WorldWideScience

Sample records for monitor multiple simultaneous

  1. Simultaneous real-time monitoring of multiple cortical systems.

    Science.gov (United States)

    Gupta, Disha; Jeremy Hill, N; Brunner, Peter; Gunduz, Aysegul; Ritaccio, Anthony L; Schalk, Gerwin

    2014-10-01

    Real-time monitoring of the brain is potentially valuable for performance monitoring, communication, training or rehabilitation. In natural situations, the brain performs a complex mix of various sensory, motor or cognitive functions. Thus, real-time brain monitoring would be most valuable if (a) it could decode information from multiple brain systems simultaneously, and (b) this decoding of each brain system were robust to variations in the activity of other (unrelated) brain systems. Previous studies showed that it is possible to decode some information from different brain systems in retrospect and/or in isolation. In our study, we set out to determine whether it is possible to simultaneously decode important information about a user from different brain systems in real time, and to evaluate the impact of concurrent activity in different brain systems on decoding performance. We study these questions using electrocorticographic signals recorded in humans. We first document procedures for generating stable decoding models given little training data, and then report their use for offline and for real-time decoding from 12 subjects (six for offline parameter optimization, six for online experimentation). The subjects engage in tasks that involve movement intention, movement execution and auditory functions, separately, and then simultaneously. Main Results: Our real-time results demonstrate that our system can identify intention and movement periods in single trials with an accuracy of 80.4% and 86.8%, respectively (where 50% would be expected by chance). Simultaneously, the decoding of the power envelope of an auditory stimulus resulted in an average correlation coefficient of 0.37 between the actual and decoded power envelopes. These decoders were trained separately and executed simultaneously in real time. This study yielded the first demonstration that it is possible to decode simultaneously the functional activity of multiple independent brain systems. Our

  2. A yeast screening system for simultaneously monitoring multiple genetic endpoints

    International Nuclear Information System (INIS)

    Dixon, M.L.; Mortimer, R.K.

    1986-01-01

    Mutation, recombination, and mitochondrial deficiencies have been proposed to have roles in the carcinogenic process. The authors describe a diploid strain of the yeast Saccharomyces cerevisiae capable of detecting this wide spectrum of genetic changes. The markers used for monitoring these events have been especially well characterized genetically. Ultraviolet light was chosen as a model carcinogenic agent to test this system. In addition to highly significant increases in the frequencies of each genetic change, increases in the absolute numbers of each change indicated induction and not selective survival. The relative amounts of each type of genetic change varied with dose. The wide spectrum of endpoints monitored in the XD83 yeast system may allow the detection of certain carcinogens and other genetically toxic agents which have escaped detection in more limited systems. Since only one strain is required to simultaneously monitor these genetic changes, this assay system should facilitate comparisons of the induced changes and be more efficient than using multiple strains to monitor the same endpoints. (Auth.)

  3. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

    Science.gov (United States)

    Choi, Yong Seok; Lee, Kelvin H

    2016-03-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.

  4. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: Simultaneous oxygen and pH monitoring

    International Nuclear Information System (INIS)

    Liu, Rui; Xiao, Teng; Cui, Weipan; Shinar, Joseph; Shinar, Ruth

    2013-01-01

    Graphical abstract: -- Highlights: •Novel simply-fabricated all-organic electronics pH and oxygen optical monitor. •Excitation sources: directionally emitting, narrowed multicolor microcavity OLEDs. •Photodetectors: small molecule- or polymer-based with selective spectral responses. •Sensor film: structured high molecular weight polystyrene:polyethylene glycol blend. •×1.9 sensitivity enhancement and ×2.7 increase in the photoluminescence for oxygen. -- Abstract: Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs’ broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ∼20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ 0 /τ 100 (PL decay time τ at 0% O 2 /τ at 100% O 2 ) that is often used to express S

  5. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: simultaneous oxygen and pH monitoring.

    Science.gov (United States)

    Liu, Rui; Xiao, Teng; Cui, Weipan; Shinar, Joseph; Shinar, Ruth

    2013-05-17

    Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs' broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ~20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ0/τ100 (PL decay time τ at 0% O2/τ at 100% O2) that is often used to express S increases ×1.9 to 20.7 relative to the lower molecular weight PS, where this ratio is 11.0. This increase reduces to ×1.7 when the PEG is added (τ0/τ100=18.2), but the latter results in an increase ×2.7 in the PL intensity. The sensor's response time is <10s in all cases. The microporous structure of these blended films, with PEG decorating PS pores, serves a dual purpose. It results in light scattering that reduces the EL that is waveguided in the substrate of the OLEDs and

  6. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: Simultaneous oxygen and pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Rui; Xiao, Teng; Cui, Weipan [Ames Laboratory-USDOE and Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Shinar, Joseph, E-mail: jshinar@iastate.edu [Ames Laboratory-USDOE and Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Shinar, Ruth, E-mail: rshinar@iastate.edu [Microelectronics Research Center and Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011 (United States)

    2013-05-17

    Graphical abstract: -- Highlights: •Novel simply-fabricated all-organic electronics pH and oxygen optical monitor. •Excitation sources: directionally emitting, narrowed multicolor microcavity OLEDs. •Photodetectors: small molecule- or polymer-based with selective spectral responses. •Sensor film: structured high molecular weight polystyrene:polyethylene glycol blend. •×1.9 sensitivity enhancement and ×2.7 increase in the photoluminescence for oxygen. -- Abstract: Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs’ broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ∼20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ{sub 0}/τ{sub 100} (PL decay time τ at 0% O{sub 2}/τ at 100% O{sub 2}) that is often used

  7. Simultaneous Quantification of Apolipoprotein A-I and Apolipoprotein B by Liquid-Chromatography–Multiple-Reaction–Monitoring Mass Spectrometry

    Science.gov (United States)

    Agger, Sean A.; Marney, Luke C.; Hoofnagle, Andrew N.

    2011-01-01

    BACKGROUND If liquid-chromatography–multiple-reaction–monitoring mass spectrometry (LC-MRM/MS) could be used in the large-scale preclinical verification of putative biomarkers, it would obviate the need for the development of expensive immunoassays. In addition, the translation of novel biomarkers to clinical use would be accelerated if the assays used in preclinical studies were the same as those used in the clinical laboratory. To validate this approach, we developed a multiplexed assay for the quantification of 2 clinically well-known biomarkers in human plasma, apolipoprotein A-I and apolipoprotein B (apoA-I and apoB). METHODS We used PeptideAtlas to identify candidate peptides. Human samples were denatured with urea or trifluoroethanol, reduced and alkylated, and digested with trypsin. We compared reversed-phase chromatographic separation of peptides with normal flow and microflow, and we normalized endogenous peptide peak areas to internal standard peptides. We evaluated different methods of calibration and compared the final method with a nephelometric immunoassay. RESULTS We developed a final method using trifluoroethanol denaturation, 21-h digestion, normal flow chromatography-electrospray ionization, and calibration with a single normal human plasma sample. For samples injected in duplicate, the method had intraassay CVs <6% and interassay CVs <12% for both proteins, and compared well with immunoassay (n = 47; Deming regression, LC-MRM/MS = 1.17 × immunoassay – 36.6; Sx|y = 10.3 for apoA-I and LC-MRM/MS = 1.21 × immunoassay + 7.0; Sx|y = 7.9 for apoB). CONCLUSIONS Multiplexed quantification of proteins in human plasma/serum by LC-MRM/MS is possible and compares well with clinically useful immunoassays. The potential application of single-point calibration to large clinical studies could simplify efforts to reduce day-to-day digestion variability. PMID:20923952

  8. High-resolution continuum source atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple lines. A critical review of current possibilities

    International Nuclear Information System (INIS)

    Resano, M.; Flórez, M.R.; García-Ruiz, E.

    2013-01-01

    This work examines the capabilities and limitations of commercially available high-resolution continuum source atomic absorption spectrometry instrumentation for multi-line monitoring, discussing in detail the possible strategies to develop multi-element methodologies that are truly simultaneous, or else sequential, but from the same sample aliquot. Moreover, the simultaneous monitoring of various atomic or molecular lines may bring other important analytical advantages, such as: i) expansion of the linear range by monitoring multiplets; ii) improvements in the limit of detection and in precision by summing the signals from different lines of the same element or molecule; iii) simple correction for matrix-effects by selecting a suitable internal standard; or iv) accurate mathematical correction of spectral overlaps by simultaneous monitoring of free lines of the interfering molecule or element. This work discusses how authors have made use of these strategies to develop analytical methodologies that permit the straightforward analysis of complex samples. - Highlights: • HR CS AAS potential for simultaneous multi-line monitoring is critically examined. • Strategies to develop simultaneous multi-element methods are discussed. • Other benefits of multi-line monitoring (e.g., use of an IS or LSBC) are highlighted. • Selected examples from the literature are discussed in detail

  9. Sequential and simultaneous multiple explanation

    Directory of Open Access Journals (Sweden)

    Robert Litchfield

    2007-02-01

    Full Text Available This paper reports two experiments comparing variants of multiple explanation applied in the early stages of a judgment task (a case involving employee theft where participants are not given a menu of response options. Because prior research has focused on situations where response options are provided to judges, we identify relevant dependent variables that an intervention might affect when such options are not given. We use these variables to build a causal model of intervention that illustrates both the intended effects of multiple explanation and some potentially competing processes that it may trigger. Although multiple explanation clearly conveys some benefits (e.g., willingness to delay action to engage in information search, increased detail, quality and confidence in alternative explanations in the present experiments, we also found evidence that it may initiate or enhance processes that attenuate its advantages (e.g., feelings that one does not need more data if one has multiple good explanations.

  10. On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines

    International Nuclear Information System (INIS)

    Resano, M.; Rello, L.; Florez, M.; Belarra, M.A.

    2011-01-01

    This paper explores the potential of commercially available high-resolution continuum source graphite furnace atomic absorption spectrometry instrumentation for the simultaneous or sequential monitoring of various atomic lines, in an attempt to highlight the analytical advantages that can be derived from this strategy. In particular, it is demonstrated how i) the monitoring of multiplets may allow for the simple expansion of the linear range, as shown for the measurement of Ni using the triplet located in the vicinity of 234.6 nm; ii) the use of a suitable internal standard may permit improving the precision and help in correcting for matrix-effects, as proved for the monitoring of Ni in different biological samples; iii) direct and multi-element analysis of solid samples may be feasible on some occasions, either by monitoring various atomic lines that are sufficiently close (truly simultaneous monitoring, as demonstrated in the determination of Co, Fe and Ni in NIST 1566a Oyster tissue) or, alternatively, by opting for a selective and sequential atomization of the elements of interest during every single replicate. Determination of Cd and Ni in BCR 679 White cabbage is attempted using both approaches, which permits confirming that both methods can offer very similar and satisfactory results. However, it is important to stress that the second approach provides more flexibility, since analysis is no longer limited to those elements that show very close atomic lines (closer than 0.3 nm in the ultraviolet region) with a sensitivity ratio similar to the concentration ratio of the analytes in the samples investigated.

  11. Simultaneous gene finding in multiple genomes.

    Science.gov (United States)

    König, Stefanie; Romoth, Lars W; Gerischer, Lizzy; Stanke, Mario

    2016-11-15

    As the tree of life is populated with sequenced genomes ever more densely, the new challenge is the accurate and consistent annotation of entire clades of genomes. We address this problem with a new approach to comparative gene finding that takes a multiple genome alignment of closely related species and simultaneously predicts the location and structure of protein-coding genes in all input genomes, thereby exploiting negative selection and sequence conservation. The model prefers potential gene structures in the different genomes that are in agreement with each other, or-if not-where the exon gains and losses are plausible given the species tree. We formulate the multi-species gene finding problem as a binary labeling problem on a graph. The resulting optimization problem is NP hard, but can be efficiently approximated using a subgradient-based dual decomposition approach. The proposed method was tested on whole-genome alignments of 12 vertebrate and 12 Drosophila species. The accuracy was evaluated for human, mouse and Drosophila melanogaster and compared to competing methods. Results suggest that our method is well-suited for annotation of (a large number of) genomes of closely related species within a clade, in particular, when RNA-Seq data are available for many of the genomes. The transfer of existing annotations from one genome to another via the genome alignment is more accurate than previous approaches that are based on protein-spliced alignments, when the genomes are at close to medium distances. The method is implemented in C ++ as part of Augustus and available open source at http://bioinf.uni-greifswald.de/augustus/ CONTACT: stefaniekoenig@ymail.com or mario.stanke@uni-greifswald.deSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. High resolution and simultaneous monitoring of airborne radionuclides

    International Nuclear Information System (INIS)

    Abe, T.; Yamaguchi, Y.; Muguntha Manikandan, N.; Komura, K.

    2005-01-01

    By using 11 extremely low background Ge detectors at Ogoya Underground Laboratory, it became possible to investigate temporal variations of airborne 212 Pb (T 1/2 =10.6 h) along with 210 Pb and 7 Be with order of magnitude higher time resolution. Then, we have measured airborne nuclides at three monitoring points, (1) roof of our laboratory (LLRL; 40 m ASL), (2) Shinshiku Plateau (640 m ASL) located about 8 km from LLRL as a comparison of vertical distribution, and (3) Hegura Island (10 m ASL) at about 50 km from Wajima located north of Noto Peninsula facing on the Sea of Japan (about 180 km to the north-northeast of LLRL), to investigate influence of Asian continent. Airborne nuclides were collected by high volume air samplers at intervals of a few hours at either two or three points simultaneously. In the same manner, high resolution monitoring was carried out also at the time of passage of typhoon and cold front. In this study, we observed drastic temporal variations of airborne radionuclides and correlations of multiple monitoring points. The results indicate that high resolution and simultaneous monitoring is very useful to understand dynamic state of variations of airborne nuclides due to short and long-term air-mass movement. (author)

  13. Simultaneous Multiple-Location Separation Control

    Science.gov (United States)

    Greenblatt, David (Inventor)

    2009-01-01

    A method of controlling a shear layer for a fluid dynamic body introduces first periodic disturbances into the fluid medium at a first flow separation location. Simultaneously, second periodic disturbances are introduced into the fluid medium at a second flow separation location. A phase difference between the first and second periodic disturbances is adjusted to control flow separation of the shear layer as the fluid medium moves over the fluid dynamic body.

  14. Multiple simultaneous event model for radiation carcinogenesis

    International Nuclear Information System (INIS)

    Baum, J.W.

    1976-01-01

    A mathematical model is proposed which postulates that cancer induction is a multi-event process, that these events occur naturally, usually one at a time in any cell, and that radiation frequently causes two of these events to occur simultaneously. Microdosimetric considerations dictate that for high LET radiations the simultaneous events are associated with a single particle or track. The model predicts: (a) linear dose-effect relations for early times after irradiation with small doses, (b) approximate power functions of dose (i.e. Dsup(x)) having exponent less than one for populations of mixed age examined at short times after irradiation with small doses, (c) saturation of effect at either long times after irradiation with small doses or for all times after irradiation with large doses, and (d) a net increase in incidence which is dependent on age of observation but independent of age at irradiation. Data of Vogel, for neutron induced mammary tumors in rats, are used to illustrate the validity of the formulation. This model provides a quantitative framework to explain several unexpected results obtained by Vogel. It also provides a logical framework to explain the dose-effect relations observed in the Japanese survivors of the atomic bombs. (author)

  15. Multiple simultaneous fabrication of molecular nanowires using nanoscale electrocrystallization

    International Nuclear Information System (INIS)

    Hasegawa, Hiroyuki; Ueda, Rieko; Kubota, Tohru; Mashiko, Shinro

    2006-01-01

    We carried out a multiple simultaneous fabrication based on the nanoscale electrocrystallization to simultaneously construct molecular nanowires at two or more positions. This substrate-independent nanoscale electrocrystallization process enables nanowires fabrication at specific positions using AC. We also succeeded in multiple fabrications only at each gap between the electrode tips. We found that π-stack was formed along the long axis of the nanowires obtained by analyzing the selected-area electron diffraction. We believe this technique has the potential for expansion to the novel low-cost and energy-saving fabrication of high-performance nanodevices

  16. Simultaneous excitation system for efficient guided wave structural health monitoring

    Science.gov (United States)

    Hua, Jiadong; Michaels, Jennifer E.; Chen, Xin; Lin, Jing

    2017-10-01

    Many structural health monitoring systems utilize guided wave transducer arrays for defect detection and localization. Signals are usually acquired using the ;pitch-catch; method whereby each transducer is excited in turn and the response is received by the remaining transducers. When extensive signal averaging is performed, the data acquisition process can be quite time-consuming, especially for metallic components that require a low repetition rate to allow signals to die out. Such a long data acquisition time is particularly problematic if environmental and operational conditions are changing while data are being acquired. To reduce the total data acquisition time, proposed here is a methodology whereby multiple transmitters are simultaneously triggered, and each transmitter is driven with a unique excitation. The simultaneously transmitted waves are captured by one or more receivers, and their responses are processed by dispersion-compensated filtering to extract the response from each individual transmitter. The excitation sequences are constructed by concatenating a series of chirps whose start and stop frequencies are randomly selected from a specified range. The process is optimized using a Monte-Carlo approach to select sequences with impulse-like autocorrelations and relatively flat cross-correlations. The efficacy of the proposed methodology is evaluated by several metrics and is experimentally demonstrated with sparse array imaging of simulated damage.

  17. LIKELIHOOD ESTIMATION OF PARAMETERS USING SIMULTANEOUSLY MONITORED PROCESSES

    DEFF Research Database (Denmark)

    Friis-Hansen, Peter; Ditlevsen, Ove Dalager

    2004-01-01

    The topic is maximum likelihood inference from several simultaneously monitored response processes of a structure to obtain knowledge about the parameters of other not monitored but important response processes when the structure is subject to some Gaussian load field in space and time. The consi....... The considered example is a ship sailing with a given speed through a Gaussian wave field....

  18. Mirrored pyramidal wells for simultaneous multiple vantage point microscopy.

    Science.gov (United States)

    Seale, K T; Reiserer, R S; Markov, D A; Ges, I A; Wright, C; Janetopoulos, C; Wikswo, J P

    2008-10-01

    We report a novel method for obtaining simultaneous images from multiple vantage points of a microscopic specimen using size-matched microscopic mirrors created from anisotropically etched silicon. The resulting pyramidal wells enable bright-field and fluorescent side-view images, and when combined with z-sectioning, provide additional information for 3D reconstructions of the specimen. We have demonstrated the 3D localization and tracking over time of the centrosome of a live Dictyostelium discoideum. The simultaneous acquisition of images from multiple perspectives also provides a five-fold increase in the theoretical collection efficiency of emitted photons, a property which may be useful for low-light imaging modalities such as bioluminescence, or low abundance surface-marker labelling.

  19. Structured plant metabolomics for the simultaneous exploration of multiple factors.

    Science.gov (United States)

    Vasilev, Nikolay; Boccard, Julien; Lang, Gerhard; Grömping, Ulrike; Fischer, Rainer; Goepfert, Simon; Rudaz, Serge; Schillberg, Stefan

    2016-11-17

    Multiple factors act simultaneously on plants to establish complex interaction networks involving nutrients, elicitors and metabolites. Metabolomics offers a better understanding of complex biological systems, but evaluating the simultaneous impact of different parameters on metabolic pathways that have many components is a challenging task. We therefore developed a novel approach that combines experimental design, untargeted metabolic profiling based on multiple chromatography systems and ionization modes, and multiblock data analysis, facilitating the systematic analysis of metabolic changes in plants caused by different factors acting at the same time. Using this method, target geraniol compounds produced in transgenic tobacco cell cultures were grouped into clusters based on their response to different factors. We hypothesized that our novel approach may provide more robust data for process optimization in plant cell cultures producing any target secondary metabolite, based on the simultaneous exploration of multiple factors rather than varying one factor each time. The suitability of our approach was verified by confirming several previously reported examples of elicitor-metabolite crosstalk. However, unravelling all factor-metabolite networks remains challenging because it requires the identification of all biochemically significant metabolites in the metabolomics dataset.

  20. Measuring multiple nano-textured areas simultaneously with imaging scatterometry

    DEFF Research Database (Denmark)

    Madsen, Jonas Skovlund; Hansen, Poul Erik; Bilenberg, Brian

    2017-01-01

    and areas with defects can be avoided. These advantages make imaging scatterometry a very effective and user-friendly characterization method and allow us to determine the homogeneity of a nano- Textured surface by performing pixel-wise analyses. In the analysis an inverse modelling approach is used, where...... measured diffraction efficiencies are compared to simulated diffraction efficiencies using a least-square fitting approach. We demonstrate an imaging scatterometry setup built into an optical microscope. The setup is capable of measuring multiple 2D gratings with pitches of 200 nm simultaneously...

  1. Negotiating for more: the multiple equivalent simultaneous offer.

    Science.gov (United States)

    Heller, Richard E

    2014-02-01

    Whether a doctor, professional baseball manager, or a politician, having successful negotiation skills is a critical part of being a leader. Building upon prior journal articles on negotiation strategy, the author presents the concept of the multiple equivalent simultaneous offer (MESO). The concept of a MESO is straightforward: as opposed to making a single offer, make multiple offers with several variables. Each offer alters the different variables, such that the end result of each offer is equivalent from the perspective of the party making the offer. Research has found several advantages to the use of MESOs. For example, using MESOs, an offer was more likely to be accepted, and the counterparty was more likely to be satisfied with the negotiated deal. Additional benefits have been documented as well, underscoring why a prepared radiology business leader should understand the theory and practice of MESO. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Simultaneous processing of information on multiple errors in visuomotor learning.

    Science.gov (United States)

    Kasuga, Shoko; Hirashima, Masaya; Nozaki, Daichi

    2013-01-01

    The proper association between planned and executed movements is crucial for motor learning because the discrepancies between them drive such learning. Our study explored how this association was determined when a single action caused the movements of multiple visual objects. Participants reached toward a target by moving a cursor, which represented the right hand's position. Once every five to six normal trials, we interleaved either of two kinds of visual perturbation trials: rotation of the cursor by a certain amount (±15°, ±30°, and ±45°) around the starting position (single-cursor condition) or rotation of two cursors by different angles (+15° and -45°, 0° and 30°, etc.) that were presented simultaneously (double-cursor condition). We evaluated the aftereffects of each condition in the subsequent trial. The error sensitivity (ratio of the aftereffect to the imposed visual rotation) in the single-cursor trials decayed with the amount of rotation, indicating that the motor learning system relied to a greater extent on smaller errors. In the double-cursor trials, we obtained a coefficient that represented the degree to which each of the visual rotations contributed to the aftereffects based on the assumption that the observed aftereffects were a result of the weighted summation of the influences of the imposed visual rotations. The decaying pattern according to the amount of rotation was maintained in the coefficient of each imposed visual rotation in the double-cursor trials, but the value was reduced to approximately 40% of the corresponding error sensitivity in the single-cursor trials. We also found a further reduction of the coefficients when three distinct cursors were presented (e.g., -15°, 15°, and 30°). These results indicated that the motor learning system utilized multiple sources of visual error information simultaneously to correct subsequent movement and that a certain averaging mechanism might be at work in the utilization process.

  3. Doses of Nearby Nature Simultaneously Associated with Multiple Health Benefits

    Directory of Open Access Journals (Sweden)

    Daniel T. C. Cox

    2017-02-01

    Full Text Available Exposure to nature provides a wide range of health benefits. A significant proportion of these are delivered close to home, because this offers an immediate and easily accessible opportunity for people to experience nature. However, there is limited information to guide recommendations on its management and appropriate use. We apply a nature dose-response framework to quantify the simultaneous association between exposure to nearby nature and multiple health benefits. We surveyed ca. 1000 respondents in Southern England, UK, to determine relationships between (a nature dose type, that is the frequency and duration (time spent in private green space and intensity (quantity of neighbourhood vegetation cover of nature exposure and (b health outcomes, including mental, physical and social health, physical behaviour and nature orientation. We then modelled dose-response relationships between dose type and self-reported depression. We demonstrate positive relationships between nature dose and mental and social health, increased physical activity and nature orientation. Dose-response analysis showed that lower levels of depression were associated with minimum thresholds of weekly nature dose. Nearby nature is associated with quantifiable health benefits, with potential for lowering the human and financial costs of ill health. Dose-response analysis has the potential to guide minimum and optimum recommendations on the management and use of nearby nature for preventative healthcare.

  4. UTILIZATION OF PHOSWICH DETECTORS FOR SIMULTANEOUS, MULTIPLE RADIATION DETECTION

    International Nuclear Information System (INIS)

    Miller, William H.; Manuel Diaz de Leon

    2003-01-01

    A phoswich radiation detector is comprised of a phosphor sandwich in which several different phosphors are viewed by a common photomultiplier. By selecting the appropriate phosphors, this system can be used to simultaneously measure multiple radiation types (alpha, beta, gamma and/or neutron) with a single detector. Differentiation between the signals from the different phosphors is accomplished using digital pulse shape discrimination techniques. This method has been shown to result in accurate discrimination with highly reliable and versatile digital systems. This system also requires minimal component count (i.e. only the detector and a computer for signal processing). A variety of detectors of this type have been built and tested including: (1) a triple phoswich system for alpha/beta/gamma swipe counting, (2) two well-type detectors for measuring low levels of low energy photons in the presence of a high energy background, (3) a large area detector for measuring beta contamination in the presence of a photon background, (4) another large area detector for measuring low energy photons from radioactive elements such as uranium in the presence of a photon background. An annular geometry, triple phoswich system optimized for measuring alpha/beta/gamma radiation in liquid waste processing streams is currently being designed

  5. Self-presentational persona: simultaneous management of multiple impressions.

    Science.gov (United States)

    Leary, Mark R; Allen, Ashley Batts

    2011-11-01

    Most research on self-presentation has examined how people convey images of themselves on only 1 or 2 dimensions at a time. In everyday interactions, however, people often manage their impressions on several image-relevant dimensions simultaneously. By examining people's self-presentations to several targets across multiple dimensions, these 2 studies offer new insights into the nature of self-presentation and provide a novel paradigm for studying impression management. Results showed that most people rely on a relatively small number of basic self-presentational personas in which they convey particular profiles of impressions as a set and that these personas reflect both normative influences to project images that are appropriate to a particular target and distinctive influences by which people put an idiosyncratic spin on these normative images. Furthermore, although people's self-presentational profiles correlate moderately with their self-views, they tailor their public images to specific targets. The degree to which participants' self-presentations were normative and distinctive, as well as the extent to which they reflected their own self-views, were moderated by individual differences in agreeableness, self-esteem, authenticity, and Machiavellianism.

  6. Simultaneous Helmert transformations among multiple frames considering all relevant measurements

    Science.gov (United States)

    Chang, Guobin; Lin, Peng; Bian, Hefang; Gao, Jingxiang

    2018-03-01

    Helmert or similarity models are widely employed to relate different coordinate frames. It is often encountered in practice to transform coordinates from more than one old frame into a new one. One may perform separate Helmert transformations for each old frame. However, although each transformation is locally optimal, this is not globally optimal. Transformations among three frames, namely one new and two old, are studied as an example. Simultaneous Helmert transformations among all frames are also studied. Least-squares estimation of the transformation parameters and the coordinates in the new frame of all stations involved is performed. A functional model for the transformations among multiple frames is developed. A realistic stochastic model is followed, in which not only non-common stations are taken into consideration, but also errors in all measurements are addressed. An algorithm of iterative linearizations and estimations is derived in detail. The proposed method is globally optimal, and, perhaps more importantly, it produces a unified network of the new frame providing coordinate estimates for all involved stations and the associated covariance matrix, with the latter being consistent with the true errors of the former. Simulations are conducted, and the results validate the superiority of the proposed combined method over separate approaches.

  7. UTILIZATION OF PHOSWICH DETECTORS FOR SIMULTANEOUS, MULTIPLE RADIATION DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    William H. Miller; Manuel Diaz de Leon

    2003-04-15

    A phoswich radiation detector is comprised of a phosphor sandwich in which several different phosphors are viewed by a common photomultiplier. By selecting the appropriate phosphors, this system can be used to simultaneously measure multiple radiation types (alpha, beta, gamma and/or neutron) with a single detector. Differentiation between the signals from the different phosphors is accomplished using digital pulse shape discrimination techniques. This method has been shown to result in accurate discrimination with highly reliable and versatile digital systems. This system also requires minimal component count (i.e. only the detector and a computer for signal processing). A variety of detectors of this type have been built and tested including: (1) a triple phoswich system for alpha/beta/gamma swipe counting, (2) two well-type detectors for measuring low levels of low energy photons in the presence of a high energy background, (3) a large area detector for measuring beta contamination in the presence of a photon background, (4) another large area detector for measuring low energy photons from radioactive elements such as uranium in the presence of a photon background. An annular geometry, triple phoswich system optimized for measuring alpha/beta/gamma radiation in liquid waste processing streams is currently being designed.

  8. SIMULTANEOUS DISC HERNIATION IN PATIENTS WITH MULTIPLE SCLEROSIS

    Directory of Open Access Journals (Sweden)

    Kalina V. Drenska

    2013-04-01

    Full Text Available Background: Multiple sclerosis (MS is a chronic autoimmune, inflammatory demyelinating disease of the central nervous system. Commonly, MS patients present with accompanying degenerative vertebral disc diseases. Simultaneous disc herniations situated in the cervical or lumbosacral spine can mimic the clinical symptoms of MS and worsen patients’ quality of life.Objective: to investigate the incidence rate and clinical impact of accompanying disc herniations in patients with MS.Material and methods: Our study covered 330 patients (220 females and 110 males, mean age 40.5±12.4 years with clinically definite MS, according to McDonald’s criteria. Comprehensive neurological examinations, EDSS (Expanded Disability Status Scale assessments, and MRI neuroimaging were carried out. Statistical data processing was performed by using the method of variation analysis.Results: Relapsing-remitting MS (RRMS was diagnosed in 280 patients while 50 patients presented with secondary progressive MS (SPMS. Disc herniation was found in 64 (19.4% of our patients. Cervical disc pathology was detected in 38 patients (11.5% of the cases and lumbosacral - in 26 (7.9% of the cases. EDSS scores ranged from 2.5 to 5.5. EDSS evaluation showed statistically significantly worse scores in MS patients with disc herniation comorbidity (p<0, 05.Conclusion: Our own data confirm the assumption that MS patients often present with accompanying degenerative disc pathology. We suggest that comorbidity of disc herniation and MS exert an additional unfavorable effect on patient’s disability and individual quality of life.

  9. A gas sensor array for the simultaneous detection of multiple VOCs.

    Science.gov (United States)

    Zhang, Yumin; Zhao, Jianhong; Du, Tengfei; Zhu, Zhongqi; Zhang, Jin; Liu, Qingju

    2017-05-16

    Air quality around the globe is declining and public health is seriously threatened by indoor air pollution. Typically, indoor air pollutants are composed of a series of volatile organic compounds (VOCs) that are generally harmful to the human body, especially VOCs with low molecular weights (less than 100 Da). Moreover, in some situations, more than one type of VOC is present; thus, a device that can detect one or more VOCs simultaneously would be most beneficial. Here, we synthesized a sensor array with 4 units to detect 4 VOCs: acetone (unit 1), benzene (unit 2), methanol (unit 3) and formaldehyde (unit 4) simultaneously. All units were simultaneously exposed to 2.5 ppm of all four VOCs. The sensitivity of unit 1 was 14.67 for acetone and less than 2.54 for the other VOCs. The sensitivities of units 2, 3 and 4 to benzene, methanol and formaldehyde were 2 18.64, 20.98 and 17.26, respectively, and less than 4.01 for the other VOCs. These results indicated that the sensor array exhibited good selectivity and could be used for the real-time monitoring of indoor air quality. Thus, this device will be useful in situations requiring the simultaneous detection of multiple VOCs.

  10. Multiple microprocessor based nuclear reactor power monitor

    International Nuclear Information System (INIS)

    Lewis, P.S.; Ethridge, C.D.

    1979-01-01

    The reactor power monitor is a portable multiple-microprocessor controlled data acquisition device being built for the International Atomic Energy Association. Its function is to measure and record the hourly integrated operating thermal power level of a nuclear reactor for the purpose of detecting unannounced plutonium production. The monitor consists of a 3 He proportional neutron detector, a write-only cassette tape drive and control electronics based on two INTEL 8748 microprocessors. The reactor power monitor operates from house power supplied by the plant operator, but has eight hours of battery backup to cover power interruptions. Both the hourly power levels and any line power interruptions are recorded on tape and in memory. Intermediate dumps from the memory to a data terminal or strip chart recorder can be performed without interrupting data collection

  11. A pulse coding and decoding strategy to perform Lamb wave inspections using simultaneously multiple actuators

    Science.gov (United States)

    De Marchi, Luca; Marzani, Alessandro; Moll, Jochen; Kudela, Paweł; Radzieński, Maciej; Ostachowicz, Wiesław

    2017-07-01

    The performance of Lamb wave based monitoring systems, both in terms of diagnosis time and data complexity, can be enhanced by increasing the number of transducers used to actuate simultaneously the guided waves in the inspected medium. However, in case of multiple simultaneously-operated actuators the interference among the excited wave modes within the acquired signals has to be considered for the further processing. To this aim, in this work a code division strategy based on the Warped Frequency Transform is presented. At first, the proposed procedure encodes actuation pulses using Gold sequences. Next, for each considered actuator the acquired signals are compensated from dispersion by cross correlating the warped version of the actuated and received signals. Compensated signals form the base for a final wavenumber imaging meant at emphasizing defects and or anomalies by removing incident wavefield and edge reflections. The proposed strategy is tested numerically, and validated through an experiment in which guided waves are actuated in a plate by four piezoelectric transducers operating simultaneously.

  12. Simultaneous presence of multiple Campylobacter species in dogs

    NARCIS (Netherlands)

    Koene, M.G.J.; Houwers, D.J.; Dijkstra, J.R.; Duim, B.; Wagenaar, J.A.

    2004-01-01

    The prevalence of coinfection of Campylobacter species in dogs was determined using four isolation methods. In 26% of the positive-testing stools, multiple Campylobacter species were identified. The use of multiple isolation methods as well as the time lapse between sampling and processing are

  13. Simultaneous Two-Way Clustering of Multiple Correspondence Analysis

    Science.gov (United States)

    Hwang, Heungsun; Dillon, William R.

    2010-01-01

    A 2-way clustering approach to multiple correspondence analysis is proposed to account for cluster-level heterogeneity of both respondents and variable categories in multivariate categorical data. Specifically, in the proposed method, multiple correspondence analysis is combined with k-means in a unified framework in which "k"-means is…

  14. Optimized simultaneous inversion of primary and multiple reflections; Inversion linearisee simultanee des reflexions primaires et des reflexions multiples

    Energy Technology Data Exchange (ETDEWEB)

    Pelle, L.

    2003-12-01

    The removal of multiple reflections remains a real problem in seismic imaging. Many preprocessing methods have been developed to attenuate multiples in seismic data but none of them is satisfactory in 3D. The objective of this thesis is to develop a new method to remove multiples, extensible in 3D. Contrary to the existing methods, our approach is not a preprocessing step: we directly include the multiple removal in the imaging process by means of a simultaneous inversion of primaries and multiples. We then propose to improve the standard linearized inversion so as to make it insensitive to the presence of multiples in the data. We exploit kinematics differences between primaries and multiples. We propose to pick in the data the kinematics of the multiples we want to remove. The wave field is decomposed into primaries and multiples. Primaries are modeled by the Ray+Born operator from perturbations of the logarithm of impedance, given the velocity field. Multiples are modeled by the Transport operator from an initial trace, given the picking. The inverse problem simultaneously fits primaries and multiples to the data. To solve this problem with two unknowns, we take advantage of the isometric nature of the Transport operator, which allows to drastically reduce the CPU time: this simultaneous inversion is this almost as fast as the standard linearized inversion. This gain of time opens the way to different applications to multiple removal and in particular, allows to foresee the straightforward 3D extension. (author)

  15. Noninvasive optical monitoring multiple physiological parameters response to cytokine storm

    Science.gov (United States)

    Li, Zebin; Li, Ting

    2018-02-01

    Cancer and other disease originated by immune or genetic problems have become a main cause of death. Gene/cell therapy is a highlighted potential method for the treatment of these diseases. However, during the treatment, it always causes cytokine storm, which probably trigger acute respiratory distress syndrome and multiple organ failure. Here we developed a point-of-care device for noninvasive monitoring cytokine storm induced multiple physiological parameters simultaneously. Oxy-hemoglobin, deoxy-hemoglobin, water concentration and deep-tissue/tumor temperature variations were simultaneously measured by extended near infrared spectroscopy. Detection algorithms of symptoms such as shock, edema, deep-tissue fever and tissue fibrosis were developed and included. Based on these measurements, modeling of patient tolerance and cytokine storm intensity were carried out. This custom device was tested on patients experiencing cytokine storm in intensive care unit. The preliminary data indicated the potential of our device in popular and milestone gene/cell therapy, especially, chimeric antigen receptor T-cell immunotherapy (CAR-T).

  16. A PDP model of the simultaneous perception of multiple objects

    Science.gov (United States)

    Henderson, Cynthia M.; McClelland, James L.

    2011-06-01

    Illusory conjunctions in normal and simultanagnosic subjects are two instances where the visual features of multiple objects are incorrectly 'bound' together. A connectionist model explores how multiple objects could be perceived correctly in normal subjects given sufficient time, but could give rise to illusory conjunctions with damage or time pressure. In this model, perception of two objects benefits from lateral connections between hidden layers modelling aspects of the ventral and dorsal visual pathways. As with simultanagnosia, simulations of dorsal lesions impair multi-object recognition. In contrast, a large ventral lesion has minimal effect on dorsal functioning, akin to dissociations between simple object manipulation (retained in visual form agnosia and semantic dementia) and object discrimination (impaired in these disorders) [Hodges, J.R., Bozeat, S., Lambon Ralph, M.A., Patterson, K., and Spatt, J. (2000), 'The Role of Conceptual Knowledge: Evidence from Semantic Dementia', Brain, 123, 1913-1925; Milner, A.D., and Goodale, M.A. (2006), The Visual Brain in Action (2nd ed.), New York: Oxford]. It is hoped that the functioning of this model might suggest potential processes underlying dorsal and ventral contributions to the correct perception of multiple objects.

  17. Multiple UAV Cooperation for Wildfire Monitoring

    Science.gov (United States)

    Lin, Zhongjie

    Wildfires have been a major factor in the development and management of the world's forest. An accurate assessment of wildfire status is imperative for fire management. This thesis is dedicated to the topic of utilizing multiple unmanned aerial vehicles (UAVs) to cooperatively monitor a large-scale wildfire. This is achieved through wildfire spreading situation estimation based on on-line measurements and wise cooperation strategy to ensure efficiency. First, based on the understanding of the physical characteristics of the wildfire propagation behavior, a wildfire model and a Kalman filter-based method are proposed to estimate the wildfire rate of spread and the fire front contour profile. With the enormous on-line measurements from on-board sensors of UAVs, the proposed method allows a wildfire monitoring mission to benefit from on-line information updating, increased flexibility, and accurate estimation. An independent wildfire simulator is utilized to verify the effectiveness of the proposed method. Second, based on the filter analysis, wildfire spreading situation and vehicle dynamics, the influence of different cooperation strategies of UAVs to the overall mission performance is studied. The multi-UAV cooperation problem is formulated in a distributed network. A consensus-based method is proposed to help address the problem. The optimal cooperation strategy of UAVs is obtained through mathematical analysis. The derived optimal cooperation strategy is then verified in an independent fire simulation environment to verify its effectiveness.

  18. Simultaneous ECG-gated PET imaging of multiple mice

    International Nuclear Information System (INIS)

    Seidel, Jurgen; Bernardo, Marcelino L.; Wong, Karen J.; Xu, Biying; Williams, Mark R.; Kuo, Frank; Jagoda, Elaine M.; Basuli, Falguni; Li, Changhui; Griffiths, Gary L.

    2014-01-01

    Introduction: We describe and illustrate a method for creating ECG-gated PET images of the heart for each of several mice imaged at the same time. The method is intended to increase “throughput” in PET research studies of cardiac dynamics or to obtain information derived from such studies, e.g. tracer concentration in end-diastolic left ventricular blood. Methods: An imaging bed with provisions for warming, anesthetic delivery, etc., was fabricated by 3D printing to allow simultaneous PET imaging of two side-by-side mice. After electrode attachment, tracer injection and placement of the animals in the scanner field of view, ECG signals from each animal were continuously analyzed and independent trigger markers generated whenever an R-wave was detected in each signal. PET image data were acquired in “list” mode and these trigger markers were inserted into this list along with the image data. Since each mouse is in a different spatial location in the FOV, sorting of these data using trigger markers first from one animal and then the other yields two independent and correctly formed ECG-gated image sequences that reflect the dynamical properties of the heart during an “average” cardiac cycle. Results: The described method yields two independent ECG-gated image sequences that exhibit the expected properties in each animal, e.g. variation of the ventricular cavity volumes from maximum to minimum and back during the cardiac cycle in the processed animal with little or no variation in these volumes during the cardiac cycle in the unprocessed animal. Conclusion: ECG-gated image sequences for each of several animals can be created from a single list mode data collection using the described method. In principle, this method can be extended to more than two mice (or other animals) and to other forms of physiological gating, e.g. respiratory gating, when several subjects are imaged at the same time

  19. Evidence for simultaneous syntactic processing of multiple words during reading.

    Directory of Open Access Journals (Sweden)

    Joshua Snell

    Full Text Available A hotly debated issue in reading research concerns the extent to which readers process parafoveal words, and how parafoveal information might influence foveal word recognition. We investigated syntactic word processing both in sentence reading and in reading isolated foveal words when these were flanked by parafoveal words. In Experiment 1 we found a syntactic parafoveal preview benefit in sentence reading, meaning that fixation durations on target words were decreased when there was a syntactically congruent preview word at the target location (n during the fixation on the pre-target (n-1. In Experiment 2 we used a flanker paradigm in which participants had to classify foveal target words as either noun or verb, when those targets were flanked by syntactically congruent or incongruent words (stimulus on-time 170 ms. Lower response times and error rates in the congruent condition suggested that higher-order (syntactic information can be integrated across foveal and parafoveal words. Although higher-order parafoveal-on-foveal effects have been elusive in sentence reading, results from our flanker paradigm show that the reading system can extract higher-order information from multiple words in a single glance. We propose a model of reading to account for the present findings.

  20. Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents.

    Science.gov (United States)

    Anderson, Christian E; Donnola, Shannon B; Jiang, Yun; Batesole, Joshua; Darrah, Rebecca; Drumm, Mitchell L; Brady-Kalnay, Susann M; Steinmetz, Nicole F; Yu, Xin; Griswold, Mark A; Flask, Chris A

    2017-08-16

    Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.

  1. Simultaneity, Sequentiality, and Speed: Organizational Messages about Multiple-Task Completion

    Science.gov (United States)

    Stephens, Keri K.; Cho, Jaehee K.; Ballard, Dawna I.

    2012-01-01

    Workplace norms for task completion increasingly value speed and the ability to accomplish multiple tasks at once. This study situates this popularized issue of multitasking within the context of chronemics scholarship by addressing related issues of simultaneity, sequentiality, and speed. Ultimately, we consider 2 multiple-task completion…

  2. DEP-On-Go for Simultaneous Sensing of Multiple Heavy Metals Pollutants in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Madhu Biyani

    2016-12-01

    Full Text Available We describe a simple and affordable “Disposable electrode printed (DEP-On-Go” sensing platform for the rapid on-site monitoring of trace heavy metal pollutants in environmental samples for early warning by developing a mobile electrochemical device composed of palm-sized potentiostat and disposable unmodified screen-printed electrode chips. We present the analytical performance of our device for the sensitive detection of major heavy metal ions, namely, mercury, cadmium, lead, arsenic, zinc, and copper with detection limits of 1.5, 2.6, 4.0, 5.0, 14.4, and, 15.5 μg·L−1, respectively. Importantly, the utility of this device is extended to detect multiple heavy metals simultaneously with well-defined voltammograms and similar sensitivity. Finally, “DEP-On-Go” was successfully applied to detect heavy metals in real environmental samples from groundwater, tap water, house dust, soil, and industry-processed rice and noodle foods. We evaluated the efficiency of this system with a linear correlation through inductively coupled plasma mass spectrometry, and the results suggested that this system can be reliable for on-site screening purposes. On-field applications using real samples of groundwater for drinking in the northern parts of India support the easy-to-detect, low-cost (<1 USD, rapid (within 5 min, and reliable detection limit (ppb levels performance of our device for the on-site detection and monitoring of multiple heavy metals in resource-limited settings.

  3. Using Simultaneous Prompting Procedure to Promote Recall of Multiplication Facts by Middle School Students with Cognitive Impairment

    Science.gov (United States)

    Rao, Shaila; Mallow, Lynette

    2009-01-01

    This study examined effectiveness of simultaneous prompting system in teaching students with cognitive impairment to automate recall of multiplication facts. A multiple probes design with multiple sets of math facts and replicated across multiple subjects was used to assess effectiveness of simultaneous prompting on recall of basic multiplication…

  4. Paper Skin Multisensory Platform for Simultaneous Environmental Monitoring

    KAUST Repository

    Nassar, Joanna M.

    2016-02-19

    Human skin and hair can simultaneously feel pressure, temperature, humidity, strain, and flow—great inspirations for applications such as artificial skins for burn and acid victims, robotics, and vehicular technology. Previous efforts in this direction use sophisticated materials or processes. Chemically functionalized, inkjet printed or vacuum-technology-processed papers albeit cheap have shown limited functionalities. Thus, performance and/or functionalities per cost have been limited. Here, a scalable “garage” fabrication approach is shown using off-the-shelf inexpensive household elements such as aluminum foil, scotch tapes, sticky-notes, napkins, and sponges to build “paper skin” with simultaneous real-time sensing capability of pressure, temperature, humidity, proximity, pH, and flow. Enabling the basic principles of porosity, adsorption, and dimensions of these materials, a fully functioning distributed sensor network platform is reported, which, for the first time, can sense the vitals of its carrier (body temperature, blood pressure, heart rate, and skin hydration) and the surrounding environment.

  5. Expanded beam deflection method for simultaneous measurement of displacement and vibrations of multiple microcantilevers

    International Nuclear Information System (INIS)

    Nieradka, K.; MaloziePc, G.; Kopiec, D.; Gotszalk, T.; Grabiec, P.; Janus, P.; Sierakowski, A.

    2011-01-01

    Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.

  6. Simultaneous control of multiple instruments at the Advanced Technology Solar Telescope

    Science.gov (United States)

    Johansson, Erik M.; Goodrich, Bret

    2012-09-01

    The Advanced Technology Solar Telescope (ATST) is a 4-meter solar observatory under construction at Haleakala, Hawaii. The simultaneous use of multiple instruments is one of the unique capabilities that makes the ATST a premier ground based solar observatory. Control of the instrument suite is accomplished by the Instrument Control System (ICS), a layer of software between the Observatory Control System (OCS) and the instruments. The ICS presents a single narrow interface to the OCS and provides a standard interface for the instruments to be controlled. It is built upon the ATST Common Services Framework (CSF), an infrastructure for the implementation of a distributed control system. The ICS responds to OCS commands and events, coordinating and distributing them to the various instruments while monitoring their progress and reporting the status back to the OCS. The ICS requires no specific knowledge about the instruments. All information about the instruments used in an experiment is passed by the OCS to the ICS, which extracts and forwards the parameters to the appropriate instrument controllers. The instruments participating in an experiment define the active instrument set. A subset of those instruments must complete their observing activities in order for the experiment to be considered complete and are referred to as the must-complete instrument set. In addition, instruments may participate in eavesdrop mode, outside of the control of the ICS. All instrument controllers use the same standard narrow interface, which allows new instruments to be added without having to modify the interface or any existing instrument controllers.

  7. Aptamer/quantum dot-based simultaneous electrochemical detection of multiple small molecules

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Haixia [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Jiang Bingying [School of Chemistry and Chemical Engineering, Chongqing University of Technology, Chongqing 400040 (China); Xiang Yun, E-mail: yunatswu@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Zhang Yuyong; Chai Yaqin [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Yuan Ruo, E-mail: yuanruo@swu.edu.cn [Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China)

    2011-03-04

    A novel strategy for 'signal on' and sensitive one-spot simultaneous detection of multiple small molecular analytes based on electrochemically encoded barcode quantum dot (QD) tags is described. The target analytes, adenosine triphosphate (ATP) and cocaine, respectively, are sandwiched between the corresponding set of surface-immobilized primary binding aptamers and the secondary binding aptamer/QD bioconjugates. The captured QDs yield distinct electrochemical signatures after acid dissolution, whose position and size reflect the identity and level, respectively, of the corresponding target analytes. Due to the inherent amplification feature of the QD labels and the 'signal on' detection scheme, as well as the sensitive monitoring of the metal ions released upon acid dissolution of the QD labels, low detection limits of 30 nM and 50 nM were obtained for ATP and cocaine, respectively, in our assays. Our multi-analyte sensing system also shows high specificity to target analytes and promising applicability to complex sample matrix, which makes the proposed assay protocol an attractive route for screening of small molecules in clinical diagnosis.

  8. A new parameter to simultaneously assess antioxidant activity for multiple phenolic compounds present in food products.

    Science.gov (United States)

    Yang, Hong; Xue, Xuejia; Li, Huan; Tay-Chan, Su Chin; Ong, Seng Poon; Tian, Edmund Feng

    2017-08-15

    In this work, we established a new methodology to simultaneously assess the relative reaction rates of multiple antioxidant compounds in one experimental set-up. This new methodology hypothesizes that the competition among antioxidant compounds towards limiting amount of free radical (in this article, DPPH) would reflect their relative reaction rates. In contrast with the conventional detection of DPPH decrease at 515nm on a spectrophotometer, depletion of antioxidant compounds treated by a series of DPPH concentrations was monitored instead using liquid chromatography coupled with quadrupole time-of-flight (LC-QTOF). A new parameter, namely relative antioxidant activity (RAA), has been proposed to rank these antioxidants according to their reaction rate constants. We have investigated the applicability of RAA using pre-mixed standard phenolic compounds, and also extended this application to two food products, i.e. red wine and green tea. It has been found that RAA correlates well with the reported k values. This new parameter, RAA, provides a new perspective in evaluating antioxidant compounds present in food and herbal matrices. It not only realistically reflects the antioxidant activity of compounds when co-existing with competitive constituents; and it could also quicken up the discovery process in the search for potent yet rare antioxidants from many herbs of food/medicinal origins. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Braun, J.; Soederlund, B.

    1960-11-01

    An instrument is described which measures α and β contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers α-pulses, the outer chambers deliver β-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available

  10. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J; Soederlund, B

    1960-11-15

    An instrument is described which measures {alpha} and {beta} contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers {alpha}-pulses, the outer chambers deliver {beta}-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available.

  11. Simultaneous nano-tracking of multiple motor proteins via spectral discrimination of quantum dots.

    Science.gov (United States)

    Kakizuka, Taishi; Ikezaki, Keigo; Kaneshiro, Junichi; Fujita, Hideaki; Watanabe, Tomonobu M; Ichimura, Taro

    2016-07-01

    Simultaneous nanometric tracking of multiple motor proteins was achieved by combining multicolor fluorescent labeling of target proteins and imaging spectroscopy, revealing dynamic behaviors of multiple motor proteins at the sub-diffraction-limit scale. Using quantum dot probes of distinct colors, we experimentally verified the localization precision to be a few nanometers at temporal resolution of 30 ms or faster. One-dimensional processive movement of two heads of a single myosin molecule and multiple myosin molecules was successfully traced. Furthermore, the system was modified for two-dimensional measurement and applied to tracking of multiple myosin molecules. Our approach is useful for investigating cooperative movement of proteins in supramolecular nanomachinery.

  12. Methods for monitoring multiple gene expression

    Energy Technology Data Exchange (ETDEWEB)

    Berka, Randy [Davis, CA; Bachkirova, Elena [Davis, CA; Rey, Michael [Davis, CA

    2012-05-01

    The present invention relates to methods for monitoring differential expression of a plurality of genes in a first filamentous fungal cell relative to expression of the same genes in one or more second filamentous fungal cells using microarrays containing Trichoderma reesei ESTs or SSH clones, or a combination thereof. The present invention also relates to computer readable media and substrates containing such array features for monitoring expression of a plurality of genes in filamentous fungal cells.

  13. Methods for monitoring multiple gene expression

    Energy Technology Data Exchange (ETDEWEB)

    Berka, Randy; Bachkirova, Elena; Rey, Michael

    2013-10-01

    The present invention relates to methods for monitoring differential expression of a plurality of genes in a first filamentous fungal cell relative to expression of the same genes in one or more second filamentous fungal cells using microarrays containing Trichoderma reesei ESTs or SSH clones, or a combination thereof. The present invention also relates to computer readable media and substrates containing such array features for monitoring expression of a plurality of genes in filamentous fungal cells.

  14. Simultaneous X-ray diffraction from multiple single crystals of macromolecules

    DEFF Research Database (Denmark)

    Paithankar, Karthik S.; Sørensen, Henning Osholm; Wright, Jonathan P.

    2011-01-01

    The potential in macromolecular crystallography for using multiple crystals to collect X-ray diffraction data simultaneously from assemblies of up to seven crystals is explored. The basic features of the algorithms used to extract data and their practical implementation are described. The procedure...

  15. Atom localization and center-of-mass wave-function determination via multiple simultaneous quadrature measurements

    International Nuclear Information System (INIS)

    Evers, Joerg; Qamar, Shahid; Zubairy, M. Suhail

    2007-01-01

    We discuss localization and center-of-mass wave-function measurement of a quantum particle using multiple simultaneous dispersive interactions of the particle with different standing-wave fields. In particular, we consider objects with an internal structure consisting of a single ground state and several excited states. The transitions between ground and the corresponding excited states are coupled to the light fields in the dispersive limit, thus giving rise to a phase shift of the light field during the interaction. We show that multiple simultaneous measurements allow both an increase in the measurement or localization precision in a single direction and the performance of multidimensional measurements or localization. Further, we show that multiple measurements may relax the experimental requirements for each individual measurement

  16. Busy boards: How does the simultaneous participation of directors in multiple companies affect the board’s activities?

    Directory of Open Access Journals (Sweden)

    Sandra Guerra

    2011-11-01

    Full Text Available We analyze the simultaneous participation of directors in multiple companies and its effects on boards’ roles and activities. By sitting in multiple boards, directors may face time scarcity and they may be too busy to adequately perform their tasks. Using survey questionnaires about board’s activities, which were directly sent to firms and their directors, this paper founds that busy boards are considered to be less active, less independent and less relevant to firms. Additionally, these boards are less committed to their responsibilities, such as hiring/firing the CEO and evaluating executives’ performance. They also do not monitor the firm’s risk properly. Our results present an insider perception of the board’s roles and activities, which can be useful for market regulators and policy-makers.

  17. Volcano Monitoring using Multiple Remote Data Sources

    Science.gov (United States)

    Reath, K. A.; Pritchard, M. E.

    2016-12-01

    Satellite-based remote sensing instruments can be used to determine quantitative values related to precursory activity that can act as a warning sign of an upcoming eruption. These warning signs are measured through examining anomalous activity in: (1) thermal flux, (2) gas/aerosol emission rates, (3) ground deformation, and (4) ground-based seismic readings. Patterns in each of these data sources are then analyzed to create classifications of different phases of precursory activity. These different phases of activity act as guidelines to monitor the progression of precursory activity leading to an eruption. Current monitoring methods rely on using high temporal resolution satellite imagery from instruments like the Advanced Very High Resolution Radiometer (AVHRR) and the Moderate Resolution Imaging Spectrometer (MODIS) sensors, for variations in thermal and aerosol emissions, and the Ozone Monitoring Instruments (OMI) and Ozone Mapping Profiler Suite (OMPS) instruments, for variations in gas emissions, to provide a valuable resource for near real-time monitoring of volcanic activity. However, the low spatial resolution of these data only enable events that produce a high thermal output or a large amount of gas/aerosol emissions to be detected. High spatial resolution instruments, like the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) sensor, have a small enough pixel size (90m2) that the subtle variations in both thermal flux and gas/aerosol emission rates in the pre-eruptive period can be detected. Including these data with the already established high temporal resolution data helps to identify and classify precursory activity patterns months before an eruption (Reath et al, 2016). By correlating these data with ground surface deformation data, determined from the Interferometric Synthetic Aperture Radar (InSAR) sensor, and seismic data, collected by the Incorporated Research Institution for Seismology (IRIS) data archive, subtle

  18. Tracking Multiple Statistics: Simultaneous Learning of Object Names and Categories in English and Mandarin Speakers.

    Science.gov (United States)

    Chen, Chi-Hsin; Gershkoff-Stowe, Lisa; Wu, Chih-Yi; Cheung, Hintat; Yu, Chen

    2017-08-01

    Two experiments were conducted to examine adult learners' ability to extract multiple statistics in simultaneously presented visual and auditory input. Experiment 1 used a cross-situational learning paradigm to test whether English speakers were able to use co-occurrences to learn word-to-object mappings and concurrently form object categories based on the commonalities across training stimuli. Experiment 2 replicated the first experiment and further examined whether speakers of Mandarin, a language in which final syllables of object names are more predictive of category membership than English, were able to learn words and form object categories when trained with the same type of structures. The results indicate that both groups of learners successfully extracted multiple levels of co-occurrence and used them to learn words and object categories simultaneously. However, marked individual differences in performance were also found, suggesting possible interference and competition in processing the two concurrent streams of regularities. Copyright © 2016 Cognitive Science Society, Inc.

  19. Simultaneous small-sample comparisons in longitudinal or multi-endpoint trials using multiple marginal models

    DEFF Research Database (Denmark)

    Pallmann, Philip; Ritz, Christian; Hothorn, Ludwig A

    2018-01-01

    , however only asymptotically. In this paper, we show how to make the approach also applicable to small-sample data problems. Specifically, we discuss the computation of adjusted P values and simultaneous confidence bounds for comparisons of randomised treatment groups as well as for levels......Simultaneous inference in longitudinal, repeated-measures, and multi-endpoint designs can be onerous, especially when trying to find a reasonable joint model from which the interesting effects and covariances are estimated. A novel statistical approach known as multiple marginal models greatly...... simplifies the modelling process: the core idea is to "marginalise" the problem and fit multiple small models to different portions of the data, and then estimate the overall covariance matrix in a subsequent, separate step. Using these estimates guarantees strong control of the family-wise error rate...

  20. Three-dimensional fluorescent microscopy via simultaneous illumination and detection at multiple planes.

    Science.gov (United States)

    Ma, Qian; Khademhosseinieh, Bahar; Huang, Eric; Qian, Haoliang; Bakowski, Malina A; Troemel, Emily R; Liu, Zhaowei

    2016-08-16

    The conventional optical microscope is an inherently two-dimensional (2D) imaging tool. The objective lens, eyepiece and image sensor are all designed to capture light emitted from a 2D 'object plane'. Existing technologies, such as confocal or light sheet fluorescence microscopy have to utilize mechanical scanning, a time-multiplexing process, to capture a 3D image. In this paper, we present a 3D optical microscopy method based upon simultaneously illuminating and detecting multiple focal planes. This is implemented by adding two diffractive optical elements to modify the illumination and detection optics. We demonstrate that the image quality of this technique is comparable to conventional light sheet fluorescent microscopy with the advantage of the simultaneous imaging of multiple axial planes and reduced number of scans required to image the whole sample volume.

  1. Simultaneous energy harvesting and information processing in wireless multiple relays with multiple antennas

    Science.gov (United States)

    Albaaj, Azhar; Makki, S. Vahab A.; Alabkhat, Qassem; Zahedi, Abdulhamid

    2017-07-01

    Wireless networks suffer from battery discharging specially in cooperative communications when multiple relays have an important role but they are energy constrained. To overcome this problem, energy harvesting from radio frequency signals is applied to charge the node battery. These intermediate nodes have the ability to harvest energy from the source signal and use the energy harvested to transmit information to the destination. In fact, the node tries to harvest energy and then transmit the data to destination. Division of energy harvesting and data transmission can be done in two algorithms: time-switching-based relaying protocol and power-splitting-based relaying protocol. These two algorithms also can be applied in delay-limited and delay-tolerant transmission systems. The previous works have assumed a single relay for energy harvesting, but in this article, the proposed method is concentrated on improving the outage probability and throughput by using multiple antennas in each relay node instead of using single antenna. According to our simulation results, when using multi-antenna relays, ability of energy harvesting is increased and thus system performance will be improved to great extent. Maximum ratio combining scheme has been used when the destination chooses the best signal of relays and antennas satisfying the required signal-to-noise ratio.

  2. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device.

    Science.gov (United States)

    Cordeiro, C A; de Vries, M G; Ngabi, W; Oomen, P E; Cremers, T I F H; Westerink, B H C

    2015-05-15

    Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will provide better understanding of brain energy metabolism and its role in neuropathologies such as diabetes, ischemia, and epilepsy. We have developed and characterized an implantable multiplex microbiosensor device (MBD) for simultaneous and continuous in vivo monitoring of glucose, lactate, and pyruvate. First, we developed and characterized amperometric microbiosensors for monitoring lactate and pyruvate. In vitro evaluation allowed us to choose the most suitable biosensors for incorporation into the MBD, along with glucose and background biosensors. Fully assembled MBDs were characterized in vitro. The calculated performance parameters (LOD, LR, LRS, IMAX and appKM) showed that the multiplex MBD was highly selective and sensitive (LRS≥100 nA/mM) for each analyte and within an adequate range for in vivo application. Finally, MBDs were implanted in the mPFC of anesthetized adult male Wistar rats for in vivo evaluation. Following an equilibration period, baseline brain levels of glucose (1.3±0.2 mM), lactate (1.5±0.4 mM) and pyruvate (0.3±0.1 mM) were established. Subsequently, the MBDs recorded the responses of the animals when submitted to hyperglycemic (40% glucose i.v.) and hypoglycemic (5 U/kg insulin i.v.) challenges. Afterwards, MBDs were recalibrated to convert electrochemical readings into accurate substrate concentrations and to assess biofouling. The presented MBD can monitor simultaneously multiple biomarkers in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A Convenient Cas9-based Conditional Knockout Strategy for Simultaneously Targeting Multiple Genes in Mouse.

    Science.gov (United States)

    Chen, Jiang; Du, Yinan; He, Xueyan; Huang, Xingxu; Shi, Yun S

    2017-03-31

    The most powerful way to probe protein function is to characterize the consequence of its deletion. Compared to conventional gene knockout (KO), conditional knockout (cKO) provides an advanced gene targeting strategy with which gene deletion can be performed in a spatially and temporally restricted manner. However, for most species that are amphiploid, the widely used Cre-flox conditional KO (cKO) system would need targeting loci in both alleles to be loxP flanked, which in practice, requires time and labor consuming breeding. This is considerably significant when one is dealing with multiple genes. CRISPR/Cas9 genome modulation system is advantaged in its capability in targeting multiple sites simultaneously. Here we propose a strategy that could achieve conditional KO of multiple genes in mouse with Cre recombinase dependent Cas9 expression. By transgenic construction of loxP-stop-loxP (LSL) controlled Cas9 (LSL-Cas9) together with sgRNAs targeting EGFP, we showed that the fluorescence molecule could be eliminated in a Cre-dependent manner. We further verified the efficacy of this novel strategy to target multiple sites by deleting c-Maf and MafB simultaneously in macrophages specifically. Compared to the traditional Cre-flox cKO strategy, this sgRNAs-LSL-Cas9 cKO system is simpler and faster, and would make conditional manipulation of multiple genes feasible.

  4. Forestland owners’ willingness to consider multiple ways of supplying biomass simultaneously: Implications for biofuel incentive policies

    International Nuclear Information System (INIS)

    Wolde, Bernabas; Lal, Pankaj; Burli, Pralhad

    2017-01-01

    Because socioeconomic based approaches account for relevant limiting and motivating factors, they provide a more realistic measurement of forestland owners’ willingness to supply biomass for bioenergy production- information useful to policy makers in setting production targets and in designing relevant incentive programs. Although forestland owners can supply biomass using different means, including supplying biomass from existing stands and changing land use to establish feedstock plantation, among others, previous studies mostly focus only on a given way of supplying biomass at a time. This produces incomplete information that adversely affects its use. By presenting survey takers in Virginia and Texas three different ways of supplying biomass at the same time, we determine forestland owners’ willingness to consider multiple ways of supplying biomass simultaneously and identify the factors that predict such behavior, assess overlap in forestland owners across the different ways of supplying biomass, and assess if and how respondents’ forest management plans and sustainability concerns correspond with their supply decision. Our results show a higher and more articulated rate of willingness to supply biomass than reported in previous studies. The results also suggest that opportunities exist for synergizing programs that incentivize disparate ways of supplying biomass. - Highlights: • Forestland owners are more willing to supply biomass than previous estimated. • Forestland owners will consider multiple ways of supplying biomass simultaneously. • Socioeconomics, sustainability concerns, and management plans predict this behavior. • Incentive programs can target multiple means of supplying biomass simultaneously. • Considerable mismatches exist between the suppliers’ preferences and existing policies.

  5. Dual-Functional Ultrafiltration Membrane for Simultaneous Removal of Multiple Pollutants with High Performance.

    Science.gov (United States)

    Pan, Shunlong; Li, Jiansheng; Noonan, Owen; Fang, Xiaofeng; Wan, Gaojie; Yu, Chengzhong; Wang, Lianjun

    2017-05-02

    Simultaneous removal of multiple pollutants from aqueous solution with less energy consumption is crucial in water purification. Here, a novel concept of dual-functional ultrafiltration (DFUF) membrane is demonstrated by entrapment of nanostructured adsorbents into the finger-like pores of ultrafiltration (UF) membrane rather than in the membrane matrix in previous reports of blend membranes, resulting in an exceptionally high active content and simultaneous removal of multiple pollutants from water due to the dual functions of rejection and adsorption. As a demonstration, hollow porous Zr(OH) x nanospheres (HPZNs) were immobilized in poly(ether sulfone) (PES) UF membranes through polydopamine coating with a high content of 68.9 wt %. The decontamination capacity of DFUF membranes toward multiple model pollutants (colloidal gold, polyethylene glycol (PEG), Pb(II)) was evaluated against a blend membrane. Compared to the blend membrane, the DFUF membranes showed 2.1-fold increase in the effective treatment volume for the treatment of Pb(II) contaminated water from 100 ppb to below 10 ppb (WHO drinking water standard). Simultaneously, the DFUF membranes effectively removed the colloidal gold and PEG below instrument detection limit, however the blend membrane only achieved 97.6% and 96.8% rejection for colloidal gold and PEG, respectively. Moreover, the DFUF membranes showed negligible leakage of nanoadsorbents during testing; and the membrane can be easily regenerated and reused. This study sheds new light on the design of high performance multifunction membranes for drinking water purification.

  6. Upper GI examinations in older premature infants with persistent apnea: Correlation with simultaneous cardiorespiratory monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Itani, Y.; Niitsu, N.; Oono, T.; Fujioka, M.; Nishimura, G.

    1988-09-01

    Upper gastrointestinal examinations with simultaneous cardiorespiratory monitoring were performed in 39 older premature infants with persistent apnea. Swallowing incoordination was documented to be causatively related to persistent apnea in such infants, especially with feeding. Direct relationship between apnea and gastroesophageal reflux was not documented in this study.

  7. Simultaneous Multiple Preoperative Localizations of Small Pulmonary Lesions Using a Short Hook Wire and Suture System

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Matsui, Yusuke; Sugimoto, Seiichiro; Toyooka, Shinichi; Oto, Takahiro; Miyoshi, Shinichiro; Kanazawa, Susumu

    2015-01-01

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful; in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time

  8. Simultaneous Multiple Preoperative Localizations of Small Pulmonary Lesions Using a Short Hook Wire and Suture System

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp; Fujiwara, Hiroyasu, E-mail: hirofujiwar@gmail.com; Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp [Okayama University Medical School, Department of Radiology (Japan); Sugimoto, Seiichiro, E-mail: sei1675sugi@yahoo.co.jp; Toyooka, Shinichi, E-mail: shintoyooka@gmail.com; Oto, Takahiro, E-mail: yellowpeachoto@hotmail.com; Miyoshi, Shinichiro, E-mail: smiyoshi@md.okayama-u.ac.jp [Okayama University Medical School, Department of General Thoracic Surgery (Japan); Kanazawa, Susumu, E-mail: susumu@cc.okayama-u.ac.jp [Okayama University Medical School, Department of Radiology (Japan)

    2015-08-15

    PurposeThe aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated.ResultsIn 35 procedures including 74 lesions, multiple hook wire placements were technically successful; in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051).ConclusionsSimultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.

  9. Simultaneous sequential monitoring of efficacy and safety led to masking of effects.

    Science.gov (United States)

    van Eekelen, Rik; de Hoop, Esther; van der Tweel, Ingeborg

    2016-08-01

    Usually, sequential designs for clinical trials are applied on the primary (=efficacy) outcome. In practice, other outcomes (e.g., safety) will also be monitored and influence the decision whether to stop a trial early. Implications of simultaneous monitoring on trial decision making are yet unclear. This study examines what happens to the type I error, power, and required sample sizes when one efficacy outcome and one correlated safety outcome are monitored simultaneously using sequential designs. We conducted a simulation study in the framework of a two-arm parallel clinical trial. Interim analyses on two outcomes were performed independently and simultaneously on the same data sets using four sequential monitoring designs, including O'Brien-Fleming and Triangular Test boundaries. Simulations differed in values for correlations and true effect sizes. When an effect was present in both outcomes, competition was introduced, which decreased power (e.g., from 80% to 60%). Futility boundaries for the efficacy outcome reduced overall type I errors as well as power for the safety outcome. Monitoring two correlated outcomes, given that both are essential for early trial termination, leads to masking of true effects. Careful consideration of scenarios must be taken into account when designing sequential trials. Simulation results can help guide trial design. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Simultaneous chromatic dispersion, polarization-mode-dispersion and OSNR monitoring at 40Gbit/s.

    Science.gov (United States)

    Baker-Meflah, Lamia; Thomsen, Benn; Mitchell, John; Bayvel, Polina

    2008-09-29

    A novel method for independent and simultaneous monitoring of chromatic dispersion (CD), first-order PMD and OSNR in 40Gbit/s systems is proposed and demonstrated. This is performed using in-band tone monitoring of 5GHz, optically down-converted to a low intermediate-frequency (IF) of 10kHz. The measurement provides a large monitoring range with good accuracies for CD (4742+/-100ps/nm), differential group delay (DGD) (200+/-4ps) and OSNR (23+/-1dB), independently of the bit-rate. In addition, the use of electro-absorption modulators (EAM) for the simultaneous down-conversion of all channels and the use of low-speed detectors makes it cost effective for multi-channel operation.

  11. Development of a multiple immunoaffinity column for simultaneous determination of multiple mycotoxins in feeds using UPLC-MS/MS.

    Science.gov (United States)

    Hu, Xiaofeng; Hu, Rui; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Wang, Min

    2016-09-01

    A sensitive and specific immunoaffinity column to clean up and isolate multiple mycotoxins was developed along with a rapid one-step sample preparation procedure for ultra-performance liquid chromatography-tandem mass spectrometry analysis. Monoclonal antibodies against aflatoxin B1, aflatoxin B2, aflatoxin G1, aflatoxin G2, zearalenone, ochratoxin A, sterigmatocystin, and T-2 toxin were coupled to microbeads for mycotoxin purification. We optimized a homogenization and extraction procedure as well as column loading and elution conditions to maximize recoveries from complex feed matrices. This method allowed rapid, simple, and simultaneous determination of mycotoxins in feeds with a single chromatographic run. Detection limits for these toxins ranged from 0.006 to 0.12 ng mL(-1), and quantitation limits ranged from 0.06 to 0.75 ng mL(-1). Concentration curves were linear from 0.12 to 40 μg kg(-1) with correlation coefficients of R (2) > 0.99. Intra-assay and inter-assay comparisons indicated excellent repeatability and reproducibility of the multiple immunoaffinity columns. As a proof of principle, 80 feed samples were tested and several contained multiple mycotoxins. This method is sensitive, rapid, and durable enough for multiple mycotoxin determinations that fulfill European Union and Chinese testing criteria.

  12. Age-related differences in multiple task monitoring.

    Science.gov (United States)

    Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo

    2014-01-01

    Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age.

  13. Age-related differences in multiple task monitoring.

    Directory of Open Access Journals (Sweden)

    Ivo Todorov

    Full Text Available Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age.

  14. Age-Related Differences in Multiple Task Monitoring

    OpenAIRE

    Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo

    2014-01-01

    Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men excee...

  15. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  16. Selective pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of internal anal sphincter and bladder innervation.

    Science.gov (United States)

    Kneist, W; Kauff, D W; Koch, K P; Schmidtmann, I; Heimann, A; Hoffmann, K P; Lang, H

    2011-01-01

    Pelvic autonomic nerve preservation avoids postoperative functional disturbances. The aim of this feasibility study was to develop a neuromonitoring system with simultaneous intraoperative verification of internal anal sphincter (IAS) activity and intravesical pressure. 14 pigs underwent low anterior rectal resection. During intermittent bipolar electric stimulation of the inferior hypogastric plexus (IHP) and the pelvic splanchnic nerves (PSN), electromyographic signals of the IAS and manometry of the urinary bladder were observed simultaneously. Stimulation of IHP and PSN as well as simultaneous intraoperative monitoring could be realized with an adapted neuromonitoring device. Neurostimulation resulted in either bladder or IAS activation or concerted activation of both. Intravesical pressure increase as well as amplitude increase of the IAS neuromonitoring signal did not differ significantly between stimulation of IHP and PSN [6.0 cm H(2)O (interquartile range [IQR] 3.5-9.0) vs. 6.0 cm H(2)O (IQR 3.0-10.0) and 12.1 μV (IQR 3.0-36.7) vs. 40.1 μV (IQR 9.0-64.3)] (p > 0.05). Pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of IAS and bladder innervation is feasible. The method may enable neuromonitoring with increasing selectivity for pelvic autonomic nerve preservation. Copyright © 2011 S. Karger AG, Basel.

  17. Simultaneous or Early Sequential Rupture of Multiple Intracranial Aneurysms: A Rare and Insufficiently Understood Entity.

    Science.gov (United States)

    Hou, Kun; Zhao, Jinchuan; Zhang, Yang; Zhu, Xiaobo; Zhao, Yan; Li, Guichen

    2016-05-01

    Simultaneous or early sequential rupture of multiple intracranial aneurysms (MIAs) is encountered rarely, with no more than 10 cases having been reported. As a result of its rarity, there are a lot of questions concerning this entity need to be answered. A 67-year-old woman was admitted to the First Hospital of Jilin University (Eastern Division) from a local hospital after a sudden onset of severe headache, nausea, and vomiting. Head computed tomography (CT) at the local hospital revealed diffuse subarachnoid hemorrhage (SAH) that was concentrated predominately in the suprasellar cistern and interhemispheric fissure. During her transfer to our hospital, she experienced another episode of sudden headache. CT on admission to our hospital revealed that the SAH was increased with 2 isolated hematomas both in the interhemispheric fissure and the left paramedian frontal lobe. Further CT angiography and intraoperative findings were in favor of early sequential rupture of 2 intracranial aneurysms. To further elucidate the characteristics, mechanism, management, and prognosis of this specific entity, we conducted a comprehensive review of the literature. The mechanism of simultaneous or early sequential rupture of MIAs is still obscure. Transient elevation of blood pressure might play a role in the process, and preventing the sudden elevation of blood pressure might be beneficial for patients with aneurysmal SAH and MIAs. The management of simultaneously or early sequentially ruptured aneurysms is more complex for its difficulty in responsible aneurysm determination, urgency in treatment, toughness in intraoperative manipulation and poorness in prognosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Simultaneous fluorescent detection of multiple metal ions based on the DNAzymes and graphene oxide.

    Science.gov (United States)

    Yun, Wen; Wu, Hong; Liu, Xingyan; Fu, Min; Jiang, Jiaolai; Du, Yunfeng; Yang, Lizhu; Huang, Yu

    2017-09-15

    A novel fluorescent detection strategy for simultaneous detection of Cu 2+ , Pb 2+ and Mg 2+ based on DNAzyme branched junction structure with three kinds of DNAzymes and graphene oxide (GO) was presented. Three fluorophores labeled DNA sequences consisted with enzyme-strand (E-DNA) and substrate strand (S-DNA) were annealed to form DNAzyme branched junction structure. In the presence of target metal ion, the DNAzyme was activated to cleave the fluorophore labeled S-DNA. The S-DNA fragments were released and adsorbed onto GO surface to quench the fluorescent signal. The detection limit was calculated to be 1 nM for Cu 2+ , 200 nM for Mg 2+ , and 0.3 nM for Pb 2+ , respectively. This strategy was successfully used for simultaneous detection of Cu 2+ , Mg 2+ and Pb 2+ in human serum. Moreover, it had potential application for simultaneous detection of multiple metal ions in environmental and biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. SATCHMO-JS: a webserver for simultaneous protein multiple sequence alignment and phylogenetic tree construction.

    Science.gov (United States)

    Hagopian, Raffi; Davidson, John R; Datta, Ruchira S; Samad, Bushra; Jarvis, Glen R; Sjölander, Kimmen

    2010-07-01

    We present the jump-start simultaneous alignment and tree construction using hidden Markov models (SATCHMO-JS) web server for simultaneous estimation of protein multiple sequence alignments (MSAs) and phylogenetic trees. The server takes as input a set of sequences in FASTA format, and outputs a phylogenetic tree and MSA; these can be viewed online or downloaded from the website. SATCHMO-JS is an extension of the SATCHMO algorithm, and employs a divide-and-conquer strategy to jump-start SATCHMO at a higher point in the phylogenetic tree, reducing the computational complexity of the progressive all-versus-all HMM-HMM scoring and alignment. Results on a benchmark dataset of 983 structurally aligned pairs from the PREFAB benchmark dataset show that SATCHMO-JS provides a statistically significant improvement in alignment accuracy over MUSCLE, Multiple Alignment using Fast Fourier Transform (MAFFT), ClustalW and the original SATCHMO algorithm. The SATCHMO-JS webserver is available at http://phylogenomics.berkeley.edu/satchmo-js. The datasets used in these experiments are available for download at http://phylogenomics.berkeley.edu/satchmo-js/supplementary/.

  20. Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom

    Science.gov (United States)

    Hwang, Han-Jeong; Hahne, Janne Mathias; Müller, Klaus-Robert

    2014-10-01

    Objective. Recent studies have shown the possibility of simultaneous and proportional control of electrically powered upper-limb prostheses, but there has been little investigation on optimal channel selection. The objective of this study is to find a robust channel selection method and the channel subsets most suitable for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom (DoFs). Approach. Ten able-bodied subjects and one person with congenital upper-limb deficiency took part in this study, and performed wrist movements with various combinations of two DoFs (flexion/extension and radial/ulnar deviation). During the experiment, high density electromyographic (EMG) signals and the actual wrist angles were recorded with an 8 × 24 electrode array and a motion tracking system, respectively. The wrist angles were estimated from EMG features with ridge regression using the subsets of channels chosen by three different channel selection methods: (1) least absolute shrinkage and selection operator (LASSO), (2) sequential feature selection (SFS), and (3) uniform selection (UNI). Main results. SFS generally showed higher estimation accuracy than LASSO and UNI, but LASSO always outperformed SFS in terms of robustness, such as noise addition, channel shift and training data reduction. It was also confirmed that about 95% of the original performance obtained using all channels can be retained with only 12 bipolar channels individually selected by LASSO and SFS. Significance. From the analysis results, it can be concluded that LASSO is a promising channel selection method for accurate simultaneous and proportional prosthesis control. We expect that our results will provide a useful guideline to select optimal channel subsets when developing clinical myoelectric prosthesis control systems based on continuous movements with multiple DoFs.

  1. Assessing Neurocognition via Gamified Experimental Logic: A novel approach to simultaneous acquisition of multiple ERPs

    Directory of Open Access Journals (Sweden)

    Ajay Kumar eNair

    2016-01-01

    Full Text Available The present study describes the development of a neurocognitive paradigm: ‘Assessing Neurocognition via Gamified Experimental Logic’ (ANGEL, for performing the parametric evaluation of multiple neurocognitive functions simultaneously. ANGEL employs an audiovisual sensory motor design for the acquisition of multiple event related potentials (ERPs - the C1, P50, MMN, N1, N170, P2, N2pc, LRP, P300 and ERN. The ANGEL paradigm allows assessment of ten neurocognitive variables over the course of three ‘game’ levels of increasing complexity ranging from simple passive observation to complex discrimination and response in the presence of multiple distractors. The paradigm allows assessment of several levels of rapid decision making: speeded up response vs response-inhibition; responses to easy vs difficult tasks; responses based on gestalt perception of clear vs ambiguous stimuli; and finally, responses with set shifting during challenging tasks. The paradigm has been tested using 18 healthy participants from both sexes and the possibilities of varied data analyses have been presented in this paper. The ANGEL approach provides an ecologically valid assessment (as compared to existing tools that quickly yields a very rich dataset and helps to assess multiple ERPs that can be studied extensively to assess cognitive functions in health and disease conditions.

  2. Assessing Neurocognition via Gamified Experimental Logic: A Novel Approach to Simultaneous Acquisition of Multiple ERPs.

    Science.gov (United States)

    Nair, Ajay K; Sasidharan, Arun; John, John P; Mehrotra, Seema; Kutty, Bindu M

    2016-01-01

    The present study describes the development of a neurocognitive paradigm: "Assessing Neurocognition via Gamified Experimental Logic" (ANGEL), for performing the parametric evaluation of multiple neurocognitive functions simultaneously. ANGEL employs an audiovisual sensory motor design for the acquisition of multiple event related potentials (ERPs)-the C1, P50, MMN, N1, N170, P2, N2pc, LRP, P300, and ERN. The ANGEL paradigm allows assessment of 10 neurocognitive variables over the course of three "game" levels of increasing complexity ranging from simple passive observation to complex discrimination and response in the presence of multiple distractors. The paradigm allows assessment of several levels of rapid decision making: speeded up response vs. response-inhibition; responses to easy vs. difficult tasks; responses based on gestalt perception of clear vs. ambiguous stimuli; and finally, responses with set shifting during challenging tasks. The paradigm has been tested using 18 healthy participants from both sexes and the possibilities of varied data analyses have been presented in this paper. The ANGEL approach provides an ecologically valid assessment (as compared to existing tools) that quickly yields a very rich dataset and helps to assess multiple ERPs that can be studied extensively to assess cognitive functions in health and disease conditions.

  3. Simultaneous determination of free and total glycerol in biodiesel by capillary electrophoresis using multiple short-end injection.

    Science.gov (United States)

    Spudeit, Daniel Alfonso; Piovezan, Marcel; Dolzan, Maressa D; Vistuba, Jacqueline Pereira; Azevedo, Mônia Stremel; Vitali, Luciano; Leal Oliveira, Marcone Augusto; Oliveira Costa, Ana Carolina; Micke, Gustavo Amadeu

    2013-12-01

    A rapid method for the simultaneous determination of free glycerol (FG) and total glycerol (TG) in biodiesel by CE using a short-end multiple injection (SE/MI) configuration system is described. The sample preparation for FG involves the extraction of glycerol with water and for TG a saponification reaction is carried out followed by extraction as in the case of FG. The glycerol extracted in both cases is submitted to periodate oxidation and the iodate ions formed are measured on a CE-SE/MI system. The relevance of this study lies in the fact that no analytical procedure has been previously reported for the determination of TG (or of FG and TG simultaneously) by CE. The optimum conditions for the saponification/extraction process were 1.25% KOH and 25°C, with a time of only 5 min, and biodiesel mass in the range of 50.0-200.0 mg can be used. Multiple injections were performed hydrodynamically with negative pressure as follows: 50 mbar/3s (FG sample); 50 mbar/6s (electrolyte spacer); 50 mbar/3s (TG sample). The linear range obtained was 1.55-46.5 mg/L with R(2) > 0.99. The LOD and LOQ were 0.16 mg/L and 0.47 mg/L, respectively for TG. The method provides acceptable throughput for application in quality control and monitoring biodiesel synthesis process. In addition, it offers simple sample preparation (saponification process), it can be applied to a variety biodiesel samples (soybean, castor, and waste cooking oils) and it can be used for the determination of two key parameters related to the biodiesel quality with a fast separation (less than 30 s) using an optimized CE-SE/MI system. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Simultaneous acoustic and dielectric real time curing monitoring of epoxy systems

    Science.gov (United States)

    Gkikas, G.; Saganas, Ch.; Grammatikos, S. A.; Aggelis, D. G.; Paipetis, A. S.

    2012-04-01

    The attainment of structural integrity of the reinforcing matrix in composite materials is of primary importance for the final properties of the composite structure. The detailed monitoring of the curing process on the other hand is paramount (i) in defining the optimal conditions for the impregnation of the reinforcement by the matrix (ii) in limiting the effects of the exotherm produced by the polymerization reaction which create unwanted thermal stresses and (iii) in securing optimal behavior in matrix controlled properties, such as off axis or shear properties and in general the durability of the composite. Dielectric curing monitoring is a well known technique for distinguishing between the different stages of the polymerization of a typical epoxy system. The technique successfully predicts the gelation and the vitrification of the epoxy and has been extended for the monitoring of prepregs. Recent work has shown that distinct changes in the properties of the propagated sound in the epoxy which undergoes polymerization is as well directly related to the gelation and vitrification of the resin, as well as to the attainment of the final properties of the resin system. In this work, a typical epoxy is simultaneously monitored using acoustic and dielectric methods. The system is isothermally cured in an oven to avoid effects from the polymerization exotherm. Typical broadband sensors are employed for the acoustic monitoring, while flat interdigital sensors are employed for the dielectric scans. All stages of the polymerization process were successfully monitored and the validity of both methods was cross checked and verified.

  5. Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.

    Science.gov (United States)

    Blue, Steven W; Winchell, Andrea J; Kaucher, Amy V; Lieberman, Rachel A; Gilles, Christopher T; Pyra, Maria N; Heffron, Renee; Hou, Xuanlin; Coombs, Robert W; Nanda, Kavita; Davis, Nicole L; Kourtis, Athena P; Herbeck, Joshua T; Baeten, Jared M; Lingappa, Jairam R; Erikson, David W

    2018-04-01

    The objective was to develop a method to simultaneously quantify five commonly used hormonal contraceptives (HCs) and two endogenous sex steroids by liquid chromatography-tandem triple quadrupole mass spectrometry (LC-MS/MS) and apply this method to human serum samples. We developed a method to simultaneously analyze ethinyl estradiol (EE2), etonogestrel (ENG), levonorgestrel (LNG), medroxyprogesterone acetate (MPA) and norethisterone (NET), along with estradiol (E2) and progesterone (P4), in human serum for a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. We analyzed serum collected from women self-reporting use of oral contraceptives, contraceptive implants or injectable contraceptives (n=14) and normally cycling women using no HC (n=15) as well as pooled samples from women administered various HCs (ENG, n=6; LNG, n=14; MPA, n=7; NET, n=5). Limits of quantitation were 0.010ng/mL for E2, EE2 and P4; 0.020ng/mL for ENG, LNG and MPA; and 0.040ng/mL for NET. Precisions for all assays, as indicated by coefficient of variation, were less than or equal to 12.1%. Accuracies for all assays were in the range of 95%-108%. Endogenous hormone values obtained from analysis of human serum samples are in agreement with levels previously reported in the literature for normally cycling women as well as for women taking the appropriate HC. We have developed a robust, accurate and sensitive method for simultaneously analyzing commonly used contraceptive steroids and endogenous sex steroids in human serum. This analytical method can be used for quantitating contraceptive steroid levels in women for monitoring systemic exposure to determine drug interactions, nonadherence, misreporting and proper dosing. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Mobile CARS - IRS Instrument for Simultaneous Spectroscopic Measurement of Multiple Properties in Gaseous Flows

    Science.gov (United States)

    Bivolaru, Daniel; Lee, Joseph W.; Jones, Stephen B.; Tedder, Sarah A.; Danehy, Paul M.; Weikl, M. C.; Magnotti, G.; Cutler, Andrew D.

    2007-01-01

    This paper describes a measurement system based on the dual-pump coherent anti-Stokes Raman spectroscopy (CARS) and interferometric Rayleigh scattering (IRS) methods. The IRS measurement is performed simultaneously with the CARS measurement using a common green laser beam as a narrow-band light source. The mobile CARS-IRS instrument is designed for the use both in laboratories as well as in ground-based combustion test facilities. Furthermore, it is designed to be easily transported between laboratory and test facility. It performs single-point spatially and temporally resolved simultaneous measurements of temperature, species mole fraction of N2, O2, and H2, and two-components of velocity. A mobile laser system can be placed inside or outside the test facility, while a beam receiving and monitoring system is placed near the measurement location. Measurements in a laboratory small-scale Mach 1.6 H2-air combustion-heated supersonic jet were performed to test the capability of the system. Final setup and pretests of a larger scale reacting jet are ongoing at NASA Langley Research Center s Direct Connect Supersonic Combustor Test Facility (DCSCTF).

  7. Simultaneous Multiple MS Binding Assays Addressing D1 and D2 Dopamine Receptors.

    Science.gov (United States)

    Schuller, Marion; Höfner, Georg; Wanner, Klaus T

    2017-10-09

    MS Binding Assays are a label-free alternative to radioligand binding assays. They provide basically the same capabilities as the latter, but use a non-labeled reporter ligand instead of a radioligand. In contrast to radioligand binding assays, MS Binding Assays offer-owing to the selectivity of mass spectrometric detection-the opportunity to monitor the binding of different reporter ligands at different targets simultaneously. The present study shows a proof of concept for this strategy as exemplified for MS Binding Assays selectively addressing D 1 and D 2 dopamine receptors in a single binding experiment. A highly sensitive, rapid and robust LC-ESI-MS/MS quantification method capable of quantifying both SCH23390 and raclopride, selectively addressing D 1 and D 2 receptors, respectively, was established and validated for this purpose. Based thereon, simultaneous saturation and competition experiments with SCH23390 and raclopride in the presence of both D 1 and D 2 receptors were performed and analyzed by LC-MS/MS within a single chromatographic cycle. The present study thus demonstrates the feasibility of this strategy and the high versatility of MS Binding Assays that appears to surpass that common for conventional radioligand binding assays. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. System and process for pulsed multiple reaction monitoring

    Science.gov (United States)

    Belov, Mikhail E

    2013-05-17

    A new pulsed multiple reaction monitoring process and system are disclosed that uses a pulsed ion injection mode for use in conjunction with triple-quadrupole instruments. The pulsed injection mode approach reduces background ion noise at the detector, increases amplitude of the ion signal, and includes a unity duty cycle that provides a significant sensitivity increase for reliable quantitation of proteins/peptides present at attomole levels in highly complex biological mixtures.

  9. Multisensor Capacitance Probes for Simultaneously Monitoring Rice Field Soil-Water- Crop-Ambient Conditions.

    Science.gov (United States)

    Brinkhoff, James; Hornbuckle, John; Dowling, Thomas

    2017-12-26

    Multisensor capacitance probes (MCPs) have traditionally been used for soil moisture monitoring and irrigation scheduling. This paper presents a new application of these probes, namely the simultaneous monitoring of ponded water level, soil moisture, and temperature profile, conditions which are particularly important for rice crops in temperate growing regions and for rice grown with prolonged periods of drying. WiFi-based loggers are used to concurrently collect the data from the MCPs and ultrasonic distance sensors (giving an independent reading of water depth). Models are fit to MCP water depth vs volumetric water content (VWC) characteristics from laboratory measurements, variability from probe-to-probe is assessed, and the methodology is verified using measurements from a rice field throughout a growing season. The root-mean-squared error of the water depth calculated from MCP VWC over the rice growing season was 6.6 mm. MCPs are used to simultaneously monitor ponded water depth, soil moisture content when ponded water is drained, and temperatures in root, water, crop and ambient zones. The insulation effect of ponded water against cold-temperature effects is demonstrated with low and high water levels. The developed approach offers advantages in gaining the full soil-plant-atmosphere continuum in a single robust sensor.

  10. Simultaneous monitoring of ice accretion and thermography of an airfoil: an IR imaging methodology

    International Nuclear Information System (INIS)

    Mohseni, M; Frioult, M; Amirfazli, A

    2012-01-01

    A novel image analysis methodology based on infrared (IR) imaging was developed for simultaneous monitoring of ice accretion and thermography of airfoils. In this study, an IR camera was calibrated and used to measure the surface temperature of the energized airfoils, and monitor the ice accretion and growth pattern on the airfoils’ surfaces. The methodology comprises the automatic processing of a series of IR video frames with the purpose of detecting ice pattern evolution during the icing test period. A specially developed MATLAB code was used to detect the iced areas in the IR images, and simultaneously monitor surface temperature evolution of the airfoil during an icing test. Knowing the correlation between the icing pattern and surface temperature changes during an icing test is essential for energy efficient design of thermal icing mitigation systems. Processed IR images were also used to determine the ice accumulation rate on the airfoil's surface in a given icing test. The proposed methodology has been demonstrated to work successfully, since the optical images taken at the end of icing tests from the airfoils’ surfaces compared well with the processed IR images detecting the ice grown outward from the airfoils’ leading edge area. (paper)

  11. Simultaneous synthesis of anatase colloidal and multiple-branched rutile TiO{sub 2} nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Trong Tung; Duong, Ngoc Huyen [School of Engineering Physics, Hanoi University of Science and Technology, Hanoi (Viet Nam); Mai, Xuan Dung [Dept. of Chemistry, Hanoi Pedagogical University No2, Vinh Phuc (Viet Nam)

    2017-03-15

    Facile synthesis of titanium dioxide (TiO{sub 2} ) nanostructures with controllability over their cystallinity, dimensions, and shape is in demand for diverse optoelectronic applications. Anatase colloidal particles and precipitates of rutile bundles were synthesized simultaneously using HCl catalyzed sol–gel process with titanium tetrachloride as Ti precursor. The crystallinity and the morphology of these two separable TiO{sub 2} phases were studied by X-ray diffraction, Raman spectroscopy, and transmission electron microscopy. The results show that by varying HCl concentration during synthesis, dimensions of colloidal anatase can be tuned from spherical particles with a diameter of 2–5 nm to nanorods of dimension of 4 nm (width) × 14 nm (length). The rutile bundles whose size increased with aging time consisted of multiple branches with elongation along c-axis. Both anatase nanorods and rutile bundles can be applied as highly efficient photocatalysts or electron conduits.

  12. Aptamer- and nucleic acid enzyme-based systems for simultaneous detection of multiple analytes

    Science.gov (United States)

    Lu, Yi [Champaign, IL; Liu, Juewen [Albuquerque, NM

    2011-11-15

    The present invention provides aptamer- and nucleic acid enzyme-based systems for simultaneously determining the presence and optionally the concentration of multiple analytes in a sample. Methods of utilizing the system and kits that include the sensor components are also provided. The system includes a first reactive polynucleotide that reacts to a first analyte; a second reactive polynucleotide that reacts to a second analyte; a third polynucleotide; a fourth polynucleotide; a first particle, coupled to the third polynucleotide; a second particle, coupled to the fourth polynucleotide; and at least one quencher, for quenching emissions of the first and second quantum dots, coupled to the first and second reactive polynucleotides. The first particle includes a quantum dot having a first emission wavelength. The second particle includes a second quantum dot having a second emission wavelength different from the first emission wavelength. The third polynucleotide and the fourth polynucleotide are different.

  13. Simultaneous Calibration: A Joint Optimization Approach for Multiple Kinect and External Cameras.

    Science.gov (United States)

    Liao, Yajie; Sun, Ying; Li, Gongfa; Kong, Jianyi; Jiang, Guozhang; Jiang, Du; Cai, Haibin; Ju, Zhaojie; Yu, Hui; Liu, Honghai

    2017-06-24

    Camera calibration is a crucial problem in many applications, such as 3D reconstruction, structure from motion, object tracking and face alignment. Numerous methods have been proposed to solve the above problem with good performance in the last few decades. However, few methods are targeted at joint calibration of multi-sensors (more than four devices), which normally is a practical issue in the real-time systems. In this paper, we propose a novel method and a corresponding workflow framework to simultaneously calibrate relative poses of a Kinect and three external cameras. By optimizing the final cost function and adding corresponding weights to the external cameras in different locations, an effective joint calibration of multiple devices is constructed. Furthermore, the method is tested in a practical platform, and experiment results show that the proposed joint calibration method can achieve a satisfactory performance in a project real-time system and its accuracy is higher than the manufacturer's calibration.

  14. A signal processing framework for simultaneous detection of multiple environmental contaminants

    International Nuclear Information System (INIS)

    Chakraborty, Subhadeep; Mench, Matthew M; Manahan, Michael P

    2013-01-01

    The possibility of large-scale attacks using chemical warfare agents (CWAs) has exposed the critical need for fundamental research enabling the reliable, unambiguous and early detection of trace CWAs and toxic industrial chemicals. This paper presents a unique approach for the identification and classification of simultaneously present multiple environmental contaminants by perturbing an electrochemical (EC) sensor with an oscillating potential for the extraction of statistically rich information from the current response. The dynamic response, being a function of the degree and mechanism of contamination, is then processed with a symbolic dynamic filter for the extraction of representative patterns, which are then classified using a trained neural network. The approach presented in this paper promises to extend the sensing power and sensitivity of these EC sensors by augmenting and complementing sensor technology with state-of-the-art embedded real-time signal processing capabilities. (paper)

  15. Simultaneous Structural Variation Discovery in Multiple Paired-End Sequenced Genomes

    Science.gov (United States)

    Hormozdiari, Fereydoun; Hajirasouliha, Iman; McPherson, Andrew; Eichler, Evan E.; Sahinalp, S. Cenk

    Next generation sequencing technologies have been decreasing the costs and increasing the world-wide capacity for sequence production at an unprecedented rate, making the initiation of large scale projects aiming to sequence almost 2000 genomes [1]. Structural variation detection promises to be one of the key diagnostic tools for cancer and other diseases with genomic origin. In this paper, we study the problem of detecting structural variation events in two or more sequenced genomes through high throughput sequencing . We propose to move from the current model of (1) detecting genomic variations in single next generation sequenced (NGS) donor genomes independently, and (2) checking whether two or more donor genomes indeed agree or disagree on the variations (in this paper we name this framework Independent Structural Variation Discovery and Merging - ISV&M), to a new model in which we detect structural variation events among multiple genomes simultaneously.

  16. Simultaneous Measurement of Multiple Mechanical Properties of Single Cells Using AFM by Indentation and Vibration.

    Science.gov (United States)

    Zhang, Chuang; Shi, Jialin; Wang, Wenxue; Xi, Ning; Wang, Yuechao; Liu, Lianqing

    2017-12-01

    The mechanical properties of cells, which are the main characteristics determining their physical performance and physiological functions, have been actively studied in the fields of cytobiology and biomedical engineering and for the development of medicines. In this study, an indentation-vibration-based method is proposed to simultaneously measure the mechanical properties of cells in situ, including cellular mass (m), elasticity (k), and viscosity (c). The proposed measurement method is implemented based on the principle of forced vibration stimulated by simple harmonic force using an atomic force microscope (AFM) system integrated with a piezoelectric transducer as the substrate vibrator. The corresponding theoretical model containing the three mechanical properties is derived and used to perform simulations and calculations. Living and fixed human embryonic kidney 293 (HEK 293) cells were subjected to indentation and vibration to measure and compare their mechanical parameters and verify the proposed approach. The results that the fixed sample cells are more viscous and elastic than the living sample cells and the measured mechanical properties of cell are consistent within, but not outside of the central region of the cell, are in accordance with the previous studies. This work provides an approach to simultaneous measurement of the multiple mechanical properties of single cells using an integrated AFM system based on the principle force vibration and thickness-corrected Hertz model. This study should contribute to progress in biomedical engineering, cytobiology, medicine, early diagnosis, specific therapy and cell-powered robots.

  17. Simultaneous bioaccumulation of multiple metals from electroplating effluent using Aspergillus lentulus.

    Science.gov (United States)

    Mishra, Abhishek; Malik, Anushree

    2012-10-15

    Toxic impacts of heavy metals in the environment have lead to intensive research on various methods of heavy metal remediation. However, in spite of abundant work on heavy metals removal from simple synthetic solutions, a very few studies demonstrate the potential of microbial strains for the treatment of industrial effluents containing mixtures of metals. In the present study, the efficiency of an environmental isolate (Aspergillus lentulusFJ172995), for simultaneous removal of chromium, copper and lead from a small-scale electroplating industry effluent was investigated. Initial studies with synthetic solutions infer that A. lentulus has a remarkable tolerance against Cr, Cu, Pb and Ni. During its growth, a significant bioaccumulation of individual metal was recorded. After 5 d of growth, the removal of metals from synthetic solutions followed the trend Pb(2+) (100%) > Cr(3+) (79%) > Cu(2+) (78%), > Ni(2+) (42%). When this strain was applied to the treatment of multiple metal containing electroplating effluent (after pH adjustment), the metal concentrations decreased by 71%, 56% and 100% for Cr, Cu and Pb, respectively within 11 d. Based on our results, we propose that the simultaneous removal of hazardous metals from industrial effluents can be accomplished using A. lentulus. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Blends of Pheromones, With and Without Host Plant Volatiles, Can Attract Multiple Species of Cerambycid Beetles Simultaneously

    Science.gov (United States)

    L.M. Hanks; J.A. Mongold-Diers; T.H. Atkinson; M.K. Fierke; M.D. Ginzel; E.E. Graham; T.M. Poland; A.B. Richards; M.L. Richardson; J.G. Millar

    2018-01-01

    Pheromone components of cerambycid beetles are often conserved, with a given compound serving as a pheromone component for multiple related species, including species native to different continents. Consequently, a single synthesized compound may attract multiple species to a trap simultaneously. Furthermore, our previous research in east-central Illinois had...

  19. MITIE: Simultaneous RNA-Seq-based transcript identification and quantification in multiple samples.

    Science.gov (United States)

    Behr, Jonas; Kahles, André; Zhong, Yi; Sreedharan, Vipin T; Drewe, Philipp; Rätsch, Gunnar

    2013-10-15

    High-throughput sequencing of mRNA (RNA-Seq) has led to tremendous improvements in the detection of expressed genes and reconstruction of RNA transcripts. However, the extensive dynamic range of gene expression, technical limitations and biases, as well as the observed complexity of the transcriptional landscape, pose profound computational challenges for transcriptome reconstruction. We present the novel framework MITIE (Mixed Integer Transcript IdEntification) for simultaneous transcript reconstruction and quantification. We define a likelihood function based on the negative binomial distribution, use a regularization approach to select a few transcripts collectively explaining the observed read data and show how to find the optimal solution using Mixed Integer Programming. MITIE can (i) take advantage of known transcripts, (ii) reconstruct and quantify transcripts simultaneously in multiple samples, and (iii) resolve the location of multi-mapping reads. It is designed for genome- and assembly-based transcriptome reconstruction. We present an extensive study based on realistic simulated RNA-Seq data. When compared with state-of-the-art approaches, MITIE proves to be significantly more sensitive and overall more accurate. Moreover, MITIE yields substantial performance gains when used with multiple samples. We applied our system to 38 Drosophila melanogaster modENCODE RNA-Seq libraries and estimated the sensitivity of reconstructing omitted transcript annotations and the specificity with respect to annotated transcripts. Our results corroborate that a well-motivated objective paired with appropriate optimization techniques lead to significant improvements over the state-of-the-art in transcriptome reconstruction. MITIE is implemented in C++ and is available from http://bioweb.me/mitie under the GPL license.

  20. Comparing apples and oranges: fold-change detection of multiple simultaneous inputs.

    Directory of Open Access Journals (Sweden)

    Yuval Hart

    Full Text Available Sensory systems often detect multiple types of inputs. For example, a receptor in a cell-signaling system often binds multiple kinds of ligands, and sensory neurons can respond to different types of stimuli. How do sensory systems compare these different kinds of signals? Here, we consider this question in a class of sensory systems - including bacterial chemotaxis- which have a property known as fold-change detection: their output dynamics, including amplitude and response time, depends only on the relative changes in signal, rather than absolute changes, over a range of several decades of signal. We analyze how fold-change detection systems respond to multiple signals, using mathematical models. Suppose that a step of fold F1 is made in input 1, together with a step of F2 in input 2. What total response does the system provide? We show that when both input signals impact the same receptor with equal number of binding sites, the integrated response is multiplicative: the response dynamics depend only on the product of the two fold changes, F1F2. When the inputs bind the same receptor with different number of sites n1 and n2, the dynamics depend on a product of power laws, [Formula: see text]. Thus, two input signals which vary over time in an inverse way can lead to no response. When the two inputs affect two different receptors, other types of integration may be found and generally the system is not constrained to respond according to the product of the fold-change of each signal. These predictions can be readily tested experimentally, by providing cells with two simultaneously varying input signals. The present study suggests how cells can compare apples and oranges, namely by comparing each to its own background level, and then multiplying these two fold-changes.

  1. Simultaneous assimilation of ozone profiles from multiple UV-VIS satellite instruments

    Science.gov (United States)

    van Peet, Jacob C. A.; van der A, Ronald J.; Kelder, Hennie M.; Levelt, Pieternel F.

    2018-02-01

    A three-dimensional global ozone distribution has been derived from assimilation of ozone profiles that were observed by satellites. By simultaneous assimilation of ozone profiles retrieved from the nadir looking satellite instruments Global Ozone Monitoring Experiment 2 (GOME-2) and Ozone Monitoring Instrument (OMI), which measure the atmosphere at different times of the day, the quality of the derived atmospheric ozone field has been improved. The assimilation is using an extended Kalman filter in which chemical transport model TM5 has been used for the forecast. The combined assimilation of both GOME-2 and OMI improves upon the assimilation results of a single sensor. The new assimilation system has been demonstrated by processing 4 years of data from 2008 to 2011. Validation of the assimilation output by comparison with sondes shows that biases vary between -5 and +10 % between the surface and 100 hPa. The biases for the combined assimilation vary between -3 and +3 % in the region between 100 and 10 hPa where GOME-2 and OMI are most sensitive. This is a strong improvement compared to direct retrievals of ozone profiles from satellite observations.

  2. Simultaneous imaging of multiple neurotransmitters and neuroactive substances in the brain by desorption electrospray ionization mass spectrometry

    OpenAIRE

    Shariatgorji, Mohammadreza; Strittmatter, Nicole; Nilsson, Anna; Kallbäck, Patrik; Alvarsson, Alexandra; Zhang, Xiaoqun; Vallianatou, Theodosia; Svenningsson, Per; Goodwin, Richard J. A.; Andrén, Per E.

    2016-01-01

    With neurological processes involving multiple neurotransmitters and neuromodulators, it is important to have the ability to directly map and quantify multiple signaling molecules simultaneously in a single analysis. By utilizing a molecular-specific approach, namely desorption electrospray ionization mass spectrometry imaging (DESI-MSI), we demonstrated that the technique can be used to image multiple neurotransmitters and their metabolites (dopamine, dihydroxyphenylacetic acid, 3-methoxytyr...

  3. Microseismic Monitoring Design Optimization Based on Multiple Criteria Decision Analysis

    Science.gov (United States)

    Kovaleva, Y.; Tamimi, N.; Ostadhassan, M.

    2017-12-01

    Borehole microseismic monitoring of hydraulic fracture treatments of unconventional reservoirs is a widely used method in the oil and gas industry. Sometimes, the quality of the acquired microseismic data is poor. One of the reasons for poor data quality is poor survey design. We attempt to provide a comprehensive and thorough workflow, using multiple criteria decision analysis (MCDA), to optimize planning micriseismic monitoring. So far, microseismic monitoring has been used extensively as a powerful tool for determining fracture parameters that affect the influx of formation fluids into the wellbore. The factors that affect the quality of microseismic data and their final results include average distance between microseismic events and receivers, complexity of the recorded wavefield, signal-to-noise ratio, data aperture, etc. These criteria often conflict with each other. In a typical microseismic monitoring, those factors should be considered to choose the best monitoring well(s), optimum number of required geophones, and their depth. We use MDCA to address these design challenges and develop a method that offers an optimized design out of all possible combinations to produce the best data acquisition results. We believe that this will be the first research to include the above-mentioned factors in a 3D model. Such a tool would assist companies and practicing engineers in choosing the best design parameters for future microseismic projects.

  4. Simultaneous estimation of multiple phases in digital holographic interferometry using state space analysis

    Science.gov (United States)

    Kulkarni, Rishikesh; Rastogi, Pramod

    2018-05-01

    A new approach is proposed for the multiple phase estimation from a multicomponent exponential phase signal recorded in multi-beam digital holographic interferometry. It is capable of providing multidimensional measurements in a simultaneous manner from a single recording of the exponential phase signal encoding multiple phases. Each phase within a small window around each pixel is appproximated with a first order polynomial function of spatial coordinates. The problem of accurate estimation of polynomial coefficients, and in turn the unwrapped phases, is formulated as a state space analysis wherein the coefficients and signal amplitudes are set as the elements of a state vector. The state estimation is performed using the extended Kalman filter. An amplitude discrimination criterion is utilized in order to unambiguously estimate the coefficients associated with the individual signal components. The performance of proposed method is stable over a wide range of the ratio of signal amplitudes. The pixelwise phase estimation approach of the proposed method allows it to handle the fringe patterns that may contain invalid regions.

  5. Weighted least-square approach for simultaneous measurement of multiple reflective surfaces

    Science.gov (United States)

    Tang, Shouhong; Bills, Richard E.; Freischlad, Klaus

    2007-09-01

    Phase shifting interferometry (PSI) is a highly accurate method for measuring the nanometer-scale relative surface height of a semi-reflective test surface. PSI is effectively used in conjunction with Fizeau interferometers for optical testing, hard disk inspection, and semiconductor wafer flatness. However, commonly-used PSI algorithms are unable to produce an accurate phase measurement if more than one reflective surface is present in the Fizeau interferometer test cavity. Examples of test parts that fall into this category include lithography mask blanks and their protective pellicles, and plane parallel optical beam splitters. The plane parallel surfaces of these parts generate multiple interferograms that are superimposed in the recording plane of the Fizeau interferometer. When using wavelength shifting in PSI the phase shifting speed of each interferogram is proportional to the optical path difference (OPD) between the two reflective surfaces. The proposed method is able to differentiate each underlying interferogram from each other in an optimal manner. In this paper, we present a method for simultaneously measuring the multiple test surfaces of all underlying interferograms from these superimposed interferograms through the use of a weighted least-square fitting technique. The theoretical analysis of weighted least-square technique and the measurement results will be described in this paper.

  6. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    Science.gov (United States)

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  7. Simultaneous recording of EEG and electromyographic polygraphy increases the diagnostic yield of video-EEG monitoring.

    Science.gov (United States)

    Hill, Aron T; Briggs, Belinda A; Seneviratne, Udaya

    2014-06-01

    To investigate the usefulness of adjunctive electromyographic (EMG) polygraphy in the diagnosis of clinical events captured during long-term video-EEG monitoring. A total of 40 patients (21 women, 19 men) aged between 19 and 72 years (mean 43) investigated using video-EEG monitoring were studied. Electromyographic activity was simultaneously recorded with EEG in four patients selected on clinical grounds. In these patients, surface EMG electrodes were placed over muscles suspected to be activated during a typical clinical event. Of the 40 patients investigated, 24 (60%) were given a diagnosis, whereas 16 (40%) remained undiagnosed. All four patients receiving adjunctive EMG polygraphy obtained a diagnosis, with three of these diagnoses being exclusively reliant on the EMG recordings. Specifically, one patient was diagnosed with propriospinal myoclonus, another patient was diagnosed with facio-mandibular myoclonus, and a third patient was found to have bruxism and periodic leg movements of sleep. The information obtained from surface EMG recordings aided the diagnosis of clinical events captured during video-EEG monitoring in 7.5% of the total cohort. This study suggests that EEG-EMG polygraphy may be used as a technique of improving the diagnostic yield of video-EEG monitoring in selected cases.

  8. Quantitative monitoring of two simultaneously binding species using Label-Enhanced surface plasmon resonance.

    Science.gov (United States)

    Eng, Lars; Garcia, Brandon L; Geisbrecht, Brian V; Hanning, Anders

    2018-02-26

    Surface plasmon resonance (SPR) is a well-established method for biomolecular interaction studies. SPR monitors the binding of molecules to a solid surface, embodied as refractive index changes close to the surface. One limitation of conventional SPR is the universal nature of the detection that results in an inability to qualitatively discriminate between different binding species. Furthermore, it is impossible to directly discriminate two species simultaneously binding to different sites on a protein, which limits the utility of SPR, for example, in the study of allosteric binders or bi-specific molecules. It is also impossible in principle to discriminate protein conformation changes from actual binding events. Here we demonstrate how Label-Enhanced SPR can be utilized to discriminate and quantitatively monitor the simultaneous binding of two different species - one dye-labeled and one unlabeled - on a standard, single-wavelength SPR instrument. This new technique increases the versatility of SPR technology by opening up application areas where the usefulness of the approach has previously been limited. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

    International Nuclear Information System (INIS)

    Jang, Jeong Won; Kay, Chul Seung; You, Chan Ran; Kim, Chang Wook; Bae, Si Hyun.; Choi, Jong Young; Yoon, Seung Kew; Han, Chi Wha; Jung, Hyun Suk; Choi, Ihl Bong

    2009-01-01

    Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for ≤1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

  10. Flexible carbon nanotube nanocomposite sensor for multiple physiological parameter monitoring

    KAUST Repository

    Nag, Anindya

    2016-10-16

    The paper presents the design, development, and fabrication of a flexible and wearable sensor based on carbon nanotube nanocomposite for monitoring specific physiological parameters. Polydimethylsiloxane (PDMS) was used as the substrate with a thin layer of a nanocomposite comprising functionalized multi-walled carbon nanotubes (MWCNTs) and PDMS as electrodes. The sensor patch functionalized on strain-sensitive capacitive sensing from interdigitated electrodes which were patterned with a laser on the nanocomposite layer. The thickness of the electrode layer was optimized regarding strain and conductivity. The sensor patch was connected to a monitoring device from one end and attached to the body on the other for examining purposes. Experimental results show the capability of the sensor patch used to detect respiration and limb movements. This work is a stepping stone of the sensing system to be developed for multiple physiological parameters.

  11. Flexible carbon nanotube nanocomposite sensor for multiple physiological parameter monitoring

    KAUST Repository

    Nag, Anindya; Mukhopadhyay, Subhas Chandra; Kosel, Jü rgen

    2016-01-01

    The paper presents the design, development, and fabrication of a flexible and wearable sensor based on carbon nanotube nanocomposite for monitoring specific physiological parameters. Polydimethylsiloxane (PDMS) was used as the substrate with a thin layer of a nanocomposite comprising functionalized multi-walled carbon nanotubes (MWCNTs) and PDMS as electrodes. The sensor patch functionalized on strain-sensitive capacitive sensing from interdigitated electrodes which were patterned with a laser on the nanocomposite layer. The thickness of the electrode layer was optimized regarding strain and conductivity. The sensor patch was connected to a monitoring device from one end and attached to the body on the other for examining purposes. Experimental results show the capability of the sensor patch used to detect respiration and limb movements. This work is a stepping stone of the sensing system to be developed for multiple physiological parameters.

  12. Determine Multiple Elements Simultaneously in the Sera of Umbilical Cord Blood Samples-a Very Simple Method.

    Science.gov (United States)

    Liang, Chunmei; Li, Zhijuan; Xia, Xun; Wang, Qunan; Tao, Ruiwen; Tao, Yiran; Xiang, Haiyun; Tong, Shilu; Tao, Fangbiao

    2017-05-01

    Analyzing the concentrations of heavy metals in the sera of umbilical cord blood samples can provide useful information about prenatal exposure to environmental agents. An analytical method based on ICP-MS to simultaneously determine multiple elements in umbilical cord blood samples was developed for assessing the in utero exposure to metallic and metalloid elements. The method only required as little as 100 μL of serum diluted 1:25 for direct analysis. Matrix-matched protocol was used to eliminate mass matrix interference and kinetic energy discrimination mode was used to eliminate the polyatomic ion interference. The assay was completed on average within 4 min with the detection limits ranging from 0.0002 to 44.4 μg/L for all the targeted elements. The detection rates for most of elements were 100 % other than cadmium (Cd), lead (Pb), and mercury (Hg). The testing results of the certified reference materials were ideal. The method is simple and sensitive, so it is suitable for the monitoring of large quantities of samples.

  13. The multiple stressor effect in zebrafish embryos from simultaneous exposure to ionising radiation and cadmium

    International Nuclear Information System (INIS)

    Ng, C Y P; Choi, V W Y; Lam, A C L; Yu, K N; Cheng, S H

    2013-01-01

    Living organisms are exposed to a mixture of environmental stressors, and the resultant effects are referred to as multiple stressor effects. In the present work, we studied the multiple stressor effect in embryos of the zebrafish (Danio rerio) from simultaneous exposure to ionising radiation (alpha particles) and cadmium through quantification of apoptotic signals at 24 h postfertilisation (hpf) revealed by vital dye acridine orange staining. For each set of experiments, 32–40 dechorionated embryos were deployed, which were divided into four groups each having 8–10 embryos. The four groups of embryos were referred to as (1) the control group (C), which received no further treatments after dechorionation; (2) the Cd-dosed and irradiated group (CdIr), which was exposed to 100 μM Cd from 5 to 24 hpf, and also received about 4.4 mGy from alpha particles at 5 hpf; (3) the irradiated group (Ir), which received about 4.4 mGy from alpha particles at 5 hpf; and (4) the Cd-dosed group (Cd), which was exposed to 100 μM Cd from 5 to 24 hpf. In general, the CdIr, Ir and Cd groups had more apoptotic signals than the C group. Within the 12 sets of experimental results, two showed significant synergistic effects, one showed a weakly synergistic effect and nine showed additive effects. The multiple stressor effect of 100 μM Cd with ∼4.4 mGy alpha-particle radiation resulted in an additive or synergistic effect, but no antagonistic effect. The failure to identify significant synergistic effects for some sets of data, and thus their subsequent classification as additive effects, might be a result of the relatively small magnitude of the synergistic effects. The results showed that the radiation risk could be perturbed by another environmental stressor such as a heavy metal, and as such a realistic human radiation risk assessment should in general take into account the multiple stressor effects. (paper)

  14. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device

    NARCIS (Netherlands)

    De Lima Braga Lopes Cordeiro, Carlos; de Vries, M.G.; Ngabi, W; Oomen, P.E.; Cremers, T.I.F.H.; Westerink, B.H.C.

    2015-01-01

    Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will

  15. Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery

    International Nuclear Information System (INIS)

    Li Kaile; Dai Jianrong; Ma Lijun

    2004-01-01

    Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment between segments. We implemented and demonstrated our method for multiple clinical cases. We compared the results of our method with the results from exhaustive search method. We found that our solution without leaf end abutment produced equivalent results to the unconstrained solutions in terms of minimum total monitor units and minimum number of leaf segments. We conclude that the leaf end abutment fields can be avoided without affecting the efficiency of segmental IMRT delivery. The major strength of our method is its simplicity and high computing speed. This potentially provides a useful means for generating segmental IMRT fields that require high spatial resolution or complex intensity distributions

  16. Breeding approaches in simultaneous selection for multiple stress tolerance of maize in tropical environments

    Directory of Open Access Journals (Sweden)

    Denić M.

    2007-01-01

    Full Text Available Maize is the principal crop and major staple food in the most countries of Sub-Saharan Africa. However, due to the influence of abiotic and biotic stress factors, maize production faces serious constraints. Among the agro-ecological conditions, the main constraints are: lack and poor distribution of rainfall; low soil fertility; diseases (maize streak virus, downy mildew, leaf blights, rusts, gray leaf spot, stem/cob rots and pests (borers and storage pests. Among the socio-economic production constraints are: poor economy, serious shortage of trained manpower; insufficient management expertise, lack of use of improved varieties and poor cultivation practices. To develop desirable varieties, and thus consequently alleviate some of these constraints, appropriate breeding approaches and field-based methodologies in selection for multiple stress tolerance, were implemented. These approaches are mainly based on: a Crossing selected genotypes with more desirable stress tolerant and other agronomic traits; b Using the disease/pest spreader row method, combined with testing and selection of created progenies under strong to intermediate pressure of drought and low soil fertility in nurseries; and c Evaluation of the varieties developed in multi-location trials under low and "normal" inputs. These approaches provide testing and selection of large number of progenies, which is required for simultaneous selection for multiple stress tolerance. Data obtained revealed that remarkable improvement of the traits under selection was achieved. Biggest progress was obtained in selection for maize streak virus and downy mildew resistance, flintiness and earliness. In the case of drought stress, statistical analyses revealed significant negative correlation between yield and anthesis-silking interval, and between yield and days to silk, but positive correlation between yield and grain weight per ear.

  17. First Simulations of Designing Stratospheric Sulfate Aerosol Geoengineering to Meet Multiple Simultaneous Climate Objectives

    Science.gov (United States)

    Kravitz, Ben; MacMartin, Douglas G.; Mills, Michael J.; Richter, Jadwiga H.; Tilmes, Simone; Lamarque, Jean-Francois; Tribbia, Joseph J.; Vitt, Francis

    2017-12-01

    We describe the first simulations of stratospheric sulfate aerosol geoengineering using multiple injection locations to meet multiple simultaneous surface temperature objectives. Simulations were performed using CESM1(WACCM), a coupled atmosphere-ocean general circulation model with fully interactive stratospheric chemistry, dynamics (including an internally generated quasi-biennial oscillation), and a sophisticated treatment of sulfate aerosol formation, microphysical growth, and deposition. The objectives are defined as maintaining three temperature features at their 2020 levels against a background of the RCP8.5 scenario over the period 2020-2099. These objectives are met using a feedback mechanism in which the rate of sulfur dioxide injection at each of the four locations is adjusted independently every year of simulation. Even in the presence of uncertainties, nonlinearities, and variability, the objectives are met, predominantly by SO2 injection at 30°N and 30°S. By the last year of simulation, the feedback algorithm calls for a total injection rate of 51 Tg SO2 per year. The injections are not in the tropics, which results in a greater degree of linearity of the surface climate response with injection amount than has been found in many previous studies using injection at the equator. Because the objectives are defined in terms of annual mean temperature, the required geongineering results in "overcooling" during summer and "undercooling" during winter. The hydrological cycle is also suppressed as compared to the reference values corresponding to the year 2020. The demonstration we describe in this study is an important step toward understanding what geoengineering can do and what it cannot do.

  18. Monitoring and surveillance for multiple micronutrient supplements in pregnancy.

    Science.gov (United States)

    Mei, Zuguo; Jefferds, Maria Elena; Namaste, Sorrel; Suchdev, Parminder S; Flores-Ayala, Rafael C

    2017-12-22

    The World Health Organization (WHO) recommends iron-folic acid (IFA) supplementation during pregnancy to improve maternal and infant health outcomes. Multiple micronutrient (MMN) supplementation in pregnancy has been implemented in select countries and emerging evidence suggests that MMN supplementation in pregnancy may provide additional benefits compared to IFA alone. In 2015, WHO, the United Nations Children's Fund (UNICEF), and the Micronutrient Initiative held a "Technical Consultation on MMN supplements in pregnancy: implementation considerations for successful incorporation into existing programmemes," which included a call for indicators needed for monitoring, evaluation, and surveillance of MMN supplementation programmes. Currently, global surveillance and monitoring data show that overall IFA supplementation programmes suffer from low coverage and intake adherence, despite inclusion in national policies. Common barriers that limit the effectiveness of IFA-which also apply to MMN programmes-include weak supply chains, low access to antenatal care services, low-quality behaviour change interventions to support and motivate women, and weak or non-existent monitoring systems used for programme improvement. The causes of these barriers in a given country need careful review to resolve them. As countries heighten their focus on supplementation during pregnancy, or if they decide to initiate or transition into MMN supplementation, a priority is to identify key monitoring indicators to address these issues and support effective programmes. National and global monitoring and surveillance data on IFA supplementation during pregnancy are primarily derived from cross-sectional surveys and, on a more routine basis, through health and logistics management information systems. Indicators for IFA supplementation exist; however, the new indicators for MMN supplementation need to be incorporated. We reviewed practice-based evidence, guided by the WHO/Centers for Disease

  19. Simultaneous and sequential hemorrhage of multiple cerebral cavernous malformations: a case report.

    Science.gov (United States)

    Louis, Nundia; Marsh, Robert

    2016-02-09

    The etiology of cerebral cavernous malformation hemorrhage is not well understood. Causative physiologic parameters preceding hemorrhagic cavernous malformation events are often not reported. We present a case of an individual with sequential simultaneous hemorrhages in multiple cerebral cavernous malformations with a new onset diagnosis of hypertension. A 42-year-old white man was admitted to our facility with worsening headache, left facial and tongue numbness, dizziness, diplopia, and elevated blood pressure. His past medical history was significant for new onset diagnosis of hypertension and chronic seasonal allergies. Serial imaging over the ensuing 8 days revealed sequential hemorrhagic lesions. He underwent suboccipital craniotomy for resection of the lesions located in the fourth ventricle and right cerebellum. One month after surgery, he had near complete resolution of his symptoms with mild residual vertigo but symptomatic chronic hypertension. Many studies have focused on genetic and inflammatory mechanisms contributing to cerebral cavernous malformation rupture, but few have reported on the potential of hemodynamic changes contributing to cerebral cavernous malformation rupture. Systemic blood pressure changes clearly have an effect on angioma pressures. When considering the histopathological features of cerebral cavernous malformation architecture, changes in arterial pressure could cause meaningful alterations in hemorrhage propensity and patterns.

  20. Simultaneous Calibration: A Joint Optimization Approach for Multiple Kinect and External Cameras

    Directory of Open Access Journals (Sweden)

    Yajie Liao

    2017-06-01

    Full Text Available Camera calibration is a crucial problem in many applications, such as 3D reconstruction, structure from motion, object tracking and face alignment. Numerous methods have been proposed to solve the above problem with good performance in the last few decades. However, few methods are targeted at joint calibration of multi-sensors (more than four devices, which normally is a practical issue in the real-time systems. In this paper, we propose a novel method and a corresponding workflow framework to simultaneously calibrate relative poses of a Kinect and three external cameras. By optimizing the final cost function and adding corresponding weights to the external cameras in different locations, an effective joint calibration of multiple devices is constructed. Furthermore, the method is tested in a practical platform, and experiment results show that the proposed joint calibration method can achieve a satisfactory performance in a project real-time system and its accuracy is higher than the manufacturer’s calibration.

  1. Modular time division multiplexer: Efficient simultaneous characterization of fast and slow transients in multiple samples

    Science.gov (United States)

    Kim, Stephan D.; Luo, Jiajun; Buchholz, D. Bruce; Chang, R. P. H.; Grayson, M.

    2016-09-01

    A modular time division multiplexer (MTDM) device is introduced to enable parallel measurement of multiple samples with both fast and slow decay transients spanning from millisecond to month-long time scales. This is achieved by dedicating a single high-speed measurement instrument for rapid data collection at the start of a transient, and by multiplexing a second low-speed measurement instrument for slow data collection of several samples in parallel for the later transients. The MTDM is a high-level design concept that can in principle measure an arbitrary number of samples, and the low cost implementation here allows up to 16 samples to be measured in parallel over several months, reducing the total ensemble measurement duration and equipment usage by as much as an order of magnitude without sacrificing fidelity. The MTDM was successfully demonstrated by simultaneously measuring the photoconductivity of three amorphous indium-gallium-zinc-oxide thin films with 20 ms data resolution for fast transients and an uninterrupted parallel run time of over 20 days. The MTDM has potential applications in many areas of research that manifest response times spanning many orders of magnitude, such as photovoltaics, rechargeable batteries, amorphous semiconductors such as silicon and amorphous indium-gallium-zinc-oxide.

  2. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  3. Simultaneous Fault Detection and Sensor Selection for Condition Monitoring of Wind Turbines

    Directory of Open Access Journals (Sweden)

    Wenna Zhang

    2016-04-01

    Full Text Available Data collected from the supervisory control and data acquisition (SCADA system are used widely in wind farms to obtain operation and performance information about wind turbines. The paper presents a three-way model by means of parallel factor analysis (PARAFAC for wind turbine fault detection and sensor selection, and evaluates the method with SCADA data obtained from an operational farm. The main characteristic of this new approach is that it can be used to simultaneously explore measurement sample profiles and sensors profiles to avoid discarding potentially relevant information for feature extraction. With K-means clustering method, the measurement data indicating normal, fault and alarm conditions of the wind turbines can be identified, and the sensor array can be optimised for effective condition monitoring.

  4. Simultaneous Monitoring of Glucose and Lactate by Self-powered Biosensor

    Directory of Open Access Journals (Sweden)

    Ankit Baingane

    2017-07-01

    Full Text Available A dual self-powered biosensing system integrated with energy amplification circuit is described, for simultaneously monitoring glucose and lactate. The self-powered biosensing system is based on the conventional enzymatic biofuel cell equipped with three 4 mm x 4 mm massively dense mesh network of multi-walled carbon nanotubes (MWCNTs bioelectrodes in parallel configuration. The bioelectrodes employed pyroquinoline quinone glucose dehydrogenase (PQQ-GDH as the biocatalyst for the glucose oxidation and D-Lactate dehydrogenase (D-LDH as the biocatalyst for lactate oxidation. A common laccase modified-MWCNTs bioelectrode served as the cathode for the reduction of molecular oxygen. Two charge pump circuits were coupled with 0.1 mF capacitors functioning as transducers. The advantages of employing capacitors were coupled with the efficient energy amplification of the charge pump circuit to amplify the power output from each of the biofuel and charge/discharge the corresponding capacitor. Under operating conditions, the open circuit voltages and short circuit current densities for 180 mg/dL glucose and 25 mM lactate were 339.2 mV and 228.75 µA/cm2 and 370 mV and 66.17 µA/cm2, respectively. The responses for glucose and lactate were linear up to 630 mg/dL and 30 mM with sensitivities of 20.11 Hz/ mM cm-2 and 9.869 Hz/ mM cm-2, respectively. The potential of the described system was demonstrated to provide stable voltage and current output that was capable of driving the charge pump circuit integrated with the capacitor for simultaneously monitoring glucose and lactate. These results were in good agreement with those previously reported.

  5. Simultaneous detection of multiple DNA targets by integrating dual-color graphene quantum dot nanoprobes and carbon nanotubes.

    Science.gov (United States)

    Qian, Zhaosheng; Shan, Xiaoyue; Chai, Lujing; Chen, Jianrong; Feng, Hui

    2014-12-01

    Simultaneous detection of multiple DNA targets was achieved based on a biocompatible graphene quantum dots (GQDs) and carbon nanotubes (CNTs) platform through spontaneous assembly between dual-color GQD-based probes and CNTs and subsequently self-recognition between DNA probes and targets. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Comparative efficacy of simultaneous versus sequential multiple health behavior change interventions among adults: A systematic review of randomised trials.

    Science.gov (United States)

    James, Erica; Freund, Megan; Booth, Angela; Duncan, Mitch J; Johnson, Natalie; Short, Camille E; Wolfenden, Luke; Stacey, Fiona G; Kay-Lambkin, Frances; Vandelanotte, Corneel

    2016-08-01

    Growing evidence points to the benefits of addressing multiple health behaviors rather than single behaviors. This review evaluates the relative effectiveness of simultaneous and sequentially delivered multiple health behavior change (MHBC) interventions. Secondary aims were to identify: a) the most effective spacing of sequentially delivered components; b) differences in efficacy of MHBC interventions for adoption/cessation behaviors and lifestyle/addictive behaviors, and; c) differences in trial retention between simultaneously and sequentially delivered interventions. MHBC intervention trials published up to October 2015 were identified through a systematic search. Eligible trials were randomised controlled trials that directly compared simultaneous and sequential delivery of a MHBC intervention. A narrative synthesis was undertaken. Six trials met the inclusion criteria and across these trials the behaviors targeted were smoking, diet, physical activity, and alcohol consumption. Three trials reported a difference in intervention effect between a sequential and simultaneous approach in at least one behavioral outcome. Of these, two trials favoured a sequential approach on smoking. One trial favoured a simultaneous approach on fat intake. There was no difference in retention between sequential and simultaneous approaches. There is limited evidence regarding the relative effectiveness of sequential and simultaneous approaches. Given only three of the six trials observed a difference in intervention effectiveness for one health behavior outcome, and the relatively consistent finding that the sequential and simultaneous approaches were more effective than a usual/minimal care control condition, it appears that both approaches should be considered equally efficacious. PROSPERO registration number: CRD42015027876. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Simultaneous rotational and vibrational CARS generation through a multiple-frequency combination technique

    International Nuclear Information System (INIS)

    Alden, M.; Bengtsson, P.E.; Edner, H.

    1987-01-01

    One most promising laser technique for probing combustion processes is coherent anti-Stokes Raman scattering (CARS), which due to its coherent nature and signal strength is applied in several real-world applications. Until today almost all CARS experiments are based on probing the population of molecular vibrational energy levels. However, there are several reasons rotational CARS, i.e. probing of rotational energy levels, may provide a complement to or even a better choice than vibrational CARS. Recently an alternative way to produce rotational CARS spectra is proposed, which is based on a multiple-frequency combination technique. The energy-level diagram for this process is presented. Two dye laser beams at ω/sub r/, and one fix frequency laser beam at ω/sub g/ are employed. ω/sub r,1/ and ω/sub r,2/ are two frequencies of many possible pairs with a frequency difference matching a rotational transition in a molecule. The excitation induced by ω/sub r,1/ and ω/sub r,2/ is then scattered by the narrowband ω/sub g/ beam resulting in a CARS beam ω/sub g/ at ω/sub g/ + ω/sub r,1/ - ω/sub r,2/. An interesting feature with this technique is that it is possible to generate simultaneously a rotational and vibrational CARS spectrum by using a double-folded boxcars phase matching approach. The authors believe that the proposed technique for producing rotational and vibration CARS spectra could be of interest, e.g., when measuring in highly turbulent flows. In this case the rotational CARS spectra could use for temperature measurements in the cooler parts, whereas vibrational CARS are to be preferred when measuring in the hotter parts

  8. Magnetic resonance imaging in monitoring of treatment of multiple sclerosis

    International Nuclear Information System (INIS)

    Bekiesinska-Figatowska, M.; Walecki, J.; Stelmasiak, Z.

    1996-01-01

    The purpose of the study was to establish the value of MR in monitoring of treatment of multiple sclerosis with new drug 2-CDA and placebo. 83 patients (51 women, 32 men) were examined - 81 of them twice, 66 - three times: before and after 6 and 12 courses of treatment. Toshiba MRT50A machine was used. After the first 6 courses of treatment the number of new plaques was twice as big in placebo group than in 2-CDA group. After 12 courses it turned out that a certain inhibitory influence of 2-CDA on new plaques' appearance was more evident after 15 than 3 months after the end of its administration. This may indicate the delayed action of 2-CDA but requires further investigation. (author)

  9. Monitoring system of multiple fire fighting based on computer vision

    Science.gov (United States)

    Li, Jinlong; Wang, Li; Gao, Xiaorong; Wang, Zeyong; Zhao, Quanke

    2010-10-01

    With the high demand of fire control in spacious buildings, computer vision is playing a more and more important role. This paper presents a new monitoring system of multiple fire fighting based on computer vision and color detection. This system can adjust to the fire position and then extinguish the fire by itself. In this paper, the system structure, working principle, fire orientation, hydrant's angle adjusting and system calibration are described in detail; also the design of relevant hardware and software is introduced. At the same time, the principle and process of color detection and image processing are given as well. The system runs well in the test, and it has high reliability, low cost, and easy nodeexpanding, which has a bright prospect of application and popularization.

  10. EFFECTIVE INDICES FOR MONITORING MENTAL WORKLOAD WHILE PERFORMING MULTIPLE TASKS.

    Science.gov (United States)

    Hsu, Bin-Wei; Wang, Mao-Jiun J; Chen, Chi-Yuan; Chen, Fang

    2015-08-01

    This study identified several physiological indices that can accurately monitor mental workload while participants performed multiple tasks with the strategy of maintaining stable performance and maximizing accuracy. Thirty male participants completed three 10-min. simulated multitasks: MATB (Multi-Attribute Task Battery) with three workload levels. Twenty-five commonly used mental workload measures were collected, including heart rate, 12 HRV (heart rate variability), 10 EEG (electroencephalography) indices (α, β, θ, α/θ, θ/β from O1-O2 and F4-C4), and two subjective measures. Analyses of index sensitivity showed that two EEG indices, θ and α/θ (F4-C4), one time-domain HRV-SDNN (standard deviation of inter-beat intervals), and four frequency-domain HRV: VLF (very low frequency), LF (low frequency), %HF (percentage of high frequency), and LF/HF were sensitive to differentiate high workload. EEG α/θ (F4-C4) and LF/HF were most effective for monitoring high mental workload. LF/HF showed the highest correlations with other physiological indices. EEG α/θ (F4-C4) showed strong correlations with subjective measures across different mental workload levels. Operation strategy would affect the sensitivity of EEG α (F4-C4) and HF.

  11. Monitoring multiple components in vinegar fermentation using Raman spectroscopy.

    Science.gov (United States)

    Uysal, Reyhan Selin; Soykut, Esra Acar; Boyaci, Ismail Hakki; Topcu, Ali

    2013-12-15

    In this study, the utility of Raman spectroscopy (RS) with chemometric methods for quantification of multiple components in the fermentation process was investigated. Vinegar, the product of a two stage fermentation, was used as a model and glucose and fructose consumption, ethanol production and consumption and acetic acid production were followed using RS and the partial least squares (PLS) method. Calibration of the PLS method was performed using model solutions. The prediction capability of the method was then investigated with both model and real samples. HPLC was used as a reference method. The results from comparing RS-PLS and HPLC with each other showed good correlations were obtained between predicted and actual sample values for glucose (R(2)=0.973), fructose (R(2)=0.988), ethanol (R(2)=0.996) and acetic acid (R(2)=0.983). In conclusion, a combination of RS with chemometric methods can be applied to monitor multiple components of the fermentation process from start to finish with a single measurement in a short time. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems.

    Science.gov (United States)

    Harari, Colin M; Magagna, Michelle; Bedoya, Mariajose; Lee, Fred T; Lubner, Meghan G; Hinshaw, J Louis; Ziemlewicz, Timothy; Brace, Christopher L

    2016-01-01

    To compare microwave ablation zones created by using sequential or simultaneous power delivery in ex vivo and in vivo liver tissue. All procedures were approved by the institutional animal care and use committee. Microwave ablations were performed in both ex vivo and in vivo liver models with a 2.45-GHz system capable of powering up to three antennas simultaneously. Two- and three-antenna arrays were evaluated in each model. Sequential and simultaneous ablations were created by delivering power (50 W ex vivo, 65 W in vivo) for 5 minutes per antenna (10 and 15 minutes total ablation time for sequential ablations, 5 minutes for simultaneous ablations). Thirty-two ablations were performed in ex vivo bovine livers (eight per group) and 28 in the livers of eight swine in vivo (seven per group). Ablation zone size and circularity metrics were determined from ablations excised postmortem. Mixed effects modeling was used to evaluate the influence of power delivery, number of antennas, and tissue type. On average, ablations created by using the simultaneous power delivery technique were larger than those with the sequential technique (P Simultaneous ablations were also more circular than sequential ablations (P = .0001). Larger and more circular ablations were achieved with three antennas compared with two antennas (P simultaneous power delivery creates larger, more confluent ablations with greater temperatures than those created with sequential power delivery. © RSNA, 2015.

  13. Simultaneous analysis and monitoring of 16 UV filters in cosmetics by high-performance liquid chromatography.

    Science.gov (United States)

    Kim, Dojung; Kim, Sangseop; Kim, Seol-A; Choi, Myoengsin; Kwon, Kyoung-Jin; Kim, Mijeong; Kim, Dong-Sup; Kim, Seung-Hee; Choi, Bo-Kyung

    2012-01-01

    Sixteen UV filters were simultaneously analyzed using the high-performance liquid chromatographic method. They were drometrizole (USAN Drometrizole), 4-methylbenzylidene camphor (USAN Enzacamene), menthyl anthranilate (USAN Menthyl anthranilate), benzophenone-3 (USAN Oxybenzone), benzophenone-8 (USAN Dioxybenzone), butyl methoxydibenzoylmethane (USAN Avobenzone), ethylhexyl triazone (USAN Octyl triazone), octocrylene (USAN Octocrylene), ethylhexyl dimethyl p-aminobenzoic acid (USAN Padimate O), ethylhexyl methoxycinnamate (USAN Octinoxate), p-aminobenzoic acid (USAN Aminobenzoic acid), 2-phenylbenzimidazole-5-sulfonic acid (USAN Ensulizole), isoamyl p-methoxycinnamate (USAN Amiloxate), and recent UV filters such as diethylhexyl butamidotriazone (USAN Iscotrizinol), methylene bis-benzotriazolyl tetramethylbutylphenol (USAN Bisoctrizole), and terephthalylidene dicamphor sulfonic acid (USAN Ecamsule). Separation of the UV filters was carried out in a C(18) column with a gradient of methanol-phosphate buffer, and the UV detection was at 300, 320, or 360 nm without any interference. The limits of detection were between 0.08 and 1.94 μg/ml, and the limits of quantitation were between 0.24 and 5.89 μg/ml. The extracting solvent for the UV filters was methanol, except for ethylhexyl triazone and methylene bis-benzotriazolyl tetramethylbutylphenol, which were prepared with tetrahydrofuran. The recoveries from spiked samples were between 94.90% and 116.54%, depending on the matrixes used. The developed method was applied to 23 sunscreens obtained from local markets, and the results were acceptable to their own criteria and to maximum authorized concentrations. Consequently, these results would provide a simple extracting method and a simultaneous determination for various UV filters, which can improve the quality control process as well as the environmental monitoring of sunscreens.

  14. Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy.

    Science.gov (United States)

    Mishra, Vikas; Gautier, Nicole M; Glasscock, Edward

    2018-01-29

    In epilepsy, seizures can evoke cardiac rhythm disturbances such as heart rate changes, conduction blocks, asystoles, and arrhythmias, which can potentially increase risk of sudden unexpected death in epilepsy (SUDEP). Electroencephalography (EEG) and electrocardiography (ECG) are widely used clinical diagnostic tools to monitor for abnormal brain and cardiac rhythms in patients. Here, a technique to simultaneously record video, EEG, and ECG in mice to measure behavior, brain, and cardiac activities, respectively, is described. The technique described herein utilizes a tethered (i.e., wired) recording configuration in which the implanted electrode on the head of the mouse is hard-wired to the recording equipment. Compared to wireless telemetry recording systems, the tethered arrangement possesses several technical advantages such as a greater possible number of channels for recording EEG or other biopotentials; lower electrode costs; and greater frequency bandwidth (i.e., sampling rate) of recordings. The basics of this technique can also be easily modified to accommodate recording other biosignals, such as electromyography (EMG) or plethysmography for assessment of muscle and respiratory activity, respectively. In addition to describing how to perform the EEG-ECG recordings, we also detail methods to quantify the resulting data for seizures, EEG spectral power, cardiac function, and heart rate variability, which we demonstrate in an example experiment using a mouse with epilepsy due to Kcna1 gene deletion. Video-EEG-ECG monitoring in mouse models of epilepsy or other neurological disease provides a powerful tool to identify dysfunction at the level of the brain, heart, or brain-heart interactions.

  15. Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    Carlo Massaroni

    2017-04-01

    Full Text Available During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fiber Bragg grating (FBG for the simultaneous monitoring of gas relative humidity (RH and temperature, intended to be used for providing feedback to the HWHs’ control. This solution can be implemented using an array of two FBGs having a different center wavelength. Regarding RH monitoring, three sensors have been fabricated by coating an FBG with two different moisture-sensitive and biocompatible materials: the first two sensors were fabricated by coating the grating with a 3 mm × 3 mm layer of agar and agarose; to investigate the influence of the coating thickness to the sensor response, a third sensor was developed with a 5 mm × 5 mm layer of agar. The sensors have been assessed in a wide range of RH (up to 95% during both an ascending and a subsequent descending phase. Only the response of the 3 mm × 3 mm-coated sensors were fast enough to follow the RH changes, showing a mean sensitivity of about 0.14 nm/% (agar-coated and 0.12 nm/% (agarose-coated. The hysteresis error was about <10% in the two sensors. The contribution of temperature changes on these RH sensors was negligible. The temperature measurement was performed by a commercial FBG insensitive to RH changes. The small size of these FBG-based sensors, the use of biocompatible polymers, and the possibility to measure both temperature and RH by using the same fiber optic embedding an array of two FBGs make intriguing the use of this solution for application in the control of HWHs.

  16. Closed-loop surface-related multiple elimination and its application to simultaneous data reconstruction

    NARCIS (Netherlands)

    Lopez Angarita, G.A.; Verschuur, D.J.

    2015-01-01

    Surface-related multiple elimination (SRME) is one of the most commonly used methods for suppressing surface multiples. However, to obtain an accurate surface multiple estimation, dense source and receiver sampling is required. The traditional approach to this problem is performing data

  17. The mathematics of random mutation and natural selection for multiple simultaneous selection pressures and the evolution of antimicrobial drug resistance.

    Science.gov (United States)

    Kleinman, Alan

    2016-12-20

    The random mutation and natural selection phenomenon act in a mathematically predictable behavior, which when understood leads to approaches to reduce and prevent the failure of the use of these selection pressures when treating infections and cancers. The underlying principle to impair the random mutation and natural selection phenomenon is to use combination therapy, which forces the population to evolve to multiple selection pressures simultaneously that invoke the multiplication rule of probabilities simultaneously as well. Recently, it has been seen that combination therapy for the treatment of malaria has failed to prevent the emergence of drug-resistant variants. Using this empirical example and the principles of probability theory, the derivation of the equations describing this treatment failure is carried out. These equations give guidance as to how to use combination therapy for the treatment of cancers and infectious diseases and prevent the emergence of drug resistance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Simultaneous assay of multiple antibiotics in human plasma by LC-MS/MS: importance of optimizing formic acid concentration.

    Science.gov (United States)

    Chen, Feng; Hu, Zhe-Yi; Laizure, S Casey; Hudson, Joanna Q

    2017-03-01

    Optimal dosing of antibiotics in critically ill patients is complicated by the development of resistant organisms requiring treatment with multiple antibiotics and alterations in systemic exposure due to diseases and extracorporeal drug removal. Developing guidelines for optimal antibiotic dosing is an important therapeutic goal requiring robust analytical methods to simultaneously measure multiple antibiotics. An LC-MS/MS assay using protein precipitation for cleanup followed by a 6-min gradient separation was developed to simultaneously determine five antibiotics in human plasma. The precision and accuracy were within the 15% acceptance range. The formic acid concentration was an important determinant of signal intensity, peak shape and matrix effects. The method was designed to be simple and successfully applied to a clinical pharmacokinetic study.

  19. A comparison of approaches for simultaneous inference of fixed effects for multiple outcomes using linear mixed models

    DEFF Research Database (Denmark)

    Jensen, Signe Marie; Ritz, Christian

    2018-01-01

    Longitudinal studies with multiple outcomes often pose challenges for the statistical analysis. A joint model including all outcomes has the advantage of incorporating the simultaneous behavior but is often difficult to fit due to computational challenges. We consider 2 alternative approaches to ......, pairwise fitting shows a larger loss in efficiency than the marginal models approach. Using an alternative to the joint modelling strategy will lead to some but not necessarily a large loss of efficiency for small sample sizes....

  20. Simultaneous monitoring of faecal indicators and harmful algae using an in-situ autonomous sensor.

    Science.gov (United States)

    Yamahara, K M; Demir-Hilton, E; Preston, C M; Marin, R; Pargett, D; Roman, B; Jensen, S; Birch, J M; Boehm, A B; Scholin, C A

    2015-08-01

    Faecal indicator bacteria (FIB) and harmful algal blooms (HABs) threaten the health and the economy of coastal communities worldwide. Emerging automated sampling technologies combined with molecular analytical techniques could enable rapid detection of micro-organisms in-situ, thereby improving resource management and public health decision-making. We evaluated this concept using a robotic device, the Environmental Sample Processor (ESP). The ESP automates in-situ sample collection, nucleic acid extraction and molecular analyses. Here, the ESP measured and reported concentrations of FIB (Enterococcus spp.), a microbial source-tracking marker (human-specific Bacteriodales) and a HAB species (Psuedo-nitzschia spp.) over a 45-day deployment on the Santa Cruz Municipal Wharf (Santa Cruz, CA, USA). Both FIB and HABs were enumerated from single in-situ collected water samples. The in-situ qPCR efficiencies ranged from 86% to 105%, while the limit of quantifications during the deployment was 10 copies reaction(-1) . No differences were observed in the concentrations of enterococci, the human-specific marker in Bacteroidales spp., and P. australis between in-situ collected sample and traditional hand sampling methods (P > 0·05). Analytical results were Internet-accessible within hours of sample collection, demonstrating the feasibility of same-day public notification of current water quality conditions. This study presents the first report of in-situ qPCR enumeration of both faecal indicators and harmful algal species in coastal marine waters. We utilize a robotic device for in-situ quantification of enterococci, the human-specific marker in Bacteriodales and Pseudo-nitzschia spp. from the same water samples collected and processed in-situ. The results demonstrate that rapid, in-situ monitoring can be utilized to identify and quantify multiple health-relevant micro-organisms important in water quality monitoring and that this monitoring can be used to inform same

  1. Simultaneous distribution between the deflection angle and the lateral displacement under the Moliere theory of multiple scattering

    Energy Technology Data Exchange (ETDEWEB)

    Nakatsuka, Takao [Okayama Shoka University, Laboratory of Information Science, Okayama (Japan); Okei, Kazuhide [Kawasaki Medical School, Dept. of Information Sciences, Kurashiki (Japan); Iyono, Atsushi [Okayama university of Science, Dept. of Fundamental Science, Faculty of Science, Okayama (Japan); Bielajew, Alex F. [Univ. of Michigan, Dept. Nuclear Engineering and Radiological Sciences, Ann Arbor, MI (United States)

    2015-12-15

    Simultaneous distribution between the deflection angle and the lateral displacement of fast charged particles traversing through matter is derived by applying numerical inverse Fourier transforms on the Fourier spectral density solved analytically under the Moliere theory of multiple scattering, taking account of ionization loss. Our results show the simultaneous Gaussian distribution at the region of both small deflection angle and lateral displacement, though they show the characteristic contour patterns of probability density specific to the single and the double scatterings at the regions of large deflection angle and/or lateral displacement. The influences of ionization loss on the distribution are also investigated. An exact simultaneous distribution is derived under the fixed energy condition based on a well-known model of screened single scattering, which indicates the limit of validity of the Moliere theory applied to the simultaneous distribution. The simultaneous distribution will be valuable for improving the accuracy and the efficiency of experimental analyses and simulation studies relating to charged particle transports. (orig.)

  2. A novel GMO biosensor for rapid ultrasensitive and simultaneous detection of multiple DNA components in GMO products.

    Science.gov (United States)

    Huang, Lin; Zheng, Lei; Chen, Yinji; Xue, Feng; Cheng, Lin; Adeloju, Samuel B; Chen, Wei

    2015-04-15

    Since the introduction of genetically modified organisms (GMOs), there has been on-going and continuous concern and debates on the commercialization of products derived from GMOs. There is an urgent need for development of highly efficient analytical methods for rapid and high throughput screening of GMOs components, as required for appropriate labeling of GMO-derived foods, as well as for on-site inspection and import/export quarantine. In this study, we describe, for the first time, a multi-labeling based electrochemical biosensor for simultaneous detection of multiple DNA components of GMO products on the same sensing interface. Two-round signal amplification was applied by using both an exonuclease enzyme catalytic reaction and gold nanoparticle-based bio-barcode related strategies, respectively. Simultaneous multiple detections of different DNA components of GMOs were successfully achieved with satisfied sensitivity using this electrochemical biosensor. Furthermore, the robustness and effectiveness of the proposed approach was successfully demonstrated by application to various GMO products, including locally obtained and confirmed commercial GMO seeds and transgenetic plants. The proposed electrochemical biosensor demonstrated unique merits that promise to gain more interest in its use for rapid and on-site simultaneous multiple screening of different components of GMO products. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. [Multiple simultaneous stratigraphy. Results with a 5-plane system for pediatric use].

    Science.gov (United States)

    Iannaccone, G; Capocaccia, P; Boi, A; Calì, M; Del Chierico, G; Morelli, C; Ricci, L

    1988-10-01

    The authors report the results of a five-layer simultaneous multisection tomographic technique to be used in pediatric radiology, based on an appropriately selected series of Trimax rare-earth intensifying screens arranged in progressive speed order. The technique has been so far employed with excellent results in 100 children, especially during IVP, when X-ray examination is very frequently disturbed by ileocolic gas. The many advantages of the technique are emphasized: a) all sections are perfectly parallel and simultaneous, in the same respiratory phase and body position; b) film density is practically identical in all sections; c) there is considerable saving in time, machine consumption, and radiation dose.

  4. COPD Exacerbation Biomarkers Validated Using Multiple Reaction Monitoring Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Janice M Leung

    Full Text Available Acute exacerbations of chronic obstructive pulmonary disease (AECOPD result in considerable morbidity and mortality. However, there are no objective biomarkers to diagnose AECOPD.We used multiple reaction monitoring mass spectrometry to quantify 129 distinct proteins in plasma samples from patients with COPD. This analytical approach was first performed in a biomarker cohort of patients hospitalized with AECOPD (Cohort A, n = 72. Proteins differentially expressed between AECOPD and convalescent states were chosen using a false discovery rate 1.2. Protein selection and classifier building were performed using an elastic net logistic regression model. The performance of the biomarker panel was then tested in two independent AECOPD cohorts (Cohort B, n = 37, and Cohort C, n = 109 using leave-pair-out cross-validation methods.Five proteins were identified distinguishing AECOPD and convalescent states in Cohort A. Biomarker scores derived from this model were significantly higher during AECOPD than in the convalescent state in the discovery cohort (p<0.001. The receiver operating characteristic cross-validation area under the curve (CV-AUC statistic was 0.73 in Cohort A, while in the replication cohorts the CV-AUC was 0.77 for Cohort B and 0.79 for Cohort C.A panel of five biomarkers shows promise in distinguishing AECOPD from convalescence and may provide the basis for a clinical blood test to diagnose AECOPD. Further validation in larger cohorts is necessary for future clinical translation.

  5. Risk evaluation and monitoring in multiple sclerosis therapeutics.

    Science.gov (United States)

    Clanet, Michel C; Wolinsky, Jerry S; Ashton, Raymond J; Hartung, Hans-Peter; Reingold, Stephen C

    2014-09-01

    Risk for multiple sclerosis (MS) disease-modifying therapies (DMT) must be assessed on an ongoing basis. Early concerns regarding the first-approved DMTs for MS have been mitigated, but recently licensed therapies have been linked to possibly greater risks. The objective of this review is to discuss risk assessment in MS therapeutics based on an international workshop and comprehensive literature search and recommend strategies for risk assessment/monitoring. Assessment and perception of therapeutic risks vary between patients, doctors and regulators. Acceptability of risk depends on the magnitude of risk and the demonstrated clinical benefits of any agent. Safety signals must be distinguishable from chance occurrences in a clinical trial and in long-term use of medications. Post-marketing research is crucial for assessing longer-term safety in large patient cohorts. Reporting of adverse events is becoming more proactive, allowing more rapid identification of risks. Communication about therapeutic risks and their relationship to clinical benefit must involve patients in shared decision making. It is difficult to produce a general risk-assessment algorithm for all MS therapies. Specific algorithms are required for each DMT in every treated-patient population. New and evolving risks must be evaluated and communicated rapidly to allow patients and physicians to be well informed and able to share treatment decisions. © The Author(s) 2013.

  6. Everyday multiscreening : How the simultaneous usage of multiple screens affects information processing and advertising effectiveness

    NARCIS (Netherlands)

    Segijn, C.M.

    2017-01-01

    Today, people have access to a variety of screens, such as a television, laptop, smartphone, and tablet. Screen saturation and the convergence of these technologies have led to an increase in combining different screens simultaneously, also known as multiscreening. With so many new devices and

  7. Simultaneous Determination of Binding Constants for Multiple Carbohydrate Hosts in Complex Mixtures

    DEFF Research Database (Denmark)

    Meier, Sebastian; Beeren, Sophie

    2014-01-01

    We describe a simple method for the simultaneous determination of association constants for a guest binding to seven different hosts in a mixture of more than 20 different oligosaccharides. If the binding parameters are known for one component in the mixture, a single NMR titration suffices...

  8. Using Spread Spectrum Transform for Fast and Robust Simultaneous Measurement in Active Sensors with Multiple Emitters

    DEFF Research Database (Denmark)

    Harbo, Anders La-Cour; Stoustrup, Jakob

    2002-01-01

    We present a signal processing algorithm for making robust and simultaneous measurements in an active sensor, which has one or more emitters and a receiver, and which employs some sort of signal processing hardware. Robustness means low sensitivity to time and frequency localized disturbances......-cost active sensors....

  9. GroEL-GroES assisted folding of multiple recombinant proteins simultaneously over-expressed in Escherichia coli.

    Science.gov (United States)

    Goyal, Megha; Chaudhuri, Tapan K

    2015-07-01

    Folding of aggregation prone recombinant proteins through co-expression of chaperonin GroEL and GroES has been a popular practice in the effort to optimize preparation of functional protein in Escherichia coli. Considering the demand for functional recombinant protein products, it is desirable to apply the chaperone assisted protein folding strategy for enhancing the yield of properly folded protein. Toward the same direction, it is also worth attempting folding of multiple recombinant proteins simultaneously over-expressed in E. coli through the assistance of co-expressed GroEL-ES. The genesis of this thinking was originated from the fact that cellular GroEL and GroES assist in the folding of several endogenous proteins expressed in the bacterial cell. Here we present the experimental findings from our study on co-expressed GroEL-GroES assisted folding of simultaneously over-expressed proteins maltodextrin glucosidase (MalZ) and yeast mitochondrial aconitase (mAco). Both proteins mentioned here are relatively larger and aggregation prone, mostly form inclusion bodies, and undergo GroEL-ES assisted folding in E. coli cells during over-expression. It has been reported that the relative yield of properly folded functional forms of MalZ and mAco with the exogenous GroEL-ES assistance were comparable with the results when these proteins were overexpressed alone. This observation is quite promising and highlights the fact that GroEL and GroES can assist in the folding of multiple substrate proteins simultaneously when over-expressed in E. coli. This method might be a potential tool for enhanced production of multiple functional recombinant proteins simultaneously in E. coli. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Multi-target QSPR modeling for simultaneous prediction of multiple gas-phase kinetic rate constants of diverse chemicals

    Science.gov (United States)

    Basant, Nikita; Gupta, Shikha

    2018-03-01

    The reactions of molecular ozone (O3), hydroxyl (•OH) and nitrate (NO3) radicals are among the major pathways of removal of volatile organic compounds (VOCs) in the atmospheric environment. The gas-phase kinetic rate constants (kO3, kOH, kNO3) are thus, important in assessing the ultimate fate and exposure risk of atmospheric VOCs. Experimental data for rate constants are not available for many emerging VOCs and the computational methods reported so far address a single target modeling only. In this study, we have developed a multi-target (mt) QSPR model for simultaneous prediction of multiple kinetic rate constants (kO3, kOH, kNO3) of diverse organic chemicals considering an experimental data set of VOCs for which values of all the three rate constants are available. The mt-QSPR model identified and used five descriptors related to the molecular size, degree of saturation and electron density in a molecule, which were mechanistically interpretable. These descriptors successfully predicted three rate constants simultaneously. The model yielded high correlations (R2 = 0.874-0.924) between the experimental and simultaneously predicted endpoint rate constant (kO3, kOH, kNO3) values in test arrays for all the three systems. The model also passed all the stringent statistical validation tests for external predictivity. The proposed multi-target QSPR model can be successfully used for predicting reactivity of new VOCs simultaneously for their exposure risk assessment.

  11. A Multiple Items EPQ/EOQ Model for a Vendor and Multiple Buyers System with Considering Continuous and Discrete Demand Simultaneously

    Science.gov (United States)

    Jonrinaldi; Rahman, T.; Henmaidi; Wirdianto, E.; Zhang, D. Z.

    2018-03-01

    This paper proposed a mathematical model for multiple items Economic Production and Order Quantity (EPQ/EOQ) with considering continuous and discrete demand simultaneously in a system consisting of a vendor and multiple buyers. This model is used to investigate the optimal production lot size of the vendor and the number of shipments policy of orders to multiple buyers. The model considers the multiple buyers’ holding cost as well as transportation cost, which minimize the total production and inventory costs of the system. The continuous demand from any other customers can be fulfilled anytime by the vendor while the discrete demand from multiple buyers can be fulfilled by the vendor using the multiple delivery policy with a number of shipments of items in the production cycle time. A mathematical model is developed to illustrate the system based on EPQ and EOQ model. Solution procedures are proposed to solve the model using a Mixed Integer Non Linear Programming (MINLP) and algorithm methods. Then, the numerical example is provided to illustrate the system and results are discussed.

  12. Simultaneous navigation of multiple Pareto surfaces, with an application to multicriteria IMRT planning with multiple beam angle configurations.

    Science.gov (United States)

    Craft, David; Monz, Michael

    2010-02-01

    To introduce a method to simultaneously explore a collection of Pareto surfaces. The method will allow radiotherapy treatment planners to interactively explore treatment plans for different beam angle configurations as well as different treatment modalities. The authors assume a convex optimization setting and represent the Pareto surface for each modality or given beam set by a set of discrete points on the surface. Weighted averages of these discrete points produce a continuous representation of each Pareto surface. The authors calculate a set of Pareto surfaces and use linear programming to navigate across the individual surfaces, allowing switches between surfaces. The switches are organized such that the plan profits in the requested way, while trying to keep the change in dose as small as possible. The system is demonstrated on a phantom pancreas IMRT case using 100 different five beam configurations and a multicriteria formulation with six objectives. The system has intuitive behavior and is easy to control. Also, because the underlying linear programs are small, the system is fast enough to offer real-time exploration for the Pareto surfaces of the given beam configurations. The system presented offers a sound starting point for building clinical systems for multicriteria exploration of different modalities and offers a controllable way to explore hundreds of beam angle configurations in IMRT planning, allowing the users to focus their attention on the dose distribution and treatment planning objectives instead of spending excessive time on the technicalities of delivery.

  13. Simultaneous Treatment of Missing Data and Measurement Error in HIV Research Using Multiple Overimputation.

    Science.gov (United States)

    Schomaker, Michael; Hogger, Sara; Johnson, Leigh F; Hoffmann, Christopher J; Bärnighausen, Till; Heumann, Christian

    2015-09-01

    Both CD4 count and viral load in HIV-infected persons are measured with error. There is no clear guidance on how to deal with this measurement error in the presence of missing data. We used multiple overimputation, a method recently developed in the political sciences, to account for both measurement error and missing data in CD4 count and viral load measurements from four South African cohorts of a Southern African HIV cohort collaboration. Our knowledge about the measurement error of ln CD4 and log10 viral load is part of an imputation model that imputes both missing and mismeasured data. In an illustrative example, we estimate the association of CD4 count and viral load with the hazard of death among patients on highly active antiretroviral therapy by means of a Cox model. Simulation studies evaluate the extent to which multiple overimputation is able to reduce bias in survival analyses. Multiple overimputation emphasizes more strongly the influence of having high baseline CD4 counts compared to both a complete case analysis and multiple imputation (hazard ratio for >200 cells/mm vs. <25 cells/mm: 0.21 [95% confidence interval: 0.18, 0.24] vs. 0.38 [0.29, 0.48], and 0.29 [0.25, 0.34], respectively). Similar results are obtained when varying assumptions about measurement error, when using p-splines, and when evaluating time-updated CD4 count in a longitudinal analysis. The estimates of the association with viral load are slightly more attenuated when using multiple imputation instead of multiple overimputation. Our simulation studies suggest that multiple overimputation is able to reduce bias and mean squared error in survival analyses. Multiple overimputation, which can be used with existing software, offers a convenient approach to account for both missing and mismeasured data in HIV research.

  14. Extensive intestinal first-pass metabolism of arctigenin: evidenced by simultaneous monitoring of both parent drug and its major metabolites.

    Science.gov (United States)

    Gao, Qiong; Zhang, Yufeng; Wo, Siukwan; Zuo, Zhong

    2014-03-01

    The current study aims to investigate intestinal absorption and metabolism of arctigenin (AR) through simultaneous monitoring of AR and its major metabolites in rat plasma. An UPLC/MS/MS assay was developed with chromatographic separation of all analytes achieved by a C18 Column (3.9mm×150mm, 3.5μm) and a gradient elution with acetonitrile and 0.1% formic acid within 9min. Sample extraction with acetonitrile was optimized to achieve satisfactory recovery for both AR and its major metabolites. The lower limit of quantification (LLOQ) for all analytes was 25ng/ml. The intra-day and inter-day precision and accuracy of each analyte at LLOQ and three quality control (QC) concentrations (low, middle and high) in rat plasma was within 15.0% RSD and 15.0% bias. The extraction recoveries were within the range of 83.8-94.0% for all analytes. The developed and validated assay was then applied to the absorption study of AR in both Caco-2 cell monolayer model and in situ single-pass rat intestinal perfusion model. High absorption permeability of AR was demonstrated in both models with Papp of (1.76±0.48)×10(-5) (A→B) (Caco-2) and Pblood of (8.6±3.0)×10(-6)cm/s (intestinal perfusion). Extensive first-pass metabolism of AR to arctigenic acid (AA) and arctigenin-4'-O-glucuronide (AG) was identified in rat intestinal perfusion study with Cummins's extraction ratios of 0.458±0.012 and 0.085±0.013, respectively. The current assay method demonstrated to be a practical tool for pharmacokinetics investigation of AR with complicated metabolism pathways and multiple metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Simultaneous heat integration and techno-economic optimization of Organic Rankine Cycle (ORC) for multiple waste heat stream recovery

    International Nuclear Information System (INIS)

    Yu, Haoshui; Eason, John; Biegler, Lorenz T.; Feng, Xiao

    2017-01-01

    In the past decades, the Organic Rankine Cycle (ORC) has become a promising technology for low and medium temperature energy utilization. In refineries, there are usually multiple waste heat streams to be recovered. From a safety and controllability perspective, using an intermedium (hot water) to recover waste heat before releasing heat to the ORC system is more favorable than direct integration. The mass flowrate of the intermediate hot water stream determines the amount of waste heat recovered and the final hot water temperature affects the thermal efficiency of ORC. Both, in turn, exert great influence on the power output. Therefore, the hot water mass flowrate is a critical decision variable for the optimal design of the system. This study develops a model for techno-economic optimization of an ORC with simultaneous heat recovery and capital cost optimization. The ORC is modeled using rigorous thermodynamics with the concept of state points. The task of waste heat recovery using the hot water intermedium is modeled using the Duran-Grossmann model for simultaneous heat integration and process optimization. The combined model determines the optimal design of an ORC that recovers multiple waste heat streams in a large scale background process using an intermediate heat transfer stream. In particular, the model determines the optimal heat recovery approach temperature (HRAT), the utility load of the background process, and the optimal operating conditions of the ORC simultaneously. The effectiveness of this method is demonstrated with a case study that uses a refinery as the background process. Sensitivity of the optimal solution to the parameters (electricity price, utility cost) is quantified in this paper. - Highlights: • A new model for Organic Rankine cycle design optimization is presented. • Process heat integration and ORC are considered simultaneously. • Rigorous equation oriented models of the ORC are used for accurate results. • Impact of working

  17. System health monitoring using multiple-model adaptive estimation techniques

    Science.gov (United States)

    Sifford, Stanley Ryan

    Monitoring system health for fault detection and diagnosis by tracking system parameters concurrently with state estimates is approached using a new multiple-model adaptive estimation (MMAE) method. This novel method is called GRid-based Adaptive Parameter Estimation (GRAPE). GRAPE expands existing MMAE methods by using new techniques to sample the parameter space. GRAPE expands on MMAE with the hypothesis that sample models can be applied and resampled without relying on a predefined set of models. GRAPE is initially implemented in a linear framework using Kalman filter models. A more generalized GRAPE formulation is presented using extended Kalman filter (EKF) models to represent nonlinear systems. GRAPE can handle both time invariant and time varying systems as it is designed to track parameter changes. Two techniques are presented to generate parameter samples for the parallel filter models. The first approach is called selected grid-based stratification (SGBS). SGBS divides the parameter space into equally spaced strata. The second approach uses Latin Hypercube Sampling (LHS) to determine the parameter locations and minimize the total number of required models. LHS is particularly useful when the parameter dimensions grow. Adding more parameters does not require the model count to increase for LHS. Each resample is independent of the prior sample set other than the location of the parameter estimate. SGBS and LHS can be used for both the initial sample and subsequent resamples. Furthermore, resamples are not required to use the same technique. Both techniques are demonstrated for both linear and nonlinear frameworks. The GRAPE framework further formalizes the parameter tracking process through a general approach for nonlinear systems. These additional methods allow GRAPE to either narrow the focus to converged values within a parameter range or expand the range in the appropriate direction to track the parameters outside the current parameter range boundary

  18. The local domain wall position in ferromagnetic thin wires: simultaneous measurement of resistive and transverse voltages at multiple points

    International Nuclear Information System (INIS)

    Hanada, R.; Sugawara, H.; Aoki, Y.; Sato, H.; Shigeto, K.; Shinjo, T.; Ono, T.; Miyajima, H.

    2002-01-01

    We have simultaneously measured the field dependences of voltages at multiple pairs of resistance and transverse voltage probes in ferromagnetic wires (with either magnetic or non-magnetic voltage probes). Both the resistive (through the giant magnetoresistance and anisotropic magnetoresistance) and transverse voltages (through the planar Hall effect) exhibit abrupt jumps, reflecting discrete motion of domain walls or rotations of magnetization. Voltage probes, even if non-magnetic, are found to affect the jump fields depending on the sample conditions. We demonstrate that the specific information on the domain (wall) motion along a thin ferromagnetic wire could be obtained from the jump fields. (author)

  19. Simultaneous quantification of multiple components in rat plasma by UPLC-MS/MS and pharmacokinetic study after oral administration of Huangqi decoction.

    Science.gov (United States)

    Zeng, Jia-Kai; Li, Yuan-Yuan; Wang, Tian-Ming; Zhong, Jie; Wu, Jia-Sheng; Liu, Ping; Zhang, Hua; Ma, Yue-Ming

    2018-05-01

    A rapid, sensitive and accurate UPLC-MS/MS method was developed for the simultaneous quantification of components of Huangqi decoction (HQD), such as calycosin-7-O-β-d-glucoside, calycosin-glucuronide, liquiritin, formononetin-glucuronide, isoliquiritin, liquiritigenin, ononin, calycosin, isoliquiritigenin, formononetin, glycyrrhizic acid, astragaloside IV, cycloastragenol, and glycyrrhetinic acid, in rat plasma. After plasma samples were extracted by protein precipitation, chromatographic separation was performed with a C 18 column, using a gradient of methanol and 0.05% acetic acid containing 4mm ammonium acetate as the mobile phase. Multiple reaction monitoring scanning was performed to quantify the analytes, and the electrospray ion source polarity was switched between positive and negative modes in a single run of 10 min. Method validation showed that specificity, linearity, accuracy, precision, extraction recovery, matrix effect and stability for 14 components met the requirements for their quantitation in biological samples. The established method was successfully applied to the pharmacokinetic study of multiple components in rats after intragastric administration of HQD. The results clarified the pharmacokinetic characteristics of multiple components found in HQD. This research provides useful information for understanding the relation between the chemical components of HQD and their therapeutic effects. Copyright © 2017 John Wiley & Sons, Ltd.

  20. All Set! Evidence of Simultaneous Attentional Control Settings for Multiple Target Colors

    Science.gov (United States)

    Irons, Jessica L.; Folk, Charles L.; Remington, Roger W.

    2012-01-01

    Although models of visual search have often assumed that attention can only be set for a single feature or property at a time, recent studies have suggested that it may be possible to maintain more than one attentional control setting. The aim of the present study was to investigate whether spatial attention could be guided by multiple attentional…

  1. Novel method of simultaneous multiple immunogold localization on resin sections in high resolution scanning electron microscopy

    Czech Academy of Sciences Publication Activity Database

    Nebesářová, Jana; Wandrol, P.; Vancová, Marie

    2016-01-01

    Roč. 12, č. 1 (2016), s. 105-517 ISSN 1549-9634 R&D Projects: GA TA ČR(CZ) TE01020118 Institutional support: RVO:60077344 Keywords : multiple immunolabeling * gold nanoparticles * high resolution SEM * STEM imaging * BSE imaging Subject RIV: EA - Cell Biology Impact factor: 5.720, year: 2016

  2. Characterisation of a cryostat using simultaneous, single-beam multiple-surface laser vibrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kissinger, Thomas; Charrett, Thomas O. H.; James, Stephen W.; Tatam, Ralph P., E-mail: r.p.tatam@cranfield.ac.uk [Engineering Photonics, Cranfield University, Cranfield, MK43 0AL (United Kingdom); Adams, Alvin; Twin, Andrew [Oxford Instruments Nanoscience, Tubney Woods, Abingdon, Oxon, OX13 5QX (United Kingdom)

    2016-06-28

    A novel range-resolved interferometric signal processing technique that uses sinusoidal optical frequency modulation is applied to multi-surface vibrometry, demonstrating simultaneous optical measurements of vibrations on two surfaces using a single, collimated laser beam, with a minimum permissible distance of 3.5 cm between surfaces. The current system, using a cost-effective laser diode and a fibre-coupled, downlead insensitive setup, allows an interferometric fringe rate of up to 180 kHz to be resolved with typical displacement noise levels of 8 pm · Hz{sup −05}. In this paper, the system is applied to vibrometry measurements of a table-top cryostat, with concurrent measurements of the optical widow and the sample holder target inside. This allows the separation of common-mode vibrations of the whole cryostat from differential vibrations between the window and the target, allowing any resonances to be identified.

  3. Simultaneous planning of the project scheduling and material procurement problem under the presence of multiple suppliers

    Science.gov (United States)

    Tabrizi, Babak H.; Ghaderi, Seyed Farid

    2016-09-01

    Simultaneous planning of project scheduling and material procurement can improve the project execution costs. Hence, the issue has been addressed here by a mixed-integer programming model. The proposed model facilitates the procurement decisions by accounting for a number of suppliers offering a distinctive discount formula from which to purchase the required materials. It is aimed at developing schedules with the best net present value regarding the obtained benefit and costs of the project execution. A genetic algorithm is applied to deal with the problem, in addition to a modified version equipped with a variable neighbourhood search. The underlying factors of the solution methods are calibrated by the Taguchi method to obtain robust solutions. The performance of the aforementioned methods is compared for different problem sizes, in which the utilized local search proved efficient. Finally, a sensitivity analysis is carried out to check the effect of inflation on the objective function value.

  4. A semiconductor metasurface with multiple functionalities: A polarizing beam splitter with simultaneous focusing ability

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Hyung; Jin Jung, Myoung; Ho Song, Seok, E-mail: shsong@hanyang.ac.kr [Department of Physics, Hanyang University, Seoul (Korea, Republic of); Woong Yoon, Jae; Magnusson, Robert [Department of Electrical Engineering, University of Texas–Arlington, Arlington, Texas 76019 (United States); Kyun Hong, Jong [Department of Electrical Engineering, Hanyang University, Seoul (Korea, Republic of)

    2014-06-09

    We propose a semiconductor metasurface that simultaneously performs two independent functions: focusing and polarization filtering. The wavefronts of the reflected and transmitted light distributions are precisely manipulated by spatial parametric variation of a subwavelength thin-film Si grating, which inherently possesses polarization filtering properties. We design a 12-μm-wide metasurface containing only nineteen Si grating ridges. Under a 10-μm-wide unpolarized Gaussian beam incidence at wavelength of 1.55 μm, the resulting device shows promising theoretical performance with high power efficiency exceeding 80% and polarization extinction ratio of ∼10 dB with focal spot diameters near 1–2 μm.

  5. Simultaneous and rapid determination of multiple component concentrations in a Kraft liquor process stream

    Science.gov (United States)

    Li, Jian [Marietta, GA; Chai, Xin Sheng [Atlanta, GA; Zhu, Junyoung [Marietta, GA

    2008-06-24

    The present invention is a rapid method of determining the concentration of the major components in a chemical stream. The present invention is also a simple, low cost, device of determining the in-situ concentration of the major components in a chemical stream. In particular, the present invention provides a useful method for simultaneously determining the concentrations of sodium hydroxide, sodium sulfide and sodium carbonate in aqueous kraft pulping liquors through use of an attenuated total reflectance (ATR) tunnel flow cell or optical probe capable of producing a ultraviolet absorbency spectrum over a wavelength of 190 to 300 nm. In addition, the present invention eliminates the need for manual sampling and dilution previously required to generate analyzable samples. The inventive method can be used in Kraft pulping operations to control white liquor causticizing efficiency, sulfate reduction efficiency in green liquor, oxidation efficiency for oxidized white liquor and the active and effective alkali charge to kraft pulping operations.

  6. Simultaneous qubit-loss-free fusion of three multiple W states

    Science.gov (United States)

    Wang, Meiyu; Hao, Quanzhi; Yan, Fengli; Gao, Ting

    2018-05-01

    Qubit-loss-free fusion for two W states introduced by Li K et al (2016 Phys. Rev. A 94 062315) clearly increases the final size of the obtained W state and greatly reduces the number of fusion steps to achieve a W state of a target size. Motivated by this idea, we propose a qubit-loss-free fusion scheme for fusing three polarization entangled W states simultaneously. The elements of a two-outcome positive-operator valued measurement and the appropriate joint unitary operation for realizing a positive-operator valued measurement measurement are given. As an example, with the assistance of weak cross-Kerr nonlinearities, an optical setup for fusing three W states is proposed. We analyze the success probability of the scheme and the resource cost of the present scheme, as compared to previous work.

  7. EasyCloneMulti: A Set of Vectors for Simultaneous and Multiple Genomic Integrations in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Maury, Jerome; Germann, Susanne Manuela; Jacobsen, Simo Abdessamad

    2016-01-01

    Saccharomyces cerevisiae is widely used in the biotechnology industry for production of ethanol, recombinant proteins, food ingredients and other chemicals. In order to generate highly producing and stable strains, genome integration of genes encoding metabolic pathway enzymes is the preferred...... of integrative vectors, EasyCloneMulti, that enables multiple and simultaneous integration of genes in S. cerevisiae. By creating vector backbones that combine consensus sequences that aim at targeting subsets of Ty sequences and a quickly degrading selective marker, integrations at multiple genomic loci...... and a range of expression levels were obtained, as assessed with the green fluorescent protein (GFP) reporter system. The EasyCloneMulti vector set was applied to balance the expression of the rate-controlling step in the β-alanine pathway for biosynthesis of 3-hydroxypropionic acid (3HP). The best 3HP...

  8. Simultaneous inhibition of multiple oncogenic miRNAs by a multi-potent microRNA sponge.

    Science.gov (United States)

    Jung, Jaeyun; Yeom, Chanjoo; Choi, Yeon-Sook; Kim, Sinae; Lee, EunJi; Park, Min Ji; Kang, Sang Wook; Kim, Sung Bae; Chang, Suhwan

    2015-08-21

    The roles of oncogenic miRNAs are widely recognized in many cancers. Inhibition of single miRNA using antagomiR can efficiently knock-down a specific miRNA. However, the effect is transient and often results in subtle phenotype, as there are other miRNAs contribute to tumorigenesis. Here we report a multi-potent miRNA sponge inhibiting multiple miRNAs simultaneously. As a model system, we targeted miR-21, miR-155 and miR-221/222, known as oncogenic miRNAs in multiple tumors including breast and pancreatic cancers. To achieve efficient knockdown, we generated perfect and bulged-matched miRNA binding sites (MBS) and introduced multiple copies of MBS, ranging from one to five, in the multi-potent miRNA sponge. Luciferase reporter assay showed the multi-potent miRNA sponge efficiently inhibited 4 miRNAs in breast and pancreatic cancer cells. Furthermore, a stable and inducible version of the multi-potent miRNA sponge cell line showed the miRNA sponge efficiently reduces the level of 4 target miRNAs and increase target protein level of these oncogenic miRNAs. Finally, we showed the miRNA sponge sensitize cells to cancer drug and attenuate cell migratory activity. Altogether, our study demonstrates the multi-potent miRNA sponge is a useful tool to examine the functional impact of simultaneous inhibition of multiple miRNAs and proposes a therapeutic potential.

  9. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  10. Matrix approach to the simultaneous detection of multiple potato pathogens by real-time PCR.

    Science.gov (United States)

    Nikitin, M M; Statsyuk, N V; Frantsuzov, P A; Dzhavakhiya, V G; Golikov, A G

    2018-03-01

    Create a method for highly sensitive, selective, rapid and easy-to-use detection and identification of economically significant potato pathogens, including viruses, bacteria and oomycetes, be it single pathogen, or a range of various pathogens occurring simultaneously. Test-systems for real-time PCR, operating in the unified amplification regime, have been developed for Phytophthora infestans, Pectobacterium atrosepticum, Dickeya dianthicola, Dickeya solani, Ralstonia solanacearum, Pectobacterium carotovorum, Clavibacter michiganensis subsp. sepedonicus, potato viruses Y (ordinary and necrotic forms as well as indiscriminative test system, detecting all forms), A, X, S, M, potato leaf roll virus, potato mop top virus and potato spindle tuber viroid. The test-systems (including polymerase and revertase) were immobilized and lyophilized in miniature microreactors (1·2 μl) on silicon DNA/RNA microarrays (micromatrices) to be used with a mobile AriaDNA ® amplifier. Preloaded 30-reaction micromatrices having shelf life of 3 and 6 months (for RNA- and DNA-based pathogens, respectively) at room temperature with no special conditions were successfully tested on both reference and field samples in comparison with traditional ELISA and microbiological methods, showing perfect performance and sensitivity (1 pg). The accurate, rapid and user-friendly diagnostic system in a micromatrix format may significantly contribute to pathogen screening and phytopathological studies. © 2018 The Authors. Journal of Applied Microbiology published by John Wiley & Sons Ltd on behalf of The Society for Applied Microbiology.

  11. Simultaneous analysis of multiple neurotransmitters by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Tufi, Sara; Lamoree, Marja; de Boer, Jacob; Leonards, Pim

    2015-05-22

    Neurotransmitters are endogenous metabolites that allow the signal transmission across neuronal synapses. Their biological role is crucial for many physiological functions and their levels can be changed by several diseases. Because of their high polarity, hydrophilic interaction liquid chromatography (HILIC) is a promising tool for neurotransmitter analysis. Due to the large number of HILIC stationary phases available, an evaluation of the column performances and retention behaviors has been performed on five different commercial HILIC packing materials (silica, amino, amide and two zwitterionic stationary phases). Several parameters like the linear correlation between retention and the distribution coefficient (logD), the separation factor k and the column resolution Rs have been investigated and the column performances have been visualized with a heat map and hierarchical clustering analysis. An optimized and validated HILIC-MS/MS method based on the ZIC-cHILIC column is proposed for the simultaneous detection and quantification of twenty compounds consisting of neurotransmitters, precursors and metabolites: 3-methoxytyramine (3-MT), 5-hydroxyindoleacetic acid (5-HIAA), 5-hydroxy-L-tripthophan, acetylcholine, choline, L-3,4-dihydroxyphenylalanine (L-DOPA), dopamine, epinephrine, γ-aminobutyric acid (GABA), glutamate, glutamine, histamine, histidine, L-tryptophan, L-tyrosine, norepinephrine, normetanephrine, phenylalanine, serotonin and tyramine. The method was applied to neuronal metabolite profiling of the central nervous system of the freshwater snail Lymnaea stagnalis. This method is suitable to explore neuronal metabolism and its alteration in different biological matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Evaluation of the aniline chemical oxidation process using multiple simultaneous electrochemical responses

    International Nuclear Information System (INIS)

    Cristovan, Fernando H.; Lemos, Sherlan G.; Santos, Janaina S.; Trivinho-Strixino, Francisco; Pereira, Ernesto C.; Mattoso, Luiz H.C.; Kulkarni, Rashmi; Manohar, Sanjeev K.

    2010-01-01

    In this paper we show the simultaneous evaluation of the electrochemical impedance, the open circuit potential and the mass variation of the polyaniline deposited on a metal substrate during chemical oxidation of aniline. We detected that the final properties of the polymer could be practically defined after the inflection point of the potential profile. Considering a series connection of R and C, impedance Z was decomposed into the resistive and capacitive components. The resistivity and permittivity show a slight change after the inflection point in the potential profile. Impedance data and mass changes during synthesis also contributed to a better definition of the induction period. We described the system as whole, which relates to an electronic transport and to an electronic charge storage process. Although very simple, this model helps us to interpret and correlate different techniques to explain the results. In addition, we demonstrated that the in situ evaluation of the parameters described above offers new insights on the chemical synthesis mechanism of polyaniline.

  13. 3D Simulation of Multiple Simultaneous Hydraulic Fractures with Different Initial Lengths in Rock

    Science.gov (United States)

    Tang, X.; Rayudu, N. M.; Singh, G.

    2017-12-01

    Hydraulic fracturing is widely used technique for extracting shale gas. During this process, fractures with various initial lengths are induced in rock mass with hydraulic pressure. Understanding the mechanism of propagation and interaction between these induced hydraulic cracks is critical for optimizing the fracking process. In this work, numerical results are presented for investigating the effect of in-situ parameters and fluid properties on growth and interaction of multi simultaneous hydraulic fractures. A fully coupled 3D fracture simulator, TOUGH- GFEM is used for simulating the effect of different vital parameters, including in-situ stress, initial fracture length, fracture spacing, fluid viscosity and flow rate on induced hydraulic fractures growth. This TOUGH-GFEM simulator is based on 3D finite volume method (FVM) and partition of unity element method (PUM). Displacement correlation method (DCM) is used for calculating multi - mode (Mode I, II, III) stress intensity factors. Maximum principal stress criteria is used for crack propagation. Key words: hydraulic fracturing, TOUGH, partition of unity element method , displacement correlation method, 3D fracturing simulator

  14. Model-based monitoring of rotors with multiple coexisting faults

    International Nuclear Information System (INIS)

    Rossner, Markus

    2015-01-01

    Monitoring systems are applied to many rotors, but only few monitoring systems can separate coexisting errors and identify their quantity. This research project solves this problem using a combination of signal-based and model-based monitoring. The signal-based part performs a pre-selection of possible errors; these errors are further separated with model-based methods. This approach is demonstrated for the errors unbalance, bow, stator-fixed misalignment, rotor-fixed misalignment and roundness errors. For the model-based part, unambiguous error definitions and models are set up. The Ritz approach reduces the model order and therefore speeds up the diagnosis. Identification algorithms are developed for the different rotor faults. Hereto, reliable damage indicators and proper sub steps of the diagnosis have to be defined. For several monitoring problems, measuring both deflection and bearing force is very useful. The monitoring system is verified by experiments on an academic rotor test rig. The interpretation of the measurements requires much knowledge concerning the dynamics of the rotor. Due to the model-based approach, the system can separate errors with similar signal patterns and identify bow and roundness error online at operation speed. [de

  15. Representation of Students in Solving Simultaneous Linear Equation Problems Based on Multiple Intelligence

    Science.gov (United States)

    Yanti, Y. R.; Amin, S. M.; Sulaiman, R.

    2018-01-01

    This study described representation of students who have musical, logical-mathematic and naturalist intelligence in solving a problem. Subjects were selected on the basis of multiple intelligence tests (TPM) consists of 108 statements, with 102 statements adopted from Chislet and Chapman and 6 statements equal to eksistensial intelligences. Data were analyzed based on problem-solving tests (TPM) and interviewing. See the validity of the data then problem-solving tests (TPM) and interviewing is given twice with an analyzed using the representation indikator and the problem solving step. The results showed that: the stage of presenting information known, stage of devising a plan, and stage of carrying out the plan those three subjects were using same form of representation. While he stage of presenting information asked and stage of looking back, subject of logical-mathematic was using different forms of representation with subjects of musical and naturalist intelligence. From this research is expected to provide input to the teacher in determining the learning strategy that will be used by considering the representation of students with the basis of multiple intelligences.

  16. Simultaneous Binding of Multiple EF-Tu Copies to Translating Ribosomes in Live Escherichia coli.

    Science.gov (United States)

    Mustafi, Mainak; Weisshaar, James C

    2018-01-16

    In bacteria, elongation factor Tu is a translational cofactor that forms ternary complexes with aminoacyl-tRNA (aa-tRNA) and GTP. Binding of a ternary complex to one of four flexible L7/L12 units on the ribosome tethers a charged tRNA in close proximity to the ribosomal A site. Two sequential tests for a match between the aa-tRNA anticodon and the current mRNA codon then follow. Because one elongation cycle can occur in as little as 50 ms and the vast majority of aa-tRNA copies are not cognate with the current mRNA codon, this testing must occur rapidly. We present a single-molecule localization and tracking study of fluorescently labeled EF-Tu in live Escherichia coli Imaging at 2 ms/frame distinguishes 60% slowly diffusing EF-Tu copies (assigned as transiently bound to translating ribosome) from 40% rapidly diffusing copies (assigned as a mixture of free ternary complexes and free EF-Tu). Combining these percentages with copy number estimates, we infer that the four L7/L12 sites are essentially saturated with ternary complexes in vivo. The results corroborate an earlier inference that all four sites can simultaneously tether ternary complexes near the A site, creating a high local concentration that may greatly enhance the rate of testing of aa-tRNAs. Our data and a combinatorial argument both suggest that the initial recognition test for a codon-anticodon match occurs in less than 1 to 2 ms per aa-tRNA copy. The results refute a recent study (A. Plochowietz, I. Farrell, Z. Smilansky, B. S. Cooperman, and A. N. Kapanidis, Nucleic Acids Res 45:926-937, 2016, https://doi.org/10.1093/nar/gkw787) of tRNA diffusion in E. coli that inferred that aa-tRNAs arrive at the ribosomal A site as bare monomers, not as ternary complexes. IMPORTANCE Ribosomes catalyze translation of the mRNA codon sequence into the corresponding sequence of amino acids within the nascent polypeptide chain. Polypeptide elongation can be as fast as 50 ms per added amino acid. Each amino acid

  17. A Wearable EEG-HEG-HRV Multimodal System With Simultaneous Monitoring of tES for Mental Health Management.

    Science.gov (United States)

    Ha, Unsoo; Lee, Yongsu; Kim, Hyunki; Roh, Taehwan; Bae, Joonsung; Kim, Changhyeon; Yoo, Hoi-Jun

    2015-12-01

    A multimodal mental management system in the shape of the wearable headband and earplugs is proposed to monitor electroencephalography (EEG), hemoencephalography (HEG) and heart rate variability (HRV) for accurate mental health monitoring. It enables simultaneous transcranial electrical stimulation (tES) together with real-time monitoring. The total weight of the proposed system is less than 200 g. The multi-loop low-noise amplifier (MLLNA) achieves over 130 dB CMRR for EEG sensing and the capacitive correlated-double sampling transimpedance amplifier (CCTIA) has low-noise characteristics for HEG and HRV sensing. Measured three-physiology domains such as neural, vascular and autonomic domain signals are combined with canonical correlation analysis (CCA) and temporal kernel canonical correlation analysis (tkCCA) algorithm to find the neural-vascular-autonomic coupling. It supports highly accurate classification with the 19% maximum improvement with multimodal monitoring. For the multi-channel stimulation functionality, after-effects maximization monitoring and sympathetic nerve disorder monitoring, the stimulator is designed as reconfigurable. The 3.37 × 2.25 mm(2) chip has 2-channel EEG sensor front-end, 2-channel NIRS sensor front-end, NIRS current driver to drive dual-wavelength VCSEL and 6-b DAC current source for tES mode. It dissipates 24 mW with 2 mA stimulation current and 5 mA NIRS driver current.

  18. Preliminary data for the 20 May 1974, simultaneous evaluation of remote sensors experiment. [water pollution monitoring

    Science.gov (United States)

    Johnson, R. W.; Batten, C. E.; Bowker, D. E.; Bressette, W. E.; Grew, G. W.

    1975-01-01

    Several remote sensors were simultaneously used to collect data over the tidal James River from Hopewell to Norfolk, Virginia. Sensors evaluated included the Multichannel-Ocean Color Sensor, multispectral scanners, and multispectral photography. Ground truth measurements and remotely sensed data are given. Preliminary analysis indicates that suspended sediment and concentrated industrial effluent are observable from all sensors.

  19. Simultaneous and quantitative monitoring of co-cultured Pseudomonas aeruginosa and Staphylococcus aureus with antibiotics on a diffusometric platform

    Science.gov (United States)

    Chung, Chih-Yao; Wang, Jhih-Cheng; Chuang, Han-Sheng

    2017-04-01

    Successful treatments against bacterial infections depend on antimicrobial susceptibility testing (AST). However, conventional AST requires more than 24 h to obtain an outcome, thereby contributing to high patient mortality. An antibiotic therapy based on experiences is therefore necessary for saving lives and escalating the emergence of multidrug-resistant pathogens. Accordingly, a fast and effective drug screen is necessary for the appropriate administration of antibiotics. The mixed pathogenic nature of infectious diseases emphasizes the need to develop an assay system for polymicrobial infections. On this basis, we present a novel technique for simultaneous and quantitative monitoring of co-cultured microorganisms by coupling optical diffusometry with bead-based immunoassays. This simple integration simultaneously achieves a rapid AST analysis for two pathogens. Triple color particles were simultaneously recorded and subsequently analyzed by functionalizing different fluorescent color particles with dissimilar pathogen-specific antibodies. Results suggested that the effect of the antibiotic, gentamicin, on co-cultured Pseudomonas aeruginosa and Staphylococcus aureus was effectively distinguished by the proposed technique. This study revealed a multiplexed and time-saving (within 2 h) platform with a small sample volume (~0.5 μL) and a low initial bacterial count (50 CFU per droplet, ~105 CFU/mL) for continuously monitoring the growth of co-cultured microorganisms. This technique provides insights into timely therapies against polymicrobial diseases in the near future.

  20. Extreme Value Theory Approach to Simultaneous Monitoring and Thresholding of Multiple Risk Indicators

    NARCIS (Netherlands)

    Einmahl, J.H.J.; Li, J.; Liu, R.Y.

    2006-01-01

    Risk assessments often encounter extreme settings with very few or no occurrences in reality.Inferences about risk indicators in such settings face the problem of insufficient data.Extreme value theory is particularly well suited for handling this type of problems.This paper uses a multivariate

  1. Monitoring the Simultaneous Presentation of Multiple Spatialized Speech Signals in the Free Field

    National Research Council Canada - National Science Library

    Nelson, W. T; Bolia, Robert S; Ericson, Mark A; McKinley, Richard L

    1998-01-01

    .... Factorial combinations of three variables, including the number of localized speech signals, the location of the speech signals along the horizontal plane, and the sex of the talker were employed...

  2. Trade-off between multiple constraints enables simultaneous formation of modules and hubs in neural systems.

    Directory of Open Access Journals (Sweden)

    Yuhan Chen

    Full Text Available The formation of the complex network architecture of neural systems is subject to multiple structural and functional constraints. Two obvious but apparently contradictory constraints are low wiring cost and high processing efficiency, characterized by short overall wiring length and a small average number of processing steps, respectively. Growing evidence shows that neural networks are results from a trade-off between physical cost and functional value of the topology. However, the relationship between these competing constraints and complex topology is not well understood quantitatively. We explored this relationship systematically by reconstructing two known neural networks, Macaque cortical connectivity and C. elegans neuronal connections, from combinatory optimization of wiring cost and processing efficiency constraints, using a control parameter α, and comparing the reconstructed networks to the real networks. We found that in both neural systems, the reconstructed networks derived from the two constraints can reveal some important relations between the spatial layout of nodes and the topological connectivity, and match several properties of the real networks. The reconstructed and real networks had a similar modular organization in a broad range of α, resulting from spatial clustering of network nodes. Hubs emerged due to the competition of the two constraints, and their positions were close to, and partly coincided, with the real hubs in a range of α values. The degree of nodes was correlated with the density of nodes in their spatial neighborhood in both reconstructed and real networks. Generally, the rebuilt network matched a significant portion of real links, especially short-distant ones. These findings provide clear evidence to support the hypothesis of trade-off between multiple constraints on brain networks. The two constraints of wiring cost and processing efficiency, however, cannot explain all salient features in the real

  3. Synergies of multiple remote sensing data sources for REDD+ monitoring

    NARCIS (Netherlands)

    Sy, de V.; Herold, M.; Achard, F.; Asner, G.P.; Held, A.; Kellndorfer, J.; Verbesselt, J.

    2012-01-01

    Remote sensing technologies can provide objective, practical and cost-effective solutions for developing and maintaining REDD+ monitoring systems. This paper reviews the potential and status of available remote sensing data sources with a focus on different forest information products and synergies

  4. Simultaneous analysis of multiple Mycobacterium tuberculosis knockdown mutants in vitro and in vivo.

    Directory of Open Access Journals (Sweden)

    Antje Blumenthal

    2010-12-01

    Full Text Available Mycobacterium tuberculosis (Mtb represents one of the most persistent bacterial threats to human health and new drugs are needed to limit its impact. Conditional knockdown mutants can help validate new drug targets, but the analysis of individual mutants is laborious and time consuming. Here, we describe quantitative DNA tags (qTags and their use to simultaneously analyze conditional Mtb knockdown mutants that allowed silencing the glyoxylate and methylcitrate cycles (via depletion of isocitrate lyase, ICL, the serine protease Rv3671c, and the core subunits of the mycobacterial proteasome, PrcB and PrcA. The impact of gene silencing in multi-strain cultures was determined by measuring the relative abundance of mutant-specific qTags with real-time PCR. This achieved accurate quantification over a broad range of qTag abundances and depletion of ICL, Rv3671c, or PrcBA resulted in the expected impairment of growth of Mtb with butyrate as the primary carbon source, survival during oxidative stress, acid stress and starvation. The impact of depleting ICL, Rv3671c, or PrcBA in multi-strain mouse infections was analyzed with two approaches. We first measured the relative abundance of mutant-specific qTags in total chromosomal DNA isolated from bacteria that were recovered from infected lungs on agar plates. We then developed a two-step amplification procedure, which allowed us to measure the abundances of individual mutants directly in infected lung tissue. Both strategies confirmed that inactivation of Rv3671c and PrcBA severely reduced persistence of Mtb in mice. The multi-strain infections furthermore suggested that silencing ICL not only prevented growth of Mtb during acute infections but also prevented survival of Mtb during chronic infections. Analyses of the ICL knockdown mutant in single-strain infections confirmed this and demonstrated that silencing of ICL during chronic infections impaired persistence of Mtb to the extent that the pathogen

  5. SATe-II: very fast and accurate simultaneous estimation of multiple sequence alignments and phylogenetic trees.

    Science.gov (United States)

    Liu, Kevin; Warnow, Tandy J; Holder, Mark T; Nelesen, Serita M; Yu, Jiaye; Stamatakis, Alexandros P; Linder, C Randal

    2012-01-01

    Highly accurate estimation of phylogenetic trees for large data sets is difficult, in part because multiple sequence alignments must be accurate for phylogeny estimation methods to be accurate. Coestimation of alignments and trees has been attempted but currently only SATé estimates reasonably accurate trees and alignments for large data sets in practical time frames (Liu K., Raghavan S., Nelesen S., Linder C.R., Warnow T. 2009b. Rapid and accurate large-scale coestimation of sequence alignments and phylogenetic trees. Science. 324:1561-1564). Here, we present a modification to the original SATé algorithm that improves upon SATé (which we now call SATé-I) in terms of speed and of phylogenetic and alignment accuracy. SATé-II uses a different divide-and-conquer strategy than SATé-I and so produces smaller more closely related subsets than SATé-I; as a result, SATé-II produces more accurate alignments and trees, can analyze larger data sets, and runs more efficiently than SATé-I. Generally, SATé is a metamethod that takes an existing multiple sequence alignment method as an input parameter and boosts the quality of that alignment method. SATé-II-boosted alignment methods are significantly more accurate than their unboosted versions, and trees based upon these improved alignments are more accurate than trees based upon the original alignments. Because SATé-I used maximum likelihood (ML) methods that treat gaps as missing data to estimate trees and because we found a correlation between the quality of tree/alignment pairs and ML scores, we explored the degree to which SATé's performance depends on using ML with gaps treated as missing data to determine the best tree/alignment pair. We present two lines of evidence that using ML with gaps treated as missing data to optimize the alignment and tree produces very poor results. First, we show that the optimization problem where a set of unaligned DNA sequences is given and the output is the tree and alignment of

  6. Simultaneous imaging of multiple neurotransmitters and neuroactive substances in the brain by desorption electrospray ionization mass spectrometry.

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Strittmatter, Nicole; Nilsson, Anna; Källback, Patrik; Alvarsson, Alexandra; Zhang, Xiaoqun; Vallianatou, Theodosia; Svenningsson, Per; Goodwin, Richard J A; Andren, Per E

    2016-08-01

    With neurological processes involving multiple neurotransmitters and neuromodulators, it is important to have the ability to directly map and quantify multiple signaling molecules simultaneously in a single analysis. By utilizing a molecular-specific approach, namely desorption electrospray ionization mass spectrometry imaging (DESI-MSI), we demonstrated that the technique can be used to image multiple neurotransmitters and their metabolites (dopamine, dihydroxyphenylacetic acid, 3-methoxytyramine, serotonin, glutamate, glutamine, aspartate, γ-aminobutyric acid, adenosine) as well as neuroactive drugs (amphetamine, sibutramine, fluvoxamine) and drug metabolites in situ directly in brain tissue sections. The use of both positive and negative ionization modes increased the number of identified molecular targets. Chemical derivatization by charge-tagging the primary amines of molecules significantly increased the sensitivity, enabling the detection of low abundant neurotransmitters and other neuroactive substances previously undetectable by MSI. The sensitivity of the imaging approach of neurochemicals has a great potential in many diverse applications in fields such as neuroscience, pharmacology, drug discovery, neurochemistry, and medicine. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Luo, Haoze; Iannuzzo, Francesco

    2017-01-01

    the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal......-Oxide-Semiconductor-Field-Effect Transistors (MOSFETs), it is shown that there are opposing trends in the evolution of the on-state resistances of both the bond-wires and the MOSFET die. In summary, after 50,000 temperature cycles, the resistance of the bond-wires increased by up to 2 mΩ, while the on-state resistance of the MOSFET dies...... decreased by approximately 1 mΩ. The conventional failure precursor (monitoring a single forward voltage) cannot distinguish between semiconductor die or bond-wire degradation. Therefore, the ability to monitor both these parameters due to the presence of an auxiliary-source terminal can provide more...

  8. [Simultaneous determination of multiple elements in airborne particulate samples by X-ray fluorescence spectrometry].

    Science.gov (United States)

    Takada, T; Hitosugi, M; Kadowaki, T; Kudo, M

    1983-07-01

    An energy dispersive X-ray fluorescence spectrometer (EDX) has been applied to determine multielements in the workplace air. The standards for X-ray fluorescence analysis were prepared by the chelate precipitation method on polyvinyl chloride (PVC) membrane filter. And, the specimens were prepared to deposit various metal compounds of different chemical forms by the suspension method on PVC membrane filter, and they were determined with EDX and atomic absorption spectrometer (AAS). The results obtained were as follows. Though there is a difference by each element, an amount less than 3 microgram/cm2 per unit area makes it possible to undergo multielement analysis, that is, is has no influence on fine particle effect (particle size; under 5 microns). Then, effects of the X-ray intensity by different chemical forms are negligible. At the presence the neighboring element and other elements this technique showed greater precision by carrying out on corrective treatment, etc. The coefficient of variation of this technique was in the range of 2.5-6.5% at DDTC-Cu of 0.5-5.0 micrograms/cm2, with the limit of detection for As : 0.002 microgram/cm2, Zn : 0.003 microgram/cm2, Pb : 0.003 microgram/cm2, Cu : 0.004 microgram/cm2, Ni : 0.003 microgram/cm2, Fe : 0.005 microgram/cm2, Mn : 0.008 microgram/cm2, Cr : 0.013 microgram/cm2, respectively. Aerosols collected at the workplace were analyzed with EDX and AAS, and the obtained results showed good agreement with such regression line as y = 1.04 chi + 0.04, the coefficient of correlation being r = 0.995. From these results, this technique was found to be a very excellent method for monitoring of multielements in the workplace air.

  9. Ca analysis: an Excel based program for the analysis of intracellular calcium transients including multiple, simultaneous regression analysis.

    Science.gov (United States)

    Greensmith, David J

    2014-01-01

    Here I present an Excel based program for the analysis of intracellular Ca transients recorded using fluorescent indicators. The program can perform all the necessary steps which convert recorded raw voltage changes into meaningful physiological information. The program performs two fundamental processes. (1) It can prepare the raw signal by several methods. (2) It can then be used to analyze the prepared data to provide information such as absolute intracellular Ca levels. Also, the rates of change of Ca can be measured using multiple, simultaneous regression analysis. I demonstrate that this program performs equally well as commercially available software, but has numerous advantages, namely creating a simplified, self-contained analysis workflow. Copyright © 2013 The Author. Published by Elsevier Ireland Ltd.. All rights reserved.

  10. Ca analysis: An Excel based program for the analysis of intracellular calcium transients including multiple, simultaneous regression analysis☆

    Science.gov (United States)

    Greensmith, David J.

    2014-01-01

    Here I present an Excel based program for the analysis of intracellular Ca transients recorded using fluorescent indicators. The program can perform all the necessary steps which convert recorded raw voltage changes into meaningful physiological information. The program performs two fundamental processes. (1) It can prepare the raw signal by several methods. (2) It can then be used to analyze the prepared data to provide information such as absolute intracellular Ca levels. Also, the rates of change of Ca can be measured using multiple, simultaneous regression analysis. I demonstrate that this program performs equally well as commercially available software, but has numerous advantages, namely creating a simplified, self-contained analysis workflow. PMID:24125908

  11. Probabilistic atlas-guided eigen-organ method for simultaneous bounding box estimation of multiple organs in volumetric CT images

    International Nuclear Information System (INIS)

    Yao, Cong; Wada, Takashige; Shimizu, Akinobu; Kobatake, Hidefumi; Nawano, Shigeru

    2006-01-01

    We propose an approach for the simultaneous bounding box estimation of multiple organs in volumetric CT images. Local eigen-organ spaces are constructed for different types of training organs, and a global eigen-space, which describes the spatial relationships between the organs, is also constructed. Each volume of interest in the abdominal CT image is projected into the local eigen-organ spaces, and several candidate locations are determined. The final selection of the organ locations is made by projecting the set of candidate locations into the global eigen-space. A probabilistic atlas of organs is used to eliminate locations with low probability and to guide the selection of candidate locations. Evaluation by the leave-one-out method using 10 volumetric abdominal CT images showed that the proposed method provided an average accuracy of 80.38% for 11 different organ types. (author)

  12. Reverse Transcription Polymerase Chain Reaction-based System for Simultaneous Detection of Multiple Lily-infecting Viruses

    Directory of Open Access Journals (Sweden)

    Ji Yeon Kwon

    2013-09-01

    Full Text Available A detection system based on a multiplex reverse transcription (RT polymerase chain reaction (PCR was developed to simultaneously identify multiple viruses in the lily plant. The most common viruses infecting lily plants are the cucumber mosaic virus (CMV, lily mottle virus (LMoV, lily symptomless virus (LSV. Leaf samples were collected at lily-cultivation facilities located in the Kangwon province of Korea and used to evaluate the detection system. Simplex and multiplex RT-PCR were performed using virus-specific primers to detect single-or mixed viral infections in lily plants. Our results demonstrate the selective detection of 3 different viruses (CMV, LMoV and LSV by using specific primers as well as the potential of simultaneously detecting 2 or 3 different viruses in lily plants with mixed infections. Three sets of primers for each target virus, and one set of internal control primers were used to evaluate the detection system for efficiency, reliability, and reproducibility.

  13. A new multiple-stage electrocoagulation process on anaerobic digestion effluent to simultaneously reclaim water and clean up biogas.

    Science.gov (United States)

    Liu, Zhiguo; Stromberg, David; Liu, Xuming; Liao, Wei; Liu, Yan

    2015-03-21

    A new multiple-stage treatment process was developed via integrating electrocoagulation with biogas pumping to simultaneously reclaim anaerobic digestion effluent and clean up biogas. The 1st stage of electrocoagulation treatment under the preferred reaction condition led to removal efficiencies of 30%, 81%, 37% and >99.9% for total solids, chemical oxygen demand, total nitrogen and total phosphorus, respectively. Raw biogas was then used as a reactant and pumped into the effluent to simultaneously neutralize pH of the effluent and remove H2S in the biogas. The 2nd stage of electrocoagulation treatment on the neutralized effluent showed that under the selected reaction condition, additional 60% and 10% of turbidity and chemical oxygen demand were further removed. The study concluded a dual-purpose approach for the first time to synergistically combine biogas purification and water reclamation for anaerobic digestion system, which well addresses the downstream challenges of anaerobic digestion technology. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Simultaneous colour visualizations of multiple ALS point cloud attributes for land cover and vegetation analysis

    Science.gov (United States)

    Zlinszky, András; Schroiff, Anke; Otepka, Johannes; Mandlburger, Gottfried; Pfeifer, Norbert

    2014-05-01

    LIDAR point clouds hold valuable information for land cover and vegetation analysis, not only in the spatial distribution of the points but also in their various attributes. However, LIDAR point clouds are rarely used for visual interpretation, since for most users, the point cloud is difficult to interpret compared to passive optical imagery. Meanwhile, point cloud viewing software is available allowing interactive 3D interpretation, but typically only one attribute at a time. This results in a large number of points with the same colour, crowding the scene and often obscuring detail. We developed a scheme for mapping information from multiple LIDAR point attributes to the Red, Green, and Blue channels of a widely used LIDAR data format, which are otherwise mostly used to add information from imagery to create "photorealistic" point clouds. The possible combinations of parameters are therefore represented in a wide range of colours, but relative differences in individual parameter values of points can be well understood. The visualization was implemented in OPALS software, using a simple and robust batch script, and is viewer independent since the information is stored in the point cloud data file itself. In our case, the following colour channel assignment delivered best results: Echo amplitude in the Red, echo width in the Green and normalized height above a Digital Terrain Model in the Blue channel. With correct parameter scaling (but completely without point classification), points belonging to asphalt and bare soil are dark red, low grassland and crop vegetation are bright red to yellow, shrubs and low trees are green and high trees are blue. Depending on roof material and DTM quality, buildings are shown from red through purple to dark blue. Erroneously high or low points, or points with incorrect amplitude or echo width usually have colours contrasting from terrain or vegetation. This allows efficient visual interpretation of the point cloud in planar

  15. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    Directory of Open Access Journals (Sweden)

    Nick Baker

    2017-03-01

    Full Text Available In fast switching power semiconductors, the use of a fourth terminal to provide the reference potential for the gate signal—known as a kelvin-source terminal—is becoming common. The introduction of this terminal presents opportunities for condition monitoring systems. This article demonstrates how the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal-Oxide-Semiconductor-Field-Effect Transistors (MOSFETs, it is shown that there are opposing trends in the evolution of the on-state resistances of both the bond-wires and the MOSFET die. In summary, after 50,000 temperature cycles, the resistance of the bond-wires increased by up to 2 mΩ, while the on-state resistance of the MOSFET dies decreased by approximately 1 mΩ. The conventional failure precursor (monitoring a single forward voltage cannot distinguish between semiconductor die or bond-wire degradation. Therefore, the ability to monitor both these parameters due to the presence of an auxiliary-source terminal can provide more detailed information regarding the aging process of a device.

  16. A protocol for the refinement of NMR structures using simultaneously pseudocontact shift restraints from multiple lanthanide ions

    Energy Technology Data Exchange (ETDEWEB)

    Sala, Davide; Giachetti, Andrea; Luchinat, Claudio, E-mail: luchinat@cerm.unifi.it; Rosato, Antonio, E-mail: rosato@cerm.unifi.it [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2016-11-15

    The binding of paramagnetic metal ions to proteins produces a number of different effects on the NMR spectra of the system. In particular, when the magnetic susceptibility of the metal ion is anisotropic, pseudocontact shifts (PCSs) arise and can be easily measured. They constitute very useful restraints for the solution structure determination of metal-binding proteins. In this context, there has been great interest in the use of lanthanide(III) ions to induce PCSs in diamagnetic proteins, e.g. through the replacement native calcium(II) ions. By preparing multiple samples in each of which a different ion of the lanthanide series is introduced, it is possible to obtain multiple independent PCS datasets that can be used synergistically to generate protein structure ensembles (typically called bundles). For typical NMR-based determination of protein structure, it is necessary to perform an energetic refinement of such initial bundles to obtain final structures whose geometric quality is suitable for deposition in the PDB. This can be conveniently done by using restrained molecular dynamics simulations (rMD) in explicit solvent. However, there are no available protocols for rMD using multiple PCS datasets as part of the restraints. In this work, we extended the PCS module of the AMBER MD package to handle multiple datasets and tuned a previously developed protocol for NMR structure refinement to achieve consistent convergence with PCS restraints. Test calculations with real experimental data show that this new implementation delivers the expected improvement of protein geometry, resulting in final structures that are of suitable quality for deposition. Furthermore, we observe that also initial structures generated only with traditional restraints can be successfully refined using traditional and PCS restraints simultaneously.

  17. Simultaneous reconstruction of multiple depth images without off-focus points in integral imaging using a graphics processing unit.

    Science.gov (United States)

    Yi, Faliu; Lee, Jieun; Moon, Inkyu

    2014-05-01

    The reconstruction of multiple depth images with a ray back-propagation algorithm in three-dimensional (3D) computational integral imaging is computationally burdensome. Further, a reconstructed depth image consists of a focus and an off-focus area. Focus areas are 3D points on the surface of an object that are located at the reconstructed depth, while off-focus areas include 3D points in free-space that do not belong to any object surface in 3D space. Generally, without being removed, the presence of an off-focus area would adversely affect the high-level analysis of a 3D object, including its classification, recognition, and tracking. Here, we use a graphics processing unit (GPU) that supports parallel processing with multiple processors to simultaneously reconstruct multiple depth images using a lookup table containing the shifted values along the x and y directions for each elemental image in a given depth range. Moreover, each 3D point on a depth image can be measured by analyzing its statistical variance with its corresponding samples, which are captured by the two-dimensional (2D) elemental images. These statistical variances can be used to classify depth image pixels as either focus or off-focus points. At this stage, the measurement of focus and off-focus points in multiple depth images is also implemented in parallel on a GPU. Our proposed method is conducted based on the assumption that there is no occlusion of the 3D object during the capture stage of the integral imaging process. Experimental results have demonstrated that this method is capable of removing off-focus points in the reconstructed depth image. The results also showed that using a GPU to remove the off-focus points could greatly improve the overall computational speed compared with using a CPU.

  18. Monitoring urban greenness dynamics using multiple endmember spectral mixture analysis.

    Directory of Open Access Journals (Sweden)

    Muye Gan

    Full Text Available Urban greenness is increasingly recognized as an essential constituent of the urban environment and can provide a range of services and enhance residents' quality of life. Understanding the pattern of urban greenness and exploring its spatiotemporal dynamics would contribute valuable information for urban planning. In this paper, we investigated the pattern of urban greenness in Hangzhou, China, over the past two decades using time series Landsat-5 TM data obtained in 1990, 2002, and 2010. Multiple endmember spectral mixture analysis was used to derive vegetation cover fractions at the subpixel level. An RGB-vegetation fraction model, change intensity analysis and the concentric technique were integrated to reveal the detailed, spatial characteristics and the overall pattern of change in the vegetation cover fraction. Our results demonstrated the ability of multiple endmember spectral mixture analysis to accurately model the vegetation cover fraction in pixels despite the complex spectral confusion of different land cover types. The integration of multiple techniques revealed various changing patterns in urban greenness in this region. The overall vegetation cover has exhibited a drastic decrease over the past two decades, while no significant change occurred in the scenic spots that were studied. Meanwhile, a remarkable recovery of greenness was observed in the existing urban area. The increasing coverage of small green patches has played a vital role in the recovery of urban greenness. These changing patterns were more obvious during the period from 2002 to 2010 than from 1990 to 2002, and they revealed the combined effects of rapid urbanization and greening policies. This work demonstrates the usefulness of time series of vegetation cover fractions for conducting accurate and in-depth studies of the long-term trajectories of urban greenness to obtain meaningful information for sustainable urban development.

  19. Fining of Red Wine Monitored by Multiple Light Scattering.

    Science.gov (United States)

    Ferrentino, Giovanna; Ramezani, Mohsen; Morozova, Ksenia; Hafner, Daniela; Pedri, Ulrich; Pixner, Konrad; Scampicchio, Matteo

    2017-07-12

    This work describes a new approach based on multiple light scattering to study red wine clarification processes. The whole spectral signal (1933 backscattering points along the length of each sample vial) were fitted by a multivariate kinetic model that was built with a three-step mechanism, implying (1) adsorption of wine colloids to fining agents, (2) aggregation into larger particles, and (3) sedimentation. Each step is characterized by a reaction rate constant. According to the first reaction, the results showed that gelatin was the most efficient fining agent, concerning the main objective, which was the clarification of the wine, and consequently the increase in its limpidity. Such a trend was also discussed in relation to the results achieved by nephelometry, total phenols, ζ-potential, color, sensory, and electronic nose analyses. Also, higher concentrations of the fining agent (from 5 to 30 g/100 L) or higher temperatures (from 10 to 20 °C) sped up the process. Finally, the advantage of using the whole spectral signal vs classical univariate approaches was demonstrated by comparing the uncertainty associated with the rate constants of the proposed kinetic model. Overall, multiple light scattering technique showed a great potential for studying fining processes compared to classical univariate approaches.

  20. Simultaneous Structural Health Monitoring and Vibration Control of Adaptive Structures Using Smart Materials

    Directory of Open Access Journals (Sweden)

    Myung-Hyun Kim

    2002-01-01

    Full Text Available The integration of actuators and sensors using smart materials enabled various applications including health monitoring and structural vibration control. In this study, a robust control technique is designed and implemented in order to reduce vibration of an active structure. Special attention is given to eliminating the possibility of interaction between the health monitoring system and the control system. Exploiting the disturbance decoupling characteristic of the sliding mode observer, it is demonstrated that the proposed observer can eliminate the possible high frequency excitation from the health monitoring system. At the same time, a damage identification scheme, which tracks the changes of mechanical impedance due to the presence of damage, has been applied to assess the health condition of structures. The main objective of this paper is to examine the potential of combining the two emerging techniques together. Using the collocated piezoelectric sensors/actuators for vibration suppression as well as for health monitoring, this technique enabled to reduce the number of system components, while enhancing the performance of structures. As an initial study, both simulation and experimental investigations were performed for an active beam structure. The results show that this integrated technique can provide substantial vibration reductions, while detecting damage on the structure at the same time.

  1. Body fluid markers to monitor multiple sclerosis: The assays and the challenges

    NARCIS (Netherlands)

    Laman, J.D.; Thompson, E.J.; Kappos, L.

    1998-01-01

    The need for reliable markers of disease activity in multiple sclerosis (MS) to better guide basic research, diagnosis, treatment, and monitoring of therapy is well-recognized. A recent European Charcot Foundation Symposium (Body fluid markers for course and activity of disease in multiple sclerosis

  2. Extensive monitoring through multiple blood samples in professional soccer players

    DEFF Research Database (Denmark)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter

    2013-01-01

    of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. VO2max decreased towards the end of the season whereas no significant changes were observed in the IE2 test.The regular blood samples from elite soccer players reveal significant changes......ABSTRACT: The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players, and to analyze different blood parameters in relation to seasonal changes in training and match exposure.Blood samples were collected five times during a six...... months period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, players were tested for body composition, VO2max and physical performance by the Yo-Yo intermittent endurance sub-max test (IE2).Multiple variations in blood parameters occurred during...

  3. Intra-Day Simultaneous Optical Monitoring of S5 0716+714

    Directory of Open Access Journals (Sweden)

    Xiaoyuan Zhang

    2016-09-01

    Full Text Available We present the results of simultaneous optical multi-color observations of BL Lac object 0716+714 in November 2014 and February 2016. The intra-day variability (IDV varies from 0.04 to 0.3 mags. Both achromatic and bluer-when-brighter (BWB color behaviors were detected. A probable quasi-periodic oscillation overlapping on a significant flare was also observed. We used the interpolated cross-correlation function to calculate time lags between light curves in different bands. Variations in the B and R lagging behind that in the I band were found, which corresponds with anti-clockwise loops on the color-magnitude diagrams.

  4. Fast online simultaneous monitoring of PMD and chromatic dispersion with reduced polarization dependent gain

    Science.gov (United States)

    Ning, G.; Shum, P.; Aditya, S.; Gong, Yandong

    2006-09-01

    We use the expression relating the output state of polarization and PMD vector. Based on this expression we get the power fading including first-order PMD and chromatic dispersion, which is dependent on the angle of precession of output state of polarization around the PMD vector. From the expression for power fading, we get the average power penalty for chromatic dispersion and PMD. We propose a novel and fast PMD and chromatic dispersion monitoring technology. Measured results agree well with theoretical analysis.

  5. Nitrogen Cycle Evaluation (NiCE) Chip for the Simultaneous Analysis of Multiple N-Cycle Associated Genes.

    Science.gov (United States)

    Oshiki, Mamoru; Segawa, Takahiro; Ishii, Satoshi

    2018-02-02

    Various microorganisms play key roles in the Nitrogen (N) cycle. Quantitative PCR (qPCR) and PCR-amplicon sequencing of the N cycle functional genes allow us to analyze the abundance and diversity of microbes responsible in the N transforming reactions in various environmental samples. However, analysis of multiple target genes can be cumbersome and expensive. PCR-independent analysis, such as metagenomics and metatranscriptomics, is useful but expensive especially when we analyze multiple samples and try to detect N cycle functional genes present at relatively low abundance. Here, we present the application of microfluidic qPCR chip technology to simultaneously quantify and prepare amplicon sequence libraries for multiple N cycle functional genes as well as taxon-specific 16S rRNA gene markers for many samples. This approach, named as N cycle evaluation (NiCE) chip, was evaluated by using DNA from pure and artificially mixed bacterial cultures and by comparing the results with those obtained by conventional qPCR and amplicon sequencing methods. Quantitative results obtained by the NiCE chip were comparable to those obtained by conventional qPCR. In addition, the NiCE chip was successfully applied to examine abundance and diversity of N cycle functional genes in wastewater samples. Although non-specific amplification was detected on the NiCE chip, this could be overcome by optimizing the primer sequences in the future. As the NiCE chip can provide high-throughput format to quantify and prepare sequence libraries for multiple N cycle functional genes, this tool should advance our ability to explore N cycling in various samples. Importance. We report a novel approach, namely Nitrogen Cycle Evaluation (NiCE) chip by using microfluidic qPCR chip technology. By sequencing the amplicons recovered from the NiCE chip, we can assess diversities of the N cycle functional genes. The NiCE chip technology is applicable to analyze the temporal dynamics of the N cycle gene

  6. Extensive monitoring through multiple blood samples in professional soccer players.

    Science.gov (United States)

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L

    2013-05-01

    The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.

  7. An education management information system with simultaneous monitoring of stress stimulators for students Mental Health management.

    Science.gov (United States)

    Manimaran, S; Jayakumar, S; Lakshmi, K Bhagya

    2016-11-14

    Education Management Information System (EMIS) is a widely acceptable and developing technology within the Information Technology field. The advancement in technology in this century is being collaborated with scientific invention or explorer and information strengthening or development. This paper presents the results and experiences gained from applying students oriented EMIS for monitoring and managing mental health. The Mental Health of students depends on the acquiring adequate knowledge on basic concepts within a time period or academic schedule. It's obviously significance to evaluate and appraise the stress stimulators as a challenge or threat. The theoretical framework for the study was designed for analyzing the stress stimulators, academic performance and EMIS accessibility. The sample examined in this study was stratified random sample from 75 students specifically all engineering college in Dindigul District of Tamilnadu. The primary factor is the academic stress stimulators that form one module of EMIS for each of the key variable such as curriculum & instruction related stressors, placement related, teamwork related and assessment related. The Mental Health related stress stimulators namely curriculum & syllabus, placement related, assessment related and team work related have a significant influence on academic performance by students in various institution. The important factor leading to the EMIS application in monitoring stress stimulators is curriculum & syllabus related and assessment related.

  8. Simultaneous 3D localization of multiple MR-visible markers in fully reconstructed MR images: proof-of-concept for subsecond position tracking.

    Science.gov (United States)

    Thörmer, Gregor; Garnov, Nikita; Moche, Michael; Haase, Jürgen; Kahn, Thomas; Busse, Harald

    2012-04-01

    To determine whether a greatly reduced spatial resolution of fully reconstructed projection MR images can be used for the simultaneous 3D localization of multiple MR-visible markers and to assess the feasibility of a subsecond position tracking for clinical purposes. Miniature, inductively coupled RF coils were imaged in three orthogonal planes with a balanced steady-state free precession (SSFP) sequence and automatically localized using a two-dimensional template fitting and a subsequent three-dimensional (3D) matching of the coordinates. Precision, accuracy, speed and robustness of 3D localization were assessed for decreasing in-plane resolutions (0.6-4.7 mm). The feasibility of marker tracking was evaluated at the lowest resolution by following a robotically driven needle on a complex 3D trajectory. Average 3D precision and accuracy, sensitivity and specificity of localization ranged between 0.1 and 0.4 mm, 0.5 and 1.0 mm, 100% and 95%, and 100% and 96%, respectively. At the lowest resolution, imaging and localization took ≈350 ms and provided an accuracy of ≈1.0 mm. In the tracking experiment, the needle was clearly depicted on the oblique scan planes defined by the markers. Image-based marker localization at a greatly reduced spatial resolution is considered a feasible approach to monitor reference points or rigid instruments at subsecond update rates. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Acid Gastroesophageal Reflux Disease and Apparent Life-Threatening Events: Simultaneous pH-metry and Cardiorespiratory Monitoring.

    Science.gov (United States)

    Macchini, Francesco; Morandi, Anna; Cognizzoli, Paola; Farris, Giorgio; Gentilino, Valerio; Zanini, Andrea; Leva, Ernesto

    2017-02-01

    To investigate the prevalence and the characteristics of gastroesophageal reflux disease (GERD) in infants with apparent life threatening events (ALTE). Infants with at least one episode of ALTE in absence of predisposing factors were included. All infants underwent a cardiorespiratory recording with simultaneous 24-hour pH-monitoring. Patients were divided into 3 groups according to the severity of GERD: A. Reflux Index (RI) 7%. Monthly evaluations were performed and the anti-reflux therapy was maintained till normalization of monitoring and clinic. 41 infants were enrolled. GERD was found in 80% of patients (moderate in 54%, severe in 27%). A normalization of the cardiorespiratory tracks was recorded on average after 1 month for group A, 7 months for the group B and 9.5 months for group C. A significant difference was registered between group A and both group B and C (P < 0.0001), as well as between the group B and C (P < 0.05). GERD influences significantly the time of normalization of the cardiorespiratory monitoring in infants with ALTE. GERD diagnosis and treatment are mandatory in these patients. Copyright © 2016. Published by Elsevier B.V.

  10. First Simulations of Designing Stratospheric Sulfate Aerosol Geoengineering to Meet Multiple Simultaneous Climate Objectives: DESIGNING STRATOSPHERIC GEOENGINEERING

    Energy Technology Data Exchange (ETDEWEB)

    Kravitz, Ben [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; MacMartin, Douglas G. [Mechanical and Aerospace Engineering, Cornell University, Ithaca NY USA; Department of Computing and Mathematical Sciences, California Institute of Technology, Pasadena CA USA; Mills, Michael J. [Atmospheric Chemistry, Observations, and Modeling Laboratory, National Center for Atmospheric Research, Boulder CO USA; Richter, Jadwiga H. [Climate and Global Dynamics Laboratory, National Center for Atmospheric Research, Boulder CO USA; Tilmes, Simone [Atmospheric Chemistry, Observations, and Modeling Laboratory, National Center for Atmospheric Research, Boulder CO USA; Climate and Global Dynamics Laboratory, National Center for Atmospheric Research, Boulder CO USA; Lamarque, Jean-Francois [Atmospheric Chemistry, Observations, and Modeling Laboratory, National Center for Atmospheric Research, Boulder CO USA; Tribbia, Joseph J. [Climate and Global Dynamics Laboratory, National Center for Atmospheric Research, Boulder CO USA; Vitt, Francis [Atmospheric Chemistry, Observations, and Modeling Laboratory, National Center for Atmospheric Research, Boulder CO USA

    2017-12-07

    We describe the first simulations of stratospheric sulfate aerosol geoengineering using multiple injection locations to meet multiple simultaneous surface temperature objectives. Simulations were performed using CESM1(WACCM), a coupled atmosphere-ocean general circulation model with fully interactive stratospheric chemistry, dynamics (including an internally generated quasi-biennial oscillation), and a sophisticated treatment of sulfate aerosol formation, microphysical growth, and deposition. The objectives are defined as maintaining three temperature features at their 2020 levels against a background of the RCP8.5 scenario over the period 2020-2099. These objectives are met using a feedback mechanism in which the rate of sulfur dioxide injection at each of the four locations is adjusted independently every year of simulation. Even in the presence of uncertainties, nonlinearities, and variability, the objectives are met, predominantly by SO2 injection at 30°N and 30°S. By the last year of simulation, the feedback algorithm calls for a total injection rate of 51 Tg SO2 per year. The injections are not in the tropics, which results in a greater degree of linearity of the surface climate response with injection amount than has been found in many previous studies using injection at the equator. Because the objectives are defined in terms of annual mean temperature, the required geeongineering results in "overcooling" during summer and "undercooling" during winter. The hydrological cycle is also suppressed as compared to the reference values corresponding to the year 2020. The demonstration we describe in this study is an important step toward understanding what geoengineering can do and what it cannot do.

  11. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.

    Science.gov (United States)

    Jenkinson, Carl; Taylor, Angela E; Hassan-Smith, Zaki K; Adams, John S; Stewart, Paul M; Hewison, Martin; Keevil, Brian G

    2016-03-01

    Recent studies suggest that vitamin D-deficiency is linked to increased risk of common human health problems. To define vitamin D 'status' most routine analytical methods quantify one particular vitamin D metabolite, 25-hydroxyvitamin D3 (25OHD3). However, vitamin D is characterized by complex metabolic pathways, and simultaneous measurement of multiple vitamin D metabolites may provide a more accurate interpretation of vitamin D status. To address this we developed a high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyse multiple vitamin D analytes, with particular emphasis on the separation of epimer metabolites. A supportive liquid-liquid extraction (SLE) and LC-MS/MS method was developed to quantify 10 vitamin D metabolites as well as separation of an interfering 7α-hydroxy-4-cholesten-3-one (7αC4) isobar (precursor of bile acid), and validated by analysis of human serum samples. In a cohort of 116 healthy subjects, circulating concentrations of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (3-epi-25OHD3), 24,25-dihydroxyvitamin D3 (24R,25(OH)2D3), 1,25-dihydroxyvitamin D3 (1α,25(OH)2D3), and 25-hydroxyvitamin D2 (25OHD2) were quantifiable using 220μL of serum, with 25OHD3 and 24R,25(OH)2D3 showing significant seasonal variations. This high-throughput LC-MS/MS method provides a novel strategy for assessing the impact of vitamin D on human health and disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    Science.gov (United States)

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM

  13. Long open-path instrument for simultaneously monitoring of methane, CO2 and water vapor

    Science.gov (United States)

    Simeonov, Valentin; Parlange, Marc

    2013-04-01

    A new, long open-path instrument for monitoring of path-averaged methane, CO2 and water vapor concentrations will be presented. The instrument is built on the monostatic scheme (transceiver -distant retroreflector). A VCSEL with a central wavelength of 1654 nm is used as a light source. The receiver is built around a 20 cm Newtonian telescope. The design optical path length is 2000 m but can be further extended. To avoid distortions in the shape of the spectral lines caused by atmospheric turbulences they are scanned within 1 µs. The expected concentration resolution for the above mentioned path length is of the order of 2 ppb for methane, 100 ppb for CO2 and 100 ppm for water vapor. The instrument is developed at the Swiss Federal Institute of Technology - Lausanne (EPFL) Switzerland and will be used within the GAW+ CH program for long-term monitoring of background methane and CO2 concentrations in the Swiss Alps. The initial calibration validation tests at EPFL were completed in December 2012 and the instrument will be installed at the beginning of 2013 at the High Altitude Research Station Jungfraujoch (HARSJ). The HARSJ is located at 3580 m ASL and is one of the 24 global GAW stations. One of the goals of the project is to compare path-averaged to the ongoing point measurements of methane in order to identify possible influence of the station. Future deployments of a copy of the instrument include the Canadian arctic and Siberian wetlands. The instrument can be used for ground truthing of satellite observation as well.

  14. Monitoring multiple species: Estimating state variables and exploring the efficacy of a monitoring program

    Science.gov (United States)

    Mattfeldt, S.D.; Bailey, L.L.; Grant, E.H.C.

    2009-01-01

    Monitoring programs have the potential to identify population declines and differentiate among the possible cause(s) of these declines. Recent criticisms regarding the design of monitoring programs have highlighted a failure to clearly state objectives and to address detectability and spatial sampling issues. Here, we incorporate these criticisms to design an efficient monitoring program whose goals are to determine environmental factors which influence the current distribution and measure change in distributions over time for a suite of amphibians. In designing the study we (1) specified a priori factors that may relate to occupancy, extinction, and colonization probabilities and (2) used the data collected (incorporating detectability) to address our scientific questions and adjust our sampling protocols. Our results highlight the role of wetland hydroperiod and other local covariates in the probability of amphibian occupancy. There was a change in overall occupancy probabilities for most species over the first three years of monitoring. Most colonization and extinction estimates were constant over time (years) and space (among wetlands), with one notable exception: local extinction probabilities for Rana clamitans were lower for wetlands with longer hydroperiods. We used information from the target system to generate scenarios of population change and gauge the ability of the current sampling to meet monitoring goals. Our results highlight the limitations of the current sampling design, emphasizing the need for long-term efforts, with periodic re-evaluation of the program in a framework that can inform management decisions.

  15. Simultaneous dual-functioning InGaN/GaN multiple-quantum-well diode for transferrable optoelectronics

    Science.gov (United States)

    Shi, Zheng; Yuan, Jialei; Zhang, Shuai; Liu, Yuhuai; Wang, Yongjin

    2017-10-01

    We propose a wafer-level procedure for the fabrication of 1.5-mm-diameter dual functioning InGaN/GaN multiple-quantum-well (MQW) diodes on a GaN-on-silicon platform for transferrable optoelectronics. Nitride semiconductor materials are grown on (111) silicon substrates with intermediate Al-composition step-graded buffer layers, and membrane-type MQW-diode architectures are obtained by a combination of silicon removal and III-nitride film backside thinning. Suspended MQW-diodes are directly transferred from silicon to foreign substrates such as metal, glass and polyethylene terephthalate by mechanically breaking the support beams. The transferred MQW-diodes display strong electroluminescence under current injection and photodetection under light irradiation. Interestingly, they demonstrate a simultaneous light-emitting light-detecting function, endowing the 1.5-mm-diameter MQW-diode with the capability of producing transferrable optoelectronics for adjustable displays, wearable optical sensors, multifunctional energy harvesting, flexible light communication and monolithic photonic circuit.

  16. Optimization and modeling of spot welding parameters with simultaneous multiple response consideration using multi objective Taguchi method and RSM

    Energy Technology Data Exchange (ETDEWEB)

    Muhammad, Nora Siah; Manurung Yupiter HP; Hafidzi, Moham Mad; Abas, Sun Haji Kiyai; Tham, Ghalib; Haru Man, Esa [Universiti Teknologi MARA (UiTM), Selangor (Malaysia)

    2012-08-15

    This paper presents an alternative method to optimize process parameters of resistance spot welding (RSW) towards weld zone development. The optimization approach attempts to consider simultaneously the multiple quality characteristics, namely weld nugget and heat affected zone (HAZ), using multi objective Taguchi method (MTM). The experimental study was conducted for plate thickness of 1.5mm under different welding current, weld time and hold time. The optimum welding parameters were investigated using the Taguchi method with L9 orthogonal array. The optimum value was analyzed by means of MTM, which involved the calculation of total normalized quality loss (TNQL) and multi signal to noise ratio (MSNR). A significant level of the welding parameters was further obtained by using analysis of variance (ANOVA). Furthermore, the first order model for predicting the weld zone development is derived by using response surface methodology (RSM). Based on the experimental confirmation test, the proposed method can be effectively applied to estimate the size of weld zone, which can be used to enhance and optimized the welding performance in RSW or other application.

  17. Evaluation of simultaneous binding of Chromomycin A3 to the multiple sites of DNA by the new restriction enzyme assay.

    Science.gov (United States)

    Murase, Hirotaka; Noguchi, Tomoharu; Sasaki, Shigeki

    2018-06-01

    Chromomycin A3 (CMA3) is an aureolic acid-type antitumor antibiotic. CMA3 forms dimeric complexes with divalent cations, such as Mg 2+ , which strongly binds to the GC rich sequence of DNA to inhibit DNA replication and transcription. In this study, the binding property of CMA3 to the DNA sequence containing multiple GC-rich binding sites was investigated by measuring the protection from hydrolysis by the restriction enzymes, AccII and Fnu4HI, for the center of the CGCG site and the 5'-GC↓GGC site, respectively. In contrast to the standard DNase I footprinting method, the DNA substrates are fully hydrolyzed by the restriction enzymes, therefore, the full protection of DNA at all the cleavable sites indicates that CMA3 simultaneously binds to all the binding sites. The restriction enzyme assay has suggested that CMA3 has a high tendency to bind the successive CGCG sites and the CGG repeat. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Comparative performance evaluation of multi-metal resistant fungal strains for simultaneous removal of multiple hazardous metals.

    Science.gov (United States)

    Dey, Priyadarshini; Gola, Deepak; Mishra, Abhishek; Malik, Anushree; Kumar, Peeyush; Singh, Dileep Kumar; Patel, Neelam; von Bergen, Martin; Jehmlich, Nico

    2016-11-15

    In the present study, five fungal strains viz., Aspergillus terreus AML02, Paecilomyces fumosoroseus 4099, Beauveria bassiana 4580, Aspergillus terreus PD-17, Aspergillus fumigatus PD-18, were screened for simultaneous multimetal removal. Highest metal tolerance index for each individual metal viz., Cd, Cr, Cu, Ni, Pb and Zn (500mg/L) was recorded for A. fumigatus for the metals (Cd, 0.72; Cu, 0.72; Pb, 1.02; Zn, 0.94) followed by B. bassiana for the metals (Cd, 0.56; Cu, 0.14; Ni, 0.29; Zn, 0.85). Next, the strains were exposed to multiple metal mixture (Cd, Cr, Cu, Ni, Pb and Zn) of various concentrations (6, 12, 18, 30mg/L). Compared to other strains, B. bassiana and A. fumigatus had higher cube root growth (k) constants indicating their better adaptability to multi metal stress. After 72h, multimetal accumulation potential of B. bassiana (26.94±0.07mg/L) and A. fumigatus (27.59±0.09mg/L) were higher than the other strains at initial multimetal concentration of 30mg/L. However, considering the post treatment concentrations of individual metals in multimetal mixture (at all the tested concentrations), A. fumigatus demonstrated exceptional performance and could bring down the concentrations of Cd, Cu, Ni, Pb and Zn below the threshold level for irrigation prescribed by Food and Agriculture Organization (FAO). Copyright © 2016 Elsevier B.V. All rights reserved.

  19. An efficient method to transcription factor binding sites imputation via simultaneous completion of multiple matrices with positional consistency.

    Science.gov (United States)

    Guo, Wei-Li; Huang, De-Shuang

    2017-08-22

    Transcription factors (TFs) are DNA-binding proteins that have a central role in regulating gene expression. Identification of DNA-binding sites of TFs is a key task in understanding transcriptional regulation, cellular processes and disease. Chromatin immunoprecipitation followed by high-throughput sequencing (ChIP-seq) enables genome-wide identification of in vivo TF binding sites. However, it is still difficult to map every TF in every cell line owing to cost and biological material availability, which poses an enormous obstacle for integrated analysis of gene regulation. To address this problem, we propose a novel computational approach, TFBSImpute, for predicting additional TF binding profiles by leveraging information from available ChIP-seq TF binding data. TFBSImpute fuses the dataset to a 3-mode tensor and imputes missing TF binding signals via simultaneous completion of multiple TF binding matrices with positional consistency. We show that signals predicted by our method achieve overall similarity with experimental data and that TFBSImpute significantly outperforms baseline approaches, by assessing the performance of imputation methods against observed ChIP-seq TF binding profiles. Besides, motif analysis shows that TFBSImpute preforms better in capturing binding motifs enriched in observed data compared with baselines, indicating that the higher performance of TFBSImpute is not simply due to averaging related samples. We anticipate that our approach will constitute a useful complement to experimental mapping of TF binding, which is beneficial for further study of regulation mechanisms and disease.

  20. Optimization and modeling of spot welding parameters with simultaneous multiple response consideration using multi objective Taguchi method and RSM

    International Nuclear Information System (INIS)

    Muhammad, Nora Siah; Manurung Yupiter HP; Hafidzi, Moham Mad; Abas, Sun Haji Kiyai; Tham, Ghalib; Haru Man, Esa

    2012-01-01

    This paper presents an alternative method to optimize process parameters of resistance spot welding (RSW) towards weld zone development. The optimization approach attempts to consider simultaneously the multiple quality characteristics, namely weld nugget and heat affected zone (HAZ), using multi objective Taguchi method (MTM). The experimental study was conducted for plate thickness of 1.5mm under different welding current, weld time and hold time. The optimum welding parameters were investigated using the Taguchi method with L9 orthogonal array. The optimum value was analyzed by means of MTM, which involved the calculation of total normalized quality loss (TNQL) and multi signal to noise ratio (MSNR). A significant level of the welding parameters was further obtained by using analysis of variance (ANOVA). Furthermore, the first order model for predicting the weld zone development is derived by using response surface methodology (RSM). Based on the experimental confirmation test, the proposed method can be effectively applied to estimate the size of weld zone, which can be used to enhance and optimized the welding performance in RSW or other application

  1. Non-invasive imaging and monitoring of rodent retina using simultaneous dual-band optical coherence tomography

    Science.gov (United States)

    Cimalla, Peter; Burkhardt, Anke; Walther, Julia; Hoefer, Aline; Wittig, Dierk; Funk, Richard; Koch, Edmund

    2011-03-01

    Spectral domain dual-band optical coherence tomography for simultaneous imaging of rodent retina in the 0.8 μm and 1.3 μm wavelength region and non-invasive monitoring of the posterior eye microstructure in the field of retinal degeneration research is demonstrated. The system is illuminated by a supercontinuum laser source and allows three-dimensional imaging with high axial resolution better than 3.8 μm and 5.3 μm in tissue at 800 nm and 1250 nm, respectively, for precise retinal thickness measurements. A fan-shaped scanning pattern with the pivot point close to the eye's pupil and a contact lens are applied to obtain optical access to the eye's fundus. First in vivo experiments in a RCS (royal college of surgeons) rat model with gene-related degeneration of the photoreceptor cells show good visibility of the retinal microstructure with sufficient contrast for thickness measurement of individual retinal layers. An enhanced penetration depth at 1250 nm is clearly identifiable revealing sub-choroidal structures that are not visible at 800 nm. Furthermore, additional simultaneous imaging at 1250 nm improves image quality by frequency compounding speckle noise reduction. These results are encouraging for time course studies of the rodent retina concerning its development related to disease progression and treatment response.

  2. Quantitative Single-letter Sequencing: a method for simultaneously monitoring numerous known allelic variants in single DNA samples

    Directory of Open Access Journals (Sweden)

    Duborjal Hervé

    2008-02-01

    Full Text Available Abstract Background Pathogens such as fungi, bacteria and especially viruses, are highly variable even within an individual host, intensifying the difficulty of distinguishing and accurately quantifying numerous allelic variants co-existing in a single nucleic acid sample. The majority of currently available techniques are based on real-time PCR or primer extension and often require multiplexing adjustments that impose a practical limitation of the number of alleles that can be monitored simultaneously at a single locus. Results Here, we describe a novel method that allows the simultaneous quantification of numerous allelic variants in a single reaction tube and without multiplexing. Quantitative Single-letter Sequencing (QSS begins with a single PCR amplification step using a pair of primers flanking the polymorphic region of interest. Next, PCR products are submitted to single-letter sequencing with a fluorescently-labelled primer located upstream of the polymorphic region. The resulting monochromatic electropherogram shows numerous specific diagnostic peaks, attributable to specific variants, signifying their presence/absence in the DNA sample. Moreover, peak fluorescence can be quantified and used to estimate the frequency of the corresponding variant in the DNA population. Using engineered allelic markers in the genome of Cauliflower mosaic virus, we reliably monitored six different viral genotypes in DNA extracted from infected plants. Evaluation of the intrinsic variance of this method, as applied to both artificial plasmid DNA mixes and viral genome populations, demonstrates that QSS is a robust and reliable method of detection and quantification for variants with a relative frequency of between 0.05 and 1. Conclusion This simple method is easily transferable to many other biological systems and questions, including those involving high throughput analysis, and can be performed in any laboratory since it does not require specialized

  3. A data fusion approach for track monitoring from multiple in-service trains

    Science.gov (United States)

    Lederman, George; Chen, Siheng; Garrett, James H.; Kovačević, Jelena; Noh, Hae Young; Bielak, Jacobo

    2017-10-01

    We present a data fusion approach for enabling data-driven rail-infrastructure monitoring from multiple in-service trains. A number of researchers have proposed using vibration data collected from in-service trains as a low-cost method to monitor track geometry. The majority of this work has focused on developing novel features to extract information about the tracks from data produced by individual sensors on individual trains. We extend this work by presenting a technique to combine extracted features from multiple passes over the tracks from multiple sensors aboard multiple vehicles. There are a number of challenges in combining multiple data sources, like different relative position coordinates depending on the location of the sensor within the train. Furthermore, as the number of sensors increases, the likelihood that some will malfunction also increases. We use a two-step approach that first minimizes position offset errors through data alignment, then fuses the data with a novel adaptive Kalman filter that weights data according to its estimated reliability. We show the efficacy of this approach both through simulations and on a data-set collected from two instrumented trains operating over a one-year period. Combining data from numerous in-service trains allows for more continuous and more reliable data-driven monitoring than analyzing data from any one train alone; as the number of instrumented trains increases, the proposed fusion approach could facilitate track monitoring of entire rail-networks.

  4. Children’s comprehension monitoring of multiple situational dimensions of a narrative.

    NARCIS (Netherlands)

    Wassenburg, S.I.; Beker, K.; van den Broek, P.; van der Schoot, M.

    2015-01-01

    Narratives typically consist of information on multiple aspects of a situation. In order to successfully create a coherent representation of the described situation, readers are required to monitor all these situational dimensions during reading. However, little is known about whether these

  5. Assessment and monitoring of patients receiving chemotherapy for multiple myeloma: strategies to improve outcomes

    Directory of Open Access Journals (Sweden)

    Faiman B

    2016-05-01

    Full Text Available Beth Faiman, Jason Valent Department of Hematologic Oncology and Blood Disorders, Cleveland Clinic Taussig Cancer Institute, Cleveland, OH, USA Abstract: Improved understanding as to the biology of multiple myeloma (MM and the bone marrow microenvironment has led to the development of new drugs to treat MM. This explosion of new and highly effective drugs has led to dramatic advances in the management of MM and underscores the need for supportive care. Impressive and deep response rates to chemotherapy, monoclonal antibodies, and small molecule drugs provide hope of a cure or prolonged remission for the majority of individuals. For most patients, long-term, continuous therapy is often required to suppress the malignant plasma cell clone, thus requiring clinicians to become more astute in assessment, monitoring, and intervention of side effects as well as monitoring response to therapy. Appropriate diagnosis and monitoring strategies are essential to ensure that patients receive the appropriate chemotherapy and supportive therapy at relapse, and that side effects are appropriately managed to allow for continued therapy and adherence to the regimen. Multiple drugs with complex regimens are currently available with varying side effect profiles. Knowledge of the drugs used to treat MM and the common adverse events will allow for preventative strategies to mitigate adverse events and prompt intervention. The purpose of this paper is to review updates in the diagnosis and management of MM, and to provide strategies for assessment and monitoring of patients receiving chemotherapy for MM. Keywords: multiple myeloma, treatment, symptoms, assessment, monitoring, symptom management, targeted therapies

  6. Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

    Science.gov (United States)

    Wan, Hao; Yin, Heyu; Lin, Lu; Zeng, Xiangqun; Mason, Andrew J

    2018-02-01

    The growing impact of airborne pollutants and explosive gases on human health and occupational safety has escalated the demand of sensors to monitor hazardous gases. This paper presents a new miniaturized planar electrochemical gas sensor for rapid measurement of multiple gaseous hazards. The gas sensor features a porous polytetrafluoroethylene substrate that enables fast gas diffusion and room temperature ionic liquid as the electrolyte. Metal sputtering was utilized for platinum electrodes fabrication to enhance adhesion between the electrodes and the substrate. Together with carefully selected electrochemical methods, the miniaturized gas sensor is capable of measuring multiple gases including oxygen, methane, ozone and sulfur dioxide that are important to human health and safety. Compared to its manually-assembled Clark-cell predecessor, this sensor provides better sensitivity, linearity and repeatability, as validated for oxygen monitoring. With solid performance, fast response and miniaturized size, this sensor is promising for deployment in wearable devices for real-time point-of-exposure gas pollutant monitoring.

  7. A temporal study on #betta#2-microglobulin as marker for diagnosis and monitoring of multiple myeloma

    International Nuclear Information System (INIS)

    Neri, B.

    1982-01-01

    The most important objective carried on, in the field of oncology has been the finding of new means to improve diagnosis and monitoring of neoplastic diseases. So we have chronobiologically studied the behaviour of #betta# 2 -microglobulin, in three groups of patients: Group A: 11 healthy subjects; Group B: 11 untreated patients with multiple myeloma and Group C: 11 multiple myeloma patients, after treatment with polychemoterapy. #betta# 2 -microglobulin, was assayed in serum obtained at six consecutive 4-hourly intervals, by radioimmunoassay, the levels and the various rhythm parameters were analyzed by ''Group mean cosinor'' test. The data suggest, that a circadian rhythm for #betta# 2 -microglobulin in the three groups is not detectable; but ''mesor test'' establishes significant differences (p 2 -microglobulin, in diagnosis and monitoring of multiple myeloma, is suggested

  8. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    International Nuclear Information System (INIS)

    Bin Abas, Faizulsalihin; Takayama, Shigeru

    2015-01-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and ''Cloud'' System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster

  9. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    Science.gov (United States)

    Abas, Faizulsalihin bin; Takayama, Shigeru

    2015-02-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and "Cloud" System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster.

  10. Simultaneous Determination of Multiple Components in Guanjiekang in Rat Plasma via the UPLC–MS/MS Method and Its Application in Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Jian Wu

    2016-12-01

    Full Text Available Guanjiekang (GJK that is formed by five medicinal herbs including Astragali Radix, Aconiti Lateralis Radix Praeparaia, Glycyrrhizae Radix et Rhizoma, Corydalis Rhizoma and Paeoniae Radix Alba was used for the treatment of rheumatoid arthritis (RA. However, the pharmacokinetic (PK profile of active components in GJK remains unclear. This study aims to evaluate the pharmacokinetic behavior of seven representative active constituents in GJK (i.e., benzoylhypaconine, benzoylmesaconine, paeoniflorin, tetrahydropalmatine, calycosin-7-glucoside, formononetin and isoliquiritigenin after oral administration of GJK in rats. A rapid, sensitive and reliable ultra-performance liquid chromatography-tandem mass spectrometer (UPLC–MS/MS method has been successfully developed for the simultaneous determination of these seven constituents in rat plasma. Chromatographic separation was achieved on a C18 column with a gradient elution program that consists of acetonitrile and water (containing 0.1% formic acid at a flow rate of 0.35 mL/min. Detection was performed under the multiple reaction monitoring (MRM in the positive electrospray ionization (ESI mode. The calibration curves exhibited good linearity (R2 > 0.99 over a wide concentration range for all constituents. The accuracies ranged from 92.9% to 107.8%, and the intra-day and inter-day precisions at three different levels were below 15%. Our PK results showed that these seven compounds were quickly absorbed after the administration of the GJK product, and Tmax ranged from 30 min to 189 min. The in vivo concentrations of paeoniflorin and isoliquiritigenin were significantly higher than the reported in vitro effective doses, indicating that they could partly contribute to the therapeutic effect of GJK. Therefore, we conclude that pharmacokinetic studies of representative bioactive chemicals after administration of complex herbal products are not only necessary but also feasible. Moreover, these seven

  11. Monitoring volcanic ash cloud top height through simultaneous retrieval of optical data from polar orbiting and geostationary satellites

    Directory of Open Access Journals (Sweden)

    K. Zakšek

    2013-03-01

    Full Text Available Volcanic ash cloud-top height (ACTH can be monitored on the global level using satellite remote sensing. Here we propose a photogrammetric method based on the parallax between data retrieved from geostationary and polar orbiting satellites to overcome some limitations of the existing methods of ACTH retrieval. SEVIRI HRV band and MODIS band 1 are a good choice because of their high resolution. The procedure works well if the data from both satellites are retrieved nearly simultaneously. MODIS does not retrieve the data at exactly the same time as SEVIRI. To compensate for advection we use two sequential SEVIRI images (one before and one after the MODIS retrieval and interpolate the cloud position from SEVIRI data to the time of MODIS retrieval. The proposed method was tested for the case of the Eyjafjallajökull eruption in April 2010. The parallax between MODIS and SEVIRI data can reach 30 km, which implies an ACTH of approximately 12 km at the beginning of the eruption. At the end of April eruption an ACTH of 3–4 km is observed. The accuracy of ACTH was estimated to be 0.6 km.

  12. Simultaneous measurement of free-living energy expenditure by the doubly labeled water method and heart-rate monitoring

    International Nuclear Information System (INIS)

    Livingstone, M.B.; Prentice, A.M.; Coward, W.A.; Ceesay, S.M.; Strain, J.J.; McKenna, P.G.; Nevin, G.B.; Barker, M.E.; Hickey, R.J.

    1990-01-01

    Total energy expenditure (TEE) was measured simultaneously in 14 free-living adults over 15 d by the doubly labeled water (DLW) method and for 2-4 separate days by heart-rate (HR) monitoring. Individual curves for HR vs oxygen consumption (VO2) were obtained and an HR (FLEX HR: 97 +/- 8 beats/min, range 84-113 beats/min) that discriminated between rest and activity was identified. Calibration curves were used to assign an energy value to daytime HR above FLEX HR. Below FLEX HR energy expenditure was taken as resting metabolism. Sleeping energy expenditure was assumed to be equal to basal metabolic rate. Average HR TEE (12.99 +/- 3.83 MJ/d) and average DLW TEE (12.89 +/- 3.80 MJ/d) were similar. HR TEE discrepancies ranged from -22.2% to +52.1%, with nine values lying within +/- 10% of DLW TEE estimates. The FLEX HR method provides a close estimation of the TEE of population groups. However, an increased number of sampling days may improve the precision of individual estimates of TEE

  13. Primary Multiple Simultaneous Intracerebral Hemorrhages between 1950 and 2013: Analysis of Data on Age, Sex and Outcome

    Directory of Open Access Journals (Sweden)

    Denchai Laiwattana

    2014-05-01

    Full Text Available Background: Primary multiple simultaneous intracerebral hemorrhages (MSICHs are quite rare. Although occasional reports have been found, there have been no systematic reviews. The published case reports and case series contain overlapping data, leading to erroneous information about MSICHs. This is the first extensive review of accessible studies published in English on MSICHs. Our primary objective was to analyze the demographic data on age, sex, outcome and prognosis with regard to primary MSICHs. Summary: A PubMed search without language restriction for articles with results from human studies and registered between January 1950 and September 2013 yielded 677 articles. The following inclusion criteria were applied: (1 reported case(s or case series on primary MSICHs; (2 text partly or fully in English, and (3 text contains identifiable data on age, sex and outcome of patients. A total of 24 articles met all the inclusion criteria. The reference lists of these 24 articles were inspected for additional relevant articles, which yielded another 20 articles. In all, 248 cases were identified; 143 cases were excluded for various reasons: 52 duplicate cases, 18 cases of multiple nonsimultaneous intracerebral hemorrhages, 25 cases of secondary MSICHs, and 48 cases with incomplete data on age, sex and outcome. The remaining 105 cases were analyzed. MSICHs were found to be more common in bilateral cases (53.33%: there were bilateral basal ganglia hemorrhages (33.33%, bilateral thalamic hemorrhages (18.10%, bilateral lobar hemorrhages (0.95% and bilateral cerebellar hemorrhages (0.95%. Nonbilateral MSICHs were found in 46.67% of the cases. The hematomas were commonly distributed in the basal ganglia (45.83%, thalamus (30.56% and cerebellum (10.19%. MSICHs were more frequently encountered in males (60.95%; average age: 59.13 ± 12.49 years. The average age of the female patients was higher (63.89 ± 13.11 years. Patients with primary MSICHs had a

  14. Primary Multiple Simultaneous Intracerebral Hemorrhages between 1950 and 2013: Analysis of Data on Age, Sex and Outcome.

    Science.gov (United States)

    Laiwattana, Denchai; Sangsawang, Bussara; Sangsawang, Nucharee

    2014-01-01

    Primary multiple simultaneous intracerebral hemorrhages (MSICHs) are quite rare. Although occasional reports have been found, there have been no systematic reviews. The published case reports and case series contain overlapping data, leading to erroneous information about MSICHs. This is the first extensive review of accessible studies published in English on MSICHs. Our primary objective was to analyze the demographic data on age, sex, outcome and prognosis with regard to primary MSICHs. A PubMed search without language restriction for articles with results from human studies and registered between January 1950 and September 2013 yielded 677 articles. The following inclusion criteria were applied: (1) reported case(s) or case series on primary MSICHs; (2) text partly or fully in English, and (3) text contains identifiable data on age, sex and outcome of patients. A total of 24 articles met all the inclusion criteria. The reference lists of these 24 articles were inspected for additional relevant articles, which yielded another 20 articles. In all, 248 cases were identified; 143 cases were excluded for various reasons: 52 duplicate cases, 18 cases of multiple nonsimultaneous intracerebral hemorrhages, 25 cases of secondary MSICHs, and 48 cases with incomplete data on age, sex and outcome. The remaining 105 cases were analyzed. MSICHs were found to be more common in bilateral cases (53.33%): there were bilateral basal ganglia hemorrhages (33.33%), bilateral thalamic hemorrhages (18.10%), bilateral lobar hemorrhages (0.95%) and bilateral cerebellar hemorrhages (0.95%). Nonbilateral MSICHs were found in 46.67% of the cases. The hematomas were commonly distributed in the basal ganglia (45.83%), thalamus (30.56%) and cerebellum (10.19%). MSICHs were more frequently encountered in males (60.95%; average age: 59.13 ± 12.49 years). The average age of the female patients was higher (63.89 ± 13.11 years). Patients with primary MSICHs had a survival rate of 56.20%. There

  15. Multiple bio-monitoring system using visible light for electromagnetic-wave free indoor healthcare

    Science.gov (United States)

    An, Jinyoung; Pham, Ngoc Quan; Chung, Wan-Young

    2017-12-01

    In this paper, a multiple biomedical data transmission system with visible light communication (VLC) is proposed for an electromagnetic-wave-free indoor healthcare. VLC technology has emerged as an alternative solution to radio-frequency (RF) wireless systems, due to its various merits, e.g., ubiquity, power efficiency, no RF radiation, and security. With VLC, critical bio-medical signals, including electrocardiography (ECG), can be transmitted in places where RF radiation is restricted. This potential advantage of VLC could save more lives in emergency situations. A time hopping (TH) scheme is employed to transfer multiple medical-data streams in real time with a simple system design. Multiple data streams are transmitted using identical color LEDs and go into an optical detector. The received multiple data streams are demodulated and rearranged using a TH-based demodulator. The medical data is then monitored and managed to provide the necessary medical care for each patient.

  16. Incidence of multiple sclerosis among European Economic Area populations, 1985-2009: the framework for monitoring

    Science.gov (United States)

    2013-01-01

    Background A debate surrounding multiple sclerosis epidemiology has centred on time-related incidence increases and the need of monitoring. The purpose of this study is to reassess multiple sclerosis incidence in the European Economic Area. Methods We conducted a systematic review of literature from 1965 onwards and integrated elements of original research, including requested or completed data by surveys authors and specific analyses. Results The review of 5323 documents yielded ten studies for age- and sex-specific analyses, and 21 studies for time-trend analysis of single data sets. After 1985, the incidence of multiple sclerosis ranged from 1.12 to 6.96 per 100,000 population, was higher in females, tripled with latitude, and doubled with study midpoint year. The north registered increasing trends from the 1960s and 1970s, with a historic drop in the Faroe Islands, and fairly stable data in the period 1980-2000; incidence rose in Italian and French populations in the period 1970-2000, in Evros (Greece) in the 1980s, and in the French West Indies in around 2000. Conclusions We conclude that the increase in multiple sclerosis incidence is only apparent, and that it is not specific to women. Monitoring of multiple sclerosis incidence might be appropriate for the European Economic Area. PMID:23758972

  17. Finding Multiple Peaks Signal in Fast Beam Conditions Monitor (BCM1F)

    CERN Document Server

    Bin Ab Maalek, Abu Ubaidah Amir; CERN. Geneva. EP Department

    2017-01-01

    Fast Beam Conditions Monitor (BCM1F) is diamond and silicon sensors based luminometer of CMS detector. The methods of finding multiple peaks signal in BCM1F is shown. Multiple peaks signal found at signal with width between 60 ns - 300 ns. Double peaks are counted as single hit in the constant threshold analysis and leads to underestimation in the luminosity. Therefore it should be estimated for different filling schemes and sensor types. The percentage of long width pulse in different sensor for different fill are calculated. About 30 \\% long width pulse found in sCVD sensor, 12 \\% in pCVD and no more than 1 \\% for silicon sensor.

  18. 40 CFR 75.16 - Special provisions for monitoring emissions from common, bypass, and multiple stacks for SO2...

    Science.gov (United States)

    2010-07-01

    ... emissions from common, bypass, and multiple stacks for SO2 emissions and heat input determinations. 75.16... emissions from common, bypass, and multiple stacks for SO2 emissions and heat input determinations. (a... maintain an SO2 continuous emission monitoring system and flow monitoring system in the duct to the common...

  19. A New Method for Simultaneous Measurement of the Integrated Reflectivity of Crystals at Multiple Orders of Reflection and Comparison with New Theoretical Calculations

    International Nuclear Information System (INIS)

    Lee, S.G.; Bak, J.G.; Jung, Y.S.; Bitter, M.; Hill, K.W.; Hoelzer, G.; Wehrhan, O.; Foerster, E.

    2003-01-01

    This paper describes a new method for the simultaneous measurement of the integrated reflectivity of a crystal for multiple orders of reflection at a predefined Bragg angle. The technique is demonstrated with a mica crystal for Bragg angles of 43 o , 47 o , and 50 o . The measured integrated reflectivity for Bragg reflections up to the 24th order is compared with new theoretical predictions, which are also presented in this paper

  20. Retrospective Evaluation of Safety, Efficacy and Risk Factors for Pneumothorax in Simultaneous Localizations of Multiple Pulmonary Nodules Using Hook Wire System.

    Science.gov (United States)

    Zhong, Yan; Xu, Xiao-Quan; Pan, Xiang-Long; Zhang, Wei; Xu, Hai; Yuan, Mei; Kong, Ling-Yan; Pu, Xue-Hui; Chen, Liang; Yu, Tong-Fu

    2017-09-01

    To evaluate the safety and efficacy of the hook wire system in the simultaneous localizations for multiple pulmonary nodules (PNs) before video-assisted thoracoscopic surgery (VATS), and to clarify the risk factors for pneumothorax associated with the localization procedure. Between January 2010 and February 2016, 67 patients (147 nodules, Group A) underwent simultaneous localizations for multiple PNs using a hook wire system. The demographic, localization procedure-related information and the occurrence rate of pneumothorax were assessed and compared with a control group (349 patients, 349 nodules, Group B). Multivariate logistic regression analyses were used to determine the risk factors for pneumothorax during the localization procedure. All the 147 nodules were successfully localized. Four (2.7%) hook wires dislodged before VATS procedure, but all these four lesions were successfully resected according to the insertion route of hook wire. Pathological diagnoses were acquired for all 147 nodules. Compared with Group B, Group A demonstrated significantly longer procedure time (p pneumothorax (p = 0.019). Multivariate logistic regression analysis indicated that position change during localization procedure (OR 2.675, p = 0.021) and the nodules located in the ipsilateral lung (OR 9.404, p pneumothorax. Simultaneous localizations for multiple PNs using a hook wire system before VATS procedure were safe and effective. Compared with localization for single PN, simultaneous localizations for multiple PNs were prone to the occurrence of pneumothorax. Position change during localization procedure and the nodules located in the ipsilateral lung were independent risk factors for pneumothorax.

  1. MR in the diagnosis and monitoring of multiple sclerosis: An overview

    International Nuclear Information System (INIS)

    Rovira, Alex; Leon, Adelaida

    2008-01-01

    Multiple sclerosis is a chronic, persistent inflammatory-demyelinating disease of the central nervous system that typically presents as an acute clinically isolated syndrome attributable to a monofocal or multifocal demyelinating lesion, which usually affects the optic nerve, spinal cord, or brainstem and cerebellum. Although the diagnosis of multiple sclerosis is still based on clinical findings, magnetic resonance imaging is now integrated in the overall diagnostic scheme of the disease because of its unique sensitivity to demonstrate the spatial and temporal dissemination of demyelinating plaques in the brain and spinal cord. Conventional magnetic resonance imaging techniques, such as T2-weighted and gadolinium-enhanced T1-weighted sequences are highly sensitive in detecting multiple sclerosis plaques and provide a quantitative assessment of inflammatory activity and lesion load. However, there is a persisting mismatch between clinical and magnetic resonance imaging efficacy of approved treatments, which underlies the fact that this technique does not suffice to explain the entire spectrum of the disease process. In recent years, great effort has been dedicated to overcoming these limitations by using non-conventional magnetic resonance-derived metrics that can selectively measure the more destructive aspects of multiple sclerosis pathology and monitor the reparative mechanisms. These metrics, which include unenhanced T1-weighted imaging, measures of central nervous system atrophy, magnetization transfer imaging, proton magnetic resonance spectroscopy, diffusion-weighted imaging, and functional magnetic resonance imaging, provide a better approximation of the pathological substrate of the multiple sclerosis plaques, have increased our understanding of the pathogenesis of the disease, and have proven useful for studying the natural history of multiple sclerosis and monitoring the effects of new treatments. Therefore, magnetic resonance imaging not only plays an

  2. MR in the diagnosis and monitoring of multiple sclerosis: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, Alex [Magnetic Resonance Unit (I.D.I.), Department of Radiology, Hospital Universitari Vall d' Hebron, Barcelona (Spain)], E-mail: alex.rovira@idi-cat.org; Leon, Adelaida [Magnetic Resonance Unit (I.D.I.), Department of Radiology, Hospital Universitari Vall d' Hebron, Barcelona (Spain)

    2008-09-15

    Multiple sclerosis is a chronic, persistent inflammatory-demyelinating disease of the central nervous system that typically presents as an acute clinically isolated syndrome attributable to a monofocal or multifocal demyelinating lesion, which usually affects the optic nerve, spinal cord, or brainstem and cerebellum. Although the diagnosis of multiple sclerosis is still based on clinical findings, magnetic resonance imaging is now integrated in the overall diagnostic scheme of the disease because of its unique sensitivity to demonstrate the spatial and temporal dissemination of demyelinating plaques in the brain and spinal cord. Conventional magnetic resonance imaging techniques, such as T2-weighted and gadolinium-enhanced T1-weighted sequences are highly sensitive in detecting multiple sclerosis plaques and provide a quantitative assessment of inflammatory activity and lesion load. However, there is a persisting mismatch between clinical and magnetic resonance imaging efficacy of approved treatments, which underlies the fact that this technique does not suffice to explain the entire spectrum of the disease process. In recent years, great effort has been dedicated to overcoming these limitations by using non-conventional magnetic resonance-derived metrics that can selectively measure the more destructive aspects of multiple sclerosis pathology and monitor the reparative mechanisms. These metrics, which include unenhanced T1-weighted imaging, measures of central nervous system atrophy, magnetization transfer imaging, proton magnetic resonance spectroscopy, diffusion-weighted imaging, and functional magnetic resonance imaging, provide a better approximation of the pathological substrate of the multiple sclerosis plaques, have increased our understanding of the pathogenesis of the disease, and have proven useful for studying the natural history of multiple sclerosis and monitoring the effects of new treatments. Therefore, magnetic resonance imaging not only plays an

  3. Multiple reaction monitoring targeted LC-MS analysis of potential cell death marker proteins for increased bioprocess control.

    Science.gov (United States)

    Albrecht, Simone; Kaisermayer, Christian; Reinhart, David; Ambrose, Monica; Kunert, Renate; Lindeberg, Anna; Bones, Jonathan

    2018-05-01

    The monitoring of protein biomarkers for the early prediction of cell stress and death is a valuable tool for process characterization and efficient biomanufacturing control. A representative set of six proteins, namely GPDH, PRDX1, LGALS1, CFL1, TAGLN2 and MDH, which were identified in a previous CHO-K1 cell death model using discovery LC-MS E was translated into a targeted liquid chromatography multiple reaction monitoring mass spectrometry (LC-MRM-MS) platform and verified. The universality of the markers was confirmed in a cell growth model for which three Chinese hamster ovary host cell lines (CHO-K1, CHO-S, CHO-DG44) were grown in batch culture in two different types of basal media. LC-MRM-MS was also applied to spent media (n = 39) from four perfusion biomanufacturing series. Stable isotope-labelled peptide analogues and a stable isotope-labelled monoclonal antibody were used for improved protein quantitation and simultaneous monitoring of the workflow reproducibility. Significant increases in protein concentrations were observed for all viability marker proteins upon increased dead cell numbers and allowed for discrimination of spent media with dead cell densities below and above 1 × 10 6  dead cells/mL which highlights the potential of the selected viability marker proteins in bioprocess control. Graphical abstract Overview of the LC-MRM-MS workflow for the determination of proteomic markers in conditioned media from the bioreactor that correlate with CHO cell death.

  4. 40 CFR 75.82 - Monitoring of Hg mass emissions and heat input at common and multiple stacks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring of Hg mass emissions and... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Hg Mass Emission Provisions § 75.82 Monitoring of Hg mass emissions and heat input at common and multiple stacks. (a) Unit...

  5. Simultaneous analysis of carbohydrates and organic acids by HPLC-DAD-RI for monitoring goat's milk yogurts fermentation.

    Science.gov (United States)

    da Costa, Marion Pereira; Frasao, Beatriz da Silva; Lima, Bruno Reis Carneiro da Costa; Rodrigues, Bruna Leal; Conte Junior, Carlos Adam

    2016-05-15

    During yogurt manufacture, the lactose fermentation and organic acid production can be used to monitor the fermentation process by starter cultures and probiotic bacteria. In the present work, a simple, sensitive and reproducible high-performance liquid chromatography with dual detectors, diode array detector and refractive index was validated by simultaneous analysis of carbohydrates and organic acids in goat milk yogurts. In addition, pH and bacterial analysis were performed. Separation of all the compounds was performed on an Aminex HPX-87H column (300×7.8 mm, 9 µm) utilizing a 3 mmol L(-1) sulfuric acid aqueous mobile phase under isocratic conditions. Lactose, glucose, galactose, citric, lactic and formic acids were used to evaluate the following performance parameters: selectivity, linearity, precision, limit of detection (LOD), limit of quantification (LOQ), decision limits (CCα), detection capabilities (CCβ), recovery and robustness. For the method application a six goat milk yogurts were elaborated: natural, probiotic, prebiotic, symbiotic, cupuassu fruit pulp, and probiotic with cupuassu fruit pulp. The validated method presented an excellent selectivity with no significant matrix effect, and a broad linear study range with coefficients of determination higher than 0.995. The relative standard deviation was lower than 10% under repeatability and within-laboratory reproducibility conditions for the studied analytes. The LOD of the method was defined from 0.001 to 0.003 µg g(-1), and the LOQ from 0.003 to 0.013 µg g(-1). The CCα was ranged from 0.032 to 0.943 µg g(-1), and the CCβ from 0.053 to 1.604 µg g(-1). The obtained recovery values were from 78% to 119%. In addition, the method exhibited an appropriate robustness for all parameter evaluated. Base in our data, it was concluded that the performance parameters demonstrated total method adequacy for the detection and quantification of carbohydrates and organic acids in goat milk yogurts. The

  6. Online process monitoring at quasi-simultaneous laser transmission welding using a 3D-scanner with integrated pyrometer

    Science.gov (United States)

    Schmailzl, A.; Steger, S.; Dostalek, M.; Hierl, S.

    2016-03-01

    Quasi-simultaneous laser transmission welding is a well-known joining technique for thermoplastics and mainly used in the automotive as well as in the medical industry. For process control usually the so called set-path monitoring is used, where the weld is specified as "good" if the irradiation time is inside a defined confidence interval. However, the detection of small-sized gaps or thermal damaged zones is not possible with this technique. The analyzation of the weld seam temperature during welding offers the possibility to overcome this problem. In this approach a 3D-scanner is used instead of a scanner with flat-field optic. By using a pyrometer in combination with a 3D-scanner no color-corrected optic is needed in order to provide that laser- and detection-spot are concentric. Experimental studies on polyethylene T-joints have shown that the quality of the signal is adequate, despite the use of an optical setup with a long working distance and a small optical aperture. The effects on temperature are studied for defects like a gap in the joining zone. Therefore a notch was milled into the absorbent polymer. In case of producing housings for electronic parts the effect of an electrical wire between the joining partners is also investigated. Both defects can be identified by a local temperature deviation even at a feed rate of four meters per second. Furthermore a strategy for signal-processing is demonstrated. By this, remaining defects can be identified. Consequently an online detection of local defects is possible, which makes a dynamic process control feasible.

  7. Simultaneous micro-electromembrane extractions of anions and cations using multiple free liquid membranes and acceptor solutions

    Czech Academy of Sciences Publication Activity Database

    Kubáň, Pavel; Boček, Petr

    2016-01-01

    Roč. 908, FEB (2016), s. 113-120 ISSN 0003-2670 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : free liquid membranes * micro-electromembrane extraction * simultaneous extractions Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 4.950, year: 2016

  8. Simultaneous micro-electromembrane extractions of anions and cations using multiple free liquid membranes and acceptor solutions

    Czech Academy of Sciences Publication Activity Database

    Kubáň, Pavel; Boček, Petr

    2016-01-01

    Roč. 908, FEB (2016), s. 113-120 ISSN 0003-2670 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : free liquid membranes * micro-electromembrane extraction * simultaneous extractions Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.950, year: 2016

  9. High-Speed Monitoring of Multiple Grid-Connected Photovoltaic Array Configurations and Supplementary Weather Station.

    Science.gov (United States)

    Boyd, Matthew T

    2017-06-01

    Three grid-connected monocrystalline silicon photovoltaic arrays have been instrumented with research-grade sensors on the Gaithersburg, MD campus of the National Institute of Standards and Technology (NIST). These arrays range from 73 kW to 271 kW and have different tilts, orientations, and configurations. Irradiance, temperature, wind, and electrical measurements at the arrays are recorded, and images are taken of the arrays to monitor shading and capture any anomalies. A weather station has also been constructed that includes research-grade instrumentation to measure all standard meteorological quantities plus additional solar irradiance spectral bands, full spectrum curves, and directional components using multiple irradiance sensor technologies. Reference photovoltaic (PV) modules are also monitored to provide comprehensive baseline measurements for the PV arrays. Images of the whole sky are captured, along with images of the instrumentation and reference modules to document any obstructions or anomalies. Nearly, all measurements at the arrays and weather station are sampled and saved every 1s, with monitoring having started on Aug. 1, 2014. This report describes the instrumentation approach used to monitor the performance of these photovoltaic systems, measure the meteorological quantities, and acquire the images for use in PV performance and weather monitoring and computer model validation.

  10. Simultaneous statistical bias correction of multiplePM2.5 species from a regional photochemical grid model

    Science.gov (United States)

    In recent years environmental epidemiologists have begun utilizing regionalscale air quality computer models to predict ambient air pollution concentrations in health studies instead of or in addition to monitoring data from central sites. The advantages of using such models i...

  11. Non-targeted, high resolution mass spectrometry strategy for simultaneous monitoring of xenobiotics and endogenous compounds in green sea turtles on the Great Barrier Reef.

    Science.gov (United States)

    Heffernan, Amy L; Gómez-Ramos, Maria M; Gaus, Caroline; Vijayasarathy, Soumini; Bell, Ian; Hof, Christine; Mueller, Jochen F; Gómez-Ramos, Maria J

    2017-12-01

    Chemical contamination poses a threat to ecosystem, biota and human health, and identifying these hazards is a complex challenge. Traditional hazard identification relies on a priori-defined targets of limited chemical scope, and is generally inappropriate for exploratory studies such as explaining toxicological effects in environmental systems. Here we present a non-target high resolution mass spectrometry environmental monitoring study with multivariate statistical analysis to simultaneously detect biomarkers of exposure (e.g. xenobiotics) and biomarkers of effect in whole turtle blood. Borrowing the concept from clinical chemistry, a case-control sampling approach was used to investigate the potential influence of xenobiotics of anthropogenic origin on free-ranging green sea turtles (Chelonia mydas) from a remote, offshore 'control' site; and two coastal 'case' sites influenced by urban/industrial and agricultural activities, respectively, on the Great Barrier Reef in North Queensland, Australia. Multiple biomarkers of exposure, including sulfonic acids (n=9), a carbamate insecticide metabolite, and other industrial chemicals; and five biomarkers of effect (lipid peroxidation products), were detected in case sites. Additionally, two endogenous biomarkers of neuroinflammation and oxidative stress were identified, and showed moderate-to-strong correlations with clinical measures of inflammation and liver dysfunction. Our data filtering strategy overcomes limitations of traditional a priori selection of target compounds, and adds to the limited environmental xenobiotic metabolomics literature. To our knowledge this is the first case-control study of xenobiotics in marine megafauna, and demonstrates the utility of green sea turtles to link internal and external exposure, to explain potential toxicological effects in environmental systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A novel system for simultaneous or sequential integration of multiple gene-loading vectors into a defined site of a human artificial chromosome.

    Science.gov (United States)

    Suzuki, Teruhiko; Kazuki, Yasuhiro; Oshimura, Mitsuo; Hara, Takahiko

    2014-01-01

    Human artificial chromosomes (HACs) are gene-delivery vectors suitable for introducing large DNA fragments into mammalian cells. Although a HAC theoretically incorporates multiple gene expression cassettes of unlimited DNA size, its application has been limited because the conventional gene-loading system accepts only one gene-loading vector (GLV) into a HAC. We report a novel method for the simultaneous or sequential integration of multiple GLVs into a HAC vector (designated as the SIM system) via combined usage of Cre, FLP, Bxb1, and φC31 recombinase/integrase. As a proof of principle, we first attempted simultaneous integration of three GLVs encoding EGFP, Venus, and TdTomato into a gene-loading site of a HAC in CHO cells. These cells successfully expressed all three fluorescent proteins. Furthermore, microcell-mediated transfer of HACs enabled the expression of those fluorescent proteins in recipient cells. We next demonstrated that GLVs could be introduced into a HAC one-by-one via reciprocal usage of recombinase/integrase. Lastly, we introduced a fourth GLV into a HAC after simultaneous integration of three GLVs by FLP-mediated DNA recombination. The SIM system expands the applicability of HAC vectors and is useful for various biomedical studies, including cell reprogramming.

  13. A novel system for simultaneous or sequential integration of multiple gene-loading vectors into a defined site of a human artificial chromosome.

    Directory of Open Access Journals (Sweden)

    Teruhiko Suzuki

    Full Text Available Human artificial chromosomes (HACs are gene-delivery vectors suitable for introducing large DNA fragments into mammalian cells. Although a HAC theoretically incorporates multiple gene expression cassettes of unlimited DNA size, its application has been limited because the conventional gene-loading system accepts only one gene-loading vector (GLV into a HAC. We report a novel method for the simultaneous or sequential integration of multiple GLVs into a HAC vector (designated as the SIM system via combined usage of Cre, FLP, Bxb1, and φC31 recombinase/integrase. As a proof of principle, we first attempted simultaneous integration of three GLVs encoding EGFP, Venus, and TdTomato into a gene-loading site of a HAC in CHO cells. These cells successfully expressed all three fluorescent proteins. Furthermore, microcell-mediated transfer of HACs enabled the expression of those fluorescent proteins in recipient cells. We next demonstrated that GLVs could be introduced into a HAC one-by-one via reciprocal usage of recombinase/integrase. Lastly, we introduced a fourth GLV into a HAC after simultaneous integration of three GLVs by FLP-mediated DNA recombination. The SIM system expands the applicability of HAC vectors and is useful for various biomedical studies, including cell reprogramming.

  14. Facile LC-UV methods for simultaneous monitoring of ciprofloxacin and rosuvastatin in API, formulations and human serum.

    Science.gov (United States)

    Arayne, M Saeed; Sultana, Najma; Tabassum, Arman

    2015-02-01

    An efficient, selective and cost-effective liquid chromatographic assay was developed and validated for the simultaneous quantification of ciprofloxacin and rosuvastatin in Active Pharmaceutical Ingredients (API), pharmaceutical formulations and in human serum. The chromatographic system consisted of mobile phase methanol-water, 90:10 v/v at pH 3.0 adjusted with o-phosphoric acid, pumped at 1.0 mL/min through a prepacked Purospher Star C18 (5 µm, 25 × 0.46 cm) column and effluent was monitored at the isosbestic point (255 nm) as well as at the λmax of individual drugs (243 and 271 nm). The method was validated over a linear concentration range of 0.25-15 µg/mL for ciprofloxacin and 0.33-20 µg/mL for rosuvastatin (r(2)  ≥ 0.999). The ranges of reliable response (limits of detection and quantitation) for ciprofloxacin were 3-15 and 9-45 ng/mL and 17-29 and 52-88 ng/mL, respectively, for rosuvastatin in all API, pharmaceutical formulations and human serum. Analytical recovery from human serum was >98% and relative standard deviation (RSD) was <2. The accuracies were 97.13-102.55 and 97.41-101.31% and precisions in RSD were 0.04-1.90 and 0.02-1.23% for ciprofloxacin and rosuvastatin, respectively. No matrix interferences, ion suppression/enhancement and carry-over were detected. The total assay run time was less than 5 min. In another study, for optimum performance the detector was programmed for multiwavelength scanning at the absorption maxima of each component. Consequently, the linearity range was improved and limit of detection and quantitation values were down to 1-4 and 4-12 ng/mL for ciprofloxacin and 3-5 and 9-15 ng/mL for rosuvastatin, respectively. The validation parameters fitted ICH guidelines through the isosbestic and individual λmax approach. The small sample volume and simplicity of preparation make this method suitable for use in human serum samples, pharmaceutical formulations, quality control, drug

  15. Use of rocuronium and sugammadex under neuromuscular transmission monitoring in a patient with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Chryssoula Staikou

    2017-01-01

    Full Text Available Multiple sclerosis (MS is a potentially disabling disease characterized by demyelinating lesions in the central nervous system. One of the anesthetic challenges encountered in surgical patients with MS is the management of neuromuscular blockade (NMB and its reversal. We report a case of a 31-year-old female patient suffering from MS, who underwent gynecological surgery under general anesthesia with sevoflurane, fentanyl, and rocuronium which was successfully reversed with sugammadex. Neuromuscular transmission (NMT monitoring was used to guide the intraoperative doses of rocuronium and also the reversal of NMB by the use of sugammadex to ensure a safe tracheal extubation. In addition, delivered volatile was titrated according to anesthetic depth monitoring (Bispectral Index while esophageal temperature was also monitored for the maintenance of normothermia. Postoperatively, a multimodal analgesic scheme offered a high-quality analgesia and sleep, minimization of anxiety, and increased patient satisfaction. At 1-month follow-up, the patient's course was uncomplicated without any MS exacerbation. We consider that the use of rocuronium and sugammadex under NMT monitoring may represent a useful and safe choice in patients with MS.

  16. Assessing interactions among multiple physiological systems during walking outside a laboratory: An Android based gait monitor

    Science.gov (United States)

    Sejdić, E.; Millecamps, A.; Teoli, J.; Rothfuss, M. A.; Franconi, N. G.; Perera, S.; Jones, A. K.; Brach, J. S.; Mickle, M. H.

    2015-01-01

    Gait function is traditionally assessed using well-lit, unobstructed walkways with minimal distractions. In patients with subclinical physiological abnormalities, these conditions may not provide enough stress on their ability to adapt to walking. The introduction of challenging walking conditions in gait can induce responses in physiological systems in addition to the locomotor system. There is a need for a device that is capable of monitoring multiple physiological systems in various walking conditions. To address this need, an Android-based gait-monitoring device was developed that enabled the recording of a patient's physiological systems during walking. The gait-monitoring device was tested during self-regulated overground walking sessions of fifteen healthy subjects that included 6 females and 9 males aged 18 to 35 years. The gait-monitoring device measures the patient's stride interval, acceleration, electrocardiogram, skin conductance and respiratory rate. The data is stored on an Android phone and is analyzed offline through the extraction of features in the time, frequency and time-frequency domains. The analysis of the data depicted multisystem physiological interactions during overground walking in healthy subjects. These interactions included locomotion-electrodermal, locomotion-respiratory and cardiolocomotion couplings. The current results depicting strong interactions between the locomotion system and the other considered systems (i.e., electrodermal, respiratory and cardivascular systems) warrant further investigation into multisystem interactions during walking, particularly in challenging walking conditions with older adults. PMID:26390946

  17. Using Bayesian Belief Networks To Assess Volcano State from Multiple Monitoring Timeseries And Other Evidence

    Science.gov (United States)

    Odbert, Henry; Aspinall, Willy

    2013-04-01

    When volcanoes exhibit unrest or become eruptively active, science-based decision support invariably is sought by civil authorities. Evidence available to scientists about a volcano's internal state is usually indirect, secondary or very nebulous.Advancement of volcano monitoring technology in recent decades has increased the variety and resolution of multi-parameter timeseries data recorded at volcanoes. Monitoring timeseries may be interpreted in real time by observatory staff and are often later subjected to further analytic scrutiny by the research community at large. With increasing variety and resolution of data, interpreting these multiple strands of parallel, partial evidence has become increasingly complex. In practice, interpretation of many timeseries involves familiarity with the idiosyncracies of the volcano, the monitoring techniques, the configuration of the recording instrumentation, observations from other datasets, and so on. Assimilation of this knowledge is necessary in order to select and apply the appropriate statistical techniques required to extract the required information. Bayesian Belief Networks (BBNs) use probability theory to treat and evaluate uncertainties in a rational and auditable scientific manner, but only to the extent warranted by the strength of the available evidence. The concept is a suitable framework for marshalling multiple observations, model results and interpretations - and associated uncertainties - in a methodical manner. The formulation is usually implemented in graphical form and could be developed as a tool for near real-time, ongoing use in a volcano observatory, for example. We explore the application of BBNs in analysing volcanic timeseries, the certainty with which inferences may be drawn, and how they can be updated dynamically. Such approaches provide a route to developing analytical interface(s) between volcano monitoring analyses and probabilistic hazard analysis. We discuss the use of BBNs in hazard

  18. MR Imaging in Monitoring and Predicting Treatment Response in Multiple Sclerosis.

    Science.gov (United States)

    Río, Jordi; Auger, Cristina; Rovira, Àlex

    2017-05-01

    MR imaging is the most sensitive tool for identifying lesions in patients with multiple sclerosis (MS). MR imaging has also acquired an essential role in the detection of complications arising from these treatments and in the assessment and prediction of efficacy. In the future, other radiological measures that have shown prognostic value may be incorporated within the models for predicting treatment response. This article examines the role of MR imaging as a prognostic tool in patients with MS and the recommendations that have been proposed in recent years to monitor patients who are treated with disease-modifying drugs. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Monitoring the Lavina di Roncovetro (RE, Italy) landslide by integrating traditional monitoring systems and multiple high-resolution topographic datasets

    Science.gov (United States)

    Fornaciai, Alessandro; Favalli, Massimiliano; Gigli, Giovanni; Nannipieri, Luca; Mucchi, Lorenzo; Intieri, Emanuele; Agostini, Andrea; Pizziolo, Marco; Bertolini, Giovanni; Trippi, Federico; Casagli, Nicola; Schina, Rosa; Carnevale, Ennio

    2016-04-01

    Roncovetro Landslide were generated at different times. The 3D models are then georeferenced and the digital elevation models (DEMs) created. By comparing the obtained DEMs, changes in the investigated area were detected and the sediment volumes, as well as the 3D displacement at the most active parts of the landslide quantified. In this work, we test the performance of the SFM techniques applied on active landslide by comparing them with the traditional monitoring systems, highlighting the strengths and weaknesses of both methods. In addition, we show the preliminary results obtained integrating the traditional monitoring systems and the multiple high-resolution topographic datasets, over a period of more than one year, used for investigating the spatial and the temporal evolution of the upper sector of the Roncovetro landslide.

  20. Exploiting off-targeting in guide-RNAs for CRISPR systems for simultaneous editing of multiple genes

    DEFF Research Database (Denmark)

    Ferreira, Raphael; Gatto, Francesco; Nielsen, Jens

    2017-01-01

    Bioinformatics tools to design guide-RNAs (gRNAs) in Clustered Regularly Interspaced Short Palindromic Repeats systems mostly focused on minimizing off-targeting to enhance efficacy of genome editing. However, there are circumstances in which off-targeting might be desirable to target multiple ge...

  1. CRISPR/Cas9 : A molecular Swiss army knife for simultaneous introduction of multiple genetic modifications in Saccharomyces cerevisiae

    NARCIS (Netherlands)

    Mans, R.; Van Rossum, H.M.; Wijsman, M.; Backx, A.; Kuijpers, N.G.A.; van den Broek, M.; Daran-Lapujade, P.A.S.; Pronk, J.T.; Van Maris, A.J.A.; Daran, J.G.

    2015-01-01

    A variety of techniques for strain engineering in Saccharomyces cerevisiae have recently been developed. However, especially when multiple genetic manipulations are required, strain construction is still a time-consuming process. This study describes new CRISPR/Cas9-based approaches for easy, fast

  2. Multiple functional attributes of glucose-monitoring neurons in the medial orbitofrontal (ventrolateral prefrontal) cortex.

    Science.gov (United States)

    Szabó, István; Hormay, Edina; Csetényi, Bettina; Nagy, Bernadett; Lénárd, László; Karádi, Zoltán

    2018-02-01

    Multiple functional attributes of glucose-monitoring neurons in the medial orbitofrontal (ventrolateral prefrontal) cortex. NEUROSCI BIOBEHAV REV 73(1) XXX-XXX, 2017.- Special chemosensory cells, the glucose-monitoring (GM) neurons, reportedly involved in the central feeding control, exist in the medial orbitofrontal (ventrolateral prefrontal) cortex (mVLPFC). Electrophysiological, metabolic and behavioral studies reveal complex functional attributes of these cells and raise their homeostatic significance. Single neuron recordings, by means of the multibarreled microelectrophoretic technique, elucidate differential sensitivities of limbic forebrain neurons in the rat and the rhesus monkey to glucose and other chemicals, whereas gustatory stimulations demonstrate their distinct taste responsiveness. Metabolic examinations provide evidence for alteration of blood glucose level in glucose tolerance test and elevation of plasma triglyceride concentration after destruction of the local GM cells by streptozotocin (STZ). In behavioral studies, STZ microinjection into the mVLPFC fails to interfere with the acquisition of saccharin conditioned taste avoidance, does cause, however, taste perception deficit in taste reactivity tests. Multiple functional attributes of GM neurons in the mVLPFC, within the frame of the hierarchically organized central GM neuronal network, appear to play important role in the maintenance of the homeostatic balance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Simultaneous analysis of multiple classes of antimicrobials in environmental water samples using SPE coupled with UHPLC-ESI-MS/MS and isotope dilution.

    Science.gov (United States)

    Tran, Ngoc Han; Chen, Hongjie; Do, Thanh Van; Reinhard, Martin; Ngo, Huu Hao; He, Yiliang; Gin, Karina Yew-Hoong

    2016-10-01

    A robust and sensitive analytical method was developed for the simultaneous analysis of 21 target antimicrobials in different environmental water samples. Both single SPE and tandem SPE cartridge systems were investigated to simultaneously extract multiple classes of antimicrobials. Experimental results showed that good extraction efficiencies (84.5-105.6%) were observed for the vast majority of the target analytes when extraction was performed using the tandem SPE cartridge (SB+HR-X) system under an extraction pH of 3.0. HPLC-MS/MS parameters were optimized for simultaneous analysis of all the target analytes in a single injection. Quantification of target antimicrobials in water samples was accomplished using 15 isotopically labeled internal standards (ILISs), which allowed the efficient compensation of the losses of target analytes during sample preparation and correction of matrix effects during UHPLC-MS/MS as well as instrument fluctuations in MS/MS signal intensity. Method quantification limit (MQL) for most target analytes based on SPE was below 5ng/L for surface waters, 10ng/L for treated wastewater effluents, and 15ng/L for raw wastewater. The method was successfully applied to detect and quantify the occurrence of the target analytes in raw influent, treated effluent and surface water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A low-cost, high-performance, digital signal processor-based lock-in amplifier capable of measuring multiple frequency sweeps simultaneously

    International Nuclear Information System (INIS)

    Sonnaillon, Maximiliano Osvaldo; Bonetto, Fabian Jose

    2005-01-01

    A high-performance digital lock-in amplifier implemented in a low-cost digital signal processor (DSP) board is described. This lock in is capable of measuring simultaneously multiple frequencies that change in time as frequency sweeps (chirps). The used 32-bit DSP has enough computing power to generate N=3 simultaneous reference signals and accurately measure the N=3 responses, operating as three lock ins connected in parallel to a linear system. The lock in stores the measured values in memory until they are downloaded to the a personal computer (PC). The lock in works in stand-alone mode and can be programmed and configured through the PC serial port. Downsampling and multiple filter stages were used in order to obtain a sharp roll off and a long time constant in the filters. This makes measurements possible in presence of high-noise levels. Before each measurement, the lock in performs an autocalibration that measures the frequency response of analog output and input circuitry in order to compensate for the departure from ideal operation. Improvements from previous lock-in implementations allow measuring the frequency response of a system in a short time. Furthermore, the proposed implementation can measure how the frequency response changes with time, a characteristic that is very important in our biotechnological application. The number of simultaneous components that the lock in can generate and measure can be extended, without reprogramming, by only using other DSPs of the same family that are code compatible and work at higher clock frequencies

  5. A low-cost, high-performance, digital signal processor-based lock-in amplifier capable of measuring multiple frequency sweeps simultaneously

    Energy Technology Data Exchange (ETDEWEB)

    Sonnaillon, Maximiliano Osvaldo; Bonetto, Fabian Jose [Laboratorio de Cavitacion y Biotecnologia, San Carlos de Bariloche (8400) (Argentina)

    2005-02-01

    A high-performance digital lock-in amplifier implemented in a low-cost digital signal processor (DSP) board is described. This lock in is capable of measuring simultaneously multiple frequencies that change in time as frequency sweeps (chirps). The used 32-bit DSP has enough computing power to generate N=3 simultaneous reference signals and accurately measure the N=3 responses, operating as three lock ins connected in parallel to a linear system. The lock in stores the measured values in memory until they are downloaded to the a personal computer (PC). The lock in works in stand-alone mode and can be programmed and configured through the PC serial port. Downsampling and multiple filter stages were used in order to obtain a sharp roll off and a long time constant in the filters. This makes measurements possible in presence of high-noise levels. Before each measurement, the lock in performs an autocalibration that measures the frequency response of analog output and input circuitry in order to compensate for the departure from ideal operation. Improvements from previous lock-in implementations allow measuring the frequency response of a system in a short time. Furthermore, the proposed implementation can measure how the frequency response changes with time, a characteristic that is very important in our biotechnological application. The number of simultaneous components that the lock in can generate and measure can be extended, without reprogramming, by only using other DSPs of the same family that are code compatible and work at higher clock frequencies.

  6. Monolithically integrated biophotonic lab-on-a-chip for cell culture and simultaneous pH monitoring

    NARCIS (Netherlands)

    Munoz-Berbel, Xavier; Rodriguez-Rodriguez, Rosalia; Vigues, Nuria; Demming, Stefanie; Mas, Jordi; Buettgenbach, Stephanus; Verpoorte, Elisabeth; Ortiz, Pedro; Llobera, Andreu

    2013-01-01

    A poly(dimethylsiloxane) biophotonic lab-on-a-chip (bioPhLoC) containing two chambers, an incubation chamber and a monitoring chamber for cell retention/proliferation and pH monitoring, respectively, is presented. The bioPhLoC monolithically integrates a filter with 3 mu m high size-exclusion

  7. Grouping and the pitch of a mistuned fundamental component: Effects of applying simultaneous multiple mistunings to the other harmonics.

    Science.gov (United States)

    Roberts, Brian; Holmes, Stephen D

    2006-12-01

    Mistuning a harmonic produces an exaggerated change in its pitch. This occurs because the component becomes inconsistent with the regular pattern that causes the other harmonics (constituting the spectral frame) to integrate perceptually. These pitch shifts were measured when the fundamental (F0) component of a complex tone (nominal F0 frequency = 200 Hz) was mistuned by +8% and -8%. The pitch-shift gradient was defined as the difference between these values and its magnitude was used as a measure of frame integration. An independent and random perturbation (spectral jitter) was applied simultaneously to most or all of the frame components. The gradient magnitude declined gradually as the degree of jitter increased from 0% to +/-40% of F0. The component adjacent to the mistuned target made the largest contribution to the gradient, but more distant components also contributed. The stimuli were passed through an auditory model, and the exponential height of the F0-period peak in the averaged summary autocorrelation function correlated well with the gradient magnitude. The fit improved when the weighting on more distant channels was attenuated by a factor of three per octave. The results are consistent with a grouping mechanism that computes a weighted average of periodicity strength across several components.

  8. Simultaneous application of multiple platforms (Glider, Scanfish, profiling mooring, CTD) to improve detection and quantification of temporal ocean dynamics

    Science.gov (United States)

    Meyer, D.; Prien, R. D.; Lips, U.; Naumann, M.; Liblik, T.; Schulz-Bull, D. E.

    2016-02-01

    Ocean dynamics are difficult to observe given the broad spectrum of temporal and spatial scales. Robotic technology can be used to address this issue, and help to investigate the variability of physical and biogeochemical processes. This work focuses on ocean robots and in particular on glider technology which seems to be one of the most promising oceanographic tools for future marine research. In this context, we present the results of an observational program conducted in the Baltic Sea combining a profiling mooring (GODESS - Gotland Deep Environmental Sampling Station) and glider technology (Slocum). The temporal variability is captured by the mooring, while the spatial variability is obtained from the glider sampling the surrounding area. Furthermore, classical CTD-measurements and an underwater vehicle (Scanfish) are used simultaneously by two different research vessels to validate and complement the observing network. The main aim of the study is to identify possible synergies between the different platforms and to get a better understanding of maximizing the information content of the data collected by this network. The value and the quality of the data of each individual platform is analyzed and their contribution to the performance of the network itself evaluated.

  9. Using multiple PCR and CE with chemiluminescence detection for simultaneous qualitative and quantitative analysis of genetically modified organism.

    Science.gov (United States)

    Guo, Longhua; Qiu, Bin; Chi, Yuwu; Chen, Guonan

    2008-09-01

    In this paper, an ultrasensitive CE-CL detection system coupled with a novel double-on-column coaxial flow detection interface was developed for the detection of PCR products. A reliable procedure based on this system had been demonstrated for qualitative and quantitative analysis of genetically modified organism-the detection of Roundup Ready Soy (RRS) samples was presented as an example. The promoter, terminator, function and two reference genes of RRS were amplified with multiplex PCR simultaneously. After that, the multiplex PCR products were labeled with acridinium ester at the 5'-terminal through an amino modification and then analyzed by the proposed CE-CL system. Reproducibility of analysis times and peak heights for the CE-CL analysis were determined to be better than 0.91 and 3.07% (RSD, n=15), respectively, for three consecutive days. It was shown that this method could accurately and qualitatively detect RRS standards and the simulative samples. The evaluation in terms of quantitative analysis of RRS provided by this new method was confirmed by comparing our assay results with those of the standard real-time quantitative PCR (RT-QPCR) using SYBR Green I dyes. The results showed a good coherence between the two methods. This approach demonstrated the possibility for accurate qualitative and quantitative detection of GM plants in a single run.

  10. Quantification of methionine and selenomethionine in biological samples using multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS).

    Science.gov (United States)

    Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel

    2018-05-01

    Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.

  11. Simultaneous quantitative determination of multiple bioactive markers in Ocimum sanctum obtained from different locations and its marketed herbal formulations using UPLC-ESI-MS/MS combined with principal component analysis.

    Science.gov (United States)

    Pandey, Renu; Chandra, Preeti; Srivastava, Mukesh; Mishra, D K; Kumar, Brijesh

    2015-01-01

    Ocimum sanctum L., with phenolic acids, flavonoids, propenyl phenols and terpenoids as active pharmacological constituents, is a popular medicinal herb and is present as an ingredient in many herbal formulations. Therefore, development of a reliable analytical method for simultaneous determination of the pharmacologically active constituents of O. sanctum is of high importance. To develop and validate a new, rapid, sensitive and selective UPLC-ESI/MS/MS method for simultaneous determination of 23 bioactive markers including phenolic acids, flavonoids, propenyl phenol and terpenoid in the leaf extract and marketed herbal formulations of O. sanctum. An UPLC-ESI/MS/MS method using negative electrospray ionisation (ESI) in multiple-reaction-monitoring (MRM) mode was used for simultaneous determination. Chromatographic separation was achieved on an Acquity UPLC BEH C18 -column using a gradient elution with 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Principal component analysis (PCA) was applied to correlate and discriminate eight geographical collections of O. sanctum based on quantitative data of the analytes. The developed method was validated as per International Conference on Harmonization guidelines and found to be accurate, with overall recovery in the range 95.09-104.84% (RSD ≤ 1.85%), precise (RSD ≤ 1.98%) and linear (r(2)  ≥ 0.9971) over the concentration range of 0.5-1000 ng/mL. Ursolic acid was found to be the most abundant marker in all the samples investigated, except for the marketed tablet. The method established is simple, rapid and sensitive, hence it can be reliably utilised for the quality control of O. sanctum and derived herbal formulations. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Capillary gel electrophoresis-coupled aptamer enzymatic cleavage protection strategy for the simultaneous detection of multiple small analytes.

    Science.gov (United States)

    Perrier, Sandrine; Zhu, Zhenyu; Fiore, Emmanuelle; Ravelet, Corinne; Guieu, Valérie; Peyrin, Eric

    2014-05-06

    This novel, multi small-analyte sensing strategy is the result of combining the target-induced aptamer enzymatic protection approach with the CGE-LIF (capillary gel electrophoresis with laser-induced fluorescence) technique. The implemented assay principle is based on an analysis of the phosphodiesterase I (PDE I)-mediated size variation of a fluorescein-labeled aptamer (FApt), the enzyme catalyzing the removal of nucleotides from DNA in the 3' to 5' direction. In the absence of the target, the unfolded aptamer was enzymatically cleaved into short DNA fragments. Upon target binding, the DNA substrate was partially protected against enzymatic hydrolysis. The amount of bound aptamer remaining after the exonuclease reaction was proportional to the concentration of the target. The CGE technique, which was used to determine the separation of FApt species from DNA digested products, permitted the quantification of adenosine (A), ochratoxin A (O), and tyrosinamide (T) under the same optimized enzymatic conditions. This assay strategy was subsequently applied to the simultaneous detection of A, O, and T in a single capillary under buffered conditions using corresponding FApt probes of different lengths (23, 36, and 49 nucleotides, respectively). Additionally, the detection of these three small molecules was successfully achieved in a complex medium (diluted, heat-treated human serum) showing a good recovery. It is worth noting that the multiplexed analysis was accomplished for targets with different charge states by using aptamers possessing various structural features. This sensing platform constitutes a rationalized and reliable approach with an expanded potential for a high-throughput determination of small analytes in a single capillary.

  13. Effects of a web-based tailored multiple-lifestyle intervention for adults: a two-year randomized controlled trial comparing sequential and simultaneous delivery modes.

    Science.gov (United States)

    Schulz, Daniela N; Kremers, Stef P J; Vandelanotte, Corneel; van Adrichem, Mathieu J G; Schneider, Francine; Candel, Math J J M; de Vries, Hein

    2014-01-27

    Web-based computer-tailored interventions for multiple health behaviors can have a significant public health impact. Yet, few randomized controlled trials have tested this assumption. The objective of this paper was to test the effects of a sequential and simultaneous Web-based tailored intervention on multiple lifestyle behaviors. A randomized controlled trial was conducted with 3 tailoring conditions (ie, sequential, simultaneous, and control conditions) in the Netherlands in 2009-2012. Follow-up measurements took place after 12 and 24 months. The intervention content was based on the I-Change model. In a health risk appraisal, all respondents (N=5055) received feedback on their lifestyle behaviors that indicated whether they complied with the Dutch guidelines for physical activity, vegetable consumption, fruit consumption, alcohol intake, and smoking. Participants in the sequential (n=1736) and simultaneous (n=1638) conditions received tailored motivational feedback to change unhealthy behaviors one at a time (sequential) or all at the same time (simultaneous). Mixed model analyses were performed as primary analyses; regression analyses were done as sensitivity analyses. An overall risk score was used as outcome measure, then effects on the 5 individual lifestyle behaviors were assessed and a process evaluation was performed regarding exposure to and appreciation of the intervention. Both tailoring strategies were associated with small self-reported behavioral changes. The sequential condition had the most significant effects compared to the control condition after 12 months (T1, effect size=0.28). After 24 months (T2), the simultaneous condition was most effective (effect size=0.18). All 5 individual lifestyle behaviors changed over time, but few effects differed significantly between the conditions. At both follow-ups, the sequential condition had significant changes in smoking abstinence compared to the simultaneous condition (T1 effect size=0.31; T2 effect

  14. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, Damodar, E-mail: dpokhrel@kumc.edu; Sood, Sumit; McClinton, Christopher; Shen, Xinglei; Lominska, Christopher; Saleh, Habeeb; Badkul, Rajeev; Jiang, Hongyu; Mitchell, Melissa; Wang, Fen

    2016-01-01

    Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5

  15. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

    International Nuclear Information System (INIS)

    Pokhrel, Damodar; Sood, Sumit; McClinton, Christopher; Shen, Xinglei; Lominska, Christopher; Saleh, Habeeb; Badkul, Rajeev; Jiang, Hongyu; Mitchell, Melissa; Wang, Fen

    2016-01-01

    Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D 2% , D 98% , and V 30 Gy NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing

  16. Rapid identification and simultaneous analysis of multiple constituents from Rheum tanguticum Maxim. ex Balf. by UPLC/Q-TOF-MS.

    Science.gov (United States)

    Gao, Liang-Liang; Guo, Tao; Xu, Xu-Dong; Yang, Jun-Shan

    2017-07-01

    Rhubarb contains biologically active compounds such as anthraquinones, anthrones, stilbenes and tannins. A rapid and efficient UPLC/Q-TOF-MS/MS method was developed and applied towards identifying the constituents of Rheum tanguticum Maxim. ex Balf. for the first time. Chemical constituents were separated and investigated by UPLC/Q-TOF-MS/MS in the negative ion mode. The ESI-MS 2 fragmentation pathways of four types of compounds were interpreted, providing a very useful guidance for the characterisation of different types of compounds. Based on the exact mass information, fragmentation characteristic and LC retention time of 7 reference standards, 30 constituents were tentatively identified from the methanol extract of R. tanguticum. Among them, seven compounds were described for the first time from R. tanguticum and two from the genus Rheum were described for the first time. The analytical tool used here is valuable for the rapid separation and identification of multiple and minor constituents in methanol extracts of R. tanguticum.

  17. San Diego Multiple Species Conservation Program (MSCP) Rare Plant Monitoring Review and Revision

    Science.gov (United States)

    McEachern, Kathryn; Pavlik, Bruce M.; Rebman, Jon; Sutter, Rob

    2007-01-01

    Introduction The San Diego Multiple Species Conservation Program (MSCP) was developed for the conservation of plants and animals in the south part of San Diego County, under the California Natural Community Conservation Planning Act of 1991 (California Department of Fish and Game) and the Federal Endangered Species Act of 1973, as amended (16 U.S. Code 1531-1544.) The Program is on the leading edge of conservation, as it seeks to both guide development and conserve at-risk species with the oversight of both State and Federal agencies. Lands were identified for inclusion in the MSCP based on their value as habitat for at-risk plants or plant communities (Natural Community Conservation Planning, 2005). Since its inception in the mid-1990s the Program has protected over 100,000 acres, involving 15 jurisdictions and the U.S. Fish and Wildlife Service (USFWS) and California Department of Fish and Game (CDFG) in the conservation of 87 taxa. Surveys for covered species have been conducted, and management and monitoring have been implemented at some high priority sites. Each jurisdiction or agency manages and monitors their conservation areas independently, while collaborating regionally for long-term protection. The San Diego MSCP is on the forefront of conservation, in one of the most rapidly growing urban areas of the country. The planning effort that developed the MSCP was state-of-the-art, using expert knowledge, spatial habitat modeling, and principles of preserve design to identify and prioritize areas for protection. Land acquisition and protection are ahead of schedule for most jurisdictions. Surveys have verified the locations of many rare plant populations known from earlier collections, and they provide general information on population size and health useful for further conservation planning. Management plans have been written or are in development for most MSCP parcels under jurisdictional control. Several agencies are developing databases for implementation

  18. Simultaneous monitoring of singlet and triplet exciton variations in solid organic semiconductors driven by an external static magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Baofu, E-mail: b.ding@ecu.edu.au; Alameh, Kamal, E-mail: k.alameh@ecu.edu.au [Electron Science Research Institute, Edith Cowan University, 270 Joondalup Drive, Joondalup, WA 6027 (Australia)

    2014-07-07

    The research field of organic spintronics has remarkably and rapidly become a promising research area for delivering a range of high-performance devices, such as magnetic-field sensors, spin valves, and magnetically modulated organic light emitting devices (OLEDs). Plenty of microscopic physical and chemical models based on exciton or charge interactions have been proposed to explain organic magneto-optoelectronic phenomena. However, the simultaneous observation of singlet- and triplet-exciton variations in an external magnetic field is still unfeasible, preventing a thorough theoretical description of the spin dynamics in organic semiconductors. Here, we show that we can simultaneously observe variations of singlet excitons and triplet excitons in an external magnetic field, by designing an OLED structure employing a singlet-exciton filtering and detection layer in conjunction with a separate triplet-exciton detection layer. This OLED structure enables the observation of a Lorentzian and a non-Lorentzian line-shape magnetoresponse for singlet excitons and triplet excitons, respectively.

  19. Simultaneous monitoring of singlet and triplet exciton variations in solid organic semiconductors driven by an external static magnetic field

    International Nuclear Information System (INIS)

    Ding, Baofu; Alameh, Kamal

    2014-01-01

    The research field of organic spintronics has remarkably and rapidly become a promising research area for delivering a range of high-performance devices, such as magnetic-field sensors, spin valves, and magnetically modulated organic light emitting devices (OLEDs). Plenty of microscopic physical and chemical models based on exciton or charge interactions have been proposed to explain organic magneto-optoelectronic phenomena. However, the simultaneous observation of singlet- and triplet-exciton variations in an external magnetic field is still unfeasible, preventing a thorough theoretical description of the spin dynamics in organic semiconductors. Here, we show that we can simultaneously observe variations of singlet excitons and triplet excitons in an external magnetic field, by designing an OLED structure employing a singlet-exciton filtering and detection layer in conjunction with a separate triplet-exciton detection layer. This OLED structure enables the observation of a Lorentzian and a non-Lorentzian line-shape magnetoresponse for singlet excitons and triplet excitons, respectively.

  20. Simultaneously combining AOD and multiple trace gas measurements to identify decadal changes in urban and biomass burning aerosols

    Science.gov (United States)

    Cohen, Jason

    2017-04-01

    This work presents a methodology by which to comprehensively analyze simultaneous tropospheric measurements of AOD and associated trace gasses. It then applies this methodology by focusing over the past 11 years (2006-2016) on one of the most rapidly changing regions of the troposphere: Eastern and Southeastern Asia. The specific work presented incorporates measurements of both aerosol and related gas phase tropospheric measurements across different spectral, spatial, temporal, and passive/active sensors and properties, including: MODIS, MISR, OMI, CALIOP, and others. This new characterization reveals a trio of new information, including a time-invariant urban signal, slowly-time-varying new-urbanization signal, and a rapidly time-varying biomass burning signal. Additionally, due to the different chemical properties of the various species analyzed, analyzing the different spatial domains of the resulting products allows for further information in terms of the amounts of aerosols produced both through primary emissions as well as secondary processing. The end result is a new characterization, in space, time, and magnitude, of both anthropogenic and biomass burning aerosols. These results are then used to drive an advanced modeling system including aerosol chemistry, physics, optics, and transport, and employing an aerosol routine based on multi-modal and both externally mixed and core-shell mixing. The resulting characterization in space, time, and quantity is analyzed and compared against AERONET, NOAA, and other ground networks, with the results comparing consistently to or better than present approaches which set up net emissions separately from urban and biomass burning products. Scientifically, new source regions of emissions are identified, some of which were previously non-urbanized or found to not contain any fire hotspots. This new approach is consistent with the underlying economic and development pathways of expanding urban areas and rapid economic growth

  1. Reducing alarms and prioritising interventions in pig production by simultaneous monitoring of water consumption in multiple pens

    DEFF Research Database (Denmark)

    Dominiak, Katarina Nielsen; Hindsborg, Jeff; Pedersen, L. J.

    to be generated at pen level or merged at section or herd level to reduce the number of alarms. Information on which specific pens or sections are of higher risk of stress or diseases is communicated to the farmer and target work effort to pens at risk. For Herd A, all model parameters defined at section level...... resulted in the best fit (MSE =13.85 litres2/hour). For Herd B, parameters defined at both pen and section level resulted in the best fit (MSE = 1.47 litres2/hour). For both Herd A and Herd B, preliminary results support the spatial approach by generating a reduced number of alarms when comparing section...

  2. Simultaneous screening and confirmation of multiple classes of drug residues in fish by liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Smith, Shani; Gieseker, Charles; Reimschuessel, Renate; Decker, Christie-Sue; Carson, Mary C

    2009-11-13

    LC-ion trap mass spectrometry was used to screen and confirm 38 compounds from a variety of drug classes in four species of fish: trout, salmon, catfish, and tilapia. Samples were extracted with acetonitrile and hexane. The acetonitrile phase was evaporated, redissolved in water and acetonitrile, and analyzed by gradient chromatography on a phenyl column. MS(2) or MS(3) spectra were monitored for each compound. Qualitative method performance was evaluated by the analysis over several days of replicate samples of control fish, fish fortified with a drug mixture at 1 ppm, 0.1 ppm and 0.01 ppm, and fish dosed with a representative from each drug class. Half of the 38 drugs were confirmed at 0.01 ppm, the lowest fortification level. This included all of the quinolones and fluoroquinolones, the macrolides, malachite green, and most of the imidazoles. Florfenicol amine, metronidazole, sulfonamides, tetracyclines, and most of the betalactams were confirmed at 0.1 ppm. Ivermectin and penicillin G were only detectable in the 1 ppm fortified samples. With the exception of amoxicillin, emamectin, metronidazole, and tylosin, residue presence was confirmed in all the dosed fish.

  3. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xi [Brookhaven National Laboratory, Upton, Long Island, NY 11973 (United States); Huang, Xiaobiao, E-mail: xiahuang@slac.stanford.edu [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2016-08-21

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

  4. A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xi [Brookhaven National Lab. (BNL), Upton, NY (United States); Huang, Xiaobiao [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-08-01

    We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. Furthermore, the fitting results are used for lattice correction. Our method has been successfully demonstrated on the NSLS-II storage ring.

  5. Fully distributed monitoring architecture supporting multiple trackees and trackers in indoor mobile asset management application.

    Science.gov (United States)

    Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju

    2014-03-21

    A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.

  6. Simultaneous detection of multiple HPV DNA via bottom-well microfluidic chip within an infra-red PCR platform.

    Science.gov (United States)

    Liu, Wenjia; Warden, Antony; Sun, Jiahui; Shen, Guangxia; Ding, Xianting

    2018-03-01

    Portable Polymerase Chain Reaction (PCR) devices combined with microfluidic chips or lateral flow stripes have shown great potential in the field of point-of-need testing (PoNT) as they only require a small volume of patient sample and are capable of presenting results in a short time. However, the detection for multiple targets in this field leaves much to be desired. Herein, we introduce a novel PCR platform by integrating a bottom-well microfluidic chip with an infra-red (IR) excited temperature control method and fluorescence co-detection of three PCR products. Microfluidic chips are utilized to partition different samples into individual bottom-wells. The oil phase in the main channel contains multi-walled carbon nanotubes which were used as a heat transfer medium that absorbs energy from the IR-light-emitting diode (LED) and transfers heat to the water phase below. Cyclical rapid heating and cooling necessary for PCR are achieved by alternative power switching of the IR-LED and Universal Serial Bus (USB) mini-fan with a pulse width modulation scheme. This design of the IR-LED PCR platform is economic, compact, and fully portable, making it a promising application in the field of PoNT. The bottom-well microfluidic chip and IR-LED PCR platform were combined to fulfill a three-stage thermal cycling PCR for 40 cycles within 90 min for Human Papilloma Virus (HPV) detection. The PCR fluorescent signal was successfully captured at the end of each cycle. The technique introduced here has broad applications in nucleic acid amplification and PoNT devices.

  7. Validity and Reliability of the Turkish Version of the Monitoring My Multiple Sclerosis Scale.

    Science.gov (United States)

    Polat, Cansu; Tülek, Zeliha; Kürtüncü, Murat; Eraksoy, Mefkure

    2017-06-01

    This research was conducted to adapt the Monitoring My Multiple Sclerosis (MMMS) scale, which is a scale used for self-evaluation by multiple sclerosis (MS) patients of their own health and quality of life, to Turkish and to determine the psychometric properties of the scale. The methodological research was conducted in the outpatient MS clinic of a university hospital between January and September 2013. The sample in this study consisted of 140 patients aged above 18 who had a diagnosis of definite MS. Patients who experienced attacks in the previous month or had any serious medical problems other than MS were not included in the group. The linguistic validity of MMMS was tested by a backward-forward translation method and an expert panel. Reliability analysis was performed using test-retest correlations, item-total correlations, and internal consistency analysis. Confirmatory factor analysis and concurrent validity were used to determine the construct validity. The Multiple Sclerosis Quality of Life-54 instrument was used to determine concurrent validity and the Expanded Disability Status Scale, Hospital Anxiety and Depression Scale, and Mini Mental State Examination were used for further determination of the construct validity. We determined that the scale consisted of four factors with loadings ranging from 0.49 to 0.79. The correlation coefficients of the scale were determined to be between 0.47 and 0.76 for item-total score and between 0.60 and 0.81 for items and subscale scores. Cronbach's alpha coefficient was determined to be 0.94 for the entire scale and between 0.64 and 0.89 for the subscales. Test-retest correlations were significant. Correlations between MMMS and other scales were also found to be significant. The Turkish MMMS provides adequate validity and reliability for assessing the impact of MS on quality of life and health status in patients.

  8. Effect of sequence of insemination after simultaneous thawing of multiple semen straws on conception rate to timed AI in suckled multiparous Nelore cows.

    Science.gov (United States)

    Oliveira, L Z; Arruda, R P; de Andrade, A F C; Santos, R M; Beletti, M E; Peres, R F G; Martins, J P N; de Lima, V F M Hossepian

    2012-11-01

    The objective was to determine the effect of sequence of insemination after simultaneous thawing of multiple 0.5 mL semen straws on conception rate in suckled multiparous Nelore cows. The effect of this thawing procedure on in vitro sperm characteristics was also evaluated. All cows (N = 944) received the same timed AI protocol. Ten straws (0.5 mL) of frozen semen from the same batch were simultaneously thawed at 36 °C, for a minimum of 30 sec. One straw per cow was used for timed AI. Frozen semen from three Angus bulls was used. Timed AI records included sequence of insemination (first to tenth) and time of semen removal from thawing bath. For laboratory analyses, the same semen batches used in the field experiment were evaluated. Ten frozen straws from the same batch were thawed simultaneously in a thawing unit identical to that used in the field experiment. The following sperm characteristics were analyzed: sperm motility parameters, sperm thermal resistance, plasma and acrosomal membrane integrity, lipid peroxidation, chromatin structure, and sperm morphometry. Based on logistic regression, there were no significant effects of breeding group, body condition score, AI technician, and sire on conception rate, but there was an interaction between sire and straw group (P = 0.002). Semen from only one bull had decreased (P conception rates at timed AI, depending on the sire used. Nevertheless, the effects of this thawing environment on in vitro sperm characteristics, remain to be further investigated. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Simultaneous inference of phenotype-associated genes and relevant tissues from GWAS data via Bayesian integration of multiple tissue-specific gene networks.

    Science.gov (United States)

    Wu, Mengmeng; Lin, Zhixiang; Ma, Shining; Chen, Ting; Jiang, Rui; Wong, Wing Hung

    2017-12-01

    Although genome-wide association studies (GWAS) have successfully identified thousands of genomic loci associated with hundreds of complex traits in the past decade, the debate about such problems as missing heritability and weak interpretability has been appealing for effective computational methods to facilitate the advanced analysis of the vast volume of existing and anticipated genetic data. Towards this goal, gene-level integrative GWAS analysis with the assumption that genes associated with a phenotype tend to be enriched in biological gene sets or gene networks has recently attracted much attention, due to such advantages as straightforward interpretation, less multiple testing burdens, and robustness across studies. However, existing methods in this category usually exploit non-tissue-specific gene networks and thus lack the ability to utilize informative tissue-specific characteristics. To overcome this limitation, we proposed a Bayesian approach called SIGNET (Simultaneously Inference of GeNEs and Tissues) to integrate GWAS data and multiple tissue-specific gene networks for the simultaneous inference of phenotype-associated genes and relevant tissues. Through extensive simulation studies, we showed the effectiveness of our method in finding both associated genes and relevant tissues for a phenotype. In applications to real GWAS data of 14 complex phenotypes, we demonstrated the power of our method in both deciphering genetic basis and discovering biological insights of a phenotype. With this understanding, we expect to see SIGNET as a valuable tool for integrative GWAS analysis, thereby boosting the prevention, diagnosis, and treatment of human inherited diseases and eventually facilitating precision medicine.

  11. Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings.

    Science.gov (United States)

    Eide, Per Kristian; Holm, Sverre; Sorteberg, Wilhelm

    2012-09-07

    We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure

  12. Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings

    Directory of Open Access Journals (Sweden)

    Eide Per

    2012-09-01

    Full Text Available Abstract Background We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP; whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. Materials and Methods: During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT. Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. Results Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%, despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. Conclusions Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity

  13. Usefulness of simultaneous and sequential monitoring of glucose level and electrocardiogram in monkeys treated with gatifloxacin under conscious and nonrestricted conditions.

    Science.gov (United States)

    Yoshimatsu, Yu; Ishizaka, Tomomichi; Chiba, Katsuyoshi; Mori, Kazuhiko

    2018-05-10

    Drug-induced cardiac electrophysiological abnormalities accompanied by hypoglycemia or hyperglycemia increase the risk for life-threatening arrhythmia. To assess the drug-induced cardiotoxic potential associated with extraordinary blood glucose (GLU) levels, the effect of gatifloxacin (GFLX) which was frequently associated with GLU abnormality and QT/QTc prolongations in the clinic on blood GLU and electrocardiogram (ECG) parameters was investigated in cynomolgus monkeys (n=4) given GFLX orally in an ascending dose regimen (10, 30, 60 and 100 mg/kg). Simultaneous and sequential GLU and ECG monitoring with a continuous GLU monitoring system and Holter ECG, respectively, were conducted for 24 h under free-moving conditions. Consequently, GFLX at 30 and 60 mg/kg dose-dependently induced a transient decrease in GLU without any ECG abnormality 2-4 h postdose. Highest dose of 100 mg/kg caused severe hypoglycemia with a mean GLU of sequential GLU monitoring data clearly distinguished between GFLX-induced GLU abnormality and physiological GLU changes influenced by feeding throughout the day. In conclusion, the combined assessment of continuous GLU and ECG monitoring is valuable in predicting the drug-induced cardio-electrophysiological risk associated with both GLU and ECG abnormalities.

  14. Additive effects prevail: The response of biota to multiple stressors in an intensively monitored watershed.

    Science.gov (United States)

    Gieswein, Alexander; Hering, Daniel; Feld, Christian K

    2017-09-01

    Freshwater ecosystems are impacted by a range of stressors arising from diverse human-caused land and water uses. Identifying the relative importance of single stressors and understanding how multiple stressors interact and jointly affect biology is crucial for River Basin Management. This study addressed multiple human-induced stressors and their effects on the aquatic flora and fauna based on data from standard WFD monitoring schemes. For altogether 1095 sites within a mountainous catchment, we used 12 stressor variables covering three different stressor groups: riparian land use, physical habitat quality and nutrient enrichment. Twenty-one biological metrics calculated from taxa lists of three organism groups (fish, benthic invertebrates and aquatic macrophytes) served as response variables. Stressor and response variables were subjected to Boosted Regression Tree (BRT) analysis to identify stressor hierarchy and stressor interactions and subsequently to Generalised Linear Regression Modelling (GLM) to quantify the stressors standardised effect size. Our results show that riverine habitat degradation was the dominant stressor group for the river fauna, notably the bed physical habitat structure. Overall, the explained variation in benthic invertebrate metrics was higher than it was in fish and macrophyte metrics. In particular, general integrative (aggregate) metrics such as % Ephemeroptera, Plecoptera and Trichoptera (EPT) taxa performed better than ecological traits (e.g. % feeding types). Overall, additive stressor effects dominated, while significant and meaningful stressor interactions were generally rare and weak. We concluded that given the type of stressor and ecological response variables addressed in this study, river basin managers do not need to bother much about complex stressor interactions, but can focus on the prevailing stressors according to the hierarchy identified. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Multiple reaction monitoring (MRM)-profiling for biomarker discovery applied to human polycystic ovarian syndrome.

    Science.gov (United States)

    Cordeiro, Fernanda B; Ferreira, Christina R; Sobreira, Tiago Jose P; Yannell, Karen E; Jarmusch, Alan K; Cedenho, Agnaldo P; Lo Turco, Edson G; Cooks, R Graham

    2017-09-15

    We describe multiple reaction monitoring (MRM)-profiling, which provides accelerated discovery of discriminating molecular features, and its application to human polycystic ovary syndrome (PCOS) diagnosis. The discovery phase of the MRM-profiling seeks molecular features based on some prior knowledge of the chemical functional groups likely to be present in the sample. It does this through use of a limited number of pre-chosen and chemically specific neutral loss and/or precursor ion MS/MS scans. The output of the discovery phase is a set of precursor/product transitions. In the screening phase these MRM transitions are used to interrogate multiple samples (hence the name MRM-profiling). MRM-profiling was applied to follicular fluid samples of 22 controls and 29 clinically diagnosed PCOS patients. Representative samples were delivered by flow injection to a triple quadrupole mass spectrometer set to perform a number of pre-chosen and chemically specific neutral loss and/or precursor ion MS/MS scans. The output of this discovery phase was a set of 1012 precursor/product transitions. In the screening phase each individual sample was interrogated for these MRM transitions. Principal component analysis (PCA) and receiver operating characteristic (ROC) curves were used for statistical analysis. To evaluate the method's performance, half the samples were used to build a classification model (testing set) and half were blinded (validation set). Twenty transitions were used for the classification of the blind samples, most of them (N = 19) showed lower abundances in the PCOS group and corresponded to phosphatidylethanolamine (PE) and phosphatidylserine (PS) lipids. Agreement of 73% with clinical diagnosis was found when classifying the 26 blind samples. MRM-profiling is a supervised method characterized by its simplicity, speed and the absence of chromatographic separation. It can be used to rapidly isolate discriminating molecules in healthy/disease conditions by

  16. Verification of multimarkers for detection of early stage diabetic retinopathy using multiple reaction monitoring.

    Science.gov (United States)

    Kim, Kyunggon; Kim, Sang Jin; Han, Dohyun; Jin, Jonghwa; Yu, Jiyoung; Park, Kyong Soo; Yu, Hyeong Gon; Kim, Youngsoo

    2013-03-01

    Diabetic retinopathy (DR) is a complication of diabetes and 80% of diabetes mellitus (DM) patients whose DM duration is over 10 years can be expected to suffer with DR. The diagnosis of DR depends on an ophthalmological examination, and no molecular methods of screening DR status exist. Nonproliferative diabetic retinopathy (NPDR) is the early DR which is hard to be noticed in early NPDR, showing significant cause of adult blindness in type 2 diabetes patients. Protein biomarkers have been valuable in the diagnosis of disease and the use of multiple biomarkers has been suggested to overcome the low specificity of single ones. For biomarker development, multiple reaction monitoring (MRM) has been spotlighted as an alternative method to quantify target proteins with no need for immunoassay. In this study, 54 candidate DR marker proteins from a previous study were verified by MRM in plasma samples from NPDR patients in 3 stages (mild, moderate and severe; 15 cases each) and diabetic patients without retinopathy (15 cases) as a control. Notably, 27 candidate markers distinguished moderate NPDR from type 2 diabetic patients with no diabetic retinopathy, generating AUC values (>0.7). Specifically, 28 candidate proteins underwent changes in expression as type 2 diabetic patients with no diabetic retinopathy progressed to mild and moderate NPDR. Further, a combination of 4 markers from these 28 candidates had the improved specificity in distinguishing moderate NPDR from type 2 diabetic patients with no diabetic retinopathy, yielding a merged AUC value of nearly 1.0. We concluded that MRM is a fast, robust approach of multimarker panel determination and an assay platform that provides improved specificity compared with single biomarker assay systems.

  17. Development of a method for rapid and simultaneous monitoring of particulate and dissolved radiocesium in water with nonwoven fabric cartridge filters

    International Nuclear Information System (INIS)

    Hideki Tsuji; Tetsuo Yasutaka; Yoshihiko Kondo; Yasukazu Suzuki

    2014-01-01

    A method for the rapid and simultaneous monitoring of particulate and dissolved 137 Cs concentration in water was developed. This method uses pleated polypropylene nonwoven fabric filter to collect particulate radiocesium, and nonwoven fabric impregnated with Prussian blue (PB) to absorb dissolved radiocesium. The fabric was placed into cylindrical plastic cartridges (SS-cartridge and PB-cartridge). Traditional monitoring methods, such as evaporative concentration, often require time for pre-processing. However, this method described requires much less pre-processing time before the detection. Experiments conducted with simulated river water demonstrated that almost all of the suspended solids weight was collected in the SS-cartridge, and that more than 92 % of dissolved 137 Cs was absorbed onto the two PB-cartridges by 2.5 L/min flow rate when the range of the pH was 6-8. This device was applied to monitor Abukuma River water at two locations and the results were compared with those obtained using the filtrating and evaporative concentration method. The suspended solids concentration in river water, calculated by weight gain of the SS-cartridge and by sediment weight after filtration with a 0.45-μm membrane filter, agreed well. The radioactivity of the particulate and dissolved 137 Cs also agreed well in one of the two replications of this method. In addition, the required time for pre-processing was reduced by 60 times that by filtrating and evaporative concentration method. This method can separately collect and concentrate particulate and dissolved radiocesium rapidly and simultaneously in the field. (author)

  18. The continuous monitoring of the artificial beta aerosol activity by measuring the alpha and beta activity in aerosol simultaneously

    International Nuclear Information System (INIS)

    Hayakawa, Hironobu; Oonishi, Masaki; Matsuura, Hiroyuki

    1990-01-01

    We have constructed the system to monitor the artificial beta aerosol activity around the nuclear power plants continuously in real time. The smaller releases of artificial radionuclides from the nuclear power plants can be lost in the fluctuations of the natural background of the beta aerosol activity, when only the beta activity of the aerosol is measured. This method to discriminate the artificial and the natural beta activity of the aerosol is based on the fact that the ratio of the natural alpha and beta activities of the aerosol is almost constant. The detection limit of this system is below 3 Bq/m 3 . (author)

  19. Generation and monitoring of discrete stable random processes using multiple immigration population models

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, J O; Hopcraft, K I; Jakeman, E [Applied Mathematics Division, School of Mathematical Sciences, University of Nottingham, Nottingham, NG7 2RD (United Kingdom)

    2003-11-21

    Some properties of classical population processes that comprise births, deaths and multiple immigrations are investigated. The rates at which the immigrants arrive can be tailored to produce a population whose steady state fluctuations are described by a pre-selected distribution. Attention is focused on the class of distributions with a discrete stable law, which have power-law tails and whose moments and autocorrelation function do not exist. The separate problem of monitoring and characterizing the fluctuations is studied, analysing the statistics of individuals that leave the population. The fluctuations in the size of the population are transferred to the times between emigrants that form an intermittent time series of events. The emigrants are counted with a detector of finite dynamic range and response time. This is modelled through clipping the time series or saturating it at an arbitrary but finite level, whereupon its moments and correlation properties become finite. Distributions for the time to the first counted event and for the time between events exhibit power-law regimes that are characteristic of the fluctuations in population size. The processes provide analytical models with which properties of complex discrete random phenomena can be explored, and in addition provide generic means by which random time series encompassing a wide range of intermittent and other discrete random behaviour may be generated.

  20. Generation and monitoring of discrete stable random processes using multiple immigration population models

    International Nuclear Information System (INIS)

    Matthews, J O; Hopcraft, K I; Jakeman, E

    2003-01-01

    Some properties of classical population processes that comprise births, deaths and multiple immigrations are investigated. The rates at which the immigrants arrive can be tailored to produce a population whose steady state fluctuations are described by a pre-selected distribution. Attention is focused on the class of distributions with a discrete stable law, which have power-law tails and whose moments and autocorrelation function do not exist. The separate problem of monitoring and characterizing the fluctuations is studied, analysing the statistics of individuals that leave the population. The fluctuations in the size of the population are transferred to the times between emigrants that form an intermittent time series of events. The emigrants are counted with a detector of finite dynamic range and response time. This is modelled through clipping the time series or saturating it at an arbitrary but finite level, whereupon its moments and correlation properties become finite. Distributions for the time to the first counted event and for the time between events exhibit power-law regimes that are characteristic of the fluctuations in population size. The processes provide analytical models with which properties of complex discrete random phenomena can be explored, and in addition provide generic means by which random time series encompassing a wide range of intermittent and other discrete random behaviour may be generated

  1. Functional near infrared spectroscopy of the sensory and motor brain regions with simultaneous kinematic and EMG monitoring during motor tasks.

    Science.gov (United States)

    Sukal-Moulton, Theresa; de Campos, Ana Carolina; Stanley, Christopher J; Damiano, Diane L

    2014-12-05

    There are several advantages that functional near-infrared spectroscopy (fNIRS) presents in the study of the neural control of human movement. It is relatively flexible with respect to participant positioning and allows for some head movements during tasks. Additionally, it is inexpensive, light weight, and portable, with very few contraindications to its use. This presents a unique opportunity to study functional brain activity during motor tasks in individuals who are typically developing, as well as those with movement disorders, such as cerebral palsy. An additional consideration when studying movement disorders, however, is the quality of actual movements performed and the potential for additional, unintended movements. Therefore, concurrent monitoring of both blood flow changes in the brain and actual movements of the body during testing is required for appropriate interpretation of fNIRS results. Here, we show a protocol for the combination of fNIRS with muscle and kinematic monitoring during motor tasks. We explore gait, a unilateral multi-joint movement (cycling), and two unilateral single-joint movements (isolated ankle dorsiflexion, and isolated hand squeezing). The techniques presented can be useful in studying both typical and atypical motor control, and can be modified to investigate a broad range of tasks and scientific questions.

  2. [Construction and analysis of a monitoring system with remote real-time multiple physiological parameters based on cloud computing].

    Science.gov (United States)

    Zhu, Lingyun; Li, Lianjie; Meng, Chunyan

    2014-12-01

    There have been problems in the existing multiple physiological parameter real-time monitoring system, such as insufficient server capacity for physiological data storage and analysis so that data consistency can not be guaranteed, poor performance in real-time, and other issues caused by the growing scale of data. We therefore pro posed a new solution which was with multiple physiological parameters and could calculate clustered background data storage and processing based on cloud computing. Through our studies, a batch processing for longitudinal analysis of patients' historical data was introduced. The process included the resource virtualization of IaaS layer for cloud platform, the construction of real-time computing platform of PaaS layer, the reception and analysis of data stream of SaaS layer, and the bottleneck problem of multi-parameter data transmission, etc. The results were to achieve in real-time physiological information transmission, storage and analysis of a large amount of data. The simulation test results showed that the remote multiple physiological parameter monitoring system based on cloud platform had obvious advantages in processing time and load balancing over the traditional server model. This architecture solved the problems including long turnaround time, poor performance of real-time analysis, lack of extensibility and other issues, which exist in the traditional remote medical services. Technical support was provided in order to facilitate a "wearable wireless sensor plus mobile wireless transmission plus cloud computing service" mode moving towards home health monitoring for multiple physiological parameter wireless monitoring.

  3. Camera-based microswitch technology to monitor mouth, eyebrow, and eyelid responses of children with profound multiple disabilities

    NARCIS (Netherlands)

    Lancioni, G.E.; Bellini, D.; Oliva, D.; Singh, N.N.; O'Reilly, M.F.; Sigafoos, J.; Lang, R.B.; Didden, H.C.M.

    2011-01-01

    A camera-based microswitch technology was recently used to successfully monitor small eyelid and mouth responses of two adults with profound multiple disabilities (Lancioni et al., Res Dev Disab 31:1509-1514, 2010a). This technology, in contrast with the traditional optic microswitches used for

  4. High-performance metabolic profiling of plasma from seven mammalian species for simultaneous environmental chemical surveillance and bioeffect monitoring.

    Science.gov (United States)

    Park, Youngja H; Lee, Kichun; Soltow, Quinlyn A; Strobel, Frederick H; Brigham, Kenneth L; Parker, Richard E; Wilson, Mark E; Sutliff, Roy L; Mansfield, Keith G; Wachtman, Lynn M; Ziegler, Thomas R; Jones, Dean P

    2012-05-16

    High-performance metabolic profiling (HPMP) by Fourier-transform mass spectrometry coupled to liquid chromatography gives relative quantification of thousands of chemicals in biologic samples but has had little development for use in toxicology research. In principle, the approach could be useful to detect complex metabolic response patterns to toxicologic exposures and to detect unusual abundances or patterns of potentially toxic chemicals. As an initial study to develop these possible uses, we applied HPMP and bioinformatics analysis to plasma of humans, rhesus macaques, marmosets, pigs, sheep, rats and mice to determine: (1) whether more chemicals are detected in humans living in a less controlled environment than captive species and (2) whether a subset of plasma chemicals with similar inter-species and intra-species variation could be identified for use in comparative toxicology. Results show that the number of chemicals detected was similar in humans (3221) and other species (range 2537-3373). Metabolite patterns were most similar within species and separated samples according to family and order. A total of 1485 chemicals were common to all species; 37% of these matched chemicals in human metabolomic databases and included chemicals in 137 out of 146 human metabolic pathways. Probability-based modularity clustering separated 644 chemicals, including many endogenous metabolites, with inter-species variation similar to intra-species variation. The remaining chemicals had greater inter-species variation and included environmental chemicals as well as GSH and methionine. Together, the data suggest that HPMP provides a platform that can be useful within human populations and controlled animal studies to simultaneously evaluate environmental exposures and biological responses to such exposures. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  6. Development of an asymmetric multiple-position neutron source (AMPNS) method to monitor the criticality of a degraded reactor core

    International Nuclear Information System (INIS)

    Kim, S.S.; Levine, S.H.

    1985-01-01

    An analytical/experimental method has been developed to monitor the subcritical reactivity and unfold the k/sub infinity/ distribution of a degraded reactor core. The method uses several fixed neutron detectors and a Cf-252 neutron source placed sequentially in multiple positions in the core. Therefore, it is called the Asymmetric Multiple Position Neutron Source (AMPNS) method. The AMPNS method employs nucleonic codes to analyze the neutron multiplication of a Cf-252 neutron source. An optimization program, GPM, is utilized to unfold the k/sub infinity/ distribution of the degraded core, in which the desired performance measure minimizes the error between the calculated and the measured count rates of the degraded reactor core. The analytical/experimental approach is validated by performing experiments using the Penn State Breazeale TRIGA Reactor (PSBR). A significant result of this study is that it provides a method to monitor the criticality of a damaged core during the recovery period

  7. Evaluation of a multiple-species approach to monitoring species at the ecoregional scale

    Science.gov (United States)

    Patricia N. Manley; William J. Zielinski; Matthew D. Schlesinger; Sylvia R. Mori

    2004-01-01

    Monitoring is required of land managers and conservation practitioners to assess the success of management actions. "Shortcuts" are sought to reduce monitoring costs, most often consisting of the selection of a small number of species that are closely monitored to represent the status of many associated species and environmental correlates. Assumptions...

  8. PKS 2005-489 at VHE: four years of monitoring with HESS and simultaneous multi-wavelength observations

    Science.gov (United States)

    H.E.S.S. Collaboration; Acero, F.; Aharonian, F.; Akhperjanian, A. G.; Anton, G.; Barres de Almeida, U.; Bazer-Bachi, A. R.; Becherini, Y.; Behera, B.; Benbow, W.; Bernlöhr, K.; Bochow, A.; Boisson, C.; Bolmont, J.; Borrel, V.; Brucker, J.; Brun, F.; Brun, P.; Bühler, R.; Bulik, T.; Büsching, I.; Boutelier, T.; Chadwick, P. M.; Charbonnier, A.; Chaves, R. C. G.; Cheesebrough, A.; Chounet, L.-M.; Clapson, A. C.; Coignet, G.; Costamante, L.; Dalton, M.; Daniel, M. K.; Davids, I. D.; Degrange, B.; Deil, C.; Dickinson, H. J.; Djannati-Ataï, A.; Domainko, W.; O'C. Drury, L.; Dubois, F.; Dubus, G.; Dyks, J.; Dyrda, M.; Egberts, K.; Eger, P.; Espigat, P.; Fallon, L.; Farnier, C.; Fegan, S.; Feinstein, F.; Fiasson, A.; Förster, A.; Fontaine, G.; Füßling, M.; Gabici, S.; Gallant, Y. A.; Gérard, L.; Gerbig, D.; Giebels, B.; Glicenstein, J. F.; Glück, B.; Goret, P.; Göring, D.; Hauser, M.; Heinz, S.; Heinzelmann, G.; Henri, G.; Hermann, G.; Hinton, J. A.; Hoffmann, A.; Hofmann, W.; Hofverberg, P.; Holleran, M.; Hoppe, S.; Horns, D.; Jacholkowska, A.; de Jager, O. C.; Jahn, C.; Jung, I.; Katarzyński, K.; Katz, U.; Kaufmann, S.; Kerschhaggl, M.; Khangulyan, D.; Khélifi, B.; Keogh, D.; Klochkov, D.; Kluźniak, W.; Kneiske, T.; Komin, Nu.; Kosack, K.; Kossakowski, R.; Lamanna, G.; Lenain, J.-P.; Lohse, T.; Marandon, V.; Martineau-Huynh, O.; Marcowith, A.; Masbou, J.; Maurin, D.; McComb, T. J. L.; Medina, M. C.; Méhault, J.; Moderski, R.; Moulin, E.; Naumann-Godo, M.; de Naurois, M.; Nedbal, D.; Nekrassov, D.; Nicholas, B.; Niemiec, J.; Nolan, S. J.; Ohm, S.; Olive, J.-F.; de Oña Wilhelmi, E.; Orford, K. J.; Ostrowski, M.; Panter, M.; Paz Arribas, M.; Pedaletti, G.; Pelletier, G.; Petrucci, P.-O.; Pita, S.; Pühlhofer, G.; Punch, M.; Quirrenbach, A.; Raubenheimer, B. C.; Raue, M.; Rayner, S. M.; Renaud, M.; Rieger, F.; Ripken, J.; Rob, L.; Rosier-Lees, S.; Rowell, G.; Rudak, B.; Rulten, C. B.; Ruppel, J.; Sahakian, V.; Santangelo, A.; Schlickeiser, R.; Schöck, F. M.; Schwanke, U.; Schwarzburg, S.; Schwemmer, S.; Shalchi, A.; Sikora, M.; Skilton, J. L.; Sol, H.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Stinzing, F.; Superina, G.; Szostek, A.; Tam, P. H.; Tavernet, J.-P.; Terrier, R.; Tibolla, O.; Tluczykont, M.; van Eldik, C.; Vasileiadis, G.; Venter, C.; Venter, L.; Vialle, J. P.; Vincent, P.; Vivier, M.; Völk, H. J.; Volpe, F.; Wagner, S. J.; Ward, M.; Zdziarski, A. A.; Zech, A.

    2010-02-01

    Aims: Our aim is to study the very high energy (VHE; E>100 GeV) γ-ray emission from BL Lac objects and the evolution in time of their broad-band spectral energy distribution (SED). Methods: VHE observations of the high-frequency peaked BL Lac object PKS 2005-489 were made with the High Energy Stereoscopic System (HESS) from 2004 through 2007. Three simultaneous multi-wavelength campaigns at lower energies were performed during the HESS data taking, consisting of several individual pointings with the XMM-Newton and RXTE satellites. Results: A strong VHE signal, ~17σ total, from PKS 2005-489 was detected during the four years of HESS observations (90.3 h live time). The integral flux above the average analysis threshold of 400 GeV is ~3% of the flux observed from the Crab Nebula and varies weakly on time scales from days to years. The average VHE spectrum measured from ~300 GeV to ~5 TeV is characterized by a power law with a photon index, Γ = 3.20± 0.16_stat± 0.10_syst. At X-ray energies the flux is observed to vary by more than an order of magnitude between 2004 and 2005. Strong changes in the X-ray spectrum (ΔΓX ≈ 0.7) are also observed, which appear to be mirrored in the VHE band. Conclusions: The SED of PKS 2005-489, constructed for the first time with contemporaneous data on both humps, shows significant evolution. The large flux variations in the X-ray band, coupled with weak or no variations in the VHE band and a similar spectral behavior, suggest the emergence of a new, separate, harder emission component in September 2005. Supported by CAPES Foundation, Ministry of Education of Brazil.Now at Harvard-Smithsonian Center for Astrophysics, Cambridge, USA.Now at W.W. Hansen Experimental Physics Laboratory & Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, Stanford, USA.

  9. Statistical framework for the utilization of simultaneous pupil plane and focal plane telemetry for exoplanet imaging. I. Accounting for aberrations in multiple planes.

    Science.gov (United States)

    Frazin, Richard A

    2016-04-01

    A new generation of telescopes with mirror diameters of 20 m or more, called extremely large telescopes (ELTs), has the potential to provide unprecedented imaging and spectroscopy of exoplanetary systems, if the difficulties in achieving the extremely high dynamic range required to differentiate the planetary signal from the star can be overcome to a sufficient degree. Fully utilizing the potential of ELTs for exoplanet imaging will likely require simultaneous and self-consistent determination of both the planetary image and the unknown aberrations in multiple planes of the optical system, using statistical inference based on the wavefront sensor and science camera data streams. This approach promises to overcome the most important systematic errors inherent in the various schemes based on differential imaging, such as angular differential imaging and spectral differential imaging. This paper is the first in a series on this subject, in which a formalism is established for the exoplanet imaging problem, setting the stage for the statistical inference methods to follow in the future. Every effort has been made to be rigorous and complete, so that validity of approximations to be made later can be assessed. Here, the polarimetric image is expressed in terms of aberrations in the various planes of a polarizing telescope with an adaptive optics system. Further, it is shown that current methods that utilize focal plane sensing to correct the speckle field, e.g., electric field conjugation, rely on the tacit assumption that aberrations on multiple optical surfaces can be represented as aberration on a single optical surface, ultimately limiting their potential effectiveness for ground-based astronomy.

  10. The relationship between ST segment deviation projected to the front of the chest during exercise and simultaneous Holter monitoring

    DEFF Research Database (Denmark)

    Egstrup, K

    1988-01-01

    were placed to correspond to CM5 and an aVF-like lead. In 36 patients, ST segment changes were found with both Holter and the 12-lead precordial electrocardiogram, while in 12 patients no ischaemic changes were detected by either method. Thus the results of the two methods concurred in 48 of 50 patient...... (96%). The magnitude of the ischaemic change was similar in 24 of 36 patients (67%), while the Holter system underestimated the ischaemic change by 0.5-2.0 mm in 12 patients. When the maximal ST segment deviation in V5 was compared with CM5, the deviations with both systems were identical in all...... but one patient in whom a difference of 0.5 mm was found. The use of a Holter lead resembling a VF identified maximal ST segment change on only one occasion, and in only four patients was an ST segment change of 1 mm noted. In conclusion, ambulatory monitoring utilizing only CM5 seems to detect most...

  11. Simultaneous Determination of Antipsychotic Drugs and Their Active Metabolites by LC-MS-MS and its Application to Therapeutic Drug Monitoring.

    Science.gov (United States)

    Miroshnichenko, Igor I; Baymeeva, Natalia V

    2018-04-07

    A quantitative method was developed to support therapeutic drug monitoring of eight antipsychotic drugs: chlorpromazine, haloperidol, zuclopenthixol, clozapine, risperidone, quetiapine, aripiprazole or olanzapine and some active metabolites (dehydroaripiprazole, N-desmethylclozapine and 9-hydroxyrisperidone) in human serum. Separation of the compounds was achieved using a Zorbax SB-C18 (150 mm × 4.6 mm, 5 μm) column and mass-spectrometric detection in multiple reaction monitoring mode. Human blood samples were collected in vacutainer tubes and the analytes were extracted with methyl-tert-butyl ether. The lower limits of quantitation were equal 0.5-1 ng/mL for all analytes. The method was applied with success to serum samples from schizophrenic patients undergoing polypharmacy with two or more different antipsychotic drugs. Precision data, accuracy results were satisfactory, and no interference from other psychotropic drugs was found. Hence, the method is suitable for the TDM of the analytes in psychotic patients' serum.

  12. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  13. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    International Nuclear Information System (INIS)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric; Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt; Audouin, Laurent; Tassan-Got, Laurent; Aumann, Thomas; Casarejos, Enrique; Farget, Fanny; Rodriguez-Tajes, Carme; Heinz, Andreas; Jurado, Beatriz; Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut

    2015-01-01

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  14. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric [CEA DAM Bruyeres-le-Chatel, Arpajon (France); Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Audouin, Laurent; Tassan-Got, Laurent [CNRS/IN2P3, IPNO, Orsay (France); Aumann, Thomas [Technische Universitaet Darmstadt, Darmstadt (Germany); Casarejos, Enrique [Universidad de Vigo, Vigo (Spain); Farget, Fanny; Rodriguez-Tajes, Carme [CNRS/IN2P3, GANIL, Caen (France); Heinz, Andreas [Chalmers University of Technology, Gothenburg (Sweden); Jurado, Beatriz [CNRS/IN2P3, CENBG, Gradignan (France); Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2015-12-15

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  15. LC-MS/MS method for simultaneous determination of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin in serum of multiple myeloma patients.

    Science.gov (United States)

    Shu, Chang; Zeng, Tianmei; Gao, Shouhong; Xia, Tianyi; Huang, Lifeng; Zhang, Feng; Chen, Wansheng

    2016-08-15

    Multiple myeloma (MM), a malignant neoplastic serum-cell disorder, has been a serious threat to human health. The determination of 6 commonly used drug concentrations, including thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin, in MM patients was of great clinical interest. Herein, we reported a method for the rapid and simultaneous measurement of the above therapeutics by liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method with solid phase extraction. Analysis was performed on a Waters XBridge(®) BEH C18 column (2.5μm, 2.1 mm×50mm), with formic acid aqueous solution and acetonitrile as the mobile phase at flow rate 0.3mL/min. All analytes showed good correlation coefficients (r>0.996), and LLOQ of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin were 4, 2, 2, 2, 2 and 2ng/mL, respectively. The inter- and intra-day precisions and stability were expressed as variation coefficients within 15% and relative error less than 15%. Dilution effect, carryover and incurred sample reanalysis were investigated according to the 2015 edition Chinese Pharmacopoeia guidelines, as US FDA (2013, revision 1) required. The LC-MS/MS based assay described in this article may improve future clinical studies evaluating common therapeutics for MM treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Radiation exposure control by estimation of multiplication factors for online remote radiation monitoring systems at vitrification plant

    International Nuclear Information System (INIS)

    Deokar, U.V.; Kulkarni, V.V.; Khot, A.R.; Mathew, P.; Kamlesh; Purohit, R.G.; Sarkar, P.K.

    2012-01-01

    Vitrification Plant is commissioned for vitrification of high level liquid waste (HLW) generated in nuclear fuel cycle operations by using Joule Heated Ceramic Melter first time in India. Exposure control is a major concern in operating plant. Therefore in addition to installed monitors, we have developed online remote radiation monitoring system to minimize number of entries in amber areas and to reduce the exposure to the surveyor and operator. This also helped in volume reduction of secondary waste. The reliability and accuracy of the online monitoring system is confirmed with actual measurements and by theoretical shielding calculations. The multiplication factors were estimated for remote on line monitoring of Melter Off Gas (MOG) filter, Hood filter, three exhaust filter banks, and over-pack monitoring. This paper summarizes - how the online remote monitoring system helped in saving of 128.52 person-mSv collective dose (14.28% of budgeted dose). The system also helped in the reduction of 2.6 m 3 of Cat-I waste. Our online remote monitoring system has helped the plant management to plan in advance for replacement of these filters, which resulted in considerable saving in collective dose and secondary waste

  17. Near Real Time Structural Health Monitoring with Multiple Sensors in a Cloud Environment

    Science.gov (United States)

    Bock, Y.; Todd, M.; Kuester, F.; Goldberg, D.; Lo, E.; Maher, R.

    2017-12-01

    A repeated near real time 3-D digital surrogate representation of critical engineered structures can be used to provide actionable data on subtle time-varying displacements in support of disaster resiliency. We describe a damage monitoring system of optimally-integrated complementary sensors, including Global Navigation Satellite Systems (GNSS), Micro-Electro-Mechanical Systems (MEMS) accelerometers coupled with the GNSS (seismogeodesy), light multi-rotor Unmanned Aerial Vehicles (UAVs) equipped with high-resolution digital cameras and GNSS/IMU, and ground-based Light Detection and Ranging (LIDAR). The seismogeodetic system provides point measurements of static and dynamic displacements and seismic velocities of the structure. The GNSS ties the UAV and LIDAR imagery to an absolute reference frame with respect to survey stations in the vicinity of the structure to isolate the building response to ground motions. The GNSS/IMU can also estimate the trajectory of the UAV with respect to the absolute reference frame. With these constraints, multiple UAVs and LIDAR images can provide 4-D displacements of thousands of points on the structure. The UAV systematically circumnavigates the target structure, collecting high-resolution image data, while the ground LIDAR scans the structure from different perspectives to create a detailed baseline 3-D reference model. UAV- and LIDAR-based imaging can subsequently be repeated after extreme events, or after long time intervals, to assess before and after conditions. The unique challenge is that disaster environments are often highly dynamic, resulting in rapidly evolving, spatio-temporal data assets with the need for near real time access to the available data and the tools to translate these data into decisions. The seismogeodetic analysis has already been demonstrated in the NASA AIST Managed Cloud Environment (AMCE) designed to manage large NASA Earth Observation data projects on Amazon Web Services (AWS). The Cloud provides

  18. Gully Erosion Mapping and Monitoring at Multiple Scales Based on Multi-Source Remote Sensing Data of the Sancha River Catchment, Northeast China

    Directory of Open Access Journals (Sweden)

    Ranghu Wang

    2016-11-01

    Full Text Available This research is focused on gully erosion mapping and monitoring at multiple spatial scales using multi-source remote sensing data of the Sancha River catchment in Northeast China, where gullies extend over a vast area. A high resolution satellite image (Pleiades 1A, 0.7 m was used to obtain the spatial distribution of the gullies of the overall basin. Image visual interpretation with field verification was employed to map the geometric gully features and evaluate gully erosion as well as the topographic differentiation characteristics. Unmanned Aerial Vehicle (UAV remote sensing data and the 3D photo-reconstruction method were employed for detailed gully mapping at a site scale. The results showed that: (1 the sub-meter image showed a strong ability in the recognition of various gully types and obtained satisfactory results, and the topographic factors of elevation, slope and slope aspects exerted significant influence on the gully spatial distribution at the catchment scale; and (2 at a more detailed site scale, UAV imagery combined with 3D photo-reconstruction provided a Digital Surface Model (DSM and ortho-image at the centimeter level as well as a detailed 3D model. The resulting products revealed the area of agricultural utilization and its shaping by human agricultural activities and water erosion in detail, and also provided the gully volume. The present study indicates that using multi-source remote sensing data, including satellite and UAV imagery simultaneously, results in an effective assessment of gully erosion over multiple spatial scales. The combined approach should be continued to regularly monitor gully erosion to understand the erosion process and its relationship with the environment from a comprehensive perspective.

  19. ADNP-CSMA Random Multiple Access protocol application with the function of monitoring in Ad Hoc network

    Directory of Open Access Journals (Sweden)

    Zhan Gang

    2016-01-01

    Full Text Available In Ad Hoc networks,the net work of mobile nodes exchange information with their wireless transceiver equipment,the network throughput is in increased,compared to other such multiple hops network.Moreover along with the rapid development of modern information,communication business also will be increase.However,the access and adaptive of previous CSMA protocol are insufficient.According to these properties,this paper presents a kind of adaptive dual clock with monitoring function P-CSMA random multiple access protocol(ADNP-CSMA,and discusses two kinds of P-CSMA.ACK with monitoring function is introduced to maintain the stability of the whole system,and the introduction of dual clock mechanism reduces the channel of idle period.It calculate the system throughput expression through the method of average period,and the simulation results show that the system is constant in the case of high load throughput.

  20. Toward daily monitoring of vegetation conditions at field scale through fusing data from multiple sensors

    Science.gov (United States)

    Vegetation monitoring requires remote sensing data at fine spatial and temporal resolution. While imagery from coarse resolution sensors such as MODIS/VIIRS can provide daily observations, they lack spatial detail to capture surface features for crop and rangeland monitoring. The Landsat satellite s...

  1. Radiation exposure control by estimation of multiplication factors for online remote radiation monitoring systems at Vitrification Plant

    International Nuclear Information System (INIS)

    Deokar, Umesh V.; Kukarni, V.V.; Khot, A.R.; Mathew, P.; Kamlesh; Purohit, R.G.; Sarkar, P.K.

    2011-01-01

    Vitrification Plant is commissioned for vitrification of high-level liquid waste generated in Nuclear Fuel Cycle operations by using Joule Heated Ceramic Melter first time in India. Exposure control is a major concern in operating plant. Therefore, in addition to installed monitors, we have developed online remote radiation monitoring system to minimize number of entries in amber areas and to reduce the exposure to the surveyor and operator. This also helped in volume reduction of secondary waste. The reliability and accuracy of the online monitoring system is confirmed with actual measurements and by theoretical shielding calculations. The multiplication factors were estimated for remote online monitoring of Melter off Gas (MOG) filter, Hood filter, three exhaust filter banks, and overpack monitoring. This paper summarizes how the online remote monitoring system had helped in saving of 128.52 Person-mSv collective dose (14.28% of budgeted dose) and also there was 2.6 m 3 reduction in generation of Cat-I waste. (author)

  2. Cytokinetically quiescent (G0/G1) human multiple myeloma cells are susceptible to simultaneous inhibition of Chk1 and MEK1/2.

    Science.gov (United States)

    Pei, Xin-Yan; Dai, Yun; Youssefian, Leena E; Chen, Shuang; Bodie, Wesley W; Takabatake, Yukie; Felthousen, Jessica; Almenara, Jorge A; Kramer, Lora B; Dent, Paul; Grant, Steven

    2011-11-10

    Effects of Chk1 and MEK1/2 inhibition were investigated in cytokinetically quiescent multiple myeloma (MM) and primary CD138(+) cells. Coexposure to the Chk1 and MEK1/2 inhibitors AZD7762 and selumetinib (AZD6244) robustly induced apoptosis in various MM cells and CD138(+) primary samples, but spared normal CD138(-) and CD34(+) cells. Furthermore, Chk1/MEK1/2 inhibitor treatment of asynchronized cells induced G(0)/G(1) arrest and increased apoptosis in all cell-cycle phases, including G(0)/G(1). To determine whether this regimen is active against quiescent G(0)/G(1) MM cells, cells were cultured in low-serum medium to enrich the G(0)/G(1) population. G(0)/G(1)-enriched cells exhibited diminished sensitivity to conventional agents (eg, Taxol and VP-16) but significantly increased susceptibility to Chk1 ± MEK1/2 inhibitors or Chk1 shRNA knock-down. These events were associated with increased γH2A.X expression/foci formation and Bim up-regulation, whereas Bim shRNA knock-down markedly attenuated lethality. Immunofluorescent analysis of G(0)/G(1)-enriched or primary MM cells demonstrated colocalization of activated caspase-3 and the quiescent (G(0)) marker statin, a nuclear envelope protein. Finally, Chk1/MEK1/2 inhibition increased cell death in the Hoechst-positive (Hst(+)), low pyronin Y (PY)-staining (2N Hst(+)/PY(-)) G(0) population and in sorted small side-population (SSP) MM cells. These findings provide evidence that cytokinetically quiescent MM cells are highly susceptible to simultaneous Chk1 and MEK1/2 inhibition.

  3. Specific IgE Antibodies in Young Children with Atopic Dermatitis--Correlation of Multiple Allergen Simultaneous Immunoblot Test and ImmunoCap System.

    Science.gov (United States)

    Konopka, Ewa; Ceregra, Aldona; Maciorkowska, Elzbieta; Surowska, Barbara; Trojanowska, Ilona; Roszko-Kirpsza, Izabela; Cukrowska, Bozena

    2016-01-01

    Sensitization to food allergens is a common condition in pediatric atopic dermatitis (AD). Recently, the multiple allergen simultaneous test (MAST) allowing for a comprehensive assessment of atopy has been developed, but the usefulness in young AD children is not known. The aim of this study was to determine IgE specificity in AD children using MAST and to compare the results for selected food allergens with the reference ImmunoCap system. The study enrolled 50 children up to 2 years old with a diagnosis of AD. IgE antibodies were measured with the MAST-immunoblots. Children with specific IgE levels ≥ 0.35 kU/L were identified as sensitized to allergens. Most often children were sensitized to food allergens (egg white and yolk, hazelnuts, potato, cow's milk proteins, wheat flour, codfish, and soybean), but a high percentage of them also had IgE antibodies against house dust mites (12%), grass (10%), and birch (10%). Eight percent of children were sensitized to domestic animals (cats and dogs). Almost perfect (kappa index 0.8 - 1.0) and substantial (kappa index 0.6 - 0.8) agreement between MAST and ImmunoCap was found for food allergens except codfish. Pearson's analysis of antibody classes showed a very strong correlation between two methods (r = 0.8 - 1.0) for egg white, hazelnuts, potato, cow's milk proteins, wheat flour, and soybean, and a strong correlation (r = 0.6 - 0.79) was observed for peanut, egg yolk, and codfish. The study showed the frequent occurrence of IgE antibodies against food and airborne and animal allergens in young AD children and confirmed the usefulness of MAST-immunoblots for screening of sensitization in pediatric patients.

  4. Fast and simultaneous monitoring of organic pollutants in a drinking water treatment plant by a multi-analyte biosensor followed by LC-MS validation.

    Science.gov (United States)

    Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià

    2006-04-15

    This work describes the application of an optical biosensor (RIver ANALyser, RIANA) to the simultaneous analysis of three relevant environmental organic pollutants, namely, the pesticides atrazine and isoproturon and the estrogen estrone, in real water samples. This biosensor is based on an indirect inhibition immunoassay which takes place at a chemically modified optical transducer chip. The spatially resolved modification of the transducer surface allows the simultaneous determination of selected target analytes by means of "total internal reflection fluorescence" (TIRF). The performance of the immunosensor method developed was evaluated against a well accepted traditional method based on solid-phase extraction followed by liquid chromatography-mass spectrometry (LC-MS). The chromatographic method was superior in terms of linearity, sensitivity and accuracy, and the biosensor method in terms of repeatability, speed, cost and automation. The application of both methods in parallel to determine the occurrence and removal of atrazine, isoproturon and estrone throughout the treatment process (sand filtration, ozonation, activated carbon filtration and chlorination) in a waterworks showed an overestimation of results in the case of the biosensor, which was partially attributed to matrix and cross-reactivity effects, in spite of the addition of ovalbumin to the sample to minimize matrix interferences. Based on the comparative performance of both techniques, the biosensor emerges as a suitable tool for fast, simple and automated screening of water pollutants without sample pretreatment. To the author's knowledge, this is the first description of the application of the biosensor RIANA in the multi-analyte configuration to the regular monitoring of pollutants in a waterworks.

  5. Validation of the Hirst-Type Spore Trap for Simultaneous Monitoring of Prokaryotic and Eukaryotic Biodiversities in Urban Air Samples by Next-Generation Sequencing.

    Science.gov (United States)

    Núñez, Andrés; Amo de Paz, Guillermo; Ferencova, Zuzana; Rastrojo, Alberto; Guantes, Raúl; García, Ana M; Alcamí, Antonio; Gutiérrez-Bustillo, A Montserrat; Moreno, Diego A

    2017-07-01

    Pollen, fungi, and bacteria are the main microscopic biological entities present in outdoor air, causing allergy symptoms and disease transmission and having a significant role in atmosphere dynamics. Despite their relevance, a method for monitoring simultaneously these biological particles in metropolitan environments has not yet been developed. Here, we assessed the use of the Hirst-type spore trap to characterize the global airborne biota by high-throughput DNA sequencing, selecting regions of the 16S rRNA gene and internal transcribed spacer for the taxonomic assignment. We showed that aerobiological communities are well represented by this approach. The operational taxonomic units (OTUs) of two traps working synchronically compiled >87% of the total relative abundance for bacterial diversity collected in each sampler, >89% for fungi, and >97% for pollen. We found a good correspondence between traditional characterization by microscopy and genetic identification, obtaining more-accurate taxonomic assignments and detecting a greater diversity using the latter. We also demonstrated that DNA sequencing accurately detects differences in biodiversity between samples. We concluded that high-throughput DNA sequencing applied to aerobiological samples obtained with Hirst spore traps provides reliable results and can be easily implemented for monitoring prokaryotic and eukaryotic entities present in the air of urban areas. IMPORTANCE Detection, monitoring, and characterization of the wide diversity of biological entities present in the air are difficult tasks that require time and expertise in different disciplines. We have evaluated the use of the Hirst spore trap (an instrument broadly employed in aerobiological studies) to detect and identify these organisms by DNA-based analyses. Our results showed a consistent collection of DNA and a good concordance with traditional methods for identification, suggesting that these devices can be used as a tool for continuous

  6. Practical Field Calibration of Portable Monitors for Mobile Measurements of Multiple Air Pollutants

    Directory of Open Access Journals (Sweden)

    Chun Lin

    2017-11-01

    Full Text Available To reduce inaccuracies in the measurement of air pollutants by portable monitors it is necessary to establish quantitative calibration relationships against their respective reference analyser. This is usually done under controlled laboratory conditions or one-off static co-location alongside a reference analyser in the field, neither of which may adequately represent the extended use of portable monitors in exposure assessment research. To address this, we investigated ways of establishing and evaluating portable monitor calibration relationships from repeated intermittent deployment cycles over an extended period involving stationary deployment at a reference site, mobile monitoring, and completely switched off. We evaluated four types of portable monitors: Aeroqual Ltd. (Auckland, New Zealand S500 O3 metal oxide and S500 NO2 electrochemical; RTI (Berkeley, CA, USA MicroPEM PM2.5; and, AethLabs (San Francisco, CA, USA AE51 black carbon (BC. Innovations in our study included: (i comparison of calibrations derived from the individual co-locations of a portable monitor against its reference analyser or from all the co-location periods combined into a single dataset; and, (ii evaluation of calibrated monitor estimates during transient measurements with the portable monitor close to its reference analyser at separate times from the stationary co-location calibration periods. Within the ~7 month duration of the study, ‘combined’ calibration relationships for O3, PM2.5, and BC monitors from all co-locations agreed more closely on average with reference measurements than ‘individual’ calibration relationships from co-location deployment nearest in time to transient deployment periods. ‘Individual’ calibrations relationships were sometimes substantially unrepresentative of the ‘combined’ relationships. Reduced quantitative consistency in field calibration relationships for the PM2.5 monitors may have resulted from generally low PM2

  7. Simultaneous determination of components released from dental composite resins in human saliva by liquid chromatography/multiple-stage ion trap mass spectrometry.

    Science.gov (United States)

    Hsu, Wei-Yi; Wang, Ven-Shing; Lai, Chien-Chen; Tsai, Fuu-Jen

    2012-02-01

    Dental composite resins are widely used for fixing teeth; however, the monomers used in dental composite resins have been found to be cytotoxic and genotoxic, namely triethylene glycol dimethacrylate (TEGDMA), urethane dimethacrylate (UDMA), and bisphenol A glycol dimethacrylate (Bis-GMA). In this study, we incubated dental composite resins with human saliva for demonstrating the released monomers and biodegradation products. A simple saliva sample dilution method without purification or derivatization was used for quantification. We found that liquid chromatography coupled with multiple-stage ion trap mass spectrometry (LC-MS(n) ) operated in selected reaction monitoring (SRM) mode was able to separate the three monomers within 10 min. The calibration curves were linear (R² >0.996) over a wide range for each monomer in saliva: TEGDMA, 5-500 ppb; UDMA, 5-100 ppb, and Bis-GMA, 5-700 ppb. Furthermore, several biodegradation products were discovered with data-dependent MS/MS scan techniques. Although TEGMA degradation products have previously been reported, we identified two previously unknown UDMA degradation products. The LC-MS/MS method developed in this study was able to successfully quantify monomers and their principal biodegradation products from dental composite resins in human saliva. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. [Application of simultaneous determination of inorganic ionic species by advanced ion chromatography for water quality monitoring of river water and wastewater].

    Science.gov (United States)

    Nakatani, Nobutake; Kozaki, Daisuke; Tanaka, Kazuhiko

    2012-04-01

    In this study, our recent work on advanced ion chromatographic methods for the simultaneous determination of inorganic ionic species such as common anions (SO4(2-), Cl(-) and NO3(-)) and cations (Na+, NH4+, K+, Mg2+, and Ca2+), nutrients (phosphate and silicate) and hydrogen ion/alkalinity are summarized first. Then, the applications using these methods for monitoring environmental water quality are also presented. For the determination of common anions and cations with nutrients, the separation was successfully performed by a polymethacrylate-based weakly acidic cation-exchange column of TSKgel Super IC-A/C (Tosoh, 150 mm x 6.0 mm i. d.) and a mixture solution of 100 mmol/L ascorbic acid and 4 mmol/L 18-crown-6 as acidic eluent with dual detection of conductivity and spectrophotometry. For the determination of hydrogen ion/alkalinity, the separation was conducted by TSKgel ODS-100Z column (Tosoh, 150 mm x 4.5 mm i. d.) modified with lithium dodecylsulfate and an eluent of 40 mmol/L LiCl/0.1 mmol/L lithium dodecylsulfate/0.05 mmol/L H2SO4 with conductivity detector. The differences of ion concentration between untreated and treated wastewater showed the variation of ionic species during biological treatment process in a sewage treatment plant. Occurrence and distribution of water-quality conditions were related to the bioavailability and human activity in watershed. From these results, our advanced ion chromatographic methods have contributed significantly for water quality monitoring of environmental waters.

  9. WEATHER ON THE NEAREST BROWN DWARFS: RESOLVED SIMULTANEOUS MULTI-WAVELENGTH VARIABILITY MONITORING OF WISE J104915.57–531906.1AB

    Energy Technology Data Exchange (ETDEWEB)

    Biller, Beth A.; Crossfield, Ian J. M.; Mancini, Luigi; Ciceri, Simona; Kopytova, Taisiya G.; Bonnefoy, Mickaël; Deacon, Niall R.; Schlieder, Joshua E.; Buenzli, Esther; Brandner, Wolfgang; Bailer-Jones, Coryn A. L.; Henning, Thomas; Goldman, Bertrand [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Southworth, John [Astrophysics Group, Keele University, Staffordshire, ST5 5BG (United Kingdom); Allard, France; Homeier, Derek; Freytag, Bernd [Centre de Recherche Astrophysique de Lyon, Ecole Normale Supérieure de Lyon, 46 allée d' Italie, F-69364 Lyon cedex 07 (France); Greiner, Jochen [Max-Planck Institute for extraterrestrische Physik, D-85748 Garching, Giessenbachstr (Germany)

    2013-11-20

    We present two epochs of MPG/ESO 2.2 m GROND simultaneous six-band (r'i'z' JHK) photometric monitoring of the closest known L/T transition brown dwarf binary WISE J104915.57–531906.1AB. We report here the first resolved variability monitoring of both the T0.5 and L7.5 components. We obtained 4 hr of focused observations on the night of 2013 April 22 (UT), as well as 4 hr of defocused (unresolved) observations on the night of 2013 April 16 (UT). We note a number of robust trends in our light curves. The r' and i' light curves appear to be anti-correlated with z' and H for the T0.5 component and in the unresolved light curve. In the defocused dataset, J appears correlated with z' and H and anti-correlated with r' and i', while in the focused dataset we measure no variability for J at the level of our photometric precision, likely due to evolving weather phenomena. In our focused T0.5 component light curve, the K band light curve displays a significant phase offset relative to both H and z'. We argue that the measured phase offsets are correlated with atmospheric pressure probed at each band, as estimated from one-dimensional atmospheric models. We also report low-amplitude variability in i' and z' intrinsic to the L7.5 component.

  10. Electrical Neural Stimulation and Simultaneous in Vivo Monitoring with Transparent Graphene Electrode Arrays Implanted in GCaMP6f Mice.

    Science.gov (United States)

    Park, Dong-Wook; Ness, Jared P; Brodnick, Sarah K; Esquibel, Corinne; Novello, Joseph; Atry, Farid; Baek, Dong-Hyun; Kim, Hyungsoo; Bong, Jihye; Swanson, Kyle I; Suminski, Aaron J; Otto, Kevin J; Pashaie, Ramin; Williams, Justin C; Ma, Zhenqiang

    2018-01-23

    Electrical stimulation using implantable electrodes is widely used to treat various neuronal disorders such as Parkinson's disease and epilepsy and is a widely used research tool in neuroscience studies. However, to date, devices that help better understand the mechanisms of electrical stimulation in neural tissues have been limited to opaque neural electrodes. Imaging spatiotemporal neural responses to electrical stimulation with minimal artifact could allow for various studies that are impossible with existing opaque electrodes. Here, we demonstrate electrical brain stimulation and simultaneous optical monitoring of the underlying neural tissues using carbon-based, fully transparent graphene electrodes implanted in GCaMP6f mice. Fluorescence imaging of neural activity for varying electrical stimulation parameters was conducted with minimal image artifact through transparent graphene electrodes. In addition, full-field imaging of electrical stimulation verified more efficient neural activation with cathode leading stimulation compared to anode leading stimulation. We have characterized the charge density limitation of capacitive four-layer graphene electrodes as 116.07-174.10 μC/cm 2 based on electrochemical impedance spectroscopy, cyclic voltammetry, failure bench testing, and in vivo testing. This study demonstrates the transparent ability of graphene neural electrodes and provides a method to further increase understanding and potentially improve therapeutic electrical stimulation in the central and peripheral nervous systems.

  11. Simultaneous monitoring of oxidation, deamidation, isomerization, and glycosylation of monoclonal antibodies by liquid chromatography-mass spectrometry method with ultrafast tryptic digestion.

    Science.gov (United States)

    Wang, Yi; Li, Xiaojuan; Liu, Yan-Hui; Richardson, Daisy; Li, Huijuan; Shameem, Mohammed; Yang, Xiaoyu

    Monoclonal antibodies are subjected to a wide variety of post-translational modifications (PTMs) that cause structural heterogeneity. Characterization and control of these modifications or quality attributes are critical to ensure antibody quality and to define any potential effects on the ultimate safety and potency of antibody therapeutics. The biopharmaceutical industry currently uses numerous tools to analyze these quality attributes individually, which requires substantial time and resources. Here, we report a simple and ultrafast bottom-up liquid chromatography-mass spectrometry (uLC-MS) method with 5 min tryptic digestion to simultaneously analyze multiple modifications, including oxidation, deamidation, isomerization, glycation, glycosylation, and N-terminal pyro-glutamate formation, which can occur during antibody production in mammalian cell culture, during purification and/or on storage. Compared to commonly used preparation procedures, this uLC-MS method eliminates assay artifacts of falsely-increased Met oxidation, Asp isomerization, and Asn deamidation, a problem associated with long digestion times in conventional LC-MS methods. This simple, low artifact multi-attribute uLC-MS method can be used to quickly and accurately analyze samples at any stage of antibody drug development, in particular for clone and media selection during cell culture development.

  12. Rapid determination of eight bioactive alkaloids in Portulaca oleracea L. by the optimal microwave extraction combined with positive-negative conversion multiple reaction monitor (+/-MRM) technology.

    Science.gov (United States)

    Liang, Xiao; Tian, Jinlong; Li, Lingzhi; Gao, Jun; Zhang, Qingyi; Gao, Pinyi; Song, Shaojiang

    2014-03-01

    A rapid and reliable microwave extraction and the triple quadrupole-linear ion trap mass spectrometry method was developed and validated for the determination of eight alkaloids in Portulaca oleracea L. The optimal microwave extraction (MWE) condition was performed at 60 °C for 12 min with ethanol-water (70:30, v/v) as the extracting solvent, and the solvent to solid ratio was 30:1. The alkaloids were first detected simultaneously by electrospray ionization tandem mass spectrometry under positive-negative conversion multiple reaction monitor ((+/-)MRM) technique. With investigating three different columns, samples were separated in only 8 min on a Waters ACQUITY UPLC HSS T3 (50 × 2.1 mm(2), 1.8 μm) column using acetonitrile and formic acid-water solution as a mobile phase with a flow rate at 0.2 mL/min. All calibration curves showed good linearity (r>0.999) within the test ranges. The method developed was validated with acceptable sensitivity, intra- and inter-day precision, reproducibility, and extraction recoveries. It was successfully applied to the determination of eight alkaloids in Portulaca oleracea L. from different sources and different harvest periods. The method also provide a reference for extraction and determination of alkaloids in other complex systems. © 2013 Elsevier B.V. All rights reserved.

  13. Monitoring the Effect of Facilitation Physiotherapy in Multiple Sclerosis using Functional Magnetic Resonance Imaging

    Czech Academy of Sciences Publication Activity Database

    Procházková, M.; Řasová, K.; Tintěra, J.; Martinková, Patrícia; Procházka, A.

    2014-01-01

    Roč. 20, č. 7 (2014), s. 1003-1004 ISSN 1352-4585. [RIMS 2014. Annual Conference on Rehabilitation in Multiple Sclerosis /19./. 06.06.2014-07.06.2014, Brighton] Institutional support: RVO:67985807 Subject RIV: BB - Applied Statistics, Operational Research

  14. Natalizumab treatment for multiple sclerosis: updated recommendations for patient selection and monitoring

    DEFF Research Database (Denmark)

    Kappos, Ludwig; Bates, David; Edan, Gilles

    2011-01-01

    Natalizumab, a highly specific a4-integrin antagonist, is approved for treatment of patients with active relapsing-remitting multiple sclerosis (RRMS). It is generally recommended for individuals who have not responded to a currently available first-line disease-modifying therapy or who have very...

  15. Networking Multiple Autonomous Air and Ocean Vehicles for Oceanographic Research and Monitoring

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Rajan, K.

    2013-12-01

    Autonomous underwater and surface vessels (AUVs and ASVs) are coming into wider use as components of oceanographic research, including ocean observing systems. Unmanned airborne vehicles (UAVs) are now available at modest cost, allowing multiple UAVs to be deployed with multiple AUVs and ASVs. For optimal use good communication and coordination among vehicles is essential. We report on the use of multiple AUVs networked in communication with multiple UAVs. The UAVs are augmented by inferential reasoning software developed at MBARI that allows UAVs to recognize oceanographic fronts and change their navigation and control. This in turn allows UAVs to automatically to map frontal features, as well as to direct AUVs and ASVs to proceed to such features and conduct sampling via onboard sensors to provide validation for airborne mapping. ASVs can also act as data nodes for communication between UAVs and AUVs, as well as collecting data from onboard sensors, while AUVs can sample the water column vertically. This allows more accurate estimation of phytoplankton biomass and productivity, and can be used in conjunction with UAV sampling to determine air-sea flux of gases (e.g. CO2, CH4, DMS) affecting carbon budgets and atmospheric composition. In particular we describe tests in July 2013 conducted off Sesimbra, Portugal in conjunction with the Portuguese Navy by the University of Porto and MBARI with the goal of tracking large fish in the upper water column with coordinated air/surface/underwater measurements. A thermal gradient was observed in the infrared by a low flying UAV, which was used to dispatch an AUV to obtain ground truth to demonstrate the event-response capabilities using such autonomous platforms. Additional field studies in the future will facilitate integration of multiple unmanned systems into research vessel operations. The strength of hardware and software tools described in this study is to permit fundamental oceanographic measurements of both ocean

  16. Branched alkanes from ancient and modern sediments: isomer discrimination by GC/MS with multiple reaction monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Summons, R.E.

    1987-01-01

    Linked scanning of a tandem sector mass spectrometer has been used to identify abundant, first field free region (FFR1) unimolecular fragmentations in branched and isoprenoid hydrocarbons. The most intense, structure-specific reactions were selected to establish multiple reaction monitoring (MRM) parameters for GC/MS analysis. This methodology has been used to study the identify of co-eluting and closely eluting hydrocarbon biomarkers from modern and ancient sediments and from extant microorganisms. Some sediments of Cambrian and Proterozoic age have been found to contain suites of monomethylalkanes with all possible isomers present and with little apparent preference for the site of branching.

  17. Stepped MS(All) Relied Transition (SMART): An approach to rapidly determine optimal multiple reaction monitoring mass spectrometry parameters for small molecules.

    Science.gov (United States)

    Ye, Hui; Zhu, Lin; Wang, Lin; Liu, Huiying; Zhang, Jun; Wu, Mengqiu; Wang, Guangji; Hao, Haiping

    2016-02-11

    Multiple reaction monitoring (MRM) is a universal approach for quantitative analysis because of its high specificity and sensitivity. Nevertheless, optimization of MRM parameters remains as a time and labor-intensive task particularly in multiplexed quantitative analysis of small molecules in complex mixtures. In this study, we have developed an approach named Stepped MS(All) Relied Transition (SMART) to predict the optimal MRM parameters of small molecules. SMART requires firstly a rapid and high-throughput analysis of samples using a Stepped MS(All) technique (sMS(All)) on a Q-TOF, which consists of serial MS(All) events acquired from low CE to gradually stepped-up CE values in a cycle. The optimal CE values can then be determined by comparing the extracted ion chromatograms for the ion pairs of interest among serial scans. The SMART-predicted parameters were found to agree well with the parameters optimized on a triple quadrupole from the same vendor using a mixture of standards. The parameters optimized on a triple quadrupole from a different vendor was also employed for comparison, and found to be linearly correlated with the SMART-predicted parameters, suggesting the potential applications of the SMART approach among different instrumental platforms. This approach was further validated by applying to simultaneous quantification of 31 herbal components in the plasma of rats treated with a herbal prescription. Because the sMS(All) acquisition can be accomplished in a single run for multiple components independent of standards, the SMART approach are expected to find its wide application in the multiplexed quantitative analysis of complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Development of monitor for multiple beta-ray nuclides in liquid radioactive waste (IV)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Kyu; Nam, Uk Won; Seon, K. I.; Kong, K. N.; Son, J. D.; Chin, H.; Park, J. H.; Yuk, I. S.; Han, W. Y. [Korea Astronomy and Space Science Institute, Daejeon (Korea, Republic of)

    2004-02-15

    In the 4{sup th} fiscal year, the performance of the system developed in previous year have been stablilized. An automatic mixer system to mix the liquid radioactive waste with the liquid scintillator was designed and manufactured to make continuous monitoring possible. Mechanical systems for the automatic transfer, injection of radioactive samples, and for sealing sample bottle and its attachment on detector system have been designed and developed for completely integrated system, The experimental has been performed for the radioactive analysis by using the system. The measured data are transferred to central computer, which controls the monitoring system, through the RS-232 communication protocol. A software for host personal computer was developed for the control and analysis of the integrated system.

  19. Vibration monitoring of carbon fiber composites by multiple fiber optic sensors

    Science.gov (United States)

    Olivero, Massimo; Perrone, Guido; Vallan, Alberto; Chen, Wei; Tosi, Daniele

    2014-05-01

    This work presents the comparison between the fiber Bragg grating technology and a vibration-measurement technique based on the detection of polarization rotation (polarimetric sensor) in a standard optical fiber, applied to the dynamic structural monitoring of carbon reinforced composites for the automotive industry. A carbon reinforced composite test plate in a 4-layer configuration was equipped with fiber Bragg gratings and polarimetric fiber sensors, then it was mechanically stressed by static and dynamic loads while monitoring the sensors response. The fiber Bragg grating setup exhibited 1.15+/-0.0016 pm/kg static load response and reproduced dynamic excitation with 0.1% frequency uncertainty, while the polarimetric sensing system exhibited a sensitivity of 1.74+/-0.001 mV/kg and reproduced the dynamic excitation with 0.5% frequency uncertainty. It is shown that the polarimetric sensor technology represents a cheap yet efficient alternative to the fiber Bragg grating sensors in the case of vibration-monitoring of small structures at high frequency.

  20. Natalizumab treatment for multiple sclerosis: updated recommendations for patient selection and monitoring

    DEFF Research Database (Denmark)

    Kappos, Ludwig; Bates, David; Edan, Gilles

    2011-01-01

    Natalizumab, a highly specific α4-integrin antagonist, is approved for treatment of patients with active relapsing-remitting multiple sclerosis (RRMS). It is generally recommended for individuals who have not responded to a currently available first-line disease-modifying therapy or who have very......, based on additional long-term follow-up of clinical studies and post-marketing observations, including appropriate patient selection and management recommendations.......Natalizumab, a highly specific α4-integrin antagonist, is approved for treatment of patients with active relapsing-remitting multiple sclerosis (RRMS). It is generally recommended for individuals who have not responded to a currently available first-line disease-modifying therapy or who have very...... active disease. The expected benefits of natalizumab treatment have to be weighed against risks, especially the rare but serious adverse event of progressive multifocal leukoencephalopathy. In this Review, we revisit and update previous recommendations on natalizumab for treatment of patients with RRMS...

  1. Scanning an individual monitoring database for multiple occurrences using bi-gram analysis

    International Nuclear Information System (INIS)

    Van Dijk, J. W. E.

    2007-01-01

    Maintaining the integrity of the databases is one of the important aspects of quality assurance at individual monitoring services and national dose registers. This paper presents a method for finding and preventing the occurrence of duplicate entries in the databases that can occur, e.g. because of a variable spelling or misspelling of the name. The method is based on bi-gram text analysis techniques. The methods can also be used for retrieving dose data in historical databases in the framework of dose reconstruction efforts of persons of whom the spelling of the name as originally entered, possibly decades ago, is uncertain. (authors)

  2. Structural health monitoring and damage assessment using measured FRFs from multiple sensors. Part I. The indicator of correlation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Zang, C.; Friswell, M.I. [Dept. of Aerospace Engineering, Univ. of Bristol, Bristol (United Kingdom); Imregun, M. [Dept. of Mechanical Engineering, Imperial Coll., London (United Kingdom)

    2003-07-01

    This paper presents two criteria for correlating measured frequency responses from multiple sensors and proposes to use them as indicators for structural damage detection. The first criterion is a global shape correlation (GSC) function that is sensitive to mode shape differences but not to relative scales. The second criterion, a global amplitude correlation (GAC) function, is based on actual response amplitudes. Both correlation criteria are a function of frequency and uniquely map a set of complex responses to a real scalar between zero and unity. The averaged integrations of GSC and GAC functions along the frequency points over the measurement range, also called damage indicators, are used to describe the correlation between two sets of vibration data. When a structure state remains unchanged, both correlation criteria are as close to unity simultaneously. Otherwise, the correlation with the reference data will be decreased with changes of structure states. Using GSC and GAC functions has the advantage of being able to deal with incomplete measurements. Also, all available response data are used and hence there is no critical selection of frequency points for damage detection. The above correlation criteria were applied to a bookshelf structure and various cases such as undamaged states, damage locations (single and multiple), damage levels, as well as environmental variability are discussed. As expected, it was found that indicators of correlation criteria were able to identify all various cases correctly. (orig.)

  3. Challenges in striving to simultaneously achieve multiple resource allocation goals: the pan-Canadian Oncology Drug Review (pCODR) example.

    Science.gov (United States)

    McDonald, Heather; Charles, Cathy; Elit, Laurie; Gafni, Amiram

    2016-01-01

    The pan-Canadian Oncology Drug Review (pCODR) makes recommendations to Canada's provinces and territories (except Quebec) to guide their cancer drug funding decisions. The objective of this paper is to explore, using an economic perspective and the pCODR as an example, the challenges associated with striving to simultaneously achieve the goals of maximizing health benefits with available resources and improving access to a more consistent standard of care across Canada. The first challenge concerns how to interpret the goals in order to determine how resources should be allocated to achieve each goal. The second challenge relates to whether, if pursued simultaneously, both goals can be achieved to the same extent that each goal could have been achieved alone with the same available resources. Regarding the first challenge, we illustrate that, due to a lack of definitional clarity, it is difficult to determine exactly how resources should be allocated in order to achieve the goal of improving access to a more consistent standard of care across Canada. Regarding the second challenge, we illustrate that choosing to strive for both of the pCODR goals simultaneously will likely be associated with tradeoffs in the extent to which one or both goals can be achieved (relative to what could have been achieved for each goal alone with the same available resources). We suggest that, if the pCODR and the provincial drug plan decision-makers it supports want to strive for both goals simultaneously, they must prioritize the goals and explicitly identify the tradeoffs associated with the prioritization. This will ensure that the consequences of striving to simultaneously achieve both goals are explicit, transparent, and predictable for provincial drug plan decision-makers, physicians, patients, caregivers, and society as a whole.

  4. Prolongation of the deployment and monitoring of a multiple oscillating water column wave energy converter

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, F.; Chudley, J.; Dai, Y.M.

    2003-07-01

    This report summarises the findings of a project to prolong the sea trials of a multiple oscillating water column wave energy converter (MOWC) device for another 12 months to obtain further data. The objectives of the project include the evaluation of the ability of the MOWC to generate reliable energy to produce electricity, the estimation of the conversion efficiency, and the identification of improvements to increase the conversion efficiency, Details are given of the analysis of the sea trials data, and the performance of the broadband oscillating water column prototype.

  5. The application of multiple reaction monitoring to assess ApoA-I methionine oxidations in diabetes and cardiovascular disease

    Directory of Open Access Journals (Sweden)

    Hussein N. Yassine

    2014-12-01

    Full Text Available The oxidative modification of apolipoprotein A-I’s methionine148 (M148 is associated with defective HDL function in vitro. Multiple reaction monitoring (MRM is a mass spectrometric technique that can be used to quantitate post-translational modifications. In this study, we developed an MRM assay to monitor the abundance ratio of the peptide containing oxidized M148 to the native peptide in ApoA-I. Measurement of the oxidized-to-unoxidized-M148 ratio was reproducible (CV < 5%. The extent of methionine M148 oxidation in the HDL of healthy controls, and type 2 diabetic participants with and without prior cardiovascular events (CVD were then examined. The results suggest a significant increase in the relative ratio of the peptide containing oxidized M148 to the unmodified peptide in the HDL of participants with diabetes and CVD (p < 0.001, compared to participants without CVD. Monitoring the abundance ratio of the peptides containing oxidized and unoxidized M148 by MRM provides a means of examining the relationship between M148 oxidation and vascular complications in CVD.

  6. Monitoring multiple myeloma by idiotype-specific peptide binders of tumor-derived exosomes.

    Science.gov (United States)

    Iaccino, Enrico; Mimmi, Selena; Dattilo, Vincenzo; Marino, Fabiola; Candeloro, Patrizio; Di Loria, Antonio; Marimpietri, Danilo; Pisano, Antonio; Albano, Francesco; Vecchio, Eleonora; Ceglia, Simona; Golino, Gaetanina; Lupia, Antonio; Fiume, Giuseppe; Quinto, Ileana; Scala, Giuseppe

    2017-10-13

    Tumor-derived exosomes (TDEs) play a pivotal role in tumor establishment and progression, and are emerging biomarkers for tumor diagnosis in personalized medicine. To date, there is a lack of efficient technology platforms for exosome isolation and characterization. Multiple myeloma (MM) is an incurable B-cell malignancy due to the rapid development of drug-resistance. MM-released exosomes express the immunoglobulin B-cell receptor (Ig-BCR) of the tumor B-cells, which can be targeted by Idiotype-binding peptides (Id-peptides). In this study, we analyzed the production of MM-released exosomes in the murine 5T33MM multiple myeloma model as biomarkers of tumor growth. To this end, we selected Id-peptides by screening a phage display library using as bait the Ig-BCR expressed by 5T33MM cells. By FACS, the FITC-conjugated Id-peptides detected the MM-released exosomes in the serum of 5T33MM-engrafted mice, levels of which are correlated with tumor progression at an earlier time point compared to serum paraprotein. These results indicate that Id-peptide-based recognition of MM-released exosomes may represent a very sensitive diagnostic approach for clinical evaluation of disease progression.

  7. Simultaneous radiochemotherapy

    International Nuclear Information System (INIS)

    Dunst, J.; Sauer, R.

    1993-01-01

    Simultaneous radiochemotherapy (RCT) means the simultaneous application of radiotherapy and chemotherapy. The major objective of this approach is the improvement of local control. On the cellular level, three types of interactions may be distinguished: Additivity, synergism, and sensibilization. The main type of interaction seems to be a simple additive effect. The clinical effect of a simultaneous chemotherapy depends mainly on the cytotoxic action of the drug itself and not on radiosensibilization. Therefore, effective chemotherapeutic drugs are to be delivered in cytotoxic dosages in RCT protocols. Compromises in radiotherapy as the main modality should be avoided. Recent clinical data have shown that simultaneous radiochemotherapy may yield heigh remission rates in a number of tumor entities (e.g. anal cancer, bladder cancer, head and neck cancer). This seems to improve local control as compared to radiotherapy alone. In some tumors (e.g. head and neck, esophagus), survival may be improved also. However, several questions require future detailed clinical trials. These questions include the value of simultaneous radiochemotherapy compared to optimal fractionation schemes, the clear definition of subgroups of patients with benefit by radiochemotherapy and the optimal dose intensity of cytotoxic drugs. (orig.) [de

  8. Traffic intensity monitoring using multiple object detection with traffic surveillance cameras

    Science.gov (United States)

    Hamdan, H. G. Muhammad; Khalifah, O. O.

    2017-11-01

    Object detection and tracking is a field of research that has many applications in the current generation with increasing number of cameras on the streets and lower cost for Internet of Things(IoT). In this paper, a traffic intensity monitoring system is implemented based on the Macroscopic Urban Traffic model is proposed using computer vision as its source. The input of this program is extracted from a traffic surveillance camera which has another program running a neural network classification which can identify and differentiate the vehicle type is implanted. The neural network toolbox is trained with positive and negative input to increase accuracy. The accuracy of the program is compared to other related works done and the trends of the traffic intensity from a road is also calculated. relevant articles in literature searches, great care should be taken in constructing both. Lastly the limitation and the future work is concluded.

  9. In vivo imaging of system xc- as a novel approach to monitor multiple sclerosis

    International Nuclear Information System (INIS)

    Martin, Abraham; Szczupak, Boguslaw; Arrieta, Ander; Vazquez-Villoldo, Nuria; Soria, Federico N.; Domercq, Maria; Matute, Carlos; Gomez-Vallejo, Vanessa; Llop, Jordi; Padro, Daniel; Plaza-Garcia, Sandra; Reese, Torsten

    2016-01-01

    Glutamate excitotoxicity contributes to oligodendroglial and axonal damage in multiple sclerosis pathology. Extracellular glutamate concentration in the brain is controlled by cystine/glutamate antiporter (system xc-), a membrane antiporter that imports cystine and releases glutamate. Despite this, the system xc - activity and its connection to the inflammatory reaction in multiple sclerosis (MS) is largely unknown. Longitudinal in vivo magnetic resonance (MRI) and positron emission tomography (PET) imaging studies with 2-[ 18 F]Fluoro-2-deoxy-D-glucose ([ 18 F]FDG), [ 11 C]-(R)-1-(2-chlorophenyl)-N-methyl-N-1(1-methylpropyl) -3-isoquinolinecarbox amide ([ 11 C]PK11195) and (4S)-4-(3- 18 F-fluoropropyl)-L-glutamate ([ 18 F]FSPG) were carried out during the course of experimental autoimmune encephalomyelitis (EAE) induction in rats. [ 18 F]FSPG showed a significant increase of system xc - function in the lumbar section of the spinal cord at 14 days post immunization (dpi) that stands in agreement with the neurological symptoms and ventricle edema formation at this time point. Likewise, [ 18 F]FDG did not show significant changes in glucose metabolism throughout central nervous system and [ 11 C]PK11195 evidenced a significant increase of microglial/macrophage activation in spinal cord and cerebellum 2 weeks after EAE induction. Therefore, [ 18 F]FSPG showed a major capacity to discriminate regions of the central nervous system affected by the MS in comparison to [ 18 F]FDG and [ 11 C]PK11195. Additionally, clodronate-treated rats showed a depletion in microglial population and [ 18 F]FSPG PET signal in spinal cord confirming a link between neuroinflammatory reaction and cystine/glutamate antiporter activity in EAE rats. Altogether, these results suggest that in vivo PET imaging of system xc - could become a valuable tool for the diagnosis and treatment evaluation of MS. (orig.)

  10. Long-term monitoring of atmospheric PCDD/Fs at Mount Lulin during spring season: PCDD/F source apportionment through a simultaneous measurement in Southeast Asia.

    Science.gov (United States)

    Hung, Ngo Tuan; Li, Chueh Ting; Wang, Sheng Hsiang; Ou-Yang, Chang-Feng; Lin, Chuan-Yao; Lee, Chung-Te; Lin, Neng-Huei; Chi, Kai Hsien

    2017-10-01

    A long term assessment of atmospheric polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) at Mt. Lulin, located in center of Taiwan was carried out from 2008 to 2013 (n = 81) assuming Mt. Lulin to be background area. During monitoring processes, PCDD/F samples collected in the field occasionally reached high concentration. To investigate this situation, simultaneous sample collection was carried out in Southeast Asia countries (i.e., Vietnam and Thailand) and Taiwan in 2013. The average concentration of atmospheric PCDD/Fs in biomass-burning source regions, namely Son La and Doi Ang Khang were 19.8 ± 12.1 fg I-TEQ m -3 (n = 19) and 17.8 ± 12.4 fg I-TEQ m -3 (n = 20), respectively. In the downwind area of Mt. Lulin, the average concentration of PCDD/Fs was found to be 4.64 ± 3.77 fg I-TEQ m -3 (n = 18). PCDD/F concentration in the source region was much higher than that in the downwind region. On March 19, 2013, the atmospheric PCDD/F concentrations increased dramatically from 7.71 to 484 fg I-TEQ m -3 at Mt. Lulin, which many times exceeded that of assumed source region in Southeast Asia. Moreover, mainland Southeast Asia and the southeast coast of China was suspected to be the main contributors of atmospheric PCDD/Fs and biomass markers, such as nonsea-salt K + and NH 4 + , during the spring. WRF-Chem and Potential Source Contribution Function (PSCF) simulations have confirmed this correlation. It can be concluded that atmospheric PCDD/Fs observed at Mt. Lulin during spring mostly derived from the air mass transport not only from Southeast Asia but also the southeast coast of China. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Liquid chromatography-electrospray ionization tandem mass spectrometry and dynamic multiple reaction monitoring method for determining multiple pesticide residues in tomato.

    Science.gov (United States)

    Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L

    2015-05-15

    A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. In vivo imaging of system xc- as a novel approach to monitor multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Abraham; Szczupak, Boguslaw; Arrieta, Ander [CIC biomaGUNE, Molecular Imaging Unit, San Sebastian (Spain); Vazquez-Villoldo, Nuria; Soria, Federico N.; Domercq, Maria; Matute, Carlos [University of the Basque Country, Department of Neurosciences, Leioa (Spain); UPV/EHU, Achucarro Basque Center for Neuroscience, Zamudio (Spain); Centro de Investigacion Biomedica en Red de Enfermedades Neurodegenerativas (CIBERNED), Instituto de Salud Carlos III, Leioa (Spain); Gomez-Vallejo, Vanessa; Llop, Jordi [CIC biomaGUNE, Molecular Imaging Unit, San Sebastian (Spain); CIC biomaGUNE, Radiochemistry and Nuclear Imaging, San Sebastian (Spain); Padro, Daniel; Plaza-Garcia, Sandra; Reese, Torsten [CIC biomaGUNE, Molecular Imaging Unit, San Sebastian (Spain); CIC biomaGUNE, Magnetic Resonance Imaging, San Sebastian (Spain)

    2016-06-15

    Glutamate excitotoxicity contributes to oligodendroglial and axonal damage in multiple sclerosis pathology. Extracellular glutamate concentration in the brain is controlled by cystine/glutamate antiporter (system xc-), a membrane antiporter that imports cystine and releases glutamate. Despite this, the system xc{sup -} activity and its connection to the inflammatory reaction in multiple sclerosis (MS) is largely unknown. Longitudinal in vivo magnetic resonance (MRI) and positron emission tomography (PET) imaging studies with 2-[{sup 18}F]Fluoro-2-deoxy-D-glucose ([{sup 18}F]FDG), [{sup 11}C]-(R)-1-(2-chlorophenyl)-N-methyl-N-1(1-methylpropyl) -3-isoquinolinecarbox amide ([{sup 11}C]PK11195) and (4S)-4-(3-{sup 18}F-fluoropropyl)-L-glutamate ([{sup 18}F]FSPG) were carried out during the course of experimental autoimmune encephalomyelitis (EAE) induction in rats. [{sup 18}F]FSPG showed a significant increase of system xc{sup -} function in the lumbar section of the spinal cord at 14 days post immunization (dpi) that stands in agreement with the neurological symptoms and ventricle edema formation at this time point. Likewise, [{sup 18}F]FDG did not show significant changes in glucose metabolism throughout central nervous system and [{sup 11}C]PK11195 evidenced a significant increase of microglial/macrophage activation in spinal cord and cerebellum 2 weeks after EAE induction. Therefore, [{sup 18}F]FSPG showed a major capacity to discriminate regions of the central nervous system affected by the MS in comparison to [{sup 18}F]FDG and [{sup 11}C]PK11195. Additionally, clodronate-treated rats showed a depletion in microglial population and [{sup 18}F]FSPG PET signal in spinal cord confirming a link between neuroinflammatory reaction and cystine/glutamate antiporter activity in EAE rats. Altogether, these results suggest that in vivo PET imaging of system xc{sup -} could become a valuable tool for the diagnosis and treatment evaluation of MS. (orig.)

  13. Multiple sulfur isotopes monitor fluid evolution of an Archean orogenic gold deposit

    Science.gov (United States)

    LaFlamme, Crystal; Sugiono, Dennis; Thébaud, Nicolas; Caruso, Stefano; Fiorentini, Marco; Selvaraja, Vikraman; Jeon, Heejin; Voute, François; Martin, Laure

    2018-02-01

    The evolution of a gold-bearing hydrothermal fluid from its source to the locus of gold deposition is complex as it experiences rapid changes in thermochemical conditions during ascent through the crust. Although it is well established that orogenic gold deposits are generated during time periods of abundant crustal growth and/or reworking, the source of fluid and the thermochemical processes that control gold precipitation remain poorly understood. In situ analyses of multiple sulfur isotopes offer a new window into the relationship between source reservoirs of Au-bearing fluids and the thermochemical processes that occur along their pathway to the final site of mineralisation. Whereas δ34S is able to track changes in the evolution of the thermodynamic conditions of ore-forming fluids, Δ33S is virtually indelible and can uniquely fingerprint an Archean sedimentary reservoir that has undergone mass independent fractionation of sulfur (MIF-S). We combine these two tracers (δ34S and Δ33S) to characterise a gold-bearing laminated quartz breccia ore zone and its sulfide-bearing alteration halo in the (+6 Moz Au) structurally-controlled Archean Waroonga deposit located in the Eastern Goldfields Superterrane of the Yilgarn Craton, Western Australia. Over 250 analyses of gold-associated sulfides yield a δ34S shift from what is interpreted as an early pre-mineralisation phase, with chalcopyrite-pyrrhotite (δ34S = +0.7‰ to +2.9‰) and arsenopyrite cores (δ34S = ∼-0.5‰), to a syn-mineralisation stage, reflected in Au-bearing arsenopyrite rims (δ34S = -7.6‰ to +1.5‰). This shift coincides with an unchanging Δ33S value (Δ33S = +0.3‰), both temporally throughout the Au-hosting hydrothermal sulfide paragenesis and spatially across the Au ore zone. These results indicate that sulfur is at least partially recycled from MIF-S-bearing Archean sediments. Further, the invariant nature of the observed MIF-S signature demonstrates that sulfur is derived from a

  14. Seeing beyond monitors-Critical care nurses' multiple skills in patient observation: Descriptive qualitative study.

    Science.gov (United States)

    Alastalo, Mika; Salminen, Leena; Lakanmaa, Riitta-Liisa; Leino-Kilpi, Helena

    2017-10-01

    The aim of this study was to provide a comprehensive description of multiple skills in patient observation in critical care nursing. Data from semi-structured interviews were analysed using thematic analysis. Experienced critical care nurses (n=20) from three intensive care units in two university hospitals in Finland. Patient observation skills consist of: information gaining skills, information processing skills, decision-making skills and co-operation skills. The first three skills are integrated in the patient observation process, in which gaining information is a prerequisite for processing information that precedes making decisions. Co-operation has a special role as it occurs throughout the process. This study provided a comprehensive description of patient observation skills related to the three-phased patient observation process. The findings contribute to clarifying this part of the competence. The description of patient observation skills may be applied in both clinical practice and education as it may serve as a framework for orientation, ensuring clinical skills and designing learning environments. Based on this study, patient observation skills can be recommended to be included in critical care nursing education, orientation and as a part of critical care nurses' competence evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Assessing and monitoring of urban vegetation using multiple endmember spectral mixture analysis

    Science.gov (United States)

    Zoran, M. A.; Savastru, R. S.; Savastru, D. M.

    2013-08-01

    During last years urban vegetation with significant health, biological and economical values had experienced dramatic changes due to urbanization and human activities in the metropolitan area of Bucharest in Romania. We investigated the utility of remote sensing approaches of multiple endmember spectral mixture analysis (MESMA) applied to IKONOS and Landsat TM/ETM satellite data for estimating fractional cover of urban/periurban forest, parks, agricultural vegetation areas. Because of the spectral heterogeneity of same physical features of urban vegetation increases with the increase of image resolution, the traditional spectral information-based statistical method may not be useful to classify land cover dynamics from high resolution imageries like IKONOS. So we used hierarchy tree classification method in classification and MESMA for vegetation land cover dynamics assessment based on available IKONOS high-resolution imagery of Bucharest town. This study employs thirty two endmembers and six hundred and sixty spectral models to identify all Earth's features (vegetation, water, soil, impervious) and shade in the Bucharest area. The mean RMS error for the selected vegetation land cover classes range from 0.0027 to 0.018. The Pearson correlation between the fraction outputs from MESMA and reference data from all IKONOS images 1m panchromatic resolution data for urban/periurban vegetation were ranging in the domain 0.7048 - 0.8287. The framework in this study can be applied to other urban vegetation areas in Romania.

  16. Simultaneous monitoring of biofilm growth, microbial activity, and inorganic deposits on surfaces with an in situ, online, real-time, non-destructive, optical sensor.

    Science.gov (United States)

    Strathmann, Martin; Mittenzwey, Klaus-Henrik; Sinn, Gert; Papadakis, Wassilios; Flemming, Hans-Curt

    2013-01-01

    Deposits on surfaces in water-bearing systems, also known as 'fouling', can lead to substantial losses in the performance of industrial processes as well as a decreased product quality. Early detection and localization of such deposits can, to a considerable extent, save such losses. However, most of the surfaces that become fouled, for example, in process water pipes, membrane systems, power plants, and food and beverage industries, are difficult to access and analyses conducted on the water phase do not reveal the site or extent of deposits. Furthermore, it is of interest to distinguish biological from non-biological deposits. Although they usually occur together, different countermeasures are necessary. Therefore, sensors are required that indicate the development of surface fouling in real-time, non-destructively, and in situ, preferably allowing for discrimination between chemical and/or biological deposits. In this paper, an optical deposit sensor is presented which fulfills these requirements. Based on multiple fluorescence excitation emission matrix analysis, it detects autofluorescence of amino acids as indicators of biomass. Autofluorescence of nicotinamide adenine dinucleotide + hydrogen is interpreted as an indicator of biological activity, thus it acts as a viability marker, making the method suited for assessing the efficacy of disinfection treatments. Scattering signals from abiotic deposits such as calcium carbonate or corrosion products can clearly be distinguished from biotic substances and monitored separately. The sensor provides an early warning of fouling, allowing for timely countermeasures to be deployed. It also provides an assessment of the success of cleaning treatments and is a promising tool for integrated antifouling strategies.

  17. Magnetic resonance imaging in monitoring of treatment of multiple sclerosis; Zastosowanie metody rezonansu magnetycznego w monitorowaniu leczenia stwardnienia rozsianego

    Energy Technology Data Exchange (ETDEWEB)

    Bekiesinska-Figatowska, M.; Walecki, J.; Stelmasiak, Z. [Zaklad Diagnostyki Obrazowej, Centralny Szpital Kolejowy i Centrum Medyczne Ksztalcenia Podyplomowego, Miedzylesie (Poland)]|[Centrum Naukowo-Kliniczne and Zespol Naukowo Badawczy Chorob Demielinizacyjnych, Akademia Medyczna, Lublin (Poland)

    1996-12-31

    The purpose of the study was to establish the value of MR in monitoring of treatment of multiple sclerosis with new drug 2-CDA and placebo. 83 patients (51 women, 32 men) were examined - 81 of them twice, 66 - three times: before and after 6 and 12 courses of treatment. Toshiba MRT50A machine was used. After the first 6 courses of treatment the number of new plaques was twice as big in placebo group than in 2-CDA group. After 12 courses it turned out that a certain inhibitory influence of 2-CDA on new plaques` appearance was more evident after 15 than 3 months after the end of its administration. This may indicate the delayed action of 2-CDA but requires further investigation. (author) 8 refs, 2 figs, 7 tabs

  18. MRMer, an interactive open source and cross-platform system for data extraction and visualization of multiple reaction monitoring experiments.

    Science.gov (United States)

    Martin, Daniel B; Holzman, Ted; May, Damon; Peterson, Amelia; Eastham, Ashley; Eng, Jimmy; McIntosh, Martin

    2008-11-01

    Multiple reaction monitoring (MRM) mass spectrometry identifies and quantifies specific peptides in a complex mixture with very high sensitivity and speed and thus has promise for the high throughput screening of clinical samples for candidate biomarkers. We have developed an interactive software platform, called MRMer, for managing highly complex MRM-MS experiments, including quantitative analyses using heavy/light isotopic peptide pairs. MRMer parses and extracts information from MS files encoded in the platform-independent mzXML data format. It extracts and infers precursor-product ion transition pairings, computes integrated ion intensities, and permits rapid visual curation for analyses exceeding 1000 precursor-product pairs. Results can be easily output for quantitative comparison of consecutive runs. Additionally MRMer incorporates features that permit the quantitative analysis experiments including heavy and light isotopic peptide pairs. MRMer is open source and provided under the Apache 2.0 license.

  19. A Collaborative Approach for Monitoring Nodes Behavior during Spectrum Sensing to Mitigate Multiple Attacks in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Mahmoud Khasawneh

    2017-01-01

    Full Text Available Spectrum sensing is the first step to overcome the spectrum scarcity problem in Cognitive Radio Networks (CRNs wherein all unutilized subbands in the radio environment are explored for better spectrum utilization. Adversary nodes can threaten these spectrum sensing results by launching passive and active attacks that prevent legitimate nodes from using the spectrum efficiently. Securing the spectrum sensing process has become an important issue in CRNs in order to ensure reliable and secure spectrum sensing and fair management of resources. In this paper, a novel collaborative approach during spectrum sensing process is proposed. It monitors the behavior of sensing nodes and identifies the malicious and misbehaving sensing nodes. The proposed approach measures the node’s sensing reliability using a value called belief level. All the sensing nodes are grouped into a specific number of clusters. In each cluster, a sensing node is selected as a cluster head that is responsible for collecting sensing-reputation reports from different cognitive nodes about each node in the same cluster. The cluster head analyzes information to monitor and judge the nodes’ behavior. By simulating the proposed approach, we showed its importance and its efficiency for achieving better spectrum security by mitigating multiple passive and active attacks.

  20. A Multiplexed Assay That Monitors Effects of Multiple Compound Treatment Times Reveals Candidate Immune-Enhancing Compounds.

    Science.gov (United States)

    Zhao, Ziyan; Henowitz, Liza; Zweifach, Adam

    2018-05-01

    We previously developed a flow cytometry assay that monitored lytic granule exocytosis in cytotoxic T lymphocytes stimulated by contacting beads coated with activating anti-CD3 antibodies. That assay was multiplexed in that responses of cells that did or did not receive the activating stimulus were distinguished via changes in light scatter accompanying binding of cells to beads, allowing us to discriminate compounds that activate responses on their own from compounds that enhance responses in cells that received the activating stimulus, all within a single sample. Here we add a second dimension of multiplexing by developing means to assess in a single sample the effects of treating cells with test compounds for different times. Bar-coding cells before adding them to test wells lets us determine compound treatment time while also monitoring activation status and response amplitude at the point of interrogation. This multiplexed assay is suitable for screening 96-well plates. We used it to screen compounds from the National Cancer Institute, identifying several compounds that enhance anti-LAMP1 responses. Multiple-treatment-time (MTT) screening enabled by bar-coding and read via high-throughput flow cytometry may be a generally useful method for facilitating the discovery of compounds of interest.

  1. A spreadsheet template compatible with Microsoft Excel and iWork Numbers that returns the simultaneous confidence intervals for all pairwise differences between multiple sample means.

    Science.gov (United States)

    Brown, Angus M

    2010-04-01

    The objective of the method described in this paper is to develop a spreadsheet template for the purpose of comparing multiple sample means. An initial analysis of variance (ANOVA) test on the data returns F--the test statistic. If F is larger than the critical F value drawn from the F distribution at the appropriate degrees of freedom, convention dictates rejection of the null hypothesis and allows subsequent multiple comparison testing to determine where the inequalities between the sample means lie. A variety of multiple comparison methods are described that return the 95% confidence intervals for differences between means using an inclusive pairwise comparison of the sample means. 2009 Elsevier Ireland Ltd. All rights reserved.

  2. Monitoring forest cover loss using multiple data streams, a case study of a tropical dry forest in Bolivia

    Science.gov (United States)

    Dutrieux, Loïc Paul; Verbesselt, Jan; Kooistra, Lammert; Herold, Martin

    2015-09-01

    Automatically detecting forest disturbances as they occur can be extremely challenging for certain types of environments, particularly those presenting strong natural variations. Here, we use a generic structural break detection framework (BFAST) to improve the monitoring of forest cover loss by combining multiple data streams. Forest change monitoring is performed using Landsat data in combination with MODIS or rainfall data to further improve the modelling and monitoring. We tested the use of the Normalized Difference Vegetation Index (NDVI) from the Moderate Resolution Imaging Spectroradiometer (MODIS) with varying spatial aggregation window sizes as well as a rainfall derived index as external regressors. The method was evaluated on a dry tropical forest area in lowland Bolivia where forest cover loss is known to occur, and we validated the results against a set of ground truth samples manually interpreted using the TimeSync environment. We found that the addition of an external regressor allows to take advantage of the difference in spatial extent between human induced and naturally induced variations and only detect the processes of interest. Of all configurations, we found the 13 by 13 km MODIS NDVI window to be the most successful, with an overall accuracy of 87%. Compared with a single pixel approach, the proposed method produced better time-series model fits resulting in increases of overall accuracy (from 82% to 87%), and decrease in omission and commission errors (from 33% to 24% and from 3% to 0% respectively). The presented approach seems particularly relevant for areas with high inter-annual natural variability, such as forests regularly experiencing exceptional drought events.

  3. Classifying Multiple Types of Hand Motions Using Electrocorticography During Intraoperative Awake Craniotomy & Seizure Monitoring Processes - Case Studies

    Directory of Open Access Journals (Sweden)

    Tao eXie

    2015-10-01

    Full Text Available In this work, some case studies were conducted toclassify several kinds of hand motions from electrocorticography(ECoG signals during intraoperative awake craniotomy &extraoperative seizure monitoring processes. Four subjects (P1,P2 with intractable epilepsy during seizure monitoring and P3,P4 with brain tumor during awake craniotomy participatedin the experiments. Subjects performed three types of handmotions (Grasp, Thumb-finger motion and Index-finger motioncontralateral to the motor cortex covered with ECoG electrodes.Two methods were used for signal processing. Method I:autoregressive (AR model with burg method was applied toextract features, and additional waveform length (WL featurehas been considered, finally the linear discriminative analysis(LDA was used as the classifier. Method II: stationary subspaceanalysis (SSA was applied for data preprocessing, and thecommon spatial pattern (CSP was used for feature extractionbefore LDA decoding process. Applying method I, the threeclassaccuracy of P1□P4 were 90.17%, 96.00%, 91.77% and92.95% respectively. For method II, the three-class accuracy ofP1□P4 were 72.00%, 93.17%, 95.22% and 90.36% respectively.This study verified the possibility of decoding multiple handmotion types during an awake craniotomy, which is the firststep towards dexterous neuroprosthetic control during surgicalimplantation, in order to verify the optimal placement of electrodes.The accuracy during awake craniotomy was comparableto results during seizure monitoring. This study also indicatedthat ECoG was a promising approach for precise identificationof eloquent cortex during awake craniotomy, and might forma promising BCI system that could benefit both patients andneurosurgeons.

  4. Classifying multiple types of hand motions using electrocorticography during intraoperative awake craniotomy and seizure monitoring processes—case studies

    Science.gov (United States)

    Xie, Tao; Zhang, Dingguo; Wu, Zehan; Chen, Liang; Zhu, Xiangyang

    2015-01-01

    In this work, some case studies were conducted to classify several kinds of hand motions from electrocorticography (ECoG) signals during intraoperative awake craniotomy & extraoperative seizure monitoring processes. Four subjects (P1, P2 with intractable epilepsy during seizure monitoring and P3, P4 with brain tumor during awake craniotomy) participated in the experiments. Subjects performed three types of hand motions (Grasp, Thumb-finger motion and Index-finger motion) contralateral to the motor cortex covered with ECoG electrodes. Two methods were used for signal processing. Method I: autoregressive (AR) model with burg method was applied to extract features, and additional waveform length (WL) feature has been considered, finally the linear discriminative analysis (LDA) was used as the classifier. Method II: stationary subspace analysis (SSA) was applied for data preprocessing, and the common spatial pattern (CSP) was used for feature extraction before LDA decoding process. Applying method I, the three-class accuracy of P1~P4 were 90.17, 96.00, 91.77, and 92.95% respectively. For method II, the three-class accuracy of P1~P4 were 72.00, 93.17, 95.22, and 90.36% respectively. This study verified the possibility of decoding multiple hand motion types during an awake craniotomy, which is the first step toward dexterous neuroprosthetic control during surgical implantation, in order to verify the optimal placement of electrodes. The accuracy during awake craniotomy was comparable to results during seizure monitoring. This study also indicated that ECoG was a promising approach for precise identification of eloquent cortex during awake craniotomy, and might form a promising BCI system that could benefit both patients and neurosurgeons. PMID:26483627

  5. Simultaneous occurrence of a supra- and an infratentorial glioma in a patient with Ollier's disease : more evidence for non-mesodermal tumor predisposition in multiple enchondromatosis

    NARCIS (Netherlands)

    Heeg, M; Klein, JP; Krikke, AP

    1998-01-01

    A case is presented in which two neuro-ectodermal tumors, an infra- and a supratentorial glioma, developed in a young man with multiple enchondromatosis of Ollier's disease. This is the third such case of multifocal low-grade glioma in Ollier's disease, suggesting a predisposition for non-mesodermal

  6. Simultaneous presence of endogenous retrovirus and herpes virus antigens has profound effect on cell-mediated immune responses: implications for multiple sclerosis

    DEFF Research Database (Denmark)

    Brudek, T.; Christensen, T.; Hansen, H.J.

    2004-01-01

    Retroviruses have been suggested as possible pathogenic factors in multiple sclerosis (MS), supported by the observation that endogenous retroviruses are activated in MS patients. Different members of the herpes family of which several are neurotropic have also been suggested as factors in MS pat...

  7. Simplified response monitoring criteria for multiple myeloma in patients undergoing therapy with novel agents using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, Christoph; Horger, Marius; Kum, Sara [Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany); Weisel, Katja [Department of Internal Medicine II – Hematology & Oncology, Eberhard-Karls-University Tuebingen, Otfried-Müller-Str. 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, 600 N Wolfe St., Baltimore, MD 21287 (United States); Ioanoviciu, Sorin D. [Department of Internal Medicine, Clinical Municipal Hospital Timisoara, Gheorghe Dima Str. 5, 300079 Timisoara (Romania); Bier, Georg, E-mail: georg.bier@med.uni-tuebingen.de [Department of Neuroradiology, Eberhard-Karls-University Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)

    2016-12-15

    Highlights: • A simplified method for response monitoring of multiple myeloma is proposed. • Medullary bone lesions of all limbs were included and analysed. • Diameters of ≥2 medullary bone lesions are sufficient for therapy monitoring. - Abstract: Introduction: Multiple myeloma is a malignant hematological disorder of the mature B-cell lymphocytes originating in the bone marrow. While therapy monitoring is still mainly based on laboratory biomarkers, the additional use of imaging has been advocated due to inaccuracies of serological biomarkers or in a-secretory myelomas. Non-enhanced CT and MRI have similar sensitivities for lesions in yellow marrow-rich bone marrow cavities with a favourable risk and cost-effectiveness profile of CT. Nevertheless, these methods are still limited by frequently high numbers of medullary lesions and its time consumption for proper evaluation. Objective: To establish simplified response criteria by correlating size and CT attenuation changes of medullary multiple myeloma lesions in the appendicular skeleton with the course of lytic bone lesions in the entire skeleton. Furthermore to evaluate these criteria with respect to established hematological myeloma-specific parameters for the prediction of treatment response to bortezomib or lenalidomide. Materials and methods: Non-enhanced reduced-dose whole-body CT examinations of 78 consecutive patients (43 male, 35 female, mean age 63.69 ± 9.2 years) with stage III multiple myeloma were retrospectively re-evaluated. On per patient basis, size and mean CT attenuation of 2–4 representative lesions in the limbs were measured at baseline and at a follow-up after a mean of 8 months. Results were compared with the course of lytical bone lesions as well with that of specific hematological biomarkers. Myeloma response was assessed according to the International Myeloma Working Group (IMWG) uniform response criteria. Testing for correlation between response of medullary lesions (Resp

  8. Circumvention of Mcl-1-dependent drug resistance by simultaneous Chk1 and MEK1/2 inhibition in human multiple myeloma cells.

    Science.gov (United States)

    Pei, Xin-Yan; Dai, Yun; Felthousen, Jessica; Chen, Shuang; Takabatake, Yukie; Zhou, Liang; Youssefian, Leena E; Sanderson, Michael W; Bodie, Wesley W; Kramer, Lora B; Orlowski, Robert Z; Grant, Steven

    2014-01-01

    The anti-apoptotic protein Mcl-1 plays a major role in multiple myeloma (MM) cell survival as well as bortezomib- and microenvironmental forms of drug resistance in this disease. Consequently, there is a critical need for strategies capable of targeting Mcl-1-dependent drug resistance in MM. The present results indicate that a regimen combining Chk1 with MEK1/2 inhibitors effectively kills cells displaying multiple forms of drug resistance stemming from Mcl-1 up-regulation in association with direct transcriptional Mcl-1 down-regulation and indirect disabling of Mcl-1 anti-apoptotic function through Bim up-regulation and increased Bim/Mcl-1 binding. These actions release Bak from Mcl-1, accompanied by Bak/Bax activation. Analogous events were observed in both drug-naïve and acquired bortezomib-resistant MM cells displaying increased Mcl-1 but diminished Bim expression, or cells ectopically expressing Mcl-1. Moreover, concomitant Chk1 and MEK1/2 inhibition blocked Mcl-1 up-regulation induced by IL-6/IGF-1 or co-culture with stromal cells, effectively overcoming microenvironment-related drug resistance. Finally, this regimen down-regulated Mcl-1 and robustly killed primary CD138+ MM cells, but not normal hematopoietic cells. Together, these findings provide novel evidence that this targeted combination strategy could be effective in the setting of multiple forms of Mcl-1-related drug resistance in MM.

  9. Circumvention of Mcl-1-dependent drug resistance by simultaneous Chk1 and MEK1/2 inhibition in human multiple myeloma cells.

    Directory of Open Access Journals (Sweden)

    Xin-Yan Pei

    Full Text Available The anti-apoptotic protein Mcl-1 plays a major role in multiple myeloma (MM cell survival as well as bortezomib- and microenvironmental forms of drug resistance in this disease. Consequently, there is a critical need for strategies capable of targeting Mcl-1-dependent drug resistance in MM. The present results indicate that a regimen combining Chk1 with MEK1/2 inhibitors effectively kills cells displaying multiple forms of drug resistance stemming from Mcl-1 up-regulation in association with direct transcriptional Mcl-1 down-regulation and indirect disabling of Mcl-1 anti-apoptotic function through Bim up-regulation and increased Bim/Mcl-1 binding. These actions release Bak from Mcl-1, accompanied by Bak/Bax activation. Analogous events were observed in both drug-naïve and acquired bortezomib-resistant MM cells displaying increased Mcl-1 but diminished Bim expression, or cells ectopically expressing Mcl-1. Moreover, concomitant Chk1 and MEK1/2 inhibition blocked Mcl-1 up-regulation induced by IL-6/IGF-1 or co-culture with stromal cells, effectively overcoming microenvironment-related drug resistance. Finally, this regimen down-regulated Mcl-1 and robustly killed primary CD138+ MM cells, but not normal hematopoietic cells. Together, these findings provide novel evidence that this targeted combination strategy could be effective in the setting of multiple forms of Mcl-1-related drug resistance in MM.

  10. Monitoring of multiple solvent induced form changes during high shear wet granulation and drying processes using online Raman spectroscopy.

    Science.gov (United States)

    Reddy, Jay Poorna; Jones, John W; Wray, Patrick S; Dennis, Andrew B; Brown, Jonathan; Timmins, Peter

    2018-04-25

    simultaneously monitor the three forms in real time during wet granulation and drying using online Raman spectroscopy. The results regarding the effect of process parameters on the degree of transformation are critical for designing a robust process that ensures a consistent form in the final drug product. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. A novel usage of hydrogen treatment to improve the indium incorporation and internal quantum efficiency of green InGaN/GaN multiple quantum wells simultaneously

    International Nuclear Information System (INIS)

    Ren, Peng; Zhang, Ning; Xue, Bin; Liu, Zhe; Wang, Junxi; Li, Jinmin

    2016-01-01

    The challenge for improving the internal quantum efficiency (IQE) of InGaN-based light emitting diodes (LED) in the green light range is referred to as the ‘green gap’. However the IQE of InGaN-based LEDs often drops when the emission peak wavelength is adjusted through reducing the growth temperature. Although hydrogen (H 2 ) can improve surface morphology, it reduces the indium incorporation significantly. Here, a novel usage of H 2 treatment on the GaN barrier before the InGaN quantum well is demonstrated to enhance indium incorporation efficiency and improve the IQE simultaneously for the first time. The mechanism behind it is systematically investigated and explained in detail. The possible reason for this phenomenon is the strain relieving function by the undulant GaN barrier surface after H 2 treatment. Test measurements show that applying 0.2 min H 2 treatment on the barrier would reduce defects and enhance indium incorporation, which would improve the localization effect and finally lead to a higher IQE. Although further increasing the treatment time to 0.4 min incorporates more indium atoms, the IQE decreases at the expense of more defects and a larger polarization field than the 0.2 min sample. (paper)

  12. Multiple Constraints Based Robust Matching of Poor-Texture Close-Range Images for Monitoring a Simulated Landslide

    Directory of Open Access Journals (Sweden)

    Gang Qiao

    2016-05-01

    Full Text Available Landslides are one of the most destructive geo-hazards that can bring about great threats to both human lives and infrastructures. Landslide monitoring has been always a research hotspot. In particular, landslide simulation experimentation is an effective tool in landslide research to obtain critical parameters that help understand the mechanism and evaluate the triggering and controlling factors of slope failure. Compared with other traditional geotechnical monitoring approaches, the close-range photogrammetry technique shows potential in tracking and recording the 3D surface deformation and failure processes. In such cases, image matching usually plays a critical role in stereo image processing for the 3D geometric reconstruction. However, the complex imaging conditions such as rainfall, mass movement, illumination, and ponding will reduce the texture quality of the stereo images, bringing about difficulties in the image matching process and resulting in very sparse matches. To address this problem, this paper presents a multiple-constraints based robust image matching approach for poor-texture close-range images particularly useful in monitoring a simulated landslide. The Scale Invariant Feature Transform (SIFT algorithm was first applied to the stereo images for generation of scale-invariate feature points, followed by a two-step matching process: feature-based image matching and area-based image matching. In the first feature-based matching step, the triangulation process was performed based on the SIFT matches filtered by the Fundamental Matrix (FM and a robust checking procedure, to serve as the basic constraints for feature-based iterated matching of all the non-matched SIFT-derived feature points inside each triangle. In the following area-based image-matching step, the corresponding points of the non-matched features in each triangle of the master image were predicted in the homologous triangle of the searching image by using geometric

  13. Structural health monitoring and damage assessment using measured FRFs from multiple sensors. Part II. Decision making with RBF networks

    Energy Technology Data Exchange (ETDEWEB)

    Zang, C.; Friswell, M.I. [Dept. of Aerospace Engineering, Univ. of Bristol, Bristol (United Kingdom); Imregun, M. [Dept. of Mechanical Engineering, Imperial Coll., London (United Kingdom)

    2003-07-01

    This paper is the second of two papers concerned with structural health monitoring and damage assessment using measured FRFs from multiple sensors, and discusses the decision making technique with radial basis function (RBF) neural networks. In PART 1 of the paper, the correlation criteria showed their capability to indicate various changes to the structure's state. PART 2, presented here, develops the methodology of decision theory to identify precisely all of the structure states. Although, the statistical approach can be used for classification, interpreting the information is difficult. Neural network techniques have been proven to possess many advantages for classification due to their learning ability and good generalization. In this paper, the radial basis function neural network is applied for function approximation and recognition. The key idea is to partition the input space (the indicators of the correlation criteria) into a number of subspaces that are in the form of hyper spheres. Then, the widely used k-mean clustering algorithm was selected as a logical approach to detecting the structure states. A bookshelf structure with measured frequency responses from 24 accelerometers was used to demonstrate the effectiveness of the method. The results show the successful classification of all structure states, for instance, the undamaged and damage states, damage locations and damage levels, and the environmental variability. (orig.)

  14. Automatic identification approach for high-performance liquid chromatography-multiple reaction monitoring fatty acid global profiling.

    Science.gov (United States)

    Tie, Cai; Hu, Ting; Jia, Zhi-Xin; Zhang, Jin-Lan

    2015-08-18

    Fatty acids (FAs) are a group of lipid molecules that are essential to organisms. As potential biomarkers for different diseases, FAs have attracted increasing attention from both biological researchers and the pharmaceutical industry. A sensitive and accurate method for globally profiling and identifying FAs is required for biomarker discovery. The high selectivity and sensitivity of high-performance liquid chromatography-multiple reaction monitoring (HPLC-MRM) gives it great potential to fulfill the need to identify FAs from complicated matrices. This paper developed a new approach for global FA profiling and identification for HPLC-MRM FA data mining. Mathematical models for identifying FAs were simulated using the isotope-induced retention time (RT) shift (IRS) and peak area ratios between parallel isotope peaks for a series of FA standards. The FA structures were predicated using another model based on the RT and molecular weight. Fully automated FA identification software was coded using the Qt platform based on these mathematical models. Different samples were used to verify the software. A high identification efficiency (greater than 75%) was observed when 96 FA species were identified in plasma. This FAs identification strategy promises to accelerate FA research and applications.

  15. Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest.

    Science.gov (United States)

    Sun, Liangliang; Li, Yihan; Champion, Matthew M; Zhu, Guijie; Wojcik, Roza; Dovichi, Norman J

    2013-06-07

    Capillary zone electrophoresis-multiple/single reaction monitoring (CZE-MRM/SRM), which employed an electrokinetically driven sheath-flow electrospray interface, was used for the rapid and highly sensitive detection of protein analytes in complex tryptic digests. MRM channels were developed against a commercial exponential mixture of bovine proteins. Five proteins spanning four orders of magnitude concentration range were confidently detected from only 2.5 ng of the digest mixture; the mass detection limits (S/N = 3) of two detected proteins, alpha-casein and glutamate dehydrogenase were about 600 zmol and 30 amol, respectively. This technique was then applied to a RAW 264.7 cell lysate digest. Three proteins were confidently and reproducibly detected from 100 pg of this digest. The sample amount corresponds to the approximate protein content from a single cell, which suggests that CZE-MRM may be a useful analytical tool in chemical cytometry. In addition to providing highly sensitive detection of proteins in complex mixtures, this system is highly rapid; migration time of the protein digests was less than 10 min.

  16. Comparison of pharmacokinetic behavior of two iridoid glycosides in rat plasma after oral administration of crude Cornus officinals and its jiuzhipin by high performance liquid chromatography triple quadrupole mass spectrometry combined with multiple reactions monitoring mode

    Science.gov (United States)

    Chen, Xiaocheng; Cao, Gang; Jiang, Jianping

    2014-01-01

    Objective: The present study examined the pharmacokinetic profiles of two iridoid glycosides named morroniside and loganin in rat plasma after oral administration of crude and processed Cornus officinals. Materials and Methods: A rapid, selective and specific high-performance liquid chromatography/electrospray ionization tandem mass spectrometry with multiple reactions monitoring mode was developed to simultaneously investigate the pharmacokinetic profiles of morroniside and loganin in rat plasma after oral administration of crude C. officinals and its jiuzhipin. Results: The morroniside and loganin in crude and processed C. officinals could be simultaneously determined within 7.4 min. Linear calibration curves were obtained over the concentration ranges of 45.45-4800 ng/mL for all the analytes. The intra-and inter-day precisions relative standard deviation was lesser than 2.84% and 4.12%, respectively. Conclusion: The pharmacokinetic parameters of two iridoid glucosides were also compared systematically between crude and processed C. officinals. This paper provides the theoretical proofs for further explaining the processing mechanism of Traditional Chinese Medicines. PMID:24914290

  17. Serological monitoring of previously treated lepromatous patients during a course of multiple immunotherapy treatments with heat-killed Mycobacterium leprae and BCG

    NARCIS (Netherlands)

    Douglas, J. T.; Hirsch, D. S.; Fajardo, T. T.; Guido, L. S.; Klatser, P. R.

    1990-01-01

    Two-hundred and seventy lepromatous patients who had completed treatment received multiple treatments with heat-killed M. leprae and BCG and were monitored for changes in humoral responses to M. leprae-specific antigens. These patients were divided into four treatment groups: placebo (n = 69); BCG

  18. Optimal design of monitoring networks for multiple groundwater quality parameters using a Kalman filter: application to the Irapuato-Valle aquifer.

    Science.gov (United States)

    Júnez-Ferreira, H E; Herrera, G S; González-Hita, L; Cardona, A; Mora-Rodríguez, J

    2016-01-01

    A new method for the optimal design of groundwater quality monitoring networks is introduced in this paper. Various indicator parameters were considered simultaneously and tested for the Irapuato-Valle aquifer in Mexico. The steps followed in the design were (1) establishment of the monitoring network objectives, (2) definition of a groundwater quality conceptual model for the study area, (3) selection of the parameters to be sampled, and (4) selection of a monitoring network by choosing the well positions that minimize the estimate error variance of the selected indicator parameters. Equal weight for each parameter was given to most of the aquifer positions and a higher weight to priority zones. The objective for the monitoring network in the specific application was to obtain a general reconnaissance of the water quality, including water types, water origin, and first indications of contamination. Water quality indicator parameters were chosen in accordance with this objective, and for the selection of the optimal monitoring sites, it was sought to obtain a low-uncertainty estimate of these parameters for the entire aquifer and with more certainty in priority zones. The optimal monitoring network was selected using a combination of geostatistical methods, a Kalman filter and a heuristic optimization method. Results show that when monitoring the 69 locations with higher priority order (the optimal monitoring network), the joint average standard error in the study area for all the groundwater quality parameters was approximately 90 % of the obtained with the 140 available sampling locations (the set of pilot wells). This demonstrates that an optimal design can help to reduce monitoring costs, by avoiding redundancy in data acquisition.

  19. EPR spectroscopy of MRI-related Gd(III) complexes: simultaneous analysis of multiple frequency and temperature spectra, including static and transient crystal field effects.

    Science.gov (United States)

    Rast, S; Borel, A; Helm, L; Belorizky, E; Fries, P H; Merbach, A E

    2001-03-21

    For the first time, a very general theoretical method is proposed to interpret the full electron paramagnetic resonance (EPR) spectra at multiple temperatures and frequencies in the important case of S-state metal ions complexed in liquid solution. This method is illustrated by a careful analysis of the measured spectra of two Gd3+ (S = 7/2) complexes. It is shown that the electronic relaxation mechanisms at the origin of the EPR line shape arise from the combined effects of the modulation of the static crystal field by the random Brownian rotation of the complex and of the transient zero-field splitting. A detailed study of the static crystal field mechanism shows that, contrarily to the usual global models involving only second-order terms, the fourth and sixth order terms can play a non-negligible role. The obtained parameters are well interpreted in the framework of the physics of the various underlying relaxation processes. A better understanding of these mechanisms is highly valuable since they partly control the efficiency of paramagnetic metal ions in contrast agents for medical magnetic resonance imaging (MRI).

  20. Simultaneous regression of Philadelphia chromosome and multiple nonrecurrent clonal chromosomal abnormalities with imatinib mesylate in a patient autografted 22 years before for chronic myelogenous leukemia.

    Science.gov (United States)

    Van Den Akker, J; Coppo, P; Portnoï, M F; Barbu, V; Bories, D; Gorin, N C

    2007-09-01

    A 31-year-old patient developed chronic myelogenous leukemia (CML) in November, 1983. In November 1984, following a diagnosis of acceleration, he received an autologous hemopoietic transplant after conditioning with cyclophosphamide and total body irradiation. The autologous marrow was purged with mafosfamide. Over 20 years, the patient remained in chronic phase of CML. Multiple nonrecurrent clonal chromosomal abnormalities appeared leading to a very complex karyotype, including among others involvement of chromosomes 1, 7, 9, 13, 19, and X. Fluorescent in situ hybridization showed that the two chromosomes 9 were involved. Acute myeloid crisis was diagnosed in February, 2004. Treatment with imatinib mesylate resulted within 6 months in a total disappearance of all chromosomal abnormalities with a complete cytogenetic and molecular response, which persists 3 years later. We question whether the ex vivo purging procedure with mafosfamide has favored the occurrence of these particular cytogenetic abnormalities (with no independent oncogenic potential) within the original leukemic stem cell pool. It remains unclear whether the autologous transplantation has indeed resulted into some prolongation of the duration of the chronic phase, which lasted for 20 years. At time of acute crisis, the dramatic response to imatinib mesylate leading to a complete cytogenetic and molecular response is noteworthy.

  1. Development of protein biomarkers in cerebrospinal fluid for secondary progressive multiple sclerosis using selected reaction monitoring mass spectrometry (SRM-MS

    Directory of Open Access Journals (Sweden)

    Jia Yan

    2012-07-01

    Full Text Available Abstract Background Multiple sclerosis (MS is a chronic inflammatory disorder of the central nervous system (CNS. It involves damage to the myelin sheath surrounding axons and to the axons themselves. MS most often presents with a series of relapses and remissions but then evolves over a variable period of time into a slowly progressive form of neurological dysfunction termed secondary progressive MS (SPMS. The reasons for this change in clinical presentation are unclear. The absence of a diagnostic marker means that there is a lag time of several years before the diagnosis of SPMS can be established. At the same time, understanding the mechanisms that underlie SPMS is critical to the development of rational therapies for this untreatable stage of the disease. Results Using high performance liquid chromatography-coupled mass spectrometry (HPLC; we have established a highly specific and sensitive selected reaction monitoring (SRM assay. Our multiplexed SRM assay has facilitated the simultaneous detection of surrogate peptides originating from 26 proteins present in cerebrospinal fluid (CSF. Protein levels in CSF were generally ~200-fold lower than that in human sera. A limit of detection (LOD was determined to be as low as one femtomol. We processed and analysed CSF samples from a total of 22 patients with SPMS, 7 patients with SPMS treated with lamotrigine, 12 patients with non-inflammatory neurological disorders (NIND and 10 healthy controls (HC for the levels of these 26 selected potential protein biomarkers. Our SRM data found one protein showing significant difference between SPMS and HC, three proteins differing between SPMS and NIND, two proteins between NIND and HC, and 11 protein biomarkers showing significant difference between a lamotrigine-treated and untreated SPMS group. Principal component analysis (PCA revealed that these 26 proteins were correlated, and could be represented by four principal components. Overall, we established an

  2. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Horger, M.; Thaiss, W.M.; Fritz, J.; Ditt, H.; Weisel, K.; Haap, M.; Kloth, Christopher

    2018-01-01

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ( WB MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p < 0.001). Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p < 0.001*) and significant decrease of minimal bone (p < 0.002*) in the SD/PR/VGPR/CR group. Qualitative MRI showed PD in 14/47 (29.7%) and SD/PR/VGPR/CR in 33/47 (70.3%). Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p < 0.001*). Imaging response monitoring using MRI is superior to CT only if qualitative parameters are used, whereas there was no

  3. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Horger, M.; Thaiss, W.M. [Eberhard-Karls-University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Fritz, J. [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Ditt, H. [Siemens AG Healthcare, Sector Imaging and Interventional Radiology, Forchheim (Germany); Weisel, K. [Eberhard-Karls-University Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Haap, M. [Eberhard-Karls-University Tuebingen, Department of Internal Medicine IV, Tuebingen, (Germany); Kloth, Christopher [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2018-03-15

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ({sub WB}MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p < 0.001). Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p < 0.001*) and significant decrease of minimal bone (p < 0.002*) in the SD/PR/VGPR/CR group. Qualitative MRI showed PD in 14/47 (29.7%) and SD/PR/VGPR/CR in 33/47 (70.3%). Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p < 0.001*). Imaging response monitoring using MRI is superior to CT only if qualitative parameters are used, whereas there was

  4. Errors Recruit both Cognitive and Emotional Monitoring Systems: Simultaneous Intracranial Recordings in the Dorsal Anterior Cingulate Gyrus and Amygdala Combined with fMRI

    Science.gov (United States)

    Pourtois, Gilles; Vocat, Roland; N'Diaye, Karim; Spinelli, Laurent; Seeck, Margitta; Vuilleumier, Patrik

    2010-01-01

    We studied error monitoring in a human patient with unique implantation of depth electrodes in both the left dorsal cingulate gyrus and medial temporal lobe prior to surgery. The patient performed a speeded go/nogo task and made a substantial number of commission errors (false alarms). As predicted, intracranial Local Field Potentials (iLFPs) in…

  5. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    Science.gov (United States)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  6. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma.

    Science.gov (United States)

    Horger, M; Fritz, J; Thaiss, W M; Ditt, H; Weisel, K; Haap, M; Kloth, Christopher

    2018-03-01

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ( WB MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p quantitative parameters with either CT or MRI.

  7. Acyl chains of phospholipase D transphosphatidylation products in Arabidopsis cells: a study using multiple reaction monitoring mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Dominique Rainteau

    Full Text Available BACKGROUND: Phospholipases D (PLD are major components of signalling pathways in plant responses to some stresses and hormones. The product of PLD activity is phosphatidic acid (PA. PAs with different acyl chains do not have the same protein targets, so to understand the signalling role of PLD it is essential to analyze the composition of its PA products in the presence and absence of an elicitor. METHODOLOGY/PRINCIPAL FINDINGS: Potential PLD substrates and products were studied in Arabidopsis thaliana suspension cells treated with or without the hormone salicylic acid (SA. As PA can be produced by enzymes other than PLD, we analyzed phosphatidylbutanol (PBut, which is specifically produced by PLD in the presence of n-butanol. The acyl chain compositions of PBut and the major glycerophospholipids were determined by multiple reaction monitoring (MRM mass spectrometry. PBut profiles of untreated cells or cells treated with SA show an over-representation of 160/18:2- and 16:0/18:3-species compared to those of phosphatidylcholine and phosphatidylethanolamine either from bulk lipid extracts or from purified membrane fractions. When microsomal PLDs were used in in vitro assays, the resulting PBut profile matched exactly that of the substrate provided. Therefore there is a mismatch between the acyl chain compositions of putative substrates and the in vivo products of PLDs that is unlikely to reflect any selectivity of PLDs for the acyl chains of substrates. CONCLUSIONS: MRM mass spectrometry is a reliable technique to analyze PLD products. Our results suggest that PLD action in response to SA is not due to the production of a stress-specific molecular species, but that the level of PLD products per se is important. The over-representation of 160/18:2- and 16:0/18:3-species in PLD products when compared to putative substrates might be related to a regulatory role of the heterogeneous distribution of glycerophospholipids in membrane sub-domains.

  8. Accurate quantification of 5 German cockroach (GCr) allergens in complex extracts using multiple reaction monitoring mass spectrometry (MRM MS).

    Science.gov (United States)

    Mindaye, S T; Spiric, J; David, N A; Rabin, R L; Slater, J E

    2017-12-01

    German cockroach (GCr) allergen extracts are complex and heterogeneous products, and methods to better assess their potency and composition are needed for adequate studies of their safety and efficacy. The objective of this study was to develop an assay based on liquid chromatography and multiple reaction monitoring mass spectrometry (LC-MRM MS) for rapid, accurate, and reproducible quantification of 5 allergens (Bla g 1, Bla g 2, Bla g 3, Bla g 4, and Bla g 5) in crude GCr allergen extracts. We first established a comprehensive peptide library of allergens from various commercial extracts as well as recombinant allergens. Peptide mapping was performed using high-resolution MS, and the peptide library was then used to identify prototypic and quantotypic peptides to proceed with MRM method development. Assay development included a systematic optimization of digestion conditions (buffer, digestion time, and trypsin concentration), chromatographic separation, and MS parameters. Robustness and suitability were assessed following ICH (Q2 [R1]) guidelines. The method is precise (RSD  0.99, 0.01-1384 fmol/μL), and sensitive (LLOD and LLOQ MS, we quantified allergens from various commercial GCr extracts and showed considerable variability that may impact clinical efficacy. Our data demonstrate that the LC-MRM MS method is valuable for absolute quantification of allergens in GCr extracts and likely has broader applicability to other complex allergen extracts. Definitive quantification provides a new standard for labelling of allergen extracts, which will inform patient care, enable personalized therapy, and enhance the efficacy of immunotherapy for environmental and food allergies. © 2017 The Authors. Clinical & Experimental Allergy published by John Wiley & Sons Ltd. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  9. Batch and Continuous Flow Preparation of Hantzsch 1,4-Dihydropyridines under Microwave Heating and Simultaneous Real-time Monitoring by Raman Spectroscopy. An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Sylvain Christiaens

    2014-07-01

    Full Text Available Dialkyl 1,4-dihydro-2,6-dimethylpyridine-3,5-dicarboxylates have been prepared in a batch mode under conventional heating as well as under continuous flow conditions in the Miniflow 200SS, Sairem’s microwave-assisted batch and continuous flow equipment. Real-time monitoring of the reactions by Raman spectroscopy enabled to compare both heating modes and to determine (optimized reaction times.

  10. Wearable, Flexible, and Multifunctional Healthcare Device with an ISFET Chemical Sensor for Simultaneous Sweat pH and Skin Temperature Monitoring.

    Science.gov (United States)

    Nakata, Shogo; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu

    2017-03-24

    Real-time daily healthcare monitoring may increase the chances of predicting and diagnosing diseases in their early stages which, currently, occurs most frequently during medical check-ups. Next-generation noninvasive healthcare devices, such as flexible multifunctional sensor sheets designed to be worn on skin, are considered to be highly suitable candidates for continuous real-time health monitoring. For healthcare applications, acquiring data on the chemical state of the body, alongside physical characteristics such as body temperature and activity, are extremely important for predicting and identifying potential health conditions. To record these data, in this study, we developed a wearable, flexible sweat chemical sensor sheet for pH measurement, consisting of an ion-sensitive field-effect transistor (ISFET) integrated with a flexible temperature sensor: we intend to use this device as the foundation of a fully integrated, wearable healthcare patch in the future. After characterizing the performance, mechanical flexibility, and stability of the sensor, real-time measurements of sweat pH and skin temperature are successfully conducted through skin contact. This flexible integrated device has the potential to be developed into a chemical sensor for sweat for applications in healthcare and sports.

  11. No adverse effects detected for simultaneous whole-body exposure to multiple-frequency radiofrequency electromagnetic fields for rats in the intrauterine and pre- and post-weaning periods

    International Nuclear Information System (INIS)

    Shirai, Tomoyuki; Wang, Jianqing; Kawabe, Mayumi; Wake, Kanako; Watanabe, So-ichi; Takahashi, Satoru; Fujiwara, Osamu

    2017-01-01

    In everyday life, people are exposed to radiofrequency (RF) electromagnetic fields (EMFs) with multiple frequencies. To evaluate the possible adverse effects of multifrequency RF EMFs, we performed an experiment in which pregnant rats and their delivered offspring were simultaneously exposed to eight different communication signal EMFs (two of 800 MHz band, two of 2 GHz band, one of 2.4 GHz band, two of 2.5 GHz band and one of 5.2 GHz band). Thirty six pregnant Sprague-Dawley (SD) 10-week-old rats were divided into three groups of 12 rats: one control (sham exposure) group and two experimental (low- and high-level RF EMF exposure) groups. The whole body of the mother rats was exposed to the RF EMFs for 20 h per day from Gestational Day 7 to weaning, and F 1 offspring rats (46–48 F1 pups per group) were then exposed up to 6 weeks of age also for 20 h per day. The parameters evaluated included the growth, gestational condition and organ weights of the dams; the survival rates, development, growth, physical and functional development, memory function, and reproductive ability of the F 1 offspring; and the embryotoxicity and teratogenicity in the F 2 rats. No abnormal findings were observed in the dams or F 1 offspring exposed to the RF EMFs or to the F 2 offspring for any of the parameters evaluated. Thus, under the conditions of the present experiment, simultaneous whole-body exposure to eight different communication signal EMFs at frequencies between 800 MHz and 5.2 GHz did not show any adverse effects on pregnancy or on the development of rats.

  12. Multiple Primary Cancers: Simultaneously Occurring Prostate ...

    African Journals Online (AJOL)

    2016-05-20

    May 20, 2016 ... occurring prostate cancer and other primary tumors-our experience and literature ..... thyroid cancers, pancreatic tumors, renal cancers, and melanoma. ... Hsing AW, Yeboah E, Biritwum R, Tettey Y, De Marzo AM,. Adjei A, et ...

  13. Adaptive Arrays for Multiple Simultaneous Desired Signals.

    Science.gov (United States)

    1983-08-01

    weights [Equation (4)]. Using Equation (6), the inverse of the covariance matrix is given by 5 4 i *ŕm * T ". -1 1 I d Z dij (7) L -I + UT U* 4 di x di...Equations (11) and (12) p k = A k Ik d (14) dk aki*~~* ( ~ dk LJk Udk) and 1 t IjI II di l() 27 x = (1 + t UT U*) Thus, the output SNR of the kth desired...signals are assumed to be of the same frequency. There is no jammer 9 0 dB SIGNAL 10 dB SIGNAL 90 % 90 180 Fiur .dptdpatrnofalier rayo tn strpc lmet

  14. The Impacts of Multiple Simultaneous Climate Variations

    Science.gov (United States)

    2016-12-01

    in the ITCZ and SPCZ, and between the subtropical high and subpolar lows where the extratropical storm tracks occur. Lower PR values tend to occur...especially over and near the maritime continent and Amazon, in the ITCZ and SPCZ, and in the extratropical storm tracks over the North Pacific and...gradient and low tropospheric winds are strong (cf. Figure 9)—for example, between the subtropical highs and subpolar lows where the extratropical storm

  15. Simultaneous Detection of Multiple Disease States.

    Science.gov (United States)

    1990-02-14

    analytes to be assayed in a panel forma And due to its simplicity, OIA has been demonstrated to be generally applicable to a wide range of testing...into two distinct formats on the basis of signal generation: visual and instrumented. In both cases monocrystalline silicon wafers are employed as...Due to the limited surface area available on the monocrystalline silicon wafers, attention must be paid to efficient immobilization to ensure

  16. Multiple primary cancers: Simultaneously occurring prostate cancer ...

    African Journals Online (AJOL)

    We also reviewed the existing literatures for possible biologic links between prostatic carcinoma and other primary tumors. ... The primary tumors co-existing with prostate cancer were colonic adenocarcinoma, rectal adenocarcinoma, urinary bladder transitional cell carcinoma, primary liver cell carcinoma, and thyroid ...

  17. Flight controller design of unmanned airplane for radiation monitoring system via structured robust controller design using multiple model approach. Radiation monitoring flight in Namie-machi in Fukushima prefecture

    International Nuclear Information System (INIS)

    Sato, Masayuki; Muraoka, Koji; Hozumi, Koki; Sanada, Yukihisa; Yamada, Tsutomu; Torii, Tatsuo

    2015-01-01

    Due to the tragic accident of radioactive contaminant spread from Fukushima Dai-ichi nuclear power plant, the necessity of unmanned systems for radiation monitoring has been increasing. This paper concerns the flight controller design of an unmanned airplane which has been developed for radiation monitoring around the power plant. The flight controller consists of conventional control elements, i.e. Stability/Control Augmentation System (S/CAS) with PI controllers and guidance loops with PID controllers. The gains in these controllers are designed by minimizing appropriately defined cost functions for several possible models and disturbances to produce structured robust flight controllers. (This method is called as 'multiple model approach'.) Control performance of our flight controller was evaluated through flight tests and a primitive flight of radiation monitoring in Namie-machi in Fukushima prefecture was conducted in Jan. 2014. Flight results are included in this paper. (author)

  18. Monitoring and identification of spatiotemporal landscape changes in multiple remote sensing images by using a stratified conditional Latin hypercube sampling approach and geostatistical simulation.

    Science.gov (United States)

    Lin, Yu-Pin; Chu, Hone-Jay; Huang, Yu-Long; Tang, Chia-Hsi; Rouhani, Shahrokh

    2011-06-01

    This study develops a stratified conditional Latin hypercube sampling (scLHS) approach for multiple, remotely sensed, normalized difference vegetation index (NDVI) images. The objective is to sample, monitor, and delineate spatiotemporal landscape changes, including spatial heterogeneity and variability, in a given area. The scLHS approach, which is based on the variance quadtree technique (VQT) and the conditional Latin hypercube sampling (cLHS) method, selects samples in order to delineate landscape changes from multiple NDVI images. The images are then mapped for calibration and validation by using sequential Gaussian simulation (SGS) with the scLHS selected samples. Spatial statistical results indicate that in terms of their statistical distribution, spatial distribution, and spatial variation, the statistics and variograms of the scLHS samples resemble those of multiple NDVI images more closely than those of cLHS and VQT samples. Moreover, the accuracy of simulated NDVI images based on SGS with scLHS samples is significantly better than that of simulated NDVI images based on SGS with cLHS samples and VQT samples, respectively. However, the proposed approach efficiently monitors the spatial characteristics of landscape changes, including the statistics, spatial variability, and heterogeneity of NDVI images. In addition, SGS with the scLHS samples effectively reproduces spatial patterns and landscape changes in multiple NDVI images.

  19. Fluorescent "on-off-on" switching sensor based on CdTe quantum dots coupled with multiwalled carbon nanotubes@graphene oxide nanoribbons for simultaneous monitoring of dual foreign DNAs in transgenic soybean.

    Science.gov (United States)

    Li, Yaqi; Sun, Li; Qian, Jing; Long, Lingliang; Li, Henan; Liu, Qian; Cai, Jianrong; Wang, Kun

    2017-06-15

    With the increasing concern of potential health and environmental risk, it is essential to develop reliable methods for transgenic soybean detection. Herein, a simple, sensitive and selective assay was constructed based on homogeneous fluorescence resonance energy transfer (FRET) between CdTe quantum dots (QDs) and multiwalled carbon nanotubes@graphene oxide nanoribbons (MWCNTs@GONRs) to form the fluorescent "on-off-on" switching for simultaneous monitoring dual target DNAs of promoter cauliflower mosaic virus 35s (P35s) and terminator nopaline synthase (TNOS) from transgenic soybean. The capture DNAs were immobilized with corresponding QDs to obtain strong fluorescent signals (turning on). The strong π-π stacking interaction between single-stranded DNA (ssDNA) probes and MWCNTs@GONRs led to minimal background fluorescence due to the FRET process (turning off). The targets of P35s and TNOS were recognized by dual fluorescent probes to form double-stranded DNA (dsDNA) through the specific hybridization between target DNAs and ssDNA probes. And the dsDNA were released from the surface of MWCNTs@GONRs, which leaded the dual fluorescent probes to generate the strong fluorescent emissions (turning on). Therefore, this proposed homogeneous assay can be achieved to detect P35s and TNOS simultaneously by monitoring the relevant fluorescent emissions. Moreover, this assay can distinguish complementary and mismatched nucleic acid sequences with high sensitivity. The constructed approach has the potential to be a tool for daily detection of genetically modified organism with the merits of feasibility and reliability. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Simultaneous monitoring and compositions analysis of PM1 and PM2.5 in Shanghai: Implications for characterization of haze pollution and source apportionment.

    Science.gov (United States)

    Qiao, Ting; Zhao, Mengfei; Xiu, Guangli; Yu, Jianzhen

    2016-07-01

    A year-long simultaneous observation of PM1 and PM2.5 were conducted at ECUST campus in Shanghai, the compositions were analyzed and compared. Results showed that PM2.5 was dominated by PM1 on clear days while the contribution of PM1-2.5 to PM2.5 increased on haze days, indicating that PM2.5 should be given priority to characterize or predict haze pollution. On haze days, accumulation of organic carbon (OC), elemental carbon (EC) and primary organic carbon (POC) in PM1-2.5 was faster than that in PM1. Humic-like substances carbon (Hulis-C) in both PM2.5 and PM1 formed faster than water soluble organic carbon (WSOC) on haze days, hence Hulis-C/WSOC increased with the intensification of haze pollution. In terms of water soluble ions, NO3(-)/SO4(2-) in PM1 increased with the aggravation of haze pollution, implying that mobile sources dominated on haze days, so is nitrogen oxidation ratio (NOR). Liquid water content (LWC) in both PM1 and PM2.5 had positive correlations with relative humidity (RH) but negative correlations with visibility, implying that hygroscopic growth might be a factor for visibility impairment, especially LWC in PM1. By comparison with multi-linear equations of LWC in PM1 and PM2.5, NO3(-) exerted a higher influence on hygroscopicity of PM1 than PM2.5, while RH, WSOC, SO4(2-) and NH4(+) had higher effects on PM2.5, especially WSOC. Source apportionment of PM2.5 was also investigated to provide reference for policy making. Cluster analysis by HYSPLIT (HYbrid Single Particle Lagrangian Integrated Trajectory) model showed that PM2.5 originated from marine aerosols, middle-scale transportation and large-scale transportation. Furthermore, PM2.5 on haze days was dominated by middle-scale transportation. In line with source apportionment by positive matrix factorization (PMF) model, PM2.5 was attributed to secondary inorganics, aged sea salt, combustion emissions, hygroscopic growth and secondary organics. Secondary formation was the principle source of

  1. Simultaneous assessment of cytotoxic T lymphocyte responses against multiple viral infections by combined usage of optimal epitope matrices, anti- CD3 mAb T-cell expansion and "RecycleSpot"

    Directory of Open Access Journals (Sweden)

    Wong Johnson T

    2005-05-01

    Full Text Available Abstract The assessment of cellular anti-viral immunity is often hampered by the limited availability of adequate samples, especially when attempting simultaneous, high-resolution determination of T cell responses against multiple viral infections. Thus, the development of assay systems, which optimize cell usage, while still allowing for the detailed determination of breadth and magnitude of virus-specific cytotoxic T lymphocyte (CTL responses, is urgently needed. This study provides an up-to-date listing of currently known, well-defined viral CTL epitopes for HIV, EBV, CMV, HCV and HBV and describes an approach that overcomes some of the above limitations through the use of peptide matrices of optimally defined viral CTL epitopes in combination with anti-CD3 in vitro T cell expansion and re-use of cells from negative ELISpot wells. The data show that, when compared to direct ex vivo cell preparations, antigen-unspecific in vitro T cell expansion maintains the breadth of detectable T cell responses and demonstrates that harvesting cells from negative ELISpot wells for re-use in subsequent ELISpot assays (RecycleSpot, further maximized the use of available cells. Furthermore when combining T cell expansion and RecycleSpot with the use of rationally designed peptide matrices, antiviral immunity against more than 400 different CTL epitopes from five different viruses can be reproducibly assessed from samples of less than 10 milliliters of blood without compromising information on the breadth and magnitude of these responses. Together, these data support an approach that facilitates the assessment of cellular immunity against multiple viral co-infections in settings where sample availability is severely limited.

  2. Multiple sclerosis

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Kuehn, A.L.; Backens, M.; Papanagiotou, P.; Shariat, K.; Kostopoulos, P.

    2008-01-01

    Multiple sclerosis is the most common chronic inflammatory disease of myelin with interspersed lesions in the white matter of the central nervous system. Magnetic resonance imaging (MRI) plays a key role in the diagnosis and monitoring of white matter diseases. This article focuses on key findings in multiple sclerosis as detected by MRI. (orig.) [de

  3. Simultaneous use of several monitoring techniques to measure visitor load, spatio-temporal distribution and social characteristics of tourists - a case study of a cable car area in the Carpathian Mountains, Tatra National Park

    Science.gov (United States)

    Taczanowska, Karolina; Zięba, Antoni; Brandenburg, Christiane; Muhar, Andreas; Preisel, Hemma; Hibner, Joanna; Latosinska, Barbara; Benítez, Rafael; Bolós, Vicente; Toca-Herrera, José L.; Ziobrowski, Szymon

    2017-04-01

    Visitor monitoring is an integrate part of the effective management of recreational and protected areas. Comprehensive information concerning volume of tourist traffic, spatial-temporal distribution of visitors in a leisure setting as well as visitor socio-demographic characteristics may support understanding human behaviour and the ongoing natural processes (trail deterioration, erosion, impact on flora and fauna). Especially, vulnerable areas that in the same time serve as tourist attractions need to be carefully investigated. One of such areas is Kasprowy Wierch (1987 m.a.s.l.) - a popular cable car destination located in the Carpathian Mountains, Tatra National Park, Poland / Slovakia. The aim of this study was to define the overall visitor load and to understand visitor behaviour in the proximity of the upper cable car station at Kasprowy Wierch. The main focus of this presentation is the comparison of the used monitoring techniques and exposing the benefit of their simultaneous application. Visitor monitoring campaign was carried out in the study area in the summer season 2014. The following data collection techniques were simultaneously applied: 1) automatic counting (Eco-Counter pyroelectric sensors), 2) manual counting; 3) on-site interviews combined with trip diaries and visitor observation 4) GPS-tracking 5) registry of cable car tickets 6) registry of entries to the national park (TPN). Between 26.06.2014 and 30.09.2014 at 7 locations a continuous automatic counting of visitors was done using pyroelectric sensors (Eco-Counter). Additionally, on 18 sampling days at 12 locations direct observations (manual counting) of visitor flows was carried out. During the sampling days tourists were interviewed in the field using structured questionnaires (PAPI survey technique, N = 2639). Survey was combined with a documentation of visitors' trip itineraries via GPS-loggers and map sketches. Totally 1250 GPS-tracks of visitors and 1351 map sketches have been

  4. Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial.

    Science.gov (United States)

    Lind, Marcus; Polonsky, William; Hirsch, Irl B; Heise, Tim; Bolinder, Jan; Dahlqvist, Sofia; Schwarz, Erik; Ólafsdóttir, Arndís Finna; Frid, Anders; Wedel, Hans; Ahlén, Elsa; Nyström, Thomas; Hellman, Jarl

    2017-01-24

    The majority of individuals with type 1 diabetes do not meet recommended glycemic targets. To evaluate the effects of continuous glucose monitoring in adults with type 1 diabetes treated with multiple daily insulin injections. Open-label crossover randomized clinical trial conducted in 15 diabetes outpatient clinics in Sweden between February 24, 2014, and June 1, 2016 that included 161 individuals with type 1 diabetes and hemoglobin A1c (HbA1c) of at least 7.5% (58 mmol/mol) treated with multiple daily insulin injections. Participants were randomized to receive treatment using a continuous glucose monitoring system or conventional treatment for 26 weeks, separated by a washout period of 17 weeks. Difference in HbA1c between weeks 26 and 69 for the 2 treatments. Adverse events including severe hypoglycemia were also studied. Among 161 randomized participants, mean age was 43.7 years, 45.3% were women, and mean HbA1c was 8.6% (70 mmol/mol). A total of 142 participants had follow-up data in both treatment periods. Mean HbA1c was 7.92% (63 mmol/mol) during continuous glucose monitoring use and 8.35% (68 mmol/mol) during conventional treatment (mean difference, -0.43% [95% CI, -0.57% to -0.29%] or -4.7 [-6.3 to -3.1 mmol/mol]; P < .001). Of 19 secondary end points comprising psychosocial and various glycemic measures, 6 met the hierarchical testing criteria of statistical significance, favoring continuous glucose monitoring compared with conventional treatment. Five patients in the conventional treatment group and 1 patient in the continuous glucose monitoring group had severe hypoglycemia. During washout when patients used conventional therapy, 7 patients had severe hypoglycemia. Among patients with inadequately controlled type 1 diabetes treated with multiple daily insulin injections, the use of continuous glucose monitoring compared with conventional treatment for 26 weeks resulted in lower HbA1c. Further research is needed to assess clinical outcomes and longer

  5. New camera-based microswitch technology to monitor small head and mouth responses of children with multiple disabilities.

    Science.gov (United States)

    Lancioni, Giulio E; Bellini, Domenico; Oliva, Doretta; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Furniss, Fred

    2014-06-01

    Assessing a new camera-based microswitch technology, which did not require the use of color marks on the participants' face. Two children with extensive multiple disabilities participated. The responses selected for them consisted of small, lateral head movements and mouth closing or opening. The intervention was carried out according to a multiple probe design across responses. The technology involved a computer with a CPU using a 2-GHz clock, a USB video camera with a 16-mm lens, a USB cable connecting the camera and the computer, and a special software program written in ISO C++ language. The new technology was satisfactorily used with both children. Large increases in their responding were observed during the intervention periods (i.e. when the responses were followed by preferred stimulation). The new technology may be an important resource for persons with multiple disabilities and minimal motor behavior.

  6. Spatial Statistical and Modeling Strategy for Inventorying and Monitoring Ecosystem Resources at Multiple Scales and Resolution Levels

    Science.gov (United States)

    Robin M. Reich; C. Aguirre-Bravo; M.S. Williams

    2006-01-01

    A statistical strategy for spatial estimation and modeling of natural and environmental resource variables and indicators is presented. This strategy is part of an inventory and monitoring pilot study that is being carried out in the Mexican states of Jalisco and Colima. Fine spatial resolution estimates of key variables and indicators are outputs that will allow the...

  7. Multiple estimates of effective population size for monitoring a long-lived vertebrate: an application to Yellowstone grizzly bears.

    Science.gov (United States)

    Kamath, Pauline L; Haroldson, Mark A; Luikart, Gordon; Paetkau, David; Whitman, Craig; van Manen, Frank T

    2015-11-01

    Effective population size (N(e)) is a key parameter for monitoring the genetic health of threatened populations because it reflects a population's evolutionary potential and risk of extinction due to genetic stochasticity. However, its application to wildlife monitoring has been limited because it is difficult to measure in natural populations. The isolated and well-studied population of grizzly bears (Ursus arctos) in the Greater Yellowstone Ecosystem provides a rare opportunity to examine the usefulness of different N(e) estimators for monitoring. We genotyped 729 Yellowstone grizzly bears using 20 microsatellites and applied three single-sample estimators to examine contemporary trends in generation interval (GI), effective number of breeders (N(b)) and N(e) during 1982-2007. We also used multisample methods to estimate variance (N(eV)) and inbreeding N(e) (N(eI)). Single-sample estimates revealed positive trajectories, with over a fourfold increase in N(e) (≈100 to 450) and near doubling of the GI (≈8 to 14) from the 1980s to 2000s. N(eV) (240-319) and N(eI) (256) were comparable with the harmonic mean single-sample N(e) (213) over the time period. Reanalysing historical data, we found N(eV) increased from ≈80 in the 1910s-1960s to ≈280 in the contemporary population. The estimated ratio of effective to total census size (N(e) /N(c)) was stable and high (0.42-0.66) compared to previous brown bear studies. These results support independent demographic evidence for Yellowstone grizzly bear population growth since the 1980s. They further demonstrate how genetic monitoring of N(e) can complement demographic-based monitoring of N(c) and vital rates, providing a valuable tool for wildlife managers. © 2015 John Wiley & Sons Ltd.

  8. Multiple Time-Scale Monitoring to Address Dynamic Seasonality and Storm Pulses of Stream Water Quality in Mountainous Watersheds

    Directory of Open Access Journals (Sweden)

    Hyun-Ju Lee

    2015-11-01

    Full Text Available Rainfall variability and extreme events can amplify the seasonality and storm pulses of stream water chemistry in mountainous watersheds under monsoon climates. To establish a monitoring program optimized for identifying potential risks to stream water quality arising from rainfall variability and extremes, we examined water chemistry data collected on different timescales. At a small forested watershed, bi-weekly sampling lasted over two years, in comparison to three other biweekly sampling sites. In addition, high-frequency continuous measurements of pH, electrical conductivity, and turbidity were conducted in tandem with automatic water sampling at 2 h intervals during eight rainfall events. Biweekly monitoring showed that during the summer monsoon period, electrical conductivity (EC, dissolved oxygen (DO, and dissolved ion concentrations generally decreased, but total suspended solids (TSS slightly increased. A noticeable variation from the usual seasonal pattern was that DO levels substantially decreased during an extended drought. Bi-hourly storm event samplings exhibited large changes in the concentrations of TSS and particulate and dissolved organic carbon (POC; DOC during intense rainfall events. However, extreme fluctuations in sediment export during discharge peaks could be detected only by turbidity measurements at 5 min intervals. Concomitant measurements during rainfall events established empirical relationships between turbidity and TSS or POC. These results suggest that routine monitoring based on weekly to monthly sampling is valid only in addressing general seasonal patterns or long-lasting phenomena such as drought effects. We propose an “adaptive” monitoring scheme that combines routine monitoring for general seasonal patterns and high-frequency instrumental measurements of water quality components exhibiting rapid responses pulsing during intense rainfall events.

  9. Multiple estimates of effective population size for monitoring a long-lived vertebrate: An application to Yellowstone grizzly bears

    Science.gov (United States)

    Kamath, Pauline L.; Haroldson, Mark A.; Luikart, Gordon; Paetkau, David; Whitman, Craig L.; van Manen, Frank T.

    2015-01-01

    Effective population size (Ne) is a key parameter for monitoring the genetic health of threatened populations because it reflects a population's evolutionary potential and risk of extinction due to genetic stochasticity. However, its application to wildlife monitoring has been limited because it is difficult to measure in natural populations. The isolated and well-studied population of grizzly bears (Ursus arctos) in the Greater Yellowstone Ecosystem provides a rare opportunity to examine the usefulness of different Ne estimators for monitoring. We genotyped 729 Yellowstone grizzly bears using 20 microsatellites and applied three single-sample estimators to examine contemporary trends in generation interval (GI), effective number of breeders (Nb) and Ne during 1982–2007. We also used multisample methods to estimate variance (NeV) and inbreeding Ne (NeI). Single-sample estimates revealed positive trajectories, with over a fourfold increase in Ne (≈100 to 450) and near doubling of the GI (≈8 to 14) from the 1980s to 2000s. NeV (240–319) and NeI (256) were comparable with the harmonic mean single-sample Ne (213) over the time period. Reanalysing historical data, we found NeV increased from ≈80 in the 1910s–1960s to ≈280 in the contemporary population. The estimated ratio of effective to total census size (Ne/Nc) was stable and high (0.42–0.66) compared to previous brown bear studies. These results support independent demographic evidence for Yellowstone grizzly bear population growth since the 1980s. They further demonstrate how genetic monitoring of Ne can complement demographic-based monitoring of Nc and vital rates, providing a valuable tool for wildlife managers.

  10. Real-time particle monitor calibration factors and PM2.5 emission factors for multiple indoor sources.

    Science.gov (United States)

    Dacunto, Philip J; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Klepeis, Neil E; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2013-08-01

    Indoor sources can greatly contribute to personal exposure to particulate matter less than 2.5 μm in diameter (PM2.5). To accurately assess PM2.5 mass emission factors and concentrations, real-time particle monitors must be calibrated for individual sources. Sixty-six experiments were conducted with a common, real-time laser photometer (TSI SidePak™ Model AM510 Personal Aerosol Monitor) and a filter-based PM2.5 gravimetric sampler to quantify the monitor calibration factors (CFs), and to estimate emission factors for common indoor sources including cigarettes, incense, cooking, candles, and fireplaces. Calibration factors for these indoor sources were all significantly less than the factory-set CF of 1.0, ranging from 0.32 (cigarette smoke) to 0.70 (hamburger). Stick incense had a CF of 0.35, while fireplace emissions ranged from 0.44-0.47. Cooking source CFs ranged from 0.41 (fried bacon) to 0.65-0.70 (fried pork chops, salmon, and hamburger). The CFs of combined sources (e.g., cooking and cigarette emissions mixed) were linear combinations of the CFs of the component sources. The highest PM2.5 emission factors per time period were from burned foods and fireplaces (15-16 mg min(-1)), and the lowest from cooking foods such as pizza and ground beef (0.1-0.2 mg min(-1)).

  11. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    Science.gov (United States)

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for

  12. Development of a Machine Vision Method for the Monitoring of Laying Hens and Detection of Multiple Nest Occupations

    Directory of Open Access Journals (Sweden)

    Mauro Zaninelli

    2018-01-01

    Full Text Available Free range systems can improve the welfare of laying hens. However, the access to environmental resources can be partially limited by social interactions, feeding of hens, and productivity, can be not stable and damaging behaviors, or negative events, can be observed more frequently than in conventional housing systems. In order to reach a real improvement of the hens’ welfare the study of their laying performances and behaviors is necessary. With this purpose, many systems have been developed. However, most of them do not detect a multiple occupation of the nest negatively affecting the accuracy of data collected. To overcome this issue, a new “nest-usage-sensor” was developed and tested. It was based on the evaluation of thermografic images, as acquired by a thermo-camera, and the performing of patter recognitions on images acquired from the nest interior. The sensor was setup with a “Multiple Nest Occupation Threshold” of 796 colored pixels and a template of triangular shape and sizes of 43 × 33 pixels (high per base. It was tested through an experimental nesting system where 10 hens were reared for a month. Results showed that the evaluation of thermografic images could increase the detection performance of a multiple occupation of the nest and to apply an image pattern recognition technique could allow for counting the number of hens in the nest in case of a multiple occupation. As a consequence, the accuracy of data collected in studies on laying performances and behaviors of hens, reared in a free-range housing system, could result to be improved.

  13. Monitoring intracellular oxidative events using dynamic spectral unmixing microscopy

    Science.gov (United States)

    There is increasing interest in using live-cell imaging to monitor not just individual intracellular endpoints, but to investigate the interplay between multiple molecular events as they unfold in real time within the cell. A major impediment to simultaneous acquisition of multip...

  14. Simultaneous determination of ten antiepileptic drugs in human plasma by liquid chromatography and tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application in therapeutic drug monitoring.

    Science.gov (United States)

    Yin, Lei; Wang, Tingting; Shi, Meiyun; Zhang, Ying; Zhao, Xiaojun; Yang, Yan; Gu, Jingkai

    2016-03-01

    A simple, rapid, and high-throughput liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of ten antiepileptic drugs in human plasma has been developed and validated. The method required only 10 μL of plasma. After simple protein precipitation using acetonitrile, the analytes and internal standard diphenhydramine were separated on a Zorbax SB-C18 column (50 × 4.6 mm, 2.7 μm) using acetonitrile/water as the mobile phase at a flow rate of 0.9 mL/min. The total run time was 6 min for each sample. The validation results of specificity, matrix effects, recovery, linearity, precision, and accuracy were satisfactory. The lower limit of quantification was 0.04 μg/mL for carbamazepine, 0.02 μg/mL for lamotrigine, 0.01 μg/mL for oxcarbazepine, 0.4 μg/mL for 10-hydroxycarbazepine, 0.1 μg/mL for carbamazepine-10,11-epoxide, 0.15 μg/mL for levetiracetam, 0.06 μg/mL for phenytoin, 0.3 μg/mL for valproic acid, 0.03 μg/mL for topiramate, and 0.15 μg/mL for phenobarbital. The intraday precision and interday precision were less than 7.6%, with the accuracy ranging between -8.1 and 7.9%. The method was successfully applied to therapeutic drug monitoring of 1237 patients with epilepsy after administration of standard antiepileptic drugs. The method has been proved to meet the high-throughput requirements in therapeutic drug monitoring. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A clinical decision-making mechanism for context-aware and patient-specific remote monitoring systems using the correlations of multiple vital signs.

    Science.gov (United States)

    Forkan, Abdur Rahim Mohammad; Khalil, Ibrahim

    2017-02-01

    In home-based context-aware monitoring patient's real-time data of multiple vital signs (e.g. heart rate, blood pressure) are continuously generated from wearable sensors. The changes in such vital parameters are highly correlated. They are also patient-centric and can be either recurrent or can fluctuate. The objective of this study is to develop an intelligent method for personalized monitoring and clinical decision support through early estimation of patient-specific vital sign values, and prediction of anomalies using the interrelation among multiple vital signs. In this paper, multi-label classification algorithms are applied in classifier design to forecast these values and related abnormalities. We proposed a completely new approach of patient-specific vital sign prediction system using their correlations. The developed technique can guide healthcare professionals to make accurate clinical decisions. Moreover, our model can support many patients with various clinical conditions concurrently by utilizing the power of cloud computing technology. The developed method also reduces the rate of false predictions in remote monitoring centres. In the experimental settings, the statistical features and correlations of six vital signs are formulated as multi-label classification problem. Eight multi-label classification algorithms along with three fundamental machine learning algorithms are used and tested on a public dataset of 85 patients. Different multi-label classification evaluation measures such as Hamming score, F1-micro average, and accuracy are used for interpreting the prediction performance of patient-specific situation classifications. We achieved 90-95% Hamming score values across 24 classifier combinations for 85 different patients used in our experiment. The results are compared with single-label classifiers and without considering the correlations among the vitals. The comparisons show that multi-label method is the best technique for this problem

  16. Different scale land subsidence and ground fissure monitoring with multiple InSAR techniques over Fenwei basin, China

    Directory of Open Access Journals (Sweden)

    C. Zhao

    2015-11-01

    Full Text Available Fenwei basin, China, composed by several sub-basins, has been suffering severe geo-hazards in last 60 years, including large scale land subsidence and small scale ground fissure, which caused serious infrastructure damages and property losses. In this paper, we apply different InSAR techniques with different SAR data to monitor these hazards. Firstly, combined small baseline subset (SBAS InSAR method and persistent scatterers (PS InSAR method is used to multi-track Envisat ASAR data to retrieve the large scale land subsidence covering entire Fenwei basin, from which different land subsidence magnitudes are analyzed of different sub-basins. Secondly, PS-InSAR method is used to monitor the small scale ground fissure deformation in Yuncheng basin, where different spatial deformation gradient can be clearly discovered. Lastly, different track SAR data are contributed to retrieve two-dimensional deformation in both land subsidence and ground fissure region, Xi'an, China, which can be benefitial to explain the occurrence of ground fissure and the correlation between land subsidence and ground fissure.

  17. Early Prognostic Value of Monitoring Serum Free Light Chain in Patients with Multiple Myeloma Undergoing Autologous Stem Cell Transplantation.

    Science.gov (United States)

    Özkurt, Zübeyde Nur; Sucak, Gülsan Türköz; Akı, Şahika Zeynep; Yağcı, Münci; Haznedar, Rauf

    2017-03-16

    We hypothesized the levels of free light chains obtained before and after autologous stem cell transplantation can be useful in predicting transplantation outcome. We analyzed 70 multiple myeloma patients. Abnormal free light chain ratios before stem cell transplantation were found to be associated early progression, although without any impact on overall survival. At day +30, the normalization of levels of involved free light chain related with early progression. According to these results almost one-third reduction of free light chain levels can predict favorable prognosis after autologous stem cell transplantation.

  18. Simultaneous monitoring of the two coupled motors of a single FoF1-ATP synthase by three-color FRET using duty cycle-optimized triple-ALEX

    Science.gov (United States)

    Zarrabi, N.; Ernst, S.; Düser, M. G.; Golovina-Leiker, A.; Becker, W.; Erdmann, R.; Dunn, S. D.; Börsch, M.

    2009-02-01

    FoF1-ATP synthase is the enzyme that provides the 'chemical energy currency' adenosine triphosphate, ATP, for living cells. The formation of ATP is accomplished by a stepwise internal rotation of subunits within the enzyme. Briefly, proton translocation through the membrane-bound Fo part of ATP synthase drives a 10-step rotary motion of the ring of c subunits with respect to the non-rotating subunits a and b. This rotation is transmitted to the γ and ɛ subunits of the F1 sector resulting in 120° steps. In order to unravel this symmetry mismatch we monitor subunit rotation by a single-molecule fluorescence resonance energy transfer (FRET) approach using three fluorophores specifically attached to the enzyme: one attached to the F1 motor, another one to the Fo motor, and the third one to a non-rotating subunit. To reduce photophysical artifacts due to spectral fluctuations of the single fluorophores, a duty cycle-optimized alternating three-laser scheme (DCO-ALEX) has been developed. Simultaneous observation of the stepsizes for both motors allows the detection of reversible elastic deformations between the rotor parts of Fo and F1.

  19. Cosmic Rays and Dynamical Meteorology, 2. Snow Effect In Different Multiplicities According To Neutron Monitor Data of Emilio Segre' Observatory

    Science.gov (United States)

    Dorman, L. I.; Iucci, N.; Pustil'Nik, L. A.; Sternlieb, A.; Villoresi, G.; Zukerman, I. G.

    On the basis of cosmic ray hourly data obtained by NM of Emilio Segre' Observatory (hight 2025 m above s.l., cut-off rigidity for vertical direction 10.8 GV) we determine the snow effect in CR for total neutron intensity and for multiplicities m=1, m=2, m=3, m=4, m=5, m=6, and m=7. For comparison and excluding primary CR variations we use also hourly data on neutron multiplicities obtained by Rome NM (about sea level, cut-off rigidity 6.7 GV). In this paper we will analize effects of snow in periods from 4 January 2000 to 15 April 2000 with maximal absorption effect about 5%, and from 21 December 2000 up to 31 March 2001 with maximal effect 13% in the total neu- tron intensity. We use the periods without snow to determine regeression coefficients between primary CR variations observed by NM of Emilio Segre' Observatory, and by Rome NM. On the basis of obtained results we develop a method to correct data on snow effect by using several NM hourly data. On the basis of our data we estimate the accuracy with what can be made correction of NM data of stations where the snow effect can be important.

  20. Design and First Results of an UAV-Borne L-Band Radiometer for Multiple Monitoring Purposes

    Directory of Open Access Journals (Sweden)

    Rene Acevo-Herrera

    2010-06-01

    Full Text Available UAV (unmanned Aerial Vehicle platforms represent a challenging opportunity for the deployment of a number of remote sensors. These vehicles are a cost-effective option in front of manned aerial vehicles (planes and helicopters, are easy to deploy due to the short runways needed, and they allow users to meet the critical requirements of the spatial and temporal resolutions imposed by the instruments. L-band radiometers are an interesting option for obtaining soil moisture maps over local areas with relatively high spatial resolution for precision agriculture, coastal monitoring, estimation of the risk of fires, flood prevention, etc. This paper presents the design of a light-weight, airborne L-band radiometer for deployment in a small UAV, including the hardware and specific software developed for calibration, geo-referencing, and soil moisture retrieval. First results and soil moisture retrievals from different field experiments are presented.

  1. Quantitative detection of multiple fluorophore sites as a tool for diagnosis and monitoring disease progression in salivary glands

    Science.gov (United States)

    Gannot, Israel; Bonner, Robert F.; Gannot, Gallya; Fox, Philip C.; You, Joon S.; Waynant, Ronald W.; Gandjbakhche, Amir H.

    1997-08-01

    A series of fluorescent surface images were obtained from physical models of localized fluorophores embedded at various depths and separations in tissue phantoms. Our random walk theory was applied to create an analytical model of multiple flurophores embedded in tissue-like phantom. Using this model, from acquired set of surface images, the location of the fluorophores was reconstructed and compared it to their known 3-D distributions. A good correlation was found, and the ability to resolve fluorophores as a function of depth and separation was determined. In parallel in in-vitro study, specific coloring of sections of minor salivary glands was also demonstrated. These results demonstrate the possibility of using inverse methods to reconstruct unknown locations and concentrations of optical probes specifically bound to infiltrating lymphocytes in minor salivary glands of patients with Sjogren's syndrome.

  2. Tool Wear Prediction in Ti-6Al-4V Machining through Multiple Sensor Monitoring and PCA Features Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Alessandra Caggiano

    2018-03-01

    Full Text Available Machining of titanium alloys is characterised by extremely rapid tool wear due to the high cutting temperature and the strong adhesion at the tool-chip and tool-workpiece interface, caused by the low thermal conductivity and high chemical reactivity of Ti alloys. With the aim to monitor the tool conditions during dry turning of Ti-6Al-4V alloy, a machine learning procedure based on the acquisition and processing of cutting force, acoustic emission and vibration sensor signals during turning is implemented. A number of sensorial features are extracted from the acquired sensor signals in order to feed machine learning paradigms based on artificial neural networks. To reduce the large dimensionality of the sensorial features, an advanced feature extraction methodology based on Principal Component Analysis (PCA is proposed. PCA allowed to identify a smaller number of features (k = 2 features, the principal component scores, obtained through linear projection of the original d features into a new space with reduced dimensionality k = 2, sufficient to describe the variance of the data. By feeding artificial neural networks with the PCA features, an accurate diagnosis of tool flank wear (VBmax was achieved, with predicted values very close to the measured tool wear values.

  3. Tool Wear Prediction in Ti-6Al-4V Machining through Multiple Sensor Monitoring and PCA Features Pattern Recognition.

    Science.gov (United States)

    Caggiano, Alessandra

    2018-03-09

    Machining of titanium alloys is characterised by extremely rapid tool wear due to the high cutting temperature and the strong adhesion at the tool-chip and tool-workpiece interface, caused by the low thermal conductivity and high chemical reactivity of Ti alloys. With the aim to monitor the tool conditions during dry turning of Ti-6Al-4V alloy, a machine learning procedure based on the acquisition and processing of cutting force, acoustic emission and vibration sensor signals during turning is implemented. A number of sensorial features are extracted from the acquired sensor signals in order to feed machine learning paradigms based on artificial neural networks. To reduce the large dimensionality of the sensorial features, an advanced feature extraction methodology based on Principal Component Analysis (PCA) is proposed. PCA allowed to identify a smaller number of features ( k = 2 features), the principal component scores, obtained through linear projection of the original d features into a new space with reduced dimensionality k = 2, sufficient to describe the variance of the data. By feeding artificial neural networks with the PCA features, an accurate diagnosis of tool flank wear ( VB max ) was achieved, with predicted values very close to the measured tool wear values.

  4. Tool Wear Prediction in Ti-6Al-4V Machining through Multiple Sensor Monitoring and PCA Features Pattern Recognition

    Science.gov (United States)

    2018-01-01

    Machining of titanium alloys is characterised by extremely rapid tool wear due to the high cutting temperature and the strong adhesion at the tool-chip and tool-workpiece interface, caused by the low thermal conductivity and high chemical reactivity of Ti alloys. With the aim to monitor the tool conditions during dry turning of Ti-6Al-4V alloy, a machine learning procedure based on the acquisition and processing of cutting force, acoustic emission and vibration sensor signals during turning is implemented. A number of sensorial features are extracted from the acquired sensor signals in order to feed machine learning paradigms based on artificial neural networks. To reduce the large dimensionality of the sensorial features, an advanced feature extraction methodology based on Principal Component Analysis (PCA) is proposed. PCA allowed to identify a smaller number of features (k = 2 features), the principal component scores, obtained through linear projection of the original d features into a new space with reduced dimensionality k = 2, sufficient to describe the variance of the data. By feeding artificial neural networks with the PCA features, an accurate diagnosis of tool flank wear (VBmax) was achieved, with predicted values very close to the measured tool wear values. PMID:29522443

  5. CSI 2264: simultaneous optical and infrared light curves of young disk-bearing stars in NGC 2264 with CoRoT and Spitzer—evidence for multiple origins of variability

    International Nuclear Information System (INIS)

    Cody, Ann Marie; Stauffer, John; Rebull, Luisa M.; Carey, Sean; Baglin, Annie; Micela, Giuseppina; Flaccomio, Ettore; Morales-Calderón, María; Aigrain, Suzanne; Bouvier, Jèrôme; Hillenbrand, Lynne A.; Carpenter, John; Findeisen, Krzysztof; Gutermuth, Robert; Song, Inseok; Turner, Neal; Alencar, Silvia H. P.; Zwintz, Konstanze; Plavchan, Peter; Terebey, Susan

    2014-01-01

    We present the Coordinated Synoptic Investigation of NGC 2264, a continuous 30 day multi-wavelength photometric monitoring campaign on more than 1000 young cluster members using 16 telescopes. The unprecedented combination of multi-wavelength, high-precision, high-cadence, and long-duration data opens a new window into the time domain behavior of young stellar objects. Here we provide an overview of the observations, focusing on results from Spitzer and CoRoT. The highlight of this work is detailed analysis of 162 classical T Tauri stars for which we can probe optical and mid-infrared flux variations to 1% amplitudes and sub-hour timescales. We present a morphological variability census and then use metrics of periodicity, stochasticity, and symmetry to statistically separate the light curves into seven distinct classes, which we suggest represent different physical processes and geometric effects. We provide distributions of the characteristic timescales and amplitudes and assess the fractional representation within each class. The largest category (>20%) are optical 'dippers' with discrete fading events lasting ∼1-5 days. The degree of correlation between the optical and infrared light curves is positive but weak; notably, the independently assigned optical and infrared morphology classes tend to be different for the same object. Assessment of flux variation behavior with respect to (circum)stellar properties reveals correlations of variability parameters with Hα emission and with effective temperature. Overall, our results point to multiple origins of young star variability, including circumstellar obscuration events, hot spots on the star and/or disk, accretion bursts, and rapid structural changes in the inner disk.

  6. Multiple Lines Of Evidence Supporting Natural Attenuation: Lines Of Inquiry Supporting Monitored Natural Attenuation And Enhanced Attenuatin Of Chlorinated Solvents

    Energy Technology Data Exchange (ETDEWEB)

    Vangelas, Karen; Widemeirer, T. H.; Barden, M.J.; Dickson, W. Z.; Major, David

    2004-12-31

    The Department of Energy (DOE) is sponsoring an initiative to facilitate efficient, effective and responsible use of Monitored Natural Attenuation (MNA) and Enhanced Attenuation (EA) for chlorinated solvents. This Office of Environmental Management (EM) ''Alternative Project,'' focuses on providing scientific and policy support for MNA/EA. A broadly representative working group of scientists supports the project along with partnerships with regulatory organizations such as the Interstate Technology Regulatory Council (ITRC) and the United States Environmental Protection Agency (USEPA). The initial product of the technical working group was a summary report that articulated the conceptual approach and central scientific tenants of the project, and that identified a prioritized listing of technical targets for field research. This report documented the process in which: (1) scientific ground rules were developed, (2) lines of inquiry were identified and then critically evaluated, (3) promising applied research topics were highlighted in the various lines of inquiry, and (4) these were discussed and prioritized. The summary report will serve as a resource to guide management and decision making throughout the period of the subject MNA/EA Alternative Project. To support and more fully document the information presented in the summary report, the DOE is publishing a series of supplemental documents that present the full texts from the technical analyses within the various lines of inquiry (see listing). The following report--documenting our evaluation of the state of the science for the lines of evidence for supporting decision-making for MNA--is one of those supplemental documents.

  7. A sensitive mass spectrometric method for hypothesis-driven detection of peptide post-translational modifications: multiple reaction monitoring-initiated detection and sequencing (MIDAS).

    Science.gov (United States)

    Unwin, Richard D; Griffiths, John R; Whetton, Anthony D

    2009-01-01

    The application of a targeted mass spectrometric workflow to the sensitive identification of post-translational modifications is described. This protocol employs multiple reaction monitoring (MRM) to search for all putative peptides specifically modified in a target protein. Positive MRMs trigger an MS/MS experiment to confirm the nature and site of the modification. This approach, termed MIDAS (MRM-initiated detection and sequencing), is more sensitive than approaches using neutral loss scanning or precursor ion scanning methodologies, due to a more efficient use of duty cycle along with a decreased background signal associated with MRM. We describe the use of MIDAS for the identification of phosphorylation, with a typical experiment taking just a couple of hours from obtaining a peptide sample. With minor modifications, the MIDAS method can be applied to other protein modifications or unmodified peptides can be used as a MIDAS target.

  8. Lymphocytes with multiple chromosomal damages in a large cohort of West Siberia residents: Results of long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Druzhinin, Vladimir [Kemerovo State University, Kemerovo (Russian Federation); Federal State Budget Scientific Institution «The Federal Research Center of Coal and Coal Chemistry of Siberian Branch of the Russian Academy of Sciences», Kemerovo (Russian Federation); Bakanova, Maria [Federal State Budget Scientific Institution «The Federal Research Center of Coal and Coal Chemistry of Siberian Branch of the Russian Academy of Sciences», Kemerovo (Russian Federation); Fucic, Aleksandra, E-mail: afucic@imi.hr [Institute for Medical Research and Occupational Health, Zagreb (Croatia); Golovina, Tatiana [Kemerovo State University, Kemerovo (Russian Federation); Savchenko, Yana [Federal State Budget Scientific Institution «The Federal Research Center of Coal and Coal Chemistry of Siberian Branch of the Russian Academy of Sciences», Kemerovo (Russian Federation); Sinitsky, Maxim; Volobaev, Valentin [Kemerovo State University, Kemerovo (Russian Federation)

    2016-02-15

    Highlights: • Study reports RC frequency in lymphocytes in the group of 3242 subjects. • The highest RC frequency was present in children environmentally exposed to radon. • In 85% of RCs double minutes were observed. • Results suggests that radon may be the leading factors causing RC. • RC may be a candidate biomarker for exposure to α-emitters. - Abstract: Cells with specific multiple chromosome aberrations, defined as rogue cells (RC) have been described in different populations, predominantly those exposed to radiation. The frequency, etiology and related health risks have still not been elucidated due to their low frequency of occurrences and rarely performed studies. This study reports RC frequency using chromosome aberration (CA) assay in peripheral lymphocytes in the group of 3242 subjects, during a 30-year long follow-up study in a general rural and urban population, children environmentally exposed to radon, occupationally exposed population and lung cancer patients from the Kemerovo region (Siberia, Russian Federation). Results show that the highest RC frequency was present in children environmentally exposed to radon and the lowest in the general urban population. Total frequency of CA did not correlate with frequency of RC. Genotoxic analysis of air and water samples excluded anthropogenic pollution as a possible cause of genome damage and RC frequency. In 85% of RCs, double minutes, observed in a large number of human tumors, were present. Results of CA analysis suggested that radon and its decay products (alpha-emitters) were the leading factors causing RC in subjects exposed to high LET radiation. Thus, RC may be a candidate biomarker for exposure to this type of radiation.

  9. Study of the variation of schistosomiasis risk in Lake Poyang in the People’s Republic of China using multiple space-borne sensors for monitoring and modelling

    Directory of Open Access Journals (Sweden)

    Kuo-Hsin Tseng

    2014-05-01

    Full Text Available The dynamics of the Poyang Lake in Jiangxi province, People’s Republic of China has been monitored to demonstrate the association of various variables with the distribution of schistosomiasis transmission with particular reference to the annual variation of the habitats for the Oncomelania snail, the intermediate host of Schistosoma japonicum. This was studied with multiple space-borne sensors, including the ENVISAT radar altimeter (RA-2 and MODIS/Terra radiometry data products such as the 16-day enhanced vegetation index, the 8-day sun reflectance, and the derived modified normalized difference water index. The measurements of physical properties were in good accordance with previous reports based on in situ gauge data, spectroradiometry and other optical methods, which encouraged us to build a predictive model based on reported geospatial constraints to assess the limits of potential variation of the snail habitat areas. The simulated results correspond fairly well with surveys conducted by local authorities showing a correlation coefficient of 0.82 between highpotential habitat areas and local estimates in a 9-year (2002-2010 analysis. Taken together, these data indicate that spaceborne observations and in situ measurements can be integrated and used as a first step of a monitoring system for control and analysis of the potential of schistosomiasis dissemination. Since the true range and intensity of transmission in the study region remain elusive at present, a long-term survey around the lake is warranted to build a robust, parametric model.

  10. Monitoring Recent Fluctuations of the Southern Pool of Lake Chad Using Multiple Remote Sensing Data: Implications for Water Balance Analysis

    Directory of Open Access Journals (Sweden)

    Wenbin Zhu

    2017-10-01

    Full Text Available The drought episodes in the second half of the 20th century have profoundly modified the state of Lake Chad and investigation of its variations is necessary under the new circumstances. Multiple remote sensing observations were used in this paper to study its variation in the recent 25 years. Unlike previous studies, only the southern pool of Lake Chad (SPLC was selected as our study area, because it is the only permanent open water area after the serious lake recession in 1973–1975. Four satellite altimetry products were used for water level retrieval and 904 Landsat TM/ETM+ images were used for lake surface area extraction. Based on the water level (L and surface area (A retrieved (with coinciding dates, linear regression method was used to retrieve the SPLC’s L-A curve, which was then integrated to estimate water volume variations ( Δ V . The results show that the SPLC has been in a relatively stable phase, with a slight increasing trend from 1992 to 2016. On annual average scale, the increase rate of water level, surface area and water volume is 0.5 cm year−1, 0.14 km2 year−1 and 0.007 km3 year−1, respectively. As for the intra-annual variations of the SPLC, the seasonal variation amplitude of water level, lake area and water volume is 1.38 m, 38.08 km2 and 2.00 km3, respectively. The scatterplots between precipitation and Δ V indicate that there is a time lag of about one to two months in the response of water volume variations to precipitation, which makes it possible for us to predict Δ V . The water balance of the SPLC is significantly different from that of the entire Lake Chad. While evaporation accounts for 96% of the lake’s total water losses, only 16% of the SPLC’s losses are consumed by evaporation, with the other 84% offset by outflow.

  11. Using the expected detection delay to assess the performance of different multivariate statistical process monitoring methods for multiplicative and drift faults.

    Science.gov (United States)

    Zhang, Kai; Shardt, Yuri A W; Chen, Zhiwen; Peng, Kaixiang

    2017-03-01

    Using the expected detection delay (EDD) index to measure the performance of multivariate statistical process monitoring (MSPM) methods for constant additive faults have been recently developed. This paper, based on a statistical investigation of the T 2 - and Q-test statistics, extends the EDD index to the multiplicative and drift fault cases. As well, it is used to assess the performance of common MSPM methods that adopt these two test statistics. Based on how to use the measurement space, these methods can be divided into two groups, those which consider the complete measurement space, for example, principal component analysis-based methods, and those which only consider some subspace that reflects changes in key performance indicators, such as partial least squares-based methods. Furthermore, a generic form for them to use T 2 - and Q-test statistics are given. With the extended EDD index, the performance of these methods to detect drift and multiplicative faults is assessed using both numerical simulations and the Tennessee Eastman process. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  13. Monitoring Cloud-prone Complex Landscapes At Multiple Spatial Scales Using Medium And High Resolution Optical Data: A Case Study In Central Africa

    Science.gov (United States)

    Basnet, Bikash

    Tracking land surface dynamics over cloud-prone areas with complex mountainous terrain and a landscape that is heterogeneous at a scale of approximately 10 m, is an important challenge in the remote sensing of tropical regions in developing nations, due to the small plot sizes. Persistent monitoring of natural resources in these regions at multiple spatial scales requires development of tools to identify emerging land cover transformation due to anthropogenic causes, such as agricultural expansion and climate change. Along with the cloud cover and obstructions by topographic distortions due to steep terrain, there are limitations to the accuracy of monitoring change using available historical satellite imagery, largely due to sparse data access and the lack of high quality ground truth for classifier training. One such complex region is the Lake Kivu region in Central Africa. This work addressed these problems to create an effective process for monitoring the Lake Kivu region located in Central Africa. The Lake Kivu region is a biodiversity hotspot with a complex and heterogeneous landscape and intensive agricultural development, where individual plot sizes are often at the scale of 10m. Procedures were developed that use optical data from satellite and aerial observations at multiple scales to tackle the monitoring challenges. First, a novel processing chain was developed to systematically monitor the spatio-temporal land cover dynamics of this region over the years 1988, 2001, and 2011 using Landsat data, complemented by ancillary data. Topographic compensation was performed on Landsat reflectances to avoid the strong illumination angle impacts and image compositing was used to compensate for frequent cloud cover and thus incomplete annual data availability in the archive. A systematic supervised classification, using the state-of-the-art machine learning classifier Random Forest, was applied to the composite Landsat imagery to obtain land cover thematic maps

  14. Multiple Perspectives / Multiple Readings

    Directory of Open Access Journals (Sweden)

    Simon Biggs

    2005-01-01

    Full Text Available People experience things from their own physical point of view. What they see is usually a function of where they are and what physical attitude they adopt relative to the subject. With augmented vision (periscopes, mirrors, remote cameras, etc we are able to see things from places where we are not present. With time-shifting technologies, such as the video recorder, we can also see things from the past; a time and a place we may never have visited.In recent artistic work I have been exploring the implications of digital technology, interactivity and internet connectivity that allow people to not so much space/time-shift their visual experience of things but rather see what happens when everybody is simultaneously able to see what everybody else can see. This is extrapolated through the remote networking of sites that are actual installation spaces; where the physical movements of viewers in the space generate multiple perspectives, linked to other similar sites at remote locations or to other viewers entering the shared data-space through a web based version of the work.This text explores the processes involved in such a practice and reflects on related questions regarding the non-singularity of being and the sense of self as linked to time and place.

  15. Preferences for Simultaneous Polydrug Use:

    DEFF Research Database (Denmark)

    Østergaard, Jeanette; Østergaard, Stine Vernstrøm; Fletcher, Adam

    2016-01-01

    among those reporting drug use, according to sociodemographics, alcohol intake, frequency of intoxication, and smoking. Illicit drug use was more prevalent among young adults in England than Denmark. The difference was smallest for cannabis use: Lifetime cannabis use is 66% in England and 58% in Denmark......Cross-national surveys of young adults’ simultaneous polydrug use (SPU) are rare, as measuring polydrug use requires multiple questions capturing the timing, sequence, and dosage of mixing drugs. This study proposes a new way of measuring SPU by examining how preferences for simultaneous polydrug...... use (PSPU) vary among club/bar-goers in two European countries, Denmark and England, typically cited as exemplars of the normalization of illegal drug use. The study considers the utility of the normalization thesis for understanding preferences for polydrug use in the European nighttime economy...

  16. Using multiple continuous fine particle monitors to characterize tobacco, incense, candle, cooking, wood burning, and vehicular sources in indoor, outdoor, and in-transit settings

    Science.gov (United States)

    Ott, Wayne R.; Siegmann, Hans C.

    This study employed two continuous particle monitors operating on different measurement principles to measure concentrations simultaneously from common combustion sources in indoor, outdoor, and in-transit settings. The pair of instruments use (a) photo-charging (PC) operating on the principle ionization of fine particles that responds to surface particulate polycyclic aromatic hydrocarbons (PPAHs), and (b) diffusion charging (DC) calibrated to measure the active surface area of fine particles. The sources studied included: (1) secondhand smoke (cigarettes, cigars, and pipes), (2) incense (stick and cone), (3) candles used as food warmers, (4) cooking (toasting bread and frying meat), (5) fireplaces and ambient wood smoke, and (6) in-vehicle exposures traveling on California arterials and interstate highways. The ratio of the PC to the DC readings, or the PC/DC ratio, was found to be different for major categories of sources. Cooking, burning toast, and using a "canned heat" food warmer gave PC/DC ratios close to zero. Controlled experiments with 10 cigarettes averaged 0.15 ng mm -2 (ranging from 0.11 to 0.19 ng mm -2), which was similar to the PC/DC ratio for a cigar, although a pipe was slightly lower (0.09 ng mm -2). Large incense sticks had PC/DC ratios similar to those of cigarettes and cigars. The PC/DC ratios for ambient wood smoke averaged 0.29 ng mm -2 on 6 dates, or about twice those of cigarettes and cigars, reflecting a higher ratio of PAH to active surface area. The smoke from two artificial logs in a residential fireplace had a PC/DC ratio of 0.33-0.35 ng mm -2. The emissions from candles were found to vary, depending on how the candles were burned. If the candle flickered and generated soot, a higher PC/DC ratio resulted than if the candle burned uniformly in still air. Inserting piece of metal into the candle's flame caused high PPAH emissions with a record PC/DC reading of 1.8 ng mm -2. In-vehicle exposures measured on 43- and 50-min drives on a

  17. Selective and rapid monitoring of dual platelet inhibition by aspirin and P2Y12 antagonists by using multiple electrode aggregometry

    Directory of Open Access Journals (Sweden)

    Lorenz Reinhard

    2010-05-01

    Full Text Available Abstract Background Poor platelet inhibition by aspirin or clopidogrel has been associated with adverse outcomes in patients with cardiovascular diseases. A reliable and facile assay to measure platelet inhibition after treatment with aspirin and a P2Y12 antagonist is lacking. Multiple electrode aggregometry (MEA, which is being increasingly used in clinical studies, is sensitive to platelet inhibition by aspirin and clopidogrel, but a critical evaluation of MEA monitoring of dual anti-platelet therapy with aspirin and P2Y12 antagonists is missing. Design and Methods By performing in vitro and ex vivo experiments, we evaluated in healthy subjects the feasibility of using MEA to monitor platelet inhibition of P2Y12 antagonists (clopidogrel in vivo, cangrelor in vitro and aspirin (100 mg per day in vivo, and 1 mM or 5.4 mM in vitro alone, and in combination. Statistical analyses were performed by the Mann-Whitney rank sum test, student' t-test, analysis of variance followed by the Holm-Sidak test, where appropriate. Results ADP-induced platelet aggregation in hirudin-anticoagulated blood was inhibited by 99.3 ± 1.4% by in vitro addition of cangrelor (100 nM; p 95% and 100 ± 3.2%, respectively (p in vitro or ex vivo. Oral intake of clopidogrel did not significantly reduce AA-induced aggregation, but P2Y12 blockade by cangrelor (100 nM in vitro diminished AA-stimulated aggregation by 53 ± 26% (p Conclusions Selective platelet inhibition by aspirin and P2Y12 antagonists alone and in combination can be rapidly measured by MEA. We suggest that dual anti-platelet therapy with these two types of anti-platelet drugs can be optimized individually by measuring platelet responsiveness to ADP and AA with MEA before and after drug intake.

  18. Intact protein analysis of ubiquitin in cerebrospinal fluid by multiple reaction monitoring reveals differences in Alzheimer's disease and frontotemporal lobar degeneration.

    Science.gov (United States)

    Oeckl, Patrick; Steinacker, Petra; von Arnim, Christine A F; Straub, Sarah; Nagl, Magdalena; Feneberg, Emily; Weishaupt, Jochen H; Ludolph, Albert C; Otto, Markus

    2014-11-07

    The impairment of the ubiquitin-proteasome system (UPS) is thought to be an early event in neurodegeneration, and monitoring UPS alterations might serve as a disease biomarker. Our aim was to establish an alternate method to antibody-based assays for the selective measurement of free monoubiquitin in cerebrospinal fluid (CSF). Free monoubiquitin was measured with liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MS/MS) in CSF of patients with Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), behavioral variant of frontotemporal dementia (bvFTD), Creutzfeldt-Jakob disease (CJD), Parkinson's disease (PD), primary progressive aphasia (PPA), and progressive supranuclear palsy (PSP). The LC-MS/MS method showed excellent intra- and interassay precision (4.4-7.4% and 4.9-10.3%) and accuracy (100-107% and 100-106%). CSF ubiquitin concentration was increased compared with that of controls (33.0 ± 9.7 ng/mL) in AD (47.5 ± 13.1 ng/mL, p < 0.05) and CJD patients (171.5 ± 103.5 ng/mL, p < 0.001) but not in other neurodegenerative diseases. Receiver operating characteristic curve (ROC) analysis of AD vs control patients revealed an area under the curve (AUC) of 0.832, and the specificity and sensitivity were 75 and 75%, respectively. ROC analysis of AD and FTLD patients yielded an AUC of 0.776, and the specificity and sensitivity were 53 and 100%, respectively. In conclusion, our LC-MS/MS method may facilitate ubiquitin determination to a broader community and might help to discriminate AD, CJD, and FTLD patients.

  19. Simultaneous Cake Cutting

    DEFF Research Database (Denmark)

    Balkanski, Eric; Branzei, Simina; Kurokawa, David

    2014-01-01

    We introduce the simultaneous model for cake cutting (the fair allocation of a divisible good), in which agents simultaneously send messages containing a sketch of their preferences over the cake. We show that this model enables the computation of divisions that satisfy proportionality — a popular...

  20. [Multiple meningiomas].

    Science.gov (United States)

    Terrier, L-M; François, P

    2016-06-01

    Multiple meningiomas (MMs) or meningiomatosis are defined by the presence of at least 2 lesions that appear simultaneously or not, at different intracranial locations, without the association of neurofibromatosis. They present 1-9 % of meningiomas with a female predominance. The occurrence of multiple meningiomas is not clear. There are 2 main hypotheses for their development, one that supports the independent evolution of these tumors and the other, completely opposite, that suggests the propagation of tumor cells of a unique clone transformation, through cerebrospinal fluid. NF2 gene mutation is an important intrinsic risk factor in the etiology of multiple meningiomas and some exogenous risk factors have been suspected but only ionizing radiation exposure has been proven. These tumors can grow anywhere in the skull but they are more frequently observed in supratentorial locations. Their histologic types are similar to unique meningiomas of psammomatous, fibroblastic, meningothelial or transitional type and in most cases are benign tumors. The prognosis of these tumors is eventually good and does not differ from the unique tumors except for the cases of radiation-induced multiple meningiomas, in the context of NF2 or when diagnosed in children where the outcome is less favorable. Each meningioma lesion should be dealt with individually and their multiple character should not justify their resection at all costs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Development and validation of LC-MS/MS method with multiple reactions monitoring mode for quantification of vanillin and syringaldehyde in plum brandies

    Directory of Open Access Journals (Sweden)

    Tešević Vele

    2014-01-01

    Full Text Available An ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS method with multiple reactions monitoring mode (MRM has been developed and validated for quantification of vanillin and syringaldehyde in plum brandy. The method showed good linearity (0.05 to 10 mgL−1 and low limits of detection and quantification (LOD and LOQ were 11.6 µgL−1 and 38.2 µgL−1 for vanillin, and 12.7 µgL−1 and 42.0 µgL−1 for syringaldehyde, respectively. The overall intra-day and inter-day variations were less than 4.21%, and the overall recovery over 93.0%. The correlation coefficients (R2 of the calibration curves were higher than 0.9999. In order to evaluate if the method is suitable for use as a routine analytical tool, in 31 Serbian plum brandy samples vanillin and syringaldehide were determined. [Projekat Ministarstva nauke Republike Srbije, br. 172053

  2. Targeted Quantitation of Site-Specific Cysteine Oxidation in Endogenous Proteins Using a Differential Alkylation and Multiple Reaction Monitoring Mass Spectrometry Approach

    Science.gov (United States)

    Held, Jason M.; Danielson, Steven R.; Behring, Jessica B.; Atsriku, Christian; Britton, David J.; Puckett, Rachel L.; Schilling, Birgit; Campisi, Judith; Benz, Christopher C.; Gibson, Bradford W.

    2010-01-01

    Reactive oxygen species (ROS) are both physiological intermediates in cellular signaling and mediators of oxidative stress. The cysteine-specific redox-sensitivity of proteins can shed light on how ROS are regulated and function, but low sensitivity has limited quantification of the redox state of many fundamental cellular regulators in a cellular context. Here we describe a highly sensitive and reproducible oxidation analysis approach (OxMRM) that combines protein purification, differential alkylation with stable isotopes, and multiple reaction monitoring mass spectrometry that can be applied in a targeted manner to virtually any cysteine or protein. Using this approach, we quantified the site-specific cysteine oxidation status of endogenous p53 for the first time and found that Cys182 at the dimerization interface of the DNA binding domain is particularly susceptible to diamide oxidation intracellularly. OxMRM enables analysis of sulfinic and sulfonic acid oxidation levels, which we validate by assessing the oxidation of the catalytic Cys215 of protein tyrosine phosphatase-1B under numerous oxidant conditions. OxMRM also complements unbiased redox proteomics discovery studies as a verification tool through its high sensitivity, accuracy, precision, and throughput. PMID:20233844

  3. Rapid determination of alkaloids in Macleaya cordata using ionic liquid extraction followed by multiple reaction monitoring UPLC-MS/MS analysis.

    Science.gov (United States)

    Li, Linqiu; Huang, Mingyuan; Shao, Junli; Lin, Bokun; Shen, Qing

    2017-02-20

    The ultrasonic-assisted extraction (UAE) and ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) have been successfully applied in extracting of six alkaloids from M. cordata. 1-hexyl-3-methylimidazolium tetrafluoroborate ([C 6 MIM][BF 4 ]) aqueous solution was used as extraction solvent. The target analytes in raw material were deposited into a single drop of 1-hexyl-3-methylimidazolium hexafluorophosphate ([C 6 MIM][PF 6 ]), which was in situ formed by mixing [C 6 MIM][BF 4 ] and potassium hexafluorophosphate ([K][PF 6 ]. Afterwards, the extract was analyzed by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in multiple-reaction monitoring (MRM) mode. The proposed method was fully validated in terms of linearity (0.9983-0.9992), LOD (0.080ngmL -1 ), LOQ (0.25ngmL -1 ), intra-day precision (MS/MS is powerful and practical for analyzing alkaloids in M. cordata., and it also has great potential for comprehensive quality control of other herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    Science.gov (United States)

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  5. Simultaneity, relativity and conventionality

    Science.gov (United States)

    Janis, Allen I.

    2008-01-01

    The view of simultaneity presented by Max Jammer is almost breathtaking, encompassing, as the book's subtitle suggests, the period from antiquity to the 21st century. Many interesting things are to be found along the way. For example, what Jammer (p. 49) says "may well be regarded as probably the earliest recorded example of an operational definition of distant simultaneity" is due to St. Augustine (in his Confessions, written in 397 A.D.; for a modern translation, see Augustine, 2006). He was arguing against astrology by presenting the story of two women, one rich and one poor, who gave birth simultaneously. Although the two children thus had precisely the same horoscopes, their lives followed quite different courses. And how was it determined that the births were simultaneous? A messenger went from each birth site to the other, leaving the instant the child was born (and, presumably, traveling with equal speeds). Since the messengers met at the midpoint between the locations of the two births, the births must have been simultaneous. This is, of course, quite analogous to Albert Einstein's definition of simultaneity (given more than 1500 years later), which will be discussed in Section 2.1.

  6. Mutiple simultaneous event model for radiation carcinogenesis

    International Nuclear Information System (INIS)

    Baum, J.W.

    1979-01-01

    Theoretical Radiobiology and Risk Estimates includes reports on: Multiple Simultaneous Event Model for Radiation Carcinogenesis; Cancer Risk Estimates and Neutron RBE Based on Human Exposures; A Rationale for Nonlinear Dose Response Functions of Power Greater or Less Than One; and Rationale for One Double Event in Model for Radiation Carcinogenesis

  7. Optimal Design of Multitype Groundwater Monitoring Networks Using Easily Accessible Tools.

    Science.gov (United States)

    Wöhling, Thomas; Geiges, Andreas; Nowak, Wolfgang

    2016-11-01

    Monitoring networks are expensive to establish and to maintain. In this paper, we extend an existing data-worth estimation method from the suite of PEST utilities with a global optimization method for optimal sensor placement (called optimal design) in groundwater monitoring networks. Design optimization can include multiple simultaneous sensor locations and multiple sensor types. Both location and sensor type are treated simultaneously as decision variables. Our method combines linear uncertainty quantification and a modified genetic algorithm for discrete multilocation, multitype search. The efficiency of the global optimization is enhanced by an archive of past samples and parallel computing. We demonstrate our methodology for a groundwater monitoring network at the Steinlach experimental site, south-western Germany, which has been established to monitor river-groundwater exchange processes. The target of optimization is the best possible exploration for minimum variance in predicting the mean travel time of the hyporheic exchange. Our results demonstrate that the information gain of monitoring network designs can be explored efficiently and with easily accessible tools prior to taking new field measurements or installing additional measurement points. The proposed methods proved to be efficient and can be applied for model-based optimal design of any type of monitoring network in approximately linear systems. Our key contributions are (1) the use of easy-to-implement tools for an otherwise complex task and (2) yet to consider data-worth interdependencies in simultaneous optimization of multiple sensor locations and sensor types. © 2016, National Ground Water Association.

  8. Simultaneous detection of Legionella species and L. anisa, L. bozemanii, L. longbeachae and L. micdadei using conserved primers and multiple probes in a multiplex real-time PCR assay.

    Science.gov (United States)

    Cross, Kristen E; Mercante, Jeffrey W; Benitez, Alvaro J; Brown, Ellen W; Diaz, Maureen H; Winchell, Jonas M

    2016-07-01

    Legionnaires' disease is a severe respiratory disease that is estimated to cause between 8,000 and 18,000 hospitalizations each year, though the exact burden is unknown due to under-utilization of diagnostic testing. Although Legionella pneumophila is the most common species detected in clinical cases (80-90%), other species have also been reported to cause disease. However, little is known about Legionnaires' disease caused by these non-pneumophila species. We designed a multiplex real-time PCR assay for detection of all Legionella spp. and simultaneous specific identification of four clinically-relevant Legionella species, L. anisa, L. bozemanii, L. longbeachae, and L. micdadei, using 5'-hydrolysis probe real-time PCR. The analytical sensitivity for detection of nucleic acid from each target species was ≤50fg per reaction. We demonstrated the utility of this assay in spiked human sputum specimens. This assay could serve as a tool for understanding the scope and impact of non-pneumophila Legionella species in human disease. Published by Elsevier Inc.

  9. Simultaneous Qualitative and Quantitative Analysis of Multiple Chemical Constituents in YiQiFuMai Injection by Ultra-Fast Liquid Chromatography Coupled with Ion Trap Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Chunhua Liu

    2016-05-01

    Full Text Available YiQiFuMai injection (YQFM is a modern lyophilized powder preparation derived from the traditional Chinese medicine Sheng-mai san (SMS used for treating cardiovascular diseases, such as chronic heart failure. However, its chemical composition has not been fully elucidated, particularly for the preparation derived from Ophiopogon japonicus. This study aimed to establish a systematic and reliable method to quickly and simultaneously analyze the chemical constituents in YQFM by ultra-fast liquid chromatography coupled with ion trap time-of-flight mass spectrometry (UFLC-IT-TOF/MS. Sixty-five compounds in YQFM were tentatively identified by comparison with reference substances or literature data. Furthermore, twenty-one compounds, including three ophiopogonins, fifteen ginsenosides and three lignans were quantified by UFLC-IT-TOF/MS. Notably, this is the first determination of steroidal saponins from O. japonicus in YQFM. The relative standard deviations (RSDs of intra- and inter-day precision, reproducibility and stability were <4.9% and all analytes showed good linearity (R2 ≥ 0.9952 and acceptable recovery of 91.8%–104.2% (RSD ≤ 5.4%, indicating that the methods were reliable. These methods were successfully applied to quantitative analysis of ten batches of YQFM. The developed approach can provide useful and comprehensive information for quality control, further mechanistic studies in vivo and clinical application of YQFM.

  10. The simultaneous boost technique

    International Nuclear Information System (INIS)

    Lebesque, J.V.; Keus, R.B.

    1991-01-01

    Simultaneous boost technique in radiotherapy consists of delivering the boost treatment (additional doses to reduced volumes) simultaneously with the basic (large-field) treatment for all treatment sessions. Both the dose per fraction delivered by basic-treatment fields and by boost-treatment fields have to be reduced to end up with the same total dose in boost volume as in the original schedule, where basic treatment preceded boost treatment. These dose reductions and corresponding weighting factors have been calculated using the linear-quadratic (LQ) model and the concept of Normalized Total Dose (NTD). Relative NTD distributions were computed to evaluate the dose distributions resulting for the simultaneous boost technique with respect to acute and late normal tissue damage and tumor control. For the example of treatment of prostate cancer the weighting factors were calculated on basis of NTD for late normal tissue damage. For treatment of oropharyngeal cancer NTD for acute and normal tissue damage was used to determine the weighting factors. In this last example a theoretical sparing of late normal tissue damage can be demonstrated. Another advantage of simultaneous boost technique is that megavoltage images of the large basic-treatment fields facilitates the determination of the position of the patient with respect to the small boost-treatment fields. (author). 42 refs., 8 figs

  11. Simultaneous orthogonal plane imaging.

    Science.gov (United States)

    Mickevicius, Nikolai J; Paulson, Eric S

    2017-11-01

    Intrafraction motion can result in a smearing of planned external beam radiation therapy dose distributions, resulting in an uncertainty in dose actually deposited in tissue. The purpose of this paper is to present a pulse sequence that is capable of imaging a moving target at a high frame rate in two orthogonal planes simultaneously for MR-guided radiotherapy. By balancing the zero gradient moment on all axes, slices in two orthogonal planes may be spatially encoded simultaneously. The orthogonal slice groups may be acquired with equal or nonequal echo times. A Cartesian spoiled gradient echo simultaneous orthogonal plane imaging (SOPI) sequence was tested in phantom and in vivo. Multiplexed SOPI acquisitions were performed in which two parallel slices were imaged along two orthogonal axes simultaneously. An autocalibrating phase-constrained 2D-SENSE-GRAPPA (generalized autocalibrating partially parallel acquisition) algorithm was implemented to reconstruct the multiplexed data. SOPI images without intraslice motion artifacts were reconstructed at a maximum frame rate of 8.16 Hz. The 2D-SENSE-GRAPPA reconstruction separated the parallel slices aliased along each orthogonal axis. The high spatiotemporal resolution provided by SOPI has the potential to be beneficial for intrafraction motion management during MR-guided radiation therapy or other MRI-guided interventions. Magn Reson Med 78:1700-1710, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Simultaneous Balancing and Model Reduction of Switched Linear Systems

    NARCIS (Netherlands)

    Monshizadeh, Nima; Trentelman, Hendrikus; Camlibel, M.K.

    2011-01-01

    In this paper, first, balanced truncation of linear systems is revisited. Then, simultaneous balancing of multiple linear systems is investigated. Necessary and sufficient conditions are introduced to identify the case where simultaneous balancing is possible. The validity of these conditions is not

  13. Simultaneous neutron and gamma spectrum adjustment

    International Nuclear Information System (INIS)

    Remec, I.

    1996-01-01

    The spectrum adjustment procedure was extended to simultaneous neutron and gamma spectrum adjustment, and the feasibility of this technique is demonstrated in the analysis of HFIR dosimetry experiments. Conditions in which gamma rays may contribute considerably to radiation damage in steels are discussed. Beryllium helium accumulation fluence monitors (HAFMs) were found to be good monitors in gamma fields of intensities high enough to contribute to steel embrittlement. Use of 237 Np, 238 U, and 9 Be HAFM as gamma dosimeters is proposed for high-dose irradiations in high-energy, high-intensity gamma fields

  14. SIMULTANEOUS DIFFERENTIAL EQUATION COMPUTER

    Science.gov (United States)

    Collier, D.M.; Meeks, L.A.; Palmer, J.P.

    1960-05-10

    A description is given for an electronic simulator for a system of simultaneous differential equations, including nonlinear equations. As a specific example, a homogeneous nuclear reactor system including a reactor fluid, heat exchanger, and a steam boiler may be simulated, with the nonlinearity resulting from a consideration of temperature effects taken into account. The simulator includes three operational amplifiers, a multiplier, appropriate potential sources, and interconnecting R-C networks.

  15. Politics Under Electronic Simultaneity

    Directory of Open Access Journals (Sweden)

    Valery P. Terin

    2014-01-01

    Full Text Available In contradistinction to the book and the other typographic products, the electronic media operates on a 24-hour-a-day basis evoking simultaneity as the guiding mode of perception and thinking for all those under its influence. The discovery of this fact manifested itself in the formation and development of the managerial technologies operating by means of the electronic information environment and following the principle of simultaneity in the first place. Thus, at the end of the 1960s already the election campaigns in the U.S.A. began to operate on the basis of the final cause as the guiding principle of the country's mass consciousness motivating to carry out each particular event as if already rejoicing at the victory. With this in mind, there emerged a problem of applying this approach with its enormous managerial potential elsewhere. To add, simultaneity as a norm of perception and thinking turned out to be increasingly important with the advent of the electrical telegraph and the press relying on its short disconnected messages instantaneously arriving from all parts of the world. All the other media, which emerged in the wake of this development, has served to fortify this mode of thought as governing in the electronic information environment. The potential of the electronically operating global managerial technologies is quickly growing. The article also deals with the information overload and pattern recognition problem understood in managerial terms as well as mythologization and demythologization processes as they are necessitated by the electronic media coverage worldwide.

  16. Quantitative changes in proteins responsible for flavonoid and anthocyanin biosynthesis in strawberry fruit at different ripening stages: A targeted quantitative proteomic investigation employing multiple reaction monitoring.

    Science.gov (United States)

    Song, Jun; Du, Lina; Li, Li; Kalt, Wilhelmina; Palmer, Leslie Campbell; Fillmore, Sherry; Zhang, Ying; Zhang, ZhaoQi; Li, XiHong

    2015-06-03

    To better understand the regulation of flavonoid and anthocyanin biosynthesis, a targeted quantitative proteomic investigation employing LC-MS with multiple reaction monitoring was conducted on two strawberry cultivars at three ripening stages. This quantitative proteomic workflow was improved through an OFFGEL electrophoresis to fractionate peptides from total protein digests. A total of 154 peptide transitions from 47 peptides covering 21 proteins and isoforms related to anthocyanin biosynthesis were investigated. The normalized protein abundance, which was measured using isotopically-labeled standards, was significantly changed concurrently with increased anthocyanin content and advanced fruit maturity. The protein abundance of phenylalanine ammonia-lyase; anthocyanidin synthase, chalcone isomerase; flavanone 3-hydroxylase; dihydroflavonol 4-reductase, UDP-glucose:flavonoid-3-O-glucosyltransferase, cytochrome c and cytochrome C oxidase subunit 2, was all significantly increased in fruit of more advanced ripeness. An interaction between cultivar and maturity was also shown with respect to chalcone isomerase. The good correlation between protein abundance and anthocyanin content suggested that a metabolic control point may exist for anthocyanin biosynthesis. This research provides insights into the process of anthocyanin formation in strawberry fruit at the level of protein concentration and reveals possible candidates in the regulation of anthocyanin formation during fruit ripening. To gain insight into the molecular mechanisms contributing to flavonoids and anthocyanin biosynthesis and regulation of strawberry fruit during ripening is challenging due to limited molecular biology tools and established hypothesis. Our targeted proteomic approach employing LC-MS/MS analysis and MRM technique to quantify proteins in relation to flavonoids and anthocyanin biosynthesis and regulation in strawberry fruit during fruit ripening is novel. The identification of peptides

  17. Monitor inspection device

    International Nuclear Information System (INIS)

    Ueshima, Yoshinobu.

    1995-01-01

    The device of the present invention reliably conducts monitoring by radiation monitors in a nuclear power plant thereby contributing to save the number of radiation operators and reduction of radiation exposure. Namely, radiation monitors continuously measure a plurality of γ-ray levels. A branched simultaneously counting circuit receives these signals. The output of the branched simultaneously counting circuit is inputted to a differentiation means. The differentiation means calculates a variation coefficient for each of the radiation monitoring values, namely, equivalent dose rates, and records and monitors change with time of the equivalent dose rates. With such procedures, the results of the monitoring of γ-ray levels can be judged objectively corresponding to the increase of the equivalent dose rates. As a result, the number of radiation operators can be saves and radiation exposure of the radiation operators can be reduced. (I.S.)

  18. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine.

    Science.gov (United States)

    Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello

    2018-05-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Detection of multiple tumor markers using ultra-long carbon nanotube devices

    Science.gov (United States)

    So, Hye-Mi; Park, Dong-Won; Kim, Beom Soo; Kong, Ki-Jeong; Buh, Gyoung-Ho; Chang, Hyunju; Lee, Jeong-O.; Kong, Jing

    2008-03-01

    For the simultaneous detection of multiple tumor markers, we have fabricated ultra-long carbon nanotube sensors that can detect carcinoembryonic antigen (CEA) and prostate specific antigen (PSA), simultaneously. Ultra-long carbon nanotubes, several millimeters long, were grown by ethanol CVD, and fabricated as FET sensors by using conventional photolithography. To functionalize each segment of a single ultra-long nanotube device with multiple-tumor markers, we first functionalize the entire device with CDI-Tween 20 linking molecules, and then immobilized CEA and PSA antibodies using the microfluidic channel. The electrical conductance from CEA-antibody functionalized and PSA-antibody functionalized segment of a ultra-long carbon nanotube device was monitored simultaneously with Ag/AgCl reference electrode as a liquid gate. We will discuss the advantages of long-nanotube device in detail.

  20. Better dual-task processing in simultaneous interpreters

    Science.gov (United States)

    Strobach, Tilo; Becker, Maxi; Schubert, Torsten; Kühn, Simone

    2015-01-01

    Simultaneous interpreting (SI) is a highly complex activity and requires the performance and coordination of multiple, simultaneous tasks: analysis and understanding of the discourse in a first language, reformulating linguistic material, storing of intermediate processing steps, and language production in a second language among others. It is, however, an open issue whether persons with experience in SI possess superior skills in coordination of multiple tasks and whether they are able to transfer these skills to lab-based dual-task situations. Within the present study, we set out to explore whether interpreting experience is associated with related higher-order executive functioning in the context of dual-task situations of the Psychological Refractory Period (PRP) type. In this PRP situation, we found faster reactions times in participants with experience in simultaneous interpretation in contrast to control participants without such experience. Thus, simultaneous interpreters possess superior skills in coordination of multiple tasks in lab-based dual-task situations. PMID:26528232

  1. Discrete event simulation: Modeling simultaneous complications and outcomes

    NARCIS (Netherlands)

    Quik, E.H.; Feenstra, T.L.; Krabbe, P.F.M.

    2012-01-01

    OBJECTIVES: To present an effective and elegant model approach to deal with specific characteristics of complex modeling. METHODS: A discrete event simulation (DES) model with multiple complications and multiple outcomes that each can occur simultaneously was developed. In this DES model parameters,

  2. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    Science.gov (United States)

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  3. Simultaneous alcohol and cannabis expectancies predict simultaneous use

    Directory of Open Access Journals (Sweden)

    Earleywine Mitch

    2006-10-01

    Full Text Available Abstract Background Simultaneous use of alcohol and cannabis predicts increased negative consequences for users beyond individual or even concurrent use of the two drugs. Given the widespread use of the drugs and common simultaneous consumption, problems unique to simultaneous use may bear important implications for many substance users. Cognitive expectancies offer a template for future drug use behavior based on previous drug experiences, accurately predicting future use and problems. Studies reveal similar mechanisms underlying both alcohol and cannabis expectancies, but little research examines simultaneous expectancies for alcohol and cannabis use. Whereas research has demonstrated unique outcomes associated with simultaneous alcohol and cannabis use, this study hypothesized that unique cognitive expectancies may underlie simultaneous alcohol and cannabis use. Results: This study examined a sample of 2600 (66% male; 34% female Internet survey respondents solicited through advertisements with online cannabis-related organizations. The study employed known measures of drug use and expectancies, as well as a new measure of simultaneous drug use expectancies. Expectancies for simultaneous use of alcohol and cannabis predicted simultaneous use over and above expectancies for each drug individually. Discussion Simultaneous expectancies may provide meaningful information not available with individual drug expectancies. These findings bear potential implications on the assessment and treatment of substance abuse problems, as well as researcher conceptualizations of drug expectancies. Policies directing the treatment of substance abuse and its funding ought to give unique consideration to simultaneous drug use and its cognitive underlying factors.

  4. Note on Magnetism and Simultaneity

    Science.gov (United States)

    Huggins, Elisha

    2009-01-01

    The paper on "Magnetism and Simultaneity" by Adler provides an excellent new thought experiment involving the lack of simultaneity in Einstein's special relativity. Adler uses the lack of simultaneity rather than the Lorentz contraction to derive the formula for the magnetic force on a moving charged particle. Advantages of his derivation are that…

  5. Application of process monitoring to anomaly detection in nuclear material processing systems via system-centric event interpretation of data from multiple sensors of varying reliability

    International Nuclear Information System (INIS)

    Garcia, Humberto E.; Simpson, Michael F.; Lin, Wen-Chiao; Carlson, Reed B.; Yoo, Tae-Sic

    2017-01-01

    Highlights: • Process monitoring can strengthen nuclear safeguards and material accountancy. • Assessment is conducted at a system-centric level to improve safeguards effectiveness. • Anomaly detection is improved by integrating process and operation relationships. • Decision making is benefited from using sensor and event sequence information. • Formal framework enables optimization of sensor and data processing resources. - Abstract: In this paper, we apply an advanced safeguards approach and associated methods for process monitoring to a hypothetical nuclear material processing system. The assessment regarding the state of the processing facility is conducted at a system-centric level formulated in a hybrid framework. This utilizes architecture for integrating both time- and event-driven data and analysis for decision making. While the time-driven layers of the proposed architecture encompass more traditional process monitoring methods based on time series data and analysis, the event-driven layers encompass operation monitoring methods based on discrete event data and analysis. By integrating process- and operation-related information and methodologies within a unified framework, the task of anomaly detection is greatly improved. This is because decision-making can benefit from not only known time-series relationships among measured signals but also from known event sequence relationships among generated events. This available knowledge at both time series and discrete event layers can then be effectively used to synthesize observation solutions that optimally balance sensor and data processing requirements. The application of the proposed approach is then implemented on an illustrative monitored system based on pyroprocessing and results are discussed.

  6. Simultaneous seeing measurements at Atacama

    Science.gov (United States)

    Uraguchi, Fumihiro; Motohara, Kentaro; Doi, Mamoru; Takato, Naruhisa; Miyashita, Akihiko; Tanabe, Toshihiko; Oyabu, Shinki; Soyano, Takao

    2004-10-01

    Institute of Astronomy, University of Tokyo is now planning to build a 6.5-m optical-infrared telescope in Atacama, Chile. This project is called "Univ. Tokyo Atacama Observatory (TAO)", and the site evaluation is now under way. As a part of this evaluation process, we started an investigation to compare the astronomical seeing at Atacama with that at Mauna Kea. Here, we report preliminary results of seeing measurements at several sites in Atacama, carried out on October 2003. In order to separate the temporal and site-to-site variation of the seeing, we used two sets of Differential Image Motion Monitors (DIMMs), each of which has two pairs of 7.4 cm sub-apertures with 20.5 cm separation. Three sites were investigated; the point near the TAO weather station (4,950m), the summit of Cello Chico (5,150m) and the point at 5,430m altitude on Cello Toco. Simultaneous measurements were carried out for three half nights out of four half nights measurements. Although the amount of our data is very limited, the results suggest following: 1) Seeing becomes better and more stable as time passing to midnight (eg. From 0."7 to 0."4 at V-band). 2) Higher altitude sites show better seeing than lower altitude sites.

  7. BPA genetic monitoring - BPA Genetic Monitoring Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Initiated in 1989, this study monitors genetic changes associated with hatchery propagation in multiple Snake River sub-basins for Chinook salmon and steelhead. We...

  8. Individual identification of free hole and electron dynamics in CuIn{sub 1−x}Ga{sub x}Se{sub 2} thin films by simultaneous monitoring of two optical transitions

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Makoto [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Hagiya, Hideki; Sakurai, Takeaki; Akimoto, Katsuhiro [Institute of Applied Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Shibata, Hajime; Niki, Shigeru [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Kanemitsu, Yoshihiko, E-mail: kanemitu@scl.kyoto-u.ac.jp [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Japan Science and Technology Agency, CREST, Kyoto University, Uji, Kyoto 611-0011 (Japan)

    2015-05-04

    The photocarrier dynamics of CuIn{sub 1−x}Ga{sub x}Se{sub 2} (CIGS) thin films were studied using white-light transient absorption (TA) measurements, as an understanding of this behavior is essential for improving the performance of solar cells composed of CIGS thin films. A characteristic double-peak structure due to the splitting of the valence bands in the CIGS was observed in the TA spectra under near-band-gap resonant excitation. From a comparison of the TA decay dynamics monitored at these two peaks, it was found that the slow-decay components of the electron and hole relaxation are on the nanosecond timescale. This finding is clear evidence of the long lifetimes of free photocarriers in polycrystalline CIGS thin films.

  9. Quantitative profiling of PE, MMPE, DMPE, and PC lipid species by multiple precursor ion scanning: A tool for monitoring PE metabolism

    DEFF Research Database (Denmark)

    Bilgin, Mesut; Markgraf, Daniel F; Duchoslav, Eva

    2011-01-01

    We report a method for the simultaneous identification and quantification of phosphatidylethanolamine (PE), monomethyl-phosphatidylethanolamine (MMPE), dimethyl-phosphatidylethanolamine (DMPE), and phosphatidylcholine (PC) species in lipid extracts. The method employs a specific "mass-tag" strategy...... where DMPE, MMPE, and PE species are chemically methylated with deuterated methyliodide (CD(3)I) to produce PC molecules having class-specific mass offsets of 3, 6 and 9Da, respectively. The derivatized aminoglycerophospholipids release characteristic phosphorylcholine-like fragment ions having specific...... and DMPE, and abundant PE and PC species in a single mass spectrometric analysis. We demonstrated the efficacy of the methodology by conducting a series of biochemical experiments using stable isotope labeled ethanolamine to survey the activities and substrate specificities of enzymes involved in PE...

  10. Multiple-targeted graphene-based nanocarrier for intracellular imaging of mRNAs

    International Nuclear Information System (INIS)

    Wang, Ying; Li, Zhaohui; Liu, Misha; Xu, Jinjin; Hu, Dehong; Lin, Yuehe; Li, Jinghong

    2017-01-01

    Simultaneous detection and imaging of multiple intracellular messenger RNA (mRNAs) hold great significant for early cancer diagnostics and preventive medicine development. Herein, we propose a multiple-targeted graphene oxide (GO) nanocarrier that can simultaneously detect and image different type mRNAs in living cells. First of all, in vitro detection of multiple targets have been realized successfully based on the multiple-targeted GO nanocarrier with linear relationship ranging from 3 nM to 200 nM, as well as sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) mRNA and 2.45 nM for β-actin mRNA. Additionally, this nanosensing platform composed of fluorescent labelled single strand DNA probes and GO nanocarrier can identify Mn-SOD mRNA and endogenous mRNA of β-actin in living cancer cells, showing rapid response, high specificity, nuclease stability, and good biocompatibility during the cell imaging. Thirdly, changes of the expression levels of mRNA in living cells before or after the drug treatment can be monitored successfully. By using multiple ssDNA as probes and GO nanocarrier as the cellular delivery cargo, the proposed simultaneous multiple-targeted sensing platform will be of great potential as a powerful tool for intracellular trafficking process from basic research to clinical diagnosis. - Graphical abstract: Schematic illustration of simultaneously multiple mRNAs monitoring inside single living breast cancer cell based on GO nanocarrier. In particular, the fluorescent signals could be monitored when Mn-SOD probe (red) and β-actin probe (green) hybridizes with their mRNA targets inside the living cells. Random probe (orange) was regarded as control probe for the sensing strategy. - Highlights: • A multiple-targeted GO nanocarrier was used for mRNAs imaging and expression changes after drug treatment can be monitored successfully. • Sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) m

  11. Simultaneous identification of abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hei-Hwa Lee

    2016-03-01

    Full Text Available A literature search reveals no studies concerning simultaneous identification of commonly abused drugs, benzodiazepines, and new psychoactive substances in urine by liquid chromatography tandem mass spectrometry (LC–MS/MS. We developed and validated an LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine from suspected drug abusers. The instrument was operated in multiple-reaction monitoring using an electrospray ionization mode. Chromatograms were separated using an ACE5 C18 column on a gradient of acetonitrile. After liquid–liquid extraction, samples were passed through a 0.22-μm polyvinylidene difluoride filter before injection into the LC–MS/MS. The limits of quantitation ranged from 0.5 ng/mL to 31.3 ng/mL. The linearity ranged from 0.5 ng/mL to 200 ng/mL. The precision results were below 15.4% (intraday and 18.7% (interday. The intraday accuracy ranged from 85.9% to 121.0%; interday accuracy ranged from 66.1% to 128.7%. The proposed method was applied to 769 urine samples. The most common three drugs identified were ketamine, amphetamine, and opiates. The drug positive rate for one or more drugs was 79.6%. Our results demonstrate the suitability of the LC–MS/MS method for simultaneous identification of multiple abused drugs, benzodiazepines, and new psychoactive substances in urine.

  12. Development of a generic system for real-time data access and remote control of multiple in-situ water quality monitoring instruments

    Science.gov (United States)

    Wright, S. A.; Bennett, G. E.; Andrews, T.; Melis, T. S.; Topping, D. J.

    2005-05-01

    Currently, in-situ monitoring of water quality parameters (e.g. water temperature, conductivity, turbidity) in the Colorado River ecosystem typically consists of deploying instruments in the river, retrieving them at a later date, downloading the datalogger, then examining the data; an arduous process in the remote settings of Grand Canyon. Under this protocol, data is not available real-time and there is no way to detect problems with the instrumentation until after retrieval. The next obvious stage in the development of in-situ monitoring in Grand Canyon was the advent of one-way telemetry, i.e. streaming data in real-time from the instrument to the office and/or the world-wide-web. This protocol allows for real-time access to data and the identification of instrumentation problems, but still requires a site visit to address instrument malfunctions, i.e. the user does not have the ability to remotely control the instrument. At some field sites, such as the Colorado River in Grand Canyon, site visitation is restricted by remoteness and lack of traditional access routes (i.e. roads). Even at less remote sites, it may still be desirable to have two-way communication with instruments in order to, for example, diagnose and potentially fix instrumentation problems, change sampling parameters to save battery power, etc., without having to visit the site. To this end, the U.S. Geological Survey, Grand Canyon Monitoring and Research Center, is currently developing and testing a high-speed, two-way communication system that allows for real-time data access and remote control of instrumentation. The approach tested relies on internet access and may be especially useful in areas where land-line or cellular connections are unavailable. The system is composed of off-the-shelf products, uses a commercial broadband satellite service, and is designed in a generic way such that any instrument that communicates through RS-232 communication (i.e. a serial port) is compatible with

  13. Multiple-Targeted Graphene-based Nanocarrier for Intracellular Imaging of mRNAs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ying; Li, Zhaohui; Liu, Misha; Hu, Dehong; Lin, Yuehe; Li, Jinghong

    2017-08-29

    Simultaneous detection and imaging of multiple intracellular messenger RNA (mRNAs) hold great significant for early cancer diagnostics and preventive medicine development. Herein, we propose a multiple-targeted graphene oxide (GO) nanocarrier that can simultaneously detect and image different type mRNAs in living cells. First of all, in vitro detection of multiple targets have been realized successfully based on the multiple-targeted GO nanocarrier with linear relationship ranging from 3 nM to 200 nM, as well as sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) mRNA and 2.45 nM for β-actin mRNA. Additionally, this nanosensing platform composed of fluorescent labeled single strand DNA probes and GO nanocarrier can identify Mn-SOD mRNA and endogenous mRNA of β-actin in living cancer cells, showing rapid response, high specificity, nuclease stability, and good biocompatibility during the cell imaging. Thirdly, changes of the expression levels of mRNA in living cells before or after the drug treatment can be monitored successfully. By using multiple ssDNA as probes and GO nanocarrier as the cellular delivery cargo, the proposed simultaneous multiple-targeted sensing platform will be of great potential as a powerful tool for intracellular trafficking process from basic research to clinical diagnosis.

  14. Optimal Measurements for Simultaneous Quantum Estimation of Multiple Phases.

    Science.gov (United States)

    Pezzè, Luca; Ciampini, Mario A; Spagnolo, Nicolò; Humphreys, Peter C; Datta, Animesh; Walmsley, Ian A; Barbieri, Marco; Sciarrino, Fabio; Smerzi, Augusto

    2017-09-29

    A quantum theory of multiphase estimation is crucial for quantum-enhanced sensing and imaging and may link quantum metrology to more complex quantum computation and communication protocols. In this Letter, we tackle one of the key difficulties of multiphase estimation: obtaining a measurement which saturates the fundamental sensitivity bounds. We derive necessary and sufficient conditions for project