications. In addition, the predicted high intrinsic transit frequency and the more recent finding of ways to achieve highly linear transfer characteristics have inspired investigations on analog high-frequency (HF) applications. High linearity is extremely valuable for an energy efficient usage of the frequency spectrum, particularly in mobile communications. Compared to digital applications, the much more relaxed constraints for CNT placement and lithography combined with already achieved operating frequencies of at least 10 GHz for fabricated devices make an early entry in the low GHz HF market more feasible than in large-scale digital circuits. Such a market entry would be extremely beneficial for funding the development of production CNTFET based process technology. This talk will provide an overview on the present status and feasibility of HF CNTFET technology will be given from an engineering point of view, including device modeling, experimental results, and existing roadblocks. Carbon nanotube transistor based high-frequency electronics.

  16. A perspective on high-frequency ultrasound for medical applications

    Science.gov (United States)

    Mamou, Jonathan; Aristizába, Orlando; Silverman, Ronald H.; Ketterling, Jeffrey A.

    2010-01-01

    High-frequency ultrasound (HFU, >15 MHz) is a rapidly developing field. HFU is currently used and investigated for ophthalmologic, dermatologic, intravascular, and small-animal imaging. HFU offers a non-invasive means to investigate tissue at the microscopic level with resolutions often better than 100 μm. However, fine resolution is only obtained over the limited depth-of-field (˜1 mm) of single-element spherically-focused transducers typically used for HFU applications. Another limitation is penetration depth because most biological tissues have large attenuation at high frequencies. In this study, two 5-element annular arrays with center frequencies of 17 and 34 MHz were fabricated and methods were developed to obtain images with increased penetration depth and depth-of-field. These methods were used in ophthalmologic and small-animal imaging studies. Improved blood sensitivity was obtained when a phantom mimicking a vitreous hemorrhage was imaged. Central-nervous systems of 12.5-day-old mouse embryos were imaged in utero and in three dimensions for the first time.

  17. High-frequency Pulse-tube Refrigerator for 4 K

    Science.gov (United States)

    Tanaeva, I. A.; Klaasse Bos, C. G.; de Waele, A. T. A. M.

    2006-04-01

    At present pulse-tube refrigerators (PTRs), used for the important temperature region of 4 K, are of the Gifford-McMahon (GM)-type. The main sources of losses in GM-type PTRs are the compressor and the rotary valve. The efficiency of the combination of the compressor and the rotary valve is only about 30%. In addition to that GM-type compressors are heavy and need periodic maintenance. The main goal of this research is to develop a Stirling-type 4-K pulse-tube refrigerator. This implies higher operating frequencies, compared to the usual 1-2 Hz. At higher frequencies a number of properties of a pulse-tube system, such as length-to-diameter ratios of the pulse tubes and the regenerator, volume and configuration of a regenerator material, phase-shift control method, etc., change significantly, and, therefore, require detailed study. The interactions between various parameters of the pulse tube and of the linear compressor are very complicated. Therefore, as a first part of this research, we study the pulse tube at high frequencies, independent of the compressor. We generate high-frequency pressure oscillations, using a GM-type compressor and a special type of rotary valve, which enables us to operate at frequencies up to 20 Hz. Results of this work are described in this contribution.

  18. Design of a high frequency low voltage CMOS operational amplifier

    Directory of Open Access Journals (Sweden)

    Priyanka Kakoty

    2011-03-01

    Full Text Available A method is presented in this paper for the design of a high frequency CMOS operational amplifier (Op-Amp which operates at 3V power supply using tsmc 0.18 micron CMOS technology. The OPAMPdesigned is a two-stage CMOS OPAMP followed by an output buffer. This Operational Transconductance Amplifier (OTA employs a Miller capacitor and is compensated with a current buffer compensation technique. The unique behaviour of the MOS transistors in saturation region not only allows a designer to work at a low voltage, but also at a high frequency. Designing of two-stage op-ampsis a multi-dimensional-optimization problem where optimization of one or more parameters may easily result into degradation of others. The OPAMP is designed to exhibit a unity gain frequency of 2.02GHzand exhibits a gain of 49.02dB with a 60.50 phase margin. As compared to the conventional approach, the proposed compensation method results in a higher unity gain frequency under the same load condition.Design has been carried out in Tanner tools. Simulation results are verified using S-edit and W-edit.

  19. Design of a high frequency low voltage CMOS operational amplifier

    Directory of Open Access Journals (Sweden)

    Priyanka Kakoty

    2011-03-01

    Full Text Available A method is presented in this paper for the design of a high frequency CMOS operational amplifier (Op-Amp which operates at 3V power supply using tsmc 0.18 micron CMOS technology. The OPAMPdesigned is a two-stage CMOS OPAMP followed by an output buffer. This OperationalTransconductance Amplifier (OTA employs a Miller capacitor and is compensated with a current buffercompensation technique. The unique behaviour of the MOS transistors in saturation region not onlyallows a designer to work at a low voltage, but also at a high frequency. Designing of two-stage op-ampsis a multi-dimensional-optimization problem where optimization of one or more parameters may easilyresult into degradation of others. The OPAMP is designed to exhibit a unity gain frequency of 2.02GHzand exhibits a gain of 49.02dB with a 60.50 phase margin. As compared to the conventional approach, theproposed compensation method results in a higher unity gain frequency under the same load condition.Design has been carried out in Tanner tools. Simulation results are verified using S-edit and W-edit.

  20. Efficient Design of Sierpinski Fractal Antenna for High Frequency Applications

    Directory of Open Access Journals (Sweden)

    Rajdeep Singh

    2014-08-01

    Full Text Available A wideband published slot antenna appropriate for wireless code division multiple access (WCDMA and sustaining the international interoperability for microwave access (WiMAX applications is planned here. The antenna is fractal line fed and its construction is based on fractal geometry where the resonance frequency of antenna is dropped by applying iteration methods. Fractal antennas are the most suited for aerospace and UWB applications because of their low profile, light weight and low power handling capacity. They can be designed in a variety of shapes in order to obtain enhanced gain and bandwidth, dual band and circular polarization to even ultra-wideband operation. For the simulation process ANSOFT HFSS (high frequency structure simulator has been used. The effect of antenna dimensions and substrate parameters on the performance of antenna have been discussed. The antenna has been designed using the Arlon substrate with relative permittivity of 1.3 and a substrate of Sierpinski Carpet shaped placed on it. Feed used is the fractal line feed. The designed antenna is a low profile, small size and multiband antenna since it can be operated at different frequencies within the frequency range of 4.3GHz to 11GHz. It includes the frequencies used for wireless WCDMA application and used to receive and transmit a high-frequency signal.

  1. Planck 2013 results. VI. High Frequency Instrument data processing

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J. -P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bowyer, J.W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J. -F.; Catalano, A.; Chamballu, A.; Chary, R. -R.; Chen, X.; Chiang, L. -Y; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J. -M.; Désert, F. -X.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Girard, D.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Herent, O.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, T.R.; Jaffe, A.H.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J. -M.; Lasenby, A.; Laureijs, R.J.; Lawrence, C.R.; Jeune, M. Le; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; MacTavish, C.J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M. -A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Mottet, S.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; North, C.; Noviello, F.; Novikov, D.; Novikov, I.; Orieux, F.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paladini, R.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J. -L.; Rachen, J.P.; Racine, B.; Reach, W.T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sanselme, L.; Santos, D.; Sauvé, A.; Savini, G.; Shellard, E.P.S.; Spencer, L.D.; Starck, J. -L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A. -S.; Sygnet, J. -F.; Tauber, J.A.; Tavagnacco, D.; Techene, S.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; White, S.D.M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per (effective) beam solid angle is respectively, 10, 6, 12 and 39 microKelvin in HFI four lowest frequency channel (100--353 GHz) and 13 and 14 kJy/sr for the 545 and 857 GHz channels. Using the 143 GHz channel as a reference, these two high frequency channels are intercalibrated within 5% and the 353 GHz relative calibration is at the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 < l <2500), are intercalibrated at better than 0.2 %.

  2. Advances in high frequency ultrasound separation of particulates from biomass.

    Science.gov (United States)

    Juliano, Pablo; Augustin, Mary Ann; Xu, Xin-Qing; Mawson, Raymond; Knoerzer, Kai

    2017-03-01

    In recent years the use of high frequency ultrasound standing waves (megasonics) for droplet or cell separation from biomass has emerged beyond the microfluidics scale into the litre to industrial scale applications. The principle for this separation technology relies on the differential positioning of individual droplets or particles across an ultrasonic standing wave field within the reactor and subsequent biomass material predisposition for separation via rapid droplet agglomeration or coalescence into larger entities. Large scale transducers have been characterised with sonochemiluminescence and hydrophones to enable better reactor designs. High frequency enhanced separation technology has been demonstrated at industrial scale for oil recovery in the palm oil industry and at litre scale to assist olive oil, coconut oil and milk fat separation. Other applications include algal cell dewatering and milk fat globule fractionation. Frequency selection depends on the material properties and structure in the biomass mixture. Higher frequencies (1 and 2MHz) have proven preferable for better separation of materials with smaller sized droplets such as milk fat globules. For palm oil and olive oil, separation has been demonstrated within the 400-600kHz region, which has high radical production, without detectable impact on product quality. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  3. Accuracy Potential and Applications of MIDAS Aerial Oblique Camera System

    Science.gov (United States)

    Madani, M.

    2012-07-01

    Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System) is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees) cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels) with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm) and (50 mm/50 mm)) were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance) for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining systematic

  4. Ictal propagation of high frequency activity is recapitulated in interictal recordings: effective connectivity of epileptogenic networks recorded with intracranial EEG.

    Science.gov (United States)

    Korzeniewska, A; Cervenka, M C; Jouny, C C; Perilla, J R; Harezlak, J; Bergey, G K; Franaszczuk, P J; Crone, N E

    2014-11-01

    Seizures are increasingly understood to arise from epileptogenic networks across which ictal activity is propagated and sustained. In patients undergoing invasive monitoring for epilepsy surgery, high frequency oscillations have been observed within the seizure onset zone during both ictal and interictal intervals. We hypothesized that the patterns by which high frequency activity is propagated would help elucidate epileptogenic networks and thereby identify network nodes relevant for surgical planning. Intracranial EEG recordings were analyzed with a multivariate autoregressive modeling technique (short-time direct directed transfer function--SdDTF), based on the concept of Granger causality, to estimate the directionality and intensity of propagation of high frequency activity (70-175 Hz) during ictal and interictal recordings. These analyses revealed prominent divergence and convergence of high frequency activity propagation at sites identified by epileptologists as part of the ictal onset zone. In contrast, relatively little propagation of this activity was observed among the other analyzed sites. This pattern was observed in both subdural and depth electrode recordings of patients with focal ictal onset, but not in patients with a widely distributed ictal onset. In patients with focal ictal onsets, the patterns of propagation recorded during pre-ictal (up to 5 min immediately preceding ictal onset) and interictal (more than 24h before and after seizures) intervals were very similar to those recorded during seizures. The ability to characterize epileptogenic networks from interictal recordings could have important clinical implications for epilepsy surgery planning by reducing the need for prolonged invasive monitoring to record spontaneous seizures.

  5. Microscale capillary wave turbulence excited by high frequency vibration.

    Science.gov (United States)

    Blamey, Jeremy; Yeo, Leslie Y; Friend, James R

    2013-03-19

    Low frequency (O(10 Hz-10 kHz)) vibration excitation of capillary waves has been extensively studied for nearly two centuries. Such waves appear at the excitation frequency or at rational multiples of the excitation frequency through nonlinear coupling as a result of the finite displacement of the wave, most often at one-half the excitation frequency in so-called Faraday waves and twice this frequency in superharmonic waves. Less understood, however, are the dynamics of capillary waves driven by high-frequency vibration (>O(100 kHz)) and small interface length scales, an arrangement ideal for a broad variety of applications, from nebulizers for pulmonary drug delivery to complex nanoparticle synthesis. In the few studies conducted to date, a marked departure from the predictions of classical Faraday wave theory has been shown, with the appearance of broadband capillary wave generation from 100 Hz to the excitation frequency and beyond, without a clear explanation. We show that weak wave turbulence is the dominant mechanism in the behavior of the system, as evident from wave height frequency spectra that closely follow the Rayleigh-Jeans spectral response η ≈ ω(-17/12) as a consequence of a period-halving, weakly turbulent cascade that appears within a 1 mm water drop whether driven by thickness-mode or surface acoustic Rayleigh wave excitation. However, such a cascade is one-way, from low to high frequencies. The mechanism of exciting the cascade with high-frequency acoustic waves is an acoustic streaming-driven turbulent jet in the fluid bulk, driving the fundamental capillary wave resonance through the well-known coupling between bulk flow and surface waves. Unlike capillary waves, turbulent acoustic streaming can exhibit subharmonic cascades from high to low frequencies; here it appears from the excitation frequency all the way to the fundamental modes of the capillary wave at some four orders of magnitude in frequency less than the excitation frequency

  6. High frequency conductivity of hot electrons in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Amekpewu, M., E-mail: mamek219@gmail.com [Department of Applied Physics, University for Development Studies, Navrongo (Ghana); Mensah, S.Y. [Department of Physics, College of Agriculture and Natural Sciences, U.C.C. (Ghana); Musah, R. [Department of Applied Physics, University for Development Studies, Navrongo (Ghana); Mensah, N.G. [Department of Mathematics, College of Agriculture and Natural Sciences, U.C.C. (Ghana); Abukari, S.S.; Dompreh, K.A. [Department of Physics, College of Agriculture and Natural Sciences, U.C.C. (Ghana)

    2016-05-01

    High frequency conductivity of hot electrons in undoped single walled achiral Carbon Nanotubes (CNTs) under the influence of ac–dc driven fields was considered. We investigated semi-classically Boltzmann's transport equation with and without the presence of the hot electrons’ source by deriving the current densities in CNTs. Plots of the normalized current density versus frequency of ac-field revealed an increase in both the minimum and maximum peaks of normalized current density at lower frequencies as a result of a strong injection of hot electrons. The applied ac-field plays a twofold role of suppressing the space-charge instability in CNTs and simultaneously pumping an energy for lower frequency generation and amplification of THz radiations. These have enormous promising applications in very different areas of science and technology.

  7. Planck early results. VI. The High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Bucher, M.; Castex, G.; Colley, J.-M.

    2011-01-01

    We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545...... and 857 GHz with an angular resolution ranging from 9.9 to 4.4′. The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100-217 GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created...... to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project. © ESO, 2011....

  8. Gravitational-wave astronomy: the high-frequency window

    CERN Document Server

    Andersson, N; Andersson, Nils; Kokkotas, Kostas D

    2004-01-01

    This contribution is divided in two parts. The first part provides a text-book level introduction to gravitational radiation. The key concepts required for a discussion of gravitational-wave physics are introduced. In particular, the quadrupole formula is applied to the anticipated ``bread-and-butter'' source for detectors like LIGO, GEO600, EGO and TAMA300: inspiralling compact binaries. The second part provides a brief review of high frequency gravitational waves. In the frequency range above (say) 100Hz, gravitational collapse, rotational instabilities and oscillations of the remnant compact objects are potentially important sources of gravitational waves. Significant and unique information concerning the various stages of collapse, the evolution of protoneutron stars and the details of the supranuclear equation of state of such objects can be drawn from careful study of the gravitational-wave signal. As the amount of exciting physics one may be able to study via the detections of gravitational waves from ...

  9. High frequency techniques an introduction to RF and microwave engineering

    CERN Document Server

    White, Joseph F

    2004-01-01

    A practical guide for today's wireless engineerHigh Frequency Techniques: An Introduction to RF and Microwave Engineering is a clearly written classical circuit and field theory text illustrated with modern computer simulation software. The book's ten chapters cover: *The origins and current uses of wireless transmission *A review of AC analysis, Kirchhoff's laws, RLC elements, skin effect, and introduction to the use of computer simulation software*Resonators, Q definitions, and Q-based impedance matching *Transmission lines, waves, VSWR, reflection phenomena, Fano's reflection bandwidth limits, telegrapher, and impedance transformation equations*Development and in-depth use of the Smith Chart *Matrix algebra with Z, Y, ABCD, S, and T matrix applications*An unusually thorough introduction to electromagnetic field theory, step-by-step development of vector calculus, Maxwell's equations, waveguides, propagation, and antennas*Backward wave, branch line, rat race and Wilkinson couplers, impedance measurements, a...

  10. High Frequency Stochastic Resonance in Periodically Driven Systems

    CERN Document Server

    Dykman, M I

    1993-01-01

    Abstract: High frequency stochastic resonance (SR) phenomena, associated with fluctuational transitions between coexisting periodic attractors, have been investigated experimentally in an electronic model of a single-well Duffing oscillator bistable in a nearly resonant field of frequency $\\omega_F$. It is shown that, with increasing noise intensity, the signal/noise ratio (SNR) for a signal due to a weak trial force of frequency $\\Omega decreases again at higher noise intensities: behaviour similar to that observed previously for conventional (low frequency) SR in systems with static bistable potentials. The stochastic enhancement of the SNR of an additional signal at the mirror-reflected frequency $\\vert Ømega - 2 ømega_F \\vert$ is also observed, in accordance with theoretical predictions. Relationships with phenomena in nonlinear optics are discussed.

  11. High frequency conductivity of hot electrons in carbon nanotubes

    Science.gov (United States)

    Amekpewu, M.; Mensah, S. Y.; Musah, R.; Mensah, N. G.; Abukari, S. S.; Dompreh, K. A.

    2016-05-01

    High frequency conductivity of hot electrons in undoped single walled achiral Carbon Nanotubes (CNTs) under the influence of ac-dc driven fields was considered. We investigated semi-classically Boltzmann's transport equation with and without the presence of the hot electrons' source by deriving the current densities in CNTs. Plots of the normalized current density versus frequency of ac-field revealed an increase in both the minimum and maximum peaks of normalized current density at lower frequencies as a result of a strong injection of hot electrons. The applied ac-field plays a twofold role of suppressing the space-charge instability in CNTs and simultaneously pumping an energy for lower frequency generation and amplification of THz radiations. These have enormous promising applications in very different areas of science and technology.

  12. High frequency acoustic microscopy with Fresnel zoom lens

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The acoustic field distributions and the convergent beams generated by the planar-structure Fresnel zone transducers on solid surface are investigated. Because only 0 and 180 degree phase transducers are used, an imaging system with the Fresnel zoom lens could work at very high frequency, which overcomes the frequency limit of the traditional phased array acoustic imaging system. Simulation results are given to illustrate the acoustic field distributions along the focal axis and the whole plane as well. Based on the principle of scanning of the focus with the change of frequency for the excited signal, an experimental imaging system is also built. Acoustic Fresnel zone transducers are fabricated at center frequency of 400 MHz. Measurements and detections of the known hole flaws at different depths of the fused quartz sample are presented to show that the imaging system with Fresnel zoom lens could move its focus by only changing the frequency of the excited signal.

  13. HIGH FREQUENCY INDUCTION WELDING OF HIGH SILICON STEEL TUBES

    Directory of Open Access Journals (Sweden)

    Ricardo Miranda Alé

    2012-06-01

    Full Text Available High-Si steel is a low cost alternative for the fabrication of tubular structures resistant to atmospheric corrosion. However, the literature has often pointed out that steels presenting a higher Si content and/or a lower Mn/Si ratio have higher susceptibility to defects at the weld bond line during HFIW (High Frequency Induction Welding process, which has been widely used for manufacturing small diameter tubes. In this study the effect of the HFIW conditions on the quality of steel tubes with high-Si content and low Mn/Si ratio is investigated. The quality of welded tubes was determined by flare test and the defects in the bond line were identified by SEM. It has been found that higher welding speeds, V-convergence angles and power input should be applied in welding of high-Si steel, when compared to similar strength C-Mn steel.

  14. MHD waves generated by high-frequency photospheric vortex motions

    Directory of Open Access Journals (Sweden)

    V. Fedun

    2011-06-01

    Full Text Available In this paper, we discuss simulations of MHD wave generation and propagation through a three-dimensional open magnetic flux tube in the lower solar atmosphere. By using self-similar analytical solutions for modelling the magnetic field in Cartesian coordinate system, we have constructed a 3-D magnetohydrostatic configuration which is used as the initial condition for non-linear MHD wave simulations. For a driver we have implemented a high-frequency vortex-type motion at the footpoint region of the open magnetic flux tube. It is found that the implemented swirly source is able to excite different types of wave modes, i.e. sausage, kink and torsional Alfvén modes. Analysing these waves by magneto-seismology tools could provide insight into the magnetic structure of the lower solar atmosphere.

  15. High frequency nano-optomechanical disk resonators in liquids

    CERN Document Server

    Gil-Santos, E; Nguyen, D T; Hease, W; Lemaître, A; Ducci, S; Leo, G; Favero, I

    2015-01-01

    Vibrating nano- and micromechanical resonators have been the subject of research aiming at ultrasensitive mass sensors for mass spectrometry, chemical analysis and biomedical diagnosis. Unfortunately, their merits diminish dramatically in liquids due to dissipative mechanisms like viscosity and acoustic losses. A push towards faster and lighter miniaturized nanodevices would enable improved performances, provided dissipation was controlled and novel techniques were available to efficiently drive and read-out their minute displacement. Here we report on a nano-optomechanical approach to this problem using miniature semiconductor disks. These devices combine mechanical motion at high frequency above the GHz, ultra-low mass of a few picograms, and moderate dissipation in liquids. We show that high-sensitivity optical measurements allow to direct resolve their thermally driven Brownian vibrations, even in the most dissipative liquids. Thanks to this novel technique, we experimentally, numerically and analytically...

  16. Dynamical Structures of High-Frequency Financial Data

    CERN Document Server

    Kim, K; Kim, S Y; Kim, Y; Yoon, S M; Chang, Ki-Ho; Kim, Kyungsik; Kim, Soo Yong; Kim, Yup; Yoon, Seong-Min

    2005-01-01

    We study the dynamical behavior of high-frequency data from the Korean Stock Price Index (KOSPI) using the movement of returns in Korean financial markets. The dynamical behavior for a binarized series of our models is not completely random. The conditional probability is numerically estimated from a return series of KOSPI tick data. Non-trivial probability structures can be constituted from binary time series of autoregressive (AR), logit, and probit models, for which the Akaike Information Criterion shows a minimum value at the 15th order. From our results, we find that the value of the correct match ratio for the AR model is slightly larger than the findings of other models.

  17. High-Frequency Acoustic Sediment Classification in Shallow Water

    CERN Document Server

    Bentrem, F W; Kalcic, M T; Duncan, M E; Bentrem, Frank W.; Sample, John; Kalcic, Maria T.; Duncan, Michael E.

    2002-01-01

    A geoacoustic inversion technique for high-frequency (12 kHz) multibeam sonar data is presented as a means to classify the seafloor sediment in shallow water (40-300 m). The inversion makes use of backscattered data at a variety of grazing angles to estimate mean grain size. The need for sediment type and the large amounts of multibeam data being collected with the Naval Oceanographic Office's Simrad EM 121A systems, have fostered the development of algorithms to process the EM 121A acoustic backscatter into maps of sediment type. The APL-UW (Applied Physics Laboratory at the University of Washington) backscattering model is used with simulated annealing to invert for six geoacoustic parameters. For the inversion, three of the parameters are constrained according to empirical correlations with mean grain size, which is introduced as an unconstrained parameter. The four unconstrained (free) parameters are mean grain size, sediment volume interaction, and two seafloor roughness parameters. Acoustic sediment cla...

  18. High frequency modeling of power transformers. Stresses and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bjerkan, Eilert

    2005-05-15

    In this thesis a reliable, versatile and rigorous method for high frequency power transformer modeling is searched and established. The purpose is to apply this model to sensitivity analysis of FRA (Frequency Response Analysis) which is a quite new diagnostic method for assessing the mechanical integrity of power transformer windings on-site. The method should be versatile in terms of being able to estimate internal and external over voltages and resonances. Another important aspect is that the method chosen is suitable for real transformer geometries. In order to verify the suitability of the model for real transformers, a specific test-object is used. This is a 20MVA transformer, and details are given in chapter 1.4. The high frequency power transformer model is established from geometrical and constructional information from the manufacturer, together with available material characteristics. All circuit parameters in the lumped circuit representation are calculated based on these data. No empirical modifications need to be performed. Comparison shows capability of reasonable accuracy in the range from 10 khz to 1 MHz utilizing a disc-to-disc representation. A compromise between accuracy of model due to discretization and complexity of the model in a turn-to-turn representation is inevitable. The importance of the iron core is emphasized through a comparison of representations with/without the core included. Frequency-dependent phenomena are accurately represented using an isotropic equivalent for windings and core, even with a coarse mesh for the FEM-model. This is achieved through a frequency-dependent complex permeability representation of the materials. This permeability is deduced from an analytical solution of the frequency-dependent magnetic field inside the conductors and the core. The importance of dielectric losses in a transformer model is also assessed. Since published data on the high frequency properties of press board are limited, some initial

  19. High-Frequency Cutoff in Type III Bursts

    Science.gov (United States)

    Stanislavsky, A. A.; Konovalenko, A. A.; Volvach, Ya. S.; Koval, A. A.

    In this article we report about a group of solar bursts with high-frequency cutoff, observed on 19 August of 2012 near 8:23 UT, simultaneously by three different radio telescopes: the Ukrainian decameter radio telescope (8-33 MHz), the French Nancay Decametric Array (10-70 MHz) and the Italian San Vito Solar Observatory of RSTN (25-180 MHz). Morphologically the bursts are very similar to the type III bursts. The solar activity is connected with the emergency of a new group of solar spots on the far side of the Sun with respect to observers on Earth. The solar bursts accompany many moderate flares over eastern limb. The refraction of the behind-limb radio bursts towards the Earth is favorable, if CMEs generate low-density cavities in solar corona.

  20. Electrostatic Instabilities at High Frequency in a Plasma Shock Front

    Institute of Scientific and Technical Information of China (English)

    LV Jian-Hong; HE Yong; HU Xi-Wei

    2007-01-01

    New electrostatic instabilities in the plasma shock front are reported.These instabilities are driven by the electrostatic field which is caused by charge separation and the parameter gradients in a plasma shock front.The linear analysis to the high frequency branch of electrostatic instabilities has been carried out and the dispersion relations are obtained numerically.There are unstable disturbing waves in both the parallel and perpendicular directions of shock propagation.The real frequencies of both unstable waves are similar to the electron electrostatic wave,and the unstable growth rate in the parallel direction is much greater than the one in the perpendicular direction.The dependence of growth rates on the electric field and parameter gradients is also presented.

  1. High-frequency supersonic heating of hydrogen for propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Bonneville, Jacques M.

    1963-03-15

    The possibility of increasing the specific impulse of hydrogen by supersonic heating is shown on the basis of thermodynamics. The application of high-frequency electric fields to heat the gas permits a control over the heating rates in the nozzle, and results in a reduction in energy losses to walls, electrodes, etc. The efficiencies of the various energy transfer processes are considered in some detail. A simple process of expansion and heating is presented. Results of calculations of heat transfer rates to the nozzle wall are given. A consistent set of electron densities and electric fields are also calculated and presented. Some qualitative results of experimental work previously carried out are included. It is concluded that the process should increase the specific impulse of hydrogen appreciably, in a reasonably efficient manner, and that further experimental work is indicated. (auth)

  2. High-frequency thermal processes in harmonic crystals

    CERN Document Server

    Kuzkin, Vitaly A

    2016-01-01

    We consider two high-frequency thermal processes in uniformly heated harmonic crystals relaxing towards equilibrium: (i) equilibration of kinetic and potential energies and (ii) redistribution of energy among spatial directions. Equation describing these processes with deterministic initial conditions is derived. Solution of the equation shows that characteristic time of these processes is of the order of ten periods of atomic vibrations. After that time the system practically reaches the stationary state. It is shown analytically that in harmonic crystals temperature tensor is not isotropic even in the stationary state. As an example, harmonic triangular lattice is considered. Simple formula relating the stationary value of the temperature tensor and initial conditions is derived. The function describing equilibration of kinetic and potential energies is obtained. It is shown that the difference between the energies (Lagrangian) oscillates around zero. Amplitude of these oscillations decays inversely proport...

  3. High-frequency shear-horizontal surface acoustic wave sensor

    Science.gov (United States)

    Branch, Darren W

    2013-05-07

    A Love wave sensor uses a single-phase unidirectional interdigital transducer (IDT) on a piezoelectric substrate for leaky surface acoustic wave generation. The IDT design minimizes propagation losses, bulk wave interferences, provides a highly linear phase response, and eliminates the need for impedance matching. As an example, a high frequency (.about.300-400 MHz) surface acoustic wave (SAW) transducer enables efficient excitation of shear-horizontal waves on 36.degree. Y-cut lithium tantalate (LTO) giving a highly linear phase response (2.8.degree. P-P). The sensor has the ability to detect at the pg/mm.sup.2 level and can perform multi-analyte detection in real-time. The sensor can be used for rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms.

  4. High-frequency underwater plasma discharge application in antibacterial activity

    Science.gov (United States)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.

    2017-03-01

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli ( E. coli) by generating high-frequency, high-voltage, oxygen (O2) injected and hydrogen peroxide (H2O2) added discharge in water was achieved. The effect of H2O2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H2O2 addition with O2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH•, H, and O). Interestingly, the results demonstrated that O2 injected and H2O2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  5. High-frequency underwater plasma discharge application in antibacterial activity

    Science.gov (United States)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.

    2017-03-01

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O2) injected and hydrogen peroxide (H2O2) added discharge in water was achieved. The effect of H2O2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H2O2 addition with O2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH•, H, and O). Interestingly, the results demonstrated that O2 injected and H2O2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  6. High-frequency underwater plasma discharge application in antibacterial activity

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U. [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of); Mongre, R. K.; Jeong, D. K. [Jeju National University, Faculty of Biotechnology (Korea, Republic of); Suresh, R.; Lee, H. J., E-mail: hjlee@jejunu.ac.kr [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of)

    2017-03-15

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O{sub 2}) injected and hydrogen peroxide (H{sub 2}O{sub 2}) added discharge in water was achieved. The effect of H{sub 2}O{sub 2} dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H{sub 2}O{sub 2} addition with O{sub 2} injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH{sup •}, H, and O). Interestingly, the results demonstrated that O{sub 2} injected and H{sub 2}O{sub 2} added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  7. Trans-Ionospheric High Frequency Signal Ray Tracing

    Science.gov (United States)

    Wright, S.; Gillespie, R. J.

    2012-09-01

    All electromagnetic radiation undergoes refraction as it propagates through the atmosphere. Tropospheric refraction is largely governed by interaction of the radiation with bounded electrons; ionospheric refraction is primarily governed by free electron interactions. The latter phenomenon is important for propagation and refraction of High Frequency (HF) through Extremely High Frequency (EHF) signals. The degree to which HF to EHF signals are bent is dependent upon the integrated refractive effect of the ionosphere: a result of the signal's angle of incidence with the boundaries between adjacent ionospheric regions, the magnitude of change in electron density between two regions, as well as the frequency of the signal. In the case of HF signals, the ionosphere may bend the signal so much that it is directed back down towards the Earth, making over-the-horizon HF radio communication possible. Ionospheric refraction is a major challenge for space-based geolocation applications, where the ionosphere is typically the biggest contributor to geolocation error. Accurate geolocation requires an algorithm that accurately reflects the physical process of a signal transiting the ionosphere, and an accurate specification of the ionosphere at the time of the signal transit. Currently implemented solutions are limited by both the algorithm chosen to perform the ray trace and by the accuracy of the ionospheric data used in the calculations. This paper describes a technique for adapting a ray tracing algorithm to run on a General-Purpose Graphics Processing Unit (GPGPU or GPU), and using a physics-based model specifying the ionosphere at the time of signal transit. This technique allows simultaneous geolocation of significantly more signals than an equivalently priced Central Processing Unit (CPU) based system. Additionally, because this technique makes use of the most widely accepted numeric algorithm for ionospheric ray tracing and a timely physics-based model of the ionosphere

  8. High Frequency Plant Regeneration of Musa paradisiaca cv. Karibale Monthan

    Directory of Open Access Journals (Sweden)

    R. Shashi Kumar

    2015-06-01

    Full Text Available High frequency plant regeneration protocol has been standardized from banana cultivar Musa paradisiaca cv. Karibale Monthan, an endemic cultivar of Malnad region of Karnataka. The fruits are used as glomerular protective to solve kidney problems. To minimize the microbial contamination and to promote healthy growth, explants were treated with 70 % absolute alcohol for 6 min, 0.1 % Mercuric chloride for 10 min and 0.2 % for 10 min, 1 % Sodium hypochlorite for 15 min, 0.1 % Cefotaxime for 5 min and 0.05 % Gentamicin for 5 min. The high frequency shoot initiation (93.33 % was recorded at 5 mg/l BAP. The synergetic effect of BAP (4 to 6 mg/l, TDZ (0.1 to 1.2 mg/l and coconut water (0.1 to 0.9 ml/l induced multiple shoot buds and it was optimized at the concentration of 5 mg/l BAP, 0.5 mg/l TDZ and 0.5 ml/l coconut water with 15.90 ± 1.66 frequency of shoots per propagule. Supplementation of 1.0 mg/l IBA induced 5.33 ± 1.21 numbers of roots with a mean root length of 7.50 ± 1.87 roots. The 99% of plantlets with distinct roots and shoots were successfully acclimatized in the green house and transferred to the field to evaluate the agro-morphological variations. The weight of the bunch (kg, number of hands in a bunch, number of fingers in a hand, length of the finger (cm, girth of the finger (cm and girth of the pseudostem (cm exhibited by in vitro plants were higher than the in vivo plants.

  9. High frequency turbidity as a proxy for total phosphorus: application in a mixed land use catchment in Sweden

    Science.gov (United States)

    Lannergård, Emma; Ledesma, José L. J.; Fölster, Jens; Futter, Martyn N.

    2017-04-01

    Surface water eutrophication resulting from excessive phosphorus (P) input is one of the most challenging water issues of today. Total phosphorus (TP) concentrations have high temporal variability, which makes the parameter hard to monitor adequately. We explored the possibility of using high frequency turbidity as a proxy for TP in Sävjaån, a stream in a mixed land use catchment in Sweden. An in situ sensor (YSI 600OMS VS) monitoring turbidity every 10th minute, was situated close to the outlet of Sävjaån during 2014 and 2015. In situ and grab sample turbidity measurements were highly correlated (linear regression, r2=0.90). The maximum turbidity concentration measured by the sensor was at most 13 times higher than the highest concentration from the grab samples. The average turbidity concentration from the two methods was close to similar, as well as the Ecological Quality Ratios (EQR) calculated from the two data sets. The correlation between TP and high frequency turbidity was very high (r2=0.79) and between TSS and turbidity high (r2=0.67). When comparing load estimations from the high frequency data with monthly grab sampling and linear interpolation, the high frequency load was 7 % smaller in 2014 and 17 % larger in 2015. In 2014 the monthly grab sampling caught peaks in TP concentration, which with linear interpolation affected the nearby months and furthermore the yearly load. However, in 2015 peaks in concentration were overlooked when using grab sampling, which gave a larger yearly load when using the high frequency data. Season and flow intensity may affect the relationship between turbidity and TP, however this could not be statistically proven in this study. The proxy relationship could also result in uncertainties tied to unexplained diurnal variations of turbidity, proportion particulate bound P or hysteresis. Uncertainties arising from the use of sensors (e.g. sensor calibration and spatial representation) must as well be recognized. To

  10. Proton Acceleration at Oblique Shocks

    Science.gov (United States)

    Galinsky, V. L.; Shevchenko, V. I.

    2011-06-01

    Acceleration at the shock waves propagating oblique to the magnetic field is studied using a recently developed theoretical/numerical model. The model assumes that resonant hydromagnetic wave-particle interaction is the most important physical mechanism relevant to motion and acceleration of particles as well as to excitation and damping of waves. The treatment of plasma and waves is self-consistent and time dependent. The model uses conservation laws and resonance conditions to find where waves will be generated or damped, and hence particles will be pitch-angle-scattered. The total distribution is included in the model and neither introduction of separate population of seed particles nor some ad hoc escape rate of accelerated particles is needed. Results of the study show agreement with diffusive shock acceleration models in the prediction of power spectra for accelerated particles in the upstream region. However, they also reveal the presence of spectral break in the high-energy part of the spectra. The role of the second-order Fermi-like acceleration at the initial stage of the acceleration is discussed. The test case used in the paper is based on ISEE-3 data collected for the shock of 1978 November 12.

  11. Ionospheric Oblique Incidence Soundings by Satellites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The oblique incidence sweep-frequency ionospheric sounding technique uses the same principle of operation as the vertical incidence sounder. The primary difference...

  12. Oblique interactions of dust density waves

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhelchui [Los Alamos National Laboratory; Li, Yang - Fang [MAX-PLANCK INSTITUTE; Hou, Lujing [MAX-PLANCK INSTITUTE; Jiang, Ke [MAX-PLANCK INSTITUTE; Wu, De - Jin [CHINA; Thomas, Hubertus M [MAX-PLANCK INSTITUTE; Morfill, Gregor E [MAX-PLANCK INSTITUTE

    2010-01-01

    Self-excited dust density waves (DDWs) are studied in a striped electrode device. In addition to the usual perpendicularly (with respect to the electrode) propagating DDWs, which have been frequently observed in dusty plasma experiments on the ground, a low-frequency oblique mode is also observed. This low-frequency oblique DDW has a frequency much lower than the dust plasma frequency and its spontaneous excitation is observed even with a very low dust density. It is found that the low-frequency oblique mode can exist either separately or together with the usual perpendicular mode. In the latter case, a new mode arises as a result of the interactions between the perpendicular and the oblique modes. The experiments show that these three modes satisfy the wave coupling conditions in both the frequencies and the wave-vectors.

  13. High frequency modeling of power transformers. Stresses and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bjerkan, Eilert

    2005-05-15

    In this thesis a reliable, versatile and rigorous method for high frequency power transformer modeling is searched and established. The purpose is to apply this model to sensitivity analysis of FRA (Frequency Response Analysis) which is a quite new diagnostic method for assessing the mechanical integrity of power transformer windings on-site. The method should be versatile in terms of being able to estimate internal and external over voltages and resonances. Another important aspect is that the method chosen is suitable for real transformer geometries. In order to verify the suitability of the model for real transformers, a specific test-object is used. This is a 20MVA transformer, and details are given in chapter 1.4. The high frequency power transformer model is established from geometrical and constructional information from the manufacturer, together with available material characteristics. All circuit parameters in the lumped circuit representation are calculated based on these data. No empirical modifications need to be performed. Comparison shows capability of reasonable accuracy in the range from 10 khz to 1 MHz utilizing a disc-to-disc representation. A compromise between accuracy of model due to discretization and complexity of the model in a turn-to-turn representation is inevitable. The importance of the iron core is emphasized through a comparison of representations with/without the core included. Frequency-dependent phenomena are accurately represented using an isotropic equivalent for windings and core, even with a coarse mesh for the FEM-model. This is achieved through a frequency-dependent complex permeability representation of the materials. This permeability is deduced from an analytical solution of the frequency-dependent magnetic field inside the conductors and the core. The importance of dielectric losses in a transformer model is also assessed. Since published data on the high frequency properties of press board are limited, some initial

  14. Observations of Obliquely Propagating Electron Bernstein Waves

    DEFF Research Database (Denmark)

    Armstrong, R. J.; Juul Rasmussen, Jens; Stenzel, R. L.

    1981-01-01

    Plane electron Bernstein waves propagating obliquely to the magnetic field are investigated. The waves are excited by a plane grid antenna in a large volume magnetoplasma. The observations compare favorably with the predictions of the linear dispersion relation.......Plane electron Bernstein waves propagating obliquely to the magnetic field are investigated. The waves are excited by a plane grid antenna in a large volume magnetoplasma. The observations compare favorably with the predictions of the linear dispersion relation....

  15. Knowledge discovery from high-frequency stream nitrate concentrations: hydrology and biology contributions

    Science.gov (United States)

    Aubert, Alice H.; Thrun, Michael C.; Breuer, Lutz; Ultsch, Alfred

    2016-01-01

    High-frequency, in-situ monitoring provides large environmental datasets. These datasets will likely bring new insights in landscape functioning and process scale understanding. However, tailoring data analysis methods is necessary. Here, we detach our analysis from the usual temporal analysis performed in hydrology to determine if it is possible to infer general rules regarding hydrochemistry from available large datasets. We combined a 2-year in-stream nitrate concentration time series (time resolution of 15 min) with concurrent hydrological, meteorological and soil moisture data. We removed the low-frequency variations through low-pass filtering, which suppressed seasonality. We then analyzed the high-frequency variability component using Pareto Density Estimation, which to our knowledge has not been applied to hydrology. The resulting distribution of nitrate concentrations revealed three normally distributed modes: low, medium and high. Studying the environmental conditions for each mode revealed the main control of nitrate concentration: the saturation state of the riparian zone. We found low nitrate concentrations under conditions of hydrological connectivity and dominant denitrifying biological processes, and we found high nitrate concentrations under hydrological recession conditions and dominant nitrifying biological processes. These results generalize our understanding of hydro-biogeochemical nitrate flux controls and bring useful information to the development of nitrogen process-based models at the landscape scale. PMID:27572284

  16. Knowledge discovery from high-frequency stream nitrate concentrations: hydrology and biology contributions.

    Science.gov (United States)

    Aubert, Alice H; Thrun, Michael C; Breuer, Lutz; Ultsch, Alfred

    2016-08-30

    High-frequency, in-situ monitoring provides large environmental datasets. These datasets will likely bring new insights in landscape functioning and process scale understanding. However, tailoring data analysis methods is necessary. Here, we detach our analysis from the usual temporal analysis performed in hydrology to determine if it is possible to infer general rules regarding hydrochemistry from available large datasets. We combined a 2-year in-stream nitrate concentration time series (time resolution of 15 min) with concurrent hydrological, meteorological and soil moisture data. We removed the low-frequency variations through low-pass filtering, which suppressed seasonality. We then analyzed the high-frequency variability component using Pareto Density Estimation, which to our knowledge has not been applied to hydrology. The resulting distribution of nitrate concentrations revealed three normally distributed modes: low, medium and high. Studying the environmental conditions for each mode revealed the main control of nitrate concentration: the saturation state of the riparian zone. We found low nitrate concentrations under conditions of hydrological connectivity and dominant denitrifying biological processes, and we found high nitrate concentrations under hydrological recession conditions and dominant nitrifying biological processes. These results generalize our understanding of hydro-biogeochemical nitrate flux controls and bring useful information to the development of nitrogen process-based models at the landscape scale.

  17. Speckle interferometric sensor to measure low-amplitude high frequency Ocular Microtremor (OMT)

    Science.gov (United States)

    Ryle, James P.; Al-Kalbani, Mohammed; Gopinathan, Unnikrishnan; Boyle, Gerard; Coakley, Davis; Sheridan, John T.

    2009-08-01

    Ocular microtremor (OMT) is a physiological high frequency (up to 150Hz) low amplitude (150-2500nm) involuntary tremor of the human eye. It is one of the three fixational ocular motions described by Adler and Fliegelman in 1934 as well as microsaccades and drift. Clinical OMT investigations to date have used eye-contacting piezoelectric probes or piezoelectric strain gauges. Before contact can be made, the eye must first be anaesthetised. In some cases, this induces eyelid spasms (blepharospasm) making it impossible to measure OMT. Using the contact probe method, the eye motion is mechanically damped. In addition to this, it is not possible to obtain exact information about the displacement. Results from clinical studies to date have given electrical signal amplitudes from the probe. Recent studies suggest a number of clinical applications for OMT, these include monitoring the depth of anaesthesia of a patient in surgery, prediction of outcome in coma, diagnosis of brainstem death. In addition to this, abnormal OMT frequency content is present in patients with neurological disorders such as Multiple sclerosis and Parkinson's disease. However for ongoing clinical investigations the contact probe method falls short of a non-contact accurate measurement solution. In this paper, we design a compact non contact phase modulating optical fiber speckle interferometer to measure eye motions. We present our calibration results using a calibrated piezoelectric vibration simulator. Digital signal processing is then performed to extract the low amplitude high frequency displacement information.

  18. Towards Efficiency of Oblique Images Orientation

    Science.gov (United States)

    Ostrowski, W.; Bakuła, K.

    2016-03-01

    Many papers on both theoretical aspects of bundle adjustment of oblique images and new operators for detecting tie points on oblique images have been written. However, only a few achievements presented in the literature were practically implemented in commercial software. In consequence often aerial triangulation is performed either for nadir images obtained simultaneously with oblique photos or bundle adjustment for separate images captured in different directions. The aim of this study was to investigate how the orientation of oblique images can be carried out effectively in commercial software based on the structure from motion technology. The main objective of the research was to evaluate the impact of the orientation strategy on both duration of the process and accuracy of photogrammetric 3D products. Two, very popular software: Pix4D and Agisoft Photoscan were tested and two approaches for image blocks were considered. The first approach based only on oblique images collected in four directions and the second approach included nadir images. In this study, blocks for three test areas were analysed. Oblique images were collected with medium-format cameras in maltan cross configuration with registration of GNSS and INS data. As a reference both check points and digital surface models from airborne laser scanning were used.

  19. TOWARDS EFFICIENCY OF OBLIQUE IMAGES ORIENTATION

    Directory of Open Access Journals (Sweden)

    W. Ostrowski

    2016-03-01

    Full Text Available Many papers on both theoretical aspects of bundle adjustment of oblique images and new operators for detecting tie points on oblique images have been written. However, only a few achievements presented in the literature were practically implemented in commercial software. In consequence often aerial triangulation is performed either for nadir images obtained simultaneously with oblique photos or bundle adjustment for separate images captured in different directions. The aim of this study was to investigate how the orientation of oblique images can be carried out effectively in commercial software based on the structure from motion technology. The main objective of the research was to evaluate the impact of the orientation strategy on both duration of the process and accuracy of photogrammetric 3D products. Two, very popular software: Pix4D and Agisoft Photoscan were tested and two approaches for image blocks were considered. The first approach based only on oblique images collected in four directions and the second approach included nadir images. In this study, blocks for three test areas were analysed. Oblique images were collected with medium-format cameras in maltan cross configuration with registration of GNSS and INS data. As a reference both check points and digital surface models from airborne laser scanning were used.

  20. Thermal transport in oblique finned microminichannels

    CERN Document Server

    Fan, Yan; Singh, Pawan Kumar; Lee, Yong Jiun

    2015-01-01

    The main aim of this book is to introduce and give an overview of a novel, easy, and highly effective heat transfer augmentation technique for single-phase micro/minichannel heat sink. The specific objectives of the volume are to: Introduce a novel planar oblique fin microchannel and cylindrical oblique fin minichannel heat sink design using passive heat transfer enhancement techniques  Investigate the thermal transport in both planar and cylindrical oblique fin structures through numerical simulation and systematic experimental studies. Evaluate the feasibility of employing the proposed solution in cooling non-uniform heat fluxes and hotspot suppression Conduct the similarity analysis and parametric study to obtain empirical correlations to evaluate the total heat transfer rate of the oblique fin heat sink Investigate the flow mechanism and optimize the dimensions of cylindrical oblique fin heat sink Investigate the influence of edge effect on flow and temperature uniformity in these oblique fin chan...

  1. Tidal obliquity evolution of potentially habitable planets

    CERN Document Server

    Heller, René; Barnes, Rory

    2011-01-01

    Stellar insolation has been used as the main constraint on a planet's habitability. However, as more Earth-like planets are discovered around low-mass stars (LMSs), a re-examination of the role of tides on the habitability of exoplanets has begun. Those studies have yet to consider the misalignment between a planet's rotational axis and the orbital plane normal, i.e. the planetary obliquity. We apply two equilibrium tide theories to compute the obliquity evolution of terrestrial planets orbiting in the habitable zones around LMSs. The time for the obliquity to decrease from an Earth-like obliquity of 23.5 deg to 5 deg, the 'tilt erosion time', is compared to the traditional insolation habitable zone (IHZ) as a function of semi-major axis, eccentricity, and stellar mass. We also compute tidal heating and equilibrium rotation caused by obliquity tides. The Super-Earth Gl581d and the planet candidate Gl581g are studied as examples for tidal processes. Earth-like obliquities of terrestrial planets in the IHZ arou...

  2. 40 MHz high-frequency ultrafast ultrasound imaging.

    Science.gov (United States)

    Huang, Chih-Chung; Chen, Pei-Yu; Peng, Po-Hsun; Lee, Po-Yang

    2017-06-01

    Ultrafast high-frame-rate ultrasound imaging based on coherent-plane-wave compounding has been developed for many biomedical applications. Most coherent-plane-wave compounding systems typically operate at 3-15 MHz, and the image resolution for this frequency range is not sufficient for visualizing microstructure tissues. Therefore, the purpose of this study was to implement a high-frequency ultrafast ultrasound imaging operating at 40 MHz. The plane-wave compounding imaging and conventional multifocus B-mode imaging were performed using the Field II toolbox of MATLAB in simulation study. In experiments, plane-wave compounding images were obtained from a 256 channel ultrasound research platform with a 40 MHz array transducer. All images were produced by point-spread functions and cyst phantoms. The in vivo experiment was performed from zebrafish. Since high-frequency ultrasound exhibits a lower penetration, chirp excitation was applied to increase the imaging depth in simulation. The simulation results showed that a lateral resolution of up to 66.93 μm and a contrast of up to 56.41 dB were achieved when using 75-angles plane waves in compounding imaging. The experimental results showed that a lateral resolution of up to 74.83 μm and a contrast of up to 44.62 dB were achieved when using 75-angles plane waves in compounding imaging. The dead zone and compounding noise are about 1.2 mm and 2.0 mm in depth for experimental compounding imaging, respectively. The structure of zebrafish heart was observed clearly using plane-wave compounding imaging. The use of fewer than 23 angles for compounding allowed a frame rate higher than 1000 frames per second. However, the compounding imaging exhibits a similar lateral resolution of about 72 μm as the angle of plane wave is higher than 10 angles. This study shows the highest operational frequency for ultrafast high-frame-rate ultrasound imaging. © 2017 American Association of Physicists in Medicine.

  3. The comparison of three high-frequency chest compression devices.

    Science.gov (United States)

    Lee, Yong W; Lee, Jongwon; Warwick, Warren J

    2008-01-01

    High-frequency chest compression (HFCC) is shown to enhance clearance of pulmonary airway secretions. Several HFCC devices have been designed to provide this therapy. Standard equipment consists of an air pulse generator attached by lengths of tubing to an adjustable, inflatable vest/jacket (V/J) garment. In this study, the V/Js were fitted over a mannequin. The three device air pulse generators produced characteristic waveform patterns. The variations in the frequency and pressure setting of devices were consistent with specific device design features. These studies suggest that a better understanding of the effects of different waveform, frequency, and pressure combinations may improve HFCC therapeutic efficacy of three different HFCC machines. The V/J component of HFCC devices delivers the compressive pulses to the chest wall to produce both airflow through and oscillatory effects in the airways. The V/J pressures of three HFCC machines were measured and analyzed to characterize the frequency, pressure, and waveform patterns generated by each of three device models. The dimensions of all V/Js were adjusted to a circumference of approximately 110% of the chest circumference. The V/J pressures were measured, and maximum, minimum, and mean pressure, pulse pressure, and root mean square of three pulse generators were calculated. Jacket pressures ranged between 2 and 34 mmHg. The 103 and 104 models' pulse pressures increased with the increase in HFCC frequency at constant dial pressure. With the ICS the pulse pressure decreased when the frequency increased. The waveforms of models 103 and 104 were symmetric sine wave and asymmetric sine wave patterns, respectively. The ICS had a triangular waveform. At 20 Hz, both the 103 and 104 were symmetric sine waveform but the ICS remained triangular. Maximum crest factors emerged in low-frequency and high-pressure settings for the ICS and in the high-frequency and low-pressure settings for models 103 and 104. Recognizing the

  4. Mitigation of impedance changes due to electroporation therapy using bursts of high-frequency bipolar pulses.

    Science.gov (United States)

    Bhonsle, Suyashree P; Arena, Christopher B; Sweeney, Daniel C; Davalos, Rafael V

    2015-01-01

    For electroporation-based therapies, accurate modeling of the electric field distribution within the target tissue is important for predicting the treatment volume. In response to conventional, unipolar pulses, the electrical impedance of a tissue varies as a function of the local electric field, leading to a redistribution of the field. These dynamic impedance changes, which depend on the tissue type and the applied electric field, need to be quantified a priori, making mathematical modeling complicated. Here, it is shown that the impedance changes during high-frequency, bipolar electroporation therapy are reduced, and the electric field distribution can be approximated using the analytical solution to Laplace's equation that is valid for a homogeneous medium of constant conductivity. Two methods were used to examine the agreement between the analytical solution to Laplace's equation and the electric fields generated by 100 µs unipolar pulses and bursts of 1 µs bipolar pulses. First, pulses were applied to potato tuber tissue while an infrared camera was used to monitor the temperature distribution in real-time as a corollary to the electric field distribution. The analytical solution was overlaid on the thermal images for a qualitative assessment of the electric fields. Second, potato ablations were performed and the lesion size was measured along the x- and y-axes. These values were compared to the analytical solution to quantify its ability to predict treatment outcomes. To analyze the dynamic impedance changes due to electroporation at different frequencies, electrical impedance measurements (1 Hz to 1 MHz) were made before and after the treatment of potato tissue. For high-frequency bipolar burst treatment, the thermal images closely mirrored the constant electric field contours. The potato tissue lesions differed from the analytical solution by 39.7 ± 1.3 % (x-axis) and 6.87 ± 6.26 % (y-axis) for conventional unipolar pulses, and 15.46 ± 1.37 % (x

  5. Theory of High Frequency Rectification by Silicon Crystals

    Science.gov (United States)

    Bethe, H. A.

    1942-10-29

    The excellent performance of British "red dot" crystals is explained as due to the knife edge contact against a polished surface. High frequency rectification depends critically on the capacity of the rectifying boundary layer of the crystal, C. For high conversion efficiency, the product of this capacity and of the "forward" (bulk) resistance R {sub b} of the crystal must be small. For a knife edge, this product depends primarily on the breadth of the knife edge and very little upon its length. The contact can therefore have a rather large area which prevents burn-out. For a wavelength of 10 cm. the computations show that the breadth of the knife edge should be less than about 10 {sup -3} cm. For a point contact the radius must be less than 1.5 x 10 {sup -3} cm. and the resulting small area is conducive to burn-out. The effect of "tapping" is probably to reduce the area of contact. (auth)

  6. Refraction of high frequency noise in an arbitrary jet flow

    Science.gov (United States)

    Khavaran, Abbas; Krejsa, Eugene A.

    1994-01-01

    Refraction of high frequency noise by mean flow gradients in a jet is studied using the ray-tracing methods of geometrical acoustics. Both the two-dimensional (2D) and three-dimensional (3D) formulations are considered. In the former case, the mean flow is assumed parallel and the governing propagation equations are described by a system of four first order ordinary differential equations. The 3D formulation, on the other hand, accounts for the jet spreading as well as the axial flow development. In this case, a system of six first order differential equations are solved to trace a ray from its source location to an observer in the far field. For subsonic jets with a small spreading angle both methods lead to similar results outside the zone of silence. However, with increasing jet speed the two prediction models diverge to the point where the parallel flow assumption is no longer justified. The Doppler factor of supersonic jets as influenced by the refraction effects is discussed and compared with the conventional modified Doppler factor.

  7. Ultra high frequency induction welding of powder metal compacts

    Directory of Open Access Journals (Sweden)

    Çavdar, Uǧur

    2014-06-01

    Full Text Available The application of the iron based Powder Metal (PM compacts in Ultra High Frequency Induction Welding (UHFIW were reviewed. These PM compacts are used to produce cogs. This study investigates the methods of joining PM materials enforceability with UHFIW in the industry application. Maximum stress and maximum strain of welded PM compacts were determined by three point bending and strength tests. Microhardness and microstructure of induction welded compacts were determined.Soldadura por inducción de ultra alta frecuencia de polvos de metal compactados. Se ha realizado un estudio de la aplicación de polvos de metal (PM de base hierro compactados por soldadura por inducción de ultra alta frecuencia (UHFIW. Estos polvos de metal compactados se utilizan para producir engranajes. Este estudio investiga los métodos de uni.n de los materiales de PM con UHFIW en su aplicación en la industria. La máxima tensión y la máxima deformación de los polvos de metal compactados soldados fueron determinadas por flexión en tres puntos y prueba de resistencia. Se determinó la microdureza y la microestructura de los polvos compactados por soldadura por inducción.

  8. High-frequency chest compression: a summary of the literature.

    Science.gov (United States)

    Dosman, Cara F; Jones, Richard L

    2005-01-01

    The purpose of the present literature summary is to describe high-frequency chest compression (HFCC), summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  9. Improving NASICON Sinterability through Crystallization under High Frequency Electrical Fields

    Directory of Open Access Journals (Sweden)

    Ilya eLisenker

    2016-03-01

    Full Text Available The effect of high frequency (HF electric fields on the crystallization and sintering rates of a lithium aluminum germanium phosphate (LAGP ion conducting ceramic was investigated. LAGP with the nominal composition Li1.5Al0.5Ge1.5(PO43 was crystallized and sintered, both conventionally and under effect of electrical field. Electrical field application, of 300V/cm at 1MHz, produced up to a 40% improvement in sintering rate of LAGP that was crystallized and sintered under the HF field. Heat sink effect of the electrodes appears to arrest thermal runaway and subsequent flash behavior. Sintered pellets were characterized using XRD, SEM, TEM and EIS to compare conventionally and field sintered processes. The as-sintered structure appears largely unaffected by the field as the sintering curves tend to converge beyond initial stages of sintering. Differences in densities and microstructure after 1 hour of sintering were minor with measured sintering strains of 31% vs. 26% with and without field, respectively . Ionic conductivity of the sintered pellets was evaluated and no deterioration due to the use of HF field was noted, though capacitance of grain boundaries due to secondary phases was significantly increased.

  10. High frequency of BRAF V600E mutations in ameloblastoma.

    Science.gov (United States)

    Kurppa, Kari J; Catón, Javier; Morgan, Peter R; Ristimäki, Ari; Ruhin, Blandine; Kellokoski, Jari; Elenius, Klaus; Heikinheimo, Kristiina

    2014-04-01

    Ameloblastoma is a benign but locally infiltrative odontogenic neoplasm. Although ameloblastomas rarely metastasise, recurrences together with radical surgery often result in facial deformity and significant morbidity. Development of non-invasive therapies has been precluded by a lack of understanding of the molecular background of ameloblastoma pathogenesis. When addressing the role of ERBB receptors as potential new targets for ameloblastoma, we discovered significant EGFR over-expression in clinical samples using real-time RT-PCR, but observed variable sensitivity of novel primary ameloblastoma cells to EGFR-targeted drugs in vitro. In the quest for mutations downstream of EGFR that could explain this apparent discrepancy, Sanger sequencing revealed an oncogenic BRAF V600E mutation in the cell line resistant to EGFR inhibition. Further analysis of the clinical samples by Sanger sequencing and BRAF V600E-specific immunohistochemistry demonstrated a high frequency of BRAF V600E mutations (15 of 24 samples, 63%). These data provide novel insight into the poorly understood molecular pathogenesis of ameloblastoma and offer a rationale to test drugs targeting EGFR or mutant BRAF as novel therapies for ameloblastoma. © 2013 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of Pathological Society of Great Britain and Ireland.

  11. High frequency acoustic microscopy with Fresnel zoom lens

    Institute of Scientific and Technical Information of China (English)

    QIAO DongHai; LI ShunZhou; WANG ChengHao

    2007-01-01

    The acoustic field distributions and the convergent beams generated by the planar-structure Fresnel zone transducers on solid surface are investigated.Because only 0 and 180 degree phase transducers are used,an imaging system with the Fresnel zoom lens could work at very high frequency,which overcomes the frequency limit of the traditional phased array acoustic imaging system.Simulation results are given to illustrate the acoustic field distributions along the focal axis and the whole plane as well.Based on the principle of scanning of the focus with the change of frequency for the excited signal,an experimental imaging system is also built.Acoustic Fresnel zone transducers are fabricated at center frequency of 400 MHz.Measurements and detections of the known hole flaws at different depths of the fused quartz sample are presented to show that the imaging system with Fresnel zoom lens could move its focus by only changing the frequency of the excited signal.

  12. Three-Dimensional Electromagnetic High Frequency Axisymmetric Cavity Scars.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Jorgenson, Roy Eberhardt

    2014-10-01

    This report examines the localization of high frequency electromagnetic fi elds in three-dimensional axisymmetric cavities along periodic paths between opposing sides of the cavity. The cases where these orbits lead to unstable localized modes are known as scars. This report treats both the case where the opposing sides, or mirrors, are convex, where there are no interior foci, and the case where they are concave, leading to interior foci. The scalar problem is treated fi rst but the approximations required to treat the vector fi eld components are also examined. Particular att ention is focused on the normalization through the electromagnetic energy theorem. Both projections of the fi eld along the scarred orbit as well as point statistics are examined. Statistical comparisons are m ade with a numerical calculation of the scars run with an axisymmetric simulation. This axisymmetric cas eformstheoppositeextreme(wherethetwomirror radii at each end of the ray orbit are equal) from the two -dimensional solution examined previously (where one mirror radius is vastly di ff erent from the other). The enhancement of the fi eldontheorbitaxiscanbe larger here than in the two-dimensional case. Intentionally Left Blank

  13. Why high-frequency pulse tubes can be tipped

    Energy Technology Data Exchange (ETDEWEB)

    Swift, Gregory W092710 [Los Alamos National Laboratory; Backhaus, Scott N [Los Alamos National Laboratory

    2010-01-01

    The typical low-frequency pulse-tube refrigerator loses significant cooling power when it is tipped with the pulse tube's cold end above its hot end, because natural convection in the pulse tube loads the cold heat exchanger. Yet most high-frequency pulse-tube refrigerators work well in any orientation with respect to gravity. In such a refrigerator, natural convection is suppressed by sufficiently fast velocity oscil1ations, via a nonlinear hydrodynamic effect that tends to align the density gradients in the pulse tube parallel to the oscillation direction. Since gravity's tendency to cause convection is only linear in the pulse tube's end-to-end temperature difference while the oscillation's tendency to align density gradients with oscillating velocity is nonlinear, it is easiest to suppress convection when the end-to-end temperature difference is largest. Simple experiments demonstrate this temperature dependence, the strong dependence on the oscillating velocity, and little dependence on the magnitude or phase of the oscillating pressure. In some circumstances in this apparatus, the suppression of convection is a hysteretic function of oscillating velocity. In some other circumstances, a time-dependent convective state seems more difficult to suppress.

  14. Extremely high-frequency micro-Doppler measurements of humans

    Science.gov (United States)

    Hedden, Abigail S.; Silvious, Jerry L.; Dietlein, Charles R.; Green, Jeremy A.; Wikner, David A.

    2014-05-01

    The development of sensors that are capable of penetrating smoke, dust, fog, clouds, and rain is critical for maintaining situational awareness in degraded visual environments and for providing support to the Warfighter. Atmospheric penetration properties, the ability to form high-resolution imagery with modest apertures, and available source power make the extremely high-frequency (EHF) portion of the spectrum promising for the development of radio frequency (RF) sensors capable of penetrating visual obscurants. Comprehensive phenomenology studies including polarization and backscatter properties of relevant targets are lacking at these frequencies. The Army Research Laboratory (ARL) is developing a fully-polarimetric frequency-modulated continuous-wave (FMCW) instrumentation radar to explore polarization and backscatter properties of in-situ rain, scattering from natural and man-made surfaces, and the radar cross section and micro-Doppler signatures of humans at EHF frequencies, specifically, around the 220 GHz atmospheric window. This work presents an overview of the design and construction of the radar system, hardware performance, data acquisition software, and initial results including an analysis of human micro-Doppler signatures.

  15. Planck pre-launch status: High Frequency Instrument polarization calibration

    CERN Document Server

    Rosset, C; Ponthieu, N; Ade, P; Catalano, A; Conversi, L; Couchot, F; Crill, B P; Désert, F -X; Ganga, K; Giard, M; Giraud-Héraud, Y; Haïssinski, J; Henrot-Versillé, S; Holmes, W; Jones, W C; Lamarre, J -M; Lange, A; Leroy, C; Macías-Pérez, J; Maffei, B; de Marcillac, P; Miville-Deschênes, M -A; Montier, L; Noviello, F; Pajot, F; Perdereau, O; Piacentini, F; Piat, M; Plaszczynski, S; Pointecouteau, E; Puget, J -L; Ristorcelli, I; Savini, G; Sudiwala, R; Veneziani, M; Yvon, D

    2010-01-01

    The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization ($\\Delta P/T_{\\tiny cmb} \\sim 4\\cdot 10^{-6}$) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the Cosmic Microwave Background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the $E$-mode spectrum (up to $\\ell \\sim 1500$) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of...

  16. High-frequency acoustic for nanostructure wetting characterization.

    Science.gov (United States)

    Li, Sizhe; Lamant, Sebastien; Carlier, Julien; Toubal, Malika; Campistron, Pierre; Xu, Xiumei; Vereecke, Guy; Senez, Vincent; Thomy, Vincent; Nongaillard, Bertrand

    2014-07-01

    Nanostructure wetting is a key problem when developing superhydrophobic surfaces. Conventional methods do not allow us to draw conclusions about the partial or complete wetting of structures on the nanoscale. Moreover, advanced techniques are not always compatible with an in situ, real time, multiscale (from macro to nanoscale) characterization. A high-frequency (1 GHz) acoustic method is used for the first time to characterize locally partial wetting and the wetting transition between nanostructures according to the surface tension of liquids (the variation is obtained by ethanol concentration modification). We can see that this method is extremely sensitive both to the level of liquid imbibition and to the impalement dynamic. We thus demonstrate the possibility to evaluate the critical surface tension of a liquid for which total wetting occurs according to the aspect ratio of the nanostructures. We also manage to identify intermediate states according to the height of the nanotexturation. Finally, our measurements revealed that the drop impalement depending on the surface tension of the liquid also depends on the aspect ratio of the nanostructures. We do believe that our method may lead to new insights into nanoscale wetting characterization by accessing the dynamic mapping of the liquid imbibition under the droplet.

  17. High-frequency ultrasonic imaging of thickly sliced specimens

    Science.gov (United States)

    Miyasaka, Chiaki; Tittmann, Bernhard R.; Chandraratna, Premindra A. N.

    2003-07-01

    It has been reported that a mechanical scanning reflection acoustic microscope (hereinafter called simply "SAM"), using high frequency ultrasonic tone-burst waves, can form a horizontal cross-sectional image (i.e., c-scan image) showing a highly resolved cellular structure of biological tissue. However, the tissue prepared for the SAM has been mostly a thinly sectioned specimen. In this study, the SAM images of specimens thickly sectioned from the tissue were analyzed. Optical and scanning acoustic microscopies were used to evaluate tissues of human small intestine and esophagus. For preparing thin specimens, the tissue was embedded in paraffin, and substantially sectioned at 5-10μm by the microtome. For optical microscopy, the tissue was stained with hematoxylin and eosin, and affixed onto glass substrates. For scanning acoustic microscopy, two types of specimens were prepared: thinly sectioned specimens affixed on the glass substrate, wherein the specimens were deparaffinized in xylene, but not stained, and thickely sectioned specimens. Images of the thick specimens obtained with frequency at 200 MHz revealed cellular structures. The morphology was very similar to that seen in the thinly sectioned specimens with optical and scanning acoustic microscopy. In addition, scanning electron microscopy was used to compare the images of biological tissue. An acoustic lens with frequency at 200 MHz permitted the imaging of surface and/or subsurface of microstructures in the thick sections of small intestine and esophagus.

  18. High-frequency oscillations and mesial temporal lobe epilepsy.

    Science.gov (United States)

    Lévesque, Maxime; Shiri, Zahra; Chen, Li-Yuan; Avoli, Massimo

    2017-01-20

    The interest of epileptologists has recently shifted from the macroscopic analysis of interictal spikes and seizures to the microscopic analysis of short events in the EEG that are not visible to the naked eye but are observed once the signal has been filtered in specific frequency bands. With the use of new technologies that allow multichannel recordings at high sampling rates and the development of computer algorithms that permit the automated analysis of extensive amounts of data, it is now possible to extract high-frequency oscillations (HFOs) between 80 and 500Hz from the EEG; HFOs have been further categorised as ripples (80-200Hz) and fast ripples (250-500Hz). Within the context of epileptic disorders, HFOs should reflect the pathological activity of neural networks that sustain seizure generation, and could serve as biomarkers of epileptogenesis and ictogenesis. We review here the presumptive cellular mechanisms of ripples and fast ripples in mesial temporal lobe epilepsy. We also focus on recent findings regarding the occurrence of HFOs during epileptiform activity observed in in vitro models of epileptiform synchronization, in in vivo models of mesial temporal lobe epilepsy and in epileptic patients. Finally, we address the effects of anti-epileptic drugs on HFOs and raise some questions and issues related to the definition of HFOs.

  19. Algorithmic and high-frequency trading in Borsa Istanbul

    Directory of Open Access Journals (Sweden)

    Oguz Ersan

    2016-12-01

    Full Text Available This paper investigates the levels of algorithmic trading (AT and high-frequency trading (HFT in an emerging market, Borsa Istanbul (BIST, utilizing a dataset of 354 trading days between January 2013 and May 2014. We find an upward trend in AT by using common proxies: number of messages per minute and algo_trad of Hendershott et al. (2011. Mean algo_trad for BIST 100 index constituents varies between −18 and −13 which is parallel to 2003–2005 levels of NASDAQ large cap stocks. Initially, we measure HFT involvement by detecting linked messages as in the way proposed in Hasbrouck and Saar (2013. Next, we propose an extended HFT measure which captures various HFT strategies. This measure attributes approximately 6% of the orders to HFT. HFT involvement is higher in large orders (11.96%, in orders submitted by portfolio/fund management firms (10.40%, after improvement of BIST's order submission platform and tick size reduction for certain stocks.

  20. Low temperature high frequency coaxial pulse tube for space application

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Aurelia; Charles, Ivan; Rousset, Bernard; Duval, Jean-Marc [SBT, UMR-E CEA / UJF-Grenoble 1, INAC, 17, rue des Martyrs, Grenoble, F-38054 (France); Daniel, Christophe [CNES, 18, avenue Edouard Belin, Toulouse, F-31401 (France)

    2014-01-29

    The 4K stage is a critical step for space missions. The Hershel mission is using a helium bath, which is consumed day by day (after depletion, the space mission is over) while the Plank mission is equipped with one He4 Joule-Thomson cooler. Cryogenic chain without helium bath is a challenge for space missions and 4.2K Pulse-Tube working at high frequency (around 30Hz) is one option to take it up. A low temperature Pulse-Tube would be suitable for the ESA space mission EChO (Exoplanet Characterisation Observatory, expected launch in 2022), which requires around 30mW cooling power at 6K; and for the ESA space mission ATHENA (Advanced Telescope for High ENergy Astrophysics), to pre-cool the sub-kelvin cooler (few hundreds of mW at 15K). The test bench described in this paper combines a Gifford-McMahon with a coaxial Pulse-Tube. A thermal link is joining the intercept of the Pulse-Tube and the second stage of the Gifford-McMahon. This intercept is a separator between the hot and the cold regenerators of the Pulse-Tube. The work has been focused on the cold part of this cold finger. Coupled with an active phase shifter, this Pulse-Tube has been tested and optimized and temperatures as low as 6K have been obtained at 30Hz with an intercept temperature at 20K.

  1. High-frequency (1000 Hz) tympanometry in normal neonates.

    Science.gov (United States)

    Kei, Joseph; Allison-Levick, Julie; Dockray, Jacqueline; Harrys, Rachel; Kirkegard, Christina; Wong, Janet; Maurer, Marion; Hegarty, Jayne; Young, June; Tudehope, David

    2003-01-01

    The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2%), a flat-sloping tympanogram in 14 ears (5.7%), a double-peaked tympanogram in 3 ears (1.2%) and other unusual shapes in 2 ears (0.8%). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates.

  2. High-Frequency Chest Compression: A Summary of the Literature

    Directory of Open Access Journals (Sweden)

    Cara F Dosman

    2005-01-01

    Full Text Available The purpose of the present literature summary is to describe high-frequency chest compression (HFCC, summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  3. High-frequency ultrasonic arrays for ocular imaging

    Science.gov (United States)

    Jaeger, M. D.; Kline-Schoder, R. J.; Douville, G. M.; Gagne, J. R.; Morrison, K. T.; Audette, W. E.; Kynor, D. B.

    2007-03-01

    High-resolution ultrasound imaging of the anterior portion of the eye has been shown to provide important information for sizing of intraocular lens implants, diagnosis of pathological conditions, and creation of detailed maps of corneal topography to guide refractive surgery. Current ultrasound imaging systems rely on mechanical scanning of a single acoustic element over the surface of the eye to create the three-dimensional information needed by clinicians. This mechanical scanning process is time-consuming and subject to errors caused by eye movement during the scanning period. This paper describes development of linear ultrasound imaging arrays intended to increase the speed of image acquisition and reduce problems associated with ocular motion. The arrays consist of a linear arrangement of high-frequency transducer elements designed to operate in the 50 - 75 MHz frequency range. The arrays are produced using single-crystal lithium niobate piezoelectric material, thin film electrodes, and epoxy-based acoustic layers. The array elements have been used to image steel test structures and bovine cornea.

  4. High frequency microseismic noise as possible earthquake precursor

    Directory of Open Access Journals (Sweden)

    Ivica Sović

    2013-08-01

    Full Text Available Before an earthquake occurs, microseismic noise in high frequency (HF range, i.e. 2-25 Hz, is being generated during preparation process. These signals change the microseismic noise and, consequently, the spectrum of microseismic noise. Time variation of spectra recorded at the same seismological station could imply the change of the state of noise source. We propose the image moment analysis approach to objectively compare microseismic noise spectra. The result could be used for earthquake precursor identification. Expected spectra change is in HF range, so the analysis has been limited to the shallow tectonic earthquakes with epicenters close, up to 15 km, the seismological stations. The method has been tested post festum using four earthquakes in Dinarides which satisfied condition for epicentral distance. The spectra were calculated for noise recorded in time intervals of 10 days before and 6 to 10 days after the earthquakes. Affine moment invariants were calculated for noise spectra which were treated as the input objects. Spectra of the first five days in the series were referent spectra. The classification parameters were Euclidean distances between referent spectra and the spectra for all days in the series, including referent ones. The results have shown that the spectra of the microseismic noise become noticeably different than the other spectra in time intervals one or two days before an earthquake.

  5. Protection circuits for very high frequency ultrasound systems.

    Science.gov (United States)

    Choi, Hojong; Shung, K Kirk

    2014-04-01

    The purpose of protection circuits in ultrasound applications is to block noise signals from the transmitter from reaching the transducer and also to prevent unwanted high voltage signals from reaching the receiver. The protection circuit using a resistor and diode pair is widely used due to its simple architecture, however, it may not be suitable for very high frequency (VHF) ultrasound transducer applications (>100 MHz) because of its limited bandwidth. Therefore, a protection circuit using MOSFET devices with unique structure is proposed in this paper. The performance of the designed protection circuit was compared with that of other traditional protection schemes. The performance characteristics measured were the insertion loss (IL), total harmonic distortion (THD) and transient response time (TRT). The new protection scheme offers the lowest IL (-1.0 dB), THD (-69.8 dB) and TRT (78 ns) at 120 MHz. The pulse-echo response using a 120 MHz LiNbO3 transducer with each protection circuit was measured to validate the feasibility of the protection circuits in VHF ultrasound applications. The sensitivity and bandwidth of the transducer using the new protection circuit improved by 252.1 and 50.9 %, respectively with respect to the protection circuit using a resistor and diode pair. These results demonstrated that the new protection circuit design minimizes the IL, THD and TRT for VHF ultrasound transducer applications.

  6. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  7. Planck early results. VI. The High Frequency Instrument data processing

    Science.gov (United States)

    Planck HFI Core Team; Ade, P. A. R.; Aghanim, N.; Ansari, R.; Arnaud, M.; Ashdown, M.; Aumont, J.; Banday, A. J.; Bartelmann, M.; Bartlett, J. G.; Battaner, E.; Benabed, K.; Benoît, A.; Bernard, J.-P.; Bersanelli, M.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bradshaw, T.; Bucher, M.; Cardoso, J.-F.; Castex, G.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chen, X.; Chiang, C.; Church, S.; Clements, D. L.; Colley, J.-M.; Colombi, S.; Couchot, F.; Coulais, A.; Cressiot, C.; Crill, B. P.; Crook, M.; de Bernardis, P.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Dolag, K.; Dole, H.; Doré, O.; Douspis, M.; Dunkley, J.; Efstathiou, G.; Filliard, C.; Forni, O.; Fosalba, P.; Ganga, K.; Giard, M.; Girard, D.; Giraud-Héraud, Y.; Gispert, R.; Górski, K. M.; Gratton, S.; Griffin, M.; Guyot, G.; Haissinski, J.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Hildebrandt, S. R.; Hills, R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Huffenberger, K. M.; Jaffe, A. H.; Jones, W. C.; Kaplan, J.; Kneissl, R.; Knox, L.; Kunz, M.; Lagache, G.; Lamarre, J.-M.; Lange, A. E.; Lasenby, A.; Lavabre, A.; Lawrence, C. R.; Le Jeune, M.; Leroy, C.; Lesgourgues, J.; Macías-Pérez, J. F.; MacTavish, C. J.; Maffei, B.; Mandolesi, N.; Mann, R.; Marleau, F.; Marshall, D. J.; Masi, S.; Matsumura, T.; McAuley, I.; McGehee, P.; Melin, J.-B.; Mercier, C.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Mortlock, D.; Murphy, A.; Nati, F.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; North, C.; Noviello, F.; Novikov, D.; Osborne, S.; Pajot, F.; Patanchon, G.; Peacocke, T.; Pearson, T. J.; Perdereau, O.; Perotto, L.; Piacentini, F.; Piat, M.; Plaszczynski, S.; Pointecouteau, E.; Ponthieu, N.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Reach, W. T.; Remazeilles, M.; Renault, C.; Riazuelo, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Saha, R.; Santos, D.; Savini, G.; Schaefer, B. M.; Shellard, P.; Spencer, L.; Starck, J.-L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sutton, D.; Sygnet, J.-F.; Tauber, J. A.; Thum, C.; Torre, J.-P.; Touze, F.; Tristram, M.; van Leeuwen, F.; Vibert, L.; Vibert, D.; Wade, L. A.; Wandelt, B. D.; White, S. D. M.; Wiesemeyer, H.; Woodcraft, A.; Yurchenko, V.; Yvon, D.; Zacchei, A.

    2011-12-01

    We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857 GHz with an angular resolution ranging from 9.9 to 4.4'. The white noise level is around 1.5 μK degree or less in the 3 main CMB channels (100-217 GHz). The photometric accuracy is better than 2% at frequencies between 100 and 353 GHz and around 7% at the two highest frequencies. The maps created by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project. Corresponding author: F. R. Bouchet, e-mail: bouchet@iap.fr

  8. Planck Early Results: The High Frequency Instrument data processing

    CERN Document Server

    Ade, P A R; Ansari, R; Arnaud, M; Ashdown, M; Aumont, J; Banday, A J; Bartelmann, M; Bartlett, J G; Battaner, E; Benabed, K; Benoît, A; Bernard, J -P; Bersanelli, M; Bock, J J; Bond, J R; Borrill, J; Bouchet, F R; Boulanger, F; Bradshaw, T; Bucher, M; Cardoso, J -F; Castex, G; Catalano, A; Challinor, A; Chamballu, A; Chary, R -R; Chen, X; Chiang, C; Church, S; Clements, D L; Colley, J -M; Colombi, S; Couchot, F; Coulais, A; Cressiot, C; Crill, B P; Crook, M; de Bernardis, P; Delabrouille, J; Delouis, J -M; Désert, F -X; Dolag, K; Dole, H; Doré, O; Douspis, M; Dunkley, J; Efstathiou, G; Filliard, C; Forni, O; Fosalba, P; Ganga, K; Giard, M; Girard, D; Giraud-Héraud, Y; Gispert, R; Górski, K M; Gratton, S; Griffin, M; Guyot, G; Haissinski, J; Harrison, D; Helou, G; Henrot-Versillé, S; Hernández-Monteagudo, C; Hildebrandt, S R; Hills, R; Hivon, E; Hobson, M; Holmes, W A; Huffenberger, K M; Jaffe, A H; Jones, W C; Kaplan, J; Kneissl, R; Knox, L; Kunz, M; Lagache, G; Lamarre, J -M; Lange, A E; Lasenby, A; Lavabre, A; Lawrence, C R; Jeune, M Le; Leroy, C; Lesgourgues, J; Lewis, A; Macías-Pérez, J F; MacTavish, C J; Maffei, B; Mandolesi, N; Mann, R; Marleau, F; Marshall, D J; Masi, S; Matsumura, T; McAuley, I; McGehee, P; Melin, J -B; Mercier, C; Mitra, S; Miville-Deschênes, M -A; Moneti, A; Montier, L; Mortlock, D; Murphy, A; Nati, F; Netterfield, C B; N\\orgaard-Nielsen, H U; North, C; Noviello, F; Novikov, D; Osborne, S; Pajot, F; Patanchon, G; Peacocke, T; Pearson, T J; Perdereau, O; Perotto, L; Piacentini, F; Piat, M; Plaszczynski, S; Pointecouteau, E; Ponthieu, N; Prézeau, G; Prunet, S; Puget, J -L; Reach, W T; Remazeilles, M; Renault, C; Riazuelo, A; Ristorcelli, I; Rocha, G; Rosset, C; Roudier, G; Rowan-Robinson, M; Rusholme, B; Saha, R; Santos, D; Savini, G; Schaefer, B M; Shellard, P; Spencer, L; Starck, J -L; Stolyarov, V; Stompor, R; Sudiwala, R; Sunyaev, R; Sutton, D; Sygnet, J -F; Tauber, J A; Thum, C; Torre, J -P; Touze, F; Tristram, M; Van Leeuwen, F; Vibert, L; Vibert, D; Wandelt, B D; White, S D M; Wiesemeyer, H; Woodcraft, A; Yurchenko, V; Yvon, D; Zacchei, A

    2011-01-01

    We describe the processing of the 334 billion raw data samples from the High Frequency Instrument (hereafter HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545 and 857GHz with an angular resolution ranging from 9.9 to 4.4 arcmin. The white noise level is around 1.5 microK.degree or less in the 3 main CMB channels (100-217GHz). The photometric accuracy is better than 2% at frequencies lower or equal to 353GHz, and around 7% at the two highest frequencies. The maps created by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears to be of high quality and we expect that with further refinements of the data processing we should be abl...

  9. Advances to Dynamic Mechanical Analysis: High Frequencies and Environmental Applications

    Science.gov (United States)

    Foreman, Jonathon

    2002-03-01

    In dynamic mechanical analysis (DMA) the sample is deformed and released sinusoidally providing information about the modulus and damping behaviors with respect to temperature, time, oscillation frequency and amplitude of motion. It offers exceptional sensitivity to glass transitions and secondary relaxations. Recent developments have increased the frequency range up to 1000 Hz, which allow properties measurements under actual end-use conditions. Furthermore high frequencies enhance the ability to determine the kinetics of viscoelastic relaxations. Another recent development allows DMA measurements while samples are immersed in fluids or enveloped in gases. Most significant is the ability to alter the furnace control parameters to account for the thermal properties of the environment used. This configuration allows temperature-controlled measurements (both heating and isothermal profiles) on a wide range of sample shapes and sizes. Environmental DMA is easier to interpret than standard DMA (in air or inert gas) on preconditioned samples because such samples often lose the conditioning solvent or gas during the measurement. easy.com/dma_apps.asp>Examples will show real-time property changes from the interaction of unconditioned materials with conditioning environments and experiments on pre-conditioned materials that are heated while immersed in conditioning environments. -------------------------------------------------------------

  10. High frequency production of haploid embryos in asparagus anther culture.

    Science.gov (United States)

    Feng, X R; Wolyn, D J

    1991-12-01

    A method for obtaining a high frequency of haploid asparagus embryos through anther culture was developed. Flowers collected from plants in the field in July, August and September 1990, for the genotype G203, were stored at 5°C for 24 h. Anthers were placed on Murashige and Skoog medium (MS) containing 500 mg l (-1) casein hydrolysate, 800 mg l(-1) glutamine, 2 mg l (-1) NAA, 1 mg l (-1) BA and 5 % sucrose at 32 °C in the dark for three to four weeks to induce calli. Calli were then grown at 25 °C with a 16 h photoperiod for three to four weeks. Developing embryos and calli were transferred to embryo maturation medium, MS containing 6% sucrose, 0.1 mg l (-1) NAA, 0.1 mg l (-1) kinetin and 0.65 mg l (-1) ancymidol, for four weeks. More than 50% of the recovered mature embryos germinated on MS containing l mg l (-1) GA3. Anthers with microspores at the late-uninucleate stage had the highest frequency of total and embryogenic calli formation, 40% and 15%, respectively. Each embryogenic callus usually produced 10-15 embryos. Aproximately 75 plants per 100 anthers cultured were recovered: 76% haploid, 22% diploid and 2% triploid. High temperature was critical for the induction of embryogenic callus.

  11. Challenges in graphene integration for high-frequency electronics

    Science.gov (United States)

    Giannazzo, F.; Fisichella, G.; Greco, G.; Roccaforte, F.

    2016-06-01

    This paper provides an overview of the state-of-the-art research on graphene (Gr) for high-frequency (RF) devices. After discussing current limitations of lateral Gr RF transistors, novel vertical devices concepts such as the Gr Base Hot Electron Transistor (GBHET) will be introduced and the main challenges in Gr integration within these architectures will be discussed. In particular, a GBHET device based on Gr/AlGaN/GaN heterostructure will be considered. An approach to the fabrication of this heterostructure by transfer of CVD grown Gr on copper to the AlGaN surface will be presented. The morphological and electrical properties of this system have been investigated at nanoscale by atomic force microscopy (AFM) and conductive atomic force microscopy (CAFM). In particular, local current-voltage measurements by the CAFM probe revealed the formation of a Schottky contact with low barrier height (˜0.41 eV) and excellent lateral uniformity between Gr and AlGaN. Basing on the electrical parameters extracted from this characterization, the theoretical performances of a GBHET formed by a metal/Al2O3/Gr/AlGaN/GaN stack have been evaluated.

  12. Very high frequency plasma reactant for atomic layer deposition

    Science.gov (United States)

    Oh, Il-Kwon; Yoo, Gilsang; Yoon, Chang Mo; Kim, Tae Hyung; Yeom, Geun Young; Kim, Kangsik; Lee, Zonghoon; Jung, Hanearl; Lee, Chang Wan; Kim, Hyungjun; Lee, Han-Bo-Ram

    2016-11-01

    Although plasma-enhanced atomic layer deposition (PE-ALD) results in several benefits in the formation of high-k dielectrics, including a low processing temperature and improved film properties compared to conventional thermal ALD, energetic radicals and ions in the plasma cause damage to layer stacks, leading to the deterioration of electrical properties. In this study, the growth characteristics and film properties of PE-ALD Al2O3 were investigated using a very-high-frequency (VHF) plasma reactant. Because VHF plasma features a lower electron temperature and higher plasma density than conventional radio frequency (RF) plasma, it has a larger number of less energetic reaction species, such as radicals and ions. VHF PE-ALD Al2O3 shows superior physical and electrical properties over RF PE-ALD Al2O3, including high growth per cycle, excellent conformality, low roughness, high dielectric constant, low leakage current, and low interface trap density. In addition, interlayer-free Al2O3 on Si was achieved in VHF PE-ALD via a significant reduction in plasma damage. VHF PE-ALD will be an essential process to realize nanoscale devices that require precise control of interfaces and electrical properties.

  13. Tecnologia radio cognitiva en la banda ultra high frequency (UHF

    Directory of Open Access Journals (Sweden)

    Hernán Paz Penagos

    2014-01-01

    Full Text Available Mobile cellular communication companies in Colombia require more spectrum resources to expand their portfolio of services. However, additional frequency bands for that particular purpose are scarce, yet it is well known that there are many underutilized licensed bands. Therefore new radio technologies are being studied in order to solve this problem, e.g. Software Defined Radio SDR Cognitive Radio CR and Dynamic Spectrum Access DSA. These strategies recommend mobility across the radio spectrum to meet various needs and achieve greater efficiency when managing such a scarce resource. In this context, a case study is presented in an attempt to examine the require¬ments that must be met for the implementation of cognitive radio networks in Bogota. The case study includes evaluation for the possibility of migration from cellular communications to cognitive radio since the bands assigned to UltraHigh Frequency UHF television offer possible free-of-interference coexistence between the two services (i.e. Cellular and TV. The study shows feasibility to migration; however, the implementations of cognitive radio need availability of hardware, software and flexible radio platforms.

  14. Superior oblique surgery: when and how?

    Directory of Open Access Journals (Sweden)

    Taylan Şekeroğlu H

    2013-08-01

    Full Text Available Hande Taylan Şekeroğlu,1 Ali Sefik Sanac,1 Umut Arslan,2 Emin Cumhur Sener11Department of Ophthalmology, 2Department of Biostatistics, Hacettepe University Faculty of Medicine, Ankara, TurkeyBackground: The purpose of this paper is to review different types of superior oblique muscle surgeries, to describe the main areas in clinical practice where superior oblique surgery is required or preferred, and to discuss the preferred types of superior oblique surgery with respect to their clinical outcomes.Methods: A consecutive nonrandomized retrospective series of patients who had undergone superior oblique muscle surgery as a single procedure were enrolled in the study. The diagnosis, clinical features, preoperative and postoperative vertical deviations in primary position, type of surgery, complications, and clinical outcomes were reviewed. The primary outcome measures were the type of strabismus and the type of superior oblique muscle surgery. The secondary outcome measure was the results of the surgeries.Results: The review identified 40 (20 male, 20 female patients with a median age of 6 (2–45 years. Nineteen patients (47.5% had Brown syndrome, eleven (27.5% had fourth nerve palsy, and ten (25.0% had horizontal deviations with A pattern. The most commonly performed surgery was superior oblique tenotomy in 29 (72.5% patients followed by superior oblique tuck in eleven (27.5% patients. The amount of vertical deviation in the fourth nerve palsy and Brown syndrome groups (P = 0.01 for both and the amount of A pattern in the A pattern group were significantly reduced postoperatively (P = 0.02.Conclusion: Surgery for the superior oblique muscle requires experience and appropriate preoperative evaluation in view of its challenging nature. The main indications are Brown syndrome, fourth nerve palsy, and A pattern deviations. Superior oblique surgery may be effective in terms of pattern collapse and correction of vertical deviations in primary

  15. 77 FR 8222 - Notice Requesting Nominations for the Subcommittee on Automated and High Frequency Trading

    Science.gov (United States)

    2012-02-14

    ... COMMISSION Notice Requesting Nominations for the Subcommittee on Automated and High Frequency Trading AGENCY... Automated and High Frequency Trading within the Technology Advisory Committee. SUMMARY: The Commodity... Automated and High Frequency Trading (Subcommittee) under the auspices of the Technology Advisory Committee...

  16. Magnetoencephalography Detection of High-Frequency Oscillations in the Developing Brain

    Directory of Open Access Journals (Sweden)

    Kimberly eLeiken

    2014-12-01

    Full Text Available Increasing evidence from invasive intracranial recordings suggests that the matured brain generates both physiological and pathological high-frequency signals. The present study was designed to detect high-frequency brain signals in the developing brain using newly developed magnetoencephalography (MEG methods. Twenty healthy children were studied with a high sampling rate MEG system. Functional high-frequency brain signals were evoked by electrical stimulation applied to the index fingers. To determine if the high-frequency neuromagnetic signals are true brain responses in high-frequency range, we analyzed the MEG data using the conventional averaging as well as newly developed time-frequency analysis along with beamforming. The data of healthy children showed that very high-frequency brain signals (> 1000 Hz in the somatosensory cortex in the developing brain could be detected and localized using MEG. The amplitude of very high-frequency brain signals was significantly weaker than that of the low-frequency brain signals. Very high-frequency brain signals showed a much earlier latency than those of a low-frequency. Magnetic source imaging (MSI revealed that a portion of the high-frequency signals was from the somatosensory cortex, another portion of the high-frequency signals was probably from the thalamus. Our results provide evidence that the developing brain generates high-frequency signals that can be detected with the noninvasive technique of MEG. MEG detection of high-frequency brain signals may open a new window for the study of developing brain function.

  17. Tsunami Arrival Detection with High Frequency (HF Radar

    Directory of Open Access Journals (Sweden)

    Donald Barrick

    2012-05-01

    Full Text Available Quantitative real-time observations of a tsunami have been limited to deep-water, pressure-sensor observations of changes in the sea surface elevation and observations of sea level fluctuations at the coast, which are essentially point measurements. Constrained by these data, models have been used for predictions and warning of the arrival of a tsunami, but to date no system exists for local detection of an actual incoming wave with a significant warning capability. Networks of coastal high frequency (HF-radars are now routinely observing surface currents in many countries. We report here on an empirical method for the detection of the initial arrival of a tsunami, and demonstrate its use with results from data measured by fourteen HF radar sites in Japan and USA following the magnitude 9.0 earthquake off Sendai, Japan, on 11 March 2011. The distance offshore at which the tsunami can be detected, and hence the warning time provided, depends on the bathymetry: the wider the shallow continental shelf, the greater this time. We compare arrival times at the radars with those measured by neighboring tide gauges. Arrival times measured by the radars preceded those at neighboring tide gauges by an average of 19 min (Japan and 15 min (USA The initial water-height increase due to the tsunami as measured by the tide gauges was moderate, ranging from 0.3 to 2 m. Thus it appears possible to detect even moderate tsunamis using this method. Larger tsunamis could obviously be detected further from the coast. We find that tsunami arrival within the radar coverage area can be announced 8 min (i.e., twice the radar spectral time resolution after its first appearance. This can provide advance warning of the tsunami approach to the coastline locations.

  18. Semiclassical methods for high frequency wave propagation in periodic media

    Science.gov (United States)

    Delgadillo, Ricardo A.

    We will study high-frequency wave propagation in periodic media. A typical example is given by the Schrodinger equation in the semiclassical regime with a highly oscillatory periodic potential and external smooth potential. This problem presents a numerical challenge when in the semiclassical regime. For example, conventional methods such as finite differences and spectral methods leads to high numerical cost, especially in higher dimensions. For this reason, asymptotic methods like the frozen Gaussian approximation (FGA) was developed to provide an efficient computational tool. Prior to the development of the FGA, the geometric optics and Gaussian beam methods provided an alternative asymptotic approach to solving the Schrodinger equation efficiently. Unlike the geometric optics and Gaussian beam methods, the FGA does not lose accuracy due to caustics or beam spreading. In this thesis, we will briefly review the geometric optics, Gaussian beam, and FGA methods. The mathematical techniques used by these methods will aid us in formulating the Bloch-decomposition based FGA. The Bloch-decomposition FGA generalizes the FGA to wave propagation in periodic media. We will establish the convergence of the Bloch-decomposition based FGA to the true solution for Schrodinger equation and develop a gauge-invariant algorithm for the Bloch-decomposition based FGA. This algorithm will avoid the numerical difficulty of computing the gauge-dependent Berry phase. We will show the numerical performance of our algorithm by several one-dimensional examples. Lastly, we will propose a time-splitting FGA-based artificial boundary conditions for solving the one-dimensional nonlinear Schrodinger equation (NLS) on an unbounded domain. The NLS will be split into two parts, the linear and nonlinear parts. For the linear part we will use the following absorbing boundary strategy: eliminate Gaussian functions whose centers are too distant to a fixed domain.

  19. Robust Optimization Design Algorithm for High-Frequency TWTs

    Science.gov (United States)

    Wilson, Jeffrey D.; Chevalier, Christine T.

    2010-01-01

    Traveling-wave tubes (TWTs), such as the Ka-band (26-GHz) model recently developed for the Lunar Reconnaissance Orbiter, are essential as communication amplifiers in spacecraft for virtually all near- and deep-space missions. This innovation is a computational design algorithm that, for the first time, optimizes the efficiency and output power of a TWT while taking into account the effects of dimensional tolerance variations. Because they are primary power consumers and power generation is very expensive in space, much effort has been exerted over the last 30 years to increase the power efficiency of TWTs. However, at frequencies higher than about 60 GHz, efficiencies of TWTs are still quite low. A major reason is that at higher frequencies, dimensional tolerance variations from conventional micromachining techniques become relatively large with respect to the circuit dimensions. When this is the case, conventional design- optimization procedures, which ignore dimensional variations, provide inaccurate designs for which the actual amplifier performance substantially under-performs that of the design. Thus, this new, robust TWT optimization design algorithm was created to take account of and ameliorate the deleterious effects of dimensional variations and to increase efficiency, power, and yield of high-frequency TWTs. This design algorithm can help extend the use of TWTs into the terahertz frequency regime of 300-3000 GHz. Currently, these frequencies are under-utilized because of the lack of efficient amplifiers, thus this regime is known as the "terahertz gap." The development of an efficient terahertz TWT amplifier could enable breakthrough applications in space science molecular spectroscopy, remote sensing, nondestructive testing, high-resolution "through-the-wall" imaging, biomedical imaging, and detection of explosives and toxic biochemical agents.

  20. Low and High-Frequency Field Potentials of Cortical Networks ...

    Science.gov (United States)

    Neural networks grown on microelectrode arrays (MEAs) have become an important, high content in vitro assay for assessing neuronal function. MEA experiments typically examine high- frequency (HF) (>200 Hz) spikes, and bursts which can be used to discriminate between different pharmacological agents/chemicals. However, normal brain activity is additionally composed of integrated low-frequency (0.5-100 Hz) field potentials (LFPs) which are filtered out of MEA recordings. The objective of this study was to characterize the relationship between HF and LFP neural network signals, and to assess the relative sensitivity of LFPs to selected neurotoxicants. Rat primary cortical cultures were grown on glass, single-well MEA chips. Spontaneous activity was sampled at 25 kHz and recorded (5 min) (Multi-Channel Systems) from mature networks (14 days in vitro). HF (spike, mean firing rate, MFR) and LF (power spectrum, amplitude) components were extracted from each network and served as its baseline (BL). Next, each chip was treated with either 1) a positive control, bicuculline (BIC, 25μM) or domoic acid (DA, 0.3μM), 2) or a negative control, acetaminophen (ACE, 100μM) or glyphosate (GLY, 100μM), 3) a solvent control (H2O or DMSO:EtOH), or 4) a neurotoxicant, (carbaryl, CAR 5, 30μM ; lindane, LIN 1, 10μM; permethrin, PERM 25, 50μM; triadimefon, TRI 5, 65μM). Post treatment, 5 mins of spontaneous activity was recorded and analyzed. As expected posit

  1. Achieving High-Frequency Optical Control of Synaptic Transmission

    Science.gov (United States)

    Jackman, Skyler L.; Beneduce, Brandon M.; Drew, Iain R.

    2014-01-01

    The optogenetic tool channelrhodopsin-2 (ChR2) is widely used to excite neurons to study neural circuits. Previous optogenetic studies of synapses suggest that light-evoked synaptic responses often exhibit artificial synaptic depression, which has been attributed to either the inability of ChR2 to reliably fire presynaptic axons or to ChR2 elevating the probability of release by depolarizing presynaptic boutons. Here, we compare light-evoked and electrically evoked synaptic responses for high-frequency stimulation at three synapses in the mouse brain. At synapses from Purkinje cells to deep cerebellar nuclei neurons (PC→DCN), light- and electrically evoked synaptic currents were remarkably similar for ChR2 expressed transgenically or with adeno-associated virus (AAV) expression vectors. For hippocampal CA3→CA1 synapses, AAV expression vectors of serotype 1, 5, and 8 led to light-evoked synaptic currents that depressed much more than electrically evoked currents, even though ChR2 could fire axons reliably at up to 50 Hz. The disparity between optical and electrical stimulation was eliminated when ChR2 was expressed transgenically or with AAV9. For cerebellar granule cell to stellate cell (grc→SC) synapses, AAV1 also led to artificial synaptic depression and AAV9 provided superior performance. Artificial synaptic depression also occurred when stimulating over presynaptic boutons, rather than axons, at CA3→CA1 synapses, but not at PC→DCN synapses. These findings indicate that ChR2 expression methods and light stimulation techniques influence synaptic responses in a neuron-specific manner. They also identify pitfalls associated with using ChR2 to study synapses and suggest an approach that allows optogenetics to be applied in a manner that helps to avoid potential complications. PMID:24872574

  2. Regenerator Operation at Very High Frequencies for Microcryocoolers

    Science.gov (United States)

    Radebaugh, Ray; O'Gallagher, Agnes

    2006-04-01

    The size of Stirling and Stirling-type pulse tube cryocoolers is dominated by the size of the pressure oscillator. Such cryocoolers typically operate at frequencies up to about 60 Hz for cold-end temperatures above about 60 K. Higher operating frequencies would allow the size and mass of the pressure oscillator to be reduced for a given power input. However, simply increasing the operating frequency leads to large losses in the regenerator. The simple analytical equations derived here show how the right combination of frequency and pressure, along with optimized regenerator geometry, can lead to successful regenerator operation at frequencies up to 1 kHz. Efficient regenerator operation at such high frequencies is possible only with pressures of about 5 to 8 MPa and with very small hydraulic diameters and lengths. Other geometrical parameters must also be optimized for such conditions. The analytical equations are used to provide guidance to the right combination of parameters. We give example numerical calculations with REGEN3.2 in the paper for 60 Hz, 400 Hz, and 1000 Hz operation of optimized screen regenerators and show that the coefficient of performance at 400 Hz and 1000 Hz is about 78 % and 68 %, respectively, of that for 60 Hz when an average pressure of 7 MPa is used with the higher frequency, compared with 2.5 MPa for 60 Hz operation. The 1000 Hz coefficient of performance for parallel tubes is about the same as that of the screen geometry at 60 Hz. The compressor and cold-end swept volumes are reduced by a factor of 47 at 1000 Hz, compared with the 60 Hz case for the same input acoustic power, which can enable the development of microcryocoolers for MEMS applications.

  3. High-frequency homogenization for travelling waves in periodic media.

    Science.gov (United States)

    Harutyunyan, Davit; Milton, Graeme W; Craster, Richard V

    2016-07-01

    We consider high-frequency homogenization in periodic media for travelling waves of several different equations: the wave equation for scalar-valued waves such as acoustics; the wave equation for vector-valued waves such as electromagnetism and elasticity; and a system that encompasses the Schrödinger equation. This homogenization applies when the wavelength is of the order of the size of the medium periodicity cell. The travelling wave is assumed to be the sum of two waves: a modulated Bloch carrier wave having crystal wavevector [Formula: see text] and frequency ω1 plus a modulated Bloch carrier wave having crystal wavevector [Formula: see text] and frequency ω2. We derive effective equations for the modulating functions, and then prove that there is no coupling in the effective equations between the two different waves both in the scalar and the system cases. To be precise, we prove that there is no coupling unless ω1=ω2 and [Formula: see text] where Λ=(λ1λ2…λ d ) is the periodicity cell of the medium and for any two vectors [Formula: see text] the product a⊙b is defined to be the vector (a1b1,a2b2,…,adbd ). This last condition forces the carrier waves to be equivalent Bloch waves meaning that the coupling constants in the system of effective equations vanish. We use two-scale analysis and some new weak-convergence type lemmas. The analysis is not at the same level of rigour as that of Allaire and co-workers who use two-scale convergence theory to treat the problem, but has the advantage of simplicity which will allow it to be easily extended to the case where there is degeneracy of the Bloch eigenvalue.

  4. Very high frequency plasma reactant for atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Il-Kwon; Yoo, Gilsang; Yoon, Chang Mo [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Kim, Tae Hyung; Yeom, Geun Young [Department of Advanced Materials Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, Kangsik; Lee, Zonghoon [School Materials Science and Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919 (Korea, Republic of); Jung, Hanearl; Lee, Chang Wan [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Kim, Hyungjun, E-mail: hyungjun@yonsei.ac.kr [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Lee, Han-Bo-Ram, E-mail: hbrlee@inu.ac.kr [Department of Materials Science and Engineering, Incheon National University, 406-840 Incheon (Korea, Republic of)

    2016-11-30

    Highlights: • Fundamental research plasma process for thin film deposition is presented. • VHF plasma source for PE-ALD Al{sub 2}O{sub 3} was employed to reduce plasma damage. • The use of VHF plasma improved all of the film qualities and growth characteristics. - Abstract: Although plasma-enhanced atomic layer deposition (PE-ALD) results in several benefits in the formation of high-k dielectrics, including a low processing temperature and improved film properties compared to conventional thermal ALD, energetic radicals and ions in the plasma cause damage to layer stacks, leading to the deterioration of electrical properties. In this study, the growth characteristics and film properties of PE-ALD Al{sub 2}O{sub 3} were investigated using a very-high-frequency (VHF) plasma reactant. Because VHF plasma features a lower electron temperature and higher plasma density than conventional radio frequency (RF) plasma, it has a larger number of less energetic reaction species, such as radicals and ions. VHF PE-ALD Al{sub 2}O{sub 3} shows superior physical and electrical properties over RF PE-ALD Al{sub 2}O{sub 3}, including high growth per cycle, excellent conformality, low roughness, high dielectric constant, low leakage current, and low interface trap density. In addition, interlayer-free Al{sub 2}O{sub 3} on Si was achieved in VHF PE-ALD via a significant reduction in plasma damage. VHF PE-ALD will be an essential process to realize nanoscale devices that require precise control of interfaces and electrical properties.

  5. High-frequency TRNS reduces BOLD activity during visuomotor learning.

    Directory of Open Access Journals (Sweden)

    Catarina Saiote

    Full Text Available Transcranial direct current stimulation (tDCS and transcranial random noise stimulation (tRNS consist in the application of electrical current of small intensity through the scalp, able to modulate perceptual and motor learning, probably by changing brain excitability. We investigated the effects of these transcranial electrical stimulation techniques in the early and later stages of visuomotor learning, as well as associated brain activity changes using functional magnetic resonance imaging (fMRI. We applied anodal and cathodal tDCS, low-frequency and high-frequency tRNS (lf-tRNS, 0.1-100 Hz; hf-tRNS 101-640 Hz, respectively and sham stimulation over the primary motor cortex (M1 during the first 10 minutes of a visuomotor learning paradigm and measured performance changes for 20 minutes after stimulation ceased. Functional imaging scans were acquired throughout the whole experiment. Cathodal tDCS and hf-tRNS showed a tendency to improve and lf-tRNS to hinder early learning during stimulation, an effect that remained for 20 minutes after cessation of stimulation in the late learning phase. Motor learning-related activity decreased in several regions as reported previously, however, there was no significant modulation of brain activity by tDCS. In opposition to this, hf-tRNS was associated with reduced motor task-related-activity bilaterally in the frontal cortex and precuneous, probably due to interaction with ongoing neuronal oscillations. This result highlights the potential of lf-tRNS and hf-tRNS to differentially modulate visuomotor learning and advances our knowledge on neuroplasticity induction approaches combined with functional imaging methods.

  6. Recent Improvements in High-Frequency Eddy Current Conductivity Spectroscopy

    Science.gov (United States)

    Abu-Nabah, Bassam A.; Nagy, Peter B.

    2008-02-01

    Due to its frequency-dependent penetration depth, eddy current measurements are capable of mapping near-surface residual stress profiles based on the so-called piezoresistivity effect, i.e., the stress-dependence of electric conductivity. To capture the peak compressive residual stress in moderately shot-peened (Almen 4-8A) nickel-base superalloys, the eddy current inspection frequency has to go as high as 50-80 MHz. Recently, we have reported the development of a new high-frequency eddy current conductivity measuring system that offers an extended inspection frequency range up to 80 MHz. Unfortunately, spurious self- and stray-capacitance effects render the complex coil impedance variation with lift-off more nonlinear as the frequency increases, which makes it difficult to achieve accurate apparent eddy current conductivity (AECC) measurements with the standard four-point linear interpolation method beyond 25 MHz. In this paper, we will demonstrate that reducing the coil size reduces its sensitivity to capacitive lift-off variations, which is just the opposite of the better known inductive lift-off effect. Although reducing the coil size also reduces its absolute electric impedance and relative sensitivity to conductivity variations, a smaller coil still yields better overall performance for residual stress assessment. In addition, we will demonstrate the benefits of a semi-quadratic interpolation scheme that, together with the reduced lift-off sensitivity of the smaller probe coil, minimizes and in some cases completely eliminates the sensitivity of AECC measurements to lift-off uncertainties. These modifications allow us to do much more robust measurements up to as high as 80-100 MHz with the required high relative accuracy of +/-0.1%.

  7. Castration alters protein balance after high-frequency muscle contraction.

    Science.gov (United States)

    Steiner, Jennifer L; Fukuda, David H; Rossetti, Michael L; Hoffman, Jay R; Gordon, Bradley S

    2017-02-01

    Resistance exercise increases muscle mass by shifting protein balance in favor of protein accretion. Androgens independently alter protein balance, but it is unknown whether androgens alter this measure after resistance exercise. To answer this, male mice were subjected to sham or castration surgery 7-8 wk before undergoing a bout of unilateral, high-frequency, electrically induced muscle contractions in the fasted or refed state. Puromycin was injected 30 min before euthanasia to measure protein synthesis. The tibialis anterior was analyzed 4 h postcontraction. In fasted mice, neither basal nor stimulated rates of protein synthesis were affected by castration despite lower phosphorylation of mechanistic target of rapamycin in complex 1 (mTORC1) substrates [p70S6K1 (Thr389) and 4E-BP1 (Ser65)]. Markers of autophagy (LC3 II/I ratio and p62 protein content) were elevated by castration, and these measures remained elevated above sham values after contractions. Furthermore, in fasted mice, the protein content of Regulated in Development and DNA Damage 1 (REDD1) was correlated with LC3 II/I in noncontracted muscle, whereas phosphorylation of uncoordinated like kinase 1 (ULK1) (Ser757) was correlated with LC3 II/I in the contracted muscle. When mice were refed before contractions, protein synthesis and mTORC1 signaling were not affected by castration in either the noncontracted or contracted muscle. Conversely, markers of autophagy remained elevated in the muscles of refed, castrated mice even after contractions. These data suggest the castration-mediated elevation in baseline autophagy reduces the absolute positive shift in protein balance after muscle contractions in the refed or fasted states.

  8. High-frequency homogenization for travelling waves in periodic media

    Science.gov (United States)

    Harutyunyan, Davit; Milton, Graeme W.; Craster, Richard V.

    2016-07-01

    We consider high-frequency homogenization in periodic media for travelling waves of several different equations: the wave equation for scalar-valued waves such as acoustics; the wave equation for vector-valued waves such as electromagnetism and elasticity; and a system that encompasses the Schrödinger equation. This homogenization applies when the wavelength is of the order of the size of the medium periodicity cell. The travelling wave is assumed to be the sum of two waves: a modulated Bloch carrier wave having crystal wavevector k and frequency ω1 plus a modulated Bloch carrier wave having crystal wavevector m and frequency ω2. We derive effective equations for the modulating functions, and then prove that there is no coupling in the effective equations between the two different waves both in the scalar and the system cases. To be precise, we prove that there is no coupling unless ω1=ω2 and (k -m )⊙Λ ∈2 π Zd, where Λ=(λ1λ2…λd) is the periodicity cell of the medium and for any two vectors a =(a1,a2,…,ad),b =(b1,b2,…,bd)∈Rd, the product a⊙b is defined to be the vector (a1b1,a2b2,…,adbd). This last condition forces the carrier waves to be equivalent Bloch waves meaning that the coupling constants in the system of effective equations vanish. We use two-scale analysis and some new weak-convergence type lemmas. The analysis is not at the same level of rigour as that of Allaire and co-workers who use two-scale convergence theory to treat the problem, but has the advantage of simplicity which will allow it to be easily extended to the case where there is degeneracy of the Bloch eigenvalue.

  9. Multiple Optical Probing of High Frequency Semiconductor Devices

    Science.gov (United States)

    1989-11-14

    University of California Dept of Electrical Engineering Los Angeles, CA 90024 ( 11 9. SPONSORING/ MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10...for some discrepancies, the two measurement techniques rhodamine 6G (R6G) dye and has a cavity dumper which allows are in good agreement. The

  10. Imaging of the skin and subcutaneous tissue using classical and high-frequency ultrasonographies in anti-cellulite therapy.

    Science.gov (United States)

    Mlosek, Robert Krzysztof; Dębowska, Renata Maria; Lewandowski, Marcin; Malinowska, Sylwia; Nowicki, Andrzej; Eris, Irena

    2011-11-01

    The development of ultrasonography allowed for skin imaging used in dermatology and esthetic medicine. By means of classic and high-frequency ultrasonographies, changes within the dermis and subcutaneous tissue can be presented. The aim of this study was to show the possibilities of applying classic and high-frequency ultrasonographies in esthetic dermatology based on monitoring various types of anti-cellulite therapies. Sixty-one women with cellulite were assigned to two smaller groups. One group was using anti-cellulite cream and the second group was a placebo group. The ultrasound examination was carried out before the initiation and after the completion of the treatment and evaluated epidermal echoes, the thickness of the subcutaneous tissue and the dermis, dermis echogenicity, the length and surface area of the subcutaneous tissue fascicles growing into the dermis, and the presence or absence of edemas. After the completion of the treatment, a statistically significant difference was observed. The most useful parameters were as follows: the thickness of the subcutaneous tissue, echogenicity, the surface area and length of the subcutaneous tissue, as well as the presence of edemas. The discussed changes were not observed in the placebo group. Classic and high-frequency ultrasonographies are useful methods for monitoring anti-cellulite therapies. © 2011 John Wiley & Sons A/S.

  11. Development of high frequency annular array ultrasound transducers

    Science.gov (United States)

    Gottlieb, Emanuel John

    The advantage of ultrasonic annular arrays over conventional single element transducers has been in the ability to transmit focus at multiple points throughout the depth of field, as well as receive dynamic focus. Today, annular, linear and multidimensional array imaging systems are not commercially available at frequencies greater than 20 MHz. The fabrication technology used to develop a high frequency (>50 MHz) annular array transducer is presented. A 9 mum P(VDF-TrFE) film was bonded to gold annuli electrodes on the top layer of a two sided polyimide flexible circuit. Each annulus was separated by a 30 mum kerf and had several electroplated micro vias that connected to electrode traces on the bottom side of the polyimide flexible circuit. The array's performance was evaluated by measuring the electrical impedance, pulse echo response and crosstalk measurement for each element in the array. In order to improve device sensitivity each element was electrically matched to an impedance magnitude of 50 O and 0° phase at resonance. The average round trip insertion loss measured for the array and compensated for diffraction effects was -33.5 dB. The measured average center frequency and bandwidth of an element was 55 MHz and 47 respectively. The measured crosstalk between adjacent elements remained below -29 dB at the center frequency in water. A vertical wire phantom was imaged using a single focus transmit beamformer and dynamic focusing receive beamformer. This image showed a significant improvement in lateral resolution over a range of 9 mm after the dynamic focusing receive algorithm was applied. These results correlated well with predictions from a Field II simulation. After beamforming the minimum lateral resolution (-6 dB) was 108 mum at the focus. Preliminary ultrasound B-mode images of the rabbit eye using this transducer were shown in conjunction with a multi-channel digital beamformer. A feasibility study of designing and fabricating tunable copolymer

  12. A Compact High Frequency Doppler Radio Scatterometer for Coastal Oceanography

    Science.gov (United States)

    Flament, P. J.; Harris, D.; Flament, M.; Fernandez, I. Q.; Hlivak, R.; Flores-vidal, X.; Marié, L.

    2016-12-01

    A low-power High Frequency Doppler Radar has been designed for large series production. The use of commercial-off-the-shelf components is maximized to minimize overall cost. Power consumption is reduced to 130W in full duty and 20W in stand-by under 20-36 V-DC, thus enabling solar/wind and/or fuel cell operation by default. For 8 channels, commercial components and sub-assemblies cost less than k20 excluding coaxial antenna cables, and less than four man-weeks of technician suffice for integration, testing and calibration, suggesting a final cost of about k36, based on production batches of 25 units. The instrument is integrated into passively-cooled 90x60x20 cm3 field-deployable enclosures, combining signal generation, transmitter, received, A/D converter and computer, alleviating the need for additional protection such as a container or building. It uses frequency-ramped continuous wave signals, and phased-array transmissions to decouple the direct path to the receivers. Five sub-assemblies are controlled by a Linux embedded computer: (i) direct digital synthesis of transmit and orthogonal local oscillator signals, derived from a low phase noise oven-controlled crystal; (ii) distributed power amplifiers totaling 5 W, integrated into λ/8 passive transmit antenna monopoles; (iii) λ/12 compact active receive antenna monopoles with embedded out-of-band rejection filters; (iv) analog receivers based on complex demodulation by double-balanced mixers, translating the HF spectrum to the audio band; (v) 24-bit analog-to-digital sigma-delta conversion at 12 kHz with 512x oversampling, followed by decimation to a final sampling frequency of 750 Hz. Except for the HF interference rejection filters, the electronics can operate between 3 and 50 MHz with no modification. At 13.5 MHz, 5 W transmit power, 15 min integration time, the high signal-to-noise ratio permits a typical range of 120 km for currents measurements with 8-antenna beam-forming. The University of Hawaii HFR

  13. Variable Temperature High-Frequency Response of Heterostructure Transistors

    Science.gov (United States)

    Laskar, Joy

    1992-01-01

    The development of high performance heterostructure transistors is essential for emerging opto-electronic integrated circuits (OEICs) and monolithic microwave integrated circuits (MMICs). Applications for OEICs and MMICs include the rapidly growing telecommunications and personal communications markets. The key to successful OEIC and MMIC chip sets is the development of high performance, cost-effective technologies. In this work, several different transistor structures are investigated to determine the potential for high speed performance and the physical mechanisms controlling the ultimate device operation. A cryogenic vacuum microwave measurement system has been developed to study the high speed operation of modulation doped field-effect transistors (MODFETs), doped channel metal insulator field-effect transistors (MISFETs), and metal semiconductor field-effect transistors (MESFETs). This study has concluded that the high field velocity and not the low field mobility is what controls high frequency operation of GaAs based field-effect transistors. Both Al_{rm x} Ga_{rm 1-x}As/GaAs and InP/In_{rm y}Ga _{rm 1-y}As heterostructure bipolar transistors (HBTs) have also been studied at reduced lattice temperatures to understand the role of diffusive transport in the Al_{rm x} Ga_{rm 1-x}As/GaAs HBT and nonequilibrium transport in the InP/In _{rm y}Ga_ {rm 1-y}As HBT. It is shown that drift/diffusion formulation must be modified to accurately estimate the base delay time in the conventional Al _{rm x}Ga_ {rm 1-x}As/GaAs HBT. The reduced lattice temperature operation of the InP/In_ {rm y}Ga_{rm 1-y}As HBT demonstrates extreme nonequilibrium transport in the neutral base and collector space charge region with current gain cut-off frequency exceeding 300 GHz, which is the fastest reported transistor to date. Finally, the MODFET has been investigated as a three-terminal negative differential resistance (NDR) transistor. The existence of real space transfer is confirmed by

  14. Inferring Planetary Obliquity Using Rotational & Orbital Photometry

    CERN Document Server

    Schwartz, Joel C; Haggard, Hal M; Pallé, Eric; Cowan, Nicolas B

    2015-01-01

    The obliquity of a terrestrial planet is an important clue about its formation and critical to its climate. Previous studies using simulated photometry of Earth show that continuous observations over most of a planet's orbit can be inverted to infer obliquity. We extend this approach to single-epoch observations for planets with arbitrary albedo maps. For diffuse reflection, the flux seen by a distant observer is the product of the planet's albedo map, the host star's illumination, and the observer's visibility of different planet regions. It is useful to treat the product of illumination and visibility as the kernel of a convolution; this kernel is unimodal and symmetric. For planets with unknown obliquity, the kernel is not known a priori, but could be inferred by fitting a rotational light curve. We analyze this kernel under different viewing geometries, finding it well described by its longitudinal width and latitudinal position. We use Monte Carlo simulation to estimate uncertainties on these kernel char...

  15. Solar Obliquity Induced by Planet Nine

    CERN Document Server

    Bailey, Elizabeth; Brown, Michael E

    2016-01-01

    The six-degree obliquity of the sun suggests that either an asymmetry was present in the solar system's formation environment, or an external torque has misaligned the angular momentum vectors of the sun and the planets. However, the exact origin of this obliquity remains an open question. Batygin & Brown (2016) have recently shown that the physical alignment of distant Kuiper Belt orbits can be explained by a 5-20 Earth-mass planet on a distant, eccentric, and inclined orbit, with an approximate perihelion distance of ~250 AU. Using an analytic model for secular interactions between Planet Nine and the remaining giant planets, here we show that a planet with similar parameters can naturally generate the observed obliquity as well as the specific pole position of the sun's spin axis, from a nearly aligned initial state. Thus, Planet Nine offers a testable explanation for the otherwise mysterious spin-orbit misalignment of the solar system.

  16. Dynamical Instabilities in High-Obliquity Systems

    CERN Document Server

    Tamayo, Daniel; Hamilton, Douglas P; Nicholson, Philip D

    2012-01-01

    High-inclination circumplanetary orbits that are gravitationally perturbed by the central star can undergo Kozai oscillations---large-amplitude, coupled variations in the orbital eccentricity and inclination. We first study how this effect is modified by incorporating perturbations from the planetary oblateness. Tremaine et al. (2009) found that, for planets with obliquities > 68.875 degrees, orbits in the equilibrium local Laplace plane are unstable to eccentricity perturbations over a finite radial range, and execute large-amplitude chaotic oscillations in eccentricity and inclination. In the hope of making that treatment more easily understandable, we analyze the problem using orbital elements, confirming this threshold obliquity. Furthermore, we find that orbits inclined to the Laplace plane will be unstable over a broader radial range, and that such orbits can go unstable for obliquities less than 68.875 degrees. Finally, we analyze the added effects of radiation pressure, which are important for dust gr...

  17. Effective operator contributions to the oblique parameters

    CERN Document Server

    Sánchez-Colón, G

    1998-01-01

    We present a model and process independent study of the contributions from non-Standard Model physics to the oblique parameters S, T and U. We show that within an effective lagrangian parameterization the expressions for the oblique parameters in terms of observables are consistent, while those in terms of the vector-boson vacuum polarization tensors are ambiguous. We obtain the constraints on the scale of new physics derived from current data on S, T and U and note that deviations in U from its Standard Model value would favor a scenario where the underlying physics does not decouple.

  18. Testing the IONORT-ISP system: a comparison between synthesized and measured oblique ionograms

    Science.gov (United States)

    Settimi, Alessandro; Pezzopane, Michael; Pietrella, Marco; Bianchi, Cesidio; Scotto, Carlo; Zuccheretti, Enrico; Maktris, John P.

    2013-04-01

    The three-dimensional (3-D) electron density representation of the ionosphere computed by the assimilative IRI-SIRMUP-P (ISP) model was tested using IONORT (IONOspheric Ray-Tracing), a software application for calculating a 3-D ray-tracing for high frequency (HF) waves in the ionospheric medium. A radio link was established between Rome (41.8°N, 12.5°E) in Italy, and Chania (35.7°N, 24.0°E) in Greece, within the ISP validity area, and for which oblique soundings are conducted. The ionospheric reference stations, from which the autoscaled foF2 and M(3000)F2 data and real-time vertical electron density profiles were assimilated by the ISP model, were Rome (41.8°N, 12.5°E) and Gibilmanna (37.9°N, 14.0°E) in Italy, and Athens (38.0°N, 23.5°E) in Greece. IONORT was used, in conjunction with the ISP and the International Reference Ionosphere (IRI) 3-D electron density grids, to synthesize oblique ionograms. The comparison between synthesized and measured oblique ionograms, both in terms of the ionogram shape and the maximum usable frequency characterizing the radio path, demonstrates both that the ISP model can more accurately represent real conditions in the ionosphere than the IRI, and that the ray-tracing results computed by IONORT are reasonably reliable.

  19. Ictal propagation of high frequency activity is recapitulated in interictal recordings: effective connectivity of epileptogenic networks recorded with intracranial EEG

    Science.gov (United States)

    Korzeniewska, A.; Cervenka, M.C.; Jouny, C.C.; Perilla, J.R.; Harezlak, J.; Bergey, G.K.; Franaszczuk, P.J.; Crone, N.E.

    2014-01-01

    Seizures are increasingly understood to arise from epileptogenic networks across which ictal activity is propagated and sustained. In patients undergoing invasive monitoring for epilepsy surgery, high frequency oscillations have been observed within the seizure onset zone during both ictal and interictal intervals. We hypothesized that the patterns by which high frequency activity is propagated would help elucidate epileptogenic networks and thereby identify network nodes relevant for surgical planning. Intracranial EEG recordings were analyzed with a multivariate autoregressive modeling technique (short-time direct directed transfer function - SdDTF), based on the concept of Granger causality, to estimate the directionality and intensity of propagation of high frequency activity (70–175 Hz) during ictal and interictal recordings. These analyses revealed prominent divergence and convergence of high frequency activity propagation at sites identified by epileptologists as part of the ictal onset zone. In contrast, relatively little propagation of this activity was observed among the other analyzed sites. This pattern was observed in both subdural and depth electrode recordings of patients with focal ictal onset, but not in patients with a widely distributed ictal onset. In patients with focal ictal onsets, the patterns of propagation recorded during pre-ictal (up to 5 minutes immediately preceding ictal onset) and interictal (more than 24 hours before and after seizures) intervals were very similar to those recorded during seizures. The ability to characterize epileptogenic networks from interictal recordings could have important clinical implications for epilepsy surgery planning by reducing the need for prolonged invasive monitoring to record spontaneous seizures. PMID:25003814

  20. Excitation and Ionisation dynamics in high-frequency plasmas

    Science.gov (United States)

    O'Connell, D.

    2008-07-01

    excitation and sustainment of the discharge. As the pressure decreases the discharge operates in so-called 'alpha-mode' where the sheath expansion is responsible for discharge sustainment. Decreasing the pressure towards the limit of operation (below 1 Pa) the discharge operates in a regime where kinetic effects dominate plasma sustainment. Wave particle interactions resulting from the flux of highly energetic electrons interacting with thermal bulk electrons give rise to a series of oscillations in the electron excitation phase space at the sheath edge. This instability is responsible for a significant energy deposit in the plasma when so-called 'ohmic heating' is no longer efficient. In addition to this an interesting electron acceleration mechanism occurs during the sheath collapse. The large sheath width, due to low plasma densities at the lower pressure, and electron inertia allows the build up of a local electric field accelerating electrons towards the electrode. Multi-frequency plasmas, provide additional process control for technological applications, and through investigating the excitation dynamics in such discharges the limitations of functional separation is observed. Non-linear frequency coupling is observed in plasma boundary sheaths governed by two frequencies simultaneously. In an alpha-operated discharge the sheath edge velocity governs the excitation and ionisation within the plasma, and it will be shown that this is determined by the time varying sheath width. The nature of the coupling effects strongly depends on the ratio of the applied voltages. Under technologically relevant conditions (low frequency voltage >> high frequency voltage) interesting phenomena depending on the phase relation of the voltages are also observed and will be discussed.

  1. Modeling of Polar Precipitation with CloudSat, AIRS and High Frequency Microwave Radiometers

    Science.gov (United States)

    Turk, F. J.; Park, K.; Wang, N.; Haddad, Z. S.

    2009-12-01

    While measuring and monitoring precipitation in polar regions is difficult, recent studies have shown that microwave radiances measured by operational high-frequency sounders, such as the Advanced Microwave Sounding Unit (AMSU) and the Microwave Humidity Sounder (MHS), are sensitive to falling snow, though the frozen surface makes it very difficult to retrieve snowfall rates from these radiometric measurements. Since the microwave sounding channels are sensitive to the variable surface emissivity, the crucial step was to classify these data according to fractional ice coverage (derived from AMSR-E) and use principal component analyses to further separate the variations due to the radiometric signatures of the precipitation from that of the surface. These results quantify the correlation between the higher principal components of the microwave radiances and the CloudSat radar reflectivity profile. Further radiative transfer modeling of the polar atmosphere is done using the AIRS temperature and moisture profiles to specify the background atmosphere. We relate the simulated microwave radiances to the near-surface precipitation itself, by considering several hydrometeor habit and size distributions and super-cooled cloud liquid fractions, performing reflectivity-to-snow-content retrievals from the CloudSat radar profiles of ice and liquid water content.. With this methodology, one can simulate polar precipitation observations systematically utilizing these time/space matched measurements from the CloudSat radar and polar-orbiting high-frequency radiometers such as MHS or the SSMIS. In turn, this will help evaluate the realism of numerical models and their microphysical assumptions, particularly as the latter appear to have significant difficulties representing Arctic clouds accurately.

  2. Long range ultra-high frequency (UHF) radio frequency identification (RFID) antenna design

    Science.gov (United States)

    Reynolds, Nathan D.

    There is an ever-increasing demand for radio frequency identification (RFID) tags that are passive, long range, and mountable on multiple surfaces. Currently, RFID technology is utilized in numerous applications such as supply chain management, access control, and public transportation. With the combination of sensory systems in recent years, the applications of RFID technology have been extended beyond tracking and identifying. This extension includes applications such as environmental monitoring and healthcare applications. The available sensory systems usually operate in the medium or high frequency bands and have a low read range. However, the range limitations of these systems are being overcome by the development of RFID sensors focused on utilizing tags in the ultra-high frequency (UHF) band. Generally, RFID tags have to be mounted to the object that is being identified. Often the objects requiring identification are metallic. The inherent properties of metallic objects have substantial effects on nearby electromagnetic radiation; therefore, the operation of the tag antenna is affected when mounted on a metallic surface. This outlines one of the most challenging problems for RFID systems today: the optimization of tag antenna performance in a complex environment. In this research, a novel UHF RFID tag antenna, which has a low profile, long range, and is mountable on metallic surfaces, is designed analytically and simulated using a 3-D electromagnetic simulator, ANSYS HFSS. A microstrip patch antenna is selected as the antenna structure, as patch antennas are low profile and suitable for mounting on metallic surfaces. Matching and theoretical models of the microstrip patch antenna are investigated. Once matching and theory of a microstrip patch antenna is thoroughly understood, a unique design technique using electromagnetic band gap (EBG) structures is explored. This research shows that the utilization of an EBG structure in the patch antenna design yields

  3. A continuously weighing, high frequency sand trap: Wind tunnel and field evaluations

    Science.gov (United States)

    Yang, Fan; Yang, XingHua; Huo, Wen; Ali, Mamtimin; Zheng, XinQian; Zhou, ChengLong; He, Qing

    2017-09-01

    A new continuously weighing, high frequency sand trap (CWHF) has been designed. Its sampling efficiency is evaluated in a wind tunnel and the potential of the new trap has been demonstrated in field trials. The newly designed sand trap allows fully automated and high frequency measurement of sediment fluxes over extensive periods. We show that it can capture the variations and structures of wind-driven sand transport processes and horizontal sediment flux, and reveal the relationships between sand transport and meteorological parameters. Its maximum sampling frequency can reach 10 Hz. Wind tunnel tests indicated that the sampling efficiency of the CWHF sand trap varies between 39.2 to 64.3%, with an average of 52.5%. It achieved a maximum sampling efficiency of 64.3% at a wind speed of 10 m s- 1. This is largely achieved by the inclusion of a vent hole which leads to a higher sampling efficiency than that of a step-like sand trap at high wind speeds. In field experiments, we show a good agreement between the mass of sediment from the CWHF sand trap, the wind speed at 2 m and the number of saltating particles at 5 cm above the ground surface. According to analysis of the horizontal sediment flux at four heights from the CWHF sand trap (25, 35, 50, and 100 cm), the vertical distribution of the horizontal sediment flux up to a height of 100 cm above the sand surface follows an exponential function. Our field experiments show that the new instrument can capture more detailed information on sediment transport with much reduced labor requirement. Therefore, it has great potential for application in wind-blown sand monitoring and process studies.

  4. Multiscale bloom dynamics from a high frequency autonomous measurement system in the Eastern English Channel

    Science.gov (United States)

    Derot, Jonathan; Schmitt, François; Gentilhomme, Valérie

    2014-05-01

    We consider here a dataset from an Eulerian automated system, located on the coastal area of the French side of the English Channel (Boulogne-sur-Mer), called MAREL Carnot, operated by IFREMER (France). This system records more than 15 physico-chemical parameters at 20 minutes intervals, and at the constant depth of -1,5m whatever the tidal range. Our study focuses on the period 2004 to 2011. The objective of this study is to have a better understanding of the bloom fluorescence multiscale dynamics, as regards the coastal area of English Channel and possible influence of temperature on this dynamics. Annual blooms are visible, superposed to multiscale fluctuations. The probability density function (PDF) of the fluorescence time series very nicely obeys a power law with slope -2. The PDF for annual portions obeys also power laws, with slopes which are related to the annual average. Empirical mode decomposition (EMD) is used to study the dynamics and display the power spectrum, which will be linked with these dynamics. EMD method is also used to extract a trend and isolate the blooms from the high frequency dynamics. We show that the high frequency part of the fluorescence dynamics has a very large variance during bloom events, compared to normal conditions. We also show that there is a link between the mean winter temperature and the strength of bloom next spring. These results contribute to statistically characterize the bloom dynamics and extract some possible universal relations. Keywords: English Channel; Autonomous monitoring; Power spectra; EMD method; Probability density functions; Power laws.

  5. High frequency oscillations mirror disease activity in patients with focal cortical dysplasia.

    Science.gov (United States)

    Kerber, Karolin; LeVan, Pierre; Dümpelmann, Matthias; Fauser, Susanne; Korinthenberg, Rudolf; Schulze-Bonhage, Andreas; Jacobs, Julia

    2013-08-01

    The study analyzes the occurrence of high frequency oscillations in different types of focal cortical dysplasia in 22 patients with refractory epilepsy. High frequency oscillations are biomarkers for epileptic tissue, but it is unknown whether they can reflect increasingly dysplastic tissue changes as well as epileptic disease activity. High frequency oscillations (80-450 Hz) were visually marked by two independent reviewers in all channels of intracranial implanted grid, strips, and depth electrodes in patients with focal cortical dysplasia and refractory epilepsy. Rates of high frequency oscillations in patients with pathologically confirmed focal cortical dysplasia of Palmini type 1a and b were compared with those in type 2a and b. Patients with focal cortical dysplasia type 2 had significantly more seizures than those with type 1 (p high frequency oscillations were significantly higher in patients with focal cortical dysplasia type 2 versus type 1 (p high frequency oscillations were significantly higher in presumed epileptogenic areas than outside (p high frequency oscillations mirrors the higher epileptogenicity of focal cortical dysplasia type 2 lesions compared to type 1 lesions. Therefore, rates of high frequency oscillations can reflect disease activity of a lesion. This has implications for the use of high frequency oscillations as biomarkers for epileptogenic areas, because a detailed analysis of their rates may be necessary to use high frequency oscillations as a predictive tool in epilepsy surgery. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.

  6. High Frequency Active Auroral Research Program (HAARP) Imager

    Science.gov (United States)

    1993-09-30

    Step: [’I Bin: 7 0 AutoBin 0 A:ROl There are two parameters that control the histogram that can be changed. Step size, and Bin size. Step size refers to...etc. This will also greatly increase the speed of histogram execution. The AutoBin checkbox allows the MIPCTL application to determine the optimum...horizontal resolution of our monitors is 1024 pixels, a normal histogram would be 1024 points. The AutoBin calculates this binning factor: For the 16

  7. Oblique Du-Fort Frankel Beam Propagation Method

    Directory of Open Access Journals (Sweden)

    Ken Chan

    2011-01-01

    Full Text Available The oblique BPM based on the Du-Fort Frankel method is presented. The paper demonstrates the accuracy and the computational improvements of the scheme compared to the oblique BPM based on Crank-Nicholson (CN scheme.

  8. Formation of transverse waves in oblique detonations

    NARCIS (Netherlands)

    Verreault, J.; Higgins, A.J.; Stowe, R.A.

    2013-01-01

    The structure of oblique detonation waves stabilized on a hypersonic wedge in mixtures characterized by a large activation energy is investigated via steady method of characteristics (MoC) calculations and unsteady computational flowfield simulations. The steady MoC solutions show that, after the tr

  9. Orientation Strategies for Aerial Oblique Images

    Science.gov (United States)

    Wiedemann, A.; Moré, J.

    2012-07-01

    Oblique aerial images become more and more distributed to fill the gap between vertical aerial images and mobile mapping systems. Different systems are on the market. For some applications, like texture mapping, precise orientation data are required. One point is the stable interior orientation, which can be achieved by stable camera systems, the other a precise exterior orientation. A sufficient exterior orientation can be achieved by a large effort in direct sensor orientation, whereas minor errors in the angles have a larger effect than in vertical imagery. The more appropriate approach is by determine the precise orientation parameters by photogrammetric methods using an adapted aerial triangulation. Due to the different points of view towards the object the traditional aerotriangulation matching tools fail, as they produce a bunch of blunders and require a lot of manual work to achieve a sufficient solution. In this paper some approaches are discussed and results are presented for the most promising approaches. We describe a single step approach with an aerotriangulation using all available images; a two step approach with an aerotriangulation only of the vertical images plus a mathematical transformation of the oblique images using the oblique cameras excentricity; and finally the extended functional model for a bundle block adjustment considering the mechanical connection between vertical and oblique images. Beside accuracy also other aspects like efficiency and required manual work have to be considered.

  10. Flow and sediment transport across oblique channels

    DEFF Research Database (Denmark)

    Hjelmager Jensen, Jacob; Madsen, Erik Østergaard; Fredsøe, Jørgen

    1998-01-01

    A 3D numerical investigation of flow across channels aligned obliquely to the main flow direction has been conducted. The applied numerical model solves the Reynolds-averaged Navier-Stokes equations using the k-ε model for turbulence closure on a curvilinear grid. Three momentum equations are sol...

  11. Oblique patterned etching of vertical silicon sidewalls

    Science.gov (United States)

    Bruce Burckel, D.; Finnegan, Patrick S.; David Henry, M.; Resnick, Paul J.; Jarecki, Robert L.

    2016-04-01

    A method for patterning on vertical silicon surfaces in high aspect ratio silicon topography is presented. A Faraday cage is used to direct energetic reactive ions obliquely through a patterned suspended membrane positioned over the topography. The technique is capable of forming high-fidelity pattern (100 nm) features, adding an additional fabrication capability to standard top-down fabrication approaches.

  12. Obliquity Modulation of the Incoming Solar Radiation

    Science.gov (United States)

    Liu, Han-Shou; Smith, David E. (Technical Monitor)

    2001-01-01

    Based on a basic principle of orbital resonance, we have identified a huge deficit of solar radiation induced by the combined amplitude and frequency modulation of the Earth's obliquity as possibly the causal mechanism for ice age glaciation. Including this modulation effect on solar radiation, we have performed model simulations of climate change for the past 2 million years. Simulation results show that: (1) For the past 1 million years, temperature fluctuation cycles were dominated by a 100-Kyr period due to amplitude-frequency resonance effect of the obliquity; (2) From 2 to 1 million years ago, the amplitude-frequency interactions. of the obliquity were so weak that they were not able to stimulate a resonance effect on solar radiation; (3) Amplitude and frequency modulation analysis on solar radiation provides a series of resonance in the incoming solar radiation which may shift the glaciation cycles from 41-Kyr to 100-Kyr about 0.9 million years ago. These results are in good agreement with the marine and continental paleoclimate records. Thus, the proposed climate response to the combined amplitude and frequency modulation of the Earth's obliquity may be the key to understanding the glaciation puzzles in paleoclimatology.

  13. Formation of transverse waves in oblique detonations

    NARCIS (Netherlands)

    Verreault, J.; Higgins, A.J.; Stowe, R.A.

    2013-01-01

    The structure of oblique detonation waves stabilized on a hypersonic wedge in mixtures characterized by a large activation energy is investigated via steady method of characteristics (MoC) calculations and unsteady computational flowfield simulations. The steady MoC solutions show that, after the tr

  14. Insolation patterns on synchronous exoplanets with obliquity

    Science.gov (United States)

    Dobrovolskis, Anthony R.

    2009-11-01

    A previous paper [Dobrovolskis, A.R., 2007. Icarus 192, 1-23] showed that eccentricity can have profound effects on the climate, habitability, and detectability of extrasolar planets. This complementary study shows that obliquity can have comparable effects. The known exoplanets exhibit a wide range of orbital eccentricities, but those within several million kilometers of their suns are generally in near-circular orbits. This fact is widely attributed to the dissipation of tides in the planets. Tides in a planet affect its spin even more than its orbit, and such tidally evolved planets often are assumed to be in synchronous rotation, so that their rotation periods are identical to their orbital periods. The canonical example of synchronous spin is the way that our Moon always keeps nearly the same hemisphere facing the Earth. Tides also tend to reduce the planet's obliquity (the angle between its spin and orbital angular velocities). However, orbit precession can cause the rotation to become locked in a "Cassini state", where it retains a nearly constant non-zero obliquity. For example, our Moon maintains an obliquity of about 6.7° with respect to its orbit about the Earth. In comparison, stable Cassini states can exist for practically any obliquity up to ˜90° or more for planets of binary stars, or in multi-planet systems with high mutual inclinations, such as are produced by scattering or by the Kozai mechanism. This work considers planets in synchronous rotation with circular orbits, but arbitrary obliquity β; this affects the distribution of insolation over the planet's surface, particularly near its poles. For β=0, one hemisphere bakes in perpetual sunshine, while the opposite hemisphere experiences eternal darkness. As β increases, the region of permanent daylight and the antipodal realm of endless night both shrink, while a more temperate area of alternating day and night spreads in longitude, and especially in latitude. The regions of permanent day or

  15. Design of High Frequency Power Oscillator Board Based on Rotary Encoder Control

    Directory of Open Access Journals (Sweden)

    Jiang Shifen

    2013-06-01

    Full Text Available Accurate and stable high frequency pulse power supply is studied to improve high-speed wedm machine tool's efficiency. Regarding to the shortcomings of traditional digital circuit high frequency oscillator board, we design a high frequency power oscillator board based on rotary encoder control, control accuracy and high-frequency waveform by programming, adjusting the frequency and display. It has six brakes of processing function, it also includes feedback function of emulsification oil. The high frequency will be shutdown and the emulsification oil will be changed if there is too much metal dust in emulsification. It has been proved by practice that high-frequency circuit board is simple and reliable and can greatly increase efficiency of wire cutting.

  16. A New High Frequency Injection Method Based on Duty Cycle Shifting without Maximum Voltage Magnitude Loss

    DEFF Research Database (Denmark)

    Wang, Dong; Lu, Kaiyuan; Rasmussen, Peter Omand

    2015-01-01

    The conventional high frequency signal injection method is to superimpose a high frequency voltage signal to the commanded stator voltage before space vector modulation. Therefore, the magnitude of the voltage used for machine torque production is limited. In this paper, a new high frequency...... injection method, in which high frequency signal is generated by shifting the duty cycle between two neighboring switching periods, is proposed. This method allows injecting a high frequency signal at half of the switching frequency without the necessity to sacrifice the machine fundamental voltage...... amplitude. This may be utilized to develop new position estimation algorithm without involving the inductance in the medium to high speed range. As an application example, a developed inductance independent position estimation algorithm using the proposed high frequency injection method is applied to drive...

  17. Magnetoencephalography detection of high-frequency oscillations in the developing brain.

    Science.gov (United States)

    Leiken, Kimberly; Xiang, Jing; Zhang, Fawen; Shi, Jingping; Tang, Lu; Liu, Hongxing; Wang, Xiaoshan

    2014-01-01

    Increasing evidence from invasive intracranial recordings suggests that the matured brain generates both physiological and pathological high-frequency signals. The present study was designed to detect high-frequency brain signals in the developing brain using newly developed magnetoencephalography (MEG) methods. Twenty healthy children were studied with a high-sampling rate MEG system. Functional high-frequency brain signals were evoked by electrical stimulation applied to the index fingers. To determine if the high-frequency neuromagnetic signals are true brain responses in high-frequency range, we analyzed the MEG data using the conventional averaging as well as newly developed time-frequency analysis along with beamforming. The data of healthy children showed that very high-frequency brain signals (>1000 Hz) in the somatosensory cortex in the developing brain could be detected and localized using MEG. The amplitude of very high-frequency brain signals was significantly weaker than that of the low-frequency brain signals. Very high-frequency brain signals showed a much earlier latency than those of a low-frequency. Magnetic source imaging (MSI) revealed that a portion of the high-frequency signals was from the somatosensory cortex, another portion of the high-frequency signals was probably from the thalamus. Our results provide evidence that the developing brain generates high-frequency signals that can be detected with the non-invasive technique of MEG. MEG detection of high-frequency brain signals may open a new window for the study of developing brain function.

  18. Sonic analogue of black holes and the effects of high frequencies on black hole evaporation

    CERN Document Server

    Unruh, W G

    1995-01-01

    The naive calculation of black hole evaporation makes the thermal emission depend on the arbitrary high frequency behaviour of the theory where the theory is certainly wrong. Using the sonic analog to black holes-- dumb holes-- I show numerically that a change in the dispersion relation at high frequencies does not seem to alter the evaporation process, lending weight to the reality of the black hole evaporation process. I also suggest a reason for the insensitivity of the process to high frequency regime.

  19. Analysis of Energy Overshoot of High Frequency Waves with Wavelet Transform

    Institute of Scientific and Technical Information of China (English)

    WEN Fan

    2000-01-01

    A study is made on the overshoot phenomena in wind-generated waves. The surface displace ments of time-growing waves are measured at four fetches in a wind wave channel. The evolution of high frequency waves is displayed with wavelet transform. The results are compared with Sutherland's. It is found that high frequency wave components experience much stronger energy overshoot in the evolution.The energy of high frequency waves decreases greatly after overshoot

  20. High Frequency Excitation for Cavity Flow Control: Combined Experiments and Linear Stability Analysis

    Science.gov (United States)

    2009-06-30

    Peto , "Suppression of cav- ity resonance using high frequency forcing - the characteristic signature of effective devices", American Institute of...Aeronautics and Astronautics Paper 2001-2128 (2001). 25 M. Stanek, G. Raman, J. A. Ross, J. Odedra, J. W. Peto , F. Alvi, and V. Kibens, "High frequency...Institute of Aeronautics and 30 Astronautics Paper 2002-2404 (2002). 26 M. Stanek, J. A. Ross, J. Odedra, and J. Peto , "High frequency acoustic

  1. Oblique effect in visual mismatch negativity

    Directory of Open Access Journals (Sweden)

    Endre eTakács

    2013-09-01

    Full Text Available We investigated whether visual orientation anisotropies (known as oblique effect exist in non-attended visual changes using event-related potentials (ERP. We recorded visual mismatch negativity (vMMN which signals violation of sequential regularities. In the visual periphery unattended, task-irrelevant Gábor patches were displayed in an oddball sequence while subjects performed a tracking task in the central field. A moderate change (50° in the orientation of stimuli revealed no consistent change-related components. However we found orientation-related differences around 170 ms in occipito-temporal areas in the amplitude of the ERPs evoked by standard stimuli. In a supplementary experiment we determined the amount of orientation difference that is needed for change detection in an active, attended paradigm. Results exhibited the classical oblique effect; subjects detected 10° deviations from cardinal directions, while threshold from oblique directions was 17°. These results provide evidence that perception of change could be accomplished at significantly smaller thresholds, than what elicits vMMN. In Experiment2 we increased the orientation change to 90°. Deviant-minus-standard difference was negative in occipito-parietal areas, between 120-200 ms after stimulus onset. VMMNs to changes from cardinal angles were larger and more sustained than vMMNs evoked by changes from oblique angles. Changes from cardinal orientations represent a more detectable signal for the automatic change detection system than changes from oblique angles, thus increased vMMN to these larger deviances might be considered a variant of the magnitude of deviance effect rarely observed in vMMN studies.

  2. The Chicxulub Impact Crater and Oblique Impact

    Science.gov (United States)

    McDonald, M.; Gulick, S.; Melosh, H.; Christeson, G.

    2007-05-01

    Determining whether or not the Chicxulub impact was oblique (<45 degrees) will aid in our understanding of the environmental consequences 65 Ma. Planetary impact events, and impact simulations in the laboratory, show that oblique impacts have clear asymmetric ejecta distributions. However, the subsurface structures of the resultant craters are not well understood. In 2005, we acquired 1822 km of seismic reflection data onboard the R/V Maurice Ewing imaging the massive (200+ km) Chicxulub impact crater. The seismic profiles show that pre- crater stratigraphy outside the central basin of the Chicxulub impact crater is offset downward into the crater marking the post-impact slumping and formation of the terrace zone. The inward collapse of the Chicxulub terrace zone coincides with the outward collapse of the central uplift to form the peak ring. Chicxulub's peak ring is offset to the southeast, away from the deepest terrace zone mapped in the seismic data, suggesting that its peak ring was offset toward a more gradual wall of the transient cavity. Peak ring offsets, relative to crater center, of Venusian craters from radar images in the Magellan data set allow us to determine whether there are systematic variations in peak ring offset due to oblique impact. Ten pristine Venusian peak ring craters formed by oblique impact show that peak rings are offset both uprange and downrange, suggesting that peak ring position, and related subsurface asymmetries in the terrace zone, do not provide information about impact obliquity. This analysis supports the idea that Chicxulub's peak ring offset is a consequence of target properties and pre-impact structure and independent of impact trajectory.

  3. Study of a Particle Based Films Cure Process by High-Frequency Eddy Current Spectroscopy

    Directory of Open Access Journals (Sweden)

    Iryna Patsora

    2016-12-01

    Full Text Available Particle-based films are today an important part of various designs and they are implemented in structures as conductive parts, i.e., conductive paste printing in the manufacture of Li-ion batteries, solar cells or resistive paste printing in IC. Recently, particle based films were also implemented in the 3D printing technique, and are particularly important for use in aircraft, wind power, and the automotive industry when incorporated onto the surface of composite structures for protection against damages caused by a lightning strike. A crucial issue for the lightning protection area is to realize films with high homogeneity of electrical resistance where an in-situ noninvasive method has to be elaborated for quality monitoring to avoid undesirable financial and time costs. In this work the drying process of particle based films was investigated by high-frequency eddy current (HFEC spectroscopy in order to work out an automated in-situ quality monitoring method with a focus on the electrical resistance of the films. Different types of particle based films deposited on dielectric and carbon fiber reinforced plastic substrates were investigated in the present study and results show that the HFEC method offers a good opportunity to monitor the overall drying process of particle based films. Based on that, an algorithm was developed, allowing prediction of the final electrical resistance of the particle based films throughout the drying process, and was successfully implemented in a prototype system based on the EddyCus® HFEC device platform presented in this work. This prototype is the first solution for a portable system allowing HFEC measurement on huge and uneven surfaces.

  4. High-frequency low-level diode laser irradiation promotes proliferation and migration of primary cultured human gingival epithelial cells.

    Science.gov (United States)

    Ejiri, Kenichiro; Aoki, Akira; Yamaguchi, Yoko; Ohshima, Mitsuhiro; Izumi, Yuichi

    2014-07-01

    In periodontal therapy, the use of low-level diode lasers has recently been considered to improve wound healing of the gingival tissue. However, its effects on human gingival epithelial cells (HGECs) remain unknown. The aim of the present study was to examine whether high-frequency low-level diode laser irradiation stimulates key cell responses in wound healing, proliferation and migration, in primary cultured HGECs in vitro. HGECs were derived from seven independent gingival tissue specimens. Cultured HGECs were exposed to a single session of high-frequency (30 kHz) low-level diode laser irradiation with various irradiation time periods (fluence 5.7-56.7 J/cm(2)). After 20-24 h, cell proliferation was evaluated by WST-8 assay and [(3)H]thymidine incorporation assay, and cell migration was monitored by in vitro wound healing assay. Further, phosphorylation of the mitogen-activated protein kinase (MAPK) pathways after irradiation was investigated by Western blotting. The high-frequency low-level irradiation significantly increased cell proliferation and [(3)H]thymidine incorporation at various irradiation time periods. Migration of the irradiated cells was significantly accelerated compared with the nonirradiated control. Further, the low-level diode laser irradiation induced phosphorylation of MAPK/extracellular signal-regulated protein kinase (ERK) at 5, 15, 60, and 120 min after irradiation. Stress-activated protein kinases/c-Jun N-terminal kinase and p38 MAPK remained un-phosphorylated. The results show that high-frequency low-level diode laser irradiation promotes HGEC proliferation and migration in association with the activation of MAPK/ERK, suggesting that laser irradiation may accelerate gingival wound healing.

  5. Inferior oblique weakening surgery on ocular torsion in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Jinho Lee

    2015-06-01

    Full Text Available AIM:To investigate changes in fundus excyclotorsion after inferior oblique myectomy or myotomy.METHODS:The records of 21 patients undergoing strabismus surgery by a single surgeon between 2009 and 2012 were examined. Only patients who had undergone an inferior oblique myectomy or myotomy, with or without horizontal rectus muscle surgery, were evaluated. Digital fundus photographs were obtained, and the angle formed by a horizontal line passing through the optic disc center and a reference line connecting the foveola and optic disc center was measured. Associated clinical factors examined include age at the time of surgery, presence or absence of a head tilt, degree of preoperative vertical deviation, torsional angle, inferior oblique muscle overaction/superior oblique muscle underaction, and surgery laterality. Whether the procedure was performed alone or in combination with a horizontal rectus muscle surgery was also examined.RESULTS:Mean preoperative torsional angle was 12.0±6.4°, which decreased to 6.9±5.7° after surgery (P<0.001, paired t-test. Torsional angle also decreased from 15.1±7.0° to 6.2±4.3° in the myectomy group (P<0.001, paired t-test but there were no significant changes in the myotomy group (P=0.093, Wilcoxon signed rank test. Multivariable linear regression analysis showed that preoperative torsional angle, degree of inferior oblique overaction, and age at surgery independently and significantly affected postoperative torsional angle.CONCLUSION:Mean torsional angle decreased after inferior oblique myectomy. Degree of preoperative torsional angle, inferior oblique overaction, and age at surgery influence postoperative torsional angle.

  6. Does Phonology Play a Role When Skilled Readers Read High-Frequency Words? Evidence from ERPs

    Science.gov (United States)

    Newman, Randy Lynn; Jared, Debra; Haigh, Corinne A.

    2012-01-01

    We used event-related brain potentials to clarify the role of phonology in activating the meanings of high-frequency words during skilled silent reading. Target homophones ("meet") in sentences such as "The students arranged to meet in the library to study" were replaced on some trials by either a high-frequency homophone mate…

  7. High frequency electromagnetic processes in induction motors supplied from PWM inverters

    Directory of Open Access Journals (Sweden)

    Ioan Ţilea

    2010-12-01

    Full Text Available The paper presents the electromagnetic interference between induction motors and inverters when at high frequency electromagnetic process appears in induction motors having a parallel resonant effect because of parasitic capacitive coupling between windings and ground, using a numerical model in simulink and a high frequency induction motor equivalent circuit model this effect is shown.

  8. Influence of X-ray and polar cap absorptions on vertical and oblique sounding ionograms on different latitudes

    Science.gov (United States)

    Zaalov, N. Y.; Moskaleva, E. V.; Rogov, D. D.; Zernov, N. N.

    2015-12-01

    High frequency (HF) radio band is important for the long-range communications and over-the-horizon surveillance, particularly in the polar cap region where the ground infrastructure may be limited. However, the space weather events drastically affect the high frequency radio wave propagation so that the ability to provide now-casting and forecasting of HF radio wave absorption is important for users relying on the HF communications. During the space weather events such as solar proton events and X-ray flares the high-latitude ionosphere becomes a particularly efficient absorber of HF radio waves. There is therefore a need to develop accurate HF propagation prediction services. Absorption of the HF field caused by the X-ray flux, Solar Ultra-Violet flux and proton precipitations is investigated in this paper for the event of the solar flare observed on 11 April 2013. The effects of the X-ray flux and proton precipitations on the structure of the vertical and oblique ionograms for different latitudes are estimated. The simulation of the vertical and oblique ionograms was performed on the basis of the computational model of the ionosphere oriented to applications into the high frequency wave propagation problems. The absorption effects induced by the proton precipitations and X-ray flux are calculated according to the algorithm elaborated by Sauer and Wilkinson and D-region Absorption Model (D-RAP) available from the NOAA Space Weather Prediction Center. The simulated vertical and oblique ionograms with the absorption effects taken into account and the measured ionograms exhibit a fairly good similarity.

  9. Proton beam generation of oblique whistler waves

    Science.gov (United States)

    Wong, H. K.; Goldstein, M. L.

    1988-01-01

    It is known that ion beams are capable of generating whistler waves that propagate parallel to the mean magnetic field. Such waves may have been observed both upstream of the earth's bow shock and in the vicinity of comets. Previous analyses are extended to include propagation oblique to the mean magnetic field. The instability is generated by the perpendicular component of free energy in the ions, which can arise either via a temperature anisotropy or via a gyrating distribution. In the former case, the generation of whistler waves is confined to a fairly narrow cone of propagation directions centered about parallel propagation; in the latter case, the maximum growth of the instability can occur at fairly large obliquities (theta equal to about 50 deg).

  10. Obliquely propagating dust-density waves

    Science.gov (United States)

    Piel, A.; Arp, O.; Klindworth, M.; Melzer, A.

    2008-02-01

    Self-excited dust-density waves are experimentally studied in a dusty plasma under microgravity. Two types of waves are observed: a mode inside the dust volume propagating in the direction of the ion flow and another mode propagating obliquely at the boundary between the dusty plasma and the space charge sheath. The dominance of oblique modes can be described in the frame of a fluid model. It is shown that the results fom the fluid model agree remarkably well with a kinetic electrostatic model of Rosenberg [J. Vac. Sci. Technol. A 14, 631 (1996)]. In the experiment, the instability is quenched by increasing the gas pressure or decreasing the dust density. The critical pressure and dust density are well described by the models.

  11. High frequency rTMS; a more effective treatment for auditory verbal hallucinations?

    Science.gov (United States)

    de Weijer, Antoin D; Sommer, Iris E C; Lotte Meijering, Anne; Bloemendaal, Mirjam; Neggers, Sebastiaan F W; Daalman, Kirstin; Boezeman, Eduard H J F

    2014-12-30

    The great majority of studies on repetitive transcranial magnetic stimulation (rTMS) as a therapeutic tool for auditory verbal hallucinations (AVH) have used 1-Hz stimulation with inconsistent results. Recently, it has been suggested that 20-Hz rTMS has strong therapeutic effects. It is conceivable that this 20-Hz stimulation is more effective than 1-Hz stimulation. The aim of this preliminary study is to investigate the efficacy of 20-Hz rTMS compared with 1-Hz rTMS as a treatment for AVH. Eighteen schizophrenia patients with medication-resistant AVH were randomized over two treatment groups. Each group received either 20 min of 1-Hz rTMS or 13 trains of 20-Hz rTMS daily over 1 week. After week 1, patients received a follow-up treatment once a week for 3 weeks. Stimulation location was based on individual AVH-related activation patterns identified with functional magnetic resonance imaging. Severity of AVH was monitored with the Auditory Hallucination Rating Scale (AHRS). Both groups showed a decrease in AVH after week 1 of rTMS. This decrease was significant for the 20-Hz group and the 1-Hz group. When the two treatment types were compared, no treatment type was superior. Based on these results we cannot conclude whether high frequency rTMS is more effective against AVH than is traditional 1-Hz rTMS. More research is needed to optimize stimulation parameters and to investigate potential target locations for stimulation.

  12. Development of a Flow Injection Based High Frequency Dual Channel Quartz Crystal Microbalance.

    Science.gov (United States)

    Liang, Jinxing; Zhang, Jing; Zhou, Wenxiang; Ueda, Toshitsugu

    2017-05-16

    When the quartz crystal microbalance (QCM) is used in liquid for adsorption or desorption monitoring based bio- or chemical sensing applications, the frequency shift is not only determined by the surface mass change, but also by the change of liquid characteristics, such as density and viscosity, which are greatly affected by the liquid environmental temperature. A monolithic dual-channel QCM is designed and fabricated by arranging two QCM resonators on one single chip for cancelling the fluctuation induced by environmental factors. In actual applications, one QCM works as a specific sensor by modifying with functional membranes and the other acts as a reference, only measuring the liquid property. The dual-channel QCM is designed with an inverted-mesa structure, aiming to realize a high frequency miniaturized chip and suppress the frequency interference between the neighbored QCM resonators. The key problem of dual-channel QCMs is the interference between two channels, which is influenced by the distance of adjacent resonators. The diameter of the reference electrode has been designed into several values in order to find the optimal parameter. Experimental results demonstrated that the two QCMs could vibrate individually and the output frequency stability and drift can be greatly improved with the aid of the reference QCM.

  13. Application of high-frequency ultrasound for the detection of surgical anatomy in the rodent abdomen.

    Science.gov (United States)

    Chen, J Y; Chen, H L; Wu, S H; Tsai, T C; Lin, M F; Yen, C C; Hsu, W H; Chen, W; Chen, C M

    2012-02-01

    Rats are used extensively in abdominal disease research. To monitor disease progress in vivo, high-frequency ultrasound (HFU) can be a powerful tool for obtaining high-resolution images of biological tissues. However, there is a paucity of data regarding the correlation between rat anatomy and corresponding HFU images. Twenty-four adult male Sprague-Dawley (SD) rats underwent abdominal scans using HFU (40 MHz) surgical procedures to identify abdominal organs and major vessels as well as in situ scanning to confirm the imaging results. The results were compared with those of human abdominal organs in ultrasonographic scans. The rat liver, paired kidneys, stomach, intestines, and major blood vessels were identified by HFU and the ultrasonic morphologies of the liver and kidneys showed clear differences between rats and humans. Clinically relevant anatomical structures were identified using HFU imaging of the rat abdomen, and these structures were compared with the corresponding structures in humans. Increased knowledge with regard to identifying the anatomy of rat abdominal organs by ultrasound will allow scientists to conduct more detailed intra-abdominal research in rodents.

  14. Scaling analysis of high-frequency time series of gamma-ray counts

    Science.gov (United States)

    Barbosa, Susana; Azevedo, Eduardo

    2017-04-01

    Gamma radiation is being monitored in a dedicated campaign set-up at the Eastern North Atlantic (ENA) facility located in the Graciosa island (Azores), a fixed site of the Atmospheric Radiation Measurement programme (ARM), established and supported by the Department of Energy (DOE) of the United States of America with the collaboration of the Government of the Autonomous Region of the Azores and University of the Azores. The temporal variability of gamma radiation is mainly determined by the time-varying concentration of radon progeny, which in turn is influenced by meteorological conditions and precipitation scavenging. The resulting time series of high-frequency (1-minute) gamma-ray counts displays therefore a complex temporal structure on multiple time scales, including long-range dependent behavior. This work addresses the scaling properties of the time series of gamma-ray counts from the ENA site (data freely available from the ARM data archive) using both wavelet and model-based methods for the estimation of the scaling exponent. The time series is dominated by sharp peaks associated with events of strong precipitation. The effect of these peaks on the estimation of the scaling exponent, as well as the effect of temporal aggregation (1-minute versus 15-minute aggregated data) is further addressed.

  15. Developing high-frequency ultrasound tomography for testicular tumor imaging in rats: An in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chih-Chung, E-mail: cchuang@mail.ncku.edu.tw [Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (China); Chen, Wei-Tsen [Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City 24205, Taiwan (China)

    2014-01-15

    Purpose: This paper describes a feasibility study for developing a 35-MHz high-frequency ultrasound computed-tomography (HFUCT) system for imaging rat testicles. Methods: The performances of two kinds of HFUCT-attenuation and sound-speed UCT-based on transmission and pulse-echo modes were investigated in this study. Experiments were carried out using phantoms and actual rat testiclesin vitro. HFUCT images were reconstructed using a filtered backprojection algorithm. Results: The phantom experimental results indicated that all types of HFUCT can determine the dimensions of a plastic cylinder with a diameter of 500μm. Compared to sound-speed HFUCT, attenuation HFUCT exhibited a better performance in recognizing a tiny sclerosed region in a gelatin phantom. Therefore, the in vitro testicular experiments were performed using attenuation HFUCT based on transmission and pulse-echo modes. The experimentally measured attenuation coefficient and sound speed for healthy rat testicles were 2.92 ± 0.25 dB/mm and 1537 ± 25 m/s, respectively. Conclusions: A homogeneous texture was evident for healthy testicles using both modes. An artificial sclerosed tumor could also be clearly observed using two- and three-dimensional attenuation HFUCT in both modes. However, an object artifact was apparent in pulse-echo mode because of ultrasound beam refraction. All of the obtained experimental results indicate the potential of using HFUCT as a novel tool for monitoring the preclinical responses of testicular tumors in small animals.

  16. Multi-year high-frequency physical and environmental observations at the Guadiana Estuary

    Science.gov (United States)

    Garel, E.; Ferreira, Ó.

    2015-11-01

    High-frequency data collected continuously over a multi-year time frame are required for investigating the various agents that drive ecological and hydrodynamic processes in estuaries. Here, we present water quality and current in situ observations from a fixed monitoring station operating from 2008 to 2014 in the lower Guadiana Estuary, southern Portugal (37°11.30' N, 7°24.67' W). The data were recorded by a multi-parametric probe providing hourly records (temperature, salinity, chlorophyll, dissolved oxygen, turbidity, and pH) at a water depth of ~ 1 m, and by a bottom-mounted acoustic Doppler current profiler measuring the pressure, near-bottom temperature, and flow velocity through the water column every 15 min. The time series data, in particular the probe ones, present substantial gaps arising from equipment failure and maintenance, which are ineluctable with this type of observation in harsh environments. However, prolonged (months-long) periods of multi-parametric observations during contrasted external forcing conditions are available. The raw data are reported together with flags indicating the quality status of each record. River discharge data from two hydrographic stations located near the estuary head are also provided to support data analysis and interpretation. The data set is publicly available in machine-readable format at PANGAEA (doi:10.1594/PANGAEA.845750).

  17. Multiyear high-frequency physical and environmental observations at the Guadiana Estuary

    Science.gov (United States)

    Garel, E.; Ferreira, Ó.

    2015-07-01

    High-frequency data collected continuously over a multiyear time frame are required for investigating the various agents that drive ecological and hydrodynamic processes in estuaries. Here, we present water quality and current in-situ observations from a fixed monitoring station operating from 2008 to 2014 in the lower Guadiana Estuary, southern Portugal (37°11.30' N, 7°24.67' W). The data were recorded by: a multi-parametric probe providing hourly records of temperature, chlorophyll, dissolved oxygen, turbidity, and pH at a water depth of ~ 1 m; and, a bottom-mounted acoustic Doppler current profiler measuring the pressure, near-bottom temperature, and flow velocity through the water column every 15 min. The time-series, in particular the probe one, present substantial data gaps arising from equipment failure and maintenance, which are ineluctable with this type of observations in harsh environments. However, prolonged (months-long) periods of observations during contrasted external forcing conditions are available. The raw data are reported together with quality flags indicating the status (valid/non-valid) of each record. Hourly river discharge data from two hydrographic stations located near the estuary head are also provided to support data analysis and interpretation. The dataset is publicly available at PANGAEA (doi:10.1594/PANGAEA.845750) in machine-readable format.

  18. Resolution of superior oblique myokymia with memantine.

    Science.gov (United States)

    Jain, Saurabh; Farooq, Shegufta J; Gottlob, Irene

    2008-02-01

    We describe a novel treatment of superior oblique myokymia. A 40-year-old woman was treated with gabapentin for this disorder with partial success and reported significant side effects including loss of libido and weight gain. After a drug holiday, memantine therapy was initiated resulting in a substantial improvement in her symptoms with far fewer side effects and stability on long-term maintenance therapy.

  19. Low stellar obliquities in compact multiplanet systems

    CERN Document Server

    Albrecht, Simon; Marcy, Geoffrey W; Howard, Andrew W; Isaacson, Howard; Johnson, John A

    2013-01-01

    We measure the sky-projected stellar obliquities (\\lambda) in the multiple-transiting planetary systems KOI-94 and Kepler-25, using the Rossiter-McLaughlin effect. In both cases the host stars are well-aligned with the orbital planes of the planets. For KOI-94 we find \\lambda=-11+-11 deg, confirming a recent result by Hirano and coworkers. Kepler-25 was a more challenging case because the transit depth is unusually small (0.13 %). To obtain the obliquity it was necessary to use prior knowledge of the star's projected rotation rate, and apply two different analysis methods to independent wavelength regions of the spectra. The two methods gave consistent results, \\lambda=7+-8 deg and -0.5+-5.7 deg. There are now a total of five obliquity measurements for host stars of systems of multiple transiting planets, all of which are consistent with spin-orbit alignment. This alignment is unlikely to be the result of tidal interactions, because of the relatively large orbital distances and low planetary masses in the sys...

  20. On the oscillations in Mercury's obliquity

    CERN Document Server

    Bois, E

    2007-01-01

    One major objective of MESSENGER and BepiColombo spatial missions is to accurately measure Mercury's rotation and its obliquity in order to obtain constraints on internal structure of the planet. Which is the obliquity's dynamical behavior deriving from a complete spin-orbit motion of Mercury simultaneously integrated with planetary interactions? We have used our SONYR model integrating the spin-orbit N-body problem applied to the solar System (Sun and planets). For lack of current accurate observations or ephemerides of Mercury's rotation, and therefore for lack of valid initial conditions for a numerical integration, we have built an original method for finding the libration center of the spin-orbit system and, as a consequence, for avoiding arbitrary amplitudes in librations of the spin-orbit motion as well as in Mercury's obliquity. The method has been carried out in two cases: (1) the spin-orbit motion of Mercury in the 2-body problem case (Sun-Mercury) where an uniform precession of the Keplerian orbita...

  1. Insights into streamflow generation mechanisms using high-frequency analysis of isotopes and water quality in streamflow and precipitation

    Science.gov (United States)

    von Freyberg, Jana; Kirchner, James W.

    2017-04-01

    In the pre-Alpine Alptal catchment in central Switzerland, snowmelt and rainfall events cause rapid changes not only in hydrological conditions, but also in water quality. A flood forecasting model for such a mountainous catchment thus requires process understanding that is informed by high-frequency monitoring of hydrological and hydrochemical parameters. Therefore, we installed a high-frequency sampling and analysis system near the outlet of the 0.7 km2 Erlenbach catchment, a headwater tributary of the Alp river. We measured stable water isotopes (δ18O, δ2H) in precipitation and streamwater using Picarro, Inc.'s (Santa Clara, CA, USA) newly developed Continuous Water Sampler Module (CWS) coupled to their L2130-i Cavity Ring-Down Spectrometer, at 30 min temporal resolution. Water quality was monitored with a dual-channel ion chomatograph (Metrohm AG, Herisau, Switzerland) for analysis of major cations and anions, as well as with a UV-Vis spectroscopy system and electrochemical probes (s::can Messtechnik GmbH, Vienna, Austria) for characterization of nutrients and basic water quality parameters. For quantification of trace elements and metals, we collected additional water samples for subsequent ICP-MS analysis in the laboratory. To illustrate the applicability of our newly developed automated analysis and sampling system under field conditions, we will present initial results from the 2016 fall and winter seasons at the Erlenbach catchment. During this period, river discharge was mainly fed by groundwater, as well as intermittent snowmelt and rain-on-snow events. Our high-frequency data set, along with spatially distributed sampling of snowmelt, enables a detailed analysis of source areas, flow pathways and biogeochemical processes that control chemical dynamics in streamflow and the discharge regime.

  2. High Frequency Measurements of Methane Concentrations and Carbon Isotopes at a Marsh and Landfill

    Science.gov (United States)

    Mortazavi, B.; Wilson, B.; Chanton, J.; Eller, K.; Dong, F.; Baer, D. S.; Gupta, M.; Dzwonkowski, B.

    2012-12-01

    High frequency measurements of methane concentrations and carbon isotopes can help constrain the source strengths of methane emitted to the atmosphere. We report here methane concentrations and 13C values measured at 0.5 Hz with cavity enhanced laser absorption spectrometers (Los Gatos Research) deployed at a saltmarsh in Alabama and a landfill in Florida. Methane concentrations and 13C at the saltmarsh were monitored over a 2.5 day time period at 2 m, 0.5 m above the ground as well as from the outflow of a flow-through (2 L) chamber placed on the Spartina alterniflora dominated marsh. A typical measurement cycle included regular samples from two tanks of known methane concentrations and isotopic values and from ambient air samples. Over the 2.5-day measurement period methane concentrations and isotopic ratios at 2 m averaged 1.85 ppm and -43.57‰ (±0.34, 1 SE), respectively. The concentration and isotopic values from the chamber outflow varied from 1.92 to 5.81 ppm and -38.5 to -59.3‰, respectively. Methane flux from the marsh ranged from undetectable to 3.6 mgC m-2hr-1, with high fluxes measured during low tide. The 13δCH4 of the emitted CH4 from the marsh, determined from a mass balance equation using the chamber inflow and outflow concentration and isotopic values ranged from -62.1 to -93.9‰ and averaged -77‰ (±1.25, 1SE). At the landfill ambient methane concentrations and 13C ratios measured over multiple days varied from 4.25 to 11.91 ppm and from -58.81 to -45.12‰, respectively. At higher methane concentrations the δ13C of CH4 was more depleted consistent with previously observed relationship at this site made by more traditional techniques. Over a 30-minute measurement period CH4 concentrations at the landfill could vary by as much as 15 ppm. The high frequency continuous optical measurements with field-deployed instruments provide us with an unprecedented temporal resolution of CH4 concentrations and isotopic ratios. These measurements will

  3. Diurnal and Seasonal Responses of High Frequency Chlorophyll Fluorescence and PRI Measurements to Abiotic Stress in Almonds

    Science.gov (United States)

    Bambach-Ortiz, N. E.; Paw U, K. T.

    2016-12-01

    Plants have evolved to efficiently utilize light to synthesize energy-rich carbon compounds, and at the same time, dissipate absorbed but excessive photon that would otherwise transfer excitation energy to potentially toxic reactive oxygen species (ROS). Nevertheless, even the most rapidly growing plants with the highest rates of photosynthesis only utilize about half of the light their leaves absorb during the hours of peak irradiance in sun-exposed habitats. Usually, that daily peak of irradiance coincides with high temperature and a high vapor pressure deficit, which are conditions related to plant stomata closure. Consequently, specially in water stressed environments, plants need to have mechanisms to dissipate most of absorbed photons. Plants avoid photo-oxidative damage of the photosynthetic apparatus due to the formation of ROS under excess light using different mechanisms in order to either lower the amount of ROS formation or detoxify already formed ROS. Photoinhibition is defined as a reduction in photosynthetic activity due largely to a sustained reduction in the photochemical efficiency of Photosystem II (PSII), which can be assessed by monitoring Chlorophyll a fluorescence (ChlF). Alternatively, monitoring abiotic stress effects upon photosynthetic activity and photoinhibition may be possible using high frequency spectral reflectance sensors. We aim to find the potential relationships between high frequency PRI and ChlF as indicators of photoinhibition and permanent photodamage at a seasonal scale. Preliminary results show that PRI responses are sensitive to photoinhibition, but provide a poor representation of permanent photodamage observed at a seasonal scale.

  4. High-frequency hearing thresholds: effects of age, occupational ultrasound and noise exposure.

    Science.gov (United States)

    Maccà, Isabella; Scapellato, Maria Luisa; Carrieri, Mariella; Maso, Stefano; Trevisan, Andrea; Bartolucci, Giovanni Battista

    2015-02-01

    It has been suggested that high-frequency audiometry (HFA) could represent a useful preventive measure in exposed workers. The aim was to investigate the effects of age, ultrasound and noise on high-frequency hearing thresholds. We tested 24 industrial ultrasound-exposed subjects, 113 industrial noise-exposed subjects and 148 non-exposed subjects. Each subject was tested with both conventional-frequency (0.125-8 kHz) and high-frequency (9-18 kHz) audiometry. The hearing threshold at high frequency deteriorated as a function of age, especially in subjects more than 30 years old. The ultrasound-exposed subjects had significantly higher hearing thresholds than the non-exposed ones at the high frequencies, being greatest from 10 to 14 kHz. This hearing loss was already significantly evident in subjects with exposure frequencies 4 and 6 kHz and at the high frequency of 14 kHz. After stratification for age, there was a significant difference between the two groups at 9-10 and 14-15 kHz only for those under 30 years of age. Multivariate analysis indicated that age was the primary predictor, and noise and ultrasound exposure the secondary predictors of hearing thresholds in the high-frequency range. The results suggest that HFA could be useful in the early diagnosis of noise-induced hearing loss in younger groups of workers (under 30 years of age).

  5. High-Frequency Resonant Matrix Converter using IGBT-Based Bidirectional Switches for Induction Heating

    Directory of Open Access Journals (Sweden)

    Jami Rajesh

    2014-02-01

    Full Text Available This paper deals with a novel type soft switching utility frequency AC- high frequency AC converter using asymmetrical PWM bidirectional active switches which can be defined as high frequency resonant matrix converter.This power frequency changer can directly convert utility frequency AC power to high frequency AC power ranging more than 20kHz up to 100kHz. Only one active edge resonant capacitor-assisted soft switching high frequency load resonant cyclo-converter is based on asymmetrical duty cycle PWM strategy. This high frequency cyclo-converter uses bidirectional IGBTs composed of anti-parallel one-chip reverse blocking IGBTs. This high frequency cycloconverter has some remarkable features as electrolytic capacitorless DC busline link, unity power factor correction and sinewave line current shaping, simple configuration with minimum circuit components and low cost, high efficiency and downsizing. This series load resonant cycloconverter incorporating bidirectional active power switches is developed and implemented for high efficiency consumer induction heated food cooking appliances. Its operating principle is described by using equivalent circuits. Its operating performances as soft switching operating ranges and high frequency effective power regulation characteristics are discussed on the basis of simulation and experimental results.

  6. [Diagnostic accuracy of the immersion high-frequency B-scan ultrasonography in chemical injured eyes].

    Science.gov (United States)

    Yang, Qinghua; Chen, Bing; Wang, Liqiang; Li, Zhaohui; Huang, Yifei

    2014-08-01

    To investigate the diagnostic accuracy of the immersion high-frequency B-scan ultrasonography, a noninvasive preoperative diagnosis method, in observing the anterior segment in chemical injured eyes. It was a retrospective study. Sixty-three ocular chemical injury patients (63 eyes), who accepted the keratoplasty or the artificial cornea transplant in PLA General Hospital from May 2011 to May 2013, were included in this study. All the injured eyes were examined by ultrasound bio-microscopy (UBM) and immersion high-frequency B-scan ultrasonography, respectively. The images were analyzed and the results were compared with the intraoperative findings. The observation of lens was the main parameter. All the 63 patients were examined with the UBM and the immersion high-frequency B-scan ultrasonography before the surgery. The findings of the cornea, anterior chamber angle, iris from UBM were consistent with those from the immersion high-frequency B-scan ultrasonography. As for the lens observation, in 32 eyes in which the lens were not detected by UBM, the lens were not detected in only 16 eyes, while 3 eyes with normal lens and 13 eyes with lens pacifications (1 eye with pyknotic lens) by immersion high-frequency B-scan ultrasonography. In 17 eyes in which the lens were found normal by UBM, there were only 14 eyes with normal lens and the rest 3 eyes' lens were found intumescent by immersion high-frequency B-scan ultrasonography. In 6 eyes in which lens were detected with suspicious by UBM, 2 eyes' lens were pyknotic and 4 eyes' lens were intumescent or clouded by immersion high-frequency B-scan ultrasonography. The findings of immersion high-frequency B-scan ultrasonography were highly consistent with the intraoperative findings. The lens could be observed accurately by immersion high-frequency B-scan ultrasonography in chemical injured eyes.

  7. Study on GNi-WC25 Coating by High Frequency Induction Cladding

    Institute of Scientific and Technical Information of China (English)

    张增志; 韩桂泉; 付跃文; 沈立山

    2002-01-01

    Process and mechanism of high frequency were studied in this paper by means of cold-attachment for the preparation of Gni-WC25 coating . The resu lts show its special distribution law of eddy current while the magnetic transition temperature and electric-resistivity of the coating have been measured .Wear-resistance of the high-frequency induction coating has an advantage over those of laser cladding coating and oxygen-acetylene spraying-fusing coating . Moreover , the Gni-WC25 coating by high-frequency induction claddi ng has smooth surface and even microstructure.

  8. Econometric analysis of realized covariation: high frequency based covariance, regression, and correlation in financial economics

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Shephard, N.

    2004-01-01

    This paper analyses multivariate high frequency financial data using realized covariation. We provide a new asymptotic distribution theory for standard methods such as regression, correlation analysis, and covariance. It will be based on a fixed interval of time (e.g., a day or week), allowing...... the number of high frequency returns during this period to go to infinity. Our analysis allows us to study how high frequency correlations, regressions, and covariances change through time. In particular we provide confidence intervals for each of these quantities....

  9. A novel variable polarity welding power based on high-frequency pulse modulation

    Institute of Scientific and Technical Information of China (English)

    Qiu Ling; Yang Chunli; Fan Chenglei; Lin Sanbao; Wu Yun

    2006-01-01

    A new type of variable polarity welding power modulated with high-frequency pulse current is developed.Series of high-frequency pulse current is superimposed on direct-current-electrode-negative (DCEN), which can improve the crystallization process in the weld bead as a result of the electromagnetic force generated by pulse current.Digital signal processor (DSP) is used to realize the closed-loop control of the first inverter, variable polarity output of the second inverter and high-frequency pulse current superposition.

  10. Effect of sintering process on microstructure and magnetic properties of high frequency power ferrite

    Institute of Scientific and Technical Information of China (English)

    SUN Ke; LAN Zhongwen; CHEN Shengming; SUN Yueming; YU Zhong

    2006-01-01

    An oxide ceramic process was adopted to prepare high frequency manganese-zinc (MnZn) power ferrite. In combination with the microstructure analysis of material, the influences of sintering process on initial permeability (μi) and high frequency loss in unit volume (Pcv) of MnZn power ferrite were investigated. The results show that in order to obtain fine microstructure and high frequency properties, the preferable sintering temperature and atmosphere are 1230 ℃ and oxygen partial pressure ( PO2) of 4%, respectively.

  11. Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse

    Energy Technology Data Exchange (ETDEWEB)

    Grishkov, V. E.; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2017-03-15

    Excitation of plasma waves by nonlinear currents induced by a high-frequency electromagnetic pulse is analyzed within the kinetic approach. It is shown that the most efficient source of plasma waves is the nonlinear current arising due to the gradient of the energy density of the high-frequency field. Generation of plasma waves by the drag current is usually less efficient but not negligibly small at relatively high frequencies of electron–ion collisions. The influence of electron collisions on the excitation of plasma waves by pulses of different duration is described quantitatively.

  12. Unprecedentedly strong and narrow electromagnetic emissions stimulated by high-frequency radio waves in the ionosphere.

    Science.gov (United States)

    Norin, L; Leyser, T B; Nordblad, E; Thidé, B; McCarrick, M

    2009-02-13

    Experimental results of secondary electromagnetic radiation, stimulated by high-frequency radio waves irradiating the ionosphere, are reported. We have observed emission peaks, shifted in frequency up to a few tens of Hertz from radio waves transmitted at several megahertz. These emission peaks are by far the strongest spectral features of secondary radiation that have been reported. The emissions are attributed to stimulated Brillouin scattering, long predicted but hitherto never unambiguously identified in high-frequency ionospheric interaction experiments. The experiments were performed at the High-Frequency Active Auroral Research Program (HAARP), Alaska, USA.

  13. A critical review of liquid helium temperature high frequency pulse tube cryocoolers for space applications

    Science.gov (United States)

    Wang, B.; Gan, Z. H.

    2013-08-01

    The importance of liquid helium temperature cooling technology in the aerospace field is discussed, and the results indicate that improving the efficiency of liquid helium cooling technologies, especially the liquid helium high frequency pulse tube cryocoolers, is the principal difficulty to be solved. The state of the art and recent developments of liquid helium high frequency pulse tube cryocoolers are summarized. The main scientific challenges for high frequency pulse tube cryocoolers to efficiently reach liquid helium temperatures are outlined, and the research progress addressing those challenges are reviewed. Additionally some possible solutions to the challenges are pointed out and discussed.

  14. A note for the mechanism of high-frequency oscillation instability resulted from absorbing boundary conditions

    Institute of Scientific and Technical Information of China (English)

    XIE Zhi-nan; LIAO Zhen-peng

    2008-01-01

    In this paper the explanation of the mechanism of high-frequency oscillation instability resulted from absorbing boundary conditions is further improved. And we analytically prove the proposition that for one dimensional dis- crete model of elastic wave motion, the module of reflection factor will be greater than 1 in high frequency band when artificial wave velocity is greater than 1.5 times the ratio of discrete space step to discrete time step. Based on the proof, the frequency band in which instability occurs is discussed in detail, showing such high-frequency waves are meaningless for the numerical simulation of wave motion.

  15. Exfoliated BN shell-based high-frequency magnetic core-shell materials.

    Science.gov (United States)

    Zhang, Wei; Patel, Ketan; Ren, Shenqiang

    2017-09-14

    The miniaturization of electric machines demands high frequency magnetic materials with large magnetic-flux density and low energy loss to achieve a decreased dimension of high rotational speed motors. Herein, we report a solution-processed high frequency magnetic composite (containing a nanometal FeCo core and a boron nitride (BN) shell) that simultaneously exhibits high electrical resistivity and magnetic permeability. The frequency dependent complex initial permeability and the mechanical robustness of nanocomposites are intensely dependent on the content of BN insulating phase. The results shown here suggest that insulating magnetic nanocomposites have potential for application in next-generation high-frequency electric machines with large electrical resistivity and permeability.

  16. A Novel Oblique Detonation Structure and Its Stability

    Institute of Scientific and Technical Information of China (English)

    TENG Hong-Hui; ZHAO Wei; JIANG Zong-Lin

    2007-01-01

    Oblique detonation structures induced by the wedge in the supersonic combustible gas mixtures are simulated numerically. The results show that the stationary oblique detonation structures are influenced by the gas flow Mach number, and a novel critical oblique detonation structure, which is characterized by a more complicated wave system, appears in the low Mach number cases. By introducing the inflow disturbance, its nonstationary evolution process is illustrated and its stability is verified.

  17. Stability analysis of the Martian obliquity during the Noachian era

    OpenAIRE

    2011-01-01

    Abstract We performed numerical simulations of the obliquity evolution of Mars during the Noachian era, at which time the giant planets were on drastically different orbits than today. For the preferred primordial configuration of the planets we find that there are two large zones where the Martian obliquity is stable and oscillates with an amplitude lower than 20?. These zones occur at obliquities below 30?and above 60?; intermediate values show either resonant or chaotic behaviou...

  18. High frequency wide-band transformer uses coax to achieve high turn ratio and flat response

    Science.gov (United States)

    De Parry, T.

    1966-01-01

    Center-tap push-pull transformer with toroidal core helically wound with a single coaxial cable creates a high frequency wideband transformer. This transformer has a high-turn ratio, a high coupling coefficient, and a flat broadband response.

  19. Low and High-Frequency Field Potentials of Cortical Networks Exhibit Distinct Responses to Chemicals

    Science.gov (United States)

    Neural networks grown on microelectrode arrays (MEAs) have become an important, high content in vitro assay for assessing neuronal function. MEA experiments typically examine high- frequency (HF) (>200 Hz) spikes, and bursts which can be used to discriminate between differ...

  20. High Frequency Radar Locations in the United States as of February 2016.

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset show the point locations of High Frequency (HF) radar systems across the US. HF radars measure the speed and direction of ocean surface currents in near...

  1. Effect of low-intensity extremely high frequency radiation on reproductive function in wistar rats.

    Science.gov (United States)

    Subbotina, T I; Tereshkina, O V; Khadartsev, A A; Yashin, A A

    2006-08-01

    The exposure to low-intensity extremely high frequency electromagnetic radiation during spermatogenesis was accompanied by pathological changes, which resulted in degeneration and polymorphism of spermatozoa. The number of newborn rats increased in the progeny of irradiated animals.

  2. Motion behavior of non-metallic particles under high frequency magnetic field

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhong-tao; GUO Qing-tao; YU Feng-yun; LI Jie; ZHANG Jian; LI Ting-ju

    2009-01-01

    Non-metallic particles, especially alumina, are the main inclusions in aluminum and its alloys. Numerical simulation and the corresponding experiments were carried out to study the motion behavior of alumina particles in commercial pure aluminum under high frequency magnetic field. At the meantime, multi-pipe experiment was also done to discuss the prospect of continuous elimination of non-metallic particles under high frequency magnetic field. It is shown that: 1) results of numerical simulation are in good agreement with the experimental results, which certificates the rationality of the simulation model; 2) when the intensity of high frequency magnetic field is 0.06 T, the 30 μm alumina particles in melt inner could migrate to the edge and be removed within 2 s; 3) multi-pipe elimination of alumina particles under high frequency magnetic field is also effective and has a good prospect in industrial application.

  3. Stability Analysis of an Inverted Pendulum Subjected to Combined High Frequency Harmonics and Stochastic Excitations

    Institute of Scientific and Technical Information of China (English)

    HUANG Zhi-Long; JIN Xiao-Ling; ZHU Zi-Qi

    2008-01-01

    Stability of vertical upright position of an inverted pendulum with its suspension point subjected to high frequency harmonics and stochastic excitations is investigated. Two classes of excitations, i.e., combined high frequency harmonic excitation and Gaussian white noise excitation, and high frequency bounded noise excitation, respectively,are considered. Firstly, the terms of high frequency harmonic excitations in the equation of motion of the system can be set equivalent to nonlinear stiffness terms by using the method of direct separation of motions. Then the stochastic averaging method of energy envelope is used to derive the averaged It(o) stochastic differential equation for system energy. Finally, the stability with probability 1 of the system is studied by using the largest Lyapunov exponent obtained from the averaged It(o) stochastic differential equation. The effects of system parameters on the stability of the system are discussed, and some examples are given to illustrate the efficiency of the proposed procedure.

  4. Oblique Water Wave Diffraction by a Step

    Directory of Open Access Journals (Sweden)

    Dolai P.

    2017-02-01

    Full Text Available This paper is concerned with the problem of diffraction of an obliquely incident surface water wave train on an obstacle in the form of a finite step. Havelock expansions of water wave potentials are used in the mathematical analysis to obtain the physical parameters reflection and transmission coefficients in terms of integrals. Appropriate multi-term Galerkin approximations involving ultraspherical Gegenbauer polynomials are utilized to obtain a very accurate numerical estimate for reflection and transmission coefficients which are depicted graphically. From these figures various interesting results are discussed.

  5. Oblique Water Wave Diffraction by a Step

    Science.gov (United States)

    Dolai, P.

    2017-02-01

    This paper is concerned with the problem of diffraction of an obliquely incident surface water wave train on an obstacle in the form of a finite step. Havelock expansions of water wave potentials are used in the mathematical analysis to obtain the physical parameters reflection and transmission coefficients in terms of integrals. Appropriate multi-term Galerkin approximations involving ultraspherical Gegenbauer polynomials are utilized to obtain a very accurate numerical estimate for reflection and transmission coefficients which are depicted graphically. From these figures various interesting results are discussed.

  6. A note on oblique water entry

    KAUST Repository

    Moore, M. R.

    2012-10-02

    A minor error in Howison et al. (J. Eng. Math. 48:321-337, 2004) obscured the fact that the points at which the free surface turns over in the solution of the Wagner model for the oblique impact of a two-dimensional body are directly related to the turnover points in the equivalent normal impact problem. This note corrects some of the earlier results given in Howison et al. (J. Eng. Math. 48:321-337, 2004) and discusses the implications for the applicability of the Wagner model. © 2012 Springer Science+Business Media B.V.

  7. Parkinsonian Rest Tremor Is Associated With Modulations of Subthalamic High-Frequency Oscillations.

    Science.gov (United States)

    Hirschmann, Jan; Butz, Markus; Hartmann, Christian J; Hoogenboom, Nienke; Özkurt, Tolga E; Vesper, Jan; Wojtecki, Lars; Schnitzler, Alfons

    2016-10-01

    High frequency oscillations (>200 Hz) have been observed in the basal ganglia of PD patients and were shown to be modulated by the administration of levodopa and voluntary movement. The objective of this study was to test whether the power of high-frequency oscillations in the STN is associated with spontaneous manifestation of parkinsonian rest tremor. The electromyogram of both forearms and local field potentials from the STN were recorded in 11 PD patients (10 men, age 58 [9.4] years, disease duration 9.2 [6.3] years). Patients were recorded at rest and while performing repetitive hand movements before and after levodopa intake. High-frequency oscillation power was compared across epochs containing rest tremor, tremor-free rest, or voluntary movement and related to the tremor cycle. We observed prominent slow (200-300 Hz) and fast (300-400 Hz) high-frequency oscillations. The ratio between slow and fast high-frequency oscillation power increased when tremor became manifest. This increase was consistent across nuclei (94%) and occurred in medication ON and OFF. The ratio outperformed other potential markers of tremor, such as power at individual tremor frequency, beta power, or low gamma power. For voluntary movement, we did not observe a significant difference when compared with rest or rest tremor. Finally, rhythmic modulations of high-frequency oscillation power occurred within the tremor cycle. Subthalamic high-frequency oscillation power is closely linked to the occurrence of parkinsonian rest tremor. The balance between slow and fast high-frequency oscillation power combines information on motor and medication state. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  8. A High Voltage High Frequency Resonant Inverter for Supplying DBD Devices with Short Discharge Current Pulses

    OpenAIRE

    Bonnin, Xavier; Brandelero, Julio; Videau, Nicolas; Piquet, Hubert; Meynard, Thierry

    2014-01-01

    International audience; In this paper, the merits of a high-frequency resonant converter for supplying dielectric barrier discharges (DBD) devices are established. It is shown that, thanks to its high-frequency operating condition, such a converter allows to supply DBD devices with short discharge current pulses, a high repetition rate, and to control the injected power. In addition, such a topology eliminates the matter of connecting a high-voltage transformer directly across the DBD device ...

  9. Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL

    OpenAIRE

    Mehrparvar, Amir Houshang; Mirmohammadi, Seyyed Jalil; Davari, Mohammad Hossein; MOSTAGHACI, Mehrdad; Mollasadeghi, Abolfazl; Bahaloo, Maryam; Hashemi, Seyyed Hesam

    2014-01-01

    Background: Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. Objectives: This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). Material and Methods: This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated m...

  10. High frequency system project implementation plan. [Diagnostic recording system for Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Moon, L. L.

    1976-03-12

    The High Frequency System is a new mobile, digital diagnostic recording system for use at the Nevada Test Site. Many different kinds of event data will be digitized in real-time by this system, and these data will be recorded and stored for later read-out and transmission to NADCEN. The hardware and software requirements of the High Frequency System are examined, and the parameters of the system are proposed.

  11. The Impact of Very High Frequency Surface Reverberation on Coherent Acoustic Propagation and Modeling

    Science.gov (United States)

    2015-09-30

    is to measure and model very high frequency underwater sound generated by processes at the sea surface, relevant to the high-frequency underwater...realizations generated from wave gauge data synchronized with the acoustic measurements. The curves are not generally smooth because of the limited...on Coherent Acoustic Propagation and Modeling Grant B. Deane Marine Physical Laboratory, Scripps Institution of Oceanography UCSD La Jolla, CA

  12. Design and Measurement of Planar Toroidal Transformers for Very High Frequency Power Applications

    DEFF Research Database (Denmark)

    Knott, Arnold; Pejtersen, Jens

    2012-01-01

    The quest for higher power density has led to research of very high frequency (30-300 MHz) power converters. Magnetic components based on ferrite cores have limited application within this frequency range due to increased core loss. Air-core magnetics is a viable alternative as they do not exhibi...... power converters for very high frequencies. The magnetic coupling factor of both transformers is approx. 60 % and the mutual coupling inductance is dominant up to a frequency of 50 MHz....

  13. Non-oblique Correction in Extenden Technicolor Theory

    CERN Document Server

    Kitazawa, N

    1993-01-01

    We study radiative corrections on $Zb{\\bar b}$ vertex generated by the ETC gauge bosons, ``diagonal'' as well as sideways. Although the oblique corrections due to the ETC bosons are small in comparison with the oblique correction due to the technicolor dynamics, the non-oblique corrections result in substantial shift of contour plot in the $S$-$T$ plane. We show that such a shift due to the non-oblique corrections is actually important for discussing $S$ and $T$ values in the technicolor models.

  14. Study on the dynamic characteristics of a high frequency brake based on giant magnetostrictive material

    Science.gov (United States)

    Xu, Ai Qun

    2016-06-01

    In order to meet the requirements of rapid and smooth braking, high-frequency braking using a giant magnetostrictive actuator is proposed, which can solve the problems in hydraulic braking, such as, it leaks easily, catches fire easily, is difficult to find failures, high cost on maintenance and repairing, etc. The main factors affecting the force of a high-frequency braking actuator are emphatically analyzed, the brakes dynamic model is established and a performance testing device for high frequency braking is constructed based on LabVIEW. The output force of the actuator increases with the excitation current of the driving coil increasing, and the increased multiple of the output force is greater than that of the excitation current; the range of the actuator force amplitude is 121.63 N ∼ 158.14 N, which changes little, while excitation frequency changes between 200 Hz ∼ 1000 Hz. In a minor range of pre-stress, the output force decreases with an increase in the axial pre-stress of the giant magnetostrictive rod, but is not obvious. It is known by finite element simulation analysis that high-frequency braking shortens the braking displacement and time effectively, which proves the feasibility and effectiveness of high frequency braking. Theoretical analysis and experimental results indicate that the output force of the actuator changes at the same frequency with excitation current; it is controllable and its mechanical properties meet the requirements of high frequency braking.

  15. High-Frequency Transcranial Random Noise Stimulation Enhances Perception of Facial Identity.

    Science.gov (United States)

    Romanska, Aleksandra; Rezlescu, Constantin; Susilo, Tirta; Duchaine, Bradley; Banissy, Michael J

    2015-11-01

    Recently, a number of studies have demonstrated the utility of transcranial current stimulation as a tool to facilitate a variety of cognitive and perceptual abilities. Few studies, though, have examined the utility of this approach for the processing of social information. Here, we conducted 2 experiments to explore whether a single session of high-frequency transcranial random noise stimulation (tRNS) targeted at lateral occipitotemporal cortices would enhance facial identity perception. In Experiment 1, participants received 20 min of active high-frequency tRNS or sham stimulation prior to completing the tasks examining facial identity perception or trustworthiness perception. Active high-frequency tRNS facilitated facial identity perception, but not trustworthiness perception. Experiment 2 assessed the spatial specificity of this effect by delivering 20 min of active high-frequency tRNS to lateral occipitotemporal cortices or sensorimotor cortices prior to participants completing the same facial identity perception task used in Experiment 1. High-frequency tRNS targeted at lateral occipitotemporal cortices enhanced performance relative to motor cortex stimulation. These findings show that high-frequency tRNS to lateral occipitotemporal cortices produces task-specific and site-specific enhancements in face perception.

  16. Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy

    Science.gov (United States)

    Papadelis, Christos; Tamilia, Eleonora; Stufflebeam, Steven; Grant, Patricia E.; Madsen, Joseph R.; Pearl, Phillip L.; Tanaka, Naoaki

    2016-01-01

    Crucial to the success of epilepsy surgery is the availability of a robust biomarker that identifies the Epileptogenic Zone (EZ). High Frequency Oscillations (HFOs) have emerged as potential presurgical biomarkers for the identification of the EZ in addition to Interictal Epileptiform Discharges (IEDs) and ictal activity. Although they are promising to localize the EZ, they are not yet suited for the diagnosis or monitoring of epilepsy in clinical practice. Primary barriers remain: the lack of a formal and global definition for HFOs; the consequent heterogeneity of methodological approaches used for their study; and the practical difficulties to detect and localize them noninvasively from scalp recordings. Here, we present a methodology for the recording, detection, and localization of interictal HFOs from pediatric patients with refractory epilepsy. We report representative data of HFOs detected noninvasively from interictal scalp EEG and MEG from two children undergoing surgery. The underlying generators of HFOs were localized by solving the inverse problem and their localization was compared to the Seizure Onset Zone (SOZ) as this was defined by the epileptologists. For both patients, Interictal Epileptogenic Discharges (IEDs) and HFOs were localized with source imaging at concordant locations. For one patient, intracranial EEG (iEEG) data were also available. For this patient, we found that the HFOs localization was concordant between noninvasive and invasive methods. The comparison of iEEG with the results from scalp recordings served to validate these findings. To our best knowledge, this is the first study that presents the source localization of scalp HFOs from simultaneous EEG and MEG recordings comparing the results with invasive recordings. These findings suggest that HFOs can be reliably detected and localized noninvasively with scalp EEG and MEG. We conclude that the noninvasive localization of interictal HFOs could significantly improve the

  17. Detection of High Frequency Oscillations by Hybrid Depth Electrodes in Standard Clinical Intracranial EEG Recordings

    Directory of Open Access Journals (Sweden)

    Efstathios D Kondylis

    2014-08-01

    Full Text Available High frequency oscillations (HFOs have been proposed as a novel marker for epileptogenic tissue, spurring tremendous research interest into the characterization of these transient events. A wealth of continuously recorded intracranial electroencephalographic (iEEG data is currently available from patients undergoing invasive monitoring for the surgical treatment of epilepsy. In contrast to data recorded on research-customized recording systems, data from clinical acquisition systems remain an underutilized resource for HFO detection in most centers. The effective and reliable use of this clinically obtained data would be an important advance in the ongoing study of HFOs and their relationship to ictogenesis. The diagnostic utility of HFOs ultimately will be limited by the ability of clinicians to detect these brief, sporadic, and low amplitude events in an electrically noisy clinical environment. Indeed, one of the most significant factors limiting the use of such clinical recordings for research purposes is their low signal to noise ratio, especially in the higher frequency bands. In order to investigate the presence of HFOs in clinical data, we first obtained continuous intracranial recordings in a typical clinical environment using a commercially available, commonly utilized data acquisition system and off the shelf hybrid macro/micro depth electrodes. This data was then inspected for the presence of HFOs using semi-automated methods and expert manual review. With targeted removal of noise frequency content, HFOs were detected on both macro- and micro-contacts, and preferentially localized to seizure onset zones. HFOs detected by the offline, semi-automated method were also validated in the clinical viewer, demonstrating that 1 this clinical system allows for the visualization of HFOs, and 2 with effective signal processing, clinical recordings can yield valuable information for offline analysis.

  18. High-frequency audiometry reveals high prevalence of aminoglycoside ototoxicity in children with cystic fibrosis.

    Science.gov (United States)

    Al-Malky, Ghada; Dawson, Sally J; Sirimanna, Tony; Bagkeris, Emmanouil; Suri, Ranjan

    2015-03-01

    Intravenous aminoglycoside (IV AG) antibiotics, widely used in patients with cystic fibrosis (CF), are known to have ototoxic complications. Despite this, audiological monitoring is not commonly performed and if performed, uses only standard pure-tone audiometry (PTA). The aim of this study was to investigate ototoxicity in CF children, to determine the most appropriate audiological tests and to identify possible risk factors. Auditory assessment was performed in CF children using standard pure tone audiometry (PTA), extended high-frequency (EHF) audiometry and distortion-product otoacoustic emissions (DPOAE). 70 CF children, mean (SD) age 10.7 (3.5) years, were recruited. Of the 63 children who received IV AG, 15 (24%) children had ototoxicity detected by EHF audiometry and DPOAE. Standard PTA only detected ototoxicity in 13 children. Eleven of these children had received at least 10 courses of IV AG courses. A 25 to 85 dBHL hearing loss (mean±SD: 57.5±25.7 dBHL) across all EHF frequencies and a significant drop in DPOAE amplitudes at frequencies 4 to 8 kHz were detected. However, standard PTA detected a significant hearing loss (>20 dBHL) only at 8 kHz in 5 of these 15 children and none in 2 subjects who had significantly elevated EHF thresholds. The number of courses of IV AG received, age and lower lung function were shown to be risk factors for ototoxicity. CF children who had received at least 10 courses of IV AG had a higher risk of ototoxicity. EHF audiometry identified 2 more children with ototoxicity than standard PTA and depending on facilities available, should be the test of choice for detecting ototoxicity in children with CF receiving IV AG. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  19. A high-frequency kriging approach for non-stationary environmental processes

    Energy Technology Data Exchange (ETDEWEB)

    Fuentes, M. [North Carolina State Univ., Raleigh, NC (United States). Dept. of Statistics

    2001-07-01

    Emission reductions were mandated in the Clean Air Act Amendments of 1990 with the expectation that they would result in major reductions in the concentrations of atmospherically transported pollutants. The emission reductions are intended to reduce public health risks and to protect sensitive ecosystems. To determine whether the emission reductions are having the intended effect on atmospheric concentrations, monitoring data must be analyzed taking into consideration the spatial structure shown by the data. Maps of pollutant concentrations and fluxes are useful over different geopolitical boundaries, to discover when, where, and to what extent the U.S. Nation's air quality is improving or declining. Since the spatial covariance structure shown by the data changes with location, the standard kriging methodology for spatial interpolation cannot be used because it assumes stationarity of the process. We present a new methodology for spatial interpolation of non-stationary processes. In this method the field is represented locally as a stationary isotropic random field, but the parameters of the stationary random field are allowed to vary across space. A procedure for interpolation is presented that uses an expression for the spectral density at high frequencies. New fitting algorithms are developed using spectral approaches. In cases where the data are distributed exactly or approximately on a lattice, it is argued that spectral approaches have potentially enormous computational benefits compared with maximum likelihood. The methods are extended to interpolation questions using approximate Bayesian approaches to account for parameter uncertainty. We develop applications to obtain the total loading of pollutant concentrations and fluxes over different geo-political boundaries. (author)

  20. Continuous-flow sorting of microalgae cells based on lipid content by high frequency dielectrophoresis

    Directory of Open Access Journals (Sweden)

    Doug Redelman

    2016-08-01

    Full Text Available This paper presents a continuous-flow cell screening device to isolate and separate microalgae cells (Chlamydomonas reinhardtii based on lipid content using high frequency (50 MHz dielectrophoresis. This device enables screening of microalgae due to the balance between lateral DEP forces relative to hydrodynamic forces. Positive DEP force along with amplitude-modulated electric field exerted on the cells flowing over the planar interdigitated electrodes, manipulated low-lipid cell trajectories in a zigzag pattern. Theoretical modelling confirmed cell trajectories during sorting. Separation quantification and sensitivity analysis were conducted with time-course experiments and collected samples were analysed by flow cytometry. Experimental testing with nitrogen starveddw15-1 (high-lipid, HL and pgd1 mutant (low-lipid, LL strains were carried out at different time periods, and clear separation of the two populations was achieved. Experimental results demonstrated that three populations were produced during nitrogen starvation: HL, LL and low-chlorophyll (LC populations. Presence of the LC population can affect the binary separation performance. The continuous-flow micro-separator can separate 74% of the HL and 75% of the LL out of the starting sample using a 50 MHz, 30 voltages peak-to-peak AC electric field at Day 6 of the nitrogen starvation. The separation occurred between LL (low-lipid: 86.1% at Outlet # 1 and LC (88.8% at Outlet # 2 at Day 9 of the nitrogen starvation. This device can be used for onsite monitoring; therefore, it has the potential to reduce biofuel production costs

  1. Perception and coding of high-frequency spectral notches: potential implications for sound localization.

    Science.gov (United States)

    Alves-Pinto, Ana; Palmer, Alan R; Lopez-Poveda, Enrique A

    2014-01-01

    The interaction of sound waves with the human pinna introduces high-frequency notches (5-10 kHz) in the stimulus spectrum that are thought to be useful for vertical sound localization. A common view is that these notches are encoded as rate profiles in the auditory nerve (AN). Here, we review previously published psychoacoustical evidence in humans and computer-model simulations of inner hair cell responses to noises with and without high-frequency spectral notches that dispute this view. We also present new recordings from guinea pig AN and "ideal observer" analyses of these recordings that suggest that discrimination between noises with and without high-frequency spectral notches is probably based on the information carried in the temporal pattern of AN discharges. The exact nature of the neural code involved remains nevertheless uncertain: computer model simulations suggest that high-frequency spectral notches are encoded in spike timing patterns that may be operant in the 4-7 kHz frequency regime, while "ideal observer" analysis of experimental neural responses suggest that an effective cue for high-frequency spectral discrimination may be based on sampling rates of spike arrivals of AN fibers using non-overlapping time binwidths of between 4 and 9 ms. Neural responses show that sensitivity to high-frequency notches is greatest for fibers with low and medium spontaneous rates than for fibers with high spontaneous rates. Based on this evidence, we conjecture that inter-subject variability at high-frequency spectral notch detection and, consequently, at vertical sound localization may partly reflect individual differences in the available number of functional medium- and low-spontaneous-rate fibers.

  2. Perception and coding of high-frequency spectral notches: Potential implications for sound localization

    Directory of Open Access Journals (Sweden)

    Ana eAlves-Pinto

    2014-05-01

    Full Text Available The interaction of sound waves with the human pinna introduces high-frequency notches (5-10 kHz in the stimulus spectrum that are thought to be useful for vertical sound localization. A common view is that these notches are encoded as rate profiles in the auditory nerve (AN. Here, we review previously published psychoacoustical evidence in humans and computer-model simulations of inner hair cell responses to noises with and without high-frequency spectral notches that dispute this view. We also present new recordings from guinea pig AN and ‘ideal observer’ analyses of these recordings that suggest that discrimination between noises with and without high-frequency spectral notches is probably based on the information carried in the temporal pattern of AN discharges. The exact nature of the neural code involved remains nevertheless uncertain: computer model simulations suggest that high-frequency spectral notches are encoded in spike timing patterns that may be operant in the 4-7 kHz frequency regime, while ‘ideal observer’ analysis of experimental neural responses suggest that an effective cue for high-frequency spectral discrimination may be based on sampling rates of spike arrivals of AN fibers using non-overlapping time binwidths of between 4 and 9 ms. Neural responses show that sensitivity to high-frequency notches is greatest for fibers with low and medium spontaneous rates than for fibers with high spontaneous rates. Based on this evidence, we conjecture that inter-subject variability at high-frequency spectral notch detection and, consequently, at vertical sound localization may partly reflect individual differences in the available number of functional medium- and low-spontaneous-rate fibers.

  3. Parameteric studies of nonlinear oblique magnetosonic waves in two-ion-species plasmas

    Science.gov (United States)

    Toida, Mieko; Kondo, Yuichi

    2011-06-01

    The study of the effects of ion composition on perpendicular magnetosonic waves in two-ion-species plasmas [M. Toida, H. Higashino, and Y. Ohsawa, J. Phys. Soc. Jpn. 76, 104052 (2007)] is extended to include oblique waves. First, the conditions necessary for KdV equations for low- and high-frequency modes to be valid are analytically obtained. The upper limit of the amplitude of the low-frequency-mode pulse is expressed as a function of the propagation angle θ, density ratio, and cyclotron frequency ratio of the two ion species. Next, with electromagnetic particle simulations, the nonlinear evolution of a long-wavelength low-frequency-mode disturbance is examined for various θs in two plasmas with different ion densities and cyclotron frequency ratios, and the theory for the low-frequency-mode pulse is confirmed. It is also shown that if the pulse amplitude exceeds the theoretical value of the upper limit of the amplitude, then shorter-wavelength low- and high-frequency-mode waves are generated.

  4. Reduced Oblique Effect in Children with Autism Spectrum Disorders (ASD)

    Science.gov (United States)

    Sysoeva, Olga V.; Davletshina, Maria A.; Orekhova, Elena V.; Galuta, Ilia A.; Stroganova, Tatiana A.

    2016-01-01

    People are very precise in the discrimination of a line orientation relative to the cardinal (vertical and horizontal) axes, while their orientation discrimination sensitivity along the oblique axes is less refined. This difference in discrimination sensitivity along cardinal and oblique axes is called the “oblique effect.” Given that the oblique effect is a basic feature of visual processing with an early developmental origin, its investigation in children with Autism Spectrum Disorder (ASD) may shed light on the nature of visual sensory abnormalities frequently reported in this population. We examined line orientation sensitivity along oblique and vertical axes in a sample of 26 boys with ASD (IQ > 68) and 38 typically developing (TD) boys aged 7–15 years, as well as in a subsample of carefully IQ-matched ASD and TD participants. Children were asked to detect the direction of tilt of a high-contrast black-and-white grating relative to vertical (90°) or oblique (45°) templates. The oblique effect was reduced in children with ASD as compared to TD participants, irrespective of their IQ. This reduction was due to poor orientation sensitivity along the vertical axis in ASD children, while their ability to discriminate line orientation along the oblique axis was unaffected. We speculate that this deficit in sensitivity to vertical orientation may reflect disrupted mechanisms of early experience-dependent learning that takes place during the critical period for orientation selectivity. PMID:26834540

  5. Interface Defeat of Long Rods Impacting Oblique Silicon Carbide

    Science.gov (United States)

    2011-02-01

    Test data for gold rods impacting unconfined silicon carbide targets are reported. This work focuses on the dwell phenomenon exhibited by silicon ... carbide for targets at obliquity. Experiments are presented for obliquities of 30 deg, 45 deg and 60 deg, with and without cover plates. Results are compared to normal impact.

  6. 33 CFR 118.90 - Bridges crossing channel obliquely.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Bridges crossing channel obliquely. 118.90 Section 118.90 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.90 Bridges crossing channel obliquely....

  7. High-frequency oscillations in Parkinson's disease: spatial distribution and clinical relevance.

    Science.gov (United States)

    Wang, Jing; Hirschmann, Jan; Elben, Saskia; Hartmann, Christian J; Vesper, Jan; Wojtecki, Lars; Schnitzler, Alfons

    2014-09-01

    The pathophysiology of Parkinson's disease (PD) has been related to excessive beta band oscillations in the basal ganglia. Recent recordings from the subthalamic nucleus of PD patients showed that beta oscillations show strong cross-frequency coupling with high-frequency oscillations (>200 Hz). However, little is known about the characteristics and functional properties of these oscillations. We studied the spatial distribution of high-frequency oscillations and their relation to PD motor symptoms. We included 10 PD patients in medication OFF who underwent implantation of deep brain stimulation (DBS) electrodes. Intraoperative five-channel microelectrode recordings were performed at 9 to 10 recording sites within the subthalamic nucleus and its immediate surroundings. We found a focal spatial distribution of high-frequency oscillations with highest power 2 mm below the dorsolateral border of the subthalamic nucleus. Within the subthalamic nucleus, power peaked slightly anterior to the DBS target site. In addition, contralateral akinesia/rigidity scores were negatively correlated with high-frequency oscillation power. Our results demonstrate a focal origin of high-frequency oscillations within the subthalamic nucleus and provide further evidence for their functional association with motor state. © 2014 International Parkinson and Movement Disorder Society.

  8. The high frequency characteristics of laser reflection and visible light during solid state disk laser welding

    Science.gov (United States)

    Gao, Xiangdong; You, Deyong; Katayama, Seiji

    2015-07-01

    Optical properties are related to weld quality during laser welding. Visible light radiation generated from optical-induced plasma and laser reflection is considered a key element reflecting weld quality. An in-depth analysis of the high-frequency component of optical signals is conducted. A combination of a photoelectric sensor and an optical filter helped to obtain visible light reflection and laser reflection in the welding process. Two groups of optical signals were sampled at a high sampling rate (250 kHz) using an oscilloscope. Frequencies in the ranges 1-10 kHz and 10-125 kHz were investigated respectively. Experimental results showed that there was an obvious correlation between the high-frequency signal and the laser power, while the high-frequency signal was not sensitive to changes in welding speed. In particular, when the defocus position was changed, only a high frequency of the visible light signal was observed, while the high frequency of the laser reflection signal remained unchanged. The basic correlation between optical features and welding status during the laser welding process is specified, which helps to provide a new research focus for investigating the stability of welding status.

  9. High-frequency profile in adolescents and its relationship with the use of personal stereo devices

    Directory of Open Access Journals (Sweden)

    Renata Almeida Araújo Silvestre

    2016-04-01

    Full Text Available Abstract Objective: To analyze and correlate the audiometric findings of high frequencies (9–16 kHz in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. Method: This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc. and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Results: Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. Conclusion: The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population.

  10. High-frequency gamblers show increased resistance to extinction following partial reinforcement.

    Science.gov (United States)

    Horsley, Rachel R; Osborne, Matthew; Norman, Christine; Wells, Timothy

    2012-04-15

    Behaviours that have been rewarded intermittently persist for longer during periods of non-reward than behaviours that have been rewarded continuously. This classic phenomenon is known as the partial reinforcement extinction effect. For decades it has been generally understood that this phenomenon is fundamental to the persistence of gambling in the absence of winning. One obvious, yet untested hypothesis arising from this is that persistent (here, high-frequency) gamblers might be more sensitive to partial reinforcement contingencies. Therefore, our aim was to test the hypothesis that compared to low-frequency gamblers, high-frequency gamblers would show greater resistance to extinction following partial reinforcement in a computer based experiment. Participants were 19 high-frequency gamblers and 21 low-frequency gamblers, all healthy non-smokers aged between 18 and 52. Following partial or continuous reinforcement, persistence of responding in extinction was measured as the number of times a target response was made. After partial reinforcement, high-frequency gamblers made the target response a greater number of times in extinction (compared to low-frequency gamblers). Moreover, the partial reinforcement extinction effect was larger in high-frequency gamblers than in low-frequency gamblers. It remains to be seen whether increased sensitivity to partial reinforcement is a cause or effect of persistent gambling. Nevertheless, the present study represents an important first step in investigating the role of simple partial reinforcement contingencies in determining resistance to extinction in gamblers, the importance of which, whilst hitherto recognised, has never been demonstrated experimentally.

  11. Adaptive high-frequency information fusion algorithm of radar and optical images

    Science.gov (United States)

    Wang, Yiding; Qin, Shuai

    2011-12-01

    An adaptive High-frequency Information Fusion Algorithm of Radar and Optical Images is proposed in this paper, in order to improve the resolution of the radar image and reserve more radar information. Firstly, Hough Transform is adopted in the process of low-resolution radar image and high-resolution optical image registration. The implicit linear information is extracted from two different heterogeneous images for better result. Then NSCT transform is used for decomposition and fusion. In different decomposition layers or in the same layer with different directions, fusion rules are adaptive for the high-frequency information of images. The ratio values of high frequency information entropy, variance, gradient and edge strength are calculated after NSCT decomposition. High frequency information entropy, variance, gradient or edge strength, which has the smallest ratio value, is selected as an optimal rule for regional fusion. High-frequency information of radar image could be better retained, at the same time the low-frequency information of optical image also could be remained. Experimental results showed that our approach performs better than those methods with single fusion rule.

  12. High Frequency Tan Delta Measurement Method for 132kV Transmission Underground Cables

    Directory of Open Access Journals (Sweden)

    A.R. Avinash

    2015-07-01

    Full Text Available Tangent Delta is a measurement technique to investigate cables insulation strength. Current techniques utilize Very Low Frequency (VLF at 0.1 Hz and power frequency at 50 Hz. However, high voltages are required, thus requiring larger space and cost. Proposed method of tangent delta testing utilizes High frequency Low voltage diagnoses. The phase between the current and the voltage is utilized to determine the tangent delta (tan δ. The aim of this study is to develop a low voltage high frequency tangent delta measurement method and test if it can discriminate manufactured 132 kV good conditioned cable sample from defect induced cables with void, scotched and contamination in its insulation. Impurities are clearly discriminated using this method. Comparison of Tangent Delta of cables manufactured simultaneously in good condition and defect induced is performed using High Frequency Tangent Delta method and in 50 Hz conventional method to validate the effectiveness of the measurement technique. The High Frequency AC setup utilizes a small testing environment which can sample small lengths with minimum 1 m length of cable. The small lengths will result in the reduction of total capacitance of the cable but using High Frequency induces high electric stress on XLPE layer thus resulting in measureable dielectric current.

  13. Bow and Oblique Shock Formation in Soap Film

    Science.gov (United States)

    Kim, Ildoo; Mandre, Shreyas; Sane, Aakash

    2015-11-01

    In recent years, soap films have been exploited primarily to approximate two-dimensional flows while their three-dimensional character is relatively unattended. An example of the three-dimensional character of the flow in a soap film is the observed Marangoni shock wave when the flow speed exceeds the wave speed. In this study, we investigated the formation of bow and oblique shocks in soap films generated by wedges with different deflection angles. When the wedge deflection angle is small and the film flows fast, oblique shocks are observed. When the oblique shock cannot exists, bow shock is formed upstream the wedge. We characterized the oblique shock angle as a function of the wedge deflection angle and the flow speed, and we also present the criteria for transition between bow and oblique Marangoni shocks in soap films.

  14. Obliquity Variability of a Potentially Habitable Early Venus

    CERN Document Server

    Barnes, Jason W; Lissauer, Jack J; Chambers, John; Hedman, Matthew M

    2016-01-01

    Venus currently rotates slowly, with its spin controlled by solid-body and atmospheric thermal tides. However, conditions may have been far different 4 billion years ago, when the Sun was fainter and most of the carbon within Venus could have been in solid form, implying a low-mass atmosphere. We investigate how the obliquity would have varied for a hypothetical rapidly rotating Early Venus. The obliquity variation structure of an ensemble of hypothetical Early Venuses is simpler than that Earth would have if it lacked its large Moon (Lissauer et al., 2012), having just one primary chaotic regime at high prograde obliquities. We note an unexpected long-term variability of up to $\\pm7^\\circ$ for retrograde Venuses. Low-obliquity Venuses show very low total obliquity variability over billion-year timescales -- comparable to that of the real Moon-influenced Earth.

  15. First dynamic model of dissolved organic carbon derived directly from high-frequency observations through contiguous storms.

    Science.gov (United States)

    Jones, Timothy D; Chappell, Nick A; Tych, Wlodek

    2014-11-18

    The first dynamic model of dissolved organic carbon (DOC) export in streams derived directly from high frequency (subhourly) observations sampled at a regular interval through contiguous storms is presented. The optimal model, identified using the recently developed RIVC algorithm, captured the rapid dynamics of DOC load from 15 min monitored rainfall with high simulation efficiencies and constrained uncertainty with a second-order (two-pathway) structure. Most of the DOC export in the four headwater basins studied was associated with the faster hydrometric pathway (also modeled in parallel), and was soon exhausted in the slower pathway. A delay in the DOC mobilization became apparent as the ambient temperatures increased. These features of the component pathways were quantified in the dynamic response characteristics (DRCs) identified by RIVC. The model and associated DRCs are intended as a foundation for a better understanding of storm-related DOC dynamics and predictability, given the increasing availability of subhourly DOC concentration data.

  16. Aerodynamic noise characterization of a full-scale wind turbine through high-frequency surface pressure measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Bak, Christian;

    2015-01-01

    The aim of this work is to investigate and characterize the high-frequency surface pressure fluctuations on a full-scale wind turbine blade and in particular the influence of the atmospheric turbulence. As these fluctuations are highly correlated to the sources of both turbulent inflow noise...... wind turbine with a 80 m diameter rotor as well as measurements of an airfoil section tested in a wind tunnel. The turbine was extensively equipped in order to monitor the local inflow onto the rotating blades. Further a section of the 38 m long blade was instrumented with 50 microphones flush......-mounted relative to the blade surface. The measurements of surface pressure spectra are compared with the results of two engineering models for trailing edge noise and for turbulent inflow noise. The measured pressure fluctuations are related to the local inflow angle and are also compared to measurements...

  17. The Role of Rift Obliquity During Pangea Fragmentation

    Science.gov (United States)

    Brune, S.; Butterworth, N. P.; Williams, S.; Müller, D.

    2014-12-01

    Does supercontinent break-up follow specific laws? What parameters control the success and the failure of rift systems? Recent analytical and geodynamic modeling suggests that oblique rifting is energetically preferred over orthogonal rifting. This implies that during rift competition, highly oblique branches proceed to break-up while less oblique ones become inactive. These models predict that the relative motion of Earth's continents during supercontinent break-up is affected by the orientation and shape of individual rift systems. Here, we test this hypothesis based on latest plate tectonic reconstructions. Using PyGPlates, a recently developed Python library that allows script-based access to the plate reconstruction software GPlates, we quantify rift obliquity, extension velocity and their temporal evolution for continent-scale rift systems of the past 200 Myr. Indeed we find that many rift systems contributing to Pangea fragmentation involved strong rift obliquity. East and West Gondwana for instance split along the East African coast with a mean obliquity of 55° (measured as the angle between local rift trend normal and extension direction). While formation of the central and southern South Atlantic segment involved a low obliquity of 10°, the Equatorial Atlantic opened under a high angle of 60°. Rifting between Australia and Antarctica involved two stages with 25° prior to 100 Ma followed by 50° obliquity and distinct increase of extension velocity. Analyzing the entire passive margin system that formed during Pangea breakup, we find a mean obliquity of 40°, with a standard deviation of 20°. Hence 50% of these margins formed with an angle of 40° or more. Considering that many conceptual models of rifting and passive margin formation assume 2D deformation, our study quantifies the degree to which such 2D models are globally applicable, and highlights the importance of 3D models where oblique rifting is the dominant mode of deformation.

  18. Wafer scale oblique angle plasma etching

    Energy Technology Data Exchange (ETDEWEB)

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  19. MIX and Instability Growth from Oblique Shock

    Energy Technology Data Exchange (ETDEWEB)

    Molitoris, J D; Batteux, J D; Garza, R G; Tringe, J W; Souers, P C; Forbes, J W

    2011-07-22

    We have studied the formation and evolution of shock-induced mix resulting from interface features in a divergent cylindrical geometry. In this research a cylindrical core of high-explosive was detonated to create an oblique shock wave and accelerate the interface. The interfaces studied were between the high-explosive/aluminum, aluminum/plastic, and finally plastic/air. Pre-emplaced surface features added to the aluminum were used to modify this interface. Time sequence radiographic imaging quantified the resulting instability formation from the growth phase to over 60 {micro}s post-detonation. Thus allowing the study of the onset of mix and evolution to turbulence. The plastic used here was porous polyethylene. Radiographic image data are compared with numerical simulations of the experiments.

  20. Partial Oblique Projection Learning for Optimal Generalization

    Institute of Scientific and Technical Information of China (English)

    LIU Benyong; ZHANG Jing

    2004-01-01

    In practice,it is necessary to implement an incremental and active learning for a learning method.In terms of such implementation,this paper shows that the previously discussed S-L projection learning is inappropriate to constructing a family of projection learning,and proposes a new version called partial oblique projection (POP) learning.In POP learning,a function space is decomposed into two complementary subspaces,so that functions belonging to one of the subspaces can be completely estimated in noiseless case;while in noisy case,the dispersions are set to be the smallest.In addition,a general form of POP learning is presented and the results of a simulation are given.

  1. High Frequency Resonance Damping of DFIG based Wind Power System under Weak Network

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    When operating in a micro or weak grid which has a relatively large network impedance, the Doubly Fed Induction Generator (DFIG) based wind power generation system is prone to suffer high frequency resonance due to the impedance interaction between DFIG system and the parallel compensated network...... (series RL + shunt C). In order to improve the performance of the DFIG system as well as other units and loads connected to the weak grid, the high frequency resonance needs to be effectively damped. In this paper, the proposed active damping control strategy is able to implement effective damping either...... in the Rotor Side Converter (RSC) or in the Grid Side Converter (GSC), through the introduction of virtual positive capacitor or virtual negative inductor to reshape the DFIG system impedance and mitigate the high frequency resonance. A detailed theoretical explanation on the virtual positive capacitor...

  2. A Method for Gray-Scale Imaging of Blood Flow Using High-Frequency Ultrasound.

    Science.gov (United States)

    Yang, Jun; Pang, Chao; Song, Xue-Dong; Gao, Xuan

    2017-07-01

    This paper presents a new method that complements current techniques available in the high-frequency blood imaging field. A comprehensive scattering model was established to determine the feasibility and frequency range of the blood flow imaging of superficial organs and tissues using high-frequency ultrasound. The transmitting and receiving modes and an algorithm were designed to obtain blood flow information based on differentiation between tissues and blood flow. The system was created and tested first with a model that simulates blood flow and was then used on human tissue. A fine-scale image of a blood vessel could be obtained with this system. Moreover, this method can obtain weak blood flow signal using single pulse rather than the traditional pulse-code method and maintains a high resolution that can be matched to high-frequency structural imaging. This study provides a reliable method for further applications related to diagnoses of superficial organs.

  3. Extended high-frequency audiometry (9,000-20,000 Hz). Usefulness in audiological diagnosis.

    Science.gov (United States)

    Rodríguez Valiente, Antonio; Roldán Fidalgo, Amaya; Villarreal, Ithzel M; García Berrocal, José R

    2016-01-01

    Early detection and appropriate treatment of hearing loss are essential to minimise the consequences of hearing loss. In addition to conventional audiometry (125-8,000 Hz), extended high-frequency audiometry (9,000-20,000 Hz) is available. This type of audiometry may be useful in early diagnosis of hearing loss in certain conditions, such as the ototoxic effect of cisplatin-based treatment, noise exposure or oral misunderstanding, especially in noisy environments. Eleven examples are shown in which extended high-frequency audiometry has been useful in early detection of hearing loss, despite the subject having a normal conventional audiometry. The goal of the present paper was to highlight the importance of the extended high-frequency audiometry examination for it to become a standard tool in routine audiological examinations.

  4. Dynamic properties of ionospheric plasma turbulence driven by high-power high-frequency radiowaves

    Science.gov (United States)

    Grach, S. M.; Sergeev, E. N.; Mishin, E. V.; Shindin, A. V.

    2017-02-01

    A review is given of the current state-of-the-art of experimental studies and the theoretical understanding of nonlinear phenomena that occur in the ionospheric F-layer irradiated by high-power high-frequency ground-based transmitters. The main focus is on the dynamic features of high-frequency turbulence (plasma waves) and low-frequency turbulence (density irregularities of various scales) that have been studied in experiments at the Sura and HAARP heating facilities operated in temporal and frequency regimes specially designed with consideration of the characteristic properties of nonlinear processes in the perturbed ionosphere using modern radio receivers and optical instruments. Experimental results are compared with theoretical turbulence models for a magnetized collisional plasma in a high-frequency electromagnetic field, allowing the identification of the processes responsible for the observed features of artificial ionospheric turbulence.

  5. Influence of high frequency pulse on electrode wear in micro-EDM

    Directory of Open Access Journals (Sweden)

    Xiao-peng Li

    2014-09-01

    Full Text Available An electromagnetic coupling mathematical model is established by finite element method and is verified by the contrastive experiments of copper matrix Ni–TiN cylindrical coating electrode, copper electrode and Cu50W electrode. The wear mechanism of Ni–TiN/Cu composite electrode in the case of high-frequency pulse current is studied, and the influence of the fluctuation frequency of discharge current on electrode wear in micro-EDM is found out. Compared with the electrode made from homogeneous material, the high frequency electromagnetic properties of Ni–TiN composite layer can be used effectively to inhibit the effect of high frequency pulse on the electrode and improve the distribution trend of current density.

  6. Influence of high frequency pulse on electrode wear in micro-EDM

    Institute of Scientific and Technical Information of China (English)

    Xiao-peng LI; Yuan-gang WANG; Fu-ling ZHAO; Meng-hua WU; Yu LIU

    2014-01-01

    An electromagnetic coupling mathematical model is established by finite element method and is verified by the contrastive experiments of copper matrix NieTiN cylindrical coating electrode, copper electrode and Cu50W electrode. The wear mechanism of NieTiN/Cu composite electrode in the case of high-frequency pulse current is studied, and the influence of the fluctuation frequency of discharge current on electrode wear in micro-EDM is found out. Compared with the electrode made from homogeneous material, the high frequency electromagnetic properties of NieTiN composite layer can be used effectively to inhibit the effect of high frequency pulse on the electrode and improve the distribution trend of current density.

  7. High Frequency Resonance Damping of DFIG based Wind Power System under Weak Network

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    When operating in a micro or weak grid which has a relatively large network impedance, the Doubly Fed Induction Generator (DFIG) based wind power generation system is prone to suffer high frequency resonance due to the impedance interaction between DFIG system and the parallel compensated network...... (series RL + shunt C). In order to improve the performance of the DFIG system as well as other units and loads connected to the weak grid, the high frequency resonance needs to be effectively damped. In this paper, the proposed active damping control strategy is able to implement effective damping either...... in the Rotor Side Converter (RSC) or in the Grid Side Converter (GSC), through the introduction of virtual positive capacitor or virtual negative inductor to reshape the DFIG system impedance and mitigate the high frequency resonance. A detailed theoretical explanation on the virtual positive capacitor...

  8. Short-interval intracortical inhibition is modulated by high-frequency peripheral mixed nerve stimulation.

    Science.gov (United States)

    Murakami, Takenobu; Sakuma, Kenji; Nomura, Takashi; Nakashima, Kenji

    2007-06-01

    Cortical excitability can be modulated by manipulation of afferent input. We investigated the influence of peripheral mixed nerve stimulation on the excitability of the motor cortex. Motor evoked potentials (MEPs), short-interval intracortical inhibition (SICI) and intracortical facilitation (ICF) in the right abductor pollicis brevis (APB), extensor carpi radialis (ECR) and first dorsal interosseous (FDI) muscles were evaluated using paired-pulse transcranial magnetic stimulation (TMS) before and after high-frequency peripheral mixed nerve stimulation (150 Hz, 30 min) over the right median nerve at the wrist. The MEP amplitude and SICI of the APB muscle decreased transiently 0-10 min after the intervention, whereas the ICF did not change. High-frequency peripheral mixed nerve stimulation reduced the excitability of the motor cortex. The decrement in the SICI, which reflects the function of GABA(A)ergic inhibitory interneurons, might compensate for the reduced motor cortical excitability after high-frequency peripheral mixed nerve stimulation.

  9. High-frequency homogenization of zero frequency stop band photonic and phononic crystals

    CERN Document Server

    Antonakakis, Tryfon; Guenneau, Sebastien

    2013-01-01

    We present an accurate methodology for representing the physics of waves, for periodic structures, through effective properties for a replacement bulk medium: This is valid even for media with zero frequency stop-bands and where high frequency phenomena dominate. Since the work of Lord Rayleigh in 1892, low frequency (or quasi-static) behaviour has been neatly encapsulated in effective anisotropic media. However such classical homogenization theories break down in the high-frequency or stop band regime. Higher frequency phenomena are of significant importance in photonics (transverse magnetic waves propagating in infinite conducting parallel fibers), phononics (anti-plane shear waves propagating in isotropic elastic materials with inclusions), and platonics (flexural waves propagating in thin-elastic plates with holes). Fortunately, the recently proposed high-frequency homogenization (HFH) theory is only constrained by the knowledge of standing waves in order to asymptotically reconstruct dispersion curves an...

  10. Effect of ischemia and cooling on the response to high frequency stimulation in rat tail nerves

    DEFF Research Database (Denmark)

    Andersen, Henning; Feldbæk Nielsen, Jørgen; Sørensen, Bodil

    2000-01-01

    In normal rat tail nerves the effect of temperature and ischemia on the response to long-term high frequency stimulation (HFS) (143 Hz) was studied. The effect of temperature was studied in two consecutive tests at 14 degrees C and 35 degrees C. Prior to the HFS the peak-to-peak amplitude (PP-amp...... ischemia to the rat tail, an additional fall of the PP-amp was seen after 15-20 min of HFS at both low (20 Hz) and high (143 Hz) stimulation frequencies. In conclusion, ischemia and cooling result in an impaired ability to transmit high frequency impulses.......In normal rat tail nerves the effect of temperature and ischemia on the response to long-term high frequency stimulation (HFS) (143 Hz) was studied. The effect of temperature was studied in two consecutive tests at 14 degrees C and 35 degrees C. Prior to the HFS the peak-to-peak amplitude (PP...

  11. Advanced waveforms and frequency with spinal cord stimulation: burst and high-frequency energy delivery.

    Science.gov (United States)

    Pope, Jason E; Falowski, Steven; Deer, Tim R

    2015-07-01

    In recent years, software development has been key to the next generation of neuromodulation devices. In this review, we will describe the new strategies for electrical waveform delivery for spinal cord stimulation. A systematic literature review was performed using bibliographic databases, limited to the English language and human data, between 2010 and 2014. The literature search yielded three articles on burst stimulation and four articles on high-frequency stimulation. High-frequency and burst stimulation may offer advantages over tonic stimulation, as data suggest improved patient tolerance, comparable increase in function and possible success with a subset of patients refractory to tonic spinal cord stimulation. High-frequency and burst stimulation are new ways to deliver energy to the spinal cord that may offer advantages over tonic stimulation. These may offer new salvage strategies to mitigate spinal cord stimulation failure and improve cost-effectiveness by reducing explant rate.

  12. Development of High-frequency Soft Magnetic Materials for Power Electronics

    Directory of Open Access Journals (Sweden)

    LIU Jun-chang

    2017-05-01

    Full Text Available The new requirements of high-frequency magnetic properties are put forward for electronic components with the rapid development of power electronics industry and the use of new electromagnetic materials. The properties of magnetic core, which is the key unit of electronic components, determine the performance of electronic components directly. Therefore, it's necessary to study the high-frequency soft magnetic materials. In this paper, the development history of four types of soft magnetic materials was reviewed. The advantages and disadvantages of each kind of soft magnetic materials and future development trends were pointed out. The emphases were placed on the popular soft magnetic composite materials in recent years. The tendency is to develop high-frequency soft magnetic composite materials with the particle size controllable, uniform coating layer on the core and a mass production method from laboratory to industrialization.

  13. High-frequency radar observations of PMSE modulation by radio heating

    Science.gov (United States)

    Senior, Andrew; Rietveld, Michael; Mahmoudian, Alireza; La Hoz, Cesar; Kosch, Michael; Scales, Wayne; Pinedo, Henry

    The first observations using high-frequency (8 MHz) radar of modulation of polar mesospheric summer echoes (PMSE) by radio heating of the ionosphere are presented. The experiment was performed at the EISCAT facility near Tromsø, Norway. The observations are compared with simultaneous radar measurements at 224 MHz and with a model of the dusty plasma response to electron heating. Agreement between the model and observations is good considering technical limitations on the 8 MHz radar measurements. Predictions made about the response of high-frequency PMSE to heating where dust charging dominates over diffusion, opposite to the situation at very high-frequencies are confirmed. Suggestions are made about improving the 8 MHz observations to overcome the current limitations.

  14. Accumulated source imaging of brain activity with both low and high-frequency neuromagnetic signals.

    Science.gov (United States)

    Xiang, Jing; Luo, Qian; Kotecha, Rupesh; Korman, Abraham; Zhang, Fawen; Luo, Huan; Fujiwara, Hisako; Hemasilpin, Nat; Rose, Douglas F

    2014-01-01

    Recent studies have revealed the importance of high-frequency brain signals (>70 Hz). One challenge of high-frequency signal analysis is that the size of time-frequency representation of high-frequency brain signals could be larger than 1 terabytes (TB), which is beyond the upper limits of a typical computer workstation's memory (high-frequency magnetoencephalography (MEG) signals in a single automated and versatile interface, rather than the more traditional, time-intensive visual inspection methods, which may take up to several days. To address the aim, we developed a new method, accumulated source imaging, defined as the volumetric summation of source activity over a period of time. This method analyzes signals in both low- (1~70 Hz) and high-frequency (70~200 Hz) ranges at source levels. To extract meaningful information from MEG signals at sensor space, the signals were decomposed to channel-cross-channel matrix (CxC) representing the spatiotemporal patterns of every possible sensor-pair. A new algorithm was developed and tested by calculating the optimal CxC and source location-orientation weights for volumetric source imaging, thereby minimizing multi-source interference and reducing computational cost. The new method was implemented in C/C++ and tested with MEG data recorded from clinical epilepsy patients. The results of experimental data demonstrated that accumulated source imaging could effectively summarize and visualize MEG recordings within 12.7 h by using approximately 10 GB of computer memory. In contrast to the conventional method of visually identifying multi-frequency epileptic activities that traditionally took 2-3 days and used 1-2 TB storage, the new approach can quantify epileptic abnormalities in both low- and high-frequency ranges at source levels, using much less time and computer memory.

  15. High frequency ultrasound features and pathological characteristics of medullary thyroid carcinoma.

    Science.gov (United States)

    Wang, Hua; Liu, Mengmeng; Yang, Jianqiu; Song, Yimin

    2016-11-01

    To study high-frequency ultrasound features and pathological characteristics of medullary thyroid carcinoma (medullary thyroid carcinoma, MTC) with the purpose to improve the diagnostic accuracy of this disease. The clinical data of 20 cases of patients with MTC confirmed by the clinical surgery were retrospectively analyzed. And the high-frequency ultrasound features were analyzed and compared with the pathological characteristics. There were 16 cases with tumor invasion into one side of the thyroid gland; 17 cases with tumor in the middle-upper pole of the thyroid gland. And 8 cases were detected with uneven echo of high frequency ultrasound appearance and pathological manifestations of cystic degeneration to necrosis seen under the light microscope or normal thyroid tissue within part of the lump. 16 cases were tested with even echo of high frequency ultrasound appearance, and tumor cells were formed in the solid and block-like shape under the light microscope. And 18 cases were manifested with low echo, with proliferation of fibrous tissue within the intercellular substance under the light microscope. 18 cases could be seen the calcification points and often amyloid-like content deposited in the intercellular substance seen under the light microscope. In addition, the pathological manifestations of the 8 cases combined with lymph node metastasis were the "lash tumor" of the metastatic lymph nodes and primary tumor. MTC was commonly located in the middle-upper region of the thyroid gland and in one leaf of the thyroid gland, combined with lymph node metastasis. The high frequency ultrasound appearance was the even low-echo tumor in round or quasi-circular shape, with obscure boundary and often combined with rough calcification. High frequency ultrasound could be used as the prior physical diagnostic method for medullary thyroid carcinoma.

  16. High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,

    Directory of Open Access Journals (Sweden)

    Lucia Bencke Geyer

    2015-12-01

    Full Text Available ABSTRACT INTRODUCTION: The treatment of patients with cystic fibrosis involves the use of ototoxic drugs, mainly aminoglycoside antibiotics. Due to the use of these drugs, fibrocystic patients are at risk of developing hearing loss. OBJECTIVE: To evaluate the hearing of patients with cystic fibrosis by High Frequency Audiometry and Distortion Product Otoacoustic Emissions. METHODS: Cross-sectional study. The study group consisted of 39 patients (7-20 years of age with cystic fibrosis and a control group of 36 individuals in the same age group without otologic complaints, with normal audiometric thresholds and type A tympanometric curves. High Frequency Audiometry and Distortion Product Otoacoustic Emissions tests were conducted. RESULTS: The study group had significantly higher thresholds at 250, 1000, 8000, 9000, 10,000, 12,500, and 16,000 Hz (p = 0.004 as well as higher prevalence of otoacoustic emission alterations at 1000 and 6000 Hz (p = 0.001, with significantly lower amplitudes at 1000, 1400, and 6000 Hz. There was a significant association between alterations in hearing thresholds in High Frequency Audiometry with the number of courses of aminoglycosides administered (p = 0.005. Eighty-three percent of patients who completed more than ten courses of aminoglycosides had hearing loss in High Frequency Audiometry. CONCLUSION: A significant number of patients with cystic fibrosis who received repeated courses of aminoglycosides showed alterations in High Frequency Audiometry and Distortion Product Otoacoustic Emissions. The implementation of ten or more aminoglycoside cycles was associated with alterations in High Frequency Audiometry.

  17. Adaptive Piezoelectric Circuitry Sensor Network with High-Frequency Harmonics Interrogation for Structural Damage Detection

    Science.gov (United States)

    2014-09-17

    AFRL-OSR-VA-TR-2014-0255 ADAPTIVE PIEZOELECTRIC CIRCUITRY SENSOR NETWORK KON-WELL WANG MICHIGAN UNIV ANN ARBOR Final Report 09/17/2014 DISTRIBUTION A...by ANSI Std. Z39.18 09-09-2014 Final Performance Report 06-01-2011 - 05-31-2014 Adaptive Piezoelectric Circuitry Sensor Network with High-Frequency...approach. Specifically, we propose to create a new concept of adaptive high-frequency piezoelectric self-sensing interrogation by means of tunable

  18. A Markov Chain Estimator of Multivariate Volatility from High Frequency Data

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Horel, Guillaume; Lunde, Asger

    We introduce a multivariate estimator of financial volatility that is based on the theory of Markov chains. The Markov chain framework takes advantage of the discreteness of high-frequency returns. We study the finite sample properties of the estimation in a simulation study and apply it to highf......We introduce a multivariate estimator of financial volatility that is based on the theory of Markov chains. The Markov chain framework takes advantage of the discreteness of high-frequency returns. We study the finite sample properties of the estimation in a simulation study and apply...

  19. Efficient Estimation for Diffusions Sampled at High Frequency Over a Fixed Time Interval

    DEFF Research Database (Denmark)

    Jakobsen, Nina Munkholt; Sørensen, Michael

    Parametric estimation for diffusion processes is considered for high frequency observations over a fixed time interval. The processes solve stochastic differential equations with an unknown parameter in the diffusion coefficient. We find easily verified conditions on approximate martingale...... estimating functions under which estimators are consistent, rate optimal, and efficient under high frequency (in-fill) asymptotics. The asymptotic distributions of the estimators are shown to be normal variance-mixtures, where the mixing distribution generally depends on the full sample path of the diffusion...

  20. Determination of the High Frequency Inductance Profile of Surface Mounted Permanent Magnet Synchronous Motors

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Ritchie, Ewen

    2008-01-01

    Accurate knowledge of the high frequency inductance profile plays an important role in many designs of sensorless controllers for Surface inductance. A special algorithm is used to decouple the cross-coupling effects between the d-axis and the q-axis, which allows Mounted Permanent Magnet (SMPM......) synchronous motors. This paper presents an AC+DC measurement method for determination of the d-axis and q-axis high frequency inductance profiles of SMPM synchronous motors. This method uses DC currents to set a desired magnetic working point on the motor laminations, and then superimpose balanced small AC...

  1. Interference Dynamics of Hydrogen Atoms in High-Frequency Dichromatic Laser Fields

    Science.gov (United States)

    Cheng, Tai-Wang; Li, Xiao-Feng; Fu, Pan-Ming; Chen, Shi-Gang

    2002-08-01

    We investigate the ionization and high-order harmonic generation of a hydrogen atom in high-frequency (several atomic units) super strong (up to several tens of atomic units) dichromatic laser fields. An effective iterative method in the framework of high-frequency Floquet theory is used in the calculations. We have considered two kinds of dichromatic laser field, i.e. 1ω-2ω and 1ω-3ω. We find that, in both the cases, the ionization and high-order harmonic generation show evident dependence on the relative phase and strength of the additional harmonic field. The dynamical origin of these interference effects is also discussed.

  2. Interference Dynamics of Hydrogen Atoms in High-Frequency Dichromatic Laser Fields

    Institute of Scientific and Technical Information of China (English)

    程太旺; 李晓峰; 傅盘铭; 陈式刚

    2002-01-01

    We investigate the ionization and high-order harmonic generation of a hydrogen atom in high-frequency (several atomic units) super strong (up to several tens of atomic units) dichromatic laser fields. An effective iterative method in the framework of high-frequency Floquet theory is used in the calculations. We have considered two kinds of dichromatic laser field, i.e. 1ω - 2ω and lω - 3ω. We find that, in both the cases, the ionization and high-order harmonic generation show evident dependence on the relative phase and strength of the additional harmonic field. The dynamical origin of these interference effects is also discussed.

  3. Designing All-Pole Filters for High-Frequency Phase-Locked Loops

    Directory of Open Access Journals (Sweden)

    Ricardo Bressan Pinheiro

    2014-01-01

    signals exchanged between the nodes of the networks and detected by PLLs. The necessity to improve clock precision that follows the bandwidth increase provoked the improvement of the filter component of the PLLs, avoiding instability and high-frequency components in the reference signals. Here, a technique of designing this kind of filter is presented, considering second-order filters, implying third-order PLLs. Simulations show that following this technique produces very fast tracking processes, enabling precise operation even for very high frequencies.

  4. Effective market influence. An effect chain analysis of NUTEK`s high-frequency lighting campaign

    Energy Technology Data Exchange (ETDEWEB)

    Goeransson, C.; Faugert, S. [SIPU Utvaerdering, Stockholm (Sweden); Baeckman, B.; Arndt, J. [B2B AB, Stockholm (Sweden)

    1994-12-31

    This report is an evaluation of NUTEK`s `Better lighting and more energy-efficient high-frequency fluorescent tube luminaries` campaign. It is concerned with the ways in which NUTEK can influence the spread and use of high-frequency (HF) lighting devices. It also shows that NUTEK actually has affected (contributed to) development in the area. The report analyses and quantifies (as far as possible) how much NUTEK has influenced the various parties concerned in the sector, their attitudes and their actions. 14 figs, 5 tabs

  5. Effectiveness of treatment with high-frequency chest wall oscillation in patients with bronchiectasis

    OpenAIRE

    Nicolini, Antonello; Cardini, Federica; Landucci, Norma; Lanata, Sergio; Ferrari-Bravo, Maura; Barlascini, Cornelius

    2013-01-01

    Background High-frequency airway clearance (HFCWC) assist devices generate either positive or negative trans-respiratory pressure excursions to produce high-frequency, small-volume oscillations in the airways. HFCWC can lead to changes in volume of 15–57 ml and in flow up to 1.6 L/s, which generate minimal coughing to mobilize secretions. The typical treatment lasts 20–30 minutes, and consists of short periods of compression at different frequencies, separated by coughing. The aim of this stu...

  6. A Realized Variance for the Whole Day Based on Intermittent High-Frequency Data

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Lunde, Asger

    2005-01-01

    We consider the problem of deriving an empirical measure of daily integrated variance (IV) in the situation where high-frequency price data are unavailable for part of the day. We study three estimators in this context and characterize the assumptions that justify their use. We show that the opti......We consider the problem of deriving an empirical measure of daily integrated variance (IV) in the situation where high-frequency price data are unavailable for part of the day. We study three estimators in this context and characterize the assumptions that justify their use. We show...

  7. A Pitch Extraction Method with High Frequency Resolution for Singing Evaluation

    Science.gov (United States)

    Takeuchi, Hideyo; Hoguro, Masahiro; Umezaki, Taizo

    This paper proposes a pitch estimation method suitable for singing evaluation incorporable in KARAOKE machines. Professional singers and musicians have sharp hearing for music and singing voice. They recognize that singer's voice pitch is “a little off key” or “be in tune”. In the same way, the pitch estimation method that has high frequency resolution is necessary in order to evaluate singing. This paper proposes a pitch estimation method with high frequency resolution utilizing harmonic characteristic of autocorrelation function. The proposed method can estimate a fundamental frequency in the range 50 ∼ 1700[Hz] with resolution less than 3.6 cents in light processing.

  8. Adaptive control of linear multivariable systems with high frequency gain matrix hurwitz

    Institute of Scientific and Technical Information of China (English)

    Ying ZHOU; Yuqiang WU; Shumin FEI

    2005-01-01

    A new adaptive control scheme is proposed for multivariable model reference adaptive control(MRAC) systems based on the nonlinear backstepping approach with vector form.The assumption on a priori knowledge of the high frequency gain matrix in existing results is relaxed and the new required condition for the high frequency gain matrix can be easily checked for certain plants so that the proposed method is widely applicable.This control scheme guarantees the global stability of the closed-loop systems and the tracking error can be arbitrary small.The simulation result for an application example shows the validity of the proposed nonlinear adaptive scheme.

  9. Casimir force between $\\delta-\\delta^{\\prime}$ mirrors transparent at high frequencies

    CERN Document Server

    Braga, Alessandra N; Alves, Danilo T

    2016-01-01

    We investigate, in the context of a real massless scalar field in $1+1$ dimensions, models of partially reflecting mirrors simulated by Dirac $\\delta-\\delta^{\\prime}$ point interactions. In the literature, these models do not exhibit full transparency at high frequencies. In order to provide a more realistic feature for these models, we propose a modified $\\delta-\\delta^{\\prime}$ point interaction that enables to achieve full transparency in the limit of high frequencies. Taking this modified $\\delta-\\delta^{\\prime}$ model into account, we investigate the Casimir force, comparing our results with those found in the literature.

  10. Required changes in emission standards for high-frequency noise in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Lundmark, C.M.; Larsson, E.O.A. [Lulea Univ. of Technology, Skelleftea (Sweden); Bollen, M.H.J. [STRI AB, Ludvika (Sweden)

    2006-07-01

    This paper discusses some recent developments that make the existing standards on the emission of high-frequency noise in power systems due for reconsideration. It is shown that it is possible for an equipment to remain below the emission limits while at the same time the disturbance level increases beyond what was intended by the standard document. Further, the change from analog to digital communication and the use of communication via the power system, make that the permitted disturbance levels need to be reconsidered. This paper also contains an example of measured high-frequency noise and proposes a framework for re-coordination of emission and immunity levels. (Author)

  11. High-frequency impedance of small-angle tapers and collimators

    Directory of Open Access Journals (Sweden)

    G. Stupakov

    2010-10-01

    Full Text Available Collimators and transitions in accelerator vacuum chambers often include small-angle tapering to lower the wakefields generated by the beam. While the low-frequency impedance is well described by Yokoya’s formula (for axisymmetric geometry, much less is known about the behavior of the impedance in the high-frequency limit. In this paper we develop an analytical approach to the high-frequency regime for round collimators and tapers. Our analytical results are compared with computer simulations using the code ECHO.

  12. Passive ultrasonics using sub-Nyquist sampling of high-frequency thermal-mechanical noise.

    Science.gov (United States)

    Sabra, Karim G; Romberg, Justin; Lani, Shane; Degertekin, F Levent

    2014-06-01

    Monolithic integration of capacitive micromachined ultrasonic transducer arrays with low noise complementary metal oxide semiconductor electronics minimizes interconnect parasitics thus allowing the measurement of thermal-mechanical (TM) noise. This enables passive ultrasonics based on cross-correlations of diffuse TM noise to extract coherent ultrasonic waves propagating between receivers. However, synchronous recording of high-frequency TM noise puts stringent requirements on the analog to digital converter's sampling rate. To alleviate this restriction, high-frequency TM noise cross-correlations (12-25 MHz) were estimated instead using compressed measurements of TM noise which could be digitized at a sampling frequency lower than the Nyquist frequency.

  13. New considerations concerning the high-frequency focusing of relativistic particles and Panofsky-Wenzel theorem

    Science.gov (United States)

    Melekhin, V. N.

    1997-02-01

    It is shown that the transverse momentum imparted to a relativistic particle, passing through an accelerating cavity near and parallel to its axis ( z-axis), may be presented as a trajectory integral with an integrand being proportional to z-component of high-frequency magnetic field. The x- and y-component of this momentum are equal in value but opposite in sign. The obtained result is compared with Panofsky-Wenzel theorem. This result gives one more procedure to check the accuracy of high-frequency focusing simulation.

  14. Realistic simulations of tsunami detection by High-Frequency Radar in British Columbia, Canada

    Science.gov (United States)

    Grilli, Stéphan; Shelby, Michael; Grilli, Annette; Lado Insua, Tania; Guérin, Charles-Antoine

    2016-04-01

    A promising technique for long-range detection of tsunamis is the use of shore-based High Frequency (HF) surface wave radars, also simply referred to as oceanographic radars. These over-the-horizon radars are routinely used for real-time monitoring of ocean surface currents up to a 70-80 km range, based on the Doppler shift the latter cause in ocean waves at the radar Bragg frequency. Quite recently there has been convincing numerical and experimental evidence that oceanographic radars can also be used to detect tsunami-induced surface currents. However, these need to be at least 0.15-0.20 m/s to be detectable, when considering environmental noise and background currents (from tide and mesoscale circulation). This limits the actual detection of tsunami currents to the near range, that is essentially to the continental shelf over which tsunami currents become strong enough; in many cases this does not leave enough time to issue an efficient warning, unless there is a wide shelf. In recent work, some of the authors have proposed a detection algorithm that does not have this limitation and can detect an approaching tsunami in deeper water, beyond the continental shelf. This algorithm does not require "inverting" currents, but instead is based on spatial correlations of the raw signals recorded at two distant radar cells along the same wave ray, shifted in time by the tsunami propagation time along the ray. An elevated correlation would indicate the presence of a tsunami. We apply this algorithm to a realistic tsunami case study conducted, using a state-of-the-art long wave model, for sources (both seismic and landslide) and bathymetry off of Vancouver Island, BC. The propagation time between different radar cells is calculated with a Geometrical Optics approach using the Eikonal equation. This requires first determining wave rays' intersections with radar cells and computing a connectivity matrix between the latter. A model simulating the radar backscattered signal in

  15. Obliquity Variations of a Potentially Habitable Early Venus

    Science.gov (United States)

    Barnes, Jason W.; Quarles, Billy L.; Lissauer, Jack J.; Chambers, John E.; Hedman, Matthew M.

    2016-06-01

    Planetary obliquity (axis tilt) and its variations can have strong effects on climate. Earth's glacial cycles, for instance, are driven in part by variations in Earth's obliquity of order ±1.5o. Direct observations of the obliquity of habitable zone rocky exoplanets is likely a long way off. Therefore we investigate the long-term obliquity variations expected for Venus as it might have existed in the early Solar System. Although Venus presently rotates slowly owing to tidal despinning, it must have had a different rotation state early in Solar System history. At the same time, Venus was the Solar System's habitable zone under a Faint Young Sun. Because of our extensive knowledge of the Solar System's constituents, we therefore use Venus' obliquity variations as a proxy for what we might find in exoplanetary systems. We find that the obliquity variation structure is simpler for early Venus than it would be for a Moonless Earth, but that large, chaotic variability can occur for high initial obliquity values. Interestingly retrograde-rotating Venuses show higher variability than do retrograde Moonless Earths.

  16. Obliquity evolution of the minor satellites of Pluto and Charon

    Science.gov (United States)

    Quillen, Alice C.; Nichols-Fleming, Fiona; Chen, Yuan-Yuan; Noyelles, Benoît

    2017-09-01

    New Horizons mission observations show that the small satellites Styx, Nix, Kerberos and Hydra, of the Pluto-Charon system, have not tidally spun-down to near synchronous spin states and have high obliquities with respect to their orbit about the Pluto-Charon binary (Weaver, 2016). We use a damped mass-spring model within an N-body simulation to study spin and obliquity evolution for single spinning non-round bodies in circumbinary orbit. Simulations with tidal dissipation alone do not show strong obliquity variations from tidally induced spin-orbit resonance crossing and this we attribute to the high satellite spin rates and low orbital eccentricities. However, a tidally evolving Styx exhibits intermittent obliquity variations and episodes of tumbling. During a previous epoch where Charon migrated away from Pluto, the minor satellites could have been trapped in orbital mean motion inclination resonances. An outward migrating Charon induces large variations in Nix and Styx's obliquities. The cause is a commensurability between the mean motion resonance frequency and the spin precession rate of the spinning body. As the minor satellites are near mean motion resonances, this mechanism could have lifted the obliquities of all four minor satellites. The high obliquities need not be primordial if the minor satellites were at one time captured into mean motion resonances.

  17. Modelling Steep Surfaces by Various Configurations of Nadir and Oblique Photogrammetry

    Science.gov (United States)

    Casella, V.; Franzini, M.

    2016-06-01

    Among the parts of the territory requiring periodical and careful monitoring, many have steep surfaces: quarries, river basins, land-slides, dangerous mountainsides. Aerial photogrammetry based on lightweight unmanned aircraft systems (UAS) is rapidly becoming the tool of election to survey limited areas of land with a high level of detail. Aerial photogrammetry is traditionally based on vertical images and only recently the use of significantly inclined imagery has been considered. Oblique photogrammetry presents peculiar aspects and offers improved capabilities for steep surface reconstruction. Full comprehension of oblique photogrammetry still requires research efforts and the evaluation of diverse case studies. In the present paper, the focus is on the photogrammetric UAS-based survey of a part of a large sandpit. Various flight configurations are considered: ordinary linear strips, radial strips (as the scarp considered has a semi-circular shape) and curved ones; moreover, nadir looking and oblique image blocks were acquired. Around 300 control points were measured with a topographic total station. The various datasets considered are evaluated in terms of density of the extracted point cloud and in terms of the distance between the reconstructed surface and a number of check points.

  18. High frequency pulse anodising of magnetron sputtered Al–Zr and Al–Ti Coatings

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Bordo, Kirill; Engberg, Sara

    2016-01-01

    High frequency pulse anodising of Al–Zr and Al–Ti coatings is studied as a surface finishing technique and compared to conventional decorative DC anodising. The Al–Zr and Al–Ti coatings were deposited using DC magnetron sputtering and were heat treated after deposition to generate a multiphase mi...

  19. Single phase AC-DC power factor corrected converter with high frequency isolation using buck converter

    Directory of Open Access Journals (Sweden)

    R. Ramesh,

    2014-03-01

    Full Text Available Single phase ac-dc converters having high frequency isolation are implemented in buck, boost, buck-boost configuration with improving the power quality in terms of reducing the harmonics of input current. The paperpropose the circuit configuration, control mechanism, and simulation result for the single phase ac-dc converter.

  20. Effectiveness of a prolonged incarceration and rehabilitation measure for high-frequency offenders

    NARCIS (Netherlands)

    Tollenaar, N.; van der Laan, A. M.; van der Heijden, P. G M

    2014-01-01

    Objectives: To estimate the incapacitation effect and the impact on post-release recidivism of a measure combining prolonged incarceration and rehabilitation, the ISD measure for high frequency offenders (HFOs) was compared to the standard practice of short-term imprisonment. Methods: We applied a q